Switches compliant with ATEX directive

Size: px
Start display at page:

Download "Switches compliant with ATEX directive"

Transcription

1 Switches compliant with ATEX directive General Catalogue -

2 Technical concepts page Position switches FD / FL series page 9 / Category Zone EPL Approvals 2G Gb Mb II 2G Ex ia IIC T6 Gb I Ex ia I Mb Product code extension -EX ATEX/EPL category /Mb 2G/Gb 2D/Db 3G/Gc 3D/Dc - - Position switches FM series page Category Zone EPL Approvals 2G Gb Mb II 2G Ex ia IIC T6 Gb I Ex ia I Mb Product code extension -EX ATEX/EPL category /Mb 2G/Gb 2D/Db 3G/Gc 3D/Dc - - Position switches FD / FL series page / 3 Category Zone EPL Approvals Product code extension 2D 2 Db II 2D Ex tb IIIC T80 C Db -EX8 ATEX/EPL category /Mb 2G/Gb 2D/Db G/Gc 3D/Dc Prewired position switches FA series page 9 Category Zone EPL Approvals 3D 3G 2 Dc Gc II 3D Ex tc IIIC T80 C Dc II 3G Ex nc IIC T6 Gc Product code extension -EX ATEX/EPL category /Mb 2G/Gb 2D/Db G/Gc 3D/Dc Position switches FD / FL series page 93 / 99 Category Zone EPL Approvals Product code extension 3D Dc II 3D Ex tc IIIC T80 C Dc -EX4 ATEX/EPL category /Mb 2G/Gb 2D/Db G/Gc 3D/Dc Accessories page General Catalogue - 6

3 Switches compliant with ATEX directive / Technical concepts ATEX Directive The ATEX mark ( Atmospheres Explosives) refers to two European directives concerning the risk of deflagration in potentially explosive atmospheres: - ATEX 94/9/EC: concerns the requirements for electrical and non-electrical equipment used in potentially explosive environments. According to this directive the manufacturer has to comply with the provided requirements and mark the articles in conformity with particular categories - ATEX 99/92/EC: regards the minimum safety and sanitary requirements that the user has to satisfy during the activity in potentially explosive environments. These directives determine the requirements for the safety and health protection of people, animals and property and carry several procedures for the conformity demonstration of equipment to the directive requirements. Classification of potentially explosive atmospheres. A potentially explosive atmosphere is an atmosphere that could become explosive according to the local conditions of work. Usually it consists in environments where it is present a mixture of air and flammable substances in the form of gas, smog, steams and dusts. The ATEX 99/92/EC directive defines for two types of explosive atmosphere, depending on the presence in the zone of gases or combustible dusts. Each area exposed to these types of explosive atmospheres is classified in three zones, according to the frequency and duration of the explosive atmosphere. For atmospheres with explosive gas, areas are classified in zones 0, and 2; for atmosphere with explosive dusts in zones, 2 and : - Zone 0/ : a place where gas or combustible dust is present permanently. Constant danger. Equipment of minimum category is required. - Zone /2 : a place where gas or combustible dust is likely to occur during normal operation. Potential danger. Equipment of minimum category 2 is required. - Zone 2/ : a place where gas or combustible dust is unlikely to occur or only for a short period. Lower danger. Equipment of minimum category 3 is required. It s under the responsibility of the final user to choose and classify the different zones and to use suitable equipments. Device categories acc. to ATEX directive and IEC standards ATEX 94/9/CE directive distinguishes equipment between two main groups: - Group I: equipment and systems for mining - Group II: equipment and systems for all other applications Equipment of the group I is divided in two further categories according to the required protection degree: - Category M: Equipment designed to assure a very high protection level - Category : Equipment designed to assure a high protection level Equipment of the group II is divided in three further categories according to the required protection degree: - Category : Equipment designed to assure a very high protection level (use in zones 0 and, and 2, 2 and ) - Category 2: Equipment designed to assure a high protection level (use in zones and 2, 2 and ) - Category 3: Equipment designed to assure a normal protection level (use in zones 2 and ) The relation between the EPL (Equipment Protection Levels) of the IEC 09-0 standard, and the categories and applications of the ATEX directive are shown in the table below. Table Classification of the environment and device according to ATEX directive and IEC 09 0 standard Environment characteristics Equipment characteristics Environment of application Flammable material Potentially explosive atmosphere Classification of potentially explosive atmospheres: ZONE acc. to ATEX 94/9/EC Required marking of the device: CATEGORY Required marking of the device: GROUP acc. to IEC 09-0 EPL Required protection level Mining M Ma I Mb high very high It is present continuously, for long periods or frequently 0 G Ga very high Gas It is likely to occur 2G Gb high Above ground It is unlikely to occur or, if it does, is likely to do infrequently and for a short period only 2 3G Gc normal II It is present continuously, for long periods or frequently D Da very high Dusts It is likely to occur 2 2D Db high It is unlikely to occur or, if it does, is likely to do infrequently and for a short period only 3D Dc normal General Catalogue -

4 Protection modes In order to avoid an explosion caused by the electrical ignition of an explosive atmosphere, it is possible to take different type of precautions: - Isolate the dangerous parts into housing in order to limit the explosion inside itself. - Avoid contact between ignition sources and the potentially explosive atmosphere interposing solid, liquid or gaseous materials. - Take measures in order to limit the generation of dangerous ignition sources, eliminating the possibility of faults or limiting the energy so it s not sufficient to cause the ignition. For each modality several methods of protection have been developed and standardized, as listed in the following table. Table 2 - Protection methods and reference standards Protection method Symbol Engraving General requirements Zone of utilization GAS Zone of utilization DUSTS / / 0,, 2, 2, Oil immersion Ex o.2 / Pressurization Ex px Ex py Ex pz Powder filling Ex q.2 / Flameproof Ex d.2 / Increased safety Ex e.2 / Intrinsic safety Encapsulation Non sparking Protective housing Ex ia Ex ib Ex ic Ex ma Ex mb Ex mc Ex na Ex nc Ex nr Ex ta Ex tb Ex tc Optical radiation Ex op 0,,2 / / / 2 IEC / EN standards IEC 09-0 EN 09-0 IEC 09-6 EN 09-6 IEC 09-2 EN 09-2 IEC 09- EN 09- IEC 09- EN 09- IEC 09- EN 09- IEC 09- EN 09- IEC 09- EN 09- IEC 09- EN 09- IEC 09-3 EN 09-3 IEC 09- EN 09- Marking examples Devices for places with presence of gas II 2G Ex ia IIC T6 Gb Community marking Equipment group (see table ) Protection category (see table ) Prefix for safety devices according to the IEC / EN standards Protection mode (see table 2) Classification of gases (see table 4) Temperature class (see table 3) EPL according to IEC 09-0 standard (see table ) Devices for places with presence of dusts II 3D Ex tc IIIC T80 C Dc Community marking Equipment group (see table ) Protection category (see table ) Prefix for safety devices according to the IEC / EN standards Protection mode (see table 2) Classification of dusts (see table ) Maximum surface temperature of the equipment EPL according to IEC 09-0 standard (see table ) Temperature classes Class T T2 T3 T4 T T6 Maximum surface temperature of the device Classification of gases T T2 T3 Table 3 40 C 0 C 0 C 3 C 00 C 8 C I IIA IIB IIC methane propane, methane, ethane, benzene, ammoniac, acetic acid, carbon monoxide, methanol, toluene ethanol, amyl acetate, butane naphtha, benzene, hexane acrylonitrile ethylene hydrogen sulfide T4 acetaldehyde ethyl ether T T6 Table 4 excerpt standard IEC 0 hydrogen acetylene carbon bisulphide Classification of dust Table IIIA IIIB IIIC combustible particles non-conductive powder conductive powder General Catalogue - 8

5 Switches compliant with ATEX directive / FD series Technical data Housing Metal housing, baked powder coating One threaded conduit entry: Protection degree: Mx. IP66 according to EN 29 with cable gland having equal or higher protection degree Main features Approvals: Category 2G and Metal housing, one conduit entry Protection degree IP66 Versions with gold-plated silver contacts ATEX markings and quality labels: II 2G Ex ia IIC T6 Gb I Ex ia I Mb General data Ambient temperature: - C + C Max. actuation frequency: 30 operating cycles /hour Mechanical endurance: F -EX 0 million operating cycles F 93-EX, F 8-EX, F 8 -EX, F 9-EX operating cycles F 99-EX, F R2-EX operating cycles Mounting position: any Safety parameters B 0d (NC contacts): F -EX,000,000 F 93-EX,F 8-EX, F 8 -EX,000,000 F 99-EX, F R2-EX 00,000 F 9-EX 2,00,00 Mechanical interlock, not coded: type according to EN ISO 49 Tightening torques for installation: see pages () One operation cycle means two movements, one to close and one to open contacts, as defined in EN 94. Cable cross section (flexible copper strands),: min. x 0.34 mm 2 ( x AWG ) max. 2 x. mm 2 (2 x AWG ) Contact block : min. x 0. mm 2 ( x AWG ) max. 2 x 2. mm 2 (2 x AWG 4) In conformity with standards: IEC 94--, EN 94--, EN 94-, EN 004, IEC 4-, EN 4-, EN ISO 49, EN ISO 200, IEC 29, EN 29, UL 08, CSA.2 No.4, IEC 09-0, EN 09-0, IEC 09-, EN 09-. In conformity with the requirements of: ATEX Directive 94/9/EC Low Voltage Directive 06/9/EC, Machinery Directive 06/42/EC and EMC Directive 04/08/EC. Positive contact opening in conformity with standards: IEC 94, EN 94. Installation for safety applications: Use only switches marked with the symbol aside the product code. Always connect the safety circuit to the NC contacts (normally closed contacts: -2, 2- or 3-32) as stated in standard EN 94, encl. K, par. 2. Actuate the switch at least up to the positive opening travel shown in the travel diagrams on page 238. Operate the switch at least with the positive opening force, indicated between brackets below each article, aside the minimum force value. If not expressly indicated in this chapter, for correct installation and utilization of all articles see chapter utilization requirements from page 23 to page 246. Category Zone EPL Approvals 2G Gb Mb II 2G Ex ia IIC T6 Gb I Ex ia I Mb Product code extension -EX Electrical data Maximum current ( i): 2. A Maximum voltage (Ui): Vdc Conditional short circuit current: 000 A according to EN 94 Protection against short circuits: fuse 4 A 20 V type gg Pollution degree: 3 This type of switches must be used only in intrinsic safety circuits in conformity with standard IEC 09, EN 09 For the correct utilization of the switch please use cable glands suitable for the zone according to the ATEX directive 9 General Catalogue -

6 6 Quality marks of the product: UL approval: EAC approval: Characteristics approved by UL Utilization categories Q0 (69 VA, 2 20 Vdc) A0 ( VA, 0 Vac) Data of housing type, 4X indoor use only, 2, 3 For all contact blocks except 2 and 3 use or C copper (Cu) conductor, rigid or flexible, wire size AWG 2/4. Terminal tightening torque of. lb in (0.8 Nm). For contact blocks 2 and 3 use or C copper (Cu) conductor, rigid or flexible, wire size AWG 4. Terminal tightening torque of 2 lb in (.4 Nm). E3 RU C-IT ДМ94.В.0024 In conformity with standard: UL 08, CSA.2 No.4 Please contact our technical service for the list of approved products. Adjustable levers Overturning levers Orientable heads In the switches it is possible to adjust the lever with 0 steps for the whole 3 range. The positive movement transmission is always guaran0 teed thanks to the particular geometrical coupling between the lever and the revolving shaft as prescribed for safety applications by the German standard BG-GS-ET-. In the switches, the lever can be fastened straight or reversed, maintaining the positive coupling. This makes it possible to have two different work plans of the lever. In all switches, it is possible to rotate the head in 90 steps. Unidirectional heads For switches with swivelling lever, it is possible to select the unidirectional operation by removing the four screws of the head and revolving the internal plunger. Code structure Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office. article options article FD 02-G-EX Housing FD ATEX approval metal, one conduit entry -EX II 2G Ex ia IIC T6 Gb I Ex ia I Mb 2 2, snap action 2NC, snap action 2NO, snap action, slow action 3NC, slow action 2NO+NC, slow action Actuators General Catalogue - short plunger roller lever... Threaded conduit entry Mx. Contact type silver contacts (standard) G silver contacts with µm gold coating 0

7 Switches compliant with ATEX directive / FD series With stainless steel roller on request With stainless steel roller on request R = snap action Ø0.6 Ø R L Max. speed x.3 FD 0--EX FD 0--EX.4 3 x.3 FD 02--EX FD 02--EX.4 3 x.3 FD 0--EX FD 0--EX.4 3 x.3 FD --EX FD --EX 0. m/s 0. m/s with cam at 0. m/s with cam at 0. m/s 8 N (2 N ) 6 N (2 N ) 6 N (2 N ) 8 N (2 N ) page group page group 2 page group 2 page group.4 3 With external rubber gasket Ball, Ø 2. mm, stainless steel With external rubber gasket Ø R L Max. speed x.3 FD --EX FD --EX.4 3 x.3 FD --EX FD --EX.4 3 x.3 FD 9--EX FD 9--EX.4 3 FD --EX FD --EX 0. m/s with cam at 0. m/s with cam at 0. m/s m/s N (2 N ) 8 N (2 N ) 8 N (2 N ) 0.09 Nm page group page group page group page group 3 x With external rubber gasket With external rubber gasket Bistable Rope switch for signalling 8 Ø.2 3. Ø R L Max. speed FD 2--EX FD 2--EX x FD 2--EX FD 2--EX x x x FD 4--EX FD --EX FD 6--EX 2NO+NC m/s m/s 0. m/s with cam at 0. m/s 0.08 Nm 0.4 Nm 0.2 Nm (0.36 Nm ) initial N - final N page group 3 page group 3 page group 4 page group 6 -EX II 2G Ex ia IIC T6 Gb I Ex ia I Mb 2G Gb Mb Accessories See page General Catalogue -

8 Position switches with revolving lever without actuator R = snap action Regular head M Compact head M IMPORTANT For safety applications: join only switches and actuators marked with symbol aside the product code. For more information about safety applications see details on page 23. R L x.3 FD 38--EX FD 38--EX Ø 3x x3x Ø Ø6x VF L3 VF L32 (2) VF L33 (2) () (2) Article VF L34 VF L3 VF L36 (2) Max. speed. m/s (cam at ). m/s. m/s m/s. m/s (cam at ). m/s Article (2) VF L VF L2 VF L3 VF L VF L Max. speed. m/s (cam at ). m/s (cam at ) 0. m/s. m/s (cam at ). m/s (cam at ) Stainless steel rollers, Ø mm x.3 FD 8--EX FD 8--EX.4 3 0, Nm (0,2 Nm ) 0,06 Nm (0,2 Nm ) page group 4 page group 4 Loose actuators IMPORTANT: These loose actuators can be used with items of the FD series only. Ø mm Adjustable round rod Ø 3x2 mm Adjustable square rod 3x3x2 mm Flexible rod with pointed end Adjustable actuator with technopolymer roller Adjustable fiber glass rod Ø mm Ø mm Porcelain roller Adjustable safety actuator with technopolymer roller Ø mm Article VF L3-R24 VF L3-R24 () (2) (2) VF L-R24 VF L2-R24 VF L-R24 VF L-R24 Max. speed. m/s (cam at ). m/s (cam at ). m/s (cam at ). m/s (cam at ). m/s (cam at ). m/s (cam at ) - () Actuator VF L3 can only be used in safety applications if adjusted to its max. length, as shown in figure beside. If you need an adjustable lever for safety applications, use the adjustable safety lever VF L. - (2) If installed with switch FD 8 EX (e.g. FD 8 EX, FD 68 EX ) the actuator could mechanically interfere with the housing of the switch. The interference could happen or not according to the actuator and the head fixing position. 93 -EX II 2G Ex ia IIC T6 Gb I Ex ia I Mb 2G Gb Mb Items with code code on green on green background background are stock are items stock items Accessories See page General Catalogue - 2

9 Switches compliant with ATEX directive / FD series Safety switches with separate actuator Switches with separate actuator Switches without actuator Switches with separate actuator and key release Switches without actuator Switches with manual mechanical delay 8 Switches without actuator x L FD 93--EX FD 99--EX FD R2--EX L FD 99--EX 0 N ( N ) N ( N ) 0 N ( N ) Gen. Cat. Safety page 2 page page 32 x x Actuators VF KEYF VF KEYF VF KEYF2 VF KEYF3 VF KEYF VF KEYF8 Straight actuator Angled actuator Swivelling actuator Actuator adjustable in two directions IMPORTANT: These actuators can be used with items of the FD series only (e.g. FD 93--EX). Low level coded actuators according to EN ISO 49. Actuator adjustable in one direction Universal actuator Safety switches for hinges M4 2.8 Ø4 Ø L Gen. Cat. Safety x FD 9--EX 0, Nm (0,4 Nm ) page If not expressly indicated in this chapter, for correct installation and utilization of all articles see chapter utilization requirements from page 23 to page EX II 2G Ex ia IIC T6 Gb I Ex ia I Mb 2G Gb Mb Items with code on green background are stock items Accessories See page 3 General Catalogue -

10 Safety rope switch with reset for emergency stops x x x L Gen. Cat. Safety FD 8--EX FD 83--EX FD 84--EX initial 63 N...final 83 N (90 N ) initial 4 N final 23 N (20 N ) initial 4 N final 23 N (20 N ) page - group page - group 2 page - group 2 Accessories for rope installation VF AF-TR VF AF-TR8 VF AF-MR VF AF-ME8 VF AF-ME80 VF F0-00 VF AF-IFGR03 VF AF-CA VF AF-CA0 Adjustable stay bolt Stay bolt End clamp Safety spring for longitudinal head Safety spring for transversal head Rope, Ø mm. 00 m rolls Function indicator for ropes. Text STOP Stainless steel pulley Angular pulley, stainless steel Application examples and max. rope length VF AF-TR VF AF-CA VF AF-MR VF AF-ME8 2 3 m 2 3 m 2 3 m 2 3 m 2 3 m 2 3 m m MAX VF AF-TR VF AF-CA VF AF-MR VF AF-TR VF F0 VF AF-MR 2 3 m 2 3 m 2 3 m 6 m MAX 2 m MAX VF AF-TR VF AF-CA VF AF-MR VF AF-ME80 3 m 3 m 3 m 3 m 3 m 3 m 0 m MAX VF AF-TR VF AF-CA VF AF-MR VF AF-TR VF AF-MR VF F0 3 m 3 m 3 m m MAX 3 m MAX If not expressly indicated in this chapter, for correct installation and utilization of all articles see chapter utilization requirements from page 23 to page EX II 2G Ex ia IIC T6 Gb I Ex ia I Mb 2G Gb Mb Items with code on green background are stock items Accessories See page General Catalogue - 4

11 Switches compliant with ATEX directive / FL series Technical data Housing Metal housing, baked powder coating Three threaded conduit entries: Mx. Protection degree: IP66 according to EN 29 with cable gland having equal or higher protection degree Main features Approvals: Category 2G and Metal housing, three conduit entries Protection degree IP66 Versions with gold-plated silver contacts ATEX markings and quality labels: II 2G Ex ia IIC T6 Gb I Ex ia I Mb General data Ambient temperature: - C + C Max. actuation frequency: 30 operating cycles /hour Mechanical endurance: F -EX 0 million operating cycles F 93-EX, F 8-EX, F 8 -EX, F 9-EX operating cycles Mounting position: any Safety parameters B 0d (NC contacts): F -EX,000,000 F 93-EX,F 8-EX, F 8 -EX,000,000 F 9-EX 2,00,00 Mechanical interlock, not coded: type according to EN ISO 49 Tightening torques for installation: see pages () One operation cycle means two movements, one to close and one to open contacts, as defined in EN 94. Cable cross section (flexible copper strands) Contact block : min. x 0.34 mm 2 ( x AWG ) max. 2 x. mm 2 (2 x AWG ) Contact block : min. x 0. mm 2 ( x AWG ) max. 2 x 2. mm 2 (2 x AWG 4) In conformity with standards: IEC 94--, EN 94--, EN 94-, EN 004, IEC 4-, EN 4-, EN ISO 49, EN ISO 200, IEC 29, EN 29, UL 08, CSA.2 No.4, IEC 09-0, EN 09-0, IEC 09-, EN 09-. In conformity with the requirements of: ATEX Directive 94/9/EC Low Voltage Directive 06/9/EC, Machinery Directive 06/42/EC and EMC Directive 04/08/EC. Positive contact opening in conformity with standards: IEC 94, EN 94. Installation for safety applications: Use only switches marked with the symbol aside the product code. Always connect the safety circuit to the NC contacts (normally closed contacts: -2, 2- or 3-32) as stated in standard EN 94, encl. K, par. 2. Actuate the switch at least up to the positive opening travel shown in the travel diagrams on page 238. Operate the switch at least with the positive opening force, indicated between brackets below each article, aside the minimum force value. If not expressly indicated in this chapter, for correct installation and utilization of all articles see chapter utilization requirements from page 23 to page 246. Category Zone EPL Approvals 2G Gb Mb II 2G Ex ia IIC T6 Gb I Ex ia I Mb Product code extension -EX Electrical data Maximum current ( i): 2. A Maximum voltage (Ui): Vdc Conditional short circuit current: 000 A according to EN 94 Protection against short circuits: fuse 4 A 20 V type gg Pollution degree: 3 This type of switches must be used only in intrinsic safety circuits in conformity with standard IEC 09, EN 09 For the correct utilization of the switch please use cable glands suitable for the zone according to the ATEX directive General Catalogue -

12 6 Quality marks of the product: UL approval: EAC approval: Characteristics approved by UL Utilization categories Q0 (69 VA, 2 20 Vdc) A0 ( VA, 0 Vac) Data of housing type, 4X indoor use only, 2, 3 For all contact blocks except 2 and 3 use or C copper (Cu) conductor, rigid or flexible, wire size AWG 2/4. Terminal tightening torque of. lb in (0.8 Nm). For contact blocks 2 and 3 use or C copper (Cu) conductor, rigid or flexible, wire size AWG 4. Terminal tightening torque of 2 lb in (.4 Nm). E3 RU C-IT ДМ94.В.0024 In conformity with standard: UL 08, CSA.2 No.4 Please contact our technical service for the list of approved products. Adjustable levers Overturning levers Orientable heads For switches with swivelling lever the lever can be adjusted in 0 steps over the entire 3 range. The positive movement 0 transmission is always guaranteed thanks to the particular geometrical coupling between the lever and the revolving shaft as prescribed for safety applications by the German standard BG-GSET-. For switches with swivelling lever the lever can be fastened straight or reversed, maintaining the positive coupling. This makes it possible to have two different work plans of the lever. In all switches, it is possible to rotate the head in 90 steps. Unidirectional heads For switches with swivelling lever, it is possible to select the unidirectional operation by removing the four screws of the head and revolving the internal plunger (contact block excluded). Code structure Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office. article options article FL 02-G-EX Housing FL ATEX approval metal, three conduit entries -EX II 2G Ex ia IIC T6 Gb I Ex ia I Mb 2 2, snap action 2NC, snap action 2NO, snap action, slow action 3NC, slow action 2NO+NC, slow action Actuators General Catalogue - short plunger roller lever... Threaded conduit entry Mx. Contact type silver contacts (standard) G silver contacts with µm gold coating 6

13 Switches compliant with ATEX directive / FL series With stainless steel roller on request With stainless steel roller on request R = snap action Ø0.6 Ø R L Max. speed FL 0--EX FL 0--EX FL 02--EX FL 02--EX FL 0--EX FL 0--EX FL --EX FL --EX 0. m/s 0. m/s with cam at 0. m/s with cam at 0. m/s 8 N (2 N ) 6 N (2 N ) 6 N (2 N ) 8 N (2 N ) page group page group 2 page group 2 page group With external rubber gasket Ball, Ø 2. mm, stainless steel With external rubber gasket Ø0 2.2 R L Max. speed FL --EX FL --EX FL --EX FL --EX FL 9--EX FL 9--EX FD --EX FD --EX 0. m/s with cam at 0. m/s with cam at 0. m/s m/s N (2 N ) 8 N (2 N ) 8 N (2 N ) 0.09 Nm page group page group page group page group 3 With external rubber gasket With external rubber gasket Bistable Rope switch for signalling 8 Ø.2 3. Ø R L Max. speed FL 2--EX FL 2--EX FL 2--EX FL 2--EX FL 4--EX FL --EX FL 6--EX 2NO+NC m/s m/s 0. m/s with cam at 0. m/s 0.08 Nm 0.4 Nm 0.2 Nm (0.36 Nm ) initial N - final N page group 3 page group 3 page group 4 page group 6 -EX II 2G Ex ia IIC T6 Gb I Ex ia I Mb 2G Gb Mb Accessories See page General Catalogue -

14 Position switches with revolving lever without actuator R = snap action Regular head M Compact head M IMPORTANT For safety applications: join only switches and actuators marked with symbol aside the product code. For more information about safety applications see details on page 23. R L Ø 3x x3x Ø Ø6x VF L3 VF L32 (2) VF L33 (2) () (2) Article VF L34 VF L3 VF L36 (2) Max. speed. m/s (cam at ). m/s. m/s m/s. m/s (cam at ). m/s Article (2) VF L VF L2 VF L3 VF L VF L Max. speed. m/s (cam at ). m/s (cam at ) 0. m/s. m/s (cam at ). m/s (cam at ) Stainless steel rollers, Ø mm FL 38--EX FL 38--EX FL 8--EX FL 8--EX 0, Nm (0,2 Nm ) 0,06 Nm (0,2 Nm ) page group 4 page group 4 Loose actuators IMPORTANT: These loose actuators can be used with items of the FL series only. Ø mm Adjustable round rod Ø 3x2 mm Adjustable square rod, 3x3x2 mm Flexible rod with pointed end Adjustable actuator with technopolymer roller Adjustable fiber glass rod Ø mm Ø mm Porcelain roller Adjustable safety actuator with technopolymer roller Ø mm Article VF L3-R24 VF L3-R24 () (2) (2) VF L-R24 VF L2-R24 VF L-R24 VF L-R24 Max. speed. m/s (cam at ). m/s (cam at ). m/s (cam at ). m/s (cam at ). m/s (cam at ). m/s (cam at ) - () Actuator VF L3 can only be used in safety applications if adjusted to its max. length, as shown in figure beside. If you need an adjustable lever for safety applications, use the adjustable safety lever VF L. - (2) If installed with switch FL 8 EX (e.g. FL 8 EX, FL 68 EX ) the actuator could mechanically interfere with the housing of the switch. The interference could happen or not according to the actuator and the head fixing position. 93 -EX II 2G Ex ia IIC T6 Gb I Ex ia I Mb 2G Gb Mb Items with code code on green on green background background are stock are items stock items Accessories See page General Catalogue - 8

15 Switches compliant with ATEX directive / FL series Safety switches with separate actuator Switches with separate actuator Switches without actuator L FL 93--EX 0 N ( N ) Gen. Cat. Safety page 2 Actuators VF KEYF VF KEYF VF KEYF2 VF KEYF3 VF KEYF VF KEYF8 Straight actuator Angled actuator Swivelling actuator Actuator adjustable in two directions IMPORTANT: These actuators can be used with items of the FL series only (e.g. FL 93 EX). Low level coded actuators according to EN ISO 49. Actuator adjustable in one direction Universal actuator Safety switches for hinges M4 2.8 Ø4 Ø L Gen. Cat. Safety FL 9--EX 0, Nm (0,4 Nm ) page If not expressly indicated in this chapter, for correct installation and utilization of all articles see chapter utilization requirements from page 23 to page EX II 2G Ex ia IIC T6 Gb I Ex ia I Mb 2G Gb Mb Items with code on green background are stock items Accessories See page 9 General Catalogue -

16 Safety rope switch with reset for emergency stops L Gen. Cat. Safety FL 8--EX FL 83--EX FL 84--EX initial 63 N...final 83 N (90 N ) initial 4 N final 23 N (20 N ) initial 4 N final 23 N (20 N ) page - group page - group 2 page - group 2 Accessories for rope installation VF AF-TR VF AF-TR8 VF AF-MR VF AF-ME8 VF AF-ME80 VF F0-00 VF AF-IFGR03 VF AF-CA VF AF-CA0 Adjustable stay bolt Stay bolt End clamp Safety spring for longitudinal head Safety spring for transversal head Rope, Ø mm. 00 m rolls Function indicator for ropes. Text STOP Stainless steel pulley Angular pulley, stainless steel Application examples and max. rope length VF AF-TR VF AF-CA VF AF-MR VF AF-ME8 2 3 m 2 3 m 2 3 m 2 3 m 2 3 m 2 3 m m MAX VF AF-TR VF AF-CA VF AF-MR VF AF-TR VF F0 VF AF-MR 2 3 m 2 3 m 2 3 m 6 m MAX 2 m MAX VF AF-TR VF AF-CA VF AF-MR VF AF-ME80 3 m 3 m 3 m 3 m 3 m 3 m 0 m MAX VF AF-TR VF AF-CA VF AF-MR VF AF-TR VF AF-MR VF F0 3 m 3 m 3 m m MAX 3 m MAX If not expressly indicated in this chapter, for correct installation and utilization of all articles see chapter utilization requirements from page 23 to page EX II 2G Ex ia IIC T6 Gb I Ex ia I Mb 2G Gb Mb Items with code on green background are stock items Accessories See page General Catalogue - 0

17 Switches in conformity with ATEX directive / FM series Technical data Housing Metal housing, baked powder coating One threaded conduit entry: Protection degree: Mx. IP6 according to EN 29 with cable gland having equal or higher protection degree Main features Approvals: Category 2G and Metal housing, one conduit entry Protection degree IP6 Versions with gold-plated silver contacts General data Ambient temperature: - C + C Max. actuation frequency: 30 operating cycles /hour Mechanical endurance: F -EX 0 million operating cycles F C -EX, F 96-EX operating cycles Mounting position: any Safety parameters B 0d (NC contacts): F -EX,000,000 F C -EX,000,000 F 96-EX 2,00,000 Mechanical interlock, not coded: type according to EN ISO 49 Tightening torques for installation: see pages () One operation cycle means two movements, one to close and one to open contacts, as defined in EN 94. Cable cross section (flexible copper strands) Contact block : min. x 0.34 mm 2 ( x AWG ) max. 2 x. mm 2 (2 x AWG ) Contact block : min. x 0. mm 2 ( x AWG ) max. 2 x 2. mm 2 (2 x AWG 4) ATEX markings and quality labels: II 2G Ex ia IIC T6 Gb I Ex ia I Mb In conformity with standards: IEC 94, EN 94, EN 94, EN 004, IEC 4, EN 4, EN ISO 49, EN ISO 200, IEC 29, EN 29, UL 08, CSA.2 No.4, IEC 09 0, EN 09 0, IEC 09, EN 09. In conformity with the requirements of: ATEX Directive 94/9/EC Low Voltage Directive 06/9/EC, Machinery Directive 06/42/EC and EMC Directive 04/08/EC. Positive contact opening in conformity with standards: IEC 94, EN 94. Installation for safety applications: Use only switches marked with the symbol aside the product code. Always connect the safety circuit to the NC contacts (normally closed contacts: -2, 2- or 3-32) as stated in standard EN 94, encl. K, par. 2. Actuate the switch at least up to the positive opening travel shown in the travel diagrams on page 2. Operate the switch at least with the positive opening force, indicated between brackets below each article, aside the minimum force value. If not expressly indicated in this chapter, for correct installation and utilization of all articles see chapter utilization requirements from page 23 to page 246. Category Zone EPL Approvals 2G Gb Mb II 2G Ex ia IIC T6 Gb I Ex ia I Mb Product code extension -EX Electrical data Maximum current ( i): 2. A Maximum voltage (Ui): Vdc Conditional short circuit current: 000 A according to EN 94 Protection against short circuits: fuse 4 A 20 V type gg Pollution degree: 3 This type of switches must be used only in intrinsic safety circuits in conformity with standard IEC 09, EN 09 For the correct utilization of the switch use cable glands suitable for the zone according to the ATEX directive General Catalogue -

18 Quality marks of the product: UL approval: E3 EAC approval: RU C-IT ДМ94.В.0024 Characteristics approved by UL Utilization categories Q0 (69 VA, 2 20 Vdc) A0 ( VA, 0 Vac) Data of housing type, 4X indoor use only, 2, 3 For all contact blocks except 2 and 3 use or C copper (Cu) conductor, rigid or flexible, wire size AWG 2/4. Terminal tightening torque of. lb in (0.8 Nm). For contact blocks 2 and 3 use or C copper (Cu) conductor, rigid or flexible, wire size AWG 4. Terminal tightening torque of 2 lb in (.4 Nm). In conformity with standard: UL 08, CSA.2 No.4 Please contact our technical service for the list of approved products. Adjustable levers In the switches it is possible to adjust the lever with 0 steps for the whole 3 range. The positive movement transmission is always guaranteed thanks to the particular geometrical coupling between the lever and the revolving shaft as prescribed for safety applications by the German standard BG-GS-ET-. 0 Overturning levers In the switches, the lever can be fastened straight or reversed, maintaining the positive coupling. This makes it possible to have two different work plans of the lever. Orientable heads In all switches, it is possible to rotate the head in 90 steps. Code structure Housing FM metal, one conduit entry, snap action 2NC, snap action 2 2NO, snap action, slow action 2 3NC, slow action 2NO+NC, slow action Actuators 0 short plunger 02 roller lever Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office. article options article F02-G-EX ATEX approval -EX Threaded conduit entry Contact type G Mx. II 2G Ex ia IIC T6 Gb I Ex ia I Mb silver contacts (standard) silver contacts with µm gold coating General Catalogue - 2

19 Switches in conformity with ATEX directive / FM series R = snap action With stainless steel roller on request With stainless steel roller on request 32(29-3) ( - 23) R L Max. speed x F0--EX FM 0--EX x F02--EX FM 02--EX x F0--EX FM 0--EX x.2 F0--EX FM 0--EX m/s 0. m/s with cam at 0. m/s with cam at 0. m/s with cam at 8 N (2 N ) 6 N (2 N ) 6 N (2 N ) 4 N (2 N ) page 2 - group page 2 - group 2 page 2 - group 2 page 2 - group 3 With external rubber gasket R L Max. speed Ø 0 4.2x F08--EX FM 08--EX 0. m/s 8 N (2 N ) Mx 4.2x.2 F2--EX FM 2--EX m/s 8 N (2 N ) M x 4.2x.2 F3--EX FM 3--EX m/s with cam at 8 N (2 N ) x.2 F-R-EX FM -R-EX m/s with cam at 8 N (2 N ) page 2 - group page 2 - group page 2 - group page 2 - group 3.8 With external rubber gasket With external rubber gasket With external rubber gasket Rope switch for signalling R L Max. speed x.2 Ø F--EX FM --EX m/s 0.06 Nm x F2--EX FM 2--EX m/s 0.04 Nm Ø x F2--EX FM 2--EX m/s 0. Nm Ø x F6--EX FM 6--EX 2NO+NC 0. m/s initial N - final N page 2 - group 4 page 2 - group 4 page 2 - group 4 page 2 - group -EX II 2G Ex ia IIC T6 Gb I Ex ia I Mb 2G Gb Mb Accessories See page 3 General Catalogue -

20 Position switches with revolving lever without actuator IMPORTANT For safety applications: join R = snap action only switches and actuators marked with symbol aside.9 the product code. For more information about safety applications see details on page M 4 4.2x R L F38--EX FM 38--EX 0,06 Nm (0,2 Nm ) page 2 - group Loose actuators IMPORTANT: These loose actuators can be used with items of the FM series only. Roller, Ø mm Roller, Ø mm Adjustable square rod, 3x3x2 mm Flexible rod with pointed end Adjustable round rod Ø 3x2 mm Ø mm x3x Ø 3x M Ø 9 M M 4 M 4 0 M 4 0 Ø6x0 0 M 4 M 4 M 4 M 4 M 4 M 4 M Article VF LE VF LE3 VF LE33 VF LE34 VF LE0 VF LE Max. speed. m/s (cam at ). m/s (cam at ). m/s. m/s. m/s. m/s (cam at ) Ø mm Porcelain roller Ø mm Adjustable actuator with technopolymer roller Adjustable safety actuator with technopolymer roller Ø mm Adjustable fiber glass rod M Article () VF LE2 VF LE3 VF LE4 VF LE VF LE VF LE VF LE69 Max. speed. m/s (cam at ) 0. ms. m/s (cam at ). m/s (cam at ). m/s (cam at ). m/s (cam at ). m/s Stainless steel rollers, Ø mm M 4 M 4 49 M 4 3. M 4 M 4 M 4 M 4 Article () VF LE3-R24 VF LE-R24 VF LE2-R24 VF LE4-R24 VF LE-R24 VF LE-R24 VF LE-R24 Max. speed. m/s (cam at ). m/s (cam at ). m/s (cam at ). m/s (cam at ). m/s (cam at ). m/s (cam at ). m/s (cam at ) - () Actuator VF LE can only be used in safety applications if adjusted to its max. length, as shown in figure beside. If you need an adjustable lever for safety applications, use the adjustable safety lever VF LE. 93 -EX II 2G Ex ia IIC T6 Gb I Ex ia I Mb 2G Gb Mb Items with code on green background are stock items Accessories See page General Catalogue - 4

21 Switches in conformity with ATEX directive / FM series Safety switches with slotted hole lever L x N ( N ) N ( N ) N ( N ) page group 0 page group page group 0 4.2x x FM C--EX FM C2--EX FM C3--EX Application examples Safety switches for hinges Application examples.2 Ø 2.2 M x L FM 96--EX 0, Nm (0,4 Nm ) page group 9 If not expressly indicated in this chapter, for correct installation and utilization of all articles see chapter utilization requirements from page 23 to page EX II 2G Ex ia IIC T6 Gb I Ex ia I Mb 2G Gb Mb Accessories See page General Catalogue -

22 Notes General Catalogue -

23 Switches compliant with ATEX directive / FD series Technical data Housing Metal housing, baked powder coating One threaded conduit entry: Protection degree: Mx. IP66 according to EN 29 with cable gland having equal or higher protection degree Main features Approvals: 2D category Metal housing, one conduit entry Protection degree IP66 Versions with gold-plated silver contacts ATEX markings and quality labels: II 2D Ex tb IIIC T80 C Db General data Ambient temperature: - C +0 C Max. actuation frequency: 30 operating cycles /hour Mechanical endurance: F -EX 0 million operating cycles F 93-EX, F 8-EX, F 8 -EX, F 9-EX operating cycles F 99-EX, F R2-EX operating cycles Mounting position: any Safety parameters B 0d (NC contacts): F -EX,000,000 F 93-EX,F 8-EX, F 8 -EX,000,000 F 99-EX, F R2-EX 00,000 F 9-EX 2,00,00 Mechanical interlock, not coded: type according to EN ISO 49 Tightening torques for installation: see pages () One operation cycle means two movements, one to close and one to open contacts, as defined in EN 94. Cable cross section (flexible copper strands),: min. x 0.34 mm 2 ( x AWG ) max. 2 x. mm 2 (2 x AWG ) Contact block : min. x 0. mm 2 ( x AWG ) max. 2 x 2. mm 2 (2 x AWG 4) In conformity with standards: IEC 94, EN 94, EN 94, EN 004, IEC 4, EN 4, EN ISO 49, EN ISO 200, IEC 29, EN 29, UL 08, CSA.2 No.4, IEC 09 0, EN 09 0, IEC 09 3, EN In conformity with the requirements of: ATEX Directive 94/9/EC Low Voltage Directive 06/9/EC, Machinery Directive 06/42/EC and EMC Directive 04/08/EC. Positive contact opening in conformity with standards: IEC 94, EN 94. Installation for safety applications: Use only switches marked with the symbol aside the product code. Always connect the safety circuit to the NC contacts (normally closed contacts: -2, 2- or 3-32) as stated in standard EN 94, encl. K, par. 2. Actuate the switch at least up to the positive opening travel shown in the travel diagrams on page 238. Operate the switch at least with the positive opening force, indicated between brackets below each article, aside the minimum force value. If not expressly indicated in this chapter, for correct installation and utilization of all articles see chapter utilization requirements from page 23 to page 246. Category Zone EPL Approvals Product code extension 2D 2 Db II 2D Ex tb IIIC T80 C Db -EX8 Electrical data Thermal current (Ith): 6 A Rated insulation voltage (Ui): 20 Vac/Vdc Conditional short circuit current: 000 A according to EN 94 Protection against short circuits: type am fuse 6 A 00 V Pollution degree: 3 Utilization category Alternating current: AC (0 Hz) Ue (V) 20 Ie (A) 6 Direct current: DC3 Ue (V) Ie (A) For the correct utilization of the switch please use cable glands suitable for the zone according to the ATEX directive General Catalogue -

24 6 Quality marks of the product: UL approval: EAC approval: Characteristics approved by UL Utilization categories Q0 (69 VA, 2 20 Vdc) A0 ( VA, 0 Vac) Data of housing type, 4X indoor use only, 2, 3 For all contact blocks except 2 and 3 use or C copper (Cu) conductor, rigid or flexible, wire size AWG 2/4. Terminal tightening torque of. lb in (0.8 Nm). For contact blocks 2 and 3 use or C copper (Cu) conductor, rigid or flexible, wire size AWG 4. Terminal tightening torque of 2 lb in (.4 Nm). E3 RU C-IT ДМ94.В.0024 In conformity with standard: UL 08, CSA.2 No.4 Please contact our technical service for the list of approved products. Adjustable levers Overturning levers Orientable heads In the switches it is possible to adjust the lever with 0 steps for the whole 3 range. The positive movement transmission is always guaran0 teed thanks to the particular geometrical coupling between the lever and the revolving shaft as prescribed for safety applications by the German standard BG-GS-ET-. In the switches, the lever can be fastened straight or reversed, maintaining the positive coupling. This makes it possible to have two different work plans of the lever. In all switches, it is possible to rotate the head in 90 steps. Unidirectional heads For switches with swivelling lever, it is possible to select the unidirectional operation by removing the four screws of the head and revolving the internal plunger. Code structure Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office. article options article FD 02-G-EX8 Housing FD ATEX approval -EX8 metal, one conduit entry II 2D Ex tb IIIC T80 C Db 0 2, snap action 2NO, slow action 2NC, snap action, slow action 3NC, slow action 2NO+NC, slow action Threaded conduit entry Mx. Contact type Actuators General Catalogue - short plunger roller lever... silver contacts (standard) G silver contacts with µm gold coating

25 Switches compliant with ATEX directive / FD series With stainless steel roller on request With stainless steel roller on request R = snap action Ø0 Ø R L Ø Max. speed x.3 FD 0--EX8 FD 0--EX8.4 3 x.3 FD 02--EX8 FD 02--EX8.4 3 x.3 FD 0--EX8 FD 0--EX8.4 3 x.3 FD --EX8 FD --EX8 0. m/s 0. m/s with cam at 0. m/s with cam at 0. m/s 8 N (2 N ) 6 N (2 N ) 6 N (2 N ) 8 N (2 N ) page group page group 2 page group 2 page group.4 3 Ball, Ø 2. mm, stainless steel Bistable Rope switch for signalling 24 R L Max. speed x.3 FD --EX8 FD --EX m/s with cam at 8 N (2 N ) x.3 FD 9--EX8 FD 9--EX8 0. m/s 8 N (2 N ).4 3 x x FD 4--EX8 FD --EX8 0. m/s with cam at 0.2 Nm (0.36 Nm ) FD 6--EX8 0. m/s initial N - final N page group page group page group 4 page group 6 -EX8 II 2D Ex tb IIIC T80 C Db 2D 2 Db Accessories See page 9 General Catalogue -

26 Position switches with revolving lever without actuator R = snap action Regular head M Compact head M IMPORTANT For safety applications: join only switches and actuators marked with symbol aside the product code. For more information about safety applications see details on page 23. R L x.3 FD 38--EX8 FD 38--EX Ø 3x x3x Ø Ø6x VF L3 VF L32 (2) VF L33 (2) () (2) Article VF L34 VF L3 VF L36 (2) Max. speed. m/s (cam at ). m/s. m/s m/s. m/s (cam at ). m/s Article (2) VF L VF L2 VF L3 VF L VF L Max. speed. m/s (cam at ). m/s (cam at ) 0. m/s. m/s (cam at ). m/s (cam at ) Stainless steel rollers, Ø mm x.3 FD 8--EX8 FD 8--EX , Nm (0,2 Nm ) 0,06 Nm (0,2 Nm ) page group 4 page group 4 Loose actuators IMPORTANT: These loose actuators can be used with items of the FD series only. Ø mm Adjustable round rod Ø 3x2 mm Adjustable square rod 3x3x2 mm Flexible rod with pointed end Adjustable actuator with technopolymer roller Adjustable fiber glass rod Ø mm Ø mm Porcelain roller Adjustable safety actuator with technopolymer roller Ø mm Article VF L3-R24 VF L3-R24 () (2) (2) VF L-R24 VF L2-R24 VF L-R24 VF L-R24 Max. speed. m/s (cam at ). m/s (cam at ). m/s (cam at ). m/s (cam at ). m/s (cam at ). m/s (cam at ) - () Actuator VF L3 can only be used in safety applications if adjusted to its max. length, as shown in figure beside. If you need an adjustable lever for safety applications, use the adjustable safety lever VF L. - (2) If installed with switch FD 8 EX8 (e.g. FD 8 EX8, FD 68 EX8 ) the actuator could mechanically interfere with the housing of the switch. The interference could happen or not according to the actuator and the head fixing position. 93 -EX8 II 2D Ex tb IIIC T80 C Db 2D 2 Db Items with code on green background are stock items Accessories See page General Catalogue - 0

27 Switches compliant with ATEX directive / FD series Safety switches with separate actuator Switches with separate actuator Switches without actuator Switches with separate actuator and key release Switches without actuator Switches with manual mechanical delay 8 Switches without actuator L L x N ( N ) N ( N ) 0 N ( N ) Gen. Cat. Safety page 2 page page 32 x.3 FD 93--EX8 FD 99--EX8 FD 99--EX8.4 3 x.3 FD R2--EX8.4 3 Actuators VF KEYF VF KEYF VF KEYF2 VF KEYF3 VF KEYF VF KEYF8 Straight actuator Angled actuator Swivelling actuator Actuator adjustable in two directions IMPORTANT: These actuators can be used with items of the FD series only (e.g. FD 93 EX8). Low level coded actuators according to EN ISO 49. Actuator adjustable in one direction Universal actuator Safety switches for hinges M4 2.8 Ø4 Ø L Gen. Cat. Safety x FD 9--EX8 0, Nm (0,4 Nm ) page If not expressly indicated in this chapter, for correct installation and utilization of all articles see chapter utilization requirements from page 23 to page EX8 II 2D Ex tb IIIC T80 C Db 2D 2 Db Items with code on green background are stock items Accessories See page General Catalogue -

28 Safety rope switch with reset for emergency stops L L Gen. Cat. Safety x.3 FD 8--EX8 FD 8--EX8.4 3 FD 83--EX8 FD 83--EX8 x x.3 FD 84--EX8 FD 84--EX8.4 3 initial 63 N...final 83 N (90 N ) initial 4 N final 23 N (20 N ) initial 4 N final 23 N (20 N ) page - group page - group 2 page - group 2 Accessories for rope installation VF AF-TR VF AF-TR8 VF AF-MR VF AF-ME8 VF AF-ME80 VF F0-00 VF AF-IFGR03 VF AF-CA VF AF-CA0 Adjustable stay bolt Stay bolt End clamp Safety spring for longitudinal head Safety spring for transversal head Rope, Ø mm. 00 m rolls Function indicator for ropes. Text STOP Stainless steel pulley Angular pulley, stainless steel Application examples and max. rope length VF AF-TR VF AF-CA VF AF-MR VF AF-ME8 2 3 m 2 3 m 2 3 m 2 3 m 2 3 m 2 3 m m MAX VF AF-TR VF AF-CA VF AF-MR VF AF-TR VF F0 VF AF-MR 2 3 m 2 3 m 2 3 m 6 m MAX 2 m MAX VF AF-TR VF AF-CA VF AF-MR VF AF-ME80 3 m 3 m 3 m 3 m 3 m 3 m 0 m MAX VF AF-TR VF AF-CA VF AF-MR VF AF-TR VF AF-MR VF F0 3 m 3 m 3 m m MAX 3 m MAX If not expressly indicated in this chapter, for correct installation and utilization of all articles see chapter utilization requirements from page 23 to page EX8 II 2D Ex tb IIIC T80 C Db 2D 2 Db Items with code on green background are stock items Accessories See page General Catalogue - 2

29 Switches compliant with ATEX directive / FL series Technical data Housing Metal housing, baked powder coating Three threaded conduit entries: Protection degree: Mx. IP66 according to EN 29 with cable gland having equal or higher protection degree Main features Approvals: 2D category Metal housing, three conduit entries Protection degree IP66 Versions with gold-plated silver contacts ATEX markings and quality labels: II 2D Ex tb IIIC T80 C Db certification in progress General data Ambient temperature: - C +0 C Max. actuation frequency: 30 operating cycles /hour Mechanical endurance: F -EX 0 million operating cycles F 93-EX, F 8-EX, F 8 -EX, F 9-EX operating cycles Mounting position: any Safety parameters B 0d (NC contacts): F -EX,000,000 F 93-EX,F 8-EX, F 8 -EX,000,000 F 9-EX 2,00,00 Mechanical interlock, not coded: type according to EN ISO 49 Tightening torques for installation: see pages () One operation cycle means two movements, one to close and one to open contacts, as defined in EN 94. Cable cross section (flexible copper strands) Contact block : min. x 0.34 mm 2 ( x AWG ) max. 2 x. mm 2 (2 x AWG ) Contact block : min. x 0. mm 2 ( x AWG ) max. 2 x 2. mm 2 (2 x AWG 4) In conformity with standards: IEC 94, EN 94, EN 94, EN 004, IEC 4, EN 4, EN ISO 49, EN ISO 200, IEC 29, EN 29, UL 08, CSA.2 No.4, IEC 09 0, EN 09 0, IEC 09 3, EN In conformity with the requirements of: ATEX Directive 94/9/EC Low Voltage Directive 06/9/EC, Machinery Directive 06/42/EC and EMC Directive 04/08/EC. Positive contact opening in conformity with standards: IEC 94, EN 94. Installation for safety applications: Use only switches marked with the symbol aside the product code. Always connect the safety circuit to the NC contacts (normally closed contacts: -2, 2- or 3-32) as stated in standard EN 94, encl. K, par. 2. Actuate the switch at least up to the positive opening travel shown in the travel diagrams on page 238. Operate the switch at least with the positive opening force, indicated between brackets below each article, aside the minimum force value. If not expressly indicated in this chapter, for correct installation and utilization of all articles see chapter utilization requirements from page 23 to page 246. Category Zone EPL Approvals Product code extension 2D 2 Db II 2D Ex tb IIIC T80 C Db -EX8 Electrical data Thermal current (Ith): 6 A Rated insulation voltage (Ui): 20 Vac/Vdc Conditional short circuit current: 000 A according to EN 94 Protection against short circuits: type am fuse 6 A 00 V Pollution degree: 3 Utilization category Alternating current: AC (0 Hz) Ue (V) 20 Ie (A) 6 Direct current: DC3 Ue (V) Ie (A) For the correct utilization of the switch please use cable glands suitable for the zone according to the ATEX directive 3 General Catalogue -

UL HAZARDOUS LOCATIONS SERVICES

UL HAZARDOUS LOCATIONS SERVICES UL HAZARDOUS LOCATIONS SERVICES The international preference in hazardous locations certification for over 100 years ul.com/hazloc Explosive Gas Atmospheres Class I Division S Includes flammable gases,

More information

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas

More information

Guide for hazardous areas

Guide for hazardous areas Guide for hazardous areas 1 Hazardous areas definitions 2 Gas and dust s 3 Temperature classifications 4 Common flammable gases, vapours and dust types 5 Protection concepts ATEX and IECEx 6 Protection

More information

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The entrepreneurial basis of the R. STAHL Technology Group follows a long tradition. The product range is aimed at specialised

More information

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or

More information

ATEX, NOMENCLATURE AND CODING

ATEX, NOMENCLATURE AND CODING Technical Notes ATEX, NOMENCLATURE AND CODING The intent of this technical note is approach to the user to the ATEX normative. For this we will begin defining, what is an explosive atmosphere, what are

More information

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white . TECHNICAL DATA LIGHT FITTING REFLECTOR Polycarbonate tube of 4 mm. thickness Laquered steel painted white END CAPS Aluminium 2030 (polyester paint RAL 7047) POWER SOURCE LAMP TYPE 220-240V, 50/60Hz T8

More information

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE DANISH TECHNOLOGICAL INSTITUTE The Danish Technological Institute is a self-owned and not-f-profit institution. We develop, apply and disseminate research- and technologically-based knowledge f the Danish

More information

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt Airo Wireless Intrinsically Safe White Paper Written By: David Schmitt Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection certification for safe operation with electronic

More information

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres Quick Introduction to: DANISH TECHNOLOGICAL INSTITUTE The Danish Technological Institute is a self-owned and not-fprofit institution. We develop, apply and disseminate research- and technologically-based

More information

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE PUE HX5.EX explosion-proof hazardous area indicator ATEX APPROVAL PUE HX5.EX is a cutting-edge weighing indicator, designed to

More information

ATEX, NOMENCLATURE AND CODING

ATEX, NOMENCLATURE AND CODING ATEX, NOMENCLATURE AND CODING The intent of this technical note is approach to the user to the ATEX normative. For this we will begin defining, what is an explosive atmosphere, what are ATEX, as well as

More information

Beamex Calibration White Paper. Calibration in hazardous areas

Beamex Calibration White Paper.  Calibration in hazardous areas Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following

More information

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0. Selection of Explosion Protected Equipment for Hazardous Locations Compiled by: Pieter Coetzee ZONE 2 ZONE 0 ZONE 1 Be safe be Ex Contents Introduction Occupational Health and Safety Act. (Act 85 of 1993)

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT

More information

Beamex. Calibration White Paper. Calibration in hazardous areas

Beamex. Calibration White Paper.   Calibration in hazardous areas Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous

More information

ATEX Safety Switches. More than safety.

ATEX Safety Switches. More than safety. ATEX Safety Switches More than safety. AUDIN - 8, avenue de la malle - 5370 Saint Brice Courcelles Tel : 03.6.0.0. - Fax : 03.6.0.8.0 - Web : http: www.audin.fr - Email : info@audin.fr ATEX products from

More information

1. GENERAL TECHNICAL INFORMATION

1. GENERAL TECHNICAL INFORMATION 1. GENERAL TECHNICAL INFORMATION 1.1 EXPLOSIVE ATMOSPHERES: Every time that dangerous quantities and concentration of flammable gas, vapors mixture or dust clouds exists, risk of explosions may arise.

More information

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors Drive Technology \ Drive Automation \ System Integration \ Services *23511257_0817* Inquiry Forms for Explosion-Proof Gearmotors Edition 08/2017 23511257/EN SEW-EURODRIVE Driving the world Inquiry forms

More information

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62. 637 PHOTO PHOTO Flameproof Type Curtain Type 4 General terms and conditions... F-7 Related Information Glossary of terms... P.1455~ Sensor selection guide... P.497~ General precautions... P.1458~ Conforming

More information

Overview of Hazardous Locations as They Relate to Solenoid Valves

Overview of Hazardous Locations as They Relate to Solenoid Valves Overview of Hazardous Locations as They Relate to Solenoid Valves Defined: Hazardous Location - "where fire or explosion hazards may exist due to flammable gases or vapors, flammable liquids, combustible

More information

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global 597 Flameproof Type Light Curtain Type 4 General terms and conditions... F-3 Related Information guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P.1595 PHOTO PHOTO Certified

More information

ATM Lighting sp. z o.o

ATM Lighting sp. z o.o INSTALLATION AND MAINTENANCE MANUAL FOR EXPLOSIONPROOF LIGHT FITTING EXL210LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk,

More information

VSD AND SS DRIVING ATEX MOTORS February 2014

VSD AND SS DRIVING ATEX MOTORS February 2014 VSD AND SS DRIVING ATEX MOTORS February 2014 1 Introduction to ATEX 2 ATEX motor designation 3 VSD Sample Solutions 4 SS descriptions Introduction to ATEX EU territory define the use of electrical equipment

More information

Flameproof Type Light Curtain Type 4

Flameproof Type Light Curtain Type 4 545 PHOTO PHOTO Flameproof Type Curtain Type 4 Sensor selection guide...p.11~ / P.479~ General terms and conditions... P.1 SF4-AH... P.569 ~ Glossary of terms / General precautions... P.983 ~ / P.986 ~

More information

Explosion-protected actuator Page 259 of 292

Explosion-protected actuator Page 259 of 292 Explosion-protected actuator Page 259 of 292 9.5 Explosion-protected actuator 9.5.1. What is an explosion? A flammable substance and oxygen, in a certain mixture, must be available to set off an explosion.

More information

Electrical Installations Design, Selection, Erection and Inspection

Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2018 Jakarta, Indonesia Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2018 Jakarta, Indonesia Peter Thurnherr thuba Ltd.,

More information

ATM Lighting sp. z o.o

ATM Lighting sp. z o.o INSTALLATION AND MAINTENANCE MANUAL FOR EXPLOSIONPROOF LIGHT FITTING EXL390LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk,

More information

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS For a print friendly page click here INTRODUCTION Hazardous areas are those in which there exists a risk of explosion

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 8 mm non-flush Stainless steel housing Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 8 mm

More information

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING

More information

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218 CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output

More information

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket

More information

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories Hazardous Locations: Understanding the Basics of Global Compliance Requirements Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories DISCLAIMER/ TERMS OF USE: THE INFORMATION

More information

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here. A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here Introduction Potentially Explosive Atmospheres exist where there is a risk

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 5 mm flush Usable up to SIL2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching element

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 15 mm Installation non-flush Assured operating distance s a 0...

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 50 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 50 mm Installation non-flush Output polarity NAMUR

More information

Guide to Hazardous Location Approvals:

Guide to Hazardous Location Approvals: Selection Guide Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches Introduction There are many considerations when selecting a switch to be used in hazardous areas. In addition

More information

Equipment and Solutions

Equipment and Solutions Equipment and Solutions Solution [formally technor atex] Subject to errors or changes Editing completed January 2016 Ex-tech Group is located at Forus in Stavanger, Norway, one of the world s top Centers

More information

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches A Selection Guide Introduction There are many considerations when selecting a switch to be used in hazardous areas. In

More information

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing

More information

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG05D-SIL is a flameproof beacon which is certified

More information

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY Cell Phones Smartphones PDA integrating people, products and processes Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection

More information

MICROpeL 75 Combustible Gas Sensor Part Number: PM

MICROpeL 75 Combustible Gas Sensor Part Number: PM MICROpeL 75 Combustible Gas Sensor Part Number: PM759-000 Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance Reduced

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

Dual certification! Air handling units for potentially explosive atmospheres

Dual certification! Air handling units for potentially explosive atmospheres Dual certification! Air handling units for potentially explosive atmospheres X-CUBE Ex A certified safety product The air handling unit with dual ATEX certification ATEX directive 2014/34/EU applies to

More information

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0 Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:

More information

Fire Alarm System Accessories

Fire Alarm System Accessories UL, ULC Approved* Fire Alarm System Accessories Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer isolated barrier

More information

S T R I T T & P R I E B E I N C.

S T R I T T & P R I E B E I N C. Equipment Enclosure Comparisons Type of Enclosure European - Area of use Designation Standard IEC - Area of use Designation Standard USA - Area of use Designation Standard Flameproof Enclosure An enclosure

More information

Relays for use in hazardous locations. Class I, Division 2 and ATEX

Relays for use in hazardous locations. Class I, Division 2 and ATEX Relays for use in hazardous locations Class I, Division 2 and ATEX Explosion protection in North America azardous (classified) locations, as defined in the National Electric Code (NEC), are locations where

More information

standards: standards:

standards: standards: INSTRUCTION MANUAL D2xB1LD2 LED Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING HAZARD

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm

More information

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC Quick Introduction to TÛV Denmark TÜV Denmark - is a part of the TÜV NORD Group a global Organisation f Certification and Inspection of: Quality Management Systems, Products, Processes and Qualification

More information

Implementation of ATEX Guidelines

Implementation of ATEX Guidelines Implementation of ATEX Guidelines Temperature and Climatic Test Chambers for Usage under Conditions Carrying a Risk of Fire and Explosion What are ATEX guidelines? Introduction Duties of the system user...

More information

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236 CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

Fire Alarm System Accessories

Fire Alarm System Accessories Approved by APPROVED Fire Alarm System Accessories FM Approved* Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer

More information

OPTIWAVE X500 Supplementary Instructions

OPTIWAVE X500 Supplementary Instructions OPTIWAVE X500 Supplementary Instructions OPTIWAVE 3500 C OPTIWAVE 6500 C OPTIWAVE 7500 C Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE X500 1 General safety information 4 1.1

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Accessories BF 12 Mounting flange, 12 mm Technical Data specifications Switching element function NAMUR, NO Rated operating distance s n 4 mm Installation non-flush

More information

Hazardous area descriptions

Hazardous area descriptions Hazardous area descriptions National Electrical Code (NEC) 500 Traditional standards used in North America. Example: Class I, Div 1, Group B, C, D, T4 Permitted Class Permitted Division Permitted Group

More information

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required) FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators EC-Type Examination Certificate TÜV99 ATEX 1479X Accessories BT32 BT32XS BT32XAS BT33 BT34 V1-G-N4-5M-PUR Female cordset, M12, 4-pin, NAMUR,

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-nA Edition 08/207 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN ZONES 1,21 & 2,22 KDB 15ATEX0049X NEW

EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN ZONES 1,21 & 2,22 KDB 15ATEX0049X NEW EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN S 1,21 & 2,22 KDB 150049X NEW WORK WITH GDANSK / Poland ABOUT US ATM Lighting is a Polish manufacturer of technical light fittings for various industry sectors.

More information

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations synchronization requirements of UL1971 & UL1638 / CAN/ULCS526. 2.2 NEC & CEC Class / Division Ratings for US / Canada

More information

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 8310 IR Detection of flammable gases and vapour Dräger Polytron 8310 IR Detection of flammable gases and vapour The Dräger Polytron 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

5 m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NBMX-21-05

5 m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NBMX-21-05 Explosion proof Non-contact Safety Switches Explosion proof reed non-contact switches monitor the status of guarding doors in petro-chemical and food applications with explosive atmospheres. Based on reed

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate IECEx

More information

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,

More information

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper How Limit and Basic Switches Can Stop Machines from Going Boom White Paper sensing.honeywell.com 2 Abstract In hazardous

More information

manual addendum DELPHI Ex

manual addendum DELPHI Ex manual addendum DELPHI Ex II 2G Ex eb IIC T4 Gb II 2D Ex tb IIIC T135 C IP65 Db Tamb=-20 +40 C Reference list: Norm (last issue) Title Dir. 2014/34/UE EN 60079-31 EN60079-0 EN60079-7 Equipment and Protective

More information

THE BELGIAN PIONEER IN GAS DETECTION

THE BELGIAN PIONEER IN GAS DETECTION DAT 420 Gas or oxygen detector INSTRUCTION MANUAL THE BELGIAN PIONEER IN GAS DETECTION Copyright 2016 by DALEMANS s.a. Revision V1R7 07/2016 Any reproduction, whether partial or entire, made of this document,

More information

ATEX - ATmosphere EXplosive

ATEX - ATmosphere EXplosive ATEX - ATmosphere EXplosive 153 DIRECTIVE 94/9/CE (ATEX= ATMOSPHERE EXPLOSIVE) OF THE EUROPEAN PARLIAMENT AND COUNCIL (MARCH 23, 1994): IMPACT ON LIGHTING FIXTURES APPLICATIONS Polycarbonate and steel

More information

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor Product ID Type # Product # Drawing # DSF 1210.00 SHV Ex-atex (2m) 374Z-05066 110428F1 DSF 1210.00 SHV Ex-atex (5m) 374Z-05176 110428F1 DSF 1210.00 SHV Ex-atex (10m) 374Z-05590 110428F1 DSF 1410.00 SHV

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG15E and BExBG10E Flameproof / Increased Safety Xenon Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG15E and BExBG10E beacons are flameproof

More information

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The

More information

4) Intrinsic Safety Certification

4) Intrinsic Safety Certification INSTRUCTION MANUAL Minialert Intrinsically Safe Round Combined Unit Section Volume Control Tone Generator S2 S3 Tone Selection Switches Fig 1 Simplified block diagram The combined unit is CE marked for

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY

More information

CLASS I LOCATIONS ZONE CLASSIFICATION

CLASS I LOCATIONS ZONE CLASSIFICATION HAZARDOUS (CLASSIFIED) LOCATIONS Hazardous locations are those locations where the risk of a fire or explosion may exist due to the presence of flammable gases or vapors, flammable liquids, combustible

More information

Operating Manual MS220KA and MSR220KA

Operating Manual MS220KA and MSR220KA Temperature Relays and MINIKA, Mains Monitoring, Digital Panel meters MINIPAN, Switching Relays and Controls Operating Manual MS220KA and MSR220KA ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße

More information

OPTIBAR P 1010/2010 C Supplementary instructions

OPTIBAR P 1010/2010 C Supplementary instructions OPTIBAR P 1010/2010 C Supplementary instructions Pressure transmitter Equipment category II 1G / Ga, II 1D / Da in protection type intrinsic safety Exi KROHNE CONTENTS OPTIBAR P 1010/2010 C 1 Safety instructions

More information

Explosion-proof Immersion Heater Type D-8660

Explosion-proof Immersion Heater Type D-8660 Explosion-proof Immersion Heater Type D-8660 Sinus Jevi has developed explosionproof Ex de heating equipment, for hazardous area. The flame-proof (d) enclosures have been designed for non save areas to

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...

More information

Guide to Intrinsically Safe Portable Radios

Guide to Intrinsically Safe Portable Radios Guide to Intrinsically Safe Portable Radios An overview of common IS standards www.taitradio.com GUIDE TO INTRINSICALLY SAFE PORTABLE RADIOS SUMMARY The development of equipment for explosive atmospheres

More information

Frequently Asked Questions

Frequently Asked Questions aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Frequently Asked Questions ATEX Solenoid Valves Table of Content 1.

More information

Meets Global Standards

Meets Global Standards No.CP-PC-6E Explosion-Proof Switches Compliant IEC Standards Vertical Explosion-Proof Switches L X7000 Series -Point Detection Explosion-Proof Switches VCX-7000 Series Ex d e C T6 certified Meets Global

More information

SENSORS CATALOGUE TEMPERATURE MEASUREMENT IN INDUSTRIAL ENVIRONMENTS

SENSORS CATALOGUE TEMPERATURE MEASUREMENT IN INDUSTRIAL ENVIRONMENTS SENSORS CATALOGUE TEMPERATURE MEASUREMENT IN INDUSTRIAL ENVIRONMENTS SENSORS FOR EXPLOSIVE ATMOSPHERES 174 SENSORS CATALOGUE WWW.PYROCONTROLE.COM REMINDERS CONCERNING THE ATEX DIRECTIVE 176 PRESSURE EQUIPMENT

More information

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm 0102 Model Number Features 8 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Integrated Solutions Low Voltage Systems

Integrated Solutions Low Voltage Systems Integrated Solutions Low Voltage Systems 612 Contents Energy Distribution Overview Module Technology 8146 614 Overview Flameproof Enclosures 8220 614 Overview Flameproof Enclosures 8261 614 Overview CUBEx

More information

ESSENTIAL EXPLOSION PROTECTION

ESSENTIAL EXPLOSION PROTECTION ESSENTIAL EXPLOSION PROTECTION 2 3 FOREWORD In many industries, gases, vapours, mist and dust develop and escape in the course of manufacturing, processing, transporting and storing combustible substances.

More information

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS 3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition proof assemblies, where,

More information

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExS110D-SIL Flameproof Sounders For use in Flammable Gas Atmospheres BExS110D-SIL 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN

More information