12. NOTES. SC-20 TEMPERATURE CONTROLLER. 2.0 version
|
|
- Derick Gregory
- 6 years ago
- Views:
Transcription
1 2. NOTES. SC2 TEPERATURE CONTROLLER 2. version 2
2 . SPECIFICATIONS Input: easuring range: easuring accuracy: ±,5% Sampling period: Display resolution: Setting resolution: Display: Control form: Protection class: : Operating conditions: Storage conditions: Output: Relay: 3A 25V~ 5 cycles two temperature sensors: NTC 5k by 25 bistate input (normally opened or normally closed) 33 ms, in whole range, in whole range LED, 4 digits, mm height with graphic icons ONOFF with hysteresis IP65 / II 2. OUTPUTS CARRYING CAPACITY. OUTPUT OUTPU. 8A 25V~ 5 cycles 23V~ ±5% or 24V~ or 2V=/~, max 3VA 5...6;...85%RH (noncondensing) ;...85%RH (noncondensing) aximum resistive load (for example heater): aximum inductive load (for example engine): 2A, 45W 8A, 5W, 2HP(2K) 8A, 5W 2A, 4W,.5HP(.5K).2. Domestic hot water circuit circulation and central heating circuit co Boiler Pch Pdhw Cold water domestic hot water circulating and central heating control system. F= (container T and boiler temp measurement) F=ting specifying the boiler temperature growth in relation to the container temperature so that the domestic hot water switches on, for example 8 F2=DHW switching hysteresis, for example. 2 C F5=given water temperature in the container. DHW has a priority, so that only after reaching this ting, central heating switches on, for example 6 F6=OFF; F7=.; F2=; F29=COOL ; F5= ; F5= F52= (when central heating switches on, domestic hot water switches off) T SC2 Pdhw 2(8)A Pch T D.H.W container temperature sensor. temperature sensor on the of the boiler DHW and CH max. 4W 23V~ F 8 6 ain T when T>F5 23V~ F2=2 F2=2 3. FRONT PANEL. temperature display temperature sensor number entry to the parameters menu temperature ting button value increasing button value decreasing button temperature ting signalling OUTPUT signalling. LIGHTS: active; BLINKS: waits for startup OUTPU signalling. LIGHTS: min or max temperature value exceeded (see: F5 or F6); BLINKS: waits for startup (see: F7) emergency states signalling 2
3 . ADVANCED SYSTES... Solar collector and boiler circulating control system. 4. CONTROLLER HANDLING. 4.. TEPERATURE SETTING. T Pkt SC2 2(8)A Pk Pkt Push the button for 2 seconds. Diode lights up. Using or button the desired temperature value. Pk collector control central heating boiler circulating control system F= (boiler T and collector temp. measurement) F=temperature difference T between the solar collector and the boiler after reaching that, the collector's switches on, for example 8 F2= switching hysteresis, for example 2 C F5=OFF F6=In cloudy days, when solar energy is low, it is essential to heatup the boiler from the other source. This parameter specifies the boiler temperature below which an external heating source switches on, for example boiler circulating. Setting, for example 4. F7=9min (external heating source switching delay) F2=; F29=COOL ; F5= ; F5= ; F52= T boiler temperature sensor collector temperature sensor Collector and boiler max. 4W 23V~ 8 F 6 ain T When T<F6 23V~ F2=2 F2=2 Confirm the with Key. Diode lights off. Remarks: to cancel the ting, press the button in any time the ting change can be limited by F3 and F4 parameters Information: To improve quick increasing or decreasing the tings values hold the or button constantly for at least sec PARAETERS PROGRAING. Enter the menu holding Key for 5 sec., Until: Command displays. If the access is protected Command displays. Using, and Buttons enter the password and confirm with key. Using or key choose the parameter you want to change and enter with Key. Using or button the desired parameter value. Using key confirm the new parameter value and return to the parameters list. Remarks: press button to cancel the parameter ting Finish programming pressing button or enter the End command and press key or wait 3 sec. without pressing any button Information: Hold or button for at least sec. to improve quick increasing and decreasing of ting values. 3
4 4.3. DESCRIPTION OF THE PARAETERS. Code: Description: Range: Default: F Controller work mode: normal (displays from the main sensor T, auxiliary sensor off) differential (display difference between auxiliary and main sensor (T),, 2 2 average (display average from two sensors: main and auxiliary (T+/2) F Value of tempereture ting. Range of changes is limited by F4 and F3. F4...F3 8. F2 Hysteresis (temperature control accuracy) F3 aximum value possible to by the user F4 inimum value possible to by the user F5 High temperature alarm. F5=OFF alarm off F6 Low temperature alarm. F6=OFF alarm off F7 The delay of switching high and low temperature min.min F8 Temperature sensor calibration. This is the value of rescaling the temperature sensor in relation to actually measured temperature F9 Temperature sensor T calibration. This is the value of rescaling the T temperature sensor in relation to actually measured temperature F2 Output minimum down time. It also means the delay time of switching the on after giving power supply. Parameter protects devices,...min.min for example engine from too frequent switching in case of power failure. F29 Controlling work mode: COOLING/HEATING COOL/HEAT COOL F5 Digital input D: unused; alarm when circuit 45 closed, 2 alarm when circuit 45 closed with maintaince of alarm signalling, 3 alarm when circuit 45 opened, alarm when circuit 45 opened with maintance of alarm signalling F5 Sound signaller (beep) active when temperature alarm: N, YES, F52 The way of protection the system and the devices connected to the main when the temperature alarm occurs: main off and locked when an alarm, main on and locked when the alarm, 2 alarm does not affect the operation of the main,, 2 F57 Output2 contacts scheme: contacts normally opened, closed when the temperature alarm or when digital input activation; contacts normally closed, opened when the temperature alarm or when digital input activation, F8 Password to access the configuration menu. OFF password protection inactive, F8 = no password OFF F83 Display mode measurement from two sensors displayed alternately every 3 sec.; measurement from T sensor; 2 measurement from sensor,, 2 F98 Reserved. F99 Controller test. Disconnect device to make the test! Otherwise the system can crash. End Exit the menu. 5. GENERAL DESCRIPTION. 5.. ADJUSTENT. SC2 is designed to control the heating and cooling system. A wide range of configuration makes the controller perfect for use in typical arrangements, such as boiler or circulating Control and complex, for example: solar collector or fireplace with water jacket control. Adjustment is based on the measurement from one or two temperature sensors: when measuring from one sensor (F=) controller mainstains the temperature switching on the main in ''heating'' or ''cooling'' mode with deviation (regulated hysteresis) when measuring from two sensors the user can select the operating mode of the controller: the is activated based on the difference (F=) or average (F=2) from two temperature sensors. In differential mode, the controller activates, for example collector circulating after reaching an essential difference between boiler's and collector's sensor. And in averaging mode, the controller operates as an usual temperature controller except that the measured value is calculated from the arithmetic average of readings from two temperature sensors, for example at the two ends of the pipeline or the boiler OUTING. Controller should be placed in the panel in hole sized 7x29mm and fasten with mounting terminals. Ip65 protection class 6 5 Ip67 protection class 9. INSTALLATION. outing terminals Panel surface (maximum thickness 2mm) 2 2 max 2 Be aware of the conditions where the controller operates. Install in a place, where there is not too high temperature and humidity and no condensation. Should be ventilated in order to remove the heat. ATTENTION! It is not allowed to work with electric cables when the device is energized. You should avoid crossing wires using short connections. We recommend securing the source of controller power supply and temperature sensor input against electrical interference. AD ISSIONS. Controller meets the requirements for immunity to electromagnetic interference in an industrial environment according to the following standards: Electromagnetic compatibility (EC): EN6 part 64 requirements for emissivity in an industrial environment EN6 part 62 requirements for immunity in an industrial environment It also meets the safety requirements according to standard: EN6 part safety requirements for eletrical devices Controller meets the requirements of EU directives No. 72/23/EEC; 93/68/EEC; 89/336EEC. 4,
5 5.7. Chamber, incubator and boiler with adjustment calculated from the arithmetic mean of the measurements from two temperature sensors T and T PRECISE control system. 2(8)A SC2 Here are some examples of control systems using the SC2 including diagrams of supported installations, tips for programming and diagrams of electric connections with external alarm control system. SC2 2(8)A BOILER Electric heater Thermostat ~23V heater control system protection against overheating and freezing emergency states sound signalling F = 2 (temperature measurement from two sensors T and ) F = temperature ting F2 = heater switching hysteresis, for example F5 = high temperature alarm, for example 85 F6 = low temperature alarm, for example 5 F7 =.; F2 = ; F29 = HEATING; F5 = ; F5 = ; F52 = 6. DIGITAL INPUT. T T boiler temperature sensor fireplace temperature sensor max. 32W, signaller 23V~ 8 F 8 79 ain T+ 2 23V~ F2= F2= F6 Controller has digital input D for emergency states signalling, such as system failure, pressure control or safety thermostat activation, etc. Input type (normally opened, normally closed) is programmed by F5 parameter. After opening/closing circuit of 45 digital input, the controller turns off the main and turns on the sound signaller (beep) and an auxiliary and the display shows A code. Emergency state sound signalling can be maintained, until the alarm re by using the buttons (F5=2 or 4). 7. ALAR ESSAGES. When alarm activates the indicator starts to blink and the sound signaller (beep) activates (when F83=). According to the occurence controller turns on/off and the front panel displays one of the following alarm messages: 8 Statement Occurence digital input activation F5 T sensor error: open circuit or short circuit sensor error: open circuit or short circuit high temperature alarm F5 low temperature alarm F Output operation auxiliary active, the main inactive auxiliary active, the main inactive auxiliary active, the main inactive F5 auxiliary active, the main depends on the ting of F52 auxiliary active, the main depends on the ting of F52 T heater control (boiler, electric heater, etc.) system protection against overheating and freezing emergency states sound signalling F = (system temp. measurement from T sensor) F = temperature ting F2 = heater switching hysteresis, for example F5 = high temperature alarm, for example 85 F6 = low temperature alarm, for example 5 F7 =.; F2=; F29=HEATING F5 = or 2 (2 if you used the external safety thermostat connected to the D input) F5 = (sound signaller active) F52 = (heater off in danger point) 5.3. and fan control system. T Fan heater heating up the chamber control fan cooling the chamber control emergency states sound signalling F = (temperature measurement from T sensor) F = temperature ting F2 = heater switching hysteresis, for example F5 = temperature ting of switching the fan cooling the chamber, for example 3 F6 = OFF F7 =.; F2 = F29 = HEATING F5 = or 2 (2 if you used the external safety thermostat connected to the D input) F5 = ; F52 = T main temperature sensor D external safety thermostat max. 32W, signaller 23V~ 85 8 F ain SC2 2 F 2 9 ain Thermostat 2(8)A Fan T main temperature sensor D external safety thermostat max. 32W, wentylator 4W 23V~ 23V~ F5 F2= F2= F6 23V~ 3 F5 F2= F2= czas
6 5.3. Central heating circuit circulating with an external alarm control system Solar collector with an external alarm control system. SC2 2(8)A SC2 2(8)A T Central heating Thermostat T Fireplace Central T main temperature sensor heating Boiler D external safety thermostat Zasilanie Central heating and signaller max. 4W 23V~ 23V~ central heating circulating control 85 F5 system protection against overheating 4 F±F2 F= (T pipeline temperature measurement) F= start temperature ting, for example 4 F2= switching hysteresis, for example. F5=high temperature alarm in boiler, for example 85 ain F6=OFF; F =.; F2 = F29=COOLING (switching after reaching the temperature of the boiler) F5= or 2 (2 if you used an external safety thermostat connected to the D input) F5= (sound signaller active) F52= (when the high temperature alarm occurs, the switches on to cool down the water in the boiler) 5.4. Domestic hot water circuit circulating with an external alarm control system. SC2 2(8)A Cp collector control boiler protection against overheating F= (boiler T and collector temperature measurement) F=temperature difference T between the solar collector and the boiler after reaching that, the collector's switches on, for example 8 F2= switching hysteresis, for example 2 F5=boiler overheating alarm, for example 85 F6=OFF; F7 =.; F2 =, F29 = COOL; F5 = F5= (sound signaller active) F52= (when the boiler overheating alarm occurs, is turned off so as not to collect a hot factor from the collector) 5.6. Fireplace with water jacket control system. T boiler temperature sensor collector temperature sensor Collector (Cp) and signaller max. 4W 23V~ 23V~ F 8 6 ain SC2 2(8)A T When T>F5 F2=2 F2=2 T Domestic hot Thermostat water FIREPLACE T Central heating Fireplace Central heating D.h.w. Pump Boiler Cold water domestic hot water circulating control system protection against overheating F = (T boiler temperature measurement) F = boiler temperature ting, for example 6 F2 = switching hysteresis, for example. F5 = high temperature alarm, for example 85 F6 = OFF; F7 =.; F2 = F29 = HEATING ( works until the temperature is reached) F5 = or 2 (2 if you used an external safety thermostat connected to the D input) F5 = (sound signaller active) F52 = (when high temperature alarm occurs, the s is switched on) T main temperature sensor D external safety thermostat D.h.w. and signaller max. 4W 23V~ 85 6 ain 23V~ F5 F±F2 Collector Cold water fireplace control central heating circulating control. F= (boiler T and fireplace temp. measurement) F=ting specifying the fireplace temperature growth in relation to the boiler temperature so that the fireplace switches on, for example 8 F2=fireplace switching hysteresis, for example 2 F5= water temperature in the boiler. Loading the domestic hot water boiler using the fireplace is a priority, so that only after reaching this ting, the central heating switches on, for example 6 F6=OFF; F7=.; F2=; F29=COOL; F5=; F5= F52 = (when the central heating switches on, fireplace is switched off) T boiler temperature sensor fireplace temperature sensor Collector and c.h. max. 4W 23V~ 8 F 6 ain T When T<F6 23V~ F2=2 F2=2
Electronic Pellet Burner Controller NPBC-V3-1
Electronic Pellet Burner Controller NPBC-V3- SOFTWARE VERSION 3.2/3. page of 3 CHANGES IN THE TECHNICAL AND USER GUIDE OR IN THE SOFTWARE VERSION Technical and User Guide's version Changes Page 2.8. The
More informationWeekly thermostat for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW Users guide.
Weekly thermostat for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW Users guide. SHORT DESCRIPTION: 1. Device is applicable to: - Burners; - Electric boiler;
More informationST 53.1 User s manual
Tech - 1 - ST 53.1 User s manual Table of contents I. Safety... 3 II. Description... 4 III. Installation... 4 IV. Operating the Controller... 6 IV.a) Principle of Operation... 6 IV.b) Control... 6 V. Controller
More informationInstallation and Operating Manual
Installation and Operating Manual SR868C6 System Regulator for Solar Thermal Systems Display Panel Illustration Pos. Button on display panel Button description 1 Green lamp Power indication lamp 2 On/Off
More informationSOLARCOMP 951 CONTROLLER FOR SOLAR COLLECTORS
SOLARCOMP 951 CONTROLLER FOR SOLAR COLLECTORS Installation and Operating Instructions for model u7.x, Rev. 1, April 2014 Pb Safety Instructions Before installation read these Operation and Installation
More informationContent. Ⅰ General information 1. Ⅱ Product description 2. Ⅲ System description 3. Ⅳ Fault message 9. Packing list 9
Content Ⅰ General information 1 Ⅱ Product description 2 Ⅲ System description 3 Ⅳ Fault message 9 Ⅴ Packing list 9 Appendix: Network Connection Manual 1 About this manual This manual book describes the
More informationENVI Boiler Controller
GSG Rev. 0.0 6/2/2009 ENVI Boiler Controller Getting Started Guide Installation Date: Harsco Industrial, Patterson-Kelley 100 Burson Street East Stroudsburg, PA 18301 Telephone: (877) 728-5351 Facsimile:
More informationElectronic Pellet Burner Controller NPBC-V3M
Electronic Pellet Burner Controller NPBC-V3M SOFTWARE VERSION 3.3a/3.2 page of 27 CHANGES IN THE USER MANUAL OR IN THE CONTROLLER'S SOFTWARE Version of the user manual Changes Page 2.2. The software version
More informationController PCSol 300 FOR SOLAR COLLECTORS. INSTALLATION AND OPERATION MANUAL 62.X.2 REVISION SOFTWARE
Controller PCSol 300 FOR SOLAR COLLECTORS www.econet24.com PUMP PUMP CIRCULATION PUMP ROTATION CONTROL CIRCULATION PROGRAM HEATER SUPPORT HEATER PROGRAM SIMPLE IN USE INTELLIGENT ALARM CLOCK 10 DAYS CLOCK
More informationWH7016E Thermostat Product Manual
WH7016E Thermostat Product Manual Shenzhen Willhi Electronics Co., Ltd. Tel :0755-29539385 Fax :86-0755 -2953 9395 Technical support: Engineer Tian 1 Installation opening size: 2 Wiring diagram: 1 2 3L
More informationMounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller
TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller Mounting and Operating Instructions Electronics from SAMSON EB 5610 EN Firmware version 1.40 Edition December 2014 Controller
More informationDeclaration of Conformity no. 56/2012
tech -1- ST 280 Instructions manual Declaration of Conformity no. 56/2012 We, TECH Sp.j., with our registered company office at Wieprz 1047A, 34-122 Wieprz, Poland declare under our full responsibility
More informationDixell Installing and Operating Instructions release 7.0
XR160C - XR160D - XR170C - XR170D - XR162C - XR172C CONTENTS 1. GENERAL WARNING 2 1.1 Please read before using this manual 2 1.2 Safety Precautions 2 2. GENERAL DESCRIPTION 2 3. CONTROLLING LOADS 2 3.1
More informationInstaller Manual KNX Touchscreen Thermostat
Installer Manual 02952 KNX Touchscreen Thermostat Index GENERAL FEATURES AND FUNCTIONALITY from page 5 ETS PARAMETERS AND COMMUNICATION OBJECTS from page 7 COMMUNICATION OBJECTS GENERAL FEATURES AND FUNCTIONALITY
More informationFloor heating controls, wire connection 1
Floor heating controls, wire connection 1 Contents: Introduction UFH-ZONE-W UFH-EXTRAZONE-W Connection of a thermostat (UFH-THERM-W) o Joining of a thermostat with UFH-ZONE-W or UFH-EXTRAZONE-W Connection
More informationVersion 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2
Version 1.6 Operating instructions HYDROETTE BL COPACT TF 2 EN 1 Table of contents 0.1 Publication statement... 3 0.2 General notes... 4 0.3 WEEE directive 2002/96/EC law on electrical and electronic equipment...
More informationUSER GUIDE Heat Index Psychrometer
USER GUIDE Heat Index Psychrometer Model RH25 Introduction Thank you for selecting the Extech Instruments Model RH25 Heat Index Psychrometer. The RH25 measures Temperature and Relative Humidity (using
More informationER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller
PB_ER65-DRW_ 202 ER65-DRW Controller Heating Applications Product Bulletin The controller is a digital device for domestic or residential heating units. It covers water and air heating applications. All-in-one
More informationST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number
ST71-KHJV.3 Temperature controller Order number 921.8 Wiring diagram Product description The switching outputs of the thermal controller can be programmed as -two-point controller with alarm -three-point
More informationGREEN LEAF PROGRAMMABLE THERMOSTAT FOR ELECTRICAL FLOOR HEATING INSTALLATION INSTRUCTIONS. EN-RaychemGreenLeaf-IM-EU0209 THERMAL BUILDING SOLUTIONS
GREEN LEAF PROGRAMMABLE THERMOSTAT FOR ELECTRICAL FLOOR HEATING INSTALLATION INSTRUCTIONS pentairthermal.com/manuals/ THERMAL BUILDING SOLUTIONS EN-RaychemGreenLeaf-IM-EU0209 Rev2 CONTENTS 1. DESCRIPTION...3
More informationecoal.pl V3.5 Adaptive controller Operating manual Kutno Software version:
ecoal.pl V3.5 Adaptive controller Software version: 1.1.20.0 Operating manual Kutno 2016-10-07 Table of Contents 1. Safety...3 2. Assembly... 5 2.1 Environmental conditions...5 2.2 Control panel setup...5
More informationST Wiring diagram. Product description. Standard temperature controller. Order number
ST64-31.10 Standard temperature controller Order number 900197.007 Old Id.Nr.: 386169 Wiring diagram Product description The controller ST64-31.10 was developed for simple thermostatic controls. The round
More informationControl Application. Supplement - ACVMax
prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions
More informationOperation Instruction
Operation Instruction SR81 Intelligent Controller for Split Pressurized Solar Hot Water System Please read this instruction carefully! Contents 1.Safety information... 3 1.1 Installation and commissioning...
More informationOPERATION MANUAL. Indoor unit for hot water heat pump system and options EKHBH016AB EKHBX016AB
OPERATION MANUAL Indoor unit for hot water heat pump system and options EKHBH016AB EKHBX016AB EKHBH016AB*** EKHBX016AB*** Indoor unit for hot water heat pump system and options CONTENTS Page Introduction...1
More informationWall Hung Boiler Room Thermostat OR30 OT Thermostat
8 733 201 137-00.1O Wall Hung Boiler Room Thermostat OR30 OT Thermostat Operating Instruction 6 720 812 418 (2014/07) en 2 Contents Contents 1 Symbols and safety precautions..................................
More informationDanfoss gas detection unit Type GD Heavy Duty
Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx
More informationV. DIFFERENTIAL THERMOSTAT
DTC 200/2G DTC 200/2G is a differential thermostat, designed for heating DHWT (domestic hot water tank) from one heating source (solar collectors, boilers, heat pumps) with possibility to control the burner
More informationMS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack
Product/Technical MS4PMUHVT Issue Date 09/30/02 MS4PMUHVT Multi-Stage Electronic Control with Relay Pack The MS4PMUHVT Multi-Stage Electronic Control is intended for multi-stage temperature control applications.
More informationNo part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic,
No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic, mechanical, by photocopying, recording or in any other manner
More informationMonitoring Software for NPBC-V3M-1 User Manual
Monitoring Software for NPBC-V3M-1 User Manual User Manual ver 1.5 page 1 of 14 Contents: 1. Introduction... 3 2. Requirements... 3 3. Installing the software... 4 4. Connecting the devices... 4 5. Updating
More informationVMB1TSW Temperature sensor module for the Velbus system
VMB1TSW Temperature sensor module for the Velbus system CONTENTS DESCRIPTION... 3 CHARACTERISTICS... 3 VELBUS CHARACTERISTICS... 5 OVERVIEW SENSOR MODULE... 7 EMBEDDING THE TEMPERATURE SENSOR... 8 EMBEDDING
More information1 DOCUMENT REVISION CONTROL ELEMENTS... 9
CONTENTS Contents 1 DOCUMENT REVISION... 8 2 SOFTWARE VERSION... 8 3 BASIC DESCRIPTION... 8 4 CONTROL ELEMENTS... 9 4.1 BASIC DISPLAYS...10 4.2 CONTROL KEYS...11 4.2.1 Rotary button (Press / Turn)...11
More informationLCF Touch (from firmware version 1.7)
LCF Touch (from firmware version 1.7) Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet Subject to technical alteration Issue date: 26.1.216 Application Modern design flush mounting
More informationETO 2 - Controller for ice and snow melting
ETO 2 - Controller for ice and snow melting Advantages Simple adjustment knob with two functions Illuminated display where you can easily see the temperature status and other values Controls both pumps
More informationJDDT1 - Single Stage Digital Thermostat
JDDT1 - Single Stage Digital Thermostat CAUTION NOTICE: The thermostat must be installed by authorized professionals. It should be located in a place free of vibrations, impacts, and corrosive gases. SET
More informationSemi flush-mount room thermostats
s 1 440 RDD310/EH RDE410/EH Semi flush-mount room thermostats for control of electric floor heating systems and for hydronic zone control systems RDD310/EH RDE410/EH Key features of both types of thermostats:
More informationProgrammable Room Thermostat Installation Instructions
ESRTP4 Programmable Room Thermostat Installation Instructions Thank you for choosing ESi Controls. All our products are tested in the UK so we are confident this product will reach you in perfect condition
More informationT60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability
T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability Product Bulletin T601DFH-4, T602DFH-4, T603DFH-4, T604DFH-4, T605DFH-4, T601DFH-4+PIR, T602DFH-4+PIR,
More informationT-32-TS Touchscreen Thermostat. Installation Manual
T-32-TS Touchscreen Thermostat Installation Manual TABLE OF CONTENTS Introduction...4 Getting Started...5 Installing the Thermostat...6, 8 Disassembly...6 Thermostat Location...6 Mounting the Subbase...6,
More informationDigital regulator for refrigeration and defrosting, 3 relays.
Installation guide ERC 213 Digital regulator for refrigeration and defrosting, 3 relays. 520H11062 The ERC 213 is a smart, multipurpose refrigeration controller with temperature and defrost management,
More informationINSTRUCTION FOR THE USER THC V E OIL BLU
INSTRUCTION FOR THE THC V E OIL BLU CONTENTS General safety information 4 Precautions 4 Control panel 5 Mode selection 8 User levels 10 Start-up 12 Temporary shutdown 15 Preparing for extended periods
More informationMulti Boiler Guide. Kit #
Multi Boiler Guide Kit # 550002186 Technical Support @ 800-325-5479 Phone: (315) 797-1310 Fax: (866) 432-7329 e-mail: info@ecrinternational.com web site: www.ecrinternational.com Information and specifications
More informationHIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER
This manual must be left with owner and should be hung on or adjacent to the boiler for reference. US HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER MODELS CHS-85 through CHS-399 APPENDIX A CONTROLLER
More informationMR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack
Master Catalog 125 Temperature Controls Section A Product/Technical Bulletin Issue Date 1098 MR4PMUHV Electronic Temperature/Defrost Control with Relay Pack The MR series temperature controls are designed
More informationER52 - Evaporator Controller
ER52 - Evaporator Controller Electronic Refrigeration Line Product Bulletin Devices are standalone digital controller for static or ventilated refrigeration units working at positive temperatures. They
More informationTPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating
TPOne-B Electronic Programmable Room Thermostat Danfoss Heating Installation Guide TPOne is an intelligent programmable heating control made easy. TPOne includes features which are designed to save energy.
More informationUSER'S INFORMATION MANUAL
USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use
More informationprestige Control Application Supplement WARNING
prestige Control Application Supplement WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions within this
More informationENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE
ENERGY LIGHT USER S GUIDE Release January 2001 CONTENTS 1.0 GENERAL CHARACTERISTICS... 4 1.1 MAIN CHARACTERIS TICS... 4 2.0 USER INTERFACE (CODE C5121230)... 5 2.1 DISPLAY... 5 2.2 MEANING OF THE LEDS...
More informationImmersion Temperature Controller
3 333 Synco 100 Immersion emperature Controller with 2 outputs DC 0 RLE162 Immersion temperature controller for water-side control in heating and cooling plants Compact design with 2 analog control outputs
More informationTEC2100 Series Networked Thermostats
Product Bulletin Issue Date February 11, 2004 TEC2100 Series Networked Thermostats The TEC2100 Series of thermostats is a family of highly advanced thermostats specifically designed for control of equipment
More informationUSER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort
USER MANUAL S203 Controller for three circuits - control for 2 heating circuits - 1 domestic hot water control Saving energy, creating comfort This user manual consists of two parts. Issues that are intended
More informationGH10PA USER MANUAL. Program version 01 MANUAL FOR CONTROLLER FOR CONTROLLING CENTRAL HEATING BOILERS FIRED WITH PELLETS AND OATS
MANUAL FOR CONTROLLER GH10PA FOR CONTROLLING CENTRAL HEATING BOILERS FIRED WITH PELLETS AND OATS Program version 01 USER MANUAL We request that users carefully study applicable Instructions before connecting
More information1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY
RC 06 0712_1403 it - Istruzioni TELECONTROLLO en - Remote controller instruction hu - Utasítás TÁVVEZÉRLÉS ru - Руководство по эксплуатации pl - Instrukcja obsługi { 1. Commissioning of the boiler 26 2.
More informationEC3-X33 Stand-alone Superheat Controller Technical Data
Technical Data EC3-X33 is a stand-alone universal superheat controller for air conditioning, refrigeration and industrial applications such as chillers, industrial process cooling, rooftops, heat pumps,
More informationDT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET
DT92 WIRELESS DIGITAL ROOM THERMOSTAT PRODUCT SPECIFICATION SHEET The new DT92 family of wireless digital room thermostats is a range of market leading products designed to provide comfort with economy
More informationOPERATION MANUAL RK-2001W2 SOLID FUEL FIRED BOILER TEMPERATURE CONTROLLER. Version 9A15
OPERATION MANUAL RK-2001W2 SOLID FUEL FIRED BOILER TEMPERATURE CONTROLLER Version 9A15 1. Application. RK-2001W2 controller is a controller designed for temperature control of solid fuel fired boilers.
More informationHeating and D.h.w. Controller RVL482 Basic Documentation
Heating and D.h.w. Controller RVL482 Basic Documentation Edition: 1.0 Controller series: A CE1P2542en 20.05.2008 Building Technologies Siemens Switzerland Ltd Building Technologies Group International
More informationThermometers and temperature controllers
D144H002 Ed.07 GB Thermometers and temperature controllers User Manual Contents AKO Electromecánica thanks and congratulates you for purchasing our product, in whose development and manufacture the most
More informationFollett Performance Plus
Follett Performance Plus touchscreen user guide The next level of control in undercounter refrigeration Controller Operation - Performance Plus touchscreen Use and care of the LCD Performance Plus touchscreen
More informationprestige Control Application Supplement - ACVMax
2015-10 Prestige ACVMax Control Sup 12-14-15_ACVMax_Control 12/15/15 7:36 AM Page 1 prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory
More informationbruli.pl V3.5 Operating manual Kutno Software version:
bruli.pl V3.5 Software version: 1.1.20.0 Operating manual Kutno 2016-10-07 Table of Contents 1. Safety...3 2. Assembly...5 2.1 Environmental conditions...5 2.2 Control panel setup...5 2.3 Connecting the
More informationTEC210x-2 Series Networked Thermostats
Product Bulletin Issue Date February 1, 2005 TEC210x-2 Series Networked Thermostats The TEC210x-2 Series of thermostats is a family of highly advanced thermostats specifically designed for control of equipment
More informationModulating clock thermostat
EN Digital timer thermosatat Modulating clock thermostat Installation and Service Manual 123189-AB Contents 1 Preface...4 1.1 General...4 2 Location of the installation...5 2.1 Position of the regulator...5
More informationZIP Economizer Method of Operation Sequence of Operation States Virgin State The ZIP Economizer comes shipped from the factory in this state. Setup Incomplete will be displayed. No control will occur until
More informationModel: RT310RF. Installation Manual
Model: RT310RF Installation Manual Contents Product Compliance... 3 Safety Information... 3 Box Content... 3 Introduction... 4 Features... 5 Installation... 5 Button functions and keys... 7 Installer mode...
More informationRS Pro Infrared Temperature Sensor
Instruction Manual RS Pro Infrared Temperature Sensor Stock Number: 161-8103 Introduction The RS Pro Infrared Temperature Sensor is a device for measuring the temperature of the surface of a solid or liquid
More informationSR501. Please read the manual carefully before operation!
SR501 Please read the manual carefully before operation! Contents 1. Safety information... 3 1.1 Installation and commissioning... 3 1.2 Liability waiver... 3 1.3 Signal description... 4 2. Installation...
More informationSD2. Differential Controller. Operating and Installation Instructions F2 72.3
SD2 Differential Controller Operating and Installation Instructions F2 72.3 i Please follow the safety information and read these Instructions carefully before putting the system into operation. Safety
More informationDanfoss gas detection units
Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning
More informationModel: RT310. Installation Manual
Model: RT310 Installation Manual Contents Product Compliance... 3 Safety Information... 3 Box Content... 3 Introduction... 4 Features... 5 Installation... 5 Button functions and keys... 7 Installer Mode...
More informationZL-7901A Intelligent temperature and humidity controller Instruction Manual A1.0
ZL-7901A Intelligent temperature and humidity controller Instruction Manual A1.0 Feature ZL-7901A is an industrial intelligent temperature and humidity controller. It can connect SSR expire output and
More informationUSER'S INFORMATION MANUAL
USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use
More informationDEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive
DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive www.devi.com Table of Contents 1. Introduction..................................... 2 2. Technical Specifications.........................
More informationINTELLIGENT ROOM THERMOSTAT
INTELLIGENT ROOM THERMOSTAT LARGE BACKLIT DISPLAY with intuitive navigation in CZ/PL/EN/DE/RU/SK 9 WEEKLY PROGRAMS and 6 temperature changes per day HYSTERESIS/ PI/PID REGULATION selection according to
More informationRoom thermostat with Auto Timer, Option External Input
s 1 422 Room thermostat with Auto imer, Option External Input for heating systems RDE100.. Room temperature control 2-position control with On/Off output for heating Comfort, Economy, Auto timer and Protection
More informationInstallation & User s Instructions
Installation & User s Instructions 8 080 shown Part No. 00 day Wired Digital Programmer & Room Sensor Part No. 080 day Wireless Digital Programmer & Room Sensor Part No. 00 hr Wireless Digital Programmer
More informationRVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating
2 526 Heating Controller including dhw heating Series C RVL472 Multifunctional heating controller for use in residential and non-residential buildings Suited for: Heating zone control with or without room
More informationWireless room thermostat with LCD
s 1 424 RDD100.1RF RCR100RF Wireless room thermostat with LCD for heating systems RDD100.1RFS Roomom temperature control Comfort, Economy and Protection mode 2-position control with On/Off control output
More informationPipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual
MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...
More informationEXPERT TRI-STAR. Temperature controller. User s Manual
Temperature controller r s Manual WARNINGS The warranty can be void if this product is used in a manner not specified by the manufacturer. Every effort has been made to ensure that this manual is complete,
More informationNo. Icon Name Function
Use The room unit is intended for basic users control and monitoring of the function of Mandík air conditioning units incl. basic parameters. The measurement of temperature of the room, where the room
More informationXWA11V. Walk-In Temp / Door /Alarm / Light Module
XWA11V Walk-In Temp / Door /Alarm / Light Module 1. GENERAL DESCRIPTION Model XWA11V, 100x64 mm format, is a microprocessor-based controller, suitable for temperature monitoring and alarming in a walk-in
More informationOPERATION INSTRUCTION
OPERATION INSTRUCTION Working station for split water heater: SP118 and SP228 Contents 1.Instruction 2.Attention 3.Liability waiver 4.Single pipeline working station system SP118 4.1.Main technical date
More informationInstallation Guide. DEVIreg 535. Electronic Thermostat.
Installation Guide DEVIreg 535 Electronic Thermostat www.devi.com The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive
More informationMODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL
TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External
More informationSingle Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual
We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More informationEBC20. Instructions for fitting, installation and operation. Read and save these instructions!
EBC20 UK Instructions for fitting, installation and operation Read and save these instructions! 2 3002878 EBC20 UK 290415 1. Product information............................................... 4 1.1 Delivery.............................................................
More informationOperation Manual of Solar Controller SR658 for Split Solar System
Operation Manual of Solar Controller SR658 for Split Solar System Read the instruction carefully please before operation! Contents 1. Safety information... 4 1.1 Installation and commissioning... 4 1.2
More informationRF Programmable Room Thermostat Installation Instructions
ESRTP4RF RF Programmable Room Thermostat Installation Instructions Thank you for choosing ESi Controls. All our products are tested in the UK so we are confident this product will reach you in perfect
More informationOutdoor Reset IQ Option Card, p/n
Outdoor Reset IQ Option Card, p/n 102723-01 Instruction Sheet CONTENTS Application... 1 General... 2 How it Works... 3 Installation.... 5 Wiring... 7 User Interface... 10 Using IQ Option Panel Display...
More informationPRELIMINARY EDITION
3 131 PRELIMINARY EDITION 14.01.2003 Synco 700 Heating Controllers Heating controller for medium-size and large buildings. The is used as a heating circuit or primary controller. The controller is supplied
More informationService Manual Models:
KBXII-SER Rev A Models: 400-801 WARNING This manual must only be used by a qualified heating installer / service technician. Read all instructions, including this manual and the Knight XL Installation
More informationprestige Control Application Supplement - TriMax
prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions
More informationEM300(LX) electronic digital indicator. Alarm (IF PRESENT) ON for active alarm; blinking for silenced alarm that is still present
EM3(LX) GB code 9IS4349 rel. 66 electronic digital indicator USER INTERFACE The user has a display and four buttons for controlling instrument status and programming. BUTTONS AND MENUS ACCESSING UP Button
More informationWIO200 Water In Oil measuring instrument
WIO200 Water In Oil measuring instrument You have made the right decision by choosing a measuring instrument from PAJ Systemteknik. Many customers buy our high standard products every year. There are at
More informationSUPPLY TO CENTRAL HEATING SYSTEM SUPPLY TO DHW TANK RETURN FROM CENTRAL HEATING SYSTEM RETURN FROM DHW TANK
This booklet will assist you in piping, wiring and setting the controls of the Riva Advance SV boiler to control an indirect fired hot water tank. All pipe tails for the connection to the tank are supplied
More informationPROGRAMMABLE 7-DAY THERMOSTAT
PROGRAMMABLE 7-DAY THERMOSTAT Installation and user instruction This instructions to be retained by the user 1 Thank you for choosing Riello s weekly programmer.. This central heating control device is
More informationDPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-
DPR-45 User Manual V-2.0 (2..206) DPR-45 TEMPERATURE PROTECTION RELAY PT00 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT 9-50VDC SUPPLY DESCRIPTION DPR-45 is a precision unit designed for the temperature
More information