Intrusion. Control Panels

Size: px
Start display at page:

Download "Intrusion. Control Panels"

Transcription

1 Intrusion Control Panels

2 Work-scope of SLC Distribution Europe, Africa & Middle East. As a division of Interlogix Europe & Africa, SLC Distribution offers a full range of security products for sale through professional security distributors. The product range of SLC Distribution comprises of products from the following well-known security brand names belonging to the Interlogix group: CADDX: Intrusion control panels and glass break sensors Sentrol: Magnetic contacts, glass break sensors and PIR detectors Becuwe: Magnetic contacts ESL: Fire detectors Cosmotron: Seismic detectors and glass break sensors GBC: Covert miniature cameras and video transmission systems For over 20 years CADDX has been a leader in providing sophisticated yet simple-to-use products for the security industry. Combining innovative design engineering with the most advanced manufacturing techniques have made CADDX one of the leading manufacturers of electronic security equipment. The CADDX product range comprises the NetworX control panel family as well as the Solution glass break sensors. SLC Distribution is a division of 2 SLC DISTRIBUTION

3 The NetworX Series contents Introduction page 2 Control panels page 3 Keypads page 11 Auxiliary modules page 15 Wireless page 21 Control panels - accessories page 25 Demo equipment page 28 Glass break detection page 29 3 SLC DISTRIBUTION

4 The NetworX Series control panels A complete range of control panels for residential and commercial applications commercial residential NetworX burglar and fire alarm hardwire & wireless The NetworX series: general features ❺ ❺ ❺ ❺ ❺ ❺ ❺ ❺ unique distributed intelligence architecture allows low cost entry-level product capable of expanding and growing as technology shifts. upgrade path - often new technology can be added without modification to existing panels and modules. world wide field proven state of the art core design unique NetworX bus with excellent noise immunity no fuses, automatic reset breaker design. advanced lightning protection. built-in siren driver or voltage siren output. 4 SLC DISTRIBUTION

5 The NetworX Series control panels A complete range of control panels for residential and commercial applications NX-8E zones hardwire/wireless control panel NX zones hardwire/wireless control panel NX zones hardwire/wireless control panel NX zones hardwire/wireless control panel The NetworX series offers you the following advantages : ❺ one product line that does it all ❺ can be used on most installations, yet simple enough to learn only once ❺ convenient: program all panels (from 4 to 192 zones) the same way ❺ flexible: install multiple modules in one enclosure ❺ expandable: add zones quickly and cost-effectively ❺ reliable: leading-edge wireless technology provides optimal performance ❺ scalable: configure system easily to meet your customer's needs ❺ keeps inventory lean: all NX products are universally compatible ❺ slash training time: all NX panels program the same way, from zones ❺ a complete range of control panels for residential and commercial applications 5 SLC DISTRIBUTION

6 control panels The NetworX family : comparison table Features NX-4 NX-6 NX-8 NX-8E Number of on-board zones Max. number of zones Max. number of hardwire / wireless zones 4 / 8 6 / / / 192 Max. number of user codes digit / 6 digit user codes 8/8 40/40 99/66 240/180 Number of partitions 1 (non partitionable) 2 (incl. common zones) 8 8 Max. events in event log Number of on-board open collectors Number of on-board relays (1SPDT/ 1NO) (optional) 2 (1 NC/1 NO) OC/relay outputs supervised (250 ma) Yes Yes No Yes Up/downloadable (Windows) Yes Yes Yes Yes Max. number of modules 1 (excl. keypads) 3 (excl. keypads) 32 (max. 24 keypads) 32 (max. 32 keypads) Max. number of keypads (LCD/LED) 8 8 per partition, max per partition, max per partition, max wire smoke detection No Yes (aux 4) Yes (zone 8) Yes (zone 8; L37,S6) Fire alarm verification Yes Yes Yes Yes Auxiliary power supply on-board 1 A (35 VA) 1 A (35 VA) 1 A (35 VA) 2A (40 VA) Max. auxiliary power supply 3 A (1 x NX-320) 7 A(3 x NX-320) 9 A(4 x NX-320) 10 A(4 x NX320) NetworX compatible Yes Yes Yes Yes Telephone line monitoring (voltage / current ) No Yes Yes Yes Configuration groups Battery switch-off (< 9.5 Volt) No Yes Yes Yes Battery supervision Yes Yes Yes Yes Dynamic battery test Yes Yes Yes Yes Max. battery to install 4 Ah (7 Ah) 7 Ah (17 Ah) 7 Ah (17 Ah) 7 Ah (17 Ah) Can types 1 X-pand-A can (small) Final set door Yes Yes Yes Yes Summer / wintertime Yes Yes Yes Yes Early open/late to close No No No Yes On-board RS-232 No No No Yes Integrated home automation protocol No No No Yes, via RS-232 Zone activity monitoring No No No Yes Automatic disarm enable No No No Yes TBR21 approved Yes Yes Yes Yes Number of telephone numbers Call-back number Yes Yes Yes Yes Unattended up/downloading Yes Yes Yes Yes Contact ID format Yes Yes Yes Yes SIA format Yes Yes Yes Yes 4+2 format Yes Yes Yes Yes Siren tone format Yes Yes Yes Yes Customizable formats Yes Yes Yes Yes 2-way voice (optional via NX-534) Yes Yes Yes Yes Voice (to be done) Yes Yes Yes Yes X-10 compatible Yes Yes Yes Yes Zone doubling or 2R configuration Yes Yes Yes Yes 6 SLC DISTRIBUTION

7 NX-4: NetworX 4-8 zone control panel control panels ❺ 4 fully programmable zones ❺ wireless expansion up to 8 zones ❺ hardwire/wireless hybrid ❺ all zones programmable as fire or burglary ❺ 20 customizable pre-configured zone types ❺ 8 user code (4 or 6 digits) ❺ 1 duress code ❺ up/downloadable with competitor lockout ❺ modular design with slide in PC boards NX zones hardwire/wireless control panel ❺ mini X-Pand-A-Can metal enclosure with "tool tray" ❺ fuseless design Battery is optional ❺ 2 programmable on-board open collector outputs ❺ max. 8 keypads ❺ swinger shutdown ❺ walk test mode ❺ siren supervision ❺ force arm by zone ❺ automatic arming with auto retry ❺ fire alarm verificationi ❺ answering machine defeat ❺ built-in siren driver/voltage output ❺ dynamic battery test ❺ events reportable to max. 3 phone numbers ❺ 185 event log ❺ zone doubling or double E.O.L. configuration (depending on country version) Sophisticated security with an economic appeal. The NX-4 brings sophisticated security with an economical appeal to the NetworX family of control/communicators. Capable of supporting virtually any of the powerful expander modules* from the NetworX family, the NX-4 expands the universe of options available to the smaller system user. Wireless expansion, two-way voice and home automation with X-10 are just a few of the available expansion options for this powerful, low-cost control panel. *Maximum, one module per control panel Supply voltage (typical) 230 Vac, +- 10% 50 Hz Operating power (nominal) 16.5 Vac/50Hz 25 VA Current consumption min. 66 ma Battery max. 12 V / 7 Ah Auxiliary power 500 ma with 25 VA transformer 1 A with 35 VA transformer On-board siren driver 112 db, 2 tones (steady/yelp) Operating temperature 0 to 50 C Enclosure dimensions 235 x 212 x 92 (w x h x d) Weight 2.32 kg (incl. transformer and tamp- NXC401 NX-4-LXT 4 to 8 zone control panel, in enclosure, without cam lock, transformer and tamper NXC402 NX-4-LX 4 to 8 zone control panel, in enclosure, without cam lock and transformer, with tamper NXC403 NX-4 4 to 8 zone control panel, in enclosure, without cam lock, with transformer and tamper When ordering control panels, please refer to the price list for correct ordering codes and part numbers. 7 SLC DISTRIBUTION

8 NX-6: NetworX 6-16 zone control panel control panels ❺ 6 fully programmable zones ❺ wireless expansion up to 16 zones ❺ hardwire/wireless hybrid ❺ all zones programmable as fire or burglary ❺ 2 true partitions ❺ 20 customizable pre-configured zone types ❺ 40 user codes (4 or 6 digits) ❺ 1 duress code ❺ up/downloadable with competitor lockout NX zones hardwire/wireless control panel ❺ modular design with slide in PC boards ❺ X-Pand-A-Can metal enclosure with "tool tray" Battery is optional ❺ fuseless design ❺ 4 programmable on-board open collector outputs ❺ maximum 16 keypads per system ( 8 per partition) ❺ swinger shutdown ❺ walk test mode ❺ siren supervision ❺ force arm by zone ❺ automatic arming with auto retry ❺ fire alarm verification ❺ 2-wire or 4-wire smoke detectors ❺ answering machine defeat ❺ built-in siren driver/voltage output ❺ dynamic battery test ❺ voltage and current telephone line monitor Flexible expansion capabilities for mid-size installations. With available add-on modules to accommodate enhancements such as wireless integration, X-10 home automation and two-way voice, the NX-6 provides flexible expansion capabilities for mid-size installations. These multiple systems modules* will slide into the X-Pand-A-Can metal enclosure, with up-front terminal placement and corresponding wire channels for efficient access to all modules. *Maximum, three modules per control panel Supply voltage (typical) 230 Vac, +- 10% 50 Hz Operating power (nominal) 16.5 Vac/50 Hz 25 VA Current consumption min. 70 ma Battery max. 12 V / 17 Ah Auxiliary power 500 ma with 25 VA transformer 1 A with 35 VA transformer On-board siren driver 112 db, 2 tones (steady/yelp) Operating temperature 0 to 50 C Enclosure dimensions 290 x 290 x 95 mm (w x h x d) Weight 3.02 kg (incl. transformer and tamper) ❺ events reportable to max. 3 phone numbers ❺ 185 event log ❺ zone doubling or double E.O.L. configuration (depending on country version) NXC601 NX-6-LXT 6 to 16 zone control panel, in enclosure, without transformer, tamper and with cam lock NXC602 NX-6-LX 6 to 16 zone control panel, in enclosure, without transformer, with tamper and cam lock NXC603 NX-6 6 to 16 zone control panel, in enclosure, with transformer, tamper and cam lock. When ordering control panels, please refer to the price list for correct ordering codes and part numbers. 8 SLC DISTRIBUTION

9 NX-8: NetworX 8-48 zone control panel control panels ❺ 8 fully programmable zones, expandable to 48 hardwired zones ❺ wireless expansion up to 48 zones ❺ hardwire/wireless hybrid ❺ all zones programmable as fire or burglary ❺ 8 true partitions ❺ 20 customizable pre-configured zone types ❺ 99 four digit or 66 six digit user codes ❺ 1 duress code ❺ up/downloadable with competitor lockout ❺ modular design with slide in PC boards ❺ X-Pand-A-Can metal enclosure with tool tray ❺ Optional commercial enclosure for large installations ❺ fuseless design ❺ 4 programmable on-board open collector outputs ❺ 2 optional programmable relays possible (1 SPDT/1 NO) ❺ maximum 24 keypads per system (8 per partition) ❺ swinger shutdown ❺ walk test mode ❺ siren supervision ❺ force arm by zone ❺ automatic arming with auto retry ❺ fire alarm verification ❺ 2-wire or 4-wire smoke detectors ❺ answering machine defeat ❺ built-in siren driver/voltage output ❺ dynamic battery test ❺ voltage and current telephone line monitor ❺ events reportable to max. 3 phone numbers ❺ 185 event log ❺ zone doubling or double E.O.L. configuration (depending on country version) 9 SLC DISTRIBUTION NX zones hardwire/wireless control panel The fexible system, easily programmable and yet powerful enough to use on most installations. The installer friendly X-Pand-A-Can metal enclosure allows a complete integration of multiple systems modules* within one enclosure. The up-front terminal placement and corresponding wire channels assure efficient access to all modules at all times. Adding more zones or expanded capability is fast, easy and usually will not require additional wall space or the extra expense of added enclosures. *Maximum, 32 modules per control panel Supply voltage (typical) 230 Vac, +- 10% 50 Hz Operating power (nominal) 16.5 Vac/50 Hz 25 VA Current consumption Battery Auxiliary power On-board siren driver min. 60 ma max. 12 V / 17 Ah Operating temperature 0 to 50 C NXC801 NX-8-LXTR 8 to 48 zone control panel, in enclosure without transformer, tamper, relays and with cam lock NXC802 NX-8-LXR 8 to 48 zone control panel, in enclosure without transformer and relays, with tamper and cam lock NXC803 NX-8-LX 8 to 48 zone control panel, in enclosure without transformer, with tamper, relays and cam lock NXC804 NX-8 8 to 48 zone control panel, in enclosure with transformer, tamper, relays and cam lock. NXC805 NX-8-CB-LXTR 8 to 48 zone control panel, in commercial enclosure, including stand-offs without transformer, tamper, relays and with cam lock NXC806 NX-8-CB-LXR 8 to 48 zone control panel, in commercial enclosure, including stand-offs, without transformer and relays, with tamper and cam lock NXC807 NX-8-CB- LX 8 to 48 zone control panel, in commercial enclosure, including stand-offs, without transformer, with tamper, relays and cam lock NXC808 NX-8-CB 8 to 48 zone control panel, in commercial enclosure, including stand-offs, with transformer, tamper, relays and cam lock When ordering control panels, please refer to the price list for correct ordering codes and part numbers. 500 ma with 25 VA transformer 1 A with 35 VA transformer 112 db, 2 tones (steady/yelp) Enclosure dimensions 290 x 290 x 95 mm (w x h x d) Weight (small enclosure) Weight (big enclosure) Battery is optional small enclosure 385 x 460 x 119 mm (w x h x d) commercial enclosure 3.1 kg (incl. transformer and tamper) 8.6 kg (incl. transformer and tamper & stand-offs)

10 NX-8E: NetworX zone control panel control panels ❺ 8 fully programmable zones, expandable to 192 hard-wired zones ❺ wireless expansion up to 192 zones ❺ hardwire/wireless hybrid ❺ all zones programmable as fire or burglary ❺ 8 true partitions ❺ 20 customizable pre-configured zone types ❺ 240 four digit or 180 six digit user codes ❺ 1 duress code ❺ up/downloadable with competitor lockout ❺ modular design with slide in PC boards ❺ X-Pand-A-Can metal enclosure with tool tray ❺ Optional commercial enclosure for large installations ❺ fuseless design ❺ 4 programmable on-board open collector outputs ❺ 2 programmable relays (1 NC/1 NO) ❺ on board RS232 interface for PC/printer connection ❺ maximum 32 keypads per system (8 per partition) ❺ swinger shutdown ❺ walk test mode ❺ siren supervision ❺ force arm by zone ❺ automatic arming with auto retry ❺ fire alarm verification ❺ 2-wire or 4-wire smoke detectors ❺ answering machine defeat ❺ built-in siren driver/voltage output ❺ dynamic battery test ❺ voltage and current telephone line monitor ❺ events reportable to max. 3 phone numbers ❺ 512 event log ❺ zone doubling or double E.O.L. configuration (depending on country version) NX-8E zones hardwire/wireless control panel The most convenient, flexible, durable and user-friendly control panel ever seen. Featuring sophisticated software which allows up to 240 users to interface with 192 zones and 8 partitions. The NetworX design allows a fully loaded system to be housed in one single metal enclosure, establishing a logical solution and design response to modular systems. Up to 32 modules can be added to expand the capabilities of the NX8-E. Supply voltage (typical) 230 Vac, +- 10% 50 Hz Operating power (nominal) 16.5 Vac / 50 Hz 40 VA Current consumption Battery Auxiliary power On-board siren driver Operating temperature min. 60 ma max. 12 V / 17 Ah 2 A with 40 VA transformer 112 db, 2 tones (steady/yelp) 0 to 50 C Enclosure dimensions 290 x 290 x 95 mm (w x h x d) Weight (small enclosure) Weight (big enclosure) Battery is optional small enclosure 385 x 460 x 119 mm (w x h x d) commercial enclosure 3.9 kg (incl. transformer and tamper) 8.6 kg (incl. transformer and tamper & stand-offs) NXC810 NX-8E-LXT 8 to 192 zone control panel, in enclosure, without transformer, tamper and with cam lock NXC811 NX-8E-LX 8 to 192 zone control panel, in enclosure, without transformer, with tamper and cam lock NXC812 NX-8E 8 to 192 zone control panel, in enclosure, with transformer, tamper, relays and cam lock. NXC813 NX-8E-CB-LXT 8 to 192 zone control panel, in commercial enclosure, including stand-offs, without transformer and tamper, with cam lock NXC814 NX-8E-CB-LX 8 to 192 zone control panel, in commercial enclosure,including stand-offs, without transformer, with tamper and cam lock NXC815 NX-8E-CB 8 to 192 zone control panel, in commercial enclosure, including stand-offs, with transformer, tamper and cam lock. When ordering control panels, please refer to the price list for correct ordering codes and part numbers. 10 SLC DISTRIBUTION

11 General features keypads ❺ up to 24 keypads per system ❺ up to 8 keypads per partition ❺ maximum keypad distance from control panel: 800 m ❺ backlit keys with audible feedback ❺ armed, ready, fire and power LED ❺ independently adjustable keypad tones ❺ independently silence keypad tones ❺ unique ding dong chime feature ❺ three hold-down emergency keys for fire, panic and medical alarm ❺ audible exit delay countdown ❺ silent exit arming mode ❺ full keypad supervision ❺ five function keys for simplified operation (stay, chime, exit, bypass, cancel) ❺ cancel alarm button with visual indication ❺ one button quick arm (stay or away mode) selectable by partition ❺ programmable duress code ❺ alarm memory feature ❺ manual system test for dynamic battery test and/or siren test and/or communicator test ❺ reset smoke detectors ❺ set system date and time ❺ download callback enable ❺ service indication for system diagnostics ❺ tamper switch for protection against opening and removal ❺ display of date/time and custom message (2 lines): only on LCD keypads. NX-100 series NX-1300 series NX-1500 series All NetworX control panels can be operated and are fully programmable from any of the NetworX keypads. There are a variety of keypads available. Thanks to their special design (with 5 function keys and numerous status LEDs), all keypads are easy to operate. The 5 special function keys simplify the most commonly required functions. The keypads are equipped with screw terminals, allowing an easy connection. For best comfort, an LCD keypad is the right choice because its display shows customized zone texts. The following system troubles can be displayed on all keypads, as well as communicated to the central station ( if so programmed): ❺ AC power failure ❺ Low battery ❺ Power fault (overcurrent) ❺ Siren trouble ❺ Box tamper ❺ Expander power failure (with NX-320 power supply) ❺ Expander low battery ❺ Expander box tamper ❺ Expander trouble ❺ Expander overcurrent ❺ Zone tamper ❺ Zone low battery (wireless) ❺ Zone loss of supervision (wireless) ❺ Zone trouble ❺ Telephone line cut/trouble ❺ Failure to communicate ❺ Loss of system time 11 SLC DISTRIBUTION NX-148

12 NX-108/116/124 : 8 / 16 / 24 zone LED keypad keypads NX-108 NX-116 ❺ backlit keys and full annunciation of system status ❺ 5 special function keys for simplified operation ❺ 3 keypad activated emergency alarms (fire, medical, panic) ❺ full keypad supervision ❺ global or partition operation ❺ compatible with all NetworX panels NX-124 Operating power (nominal) 12 Vdc via NetworX bus Current consumption - min. (quiescent, no lighting) 10 ma - max. (alarm) 90, 110, 130 ma (8, 16, 24 LEDs) Operating temperature 0 to 50 C Dimensions 163 x 102 x 26 mm (w x h x d) Weight kg NXK001 NX zone LED keypad, without door NXK002 NX zone LED keypad, without door NXK003 NX zone LED keypad, without door 12 SLC DISTRIBUTION When ordering keypads, please refer to the price list for correct ordering codes and part numbers.

13 NX-1308/1316/1324 : 8 / 16 / 24 zone LED design keypad with removable door keypads NX-1308 NX-1308 with door opened NX-1316 ❺ backlit keys and full annunciation of system status ❺ 5 special function keys for simplified operation NX-1324 ❺ 3 keypad activated emergency alarms (fire, medical, panic) ❺ full keypad supervision ❺ global or partition operation NX-1316 with door removed ❺ design keypad with removable door ❺ compatible with all NetworX panels Operating power (nominal) 12 Vdc via NetworX bus Current consumption - min. (quiescent, no lighting) 10 ma - max. (alarm) 90, 110, 130 ma (8,16,24 LEDs) Operating temperature 0 to 50 C Dimensions 158 x 135 x 30 mm (w x h x d) Weight kg NXK004 NX zone LED design keypad with removable door NXK005 NX zone LED design keypad with removable door NXK006 NX zone LED design keypad with removable door 13 SLC DISTRIBUTION When ordering keypads, please refer to the price list for correct ordering codes and part numbers.

14 NX : 8-16 zone vertical LED keypad with removable door keypads NX-1508 with door removed ❺ backlit keys and full annunciation of system status ❺ 5 special function keys for simplified operation NX-1516 ❺ 3 keypad activated emergency alarms (fire, medical, panic) ❺ full keypad supervision NX-1508 ❺ global or partition operation ❺ vertical LED keypad with removable door ❺ compatible with all NetworX panels NX-1508 with door opened Operating power (nominal) 12 Vdc via NetworX bus Current consumption - min. (quiescent, no lighting) 10 ma - max. (alarm) 90, 110 ma (8,16 led s) Operating temperature 0 to 50 C Dimensions 76 x 145 x 30mm (w x h x d) Weight kg NXK007 NX zone vertical LED keypad with removable door NXK008 NX zone vertical LED keypad with removable door 14 SLC DISTRIBUTION When ordering keypads, always add language code (for label). For more details, please refer to the price list.

15 NX-148 : LCD design keypad with removable door keypads NX-148 with door closed ❺ Large 2x16 character LCD display ❺ Adjustable backlit display and full annunciation of system status ❺ 5 special function keys for simplified operation ❺ 3 keypad activated emergency alarms (fire, medical, panic) NX-148 with door removed ❺ full keypad supervision ❺ global or partition operation ❺ design keypad with removable door ❺ menu driven operation ❺ language toggle function (choice between 2 languages) ❺ compatible with all NetworX panels NX-148 with door opened Operating power (nominal) 12 Vdc via NetworX bus Current consumption - min. (quiescent, no lighting) 20 ma - max. (alarm) 110 ma Operating temperature 0 to 50 C Dimensions 158 x 135 x 30 mm (w x h x d) Weight kg 15 SLC DISTRIBUTION NXK009 NX-148 LCD design keypad, with removable door When ordering keypads, please refer to the price list for correct ordering codes and part numbers.

16 NX zone expander module for NX-8 NX-216E - 16 zone expander module for NX-8E auxiliary modules ❺ expansion by 8 or 16 zones (max. 5 modules) ❺ remotely locatable: can be installed up to 800 m from the control panel ❺ box tamper input ❺ equipped with a power isolator The NX-216 is a microprocessor-controlled 16-zone expander for the NX-8 control panel. Up to five NX-216 expanders can be added to the NetworX control panel with a maximum zone count of 48 zones. The NX-216 can be slided into the control panel enclosure or can be installed remotely. NX-216 Operating power (nominal) 12 Vdc via NetworX bus Current consumption (typical) 34 ma Auxiliary power output 12 Vdc/ 100 ma Tamper input NC contact Operating temperature 0 to 50 C Dimensions PC board 153 x 54 mm Weight PC board kg NXM001 NX zone expander module for NX-8 When ordering expanders modules, please refer to the price list for correct ordering codes and part numbers ❺ expansion by 8 or 16 zones (max. 23 modules) ❺ remotely locatable: can be installed up to 800 m from the control panel ❺ box tamper input ❺ equipped with a power isolator The NX-216E is a microprocessor-controlled 16-zone expander for the NX-8E control panel. Up to twenty-three NX-216E expanders can be added to the NX-8E control panel with a maximum zone count of 192 zones. The NX-216E can be slided into the control panel enclosure or can be installed remotely. NX-216 E Operating power (nominal) 12 Vdc via NetworX bus Current consumption (typical) 34 ma Auxiliary power output 12 Vdc/ 100 ma Tamper input NC contact Operating temperature 0 to 50 C Dimensions PC board 153 x 54 mm Weight PC board kg 16 SLC DISTRIBUTION NXM004 NX-216E 16 zone expander module for NX-8E When ordering expanders modules, please refer to the price list for correct ordering codes and part numbers

17 NX-508 output module with 8 open collectors NX-507 output module with 7 relays auxiliary modules ❺ 8 open collectors, max. 100 ma ❺ remotely locatable, can be mounted up to 800 m from the control panel ❺ max. eight NX-508 modules per system (64 outputs in total) ❺ X-10 compatible ❺ Parallel printer output ❺ Box tamper input ❺ Separate auxiliary power supervision ❺ Auxiliary power output of 100 ma ❺ 8 programmable schedules NX-508 The NX-508 is a microprocessor-controlled output module with 8 programmable open collector outputs. The module has an X-10 interface for light control and home automation purposes. This module also includes a parallel printer output to allow for local hard copy reporting of all significant events. Operating power (nominal) Current consumption - minimum (no outputs enabled) 10 ma - maximum (all outputs enabled) 25 ma Auxiliary power output Printer output Tamper input 12 Vdc via NetworX bus 12 Vdc/100 ma parallel NC contact Operating temperature 0 to 50 C Dimensions PC board Weight PC board 153 x 54 mm kg NXM007 NX-508 output module with 8 open collectors When ordering output modules, please refer to the price list for correct ordering codes and part numbers ❺ 7 programmable relay outputs and 1 open collectors ❺ remotely locatable, can be mounted up to 800 m from the control panel ❺ max. eight NX-507 modules per system (64 outputs in total) ❺ X-10 compatible ❺ Box tamper input ❺ Separate auxiliary power supervision ❺ Auxiliary power output of 100 ma ❺ 8 programmable schedules The NX-507 is a microprocessor-controlled output module with 7 programmable relay outputs and 1 additional open collector output. The module has also an X-10 interface for light control and home automation purposes Operating power (nominal) 12 Vdc via NetworX bus Current consumption - minimum (no outputs enabled) 10 ma - maximum (all outputs enabled) 25 ma Auxiliary power output 12 Vdc/100 ma Programmable outputs - Programmable relays 7 (SPDT) - Programmable open collector 1 - total current 100 ma Tamper input NC contact Operating temperature 0 to 50 C Dimensions PC board 153 x 54 mm Weight PC board kg NX SLC DISTRIBUTION NXM011 NX-507 Output module with 7 relays and 1 open collector When ordering output modules, please refer to the price list for correct ordering codes and part numbers

18 NX-320 smart power supply and bus extender auxiliary modules ❺ 2 amp continuous power supply ❺ remotely locatable, can be mounted up to 800 m from the control panel ❺ extends the bus range with 800 m up to 1600 m NX-320 ❺ two stage battery charging ❺ low battery disconnect ❺ isolation and buffering of data bus ❺ three 1.5 amp switched outputs ❺ 2.0 amp fully supervised bell output ❺ all outputs short circuit protected ❺ box tamper input When the job is too large for a conventional control panel, the NX-320 expands the options of the NetworX control panel. The NX-320 smart power supply can provide up to 2 amps of additional 12 volt auxiliary power. Its modular, slide-in design permits mounting inside the enclosure together with the main control or remotely up to 800 m away. This module also allows the bus circuit to be extended an additional 800 m for a total distance of 1600 m for larger buildings, or satellite buildings located a distance away from the main building. Power supply (typical) Operating power (nominal) Current consumption (typical) Battery Power outputs Tamper input Bell output 230 Vac, +-10% / 50 Hz 16.5 Vac/50 Hz / 40 VA min. 10 ma 12V/17Ah three, total 2 A nom. (max 1.5 A/ output) NC contact 2 A max. Operating temperature 0 to 50 C Dimensions PC board Weight PC board 153 x 54 mm kg NXM014 NX-320 Smart power supply and bus extender 18 SLC DISTRIBUTION

19 Miniature NX-534 Two-way outdoor ball voice camera module magnetic auxiliary modules contacts NX-534 ❺ line hold or call back mode ❺ call-in mode ❺ listen-in and talk mode ❺ speaker lockout when a duress signal is sent to central station ❺ 2 microphone inputs, separately selectable for the connection of max. 4 microphones ❺ 1 speaker output ❺ equipped with X-10 interface to control max. 9 X-10 devices 3510 The NX-534 is a two-way audio (voice) module that may be added to a new or existing NetworX control panel. Once the alarm panel has communicated an alarm, the NX-534 will allow a monitoring service operator the ability to monitor a customer s premises for listen-in purposes or basic two-way voice communication. This procedure is controlled from the central station by use of a touch tone telephone. A unique call-in mode permits the user to place a telephone call to listen-in to the audible conditions within the areas of protection. Other features include a call-back mode, high gain/low gain modes, line hold mode and speaker lockout. The NX-534 provides a cost effective approach to high quality audio performance NX Two way voice module Operating power (nominal) 12 Vdc via NetworX bus Current consumption - stand-by 50 ma - in session 100 ma Line modes line hold/call-back Audio modes listen-in/talk (half duplex) Microphone inputs 2 (selectable) Speaker output 1 (5 Watt, 8 Ohm) X-10 interface control max. 9 x 10 devices Optional accessories 3510 (speaker/microphone unit) 3520 (additional microphone) Operating temperature 0 to 50 C Dimensions PC board 54 x 152 x 18 mm Weight PC board kg 3510 Loudspeaker/microphone unit for NX-534 Dimensions 110x110x55 mm Weight kg 3520 Additional microphone for NX-534 Dimension (dia x H) 9 x 7 mm Weight kg ordering code part number full product description 19 SLC DISTRIBUTION NXM015 NX-534 Two-way voice module NXM Loudspeaker/microphone unit for NX-534 NXM Additional microphone for NX-534 When ordering two-way voice modules, please refer to the price list for correct ordering codes and part numbers

20 NX-540 Telephone interface module auxiliary modules ❺ local or remote access ❺ controlling max. 32 X-10 outputs with programmable description ❺ remotely locatable, can be mounted up to 800 m from the control panel Voice interface and system control via local or remote telephone access becomes very easy with the integrated NX-540. Controlling the alarm system with up to 32 X-10 outputs becomes as simple as dialing the operator. NX-540 Operating power (nominal) 12 Vdc via NetworX bus Current consumption - stand-by 55 ma - in session 130 ma Relay output SPDT (30 V/1 A) Open collector outputs 2, max. 100 ma Operating temperature 0 to 50 C Dimensions PC board 153 x 81 mm Weight PC board kg NXM020 NX-540 Telephone interface module 20 SLC DISTRIBUTION

21 NX Home automation module NX Direct connect interface auxiliary modules ❺ several programmable security levels determine how much information is passed to the host system ❺ possibility to limit the number of commands accepted from the host system ❺ easily configurable for communication in ASCII or Binary protocol ❺ selectable baud rate ❺ fast response because information of selectable events/conditions is sent to host without polling NX-584 The NX-584 is a low cost add-on module that fits neatly into any NetworX family system enclosure and provides a standard RS-232 bi-directional DB-9 connector for connection to a home automation host system. A simple threewire connection to the main control is all that is required to fully integrate this card into the system. Operating power (nominal) Current consumption (typical) Communication protocol Baud rate 12 Vdc via NetworX bus 30 ma ASCII or Binary programmable from 600 baud to 76.8k baud Operating temperature 0 to 50 C Dimensions PC board Weight PC board with RTS and CTS handshaking 112 x 81 mm 0.06 kg NXM021 NX-584 home automation module ❺ allows on-site programming of direct connection ❺ compatible with all NetworX panels NX-586 Interface for on-site programming, no need for a telephone line and modem, direct connection to any NetworX panel Operating power (nominal) 12 Vdc via NetworX bus Dimensions 96 x 42 x 22 mm (w x d x h) Weight (including bus cable) kg NXM022 NX-586 Direct connect interface 21 SLC DISTRIBUTION

22 NX-408-I/NX-416-I/NX-448-I : wireless receivers wireless ❺ add wireless capabilities to NetworX panels ❺ compatible with all NX wireless transmitters ❺ MHz ❺ up to 8 (NX-4), 16 (NX-6) or 192 (NX-8E) supervised wireless zones ❺ mixture of hardwired and wireless zones possible ❺ keypad annunciation of alarm, tamper, low battery and lost transmitter ❺ optional tamper switch ❺ optional jam detection ❺ optional antenna tamper detection ❺ choice between 3 models: - NX-408-I : 8 transmitters - NX-416-I : 16 transmitters - NX-448-I : 48 transmitters NX-408-I / NX-416-I / NX-448- I These wireless receivers allow the integration of the most advanced wireless technology with the NetworX panels. Depending on the control panel that is used, up to 8, 16, 48 or 192 transmitters can be individually displayed at the keypad for alarm and all supervisory reports. Due to its modular design, the receivers can be mounted in the control panel enclosure or they can be installed remotely in a separate receiver enclosure NX-469. Operating power (nominal) Power consumption Frequency 12 Vdc via NetworX bus max. 20 ma 433,92 MHz Operating temperature 0 to 50 C Dimensions PC board Weight NX x 81 mm (excluding antennas) kg 22 SLC DISTRIBUTION NXW001 NX-408-I 8 zone wireless receiver, MHz NXW002 NX-416-I 16 zone wireless receiver, MHz NXW003 NX-448-I 48 zone wireless receiver, MHz NXW004 NX-469 Wireless receiver enclosure

23 NX-450-I/NX-451-I : door/window transmitters NX-480-I : Wireless PIR motion detector wireless ❺ installs on anything that opens or closes ❺ 2 internal reed switches allow for vertical or horizontal mounting ❺ supervised: sends a supervisory signal to receiver every 64 minutes ❺ input for NO or NC external switch (disable both read switches) ❺ tamper switch ❺ compatible with NX-408-I, NX-416-I and NX-448-I receivers ❺ color: off-white (NX-450-I) or brown (NX-451-I) NX-450-I NX-451-I The door/window transmitters can be installed on doors, windows or virtually anything that opens and closes. During normal application, the sensor transmits open (trip) and close (restore) signals to the control panel receiver. The sensor also sends a supervisory signal every 64 minutes. Power source Battery life (typical) Transmit range 3. 6 Volt lithium battery 5-8 years 150 m (open air) Interval supervisory signal transmission : 64 minutes Input Tamper switch Operating temperature Color housing NO or NC for external switch NC 0 to 50 C - NX-450-I off-white - NX-451-I brown Dimensions - contact 82 x 39 x 24 mm - magnet 40 x 11 x 13 mm Weight kg (including magnet and battery) NXW005 NX-450-I Door/window transmitter, MHz, off-white NXW006 NX-451-I Door/window transmitter, MHz, brown ❺ compatible with NX-408-I, NX-416-I and NX-448-I receivers ❺ passive infrared detector: 11 x 12 m ❺ 3-minute transmitter lock out time after an alarm (extends battery life) ❺ special walk test mode after tamper activation (60 sec.) ❺ tamper switch (opening/removal) ❺ optional pet lens NX-485 ❺ supervisory signal transmitted every 64 minutes ❺ standard/high sensitivity setting NX-480-I NX-485 The wireless PIR motion detector can be used to provide an extra margin of safety. Without the need for wires, it can be placed where ever it is not practical to install door/window sensors on every opening. Power source Battery life (typical) Transmit range two 1.5 Vdc AA alkaline batteries 3-4 years 150 m (open air) Interval supervisory signal transmission : 64 minutes Range PIR Sensitivity setting Power safe features: 11 x 12 m 2 levels (standard/high) - Transmitter lock out time 3 minutes after an alarm - Special walk test mode 60 sec (after tamper activation) Tamper switch Operating temperature 0 to 50 C Dimensions Weight Color housing detection of opening and removal 73 x 62 x 59 mm 0,128 kg (incl. batteries) off-white 23 SLC DISTRIBUTION NXW007 NX-480-I Wireless PIR motion detector, MHz NXW008 NX-485 Pet alley lens for NX-480-I (5 pack)

24 NX-470-I : four-button key fob NX-475-I : Pendant panic sensor wireless ❺ compatible with NX-408-I, NX-416-I and NX-448-I receivers ❺ not supervised ❺ functions possible: arm/disarm, arm in stay/instant mode, exit function, panic and medical alarm, activate output NX-470-I The four-button key fob provides users with convenient options for arming the system (with or without entry delay), disarming the system and activating panic and medical alarm as well as activating outputs Power source Battery life (typical) Transmit range 12V, 33 mah alkaline battery 5-8 years 150 m (open air) Operating temperature 0 to 50 C Dimensions Weight Color housing 58 x 36 x 11 mm kg (incl. battery) black NXW009 NX-470-I Four-button key fob, MHz ❺ compatible with NX-408-I, NX-416-I and NX-448-I receivers ❺ not supervised ❺ water and shock resistant ❺ recessed panic button prevents false alarms ❺ can be worn around the neck ❺ built-in belt clip allows sensor to be attached to belt or purse ❺ allows to activate a 24-hour emergency alarm ( police, medical or auxiliary alarm) NX-475-I The water-resistant panic sensor can be used throughout the premises for police, medical or auxiliary alarm activation. The water-resistant design helps to prevent damage in case the sensor accidentally gets wet. Power source Battery life (typical) Transmit range 3.5 Vdc lithium battery 5-8 years 150 m (open air) Operating temperature 0 to 50 C Dimensions Weight Color housing 72 x 44 x 28 mm kg (incl. battery) off-white NXW010 NX-475-I Water-resistant pendant panic sensor, MHz 24 SLC DISTRIBUTION

25 NX-491-I : Wireless smoke detector with self diagnostic wireless ❺ compatible with NX-408-I, NX-416-I and NX-448-I receivers ❺ photo-electric smoke detector with built-in piezo sounder and status LED (normal / alarm / trouble condition) ❺ supervisory signal transmitted every 64 minutes ❺ equipped with test / silence button ❺ field replaceable optical chamber ❺ Built-in drift compensation reduces false alarms ❺ low current draw increases battery life The NX-491-I is a wireless photo-electric smoke sensor with a built-in sensitivity meter monitoring continually its own operational status and provides a visual trouble condition if it drifts out of the sensitivity range or fails internal diagnostics. The alarm sensitivity level can be determined at the alarm without a meter. Built-in drift compensation, usually only available in analog systems, allows the alarm to adjust automatically its sensitivity over NX-491-I time as it becomes dirty. This feature dramatically increases the time between cleanings and reduces false alarms. A built-in 85 db temporal sounder is ideal for residential installations and other occupancies where people are sleeping. Once a day and immediately upon the first power up, the alarm performs a full diagnostic test that includes a dynamic test of the sensing chamber and internal electronics. Voltage 3 Vdc (two lithium batteries) Transmit range 150 m (open air) Interval supervisory signal transmission : 64 minutes Operating humidity 0-95% non condensing Sounder 85 db Color housing white Operating temperature 4.4 to 38 C Dimensions 140 x 58 mm Weight 0.3 kg (including batteries) NXW012 NX-491-I Wireless smoke detector, MHz 25 SLC DISTRIBUTION

26 Control panel PC boards accessories NX-4-BO-FG NX-6-BO-FG NX-8-BO-FG All PC boards come with 2 card slides and with sufficient resistors. For technical details: please refer to corresponding control panel data. Mecanical specifications (PC Boards only) Part number Dimensions Weight NX-4-B0-FG 223 x 90 x kg NX-6-B0-FG 280 x 90 x kg NX-8-B0-FG 280 x 90 x kg NX-8E-B0-FG 280 x 90 x kg NX-8E-BO-FG 26 SLC DISTRIBUTION NXA001 NX-4-BO-FG NX-4 PC board only NXA002 NX-6-BO-FG NX-6 PC board only NXA003 NX-8-BO-LR-FG NX-8 PC board only NXA004 NX-8-BO-FG NX-8 PC board only, including relays NXA005 NX-8E-BO-FG NX-8E PC board only When ordering control panel PC boards, please refer to the price list for correct ordering codes and part numbers

27 Enclosures and accessories accessories NX-002 NX-003CB (tamper switch is optional) 600-CL There is a choice between 3 different enclosure types. Depending on the enclosure type, a cam lock or stand-off rails may be included. Please refer to the table underneath for more technical data. Tamper switches and cam locks can be ordered separately, as well as card slides. NX-003 NX-005-C NX-005 NX CA SL NX-002 NX-003 NX-003C NX-003CB Compatibility NX-4 NX-6/8/8E NX-8/8E NX-8/8E Cam lock No Yes Yes Yes Tamper switch No No No No Stand-off rails No No No Yes Dimensions (mm) 212 x 235 x x 290 x x 395 x x 395 x 130 Weight (kg) (excl. rails) 27 SLC DISTRIBUTION NXA010 NX-002 Mini X-Pand-A-Can metal enclosure (for NX-4), no cam lock, no tamper NXA011 NX-003 X-Pand-A-Can metal enclosure (for NX-6/8/8E), with cam lock, no tamper NXA012 NX-003C Commercial metal enclosure (for NX-8/NX-8E), with cam lock, no tamper NXA013 NX-003CB Commercial metal enclosure (for NX-8/NX-8E), with cam lock, no tamper and including stand-offs NXA014 NX-005 Tamper switch with metal bracket for NX-002/003 NXA015 NX-005-C Tamper switch for commercial enclosure for NX-003C / CB NXA CL Cam lock with 2 keys NXA017 NX-CA-SL Set of 2 card slides including screws

28 Transformers Accessories There is a choice of a 35VA and 40VA transformer. Both transformers are CE compliant and come with a fuse terminal block. Please refer to the table below for further technical data Compatibility NX-4/6/8 NX-8E/NX-320 Power 35VA 40VA Fuse terminal block included Yes Yes CE-compliant Yes Yes Dimensions (mm) 86 x 45 x x 45 x 80 Weight (kg) 0.75 kg 0.75 kg NXA Transformer 35VA for NX-4/6/8 NXA Transformer 40VA for NX-8E/NX SLC DISTRIBUTION

29 Demo Equipment demo equipment BC-300 with optional NX-148-CC BC-300 with optional NX-108-CC NX-108-CC NX-124-CC NX-1308-CC NX-1316-CC NX-1324-CC NX-148-CC The BC-300 briefcase demo helps you enhancing your sales presentations and trainings. The BC-300 consists of a briefcase with an NX-8 PC board built-in. The briefcase demo has all necessary RJ-11 plug inputs for connection of keypads and modem. The demo-case is fully operational and enables detailed demons-trations on operating the system. There is a choice of different keypads, equipped with a coil cord to simplify connections. 29 SLC DISTRIBUTION NXD001 BC-300 Briefcase demo with NX-8 board, no keypads included NXD002 NX-108-CC 8 zone LED keypad without door, with coil cord NXD003 NX-124-CC 24 zone LED keypad without door, with coil cord NXD004 NX-1308-CC 8 zone LED design keypad with removable door, with coil cord NXD005 NX-1316-CC 16 zone LED design keypad with removable door, with coil cord NXD006 NX-1324-CC 24 zone LED design keypad with removable door, with coil cord NXD007 NX-148-CC LCD design keypad with removable door, with coil cord When ordering keypads, please refer to the price list for correct ordering codes and part numbers.

30 Glass break detection glass break detection 2200 GT-2 ❺ unique and advanced 3x3 technology ❺ microprocessor based ❺ automatic adjustment ❺ detects all glass types ❺ power/status LED The Caddx glass break sensors make use of the most advanced method of glass break detection, called 3x3 technology. This technology monitors three specific frequency ranges (low, mid, high) for three different sets of data (peak amplitude, signal duration and ambient average), looking for a match to the signature of breaking glass. The glass break sensors have a timeless styling so that they fit into any décor. ❺ alarm memory LED ❺ push button test mode ❺ ceiling or wall mount Power supply Power consumption Alarm output Tamper output Alarm indication Sensitivity adjustment Detection range Operating temperature Dimensions Weight Color housing 9 15 Vdc 15 ma (9 ma in alarm) 100 Vdc, 120 ma 30 Vdc, 50 ma red LED automatic max. 8.5 m radius -10 to +55 C 55.8 x 94 x 22.5 mm kg White CGB Audio glass break detector CGB010 GT-2 Glass break tester 30 SLC DISTRIBUTION

31

32 SLC Distribution a division of Interlogix Europe & Africa Excelsiorlaan, 28 - B-1930 Zaventem Tel : Fax :

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...

More information

P Zone Expandable Hybrid Security System

P Zone Expandable Hybrid Security System Page 1 of 11 up to 8 hardwired keypads and 4 wireless keypads 4 hardwired keypads available with zone input PWLS910 wireless handheld keypad added wireless control is provided by - PWLS908 wireless panic

More information

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION... 2 2. STANDARD AND OPTIONAL PARTS LIST... 2 3. FEATURE DEFINITIONS... 3 4. TERMINAL DRAWING AND SPECIAL

More information

Control/Communicator Installation Manual

Control/Communicator Installation Manual DAS NETWORX NX-12 Control/Communicator Installation Manual General Description...2 Ordering Information...2 Option Definitions...3 Programming the LED Code Pads...5 Programming the NX-12...9 Types of Programming

More information

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. TABLE OF CONTENTS... P.1 2. GENERAL DESCRIPTION... P.2... 3. STANDARD AND OPTIONAL PARTS LIST... P.2... 4. FEATURE

More information

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup NetworX Series NX-8 Commercial Fire Panel Installation and Startup 2004 GE Security All rights reserved. Printed in the United States of America. These instructions do not purport to cover all details

More information

DS7400Xi Addressable Control/ Communicator

DS7400Xi Addressable Control/ Communicator DS7400Xi Addressable Control/ Communicator DS7400Xi DS7400Xi-EXP 110VAC operation 220VAC operation Remotely Programmable WDSRP (Windows Detection Systems Remote Programming Software), allows the systems

More information

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION...P.2 2. STANDARD AND OPTIONAL PARTS LIST...P.2 3. FEATURE DEFINITIONS...P.3 4. TERMINAL DRAWING AND

More information

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E... 5$1*(5( DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS General Description... 2 Standard and Optional Parts List... 2 Feature Definitions... 3 Comments about the 8600E... 4 Terminal

More information

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION...2 STANDARD AND OPTIONAL PARTS LIST...2 FEATURE DEFINITIONS...3 TERMINAL DRAWING AND SPECIAL NOTES...4

More information

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 XL-2G Gold Product Overview 7 Zones (6 programmable + panic or keyswitch zone) Fast Loop Response

More information

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS Feature Charts Control Panels FEATURE CHART LYNX Plus (L3000) (Supported Feature) (Not Supported) N/A (Not Applicable) LYNX Touch (L5210)

More information

Addressable Fire Alarm Control Panel

Addressable Fire Alarm Control Panel PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT

More information

PRODUCT CATALOG. Concord Family Product Catalog. December 1999

PRODUCT CATALOG. Concord Family Product Catalog. December 1999 PRODUCT CATALOG Concord Family Product Catalog December 1999 Interactive Technologies, Inc. 2266 Second Street North, North Saint Paul, MN 55109 800/777-5484 www.itii.com CONTROL PANELS Concord Express

More information

Series. NX-4-EUR Control Panel. Installation manual

Series. NX-4-EUR Control Panel. Installation manual g GE Security NetworX TM Series NX-4-EUR Control Panel Installation manual CONTENTS CONTENTS...2 GENERAL INFORMATION...4 ORDERING INFORMATION...4 FEATURE DEFINITIONS...5 PROGRAMMING THE NX-4 KEYPADS...12

More information

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160 All-In-One Wireless Security System V3.2 Programming Guide Model # MG6130 / MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

ERS-3600B. PERS-3600B Personal Emergency Reporting System

ERS-3600B. PERS-3600B Personal Emergency Reporting System PERS-3600B Personal Emergency Reporting System ERS-3600B A Complete Emergency System For Comprehensive Care The Linear PERS-3600B includes a built-in speakerphone and reminder message capability, providing

More information

Installation Instructions

Installation Instructions NX-148E-RF LCD Touchpad with Receiver 466-2198C February 2006 Copyright 2006, GE Security Inc. Contents Product summary 1 Installation 1 Transmitter programming 2 Touchpad programming 5 Reference tables

More information

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1 1.1 PC5015 Specifications System Introduction S E C T I O N 1 Flexible Zone Configuration: 8 Fully Programmable Zones 38 Access Codes: 32 User, 1 System Master, 2 Partition Master, 2 Duress and 1 maintenance

More information

WIRELESS CONTROLS & DETECTORS

WIRELESS CONTROLS & DETECTORS WIRELESS CONTROLS & DETECTORS WLS908 Panic Pendant Press 2 buttons for 2 seconds to initiate a panic alarm Water-resistant Pendant test function Supervised for low battery Each pendant is a wireless zone

More information

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging 1.1 Specifications System Introduction S E C T I O N 1 Control Panel Specifications Flexible Zone Configuration: 8 Fully Programmable Zones 38 Access Codes: 32 User, 1 System Master, 2 Partition Master,

More information

security timeless design innovative products inspired technology

security timeless design innovative products inspired technology security issue one spring 2011 DAS resource catalogue Product Highlight: // VOICENAV LITE PAGE 6 timeless design innovative products inspired technology CONTENTS Leading supplier of electronic security,

More information

NetworX Series NX-4V2 Control Panel Installation and Startup

NetworX Series NX-4V2 Control Panel Installation and Startup NetworX Series NX-4V2 Control Panel Installation and Startup 2005 GE Security All rights reserved. These instructions do not purport to cover all details or variations in equipment nor to provide every

More information

EVO192 v3.0 Fire and Burglary What s New

EVO192 v3.0 Fire and Burglary What s New EVO192 v3.0 Fire and Burglary What s New Compatibility: EVO192 v3.0 TM50 v1.31 K641 v2.41 Overview: CP-01 Compliancy Wiring Diagram The following sections/options have been added to the EVO192 panel. They

More information

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED... ALARM... CONTROL..... PANELS... AND... KEYPADS....- WIRED........ Securi-Prod 4 Zone Perimeter Alarm 4 x EOL zone alarm panel 2K2 Zone EOL resistance value Multiple Arm/Disarm functions Built in receiver

More information

TABLE OF CONTENTS TABLE OF CONTENTS 1

TABLE OF CONTENTS TABLE OF CONTENTS 1 TABLE OF CONTENTS TABLE OF CONTENTS 1 FEATURES 2 Keypad Programmable... 2 EEPROM Memory... 2 Static/Lightning Protection... 2 Supervision... 2 Operation... 2 SPECIFICATIONS 2 PC1550 Control Panel... 2

More information

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide Digiplex System V2.14 / V2.2ACC Control Panel Programming Guide Table of Contents Getting Started...2 What Do I Do First?...2 How Do I Program the Control Panel?...2 Single Digit Entry Method...2 Multiple

More information

NetworX Series NX-6 CONTROL PANEL. Installation and Startup

NetworX Series NX-6 CONTROL PANEL. Installation and Startup NetworX Series NX-6 CONTROL PANEL Installation and Startup 25 GE Security All rights reserved. These instructions do not purport to cover all details or variations in equipment nor to provide every possible

More information

Model 17A00 Expansion Enclosure

Model 17A00 Expansion Enclosure HOME AUTOMATION, INC. Model 17A00 Expansion Enclosure Installation Manual Document Number 17I00-1 Rev A March, 2002 Home Automation, Inc. Model 17A00 Expansion Enclosure Installation Manual Document Number

More information

ITI Caretaker Basic Commands

ITI Caretaker Basic Commands ITI Caretaker Basic Commands System can be accessed by telephone or wireless keypad Zones - Up to 30 Wireless or 24 Hardwired Battery - 12 volt 1.9 amp rechargeable Lead-Acid inside main panel, only found

More information

The complete wirefree security alarm solution

The complete wirefree security alarm solution The complete wirefree security alarm solution www.espuk.com Wirefree home security and management system Infinite prime offers the professional installer a comprehensive and reliable intruder alarm solution

More information

CC408. Quick Reference Guide Solution 880

CC408. Quick Reference Guide Solution 880 CC408 EN Quick Reference Guide Solution 880 CC408 Quick Reference Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch

More information

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual WIC-16Z4P WIC-5Z2P Installation & Operation User Manual Page : 1/34 INDEX # Function Page 1 Abort Current Communication and Clear Reporting Queue (*59) 13 2 Abort Current Communications (*59) 10 3 Account

More information

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX PROGRAMMING GUIDE SPECTRA CONTROL PANELS V1.2 1725, 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX TABLE OF CONTENTS HOW DO I PROGRAM THE SYSTEM?... 4 Single Digit Data Entry Method (Hexadecimal

More information

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0 User s Guide SUB-MA7240O-0001.OG.Solution40-111.doc Created: 6/05/03 Last Updated: 23/09/03 MA7240AO-0001 Version 1.0 2 Table Of Contents User List...6 Quick Reference..7 Features...7 Keypad User's Guide...8

More information

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi 50 (P/N 10-071) is a state-of-the-art true intelligent digital peer-to-peer modular suppression control system.

More information

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.

More information

Security Alarm Systems

Security Alarm Systems eclipse Security Alarm Systems Contents Introduction 2 System Configuration 3 Control Panels 4 Remote Keypads & Expanders 5 Communication Modules 6 Upload/Download 6 Specifications 7 Introduction Zeta

More information

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher IMPORTANT WARNING:This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be

More information

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION...P.2 2. STANDARD AND OPTIONAL PARTS LIST...P.2 3. FEATURE DEFINITIONS...P.3 4. TERMINAL DRAWING AND

More information

Control/Communicator

Control/Communicator Architectural & Engineering Specifications Control/Communicator 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality

More information

System Introduction. 1.1 Specifications S E C T I O N 1

System Introduction. 1.1 Specifications S E C T I O N 1 System Introduction S E C T I O N 1 1.1 Specifications Control Panel Specifications Flexible Zone Configuration: 8 Fully Programmable Zones 37 Access Codes: 32 User, 1 System Master, 2 Partition Master

More information

Installation Instructions

Installation Instructions g 466-2339A October 2009 2009 GE Security, Inc. Introduction This is the GE. Installations should only be done by trained professionals. Use this document to install the system with default settings that

More information

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00 INHEP DIGITAL IDS S E C U R I T Y IDS816 User Manual MANUAL NO. 700-283-01 B ISSUED DEC 2004 VERSION 2.00 Contents 1. Introduction to the IDS816... 4 2. Understanding the Keypad Indicators... 4 3. Programmable

More information

NX-4V2 Control Panel Installation Instructions

NX-4V2 Control Panel Installation Instructions 4V2 Control Panel Installation Instructions Introduction This is the 4V2-Control Panel Installation Instructions. Installations should only be done by trained professionals. Use this document to install

More information

INSTALLATION GUIDE XTLN-WIFI PANEL

INSTALLATION GUIDE XTLN-WIFI PANEL INSTALLATION GUIDE XTLN-WIFI PANEL MODEL XTLN-WiFi INSTALLATION GUIDE FCC NOTICE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of

More information

Advent Home Navigator Product Line Overview Advent Home Navigator Named Best Network Subsystem

Advent Home Navigator Product Line Overview Advent Home Navigator Named Best Network Subsystem Product Line Overview Advent Home Navigator Product Line Overview Advent Home Navigator Named Best Network Subsystem Product Line Overview Advent Home Navigator System Protect the Homestead. Run the Household.

More information

CC488. Quick Reference Guide Solution Ultima 880

CC488. Quick Reference Guide Solution Ultima 880 CC488 EN Quick Reference Guide Solution Ultima 880 CC488 Quick Reference Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty

More information

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2 Architectural & Engineering Specifications Control Panel 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality assurance...

More information

Watchguard WGAP864 User Manual

Watchguard WGAP864 User Manual Watchguard WGAP864 User Manual v1.0 Issued September 2016 1 2 Table of Contents Glossary... 5 1. Introduction to your Watchguard WGAP864... 6 2. Before Operating your Alarm System... 6 3. Understanding

More information

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi (P/N 10-068) is a state-of-the-art true intelligent digital peer-topeer modular suppression control system. It is ideal for

More information

Wireless Sensors. Security unplugged. Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications.

Wireless Sensors. Security unplugged. Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications. Wireless Sensors Security unplugged Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications. Wireless sensing technology to secure what matters most Designed

More information

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2 INSTALLATION 3 Mounting the Panel... 3 Mounting the Keypad... 3 Auxiliary Power Connection... 3 PGM Terminal Connections... 3 Bell/Siren Connection... 3 Keypad

More information

Easy Series Intrusion Control Panel. Selection Guide

Easy Series Intrusion Control Panel. Selection Guide Easy Series Intrusion Control Panel Selection Guide Content 3 1. Core Facts 2. System Overview 5 2.1 Easy Series Control Center 6 Easy Series Display States 7 2.2 Control Panel and Devices 10 2.3 Easy

More information

IC60 Sintony 60 Intrusion Control Panel

IC60 Sintony 60 Intrusion Control Panel IC60 Sintony 60 Intrusion Control Panel for home and small businesses Multifunctional intrusion control panel for highest requirements Outstanding modern design Wired or/and wireless peripherals connectable

More information

Intelligent technology made simple

Intelligent technology made simple Intelligent technology made simple Freedom F-64: 8 to 64-zone hybrid security system featuring multifunction talking custom alpha touchpad with intelligent exit/entry technology for up to 8 doors of code-free,

More information

VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access

VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access Designed to integrate seamlessly with, access control and ADEMCO s full range of fire and burglary components, the VISTA-32FB provides the ultimate protection of life and property. The UL listed Fire and

More information

Installation Manual Premier 412/816/832. Issue 10

Installation Manual Premier 412/816/832. Issue 10 Installation Manual Premier // Issue 0 Premier // Installation Manual 5. Operating the System Introduction Before attempting to operate the alarm system ensure you have familiarised yourself with all the

More information

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC Take Fire Protection to the Next Level Fire Products from DSC AFD2000 Addressable Fire Control Panel Series Provides Maximum Flexibility The new AFD2000 is a completely programmable series of addressable,

More information

2000 Series. Program Entry Guide. Control Panels

2000 Series. Program Entry Guide. Control Panels 2000 Series EN Program Entry Guide Control Panels 2000 Series Program Entry Guide About This Manual EN 2 About This Manual This guide describes the programming parameters available to the 2000 Series Control

More information

OJD ITB No Attachment E Duress Alarm Equipment Specifications

OJD ITB No Attachment E Duress Alarm Equipment Specifications Duress Alarm Equipment Specifications PART 1 GENERAL 1.1 SECTION INCLUDES A. Duress devices. B. Alarm control panel. C. Signaling devices. 1.2 REFERENCE STANDARDS A. NFPA 70 - National Electrical Code;

More information

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216 16-128 Zone Control Panel PC4020 16 zones on main control panel supports up to 16 hardwired keypads Expandable up to 128 zones using hardwire, wireless modules and addressable zones COMBUS hardwired expansion

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING -961212-0004 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. ( 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2) Connect

More information

RE6100 Series Helix Security and Automation Platform

RE6100 Series Helix Security and Automation Platform CONFIGURATION Resolution Compatibles RE6100 Series Helix Security and Automation Platform C G UI D E Configuration Settings Table 1 - Panel Settings Table 2 - Zone Settings Table 3 - Device Settings Table

More information

Contents. Glossary

Contents. Glossary Contents Glossary ------------------------------------------------------------------------------------------------------ 6 1. Introduction to the IDS 1632 -------------------------------------------------------------

More information

System Introduction. 1.1 Specifications

System Introduction. 1.1 Specifications System Introduction S E C T I O N 1 1.1 Specifications Downloading Software Support PC585 uses DLS-1 v6.5 and up. Flexible Zone Configuration Four fully programmable zones; system expandable to eight zones

More information

Integrated Security Solutions

Integrated Security Solutions Integrated Security Solutions Table of Contents Control Panels 4 Keypads 8 Communication Modules 16 I/O Expanders 20 Door Control 24 Home Automation 25 RF Receivers 26 3 Our integrated security solutions

More information

>WIRELESS> ALARM SYSTEM CR200

>WIRELESS> ALARM SYSTEM CR200 intrusion >WIRELESS> ALARM SYSTEM CR200 INTRUSION HOME SECURITY CR200 is a Modern, Effective and Versatile 20-zone Household Security System. It is packed with simple Plug & Play functionality, designed

More information

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand 6 Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd Operating Guide 1 Proudly Designed and Manufactured in New Zealand CONTENTS Page No. INTRODUCTION 3 About your Alarm 3 OPERATING YOUR

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING 48ESEP-01 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)

More information

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel Designed to integrate seamlessly with, access control, and ADEMCO s full range of fire and burglary components, the

More information

DOOR MONITORING/DURESS SYSTEM

DOOR MONITORING/DURESS SYSTEM SECTION PART 1 - GENERAL 1.1 RELATED SECTIONS A. Comply with the requirements of Section 27 05 00 Common Work Results for Communications. 1.2 DEFINITIONS A. Not used. 1.3 DESCRIPTION OF SYSTEM: A. Provide

More information

ACP10 & ACP50 Security Systems

ACP10 & ACP50 Security Systems ACP10 & ACP50 Security Systems System Configuration LCD Keypad LCD Keypad LED Keypad LED Keypad 4-wire Bus ACP10 & ACP50 AEX10* AEX10* AEX10* AEX10* * ACP50 Only Control Panels The ACP10 control panel

More information

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68) F A 1 7 0 0 c Testing the System Battery Test When AC power is present, the FA1700C runs a brief battery test every 60 seconds to determine if there is a battery connected, and runs an extended battery

More information

SENTROL ZX200/ZX210. Security System Control. Installation/ Programming

SENTROL ZX200/ZX210. Security System Control. Installation/ Programming SENTROL ZX200/ZX210 Security System Control Installation/ Programming 1 2 TABLE OF CONTENTS Table of Contents Feature Overview... 5 A New Standard For Value...5 ZX System Advantages...5 More Than A Security

More information

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1 0 4 / 0 4 / 1 4 GE Concord 4 Quick User Guide GE Concord 4 Quick User Guide Page 1 Before Calling Is the keypad beeping? Press *. This will silence the beeping and let you know where the trouble is. Is

More information

INSTALLATION MANUAL PC15OO

INSTALLATION MANUAL PC15OO INSTALLATION MANUAL PC15OO This device complies with Parts 15 and 68 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2)

More information

XTLC PANEL INSTALLATION GUIDE

XTLC PANEL INSTALLATION GUIDE XTLC PANEL INSTALLATION GUIDE MODEL XTLC INSTALLATION GUIDE FCC NOTICE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

More information

First Alert 1200C Installer Notes M. Leuck

First Alert 1200C Installer Notes M. Leuck First Alert 2C Installer Notes M. Leuck. Programming can done by standard keypads 2. Enter programming with Installer Code + 8 + + 3. Another method of entering programming: Power system down, then back

More information

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual All-In-One Wireless Security System V1.0 Model #: MG-6060 Reference and Installation Manual Table of Contents Introduction... 3 About Magellan and this Manual... 3 Conventions... 3 Specifications... 3

More information

Integrated Security Solutions

Integrated Security Solutions Integrated Security Solutions Table of Contents Control Panels 4 Keypads 8 Communication Modules 16 I/O Expanders 20 Door Control 24 Home Automation 25 RF Receivers 26 2 Our integrated security solutions

More information

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure. Notice The material and instructions covered in this manual have been carefully checked for accuracy and are presumed to be reliable. However, Radionics, Inc. assumes no responsibility for inaccuracies

More information

INTRODUCTION. The use of any power source other than a PC4204 to repower the Combus will result in a system malfunction.

INTRODUCTION. The use of any power source other than a PC4204 to repower the Combus will result in a system malfunction. INTRODUCTION The PC4020 is a highly flexible and versatile control which will enable the installer to meet the most demanding security requirements. The heart of the system is the main control panel, designated

More information

Contact ID as of 2/2/2015

Contact ID as of 2/2/2015 Contact ID as of 2/2/2015 100 Medical Zone A non-specific medical exists 101 Personal Emergency Zone Emergency Assistance request 102 Fail to report in Zone A user has failed to activate a monitoring device

More information

AXI LED USER MANUAL (REV. 1.0)

AXI LED USER MANUAL (REV. 1.0) Security & Home Automation System AXI LED USER MANUAL (REV. 1.0) CONTENTS PREFACE FEATURES LED KEYPAD OUTLOOK 1.0 LIGHT INDICATION 1 2 4 6 CHAPTER 1: ALARM SYSTEM CONTROL 1.0 USING LED KEYPAD 1.0.1 ARMING

More information

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Intelligent 2 & 4 Loop Fire Alarm Control Panels Intelligent 2 & 4 Loop Fire Alarm Control Panels Advanced has combined the latest technology with many years of fire experience, to create the Axis AX Series Intelligent Fire Alarm Control Panels. The

More information

Intelligent Single Loop Fire Alarm Control Panel

Intelligent Single Loop Fire Alarm Control Panel Intelligent Single Loop Fire Alarm Control Panel The CAX-CTL-1L Intelligent Single Loop Fire Alarm Control Panel is a member of the industry leading Axis AX Series Intelligent Fre Alarm Control Panels

More information

Product Catalog 2nd Quarter 1997

Product Catalog 2nd Quarter 1997 Product Catalog 2nd Quarter 1997 Contents ITI Wireless Systems 1 Innovative Technology 1 Product Compatibility Table 2 Features Comparison Table 4 UltraGard Security & Home Automation System 5 System Profile

More information

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide MG6250 2-Partition 64-Zone Wireless Console with GPRS/GSM Version.6 Section Programming Guide Things You Need to Know About this Programming Guide The MG6250 All-in-one Wireless Console can be programmed

More information

EC-P Zone Intruder Alarm System

EC-P Zone Intruder Alarm System EC-P10 10-20 Zone Intruder Alarm System Installation Manual Contents 1. System Overview... 4 System Configuration... 4 Control Panel... 5 Remote Keypads... 5 EC-LED Remote Keypad... 5 EC-LCD Remote Keypad...

More information

High-End Wireless Security

High-End Wireless Security PRODUCT CATALOGUE High-End Wireless Security The sophisticated iconnect system, with its sleek design, serves as the command center for a residential and small commercial Security and Home Automation network.

More information

Wireless Sensors. Security anywhere. Interlogix wireless sensors deliver highly accurate detection and easy installation for multiple applications.

Wireless Sensors. Security anywhere. Interlogix wireless sensors deliver highly accurate detection and easy installation for multiple applications. Wireless Sensors Security anywhere Interlogix wireless sensors deliver highly accurate detection and easy installation for multiple applications. Wireless sensing technology to effectively secure the most

More information

Wireless Devices. This chapter introduces the suite of DSC wireless sensors and devices used with the Impassa and other series of DSC alarm systems

Wireless Devices. This chapter introduces the suite of DSC wireless sensors and devices used with the Impassa and other series of DSC alarm systems Wireless Devices This chapter introduces the suite of DSC wireless sensors and devices used with the Impassa and other series of DSC alarm systems ALARM DETECTORS WS4945 DOOR/WINDOW SENSOR The WS4945 is

More information

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

IDS S E C U R I T Y IDS816.  User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00 INHEP DIGITAL IDS S E C U R I T Y IDS816 User Manual MANUAL NO. 700-283-02A ISSUED November 2004 VERSION 1.00 Contents 1. Introduction to the IDS816... 4 2. Understanding the Keypad Indicators... 4 3.

More information

System Overview. PC4020 v3.3

System Overview. PC4020 v3.3 System Overview PC4020 v3.3 The MAXSYS system meets today s challenges with the seamless integration of security, access control, fire alarm, automation, and intercom features that single function systems

More information

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM SECURITY ACCESS AND SURVEILLANCE SECTION 13850 VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM ADEMCO Group 165 Eileen Way Syosset, New York 11791 1-800-645-7568 SECTION 13850 DETECTION

More information

NX-10 wireless keypad. To wire or not to wire?

NX-10 wireless keypad. To wire or not to wire? NX-10 wireless keypad To wire or not to wire? Now your security goes where you go Our NX-10 system is fully wireless with a keypad in a designer housing. The NX-10 series goes where no security system

More information

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200 FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200 1.0 General 1.1 Manufacturer Manufacturer of the Fire Alarm Control Panel (FACP) equipment shall be: Digital Monitoring Products, Incorporated 2500 N.

More information

EasyLoader AV-2005 & AV-2008

EasyLoader AV-2005 & AV-2008 EasyLoader AV-2005 & AV-2008 Integrated Alarm Control/Communicator Year 2000 ready Installation and Operation Manual Version 2.17C Edition IIII This product is subject to continuous enhancements and therefore

More information

Summit 3208GLD USER MANUAL. Electronics Line

Summit 3208GLD USER MANUAL. Electronics Line Summit 3208GLD USER MANUAL Electronics Line Table of Contents 1: Introduction... 2 2: Overview... 3 3: Keypad Functions... 4 3.1: Keypads... 4 3.2: 3108 LCD Keypad Layout... 4 4: Basic System Operation...

More information