Models 65, F65, 150 & F150

Size: px
Start display at page:

Download "Models 65, F65, 150 & F150"

Transcription

1 Models 65, F65, 50 & F50 Purgemeters Customer Value Proposition: Porter variable area flowmeters include 65mm and 50mm scale length tube assemblies and are available in either forged body or side-plate construction. Forged body models feature a wrap-around window for full 80 tube visibility and an attractive forged one-piece bacl anodized aluminum body. Side-plate constructed models are conveniently interchangeable with competitive designs. Porter control valves, including the exclusive Torque Guard cartridge, can be added to either style flowmeter for precise flow indication and control in one economical unit. Multi-tube side-plate models, ranging from two to six tubes, are available with or without control valves and can include individual inlet and outlet connections or manifold ports according to your specifications. Contact Information: Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 9440 phone fax industrial@parker.com Product Features: Interchangeable flow tube assemblies and valves allow configuration changes without removal from process system Rib-guided, compression sealed flow tubes for maximum float stability Ceramic scales fired on flow tubes against a contrasting background provide high visibility and durability Standard or high-resolution metering valves available on inlet or outlet Ten-to-one rangeability

2 Forged Body Flowmeters The Porter models F65 and F50 forged body flowmeters feature a compact, one-piece, black anodized forged aluminum body with wraparound windo for full 80 visibility of the flow tubes. These units are available with aluminum, brass or 36 stainless steel wetted parts. Model F65 Model F50 Side Plate Flowmeters The Porter models 65 and 50 side plate constructed flowmeters combine a traditional body style with innovative design features. They are available with aluminum, brass or 36 stainless steel wetted parts. Multi-tube (2 to 6 tube) versions are available with optional valves and manifold inlet/outlet ports. Model 65 Model 50

3 Specifications Capacities- Length: Models F65 and 65-65mm; Models F50 and 50-50mm. Type: Fused on metering tube with contrasting yellow background Graduations: Standard- Models F65 and 65: 0-65mm w/ calibration data; Models F50 and 50: 0-50mm w/ calibration data. Optional: Direct reading scales Ratings- Pressure/Temperature: Neoprene packing/ Buna N O-rings- 200 psig at temperatures up to 60 F Viton packing/viton O-rings-200 psig at temperatures up to 200 F Performance- Accuracy: Models F65 and 65: ± 0% full scale; Models F50 and 50: ± 5% full scale. Accuracy specified for 00%- 0% of scale reading ( 0 to rangeability). Repeatability: Models F65 and 65: ± 0.5% of full scale reading; Models F50 and 50: ±0.25% of full scale reading. Connections- /8 female NPT threaded adaptors with locknuts for front panel mounting. Optional: /8 compression fitting; /4 compression fitting; /4 NPT female; /4 I.D.Hose. To order, Specify: Model Number Tube Number Float Material Connections (Type & Size) Fluid Specifications (Specific gravity & viscosity) Flow Rate Operating Pressure Operating Temperature Material of Construction for a) End fitting b) Side plates or meter body c) Elastomers Materials of Construction Metering Tube- Borosilicate glass Floats- glass, stainless steel. Optional: Sapphire, carboloy and tantalum Structual Members- Metering body: (F65 and F50) black anodized aluminum. Optional: stainless steel. Wetted Parts: Aluminum, brass or 36 stainless steel End Fittings: Black anodized aluminum or chrome plated brass or 36 stainless steel Shields- Clear polycarbonate Tube packing and O-Rings- Neoprene packing and Buna N O-Rings with aluminum or brass construction. Viton packing and Viton O- rings with stainless steel construction. Optional Materials: Teflon Ordering Information Model Numbers and Description F65 A Example: V 2 Basic Model F65-65mm Forged Body F50-50mm Forged Body 65-65mm Side Plate Body 50-50mm Side Plate Body Body Material A- Aluminum B- Brass S- Stainless Steel Valve O- No Valve V- Standard Cartridge Control Valve HR- High Resolution Control Valve Valve Size 0 thru 6 High Resolution Control Vale thru 3 Standard Cartridge Valve -TG Torque Guard Taper 2-TG Torque Gurad Taper 2

4 WARNING USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. Offer of Sale The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the detailed Offer of Sale elsewhere in this document or available at 20 Parker Hannifin Corporation WS-002, Rev 0 November 20

5 P430 Series Glass Tube Flow Meters Parker P Series glass tube flowmeters deliver unsurpassed performance and value in a wide variety of gas and liquid applications. P430 Series flow meters feature borosilicate glass tubes with stainless steel frames and horizontal connections and are available with 65mm and 50mm scale sizes. Available Fiber-Optic or Inductive Ring Sensor Alarms, as well as integrated metering valves provide the needed versatility for many industrial process and sample handling applications. Contact Information: Product Features and Options: Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 9440 phone fax Industrial@parker.com Borosilicate glass metering tube. Max temperature: 250 F (2 C) for gases 200 F (93 C) for liquids Max Pressure: 200 PSIG (see specifications) Optional inductive ring and fiber optic alarm sensors available. Certified calibrations conforming to ISA RP 6.6 available. Direct reading detachable scales available in any volumetric unit.

6 Specifications Materials Metering Tube Internal Components Inlet/Outlet Fittings Fitting Material Elastomers Options Borosilicate Glass 36L Stainless Steel, Black Glass, Sapphire, Carboloy, Tantalum /8" and /4" FNPT, Horizontal Control Valve Optional 36L Stainless Steel Viton Optional: Buna, EPR, and Kalrez Fiber-Optic or Inductive Ring Alarm Sensor (see details) Certified Conform to ISA RP 6.6 Calibrations Can be produced in any volumetric Scales unit Viton and Kalrez are registered trademarks of DuPont Performance Elastomers L.L.C. Performance Capacities Scale Accuracy Turndown Water Air Repeatability % Maximum Temperature Maximum Pressures Ambient Temperature.72 to,800 cc/mn 66 to 70,000 cc/mn 65mm, 50mm Direct reading, detachable 65mm ±6% of Full Scale Flow 50mm ±4% of Full Scale Flow 0: to 2.5:, unless otherwise indicated Gases 250 F (2 C) Liquids 200 F (93 C) 36L SS Fittings 200 psig PVC Fittings 30 psig PVDF Fittings 50 psig 33 F to 25 F ( C to 52 C) Alarm Options: Inductive Ring Sensor Inductive ring sensors are designed to be used with a remote intrinsic safety barrier/switch isolator. These sensors are able to detect the metal float by producing an electromagnetic field within the ring. Ring sensors are available in either proximity or latching format for the P430 Series. Sensor Specifications Power Supply 5-25 VDC (from Switch Isolator) Maximum Current Target Present: ma Target Absent: 5 ma Temperature Limits -4 F to +58 F (-26 C to +70 C) Output NAMUR Repeatability 0.0mm Switching Frequency 2 khz (.25"),.5 khz (.25") UL Listed: General Purpose Sensor Approvals FM Approved: Intrinsically Safe* CSA Certified: Intrinsically Safe* Cenelec: Intrinsically Safe* *Additional cost, call for pricing Float/Sensor Campatibility Type Tube Sizes Float Material Proximity.25".25" SS, CB Latching.25".25" SS, CB Fiber Optic Sensor The fiber optic sensor is housed in a junction box attached to the side of a P430 Series flowmeter. The sensor uses a pair of fiber optic cables, an emitter and receiver to transmit the light across the metering tube and back to the sensor. If the light beam is blocked by the float, the sensor output will change. The sensor provides a transistor output that switches the common or negative voltage (NPN) or positive voltage (PNP) to the load. The fiber optic sensor is compatible with all P430 Series float types. Sensor Specifications Supply Voltage Current Consumption Temperature Limits Offstate Leakage Current Output Saturation Voltage 0-30 VDC 25 ma -4 F to +22 F (-26C to +00 C) microamp at 30 VDC V at 0 ma DC <.5 V at 50 ma DC Note: Sapphire floats are not compatable with Fiber Optic Sensor

7 Flow Ranges Tube Number A A2 A3 A4 A5 A6 Float Material 65mm Scale Flow Ranges Air (STP) CC/ MIN SCFH SLPH Water (70 F) CC/ MIN GPH LPH Glass Sapphire Stainless Steel Carboloy Tantalum Glass Sapphire Stainless Steel Carboloy Tantalum Glass Sapphire Stainless Steel Carboloy Tantalum Glass Sapphire Stainless Steel Carboloy Tantalum Glass Sapphire Stainless Steel 3, Carboloy 9, Tantalum 20, Glass 9, Sapphire 25, Stainless Steel 42, Carboloy 60, Tantalum 70, Tube Number B B2 B3 B4 B5 B6 B7 B8 Float Material 50mm Scale Flow Ranges Air (STP) CC/MIN SCFH SLPH Water (70 F) CC/ MIN GPH LPH Carboloy Tantalum Glass Sapphire Stainless Steel Carboloy Tantalum Glass Sapphire Stainless Steel Carboloy, Tantalum, Glass Sapphire, Stainless Steel, Carboloy 2, Tantalum 2, Glass 2, Sapphire 2, Stainless Steel 4, Carboloy 6, Tantalum 6, Glass 3, Sapphire 5, Stainless Steel 7, Carboloy 0, Tantalum, Glass 9, Sapphire, Stainless Steel 7, , Carboloy 24, , Tantalum 25, , Glass 20, , Sapphire 26, , Stainless Steel 38, , Carboloy 54, , Tantalum 60, ,

8 Ordering Information Use the following guide to determine the specific product number you require. The following example describes a P430 series flow meter, tube number A, with a glass float, /4" FNPT fitting of 36L stainless steel, a Buna O-ring, with a scale in millimeters and 36L stainless steel inlet valve. It does not have an optional alarm. Example: P430A230 P430 A 2 3 Meter Series P430 Tube Number See Flow Ranges Table Float Material Glass 2 Sapphire 3 36 Stainless Steel 4 Carboloy 5 Tantalum Dimensions Fitting Material 36L Stainless Steel /8" FNPT 2 36L Stainless Steel /4" FNPT 3 PVC /4" FNPT 4 PVC /8" FNPT 5 PVDF /4" FNPT 6 PVDF /8" FNPT 7 Hastelloy C /4" FNPT 8 Hastelloy C /8" FNPT O-Ring Material Ethylene Propylene Rubber 2 Buna 3 Viton 4 Kalrez with No Valve 5 Kalrez with Valve Hastelloy is a registered trademark of Haynes International, Inc. Viton and Kalrez are registered trademarks of DuPont Performance Elastomers L.L.C. Scale Millimeter 2 GPH 70 F (2 C) 3 LPH 70 F (2 C) 4 cc/min STP 5 SCFH STP 6 SLPH STP 7 scc/min STP 8 Non-Standard Dimensions (inches) Valve Option Inlet 36L Stainless Steel 2 Outlet 36L Stainless Steel 3 No Valve 4 Inlet PVC 5 Outlet PVC 6 Inlet PVDF 7 Outlet PVDF 8 Inlet Hastelloy C 9 Outlet Hastelloy C Scale Length 65mm 50mm A* B C D E F G *The FNPT fittings have a 3/4 6 O.D. thread with mounting nuts installed. 0 Optional Alarm Switch 0 No Alarm Fiber Optic NPN (Proximity) 2 Fiber Optic PNP (Proximity) 3 Inductive Ring Sensor (Proximity) 4 Inductive Ring Sensor (Latching) WARNING USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. Offer of Sale The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the detailed Offer of Sale elsewhere in this document or available at Parker Hannifin Corporation FM-59, Rev 0 April 200

9 P20 Series Glass Tube Variable Area Flowmeter The P20 Series Flowmeters are designed for low flow rates of both liquids and gases. They cover a broad range of applications, from purging to monitoring of industrial processes. The P20 Series offers 36 Stainless Steel construction for all wetted parts. For challenging corrosive applications, the P20 offers PTFE seals as an option. Contact Information: Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield PA, 9440 Phone Fax industrial@parker.com Product Features: Ideal for general purpose use, as well as use for field test equipment Suitable for both liquids and gases 36 Stainless Steel construction for all wetted parts PTFE seals are available as an option Front panel mounting hardware Easy-to-read scale Scale tube length of 45mm Optional alarm output

10 Specification Materials Wetted Body 36 Stainless Steel Tapered Tube Heat-resistant Glass Float 36 Stainless Steel, Glass, PTFE or Ruby NBR(Nitrile Rubber) Optional: Packing FPM(Fluorinated Propylene Monomer) CR(Neoprene) PTFE( Polytetrafluoroethylene) Fitting 36 Stainless Steel Valve 36 Stainless Steel Non-wetted Cover Polycarbonate Support Aluminum Connection NPT or RC /4 With locknuts for Size and Type front panel mounting Proper material to be selected according to the specification. Performance Flowrate Scale Ranges Water Minimum Gal/h (0.3 3 L/h) Maximum Gal/h (24 20 L/h) Air 2 Minimum ft 3 /h (0.2.2 L/h) (nor) Maximum 06 ft 3 /h ( L/h) (nor) Turndown 0: Accuracy ±5% F.S. Approximate Weight. lbs. (0.5 kg) Flow Direction Bottom Rear to Top Rear Alarm Type Self-holding Reed Switch Operating Conditions 6 psig (8 barg) (72.5 psig) (5 barg) when Max. Operating Pressure PTFE packing material is used Max. Operating Temperature NBR(Nitrile Rubber) 76 F (80 C) CR(Neoprene) PTFE(Polytetrafluoroethylene) FPM(Fluorinated Propylene 248 F (20 C) Monomer) Liquid equivalent to water density.0g/cm 3, viscosity.0cp 2 Gases equivalent to 0 C atm Reed Switch Specification point(high or Low) Number Of Point 2 point alarm also avaiable as an option. Consult factory for details. Alarm Setting Range Standard 20 to 80% of full scale(h:50 to 80%, L:20 to 50%) Reed switch(self-holding type) Max. Contact capacity: AC0VA, DC0W Contact Max. Voltage: AC25V, DC00V Max. Current: 0.5A Connection Lead wire connection of 50cm. (2m is also available) Reset-Span 25% Full Scale Ambient Temperature -0 to 60 C Caution must be taken when mounting multiple alarmed meters. Close proximity may cause interference with alarm signal.

11 Dimensional Drawing Standard Valve provided at outlet, with locknuts for front panel mounting (.2 in (30 mm)) (Max.4 in (36 mm)).4 in 0.7 in (35 mm) (9 mm) 2 NPT /4 2 ø 0.8 in (20 mm) OUT (5.5 in (40 mm)) 2 M8 4.5 in (5 mm) 4.5 in (5 mm) IN Panel Cut Dimensions Connection Size Hole Diameter in mm /4 NPT or RC ø 0.8 ø 20 Panel Max t 0 PANEL CUT /8 NPT or RC ø 0.6 ø 6 Use non-magnetized material for panel with Reed Switch alarm output Flow Range Alarm Settings Air Flow Rate Table If LO, LC, HO, or HC Alarm Output Air Alarm Setting Range ft 3 /h L/h (nor) ft 3 /h L/h (nor) ** ** Water 2 Flow Rate Table If LO, LC, HO, or HC alarm output Water Alarm Setting Range Gal/h L/h Gal/h L/h Water measured with viscosity of mpa s *0:2 if range is more than 6 Gal/h (60 L/h) Air measured at 0 psig and 32 F (0 C) When PTFE is used, a flowmeter with a valve cannot be manufactured for a flow rate less than 2. ft 3 /h (60 L/h) (nor). *0:2 if range is less than 0.2 ft 3 /h (6 L/h) (nor) **0:2 if range is more than 2 ft 3 /h (600 L/h) (nor)

12 Part Number Selection Model: P2 Application Information: Flow / Direction 2 3 Bottom rear to top rear Air flow rates >8 L/hr up to 200 L/hr Water flow rates from L/hr to L/hr Bottom rear to top rear Air flow rates < 8 L/hr Bottom rear to top rear Air flow rates >200 L/hr up to 3000 L/hr Fluid Name: Operating Density or Specific Gravity: Viscosity: Valve A B C None Bottom Top Operating Or Normal: Flowrate Alarm Output None Reed Switch - Contact closes (becomes ON) when 2 value is more than set point Reed Switch - Contact opens (becomes OFF) when 3 value is more than set point Reed Switch - Contact closes (becomes ON) when 4 value is less than set point Reed Switch - Contact opens (becomes OFF) when 5 value is less than set point Scale Range: Operating or Normal: Pressure Wetted Parts A 36 Stainless Steel (Standard) Temperature Packing Material Fluorinated Propylene Monomer (FPM/FKM) 2 Nitrile (NBR) 3 Neoprene (CR) 4 Polytetrafluoroethylene (PTFE) Operating or Normal: Connection Type A B NPT thread (standard) RC thread (Typical for Non-USA Market) Alarm Settings Connection Size /8 2 /4 Alarm : Alarm 2: Mounting Options A None (Standard with locknuts for front panel mounting) Other Options Example: P2 A A A A Liquid equivalent to water density.0g/cm 3, viscosity.0cp Gases equivalent to 0 C atm WARNING USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. Offer of Sale The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the detailed Offer of Sale elsewhere in this document or available at 20 Parker Hannifin Corporation FM-90, Rev 0 July 20

13 P220 Series Glass Tube Variable Area Flowmeter The P220 Series Flowmeters are designed for low flow rates of both liquids and gases. The P220 Series covers a broad range of applications, from purging to monitoring of industrial processes. The P220 offers 36 Stainless Steel construction for all wetted parts. For challenging corrosive applications, the P220 offers PTFE seals as an option. Contact Information: Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield PA, 9440 Phone Fax industrial@parker.com Product Features: Ideal for general purpose use, as well as use for field test equipment Suitable for both liquids and gases 36 Stainless Steel construction for challenging corrosive applications Front panel mounting hardware Easy-to-read scale Scale tube length of 00mm Optional alarm output

14 Specification Materials Body Tapered Tube Float Packing Fitting Valve Cover Support Connection Size and Type Wetted 36 Stainless Steel Heat-resistant Glass 36 Stainless Steel, Glass, PTFE or Ruby NBR (Nitrile Rubber) Optional: FPM (Fluorinated Propylene Monomer) CR (Neoprene) 36 Stainless Steel 36 Stainless Steel Non-wetted Polycarbonate Aluminum NPT or RC /4 With locknuts for front panel mounting Proper material to be selected according to the specification. Performance Flowrate Scale Ranges Water Minimum Gal/h (0.3 3 L/h) Maximum Gal/h (24 20 L/h) Air 2 Minimum ft 3 /h (0.3 3 L/h) (nor) Maximum 3 27 ft 3 /h ( L/h) (nor) Turndown 0: Accuracy ±3% F.S. Approximate Weight.3 lbs. (0.6 kg) Flow Direction Bottom Rear to Top Rear Alarm Type Max. Operating Pressure Max. Operating Temperature NBR (Nitrile Rubber) CR (Neoprene) Operating Conditions Self-holding Reed Switch 6 psig (8 barg) 76 F (80 C) FPM (Fluorinated Propylene Monomer) 248 F (20 C) Liquid equivalent to water density.0g/cm 3, viscosity.0cp 2 Gases equivalent to 0 C atm Reed Switch Specification point(high or Low) Number Of Point 2 point alarm also available as an option. Consult factory for details. Alarm Setting Range Standard 20 to 80% of full scale(h:50 to 80%, L:20 to 50%) Reed switch(self-holding type) Max. Contact capacity: AC0VA, DC0W Contact Max. Voltage: AC25V, DC00V Max. Current: 0.5A Connection Lead wire connection of 50cm. (2m is also available) Reset-Span 25% Full Scale Ambient Temperature -0 to 60 C Caution must be taken when mounting multiple alarmed meters. Close proximity may cause interference with alarm signal.

15 Dimensional Drawing Standard Valve provided at outlet, with locknuts for front panel mounting (.2 in (30 mm)) (Max.4 in (36 mm)).4 in 0.7 in (35 mm) (9 mm) 2 NPT /4 2 ø 0.8 in (20 mm) OUT (8.9 in (225 mm)) 7.9 in (200 mm) 2 M8 7.9 in (200 mm) IN Panel Max t 0 PANEL CUT Panel Cut Dimensions Hole Diameter Connection Size in mm /4 NPT or RC ø 0.8 ø 20 /8 NPT or RC ø 0.6 ø 6 Use non-magnetized material for panel with Reed Switch alarm output Flow Range Alarm Settings Air Flow Rate Table Water 2 Flow Rate Table If LO, LC, HO, or HC alarm output If LO, LC, HO, or HC alarm output Air Alarm Setting Range Water Alarm Setting Range ft 3 /h L/h (nor) ft 3 /h L/h (nor) Gal/h L/h Gal/h L/h Water measured with viscosity of mpa s * * Air measured at 0 psig and 32 F (0 C) *0:2 if range is more than 85 ft 3 /h (nor) (2400 L/h) (nor)

16 Part Number Selection Model: P22 Application Information: Flow / Direction 2 Bottom rear to top rear Gas flow rates >30 L/hr up to 3600 L/hr All Liquids ranges from L/hr to 2-20 L/hr Bottom rear to top rear Gas flow rates < 30 L/hr Fluid Name: Operating Density or Specific Gravity: Viscosity: Valve A B C None Bottom Top Flowrate Alarm Output None Reed Switch - Contact closes (becomes ON) when value 2 is more than set point Reed Switch - Contact opens (becomes OFF) when 3 value is more than set point Reed Switch - Contact closes (becomes ON) when value 4 is less than set point Reed Switch - Contact opens (becomes OFF) when 5 value is less than set point Operating Or Normal: Scale Range: Pressure Wetted Parts A 36 Stainless Steel (Standard) Operating or Normal: Packing Material Fluorinated Propylene Monomer (FPM/FKM) 2 Nitrile (NBR) 3 Neoprene (CR) A NPT thread (standard) Temperature Operating or Normal: Connection Type B RC thread (Typical for Non-USA Market) Connection Size /8 2 /4 Alarm : Alarm Settings Mounting Options A None (Standard with locknuts for front panel mounting) Alarm 2: Example: 22 A A A A Other Options Liquid equivalent to water density.0g/cm 3, viscosity.0cp Gases equivalent to 0 C atm WARNING USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. Offer of Sale The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the detailed Offer of Sale elsewhere in this document or available at 20 Parker Hannifin Corporation FM-9, Rev 0 July 20

17 P230 Series Glass Tube Variable Area Flowmeter The P-230 Series Flowmeters are highly reliable and accurate flowmeters commonly used in industrial production processes. They feature SCS4 (Equivalent to 36 SS) construction for use with many types of corrosive gases and liquids, making them optimal for demanding industrial applications. They are available in a variety of operating flow ranges. Contact Information: Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield PA, 9440 Phone Fax industrial@parker.com Product Features: Standard construction utilizes SCS4 (Equivalent to 36 SS) wetted parts for use in most any application including corrosive applications Industry standard lay lengths for 65mm and 50mm scales CR (Neoprene) packing material available for ammonia gas

18 Specification Materials Body Tapered Tube Float Packing Spindle Fitting Valve Cover Mounting Board Connection Size and Type Wetted SCS4 (Equivalent to 36 SS) Heat-resistant Glass 36 Stainless Steel, Glass, PTFE or Ruby FPM (Fluorinated Propylene Monomer) Optional: CR (Neoprene) 36 Stainless Steel 36 Stainless Steel 36 Stainless Steel Non-wetted Acrylic SPCC (Cold Rolled Carbon Steel Sheets) NPT or RC /4 With locknuts for front panel mounting Proper material to be selected according to the specification. Performance Flowrate Scale Ranges Water Gal/h Minimum (0.3 3 L/h) Gal/h Maximum (24 20 L/h) Air ft 3 /h Minimum (0.2.2 L/h) (nor) ft 3 /h Maximum ( L/h) (nor) Turndown 0: ±5% F.S. for 65mm Tube Accuracy ±3% F.S. for 50mm Tube Approximate Weight.3 lbs. (0.5 kg) Flow Direction Bottom to Top Operating Conditions Max. Operating Pressure 6 psig (8 barg) Max. Operating Temperature CR (Neoprene) 76 F (80 C) FPM (Fluorinated Propylene 248 F (20 C) Monomer) Liquid equivalent to water density.0g/cm 3, viscosity.0cp 2 Gases equivalent to 0 C atm Standard Flow Capacity Ranges Air Flow Rate Table Air ft 3 /h L/h (nor) * 0.6 6* *** *** ** ** Water 2 Flow Rate Table Water Gal/h L/h * 8 90* Liquid equivalent to water density.0g/cm 3, viscosity.0 cp *0:2 if range is more than 24 Gal/h (90 L/h) ** 0:2 if range is more than 6 Gal/h (60 L/h) Air measured at 0 psig and 32 F (0 C) *0:2 if range is less than 0.2 ft 3 /h (6 L/h) (nor) **0:2 if range is more than 64 ft 3 /h (800 L/h) (nor) ***0:2 if range is more than 2 ft 3 /h (600 L/h) (nor)

19 Part Number Selection Model: P23 Flow/Direction Valve Alarm Output Wetted Parts Packing Material Connection Type Connection Size Mounting Options 65 mm Size Range Direction Air: L/hr up to L/hr Water: L/hr up to L/hr 2 50 mm Air: L/hr up to L/hr Water: L/hr up to L/hr A None B Precision Valve - Bottom C Precision Valve - Top D Standard Valve - Bottom E Standard Valve - Top None B SCS4 (Equivalent to 36 SS) Fluorinated Propylene Monomer (FPM/FKM) 3 Neoprene (CR) A NPT thread (standard) B RC thread (Typical for Non-USA Market) 2 /4 A None (Standard with locknuts for front panel mounting) Bottom Rear to Top Rear (Standard) Bottom Rear to Top Rear (Standard) Example: P23 A B A 2 A Liquid equivalent to water density.0g/cm 3, viscosity.0cp Gases equivalent to 0 C atm Required Information: Fluid Name: Operating Density or Specific Gravity: Viscosity: Flowrate Operating Or Normal: Scale Range: Operating or Normal: Pressure Operating or Normal: Temperature Alarm : Alarm 2: Alarm Settings

20 Dimensional Drawing Standard NPT /4 connection, needle valve provided at inlet, locknuts for front panel mounting 65 MM 50 MM OUT OUT 5.6 in (43 mm) 4.5 in (5 mm) 4.5 in (5 mm) 9.9 in (252 mm) 8.8 in (224 mm) 8.8 in (224 mm) 2 Ø d 2 Ø d IN IN.2 in (3 mm) (Max.2 in (3 mm)). in (28 mm) (L) 2 NPT /4 2 M20 Panel Cut PANEL CUT.2 in (3 mm) (Max.2 in (3 mm)). in (28 mm) (L) 2 NPT /4 Panel Cut PANEL CUT 2 M20 Hole Diameter (d) Rear Length (L) Connection Size in mm in mm NPT / WARNING USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. Offer of Sale The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the detailed Offer of Sale elsewhere in this document or available at 20 Parker Hannifin Corporation FM-92, Rev 0 July 20

21 P240 Series Glass Tube Variable Area Flowmeter The P240 Series Flowmeters are designed to extend the flow capacity of a traditional purgemeter given an outstanding performance for a wide range of liquids and gases. The SCS4 (Equivalent to 36 SS) construction allows for usage with many types of corrosive gases and liquids making it optimal for demanding industrial applications. Contact Information: Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield PA, 9440 Phone Fax industrial@parker.com Product Features: Ideal for general purpose use, as well as use for industrial process applications SCS4 (Equivalent to 36 SS) construction for challenging corrosive applications Front panel mounting hardware Easy-to-read scale Suitable for both liquids and gases Optional alarm output

22 Specification Materials Body Tapered Tube Float Packing Spindle Valve Mounting Board Cover Connection Type and Size Wetted SCS4 (Equivalent to 36 SS) Heat-resistant Glass 304 Stainless Steel and PTFE (36 Stainless Steel available) NBR(Nitrile Rubber) Optional: FPM(Fluorinated Propylene Monomer) CR(Neoprene) EPDM(Ethylene Propylene Diene Monomer) 304 Stainless Steel 304 Stainless Steel Non-wetted SPCC(Cold Rolled Carbon Steel Sheets and Strip) Optional: (304 Stainless Steel available) Consult Factory for details Acrylic NPT or RC 3/8 With locknuts for front panel mounting Performance Water Minimum Maximum Liquid equivalent to water density.0g/cm 3, viscosity.0cp 2 Gases equivalent to 0 C atm Flowrate Scale Ranges.6 6 Gal/h (6 60 L/h) Gal/h ( L/h) Air 2 Minimum ft 3 /h ( L/h) (nor) Maximum ft 3 /h ( L/h) (nor) Turndown 0: Accuracy ±5% F.S. Approximate Weight Alarm Type Max. Operating Pressure Operating Conditions Max. Operating Temperature NBR(Nitrile Rubber) CR(Neoprene) EPDM(Ethylene Propylene Diene Monomer) FPM(Fluorinated Propylene Monomer) 4.4 lbs. (2 kg) Self-holding Reed Switch 6 psig (8 barg) 76 F (80 C) 248 F (20 C) Proper material to be selected according to the specification. Reed Switch Specification point(high or Low) Number Of Point 2 point alarm also available as an option. Consult factory for details. Alarm Setting Range Standard 20 to 80% of full scale(h:50 to 80%, L:20 to 50%) Reed switch(self-holding type) Max. Contact capacity: AC0VA, DC0W Contact Max. Voltage: AC25V, DC00V Max. Current: 0.5A Connection Lead wire connection of 50cm. (2m is also available) Reset-Span 25% Full Scale Ambient Temperature -0 to 60 C Caution must be taken when mounting multiple alarmed meters. Close proximity may cause interference with alarm signal.

23 W Dimensional Drawing Standard Valve provided at outlet, panel front thread (M3) mounting type (9.2 in (234 mm)) (2. in (54 mm)) (Max.7 in.8 in (42 mm)) (45 mm) 2 NPT 3/8 7.9 in (200 mm) OUT IN. in (2929 mm) 2 ø. in (28 2-φ28 mm) φ4 ø 0.2 in (4 mm) in (55 mm) 7.9 in (200 mm) (0.9 in (22.5 mm)) (0.9 in (22.5 mm)) Panel Front Installation Valve provided at outlet, Standard with locknuts for front panel mounting (9.2 in (234 mm)) (2. in (54 mm)) (Max.7 in.8 in (42 mm)) (45 mm) L 7.9 in (200 mm) Panel Max t 0 2 M26 2 ø d OUT IN 7.9 in (200 mm) 0.5 in (3.5 mm) 0.5 in (3.5 mm) Bezel Valve provided at outlet, bezel installation, mounting option code C 2 ø 0.2 in (5 mm) Bezel. in (Board thickness 0. in (3 mm)) (29 mm) 4 ø 0.2 in (6 mm) 0.9 in (22.5 mm) 6. in (55 mm) 5 in (28 mm) ø. in (27 mm) Max.7 in (43 mm) 9.4 in (240 mm) 4.9 in (24 mm) id th ( 4 0 ) Width (.6 in (40mm)) (9.2 in (234 mm)) Panel (Board thickness) 2 NPT 3/8 7.9 in (200 mm) OUT IN PANEL CUT Connection Size Rear Length (L) Hole Dia. ø in mm in mm in mm NPT 3/ NPT 3/8 PANEL CUT 2.4 in (2. in (Max.7 in.8 in Flow Range Alarm Settings Water Flow Rate Table If LO, LC, HO, or HC alarm output Water Alarm Setting Range Gal/h L/h Gal/h L/h * 2 20* ** ** Liquid equivalent to water density.0g/cm 3, viscosity.0cp *Float material should be PVC. **Available for viscosity cp only Air 2 Flow Rate Table If LO, LC, HO, or HC Alarm Output Air Alarm Setting Range ft 3 /h L/h (nor) ft 3 /h L/h (nor) 06* * Air measured at 0 psig and 32 F (0 C *Float material should be PVC.

24 Part Number Selection Model: P24 Required Information: Bottom rear to top rear (standard) Air flow rates from L/hr up to L/hr Water flow rates from 6-60 L/hr up to L/hr Fluid Name: Operating Density or Specific Gravity: Flow / Direction 2 Bottom to top Air flow rates from L/hr up to L/hr Water flow rates from 6-60 L/hr up to L/hr Viscosity: A None Flowrate Valve B C Bottom Top Alarm Output None Reed Switch - Contact closes (becomes ON) when value 2 is more than set point Reed Switch - Contact opens (becomes OFF) when value 3 is more than set point Reed Switch - Contact closes (becomes ON) when value 4 is less than set point Reed Switch - Contact opens (becomes OFF) when value 5 is less than set point Operating Or Normal: Scale Range: Pressure Operating or Normal: Wetted Parts Packing Material B SCS4 (Equivalent to 36 SS) Fluorinated Propylene Monomer (FPM/FKM) 2 Nitrile (NBR) 3 Neoprene (CR) 5 Ethylene Propylene Diene Monomer (EPDM) Temperature Operating or Normal: A NPT thread (Standard) Connection Type Connection Size B RC thread (Typical for Non-USA Market) 3 3/8 (Standard) 4 /2 (Not available for RC thread connection type) 5 3/4 6 A None (Standard with locknuts for front panel mounting) Alarm : Alarm 2: Alarm Settings Other Options Mounting Options B C Panel Rear Installation Bezel Installation Example: P24 A B A 3 A Liquid equivalent to water density.0g/cm 3, viscosity.0 cp Gases equivalent to 0 C atm WARNING USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. Offer of Sale The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the detailed Offer of Sale elsewhere in this document or available at 20 Parker Hannifin Corporation FM-93, Rev 0 July 20

25 P250 Series Glass Tube Variable Area Flowmeter The P250 Series Flowmeters are designed to extend the flow capacity of a traditional purgemeter given an outstanding performance for a wide range of water applications. All wetted materials are constructed of SCS4 (Equivalent to 36 SS). Laser engraved graduations and a magnifying lens provides users with a quick, precise, easy and accurate reading of the flow measurement scale. Contact Information: Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield PA, 9440 Phone Fax industrial@parker.com Product Features: Ideal for general purpose use, as well as use for industrial process applications SCS4 (Equivalent to 36 SS) construction for challenging corrosive applications Front panel mounting hardware Easy-to-read scale Designed for accurate flow measurement of water applications

26 Specification Materials Body Tapered Tube Float Packing Spindle Valve Support Connection Size and Type Wetted SCS4 (Equivalent to 36 SS) Heat-resistant Glass 36 Stainless Steel NBR (Nitrile Rubber) Optional: FPM (Fluorinated Propylene Monomer) 36 Stainless Steel 36 Stainless Steel Non-wetted 304 Stainless Steel NPT or RC 3/8 With locknuts for front panel mounting Performance Scale Range (water) Water.6-6 Gal/h Minimum (6-60 L/h) Gal/h Maximum ( L/h) Turndown 0: Accuracy ±5% F.S. Approximate Weight 4 lbs. (2 kg) Operating Conditions Max. Operating Pressure 6 psig (8 barg) Max. Operating Temperature NBR (Nitrile Rubber) 76 F (80 C) FPM (Fluorinated Propylene 248 F (20 C)* Monomer) Liquid equivalent to water density.0g/cm 3, viscosity.0cp *Maximum 80 C in case of water Proper material to be selected according to the specification. Dimensional Drawing Standard Type Valve Provided at Outlet, Panel Front Thread (2. in (54 mm)) (Max.7 in (42 mm)).8 in (45 mm) 2 NPT 3/8 PANEL CUT 2 ø 0.3 in 2- (828 mm) (0.9 in (22.5 mm)) OUT (22.5) ø (9.2 in (234 mm)) 7.9 in (200 mm) IN. in (29 mm) (22.5) 6. in (55mm) in (200 mm) Panel Cut Dimensions Hole Diameter Rear Diameter Connection in mm in mm (0.9 in (22.5 mm)) NPT 3/8 ø. ø 28 26

27 Part Number Selection Model: P25 Flow / Direction Valve Alarm Output Wetted Parts Packing Material Connection Type Connection Size Mounting Options A B C Bottom rear to top rear (standard) Water flow rates from 6-60 L/hr up to L/hr None Bottom Top None B SCS4 (Equivalent to 36 SS) Fluorinated Propylene Monomer (FPM/FKM) 2 Nitrile (NBR) A NPT thread (standard) B RC thread (Typical for Non-USA Market) 3 3/8 (Standard) 4 /2 A None (Standard with locknuts for front panel mounting) Example: P25 A B A 3 A Water density.0g/cm 3, viscosity.0cp Required Information: Fluid Name: Operating Density or Specific Gravity: Viscosity: Flowrate Operating Or Normal: Scale Range: Operating or Normal: Pressure Operating or Normal: Temperature Alarm : Alarm 2: Alarm Settings

28 WARNING USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. Offer of Sale The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the detailed Offer of Sale elsewhere in this document or available at 20 Parker Hannifin Corporation FM-94, Rev 0 July 20

29 P260 Series Glass Tube Variable Area Flowmeter The P260 Series Flowmeters are optimized for measuring low flow rates of water, air, and nitrogen, making it ideal for OEM applications. Laser engraved graduations and a magnifying lens provides users with a quick, precise, easy and accurate reading of the flow measurement scale. Contact Information: Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield PA, 9440 Phone Fax industrial@parker.com Product Features: Valve can be placed in bottom or top position Laser engraved graduations and magnifying lens make reading flow measurement scale quick and easy Ideal for OEM applications Standard ranges for N2, Air and Water

30 Specification Materials Body Tapered Tube Float Packing Support Front Panel Scale Panel Connection Size and Type Wetted SCS4 (Equivalent to 36 SS) Heat-resistant Glass 304 Stainless Steel, Glass, PTFE or Ruby NBR(Nitrile Rubber) Optional: FPM (Fluorinated Propylene Monomer) Non-wetted 6063-T5 Aluminum Acrylonitrile Butadiene Styrene (ABS) Polycarbonate NPT or RC /4 With locknuts for front panel mounting Proper material to be selected according to the specification. Performace Flowrate Scale Ranges Water Minimum Gal/h (0.3 3 L/h) Maximum Gal/h (24 20 L/h) Air 2 Minimum ft 3 /h (6-60 L/h) (nor) Maximum 06 ft 3 /h ( L/h) (nor) Turndown 0: Accuracy ±5% F.S. Approximate Weight. lbs. (0.5 kg) Flow Direction Bottom Rear to Top Rear Operating Conditions Max. Operating Pressure 6 psig (8 barg) Max. Operating Temperature NBR (Nitrile Rubber) 76 F (80 C) FPM (Fluorinated Propylene Monomer) 248 F (20 C) Liquid equivalent to water density.0g/cm 3, viscosity.0cp 2 Gases equivalent to 0 C atm Dimensional Drawing Standard Type Valve Provided at Outlet (.3 in (30 mm)) Max in (26 mm) (.2 in 0.7 in (3 mm)) (7 mm) PANEL CUT 2 ø 0.8 in (20 mm) d 2 NPT /4 OUT 2 D2 M8 (5.5 in (40 mm)) 4.5 in (5 mm) 4.5 in (5 5 mm) IN

31 Standard Flow Capacity Ranges Flow Rate Table Water Air 2 Gal/h L/h ft 3 /h L/h (nor) Liquid equivalent to water density.0g/cm 3, viscosity.0cp 2 Gases equivalent to 0 C atm Part Number Selection Model: P26 Required Information: Flow / Direction Valve Alarm Output Wetted Parts Packing Material Connection Type Connection Size Mounting Options A B C Example: P26 A B A 2 A Liquid equivalent to water density.0g/cm 3, viscosity.0cp Gases equivalent to 0 C atm Bottom rear to top rear (standard) Air flow rates from 6-60 L/hr up to L/hr Water flow rates from L/hr up to L/hr None Bottom Top None B SCS4 (Equivalent to 36 SS) Fluorinated Propylene Monomer (FPM/FKM) 2 Nitrile (NBR) A NPT thread (standard) B RC thread (Typical for Non-USA Market) 2 /4 (Standard) None (Standard with locknuts for front panel A mounting) Fluid Name: Operating Density or Specific Gravity: Viscosity: Flowrate Operating Or Normal: Scale Range: Pressure Operating or Normal: Temperature Operating or Normal: Alarm Settings Alarm : Alarm 2: Other Options

Glass Tube Variable Area Flowmeter

Glass Tube Variable Area Flowmeter GT 1000 Series Models 1020, 1024, 1026, 1027 Design Specifications DS-GT 1000 April, 1997 (Supersedes issue dated December, 1996) Glass Tube Variable Area Flowmeter Wide choice of application-specific

More information

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Brooks MT3600 Series Metal Tube Variable Area Flowmeters Data Sheet Flanged, NPT or socket-welded connections 10% full scale accuracy Disassembly for cleaning without removal from the process line Standard direct reading, detachable scales Permanent magnetic

More information

P SERIES PURGEMETERS. Full Coverage for Semi-Conductor Processes for Built-IN Use for Equipment for General Industrial Processes

P SERIES PURGEMETERS. Full Coverage for Semi-Conductor Processes for Built-IN Use for Equipment for General Industrial Processes P SERIES PURGEMETERS Full Coverage for Semi-Conductor Processes for Built-IN Use for Equipment for General Industrial Processes P SERIES PURGEMETERS PRODUCTS INFORMATION P-100 P.3 P-200 P.5 P-300 P.7 P-400

More information

For liquid measurement, Water (Sp. Gr. 1.0, Viscosity 1.0cP) For gas measurement, Air at 0 o C, 1atm Q=Q0 X

For liquid measurement, Water (Sp. Gr. 1.0, Viscosity 1.0cP) For gas measurement, Air at 0 o C, 1atm Q=Q0 X FLOW RATE INDICATION In this catalogue, possible measuring range for each model is shown in the following conditions: For liquid measurement, Water (Sp. Gr. 1.0, Viscosity 1.0cP) For gas measurement, Air

More information

Ar-Mite TM Low Flow Armored Flowmeter

Ar-Mite TM Low Flow Armored Flowmeter Data Sheet Brooks Ar-Mite TM MT 3750C Ar-Mite TM Low Flow Armored Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm

More information

MT3750C Series. Metal Tube Variable Area Flowmeters. Ships in 5 days. Overview. Product Description. Features. Variable Area

MT3750C Series. Metal Tube Variable Area Flowmeters. Ships in 5 days. Overview. Product Description. Features. Variable Area DS-VA-MT3750C-eng September, 2017 Data Sheet MT3750C Series MT3750C Series Ships in 5 days Overview Variable Area Metal Tube Variable Area Flowmeters Brooks MT3750 meter operation is based on the variable

More information

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS) MAXIFLO TM Overview MaxiFlo TM KM Series Metal Tube Rotameters are rugged, versatile and accurate variable area (VA) flow meter offering 2.0% full scale accuracy. It s based on simple and easy-to-understand

More information

MT3750C Series. Metal Tube Variable Area Flowmeters. Overview. Product Description. Features. Variable Area

MT3750C Series. Metal Tube Variable Area Flowmeters. Overview. Product Description. Features. Variable Area DS-VA-MT3750C-eng March, 2015 Data Sheet MT3750C Series MT3750C Series Variable Area Metal Tube Variable Area Flowmeters Overview Brooks MT3750 meter operation is based on the variable area principle.

More information

The Safest Connections...

The Safest Connections... The Fluid Manager The Safest Connections... The Lutz Accessory Range for Electrical & Pneumatic Drum, Tote and Container Pumps A c c e s s o r y R a n g e Accessory Range Safety is our Concern At a glance

More information

ZoomLock TM Flame-Free Refrigerant Fittings

ZoomLock TM Flame-Free Refrigerant Fittings ZoomLock TM Flame-Free Refrigerant Fittings Form P-528, Engineering Specification, February 2018 FLAME-FREE REFRIGERANT FITTINGS Page 2 / ZoomLock Engineering Specification PART 1: GENERAL 1.0 SUMMARY

More information

Brooks MT3750 Low Flow Armored Flowmeter

Brooks MT3750 Low Flow Armored Flowmeter Brooks MT3750 Low Flow Armored Flowmeter ArMite TM Model MT3750 Metal Tube Flowmeter ArMite TM Model MT3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm Benefits: Wetted Parts made from Stainless

More information

Models Series Series

Models Series Series Models 31800-Series 31801-Series INDUSTRIAL DIAPHRAGM PUMPS 4 GPM/15 LPM FEATURES Self-Priming Easy Installation Can run dry without damage Low Amp Draw Flow to 4 GPM/15 LPM Compact Size Thermal Overload

More information

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology Data Sheet Brooks Model MT 3810 Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology GENERAL FEATURES Broad range of flow capacities 5% Full scale accuracy

More information

Rosemount 3051CFP Integral Orifice Flowmeter

Rosemount 3051CFP Integral Orifice Flowmeter December 2013 Rosemount 3051 Rosemount 3051CFP Integral Orifice Flowmeter See Specifications on page 47 and options for more details on each configuration. Rosemount 3051CFP Integral Orifice Flowmeters

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview The flow measuring principle is based on the Coriolis Effect. The FCS sensor s measuring tubes are energized by an electromechanical driver circuit which oscillates them at their resonance frequency.

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical

More information

Variable Area Flowmeters Ratosight TM Flow Rate Indicators with Optional Ratolarm - 10A2235

Variable Area Flowmeters Ratosight TM Flow Rate Indicators with Optional Ratolarm - 10A2235 Data Sheet (US) Variable Area Flowmeters Ratosight TM Flow Rate Indicators with Optional Ratolarm - 10A2235 Easily Cleaned - Disassembly is simplified by O-ring construction MODEL 10A2235A-OA Virtually

More information

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Electronics based on Smart Meter Manager TM Technology

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Electronics based on Smart Meter Manager TM Technology Data Sheet Models MT 3809 & 3819 Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Electronics based on Smart Meter Manager TM Technology Broad range of flow capacities 2%

More information

MagMaster MFE flowmeters feature an innovative multifrequency

MagMaster MFE flowmeters feature an innovative multifrequency INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor MagMaster MFE Series Flowmeters Electromagnetic Sensors Features Include Unrivalled flow performance- ±0.2% accuracy. Pulsed DC Technology Incorporates

More information

Models Series Series

Models Series Series Models 3180-Series 3181-Series INDUSTRIAL DIAPHRAGM PUMPS Commercial Duty, 3 GPM/1 LPM FEATURES Sealless Easy Installation Run Dry Ability Flow to 3 GPM/1 LPM Self-Priming Low Amp Draw Thermal Overload

More information

Using the Model 1500 Portable Chilled Mirror Hygrometer

Using the Model 1500 Portable Chilled Mirror Hygrometer APPLICATION NOTE 2016_0120 MODEL 1500 Rev C Using the Model 1500 Portable Chilled Mirror Hygrometer The Model 1500 is a portable, multi-function, optical chilled mirror hygrometer designed to accurately

More information

¼ Dosing and Transfer Pump. Same Great Name. Revolutionary New Design.

¼ Dosing and Transfer Pump. Same Great Name. Revolutionary New Design. ¼ Dosing and Transfer Pump Same Great Name. Revolutionary New Design. The Industry s Best Dosing Pump Just Got A ¼ Better. When we set out to redesign our ¼ double diaphragm pump, we insisted on the industry

More information

Carbon Dioxide Sample-Draw Detector Operator s Manual

Carbon Dioxide Sample-Draw Detector Operator s Manual 35-3001-05-03 Carbon Dioxide Sample-Draw Detector Operator s Manual Part Number: 71-0413 Revision: 0 Released: 8/4/17 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

ISO-9001:2008 DESICCATORS CATALOG. Phone: Fax: Web:

ISO-9001:2008 DESICCATORS CATALOG. Phone: Fax: Web: ISO-900:008 DESICCATORS CATALOG Phone: 8 496 0900 Fax: 8 496 0400 Email: sales@expotechusa.com Web: www.expotechusa.com TABLE OF CONTENTS Vacuum... Cabinets... Desiccants... 8 Vacuum SCIENCEWARE Vacuum,

More information

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller Order from: C A Briggs Company 622 Mary Street; Suite 101; Warminster, PA 18974 Phone: 267-673-8117-800-352-6265; Fax: 267-673-8118 Sales@cabriggs.com - www.cabriggs.com Page 1-2 Sepra-Lite Integral Optic

More information

FS-100 Series OUTLINE MAIN APPLICATIONS FEATURES LEVEL SWITCH

FS-100 Series OUTLINE MAIN APPLICATIONS FEATURES LEVEL SWITCH PERFECT ISOLATION BY MAGNET COUPLING COVERING HIGH TEMP., HIGH PRESS., AND VACUUM APPLICATIONS PRESSURE TIGHT FLAMEPROOF FOR HYDROGEN ATMOSPHERE READY SPRING BALANCED DISPLACER TYPE FS- Series LEVEL SWITCH

More information

Rosemount 3051CFC Compact Flowmeter

Rosemount 3051CFC Compact Flowmeter CFC Compact Flowmeter CFC Compact Flowmeters provide a quick, reliable installation between existing raised face flanges. Depending on your application needs, you can reduce energy loss with the Compact

More information

Thermo Scientific Air Cadet

Thermo Scientific Air Cadet Thermo Scientific Air Cadet Vacuum/Pressure Pumps Air Cadet Vacuum Pumps Features A B C Compact size makes pumps ideal for portable applications. All-plastic, convoluted diaphragm design handles many vacuum/pressure

More information

General Specifications

General Specifications General Specifications Model DM8 Vibration Type Liquid Density Meter Overview In 1967, YOKOGAWA developed the Model VD6 Vibration Type Liquid Density Meter in response to user requests for an online density

More information

Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications

Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications 70-82-03-06 July 2004 Overview Honeywell s 7777 Series of electrode mountings enables an

More information

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable.

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable. http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Reducing Valve Direct Mount Type with Pressure Gauge 232 Direct Mount Type (Compact size) Pressure Gauge is selectable. Display

More information

SEC Signature Process Gas Analyzer

SEC Signature Process Gas Analyzer SEC Signature Process Gas Analyzer Instruction and Operation Manual Sensor Electronics Corporation 5500 Lincoln Drive Minneapolis, Minnesota 55436 USA (952) 938-9486 Fax (952) 938-9617 email sensor@minn.net

More information

PUV, PIR and PFO Series BROCHURE

PUV, PIR and PFO Series BROCHURE PUV, PIR and PFO Series BROCHURE JUNHO 2013 ABB Multiwave TM process photometers PUV3402, PIR3502 and PFO3372 Measure vapor and liquid samples in IR, NIR, UV and VIS regions Process photometers PUV3402,

More information

Vacuum related component model series variation

Vacuum related component model series variation Vacuum related component model series variation Vacuum related components Vacuum pad Vacuum ejector/vacuum unit VSLF series VSFB Series VSFU Series Series

More information

Ultrasonic Point Level Switches

Ultrasonic Point Level Switches see more at SORInc.com Request Quote Ultrasonic Point Level Switches Ultrasonic point level switches are a cost-effective solution for your applications. Installation requires mounting the sensor (threaded

More information

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION SEC SIGNATURE ETO MONITOR SIGETO1420597 PRODUCT INTRODUCED TO ETHYLENE OXIDE STERILIZATION INDUSTRY IN 2001. OVER 850 UNITS IN FIELD WORLDWIDE

More information

PREMIUM MAGNETIC-DRIVE SEALLESS CENTRIFUGAL PUMPS DB & SP SERIES

PREMIUM MAGNETIC-DRIVE SEALLESS CENTRIFUGAL PUMPS DB & SP SERIES PREMIUM MAGNETIC-DRIVE SEALLESS CENTRIFUGAL PUMPS PUMPING SOLUTIONS AROUND THE WORLD QLVKWKRPSVRQ FRP DB SERIES SP SERIES MAGNETIC DRIVE, SEALLESS, CENTRIFUGAL PUMPS DB SERIES FLOODED SUCTION Backed by

More information

Speciality Chemicals AGAS MPG PLUS SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES

Speciality Chemicals AGAS MPG PLUS SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS

More information

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size).

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size). http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Redcing Valve with Built-in Filter Filter Regulator 238 Filter for Drain and Dust (Filtering Accuracy: 5µm) Plastic made Bowl

More information

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems 41 Accurate Condition Monitoring made Quick, Simple and Cost Effective The (IOS) is an innovative solution to the

More information

Model DE-3 Air Release Head

Model DE-3 Air Release Head SPECIFICATIONS Model Air Release Head Bulletin SS03037 Issue/Rev. 0.3 (8/17) Smith Meter Air Eliminator The Smith Meter Model Air Release Heads are an electric float switch devices for installation on

More information

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids Instrumentation for fluids Target Flowmeter Series DP-65 DP-500 Flow measurement of Gases and Liquids Metallic construction. Operates horizontally or vertically DN-80 to DN-500 Flow rate: - Water: 1.5

More information

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids UK / Europe Office Tel: +44 (0)8700 434040 Fax: +44 (0)8700 434045 info@omniinstruments.co.uk www.omniinstruments.co.uk Australia / Asia Pacific Office Tel +61 (0)282 442 363 Fax +61 (0)294 751 278 info@omniinstruments.com.au

More information

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm) http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made

More information

ProMinent ProMus Hydraulic Diaphragm Metering Pumps

ProMinent ProMus Hydraulic Diaphragm Metering Pumps ProMinent ProMus ProMinent ProMus Description: The ProMus is a motor driven metering pump with a hydraulically actuated diaphragm. The drive case and the hydraulic unit are filled with a liquid that functions

More information

KOBOLD PSR/PS FLOW SWITCH

KOBOLD PSR/PS FLOW SWITCH KOBOLD PSR/PS FLOW SWITCH User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com Manual-PSR-PS_8-10 PSR/PS Table

More information

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description

More information

Direct reading flowmeters type RM

Direct reading flowmeters type RM FLOWMETERS 7 Direct reading flowmeters type RM The direct reading flowmeters type RM are flow measuring devices suitable for small flows of liquid and gaseous fluids. The measure cone is got directly from

More information

Internal Use Only INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR

Internal Use Only INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR ELECTRICAL OR HIGH-DENSITY MAGNETIC ANTI-SCALE OR WATER CONDITIONING APPLIANCE IGC 91-2009 1. PURPOSE 1.1 The purpose

More information

The A-series Eletta Flow Monitor with local indication and analog output

The A-series Eletta Flow Monitor with local indication and analog output The A-series Eletta Flow Monitor with local indication and analog output GL series FA series GSS series FSS series The Pipe Section is constructed of copper alloy and fitted with BSP/NPT threads from 15

More information

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters Product Data Sheet Non-contacting measurement with no moving parts Fast and simple to install and configure Continuous measurement of level, contents (volume), or open channel flow MCERTS certified version

More information

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm) http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made

More information

HFID Heated Total Hydrocarbon Analyzer Module

HFID Heated Total Hydrocarbon Analyzer Module Product Data Sheet PDS 103-685.A01 October, 2003 NGA 2000 HFID Heated Total Hydrocarbon Analyzer Module Heated analyzer designed to operate from 200 F to 400 F Eliminates loss of hydrocarbons due to condensation

More information

Rosemount 2051 Pressure Transmitter

Rosemount 2051 Pressure Transmitter Rosemount 2051 Pressure Transmitter Product Data Sheet April 2013 00813-0100-4101, Rev JA Coplanar platform enables integration of primary elements, manifolds, and remote seal solutions Best in Class performance

More information

Rosemount 2051T In-Line Pressure Transmitter

Rosemount 2051T In-Line Pressure Transmitter Rosemount 2051T In-Line Pressure Transmitter 2051T In-Line Wireless Pressure Transmitter Configuration Transmitter Output Code 4-20 ma HART 2051 A 2051 with Selectable HART (1) Lower Power 2051 2051 with

More information

RK-05 Combustible Gas Transmitter Operator s Manual

RK-05 Combustible Gas Transmitter Operator s Manual 65-2405RK-05 Combustible Gas Transmitter Operator s Manual Part Number: 71-0180RK Revision: 0 Released: 2/16/11 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction

More information

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP...world leaders in heat transfer technology The Basic Operation of Type T and TC Separators Basco Type T and TC Separators are designed to remove entrained

More information

CLARITY II TURBIDIMETER

CLARITY II TURBIDIMETER Product Data Sheet PDS 71-T1055/rev.J January 2006 Model T1055 CLARITY II TURBIDIMETER COMPLETE SYSTEM includes single or dual input analyzer, sensor(s), and debubbler assembly CHOOSE U.S. EPA METHOD 180.1

More information

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery Ramsey Series 60-200 Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery Ramsey Series 60-200 Motion Monitoring Systems offer versatile and reliable packages

More information

BBSS BASIC BOTTLE SAMPLING SYSTEM

BBSS BASIC BOTTLE SAMPLING SYSTEM N BBSS BASIC BOTTLE SAMPLING SYSTEM The SENSOR Basic Bottle Sampling System (BBSS), is a closed loop liquid sampler that is ideal for processes with pressure less than 150 psig and process temperature

More information

Rosemount 3051L Level Transmitter

Rosemount 3051L Level Transmitter Rosemount 3051 December 2013 Rosemount 3051L Level Transmitter The Rosemount 3051L Level transmitter combines the performance and capabilities of Rosemount 3051 transmitters with the reliability and quality

More information

SECTION METERS AND GAGES FOR HVAC PIPING

SECTION METERS AND GAGES FOR HVAC PIPING SECTION 23 0519 METERS AND GAGES FOR HVAC PIPING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Thermometers. 2. Gages. 3. Test plugs. 4. Thermowells. 1.2 SUBMITTALS A. Product Data: For each type

More information

MT3809G Series. Data Sheet. Metal Tube Variable Area Flowmeters. Overview. Product Description. Variable Area

MT3809G Series. Data Sheet. Metal Tube Variable Area Flowmeters. Overview. Product Description. Variable Area Data Sheet MT3809G Series MT3809G General Purpose Housing Variable Area Metal Tube Variable Area Flowmeters Overview Brooks MT3809 meter operation is based on the variable area principle. The all metal

More information

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

Advanced Laundry Chemical Dosing System for Single and Multi-Washers Advanced Laundry Chemical Dosing System for Single and Multi-Washers The On-Premise Elite sets the new standard for laundry chemical dosing systems by which all others will be measured! Innovative smart

More information

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface Multi Parameter flow meters provide accurate data on three different fluid parameters: flow pressure temperature The flow rate can be displayed in volumetric flow or mass flow engineering units for standard

More information

Enraf Servo Gauge 854 XTG

Enraf Servo Gauge 854 XTG Enraf Servo Gauge 854 XTG Cut costs, not repeatability. Honeywell s 854 XTG servo gauge is a high performance alternative to other tank level measurement technologies such as radar tank level gauges. It

More information

Rosemount 3100 Series Ultrasonic Level Transmitters

Rosemount 3100 Series Ultrasonic Level Transmitters Product Data Sheet Ultrasonic Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for on-site programming Continuous measurement of level or distance-to-surface.

More information

America s Most Versatile Line of Centrifugal Pumps

America s Most Versatile Line of Centrifugal Pumps America s Most Versatile Line of Centrifugal Pumps OEM Development Price Pump Co. has a storied history of developing products specific to the requirements of many original equipment manufacturers in industry

More information

SECTION METERS AND GAGES FOR PLUMBING PIPING

SECTION METERS AND GAGES FOR PLUMBING PIPING SECTION 220519 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Rosemount 2051 Pressure Transmitter

Rosemount 2051 Pressure Transmitter Rosemount 2051 Pressure Transmitter Product Data Sheet May 2016 00813-0100-4101, Rev KB Rosemount Coplanar platform enables integration of primary elements, manifolds, and remote seal solutions Best in

More information

Rosemount 3051 Pressure Transmitter

Rosemount 3051 Pressure Transmitter Rosemount 3051 Pressure Transmitter Product Data Sheet April 2014 00813-0100-4001, Rev RC With the Rosemount 3051 Pressure Transmitter, you ll gain more control over your plant. You ll be able to reduce

More information

SERVICE MANUAL. 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and Model

SERVICE MANUAL. 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and Model Section: MOYNO 500 PUMPS Page: 1 of 4 Date: March 1, 1998 SERVICE MANUAL MOYNO 500 PUMPS 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and 36752 Model DESIGN FEATURES Housing: Cast iron/316 SS

More information

Laser Collimated Beam Sensor

Laser Collimated Beam Sensor SERIES Laser Collimated Beam Sensor Class 1 Laser Beam Sensor Safe for Your Eyes Marked Conforming to EMC Directive (Excluding LA-C1) Safe Laser Beam This laser collimated beam sensor conforms to the Class

More information

Pre-engineered Sample Systems for TALYS ASP400 series with fiber optic interface

Pre-engineered Sample Systems for TALYS ASP400 series with fiber optic interface DS/TALYS/ASP400-EN Pre-engineered Sample Systems for TALYS ASP400 series with fiber optic interface The TALYS ASP400 series FT-NIR analyzer is designed to offer a simple base analyzer with a range of pre-engineered

More information

Retractable ph/orp Sensor

Retractable ph/orp Sensor Instruction Sheet PN 51A-398R/rev.H January 2011 Model 398R Retractable ph/orp Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. SPECIFICATIONS Measurements

More information

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data W A T L O W The Watlow FIREROD not only set the industry standard for cartridge heaters, it continues making improvements in construction and design. Among those improvements is the metric FIREROD, a variation

More information

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes 1129 PHOTO PHOTO PARTICUR Sensor SERIES Related Information General terms and conditions... F-3 About laser beam... P.193~ guide... P.121~ General precautions... P.19 Conforming to FDA regulations (-11

More information

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS. SERVOTOUGH FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS Flexible Can be used in hazard rated locations including Zone

More information

600 Series Spin-on Fuel Filter/Water Separators

600 Series Spin-on Fuel Filter/Water Separators 600 Series Spin-on Fuel Filter/Water Separators Instruction Part Number 2229 Rev B 600 Series fuel filter/water separators are specifically designed to handle today s tough fuel filtration problems and

More information

RK CO 2 Transmitter Operator s Manual

RK CO 2 Transmitter Operator s Manual 65-2397RK CO 2 Transmitter Operator s Manual Part Number: 71-0185RK Revision: B Released: 7/18/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual before

More information

RK-02 Multi Point Detector Operator s Manual

RK-02 Multi Point Detector Operator s Manual 65-2485RK-02 Multi Point Detector Operator s Manual Part Number: 71-0237RK Revision: A Released: 11/26/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

RK / RK CO 2 Detector Operator s Manual

RK / RK CO 2 Detector Operator s Manual 61-1004RK / 61-0191RK CO 2 Detector Operator s Manual Part Number: 71-0145RK Revision: C Released: 10/29/18 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating detector.

More information

Absolute and Gage Pressure Transmitter

Absolute and Gage Pressure Transmitter Product Data Sheet 0083-000-4699 Absolute and Gage Pressure Transmitter ATRADITION OF EXCELLENCE IN THE PULP AND PAPER INDUSTRY Mounts flush to process media -inch flush mount compatible with a PMC process

More information

Ramsey Motion Monitoring Systems

Ramsey Motion Monitoring Systems Ramsey Motion Monitoring Systems 60-200 Motion Monitoring Accurate Sensing of Underspeed, Overspeed and Zero Speed Conditions on Rotating Shafts and Machinery The Ramsey Series 60-200 Motion Monitoring

More information

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery Thermo Scientific Ramsey TM Series 60-200 Sensing Speed Conditions on Rotating Shafts and Machinery The Thermo Scientific Ramsey Series 60-200 monitors under-speed, overspeed and zero-speed conditions

More information

Pressure-Resistant and Explosion-Proof Electric Contact Pressure Gauges and Pressure Switches

Pressure-Resistant and Explosion-Proof Electric Contact Pressure Gauges and Pressure Switches CATALOG No. 3150 MODEL No. AdC No. AdS Pressure-Resistant and Explosion-Proof Electric Contact Pressure Gauges and Pressure Switches AdC-Type Pressure Gauges with Contact AdC-WType Differential Pressure

More information

Electronic Flow Switches

Electronic Flow Switches Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

Series 5000 Hydrazine Analyzer Model 60002

Series 5000 Hydrazine Analyzer Model 60002 Series 5000 Hydrazine Analyzer Model 60002 T he patented* Series 5000 Hydrazine Analyzer is a continuous-reading instrument using the p-dimethylaminobenzaldehyde method of analysis for colorimetric measurement

More information

Ultrasonic Switches. Features & Benefits

Ultrasonic Switches. Features & Benefits Why use an ultrasonic switch over other level technologies? Depending upon your application, there may be three or four technologies equally suited for your application; however; only one will be the best

More information

Technical Information OUSTF10

Technical Information OUSTF10 TI00500C/07/EN/01.13 71157320 Products Solutions Services Technical Information Optical sensor combined with flow assembly OUA260 for measurement of turbidity and non-dissolved solids Application The scattered

More information

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT Refrigerating Desiccant High polymer membrane dryer VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT JIS symbol Air filter Auto. drain (Module unit) (Separate) Compact Precise (Related

More information

M5200 Industrial Pressure Transducer

M5200 Industrial Pressure Transducer SPECIFICATIONS Wide Temperature Range Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber CE Compliant and Weatherproof UL Certified Gage, Sealed, Compound

More information

MAXI-VENT Air Admittance Valve

MAXI-VENT Air Admittance Valve MAXI-VENT Air Admittance Valve Manufacturer: Studor, Inc. Connec on Size: 3 or 4 Model #: MAXI VENT Item #: 20302 An air admittance valve shall be acceptable as a vent termination for any individual vent,

More information

UW Purchase Specification Section Steam Condensate or Hot Water Meter Page 1 of 9

UW Purchase Specification Section Steam Condensate or Hot Water Meter Page 1 of 9 Page 1 of 9 PART 1 GENERAL 1.02 DESCRIPTION A. Purpose 1. This section covers steam condensate meters, steam condensate sub-meters and hot water sub-meters for use in the Owner's steam systems. 1.03 QUALIFICATIONS

More information

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74 AM54 Instruction Bulletin North American Installation Addendum Document Number PN25016 Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

More information

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS 230500 HVAC BASIC MATERIAL AND METHODS PART 1 GENERAL 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS A. Section 230000 Basic HVAC Requirements B. Section 230523 Valves C. Section 230510 Chilled

More information

air.iq Moisture Analyzer Packaged Solution GE Measurement & Control Applications Features

air.iq Moisture Analyzer Packaged Solution GE Measurement & Control Applications Features GE Measurement & Control air.iq Moisture Analyzer Packaged Solution Features Applications air.iq simplifies the selection and installation of your moisture analyzer. Install the moisture probe, wire your

More information

Combustible Gas Sample-Draw Detector Operator s Manual

Combustible Gas Sample-Draw Detector Operator s Manual 35-3001-01 Combustible Gas Sample-Draw Detector Operator s Manual Part Number: 71-0282RK Revision: A Released: 8/3/17 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information