1 CLASS PROGRAMME Type approval DNVGL-CP-0401 Edition February 2016 The electronic pdf version of this document, available free of charge from is the officially binding version.

2 FOREWORD DNV GL class programmes contain procedural and technical requirements including acceptance criteria for obtaining and retaining certificates for objects and organisations related to classification. February 2016 Any comments may be sent by to This service document has been prepared based on available knowledge, technology and/or information at the time of issuance of this document. The use of this document by others than DNV GL is at the user's sole risk. DNV GL does not accept any liability or responsibility for loss or damages resulting from any use of this document.

3 CHANGES CURRENT This is a new document. Changes - current Class programme DNVGL-CP Edition February 2016 Page 3

4 CONTENTS Changes current... 3 Contents Section 1 General Introduction Documentation...5 Section 2 Product Requirements Design requirements Test requirements...7 Section 3 Testing requirements Table of tests...9 Changes historic...11 Class programme DNVGL-CP Edition February 2016 Page 4

5 SECTION 1 GENERAL 1 Introduction 1.1 Objective The objective of this class programme (CP) is to describe the type approval (TA) scheme for electric high voltage cables. For a description of the Society's type approval scheme in general and further information on general conditions and procedures for obtaining the Society's TA certificate, see the Society's document DNVGL CP 0338 Type approval scheme. The procedures and requirements described in this CP are applicable for obtaining DNV GL TA certificate based on requirements given in: DNV GL rules for classification - Ships RU SHIP Pt.4 Ch.8 Electrical installations DNV GL offshore standard OS D201 Electrical installations. Section 1 Guidance note: This class programme is not applicable for obtaining EU marine equipment directive (MED) certificates. Visit for information on MED certification. ---e-n-d---o-f---g-u-i-d-a-n-c-e---n-o-t-e Scope This CP gives a description of the procedures and requirements related to documentation, design and type testing applicable for TA of electric high voltage cables. This CP does not set the design requirements to the electric high voltage cables. TA is based on compliance with design requirements given in the rules and/or other regulations and standards. The CP describes the applicable design requirements and how to document compliance with the requirements in order to obtain a TA certificate for the equipment. This includes, where relevant, technical requirements for how the type tests shall be performed. 1.3 Application DNV GL Rules RU SHIP Pt.4 Ch.8 require that electric high voltage cables are type approved by the Society, and TA in accordance with this CP is thus mandatory for equipment to be installed on DNV GL classed vessels. A TA certificate in accordance with this CP will confirm compliance with the requirements in the rules as specified in [1.1]. The TA certificate will not confirm compliance with requirements in other parts of the rules. In case additional requirements in other parts of the rules shall be covered by the TA certificate, this shall be specified in the application for TA and will be stated in the TA certificate. 2 Documentation For TA of electric high voltage cables the following documentation shall be submitted: 1) Data sheet(s) 2) Main drawings of all different cable construction covered by the type approval, showing conductors and the different layers. 3) References to design standards, rules, specifications etc. 4) Specification of applied materials. 5) Test results (from tests already carried out, if any). Class programme DNVGL-CP Edition February 2016 Page 5

6 6) Applicant's proposal to type test and routine test. 7) Documentation of reliability and endurance on board ships and mobile offshore units, if any. 8) 1) Special operational limitations. 9) 1) List of the cables covered by the type approval giving the following information's for each variant: 10) 1) number of cores conductor cross section (mm²) and number of strands insulation thickness (mm) fillers/bedding/inner covering thickness (mm) inner/outer sheath thickness (mm) diameter of braiding wires (mm) overall diameter max.-min. (mm) Construction details: voltage class: 3.6/6 kv, 6/10 kv, 8.7/15 kv, 12/20 kv, 18/30 kv conductors: Class 2 or class 5. Stranded copper conductor screening insulation material: EPR, HEPR or LPE inner/outer sheath material: ST2, SHF1, SE, SH, SHF2 or SHF2 Mud metal covering: Braid or armour made of galvanised. steel, bronze or copper material outer braid/armour if any. Special properties, if any (watertight, fire resistant etc.): 11) Flame retardant IEC Fire resistance EC /2 or IEC Low Halogen free IEC Halogen free IEC Fluorine content IEC cl.45 Low smoke IEC /2 Offshore cables Mud resistance NEK 606 Cold bend (-40 C) and impact (-35 C) CSA C22.2 No. 03 Cold bend (-40 C) App.E. 1.2 and Cold impact (-35 C) App.E. 2 and UV resistant ISO or UL 1581 Toxicity index IEC cl ) Test programme, which as a minimum includes the elements for type testing, Sec.3. The test programme shall refer to the relevant IEC standards for each test. 13) Application for type approval form 90.01a. Note: 1) These informations shall be stated in the Application form no a Section 1 Class programme DNVGL-CP Edition February 2016 Page 6

7 SECTION 2 PRODUCT REQUIREMENTS 1 Design requirements 1.1 General requirements The electric high voltage cables shall comply with the relevant requirements of the following publications in its latest edition including amendments: DNV GL rules for classification Ships RU SHIP Pt.4 Ch.8 Sec.9 DNV GL rules for classification - HSLC+Ship RU HSLC + SHIP Pt.4 Ch.8 DNVGL Offshore standards OS D101 : General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications IEC : Insulating and sheathing materials for shipboard and offshore units, power, control, instrumentation and telecommunication cables IEC : Single- and three-core power cables with extruded solid insulation for rated voltages 6 kv (Um = 7,2 kv) up to 30 kv (Um = 36 kv). Section Special properties IEC : Apparatus Fire alone at a flame temperature of at least 750 C IEC : Procedures and requirements Cables of rated voltage up to and including 0,6/1 kv IEC : Test method for fire with shock at a temperature of at least 830 C for cables of rated voltage up to and including 0,6/1,0 kv and with an overall diameter exceeding 20 mm IEC : Test for vertical flame propagation for a single insulated wire or cable - Apparatus. IEC : Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kw premixed flame. IEC : Test for vertical flame propagation for a single insulated wire or cable Procedure for determination of flaming droplets/particles. IEC : Test on vertical flame spread of vertically-mounted bunched wires or cables - Apparatus. IEC : Test on vertical flame spread of vertically-mounted bunched wires or cables Category A. IEC : Determination of the amount of halogen acid gas. IEC : Determination of degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring ph and conductivity. IEC : Measurement of smoke density of cables burning under defined conditions Part 1: Test apparatus. IEC : Measurement of smoke density of cables burning under defined conditions Part 2: Test procedure and requirements. 2 Test requirements The testing is divided into: visual inspection electrical/mechanical tests. 2.1 Visual inspection By visual inspection, it shall be verified that the test sample is in conformity with the approved plans. Class programme DNVGL-CP Edition February 2016 Page 7

8 2.2 Electrical/mechanical tests The tests shall be according to the relevant parts of Sec.3 Table 1. Section 2 Class programme DNVGL-CP Edition February 2016 Page 8

9 SECTION 3 TESTING REQUIREMENTS 1 Table of tests Table 1 Table of tests Section 3 No. Tests Specification of tests TT RT Mandatory 1. Visual inspection 2. Conductor examination 3. Insulation thickness 4. Sheath thickness 5. Dimensions of metal covering 6. Overall diameters 7. Resistance of conductors 8. High voltage test /354, 9. Partial discharge test IEC /350, IEC Bending test IEC / Tan d measurement as function of voltage IEC / Tan d measurement as function of temperature IEC / Heating cycle test plus partial discharge test IEC / Impulse withstand test, followed by a power-frequency test IEC / Test for the behaviour at low temperature of ST2, SHF 1 and SHF 2 sheaths 16. Flame retardant test IEC , IEC , IEC Water tightness test for "watertight" cables 18. Electrical characteristics of insulating compounds IEC , Table Hot set test for insulations and sheaths 20. Mechanical properties of insulating before and after ageing / Mechanical properties of sheaths before and after ageing /360 Class programme DNVGL-CP Edition February 2016 Page 9

10 No. Tests Specification of tests TT RT 22. Compatibility test Test for the behaviour at high temperature of ST2, SHF 1 sheaths (pressure test) Test for the behaviour at low temperature of ST2, SHF 1 and SHF 2 sheaths Section Test for resistance to cracking of ST2 and SHF 1 sheaths (heat shock test) 26. Determination of hardness for HEPR and HF HEPR insulations 27. Determination of elastic modulus for HEPR insulations 28. Ozone resistance test for insulation and for sheaths 29. Oil immersion test for elastomeric sheaths 31. Test of the metallic coating of copper wires 32. Galvanising test for steel wires Optional 33. Flame retardant test on bunched wires or cables IEC , IEC , 35. Tests for electric cables under fire conditions Circuit integrity. Test shall be performed with nominal voltage IEC , 35. Test on gases evolved during combustion of materials from cables 1) IEC , IEC IEC cl Measurement of smoke density of cables burning under defined conditions IEC , IEC Offshore cables NEK TS Cold bend (-40 C) App.E. 1.2 and Cold impact (-35 C) App.E. 2 and UV resistant ISO or UL Toxicity index IEC cl. 44 1) This test shall be carried out on the non-metallic components of cables claimed to be halogen free TT = Type Test RT = Routine Test Class programme DNVGL-CP Edition February 2016 Page 10

11 CHANGES HISTORIC There are currently no historical changes for this document. Changes historic Class programme DNVGL-CP Edition February 2016 Page 11

12 DNV GL Driven by our purpose of safeguarding life, property and the environment, DNV GL enables organizations to advance the safety and sustainability of their business. We provide classification and technical assurance along with software and independent expert advisory services to the maritime, oil and gas, and energy industries. We also provide certification services to customers across a wide range of industries. Operating in more than 100 countries, our professionals are dedicated to helping our customers make the world safer, smarter and greener. SAFER, SMARTER, GREENER

DNVGL-CP-0399 Edition March 2016

DNVGL-CP-0399 Edition March 2016 CLASS PROGRAMME Type approval DNVGL-CP-0399 Edition March 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

DNVGL-CP-0402 Edition February 2016

DNVGL-CP-0402 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0402 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

DNVGL-CP-0407 Edition February 2016

DNVGL-CP-0407 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0407 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

DNVGL-CP-0398 Edition December 2015

DNVGL-CP-0398 Edition December 2015 CLASS PROGRAMME Type approval DNVGL-CP-0398 Edition December 2015 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

Low-voltage switchgear and controlgear - rated voltage does not exceed 1000V AC or 1500V DC

Low-voltage switchgear and controlgear - rated voltage does not exceed 1000V AC or 1500V DC CLASS PROGRAMME Type approval DNVGL-CP-0396 Edition December 2015 Low-voltage switchgear and controlgear - rated voltage does not exceed 1000V AC or 1500V DC The electronic pdf version of this document,

More information

Terminal lugs for LV power cables with aluminum conductors

Terminal lugs for LV power cables with aluminum conductors CLASS PROGRAMME Type approval DNVGL-CP-0409 Edition January 2018 Terminal lugs for LV power cables with aluminum conductors The content of this service document is the subject of intellectual property

More information

Glass fibre rovings - Non-metallic materials

Glass fibre rovings - Non-metallic materials CLASS PROGRAMME Type approval DNVGL-CP-0082 Edition December 2015 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

Coatings for protection of FRP structures with heavy rain erosion loads

Coatings for protection of FRP structures with heavy rain erosion loads CLASS PROGRAMME Type approval DNVGL-CP-0424 Edition May 2016 Coatings for protection of FRP structures with heavy rain erosion loads The content of this service document is the subject of intellectual

More information

Lloyd s Register Type Approval System Test Specification Number 3

Lloyd s Register Type Approval System Test Specification Number 3 Working together for a safer world Lloyd s Register Type Approval System Test Specification Number 3 July 2015 Performance Test Specification for Equipment to be used in Marine Applications: Electric Cables

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60092-350 Second edition 2001-06 Electrical installations in ships Part 350: Shipboard power cables General construction and test requirements Installations électriques à bord

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE Certificate No: TAE00000GG Revision No: 2 This is to certify: That the Data transmission cables and systems with type designation(s) MGD Cat 3, MGD Cat 5, Cat 5e, MGD cat 6, Cat

More information

Part 6 Additional class notations Chapter 6 Additional fire protection for passenger vessels

Part 6 Additional class notations Chapter 6 Additional fire protection for passenger vessels RULES FOR CLASSIFICATION Inland navigation vessels Edition December 2015 Part 6 Additional class notations Chapter 6 Additional fire protection for passenger vessels The content of this service document

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61892-4 First edition 2007-06 Mobile and fixed offshore units Electrical installations Part 4: Cables Commission Electrotechnique Internationale International Electrotechnical

More information

Shipboard incinerators with capacities up to 4000 kw

Shipboard incinerators with capacities up to 4000 kw STANDARD FOR CERTIFICATION No. 2.9 Approval Programmes Type Approval Programmes for Marine Equipment Directive (MED) No. 431.90 - MED A.1/2.7 Shipboard incinerators with capacities up to 4000 kw JANUARY

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Presley House Presley Way Crownhill Milton Keynes MK8 0ES United Kingdom Contact: Jeremy Hodge Tel: +44 (0) 1908 267300 Fax: +44 (0) 1908

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60092-351 Third edition 2004-04 Electrical installations in ships Part 351: Insulating materials for shipboard and offshore units, power, control, instrumentation, telecommunication

More information

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

OFFSHORE CABLES.   Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain Top Cable Central Headquarters Leonardo Da Vinci, number 1 08191 Rubí (Barcelona) Spain OFFSHORE CABLES Tel +4 9 586 21 78 +4 9 586 21 68 Fax +4 9 586 21 65 sales@topcableoffshoremarine.com http://www.topcableoffshoremarine.com

More information

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax: STANDARD FOR CERTIFICATION No. 2.9 RADAR REFLECTOR JANUARY 2003 Veritasveien 1, N-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD is an autonomous and independent Foundation with

More information

MARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

MARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax: STANDARD FOR CERTIFICATION No. 2.9 MARINE GYRO COMPASS JANUARY 2003 Veritasveien 1, N-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD is an autonomous and independent Foundation

More information

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd. Flexflame Arctic Grade Cables for Extreme Conditions Photo: Sakhalin Energy Investement Company Ltd. Linking the future Draka Norsk Kabel is a part of Prysmian Group, a worldwide leader in the cable industry.

More information

Indicators for Rudder Angle, Rate of Turn, Propeller Shaft Revolution and Propeller Pitch

Indicators for Rudder Angle, Rate of Turn, Propeller Shaft Revolution and Propeller Pitch STANDARD FOR CERTIFICATION No. 2.9 TYPE APPROVAL PROGRAMME NO. 844.40 - MED A1/4.20-4.21-4.22-4.9 Indicators for Rudder Angle, Rate of Turn, Propeller Shaft Revolution and Propeller Pitch FEBRUARY 2012

More information

SIMPLIFIED VOYAGE DATA RECORDER (S-VDR)

SIMPLIFIED VOYAGE DATA RECORDER (S-VDR) STANDARD FOR CERTIFICATION No. 2.9 SIMPLIFIED VOYAGE DATA RECORDER (S-VDR) APRIL 2009 Veritasveien 1, NO-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD (DNV) is an autonomous and

More information

High Performance LSZH Fire Resistant Cable

High Performance LSZH Fire Resistant Cable High Performance LSZH Fire Resistant Cable www.cavicel.com 104/2 FIRECEL SR 114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60092-376 Second edition 2003-05 Electrical installations in ships Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) Installations électriques à bord

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60840 Third edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages above 30 kv (U m = 36 kv) up to 150 kv (U m = 170 kv) Test methods

More information

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

Circuit Breakers JANUARY The electronic pdf version of this document found through   is the officially binding version STANDARD FOR CERTIFICATION No. 2.9 Approval Programmes Type Approval Programmes for EU recognised organisation Mutual Recognition (MR) No. MR-E001 Circuit Breakers JANUARY 2013 The electronic pdf version

More information

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables - MARINE CABLES Your Power Partner on the Seas INTRODUCTION We, a member of the Al-Bahja Group of Companies, are an ISO:900:2008 BASEC, UK certified integrated quality producer of LV and MV Cables, Wires&

More information

PRODUCT CATALOGUE Norröna

PRODUCT CATALOGUE  Norröna PRODUCT CATALOGUE Norröna WWW.SCANKAB.COM Table of contents MARINE AND OFFSHORE CABLES 1 TOXFREE XZ1-K (AS) - 0.6/1 kv 1 TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V 5 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 -

More information

Traction Cable Radox 3 GKW

Traction Cable Radox 3 GKW General Properties : Excellent high temperature, low temperature, ozone and weathering resistance, zero halogen, flame retardant, solder iron resistant, easily strippable, flexible. Application : Single

More information

Cable Ties JULY The electronic pdf version of this document found through is the officially binding version

Cable Ties JULY The electronic pdf version of this document found through  is the officially binding version p pproval roramms for U rcos orasato Mutual coto (M)No. 2.9 STANDARD FOR CERTIFICATION Approval Programmes Type Approval Programmes for EU recognised organisation Mutual Recognition (MR) No. MR-E012 Cable

More information

SOUND RECEPTION SYSTEM

SOUND RECEPTION SYSTEM STANDARD FOR CERTIFICATION No. 2.9 SOUND RECEPTION SYSTEM APRIL 2009 Veritasveien 1, NO-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD (DNV) is an autonomous and independent foundation

More information

QUALITY THROUGH EXPERIENCE

QUALITY THROUGH EXPERIENCE QUALITY THROUGH EXPERIENCE Brief History of ÜNTEL Established in 1972 Partnership of Ünlü and Günan families since then 40 years of manufacturing experience with an extensive production range for various

More information

(Notices) EUROPEAN COMMISSION

(Notices) EUROPEAN COMMISSION 14.8.2012 Official Journal of the European Union C 245/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework

More information

Shipboard & Offshore Cables

Shipboard & Offshore Cables Shipboard & Offshore Cables Shipboard & Offshore Cables Páge Introduction 3 Power Cables XL / XL-FR 5 XC4L / XC4L-FR 6 XLC4L / XLC4L-FR 7 Instrumentation cables XHL / XHL-FR 8 XOL / XOL-FR 9 XHC4L / XHC4L-FR

More information

Single core cables with reduced wall thickness

Single core cables with reduced wall thickness Product description: RADOX 4 GKW -AX 1800V M Nominal voltage: Hazard level: Single core cables with reduced wall thickness 1800 / 3000 V AC M (extra low temperature, extra oil and extra fuel resistant)

More information

GROUNDING AVOIDANCE SYSTEM (GAS)

GROUNDING AVOIDANCE SYSTEM (GAS) STANDARD FOR CERTIFICATION No. 2.9 GROUNDING AVOIDANCE SYSTEM (GAS) JANUARY 2003 Veritasveien 1, N-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD is an autonomous and independent

More information

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation CPR Construction Products Regulation Index Construction Products Regulation... 3 What is the Construction Products Regulation (CPR)... 4 What is the objective of the CPR... 4 Who does the application of

More information

APRIL 2010 ELECTRICAL EQUIPMENT STANDARD FOR CERTIFICATION DET NORSKE VERITAS. No. 2.9 Type Approval Programme No

APRIL 2010 ELECTRICAL EQUIPMENT STANDARD FOR CERTIFICATION DET NORSKE VERITAS. No. 2.9 Type Approval Programme No STANDARD FOR CERTIFICATION No. 2.9 Type Approval Programme No. 6-800 ELECTRICAL EQUIPMENT APRIL 2010 DET NORSKE VERITAS Veritasveien 1, NO-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11

More information

THE TRUE FIRE SURVIVAL CABLE

THE TRUE FIRE SURVIVAL CABLE 25 YEAR THE TRUE FIRE SURVIVAL CABLE WARRANTY In 1989 we developed a unique process of manufacturing continuous mineral insulated copper cables. THE TRUE FIRE SURVIVAL CABLE We are the only UK manufacturer

More information

Caledonian. FIREFLIX ire Resistant Coaxial Cables

Caledonian. FIREFLIX ire Resistant Coaxial Cables Caledonian FIREFLIX ire Resistant Coaxial Cables table OF COntents Fire resistant Coaxial Cables Fire Resistant RG59 B/U coaxial cables...25 Fire Resistant RG6 A/U coaxial cables...28 Fire Resistant RG6

More information

Havells Fire Survival Cables

Havells Fire Survival Cables Fire Survival Cables Designed for Critical Installation of National Importance Airports / Thermal Power Plants Metro Rail Projects / Rail Terminals / Nuclear Interstate Bus Terminals / Installation Prone

More information

Power Control Cable Iec

Power Control Cable Iec POWER CONTROL CABLE IEC 60502 1 PDF - Are you looking for power control cable iec 60502 1 Books? Now, you will be happy that at this time power control cable iec 60502 1 PDF is available at our online

More information

Üntel is ready for CPR

Üntel is ready for CPR 2016 Üntel is ready for CPR Hakan Kubas Marketing Manager 01.11.2016 Construction Products Regulation What is the CPR? The Construction Products Regulation (CPR) lays down conditions for the placing or

More information

HIGH-VOLTAGE CABLE TESTING: TYPE TEST EXPERIENCES AND NEW INSIGHTS INTO PRE-QUALIFICATION

HIGH-VOLTAGE CABLE TESTING: TYPE TEST EXPERIENCES AND NEW INSIGHTS INTO PRE-QUALIFICATION HIGH-VOLTAGE CABLE TESTING: TYPE TEST EXPERIENCES AND NEW INSIGHTS INTO PRE-QUALIFICATION Edwin Pultrum, Wouter Sloot, Joaquin Fernandez, René Smeets Presenter: René Smeets PhD, FIEEE Innovation manager

More information

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive Page 1/8 Illustrations Principle diagram See enlarged drawings at the end of document Product specification mini-breakout installation cable U-VQ(ZN)H laser-optimized, bend insensitive fiber UV-resistant,

More information

Issued to DISTRIBUIDORA INTERNACIONAL CARMEN, S.A -DICSA- Zaragoza Zaragoza, Spain

Issued to DISTRIBUIDORA INTERNACIONAL CARMEN, S.A -DICSA- Zaragoza Zaragoza, Spain Certificate No: TAP00000MD This is to certify: That the Flexible Hoses of Non-Metallic Material with Permanently Fitted Couplings with type designation(s) Trale/Triagle hoses with DICSA stainless/carbon

More information

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive Illustrations Principle diagram Page 1/7 Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or stranded loose tube bend insensitive fiber

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ISO/IEC 17065:2012 to provide product conformity certification Presley Way Crownhill Milton Keynes MK8 0ES Contact: Tracie Hunter Tel: +44 (0)1908 267300 Fax: +44 (0)1908 267255 E-Mail: mail@basec.org.uk

More information

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V PHOTOVOLTAIC CABLES PHOTOVOLTAIC CABLES INDEX n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1500V....................... 2-3 n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1000V.......................

More information

fire resistant cables

fire resistant cables Building Technology fire resistant cables Special electrical and optical cables www.tecnikabel.com Special electrical and optical cables 2 INTRODUCTION Structured cabling solutions. Tecnikabel can provide

More information

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1 Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors

More information

Photovoltaic Cables EN H1Z2Z2-K

Photovoltaic Cables EN H1Z2Z2-K Photovoltaic Cables EN 50618 H1Z2Z2-K COMPANY PROFILE Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different

More information

GUIDE TO APPROVAL OF RETROFIT BALLAST WATER MANAGEMENT SYSTEM INSTALLATIONS

GUIDE TO APPROVAL OF RETROFIT BALLAST WATER MANAGEMENT SYSTEM INSTALLATIONS GUIDE TO APPROVAL OF RETROFIT BALLAST WATER MANAGEMENT SYSTEM INSTALLATIONS September 2016 DNV GL Approval Ship and Offshore Environmental Protection bwm@dnvgl.com DNV GL Headquarters, Veritasveien 1,

More information

SHOP PRIMERS FOR CORROSION PROTECTION OF STEEL PLATES AND SECTIONS

SHOP PRIMERS FOR CORROSION PROTECTION OF STEEL PLATES AND SECTIONS STANDARD FOR CERTIFICATION No. 2.9 SHOP PRIMERS FOR CORROSION PROTECTION OF STEEL PLATES AND SECTIONS OCTOBER 2009 Veritasveien 1, NO-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD

More information

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB. Certificate No 077b Certificate No 517b > Prysmian FP400 is the original fire resistant armoured cable providing an easy to install and terminate, robust fire resistant wiring system. In addition to maintaining

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61138 Second edition 1994-04 Cables for portable earthing and short-circuiting equipment This English-language version is derived from the original bilingual publication by leaving

More information

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour. 67 POWERFLEX RV-K POWERFLEX RV-K Industrial flexible cable for power transmission. 1 IEC 60502-1 - UNE 21123-2 DESIGN 1. Conductor 2 Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.

More information

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation. Technical Data Sheet BETAflam Solar 125 flex UL 4703 Description Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60076-11 First edition 2004-05 Power transformers Part 11: Dry-type transformers This English-language version is derived from the original bilingual publication by leaving out

More information

GLASS FIBRE REINFORCEMENTS

GLASS FIBRE REINFORCEMENTS STANDARD FOR CERTIFICATION No. 2.9 GLASS FIBRE REINFORCEMENTS OCTOBER 2009 Veritasveien 1, NO-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD (DNV) is an autonomous and independent

More information

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION Fire alarm cables for highest safety requirements TRADITION INNOVATION PASSION Datwyler Datwyler Cabling Solutions is an internationally operating company with its headquarters in Switzerland and affiliates

More information

FIRE RESISTANT CABLES FP400

FIRE RESISTANT CABLES FP400 FIRE RESISTANT CABLES FP400 FIRE RESISTANT CABLES FP400 BS7846-F2 CABLE CHARACTERISTICS FP400 APPROVALS INSTALLATION Certificate No 077b Certificate No 517b > Prysmian FP400 is the original fire resistant

More information

Fire Safety Fire Resistant Building Components

Fire Safety Fire Resistant Building Components Fire Safety Fire Resistant Building Components NBN 713-020 1968 Fire fighting - Fire performance of building materials and products - Fire resistance of building materials NBN 713-020/A1 1982 Protection

More information

Electrical test. Determining resistance of conductors by means of using DC four-wire connection measurement

Electrical test. Determining resistance of conductors by means of using DC four-wire connection measurement Nr. Material or Product Type of activity Internal reference number 1 Cables of rated voltage up to Electrical test Determining resistance of conductors by means of using DC four-wire connection measurement

More information

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Flame Retardant Overall Screened Instrumentation Cables (multicore) Flame Retardant Overall Screened Instrumentation Cables (multicore) RE-2X(St)H RE-2X(St)HSWAH LSZH Outer Sheath Tinned Copper Drain Wire LSZH Inner Sheath XLPE Insulation Plain Annealed Copper Aluminium/polyester

More information

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. Product Specification 108-93018 25/Aug/2011 Rev H Copper LAN cable 1. SCOPE 1.1. Content This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. 2. APPLICABLE DOCUMENTS

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60227-7 Edition 1.1 2003-04 Edition 1:1995 consolidated with amendment 1:2003 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V Part 7: Flexible

More information

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation)

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation) C 173/162 EN Official Journal of the European Union 13.5.2016 CORRIGENDA Corrigendum to Commission communication in the framework of the implementation of Directive 2006/95/EC of the European Parliament

More information

WORLDWIDE CABLE EXPERTS

WORLDWIDE CABLE EXPERTS WORLDWIDE CABLE EXPERTS An introduction to our cable testing and certification services CORPORATE BROCHURE PAGE I TWO Contents 2 Introducing BASEC 3 What we do 4 Management Systems Certification 5 Product

More information

Part 4 Systems and components Chapter 5 Control and Monitoring Systems

Part 4 Systems and components Chapter 5 Control and Monitoring Systems RULES FOR CLASSIFICATION Inland navigation vessels Edition December 2015 Part 4 Systems and components Chapter 5 The content of this service document is the subject of intellectual property rights reserved

More information

Fire Resistant Cables

Fire Resistant Cables Fire Resistant Cables Ducab (Abu Dhabi) Factory P.O. Box 9171, Abu Dhabi, UAE Tel: (971-2) 502 7777 Fax: (971-2) 502 7888 email: ducab@ducab.com Ducab Connect P.O. Box 11529, Dubai, United Arab Emirates

More information

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+) Page 1 / 7 Construction and tests. Standards: UNE 211025 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº 305/2011: Reaction to

More information

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 1: General requirements. Australian/New Zealand Standard

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 1: General requirements. Australian/New Zealand Standard AS/NZS 61386.1:2015 Australian/New Zealand Standard Conduit systems for cable management Part 1: General requirements Superseding AS/NZS 2053.1:2001 AS/NZS 61386.1:2015 AS/NZS 61386.1:2015 This joint Australian/New

More information

The Quality Connection. BETAflam Fire Resistant Safety Cables

The Quality Connection. BETAflam Fire Resistant Safety Cables The Quality Connection BETAflam Fire Resistant Safety Cables BETAflam Contact Your personal customer number To offer you a more efficient service, we kindly ask you to mention your personal customer number

More information

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02)

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02) C 298/14 EN Official Journal of the European Union 8.9.2017 Commission communication in the framework of the implementation of Directive 2014/35/EU of the European Parliament and of the Council on the

More information

ENHANCED FIRE PERFORMANCE CABLE

ENHANCED FIRE PERFORMANCE CABLE FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Glass Fibre Tape / Tinned Copper Circuit Protective Conductor / Double Layer of Copper/Polyester

More information

HYUNDAI HEAVY INDUSTRIES CO., LTD.

HYUNDAI HEAVY INDUSTRIES CO., LTD. Certificate No.: 52700-2009-AE-KOR-RvA Initial Certification Date: 07 March, 1997 Valid: 16 March, 2015 16 March, 2018 This is to certify that the management system of CO., LTD. 1000, Bangeojinsunhwando-ro,

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE Certificate No: TAE00001BS Revision No: 1 This is to certify: That the Frequency Converter with type designation(s) SINAMICS S120 Cabinet s, Liquid Cooled, Application Marine

More information

Sergey Gribanov Head of Technical Service, Germany

Sergey Gribanov Head of Technical Service, Germany MARITIME SHARING OPERATIONAL EXPERIENCE TANKERS Tanker Operator conference, Hamburg, 18.10.2016 Sergey Gribanov Head of Technical Service, Germany SAFER, SMARTER, GREENER AGENDA The DNV GL way to gather

More information

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2 FLAME-X 950 TELE-FONIKA KABLE SA (DMCC Branch). Table of Contents is the Regional Middle East Sales Office of Tele-Fonika Kable S.A. from Poland, 4-th largest manufacturer of electric cables and wires

More information

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD INTERIM EUROPEAN I-ETS 300 644 TELECOMMUNICATION June 1997 STANDARD Source: ETSI TC-TM Reference: DI/TM-01021 ICS: 33.020 Key words: Fibre, cable, optical, transmission Transmission and Multiplexing (TM);

More information

Flexible Power Cable DLO

Flexible Power Cable DLO 37-119 Flexible Power Cable DLO 2000 Volts 90 C Diesel Locomotive Cable Limited Smoke (Sizes 2/0 and higher) EP/CPE RHH, RHW-2 Flexible-stranded, tin-coated annealed copper Flame retardant, oil and sunlight

More information

ISO INTERNATIONAL STANDARD. Determination of the resistance to jet fires of passive fire protection materials Part 1: General requirements

ISO INTERNATIONAL STANDARD. Determination of the resistance to jet fires of passive fire protection materials Part 1: General requirements INTERNATIONAL STANDARD ISO 22899-1 First edition 2007-12-01 Determination of the resistance to jet fires of passive fire protection materials Part 1: General requirements Détermination de la résistance

More information

For compliance with Resolution MEPC.174(58), the Certificate is issued on behalf of the Norwegian Maritime Authority.

For compliance with Resolution MEPC.174(58), the Certificate is issued on behalf of the Norwegian Maritime Authority. Certificate No: TAP000006X Revision No: 1 This is to certify: That the Ballast Water Management System with type designation(s) Optimarin Ballast System, Optimarin Ballast System Ex Issued to Optimarin

More information

Accumulated Battery JULY The electronic pdf version of this document found through is the officially binding version

Accumulated Battery JULY The electronic pdf version of this document found through   is the officially binding version p pproval roramms for U rcos orasato Mutual coto (M)No. 2.9 STANDARD FOR CERTIFICATION Approval Programmes Type Approval Programmes for EU recognised organisation Mutual Recognition (MR) No. MR-E008 Accumulated

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE Certificate No: TAA00001CD This is to certify: That the Programmable Controller with type designation(s) SIPLUS Series Issued to Siemens AG Fürth, Germany is found to comply with

More information

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE Carol Harris, EMEA Product Manager WHITE PAPER Molex Connected Enterprise Solutions EXECUTIVE SUMMARY Combustible construction materials

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60245-8 Edition 1.1 2004-01 Edition 1:1998 consolidated with amendment 1:2003 Rubber insulated cables Rated voltages up to and including 450/750 V Part 8: Cords for applications

More information

Wires, Cables, Cords and Adhesive Tapes

Wires, Cables, Cords and Adhesive Tapes 702-CRC-006-E Revision: 08 Page: 1/34 Elaborated by: Douglas Ferreira Checked by: Nelson A. Coelho Approved by: Arnaldo Barbulio Filho Approval date: 23\08\13 1 OBJECTIVE This document presents the complementary

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD IEC 60092-306 Edition 4.0 2009-11 Electrical installations in ships Part 306: Equipment Luminaires and lighting accessories IEC 60092-306:2009(E) THIS PUBLICATION IS COPYRIGHT PROTECTED

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE Certificate No: TAA00000W5 Revision No: 2 This is to certify: That the Control and Monitoring System with type designation(s) K-Chief 700 and K-Safe Issued to KONGSBERG MARITIME

More information

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES CORFLEX TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES INDEX Instrumentation Cables - Pairs and Triads (0V*)... 2 - The Original MC-HL Technology In 1958 Canada Wire and Cable, which s now part of Nexans,

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60770-3 First edition 2006-04 Transmitters for use in industrial-process control systems Part 3: Methods for performance evaluation of intelligent transmitters IEC 2006 Copyright

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60189-2 Fourth edition 2007-05 Low-frequency cables and wires with PVC insulation and PVC sheath Part 2: Cables in pairs, triples, quads and quintuples for inside installations

More information

Catalogue Telecommunication Cables INTRODUCCIÓN

Catalogue Telecommunication Cables INTRODUCCIÓN Catalogue Telecommunication Cables INTRODUCCIÓN Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Conductores Tecnológicos S.A.

More information

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Product Specification CAT 6 UNSHIELDED PATCH CORDS Product 108-93017 Specification 23/Nov/06 Rev. A CAT 6 UNSHIELDED PATCH CORDS 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for NETCONNECT

More information

Survey of electrical equipment installed in hazardous areas on tankers

Survey of electrical equipment installed in hazardous areas on tankers (June 2015) Survey of electrical equipment installed in hazardous areas on tankers 1. Application The recommendations in this document apply for survey of electrical installation in hazardous areas on

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 25762 First edition 2009-07-01 Plastics Guidance on the assessment of the fire characteristics and fire performance of fibre-reinforced polymer composites Plastiques Lignes directrices

More information

Catalogue Power Cables

Catalogue Power Cables Catalogue Power Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Power

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60754-3 Edition 1.0 2018-03 Test on gases evolved during combustion of materials from cables Part 3: Measurement of low level of halogen content by ion chromatography INTERNATIONAL