FAHM Co. Temperature Transmitter PTT74 Series

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "FAHM Co. Temperature Transmitter PTT74 Series"

Transcription

1 FAHM Co. PTT74 Series The PTT74 is a versatile temperature transmitter that delivers field reliability and advanced accuracy and stability to meet demanding process needs. PTT74 Family of Transmitters Fit your needs within one model family with a customizable transmitter design DIN Head mount and Rail mount form factors 4-20 ma /HART with Selectable Revisions Enhanced Display with Local Operator Interface LCD Display Integrated Transient Protection Enhanced Accuracy and Stability Variety of enclosures Page 1

2 PTT74 HART transmitters PTT74 is a smart 2-wire transmitter for temperature and other universal input measurement applications. Is fully HART-compatible. Provides excellent flexibility, low storage and installation costs. The high reliability ensures a safe system operation and low maintenance costs. Input Resistance thermometer (2,3,4 wire circuit) Thermocouples B,C,E,J,K,L,N,R,S,T,U Resistance remote signaling Unit( Ohm) Voltage, mv ( mv) Output 2-wire technique 4 20 ma Operating Temperature -40 C to 85 C Electrical isolation between input and output(i/o Isolation) Digital low drift processing of measurement values Customer specific linearization 32 tie points Continuous sensor self-monitoring Parameters saved permanently in EEPROM Monitoring of ADC and DAC parameters every 1 sec Wire break monitoring acc. With NAMUR NE 89 Dual Input functionality Absolute, differential, average values Parameterization (Software configuration) Smartware Calibration Tools (SCT) Siemens PDM Software ABB SMART VISION Software Hand held terminal: DHH691, 691HT, STT04, HC275, HC374, HC475 Approval for explosion protection Intrinsically safe II 2 G EEx ib IIC T6, mount in zone 1 II 3 G EEx na II T6, mount in zone 2 Page 2

3 Ordering Information: Model PTT74 Product Description Temperature transmitter Transmitter Type H R Head Mounted Rail Mounted Channel Types Head Rail A Single Channel B Dual Channel - Transmitter Output Head Rail A 4 20 ma with Digital Signal Based on HART Protocol - Product Certifications Head Rail NA No approval I1 ATEX Intrinsic Safety E1 ATEX Explosion Proof - N1 ATEX Type n K1 ATEX Intrinsic Safety; Type n KA ATEX Explosion Proof; Intrinsic Safety; Type n - Enclosure Material Entry Size Process Head Rail H0 No Additional Enclosure H1 H2 H3 Universal Connection Head with 1 Elec. Entry Universal Connection Head with 2 Elec. Entries Universal Connection Head with 2 Elec. Entry and Glass Window for Local Indicator Aluminum M20 x 1.5 ½ NPT - Aluminum M20 x 1.5 ½ NPT - Aluminum M20 x 1.5 ½ NPT - Mounting Bracket Option Head Rail B4 316 SST U-bolt Mounting Bracket, 2-in pipe mount - Display and Interface Option Head Rail M4 LCD Display with Local Operator Interface - M5 LCD Display - Software Configuration Option Head Rail C1 Custom Configuration of Date, Descriptor and Message (Requires CDS with order) Alarm Level Configuration Option Head Rail A1 NAMUR alarm and saturation levels, high alarm CN NAMUR alarm and saturation levels, low alarm Line Filter Option Head Rail F5 50 Hz Line Voltage Filter Page 3

4 F6 60 Hz Line Voltage Filter 5-Point Calibration Option Head Rail C4 5-point calibration. Use option code Q4 to generate a calibration certificate Calibration Certificate Option Head Rail Q4 Calibration certificate. 3-Point calibration with certificate External Label Option Head Rail EL External label for ATEX Intrinsic Safety Assemble Sensor Option Head Rail XA Sensor Specified Separately and Assembled to Transmitter Typical Rail Mount Model Number: PTT74-R-A-K1-H0-T0 Typical Head Mount Model Number: PTT74-H-A-K1-H3-T2 B4 M4 Page 4

5 Technical Overview PTT74 Output Output signal (temperature linear) 4 20 ma Residual ripple(peak-to-peak) < 5 ua Nonlinearity Error < % Current consumption < 3.6 ma Max. Output current 23.6 ma Load resistance < 1 K Ω Parameterizable Current error signal Under ranging 3.6 ma Over ranging 22 ma Default Value 3.6 ma ma Input Resistance Resistance thermometer n Pt100/Ni100/CU100 to Pt1000/Ni1000/Cu1000 (n = 0.1, 0.2, 0.5, 1, 1.2, 2, ) Resistance / Measuring current 210µA Sensor short-circuit < 5 (for RTD) Input Filter 50/60 Hz Thermocouples Types B,C,E,J,K,L,N,R,S,T,U Voltages -125 mv mv Open circuit test current 100nA Cold junction compensator Type PT100, via software switchable Resolution 0.01 C Accuracy 0.05 C (After software calibration ) Programming Method Protocol HART Programming Software Device Management Tool Handheld Terminal (DHH691, 691HT, STT04, HC275, HC374, HC475 ) HART Modem (FAHM Co. SMARTWARE Calibration Tool, ABB SmartVision Software, Siemens PDM Software) SCT Calibration Algorithms Linearization SCT Parameter Sensor type, measuring range, Calibration Algorithm, error signaling, Compensating switch,general characteristics (i.e. TAG name), Signal simulation of compensator, input and output, Output monitoring(trend viewer), Device Diagnostic Mechanical construction Weight 65 g (Head Mounted without enclosure) 235 g (Rail Mounted) Housing material/color Polyamide / Yellow Electrical connection Terminals, pluggable 2.5 mm2,screw terminals Page 5

6 General characteristics Output signal refreshment rate With sensor monitor Resistance: 0.7 s Thermocouple: 0.5 s Without sensor monitor Resistance: 0.5 s Thermocouple: 0.3 s Electrical isolation (I/O/P) 1 kv AC(60s) Long-term stability < 0.1 % p.a. Environment conditions Ambient temperature range C Transport and storage temperature C Relative humidity < 100% (100% humidity with isolated terminals only) Condensation Permitted Power Supply Supply voltage For Ex application: VDC For non Ex application VDC Max residual ripple < 1 % Us (<500Hz) Influence of supply voltage ±0.01 % / 10V Accuracy PT100 Thermocouples Resistance 500Ω/5000Ω Voltage 120mV/1200mV Explosion protection Intrinsically safe Zone 1 ±0.1 K ±20uV ±20 mω/±100 mω ±20 uv /± 50uV Marking II 2 G EEx ib IIC T6 Temperature Class T6/T5/T4 < 50 C /65 C /85 C Supply Circuit Output Measuring Max Voltage Ui = 29.4 V Uo=5 V Short-circuit current Ii = 130 ma Io=3.2 ma Max Power Pi = 0.8 W Po=16 mw Internal inductance Li= 240 uh L0=1 mh Internal capacitance Ci= 10 nf Co=10uF Zone 2 Marking II 3 G EEx n A II T6 Temperature Class T6/T5/T4 < 50 C /65 C /85 C Page 6

7 Measuring Ranges Input Element Standard Sensor Measuring Range Min. Measuring span Thermocouple type B C ( F) 235 C (423 F) Thermocouple type E C ( F) 30 C ( 54 F) Thermocouple type J C ( F) 37 C ( 67 F) IEC 584_1 Thermocouple type K C ( F) 54 C ( 98 F) Thermocouple type R C ( F) 171 C (308 F) Thermocouple type S C ( F) 193 C (348 F) Thermocouple type T C ( F) 50 C ( 90 F) Thermocouple type N C ( F) 60 C (108 F) DIN Thermocouple type U C ( F) 36 C ( 65 F) Thermocouple type L C ( F) 40 C ( 72 F) W3, ASTME 998 Thermocouple type C C ( F) 163 C ( 294 F) Thermocouple type D C ( F) 135 C ( 243 F) IEC 751; JIS; SAMA 1 Resistance thermometer Pt C ( F) 15 C ( 28 F) 2-3 and 4 wire Resistance thermometer Pt C ( F) 50 C ( 90 F) DIN 43760² Resistance thermometer Ni C ( F) 8 C ( 15 F) 2,3 and 4 wire Resistance thermometer Ni C ( F) 15 C ( 28 F) Resistance Ω /50 5Ω / 5Ω Voltage mv 125 mv mv 2 mv 125 mv mv 50 mv 1) IEC 751 a = , JIS a = , SAMA a = ) Edison Curve No. 7 Page 7

8 PTT74 Head Mounted Dimensional Diagram Only used the M3 4.5 mm screws supplied or screws of the same type for the connecting terminals. Longer screws will damage the transmitter. In this case, the explosion-proof PTT74-Ex transmitter is no longer protected against explosions and its certification is rendered invalid. PTT74 Head Mounted Connection Diaphragm PTT74 Head Mounted Hart Configuration Diagram Page 8

9 PTT74 Rail Mounted Dimensional Diagram PTT74 Rail Mounted Connection Diaphragm PTT74 Rail Mounted Hart Configuration Diagram Page 9

10 Schematic Drawings Explosion View PTT74-H3 Page 10

11 Explosion View PTT74-H3 Page 11

12 Explosion Viwe PTT74-H1 Page 12

13 Dimensional View PTT74-H2 & H3 Dimensional View of Brackets PTT74-H2 Page 13

14 Product Certifications: PTT74: II 2 G Ex ib IIC T6, II 3 G, Ex na II T6, T6(Ta +50 C) Rated Voltage: V Output Signal: 4-20 ma I1 ATEX Intrinsic Safety; Type n Certificate: CESI 09 ATEX 049X Standards: EN : 2006, EN : 2007, EN :2005 Intrinsically safe II 2 G Ex ib IIC T6, mount in zone 1 II 3 G Ex na II T6, mount in zone 2 FAHM Co. FARABOARD HOUSHMAND MIHAN Main Office: Unit 8, 4th Floor, No.37, Tohid St., Tehran, Iran Tel: Fax: Factory: Garmsar Industrial Zone, Sanat 2 St. Page 14

Operating Instructions Edition 02/2007

Operating Instructions Edition 02/2007 Operating Instructions Edition 02/2007 Temperature Transmitter 7NG3214 with PROFIBUS PA 7NG3215 with FOUNDATION Fieldbus sitrans Introduction 1 General safety notes 2 SITRANS T Temperature transmitter

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 Introduction Honeywell s STT 3000 family of microprocessor based transmitters covers the full

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

Rosemount 3051CFC Compact Flowmeter

Rosemount 3051CFC Compact Flowmeter CFC Compact Flowmeter CFC Compact Flowmeters provide a quick, reliable installation between existing raised face flanges. Depending on your application needs, you can reduce energy loss with the Compact

More information

Rosemount 248 Temperature Transmitter

Rosemount 248 Temperature Transmitter Product Data Sheet March 2017 00813-0100-4825, Rev LA Rosemount 248 Temperature Transmitter Basic temperature transmitter offers a reliable solution for temperature monitoring points. Standard transmitter

More information

Rosemount 248 Temperature Transmitter

Rosemount 248 Temperature Transmitter Product Data Sheet January 2018 00813-0100-4825, Rev LB Rosemount 248 Temperature Transmitter Basic temperature transmitter offers a reliable solution for temperature monitoring points. Standard transmitter

More information

SITRANS T temperature transmitters A broad product family for every application. sitrans

SITRANS T temperature transmitters A broad product family for every application. sitrans SITRANS T temperature transmitters A broad product family for every application sitrans The SITRANS T family High-precision, intrinsically safe, and available for a wide variety of sensors Whether you

More information

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses. General information 1 Marking of the degree of protection 2 SITRANS T SITRANS T Explosion protected temperature sensor Operating Instructions Range of uses 3 Installation 4 Assembly and disassembly 5 Commissioning

More information

MODEL APT 3700N. Smart Pressure Transmitter For Nuclear Service. Duon System Co., Ltd. for Differential / Gauge / Absolute Pressure Measurement

MODEL APT 3700N. Smart Pressure Transmitter For Nuclear Service. Duon System Co., Ltd. for Differential / Gauge / Absolute Pressure Measurement DOC. NO. : 3700N-E01I For Nuclear Service for Differential / Gauge / Absolute Pressure Measurement MODEL APT 3700N (GASAN-DONG), 232, BEOTKKOT-RO GUMCHON-GU SEOUL KOREA Tel : +82-2-860-7900 Fax : +82-2-860-7997

More information

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements Specifications COMMANDER 150 Universal Process Indicator High visibility 6-digit LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER MODEL AH3 7 P - - A AH3000 series conforming to CE, UL and CSA are 180mm pen type hybrid recorders with a simultaneous display of multi-channel data,

More information

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1 emperature Multi-Input Device for Cabinet Installation Features Assembly For 8 temperature or analog sensors Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus

More information

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2 APT 2000 Series 2-Wire ph Transmitters 70-82-03-32 2/00 Page 1 of 8 Specification Overview The Honeywell Analytical Process Transmitter (APT) 2000 Series transmitter is a two-wire 24-Volt device that continuously

More information

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 2088 Absolute and Gage Pressure Transmitter Product Data Sheet Rosemount 2088 Rosemount 2088 Absolute and Gage Pressure Transmitter Absolute and gage pressure ranges from 0 1.5 psi to 0 4,000 psi (0 0.1 to 0 276 bar) Performance of 0.075% with high

More information

Rosemount 3051S Series of Instrumentation

Rosemount 3051S Series of Instrumentation Product Data Sheet October 2017 00813-0100-4801, Rev UG Rosemount 3051S Series of Instrumentation Scalable pressure, flow, and level solutions Innovation reaching across your operation With the Rosemount

More information

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 2090F Hygienic Pressure Transmitter Hygienic Pressure Transmitter Conforms to 3-A Sanitary s Features CIP/SIP service for process temperatures up to 284 F (140 C) Absolute or gage pressure ranges from 0-1.5 to 0-300 psi Mounts with either

More information

Rosemount 848T High Density Temperature Measurement Family

Rosemount 848T High Density Temperature Measurement Family Product Data Sheet July 2017 00813-0100-4697, Rev PA Rosemount 848T High Density Temperature Measurement Family Innovative temperature measurement for high density applications that provide installation

More information

Rosemount 2090P Pulp and Paper Pressure Transmitter

Rosemount 2090P Pulp and Paper Pressure Transmitter Product Data Sheet Rosemount 2090P Pulp and Paper Pressure Transmitter Rosemount 2090P 1-inch flush mount compatible with a PMC process connection, or 1 1 /2-inch threaded mounting connection Absolute

More information

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level Measurement Continuous level measurement - Ultrasonic transmitters Overview Configuration Parabolic mounting is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels, and simple process vessels.

More information

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width) SBEx-4 BISTATE SEPARATOR,, 3 or 4 channels in rail housing (TS3,,mm width) - group I category (M), group II and III category () accompanying device, - intrinsically safe input circuits with ia protection

More information

Rosemount 3051SFC Compact Orifice Flowmeter

Rosemount 3051SFC Compact Orifice Flowmeter Rosemount Compact Orifice Product Data Sheet Rosemount 3051SFC Compact Orifice Flowmeter SPECIFICATIONS Performance System Reference Accuracy Percent (%) of volumetric flow rate TABLE 1. 3051SFC Compact

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output

More information

Rosemount 4500 Hygienic Pressure Transmitter

Rosemount 4500 Hygienic Pressure Transmitter Product Data Sheet Rosemount 4500 Rosemount 4500 Hygienic Pressure Transmitter Hygienic design conforms to 3-A and EHEDG standards Demonstrated best-in-class performance during SIP/CIP for process temperatures

More information

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC Engineering Guideline pac-carriers Type 9195 for TRICON system TRICONEX TMR PLC 2 Engineering Guideline TRICON system 14.10.2009 Content Signal type Control system I/O cards type pac-carrier Channels Slots

More information

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C) Product Data Sheet December 2012 00813-0100-4027, Rev BB Rosemount 4500 Hygienic Pressure Transmitter ProductDiscontinued R 37-01 Hygienic design conforms to 3-A and EHEDG standards Demonstrated best-in-class

More information

SPA 2 IS. IECEx. Programmable Limit Alarm Trips with Intrinsically-Safe Field Connections

SPA 2 IS. IECEx. Programmable Limit Alarm Trips with Intrinsically-Safe Field Connections April 2016 Description The universal SPA 2 IS Programmable Limit Alarm Trips provide on/off control, warn of unwanted process conditions, alarm on rate-of-change and provide emergency shutdown. Very versatile,

More information

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors Instructions manual Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors HB Products A/S Bøgekildevej 21 DK8361 Hasselager support@hbproducts.dk www.hbproducts.dk

More information

Section B Field Instruments

Section B Field Instruments 91-00-01-01 Section B Field Instruments Contents Product Type Literature No. Overview 30-00-02-01 34 ST 3000 Series 100e Smart Pressure s SMV 3000 Smart Multivariable Model STM125 Series 100e Models Series

More information

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 2090F Hygienic Pressure Transmitter Rosemount 2090F Hygienic Pressure Transmitter Product Data Sheet November 2016 00813-0100-4698, Rev FC Conforms to 3-A Sanitary Standards Features CIP/SIP service for process temperatures up to 284 F (140

More information

Annubar Flowmeter Series

Annubar Flowmeter Series Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA

More information

Ar-Mite TM Low Flow Armored Flowmeter

Ar-Mite TM Low Flow Armored Flowmeter Data Sheet Brooks Ar-Mite TM MT 3750C Ar-Mite TM Low Flow Armored Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm

More information

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 2090F Hygienic Pressure Transmitter Rosemount 2090F Hygienic Pressure Transmitter Product Data Sheet December 2017 00813-0100-4698, Rev GA Conforms to 3-A Sanitary Standards Features CIP/SIP service for process temperatures up to 284 F (140

More information

Low Temperature Zirconia Oxygen Analyzer

Low Temperature Zirconia Oxygen Analyzer Data Sheet SS/ZDT FG Issue 10 Low Temperature Zirconia Oxygen Analyzer ZDT FG Environmental certification MCERTS SIRA certificate MC99000 1/00 User-friendly language options selectable system alarms comprehensive

More information

Rosemount 3051CF DP Flowmeters

Rosemount 3051CF DP Flowmeters Product Data Sheet June 2013 00813-0300-4485, Rev EC Rosemount 3051CF DP Flowmeters Up to 1.80% volumetric flow accuracy at 8:1 turndown Available with HART, FOUNDATION fieldbus, and Profibus Protocols

More information

SmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information.

SmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information. SmartLine Technical Information RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December 2015 Introduction The Honeywell RMA803 is a Foundation Fieldbus remote indicator suitable

More information

VERSAFLOW VORTEX Supplementary instructions

VERSAFLOW VORTEX Supplementary instructions VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according

More information

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document A190325 Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document CONTENTS INTRODUCTION 1. DUAL CERTIFIED COMPONENTS 1.1 Simple Apparatus Switches For

More information

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION Special Safety Instruction en RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION Contents TankRadar Pro European ATEX Directive Information............................... 2 ATEX marking and Ex Certification

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm

More information

Rosemount 3051 Pressure Transmitter

Rosemount 3051 Pressure Transmitter Rosemount 3051 Pressure Transmitter Product Data Sheet December 2017 00813-0100-4001, Rev TB With the Rosemount 3051 Pressure Transmitter, you ll gain more control over your plant. You ll be able to reduce

More information

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74 AM54 Instruction Bulletin North American Installation Addendum Document Number PN25016 Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

More information

02/11/2015

02/11/2015 CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit ABB MEASUREMENT & ANALYTICS DATA SHEET C50 1/16 DIN controller / alarm unit 2 C50 1/16 DI N CON TROLL ER / AL ARM U NIT DS/C 50-E N RE V. M Measurement made easy C50 the 1/16 DIN controller to suit your

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 8 mm non-flush Stainless steel housing Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 8 mm

More information

Dräger Polytron 7000 Fixed gas detector

Dräger Polytron 7000 Fixed gas detector DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger Polytron 7000 Fixed gas detector ST-3751-2003 The Dräger Polytron 7000 is a gas detector that can satisfy all toxic and

More information

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO PROZESSAUTOMATION Manual SEGMENT PROTECTOR R-SP-!12 FieldConnex TM Segment Protectors with overloaod protection and short-circuit current limitation for the connection of 12 field devices Zone 1 Zone 2

More information

PRESSURE TRANSMITTERS

PRESSURE TRANSMITTERS TABLE OF CONTENTS Honeywell was a pioneer in smart transmitter technology more than 20 years ago. Now, the SmartLine transmitters are even better: faster, more accurate, with a display that helps you diagnose

More information

3500/61E & 3500/67E Temperature Monitor

3500/61E & 3500/67E Temperature Monitor 3500/61E & 3500/67E Temperature Monitor Bently Nevada* Asset Condition Monitoring Description The 3500/61E and 3500/67E modules provide six channels and two channel of temperature monitoring. Both monitors

More information

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Universal controller for panel mounting Models CS6S, CS6H, CS6L Accessories Universal controller for panel mounting Models CS6S, CS6H, CS6L WIKA data sheet AC 85.08 Applications Plant and industrial furnace construction Process engineering Plastics technology and processing

More information

BA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13

BA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13 TR Automatyka Sp. z o. o. Tel. (+48 022) 886 10 16 www.trautomatyka.pl ul. Lechicka 14 ; 02-156 Warszawa Fax. (+48 022) 846 50 37 biuro@trautomatyka.pl BA334D Intrinsically safe Externally powered pulse

More information

USER GUIDE FOR GASSONIC SURVEYOR ULTRASONIC GAS LEAK DETECTOR

USER GUIDE FOR GASSONIC SURVEYOR ULTRASONIC GAS LEAK DETECTOR T E C H N I C A L D O C U M E N T A T I O N USER GUIDE FOR GASSONIC SURVEYOR ULTRASONIC GAS LEAK DETECTOR CONTENTS 1.0 The Gassonic Surveyor....................................... 3 1.1 Application..............................................

More information

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration Planning and configuration of the I.S. 1 system 5 ENGINEERING 5.1 Safety instructions for system configuration and explosion protection During engineering, comply with the guidelines set out in EN 60 079-14.

More information

ST Pressure Transmitter. Operator Manual. Doc. No.: 34-ST Issue: 2.1 Last Revision Date: 03/04. Industrial Measurement and Control

ST Pressure Transmitter. Operator Manual. Doc. No.: 34-ST Issue: 2.1 Last Revision Date: 03/04. Industrial Measurement and Control ST 2000 Pressure Transmitter Operator Manual Doc. No.: 34-ST-11-21 Issue: 2.1 Last Revision Date: 03/04 Industrial Measurement and Control Notices and Trademarks Warranty/Remedy Copyright 2003 by Honeywell

More information

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Mass Flow Computers Series 155 The Kurz 155 Mass Flow Computer is a versatile system transmitter that integrates the functions of flow and temperature measurement, flow totalization,

More information

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration Level instruments Overview Configuration is a compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam. Benefits

More information

OilSET-1000 (12 VDC)

OilSET-1000 (12 VDC) Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 Internet: www.labkotec.fi 20.03.2009 1/11 OilSET-1000 (12 VDC) Oil Separator Alarm Device Copyright 2009

More information

Rosemount 2051CF DP Flowmeters

Rosemount 2051CF DP Flowmeters Product Data Sheet June 2013 00813-0400-4485, Rev EC Rosemount 2051CF DP Flowmeters Up to 2.00% volumetric flow accuracy at 5:1 turndown Available with HART and FOUNDATION fieldbus Protocols 2-year stability

More information

INTRINSICALLY SAFE S314X AND S315X

INTRINSICALLY SAFE S314X AND S315X INTRINSICALLY SAFE S314X AND S315X Ex SERIES DUST MONITORS Atex models S314X and S315X are not TUV approved versions User Manual Distributor Version 1.3 9.9.2009 Table of Contents 1. INTRODUCTION... 3

More information

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems HC-100 Gas Measuring and Alarm Systems HC-100 Application / Construction The HC100 series of measuring probes, used in conjunction with evaluation systems, have the following functions: Measurement and

More information

Level Measurement Continuous level measurement Ultrasonic transmitters

Level Measurement Continuous level measurement Ultrasonic transmitters Overview Configuration is a short-range integrated ultrasonic level transmitter. This intrinsically safe, 2 wire, 4 to 20 ma loop powered transmitter is ideal for liquids, slurries, and bulk materials

More information

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660 Selectivity Adjustable by Means of - High Pass Frequency Filter - Gain - Threshold Different Adjustments for Different Conditions (e.g. According Fuel or Combustion Technology) Possible, to be Activated

More information

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward Foundation Fieldbus End Users Council Australia Inc. 9 Corcoran St Duncraig, WA 6023 P.O.Box Z5546 Perth, WA 6831 AUSTRALIA ABN 60 120 236 370 Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and

More information

89BSD Digital Output

89BSD Digital Output SPECIFICATIONS Stainless Steel with O-Ring Seal Pressure/Temperature Read-Out (24-bit DS ADC) ASIC Calibrated Absolute, Sealed Gage 9mm Diameter The 89BSD is a 9mm diameter small profile, media compatible,

More information

SET Installation and Operating Instructions. Level switch for one sensor

SET Installation and Operating Instructions. Level switch for one sensor Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel.: +358 29 006 260 Fax: +358 29 006 1260 7.11.2013 Internet: www.labkotec.fi 1/14 SET-1000 Level switch for one sensor Copyright 2013 Labkotec Oy

More information

Brooks MT3750 Low Flow Armored Flowmeter

Brooks MT3750 Low Flow Armored Flowmeter Brooks MT3750 Low Flow Armored Flowmeter ArMite TM Model MT3750 Metal Tube Flowmeter ArMite TM Model MT3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm Benefits: Wetted Parts made from Stainless

More information

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR SAFETY MANUAL SIL 2 Certified Model FP-700 Combustible Hydrocarbon Gas Sensor Version 2.0 1 SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR This manual addresses the specific requirements and recommendations

More information

ProcessMaster, HygienicMaster FEX300, FEX500

ProcessMaster, HygienicMaster FEX300, FEX500 SM/FEX300/FEX500/ATEX/IECEX-EN ProcessMaster, HygienicMaster FEX300, FEX500 ATEX / IECEx Zone 1, 2, 21, 22 Safety instructions for electrical apparatus in potentially explosive areas, in accordance with

More information

Rosemount 3051 Pressure Transmitter Includes Transmitter Option TR ProductDiscontinued. Start

Rosemount 3051 Pressure Transmitter Includes Transmitter Option TR ProductDiscontinued. Start Quick Installation Guide June 2009 Rosemount 3051 Rosemount 3051 Pressure Transmitter Includes Transmitter Option TR ProductDiscontinued Start Step 1: Mount the Transmitter Step 2: Consider Housing Rotation

More information

Intelligent sensing for every temperature and condition

Intelligent sensing for every temperature and condition More information: www.siemens.com/sitranst www.siemens.com/processinstrumentation siemens.com/sitranst Siemens Industry, Inc. 3333 Old Milton Parkway Alpharetta, GA 30005 1-800-241-4453 info.us@siemens.com

More information

Microprocessor Based 16 Channel Temperature Scanners (Product Code 7.2 To 7.3) MSI-16-H

Microprocessor Based 16 Channel Temperature Scanners (Product Code 7.2 To 7.3) MSI-16-H Microprocessor Based 16 Channel Temperature Scanners (Product Code 7.2 To 7.3) MSI-16-V MSI-16-H Model Wise Description: Sr. No Model Description (XX = No. of channel ) 7.2 MSI-16C-XX 7.3 MSI-16A-XX Microprocessor

More information

Rosemount 3900/3900VP

Rosemount 3900/3900VP Rosemount 3900/3900VP General Purpose ph/orp Sensor Instruction Manual LIQ-MAN-3900 Rev. G April 2017 hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures, and

More information

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology Data Sheet Brooks Model MT 3810 Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology GENERAL FEATURES Broad range of flow capacities 5% Full scale accuracy

More information

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O Features Assembly System integration kit for Advanced Diagnostics PCS integration via Diagnostic Manager or device DTM Simple automatic

More information

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154. SPECIFICATIONS Low Cost 316L Stainless Steel or Titanium 19mm Diameter Package 0-100mV Output Gage and Absolute Wide Compensated Temperature Range The 154BC is a 19mm small profile, media compatible, piezoresistive

More information

Analog Room Pressure Monitor RPC Series

Analog Room Pressure Monitor RPC Series Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the

More information

Declaration of conformity

Declaration of conformity File: ATEX Manoswitch DoC 2017-10-20 Rev: 2017-10-20 id: mk Declaration of conformity The products listed in Appendix B, meet the requirements for a simple apparatus given by the standards listed below.

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH MICROPROCESSOR-BASED SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.25% High Accuracy Indication User-Selectable

More information

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control. Détecteur de gaz OLCT80 Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Disponible en version déportée, ADF ou de SI

More information

SmartLine Pressure Transmitters Modular, Accurate and Robust for the Lowest Cost of Ownership

SmartLine Pressure Transmitters Modular, Accurate and Robust for the Lowest Cost of Ownership Field Products SmartLine Pressure Transmitters Modular, Accurate and Robust for the Lowest Cost of Ownership Honeywell Innovation and Expertise When faced with demanding fi eld instrument application requirements,

More information

Datasheet: K-22 LO Sensor

Datasheet: K-22 LO Sensor Datasheet: K-22 LO Sensor The K- 22 LO is a CO2 sensor module designed to be built- in into stationary ventilation equipment, such as window vent or duct exhaust actuators, serving as a linear transmitter

More information

OOH740-A9-Ex Multi-sensor fire detector

OOH740-A9-Ex Multi-sensor fire detector OOH740-A9-Ex Multi-sensor fire detector ASAtechnology TM For potentially explosive areas Cerberus PRO Collective Signal processing with ASAtechnology Multiple protocol detector (collective/c-net-ex) Event-controlled

More information

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL P3359E 8th edition - November 2005 Simrad Optronics ASA Kabelgaten 4B P.O. Box 174, Økern NO-0509 OSLO, NORWAY Phone +47 22 66 60 00 Fax +47 22 66 60 01

More information

OOH740-A9-Ex Multisensor fire detector

OOH740-A9-Ex Multisensor fire detector OOH740-A9-Ex Multisensor fire detector ASAtechnology TM For potentially explosive areas Cerberus PRO Collective Signal processing with ASAtechnology Multiple protocol detector (collective/c-net-ex) Event-controlled

More information

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 505 Grünberg Tel.: 060 807-0 Fax: 060 807-59 A-ISOMETER IRDH575 Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with

More information

Enraf Servo Gauge 854 ATG

Enraf Servo Gauge 854 ATG Enraf Servo Gauge 854 ATG Setting the standard in gauging. From the company that pioneered development of modern tank gauges, Honeywell s 854 Automatic Tank Gauge has become an industry standard all over

More information

IntelliPack : 800 Series

IntelliPack : 800 Series 800 Series Models by Function Guide 800T Intelligent Transmitters 800A Intelligent Alarms 890M Math/Computation IntelliPack transmitter units convert sensor inputs to isolated process current or voltage

More information

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated SPECIFICATIONS 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature The 85 compensated is a small profile, media compatible, piezoresistive silicon pressure sensor packaged

More information

FAST RESPONSE TEMPERATURE SENSORS 42.11a

FAST RESPONSE TEMPERATURE SENSORS 42.11a FAST RESPONSE TEMPERATURE SENSORS 42.11a DESCRIPTION AND APPLICATION These resistance-type sensors are intended for contact temperature measurements of liquid and gaseous substances. The sensor consists

More information

Dual-point heat-tracing control system

Dual-point heat-tracing control system Dual-point heat-tracing control system 920*E4FWL*SIS302*SS3102 shown Product overview The Raychem 920 is a compact, full-featured, microprocessor-based, dual-point heat-tracing control system. The 920

More information

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Manual Change No Yokogawa Electric Corporation

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Manual Change No Yokogawa Electric Corporation User s Manual EJA Series Differential Pressure and Pressure Transmitters Manual Change No. 12-004 For the models EJA and EJA-A series with option code /KF21, /KU21, /KU22 or /KN26, please use this manual

More information

AND INSTALLATION MANUAL

AND INSTALLATION MANUAL Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel. +358 29 006 260 Fax +358 29 006 1260 Internet: www.labkotec.fi 10.10.2013 SET/DM3AL Level sensor OPERATION AND INSTALLATION MANUAL 1(5) SYMBOLS

More information

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Installation Manual. 1. Introduction. 2. Handling Cautions. 3.

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Installation Manual. 1. Introduction. 2. Handling Cautions. 3. User s Manual EJA Series Differential Pressure and Pressure Transmitters Installation Manual 1. Introduction 1.1 For Safe Use of Product...2 1.2 Warranty...3 1.3 ATEX Documentation...4 2. Handling Cautions

More information

SIL2-Interface/ -Signal Conditioners Series DuoTec

SIL2-Interface/ -Signal Conditioners Series DuoTec SIL2-Interface/ -Signal Conditioners Series DuoTec Certified according IEC 61508/ 61511 SIL2 DIN-Rail- and 19 -Mounting Since 1970 - Mütec Instruments GmbH Introduction To achieve a maximum safety in production

More information

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING POSITIONERS ELECTRO-PNEUMATIC INTELLIGENCE CONTROLS SERIES 6A FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS CELEBRATING The High Performance Company Y E A R S INTELLIGENCE Series 6A Intelligent Electro-Pneumatic

More information

TEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a

TEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a TEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a DESCRIPTION AND APPLICATION These resistance-type sensors are intended for contact temperature measurement of gaseous substances. The sensor consists of a metal

More information

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and vapors Dräger Polytron 8100 EC Detection of toxic gases and vapors The Polytron 8100 EC is Dräger s top of the line explosion proof transmitter for the detection of toxic gases or oxygen It uses a high performance

More information

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8100 EC Detection of toxic gases and oxygen Dräger Polytron 8100 EC Detection of toxic gases and oxygen The Polytron 8100 EC is Dräger s top of the line explosion-proof transmitter for the detection of toxic gases or oxygen It uses a high performance

More information

Product Information to the manual

Product Information to the manual Product Information to the manual Distributed I/O device ET 200iS, Version 10/2001 Introduction This product information contains fixes and additional information relevant to the user manual Distributed

More information

RS485 MODBUS Module 8AI

RS485 MODBUS Module 8AI Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information