1 REMOTE CONTROL FOR CHILLER MYCHILLER

2 GENERAL FEATURES... 3 MAIN FUNCTIONS AND EQUIPMENT:... 3 LCD DISPLAY... 4 KEYBOARD... 5 BOARD CONFIGURATION... 7 LIST OF MAIN PARAMETERS... 7 CONFIGURATION OF MAIN PARAMETERS... 8 CONFIGURATION OF UNIT... 9 LIST OF UNIT PARAMETERS... 9 CONFIGURATION OF UNIT PARAMETERS... 9 UNIT READINGS DISPLAY READINGS LIST READING DISPLAY PROCEDURE SETPOINT CHANGE TIME BAND CONFIGURATION (ONLY PLUS VERSION) GENERAL OPERATION PROCEDURE FOR ACCESSING TIME BAND PARAMETERS PARAMETER LIST PARAMETERS DEFAULT VALUES DISPLAY OF ACTUAL TIME N.B. FOR REMOTE CONTROL OF UNITS PROVIDED WITH A PCO PROCESSOR WITH THE CLOCK BOARD INSTALLED, MANAGEMENT OF THE TIME BANDS IS ALSO IMPLEMENTED ON THE BOARD SOFTWARE. IF YOU WISH TO MANAGE THE TIME BAND WITH THE REMOTE CONTROL, THIS FEATURE MUST NOT BE ENABLED AT THE SAME TIME ON THE PCO BOARD UNIT ALARMS DISPLAY COMMUNICATION ERROR ALARM CODES N.B. FOR A DETAILED DESCRIPTION OF THE ALARMS, CONSULT THE ELECTRONIC CONTROLLER MANUAL. SERIAL COMMUNICATION CONNECTION TO RS485 COMMUNICATION NETWORK MODBUS LIST OF PCO1/PCOXS SUPERVISION PARAMETERS (MCE TANDEM / MPE TANDEM / MTE / LCE) CIRCUIT BOARD WALL INSTALLATION OF CONTROL TECHNICAL DATA RG Rev.01 2

3 GENERAL FEATURES The chiller remote control was designed to manage cold-only, heat pump and freecooling units through serial communication. The remote control needs to be connected to the unit by means of the connection bus RS485. The remote control can be interfaced with the electronic controllers Carel μchiller2, μchiller2 SE, pco1 and pcoxs by means of the Modbus protocol. MAIN FUNCTIONS AND EQUIPMENT: Switching the unit on/off. Adjustment of temperature setpoint of evaporator infeed water. Changing summer/winter mode (for heat pumps). Displaying and changing main parameters of unit (differentials, minimum and maximum setpoints). Display of advanced parameters (evaporator outfeed water temperature, condensation pressure). Display of alarms active on unit Voltage-free contact for external consent which can enable or disable unit operation Voltage-free contact to enable economy function remotely Built-in clock (only plus version) ON/OFF management and time band Setpoint (only plus version) RG Rev.01 3

4 The control panel includes: LCD display keyboard LCD display L 3 O / N F O F Evaporator infeed water temperature / Serial communication error Room temperature / Alarm Setpoint Unit on Unit off Fan speed (only with pco1 / pcoxs) Operation mode: Cooling. Operation mode: Heating. Defrosting Free Cooling active Alarm present Pump active RG Rev.01 4

5 Compressor active Electrical resistance working Operation with time bands (only plus solo version) Serial communication. The fixed symbol means that the control is in communication with the unit; flashing means there is not connection Backlighting turns on whenever any button is pressed and turns off automatically about 2 minutes after the last key was pressed (only plus version). KEYBOARD ON/OFF key: Switching the unit on/off when changing user parameters, it allows to return to normal operation. the key does not work when the time band ON/OFF (only plus version) or the digital input ON/OFF are active UP and DOWN keys: changes setpoint. used when changing parameters to select the parameters or to change values. When the unit has an alarm, they scroll the active alarm codes SEL key: accesses setpoint change / selection confirmation MODE key: Selection of Heating / Cooling operation mode (only with unit off) VENT key: temporary display of present time (only plus version) ECO key: cancel parameter change RG Rev.01 5

6 Active key combinations Access to parameter configuration procedure Access advanced parameters display Access time band parameters (only plus version) RG Rev.01 6

7 BOARD CONFIGURATION LIST OF MAIN PARAMETERS SERIAL ADDRESS: sets Modbus address (between 1 and 247) of controlled unit TYPE OF PROCESSOR: selects the type of controller present on the unit 0: μchiller2 1: μchiller2 SE 2: pco1/pco XS 3: μchiller2 (for MPE and MCE tandem units, MTE, LCE chiller) 4: μchiller2 (for MPE and MCE tandem units, MTE, LCE heat pump) 5: μchiller2 SE (for MPE tandem, MCE tandem, MTE, LCE chillers) 6: μchiller2 SE (for MPE tandem, MCE tandem, MTE, LCE heat pumps) TYPE OF UNIT: 0: Chiller 1: Heat Pump NUMBER OF CIRCUITS: sets the number of chiller circuits of the unit (1 or 2) DIGITAL INPUT CONFIGURATION: configuration of DIN 1/2 0: DIN1 = - DIN2 = - 1: DIN1 = On/Off DIN2 = - 2: DIN1 = - DIN2 = Eco 3: DIN1 = On/Off DIN2 = Eco If the digital input is not active, time band or keyboard switching on/off would have no effect. If the digital input Economy function is active, the set temperature will be changed to the minimum limit (for heating) or the maximum limit (for cooling). Both can be changed by the unit parameter menu of the remote control (only for models provided with μchiller 2 or μchiller 2 SE), or else directly on the controlled unit. DIN1 LOGIC: 0: [open/closed] = [Off/On] 1: [open/closed] = [On/Off] DIN2 LOGIC: 0: [open/closed] = [-/ECO] 1: [open/closed] = [ECO/-] RG Rev.01 7

8 CONFIGURATION OF MAIN PARAMETERS simultaneously press the keys use the keys to change the value of the display to the value of the password 10, then press. If correct, you can access the parameters use the keys to scroll the various parameters (see Parameter List described above) press to activate the parameter change (the value will flash) use keys to change the value press to save the new value set or to cancel the change once the concerned parameters have been changed, press the key to exit the procedure RG Rev.01 8

9 CONFIGURATION OF UNIT The controlled unit configuration can be changed by accessing a further menu. LIST OF UNIT PARAMETERS SUMMER DIFFERENTIAL WINTER DIFFERENTIAL (only if the type of unit is set at heat pump) MINIMUM SUMMER SETPOINT MAXIMUM SUMMER SETPOINT MINIMUM WINTER SETPOINT (only if the type of unit is set at heat pump) MAXIMUM WINTER SETPOINT (only if the type of unit is set at heat pump) N.B. The pco1/pcoxs control units can only change the differentials CONFIGURATION OF UNIT PARAMETERS simultaneously press the keys use the keys to change the value of the display to the value of the password 30, then RG Rev.01 9

10 press. If correct, you can access the parameters use the keys to scroll the various parameters (see Unit Parameter List described above) press to activate the parameter change (the value will flash) use keys to change the value press to save the new value set or to cancel the change once the concerned parameters have been changed, press the key to exit the procedure RG Rev.01 10

11 UNIT READINGS DISPLAY Allows to display some values read by the controlled unit. READINGS LIST CURRENT SETPOINT (can be changed by compensations set on the unit) EVAPORATOR OUTFEED WATER TEMPERATURE CIRCUIT 1 CONDENSATION PRESSURE CIRCUIT 1 EVAPORATOR OUTFEED WATER TEMPERATURE CIRCUIT 2 (only if the number of circuits is set at 2) CONDENSATION PRESSURE CIRCUIT 2 (only if the number of circuits is set at 2) READING DISPLAY PROCEDURE simultaneously press the keys to access the readings use the keys to scroll the various parameters (see Readings List described above) press the key to return to the initial screen. RG Rev.01 11

12 SETPOINT CHANGE In order to change the evaporator infeed water temperature setpoint, press the key with the control lit (the setpoint will begin to flash) use keys to change the value press the key to store the value. N.B. The set temperature cannot be changed if the time band setpoint management is active or if the remote economy function is active. Should this feature be enabled but not active, the setpoint will continue to be changed with the abovementioned procedure. RG Rev.01 12

13 TIME BAND CONFIGURATION (Only plus version) GENERAL OPERATION Time band configuration is performed by setting the relevant parameters (H parameters) properly and in the correct sequence. Procedure for accessing the parameters and the meaning of each parameter will be described in the following chapters. Two time band operation types can be set: ON/OFF time programming: each time band corresponds to the On or Off status of the control. Therefore, the control turns on or off automatically depending on the time band it is in. This feature has no effect if the digital input On/Off function is enabled. Room temperature SET time programming: each time band is associated with a SUMMER SET temperature (for cooling) and a WINTER SET temperature (for heating). They are used automatically by the control as the Set temperature depending on the time band and operation mode it is in. This feature has no effect if the digital input Economy function is active. Two daily profiles can be defined, each of which is divided into three time bands. One or more profiles can be associated to each day of the week. Daily profile 1: ON/OFF = H12 SET SU ON/OFF = H13 SET SUM = H19 SET WIN = H25 ON/OFF = H14 SET SUM = H20 SET WIN = H26 BAND 1 BAND 2 BAND 3 00:00 Hr1 Hr2 23:59 (H04:H05) (H06:H07) Daily profile 2: SUM = H21 SET WIN = H27 SET BAND 4 BAND 5 BAND 6 00:00 Hr3 Hr4 23:59 (H08:H09) (H10:H11) RG Rev.01 13

14 PROCEDURE FOR ACCESSING TIME BAND PARAMETERS simultaneously press the keys and use the keys to change the value of the display to the value of the password 5, then press. If correct, you can access the parameters press to activate the parameter change (the value will flash) use keys to change the value press to save the new value set or to cancel the change if the value set for H00 is different than 000, use the keys to scroll the various parameters available (see Parameter List ) once the concerned parameters have been changed, press the key to exit the procedure RG Rev.01 14

15 PARAMETER LIST Time band configuration is performed by setting the parameters found one at a time by scrolling with the arrows. Attention: there are 37 parameters on a whole, but not all of them are accessible. Whether some parameters are displayed or not depends on the value assigned to the first parameter (H00), namely based on the type of operation selected. In detail: if H00=1 (ON/OFF mode) the parameters from H18 to H29 are not displayed if H00=2 (SET mode) the parameters from H12 to H17 are not displayed if H00=0 time band mode is disabled and therefore only H00 is displayed The 37 parameters are described hereafter in order: H00 = ENABLING AND OPERATION MODE H00=0 : time bands disabled H00=1 : time bands with ON/OFF H00=2 : time bands with SET temperature CLO: DAY: H01 = HOUR of control clock H02 = MINUTES of control clock H03 = DAY OF THE WEEK Hr1: H04 = HOUR (0-23) of TIME 1 H05 = MINUTES (0-59) of TIME 1 Hr2: H06 = HOUR (0-23) of TIME 2 H07 = MINUTES (0-59) of TIME 2 Hr3: H08 = HOUR (0-23) of TIME 3 H09 = MINUTES (0-59) of TIME 3 Hr4: H10 = HOUR (0-23) of TIME 4 H11 = MINUTES (0-59) of TIME 4 SP1: H12 = STATUS (ON or OFF) of BAND 1 H13 = STATUS (ON or OFF) of BAND 2 H14 = STATUS (ON or OFF) of BAND 3 H15 = STATUS (ON or OFF) of BAND 4 H16 = STATUS (ON or OFF) of BAND 5 H17 = STATUS (ON or OFF) of BAND 6 RG Rev.01 15

16 H18 = SUMMER SET temperature of BAND 1 SP2: H19 = SUMMER SET temperature of BAND 2 SP3: H20 = SUMMER SET temperature of BAND 3 SP4: H21 = SUMMER SET temperature of BAND 4 SP5: H22 = SUMMER SET temperature of BAND 5 SP6: H23 = SUMMER SET temperature of BAND 6 SP1: H24 = WINTER SET temperature of BAND 1 SP2: H25 = WINTER SET temperature of BAND 2 SP3: H26 = WINTER SET temperature of BAND 3 SP4: H27 = WINTER SET temperature of BAND 4 SP5: H28 = WINTER SET temperature of BAND 5 SP6: H29 = WINTER SET temperature of BAND 6 Mon: Tue: Wed: Thu: Fri: Sat: Sun: H30 = daily profile (1 or 2) of MONDAY H31 = daily profile (1 or 2) of TUESDAY H32 = daily profile (1 or 2) of WEDNESDAY H33 = daily profile (1 or 2) of THURSDAY H34 = daily profile (1 or 2) of FRIDAY H35 = daily profile (1 or 2) of SATURDAY H36 = daily profile (1 or 2) of SUNDAY H37 = 24H or 12H display RG Rev.01 16

17 PARAMETERS DEFAULT VALUES H00 = 0 (time bands disabled) Hr1 = 06:00 Hr2 = 22:00 Hr3 = 08:00 Hr4 = 20:00 H12 = OFF H13 = ON H14 = OFF H15 = OFF H16 = ON H17 = OFF H18-H23 = 12 C H24-H29 = 45 C H30-H34 = 1 H35-H36 = 2 H37 = 24H If the 12H display is set (parameter 37), inside the configuration parameters from H01 to H 11 (except H03) the progressive parameter number is not displayed except for the AM/PM time. DISPLAY OF ACTUAL TIME If the time bands are enabled, when the thermostat is on, the clock symbol will always be displayed and the correctness of the set time can be checked (only for a few instants) by pressing the key N.B. For remote control of units provided with a pco processor with the clock board installed, management of the time bands is also implemented on the board software. If you wish to manage the time band with the Remote Control, this feature must not be enabled at the same time on the pco board. RG Rev.01 17

18 UNIT ALARMS DISPLAY Should the controlled unit be in alarm status, the symbol and a flashing error code will appear on the display. This condition will continue until the alarm has terminated or has been deactivated by acting directly on the controller installed on the unit. In order to scroll all the active alarms, use the keys. COMMUNICATION ERROR Should serial communication between the Remote Control and the controlled unit be cut, the display will show an error message accompanied by the corresponding symbol flashing. If communication is restored, the symbol will quit flashing and the evaporator infeed water temperature will return on the display. RG Rev.01 18

19 ALARM CODES μchiller 2 / μchiller 2 SE C1 : Circuit 1 alarm (high pressure / low pressure / circuit breaker / anti-freeze) C2 : Circuit 2 alarm (high pressure / low pressure / circuit breaker / anti-freeze) HP1 : Circuit 1 pressure switch high pressure alarm LP1 : Circuit 1 pressure switch low pressure alarm HP2 : Circuit 2 pressure switch high pressure alarm LP2 : Circuit 2 pressure switch low pressure alarm FLO : Water flow alarm Prb : Probe alarm Hrc : Compressor operation time threshold overcome warning pco1 / pcoxs FLO : Water flow alarm tin : Evaporator infeed water temperature probe alarm to1 : Evaporator outfeed water temperature probe alarm circuit 1 to2 : Evaporator outfeed water temperature probe alarm circuit 2 Pr1 : Condensation pressure probe alarm - circuit 1 Pr2 : Condensation pressure probe alarm - circuit 2 tfc : Freecooling temperature probe alarm AMB : Outdoor temperature probe alarm LP1 : Low pressure alarm - circuit 1 LP2 : Low pressure alarm - circuit 2 HP1 : High pressure alarm - circuit 1 HP2 : High pressure alarm - circuit 2 th1 : Circuit breaker alarm circuit 1 th2 : Circuit breaker alarm circuit 2 RG Rev.01 19

20 Ft1 : Fan circuit breaker alarm bench 1 Ft2 : Fan circuit breaker alarm bench 2 Pt1 : Pump 1 circuit breaker alarm Pt2 : Pump 2 circuit breaker alarm PHS : Phase direction alarm AF1 : Anti-freeze alarm circuit 1 AF2 : Anti-freeze alarm circuit 2 dig : Digital alarm Hrc : Compressor operation time threshold overcome warning N.B. For a detailed description of the alarms, consult the electronic controller manual. RG Rev.01 20

21 SERIAL COMMUNICATION CONNECTION TO RS485 COMMUNICATION NETWORK The Bus communication network is made up of a two-wire shielded cable connected directly to the RS485 serial ports of the remote control (A, B and GND terminals). For the network, use a two-conductor twisted shielded AWG cable with less than 50 pf/m capacity between the wires. For connection with pco1 / pcoxs controllers, a RS 485 serial board is required; for connection with μchiller 2 / μchiller 2 SE controllers, the 485 serial option is required, with key input connection. RG Rev.01 21

22 MODBUS The protocol implemented in the control is Modbus RTU (9600, N, 8, 2) on RS485 IMPLEMENTED FUNCTIONS 0x01: Read Coil Status 0x02: Read Input Status 0x03: Read Holding Registers 0x04: Read Input Registers 0x05: Force Single Coil 0x10: Write Multiple registers IMPLEMENTED EXCEPTIONS Exception Code 02: Invalidate data address LIST OF PCO1/PCOXS SUPERVISION PARAMETERS ADDRESS COIL TYPE 1 Unit status R/W 2 Summer/Winter R/W 31 Compressor 1 R 32 Compressor 2 R 33 Compressor 3 R 34 Compressor 4 R 35 Compressor 5 R 36 Compressor 6 R 37 Compressor 7 R 38 Compressor 8 R 41 Pump 1 R 42 Pump 2 R 43 Bench fans 1 R 44 Bench fans 2 R 45 Resistance R 56 Circuit 1 defrost R 57 Circuit 2 defrost R 62 General alarm R 71 Dig. inputs alarm R 72 Pump 1 circuit breaker alarm R 73 Pump 2 circuit breaker alarm R 74 Flow alarm R 75 Tin probe alarm R 76 Tout1 probe alarm R 77 Tout2 probe alarm R 78 Pcond.1 probe alarm R 79 Pcond.2 probe alarm R 80 Tfc probe alarm R 82 Text probe alarm R 83 Circ.1 LP alarm R 84 Circ.2 LP alarm R 85 Circ.1 HP alarm R RG Rev.01 22

23 86 Circ.2 HP alarm R 91 Circ.1 circuit breaker alarm R 92 Circ.2 circuit breaker alarm R 93 Fan.1 circuit breaker alarm R 94 Fan 2 circuit breaker alarm R 97 Phase direction alarm R 98 Ev. anti-freeze alarm 1 R 99 Ev. anti-freeze alarm 2 R 100 Compr. threshold overcoming 1 R 101 Compr. threshold overcoming 2 R 102 Compr. threshold overcoming 3 R 103 Compr. threshold overcoming 4 R 104 Compr. threshold overcoming 5 R 105 Compr. threshold overcoming 6 R 106 Compr. threshold overcoming 7 R 107 Compr. threshold overcoming 8 R ADDRESS REGISTER TYPE 1 Cond. 1 pressure R 2 Cond. 2 pressure R 3 IN water temp R 4 OUT 1 water temp R 5 OUT 2 water temp R 6 Outdoor temp R 8 Active Setpoint R 13 Minimum summer set R 14 Maximum summer set R 15 Minimum winter set R 16 Maximum winter set R 31 Summer Setpoint R/W 32 Winter Setpoint R/W 33 Summer Differential R/W 34 Winter Differential R/W LIST OF μchiller 2 supervision parameters ADDRESS COIL TYPE 31 Circ. 1 alarm 1 R 32 Circ. 1 alarm 2 R 35 General alarm R RG Rev.01 23

24 36 Probe alarm R 37 Compr. time overcoming R 44 Flow meter alarm R 45 Circ.1 HP alarm R 46 Circ.1 LP alarm R 49 Compressor 1 R/W 50 Resistance 1 R/W 51 Pump R/W 53 Digital alarm R/W 54 Unit status R/W 55 Summer/Winter R/W 58 Circ. 2 HP alarm 2 R 59 Circ. 2 LP alarm 2 R 62 Compressor 2 R/W 63 Resistance 2 R/W ADDRESS REGISTER TYPE 41 Summer Setpoint R/W 42 Summer Differential R/W 43 Winter Setpoint R/W 44 Winter Differential R/W 47 Minimum summer set R/W 48 Maximum summer set R/W 49 Minimum winter set R/W 50 Maximum winter set R/W 70 IN water temp R 71 OUT water temp R 72 Outdoor temp R 73 Cond. pressure R 232 Defrost R LIST OF μchiller 2 SE supervision parameters ADDRESS COIL TYPE 41 Circ. 1 alarm 1 R 42 Circ. 1 alarm 2 R 45 General alarm R 46 Probe alarm R 47 Compr. time overcoming R 54 Flow meter alarm R 55 Circ.1 HP alarm R 56 Circ.1 LP alarm R 59 Compressor 1 R/W 60 Resistance 1 R/W 61 Pump R/W 63 Digital alarm R/W 64 Unit status R/W 65 Summer/Winter R/W 68 Circ. 2 HP alarm 2 R 69 Circ. 2 LP alarm 2 R 72 Compressor 2 R/W 73 Resistance 2 R/W RG Rev.01 24

25 ADDRESS REGISTER TYPE 41 Summer Setpoint R/W 42 Summer Differential R/W 43 Winter Setpoint R/W 44 Winter Differential R/W 47 Minimum summer set R/W 48 Maximum summer set R/W 49 Minimum winter set R/W 50 Maximum winter set R/W 102 IN water temp R 103 OUT water temp R 104 Outdoor temp R 105 Cond. pressure R 341 Defrost R LIST OF μchiller 2 supervision parameters (MCE TANDEM / MPE TANDEM / MTE / LCE) ADDRESS COIL TYPE 31 Circ. 1 alarm 1 R 32 Circ. 1 alarm 2 R 35 General alarm R 36 Probe alarm R 37 Compr. time overcoming R 44 Flow meter alarm R 45 Circ.1 HP alarm R 46 Circ.1 LP alarm R 49 Compressor 1 R/W 50 Resistance 1 R/W 51 Pump R/W 52 Compressor 2 R/W 53 Digital alarm R/W 54 Unit status R/W 55 Summer/Winter R/W 58 Circ. 2 HP alarm 2 R 59 Circ. 2 LP alarm 2 R 62 Compressor 3 R/W 63 Resistance 2 R/W 65 Compressor 4 R/W ADDRESS REGISTER TYPE 41 Summer Setpoint R/W 42 Summer Differential R/W 43 Winter Setpoint R/W 44 Winter Differential R/W 47 Minimum summer set R/W 48 Maximum summer set R/W 49 Minimum winter set R/W 50 Maximum winter set R/W RG Rev.01 25

26 70 IN water temp R 71 OUT water temp R 72 Outdoor temp R 73 Cond. pressure R 232 Defrost R LIST OF μchiller 2 SE supervision parameters (MCE TANDEM / MPE TANDEM / MTE / LCE) ADDRESS COIL TYPE 41 Circ. 1 alarm 1 R 42 Circ. 1 alarm 2 R 45 General alarm R 46 Probe alarm R 47 Compr. time overcoming R 54 Flow meter alarm R 55 Circ.1 HP alarm R 56 Circ.1 LP alarm R 59 Compressor 1 R/W 60 Resistance 1 R/W 61 Pump R/W 62 Compressor 2 R/W 63 Digital alarm R/W 64 Unit status R/W 65 Summer/Winter R/W 68 Circ. 2 HP alarm 2 R 69 Circ. 2 LP alarm 2 R 72 Compressor 3 R/W 73 Resistance 2 R/W 75 Compressor 4 R/W ADDRESS REGISTER TYPE 41 Summer Setpoint R/W 42 Summer Differential R/W 43 Winter Setpoint R/W 44 Winter Differential R/W 47 Minimum summer set R/W 48 Maximum summer set R/W 49 Minimum winter set R/W 50 Maximum winter set R/W 102 IN water temp R 103 OUT water temp R 104 Outdoor temp R 105 Cond. pressure R 341 Defrost R RG Rev.01 26

27 CIRCUIT BOARD S E Where A-B-GND RS 485 N Neutral L Phase PE Earth DI1 Dig.1 input CI12 Common dig.1-2 DI2 Dig.2 input NB: o o o for power connection, use 1 mm 2 section cable for digital inputs, use AWG 24 cables for probe extensions and RS485, use AWG 24 shielded cables RG Rev.01 27

28 WALL INSTALLATION OF CONTROL NB: for wall installation, it is recommended to use an electrical box behind the control to house the wires. NB: before installation, carefully remove the protective film on the display. Film removal may cause dark halos to show up on the display which will disappear in a few seconds and are not a sign of a defect. Instructions for wall installation 1. Remove the control's closing screw. Fig If a 503 electrical enclosure is used, pass the cables through the slot at the bottom of the control and use the holes provided for fastening. Fig. 2 RG Rev.01 28

29 3. Otherwise drill holes in the wall where you would like to install the control, matching the fastening slots (5 x 8 mm) at the bottom of the control. Pass the cables through the slots at the bottom and fix it to the previously drilled holes in the wall with screws. Fig Perform the electrical connections on the terminal board following the relative electrical layout. 5. Close the control fastening the screw removed in point 1. RG Rev.01 29

30 TECHNICAL DATA Power supply Operating temp Storage temp Relay Connectors Digital inputs Vac 50/60Hz Power 8W Protective fuse: 500mA delayed Range 0-50 C Range Normal Open 240V (Resistive) Insulation: coil-contacts distance 8mm 4000V coil-relay dielettric Max room temperature: 105 C 250V 10A Voltage-free contact Closing current 2mA Max closing resistance 50 Ohm RG Rev.01 30

31 NOTES

32 Company UNI EN ISO 9001 and OHSAS certified Bentivoglio (BO) Via Romagnoli 12/a Tel. 051/ Fax. 051/

Index. 1. General description of the application Types of units controlled Types of regulation Condensation...

Index. 1. General description of the application Types of units controlled Types of regulation Condensation... LCS pco ADVANCED MICROPROCESSOR USER MANUAL GB Index 1. General description of the application... 4 1.1. Types of units controlled...4 1.2. Types of regulation...4 1.3. Condensation...4 1.4. Safety devices

More information

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

Modular Standard HP Chiller 1/4 screw compressor with Carel driver Program for pco¹ pco 2 and pcoc Modular Standard HP Chiller 1/4 screw compressor with Carel driver Manual version 1.0 25 September 2003 Program code: FLSTDmMSDE Do we want you to save you time and money?

More information

CONTENTS SAFETY SYMBOLS... 1 GENERAL WARNINGS... 1 MAIN FEATURES... 2 MAIN FUNCTIONS... 2 USER UNIT... 3

CONTENTS SAFETY SYMBOLS... 1 GENERAL WARNINGS... 1 MAIN FEATURES... 2 MAIN FUNCTIONS... 2 USER UNIT... 3 CONTENTS SAFETY SYMBOLS... 1 GENERAL WARNINGS... 1 MAIN FEATURES... 2 MAIN FUNCTIONS... 2 USER UNIT... 3 KEYBOARD...3 ACTIVE KEY COMBINATIONS...4 TURNING THE UNIT ON/OFF...4 CHANGING TEMPERATURE AND FAN

More information

User manual. pco 1 AQUA 4. Polyvalent air cooled heat pump kw AQUA4-CMA-1405-E. lennoxemeia.com

User manual. pco 1 AQUA 4. Polyvalent air cooled heat pump kw AQUA4-CMA-1405-E. lennoxemeia.com User manual pco 1 AQUA 4 Polyvalent air cooled heat pump 50 330 kw AQUA4-CMA-1405-E lennoxemeia.com TABLE OF CONTENTS 1 GENERAL DESCRIPTION OF THE APPLICATION... 2 2 CONTROL LOGIC 2.1 CONTROL OF INLET

More information

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB Summary 1 CONNECTIONS... 3 1.1 TEMPERATURE PROBES...3 1.2 LOW VOLTAGE DIGITAL INPUTS...3 1.3 LIVE DIGITAL INPUTS...4 1.4 RELAY OUTPUTS...5 2 POWER SUPPLY... 6 3 SERIAL CONNECTIONS... 6 4 SOFTWARE... 7

More information

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction. Introduction The UL listed Phone-A-Stat (model # 7632 ) is designed and approved for the safe operation of remotely controlling four independent loads, such as a sprinkler system or a water heater via

More information

Operation manual. Rooftop Packaged Unit

Operation manual. Rooftop Packaged Unit Operation manual Rooftop Packaged Unit odels: UATYQ20ABAY1 UATYQ25ABAY1 UATYQ30ABAY1 UATYQ45ABAY1 UATYQ50ABAY1 UATYQ55ABAY1 UATYQ65ABAY1 UATYQ75ABAY1 UATYQ90ABAY1 UATYQ110ABAY1 UATYQ115ABAY1 UATYQ20AFC2Y1

More information

User Manual Ichill 200 L/D (Firmware version 1.7)

User Manual Ichill 200 L/D (Firmware version 1.7) User Manual Ichill 2 L/D (Firmware version 1.7) Pag. 1 of 142 INDEX 1. GENERAL FEATURES...8 1.1 Main Function... 8 2. ICHILL 2L/D TABLE OF THE FEATURES...1 3. USER INTERFACE...11 4. REMOTE KEYBOARD...15

More information

CONTROLS MANUAL. CARRIERrtc basic & medium electronic control 48/50 EN/EH 50 HB/HF/NZ/NF. Original document

CONTROLS MANUAL. CARRIERrtc basic & medium electronic control 48/50 EN/EH 50 HB/HF/NZ/NF. Original document CONTROLS MANUAL CARRIERrtc basic & medium electronic control 48/50 EN/EH 50 HB/HF/NZ/NF Original document Contents 1. General description....5 2. Set-up... 6 2.1. micropc control board... 6 2.2. TCO user

More information

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button USER MANUAL Type UCG/UDG 57116D 06/12 (MBC) 1.10 2012 OJ Electronics A/S...1 Français...7 Español... 14 Type UCG/UDG Contents Introduction...1 First Time Settings...1 Ground Fault Circuit Interrupter (GFCI)...1

More information

BLAUAIR AUTOMATIC CONTROL SYSTEM

BLAUAIR AUTOMATIC CONTROL SYSTEM BLAUAIR AUTOMATIC CONTROL SYSTEM S30 (KVENT, TH-TUNE) S31 (KVENT) S32 (KVENT, PGDE) EN USER S MANUAL CONTENTS Safety requirements... 3 Purpose... 4 Technical data... 5 Installation and set-up... 6 Control...

More information

Installation, Programming and Operating Guide for Digital, Programmable Thermostat with Smart Fan Technology. with SFT (Smart Fan Technology )

Installation, Programming and Operating Guide for Digital, Programmable Thermostat with Smart Fan Technology. with SFT (Smart Fan Technology ) with SFT (Smart Fan Technology ) Installation, Programming and Operating Guide for Digital, Programmable Thermostat with Smart Fan Technology EclipseEfficiencies.com 2016 Eclipse Efficiencies, Inc. All

More information

AC&R Controller RWR Basic Documentation VR2002 for water to water heat pump units

AC&R Controller RWR Basic Documentation VR2002 for water to water heat pump units AC&R Controller RWR470.10 Basic Documentation VR2002 for water to water heat pump units Table of Contents 1 Summary---------------------------------------------------------------------------------------4

More information

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins Table of Contents Parts Diagram........................................................... 1 Icon Descriptions......................................................... 2 Specifications...........................................................

More information

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE GB TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE 5 kw - 213 kw TABLE OF CONTENTS 1 The series...4 2 Constructive features...4 3 Layout of components...5 4 Models and configurations...13 5 Technical

More information

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB Summary 1 CONNECTIONS... 8 1.1 TEMPERATURE PROBES...8 1.2 PRESSURE PROBES...9 1.3 LOW VOLTAGE DIGITAL INPUTS...10 1.4 LIVE DIGITAL INPUTS...11 1.5 RELAY OUTPUTS...12 2 VOLTAGE/FREQUENCY INPUT...13 3 POWER

More information

SC Installation, Operation & Application Guide

SC Installation, Operation & Application Guide SC 5211 2-Stage Heat Pump Auto Changeover Hardwire Programmable Electronic Thermostat 7-Day, 5-2-Day or 5-1-1-Day Programmable Configurable 2-Stage Heat Pump Systems Large Display With Backlight Selectable

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE MANUAL Prg Sel line alarm on on/off alarm enter Clear EMIpro MICROPROCESSOR CONTENTS 1 GENERAL CHARACTERISTICS Page 2 1.1 General description Page 2 2 EMIPRO USER INTERFACE Page

More information

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422 ºF / º C Rooftop Thermostat Controller Model TRT2422 Description The TRT2422 is a combination controller and thermostat with a built-in scheduler, which is designed for simple and accurate control of single

More information

MO n : 12JMC rév A

MO n : 12JMC rév A CTT8 MO n : rév A Page 2 / 18 MODIFICATIONS Rev. Description Date Checked by Approuved by Z Creation 2012/02/12 JMC LA A First issue 2012/02/14 JMC LA INDEX Page 3 / 18 GENERALITY 4 INTRODUCTION 4 ACCESSORIES

More information

TH232-AF-230 Installation Instructions

TH232-AF-230 Installation Instructions Installation Instructions 230 V Base Parts One (1) thermostat One (1) floor sensor One (1) wall plate Guidelines Turn off power to the heating system at the main power panel to avoid electrical shock.

More information

Safety & Installation Instructions

Safety & Installation Instructions Model 8800 Universal Communicating Thermostat Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS Table of contents Installation Installation location recommendations... 2 Thermostat mounting...

More information

DC 60 & DM 60 displays

DC 60 & DM 60 displays USER MANUAL DC 60 & DM 60 displays BALTIC FLEXAIR ENERGY AIRCOOLAIR COMPACTAIR FLATAIR (& Inverter) AQUALEAN DC60-DM60-IOM-1310-E www.lennoxemea.com Summaries 1 Display DC60 1.1 Introduction... 2 1.2

More information

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort User manual CLIMATIC 2/4 - Controller Providing indoor climate comfort MUL35E-56 9-26 INDEX CONTENTS PAGE INDEX 1 GENERAL DESCRIPTION 2 THE KEYPAD, Climatic 2 3 THE KEYPAD, Climatic 4 4 THE KEYPAD REMOTE

More information

Product Manual SZ1009

Product Manual SZ1009 Product Manual SZ1009 Conventional Heating & Cooling Thermostats with Heat Pump Mode Communicating Thermostats Description The SZ1009 is a microprocessor-based mable thermostats designed for conventional

More information

CTT8 TEMPERATURE MONITOR DEVICE

CTT8 TEMPERATURE MONITOR DEVICE INSTRUCTION MANUAL IM302-U v2.3 CTT8 TEMPERATURE MONITOR DEVICE GENERALITY The device of control temperatures CTT8 is used in the control of electric machine, transformer, motor, etc. where it s possible

More information

EXPERT TRI-STAR. Temperature controller. User s Manual

EXPERT TRI-STAR. Temperature controller. User s Manual Temperature controller r s Manual WARNINGS The warranty can be void if this product is used in a manner not specified by the manufacturer. Every effort has been made to ensure that this manual is complete,

More information

Manual for the integration in BMS/GTC

Manual for the integration in BMS/GTC Manual for the integration in BMS/GTC Communication parameters MODBUS RTU and BACNET COMMUNICATION UTBS PRO-REG Software Version 3.6 EN ÍNDEX 1. GENERALITIES...2 1.1. Introduction...2 1.2. signals types...2

More information

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N DPC-1 Programmable digital thermostat with communication Versión 2.0 Ref: N-27360 1108 Technical Information I S O 9 0 0 1 ER-0028/1991 Johnson Controls Manufacturing España, S.L. is participating in the

More information

Model: Touch-RS. 1 Touch-RS

Model: Touch-RS. 1 Touch-RS Model: Touch-RS Model: Touch-RS 1 Touch-RS Table of Contents Product Image 1 Temperature Hold 15 Table of Contents 2 Holiday Programming 16 What is a Programmable Room Thermostat? Installation Procedure

More information

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL WATER HEATER ELECTRONIC CONTROLLER USER MANUAL UPPER LED READOUT LED ICONS LOWER LED READOUT PVI INDUSTRIES, LLC - Fort Worth, Texas 76111 - Web www.pvi.com - Phone 1-800-433-5654 Page 1 / 7 PV500-40 03/17

More information

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE Emerson Blue Wireless Comfort Interface - Homeowner User Guide Message to Homeowners Congratulations on choosing the Emerson Blue

More information

Service control manual Smart HP. Application FLBB0mHPGU

Service control manual Smart HP. Application FLBB0mHPGU Service control manual Smart HP Application FLBB0mHPGU 1 Summary 1. INTRODUCTION...3 1.1 Purpose of the manual...3 2. SYSTEM ARCHITECTURE...4 2.1 Main control components...4 3. USER INTERFACE...5 3.1 Terminal...5

More information

Standard Chiller Modular HP 1/4 Generic/Bitzer screw compressor and CAREL valve

Standard Chiller Modular HP 1/4 Generic/Bitzer screw compressor and CAREL valve Application program for pco¹ pco² pco 3 Standard Chiller Modular HP 1/4 Generic/Bitzer screw compressor and CAREL valve 1.1 09 / 11 / 2006 version of manual Program code: FLSTDmMSBE We wish to save you

More information

Halton SAFE / 7.14 user guide and installation instructions

Halton SAFE / 7.14 user guide and installation instructions Halton SAFE / 7.14 user guide and installation instructions VERIFIED SOLUTIONS BY H A LTO N Enabling Wellbeing Table of contents 1 System description 3 2 User Accounts 4 3 Main menu 7 3.1 Main menu - Change

More information

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408 997-060180-5 Installation Instructions / User s Manual TSTAT0406 and TSTAT0408 4 HEAT 2 COOL DUAL FUEL TSTAT0406 & TSTAT0408-4 WIRE CAPABLE THERMOSTAT (NAXA00201DB Daughter Board sold separately) LEFT

More information

Refrigerated air dryers

Refrigerated air dryers Refrigerated air dryers OPERATING AND MAINTENANCE MANUAL Original instructions 38178800319 OPERATING AND MAINTENANCE MANUAL - Contents 1 CONTENTS CONTENTS... 1 Chapter 1 IDRY ELECTRONIC CONTROLLER...

More information

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating MAKING MODERN LIVING POSSIBLE TP7001 Range Electronic 7 Day Programmable Room Thermostat Danfoss Heating User Guide TP7001 Electronic 7 Day Programmable Room Thermostat For a large print version of these

More information

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173) Evco S.p.A. Code 104K204E05 page 1/5 EVK204 Digital controller for ventilated refrigerating units, with HACCP and Energy Saving functions version 1.05 GB ENGLISH 1 PREPARATIONS 1.1 Important Please read

More information

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE Release January 2001 CONTENTS 1.0 GENERAL CHARACTERISTICS... 4 1.1 MAIN CHARACTERIS TICS... 4 2.0 USER INTERFACE (CODE C5121230)... 5 2.1 DISPLAY... 5 2.2 MEANING OF THE LEDS...

More information

Smart Temp. Model

Smart Temp. Model Smart Temp Model 42-160 SINGLE STAGE PROGRAMMABLE THERMOSTAT 1 Heat / 1 Cool Single Stage Thermostat. 5+2 Programmable, Compatible with Gas Heat & Heat Pump System Installation and Operation Manual SPECIFICATIONS:--------------------------------------------------------------------------------

More information

DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive

DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive www.devi.com Table of Contents 1. Introduction..................................... 2 2. Technical Specifications.........................

More information

DAP III Zone Master User s Guide

DAP III Zone Master User s Guide DAP III Zone Master User s Guide Data Aire, Inc. 230 West BlueRidge Avenue Orange, California 92865 Document Number 600-000-788 March 2010 Revision 1.0 Document # 600-000-788 1 Overview The Data Aire DAP

More information

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev. TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL Microener- Copyright 2010 FW 2.1 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection

More information

User s guide. Multiple programming Electronic thermostat

User s guide. Multiple programming Electronic thermostat SYSTÈME QUALITÉ CERTIFIÉ - REGISTERED QUALITY SYSTEM User s guide STE402P+ Multiple programming Electronic thermostat Energy Verified For further information or to consult this guide online, please visit

More information

Temperature Controller CC24-7 UNIBOX USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

Temperature Controller CC24-7 UNIBOX USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517) 3 4 Temperature Controller USER S MANUAL Aerotech, Inc. FORM: QM1386 4215 Legion Dr. Mason, MI 48854-1036 USA October 2010 Ph. (517) 676-7070 Fax (517) 676-7078 FOR CUSTOMER USE Enter the serial number

More information

ETN-24-SUPER-PROG (US Program - Celsius)

ETN-24-SUPER-PROG (US Program - Celsius) Meitavtec Ltd (Contel group) Tel: 972 (3) 962 6462 Fax: 972 (3) 962 6620 www.meitavtec.com support@meitavtec.com ETN24SUPERPROG (US Program Celsius) Owner s Manual Installation and Operating Instructions

More information

Product Manual SZ1022/SZ1031/SZ1035/

Product Manual SZ1022/SZ1031/SZ1035/ Product Manual SZ1022/SZ1031/SZ1035/ Conventional Heating & Cooling Thermostats Communicating Thermostats Description The SZ1022, SZ1031, and SZ1035, are microprocessorbased mable thermostats designed

More information

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE Technical features Guide to LCD symbols Guide to keys Technical features Supply by communication bus Number of temperature levels 2 (DAY / NIGHT) Temperature

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS COMFORT CONTROL CENTER 2 THERMOSTAT OPERATING INSTRUCTIONS PROGRAMMABLE THERMOSTAT MODEL 3314080.000 BLACK 3314080.015 WHITE USA SERVICE OFFICE Dometic Corporation 1120 North Main Street Elkhart, IN 46514

More information

T600MEP-2 Programmable Economizer Thermostat

T600MEP-2 Programmable Economizer Thermostat Installation Instructions Issue Date January 19, 2005 T600MEP-2 Programmable Economizer Thermostat Application The T600MEP-2 is a programmable thermostat for control of single- or two-stage unitary rooftop

More information

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135 ERV-24 Technician Settings & Operating Manual Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135 1 Introduction brief description General The ERV-24-HC11

More information

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax: MC200 Users Instructions BSI Registered Firm HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: 01460 53535 Fax: 01460 52341 FM 414 Ind. & Comm. Air Heaters; Air Moving Equipment; Flues & Chimneys;

More information

Products no longer available

Products no longer available Technical data sheet MONICO-.. Turnkey automation station MONICO-.. Forms an efficient fire protection system together with the motorisation sets BF(G)24MP Completely wired controller in matching control

More information

USER MANUAL Comfort System4 TM

USER MANUAL Comfort System4 TM 67023D 07/16 (LOA) OCS4-10 / OSD4-1999 / OSA4-10 USER MANUAL Contents Introduction...1 Central Controller - Menu overview...2 First time settings Setup of the Comfort System4...3 Setup Central Controller...3

More information

USER'S OPERATING INSTRUCTIONS

USER'S OPERATING INSTRUCTIONS SAT-2 Thermostat COOL FAN DRY HEAT AUTO SLEEP SWING AUTO ZONE SUN MON TUE WED THU FRI SAT HEATER ON OFF ERR UNIT USER'S OPERATING INSTRUCTIONS CONTENTS Page Introduction 3 Features Summary 3 Display 4

More information

INSTALLATION & USER MANUAL

INSTALLATION & USER MANUAL INSTALLATION & USER MANUAL HC Digital Automatic Humidistat (Y3760) CONTROLS 506808-01 3/2016 Supersedes 6/2011 picture goes here THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE NOTICE

More information

User manual CLIMATIC 50 - CHILLERS

User manual CLIMATIC 50 - CHILLERS User manual CLIMATIC 50 - CHILLERS Providing indoor climate comfort CL50-CHILLERS-IOM_0808-E INTERNAL USE LENNOX TECHNICIANS VERSION Climatic 50 CHILLER & HEAT PUMP INCLUDING NEOSYS RANGE USER MANUAL Ref:

More information

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF: EC 6-295P220S001 smart guide ON-OFF digital controller for ventilated refrigerating units Version 1.01 of 15 th March 2005 File ec6295p220s001_eng_v1.01.pdf PT EVCO S.r.l. Via Mezzaterra 6, 32036 Sedico

More information

XC1008D -XC1011D- XC1015D and VGC810

XC1008D -XC1011D- XC1015D and VGC810 Electronic Controller for Compressor Racks XC1008D -XC1011D- XC1015D and VGC810 Instructions Manual INDEX 1. GENERAL WARNING 4 1.1 PLEASE READ BEFORE USING THIS MANUAL 4 1.2 SAFETY PRECAUTIONS 4 2. WIRING

More information

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

Table of Contents. SLIMLINE Series MODEL: SLIMLINE Table of Contents Product Image 1 Table of Contents 2 What is a Programmable Room Thermostat? 3-4 Installation Procedure 5-6 LCD Display 7-8 Setting the Clock 9 Temperature Display 10 Setting the Comfort

More information

FPC-02 Series. Installation and Operating manual

FPC-02 Series. Installation and Operating manual Installation and Operating manual Index Introduction.... 3 FPC-02 Installation notes......... 4 Wiring the FPC-02-120V, FPC-02-120V-MDB. 5 Wiring the FPC-02-240V, FPC-02-240V-MDB. 6 Operating instructions.

More information

T-32-TS Touchscreen Thermostat. Installation Manual

T-32-TS Touchscreen Thermostat. Installation Manual T-32-TS Touchscreen Thermostat Installation Manual TABLE OF CONTENTS Introduction...4 Getting Started...5 Installing the Thermostat...6, 8 Disassembly...6 Thermostat Location...6 Mounting the Subbase...6,

More information

Please read this manual carefully before installation and use.

Please read this manual carefully before installation and use. Doylestown, PA 18902 USA Phone: 215-766 1487 - Fax: 215-766 1493 Email: support@scillc.com - www.scillc.com FMT-24-SUPER-PROG With freeze protection Owner s Manual Installation and Operating Instructions

More information

CLEVER CONTROL Version: V3

CLEVER CONTROL Version: V3 CLEVER CONTROL Version: V3 INSTALLATION AND FUNCTIONING MANUAL USER AND BASIC VERSION Please, read these instructions carefully before attempting installation SECURITY ADVISE SIMBOLS Attention, Danger,

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

Elegance. SMT-700 User manual. Ver

Elegance. SMT-700 User manual. Ver Elegance SMT-700 User manual Ver 3.0. 0807 Congratulations on the purchase of your new Thermostat! Your new air conditioning system thermostat has been built using the best components and design philosophy

More information

MCX ELECTRONIC CONTROLLER

MCX ELECTRONIC CONTROLLER WATER - AIR UNITS: CHILLERS y HEAT PUMPS User Manual Thank you for trusting the Hitecsa Products. Our company has been offering the market an extended range of specialized units for air conditioning and

More information

LCF Touch Modbus Datasheet Application Security Advice Caution

LCF Touch Modbus Datasheet Application Security Advice Caution LCF Touch Modbus Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet Subject to technical alteration Issue date: 3.11.214 Application Modern design flush mounting fan coil room

More information

Standard Air Handling Units

Standard Air Handling Units Application software for pco² - pco XS Standard Air Handling Units Program code: FLSTDMAHUA We wish to save you time and money! We can assure you that the thorough reading of this manual will guarantee

More information

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb. Edition 06.14 GB Operating and installation instructions Lago FB digital remote control Translation from the German 2014 Elster GmbH Safety Please read and keep in a safe place Please read through these

More information

Technicians Manual Single Compressor

Technicians Manual Single Compressor Technicians Manual Single Compressor HAC-FF-D WALL PAD Operating Manual Version PCB Version V2.3.5 Version wall pad Version Manual Page 1 Contents 1. Main features 2. Main technical data 3. Wall pad 4.

More information

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1)

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1) SY325 Janfire Pellet Burner Boiler for single / double burner management (Version 1.1) TECHNICAL DATA SHEET V1.1 rev.12/2007 Contents INTRODUCTION...3 1 THE CONTROL PANEL...4 2 THE KEYS...4 3 THE LEDS...4

More information

SC Installation, Operation & Application Guide

SC Installation, Operation & Application Guide SC 5811 2 Heat/2 Cool Auto Changeover Hardwire Programmable Electronic Thermostat 7-Day, 5-2-Day or 5-1-1-Day Programmable Configurable 2-Stage Heat/2-Stage Cool Systems 2-Stage Heat Pump Systems Large

More information

EVF818 Installer manual ver. 1.0 Code 144F818E104 EVF818. Split execution controller for temperaturecontrolled

EVF818 Installer manual ver. 1.0 Code 144F818E104 EVF818. Split execution controller for temperaturecontrolled EVF818 Split execution controller for temperaturecontrolled blast chillers (with capacitive touch-key user interface, which can be integrated into the unit) ENGLISH INSTALLER MANUAL ver. 1.0 CODE 144F818E104

More information

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252 AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252 USER OPERATION AND MAINTENANCE WARNING Risk of electrical shock. Can cause severe injury, property damage or death. Only

More information

Evolution Control. Zone Control Homeowner s Guide

Evolution Control. Zone Control Homeowner s Guide Evolution Control Zone Control Homeowner s Guide CONGRATULATIONS! Your decision to choose the Bryant Evolution Control puts you in a select group of homeowners who understand the value of precise comfort

More information

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort USER MANUAL S203 Controller for three circuits - control for 2 heating circuits - 1 domestic hot water control Saving energy, creating comfort This user manual consists of two parts. Issues that are intended

More information

MCX ELECTRONIC CONTROLLER

MCX ELECTRONIC CONTROLLER WATER - AIR UNITS: CHILLERS y HEAT PUMPS Installer Manual Thank you for trusting the Hitecsa Products. Our company has been offering the market an extended range of specialized units for air conditioning

More information

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS HP727S Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS 1. General Description 2. Specifications 3. Installation Instructions 4. Electrical Wiring 5. Instrument Wiring

More information

irad Wireless Controller

irad Wireless Controller irad Wireless Controller The irad Wireless Controller is a wireless (433MHz) programmable thermostat giving high precision room temperature control. It also had a seven day programmer with up to six temperature

More information

User Guide for EHE & EHE Programmable Room Thermostat

User Guide for EHE & EHE Programmable Room Thermostat User Guide for EHE0200153 & EHE0200154 Programmable Room Thermostat Description The EHE0200153 & EHE0200154 are programmable room thermostats designed to control your heating system efficiently, providing

More information

5-stage compressor racks + 2 converter outputs

5-stage compressor racks + 2 converter outputs GB 1454H502 Ed.02 AKO-14545 AKO-14545-C 5-stage compressor racks + 2 converter outputs User Manual Contents Page 1.- Precautions...3 2.- Versions and part numbers...3 3.- Description...3 3.1.- Keypad functions...3

More information

User Manual THR870CUK Programmable Thermostat

User Manual THR870CUK Programmable Thermostat User Manual UK Programmable Thermostat 50051984-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 20-31). If you are not experienced in wiring electrical

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication Description The TFHB24F3XYZ1 is a fully configurable controller designed specifically for 2 pipe and 4 pipe fan coil applications.

More information

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY USER GUIDE RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification

More information

Air-condensed water cooling units and heat pumps YLCA / YLHA PLUS 5 to 27

Air-condensed water cooling units and heat pumps YLCA / YLHA PLUS 5 to 27 ir-condensed water cooling units and heat pumps YLC / YLH PLUS 5 to 27 User manual Ref.: N-40315_EN 1110 Index Index 1 User manual...1 1.1 General description of the unit...2 1.1.1 Models available and

More information

Basic Plus2 Room Thermostats Floor Heating

Basic Plus2 Room Thermostats Floor Heating MAKING MODERN LIVING POSSIBLE User Guide Basic Plus2 Room Thermostats Floor Heating www.heating.danfoss.com The English language is used for the original instructions. Other languages are a translation

More information

Digital Thermostat Models: VS30W and VS30B

Digital Thermostat Models: VS30W and VS30B it600 VS30W - VS30B Installer - User Manual 015_Layout 1 28.07.2014 10:28 Digital Thermostat Models: VS30W and VS30B INSTALLER / USER MANUAL it600 VS30W - VS30B Installer - User Manual 015_Layout 1 28.07.2014

More information

/18 (JRK) MTD User Manual OJ Electronics A/S

/18 (JRK) MTD User Manual OJ Electronics A/S 67772 02/18 (JRK) MTD3-1999 User Manual Table of Contents Introduction.................................. 3 Menu Overview................................ 4 Icons....................................... 5

More information

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time Operating instructions Page 14 Refrigerator Read the operating instructions before switching on for the first time 7084 309-00 LKUv Disposal notes The appliance contains reusable materials and should be

More information

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL 1. INTROUCTION Zone control is a two pieces fan coil thermostat available for Heat/Cool versions. Its application is for the duct type system

More information

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control Ocean Breeze 2951 SE Dominica Terrace, Stuart, Florida 34997 Tel: 772 2200038 obr@oceanbreezeac.com http://www.oceanbreezeac.com

More information

SC Installation, Operation & Application Guide

SC Installation, Operation & Application Guide SC 3006 Auto Changeover 7-Day Programmable Hardwired Programmable Electronic Thermostat 7-Day Programmable Single Stage Heat Pump/Non-Heat Pump Systems Backlit Display Single Stage Heat/Cool Systems Field

More information

GreenCon On/Off Room Thermostat

GreenCon On/Off Room Thermostat Description Features: Scandinavian design with white backlight; User-friendly interactive interface; Room temperature display and settings; 12 or 24 hour clock display and settings; Three-speed manual/automatic

More information

GreenCon On/Off Room Thermostat

GreenCon On/Off Room Thermostat Description Features: Scandinavian design with white backlight; User-friendly interactive interface; Room temperature display and settings; 12 or 24 hour clock display and settings; Three-speed manual/automatic

More information

IPC108D - IPC108E (V.2.0)

IPC108D - IPC108E (V.2.0) IPC108D - IPC108E (V.2.0) APPLICATION GUIDE INDEX 1. IMPORTANT RECOMMENDATIONS 6 1.1 PRODUCT DISPOSAL (WEEE) 7 2. GENERALITIES 8 3. AVAILABLE APPLICATION CONFIGURATIONS 8 3.1 MAIN FUNCTIONS 9 4. SUPERVISION

More information

T7351 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS

T7351 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS T7351 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS 63-2652 FEATURES Typically used in buildings (including: restaurants, shopping malls, office buildings and banks) under 55,000 square feet.

More information