National Industrial Security Monitoring Station Evaluation

Size: px
Start display at page:

Download "National Industrial Security Monitoring Station Evaluation"

Transcription

1 National Industrial Security Monitoring Station Evaluation Listing Evaluation During the UL Listing evaluation we will examine your the monitoring facility, signal handling, means of record keeping, and investigation procedures for compliance with the requirements of UL2050, National Industrial Security Systems. With respect to signal handling, an important part of the UL evaluation is to determine if the personnel responsible for monitoring can perform in accordance with UL2050. To evaluate this capability, we will conduct a service test by creating signals that are sent to the monitoring facility. These tests will be conducted from 5 alarmed locations. Records of signals received from these systems will then be reviewed against the requirements of UL It is important to select sample systems and start the process of compiling records as early as possible so that there is an adequate sample at the time of our evaluation. Standards UL2050 is available for purchase directly from UL. Please call or to one of the following UL staff members. East Coast - Pete Tallman Peter.H.Tallman@.ul.com - James Graff James.C.Graff@ul.com Central - Joe Weller Arthur.A.Weller@ul.com West Coast - Ron Anderson Ronald.C.Anderson@ul.com - Larry Gross Larry.W.Gross@ul.com UL2050 is a serial numbered, restricted distribution document. In your communication, please be sure to document your organization s reason for needing the Standard (i.e. We are an alarm service companying seeking a Listing to UL ) Pre-Evaluation Data Sheets The following series of data sheets are designed to assist you in preparing for your Listing evaluation. They must be completed by the Alarm Service Company (ASC) applying for Listing National Industrial Security Monitoring Station - If you operate a government contractor monitoring station, please complete the National Industrial Security Monitoring Station pages. Central Station Monitoring - If you operate a UL Listed central station or a UL Listed residential monitoring station, please complete the Central Station Monitoring pages

2 Evaluation Day On the day of your UL evaluation, please have available: A qualified technician who has knowledge of the receivers and standby power systems on hand All equipment manuals and instructions A review of the monitored alarm systems will also be conducted. This will include a review of the method that is used to record signal processing. If you have any questions, please contact UL Customer Service at , ext 40227

3 NATIONAL INDUSTRIAL SECURITY MONITORING STATION MONITORING STATION STAFF No. on Duty per Shift Shift Operators Primary Investigators (Enter NA if they are not stationed at the monitoring station) Secondary Investigators (if required) Investigator/Guard Station Communication: Type Single Party Telephone, Cellular Phone or Radio Test Schedule Records: Please include copies of the records that are used for tracking the following signals from alarmed areas or containers: Openings/Closings, Alarms, Trouble Signals Communication Cable: MONITORING STATION EQUIPMENT Are all GCMS communication circuit distribution panels within 50 feet of the GCMS protected against unauthorized access? Yes No Protection: Physical: Electrical: Electrical Protection Reports to GCMS? What is the Extent of Protection of the Electrical Protection? Fire Extinguishers: Monitoring Area A BC Power Room(s) A BC Last Inspection Last Inspection Standby Lighting System: No. of Listed Fixed Units No. of Listed Portable Units Monitoring Station Equipment Room Power Room Investigator Station

4 Clocks: Listed Date/Time Automation Wall Clock Stamps System Time Recording Qty. Time Display Qty. MONITORING STATION AREA DESCRIPTION Number of Remote Entry Points: Sprinkler System: Admittance Log: Watersheds: Has Security-In-Depth (SID) been established? Yes No Physical Boundary and Access/Sight Restriction(s): Remote Signal-Receiving Equipment Location (if applicable): Protection: Physical Electrical Primary Investigator/Guard Station/Location: Secondary Power Room(s) /Enclosure(s): Protection: Physical Electrical Generator Room/Enclosure (if separate from the secondary power room):

5 RECEIVERS MONITORING STATION EQUIPMENT RECEIVERS & AUTOMATION SYSTEM No. Units Mfg. Model AUTOMATION EQUIPMENT Are CPUs Redundant? Yes No Listee: Software Mfg.. Version No. Unit Qty. Mfg. Model CPU CPU Printers Printers Monitor Monitor Interfaces Interfaces Watchdog Timers Watchdog Timers

6 MONITORING STATION POWER SUPPLY PRIMARY POWER SUPPLY Commercial Light & Power Service Permanently Installed Engine Driven Generator(s) Commercial Light & Power Service SECONDARY POWER SUPPLY 1-Hour of Battery (SID Required) 24-Hours Battery 4-Hours Battery and 1 Generator 2 Generators 1. If a receiver cannot tolerate a 30 second loss of power or if an automation system is used, then 15 minutes of battery power is required in addition to the two generators. 2. The specific details for each external power supply must be captured on following pages. External power supplies may be chargers and batteries, a UPS, or generators. Secondary power supplies that are internal to a receiver need only to be examined to determine they provide adequate battery capacity based on the supply configuration indicated above. Describe how the Secondary Power Supply is configured. If batteries are used as part of the secondary power supply, note if the charging source in within the receivers or external to them. Also explain what each source (Battery charger, UPS or generator) is supplying.

7 External Battery Charger Power Supply Group Source Number (USE A SEPARATE PAGE FOR EACH INDEPENDENT SOURCE) (A Power Supply Group exists when standby power supply equipment is servicing a common load.) Battery Charger Manufacturer Model No. Output Rating 1 Output Volts Fuse or Breaker Enter rating if batteries are external to the Charger Total AMPS 2. Use if the power supplies are in parallel. Available 1 Bank No. Batteries Qty. Manufacturer Model No. Total A.H.C. Total Volts Use if more than one bank of batteries are in parallel. TOTAL AHC Load of the Equipment Load from Monthly Test Date of Last Test Duration of Test How Load is Determined Required Run Time Recharge Time Are Batteries Dated? Maintenance

8 UPS Power Supply Group Source Number (USE A SEPARATE PAGE FOR EACH INDEPENDENT SOURCE) (A Power Supply Group exists when standby power supply equipment is servicing a common load.) Type of Supply (Circle One) UPS Battery Charger Manufacturer Model No. Output Rating Output Volts Fuse or Bypass 2 Breaker Enter rating if batteries are external to the UPS 2. Confirm if there is a manual bypass switch or that the UPS can be taken out of service without interrupting power to the load that it supplies. 3. Use if power supplies are in parallel. Load of the Equipment Load from Monthly Test Date of Last Test Duration of Test Maintenance How Load is Determined Required Run Time Actual Run Time Recharge Time Are Batteries Dated?

9 Generator used for Secondary Power Source Number (USE A SEPARATE PAGE FOR EACH INDEPENDENT SOURCE) Generator Unit Mfg. Model No. Rating (A Power Supply Group exists when standby power supply equipment is servicing a common load.) Fuel Type Diesel Gasoline Natural Gas Propane Fuel Availability within 2 Hrs? 12 Hr. Storage Capacity Starting System Transfer Switch Mfg: Automatic Model: Manual Charger for Starting Battery Mfg: Model: Remote Operation Indicator: Lamp Gauge Other Method of Periodic Test Method of Determining Load Generator Personnel Automatic Measured Manual Calculated At Least One Trained Operator on Duty At All Times? Repair or Maintenance Personnel Available Within 2 Hours of Notification? Standby Lighting Fire Extinguishers No. of Fixed Units No. of Portable Units A B Date of Last Inspection

10 UL 2050 MONITORING STATION LOGS AND RECORDS Entry Log Dated Name Organization Reason for Access Time of Entry Time of Departure Emergency Gas or Liquid Fuel Shut Off to Generator Location of Valves Posted Valve Check Procedure Posted Standby Lighting Test Every 30-Days Dated Results Noted Signed All Areas Covered Calculated Load on Batteries and/or UPS Units Calculations Signed Date of Calculations Relevant Comments Battery Test (This includes batteries in any UPS units) Duration 5-Minutes 30-Minutes Start Times Signed Voltage at Beginning of Test Finish Times Relevant Comments Voltage at End of Test Generator Test 30-Minutes Weekly Dated Start Times Finish Times Signed Relevant Times

11

12 ALARM SERVICE COMPANY: DATE: CITY: CENTRAL STATION MONITORING Name and address of the central station or residential monitoring station: UL file Number: Service Center Number: Contact Person: Telephone Number: Means of Communication with Investigators: Frequency of Test of Communication Means: Test Log Available: Yes No Receiving Equipment used for National Industrial Security Systems (NISS): Mfg.: Model: Please include copies of the records that are used for tracking the following signals from alarmed areas or containers: Openings/Closings Alarms Trouble Signals

13 UL COMMON LOGS AND RECORDS Enter Yes, No or NA to each item below PROTECTION SERVICE LISTS Lists of Authorized Users List of Government Contractor s Contacts in the Event of an Alarm List of Certificate Issuer s Service Department Personnel OPENING AND CLOSING RECORDS Authorized Individual User Codes --OR-- Written, Established Opening/Closing Schedule Pre-Entry Identification Procedures (If applicable) Late Opening, Failure to Close Procedures and Reasons TRAINING RECORDS Operators Trained Annually Specific Training Recorded Trainee Names Listed Trainee Names Listed Response Agents Trained Annually Specific Training Recorded Initial Training of Alarm System Users Documented

14 UL COMMON LOGS AND RECORDS CONTRACTS Between ASC and the Designated Monitoring Organization DD Form 254 Contract Security Classification Specification with Monitoring Organization (if applicable) UNESCORTED ACCESS GOVERNMENT CONTRACTOR REPRESENTATIVES LIST AND LOG: At Least 3 Representatives with Their Phone Numbers on Call Name and Phone Number of FSO/SFSC Phone Numbers Verified in Log Once Every 90 Days by Monitoring Station Staff INVESTIGATOR AND OPERATOR STATUS COMMUNICATION LINK TEST LOG: To Investigator Station (From the NISMS or Central Station) Once Every Shift Once Every 4-Hours To Patrolling Investigator (From the NISMS or Central Station) Once Every 30-Minutes To Law Enforcement (From the NISMS or Central Station) Once Every Note: 1. When the Government Contractor Representative is the only investigator then the Communication Link requirement is waived to the 90-day name and phone number verification requirement.

15 SUPERVISION OF SIGNALS FROM ALARM SYSTEMS No. 1 - Name Address Runner Response Time Operates With a Schedule Has Line Security Operates Without a Schedule Mon. Tue. Wed. Thurs. Fri. Sat. Sun. Open Close No. 2 - Name Address Runner Response Time Operates With a Schedule Has Line Security Operates Without a Schedule Mon. Tue. Wed. Thurs. Fri. Sat. Sun. Open Close

16 SUPERVISION OF SIGNALS FROM ALARM SYSTEMS No. 3 - Name Address Runner Response Time Operates With a Schedule Has Line Security Operates Without a Schedule Mon. Tue. Wed. Thurs. Fri. Sat. Sun. Open Close No. 4 - Name Address Runner Response Time Operates With a Schedule Has Line Security Operates Without a Schedule Mon. Tue. Wed. Thurs. Fri. Sat. Sun. Open Close

17 SUPERVISION OF SIGNALS FROM ALARM SYSTEMS No. 5 - Name Address Runner Response Time Operates With a Schedule Has Line Security Operates Without a Schedule Mon. Tue. Wed. Thurs. Fri. Sat. Sun. Open Close INVESTIGATOR DATA 1. Name and address of investigation organization: 2. Contact Person: 3. Telephone Number for Service Tests: 4. Assigned Location of Investigator(s): 5. Is a Duty Roster available? Yes No

Full Service Central Station Fire Alarm Listing Evaluation

Full Service Central Station Fire Alarm Listing Evaluation Full Service Central Station Fire Alarm Listing Evaluation Listing Evaluation A UL Listing project includes: 1. Evaluating the central station facility for compliance with UL 827, Central-Station Alarm

More information

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST DATE: PROJECT NO.: EXPIRATION DATE: STATUS: INFORMATION PROJECT ADDRESS:

More information

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE SUPERVISION OF AUTOMATIC FIRE SPRINKLER SYSTEMS SUPERVISION OF ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS FIRE ALARM AND DETECTION SYSTEMS The Fire Alarm

More information

INSPECTION AND TESTING FORM

INSPECTION AND TESTING FORM INSPECTION AND TESTING FORM Date: Time: SERVICE ORGANIZATION Name: Address: Representative: License No.: MONITORING ENTITY Contact: Monitoring Account Ref. No.: TYPE TRANSMISSION McCulloh Multiplex Digital

More information

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number: 109-B Concord Drive Casselberry, FL 32707 407.830.6500 DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72 Pg 1 of 4 Equity One 11180600 Owner/Representative: WO#: _Customer#: 1550 NE Miami Garden Dr

More information

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers,

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers, NFPA CODE TESTING & INSPECTION Requirements & Recommendations for Licensed Florida Hospitals, Ambulatory Surgery Centers, ICF/IID Healthcare, & In-patient Hospice Facilities per NFPA Life Safety Code 101

More information

FIRE ALARM SYSTEM INSPECTION

FIRE ALARM SYSTEM INSPECTION 13555 Wellington Center Circle Suite 123 Gainesville, VA 20155 T: 1-888-883-2867 F: 703-468-6070 www.vectorsecurity.com FIRE ALARM SYSTEM INSPECTION Upon arrival, contact Vector Security Service Dept.

More information

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions. 11/16/12 TerraView First Revision No. 15-NFPA 720-2012 [ Global Input ] Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

More information

ENGINE GENERATORS AND ACCESSORIES

ENGINE GENERATORS AND ACCESSORIES ENGINE GENERATORS AND ACCESSORIES GENERAL INFORMATION 1.1 This section applies to engine generators and accessories. DESIGN REQUIREMENTS 2.1 The Engineer of Record will consult with the University s Engineering

More information

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Rancho Cucamonga Fire Protection District Prevention Bureau Standard Rancho Cucamonga Fire Protection District Prevention Bureau Standard Title: Fire Alarm and Monitoring Systems Standard # 9-3 Effective: May 2002 Number of Pages: 7 Updated: December 2016 for consistency

More information

The Standard for Remote Supervising Station (SRSS-01) 2007

The Standard for Remote Supervising Station (SRSS-01) 2007 The Standard for Remote Supervising Station (SRSS-01) 2007 Electronic Security Association 2300 Valley View Lane, Suite 230 Irving, TX 75062 888-447-1689 1 The Standard for Remote Supervising Station (SRSS-01)

More information

Nova Scotia Fire Dispatch Minimum Standards (2017)

Nova Scotia Fire Dispatch Minimum Standards (2017) Fire Service Association of Nova Scotia Nova Scotia Fire Dispatch Minimum Standards (2017) July 14, 2017 Scope This document sets out the minimum standards to which fire dispatch operations are expected

More information

Skilled Healthcare Documentation Requirements Life Safety and Fire Protection

Skilled Healthcare Documentation Requirements Life Safety and Fire Protection DATE OF EVALUATION: FACILITY NAME: FACILITY ADDRESS: ADMINISTRATOR: MAINTENANCE DIRECTOR: All required documentation must be written and saved for at least 2 years and some documentation may be required

More information

Functional Performance Test

Functional Performance Test Fire Alarm Control Panel & Fire Alarm Annunciator Panel Notify all building occupants that testing will be conducted. Fire alarm contractor shall have personnel with 2-way radios at the fire alarm control

More information

Fire Alarm System Inspection and Testing Report

Fire Alarm System Inspection and Testing Report Fire Alarm System and ing Report Date of : Time of : 1. PROPERTY INFORMATION: Name of Property: Address: of property: Occupancy Type: Name of property representative: Address: Phone: Fax: E-mail: Local

More information

Mount Laurel Fire Department, Office of The Fire Marshal FIRE WATCH NOTIFICATION

Mount Laurel Fire Department, Office of The Fire Marshal FIRE WATCH NOTIFICATION Mount Laurel Fire Department, Office of The Fire Marshal FIRE WATCH NOTIFICATION (Please Print or Type) PREMISE DATE TIME ADDRESS RESPONSIBLE PERSON PHONE ORDERED BY RECEIVED BY CIRCUIT INTERVALS FIRE

More information

Alarm. A warning of danger. An indication of the existence of a condition that requires immediate action. (SIG-FUN)

Alarm. A warning of danger. An indication of the existence of a condition that requires immediate action. (SIG-FUN) 4 of 326 11/21/2013 1:03 PM First Revision No. 161-NFPA 72-2013 [ Section No. 3.3.11 ] 3.3.11 Alarm. A warning of danger. An indication of the existence of a condition that requires immediate action. (SIG-FUN)

More information

OJD ITB No Attachment E Duress Alarm Equipment Specifications

OJD ITB No Attachment E Duress Alarm Equipment Specifications Duress Alarm Equipment Specifications PART 1 GENERAL 1.1 SECTION INCLUDES A. Duress devices. B. Alarm control panel. C. Signaling devices. 1.2 REFERENCE STANDARDS A. NFPA 70 - National Electrical Code;

More information

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 28 31 00 FIRE ALARM AND SMOKE DETECTION SYSTEMS A. Fire alarm and smoke detection systems 1.2 REFERENCES A. NFPA 72 B. NFPA 101 1.3 REGULATORY REQUIREMENTS A.

More information

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

THE SS90 SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL S S S S S S OLID TATE ECURITIES, INC S S 90 SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED 99Y9 RESET U L RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2 Architectural & Engineering Specifications Control Panel 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality assurance...

More information

JEFFERSON COUNTY PUBLIC SCHOOLS FIRE WATCH PROGRAM

JEFFERSON COUNTY PUBLIC SCHOOLS FIRE WATCH PROGRAM 1 JEFFERSON COUNTY PUBLIC SCHOOLS FIRE WATCH PROGRAM PURPOSE: To minimize potential structural damages and to protect the life safety of all building occupants during periods when the automatic fire alarm

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems OPERATOR OPERATOR OR TROUBLE CONDITION: TO : FIRE PRIORITY 2SYSTEM SYSTEM SIGNALS POWER INDICATOR. SUPERVISORYTROUBLE SILENCED ON D. TO SILENCE SIGNALS: - PRESS " SILENCE". SUPV TBL SYSTEM ACK ACK ACK

More information

*** Inspection *** Please identify yourself as a Cintas representative when arriving onsite.

*** Inspection *** Please identify yourself as a Cintas representative when arriving onsite. Tech Clock-In/Out IVR: 1-877-349-2906 Job #: Tech ID #: 2902 FP Service Instructions Job #: *** Inspection *** You must clock in and out of this job through Cintas's IVR phone system! Call 1-877-349-2906

More information

Fire Alarm Testing and Inspection Report

Fire Alarm Testing and Inspection Report Fire Alarm Testing and Inspection Report Property Name: Property Address: Property Manager: Contact: Phone Number: Central Station: Phone Number: PELICAN ISLE II 35 DOCKSIDE RD. NAPLES, FLORIDA 3110 BILL

More information

Model 17A00 Expansion Enclosure

Model 17A00 Expansion Enclosure HOME AUTOMATION, INC. Model 17A00 Expansion Enclosure Installation Manual Document Number 17I00-1 Rev A March, 2002 Home Automation, Inc. Model 17A00 Expansion Enclosure Installation Manual Document Number

More information

Unified Fire Authority - Fire Prevention Bureau

Unified Fire Authority - Fire Prevention Bureau Unified Fire Authority - Fire Prevention Bureau FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance

More information

Table OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS

Table OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS 901.6 Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective.

More information

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL MADE IN THE U.S.A. U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION SERIAL NUMBER The Cookson Company FIREFLY II PLUS Time Delay Release

More information

A Guide to the Fire Safety Log Book For Small to Medium Business

A Guide to the Fire Safety Log Book For Small to Medium Business A Guide to the Fire Safety Log Book For Small to Medium Business FIRE SAFETY REQUIREMENTS Following the introduction of the Regulatory Reform Order owners, employers and managers are now responsible for

More information

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING THE ILLUMINATOR ILLUMINATOR SERIES IE The Illuminator Series IE is an interruptible lighting inverter. It transfers to inverter mode (battery

More information

Spectron LSN (Life Safety Network) Suggested Specifications

Spectron LSN (Life Safety Network) Suggested Specifications 1. General 1.1 Scope A Dual-Lite Spectron LSN (Life Safety Network) Series Inverter System shall be furnished to provide a reliable source of power, and shall operate during a utility line deficiency without

More information

DO NOT REMOVE THE MONITORS FOR SERVICE! COVER THEM WITH PLASTIC AND TAKE A PICTURE OF THE MONITORS COVERED.

DO NOT REMOVE THE MONITORS FOR SERVICE! COVER THEM WITH PLASTIC AND TAKE A PICTURE OF THE MONITORS COVERED. Tech Clock-In/Out IVR: 919-261-5182 Job #: Tech ID #: 2066 KEC Service Instructions Service Date/Time: 11/01/2016 11:00pm Job #: Technician: Patrick McCarthy* Location: Chili's #0979 Leominster Phone:

More information

DIRECTIVE NO: D-B

DIRECTIVE NO: D-B DIRECTIVE NO: D-B6 100604 1 LOW PRESSURE THERMAL FLUID PLANT AUTOMATED CONTROL SYSTEMS Date of Issue: June 4, 2010 General Details This directive is being issued to owners, licensed contractors, consulting

More information

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number:

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number: DATE OF SUBMISSION TO: Department of Licenses and Inspections Commercial and Industrial Fire Inspection Unit 990 Spring Garden Street, 3 rd Floor, Philadelphia, PA 19123 AP# CITY OF PHILADELPHIA FIRE ALARM

More information

T8602C Chronotherm IV Deluxe Programmable Thermostats

T8602C Chronotherm IV Deluxe Programmable Thermostats T8602C Chronotherm IV Deluxe mable Thermostats INSTALLATION INSTRUCTIONS APPLICATION The T8602 Chronotherm IV Deluxe mable Thermostat provides electronic control of 24 Vac single-stage heating and cooling

More information

B. Section Transfer Switches: Automatic transfer switch.

B. Section Transfer Switches: Automatic transfer switch. SECTION 263213 - ENGINE GENERATORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Packaged engine generator set. B. Exhaust silencer and fittings. C. Remote control panel. D. Battery and charger. E. Weatherproof

More information

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS PART 1 GENERAL 1.1 SECTION INCLUDES A. Fire alarm and smoke detection systems 1.2 REFERENCES A. NFPA 72 B. NFPA 101 1.3 REGULATORY REQUIREMENTS A. System: UL listed B. Conform to requirements of NFPA 101

More information

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 Permit Type: 105.6.54 Control Number: A.0 Effective Date: TITLE: PROPRIETARY

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC2 THRU NVC6 ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx WITH CONTROLINKS CONTROLS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas

More information

16620 EMERGENCY POWER SYSTEMS

16620 EMERGENCY POWER SYSTEMS 16620 EMERGENCY POWER SYSTEMS PART 1: GENERAL 1.01 SUMMARY A. This Section provides the University guidelines for the installation of Emergency Power Systems. B. This standard is developed primarily to

More information

FIRE & LIFE SAFTEY STANDARD

FIRE & LIFE SAFTEY STANDARD Title: Effective Date: 01/01/14 Revised Date: 1/1/14 Code References: Title 16, Chapter 16.16 of the Roseville Municipal Code, NFPA 72 Note: This standard is a summary of Fire Department clarifications

More information

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software OVERVIEW The Keltron LS 7000 Alarm Management System software and computers make up the dispatch portion

More information

Austin Independent School District Police Department Policy and Procedure Manual

Austin Independent School District Police Department Policy and Procedure Manual Policy 8.07 Austin Independent School District Police Department Policy and Procedure Manual Life Safety Systems I. POLICY The proper operations of the AISD Life Safety Systems (LSS) are essential for

More information

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes

More information

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline Moreno Valley Fire Department Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: May 8, 2017 Alarm & Signaling Systems PURPOSE Fire alarm and signaling systems are designed to

More information

Moving to the Cloud: The Potential of Hosted Central Station Services

Moving to the Cloud: The Potential of Hosted Central Station Services Moving to the Cloud: The Potential of Hosted Central Station Services Moving to the Cloud: The Potential of Hosted Central Station Services The global market for alarm monitoring services is expected to

More information

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual ZX1e ZX2e ZX5e Document No. 996-130 Issue 01 user manual MORLEY-IAS ZX2E/ZX5E Fire Alarm Control Panels Table of Contents 1 INTRODUCTION... 4 1.1 NOTICE... 4 1.2 WARNINGS AND CAUTIONS... 4 1.3 NATIONAL

More information

Building Name: Our Lady of Sorrows Date: July 10, 2013

Building Name: Our Lady of Sorrows Date: July 10, 2013 1 E1. FIRE ALARM SYSTEM ANNUAL TEST AND INSPECTION REPORT (Reference: 5.1.2) Building Name: Our Lady of Sorrows Date: July 10, 2013 Address 19 Mohns Avenue Petawawa, ON System Manufacturer: Siemens Model

More information

9S / 9E Inspection Worksheets. The fire department should complete the following sheets prior to inspection date

9S / 9E Inspection Worksheets. The fire department should complete the following sheets prior to inspection date 9S / 9E Inspection Worksheets The fire department should complete the following sheets prior to inspection date 9S/E Rating Inspection Work Sheets Date of Inspection Fire District Name Department Name

More information

Deluxe Programmable Thermostats

Deluxe Programmable Thermostats Deluxe mable Thermostats T8602D INSTALLATION INSTRUCTIONS APPLICATION The T8602D IV Deluxe mable Thermostat provides electronic control of 24 Vac single-stage heating and cooling systems or 750 mv heating

More information

ILLUMINATOR EM. CENTRAL LIGHTING INVERTER 1000 VA/W through 2800 VA/W 98% Efficiency!

ILLUMINATOR EM. CENTRAL LIGHTING INVERTER 1000 VA/W through 2800 VA/W 98% Efficiency! ILLUMINATOR EM CENTRAL LIGHTING INVERTER 1000 VA/W through 2800 VA/W 98% Efficiency! THE ILLUMINATOR SERIES EM The Illuminator Series EM is a fast transfer Emergency Lighting Inverter utilizing Myers Power

More information

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

THE SS90 SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL S S S S S S S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED U 99Y9 RESET L RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

Life Safety Code Potpourri

Life Safety Code Potpourri Life Safety Code Potpourri JAMES P. LOVELAND P.E. MINNESOTA DEPARTMENT OF HEALTH Engineering Services Section FEDERAL MONITORING SURVEYS 2007 2008 2009 No. of FMSs 20 20 20 No. of Deficiencies 332 252

More information

7-Day. Digital Thermostat. residential. & 2-cool

7-Day. Digital Thermostat. residential. & 2-cool Digital Thermostat residential THERMOSTAT T1100FS 7-Day PROGRAMMABLE up to 2-heat & 2-cool PUMP Control up to 2 Heat & 2 Cool Stages 7-Day Programmable 4 Settings/Day Auto Changeover 5 minute Built-In

More information

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater APPROVED BY: JBJ Precept EN Fire Detection/Alarm Panel & Precept EN Repeater Logbook PAGE 1 of 19 List of Contents 1. FIRE ALARM SYSTEM MAINTENANCE... 3 2. USER RESPONSIBILITIES... 3 2.1. RESPONSIBLE PERSON...

More information

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH CONTROL PANEL INTERFACE USING THE AUTO/OFF/MANUAL SWITCH With the switch set to AUTO, the engine may crank and start at any time without warning. Such automatic starting occurs when utility power source

More information

CERTIFICATION BULLETIN

CERTIFICATION BULLETIN File: ULC-S527-11 ULC-G5.2 June 1, 2012 CERTIFICATION BULLETIN 2012-04 Effective Date Announcement CAN/ULC-S527-11, 3 rd Edition of the Standard for Control Unit for Fire Alarm Systems To: Subscribers

More information

Date Issued: December 14, 2017 Revision: 2.1

Date Issued: December 14, 2017 Revision: 2.1 2.1 1. Introduction A is implemented to ensure the fire safety of building occupants or a building area when the Fire Alarm System or a Fire Protection System has been temporarily disabled due to malfunction,

More information

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

SOLID STATE SECURITIES, INC. THE SS90 SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL S S S S S S LISTED L * PATENT PENDING S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT U 99Y9 RESET RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

Changes in NFPA

Changes in NFPA Changes in NFPA 72-2002 2002 Oregon Fire Code Committee November 25, 2003 Michael B. Baker, SET Automatic Fire Alarm Association MikeBaker@afaa.org 2003 Michael B. Baker 1 Table of Contents 1. Administration

More information

INTEGRATED LIFE SAFETY COMPLIANCE TESTING AND ITS PROCEDURES

INTEGRATED LIFE SAFETY COMPLIANCE TESTING AND ITS PROCEDURES INTEGRATED LIFE SAFETY COMPLIANCE TESTING AND ITS PROCEDURES By: Mehrdad Ghods Integrated Engineering Student Sept. 06, 2002 University of British Columbia Vancouver, BC i PREFACE: The purpose of this

More information

Halton SAFE / 7.14 user guide and installation instructions

Halton SAFE / 7.14 user guide and installation instructions Halton SAFE / 7.14 user guide and installation instructions VERIFIED SOLUTIONS BY H A LTO N Enabling Wellbeing Table of contents 1 System description 3 2 User Accounts 4 3 Main menu 7 3.1 Main menu - Change

More information

Bold items are particular to the City of Euless

Bold items are particular to the City of Euless EULESS FIRE DEPARTMENT FIRE MARSHAL S OFFICE INFORMATION LINE: Revised 8/2004 Fire Chief Lee Koontz Fire Marshal Paul Smith EFD-FMO 3-1 2003 International Fire & Building Code as Amended NFPA Standards

More information

VSC Fire & Security, Inc.

VSC Fire & Security, Inc. JOB#: 12775876 VSC Fire & Security, Inc. 10640 Iron Bridge Road, Suite G Jessup MD 20794 (301) 575-1500 www.vscfs.com Important: Deficiencies, Comments and Explanations any FAIL or NEGATIVE responses are

More information

FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures

FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures Building Name: Building Address: Plan Prepared By (please print): Date: Revision Date Comments Approval FIRE SAFETY MAINTENANCE

More information

Chapter 4: Fire Protection Systems

Chapter 4: Fire Protection Systems Chapter 4: Fire Protection Systems Automatic Extinguishing Systems (Fire Sprinklers) One of the most important aspects of a storage warehouse inspection is ensuring that the automatic extinguishing system

More information

T8600D Chronotherm IV Deluxe Programmable Thermostats

T8600D Chronotherm IV Deluxe Programmable Thermostats T8600D Chronotherm IV Deluxe mable Thermostats APPLICATION INSTALLATION INSTRUCTIONS The T8600 Chronotherm IV Deluxe mable Thermostat provides electronic control of 24 Vac singlestage heating and cooling

More information

Norfolk Fire Department Fire Prevention & Information

Norfolk Fire Department Fire Prevention & Information Norfolk Fire Department Fire Prevention & Information For Permits and Inspections Contact (508)528-3207 EFFECTIVE JANUARY 1, 2015, THE NORFOLK FIRE DEPARTMENT, BY STATE REGULATIONS, NO LONGER ISSUES PERMITS

More information

FIRE IMPAIRMENT NOTICE

FIRE IMPAIRMENT NOTICE Notification of Fire System Isolation FIN NORA No. Complete Fire Impairment Notice (FIN) before any impairment. Note 3 business days notice is required. Submit the FIN to the BAC Airport Facilities on

More information

Owner/Operator Guide for Successful Sprinkler and Fire Pump Systems

Owner/Operator Guide for Successful Sprinkler and Fire Pump Systems Owner/Operator Guide for Successful Sprinkler and Fire Pump Systems Adam Olomon, P.E. Associate Consultant Fire & Life Safety and Fire Protection Introduction Adam Olomon Licensed Professional Engineer

More information

7.0 SAMPLE PERMITS, FORMS AND CHECKLISTS SELF INSPECTION CHECKLIST

7.0 SAMPLE PERMITS, FORMS AND CHECKLISTS SELF INSPECTION CHECKLIST 7.0 SAMPLE PERMITS, FORMS AND CHECKLISTS The Permits, forms and checklists shown within this section are an example of the type of controls that should be in place to help effectively manage Health & Safety

More information

Fire Alarm, Water Flow Alarm & Signaling Systems

Fire Alarm, Water Flow Alarm & Signaling Systems Orange County Fire Authority Community Risk Reduction 1 Fire Authority Road, Building A, Irvine, CA 92602 www.ocfa.org 714-573-6100 Fire Alarm, Water Flow Alarm & Signaling Systems Guideline D-03 Serving

More information

FIRE SAFETY LOG BOOK

FIRE SAFETY LOG BOOK FIRE SAFETY LOG BOOK Regulatory Reform (Fire Safety) Order 2005 If you own, manage or operate a business, you will need to comply with fire safety law. The main law is the Regulatory Reform (Fire Safety)

More information

Facilities Management

Facilities Management Facilities Management Policy Number: 700.4 Title: Fire Protection & Life Safety Inspection Policy Implementation Date: August 1 st, 2008 Last Revised: September 14 th, 2017 Last Audited: August, 2017 Introduction

More information

PARAFFIN/DIESEL FORCED AIR HEATERS

PARAFFIN/DIESEL FORCED AIR HEATERS PARAFFIN/DIESEL FORCED AIR HEATERS PT-125T-KFAEU PT-45-KFAEU Powerful Instant Heat - High performance fan Safe & Efficient - Auto shut off if power is interrupted or flame is extinguised Quality Construction

More information

SECTION EMERGENCY POWER SYSTEMS

SECTION EMERGENCY POWER SYSTEMS SECTION 16620 EMERGENCY POWER SYSTEMS A. Standby Engine/Generator Systems 1. Installations of stationary engine/generator (e/g) systems shall be designed in strict accordance with ANSI/NFPA 70 - National

More information

APPENDIX H (DESIGN SUBMISSION CRITERIA)

APPENDIX H (DESIGN SUBMISSION CRITERIA) APPENDIX H (DESIGN SUBMISSION CRITERIA) FIRE ALARM SYSTEM As per ACCORD standard Part 5, section 5.7 Fire Alarm System Design to be verified by ACCORD Chief Safety Inspector. Testing of the installation

More information

Fire System Impairment Policy

Fire System Impairment Policy Fire System Impairment Policy Purpose: To establish procedures to be followed, when a fire protection or suppression system is taken out of service, due to construction, alteration, power outage, repair,

More information

Batt-Safe Battery String Monitoring System

Batt-Safe Battery String Monitoring System Batt-Safe Battery String Monitoring System Technical White Paper October 2010 Introduction Battery monitoring systems are categorized as either cell monitors or string monitors. Battery cell monitors provide

More information

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018 STANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018 STANDARD INFORMATION Standard Number: NFPA 72 Standard Name: National Fire Alarm and Signaling Code Standard Edition and Issue Date: 2016 Edition

More information

AIRPORT OFFICE BUILDING. Smoke Control System. Testing Procedures Manual. September 10, 2016

AIRPORT OFFICE BUILDING. Smoke Control System. Testing Procedures Manual. September 10, 2016 IMPACT ENGINEERING, INC. AIRPORT OFFICE BUILDING Smoke Control System Testing Procedures Manual September 10, 2016 All Rights Reserved This manual is protected by the U.S. Copyright Law (Title 17 United

More information

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad.

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad. SYSTEM USER GUIDE SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad. IS THIS A FALSE ALARM? YES NO displays. REAL ALARM If

More information

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL Firefly II Multi Voltage RELEASE DEVICES Firefly II & IIB-MV INSTALLATION MANUAL GENERAL DESCRIPTION: S/N The The Cookson Company Firefly II-MV time delay release devices are designed for use on rolling

More information

Programmable Electronic Thermostat

Programmable Electronic Thermostat INSTRUCTION MANUAL Programmable Electronic Thermostat We thank you for trusting Aube technologies and hope that you will be entirely satisfied. For any questions concerning the TH141A-HC-28 progammable

More information

Deluxe Programmable Heat Pump Thermostat T8611M

Deluxe Programmable Heat Pump Thermostat T8611M APPLICATION Deluxe mable Heat Pump Thermostat T8611M INSTALLATION INSTRUCTIONS The T8611M Deluxe mable Heat Pump Thermostat provides electronic control of 24 Vac single-zone two compressor or two speed

More information

a) Establishment of emergency procedures to be followed at the time of an emergency;

a) Establishment of emergency procedures to be followed at the time of an emergency; 5.10 Fire Safety 5.10.1 Introduction The Corporation is responsible for carrying out the provisions of the Ontario Fire Code. This section outlines our responsibilities as well as inspections and testing

More information

Facilities Services Utilities Shutdown Request Form

Facilities Services Utilities Shutdown Request Form Page 1 of 6 Facilities Services Utilities Shutdown Request Form Please complete all the fields before submitting the form to the shutdown coordinator. If you require additional space, please attach a separate

More information

SMALL WORKS PROJECT REQUEST FOR SEALED BIDS

SMALL WORKS PROJECT REQUEST FOR SEALED BIDS SMALL WORKS PROJECT REQUEST FOR SEALED BIDS PIERCE COUNTY FIRE PROTECTION DISTRICT #22 18421 OLD BUCKLEY HIGHWAY BONNEY LAKE, WA 98391 (253) 863-1800 (253) 863-1848 (FAX) Date Bid Requested: 5/24/2012

More information

IMPORTANT Read and save these instructions. OWNER S GUIDE. ComfortSense 5000 Series Models L5711U and L5732U Programmable Touch Screen Thermostats

IMPORTANT Read and save these instructions. OWNER S GUIDE. ComfortSense 5000 Series Models L5711U and L5732U Programmable Touch Screen Thermostats 2007 Lennox Industries Inc. Dallas, Texas, USA OWNER S GUIDE ComfortSense 5000 Series Models L5711U and L5732U Programmable Touch Screen Thermostats IMPORTANT Read and save these instructions. 506067 01

More information

Quick Programmer s Manual

Quick Programmer s Manual Version 2.604 (31/03/05) p1 Quick Programmer s Manual 2005. Inner Range Pty. Ltd. Part Number: 630048V2 p2 Version 2.604 (31/03/05) TABLE OF CONTENTS. 1. PROGRAMMING FLOWCHART. The following flowchart

More information

Procedure DESCRIPTION/OVERVIEW

Procedure DESCRIPTION/OVERVIEW Applies To: UNMH Responsible Department: Life Safety Revised: 07.08.16 Procedure Patient Age Group: (X ) N/A ( ) All Ages ( ) Newborns ( ) Pediatric ( ) Adult DESCRIPTION/OVERVIEW To assure the safety

More information

INITIALIZATION / INSTALLATION

INITIALIZATION / INSTALLATION INITIALIZATION / INSTALLATION REMOTE CONTROL The remote control has a range of approximately 50 ft. (15.25m); it does not have to be pointed at the fireplace and can pass through most obstacles (including

More information

CONTENTS AUTOMATIC TRANSFER SWITCHES

CONTENTS AUTOMATIC TRANSFER SWITCHES CONTENTS AUTOMATIC TRANSFER SWITCHES PART 1 GENERAL 1.1 Related Documents 1.2 Summary 1.3 References 1.4 Quality Assurance 1.5 Submittals 1.6 Delivery, Storage and Handling 1.7 Instructions And Training

More information

I. Scope: II. Environmental Health and Safety Fire Alarm System Impairment Program - Guideline Revision Date: April, 2018

I. Scope: II. Environmental Health and Safety Fire Alarm System Impairment Program - Guideline Revision Date: April, 2018 Environmental Health and Safety Fire Alarm System Impairment Program - Guideline Revision Date: April, 2018 Prepared by: EH&S The probability of casualties and major structural damage increases when fire

More information

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement of 1 9/22/2014 1:38 PM Second Revision No. 104-NFPA 72-2014 [ Section No. 3.3.3 ] 3.3.3 Accessible, Readily (Readily Accessible). Capable of being reached quickly for operation, renewal, or inspections

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

SS90 SERIES CONTROLS MODEL C INSTALLATION MANUAL S S S SS O L I D S S90 TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED U L 99Y9 RESET RELEASING DEVICE SOLID STATE SECURITIES, INC. "SS90" SERIES CONTROLS MADE IN THE U.S.A. MODEL

More information

Sample Evacuation I Fire Safety Plan

Sample Evacuation I Fire Safety Plan Sample Evacuation Fire Safety Plan Sample Building Name 555 Main Street Grand Rapids, Ml 49503 Facility Emergency Coordinator: John Doe, 616-456-XXXX Fire Evacuation Plan Fire Alarm Description-This facility

More information

SECTION (13730) - INTRUSION DETECTION

SECTION (13730) - INTRUSION DETECTION PART 1 GENERAL 1.01 SUMMARY A. Section Includes: SECTION 28 16 00 (13730) - INTRUSION DETECTION 1. Intrusion Detection Sensors 2. Signal Equipment 3. System Controls 4. Alarm Displays 5. Alarm Indicating

More information