1 Cronos Instruction manual (Rev11- Dec 2011; Firm. vers.4) WARNING! The user of this instrument must be trained to the use of power lasers and associated risks. LaserPoint is in no way liable for any damage resulting from improper, careless or above rated limits use of this instrument. LaserPoint srl - Via Burona, Vimodrone (Milano) - Italy Phone Telefax LaserPoint s.r.l. Cronos Instruction Manual All Rights are Reserved 1

2 Declaration of Conformity Application of Council Directive(s): 89/336/EEC The EMC Directive Manufacturer s Name: LaserPoint s.r.l. Manufacturer s Address: Via Burona 51, Vimodrone (MI) - Italia Type of Equipment: Laser Power / Energy Meter Model No: CRONOS Years of test & manufacture: 2014 Standard(s) to which Conformity is Declared: EN :1992 Emission generic standard - Part 1: Residential, commercial and light industrial EN :1995 Immunity generic standard - Part 1: Industrial Standard Description Performance Criteria EN 55022:1994 Limits and methods of measurement of Class B amendment 1: 1995 radio interference characteristics of amendment 2: 1997 information technology equipment EN :1995 Electromagnetic compatibility (EMC) Class B Part 4: Testing and measurements techniques- Section 4.2: Electrostatic discharge. I the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s). Place: Vimodrone - Italia Date: Dr. Luigi Argenti (Technical Director) LaserPoint s.r.l. Cronos Instruction Manual All Rights are Reserved 2

3 Calibration Model Reference Power (1064nm) Reference Power (10600nm) CRONOS LP W W Serial Number: Measured Power: Measured Power: W W Date of calibration: 1) In Models LP10 and LP5.0 measured values at wavelengths of CO 2 and Yag are the same, within the specified measurement accuracy. LaserPoint certifies that, at the time of calibration, the above listed instrument meets or exceeds all technical specifications defined at page 8 of this Instruction Manual. The above listed instrument has been calibrated using standard references traceable to the National Institute of Standards and Technology (NIST) or Physikalisch Technische Bundesanstalt (PTB). This is not a Calibration Certificate for traceability purpose; such a Calibration Certificate can be quoted on demand. Important - For Customer Use Only The reference setting of this instrument can be matched by user to a custom own reference by means of the instructions reported at Paragraph n.11 of the Operation Section of this Manual. LaserPoint s.r.l. Cronos Instruction Manual All Rights are Reserved 3

4 Operation Section 1-Safety Take all the required safety procedures needed when working with power laser beams and wear protection glasses all the time! The laser beam must hit ONLY the sensor head front side. Avoid to incidentally expose the protected stainless steel stem to the laser beam as dangerous back-reflections can be produced! Never touch the sensor head as this part can reach 70 C of temperature! In the case the laser power density is close to the damage threshold of the head absorber coating, damages like coating discoloration or underlying beginning of metal melting could occur. In both cases consult LaserPoint 2-Starting the Instrument To switch on the instrument, keep the ON/Zero button pushed until the LCD shows the serial number and the model of your instrument (LP.X, where X = 1.5, 5.0 or 10), then release it (this step takes approximately 2 seconds). The instrument will also display the selected laser wavelength; two options are possible: CO 2 (10.6 m) or YAG (1060nm). The wavelength displayed the first time is random; to change it refer to Paragraph 10 of this section. 3- Auto-check Cycle When the ON/Zero button is released, the instrument starts an auto-check cycle during which both circuit and display are controlled and reset. During this cycle, the LCD shows all available segments of alphanumeric characters and the bar graph at full scale. Upon completion of this cycle, the LCD displays the last recorded value of measured power.. 4-Zeroing/Resetting Before starting the first measurement or a new one, the instrument needs to be zeroed; to do so, just push and soon release the ON/Zero button. The LCD displays CAL and the LED on the right side of the LCS, turns steady green for approximately 5 seconds. At this point, any previously recorded value is zeroed and the instrument is ready to measure. LaserPoint s.r.l. Cronos Instruction Manual All Rights are Reserved 4

5 5-Measurement Cycle Check the laser shutter is closed and the laser is on; align the probe to the laser beam path and start the measurement cycle by opening the laser shutter. The measurement starts automatically and the measurement time is shown by a count down displayed on the LCD starting by Run 8 down to Run 0. This step takes approximately 8 seconds. During the acquisition time the LED blinks green. The bar graph indicates the head temperature on an arbitrary scale. Avoid measurements while the laser is warming up or when it shows instabilities on a few seconds period, as they can be meaningless or misreading. Always keep the instrument steady and the beam well centred, in particular on conical probes; do not move it during the readings to avoid measurement errors. 6-Measurement Display As soon as the measurement is over the LED turns into steady red. Remove the probe from the laser beam: the display shows the actual power, and the remaining thermal capacity. If the bar graph is below full scale, one or more measurements can be carried out before the sensor head needs to be cooled. The following measurement can be executed after the LED automatic shuts off and this takes between 10 and 20 sec depending on probe model. To perform a new measurement go back to Paragraph 4. 7-Cooling the Head Should the probe reach its limit temperature, the LCD shows COOL and the LED blinks red. Put the absorber head (only the head!) into water to cool it down. When the temperature falls below its maximum allowable limit, the LCD displays the last measured value and when the bar graph shows few bars, accurately dry the absorber by dry and clean air; the probe is ready for new measurements. 8-Auto Off /Battery Warning As the battery pack is about getting exhausted, a battery symbol pops up on the LCD: it warns you have approx. 10 hours of residual power. LaserPoint s.r.l. Cronos Instruction Manual All Rights are Reserved 5

6 Note: to increase the battery life, the instrument automatically switches off after 5 minutes of stand by operation. However the last recorded value is not lost; to retrieve it, go back to Paragraph 2 and follow the instructions. After the internal auto check cycle, the display will show the last measured value. To intentionally shut the instrument off, keep the ON/Zero button pushed until the LCD shuts off (this takes approximately 4 seconds). 9-Out of Range Notice When the head is exposed to a source exceeding its full scale, the LCD shows ERR instead of a numeric value. 10-Wavelength Selection To select the wavelength of operation (from CO2 to YAG or viceversa), go back to Paragraph 2 (shut the instrument off), but keep the ON/Zero button pushed until the wavelength change appears on the display (this step takes approximately 7 seconds). At this point release the button and the instrument is ready for a new measurement.. The displayed value is the last recorded power measurement carried out at this wavelength setting. 11-Customer s calibration This instrument can be re-calibrated by the user to match a custom reference. Remove the plastic cover of the adjustment switch located at the right side of the instrument body. Zero the instrument as indicated in Paragraph 2 of this Operation Section and afterwards carry out a measurement of a known laser source. Shift the switch on + or if you need to increase or decrease the reading displayed on the LCD to match your reference. This is done by limited pushes on the ON/Zero key, until the desired power value is achieved on the display. Reset the switch to its middle position CAL and re-cap. The instrument is ready for new measurements. LaserPoint s.r.l. Cronos Instruction Manual All Rights are Reserved 6

7 Notice to European Union Customers: European Union Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC The European Parliament will enforce new Directives in 2006 concerning the disposal of electrical and electronic equipment such as the Monitoring and Control Instruments. The regulations place responsibilities on the instruments supplier and the purchaser/user. One of the actions required by suppliers is to inform users of their obligations. The present instrument has been assessed in accordance with the European Parliament Directive2002/96/EC on Waste Electrical and Electronic Equipment, usually referred to as the WEEE Directive. The WEEE Directive requires that the instrument is disposed of at the end of its useful life in an environmentally responsible manner. Parts and materials that can be re-used and/or re-cycled have been identified in order that the use of new resources and the amount of waste going for landfill can be minimised. The WEEE Directive requires that if you are replacing the instrument with a new equivalent product from the original supplier, then that supplier can collect the old item without cost to yourself. It is emphasised that this no-cost return option is only available when you purchase a new product of equivalent type that fulfils the same function. Please inform your supplier of your wish to have the old instrument collected when ordering the replacement. If you wish to dispose of the instrument without replacing it then the appliance must not be mixed with unsorted municipal waste. The crossed-out wheeled bin symbol on the unit label or unit packaging, as shown in the table below, indicates this requirement. You must ensure that the instrument is disposed of at an authorised treatment facility; details can be obtained from your local council. Your rôle is critical and will help to ensure that the Earth s resources are maintained and that as much re-usable and re-cyclable material as possible is processed. It will also ensure that landfill volume requirements are kept at a minimum and that hazardous materials are not buried thereby providing potential future problems for the environment and human health. Wheeled bin symbol and description The symbol apply to all LaserPoint electronic products placed on the European Market after August 13, LaserPoint will affix the wheeled bin symbol with a bar to appropriate products. The bar indicates that the product was placed on the market after August 13, The WEEE Directive comes into force in January LaserPoint s.r.l. Cronos Instruction Manual All Rights are Reserved 7

8 Technical Specifications (*) : Parameter LP1.5 LP5.0 LP10 Maximum Measurable Power (W) Minimum Measurable ±4% Accuracy (W) (1) 150 (1) 500 (1) 1000 Absolute Minimum Measurable Power (W) Power density damage full scale at CO 2 wavelength (W/cm 2 ) Repeatability ±2% ±5% ±5% Measurement Accuracy ±4% Resolution (W) 1 Maximum allowable absorber temp. ( C) 150 Time to measure and display data at full scale power (s) 10 Time to measure and display data at min. scale power (s) 15 Power consumption in On status (mw) 26 Power consumption in Off status ( W) 25 Power supply (2x AA Batteries) (V) 3 Continuous operation without battery replacement (h) 200 Operating temperature range ( C) 10 to 40 Storage temperature range ( C) -10 to 60 Weight (g) Length with handle (mm) (*) Specifications subject to change without notice. (1) Individually compared against a NIST or PTB reference. Warranty All Laser Point instruments are warranted against defect in material and workmanship for one year after invoice date. During the warranty period Laser Point will repair, or at his sole option, replace at no charge components that prove to be defective, provided the parts are returned, shipping prepaid, to Laser Point Customer Service. This warranty does not apply if the instrument or any accessory has been damaged by accident or misuse, or as a result of service or modification by other body than Laser Point. No warranty is given by Laser Point on coatings and battery pack. LaserPoint s.r.l. Cronos Instruction Manual All Rights are Reserved 8

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear. SYNRAD, Inc. 4600 Campus Place Mukilteo, WA 98275 tel 1.425.349.3500 fax 1.425.349.3667 e-mail synrad@synrad.com web www.synrad.com Power Wizard PW-250 Operating Instructions Important Power Wizard power

More information

Customers must fill in and mail the warranty card in order to activate the warranty.

Customers must fill in and mail the warranty card in order to activate the warranty. WARRANTY The Gentec-EO UNO Single Channel Laser Power Meter comes with a one-year warranty (from date of shipment) against material and/or workmanship defects, when used under normal operating conditions.

More information

I/R Thermometer Gun 12:1

I/R Thermometer Gun 12:1 I/R Thermometer Gun 12:1 800103 INSTRUCTION MANUAL SPER SCIENTIFIC Contents Page 1. Introduction... 2 2. Safety Information... 3 3. Display And Button Locations... 4-5 4. Distance to Spot... 5 5. Measuring

More information

64 Max IR Thermometer

64 Max IR Thermometer 64 Max IR Thermometer Instructions PN 4861406 January 2017 2017 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective

More information

Dry Bath Heating Systems

Dry Bath Heating Systems Dry Bath Heating Systems Instruction Manual N2400-4001 Dry Bath Heating System, Single Block, Digital N2400-4002 Dry Bath Heating System, Dual Block, Digital www.starlabgroup.com DECLARATION OF CONFORMITY

More information

Operator's Manual. LIGHTNING 2 Laser Detector

Operator's Manual. LIGHTNING 2 Laser Detector Operator's Manual LIGHTNING 2 Laser Detector Thank you for purchasing an Apache Technologies, Inc. product. Your LIGHTNING 2 Laser Detector is a premium quality tool that has been designed and manufactured

More information

PL400 Patient Lift Scale Indicator Owner s Manual

PL400 Patient Lift Scale Indicator Owner s Manual PL400 Patient Lift Scale Indicator Owner s Manual CARDINAL SCALE MFG. CO. 8551-M912-01 Rev C PO BOX 151 WEBB CITY, MO 64870 Printed in USA 07/04 PH (417) 673-4631 - FAX (417) 673-5001 www.cardinalscale.com

More information

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS METEOROLOGICAL INSTRUMENTS INSTRUCTIONS MARINE WIND TRACKER MODEL 06206 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com

More information

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer User Manual Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer MODEL 42515 Introduction Congratulations on your purchase of the Model 42515 IR Thermometer. The Model 42515 IR thermometer

More information

Infrared Thermometer

Infrared Thermometer 572-2 Infrared Thermometer PN 4307046 March 2013, Rev. 1, 08/13 2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their

More information

User Manual. Humidity-Temperature Chart Recorder. Model RH520

User Manual. Humidity-Temperature Chart Recorder. Model RH520 User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,

More information

MODEL WIND TRACKER

MODEL WIND TRACKER MODEL 06201 WIND TRACKER NOVEMBER 2001 MANUAL PN: 06201-90 R. M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 MODEL 06201 WIND TRACKER

More information

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL Andover Corporation 4 Commercial Drive Salem, New Hampshire 03079-2800 Tel: (603) 893-6888 US Toll Free: (888) 893-9992 Fax: (603) 893-6508 Email:

More information

MODEL MARINE WIND TRACKER

MODEL MARINE WIND TRACKER MODEL 06206 MARINE WIND TRACKER NOVEMBER 2001 MANUAL PN 06206-90 R. M. YOUNG COMPANY 2801 AERO-PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, U. S. A. TEL: (231) 946-3980 FAX: (231) 946-4772 MODEL 06206 MARINE

More information

64 Max IR Thermometer

64 Max IR Thermometer 64 Max IR Thermometer Users Manual January 2017 2017 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.

More information

3R, 3G 5R, 5G Point Laser Levels

3R, 3G 5R, 5G Point Laser Levels 3R, 3G 5R, 5G Point Laser Levels Users Manual December 2018 (English) 2018 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks

More information

Dual Laser InfraRed (IR) Thermometer

Dual Laser InfraRed (IR) Thermometer User Manual Dual Laser InfraRed (IR) Thermometer MODEL 42512 Introduction Congratulations on your purchase of the Model 42512 IR Thermometer. This Infrared thermometer measures and displays non-contact

More information

Precision Infrared Thermometer. Users Manual

Precision Infrared Thermometer. Users Manual Precision Infrared Thermometer Users Manual March 2005 2005 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. LIMITED WARRANTY AND LIMITATION OF LIABILITY

More information

GMH 285 / GMH 285-BNC

GMH 285 / GMH 285-BNC GMH 285 GMH 285-BNC H69.0.01.6C-02 Operating Manual Pt1000 Precision Thermometer For exchangeable probes, with alarm as of version V1.0 GMH 285 / GMH 285-BNC GMH-GREISINGER GMH-GREISINGER WEEE-Reg.-Nr.

More information

62 MAX/62 MAX + Infrared Thermometer

62 MAX/62 MAX + Infrared Thermometer 62 MAX/62 MAX + Infrared Thermometer Users Manual PN 4060712 April 2012 Rev. 1, 11/12 2012 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice.

More information

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER Installation and Operation Manual MICROtrac Warranty Pulsafeeder, Inc. warrants MICROtrac control systems (including the conductivity sensor) of

More information

Thermo-/Hygrometer with Mould Alert Model WS 1500 Operating Manual

Thermo-/Hygrometer with Mould Alert Model WS 1500 Operating Manual Thermo-/Hygrometer with Mould Alert Model WS 1500 Operating Manual 1. Display & Settings Page 2 2. Features Page 3 3. Technical Data Page 3 4. Start-up Page 3 5. Important Information Page 5 6. Warranty

More information

On Electromagnetic Compatibility

On Electromagnetic Compatibility TECHNICAL REGULATION On Electromagnetic Compatibility Approved by Resolution of Cabinet of Ministers of Ukraine No. 785 dd. 2009.07.29 ELMAS LTD Index Index...2 General Provisions...3 Essential Requirements...5

More information

Model PT-05 Model PT-06

Model PT-05 Model PT-06 Model PT-05 Model PT-06 operators handbook Preface Dear User Welcome to the growing group of PT-06 Clam-Press and PT-05 Clam- Press Mini users. The product you have purchased has been carefully designed

More information

VS2000V Veterinary Vital Signs Monitor Operation Manual

VS2000V Veterinary Vital Signs Monitor Operation Manual VS2000V Veterinary Vital Signs Monitor Operation Manual - English Version 1.0, July 2011 2011 UTECH Co., Ltd. All rights reserved. Table of Contents Table of Contents Warranty and Service Information...

More information

Adam Equipment. NCSA 20plus. (P.N Revision B - September 2012)

Adam Equipment. NCSA 20plus. (P.N Revision B - September 2012) Adam Equipment NCSA 20plus (P.N. 7.00.6.6.0240 - Revision B - September 2012) Adam Equipment Company 2012 1.0 CONTENTS 1.0 CONTENTS...1 2.0 INTRODUCTION...2 2.1 FEATURES...2 2.2 TECHNICAL SPECIFICATIONS...2

More information

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide Miniature Thermoelectric Cooler Controller MTCC-01 user's guide 1 Table of Contents 1. Warranty... 3 2. MTCC-01-xxx overview... 4 2.1. MTCC-01-xxx specification... 4 2.2. TE cooled detector temperature

More information

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2 Version 1.6 Operating instructions HYDROETTE BL COPACT TF 2 EN 1 Table of contents 0.1 Publication statement... 3 0.2 General notes... 4 0.3 WEEE directive 2002/96/EC law on electrical and electronic equipment...

More information

Infrared Thermometer. Getting Started

Infrared Thermometer. Getting Started 572-2 Infrared Thermometer Getting Started PN 4307046 March 2013 2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their

More information

KM300 Carbon Monoxide Detection System Installation Manual

KM300 Carbon Monoxide Detection System Installation Manual GE Security KM300 Carbon Monoxide Detection System Installation Manual P/N 1068922 REV 2.0 16SEP09 Copyright Copyright 2009 GE Security, Inc. All rights reserved. This document may not be copied in whole

More information

Preamplifier Power Supply PPS-02 user's guide

Preamplifier Power Supply PPS-02 user's guide Preamplifier Power Supply PPS-02 user's guide 1 Table of contents 1. Warranty... 3 2. PPS-02 overview... 4 2.1. PPS-02 parameters... 4 2.2. Coding the symbol of the power supply...4 2.3. PPS-02 physical

More information

6R, 6G 180R, 180G. Users Manual. Point and Line Lasers. Line Laser Levels

6R, 6G 180R, 180G. Users Manual. Point and Line Lasers. Line Laser Levels 6R, 6G Point and Line Lasers 180R, 180G Line Laser Levels Users Manual December 2018 (English) 2018 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product

More information

SEC Signature Process Gas Analyzer

SEC Signature Process Gas Analyzer SEC Signature Process Gas Analyzer Instruction and Operation Manual Sensor Electronics Corporation 5500 Lincoln Drive Minneapolis, Minnesota 55436 USA (952) 938-9486 Fax (952) 938-9617 email sensor@minn.net

More information

Kinsa Smart Ear ThermometerTM Instructions For Use

Kinsa Smart Ear ThermometerTM Instructions For Use ENGLISH Kinsa Smart Ear ThermometerTM Instructions For Use Thank you for purchasing the Kinsa Smart Ear Thermometer, a professionally accurate instrument for fast and easy temperature taking in the ear.

More information

Model 1916-C/-R Hand-held Optical Power Meter

Model 1916-C/-R Hand-held Optical Power Meter Model 1916-C/-R Hand-held Optical Power Meter User s Manual 1 Warranty Newport Corporation warrants that this product will be free from defects in material and workmanship and will comply with Newport

More information

esense CO2 Transmitter and Alarm

esense CO2 Transmitter and Alarm esense CO2 Transmitter and Alarm Installation & Manual SE-0010, SE-0012, SE-0013, SE-0014 Rev. 22 November 2015 2015, CO2Meter.com. All Rights Reserved. Table of Contents General... 3 Opening the Housing...

More information

Wöhler CM 220. Carbon Monoxide Meter. The Measure of Technology. Contents. 1. Important information Specification... 13

Wöhler CM 220. Carbon Monoxide Meter. The Measure of Technology. Contents. 1. Important information Specification... 13 Carbon Monoxide Meter Contents 1. Important information... 12 2. Specification... 13 3. Operating Elements... 14 4. Operation Instructions... 15 5. 0-ppm-Calibration... 16 6. Troubleshooting... 17 7. CO

More information

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Operating Instructions Model: LD5 Dual Mode Refrigerant Gas Leak Detector PAGE

More information

User Manual. FieldMate Laser Power Meter

User Manual. FieldMate Laser Power Meter User Manual FieldMate Laser Power Meter User Manual FieldMate Laser Power Meter 27650 SW 95th Ave. Wilsonville, OR 97070 FieldMate User Manual This document is copyrighted with all rights reserved. Under

More information

Corning LSE Digital Dry Bath Heater

Corning LSE Digital Dry Bath Heater Corning LSE Digital Dry Bath Heater Instruction Manual Model Nos. 6875-SB, 6885-DB, 6895-FB 6876-SB, 6886-DB, 6896-FB 6877-SB, 6887-DB, 6897-FB 6878-SB, 6888-DB, 6898-FB About This Manual This manual is

More information

In accordance with the Radio Waves Act Chapter 58 Article 8(3), the document below is a

In accordance with the Radio Waves Act Chapter 58 Article 8(3), the document below is a Korea Communications Commission Notification 2011-37 In accordance with the Radio Waves Act Chapter 58 Article 8(3), the document below is a guideline for all broadcasting and telecommunications equipment

More information

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE Technical features Guide to LCD symbols Guide to keys Technical features Supply by communication bus Number of temperature levels 2 (DAY / NIGHT) Temperature

More information

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560 User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560 Introduction Congratulations on your purchase of the Model 42560 IR Thermometer. The Model 42560

More information

VISION H. Instruction manual

VISION H. Instruction manual VISION H Instruction manual EN Contents Introduction.. 3 Keyboard / Display... 4 1. Horizontal Operation.. 4 2. Tilt Function... 4 3. Power Supply of Laser.... 5 4. Detector............. 6 TE 6... 7 TE

More information

USER MANUAL AND TECHNICAL MANUAL

USER MANUAL AND TECHNICAL MANUAL USER MANUAL AND TECHNICAL MANUAL Kanmed Universal Warming Cabinets Kanmed Blanket Warming Cabinets Kanmed Combination Cabinet GE-2300-070 / 4 2014-05-12 NOTE: This manual contains important information

More information

Laser Safety Products. Edition 20

Laser Safety Products. Edition 20 Laser Safety Products Edition 20 Frequently Asked Questions How long will my glasses protect me? There is no simple answer to this question. Some glasses are worn-out after only one year, while others

More information

CALIBRATION HOW IT WORKS

CALIBRATION HOW IT WORKS HIGH POWER SOLUTIONS POWER DETECTORS ENERGY DETECTORS At Gentec-EO, we understand that the essence of our business since 40 years has been delivering accuracy. There are no half measures: it either measures

More information

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL Analox Sensor Technology Ltd 15 Ellerbeck Court Stokesley Business Park Stokesley TS9 5PT Tel: +44 (0)1642 711400 Fax: +44 (0)1642 713900 Email: info@analox.net

More information

Owner & Operator s Manual. Table of Contents

Owner & Operator s Manual. Table of Contents Owner & Operator s Manual Model No. Voltage Frequency 908041/9495160 100-120V 50 60 Hz 9495161 230V 50 60 Hz Table of Contents DESCRIPTION PAGE Safety 2 Technical Data 2 Unpacking Instructions 3 General

More information

MGC Dock User s Manual

MGC Dock User s Manual Operator s Manual Contents Warnings Statements/Avertisseement... 3 READ FIRST BEFORE OPERATION... 3 Basic Operation... 4 Clip Dock Components... 4 LEDs... 4 Operation... 5 Turning the Clip Dock On and

More information

High Temperature InfraRed Thermometer with Laser Pointer

High Temperature InfraRed Thermometer with Laser Pointer User s Manual High Temperature InfraRed Thermometer with Laser Pointer MODEL 42545A Introduction Congratulations on your purchase of the Model 42545A IR Thermometer. The 42545A is capable of non-contact

More information

MT4 MAX/MT4 MAX + Infrared Thermometer

MT4 MAX/MT4 MAX + Infrared Thermometer MT4 MAX/MT4 MAX + Infrared Thermometer Users Manual PN 4326561 August 2013 2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks

More information

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual Health Check Ear and Forehead Thermometer Model No.: 70125 Instruction Manual Thank you for choosing our Health Check Thermometer. This high-tech instrument measures body temperature via reflected infrared

More information

User Manual. FieldMate Laser Power Meter

User Manual. FieldMate Laser Power Meter User Manual FieldMate Laser Power Meter User Manual FieldMate Laser Power Meter 27650 SW 95th Ave. Wilsonville, OR 97070 FieldMate User Manual This document is copyrighted with all rights reserved. Under

More information

CALIBRATION HOW IT WORKS

CALIBRATION HOW IT WORKS HIGH POWER SOLUTIONS POWER DETECTORS ENERGY DETECTORS At Gentec-EO, we understand that the essence of our business since over 45 years has been delivering accuracy. There are no half measures: it either

More information

User's Guide. Pinless Moisture Meter. Model MO257

User's Guide. Pinless Moisture Meter. Model MO257 User's Guide Pinless Moisture Meter Model MO257 Introduction Congratulations on your purchase of the Extech MO257 Pinless Moisture Meter. The pinless moisture sensor monitors the moisture in wood and other

More information

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS METEOROLOGICAL INSTRUMENTS INSTRUCTIONS WIND TRACKER MODEL 06206 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com

More information

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV Instruction Manual Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV2 9296050000 About This Manual This manual is designed to assist you in optimal usage of your

More information

Software Version 2.01 LEVEL MONITOR MODEL 220

Software Version 2.01 LEVEL MONITOR MODEL 220 Software Version 2.01 LEVEL MONITOR MODEL 220 19 April 2000 CONTENTS 1. Introduction 1 1.1 Model Number Designation 2 1.2 Intrinsic Safety Considerations 3 2. Specification 4 3. Operation 6 3.1 Display

More information

KERN MPK Version GB

KERN MPK Version GB KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operation manual Personal scales KERN MPK Version

More information

Three Phase Prepayment Meter Liberty-3P

Three Phase Prepayment Meter Liberty-3P Three Phase Prepayment Meter Liberty-3P Consumer s Manual Safety Instructions Please take note of the warning and caution icons presented in this manual as follows: Possible Electric Hazard This icon indicates

More information

ANNEALING FURNACE MODEL 414 User Maintenance Manual/Handbook

ANNEALING FURNACE MODEL 414 User Maintenance Manual/Handbook ANNEALING FURNACE MODEL 414 User Maintenance Manual/Handbook Isothermal Technology Limited, Pine Grove, Southport, PR9 9AG, England Tel: +44 (0)1704 543830 Fax: +44 (0)1704 544799 Internet: www.isotech.co.uk

More information

100 Ft. LASER DISTANCE METER

100 Ft. LASER DISTANCE METER Model #050012 Component #692527 100 Ft. LASER DISTANCE METER THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, OPERATION, MAINTENANCE AND STORAGE OF THIS PRODUCT. BEFORE USE, READ CAREFULLY

More information

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295 User's Guide Pinless Moisture/Humidity Meter with Memory + IR Thermometer Model MO295 Introduction Congratulations on your purchase of the Extech MO295 Pinless Moisture Meter with Patented Built-in IR

More information

818E Series Energy Detector. User s Manual

818E Series Energy Detector. User s Manual 818E Series Energy Detector User s Manual 1 Warranty Newport Corporation warrants that this product will be free from defects in material and workmanship and will comply with Newport s published specifications

More information

OI-2400-DOCK Multi Gas Docking Station. Operation Manual trevision 2.2w

OI-2400-DOCK Multi Gas Docking Station. Operation Manual trevision 2.2w OI-2400-DOCK Multi Gas Docking Station Operation Manual trevision 2.2w Table of Contents Introduction... 3 Warnings Statements/Avertisseement... 4 Basic Operation... 5 OI-2400-DOCK Components... 5 LEDs...

More information

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR) Instruction Manual For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR) Corning Cat. No. 230V 230V Model No. Product Top Plate Size

More information

HIn3550 Magnetic Field Monitor User's Manual

HIn3550 Magnetic Field Monitor User's Manual HIn3550 Magnetic Field Monitor User's Manual Copyright 1993 by Holaday Industries, Inc. Manual #600053 10/97 $12.50 Revision Record Manual #600053 HIn3550 Magnetic Field Monitor Revision Description Date

More information

HXL. Operating instructions

HXL. Operating instructions HXL Operating instructions EN SCOPE OF DELIVERY FOR HXL: 1. HXL line laser 2. Battery adapter BA 3. AA batteries 4. Case 5. Magnetic holder MAH 6. Quick start guide 4 HXL 1. Laser beam output aperture

More information

Instruction manual EN

Instruction manual EN Instruction manual EN Contents Introduction... 3 Keyboard /Display... 4 1. Horizontal Operation... 5 2. Rotation Speed... 5 3. Slope in Manual Mode... 5 4. Mask Mode... 6 5. Setting the Levelling Precision

More information

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290 User's Guide Pinless Moisture/Humidity Meter + IR Model MO290 Introduction Congratulations on your purchase of the Extech MO290 Pinless Moisture Meter with Patented Built-in IR Thermometer. Monitor moisture

More information

USERS MANUAL FOR GAS BOILERS

USERS MANUAL FOR GAS BOILERS USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY: IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, INSTALLATION, USE AND MAINTENANCE OF THE APPLIANCE MODELS: NOVADENS 24 NOVADENS 24C NOVADENS

More information

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS CONTENTS 1. INTRODUCTION... 5 2. WARNINGS... 6 3. GENERAL DESCRIPTION... 7 4. INSTALLATION... 8 5. LUMINOUS INDICATORS AND COMMANDS... 9 6. DIP-SWITCH

More information

Mark 25 Ultrapure Water Conductivity Analyzer

Mark 25 Ultrapure Water Conductivity Analyzer Martek Instruments, Inc. Mark 25 Ultrapure Water Conductivity Analyzer Instruction Manual WARRANTY POLICY Unless otherwise stated, MARTEK INSTRUMENTS, INC. warrants this equipment to be free from defects

More information

VX SERIES Wireless Thermostat with Occupancy Sensor

VX SERIES Wireless Thermostat with Occupancy Sensor VX SERIES Wireless Thermostat with Occupancy Sensor INSTRUCTION MANUAL Table of Contents Thermostat Installation... 7 Installing the Wireless Control Card...8 Mounting the thermostat to the wall...9 Thermostat

More information

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power. PHOTO DETECTORS BEAM DIAGNOSTICS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER SOLUTIONS POWER DETECTORS ENERGY DETECTORS MONITORS PRESENTATION OVERVIEW OF THE DIFFERENT MODELS

More information

MicrOTDR. Optical Fault Locator. User Manual

MicrOTDR. Optical Fault Locator. User Manual Optical Fault Locator Datacom Textron 11001 31 st Place West Everett, WA 98204 TEL: 425-355-0590 Toll Free: 800-468-5557 FAX: 425-290-1600 Internet: www.datacom.textron.com Warranty The MicrOTDR Optical

More information

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK Analox 1000 Series User Manual Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK T: +44 (0)1642 711400 F: +44 (0)1642 713900 W: www.analox.net E: info@analox.net

More information

Digital Heat Block User Manual

Digital Heat Block User Manual Digital Heat Block User Manual Quidel Digital Heat Block Page 1 of 10 General Information Quidel Contact Information Contact Quidel Technical Support from 8:00 a.m. to 5:00 p.m. EST Tel: 800.874.1517 (in

More information

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions DT00 DT00-R DT0 DT0-R IFS Fiber Module Installation & Operation Instructions DR00 DR00-R DR00 DR00-R P/N 0 REV B ISS 0AUG DT00 CONTACT WHEN ON CHANNEL CONTACT TRANSMITTER ifs International Fiber Systems

More information

62 MAX/62 MAX + Infrared Thermometer. Users Manual

62 MAX/62 MAX + Infrared Thermometer. Users Manual 62 MAX/62 MAX + Infrared Thermometer Users Manual Introduction The Fluke 62 MAX and 62 MAX + Infrared Thermometers (the Product) can determine the surface temperature by measuring the amount of infrared

More information

R E N HI ITI CUSTOM AN LO +12v ADJUSTMENT

R E N HI ITI CUSTOM AN LO +12v ADJUSTMENT PAC-2000 REV D ELECTRIC COOLING FAN CONTOLLER PAC-2000 REV D FAN CONTROLLER SW1 FAN HIGH FAN LOW GND +12v SENDER A/C IGNITION SW2 CUSTOM ADJUSTMENT Choose option below GAUGE +12 V with key ON A/C clutch

More information

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com Model Infrared Food Thermometer FS-200 Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 3 Specifications... 4 Instrument Description... 5 Display Description... 5 Operating

More information

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00 OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00 Torrey Pines Scientific, Inc 2713 Loker Ave. West Carlsbad, CA 92010 Phone: 760-930-9400 Fax:

More information

Thermometer with Probe model 00891A

Thermometer with Probe model 00891A Instruction Manual Thermometer with Probe model 00891A CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Setup... 4 Temperature Units... 4 Placement

More information

Non-Touch Thermometer. User Manual. ARC Devices Ltd.

Non-Touch Thermometer. User Manual. ARC Devices Ltd. Non-Touch Thermometer User Manual ARC Devices Ltd. Copyright ARC Devices Ltd. 2016 Welcome to your new state of the art ARC InstaTemp digital infrared non-touch thermometer! The ARC InstaTemp is a digital

More information

Polar WearLink + Coded Transmitter 31 Coded Transmitter W.I.N.D. User Manual

Polar WearLink + Coded Transmitter 31 Coded Transmitter W.I.N.D. User Manual Polar WearLink + Coded Transmitter 31 Coded Transmitter W.I.N.D. User Manual A1 A2 B1 B2 B3 B4 C ENGLISH This user manual contains instructions for Polar WearLink 31 and Polar WearLink W.I.N.D. transmitters.

More information

Wireless Humidity/ Temperature Monitor Remote Wireless Sensor

Wireless Humidity/ Temperature Monitor Remote Wireless Sensor Wireless Humidity/ Temperature Monitor 800254 Remote Wireless Sensor 800255 Instruction Manual 1 TABLE OF CONTENTS Introduction...3 Features...4 Materials Supplied...4 Front Panel Description...5 LCD Display...7

More information

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power. BEAM DIAGNOSTICS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER SOLUTIONS POWER DETECTORS ENERGY DETECTORS MONITORS PRESENTATION OVERVIEW OF THE DIFFERENT MODELS Our photo detectors

More information

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

INSTALLATION GUIDE. AXIS A1001 Network Door Controller INSTALLATION GUIDE AXIS A1001 Network Door Controller Liability Every care has been taken in the preparation of this document. Please inform your local Axis office of any inaccuracies or omissions. Axis

More information

PROCESSING UNIT II V Hz V Hz. Table of Contents

PROCESSING UNIT II V Hz V Hz. Table of Contents PROCESSING UNIT II Owner & Operator s Manual Model No. Voltage Frequency 9494800 120V 50 60 Hz 9494801 230V 50 60 Hz Table of Contents DESCRIPTION PAGE Safety 2 Technical Data 3 Installation Instructions

More information

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland Electrical Safety Act (1135/2016) By decision of Parliament, the following is enacted:

More information

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1 Matrix2000 User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 s Version: 2.0 Revision: 1 IMPORTANT INFORMATION Limitation of liability It is mandatory, Matrix2000 panel to be installed in accordance

More information

safety & regulatory information

safety & regulatory information safety & regulatory information Document Part Number: 338610-001 Sixth Edition June 2006 This guide provides safety and regulatory information that is compliant with U.S., Canadian, and International regulations.

More information

KFP-CF Series Operation Manual

KFP-CF Series Operation Manual KFP-CF Series Operation Manual P/N 501-415103-2-31 REV 03.10 ISS 13NOV13 Copyright Trademarks and patents Manufacturer Version Certification European Union directives Contact information 2013 UTC Fire

More information

Important Safety Notice

Important Safety Notice Date: 27 th April 2015 Page 1 of 12 SPI Lasers UK Limited Safety Information High Power OEM Fibre Lasers Important Safety Notice This notice outlines important safety related information and must be read

More information

This instruction manual explains the use of three models listed on the left.

This instruction manual explains the use of three models listed on the left. Semiconductor Manufacturing Gas Detector This instruction manual explains the use of three models listed on the left. Keep this Instruction Manual available for quick reference when needed. Read this Instruction

More information

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions Important: Keep these User Instructions for reference 2 TABLE OF CONTENTS GENERAL SAFETY

More information

LogTag TICT - is0 Tag

LogTag TICT - is0 Tag TICT - is0 Tag Freeze Indicator with display DOCUMENT REVISION 1.0, 4 March 2014 Copyright 2014, LogTag Recorders Limited Contents Contents... 2 Document revision history... 2 Description... 3 Alerts...

More information

h is ngl E ASSISTANCE CENTRE AUTHORIZED RETAILER

h is ngl E ASSISTANCE CENTRE AUTHORIZED RETAILER Softcooker_03 Ed. 09/2015 Roner R FOREWORD - This manual was drawn up to provide the Customer with information concerning the machine and applicable standards, as well as instructions on operation and

More information