2 Intelligent lighting control and energy performance By designing intelligent lighting systems, lighting designers and engineers can achieve energy performance in a variety of building types. BY ROBERT J. GARRA JR., PE, CDT, CannonDesign, Grand Island, N.Y. Learning objectives Understand the codes and standards that dictate lighting design. Learn the steps to design and implement a smart lighting system. Realize the importance of control system commissioning. Lighting is typically one of the largest energy loads in any building, and historically it has been the hardest to control. People turn lights on and forget to turn them off. But technology has become more effective at combating this human weakness. The first revision of the simple on-off switch on the wall was the replacement of the switch with a dial or slider incandescent dimming switch, which saved electricity by allowing the user to select intermediate levels of illumination. Then, in the thick of the energy crisis of the late 1970s, the first occupancy sensors hit the market. No longer were humans the sole determinant of whether the lights were on or off now the machines also had a say. Stand-alone occupancy sensors and timer switches were connected to lighting fixtures, acting as a big brother and turning the lights off if no occupancy was sensed for a certain length of time, or when the time on the timer switch ran out. This innovation represented a tremendous improvement over the manual switch, bringing massive reductions in lighting loads. Next came network-based lighting controls, which controlled lighting zones by layering a time schedule over stand-alone controls and manual switches, turning off all the lights in the building at a certain time, overriding the switches and the stand-alone controls. The latest iteration, the advanced lighting control system, leverages the power of digitization and granularity. When properly implemented, these systems are user-friendly and easy to maintain, they provide the ability to effectively manage all of a building s lighting from a single centralized location, and they streamline physical maintenance and operation. Software-based lighting control also allows sharing of data not only between components of the lighting control system, but also with mechanical, fire safety, and security systems. This integration of smart systems enables effective management of all the building s energy consumers to realize energy reduction and cost savings. Despite the benefits, many engineers don t really understand advanced lighting control systems. This may be because the comprehensive nature of the system can seem complex and overwhelming, and engineers often just haven t taken the time to learn about it. The term advanced lighting control system may sound complicated, but what it really means is that you are merely layering communication interfaces over common hardware that engineers have traditionally used and are already quite familiar with ballasts, lamps, occupancy sensors, and other control devices or you are using a special type of this equipment. Often designers don t realize that familiarizing themselves with advanced lighting control systems can save them time and energy in the long run. The hardware is pretty much 56 Consulting-Specifying Engineer JANUARY/FEBRUARY

3 Six strategies give university a lighting edge The energy performance of Baltimore-based Coppin State University s Science and Technology Center, which is pending U.S. Green Building Council LEED Gold certification, is 20% below the baseline for an equivalent code-compliant lab building. One major factor in achieving this superior performance is the building s highly sophisticated lighting control system, using both time scheduling and occupancy control, plus four additional strategies: daylight harvesting, task tuning, personal control, and load shedding. Combined, these six strategies significantly reduce the building s electricity consumption and maximize efficiency. In most spaces, occupancy sensors signal the central lighting control system to switch lights off 30 minutes after a space is vacated. Unlike a typical occupancy sensor scheme, the system does not turn lights on only off. Occupants manually activate lighting in each lighting zone via a low-voltage switch. In the lab spaces, control is granulated to each lab module with adjustable light levels based on task or occupancy. This option allows faculty and students the most ideal light level for tasks without impacting others sharing the same area. To maximize daylight harvesting, the system automatically dims lighting when daylight is available, disallowing user override. To prevent overlighting, the system sets maximum lighting levels for particular tasks and uses in specific rooms. In individual workspaces, users are able to tailor lighting to their personal preferences, even in open offices. The system also helps modulate building-wide electrical loads by reducing light levels in certain areas at times of peak demand. This project was designed to exceed the energy code requirements of ASHRAE Standard Figure 1: The energy performance of Coppin State University s Science and Technology Center is 20% below the baseline for an equivalent code-compliant lab building. One major factor in achieving this superior performance is the building s highly sophisticated lighting control system, using both time scheduling and occupancy control, plus four additional strategies: daylight harvesting, task tuning, personal control, and load shedding. Combined, these six strategies significantly reduce the building s electricity consumption and maximize efficiency. This project was designed to exceed the energy code requirements of ASRHRAE Standard All graphics courtesy: CannonDesign Figure 2: To maximize daylight harvesting at Coppin State University s Science and Technology Center, the system automatically dims lighting when daylight is available, disallowing user override. To prevent overlighting, the system sets maximum lighting levels for particular tasks and uses in specific rooms. In individual workspaces, users are able to tailor lighting to their personal preferences, even in open offices. The system also helps modulate building-wide electrical loads by turning off lights in certain areas at times of peak demand. the same as it has been; the real change and advancement is the software systems. Updates to codes and standards Energy codes such as ASHRAE Standard 90.1, International Energy Conservation Code (IECC), and California Title 24 are becoming more stringent, and advanced lighting controls simply make it much easier to comply. With each new version, energy codes are trending toward the ultimate goal of net-zero energy consumption. Each of the codes is updated every 3 years, and the biggest changes are that the thresholds for triggering compliance are revised to encompass more projects. As an example, let s look at ASHRAE versus 2010 for some highlights: Threshold for compliance : Any new or retrofit projects encompassing 50% or greater alteration of the connected lighting load : Any new or retrofit projects encompassing 10% or greater alteration of the connected lighting load Automatic shutoff of lighting : Required in buildings greater than 5,000 sq ft : Required in all spaces Light level reduction : Not a requirement : Lighting must be wired to allow for a power reduction of 30% to 70%, in addition to turning off the lighting by either dimming or switching Daylight zones : Not a requirement : Daylighting control must be Consulting-Specifying Engineer JANUARY/FEBRUARY

4 Lighting controls automatic based on natural light contribution, and must be installed in spaces with windows and skylights n Exterior lighting : Lighting must be off during the day : Lighting must be off during the day, and lighting must be off or at a reduced level at night n Plug load control : Not a requirement : 50% of receptacles in private offices, open offices, and computer classrooms must be automatically shut off. Instead of looking at lighting control from a building level, many engineers still try to address each energy code requirement individually, installing multiple types of systems (e.g., relay control, architectural dimming systems, wall box dimming) in a single building without any central control. While this approach may satisfy the project s basic functional and energy code requirements, trying to fit a set of piecemeal systems together is really the harder way to go about things. Energy code requirements, rising energy costs, the importance of historical and up-to-the-minute building data collection and analysis, research on the effectiveness of controls, emerging technologies like easy-to-control LEDs, and demand for green buildings have driven manufacturers to develop systems that engineers can implement to meet these requirements. The thinking now is to make lighting controls as seamless as HVAC control provide the user comfort, but only use what you absolutely need. With the addition of the plug load control requirement, lighting control systems are quickly moving into the realm of energy management. System implementation There are essentially two types of advanced lighting control system implementation methods. The first is the use of digital addressable lighting interface (DALI) equipment. The address required for the system programming control is embedded in the ballast and control devices. The second is the use of addressable input/output modules that are layered over standard ballast and control devices. DALI-based systems seem to be proprietary in nature becauseyou are restricted to specific equipment. Some DALI-based system manufacturers require their devices be implemented Advanced lighting control systems allow you to employ all six of these strategies simultaneously. Without an advanced lighting control system, you are limited to the use of time scheduling, occupancy/vacancy control, and daylight harvesting. for proper operation. On the other hand, layered systems allow any device combination. But what really sets these systems apart is the software interface. Several manufacturers now use a graphical user interface (GUI) that allows the user to point and click to make programming changes to the system. Software also provides unprecedented energy management power, by enabling centralized management (with remote access); easy integration and data sharing with other building systems such as building automation systems (BAS), security systems, or fire alarm systems; and automatically generated maintenance alerts, device and system commissioning reports, and device usage reports. Armed with all of this data and computing power, building operators are empowered as never before to optimize energy consumption in their facilities. Advantages of advanced lighting control systems Advanced lighting control systems offer significant cost savings over conventional lighting controls. They provide additional granularity of control to ensure that all spaces, and even all luminaires, can be optimized around energy savings and visual performance. The control, and the finely detailed control and optimized energy savings, can be achieved by implementing six basic lighting control strategies: 1. Time/astronomical scheduling: Lighting in a defined area turns on or off, or dims, based on a predetermined, customizable schedule. 2. Occupancy/vacancy control: Lighting is turned on or off based on detected occupancy. With vacancy control, users must manually turn lights on, but lights are automatically turned off when a space is vacant. 3. Daylight harvesting: Electric light levels are automatically adjusted to account for the amount of natural sunlight in a space. Appropriate light levels are maintained for functional purposes, and total illumination is evenly maintained throughout the space. 4. Task tuning: Maximum light levels are set for a particular use or task in a specific room to prevent overlighting. 5. Personal control: Individuals can tailor the lighting in their workspace to their personal preferences, via a GUI on their computer. 6. Load shedding (or demand response): Lighting control can contribute to a building-wide effort to reduce demand. Lighting is turned off or dimmed in predetermined areas at times of peak demand. Advanced lighting control systems allow you to employ all six of these strategies simultaneously. Without an advanced lighting control system, you are limited to the use of time scheduling, occupancy/ vacancy control, and daylight harvesting. It is also important to note that you can t harness the full potential of daylight har- 58 Consulting-Specifying Engineer JANUARY/FEBRUARY

5 Lighting controls vesting with conventional controls. Conventional controls require one daylight sensor to control a group of lights, typically on one circuit or switch leg, which means that large groups of luminaires are controlled in the same manner. Centralized software control is required to implement task tuning, personal control, and load shedding (demand response). In addition to maximizing lighting efficiency, these systems increase occupant satisfaction and possibly even productivity. When occupants have control over their space, they tend to be happier and more productive. Easy-to-use control system software helps make required adjustments to keep up with dynamic changes. Best practices for design implementation Energy codes (ASHRAE 90.1, IECC, Title 24) basically define guidelines of best practices for the design implementation of an advanced lighting control system within the requirements. For example, for automatic daylighting control, ASHRAE 90.1 states that electric lighting shall be reduced with at least one control step that is between 50% and 70% of design lighting power and another control step that is no greater than 35% of power design. The following examples spell out best practices for implementing current energy code requirements. General requirements: n Start with a simple user-triggered lighting strategy. In each area of the building, occupants turn lights on via a low-voltage switch, and off by the same low-voltage switch. Electricity savings are maximized if users turn the lights on manually when they enter and remember to turn them off when they exit. If the user forgets to turn the lights off, automatic sensor coverage picks up the slack, signaling the central lighting control system to switch the lighting off in an area that is unoccupied or vacant, per energy code requirements. Vacancy sensors are generally considered more efficient than, and therefore preferable to, occupancy sensors, because they only turn lighting off, not on users have to turn lights on manually. In a private office with large windows letting in ample daylight, for example, the vacancy sensor ensures that the lights will only be turned on when occupants truly want or need them. n In addition to this simple lighting switching strategy, the advanced lighting control system automatically dims the lighting in areas that have Energy codes basically define guidelines of best practices for the design implementation of an advanced lighting control system within the requirements. adequate daylight penetration. As daylight levels change, the dimming levels of individual luminaires are adjusted so that the total illumination is evenly maintained throughout the space at the required level. n The advanced lighting control system controls emergency egress lighting. In the past, lighting on emergency circuits was often on 24/7 as a safety measure, burning through the night long after occupants of a building had left. Advances in control devices now allow emergency lighting circuits to be controlled by time schedules or by automatic sensors, and by equipping these devices with a UL 924 emergency transfer device that can override the digital lighting control system if normal power is lost, the system is able to turn on all lights connected to the emergency circuit and maintain egress levels for occupant safety without wasting energy when no one is around. n The advanced lighting control system is digitally connected to the BAS to use the detection signal of occupancy sensors at all hours to adjust mechanical setpoints. If multiple lighting control zones are provided in a single mechanical system zone, the lighting control system can accumulate the occupancy zones within the mechanical zone to help refine the efficiency of the HVAC system. Specific space requirements: n Interior private offices or rooms: Occupants turn lights on and off by pressing a low-voltage wall switch. A ceiling-mounted occupancy sensor operating in vacancy mode turns the room lighting off if occupants forget to turn it off when they leave. Personal control of these luminaires is made available on occupants computers. n Perimeter offices or rooms with adequate daylight: Occupants turn lights on and off by pressing a low-voltage wall switch. This switch turns the lights on to a level allowed by a photosensor that monitors the amount of daylight hitting the exterior of the window glass. A ceiling-mounted occupancy sensor operating in vacancy mode turns off the room lighting if occupants forget to turn it off when they leave. Personal control of these luminaires is made available on occupants computers. n Corridors and lobby: These are the only building areas with two modes of operation: during business hours and after business hours. In the corridors, an array of occupancy sensors turn lighting on and off according to occupancy and the current response mode, dictated by the advanced lighting control system s time clock. Perimeter areas are also equipped with photosensors to adjust the amount of electric light based on the amount of daylight in the space. Luminaires in these areas are adjusted to lower level output when a load shed signal is sent. n During business hours: Upon detecting occupancy in a corridor, the advanced lighting control system turns lights on and keeps them on until the system enters after business hours mode, after which point it only turns lights on when the building has occupancy, preventing the corridors from lighting up on holidays, snow days, and other low- 60 Consulting-Specifying Engineer JANUARY/FEBRUARY

6 Advanced lighting controls on California campus The Academic Core Buildings project at Ohlone College, Fremont, Calif., creates state-of-the art learning spaces and transforms the campus environment by revitalizing the campus main street, opening scenic views, and improving wayfinding and accessibility. An advanced lighting control system is implemented to help the campus achieve its aggressive energy conservation goals. The lighting control system complements the 2-MW photovoltaic (PV) array already installed on campus and the central utility plant s earth-coupled bidirectional cascade chiller system with heat-recovery chillers to generate chilled water and heating hot water. The earth-coupled system allows heat energy to be stored in the ground for later use. Waste heat is used to heat a large outdoor swimming pool. Figure 4: Ohlone s lighting control system design implements multiple strategies for optimized energy savings: Efficient daylight harvesting takes advantage of the abundant natural light from the exterior façade design. Automatic control, both vacancy and occupancy sensing, is used in most spaces. Time-based control scheduling is found in most common spaces, with additional setpoints to adjust the light level output when a load shed signal is sent. Task tuning is available in all classrooms, conference rooms, and shared spaces. Personal control is showcased in all office areas for user control and comfort. The lighting control system design implements multiple strategies for optimized energy savings: Efficient daylight harvesting takes advantage of the abundant natural light from the exterior façade design. Automatic control, both vacancy and occupancy sensing, is used in most spaces. Time-based control scheduling is found in most common spaces, with additional setpoints to adjust the light level output when a load shed signal is sent. Task tuning is available in all classrooms, conference rooms, and shared spaces. Personal control is showcased in all office areas for user control and comfort. This project was designed to exceed the energy code requirements of the California Title 24. Figure 3: An advanced lighting control system is implemented at Ohlone Community College District s Academic Core Building to help the campus achieve its aggressive energy conservation goals. The lighting control system complements the 2-MW photovoltaic (PV) array already installed on campus and the central utility plant s earth-coupled bidirectional cascade chiller system with heat-recovery chillers to generate chilled water and heating hot water. The earth-coupled system allows heat energy to be stored in the ground for later use. Waste heat is used to heat a large outdoor swimming pool. This project was designed to exceed the energy code requirements of the California Title 24. occupancy days. Lighting remains on in the corridor throughout the business day once triggered, preventing short on-off cycling of corridor lighting as occupants move from space to space. At the end of during business hours, the system transfers to the after business hours lighting control mode. After business hours: Occupancy sensors control corridor lighting via auto-on and auto-off functions. After 15 minutes of nondetection, lighting automatically turns off. Minimum cycling of lighting is expected during these lowoccupancy hours. Maximum light levels are set during this time period, as it is anticipated that the full light level will not be needed. Restrooms and stair towers: Lighting in these rooms is determined 24/7 by occupancy sensors. After 15 minutes of nondetection, the lighting automatically turns off. Luminaires in these areas are adjusted to lower level output when a load shed signal is sent. Utility and storage rooms: Occupants turn lights on and off by pressing a low-voltage switch on the wall. A 2-hour timeout sequence starts when the switch is activated. A blink warn occurs when five minutes remain in the 2-hour countdown. If the user wants to remain in the room, the switch can be activated again, and another 2-hour timeout sequence commences. Luminaires in these areas are adjusted to lower level output when a load shed signal is sent. It is worth noting that NFPA 70: National Electrical Code (NEC) Article (D), requires a manual switch/ override for electrical rooms. Consulting-Specifying Engineer JANUARY/FEBRUARY

7 Lighting controls n Conference rooms: Occupants turn the lights on and off by either pressing a low-voltage wall switch or utilizing a preset scene dimming control station. Ceiling-mounted occupancy sensors operating in vacancy mode turn the lighting off if occupants leave without turning off the lights. Maximum light levels are set for this space for certain tasks. Commissioning lighting controls Both ASHRAE 90.1 and IECC require commissioning of all control hardware and software to ensure that these elements perform as intended. The commissioning agent ascertains that the controls locations, adjustment, aiming, calibration, and programming all align with construction documents, field conditions, and manufacturer instructions. Commissioning of advanced lighting controls generally needs to be done outside of a space s normal work hours. The commissioning agent performs a number of procedures to test automatic sensors, photosensor and daylighting controls, time switches, and programmable schedule controls. Sensors are inspected to ensure that they are correctly placed and that their sensitivity and time-out adjustments deliver performance. Programmable schedule controls and time switches are checked to make sure they are set to turn the lights off as intended. Photosensor controls are inspected to ensure that their placement and sensitivity adjustments achieve the desired reduction in electric lighting based on available daylight. Commissioning of a daylight harvesting system often is required to occur at night so the true output of the electric system can be factored into the photosensor programming without any daylight contributions. The advanced lighting control system itself is also commissioned. The manufacturer of the system builds in testing procedures for individual components such as onboard fixture controllers to allow them to be checked when they are being installed. The system also takes stock of all components that are connected to it, allowing the commissioning agent to detect any unconnected or orphaned components. The commissioning agent also checks zoning, or the grouping of lights, and the system s programming, including control profiles, schedules, and load shedding sequences. Engineers and designers can aid the commissioning process by requesting the following items in the design specifications as part of the system submittal: programming intent narrative, a detailed bill of material, contractor checklist, and start-up request form. Common concerns One concern often voiced about advanced lighting control systems is that they are expensive. To operate an advanced lighting control system at the extreme of optimization, each light fix- NEW AP ARMAFLEX BLACK LAPSEAL INSULATION NEW Fast & Easy Wider release tab, quick installation Unique Lap seal closure, greater seam security New Sizes 3/8 to 6 ID 3/8 to 2 Wall INSTALL IT. TRUST IT. The easy-to-install, fiber-free, closed cell pipe insulation with a unique lap seal for greater seam security and increased protection against condensation, mold and energy loss. New angled cut and low profile lap seal deliver a superior bond that installs quicker than ever before Armacell LLC. Made in USA. input #24 at info.us@armacell.com

8 ture would be able to be individually controlled, and therefore equipped with a dimming ballast, or driver. Such a system would indeed be very expensive. But a few things have helped that type of system become competitive. First, LED technology is increasingly affordable, and it is being used more frequently. One advantage of LED lighting is that it is inherently dimmable: If you pair the LED s dimmable driver with a compatible control, additional components are not required to tune the light. The 20% to 30% adder for a controllable fluorescent ballast has disappeared, opening up the possibilities of light modularity as the norm instead of a novelty. Second, as engineers have learned how to leverage advanced lighting controls to manage energy usage, they have realized that significant savings in the system first cost could be achieved by thoughtfully grouping control of light fixtures into zoned areas, and not relying on individual light fixture control, which is rarely really necessary in typical building designs. Third, most advanced control systems use distributed low-voltage components instead of more traditional pipe and wire control strategies, so costs associated with a less rigorous installation method can often be reduced if a savvy contractor is brought on to implement the design. Another common concern is that advanced lighting control systems are difficult to manage. But this is generally a matter of perception. When you are dealing with a building that has more than 1,000 light fixtures, the thought of individually controlling each of them can seem overwhelming. But, as noted above, individual control isn t necessary, and careful planning can create a system that goes a long way to help facilities managers truly understand more about how their buildings really operate. Management of the entire building is done through web-based software. Anyone comfortable with using software on a PC will find this kind of system very straightforward to manage properly. Rising energy costs and more regulation through energy codes are making energy management a top priority for building owners and managers. The points noted above give designers and engineers additional tools to both meet and exceed the expectations of current and future energy code regulations. Robert J. Garra Jr. is vice president at CannonDesign. An engineering leader who understands clients and their goals, Garra applies his project leadership and industry knowledge across the firm s market segments, while providing strategic direction to the engineering group. He effectively manages integrated projects by encouraging multidisciplinary, highperformance design teams among CannonDesign, contractors, and clients. He is a Consulting-Specifying Engineer Under 40 award winner. Relays, Definite Purpose Contactors, Scroll Compressor Soft Starts and other products for HVAC OEMs The innovative SBWEB BACnet Controller reduces labor and wiring costs A wide variety of device level input and output devices for switches, lighting, etc For over 80 years, CARLO GAVAZZI has manufactured and marketed high quality automation components and systems. Gain a competitive edge by reducing your wiring and labor costs with our industry proven Dupline 2-wire bus system, which communicates directly to any BACnet controller via our innovative SBWEB Controller. CARLO GAVAZZI also offers a wide range of products for HVAC OEMs, such as definite purpose contactors, scroll compressor soft starts, electromechanical and solid state relays, etc. Please contact us today, as we look forward to hearing about your application. GavazziOnline.com Info@CarloGavazzi.com input #25 at

Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE

Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE Guides for California Title 24 & ASHRAE Code Compliance Lightcloud Makes Compliance Easy What are California Title 24 & ASHRAE? Links to Energy Codes Interior Lighting Controls Exterior Lighting Controls

More information

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015 Vive Solutions Commercial Application Guide Code Compliance Lighting Controls Table of Contents IECC IECC 2015 2015 Introduction Solutions Overview... 2 Summary of Code Requirements... 4 Daylight Zone

More information

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015 Vive Solutions Commercial Application Guide Code Compliance Lighting Controls Table Table of of Contents Contents Introduction Solutions Overview... 2 Summary of Code Requirements... 4 Daylight Zone Requirements...

More information

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2012

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2012 Vive Solutions Commercial Application Guide Code Compliance Lighting Controls Table of Contents IECC IECC 202 202 Introduction Solutions Overview... 2 Summary of Code Requirements... 4 Daylight Zone Requirements...

More information

Advanced Lighting Control for High Building Performance

Advanced Lighting Control for High Building Performance www.sylvania.com Advanced Lighting Control for High Building Performance Better Buildings by Design Kandice Castellino February 2014 Burlington, VT Why Advanced Lighting Controls? Controls Greater energy

More information

ANSI/ASHRAE/IES

ANSI/ASHRAE/IES Vive Solutions Commercial Application Guide Code Compliance Lighting Controls ANSI/ASHRAE/IES 90. 200 Table of Contents ASHRAE ASHRAE 90.-200 90.-200 Introduction Solutions Overview... 2 Summary of Code

More information

ANSI/ASHRAE/IES

ANSI/ASHRAE/IES Vive Solutions Commercial Application Guide Code Compliance Lighting Controls ANSI/ASHRAE/IES 90. 206 Table of Contents ASHRAE ASHRAE 90.-206 90.-206 Introduction Solutions Overview... 2 Summary of Code

More information

Reduce lighting energy costs with controls

Reduce lighting energy costs with controls Reduce lighting energy costs with controls Reduce energy costs. Support sustainability Get control of your lighting. Upgrading lighting systems to next-generation lighting technologies can deliver energy

More information

Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013

Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013 WHITE PAPER Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard 90.1-2010 & 2013 JUNE 2016 DT213 (Rev.10.2.17) Executive Summary ASHRAE Standard 90.1 is developed with the Illuminating Engineering

More information

Optimal control for superior lighting performance

Optimal control for superior lighting performance Optimal control for superior lighting performance Siemens Gamma provides lighting controls that maximize efficiency and energy savings. Answers for infrastructure. Integrated lighting controls that improve

More information

LightSweep. Lighting Control System

LightSweep. Lighting Control System LightSweep Lighting Control System Incredible Control GE LightSweep is a comprehensive indoor lighting control system designed to save money while improving the efficiency, comfort, safety and security

More information

Lighting Controls: The Next Big Thing in Lighting. June 18th, 2014

Lighting Controls: The Next Big Thing in Lighting. June 18th, 2014 Lighting Controls: The Next Big Thing in Lighting June 18th, 2014 Meet Your Panelists: Mike Carter Sr. Engineer, CEM Kandice Cohen New Business Development Manager Consumers Energy Subject Matter Experts:

More information

ASHRAE October 18, 2013

ASHRAE October 18, 2013 ASHRAE 90.1 2010 October 18, 2013 Energy Consumption Buildings consume 40% of the primary energy and 71% of the electrical energy in the US. Driven by economic expansion and population growth that require

More information

LIGHTING CONTROLS

LIGHTING CONTROLS 260923 LIGHTING CONTROLS PART 1: GENERAL 1.01 SUMMARY COMMENTS A. CU has developed this lighting control guideline to direct design professionals toward standard solutions that meet the University s performance

More information

Lighting Control Relay Panels Lighting Control Solutions

Lighting Control Relay Panels Lighting Control Solutions Lighting Control Relay Panels Lighting Control Solutions Make the most of your energy SM Lighting control relay panels from Schneider Electric will put you in control of your lighting, your comfort and

More information

WSA120: New Energy Codes and Lighting Controls

WSA120: New Energy Codes and Lighting Controls WSA120: New Energy Codes and Lighting Controls Member Since 2003 1.0 AIA/CES Learning Units (HSW) Partner Since 1998 Brought to you by WattStopper Today s Presenter: Joe McGrath www.wattstopper.com Learning

More information

TITLE 24 ICONOGRAPHY. Iconography System

TITLE 24 ICONOGRAPHY. Iconography System TITLE 24 ICONOGRAPHY Iconography System The icons symbolize specific language found in the code requirements. They represent product and space characteristics. Icons not only represent the requirements

More information

Advances in Lighting Controls and the Impact of ASHRAE Requirements. Rich Rattray, LC OSRAM SYLVANIA

Advances in Lighting Controls and the Impact of ASHRAE Requirements. Rich Rattray, LC OSRAM SYLVANIA Advances in Lighting Controls and the Impact of ASHRAE Requirements Rich Rattray, LC OSRAM SYLVANIA Click Addressable to edit Master Lighting title Controls style What are Addressable Lighting Controls?

More information

A Guide for Applicants and Lighting Designers

A Guide for Applicants and Lighting Designers Sustainable Office Design Program: A Guide for Applicants and Lighting Designers Inside this Guide: Introduction... 2 Organize Your Space... 3 Select Lighting Solutions... 4 Select Controls... 5 Open Offices...

More information

Design and Commissioning of Lighting Control Systems. Rick Miller, PE, LC, LEED AP RNM Engineering, Inc. October 18, 2012

Design and Commissioning of Lighting Control Systems. Rick Miller, PE, LC, LEED AP RNM Engineering, Inc. October 18, 2012 Design and Commissioning of Lighting Control Systems Rick Miller, PE, LC, LEED AP RNM Engineering, Inc. October 18, 2012 Objectives Review the Cx process as it relates to lighting control. Emphasize the

More information

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1) MANDATORY MEASURES INDOOR LIGHTING CONTROLS (Reference: Sub-Chapter 4, Section 130.1) MANDATORY LIGHTING CONTROLS 1. Area Controls: Manual controls that control lighting in each area separately 2. Multi-level

More information

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM DIVISION 26 ELECTRICAL SECTION 26 09 26 PART 1 GENERAL 1.01 DESCRIPTION A. The intent of this set of specifications is to provide a complete, functional, intelligent, lowvoltage lighting control system

More information

SECTION LIGHTING CONTROLS

SECTION LIGHTING CONTROLS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 09 23 LIGHTING CONTROLS SPEC WRITER NOTE: 1. Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable to

More information

Lighting Controls. Energy-Saving Solutions For Efficient Buildings

Lighting Controls. Energy-Saving Solutions For Efficient Buildings Lighting Controls Energy-Saving Solutions For Efficient Buildings Honeywell Lighting Controls Deliver Light When You Need It And Energy Savings When You Don t Businesses, schools and government facilities

More information

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification Dual Technology Wall Mounted Occupancy Sensor Manual & Specification PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES Douglas Lighting Controls Page 1 December 16, 2013 1. INTRODUCTION

More information

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1 Occupancy and Vacancy Sensors ENERLITES offers a wide variety of lighting sensors. They are designed to bring convenience to your life and business while helping to reduce energy consumption in commercial,

More information

Wireless Plug Load Control

Wireless Plug Load Control General Specification Wireless Plug Load Control Model No.: PL20R & PLBPC Description:Enerlites Wireless Plug Load Controller is designed with simplicity, and helps to make plug load control requirements

More information

Encelium Energy Management System Application and Design Guide

Encelium Energy Management System Application and Design Guide www.sylvania.com/encelium Encelium Energy Management System Application and Design Guide TABLE OF CONTENTS This brochure is designed as an introductory guide to the Energy Management System and how to

More information

Lighting Control Strategies. to meet code requirements save energy and improve building performance

Lighting Control Strategies. to meet code requirements save energy and improve building performance Lighting Control Strategies to meet code requirements save energy and improve building performance 1 Lighting Control Strategies Agenda Why Lighting Control Manual Light Reduction Scheduling Occupancy

More information

Wireless Indoor Lighting Control System

Wireless Indoor Lighting Control System enabled by Lutron Wireless Indoor Lighting Control System Lutron the image company TM enabled by Lutron simple to specify simple to install simple to use 2 AirLink Simple to specify The flexibility you

More information

Good-Better-Best LED Retrofit Guide

Good-Better-Best LED Retrofit Guide LED Retrofit Guide Presented by Michael Lane, LC Puget Sound Energy May 8th, 2018 1 LED Retrofit Guide The team was led by Michael Lane (PSE), facilitated by Debbie Driscoll (NEEA), and consisted of Shelley

More information

DALI Dimming Controls

DALI Dimming Controls DALI Dimming Controls ezdali Fluorescent dimming made simple and affordable A New Digital Revolution ezdali, Watt Stopper s new digital dimming and scene controls, uses the DALI communications protocol

More information

lighting control Simple and scalable Flexible control every step of the way DESIGN INSTALL MAINTAIN

lighting control Simple and scalable Flexible control every step of the way DESIGN INSTALL MAINTAIN Simple and scalable lighting control DESIGN INSTALL MAINTAIN Flexible control every step of the way Introducing a revolutionary wireless lighting control solution for new and existing commercial buildings.

More information

Dimming Ballast + Controls and CALCTP Bonus. New Product Overview

Dimming Ballast + Controls and CALCTP Bonus. New Product Overview 1 Dimming Ballast + Controls and CALCTP Bonus New Product Overview What are Dimming Ballasts + Basic Controls? Dimmable ballasts offer the potential to reduce energy consumption through smarter operation

More information

LIGHTING CONTROLS. Smart Enough to Work Right Out of the Box

LIGHTING CONTROLS. Smart Enough to Work Right Out of the Box LIGHTING CONTROLS Smart Enough to Work Right Out of the Box Welcome Installing efficient lighting and/or lighting controls are a couple of prime options building owners turn to in order to reduce energy

More information

Lighting Controls solutions for offices

Lighting Controls solutions for offices Lighting Controls solutions for offices Philips LightMaster maximizes comfort and minimizes energy with KNX. INTRODUCING THE PHILIPS LIGHTMASTER RANGE Adding expertise to industry standard solutions Philips

More information

High Performance Lighting. Terry Egnor Senior Consultant NBI

High Performance Lighting. Terry Egnor Senior Consultant NBI High Performance Lighting Terry Egnor Senior Consultant NBI Design Issues Energy Efficiency is not difficult Lighting Quality is not difficult Together, it is a challenge GOAL: Energy Effective Lighting

More information

CRESTRON: GREEN LIGHT NETWORK LIGHTING CONTROLS 1

CRESTRON: GREEN LIGHT NETWORK LIGHTING CONTROLS 1 GREEN LIGHT ARCHITECTURAL DIMMING CONTROLS (GLPD) Crestron Green Light and Green Light Express Network Dimming Control Systems are web accessible, network connected dimming control systems that receive

More information

Wireless Lighting Control Made Easy

Wireless Lighting Control Made Easy Wireless Lighting Control Made Easy Wireless Lighting Control Made Easy David Orband Crestron Electronics This session is eligible for 1 Contact Hour. For these hours to appear on your certificate, you

More information

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is. Energy Conservation Code Commercial Electric CHAPTER 5 WORKSHEET 1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is. a.

More information

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5 Sensor Buying Guide Table of Contents Sensor Models 2 Advantages of Sensors 3 FAQs 4-5 Occupancy and Vacancy Sensors, which provide automatic switching of lighting and motor loads, are fast becoming a

More information

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor TECHNICAL SPECIFICATIONS PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor Basic Features Line voltage version: 120-277VAC, 60Hz Low voltage version: 24VDC, requires separate class 2 power supply PIR sensor

More information

Lighting Application Guide for K-12 Classrooms

Lighting Application Guide for K-12 Classrooms Lighting Application Guide for K-12 Classrooms Lighting Controls for Today's Classroom Commercial building energy codes contain detailed mandatory lighting control requirements related to buildings such

More information

Advanced Lighting Solutions

Advanced Lighting Solutions Advanced Lighting Solutions Ben Koyle, LC, LEED Green Assoc. April 20, 2017 Learning Objective Gain a better understanding of the energy savings potential of LED luminaires and networked lighting control

More information

Applied Lighting Controls

Applied Lighting Controls Better Buildings By Design 2010 Applied Lighting Controls Steven Mesh, LC, IESNA Senior Lighting Program Coordinator Pacific Energy Center (Pacific Gas & Electric) 851 Howard Street, San Francisco, CA

More information

Empowering Your Vision

Empowering Your Vision Empowering Your Vision eldoled Empowering Your Vision At eldoled Light is Our Passion eldoled is the world leader in the design and manufacture of intelligent drive solutions for digital lighting systems.

More information

Fulham s Lighting Controls (LCS) Manage 7 Integrated Lighting Control Strategies

Fulham s Lighting Controls (LCS) Manage 7 Integrated Lighting Control Strategies Fulham s Lighting Controls (LCS) Manage 7 Integrated Lighting Control Strategies 1. DAYLIGHTING Daylighting employs sensors and lighting control systems to adjust lighting levels according to the availability

More information

Energy Codes. Connected Lighting simplified by Eaton. design and application guide

Energy Codes. Connected Lighting simplified by Eaton. design and application guide Codes Connected simplified by Eaton design and application guide We make connections work* Eaton Power Connectivity Apps * Simplif ied connected lighting solutions for Buildings, Communities & omes Eaton

More information

visual environment technologies etcconnect.com

visual environment technologies etcconnect.com visual environment technologies etcconnect.com About ETC ETC is a global leader in the manufacture of award-winning lighting-control systems, backed by our renowned /7/65 support. ETC offers complete solutions

More information

Mini Product Guide.

Mini Product Guide. Mini Product Guide www.acuitybrands.com/sensorswitch Better Performance Through Advanced Technology 100% Digital Passive Infrared (PIR) Detection Dual Technology Detection utilizing Microphonics Contractor

More information

Aesthetic, energyefficient. control solutions for hospitality facilities QUICK GUIDE TO LIGHTING CONTROL FOR HOTELS

Aesthetic, energyefficient. control solutions for hospitality facilities QUICK GUIDE TO LIGHTING CONTROL FOR HOTELS Aesthetic, energyefficient lighting control solutions for hospitality facilities QUICK GUIDE TO LIGHTING CONTROL FOR HOTELS Table of Contents Introduction 3 Guest room 4-5 Guest bathroom 6-7 Public areas

More information

California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings

California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings A Title 24 Code Review for Electrical Professionals By: Brian Friedel LEED AP brian.friedel@wattstopper.com

More information

Lighting Controls An Introduction and Review

Lighting Controls An Introduction and Review Lighting Controls An Introduction and Review Prepared by Dialectic Controls Beyond Timeclocks and Contactors When designing the lighting for a space, there is always a debate concerning what lighting control

More information

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and equipment. B. See Division 23 Section

More information

NOV Wireless Lighting Controls for. Parking Garage. Bright and Secure Lighting MAPS MAPS TM

NOV Wireless Lighting Controls for. Parking Garage. Bright and Secure Lighting MAPS MAPS TM NOV. 2017 MAPS Wireless Lighting Controls for Parking Garage Bright and Secure Lighting MAPS TM Bright and Secure Lighting Increase safety and security while lowering overall operating costs thanks to

More information

Maestro 0 10 V Dimmer Sensor

Maestro 0 10 V Dimmer Sensor NEW Maestro 0 10 V Dimmer Sensor Setting the new standard for 0 10 V control 0 10 V Dimmer Sinking control for 0 10 V fluorescent and LED fixtures Passive Infrared (PIR) Sensor Fine motion detection with

More information

SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1

SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1 SENSORS ENERLITES offers a wide variety of Occupancy and Vacancy sensor models that can monitor virtually any area within a building. We cover the spectrum of technologies with our passive infrared, basic

More information

Innovative. Integrated. Simple.

Innovative. Integrated. Simple. Innovative. Integrated. Simple. Energy Saving Lighting Controls Product Catalog VACANCY & OCCUPANCY SENSORS DAYLIGHTING CONTROLS LIGHTING CONTROL PANELS WIRELESS LIGHTING CONTROLS EMERGENCY LIGHTING CONTROLS

More information

COMcheck Software Version Interior Lighting Compliance Certificate

COMcheck Software Version Interior Lighting Compliance Certificate Section 1: Project Information Energy Code: 2009 IECC Project Type: New Construction COMcheck Software Version 4.0.2.8 Interior Lighting Compliance Certificate Construction Site: Owner/Agent: Designer/Contractor:

More information

Spaces are over lighted by 10-20% designed for worst-case interiors and fabrics, adjustable systems can tune-out waste

Spaces are over lighted by 10-20% designed for worst-case interiors and fabrics, adjustable systems can tune-out waste The Problem Occupants do not turn the lights off when they leave the space 11 Economics Office Space Energy Costs $1.50 to $2.50 ft2 Salary Costs over $200 ft2 Reducing energy costs by 50% saves $1.00

More information

A Simpler and Smarter Wireless Lighting Control Solution. Design & Application Guide

A Simpler and Smarter Wireless Lighting Control Solution. Design & Application Guide A Simpler and Smarter Wireless Lighting Control Solution Design & Application Guide Table of Contents 1. KNOWING THE OS-NET... 3 1.1 INTRODUCTION... 3 1.2 HOW DOES OS-NET WORK?... 3 1.3 OS-NET DEVICES...

More information

Built-in HF Sensor for High Bay

Built-in HF Sensor for High Bay Daylight Monitoring RX TM Synchronisation control Ambient daylight threshold Built-in HF Sensor for High Bay HC419VRC/R Tri-level Control With Synchronisation and Remote Control Applications Occupancy

More information

Welcome! AIA/CES Approved Seminar 1.0 LU/HSW. RAB8: Specifying a Networked Lighting Control System

Welcome! AIA/CES Approved Seminar 1.0 LU/HSW. RAB8: Specifying a Networked Lighting Control System Welcome! AIA/CES Approved Seminar 1.0 LU/HSW RAB8: Specifying a Networked Lighting Control System Jane Slade, MID, LC, LEED AP, IES Specification Sales Manager Updated July 2016 What has happened to our

More information

Code Compliance Commercial Application Guide

Code Compliance Commercial Application Guide Code Compliance Commercial Application Guide ASHRAE 90.1-2010 IECC 2012 Title 24-2013 Summary of code requirements for lighting control In the following pages, we ve provided examples of how Lutron solutions

More information

, ,

, , 796-2028, 796-2021, 796-2025 Batten mount PIR detectors Overview This series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide PIR/INT & PIR/INT-D Batten mount PIR detectors Overview The PIR/INT & PIR/INT-D miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional

More information

Shannon J Markey LC, LEED AP Legrand BCS / Wattstopper Western Regional Manager. Yesterday, Today & Tomorrow

Shannon J Markey LC, LEED AP Legrand BCS / Wattstopper Western Regional Manager. Yesterday, Today & Tomorrow Shannon J Markey LC, LEED AP Legrand BCS / Wattstopper Western Regional Manager Yesterday, Today & Tomorrow The Good Old Days: The.59 Cent Solution Simple, Inexpensive, Easy To Operate, Etc. Everybody

More information

ehub Application Note Boardrooms

ehub Application Note Boardrooms ehub Application Note Boardrooms Version 1 - October 2016 Application Note - Boardroom The modern boardroom is full of technology and an application where lighting control makes perfect sense. Controlling

More information

visual environment technologies etcconnect.com

visual environment technologies etcconnect.com visual environment technologies etcconnect.com About ETC ETC is a global leader in the manufacture of award-winning lighting-control systems, backed by our renowned /7/65 support. ETC offers complete solutions

More information

Isn t it about time somebody got controls under control?

Isn t it about time somebody got controls under control? Isn t it about time somebody got controls under control? Cree SmartCast Technology Wireless LED Lighting Controls Cree Cree Cree SmartCast Technology Simply all you need from your lighting. SPECIFIER Easy

More information

MANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately

MANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately MANDATORY MEASURES INDOOR LIGHTING CONTROLS (Reference: Sub-Chapter 4, Section 130.1) MANDATORY LIGHTING CONTROLS 1. 130.1 (a) Area Controls: Manual controls that control lighting in each area separately

More information

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification Dual Technology Wall Switch Occupancy Sensor Manual & Specification PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES Douglas Lighting Controls Page 1 November 19, 2014 1. INTRODUCTION

More information

East Central College

East Central College SECTION 260923 LIGHTING CONTROL DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Connected Buildings Sales positioning guide

Connected Buildings Sales positioning guide Connected Buildings Sales positioning guide * We make connected buildings work.* Make your workspace work for you. Eaton s connected lighting systems take the guesswork out of managing your facility, seamlessly

More information

Daylighting Control Design and Application Guide

Daylighting Control Design and Application Guide Daylighting Control Design and Application Guide DAYAPPS_1206 Design Guide Introduction Introduction Daylighting controls transform a day lit area into an energy-saving opportunity. The U.S. Environmental

More information

Green Building. Joshua Ong Assistance Sales Manager Schneider Electric (Singapore)

Green Building. Joshua Ong Assistance Sales Manager Schneider Electric (Singapore) Green Building Joshua Ong Assistance Sales Manager Schneider Electric (Singapore) 3 How can one achieve a green building? Source: NRDC Organisation, LEED Certification 4 Choose a sustainable site Maximize

More information

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 26 ELECTRICAL

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 26 ELECTRICAL 265100 INTERIOR LIGHTING PART 1 - GENERAL 1.1. Any deviation from the following instructions must be approved during design by WVU Facilities Management Personnel. 1.2. DEFINITIONS A. AHJ Authority Having

More information

Do More With Less

Do More With Less 1300 306 125 www.livezi.com.au Do More With Less Livezi have been the leaders in residential multizone full temperature systems since the mid nineteen nineties. Our 2012 product line-up represents the

More information

Lighting Control Solutions for Parking Facilities

Lighting Control Solutions for Parking Facilities Lighting Control Solutions for Parking Facilities Control Safety, Connect Strategies, and Commission Zones Parking Lighting Strategies for Optimal Performance Historically, parking garage lighting was

More information

FCSENS0R Occupancy Sensor. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

FCSENS0R Occupancy Sensor. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Description Long Description Product

More information

Product Specifications Dialog Room Controller* (*patent pending)

Product Specifications Dialog Room Controller* (*patent pending) 1 Product Specifications Dialog Room Controller* (*patent pending) 1. GENERAL 1.1. OVERVIEW 1.1.1. Provide a complete stand-alone, decentralized, low voltage, digital lighting control system for classrooms,

More information

Philips Lighting North America Corporation 200 Franklin Square Drive Somerset, NJ Tel

Philips Lighting North America Corporation 200 Franklin Square Drive Somerset, NJ Tel 2015 Koninklijke Philips N.V. All rights reserved. Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be

More information

SECTION DIGITAL-NETWORKING LIGHTING CONTROLS ENLIGHTED LIGHT MANAGEMENT SYSTEM

SECTION DIGITAL-NETWORKING LIGHTING CONTROLS ENLIGHTED LIGHT MANAGEMENT SYSTEM SECTION 260943.13 DIGITAL-NETWORKING LIGHTING CONTROLS ENLIGHTED LIGHT MANAGEMENT SYSTEM PART 1 - GENERAL 1.1 SUMMARY LED Lighting Upgrade 26 00 00 1 Digital Network Lighting Controls A. The following

More information

Excellence in LED Lighting. e-solis Edge Lit LED Panels.

Excellence in LED Lighting. e-solis Edge Lit LED Panels. Excellence in LED Lighting e-solis Edge Lit LED Panels www.axleninc.com A Revolution in Lighting Innovation e-solis A breakthrough in design innovation and the future of solid state lighting Industry-leading

More information

Inspection Phase Three. Mechanical, Electrical & Plumbing Section 503

Inspection Phase Three. Mechanical, Electrical & Plumbing Section 503 Inspection Phase Three Mechanical, Electrical & Plumbing Section 503 COMCheck Mechanical Field Inspection Checklist Mechanical Mechanical, Electrical & Plumbing Equipment Efficiencies But a lot ore too

More information

PoolPak MPK Series. PoolPak.com. Environmental Control Systems REDUCED FOOTPRINT & WEIGHT COMPARED TO EARLIER GENERATIONS

PoolPak MPK Series. PoolPak.com. Environmental Control Systems REDUCED FOOTPRINT & WEIGHT COMPARED TO EARLIER GENERATIONS PoolPak MPK Series Environmental Control Systems REDUCED FOOTPRINT & WEIGHT COMPARED TO EARLIER GENERATIONS PoolPak.com The PoolPak MPK Series Built using the PoolPak Proven Approach SM, the MPK Series

More information

Light is the solution ENCELIUM Energy Management System Light is OSRAM

Light is the solution ENCELIUM Energy Management System Light is OSRAM www.encelium.com Light is the solution ENCELIUM Energy Management System Light is OSRAM ENCELIUM Overview ENCELIUM Energy Management System More flexibility, more control, more energy savings Lighting

More information

1. Section [ Lighting Control Panel Boards:] Lighting panels (switching) controlled by ControlKeeper

1. Section [ Lighting Control Panel Boards:] Lighting panels (switching) controlled by ControlKeeper SECTION 260923 EATON DISTRIBUTED LOW-VOLTAGE POWER SYSTEM This specification was updated June 1, 2017 and supersedes all previous DLVP specifications. This section includes editing notes. These notes are

More information

Reducing Barriers to Use of High Efficiency Lighting Systems Oct. 2001

Reducing Barriers to Use of High Efficiency Lighting Systems Oct. 2001 2.10 Interview contractors and installers to determine installation and commissioning issues, such as times and costs, and to identify other possible technology, market and application barriers to use

More information

A new view on building protection. Cerberus DMS makes building protection smarter, easier and more flexible. Answers for infrastructure.

A new view on building protection. Cerberus DMS makes building protection smarter, easier and more flexible. Answers for infrastructure. A new view on building protection Cerberus DMS makes building protection smarter, easier and more flexible. Answers for infrastructure. Safety made easier. As an easy-to-use system with a single point

More information

The future of lighting management. Cutting costs and carbon keeping your building compliant.

The future of lighting management. Cutting costs and carbon keeping your building compliant. 3 The future of lighting management Cutting costs and carbon keeping your building compliant www.ridi.co.uk 3 Energy saving in an instant Rising energy costs are impossible to ignore and with a standard

More information

Advanced Lighting For Office

Advanced Lighting For Office Advanced Lighting For Office Open-Plan Office Applications High-Density 1 This High-Density 1 lighting application module presents alternative energy effective lighting design options for open-plan offices.

More information

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide EBMPIR-MB Batten mount PIR detectors Overview The EBMPIR-MB series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual

More information

Connected lighting components. Xitanium SR drivers EasyAir office sensors. Connected lighting components

Connected lighting components. Xitanium SR drivers EasyAir office sensors. Connected lighting components Connected lighting components Xitanium SR drivers EasyAir office sensors Connected lighting components The lighting infrastructure is all around us, making it perfect for collecting and carrying information.

More information

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is. 2018 NC Energy Conservation Code Commercial Electrical Module 5 CHAPTER 4 [CE] WORKSHEET 1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the

More information

Frequently asked questions: Intelligent Transmitter Series

Frequently asked questions: Intelligent Transmitter Series Frequently asked questions: Intelligent Transmitter Series The Wilcoxon family of Intelligent Transmitters, relay alarms, and communication modules can be used to implement low-cost online vibration monitoring

More information

Applications for correctional facilities. Greater efficiency and cost-effectiveness with GAMMA building control. Answers for infrastructure.

Applications for correctional facilities. Greater efficiency and cost-effectiveness with GAMMA building control. Answers for infrastructure. The world-wide standard for home and building control Applications for correctional facilities Greater efficiency and cost-effectiveness with GAMMA building control Answers for infrastructure. Successful

More information

Case Studies in Lighting Efficiency Honeycomb Intelligent Lighting Controls Kenneth Seeton

Case Studies in Lighting Efficiency Honeycomb Intelligent Lighting Controls Kenneth Seeton Case Studies in Lighting Efficiency Honeycomb Intelligent Lighting Controls Kenneth Seeton Wed, July 22, 2015 Project Scope and Savings Project location: NSM (Natural Science & Mathematics), ERC (Library)

More information

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR 5:1 FIRING RATE MODULATION LESS THAN 20 ppm NOx DIRECT VENT FLEXIBILITY TO 100 FEET 96% AFUE

More information

T-Series Climate Changer Air Handler. It s Hard To Stop A Trane.

T-Series Climate Changer Air Handler. It s Hard To Stop A Trane. T-Series Climate Changer Air Handler TM It s Hard To Stop A Trane. T-Series Climate Changer Air Handler The Trane tradition of excellence continues with the T-Series Climate Changer air handler. Using

More information