9

10

11

12

13 CUSTOMS UNION Translation CERTIFICATE OF CONFORMITY No. RU -D Series RU No CERTIFICATION BODY FOR EXPLOSION-PROOF EQUIPMENT AT CLOSED J.-ST. CO. "TESTING CENTRE FOR TECHNICAL MEASUREMENTS, SAFETY AND DEVELOPMENTS" ( ) See the accreditation certificate No. RU with the period of validity from until issued by the Federal Agency of Technical Regulation and Metrology. Address: Moscow, 75 Friedrich-Engels-Str., building 11, office 204, Russia (legal address); , region Tula, town Donskoy, 1 Gornospasatelnaya-Str., building, Russia (physical address) Tel./fax: (48746) , pmv@tibcr.ru APPLICANT: AO "WIKA MERA", Taxpayer Reg. No.: , Primary State Registration Number: Address: Moscow, Ul. Wjatskaya 27, GB 17, Russia Tel.: , fax: , info@wika.ru MANUFACTURER: PRODUCTS: KSR KUEBLER Niveau-Messtechnik AG Address: Heinrich-Kuebler-Platz 1, Zwingenberg, Germany Tel.: , fax: ; info@ksr-kueblcr.com Manufacturing plants: see Annex (printed form No ). Devices trademarked by KSR KUEBLER/WIKA for measuring and controlling fluid level & flow provided with the explosion-proof mark and combustible dust ignition-proof markl in accordance with the Annex. Said devices being of serial production Foreign Economic Activity Commodity Nomenclature , for the Customs Union CORRESPONDS TO THE REQUIREMENTS of the Customs Union Technical Regulation "Matters of Equipment Safety for Operation with Explosion-Hazardous Media" ( 012/2011). THIS CERTIFICATE WAS ISSUED ON THE BASIS OF: Test Record No. 806/856- dated , see Proceedings of the test laboratory for explosion-proof equipment at Closed J.-St. Co. dealing with technical measurements, safety and developments ( ), Reg. No. RU (dated until ). Address: , region Tula, town Donskoy, 1 Gornospasatelnaya-Str., building, Russia Reference: Report on the Condition Analysis of the Manufacturer's Production No. 648/ dated ADDITIONAL INFORMATION Estimation (confirmation) scheme of the compliance with 1: The Certificate is valid only in conjunction with the Annex (printed forms Nos , , , , , , , , , , ). Period of validity: from until INCLUSIVE Head Officer (Authorized Person) Expert (Expert/Auditor) (Experts (Experts/Auditors)) M. W. Ponamarev A. A. Shmelyov

14 CUSTOMS UNION CUSTOMS UNION ANNEX TO THE CERTIFICATE OF CONFORMITY No. RU -D Series RU No Translation List of manufacturing plants producing the products subject to the validity of the Certificate of Conformity Full name of the Manufacturing Plant Address (Location) KSR KUEBLER Niveau-Messtechnik AG WIKA Alexander Wiegand SE&Co.KG Heinrich-Kuebler-Platz 1, Zwingenberg, Germany Alexander-Wiegand-Straße 30, Klingenberg, Germany - Head Officer (Authorized Person) of Certification Body xpert (Expert/Auditor) (Experts (Experts/Auditors)) M. W. Ponamarev A. A. Shmelyov

15 Head Officer (Authorized Person) of Certification Body Designation of National Standard or Code of Practice ANNEX TO THE CERTIFICATE OF CONFORMITY No. RU -D S e r i e s R U N o Data on national standards (codes of practice) to be used on a voluntary basis for adherence to requirements of technical regulations Name of National Standard or Code of Practice Translation Confirmation of Compliance with Requirements of the National Standard or Code of Practice I Explosion-hazardous media. Part 0. Equipment. General requirements. Explosion-hazardous media. Part 1. Equipment in explosion-proof category «explosion-proof enclosures d». Standard as a whole Standard as a whole Explosion-hazardous media. Part 11. Intrinsically safe electrical circuit «i». Standard as a whole / IEC : / IEC :2006 Explosion-hazardous media. Part 18. Equipment with explosion-proof category «compound encapsulation "m"» Explosion-hazardous media. Part 28. Protection of equipment and transmitting systems that use optical emission. Explosion-hazardous media. Part 26. Equipment with explosion-proof level Ga. Standard as a whole Standard as a whole Standard as a whole Explosion-hazardous media. Part 31. Equipment with explosion-proof category «t» against dust ignition. Standard as a whole Non-electric equipment designated for usage in (EN potentially explosion-hazardous media. Part 1. 1:2001) General requirements. Standard as a whole (EN Non-electric equipment designated for usage in potentially explosion-hazardous media. Part 5. Protection due to design safety. Standard as a whole Head Officer (Authorized Person) of Certification Body M. W. Ponamarev \Expert (Expert/Auditor) (Experts (Experts/Auditors)) A. A. Shmelyov

16 ANNEX TO THE CERTIFICATE OF CONFORMITY No. RU -D Designation and Field of Application Series RU N o Translation Devices trademarked by KSR KUEBLER/WIKA for measuring and controlling fluid level & flow (see Table 1 in this Annex) are designated for use in various branches of industry for controlling and/or continuously measuring fluid level or flow. Devices trademarked by KSR KUEBLER/WIKA for measuring and controlling fluid level & flow belong to explosion-proof equipment group II acc. to standards , (EN :2001) and are designated for use in explosion-hazardous zones of rooms and at outdoor facilities in accordance with assigned explosion-proof marking. Devices trademarked by KSR KUEBLER/WIKA for measuring and controlling fluid level & flow belong to equipment group III acc. to the standard and are designated for use in hazardous zones in terms of combustible dust ignition in accordance with the assigned marking of protection against combustible dust ignition. 2. Description of the Design and Description of the Utilities for Explosion-Proofing and Protection against Combustible Dust Ignition Float-type magnetic reed switches series/types 60, AL-ADF..., FLS-..., MSI EX, SLS-..., H...-Ex, HLS-..., level sensors series/types MG...Ex, NMG125, AF-ADF..., AVK-ADF..., FLR-.., BLR-... operate on the principle of a float with magnetic transmission. Inside of the slide tube, there are one or several reed relays. On the slide tube, there are floats that change their height related position subject to the level of controllable medium. Optionally, the devices can also be equipped with resistive temperature transducers, thermo-relays, Namur switches. Depending on their design, float-type magnetic reed switches are fixed in vessels by means of a flange or threaded connection. Level sensors series/types FFG-T.., FFG-BT, FFG-P, FFG-BP..., FLM-, BLM- consist of the primary sensor encapsulated in a hermetic metallic pipe (measuring rod) and the block of electronics (sensor head). Level switches of series/type KSR- 21*.06, OLS-..., OPG51, OLS-C51 consist of the infrared light-emitting diode and phototransistor. Light from the light-emitting diode is transmitted to the prism located within the working section of the switch. With the prism in the air, light is reflected to the receiver, when the prism is immersed, the beam of light is refracted and does not reach the receiver; this effect is enhanced by an electronic circuitry and leads to actuation. Amplifiers fromseries/types KSR- OPTO.25G2.xx, OSA... represent an electronic device designated for signal multiplication from the switch KSR- OPT0.21*.06xx, OLS-... at its usage in the fluid level control system. Bypass level indicators from series/types BNA..., UTN... operate on the principle of the communicating vessel. In this vessel, the float is installed with a built-in permanent magnet. Float height-along-position is changed subject to the level of the medium. Magnetic field switches on visual or electric level indicators or magnetic switches are installed from the outside, on the bypass tube. Magnetic switches BGU... are switches following the non-contact principle of operation to be installed without immersion into the controllable medium. The main elements are the body and hermetic contacts (reed relays) built-in into the latter. Reed relays actuate when there is an interaction with a magnetic field of a permanent magnet. Flow switches from series/types RV..., DW..., DK..., DU..., FWS-... represent hermetically sealed normally open (N. O.) or SPDT switches encapsulated in a plastic body. Illumination devices for level indicators from series/types 709, LGG-I represent the lamp installed in an explosion-proof body. They are used as ready-mounted devices with glass-made level indicators. Intermediate relays for level sensors from series/types KR24- Ex, KR230- represent electronic devices designated for transmission of signals from level switches into the control system. Electric signal converters for level sensors from series/types,, TLEH are arranged in a cylindrical body. There are junction blocks located on the side surface of the body. Within the body, there are printed-circuit boards with elements of electric circuit. Head Officer (Authorized Person) of Certification Body Expert (Expert/Auditor) Experts (Experts/Auditors) M. W. Ponamarev A. A. Shmelyov

17 ANNEX ANNEX Translation TO THE CERTIFICATE OF CONFORMITY No. RU -D Explosion protection of level measuring devices is provided by the explosion-proofness type "explosion-proof enclosure «d»" acc. to the standard IEC , protection type "intrinsically safe electrical circuit of level «ia»" acc. to the standard , protection type "compound encapsulation «mb»" acc. to the standard , "protection of equipment and transmitting systems that use optical emission" acc. to the standard /IEC :2006, "protection due to design safety " acc. to the standard (EN :2003), "protective enclosure «t»" acc. to the standard , and designing them in accordance with the requirements of the standards , (EN :2001). 3. Special Application Conditions (if explosion-proof marking contains the sign «X») The sign «X» within the explosion-proof marking of magnetic float-type level switches of series/type 60, horizontal level switches of series/type...-, level sensors from series/types MG...Ex, NMG125, FFG-T..., FFG-BT... means: mounting, operation, maintenance of devices shall be performed in compliance with instructions of the Manufacturer on the basis of his technical documents; temperature class of devices shall be determined by ambient temperature and working medium (process) temperature in accordance with the Manufacturer's technical documents; when using devices made of titanium alloy, in order to eliminate the danger of ignition due to sparks generated as a result of friction or collision of parts, exposing the devices to friction or impacts that may lead to sparking is not permitted. The sign «X» within the explosion-proof marking for magnetic float-type level switches from series/type AL- ADF..., level sensors from series/types AF-ADF... AVK-ADF... means: mounting, operation, maintenance of devices shall be performed in compliance with instructions of the Manufacturer on the basis of his technical documents; equipment is designated for use with electrically conducting media in order to eliminate static electricity accumulation. If the devices are intended for use in a non-conducting medium, the consumer/user should assume the measures for eliminating static electricity accumulation. The sign «X» within the explosion-proof marking for suspended float-type level switches from series/type MSI EX means that this article is equipped with a permanently connected cable. The sign «X» within the explosion-proof marking for level sensors from series/types FFG-P..., FFG-BP... means: mounting, operation, maintenance of devices shall be performed in compliance with instructions of the Manufacturer on the basis of his technical documents; the temperature class shall be determined by the ambient temperature in accordance with the Manufacturer's technical documents. The sign «X» within the explosion-proof marking for level indicators from series/types BNA..., UTN... means: mounting, operation, maintenance of devices shall be performed in compliance with instructions of the Manufacturer on the basis of his technical documents; the temperature class of devices shall be determined by ambient temperature and working medium (process) temperature in accordance with the Manufacturer's technical documents. The sign «X» within the explosion-proof marking for level switches from series/types OPG51, OLS-C51 means: mounting, operation, maintenance of devices shall be performed in compliance with instructions of the Manufacturer on the basis of his technical documents. The sign «X» within the explosion-proof marking for level switches from series/type BGU... means: mounting, operation, maintenance of devices shall be performed in compliance with instructions of the Manufacturer on the basis of his technical documents. the temperature class of devices shall be determined by the ambient temperature in accordance with the Manufacturer's technical documents; Head Officer (Authorized Person) of Certification Body Expert (Expert/Auditor) (Experts (Experts/Auditors)) M. W. Ponamarev A. A. Shmelyov

18 ANNEX ANNEX TO THE CERTIFICATE OF CONFORMITY No. RU -D when using devices made of aluminium alloy, in order to eliminate the danger of ignition due to sparks generated as a result of friction or collision of parts, during installation and operation of the devices in zone 0 exposing the devices to friction or impacts that may lead to sparking is not permitted. The sign «X» within the explosion-proof marking for illumination devices for level indicators from series/type means: mounting, operation, maintenance of devices shall be performed in compliance with instructions of the Manufacturer on the basis of his technical documents; the temperature class and maximum surface temperature of the devices shall be determined by the ambient temperature in accordance with the Manufacturer's technical documents; after having disconnected devices from the network, they cannot be opened before 20 minutes have passed. The sign «X» within the explosion-proof marking for flow switches from series/types RV..., DW..., DK..., DU... means: mounting, operation, maintenance of devices shall be performed in compliance with instructions of the Manufacturer on the basis of his technical documents; switches should not be cleaned in explosion-hazardous zones; plastic bodies should not be exposed to electrostatic charging. If there is no such certainty, the body should be completely discharged outside of the explosion-hazardous zone by bringing it in contact with an earthed metallic element; the sensing part of the switch (in the part opposite to the cable inlet) is flexible according to its function and should be protected from mechanical damages when being removed from the device; the device should be mounted in such a way that the connecting cable cannot be jammed or otherwise damaged and should not come into contact with surfaces, the temperature of which exceeds 75 (for class 6) or 90 (for class 5). Switches should not be mounted on equipment exposed to heavy vibrations as vibrations can cause such problems as weakening threaded connections, incorrect actuation of contacts, damage or breakage of the cable; switches can be connected to circuits that do not include effective inductive and effective capacitive components. To protect contacts, fuses of respective rating should be used. The sign «X» within the explosion-proof marking for built-in electric signal converters for level sensors from series/types,, TLEH means: mounting, operation, maintenance of devices shall be performed in compliance with instructions of the Manufacturer on the basis of his technical documents; the temperature class and maximum surface temperature of the devices shall be determined by the ambient temperature in accordance with the Manufacturer's technical documents. 4. Marking Translation Marking to be applied to equipment should include the following data: 1) the Manufacturer's name or registered trade mark; 2) designation of the equipment type; 3) serial number; 4) number of the Certificate of Conformity; 5) explosion-proof labelling and combustible dust ignition-proof labelling in accordance with Table 1, see item 5 of this Annex; 6) picture of a special sign meaning the non-explosiveness in accordance with the Customs Union Technical Regulation ( 012/2011) (Annex 2); 7) other data required by regulatory and technical documents, which are to be reflected by the Manufacturer within the marking. 5. Composition, Design Version and Specifications of the Article Devices trademarked by KSR KUEBLER/WIKA for measuring and controlling fluid level & flow that fall under the scope of applicability of the Certificate of Conformity and their explosion-proofn labelling and combustible dust ignition-proof labelling are provided in Table 1. Head Officer (Authorized Person) of Certification Body Expert (Expert/Auditor) (Experts (Experts/Auditors)) M. W. Ponamarev (initials, name) A. A. Shmelyov

CERTIFICATE OF CONFORMITY No. TC RU С- DE.AB72.B.02315 Series RU No. 0492042 CERTIFICATION AUTHORITIES Certification authority of products of "Scientific and Technical Center "Techno-standard Limited Liability

More information

Magnetostrictive sensor For bypass level indicators Model BLM

Magnetostrictive sensor For bypass level indicators Model BLM Level Magnetostrictive sensor For bypass level indicators Model BLM KSR data sheet LM 10.05 for further approvals see page 2 and 3 Applications Sensor for the continuous level measurement of liquids in

More information

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 4.1 Electrical limit switch... 4

More information

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm

More information

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU GENERAL The accidental ignition of an atmosphere containing a large quantity of gas, vapour, mists and/or dust may cause an explosion. Specific

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70033893 (166720) Issued to: WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Str 30 Klingenberg, 63911 GERMANY Attention: Uwe Schmidt The products listed below

More information

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection Skip to main content Skip to primary navigation Home Home About this portal Latest updates Menu Print Save Email Resource detail Citations AS/NZS 60079.14:2009 Explosive atmospheres - Part 14: Electrical

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 17065:2012 to provide product conformity certification Newport Business Park New Port Road Ellesmere Port CH65 4LZ United Kingdom Contact:

More information

Safety instructions VEGAPULS 64

Safety instructions VEGAPULS 64 Safety instructions Intrinsic safety "i" 4 20 ma/hart - two-wire Document ID: 53001 Contents 1 Area of applicability... 3 2 Important specification in the type code... 3 3 Different ignition protection

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators EC-Type Examination Certificate TÜV99 ATEX 1479X Accessories BT32 BT32XS BT32XAS BT33 BT34 V1-G-N4-5M-PUR Female cordset, M12, 4-pin, NAMUR,

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

Optoelectronic level switches, models OLS-C. Optoelektronische Füllstandsschalter, Typen OLS-C. Commutateurs de niveau opto-électroniques, type OLS-C

Optoelectronic level switches, models OLS-C. Optoelektronische Füllstandsschalter, Typen OLS-C. Commutateurs de niveau opto-électroniques, type OLS-C Operating instructions Operating instructions Betriebsanleitung Mode d'emploi Manual de instrucciones Optoelectronic level switches, models OLS-C Optoelektronische Füllstandsschalter, Typen OLS-C Commutateurs

More information

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining The Laboratory is qualified to update standards identifying the test procedures. The laboratory requires/applies a flexible scope of accreditation permitted as detailed in the Annex. Updated list of activities

More information

OPTIBAR P 1010/2010 C Supplementary instructions

OPTIBAR P 1010/2010 C Supplementary instructions OPTIBAR P 1010/2010 C Supplementary instructions Pressure transmitter Equipment category II 1G / Ga, II 1D / Da in protection type intrinsic safety Exi KROHNE CONTENTS OPTIBAR P 1010/2010 C 1 Safety instructions

More information

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY POINT LEVEL DETECTION In applications like overfill protection, min/max control, or overflow and dry-run protection, the limit value switches

More information

(German speaking trainers with English written slides)

(German speaking trainers with English written slides) Kiwa organizes dedicated training courses in Germany (Hannover, Kaufbeuren) especially for German manufacturers and at Kiwa in Apeldoorn, The Netherlands. Language spoken is German and English (German

More information

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates Note: While this material was originally prepared for presentation in February 1999, it has been updated to reflect the evolving technical requirements now applicable as of April 2003. UL Topic III Converting

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 50 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 50 mm Installation non-flush Output polarity NAMUR

More information

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres Z31.0.XX.6C-11 Temperature Probe for potentially explosive atmospheres (Measuring ranges from -200 to +900 C) Operating Manual GTF 103-Ex 0081 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße

More information

Dual certification! Air handling units for potentially explosive atmospheres

Dual certification! Air handling units for potentially explosive atmospheres Dual certification! Air handling units for potentially explosive atmospheres X-CUBE Ex A certified safety product The air handling unit with dual ATEX certification ATEX directive 2014/34/EU applies to

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 5 mm flush Usable up to SIL2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching element

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000

More information

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US. Flexible Schedule of Accreditation SIRA CERTIFICATION SERVICE. Issue No: 63A Issue date 16 th June 2015 Unit 6 Hawarden Industrial Park Hawarden, CH5 3US, United Kingdom Contact: Mr A Myler Tel: +44 (0)1244

More information

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 17065:2012 to provide product conformity certification Unit 16-18 Abenbury Way Wrexham Industrial Estate Wrexham LL13 9UZ United Kingdom Contact:

More information

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US. Flexible Schedule of Accreditation SIRA CERTIFICATION SERVICE. Issue No: 072A Issue date 23 rd March 2018 Unit 6 Hawarden Industrial Park Hawarden, CH5 3US, United Kingdom Contact: Mr A Myler Tel: +44

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

SET Installation and Operating Instructions. Level switch for one sensor

SET Installation and Operating Instructions. Level switch for one sensor Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel.: +358 29 006 260 Fax: +358 29 006 1260 7.11.2013 Internet: www.labkotec.fi 1/14 SET-1000 Level switch for one sensor Copyright 2013 Labkotec Oy

More information

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S D10 is a type-approved measuring device which combines the advantages of the measuring principles transmittance and scattered light forward. Therefore, it is ideal for measurement of very low to high dust

More information

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm 0102 Model Number Features 8 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

1510 Side Mounted Level Switch

1510 Side Mounted Level Switch 1510 Side Mounted Level Switch General Instructions The SOR 1510 Level Switch mounts into the side of a vessel. Electric switching action is provided by the float moving a magnet into the field of a hermetically

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 15 mm Installation non-flush Assured operating distance s a 0...

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 8 mm non-flush Stainless steel housing Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 8 mm

More information

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT Olof Bekker Pr. Eng. BSc. Eng. BML S.MSAIEE, M.NACE Engineering Manager, Electrical COMMITMENT

More information

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description Magnetic-Inductive Flow Velocity Sensor PIT Device Description Table of contents 1 IDENTIFICATION...3 1.1 Manufacturer/supplier...3 1.2 Product type...3 1.3 Product name...3 1.4 Issue date...3 1.5 Version

More information

Indoor/outdoor resistance thermometer Model TR60

Indoor/outdoor resistance thermometer Model TR60 Temperature Indoor/outdoor resistance thermometer Model TR60 WIKA data sheet TE 60.60 for further approvals see page 2 Applications Ambient temperature measurement Air-conditioned rooms, cold-storage rooms,

More information

Gas cylinder scale Model GCS-1

Gas cylinder scale Model GCS-1 Electronic pressure measurement Gas cylinder scale Model GCS-1 WIKA data sheet PE 87.19 Applications Level measurement of liquid gases in gas cabinets and gas distribution systems Level measurement in

More information

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS 10.0008 Ex td A20, A20/21, A20/22, A21 IP66 T 0044 37675 Contents 1 Area of applicability 3 2 General information 3 2.1 Zone 20 instruments

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

PEPPERL+FUCHS GmbH

PEPPERL+FUCHS GmbH Comfort series 1.5 mm embeddable M8x1 4 25 16 13 LED Switching element function NAMUR NC Rated operating distance s n 1,5 mm Installation embeddable Assured operating distance s a 0... 1,215 mm Reduction

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions SET-000 Oil/Sludge Alarm Device for Oil Separators Copyright 007 Labkotec Oy We reserve the right for changes without notice TABLE OF CONTENTS GENERAL... INSTALLATION... 4. SET-000 Oil/Sludge Control Unit...

More information

INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME)

INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME) INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME) To: Members of the Management Committee ExMC Introductory

More information

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations) Annex II Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations) 1. According to Recommendation L, market surveillance should be included as a flanking area of

More information

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 94/9/EC

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 94/9/EC EUROPEN DIRECTIVES Explosive atmospheres TEX 94/9/EC GENERL The accidental ignition of an atmosphere containing a large quantity of gas, vapour, mists and/or dust may cause an explosion. Specifi c measures

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

OilSET Installation and Operating Instructions. Oil Separator Alarm Device Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 18.11.2010 Internet: www.labkotec.fi 1/10 OilSET-1000 Oil Separator Alarm Device Copyright 2010 Labkotec

More information

Operating instructions for HAWE devices

Operating instructions for HAWE devices Operating instructions for HAWE devices For designated use in potentially explosive atmospheres B- 04-2016-2.1 by HAWE Hydraulik SE. The forwarding and reproduction of this document, as well as the use

More information

VERSAFLOW VORTEX Supplementary instructions

VERSAFLOW VORTEX Supplementary instructions VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according

More information

E DATA SHEET

E DATA SHEET ISO 9001 UK-VK SWITCHING UNIT UK-VK rev.10 UK-VK rev.11 UK-VK rev.1 UK-VK rev.13 UK-VK rev.14 UK-VK rev.15 4641.00 E DATA SHEET 1 MAIN SPECIFICATIONS 1.1 General 1.1.1 This datasheet is applicable to the

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Accessories BF 12 Mounting flange, 12 mm Technical Data specifications Switching element function NAMUR, NO Rated operating distance s n 4 mm Installation non-flush

More information

OPTISENS TUR 2000 Technical Datasheet

OPTISENS TUR 2000 Technical Datasheet OPTISENS TUR 2000 Technical Datasheet Sensor for turbidity measurement in water and wastewater Rugged design for harsh applications Integrated transmitter with direct 4...20 ma output Near infrared light

More information

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS MCF 00 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS MCF 00 CENTRIFUGAL FAN FOR COMBUSTIBLE GASES MCF 00 centrifugal fan for biogas, natural gas or combustible gases, in conformity to the

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...

More information

SET-2000 Hi Level/Oil

SET-2000 Hi Level/Oil Labkotec Oy Labkotie 1 FI-36240 KANGASALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 13.03.2008 Internet: www.labkotec.fi Alarm Device for Oil Separators Copyright 2008 Labkotec Oy We reserve

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK SIRA Certification Service Accredited to ISO/IEC 17065:2012 to provide product conformity Unit 6 Hawarden Industrial Park Hawarden Deeside

More information

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40 Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40 Application Instrument designed to measure and indicate differential pressure or measured variables derived from it For gases or liquids

More information

UV Flame Supervision System

UV Flame Supervision System 7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running

More information

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics... 14 Ex SOLENOID / ALARM DRIVER PRepower 5203B Table of contents Warnings... 16 Safety instructions... 17 Declaration of Conformity... 19 How to dismantle SYSTEM 5000... 20 Application... 21 Technical characteristics...

More information

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions Magnetic-Inductive Flow Velocity Sensor PIT Installation and Operating Instructions Table of contents 1 IDENTIFICATION... 3 1.1 Manufacturer/supplier... 3 1.2 Product type... 3 1.3 Product name... 3 1.4

More information

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02 7 783 ISO 9001 DETACTOGYR Flame Safeguard Series 02 The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil

More information

Ultrasonic Point Level Switches

Ultrasonic Point Level Switches see more at SORInc.com Request Quote Ultrasonic Point Level Switches Ultrasonic point level switches are a cost-effective solution for your applications. Installation requires mounting the sensor (threaded

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

Declaration of Conformity

Declaration of Conformity Declaration of Conformity DEMONSTRATION OF CONFORMITY WITH RECOGNIZED STANDARDS TO SATISFY THE SAFETY AND EFFECTIVENESS REQUIREMENTS OF THE CANADIAN MEDICAL DEVICES REGULATIONS Name of the medical device

More information

Rules for Classification and Construction Additional Rules and Guidelines

Rules for Classification and Construction Additional Rules and Guidelines VI Rules for Classification and Construction Additional Rules and Guidelines 7 Guidelines for the Performance of Type Approvals 7 Test Requirements for Statical Converters with Semi-Conductors Edition

More information

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements ExTR Reference Number...: ExTR Free Reference Number...: 223531 Compiled by + signature (ExTL)...: Reviewed by + signature (ExTL)...: NO/NEM/ExTR12.0018/00 Stig André Norheim Arne Hortman Date of issue...:

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE Certificate No: E-14378 This is to certify: That the Pilot Device with type designation(s) Pilot device Issued to BARTEC GmbH BAD MERGENTHEIM, Germany is found to comply with

More information

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74 AM54 Instruction Bulletin North American Installation Addendum Document Number PN25016 Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

More information

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical

More information

Survey of electrical equipment installed in hazardous areas on tankers

Survey of electrical equipment installed in hazardous areas on tankers (June 2015) Survey of electrical equipment installed in hazardous areas on tankers 1. Application The recommendations in this document apply for survey of electrical installation in hazardous areas on

More information

Illumination unit For sight glass level indicator Model LGI

Illumination unit For sight glass level indicator Model LGI Level Illumination unit For sight glass level indicator Model LGI WIKA data sheet LM 33.02 for further approvals see page 2 Applications Better identification of liquid and gaseous phase Direct indication

More information

EXPLOSION PROTECTION

EXPLOSION PROTECTION EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY This is to certify that the product Cert NO.GYJ15.1225X Miniature Resistance Thermometer manufactured by WIKA Alexander Wiegand SE & Co.KG (Address:Aiexander-Wiegand-Stra6e

More information

UL HAZARDOUS LOCATIONS SERVICES

UL HAZARDOUS LOCATIONS SERVICES UL HAZARDOUS LOCATIONS SERVICES The international preference in hazardous locations certification for over 100 years ul.com/hazloc Explosive Gas Atmospheres Class I Division S Includes flammable gases,

More information

Functional Safety Manual Oil Leak Detector NAR300 System

Functional Safety Manual Oil Leak Detector NAR300 System SD01357G/08/EN/01.14 71255416 Products Solutions Services Functional Safety Manual Oil Leak Detector NAR300 System Application This system is designed to be installed in a pit, dike, plant, or sump pit

More information

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories Hazardous Locations: Understanding the Basics of Global Compliance Requirements Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories DISCLAIMER/ TERMS OF USE: THE INFORMATION

More information

5 m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NBMX-21-05

5 m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NBMX-21-05 Explosion proof Non-contact Safety Switches Explosion proof reed non-contact switches monitor the status of guarding doors in petro-chemical and food applications with explosive atmospheres. Based on reed

More information

Intrinsic Safety Solenoid Valves :-

Intrinsic Safety Solenoid Valves :- Intrinsic Safety Solenoid Valves :- Intrinsic safety valves can be used for applications that require similar explosion class/ignition degree to d2g4 or Exd II BT5 type (explosion-proof enclosure construction).

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The

More information

CUSTOMS UNION COMPLIANCE CERTIFICATE No. TC RU C-GB.MH04.B Series RU No

CUSTOMS UNION COMPLIANCE CERTIFICATE No. TC RU C-GB.MH04.B Series RU No EAC COMPLIANCE CERTIFICATE No. TC RU C-GB.MH04.B.00286 Series RU No. 0207965 AUTHORITY FOR CERTIFICATION of products of Research and Development Centre TECHNOPROGRESS, accreditation certificate No. РОСС

More information

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O****** Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O****** CSA 14.2662675 Ex ia IIC T6 Ga, Gb 0044 Document ID: 48924 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical

More information

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or

More information

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2 Compliance with EN60079-15: 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2 RJ11FTVX series: rugged and sealed RJ11/12 connectors Report Prepared by : Amphenol Socapex

More information

SET-2000 Oil/Sludge 12 VDC

SET-2000 Oil/Sludge 12 VDC Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 12.2.2015 Internet: www.labkotec.fi 1/14 SET-2000 Oil/Sludge 12 VDC Alarm Device for Oil Separators with

More information

Certificate No.: lecex BVS X issue No.:1 Certificate history: Issue No. 1 ( ) Status:

Certificate No.: lecex BVS X issue No.:1 Certificate history: Issue No. 1 ( ) Status: INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the lecex Scheme visit www.iecex.com Certificate No.: lecex BVS 12.0057X issue No.:1

More information

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt Airo Wireless Intrinsically Safe White Paper Written By: David Schmitt Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection certification for safe operation with electronic

More information

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0. Selection of Explosion Protected Equipment for Hazardous Locations Compiled by: Pieter Coetzee ZONE 2 ZONE 0 ZONE 1 Be safe be Ex Contents Introduction Occupational Health and Safety Act. (Act 85 of 1993)

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR 7 783 DETACTOGYR Flame Safeguard The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil or gas burners or

More information

C 319/6 Official Journal of the European Union

C 319/6 Official Journal of the European Union C 319/6 Official Journal of the European Union 5.11.2013 Commission communication in the framework of the implementation of the Directive 94/9/EC of the European Parliament and the Council of 23 March

More information

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION Special Safety Instruction en RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION Contents TankRadar Pro European ATEX Directive Information............................... 2 ATEX marking and Ex Certification

More information

OilSET-1000 (12 VDC)

OilSET-1000 (12 VDC) Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 Internet: www.labkotec.fi 20.03.2009 1/11 OilSET-1000 (12 VDC) Oil Separator Alarm Device Copyright 2009

More information

MAGNASPHERE L2 HSS Technology

MAGNASPHERE L2 HSS Technology MAGNASPHERE has Created the L2 Series HSS High Security Sensor The Next Generation Sensors That Meet UL 634 Level 2 High Security Standards for IFs, Safes and Vaults and All Other High Level Secure Applications.

More information

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 335/02)

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 335/02) C 335/10 EN Official Journal of the European Union 9.10.2015 Commission communication in the framework of the implementation of Directive 94/9/EC of the European Parliament and of the Council of 23 March

More information

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor DSF xx15.xx xhv Ex-Atex Product ID Type # Product # Drawing # DSF 1215.01 SHV Ex-atex (5m) 304Z-05197 113216 DSF 1415.01 AHV Ex-atex S148 304Z-05256 113351 DSF 1615.01 SHV Ex-atex (5m) 304Z-05196 113214

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for ru les and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: Current issue No.:1

More information

Instruction manual 640 Securiterre

Instruction manual 640 Securiterre Instruction manual 640 Securiterre Instruction manual 640 Securiterre April 2014 Part no. 4417571 Rev. 5 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701100 Fax : +31 15 2701111 E-mail

More information

SUPPLEMENT REPORT No.: XPL/13600/

SUPPLEMENT REPORT No.: XPL/13600/ (Pty) Ltd Certex Appointed Ex Laboratory Reg No: 1999/027771/07 Government Approved Test Laboratory (Previously AIA) T0104 7 Spanner rd, PO Box 467 Tel: +27 (11) 316 4601 Olifantsfontein Fax: +27 (11)

More information