Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

Size: px
Start display at page:

Download "Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S"

Transcription

1

2 D10 is a type-approved measuring device which combines the advantages of the measuring principles transmittance and scattered light forward. Therefore, it is ideal for measurement of very low to high dust concentrations. The automatic self-alignment optimized the position of the measuring beam and prevents incorrect measurement. An automatic check of zero and referencepoints as well as a contamination monitoring. Product Overview Dust & Opacity Analyzer Combination of transmittance and scattered light measurement. For very low to high dust concentrations. Automatic check of zero and reference point. Contamination monitoring and compensation on both sides. Automatic self-alignment. For medium to large dust diameters. Application Solid Fuel Boiler Gas Fuel Boiler Tunnel for Visibility Generator Emission Diesel Car Emission Rubbish Incinerator Power Plant Boiler Furnance Waste Incinerator Field Application Emission Monitoring of power stations and waste incinerator plants. Monitoring of filter facilities. Measurement of dust concentrations in exhaust gas and exhaust air ducts up and downstream of a filter Benefits Suitable for highly fluctuating dust concentrations. Reliable application due to redundant measurement. Low maintenance due to self-monitoring function. Future-proof for decreasing limit values. Ordering Information DM-LK-D10 DM-LK-D10-C SDS-V5 SDR-V4 HPB-82S Description Dust & Opacity Meter Complete Set Controller Unit Auto Cleaner

3 Controller Unit Continuous monitoring in % (Opacity) and mg/m 3 (Dust). Alarm contact for exceeded limit. Aid to Efficiency of combustion. Meet to the Department of Environmental Emission Standard Regulation. Acknowledge Buzzer function. 4-20mA Analog output for Dust and Opacity. RS485 Modbus Communication. Automatic Zero and Span check. Certification CE Mark by TUV. Screen Width Power Power Consumption Ambient Temperature Alarm Contact Measuring Range Engineering Unit Mounting Panel Cut-Out Size Dimension Sampling Time Display Accuracy Operating Temperature Operating Humidity Protection Certification Report No. Conformity Emission Compensation to mg/nm3 Fail Safe Shutter Double Pass Beam D10 LCD 70 x 38mm VAC; 50/60 Hz 20 Watt -10 ~ 50 C Max 5A / 240VAC - SPDT Relay 0-100% (Opacity), mg/m 3 (Dust) Percent Obscuration (%) - Opacity mg/m 3 - Dust Concentration Panel or Wall W137 ± 1 x H137 ± 1 x D90 (mm) W150 x H150 x D110 (mm) 1 Kg 0.2 seconds ±1.0% F.S 0 C to 55 C 20 to 80% RH Max. (Non-condensing) IP65 Front Panel CE Mark by TUV (AE ) / 108 / EC EN : 2013 Required Temperature & Pressure Measurement Optional Optional

4 Surface Wall Mounting Front View Back View Side View Flush Panel Mounting Front View Back View Side View Sensor Mounted on opposite sides of the stack or duct. light beam is at right angles to the flow or flue gases and give unrestricted illumination of the receiver solar cell. Preferable that unit installing where the temperature is at minimum. Enclosure Class Sensor Body Material Element Flange Mounting Size Air Pressurized Adapter Design Body SDS-LK-SV5 SDR-LK-RV4 IP65 Aluminium Alloy Light Emitting Diode 146mm P.C.D, Ø18mm Holes, C.T.C : 102mm 1/4" BSP Thread Weather proof IP65 Max. Ambient Temperature 70 C Max. Stack Temperature 1200 C Swing Door 90 minimum 2.0 Kg Certification CE Mark by TUV

5 Auto Cleaner Ambient Temperature Power Supply Material Connection Static Pressure Capacity Accessories HPB-82S 25 C and 50 C Single Phase : VAC, 50Hz 3 Phase : VAC, 60Hz Cast Aluminium DN40 BSP 120 mbar 140m 3 /Hr 40Kg Hose x 10 meter, Y-Joint x 1 & Hose Clip x 6 Typical Installation RMU D10 Controller Rock Wool Insulation Cloud System OR Optional: Auto Cleaner : HP-82S PC Data Logger LKS (M) SDN BHD No.15, Jalan Anggerik Mokara, 31/63, Kota Kemuning, Shah Alam, Selangor Tel : Fax : info@lkssb.com Website :

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR The EMS510 provides continuous, low maintenance, precision measurement of Opacity and Dust (mg/m3). It is designed for monitoring visible smoke in the exhaust

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the D-R 290 Opacity and Dust Concentration Monitor manufactured by: DURAG GmbH Kollaustraße 105 22453 Hamburg Germany has been assessed by Sira Certification

More information

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2 Features Integrated (built-in NO2 sensor / detector (Electro chemical sensor type Measuring ranges 0-10 ppm, 0-20 ppm or 0-30 ppm LCD display to show actual in ppm Status LED indication Normal operation

More information

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS 4500MkIII COMPLIANCE OPACITY AND DUST MONITORING i QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS 4500MkIII AMETEK LAND HAS BEEN MANUFACTURING PRECISION MEASURING EQUIPMENT SINCE 1947.

More information

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output Features Electrochemical sensor element (0)2-10 Vdc or (0)4-20 ma output, jumper selectable Standard IP65 plastic enclosure Measuring ranges 0-50 ppm 0-100 ppm 0-150 ppm 0-200 ppm 0-250 ppm 0-300 ppm 0-500

More information

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES USER INSTRUCTIONS FOR THE CHEMGARD INFRARED GAS MONITOR SERIES To completely customize the specification to your exact application, modification to the

More information

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc.

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc. CEMS Operating Manual IMR USA S/N: Sample IMR 5000 IMR 400 IMR 400 IMR 5000 Measure MESURE PURGE Purge CALIBRATE Calibrate OFF OFF RESET Measure ON ON Calibrate RESET PUMP Gas Dryer Inside PUMP Sensors

More information

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660 Selectivity Adjustable by Means of - High Pass Frequency Filter - Gain - Threshold Different Adjustments for Different Conditions (e.g. According Fuel or Combustion Technology) Possible, to be Activated

More information

S304 and S305 Dust Emission Monitors. User Manual. Distributor

S304 and S305 Dust Emission Monitors. User Manual. Distributor S304 and S305 Dust Emission Monitors User Manual Distributor Version 6.4 30/5/2012 Table of Contents 1. INTRODUCTION... 3 1.1 Safety... 3 1.2 Product overview... 4 1.3 Principle of operation... 4 2. INSTALLATION...

More information

Dust Alert 75. *shown with optional external keypad and display

Dust Alert 75. *shown with optional external keypad and display Dust Alert 75 Designed to differentiate between gross failure and dust leakage from faulty/failing filter systems including bag filters Automatic internal zero and reference self-checks for regulatory

More information

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger

More information

Analog Room Pressure Monitor RPC Series

Analog Room Pressure Monitor RPC Series Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the

More information

Multi-Gas-Controller MGC2

Multi-Gas-Controller MGC2 Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants

More information

Gas cooler series TC-Standard+

Gas cooler series TC-Standard+ Gas Analysis Gas cooler series In emission measurement, process control relies on prompt and exact determination of the operating parameters. Here, gas analysis is the key for safe and efficient control

More information

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers PRODUCT INFORMATION GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL In-situ Gas Analyzers MONITORING CARBON MONOXIDE EMISSIONS INNOVATIVELY AND EFFICIENTLY

More information

Certificate: _01 / 22 March 2013

Certificate: _01 / 22 March 2013 Test report: 936/21219384/B of 27 September 2012 Initial certification: 20 July 2012 Expiry date: 19 July 2017 Publication: BAnz AT 05 March 2013 B10, chapter I, No. 1.5 Approved application The tested

More information

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications Data Sheet Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications Ideal for small gas/oil fired boilers Cost effective solution for OEM outlets with a quick return on end-user investment Continuous

More information

Meets all design requirements of U.S.EPA. Double pass optical system for accuracy and sensitivity. Modulated light beam to eliminate interference

Meets all design requirements of U.S.EPA. Double pass optical system for accuracy and sensitivity. Modulated light beam to eliminate interference The Visible Emission Monitor Opacity Meter and/or Dust Concentration Meter U.S.EPA Compliance D-R 281 AV Opacity/Dust Concentration Monitor with dual channel capability The DURAG D-R 281 AV Visible Emission

More information

Certificate: _01 / 22 March 2013

Certificate: _01 / 22 March 2013 Test report: 936/21219384/A of 27 September 2012 Initial certification: 20 July 2012 Expiry date: 19 July 2017 Publication: BAnz AT 05 March 2013 B10, chapter I, No. 1.6 Approved application The tested

More information

1 of 25 LKS (M) SDN BHD. Floatless Water Level Control WLAPC-FL- PN16XX. SPD for Power Class B LP-75B. Industrial & Marine application Model: FLR EH

1 of 25 LKS (M) SDN BHD. Floatless Water Level Control WLAPC-FL- PN16XX. SPD for Power Class B LP-75B. Industrial & Marine application Model: FLR EH LKS (M) SDN BHD Floatless Water Level Control WLAPC-FL- PN16XX Industrial & Marine application Model: FLR EH Measuring principle Conductive measurement resistance from reference point to Switching electrode

More information

Beck. The differential pressure transmitter for air

Beck. The differential pressure transmitter for air Beck. The differential pressure transmitter for air Differential pressure transmitter 984 General description The differential pressure transmitters of the 984 series are used to measure differential pressure,

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T P R O D U C T D ATA S H E E T www.internationalgasdetectors.com Transmitters Control Systems OLIVER Sensors IGD Accessories TOCSIN 640 Pre-Configured Gas Detection System, CO2, O2 or N2O With all the features

More information

Warranty Registration

Warranty Registration WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship and materials for a period

More information

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 8000 Stationary gas detector (EC) Dräger Polytron 8000 Stationary gas detector (EC) The microprocessor-based transmitter can be equipped with various electrochemical DrägerSensors. This way, you can easily detect oxygen and various toxic

More information

OPAL 200S SERIES OPERATOR AND SERVICE MANUAL OPAL 200 OPACITY & DUST MONITORING SYSTEM OPERATION AND SERVICE MANUAL. Feb-09 1 Revision 1 V46

OPAL 200S SERIES OPERATOR AND SERVICE MANUAL OPAL 200 OPACITY & DUST MONITORING SYSTEM OPERATION AND SERVICE MANUAL. Feb-09 1 Revision 1 V46 OPAL 200 OPACITY & DUST MONITORING SYSTEM OPERATION AND SERVICE MANUAL Feb-09 1 Revision 1 V46 Product Registration 3 Service Support Procedures 4 SECTION 1 OPAL 200 OPTICAL SYSTEM. 5 1.1 General Description

More information

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters

More information

continuous emissions monitoring Combustion & Environmental Monitoring

continuous emissions monitoring Combustion & Environmental Monitoring continuous emissions monitoring Combustion & Environmental Monitoring Advanced CEM technology for accurate measurement and high reliability - to meet today s regulatory requirements and ready for future

More information

UV Flame Supervision System

UV Flame Supervision System 7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running

More information

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes 1129 PHOTO PHOTO PARTICUR Sensor SERIES Related Information General terms and conditions... F-3 About laser beam... P.193~ guide... P.121~ General precautions... P.19 Conforming to FDA regulations (-11

More information

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc. IMR 5000 Operating Manual S/N: For information only! IMR Environmental Equipment Inc. INTRODUCTION 3 SAFETY INSTRUCTIONS 3 SYSTEM DESCRIPTION - IMR 5000 GAS ANALYSIS SYSTEM 4 Function chart IMR 5000 -

More information

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

PolyGard Digital Gas Controller DGC-05 RS-485 Bus PolyGard Digital Gas Controller DGC05 RS485 DESCRIPTION Gas measuring controller series for continuous monitoring and warning of toxic, combustible and refrigerant gases and vapours. The gas controller

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the StackFlowMaster System Manufactured by: ABB Ltd Oldends Lane Stonehouse Gloucestershire GL10 3TA Has been assessed by Sira Certification Service

More information

Certificate: / 29 April 2014

Certificate: / 29 April 2014 Test report: 936/21217455/A of 10 September 2013 Initial certification: 01 April 2014 Expiry date: 31 March 2019 Publication: BAnz AT 01 April 2014 B12, chapter I, No. 1.1 Approved application The tested

More information

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger PointGard 2100 Detection of toxic gases and vapours Dräger PointGard 2100 Detection of toxic gases and vapours The Dräger PointGard 2100 series is a self-contained gas detection system for the continuous area monitoring of toxic gases in ambient air PointGard

More information

UDC100 Universal Digital Controller Specifications

UDC100 Universal Digital Controller Specifications UDC100 Universal Digital Controller Specifications 51-52-03-29 November 1999 Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines

More information

Zircomat Oxygen Analyzers

Zircomat Oxygen Analyzers Zircomat Oxygen Analyzers Finally Hassle Free Stack Gas Oxygen Measurement Many of the top fortune 500 companies have already discovered that installing a ZIRCOMAT Oxygen analyzer is the smart way to measure

More information

Snifter. User Manual. Distributor

Snifter. User Manual. Distributor Snifter User Manual Distributor Version 1.3 08/09/2009 1 Table of Contents 1. INTRODUCTION... 3 1.1 Safety... 3 1.2 Product overview... 3 1.3 How does it work?... 3 2. INSTALLATION... 4 2.1 Selecting the

More information

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options. All icon products are Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options. Certified to global standards: ATEX, IECEx, TIIS, EAC-EX, ETL approved

More information

The A-series Eletta Flow Monitor with local indication and analog output

The A-series Eletta Flow Monitor with local indication and analog output The A-series Eletta Flow Monitor with local indication and analog output GL series FA series GSS series FSS series The Pipe Section is constructed of copper alloy and fitted with BSP/NPT threads from 15

More information

RS /E-EV C01 SERIES

RS /E-EV C01 SERIES The well-known RS 300-800/E-EV Burner Series, till now available up to 8 MW, has been upgraded with two new powerful burner models, the RS 1000-1200/E-EV models that extend his max output up to 12 MW and

More information

COMPACT FLAME CONTROLLER CFC 100

COMPACT FLAME CONTROLLER CFC 100 COMPACT FLAME CONTROLLER CFC 100 TECHNICAL DESCRIPTION EDITION: TB CFC100 EN REV. 1 2012-03-07 IMPORTANT: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring

More information

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary

More information

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY >OLYL >H]LSLUN[O 4H[[LYZ SMOKELESS FLARE MONITOR Smokeless Flare Monitor (FM) Smokeless flares incinerate flammable hazardous

More information

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min Heat on Air heaters from 400 Watt to 17 400 Watt Blowers from 1,45 m 3 /min to 16,5 m 3 /min BAK Thermoplastic Need-to-know Calculation of air heaters 1. Heat requirement calculation Formula: Q = m * c

More information

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES PROCESS ANALYZERS DF-340E The DF-340E is a Coulometric sensor based oxygen analyzer suitable for outdoor installation and designed to measure trace oxygen and percent level in pure and multigas backgrounds.

More information

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer Model 6650SP Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer 6650SP - OVERVIEW The Model 6650SP is the next generation in-water Analyzer. The 6650SP incorporates the most advanced, state-of-the-art

More information

A New Standard of Excellence

A New Standard of Excellence A New Standard of Excellence PREVENTION IS SO EASY... LIVING THROUGH A DISASTER IS NOT The reliable identification of low combustion oxygen in a fired heater or boiler has always been critical to the effectiveness

More information

Carbon Monoxide CO Transmitter ADT-X3-1110

Carbon Monoxide CO Transmitter ADT-X3-1110 Page 1 Sep. 2017 CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air to detect carbon monoxide concentrations (CO).

More information

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features: Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low cost package. Patented

More information

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 )

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 ) CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 ) Measure carbon dioxide (CO2), carbon monoxide (CO) and temperature (T) Infrared measurement technology (NDIR) Automatic calibration eliminates

More information

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements Specifications COMMANDER 150 Universal Process Indicator High visibility 6-digit LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T P R O D U C T D ATA S H E E T www.internationalgasdetectors.com Transmitters Control Systems Sensors Accessories TOCSIN 90 SYSTEM UPGRADE Use existing MK3 Pellistor Flammable Gas Sensors and upgrade to

More information

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11 Table of Contents INTRODUCTION 1 THEORY OR OPERATION 2 DESCRIPTION 5 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 SPECIFICATIONS 10 OPTIONS

More information

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Carbon Monoxide (CO) Gas Detector March 15 GCO 300 GCO Carbon Monoxide (CO) Gas Detector March 15 Features Output 4-20 ma or 2-10 Vdc Power supply 24 Vdc Ranges 0-100 ppm or 0-300 ppm IP65 enclosure with quick locking screws Digital measurement value processing

More information

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes 113 Sensor SERIES Related Information General terms and conditions... F-7 About laser beam... P.199~ Sensor selection guide... P.1~ General precautions... P.11 PHOTO PHOTO PARTICUR MEASURE ITY panasonic.net/id/pidsx/global

More information

Gas cooler series TC-Standard+ X2

Gas cooler series TC-Standard+ X2 Gas Analysis Gas cooler series In emission measurement, process control relies on prompt and exact determination of the operating parameters. Here, gas analysis is the key for safe and efficient control

More information

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

MSM400 Ultrasonic Suspended Solids Monitoring and Control System Product Data Sheet MSM400 Ultrasonic Suspended Solids Monitoring and Control System Continuous sludge discharge monitor for up to 50% suspended solid The MSM400 system contains a control unit and either

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland Precisely F}ight. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000053803 Certified AMS: Manufacturer: Test lnstitute: D-R 808 for dust DURAG GmbH Kollaustr.105 Hamburg German

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Gas Controller Module GC-06

Gas Controller Module GC-06 Page 1 Oct. 2015/2 Measuring, warning and controlling module for toxic, combustible and refrigerant gases and vapours. The gas controller series GC-06 is designed in accordance with the standard EN 50545-1.

More information

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207 EN - english Instructions for installation and operation Mobile humidity meter DP 207 Dear customers, Thank you very much for deciding in favour of the mobile humidity measuring instrument DP 207. Please

More information

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector Page 1 / 5 Gas detector Brief SEN series smart gas transmitter changes the gas concentration into standard 4~20mA current source signal, Online free parking digital free configuration,multi-parameter backlight

More information

Your competent partner for measuring and services.

Your competent partner for measuring and services. Your competent partner for measuring and services. Intuitive, efficient, reliable everything for facility management: Welcome to the Smart World of Testo. 1 Too cold, too draughty, too humid? With the

More information

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor

More information

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control. Détecteur de gaz OLCT80 Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Disponible en version déportée, ADF ou de SI

More information

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes 13 Sensor SERIES Related Information General terms and conditions... F-17 About laser beam... P.13~ Sensor selection guide... P.967~ General precautions... P.1 PHOTO PHOTO Conforming to EMC Directive Conforming

More information

Gas cooler series RC 1.1

Gas cooler series RC 1.1 Gas Analysis Gas cooler series In the chemical industry, petrochemistry or biochemistry, reliable process control relies on prompt and exact determination of the operating parameters. Here, gas analysis

More information

TR 0603mc U Solar Controller

TR 0603mc U Solar Controller TR 0603mc U Solar Controller Part #8718572810 Engineering Submittal Sheet 178 mm [7.00 inch] 8 90 mm [3.54 inch] 170 mm [6.69 inch] 170 mm [6.69 inch] 134 mm [5.28 inch] 106 mm [4.17 inch] 32 1.26 0.31

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance

More information

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger Polytron 8310 Stationary gas detector (DSIR) Stationary gas detector (DSIR) SIMPLE INSTRUMENT MANAGEMENT POISON-RESISTANT AND FAIL-SAFE THANKS TO DIGITAL COMMUNICATION The DrägerSensor IR offers several benefits: technological advantages such as

More information

portable gas analyser

portable gas analyser www..com portable gas analyser The largest of s analysers equipped with electrochemical cells. It can fit even up to 7 EC cells and up to 3 sensors. GA-60 has a large (320*240), graphical LCD with backlighting.

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

RS /E-EV C01 SERIES

RS /E-EV C01 SERIES The well-known RS 300-800/E-EV BLU Burner Series, till now available up to 8 MW, has been upgraded with two new powerful burner models, the RS 1000-1200/E-EV C01 models that extend his max output up to

More information

Model D12-IR. Digital Gas Transmitter...

Model D12-IR. Digital Gas Transmitter... Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact

More information

LOW NOx MODULATING GAS BURNERS

LOW NOx MODULATING GAS BURNERS RS/E - RS/EV BLU SERIES LOW NOx MODULATING GAS BURNERS RS/E - RS/EV BLU SERIES RS 300/E BLU 500/1350 3800 kw RS 400/E BLU 800/1800 4500 kw RS 300/EV BLU 500/1350 3800 kw RS 400/EV BLU 800/1800 4500 kw

More information

Sitron s CF Line of Flow Switch Monitors

Sitron s CF Line of Flow Switch Monitors Sitron s CF Line of Flow Switch Monitors Models: CF 12AC CF 12DC CF 420 F 420 RCF 420 Introduction Sitron s versatile and intelligent line of Thermal Dispersion Flow Switch Monitors are compact switches,

More information

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases DESCRIPTION Gas measuring and monitoring controller based on stateof-the-art microtechnology with integrated sensor for continuous monitoring

More information

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS Product Information GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS Gas Analyzers SOLUTION FOR CONTINUOUS HYDROCARBON MEASUREMENTS The compact GMS800 FIDOR extractive

More information

An ISO 9001 : 2008 Certified Company

An ISO 9001 : 2008 Certified Company NITROGEN TYRE AIR INFLATOR Model - FS 3500 TECHNICAL DETAILS Nitrogen purity Compressed air input range Nitrogen output N2 output pressure Nitrogen storage tank Motor power Motor voltage Weight Packing

More information

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture meas. according to ISO 8573 Residual oil content - particles - moisture DS 500 - the intelligent chart recorder of the next generation. The centerpiece of compressed air quality measurement is the chart

More information

Certificate: / 9 February 2011

Certificate: / 9 February 2011 Test report: 936/21212470/A of 1 October 2010 First certification: 26 January 2011 Run of validity until: 25 January 2016 Publication BAnz. 26 January 2011, No. 14, p. 294, Chapter I No. 1.1 Approved application

More information

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring Data Sheet 907021 Page 1/8 Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring For measuring relative air humidity, temperature, and carbon dioxide concentration

More information

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications: Industrial Chilled Mirror Hygrometer Integral frost/dew point measuring head Internal sample pump Optimal Response Injection System ForceFrost TM function Ice-Test user calibration verification User configurable

More information

Sintrol Snifter A1+ Manual. Version 1.2.2

Sintrol Snifter A1+ Manual. Version 1.2.2 Sintrol Snifter A1+ Manual Version 1.2.2 Table of Contents 1 INTRODUCTION... 3 1.1 Safety... 3 1.2 Product overview... 3 1.3 How does it work?... 3 2 INSTALLATION... 4 2.1 Selecting the installation location...

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland'S' Pretisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000037054_01 AMs designation: Manufacturer: Test Laboratory: EM-D 5100fordust HORIBA GmbH Kaplanstraße 5 3430

More information

Nitrogen Dioxide Stand-Alone Detector - Analog, ModBus

Nitrogen Dioxide Stand-Alone Detector - Analog, ModBus Features Internal function monitoring with integrated hardware watchdog Hardware and software according to SIL2 compliant development process Easy maintenance / calibration by replacing the sensor cartridge

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 8720 IR Detection of carbon dioxide Dräger Polytron 8720 IR Detection of carbon dioxide The Dräger Polytron 8720 IR is an advanced explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high performance

More information

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen PolyGard Single Point Controller SPC-X3-XX for Toxic Gases and Oxygen DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor and

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

/8 DIN Level Indicator

/8 DIN Level Indicator Data Sheet SS/_6 High visibility 5-digit LED display clear and accurate indication Analog and relay outputs as standard high, low, latch and rate alarms, plus isolated retransmission Maths functions included

More information

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02 7 783 ISO 9001 DETACTOGYR Flame Safeguard Series 02 The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors

More information

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM User Instructions For The Model 5200 Gas Monitor System To completely customize the specifications to your exact application, modifications to the following

More information

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19July2017. Köln, 17 August2012

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19July2017. Köln, 17 August2012 Umwelt Bundes Amt For our Environment A TÜVRheinland Precisely Right. CERTIFICATE on Product Conformity (QAL 1} Number of Certificate: 0000036942 Certified AMS: Manufacturer: Test Institute: Dusthunter

More information

Recalibrate the way you look at gas detection

Recalibrate the way you look at gas detection Catalogue Gas detection solution Recalibrate the way you look at gas detection Next generation gas detection for industrial refrigeration The next generation of Danfoss gas detectors are based on a digital

More information

Krypton K CL2. Measuring and control system for free chlorine. applications. description. Low maintenance by automatic sensor cleaning

Krypton K CL2. Measuring and control system for free chlorine. applications. description. Low maintenance by automatic sensor cleaning Low maintenance by automatic sensor cleaning Pressure-proof up to 6 bar at 20 C Higher safety by integrated flow monitoring applications Drinking Water / Beverages Food Industry Disinfection Cooling And

More information