Fire Safety and Evacuation Plan
|
|
- Mae Gregory
- 6 years ago
- Views:
Transcription
1 AUDIT OF BUILDING RESOURCES The following pages provide a description of the fire safety equipment installed in the building including: Fire Alarm and Detection Systems Central Station (Fire Alarm System Monitoring) Standpipe Systems Sprinkler Systems Portable Fire Extinguishers Automatic Extinguishing Systems Emergency Lighting Building Emergency Generator Exits from Floor Areas Fire-Fighters Elevators Smoke Control Equipment To provide information on the location of other equipment and devices refer to Schematic Drawing in Section VI, Appendix G. SECTION I Page 10
2 Fire Alarm and Detection System: Manufacturer: Cerberus Pyrotronics Model: MXL - IQ Type:??Single-stage???Two-stage? Supervised: Yes? No?? Location of Main Panel: Location of Annunciator Panel(s): Main Electrical Room Front Lobby Sprinkler valve supervision: Yes # Zones: Eleven (11) Upon activation of the fire alarm system, the following will occur:??alarm will be transmitted to the Reek Building s panel which will send a signal to the central monitoring station??hvac system will shut down??bells and Strobe lights will be activated in the building??strobe Light on the building South exterior will flash to identify to Fire Department which building is in alarm Location of Fire Alarm Devices are as follows: DEVICE Manual Pull Stations LOCATION All Building Exits Smoke Detectors Air Ducts Various Rooms Heat Detectors Not Applicable Refer to Schematic Drawing Section VI, Appendix G SECTION I Page 11
3 Fire Alarm System Monitoring: Name of Monitoring Damar System Number Company: Address: 506 Christina Street, Sarnia, Ontario Telephone: (519) In the event of an alarm the Fire Alarm Monitoring Station will notify the following in order: 1. Chatham Fire Department - Global 2. SNC-Lavalin ProFac Inc Morris Galick Morris Galick Cell SNC-Lavalin ProFac Call Centre Standpipe and Hose System: Not Applicable at this Building Provide details on:??the size and location of fire hose connections??the size and location of hoses in hose cabinets??fire department pumper connection(s)??location of fire protection system isolation valves Sprinkler System: Provide details on:??sprinkler system type Wet?? Dry????Location of main isolation control valves Boiler / Mechanical room??main supply shut-off location: Boiler / Mechanical room??test valve Boiler / Mechanical room locations: SECTION I Page 12
4 ??Location of fire department North side of Building connection??system coverage Full?? Partial?? If partial coverage, describe sprinklered areas: Automatic Kitchen Extinguishing System(s): Not Applicable at this Building Location(s): Name of Company: Model: Extinguishing Agent: Coverage: Location of Manual Pull- Handle: Type of Fuel for Cooking: Automatic Fuel Shut-Off: Yes?? No?? Smoke Control System: Stairwell Pressurized Yes? No?? Elevator Shaft Yes? No?? Pressurized Smoke Shafts Yes? No?? Other Information Emergency Lighting (Battery Type): Manufacturer: Model: Type: SECTION I Page 13
5 Installed in the following areas: First Floor Electrical Room, Second Floor Electrical Room Building Emergency Generator: Not Applicable at this Building Provided Yes? No?? Automatic?? Manual? Location: Equipment Fuel: Make and Model of Emergency Generator Is emergency power provided to all elevator cars Yes? No?? simultaneously? Is emergency power provided to smoke control pressurization N/A fans? Other systems provided with emergency power? Shut off Controls: Location of Natural Gas Shut- Off Location of Hydro Shut-Off Location of Water Shut-Off Exterior of North West corner of building Old Agronomy Exterior Sub Station Ground Floor North Boiler Room Portable Fire Extinguishers: Type Floor Location Number Multi-Purpose Dry Chemical 1 st Floor Class A, B and C Fires South Exit C West Exit C East Exit C North Exit C Kitchen C Room SECTION I Page 14
6 Storage Room #151 Operating Room Mechanical Room 2 nd Floor South Exit North Exit Mechanical Room C C C C C C Private Fire Hydrants: There are a total of 18 fire hydrants throughout the complex. Refer to Schematic Drawing Section VI, Appendix G for exact locations. NOTE: The main shut off for the Hydrant System is located in the Valve Chamber on the front lawn at South East Corner of Steckley Hall. Elevators: Make: Otis Make: Type: Hydraulic Type: Capacity: 15 Capacity: Location: East Centre Core Location: Serves: Ground and Second Floors Serves: Exits from all Floor Areas: (refer to Schematic Drawing in Section VI, Appendix G for locations) XXXXXXXXXXXXXXXX Basement Number of Exits Available Ground Floor Number of Exits Available Typical Floor Above Grade Number of Exits Available SECTION I Page 15
7 SECTION I Page 16
Fire Protection Coffee Break Training May 2016
Fire Protection Coffee Break Training May 2016 Introduction High-Rise Requirements Questions and Answers Agenda Overview Site Fire Access Aerial Access Power/Back-up Power Elevators and Access Sprinklers
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST FIRE AND LIFE SAFETY SYSTEMS FOR STRUCTURES FIVE OR MORE STORIES IN HEIGHT AND LESS THAN 75 FEET IN HEIGHT FROM THE POINT
More informationMINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry
MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Fire Alarm Systems Plan Review Checklist Date: Permit Number: Business Name: Address: Fire Alarm System Submittal
More informationFIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES
FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES 1. The major objective is to provide an acceptable degree of life safety from fire in existing senior citizen lodges. This document
More informationModule 9: Ontario Building Code Fire Fighting Provisions
Ontario Building Code (OBC) 1. Sprinklers 2. Standpipes 3. Fire Alarms 4. Entrances Ontario Building Code (OBC) 1. Sprinklers 2. Standpipes 3. Fire Alarms 4. Entrances 1. Sprinklers i) Sprinkler Systems
More informationFIRE SAFETY PLAN. BUILDING NAME: Pathobiology / AHL BUILDING NUMBER: 089. DATE: 15-August-10 FPO #2
FIRE SAFETY PLAN BUILDING NAME: Pathobiology / AHL BUILDING NUMBER: 089 DATE: 15-August-10 FPO #2 INDEX Introduction 2 Locations of Fire Safety Plans 3 Forward 4 Audit of Building Data 5-6 Fire Fighting
More informationTEN STEP PROCESS PREPARING FIRE SAFETY PLANS
TEN STEP PROCESS PREPARING FIRE SAFETY PLANS STEP 1 CONDUCT FIRE SAFETY AUDIT IDENTIFY BUILDING FEATURES AND HUMAN RESOURCES. STEP 2 APPOINTMENT OF SUPERVISORY STAFF IDENTIFY TRAINED SUPERVISORY STAFF
More informationSkilled Healthcare Documentation Requirements Life Safety and Fire Protection
DATE OF EVALUATION: FACILITY NAME: FACILITY ADDRESS: ADMINISTRATOR: MAINTENANCE DIRECTOR: All required documentation must be written and saved for at least 2 years and some documentation may be required
More informationNYU RESIDENTIAL FIRE SAFETY PLAN PART I - BUILDING INFORMATION SECTION
BUILDING ADDRESS: BUILDING OWNER: Name: Address: Telephone : NYU RESIDENTIAL FIRE SAFETY PLAN PART I - BUILDING INFORMATION SECTION Greenberg Hall 545 First Avenue, NY, NY, 10016 New York University 70
More informationFIRE SAFETY PLAN PART 1 BUILDING INFORMATION SECTION
FIRE SAFETY PLAN PART 1 BUILDING INFORMATION SECTION BUILDING ADDRESS: 70 74 Morningside Drive East Campus BUILDING OWNER / REPRESENTATIVE: Name: Trustees of Columbia University Address: 535 West 116 th
More informationNew Construction Fire Inspection Process
New Construction Fire Inspection Process This document is intended to provide the Owner, Designer, and/or Contractor of new construction with an outline of required fire inspections and with the specific
More informationCOURSE SYLLABUS FIRE ALARM AND FIRE SUPPRESSION SYSTEMS CORRESPONDENCE COURSE
COURSE SYLLABUS FIRE ALARM AND FIRE SUPPRESSION SYSTEMS CORRESPONDENCE COURSE 100130 Description The first part of the course presents the requirements for fire alarm systems. It describes the buildings
More informationProject No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10
Belleville, Ontario Page 1 of 10 1 GENERAL 1.1 GENERAL REQUIREMENTS.1 The General Conditions of CCDC2-2008, and the General requirements of Division 1, form part of this Section and must read in conjunction
More information9/23/ :47 AM. Second Revision No NFPA [ New Section after ] Submitter Information Verification. Committee Statement
Second Revision No. 5501-NFPA 5000-2016 [ New Section after 29.2.1.2 ] 29.2.1.3 Bathtubs, bathtub-shower combinations, and nonemergency showers shall be provided with grab bars in accordance with the provisions
More informationFraternity, Sorority and Dormitory Buildings R-2 Fire and Life Safety Standards Inspection Form Fire Code of New York State (19 NYCRR Part 1225.
Fraternity, Sorority and Dormitory Buildings R-2 Fire and Life Safety Standards Inspection Form Fire Code of New York State (19 NYCRR Part 1225.1) House Name Date Address Inspector(s) No. of Residents
More informationSt. John s University Fire Safety Plan
Fire Safety Plan Kelleher Center Kelleher Center page 2 St. John s University Fire Safety Plan Part 1-Building Information Section Kelleher Center 300 Howard Ave. Staten Island, N.Y. 10301 Fire Safety
More informationFIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY
FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY PLAN REVIEWS SITE PLANS: 1) Access to buildings (Volume V NC Building Code sections 602.6.1
More informationFIRE SAFETY PLAN PART 1 BUILDING INFORMATION SECTION. Type of Construction: Combustible Non-Combustible
FIRE SAFETY PLAN PART 1 BUILDING INFORMATION SECTION BUILDING ADDRESS: Sigma Phi Epsilon (SPE) - 550 West 113 th Street BUILDING OWNER / REPRESENTATIVE: Name: Trustees of Columbia University Address: 535
More informationFIRE SAFETY PLAN. Building Name. Address. Prepared By. Date Prepared. Page 1 of 36
FIRE SAFETY PLAN Building Name Address Prepared By Date Prepared Page 1 of 36 INTRODUCTION Fire safety is an important responsibility. The implementation of the fire safety plan helps to ensure effective
More informationGENERAL AREAS OF INSPECTION
This information is intended to assist you in preparation for the annual high-rise inspection. This is not a complete list and the Inspector may identify other conditions or issues in the building that
More information2017 Annual Fire Safety Report. Housing and Residential Life Annual Fire Safety Report information
2017 Annual Fire Safety Report Housing and Residential Life Annual Fire Safety Report information Sec. 668.49 Institutional fire safety policies and fire statistics *************************************************************************************
More informationINTEGRATED LIFE SAFETY COMPLIANCE TESTING AND ITS PROCEDURES
INTEGRATED LIFE SAFETY COMPLIANCE TESTING AND ITS PROCEDURES By: Mehrdad Ghods Integrated Engineering Student Sept. 06, 2002 University of British Columbia Vancouver, BC i PREFACE: The purpose of this
More informationSt. Vincent s Health System Page 1 of 6
St. Vincent s Health System Page 1 of 6 TITLE: Fire Plan Code Red FACILITY: St. Vincent s East FUNCTION: ORIGINATING DEPT: HOSPITAL SHARED POLICY? EFFECTIVE DATE: _X Yes No DOCUMENT NUMBER: 801 ORIGINATION
More informationINITIAL FIRE SAFETY ASSESSMENT
INITIAL FIRE SAFETY ASSESSMENT Factory Plot No -246-249, Adamjee EPZ, Siddhirganj, Narayanganj Narayanganj 17 Jul 2016 The Alliance for Bangladesh Worker Safety Page 1/17 Factory 17 Jul 2016 Introduction
More informationRancho Cucamonga Fire Protection District Prevention Bureau Standard
Rancho Cucamonga Fire Protection District Prevention Bureau Standard Title: Fire Alarm and Monitoring Systems Standard # 9-3 Effective: May 2002 Number of Pages: 7 Updated: December 2016 for consistency
More informationHIGH-RISE RETROFIT ORDINANCES - NO and NO
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LAMC 91.8604 Effective: 9-06-90 DOCUMENT NO. P/BC 2002-054 Revised: 4-15-03 Previously Issued As: MGD 88 HIGH-RISE RETROFIT ORDINANCES - NO.
More informationGuideline. Fire Safety Plan
Fire Safety Plan Guideline Brantford Fire Department Standard Template for Fire Safety Plan Development This document must be customized to fit the requirements of your building. Plans that are not customized
More informationRequirements for Smoke Detector / Carbon Monoxide/ Fire Extinguisher Certification
Requirements for Smoke Detector / Carbon Monoxide/ Fire Extinguisher Certification In order to successfully pass the inspection, your property will need to meet all regulations mandated by the state and
More informationFollowing are the systems proposed as per NBC & Local Fire Authority:
1. OBJECTIVES AND STRATEGIES OF THE FIRE PROTECTION DESIGN This report describes the design parameters, system requirements of fire protection system for mixed occupancy (Assembly + Business) building
More informationSCHEDULE. Essential Safety Measures taken from Schedule 9 of the Building Regulations PART 1 BUILDING FIRE INTEGRITY
SCHEDULE Essential s taken from Schedule 9 of the Building Regulations 2006 43 PART 1 BUILDING FIRE INTEGRITY 1 Building elements required to satisfy prescribed fire-resistance levels 2 Materials and assemblies
More informationSmoke Detector Activation of any smoke detector shall start the alarm verification mode.
Description: The purpose of the section is to provide the UMCP Design Standards for the design and implementation of Fire Alarm Systems at the UMCP campus. Related Sections: TBD Effective Date: July 10,
More informationFull Service Central Station Fire Alarm Listing Evaluation
Full Service Central Station Fire Alarm Listing Evaluation Listing Evaluation A UL Listing project includes: 1. Evaluating the central station facility for compliance with UL 827, Central-Station Alarm
More informationFinal EC Inspection Report 03/2010
2491 Alluvial Avenue, Suite 59 Clovis, California 93611 Tel: (559)392-2838 - Fax: (559)325-7599 Contractor License #933910 (C-10/C-16) Final EC.02.03.05 Inspection Report 03/2010 This Final Report Covers
More informationSAMPLE FIRE SAFETY PLAN. ABC Manufacturing Ltd. 123 Main Street Steinbach, Manitoba. Prepared by: John Smith Last reviewed: Bill Jones 2014
SAMPLE FIRE SAFETY PLAN ABC Manufacturing Ltd. 123 Main Street Steinbach, Manitoba Prepared by: John Smith 2011 Last reviewed: Bill Jones 2014 Page 1 of 19 Table of Contents 1. Building Information 2.
More informationChecklist For Building Inspection & Fire Safety
INSPECTION CHECKLIST Date of Inspection: Location/Address: Weather Condition: Inspector: AFTER COMPLETING YOUR INSPECTION, TRANSFER YOUR CONCERNS/OBSERVATIONS TO THIS AREA Facility: Name: Staff Contact:
More information2012 OBC Changes. Summary of key changes to Life Safety and Fire Protection Systems for CFAA January 22, 2014
2012 OBC Changes Summary of key changes to Life Safety and Fire Protection Systems for CFAA January 22, 2014 2012 OBC New Sentence 3.2.4.2(6) Buildings interconnected by walkways permitted in Articles
More informationChecklist For Life Safety
INSPECTION CHECKLIST Date of Inspection: Location/Address: Weather Condition: Inspector: AFTER COMPLETING YOUR INSPECTION, TRANSFER YOUR CONCERNS/OBSERVATIONS TO THIS AREA Facility: Name: Staff Contact:
More informationCITY OF HOUSTON HIGH-RISE OFFICE BUILDING FIRE SAFETY PLAN
CITY OF HOUSTON HIGH-RISE OFFICE BUILDING FIRE SAFETY PLAN April 15, 2015 DATE Phil Davis PROPERTY MANAGER 2000 West Loop South, Houston, Texas 77027 ADDRESS 713 871 8252 PHONE NUMBER LIFE SAFETY IS THE
More informationBuilding Name: Our Lady of Sorrows Date: July 10, 2013
1 E1. FIRE ALARM SYSTEM ANNUAL TEST AND INSPECTION REPORT (Reference: 5.1.2) Building Name: Our Lady of Sorrows Date: July 10, 2013 Address 19 Mohns Avenue Petawawa, ON System Manufacturer: Siemens Model
More informationUNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1
GENERAL: 1. All fire protection systems shall be installed in accordance with the International Fire Code and applicable NFPA standards. This guideline provides additional requirements for the design and
More informationHousing & Residence Life - Building Emergency Evacuation Plan
9201 University City Blvd, Charlotte, NC 28223-0001 t/ 704.687.1111 f/ 704.687.5302 http://safety.uncc.edu/ Housing & Residence Life - Building Emergency Evacuation Plan This plan establishes fire and
More informationRequirements for Smoke / Carbon Monoxide / Fire Extinguisher Certification
Requirements for Smoke / Carbon Monoxide / Fire Extinguisher Certification In order to successfully pass the inspection, your property will need to meet all regulations mandated by the state and municipality.
More informationINITIAL FIRE SAFETY ASSESSMENT
INITIAL FIRE SAFETY ASSESSMENT Factory Assessor: Plot no. A102, BSCIC Industrial Estate, Tongi, Gazipur Tongi, Gazipur Emkay Enterprises 06 Jul 2014 The Alliance for Bangladesh Worker Safety Page 1/22
More informationCHINO VALLEY INDEPENDENT FIRE DISTRICT FIRE PROTECTION STANDARD
CHINO VALLEY INDEPENDENT FIRE DISTRICT FIRE PROTECTION STANDARD HIGH-RISE REQUIREMENTS STANDARD # 113 REVISED 02/03/1992 PAGES 16 Index Section 1: Section 2: Section 3: Section 4: Section 5: Section 6:
More informationFIRE SAFETY PLAN For Commercial Use
FIRE SAFETY PLAN For Commercial Use Emergency Procedures and Building Safety Maintenance Plan Approved by: Chief Fire Official Date: This official document is to be kept readily available for access in
More informationPLAN REVIEW SUBMITTAL GUIDE
PLAN REVIEW SUBMITTAL GUIDE Plans, specifications and other construction documentation for the initial plan review should be as complete as possible at the time of submittal. Use this convenient guide
More informationOsceola County Department of Fire Rescue and Emergency Medical Services
St. Number Dir Street Name Street Type Inspected Time of Day to be Re-inspected Zip Code Occupancy Type Emergency Contact Phone (Inc. Area Code) Building Owner Building Owner Mailing Address Bldg. Owner
More informationTHE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE
FIRE RISK ASSESSMENT SPORTS CENTRE BUILDING SUMMARY The building is used as a Sports Centre and contains a large sports hall with changing rooms, an office for staff and a fitness area. 1. Identification
More informationItem Referenced and Amendments Building 1 Building 2 Analysis, Review and Remarks. Page 1 of 15
N/A N/A 2015 International Fire Code 2015 International Building Code Codes Jurisdictions for Fire and Building Codes Source of Information Building Fire Plumbing Mechanical Electrical Energy Code Accessibility
More informationFire Safety Plan (Single-Stage Fire Alarm System) (Small Establishment):
Fire Safety Plan (Single-Stage Fire Alarm System) (Small Establishment): Fire Safety Plan Single-Stage Fire Alarm System for: (Business Name) (Business Address) Submission Date - Submitted by - Signature
More informationNYC Department of Education
NYC Department of Education Building Assessment Survey 2017-2018 Asset: P.S. 86 - BROOKLYN, 220 IRVING AVENUE, New York, 11237 Inspection Id Inspection Type Time In Last Edited EE : Electrical 2017-11-14
More informationFire Safety Plan (Single-Stage Fire Alarm System):
Fire Safety Plan (Single-Stage Fire Alarm System): Fire Safety Plan Single-Stage Fire Alarm System for: (Business Name) (Business Address) The reproduction or use of this fire safety plan for non-commercial
More informationFire Safety Plan Two-Stage Fire Alarm System for:
Fire Safety Plan Two-Stage Fire Alarm System for: Fire Safety Plan Two-Stage Fire Alarm System for: (Business Name) (Business Address) Submission Date - Submitted by - Signature The reproduction or use
More informationTABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2
Division 28 ELECTRONIC SAFETY AND SECURITY TABLE OF CONTENTS 28 0000 GENERAL... 2 A. DEFINITIONS...2 28 3111 DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2 A. DESIGN REQUIREMENTS...2 B. CONSTRUCTION REQUIREMENTS...2
More informationMAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS
FIRE CODE BULLETIN December 2004 97 FCB 018 (R1) Page 1 of 5 BACKGROUND: MAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS Fire protection service companies are
More informationFIRE SAFETY PLAN FOR NAME OF BUSINESS (IF APPLICABLE) STREET ADDRESS CITY, PROVINCE POSTAL CODE BUILDING USE # OF UNITS
FIRE SAFETY PLAN FOR NAME OF BUSINESS (IF APPLICABLE) STREET ADDRESS CITY, PROVINCE POSTAL CODE BUILDING USE # OF UNITS PHOTO OF THE FRONT FACE OF THE BUILDING This official document is to be kept on site
More informationSCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL
SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL 3300 SUMMIT BOULEVARD WEST PALM BEACH, FLORIDA 33406 TEL (561) 688-7687 FAX (561) 688-7654 http://www.palmbeach.k12.fl.us/fm/bd/index.htm
More informationAgency for Health Care Administration
Page 1 of 92 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Type Memo Tag FED - K9999 - FINAL OBSERVATIONS Title FINAL OBSERVATIONS Type Memo Tag FED - KA100 - General Requirements - Other Title
More informationBold items are particular to the City of Euless
EULESS FIRE DEPARTMENT FIRE MARSHAL S OFFICE INFORMATION LINE: Revised 8/2004 Fire Chief Lee Koontz Fire Marshal Paul Smith EFD-FMO 3-1 2003 International Fire & Building Code as Amended NFPA Standards
More informationPurpose of Emergency Response Program Emergency Response Team / Leader Evacuation Procedures Building Life Safety System Virtual Evacuation Building
Purpose of Emergency Response Program Emergency Response Team / Leader Evacuation Procedures Building Life Safety System Virtual Evacuation Building Tour Questions and Answers To prepare designated office
More informationFIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT DANNY'S KNITWEAR LTD. ACCORD ID: 12228 SURABARI, GAZIPUR, SADAR, GAZIPUR Other Factories: ne October 17, 2015 Page 2 Fire Safety Inspection Report Introduction manufacturing
More informationA GUIDE FOR CONDUCTING FACILITY PRE-FIRE PLANS
A GUIDE FOR CONDUCTING FACILITY PRE-FIRE PLANS 1. Sketch Each Floor 2. Show Roof access of venting devices 3. Show approaches to the facility 4. Indicate the size of the facility (Length and Width) 5.
More informationNYC Department of Education
Building Assessment Survey 2017-2018 Asset: NEW SCH FOR ARTS AND SCIENCE - X, 965 LONGWOOD AVENUE, New York, 10459 Inspection Id Inspection Type Time In Last Edited EE : Electrical 2017-12-01 8:13 AM 2017-12-01
More information2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.
2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge. Exception: Manual fire alarm boxes are not required where the building is
More information22A Belvedere Avenue, Parry Sound Sprinkler System Consulting Review
Parry Sound District Social Services Administration Board Housing and Community Services October 10, 2018 c/o Andrew Ball, Properties and Capital Projects Coordinator Email:aball@psdssab.org 22A Belvedere
More informationOUTLINE FOR FIRE PREVENTION ACTIVITY
OUTLINE FOR FIRE PREVENTION ACTIVITY Background Buildings under construction present unique fire exposures that require special attention. Fires can result in major losses and long delays in the completion
More informationINFORMATION TO BE INCLUDED IN A FIRE SAFETY PLAN
INFORMATION TO BE INCLUDED IN A FIRE SAFETY PLAN 1 P a g e Completion of Your Fire Safety Plan Once your Fire Safety Plan has been completed you need to send it to the Chief Fire Official for review and
More information12/14/2013. Fire alarm and emergency power SPRINKLER HEAD
Fire alarm and emergency power SPRINKLER HEAD 1 Alert signal Alarm signal Fire detector Heat detector Smoke detector Smoke alarm 1. Detector locations 1. Fire detector locations (3.2.4.11) 2. Smoke detector
More informationFire Safety Plan (Single-Stage Fire Alarm System)
1 Fire Safety Plan (Single-Stage Fire Alarm System) Fire Safety Plan Single or Two-Stage Fire Alarm System for High Buildings: (Business Name) (Business Address) The Halifax Regional Fire & Emergency Service
More informationFIRE SAFETY PLAN FOR RESTAURANT FACILITIES
Insert Picture of Building Address: FIRE SAFETY PLAN FOR RESTAURANT FACILITIES Lock Box Location: Fire Safety Plan Location: Approved: (dd /mm/yyyy) (dd /mm/yyyy) Fire department Building owner Reviewed
More informationFire Safety Plan (Single-Stage Fire Alarm System):
Fire Safety Plan (Single-Stage Fire Alarm System): Fire Safety Plan for building with Single-Stage Fire Alarm System: (Building/Business Name) (Building Address) The reproduction or use of this fire safety
More informationNFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers,
NFPA CODE TESTING & INSPECTION Requirements & Recommendations for Licensed Florida Hospitals, Ambulatory Surgery Centers, ICF/IID Healthcare, & In-patient Hospice Facilities per NFPA Life Safety Code 101
More informationNYC Department of Education
Asset: P.S. 5 - BROOKLYN, 820 HANCOCK STREET, New York, 11233 Inspection Id Inspection Type Time In Last Edited EE : Electrical 2018-05-25 8:54 AM 2018-06-04 10:18 AM Asset Data Type of Service Does Interactive
More informationTHE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE
FIRE RISK ASSESSMENT HORSEFAIR HOUSE BUILDING SUMMARY The building is utilised for the teaching of Science and contains Laboratories and Chemical storage. 1. Identification of the hazards 1.1 Identification
More informationGuidelines to Developing a Fire Safety Plan
Township of Muskoka Lakes Fire Department Guidelines to Developing a Fire Safety Plan Reve Fire Prevention Muskoka Lakes Fire Department 1 Bailey Street, Port Carling 765-3156 COMPOSING A FIRE SAFETY PLAN
More informationOAK GROVE SCHOOL DISTRICT SCHOOL SITE FIRE PREVENTION PLAN
OAK GROVE SCHOOL DISTRICT SCHOOL SITE FIRE PREVENTION PLAN PURPOSE To protect our employees, students, and occupants from the dangers of fire, Oak Grove School District has developed a fire prevention
More informationNY Fire Safety Institute Coordinator of Fire Safety & Alarm Systems F-80
Established 1995 Preparing the future High Rise Building Fire Safety Directors Presents the FDNY Coordinator of Fire Safety and Alarm Systems Homeless Shelters (Premise Related) Certificate of Fitness
More informationFIRE SERVICE FEATURES
CHAPTER 5 FIRE SERVICE FEATURES SECTION 501 GENERAL 501.1 Scope. Fire service features for buildings, structures and premises shall comply with this chapter. 501.2 Permits. A permit shall be required as
More informationEXAMPLE FIRE PREVENTION AND PROTECTION PLAN WORKSHEET
EXAMPLE FIRE PREVENTION AND PROTECTION PLAN WORKSHEET Directions: This worksheet is intended to guide General Contractors through development of a site-specific fire prevention and protection plan meeting
More informationNYC Department of Education
NYC Department of Education Building Assessment Survey 2017-2018 Asset: P.S. 127 - BROOKLYN, 7805 7 AVENUE, New York, 11209 Inspection Id Inspection Type Time In Last Edited EE : Electrical 2017-10-30
More informationWinnipeg Fire Department Fire Prevention Branch
Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of
More informationSt. John s University
St. John s University Fire Safety Plan Mahoney Hall St. John s University Mahoney Hall page 2 Fire Safety Plan Part 1-Building Information Section Mahoney Hall 300 Howard Ave. Staten Island, N.Y. 10301
More informationNirmal Chandra Sinha. Supposed to complete(dd/ MM/YYYY) Comments after Physical Inspection
Factory Name Address Fire Safety Follow up INTIMATE APPARELS LTD Karnaphuli EPZ, Plot no. 91-93, rth Patenga Date 05/20/2014 Date Report Received 11-August/15 Date of 1 st Follow-up 08-vember/15 Date of
More informationEQUIVALENT INITIAL FIRE SAFETY ASSESSMENT
EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT Factory Plot # 33-36 Sector # 07, Chittagong Chittagong Chittagong 08 Jun 2014 The Alliance for Worker Safety Page 1/18 08 Jun 2014 Introduction to the Report
More informationModule 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements
Module 3 Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements 1 WATER-BASED SUPPRESSION SYSTEMS-PART TWO This module covers: 1. Ohio Building Code requirements and when and why
More informationBlack Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment
Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment February 2017 Alberta Fire Code safety equipment maintenance requirements: The Black Diamond Fire Department has
More informationFIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT MULTIFABS LTD KASHIMPUR, NAYAPARA Other Factories: ne April 9, 2014 Page 2 Fire Safety Inspection Report Introduction manufacturing complex was surveyed for fire safety on
More informationINITIAL FIRE SAFETY ASSESSMENT - EXPANSION
INITIAL FIRE SAFETY ASSESSMENT - EXPANSION Factory Mogorkhal, Chowrasta, National University, Gazipur Gazipur Dhaka 09 May 2016 The Alliance for Worker Safety Page 1/13 09 May 2016 Introduction to the
More informationWINNIPEG FIRE PARAMEDIC SERVICE FIRE PREVENTION BRANCH
WINNIPEG FIRE PARAMEDIC SERVICE FIRE PREVENTION BRANCH PREPARATION GUIDELINES FOR FIRE SAFETY PLANS Revised: June/14 1 Table of Contents Introduction 3 General Requirements 4 Preparation Procedures Step
More informationMOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Alarm System Plan Review 2009 International Fire Code and 2010 NFPA 72 Date of Review // BLD201 - Project Address: Project Name: _ Professional
More informationINITIAL FIRE SAFETY ASSESSMENT
INITIAL FIRE SAFETY ASSESSMENT Factory Mouza Chandra, Shafipur, Kaliakoir, Gazipur Gazipur Dhaka 24 Mar 2014 The Alliance for Worker Safety Page 1/12 24 Mar 2014 Introduction to the Report The following
More informationINITIAL FIRE SAFETY ASSESSMENT
INITIAL FIRE SAFETY ASSESSMENT Factory 214 Baiozid Bostami Road Nasirabad Industrial Area Chittagong 04 Sep 2016 The Alliance for Bangladesh Worker Safety Page 1/11 Factory 04 Sep 2016 Introduction to
More informationTHE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS
FIRE RISK ASSESSMENT NEW BUILDINGS BUILDING SUMMARY The building is utilised for classroom teaching for Modern Languages. 1. Identification of the hazards 1.1 Identification of sources of fuel. Timber
More informationFire Safety Plan. (Business Name) (Business Address)
1 Fire Safety Plan (Business Name) (Business Address) (Submission Date) The reproduction or use of this fire safety plan for non-commercial purposes is permitted and encouraged. Permission to reproduce
More informationWhat are the Contents of an Effective Fire Safety Plan? Name: Date: Address of Project: Building Permit Number:
What are the Contents of an Effective Fire Safety Plan? A study of fire safety plans that have already been produced illustrates that one size does not fit all. Depending upon the complexity of a given
More informationBuilding Emergency Policies and Procedures
Building Emergency Policies and Procedures For Van Wormer Hall 2614 Mc Micken Circle Cincinnati, OH 45221 June 2017 University of Cincinnati Department of Public Safety Department Table of Contents A.
More informationAgency for Health Care Administration
Page 1 of 51 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS CFR Type Memo Tag FED - K0130 - MISCELLANEOUS Title MISCELLANEOUS OTHER LSC DEFICIENCY NOT ON 2786 FED - K9999 - FINAL OBSERVATIONS Title
More informationFire Alarm, Water Flow Alarm & Signaling Systems
Orange County Fire Authority Community Risk Reduction 1 Fire Authority Road, Building A, Irvine, CA 92602 www.ocfa.org 714-573-6100 Fire Alarm, Water Flow Alarm & Signaling Systems Guideline D-03 Serving
More informationMECKLENBURG COUNTY FIRE MARSHAL S OFFICE
Effective Date: 11/01/02 Purpose: MECKLENBURG COUNTY To establish a set of guidelines for performance testing of all newly installed or upgraded fire alarm systems in order to ensure that all devices and
More informationFire Sprinkler Plan Submittal Form
Contents Fire Sprinkler Plan Submittal Form... 2 Standpipe Plan Review Submittals... 4 Fire Pump Plan Submittal Requirements... 6 Fire Alarm Plan Submittal Form... 8 Kitchen Hood Wet Chemical Submittal...10
More information