1 Dosimeters/Survey meters 40 Gracechurch Str., EC3V OBT, London, United Kingdom (24 Hour Customer Line)

2 RAD-ION (RI-02) Especially designed for the Detection of Pulsed (Golden Engineering) X-ray Energy The RAD- ION is the next generation ion chamber survey meter. This smart meter features accurate rate & dose measurements World class solution for use in nuclear Power plants, Nuclear medicine, Radiography, Life science, Research and other industrial applications. Provides highly stable and accurate measurement of dose rates and integrated dose of gamma, x- ray and beta radiation. Provides accurate readings as low as 60 nanosecond X- Ray bursts as emitted by pulsed X- ray Generators (Golden Engineering)

3 RAD-ION (RI-02) Features Large visible characters and numbers via LCD display 4 Touch pad buttons Beta slide window Icon identification differentiating between Gamma and Gamma Beta readings. Beta correction factor Automatic offset zeroing function Calibration mode Data storage Integrated Dose mode

4 Applications: Gamma and X- ray and Pulsed X- ray exposure survey meter with beta response Range: 0.00 usv/h to 1 Sv/h (0.00 mr/h to 100 R/h) Measuring: 1 usv/h to 1 Sv/h ( 0.1 mr/h to 100 R/h) Dose (D&M): Up to 10 Sv (1000 R) Energy Response: From 20 kev to 2 MeV Chamber Volume: 350 cm³ Side Wall: Plastic 300 mg/cm² ; Al 1000 mg/cm² available upon request Beta Shield: Retractable 1000 mg/cm² aluminum slide Window: 7 mg/cm² mylar/cloth material Window Area: 50 cm² (7.8 in²) Temperature Range: - 10 C to 50 C (23 F to 122 F) Display: multi- segments, liquid Crystal display with LED backlight Push buttons: 4 push buttons, simple operation Power: 2 each C cell batteries housed in a sealed externally accessible compartment

5 RAM-ION Especially designed for the Detection of Pulsed (Golden Engineering) X-ray Energy Battery operated, Auto ranging, Portable ion chamber Survey meter designed for highly stable and accurate measurements of dose rates and integrated dose of gamma, x- ray and beta radiation The auto ranging meter utilizes a combination display consisting of a smoothed digital readout for minimum fluctuation and a two decade analog bar graph for fast response Compact, hand- held, lightweight, rugged, easy to use and maintain

6 The RAM-ION Provides a straightforward, fast and reliable method of collecting and storing monitoring data on site for later use. Reads bar code labels that identify measurements location. The measurement's data combined with their locations, data and time are stored in a built- in memory. The stored data records can be downloaded by the SMARTS software packages. Ideal for use in nuclear power plants, nuclear medicine, radiography and radiotherapy facilities, life science laboratories, nuclear research centers and in other industrial applications

7 Ion chamber survey meter Highest safety: provides accurate readings as low as 60 nanosecond X- Ray bursts as emitted by pulsed X- ray Generators (Golden Engineering) Wide measuring range of 1µSv/hr to 500mSv/hr (0.1 mr/hr to 50 /hr) Built in memory to store data Dose rate and accumulated dose measurement Display illumination Freeze mode to record the highest dose User programmable dose rate and accumulated dose alarms Remote PC communication Hot Spot detection RAM-ION Main Features

8 RAM-ION Technical Data Measuring Range 1µSv/hr to 500mSv/hr (0.1 mr/hr to 50R/hr) Display Range 0.1µSv/hr to 500mSv/hr (0.01 mr/hr to 50R/hr) Accuracy ±10% of reading within measuring range Gamma Energy Dependence (137Cs) Better than ±20% at 20keV to 1.3MeV Angular Dependence (137Cs) Ion Chamber Volume Chamber Wall and Cover Thickness Window Thickness Response Time Less than ±5% (for ±120o of front direction 500 cc 300mg/cm2 (tissue equivalent) 7 mg/cm2 2 sec. for readings above 1 mr/h 5 sec. for auto- ranging change, from Low Range to High _Range (2sec. +3 additional seconds for auto ranging delay) Power Source (Built in automatic battery check) meter: two 1.5V C- type Alkaline cells hours of continuous operation laser scanner: One 9V Alkaline cell operations Display Data Logging Temperature Range DigiLog (3 digits and 2 decades of analog bar graph) 347 data records (1415 with extended memory) Operation - 10oC to +50oC (15oF - 122oF) Storage: - 20oC to +60oC (- 5oF - 140oF) Humidity Range Up to 95% RH (non condensing) Dimensions Width: 10cm (3.9"), length 25cm (9.8"), height 19cm (7.5") Weight 1100g (2.4lb) Casing High impact ABS

9 The DMC Personal Electronic Dosimeter The DMC 3000 covers a wide range of X- Ray and Gamma radiation detection fields from 15keV to 7Mev and linear response to dose rate fields from natural background up to more than 10 Sv/h. The pass- by data exchange feature gives unequal operational flexibility. In- motion reading allows dose management by sub- zone as well as real- time location tracking of personnel.

10 DMC 3000 Features Loud alarm, 85 db (A) typical, (> 90 db (C) peak) Vibrating alarm Highly visible backlit display Optional telemetry module Factory upgradeable firmware Simple 2- button navigation Extended dose rate alarms Dual ultra bright LED alarm Superior X- ray and gamma energy response Meets or exceeds applicable IEC and ANSI standards Designed with ruggedness and durability in mind

11 DMC Technical Specifications Radiological Characteristics Compliant with IEC 61526Ed. 3, ANSI Isotropy 241Am and 137Cs with ± 75 angle Measurement and display Energy response better than ± 20% (typically ± 10%) Accuracy Hp(10): ± 10%* (137Cs, ~ 24 msv/h); ± 15%*, (241Am, ~ 23 msv/h); ± 19%** X- ray 16keV (*including ± 5% extended uncertainty k=2); (** including ± 9% extended uncertainty k=2) Display dose: 1 µsv to 10 Sv (0.1 mrem to 1000 rem) Display rate: 10 µsv/h to 10 Sv/h (1 mrem/h to 1000 rem/h) or 1 µsv/h to 10Sv/h (0.1 mrem/h to 1000 rem/h) extended option. Dose Rate Linearity: < ± 20% up to 10 Sv/h (1000 rem/h) (Co and X H30 20 kev); < ± 20% up to 6 Sv/h (600 rem/h) (Pulsed X- rays 20 ms width, 1, 10 & 20 pps)

12 Electrical Characteristics Standard AAA (LR03) 1.5 V Alkaline battery 9 calendar month battery life (typical, 8 h per day, 5 days per week in run mode, without excessive alarms)* 2500 h battery life in continuous run, without excessive alarm Mechanical Characteristics DMC Technical Specifications Rugged, high impact polycarbonate- ABS case Dimensions: 86 x 56 x 21 mm (3.4 x 2.2 x 0.8 in) without clip Weight with alkaline battery and clip: < 88 g (3.1 oz) Worn by a replaceable clips (2 different style back clips or one a front- facing clip for DMC worn inside the pocket)

13 DMC Technical Specifications Environmental Characteristics Temperature range: - 10 C to 50 C (14 F to 122 F):deviation in response less than ± 5% Relative humidity: < 90% at 42 C (108 F) Storage: - 20 C to 71 C (- 4 F to 160 F) Shock, vibration and drop resistant (1.5 meter on concrete) Waterproof IP67: 1m (39 in) during 1 hour EMC: complies and exceeds standards by a large margin (Compliant, certificate number: 53720) MIL STD 461F RS103 (pulsed electric field): exceeds 200 V/m from 30 khz to 5GHz MIL STD 461F RS101 (magnetic field 30 Hz khz)

14 LDM USB Dosimeter Reader The LDM 320D and LDM 320W readers operate using software packages installed on computer (PC) and communicates with DMC 3000 dosimeter and DMC 2000 and SOR families in hands- free data exchange mode. The LDM 320 reader is used as an interface to activate a dosimeter (to switch into a counting mode) or to deactivate it (to switch into pause mode). When used by the included DMCUser software, it functions as an interface to read and write the internal data of the DMC 3000, SOR and DMC 2000 dosimeters

15 LDM USB Dosimeter Reader Compact and low- cost Hands- free communication with dosimeters No directional alignment required 3 Indicator LEDs for operation and access control Manageable digital inputs/outputs DSP based digital process Compatible with the DMC 2000 and SOR families, ipam- Tx as well as the DMC- 3000dosimeter Compatible with software packages: DOSICARE, DOSIFAST, DMCUser and LDM 3000SW Wall- mounted or desk versions

16 LDM-320 Technical Specifications Mechanical Characteristics: Length: 109 mm (4.3 in) Width: 100 mm (3.9 in) Depth: 29 mm (1.1 in) Weight: 150 gr (5.3 Oz) Environmental Characteristics: Operating temperature: 0 C to +50 C (32 F to 122 F) Storage temperature: - 10 C to +60 C (+14 F to 140 F) Humidity: 90% HR (without condensation) IP LDM 320D: IP52

17 PDS-GO Personal Radiation Detector Small, lightweight (125 g), sensitive, personal gamma radiation detector Meets ANSI N42.32 & requirements Designed using the latest state- of- the- art electronic components including the advanced technology of Silicon photomultiplier as a detector. Especially useful for professionals dealing in safety and security of sensitive installations, public areas and border control. Easily carried on the body and is used to detect the presence and magnitude of gamma emitting radiation.

18 PDS-GO Personal Radiation Detector CsI(Tl) scintillation crystal for high efficiency to extended energy range Excellent sensitivity to ANSI source strength Excellent temperature stability Two operation modes (Detect/Search) Low power consumption extended operating hours Instrument setup (alarm thresholds and other parameters) via USB connection to a PC using user- friendly software application. Record of event history Rechargeable battery charging via USB connection Accessories include protective silicon cover, belt clip, charging cradle, USB cable

19 PDS-GO Technical Specifications

20 RAM GENE-1 mark II Designed for work in extreme conditions Features a ruggedized casing, backlight and a specially designed energy filter embedded in the cap for dose rate radiation monitoring according to Ambient Dose Equivalent, with the additional flexibility of a contamination meter Equipped with a recessed, internal GM pancake detector using a thin mica window protected by a stainless steel screen The transition between measuring dose rate radiation and contamination is achieved by simply removing or placing the plastic cap

21 RAM GENE-1 mark II Features Large, four digit, continuous ranging, LCD display Simple, three key Features operation Large 1.75" pancake GM detector Suitable for alpha, beta or gamma contamination detection Unit readouts of count rate (CPS in contamination mode and µsv/hr in dose mode). Audible and visual (LED) count rate indication Smart software provides fast, yet stable response Dead time correction Alarms for overflow, low battery and detector failure Automatic self diagnostic routines Durable case with splash resistant keypad

22 RAM GENE-1 mark II Specifications Display: Large, four digit, continuous ranging LCD readout for display of count rate, dose rate, overflow, low battery, and detector failure. LED: Flashing count rate indication with Audio Piezo electric element synchronized with count LED. Units: Counts per second (CPS) or counts per minute (CPM) and µsv/hr or mr/hr. Controls: Three key keypad with positive feedback for ON/OFF Key combinations for selecting count rate or dose rate unit displays. Power: Standard 9V alkaline battery - provides approximately 50 hours continuous use with speaker off. Automatic battery check under full load. Detector: 1.75" Pancake GM tube - LND73118 or equivalent Window : Mica, mg/cm2 protected by stainless steel mesh. Count Range: 0-42,000 cps Sensitivity: Approximately 5.8 cps/µsv/hr (58 cps/mr/hr) - 137Cs Measuring Range: 0.05µSv/hr to 7mSv/hr (5µR/hr to 700mR/hr) Display Resolution: 0.01µSv/hr (0.001mR/hr) Background: 0-1 cps Temperature Range: Operation: - 10oC to +50oC (15oF to 122oF) Storage: - 20oC to +60oC (- 5oF to 140oF) Humidity Range: 40% to 95% RH (non condensing) Case: High impact ABS Dimensions: 11.4cm *7.2cm *6.7cm (4.5" x 2.8" x 2.6") (including Detector) Weight: 560 gram (1.23 lbs) (including battery)

23 RAM GAM-1 Gamma Survey Meter with state of the art microprocessor Compact, portable, lightweight designed for single- handed operation Offers optimal performance and is ideal for maintaining the highest safety standards in various applications

24 RAM GAM-1 Features Large, four digit, continuous ranging, LCD display Simple, three key operation Readout of dose rate and accumulated dose Units of either mr or µsv Programmable alarm thresholds Audible and visual (LED) count rate indication Smart software provides fast, yet stable response Dead time correction Alarms for detector overflow, low battery and detector failure Automatic self diagnostic routines Durable case with splash resistant keypad

25 RAM GAM-1 Specifications Display: LED: Audio: Units: Controls: Power Source: Detector: Measuring Range: Large, four digit, continuous ranging, LCD readout for display of accumulated dose, dose rate, alarm threshold value, overflow, low battery, and detector failure Flashing count rate indication Piezo electric element synchronised with count LED mr and mr/hr or µsv and µsv/hr Three key keypad with positive feedback for ON/OFF, RESET and SPEAKER. Key combinations for selecting accumulated dose and threshold displays Standard 9V alkaline battery - provides approximately 50 hours continuous use with speaker off. Automatic battery check under full load. Energy compensated GM tube - ZP1201 or equivalent 0.05mR/hr to 999mR/hr (0.5µSv/hr to 9999µSv/hr) Display Range: Sensitivity: Accuracy: Energy Range: Energy Dependence: Angular Dependence: 0.05mR/hr to 999mR/hr (0.5µSv/hr to 9999µSv/hr) 17 cps/mr/hr (137Cs) ±15% of reading within measuring range 50keV to 2.0 MeV ±20% related to 137Cs Less than ±20% for ±45o of preferred direction Temperature Range: Operation: -10oC to +50oC (15oF to 122oF) Storage: -20oC to +60oC (-5oF to 140oF) Humidity Range: 40% to 95% RH (non condensing) Case: High impact ABS Dimensions: 13cm x 7.2cm x 3.4cm (5.12" x 2.83" x 1.34") Weight: Kg (0.62 lbs)

26 DRM Data Radiation Monitor The DRM- 2 is a GM tube- based wide range Area Monitor designed specifically to be used as a fixed monitor in varying dose rate fields using two very sensitive, auto switching GM tubes. The DRM s detector features a linear response from 0.1µSv/h to 10Sv/h (10uR/h to 1000R/h). Wall- mounted instrument that can be connected to AC power with NiMH backup batteries. The radiation data is sent via 900 MHz FHSS or 2.4 GHz FHSS radios to a transceiver or via hardwire (RS- 232 or RS- 485) to a Remote Monitoring System. The DRM- 2 can also be connected directly to a computer input.

27 DRM Applications Perimeter or boundary surveillance The DRM is a portable or fixed position device used for perimeter and/or boundary monitoring used to quickly identify changing radiological conditions. Collection of radiological survey data for real- time mapping and surveillance software The DRM provides live radiological data for display, archiving and trending in real- time mapping software programs (e.g. TeleMap).

28 DRM Features Readout of dose rate and accumulated dose Ruggedized construction, metal casing User- selectable internal alarm threshold Built- in RS- 232/RS- 485 communication connection for use with Area Monitor or WRM transmitter. Output plug for Local Alarm Unit. Calibration software (optional) Dead time correction Alarms for detector overflow, low battery and detector failure Automatic self diagnostic routines RADNET and CE compatible

29 DRM Specifications Measuring Range: Sensitivity: Accuracy: Units: Power Source: Temperature Range : 0.1. µsv/hr to 10Sv/hr (10µR/hr -1000R/hr) 0.3cps/mR/hr (137 Cs) ±10 % of reading within measuring range µsv and µsv/hr or mr and mr/hr External AC Power backed up by two NiMH batteries Operation: -10oC to +50oC (15oF to 122oF) Storage: -20oC to +60oC (-5oF to 140oF) Humidity Range : Case: 40% to 95% RH (non condensing) Blue anodized aluminum Dimensions: 93mm W x 148mm L x 56mm H (3.7 " x 5.8 " x 2.2 ") Weight: Radio Frequencies: 680g (1.5 lbs) 900 MHz FHSS or 2.4 GHz FHSS

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009 RAM GENE-1 ERK MK-Ι & MK-ΙΙ Contamination & Radiation Meter Operating Manual Document #PRIR90N2.DOC Version 2.2 October 2009 Version / Revision Log: RAM GENE-1 ERK/ Operating Manual Ver./Rev.# Date Revised

More information

DMC 3000 User s Guide

DMC 3000 User s Guide Health Physics Division DMC 3000 User s Guide 151153EN-D Table of Contents -2-1- Presentation...3 2- General...4 2.1 Use and Functionality... 4 2.2 Compatibility with Mirion Technologies Products... 5

More information

RAM GENE / RAM GENE-1

RAM GENE / RAM GENE-1 RAM GENE / RAM GENE-1 Radiation Meters Operating Manual Document #PRIR69N0.DOC Version 6.1 - December 2000 ROTEM INDUSTRIES LTD. ROTEM Industrial Park P.O.Box 9046, Beer-Sheva 84190, ISRAEL Tel: 972-8-6571312/6568652

More information

DMC 3000 Quick User s Guide

DMC 3000 Quick User s Guide Health Physics Division Radiation. Safety. DMC 3000 Quick User s Guide Welcome to your DMC 3000! In approaching the opportunity to create a more refined Personal Electronic Dosimeter, we wanted to address

More information

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System FEATURES: HIGH GAMMA SENSITIVITY MULTI-CHANNEL ANALYZER (MCA) WORKS WITH VARIETY OF PROBES RADIONUCLIDE LIBRARY TAILORED TO CUSTOMER REQUEST SIMULTANEOUSLY MEASURES ; DISPLAYS; ALARMS 1-3 SEPARATE DETECTORS

More information

Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006

Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006 Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One Firmware Version 3.00 D August 2006 GammaRAE II Responder Features Getting Started Replacing the batteries Turn the unit

More information

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31 User s Manual Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30 Fuji Electric Co., Ltd. TN514629i 1/31 Introduction Thank you for purchasing the Electronic Personal Dosimeter NRF30 (Hereinafter described

More information

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017 MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER August 2017 MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER August 2017 ii STATEMENT OF WARRANTY Ludlum Measurements, Inc. warrants the products covered

More information

DMC 2000 Personal Electronic Dosimeter

DMC 2000 Personal Electronic Dosimeter DMC 2000 Personal Electronic Dosimeter Accurate Dose And Dose Rate Measurement Pre-Set Audible And Visual Alarms Small Lightweight Design PROTECTION BEGINS WITH DETECTION The fi rst step in providing hazard

More information

LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER S MANUAL. October 2014 Serial Number and Succeeding Serial Numbers

LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER S MANUAL. October 2014 Serial Number and Succeeding Serial Numbers LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER S MANUAL October 2014 Serial Number 25000100 and Succeeding Serial Numbers LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER S MANUAL October

More information

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection Level 3 Information Use NISP-RP-001 Industry Approval Date: September 14, 2018 This is an industry document for standardizing radiation protection

More information

Nuclear Associates

Nuclear Associates Nuclear Associates 05-575 MiniMonitor III Multipurpose X and Gamma Ray Survey Meter Operators Manual February 2005 Manual No. 05-575-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. Printed

More information

Portable Survey Instruments NISP-RP-01

Portable Survey Instruments NISP-RP-01 NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection NISP-RP-01 This is an industry document for standardizing radiation protection processes used by supplemental radiation protection technicians.

More information

Area Monitor/Frisker Count Rate Meter Victoreen

Area Monitor/Frisker Count Rate Meter Victoreen Area Monitor/Frisker Count Rate Meter Victoreen Model 190F! Adjustable Alarm! Backlit analog/digital display! Interchangeable probe adapter module! Multiple probe use! Redundant power supply! Available

More information

Contamination Meter Users Manual

Contamination Meter Users Manual RDS-80 Contamination Meter U Users Manual Version 1.01 LAURUS Systems, Inc. - Ph: 410-465-5558 - Fax: 410-465-5257 - www.laurussystems.com NOTE This document and the information herewith are copyrighted

More information

Our Extended Personal Electronic Dosimeter (PED) Family

Our Extended Personal Electronic Dosimeter (PED) Family Our Extended Personal Electronic Dosimeter (PED) Family Tracerco s Award Winning Radiation Monitors and Servicing business unit provides a range of products and services accredited to ISO9001:2008 and

More information

DIGITAL AREA RADIATION MONITOR

DIGITAL AREA RADIATION MONITOR RADIATION DETECTION AND MONITORS 103 AREAEXPERT DIGITAL AREA RADIATION MONITOR Touch screen LCD Colorful visual and audio indications Network compatible with CenterExpert software PC controllable Easily

More information

PRD Domestic Price List

PRD Domestic Price List 901 nukalert Keychain Upper Limit Radiation Detector $150.00 907 palmrad Alpha, Beta, Gamma and X Ray Meter w/ 3 second update $760.00 P/N 6941 palmgraph windows software for Model 907 $110.00 P/N 6947

More information

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL AM-806 Waste/Door Radiation Monitor OPERATIONS MANUAL Section Contents 1. SPECIFICATIONS 2. MAIN COMPONENTS 3. THEORY OF OPERATION 4. OPERATING INSTRUCTIONS 5. INSTALLATION Page 2 1.0 SPECIFICATIONS SENSITIVITY

More information

Radiation Alert Frisker INTERNATIONAL

Radiation Alert Frisker INTERNATIONAL Radiation Alert Frisker INTERNATIONAL S.E. International, Inc. P.O. Box 39, 436 Farm Rd. Summertown, TN 38483 USA 1.800.293.5759 931.964.3561 Fax: 1.931.964.3564 www.seintl.com radiationinfo@seintl.com

More information

RAD-60 USER GUIDE (ALSO FOR THE RAD-50 MODEL AND ISOTRAK DOSIMETERS)

RAD-60 USER GUIDE (ALSO FOR THE RAD-50 MODEL AND ISOTRAK DOSIMETERS) RAD-60 USER GUIDE (ALSO FOR THE RAD-50 MODEL AND ISOTRAK DOSIMETERS) 2 RAD-60 DOSIMETER USER S GUIDE The RAD-60 is a Digital Pocket Alarm Stand Alone Dosimeter designed for use by people who may be exposed

More information

LUDLUM MODEL 3276 SERIES FRISKER/AREA MONITOR USER S MANUAL. November 2017 Serial Number: and Succeeding Firmware: 49830n30 and Higher

LUDLUM MODEL 3276 SERIES FRISKER/AREA MONITOR USER S MANUAL. November 2017 Serial Number: and Succeeding Firmware: 49830n30 and Higher LUDLUM MODEL 3276 SERIES FRISKER/AREA MONITOR USER S MANUAL November 2017 Serial Number: 25009185 and Succeeding Firmware: 49830n30 and Higher LUDLUM MODEL 3276 SERIES FRISKER/AREA MONITOR USER S MANUAL

More information

910A DOSIMETER CHARGER, AC-POWERED

910A DOSIMETER CHARGER, AC-POWERED DOSMETERS, MONTORS & METERS DRECT READNG DOSMETER 909B DOSMETER CHARGER 343-750 ELECTRONC POCKET DOSMETER Model 23, mrem and Model 23-1, msv Range 343-490 Direct Reading Dosimeter 0-200 mr 343-495 Direct

More information

Identify the following features and specifications for the ESP1

Identify the following features and specifications for the ESP1 LEARNING OBJECTIVES: 2.17.01 List the factors which affect an RCT's selection of a portable contamination monitoring instrument, and identify appropriate instruments for contamination monitoring. (Also

More information

Using the GammaRAE II Personal Radiation Detector

Using the GammaRAE II Personal Radiation Detector Using the GammaRAE II Personal Radiation Detector GammaRAE II Features Normal Usage Turning Unit On Operating Mode User Screens Advanced Features Programming Mode Training Agenda GammaRAE II Features Detector:

More information

Kata products Kata DGM-1500 Turva

Kata products Kata DGM-1500 Turva Kata DGM-1500 Turva RADIATION DETECTED: Gamma and X-ray MEASUREMENT UNITS: microsv/h (μsv/h) LINEAR RANGE: Dose rate 0.01-100 000 microsv/h Dose 0.001-1000 millisv SENSITIVITY: 150 cpm/microsv/h ACCURACY:

More information

RAM GAM-1C Gamma Survey Meter TYPE TEST

RAM GAM-1C Gamma Survey Meter TYPE TEST Sunday, September 11, 2016 RAM GAM-1C Gamma Survey Meter TYPE TEST Compliance for ANSI N42.17A - 2003 American National Standard for Performance Specifications for Health Physics Instrumentation Portable

More information

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter NAKASHIMA, Sadao * MAEKAWA, Osamu * ABE, Shigeru * A B S T R A C T Conventional radiation exposure management methods included

More information

LUDLUM MODEL 26-1 FRISKER USER S MANUAL. April 2017 Serial Number PF and Succeeding Serial Numbers

LUDLUM MODEL 26-1 FRISKER USER S MANUAL. April 2017 Serial Number PF and Succeeding Serial Numbers LUDLUM MODEL 26-1 FRISKER USER S MANUAL April 2017 Serial Number PF002366 and Succeeding Serial Numbers LUDLUM MODEL 26-1 FRISKER USER S MANUAL April 2017 Serial Number PF002366 and Succeeding Serial Numbers

More information

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions. Personal Alpha/Beta Continuous Air Monitor (CAM) The pocamon (personal online continuous air monitor) monitors continuously the breathing air to detect airborne radioactive aerosols (LLRD). Typical application

More information

minidose A compact and colorful personal electronic dosimeter, your family can use everyday.

minidose A compact and colorful personal electronic dosimeter, your family can use everyday. minidose A compact and colorful personal electronic dosimeter, your family can use everyday. The minidose is an easy-to-use electronic personal dosimeter that records X-ray and/or Gamm radiation dose accumulated

More information

PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR

PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR _ PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR FEATURES: COMPLETELY PORTABLE OR WALL INSTALLATION CAN BE SET TO ANY WIDTH; QUICK SET UP VIDEO REAL-TIME DISPLAY & CAPTURE OPTIONAL: WIRELESS REMOTE NOTIFICATION

More information

Ranger EXP RADIATION A L E R T

Ranger EXP RADIATION A L E R T RADIATION A L E R T TM Ranger EXP INTERNATIONAL S.E. International, Inc. P.O. Box 39, 436 Farm Rd. Summertown, TN 38483 USA 1.800.293.5759 1.931.964.3561 Fax: 1.931.964.3564 www.seintl.com radiationinfo@seintl.com

More information

AERIAL RADIATION DETECTORS

AERIAL RADIATION DETECTORS DRONE READY AERIAL RADIATION DETECTORS DroneSENSOR TM Series Model ~ DroneRAD-ST TM (Search Tool or Mapping) - Gamma Model ~ DroneRAD-P TM (Air Monitor& Plume Detector) Particulate Alpha, Beta, Gamma &

More information

LUDLUM MODEL and PANCAKE CLUSTER DETECTORS. June 2016

LUDLUM MODEL and PANCAKE CLUSTER DETECTORS. June 2016 LUDLUM MODEL 44-89 and 44-94 PANCAKE CLUSTER DETECTORS June 2016 LUDLUM MODEL 44-89 and 44-94 PANCAKE CLUSTER DETECTORS June 2016 STATEMENT OF WARRANTY Ludlum Measurements, Inc. warrants the products covered

More information

LUDLUM MODEL AND LUDLUM MODEL ALPHA, BETA, & GAMMA DETECTORS

LUDLUM MODEL AND LUDLUM MODEL ALPHA, BETA, & GAMMA DETECTORS LUDLUM MODEL 44-9-18 AND LUDLUM MODEL 44-9-19 ALPHA, BETA, & GAMMA DETECTORS January 2018 Serial Number PR254331 and Succeeding Serial Numbers LUDLUM MODEL 44-9-18 AND LUDLUM MODEL 44-9-19 ALPHA, BETA,

More information

Radiation Monitoring Systems

Radiation Monitoring Systems Radiation Monitoring Systems Certificate No. 3250 Contents A guide to Southern Scientific radiation monitoring systems Area Gamma & Interlock Systems (page 3) AGM3 AUTOMESS 6150 Contamination Monitors

More information

TRACERCO T402 and T402HR USER MANUAL

TRACERCO T402 and T402HR USER MANUAL TRACERCO T402 and T402HR USER MANUAL Quality Assurance Tracerco UK has accreditation for ISO9001 and ISO14001. Confidentiality Notice Information contained in this publication or as otherwise supplied

More information

Products & Solutions for Military Customers

Products & Solutions for Military Customers Products & Solutions for Military Customers NUCLEAR MEASUREMENT SOLUTIONS FOR SAFETY, SECURITY & THE ENVIRONMENT U.S. Army photo by Sgt. 1st Class Adelita Mead WWW.CANBERRA.COM Products and Solutions for

More information

POSITRON EMISSION TOMOGRAPHY (PET) CENTER MONITORS

POSITRON EMISSION TOMOGRAPHY (PET) CENTER MONITORS RADIATION MONITORING SYSTEMS POSITRON EMISSION TOMOGRAPHY (PET) CENTER MONITORS Featuring: Radiological Assessment Display and Control Software (RADACS) Answers And Reports At Your Fingertips Aptec-NRC

More information

LUDLUM MODEL 44-9 ALPHA, BETA, GAMMA DETECTOR. February 2010 Serial Number PR and Succeeding Serial Numbers

LUDLUM MODEL 44-9 ALPHA, BETA, GAMMA DETECTOR. February 2010 Serial Number PR and Succeeding Serial Numbers LUDLUM MODEL 44-9 ALPHA, BETA, GAMMA DETECTOR February 2010 Serial Number PR090405 and Succeeding Serial Numbers LUDLUM MODEL 44-9 ALPHA, BETA, GAMMA DETECTOR February 2010 Serial Number PR090405 and

More information

Electronic Personal Dosemeter

Electronic Personal Dosemeter Electronic Personal Dosemeter Tomoya Nunomia Hideshi Yamauchi Tetsuo Shibata 1. Introduction Since developing an electronic personal dosemeter that uses a semiconductor detector in 1983, Fuji Electric

More information

Detecting Radiation. Protection through Detection. February Animations in this training work best in Windows XP

Detecting Radiation. Protection through Detection. February Animations in this training work best in Windows XP Saudi Arabia : info_ksa@magusintl.com U.A.E : info_uae@magusintl.com Detecting Radiation Animations in this training work best in Windows XP February 2006 Why Detect Radiation Today? Medicine Imaging Cancer

More information

Radioactivity dosimeter RD01. User's Manual

Radioactivity dosimeter RD01. User's Manual Radioactivity dosimeter RD01 User's Manual 2011 Contents Introduction 2 Technical specifications 4 How does RD01 work? 5 How to use RD01? 7 Power 10 How to carry out measures correctly? 11 Warranty 12

More information

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES:

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES: LEARNING OBJECTIVES: 2.17.01 List the factors which affects an RCT's selection of a portable contamination monitoring instrument. 2.17.02 Describe the following features and specifications for commonly

More information

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

Portable Alpha/Beta Continuous Online Air Monitor (CAM) Aer 5000 Desktop Portable Alpha/Beta Continuous Online Air Monitor (CAM) The Aer5200 monitors the ambient air continuously to detect airborne radioactive aerosols (LLRD). Typical application fields are

More information

RadEye N / NL Personal Highly Sensitive Neutron Radiation Detector

RadEye N / NL Personal Highly Sensitive Neutron Radiation Detector JRT Associates New pocket size neutron radiation detector 5 Nepperhan Avenue, Suite 2B Elmsford, NY 10523 800-221-0111 RadEye N / NL Personal Highly Sensitive Neutron Radiation Detector High sensitivity

More information

Advanced Radiation Detection Equipment

Advanced Radiation Detection Equipment Advanced Radiation Detection Equipment Electronic Dosimeters Personal Radiation Detectors Spectroscopic Personal Radiation Detectors Portable Monitors & Radioisotope Identifiers Radiation Fixed Monitors

More information

Radiation Safety. Product Catalog 2011/2012. Better products. More choices. One company. Fluke Biomedical.

Radiation Safety. Product Catalog 2011/2012. Better products. More choices. One company. Fluke Biomedical. Radiation Safety Product Catalog 2011/2012 451P Pressurized µr Ion Chamber Survey Meter 190N Portable Neutron Survey Meter ASM-990 Advanced Survey Meter Featuring industry-standard Victoreen technology

More information

Personal Radiation Alarm Dosimeter LK Operating Instruction Manual. Contents

Personal Radiation Alarm Dosimeter LK Operating Instruction Manual. Contents Personal Radiation Alarm Dosimeter LK-3600 Operating Instruction Manual Contents 1. Overview.. 1 2. Features 1 3. Equipment Appearance Instructions. 1 4. Working Principle. 1 5. Main Technical Performances

More information

Setting the new standard for personal radiation detection.

Setting the new standard for personal radiation detection. Setting the new standard for personal radiation detection. Thermo Scientific RadEye SPRD Personal Radiation Detector Definitive answers through pin-point accuracy The Thermo Scientific RadEye SPRD personal

More information

Using ALARA Technologies to Solve Everyday HP Challenges

Using ALARA Technologies to Solve Everyday HP Challenges Using ALARA Technologies to Solve Everyday HP Challenges Innovative Industrial Solutions (IIS) Rich Palatine Director; Product Development 9/14/14 Presentation Summary Solving HP Challenges by: Using What

More information

AERIAL RADIATION & CHEMICAL DETECTION SYSTEM. DroneSENSOR TM Series. Particulate Alpha, Beta, Gamma & Airborne Chemicals

AERIAL RADIATION & CHEMICAL DETECTION SYSTEM. DroneSENSOR TM Series. Particulate Alpha, Beta, Gamma & Airborne Chemicals DroneSENSOR TM Series Model ~ DroneRAD-ST TM (Search Tool or Mapping) - Gamma Model ~ DroneRAD-P TM (Air Monitor & Plume Detector) Particulate Alpha, Beta, Gamma & Airborne Chemicals DroneSENSOR TM THE

More information

MetRad1 Handheld Metal/Gamma Detection Unit. Operation Manual. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since 1963 BNC

MetRad1 Handheld Metal/Gamma Detection Unit. Operation Manual. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since 1963 BNC MetRad1 Handheld Metal/Gamma Detection Unit Operation Manual BNC Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since 1963 GENERAL Thank you for purchasing the Model MetRad 1 - Handheld

More information

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR FEATURES: WORLD S ONLY PAG-LEVEL WATER MONITOR MEASURES AT OR BELOW EPA/DHS PAG LEVELS Protective Action Guideline Levels and Military Drinking Water Limits REAL TIME, IN-LINE, CONTINUOUS DETECTS ALPHAS,

More information

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020 Earphones The Modular System for Radioactivity Measurements For the connection to the separate earphone output. This enables the simultaneous operation of external FH 40 G probes and earphone. For the

More information

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020 The Modular System for Radioactivity Measurements FH 40 G/GL Digital Survey Meter FHT 6020 Display Unit Rugged and reliable Versatile multipurpose meter and area monitor Data logging Internal detector

More information

PM1703MO-1A PM1703MO-1B PERSONAL COMBINED RADIATION DETECTOR/DOSIMETER. Operation Manual

PM1703MO-1A PM1703MO-1B PERSONAL COMBINED RADIATION DETECTOR/DOSIMETER. Operation Manual PM1703MO-1 PM1703MO-1A PM1703MO-1B PERSONAL COMBINED RADIATION DETECTOR/DOSIMETER Operation Manual TABLE OF CONTENTS 1 DESCRIPTION AND OPERATION... 4 1.1 Application... 4 1.2 Delivery kit... 5 1.3 Specifications...

More information

RIID capability in the palm of your hand

RIID capability in the palm of your hand RIID capability in the palm of your hand Thermo Scientific RadEye SPRD-GN Personal Radiation Detector Changing the game The Thermo Scientific RadEye SPRD-GN delivers unprecedented detection. The first

More information

Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O N P R O T E C T I O N

Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O N P R O T E C T I O N Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O P R O T E C T I O Berthold Technologies has more than 60 years experience in manufacturing radiation protection measuring

More information

LUDLUM MODEL 26 FRISKER USER S MANUAL. December 2016 Serial Number PF and Succeeding Serial Numbers

LUDLUM MODEL 26 FRISKER USER S MANUAL. December 2016 Serial Number PF and Succeeding Serial Numbers LUDLUM MODEL 26 FRISKER USER S MANUAL December 2016 Serial Number PF001075 and Succeeding Serial Numbers LUDLUM MODEL 26 FRISKER USER S MANUAL December 2016 Serial Number PF001075 and Succeeding Serial

More information

LUDLUM MODEL RK2 RESPONSE KIT. October 2017 Serial Number and Succeeding Serial Numbers

LUDLUM MODEL RK2 RESPONSE KIT. October 2017 Serial Number and Succeeding Serial Numbers LUDLUM MODEL 2241-3RK2 RESPONSE KIT October 2017 Serial Number 238342 and Succeeding Serial Numbers LUDLUM MODEL 2241-3RK2 RESPONSE KIT October 2017 Serial Number 238342 and Succeeding Serial Numbers STATEMENT

More information

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor FEATURES: HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS WORLD S ONLY PAG-LEVEL WATER MONITOR MEASURES AT OR BELOW EPA/DHS PAG LEVELS (EPA s PROTECTIVE ACTION GUIDELINE LEVELS) REAL TIME, IN-LINE, CONTINUOUS

More information

GasAlertMicroClip X3 Specifications

GasAlertMicroClip X3 Specifications GasAlertMicroClip X3 Specifications The instrument must satisfy the following: Physical Specifications Size (h x w x d) Physical size shall be no larger than 4.4 x 2.4 x 1.2 in. / 11.3 x 6.0 x 3.2 cm Weight

More information

LUDLUM MODEL ALPHA, BETA, GAMMA HAND DETECTOR. June 2016 Serial Number and Succeeding Serial Numbers

LUDLUM MODEL ALPHA, BETA, GAMMA HAND DETECTOR. June 2016 Serial Number and Succeeding Serial Numbers LUDLUM MODEL 44-25 ALPHA, BETA, GAMMA HAND DETECTOR June 2016 Serial Number 155835 and Succeeding Serial Numbers LUDLUM MODEL 44-25 ALPHA, BETA, GAMMA HAND DETECTOR June 2016 Serial Number 155835 and

More information

Radiation Safety. Product Catalog 2007/2008. Fluke Biomedical. The accuracy you need from a company you can trust.

Radiation Safety. Product Catalog 2007/2008. Fluke Biomedical. The accuracy you need from a company you can trust. 05-437 PRIMALERT 35 Area Radiation Monitor ASM990 Advanced Survey Meter (ASM) Radiation Safety Product Catalog 2007/2008 190N Portable Neutron Survey Meter Fluke Biomedical. The accuracy you need from

More information

WIDE SEARCH AREA HAND-HELD METAL DETECTION SET

WIDE SEARCH AREA HAND-HELD METAL DETECTION SET NSN: 6665150114797 WIDE SEARCH AREA HAND-HELD METAL DETECTION SET Wide Search Area for Faster and Accurate Screening Operations Search operations allowed even in close proximity of metal reinforced floors

More information

TRACERCO Radiation Monitor

TRACERCO Radiation Monitor TRACERCO Radiation Monitor Instruction and Maintenance Manual for Model No. T402 Customer Notice: Please note that the T402 is NOT an Intrinsically Safe Monitor and should not be confused with the TRACERCO

More information

PRELIMIN INTERNATIONAL

PRELIMIN INTERNATIONAL INTERNATIONAL S.E. International, Inc. P.O. Box 39, 436 Farm Rd. Summertown, TN 38483 USA 1.800.293.5759 931.964.3561 Fax: 1.931.964.3564 www.seintl.com radiationinfo@seintl.com Contents Chapter 1: Introduction

More information

RADCOMM RADIATION DETECTION SYSTEMS. Leading Supplier of Innovative Radiation Detection Systems.

RADCOMM RADIATION DETECTION SYSTEMS.  Leading Supplier of Innovative Radiation Detection Systems. Products Brochure RADCOMM RADIATION DETECTION SYSTEMS Leading Supplier of Innovative Radiation Detection Systems Working in association with RENEWING, REPAIRING, REPLACING www.higginsbalers.com www.radcommsystems.com

More information

LUDLUM MODEL RK RESPONSE KIT. January 2016 Serial Number and Succeeding Serial Numbers

LUDLUM MODEL RK RESPONSE KIT. January 2016 Serial Number and Succeeding Serial Numbers LUDLUM MODEL 2241-2RK RESPONSE KIT January 2016 Serial Number 237627 and Succeeding Serial Numbers LUDLUM MODEL 2241-2RK RESPONSE KIT January 2016 Serial Number 237627 and Succeeding Serial Numbers STATEMENT

More information

Nardalert S3 TM Non-Ionizing Radiation Monitor

Nardalert S3 TM Non-Ionizing Radiation Monitor Patent Pending Nardalert S3 TM Non-Ionizing Radiation Monitor Field Replaceable Sensor Modules Color LCD Display Multi-Color Alarm LED s USB Interface for Data and Charging Comprehensive Software Included

More information

TRACERCO Radiation Monitor. Instruction and Maintenance Manual for Model No. T202

TRACERCO Radiation Monitor. Instruction and Maintenance Manual for Model No. T202 TRACERCO Radiation Monitor Instruction and Maintenance Manual for Model No. T202 Page 2 CONTENTS 1. General Description 4 2. Operational Safety 4 3. Post-Delivery Checks 4 4. Operational Features 5 4.1

More information

DOE 2.17 Contamination Monitoring Instrumentation Study Guide. 00ICP330 Rev. 0 Page 1 of 23

DOE 2.17 Contamination Monitoring Instrumentation Study Guide. 00ICP330 Rev. 0 Page 1 of 23 00ICP330 Rev. 0 Page 1 of 23 Course Title: Radiological Control Technician Module Title: Contamination Monitoring Instrumentation Module Number: 2.17 Objectives: 2.17.01 List the factors which affects

More information

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor NEX-BETA-ABG FACILITY Drinking Water Safety Monitor FEATURES: DETECTS ALPHA, BETA AND GAMMA RADIATION AVAILABLE IN PORTABLE OR INSTALLED VERSION MEASURES AT OR BELOW EPA/DHS PAG LEVELS PROTECTIVE ACTION

More information

CEIA THS 21 series INDUSTRIAL METAL DETECTION SYSTEMS. Superior Detection Capabilities. Maximum Configurability

CEIA THS 21 series INDUSTRIAL METAL DETECTION SYSTEMS.  Superior Detection Capabilities. Maximum Configurability CEIA THS 21 series INDUSTRIAL METAL DETECTION SYSTEMS Superior Detection Capabilities Maximum Configurability Full compliance with HACCP and GMP criteria FDA Title 21CFR Part 11 Compliant Data Security

More information

LUDLUM MODEL 44-7 Alpha, Beta, Gamma Detector. July 2012 Serial No. PR and succeeding Serial Numbers

LUDLUM MODEL 44-7 Alpha, Beta, Gamma Detector. July 2012 Serial No. PR and succeeding Serial Numbers LUDLUM MODEL 44-7 Alpha, Beta, Gamma Detector July 2012 Serial No. PR090405 and succeeding Serial Numbers LUDLUM MODEL 44-7 Alpha, Beta, Gamma Detector July 2012 Serial No. PR090405 and succeeding Serial

More information

Surface Contamination Monitor. Operation Manual

Surface Contamination Monitor. Operation Manual Surface Contamination Monitor Operation Manual 1996, 2005, 2013, 2014, 2015 IMI-International Medcom, Inc. All rights reserved. Contents 1 Introduction...1 How the IMI Inspector Alert Detects Radiation...

More information

Portable Instruments For First Response & In-Situ Analysis of Radiation

Portable Instruments For First Response & In-Situ Analysis of Radiation WWW.NATS-USA.COM Portable Instruments For First Response & In-Situ Analysis of Radiation North American Technical Services Bridging Technology With Latest in Radiation Detection Systems & Solutions The

More information

RadEye B20 RadEye B20-ER Multi-Purpose Survey Meter

RadEye B20 RadEye B20-ER Multi-Purpose Survey Meter Operating Instructions DB-065 E RadEye B20 RadEye B20-ER Multi-Purpose Survey Meter REVISIONS SHEET: Rev. Rev. Dept. Name Rev. Cat. Explanation state resp. page *) 27.07.07 RM&P-E Pij > V 1.26 A 22.07.08

More information

GRAPPLE SCANNER FOR RADIATION IN SCRAP METAL. Model Series ~ GRAPPLE SCAN- GR Models ~ GRAPPLE SCAN- GR-A, -B, -C, & -D

GRAPPLE SCANNER FOR RADIATION IN SCRAP METAL. Model Series ~ GRAPPLE SCAN- GR Models ~ GRAPPLE SCAN- GR-A, -B, -C, & -D FEATURES: WIRELESS COMMUNICATION BETWEEN DETECTOR & CRANE OPERATOR SURFACE SCAN, LOAD ANALYSIS, SEARCH MODES FAST SCAN, REAL TIME ALARM NO MOVING PARTS QUICK CHANGE DETECTOR BETWEEN GRAPPLE HOUSINGS DETECTS

More information

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser >10h Operation with Li-Ion Battery Pack Smart Autozero without Removal the Probe CO Dilution up to 10% Stores up to 250 Complete Analysis

More information

DSP EC Pro. Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems

DSP EC Pro. Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems DSPEC Pro: Advancing the Art of Digital Gamma-Ray Spectroscopy The immense versatility of DSPEC Pro, brought about by the number of unique

More information

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES FEATURES: MOVING AIR FILTER AIRBORNE ALPHA LESS RADON AND BETA/GAMMA PARTICULATES RUGGED, 100% DUTY CYCLE SETTABLE ALARM HIGH THROUGH-PUT UNATTENDED OPERATION 12 WEEKS PRINTED RECORD (Optional) 4 CHANNEL

More information

LUDLUM MODEL 44-2 GAMMA SCINTILLATOR. February 2018 Serial Number PR and Succeeding Serial Numbers

LUDLUM MODEL 44-2 GAMMA SCINTILLATOR. February 2018 Serial Number PR and Succeeding Serial Numbers LUDLUM MODEL 44-2 GAMMA SCINTILLATOR February 2018 Serial Number PR361009 and Succeeding Serial Numbers LUDLUM MODEL 44-2 GAMMA SCINTILLATOR February 2018 Serial Number PR361009 and Succeeding Serial

More information

FLX380-30x FlexTester OTDR

FLX380-30x FlexTester OTDR Features 3rd generation hand-held, all-in-one OTDR, Source, Power Meter, VFL Icon-based LinkMap display with pass/fail for easy network analysis Patented in- or out-of-service testing from a single port

More information

Controls Surface mounted pushbuttons Suitable for gloved use. Buttons Side - On/Off Front Menu Scroll Pin Hole Setup access

Controls Surface mounted pushbuttons Suitable for gloved use. Buttons Side - On/Off Front Menu Scroll Pin Hole Setup access 8.0 Safe-EPD Dosimeter 8.1 Technical data STS Safe-Series Series Field Survey Instruments Instrument Name STS Safe-EPD Dosimeter Description The STS Safe-EPD simulator is a simulated generic Electronic

More information

MeshGuard and MeshGuard Gamma

MeshGuard and MeshGuard Gamma and RAE Systems by Honeywell Battery-Powered Wireless Gas Detector and Radiation Detector Battery-Powered Wireless Gas Detector Key Features Self-forming wireless network; units come online automatically

More information

NEW GENERATION COMPACT HAND HELD METAL DETECTION SET

NEW GENERATION COMPACT HAND HELD METAL DETECTION SET PD140N NEW GENERATION COMPACT HAND HELD METAL DETECTION SET NIJ-0602.02 Compliant FEATURES NIJ Standard - 0602.02 Compliant Compact, Elegant, Robust and Ergonomic Uniform Detection of Magnetic and Non-Magnetic

More information

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET FEATURES

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET FEATURES PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET FEATURES NIJ-0602.02 Standard Compliant Wide Search Area for Faster and Accurate Screening Operations Elegant, Robust and Ergonomic High

More information

For the Safety of Your

For the Safety of Your For the Safety of Your Team in Confined Spaces CSM 5000 Portable Multi-Gas Monitor H 2 S OX CO EX Do it Right Do it Safe Power/Select Button Used for turning the CSM 5000 ON and OFF, accessing download

More information

MODEL 951 RADIATION DETECTOR

MODEL 951 RADIATION DETECTOR P R O D U C T G U I D E MODEL 951 RADIATION DETECTOR I N T R O D U C T I O N About Berkeley Nucleonics Founded in 1963, Berkeley Nucleonics Corporation (BNC), is a leading manufacturer of precision electronic

More information

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI HumiTherm Ultra Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping Mapping Unit Micro PLC Control Unit Touch Panel Touch Operation Panel PPI HumiTherm Ultra GSM Module

More information

LUDLUM MODEL 35 SERIES DIGITAL SURVEY METER USER S MANUAL

LUDLUM MODEL 35 SERIES DIGITAL SURVEY METER USER S MANUAL LUDLUM MODEL 35 SERIES DIGITAL SURVEY METER USER S MANUAL September 2016 LUDLUM MODEL 35 SERIES DIGITAL SURVEY METER USER S MANUAL September 2016 STATEMENT OF WARRANTY Ludlum Measurements, Inc. warrants

More information

stationary dose rate measuring systems

stationary dose rate measuring systems stationary dose rate measuring systems A L M O 1 - A L M O 3 - A L M O 6 A L M O 1 Alarm -channel, stationary dose rate measuring system with external detector Fields of application workplace and room

More information

SVG 2 and Probes. Innovation with Integrity. The new Generation of Semiconductor Radiation Meters and Handheld Radiation Detection Probes

SVG 2 and Probes. Innovation with Integrity. The new Generation of Semiconductor Radiation Meters and Handheld Radiation Detection Probes SVG 2 and Probes The new Generation of Semiconductor Radiation Meters and Handheld Radiation Detection Probes Innovation with Integrity Defence CBRNE General Specification Alarm thresholds for the dose

More information

EasyLog Data Logger Series

EasyLog Data Logger Series EasyLog Data Logger Series Overview EasyLog model EL-USB series products are a line of low cost, compact, battery-operated data loggers with built-in memory and USB interface. Each product in the line

More information

ALTAIR 5X Multigas Detector Product Specification

ALTAIR 5X Multigas Detector Product Specification ALTAIR 5X Multigas Detector Product Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Weight Handling Case material Environmental protection Display

More information

MicroRay IR-100 NEW. Inspection MicroRay IR-100

MicroRay IR-100 NEW. Inspection MicroRay IR-100 Inspection MicroRay IR-100 MicroRay IR-100 RIDGID MicroRay features fast and easy temperature measurements from a comfortable distance. The Infra Red technology allows non-contact, point and read functionality.

More information

The system can be easily relocated by a standard container truck., and re-commissioned by trained engineers typically within a 72-hour period

The system can be easily relocated by a standard container truck., and re-commissioned by trained engineers typically within a 72-hour period Telephone : +44 (01295 756300 Fax : +44 (0)1295 756302 E-Mail : info@wi-ltd.com Website : www.wi-ltd.com WG Entire Truck & Cargo X-Ray Scanning Portal The WG Entire Truck and Cargo X-Ray Scanning Portal

More information