1 RECOGNIZED COMPONENT Constructional Data Report (CDR) 1.0 Reference and Address Report Number SHA-001 Original Standard(s) Power Units Other Than Class 2 UL 1012 Eighth Edition Dated November 9, 2010 containing Revisions through and including May 14, 2014 General Use Power Supplies CSA C22.2 No Dated September 2001, Reaffirmed 2011 Applicant Manufacturer Address 5F., No.8, Alley 11, Lane 327, Sec. 2, Chung San Road, Chung Ho, Taipei County Address 2F, No.14, Lane 327, Sec. 2, Chung San Road, Chung Ho, Taipei County Country Contact Phone FAX Taiwan Mr. K.C. Huang kc@ieeeg.com Country Contact Phone FAX Taiwan Ms. S.H. Huang shhuang@ieeeg.com Page 1 of 25

2 2.0 Product Description Product Brand name Switching Power Supply AMC Page 2 of 25 Description Models Model Similarity Ratings Other Ratings Conditions of Acceptability The product covered by this report is switching mode power supplies with no power supply provided, it shall be connected to VAC 50/60Hz supply source indirectly. SPS100 NA Input: Vac, 50/60Hz, 2.5A Output: 12Vdc, 10A NA The products covered in this Report are incomplete in construction features or limited in performance capabilities and are intended for use and evaluation in other products. Consideration should be given to the following when the component is used in or with another product. 1) A suitable enclosure that complies with CSA Enclosure 2 (Dripproof) of CSA Standard C22.2 No. 94, should be provided, and the suitability of the enclosure should be considered during evaluation end-use product. 2) The product is only intended for use in a CONTROLLED ENVIRONMENT

3 3.0 Product Photographs Photo 1 - Front view Page 3 of 25 1 Photo 2 - Back view 12

4 3.0 Product Photographs Page 4 of 25 Photo 3 - Internal view 2 Photo 4 - PCB 8 7

5 3.0 Product Photographs Page 5 of 25 Photo 5 - PCB Photo 6 - Back view of PCB 10

6 3.0 Product Photographs Page 6 of 25 Photo 7 - Transformer 9

7 Page 7 of Critical Components Photo # Item no. 1 Name Manufacturer/ trademark 2 Type / model 2 Technical data and securement means Mark(s) of conformity Enclosure 3 2 Appliance inlet Nan Ya Plastics (Hui Zhou) Corp Ltd 4410G4 Yueqing Yanhui DB-14 Electronic Co Ltd Zhejiang Leci Electronics DB-14 Co Ltd Various CONQUER ELECTRONICS CO LTD Various Rated V-0, RTI(150, 130, 130), HWI=0, HAI=3, Min. thick 1.5mm, secured by screws. (E235269) Rated AC250V, 10A, IEC 320 Config: C14. (E334847) Rated AC250V, 10A, IEC 320 Config: C14. (E302229) Rated AC250V, 10A, IEC 320 Config: C14. curus UL, CSA PTU T5A, 250V, (E82636) curus Fuse VDR (VR2) (optional) X Capacitor (CX1, CX2) Y capacitor (CY1, CY2) SHENZHEN LANSON ELECTRONICS CO LTD HONG HU BLUELIGHT ELECTRONIC CO LTD XC ELECTRONICS (SHENZHEN) CORP LTD Thinking Electronic Industrial Co Ltd Shantou High-New Technology Developmnt Zone Songtian Enterprise Co Ltd Shenzhen Surong Capacitors Co Ltd Shantou High-New Technology Developmnt Zone Songtian Enterprise Co Ltd Liaoning Diya Capacitor Co Ltd Europtronic (Taiwan) Industrial Corp Shantou High-New Zone Songtian Enterprise Co., Ltd Hsuan Tai Electronics Co Ltd 3N T5A, 250V, (E221465) curus L3CT, L3T T5A, 250V, (E324232). curus 3T T5A, 250V, (E249609). curus TVR10471K, TVR10511K, TVR10561K, TVR10621K, TVR10681K, TVR14471K, TVR14511K, TVR14561K, TVR14621K, TVR14681K 10D471K, 10D511K, 10D561K, 10D621K, 10D681K, 14D471K, 14D511K, 14D561K, 14D621K, 14D681K MPX MPX MKP-X2 MPX2 Series CD CY Series Rated Min.300Vac. (E314979) Rated Min.300Vac. (E330837) Max. 0.47µF, Min. 275VAC, 100 C, X2 type; (E314875) Max. 0.47µF, Min. 275VAC, 100 C, X2 type; (E208107) Max. 0.47µF, Min. 275VAC, 100 C, X2 type; (E305002) Max. 0.47µF, Min. 275VAC, 100 C, X2 type; (E211347) Max. 1000pF, Min.400VAC, 125 C, Y1 type, 2 pieces. (E208107) Max. 1000pF, Min.400VAC, 125 C, Y1 type, 2 pieces. (E ) curus curus curus curus

8 Page 8 of Critical Components Photo # Item no. 1 Name Manufacturer/ trademark 2 Type / model 2 Technical data and securement means Yinan Don's Electronic Component Co Ltd Shantou High-New Zone Songtian Enterprise Co., Ltd CT81 CD Max. 1000pF, Min.400VAC, 125 C, Y1 type, 2 pieces. (E145038) Max. 2200pF, Min.400VAC, 125 C, Y1 type, 2 pieces. (E208107) Max. 2200pF, Min.400VAC, 125 C, Y1 type, 2 Mark(s) of conformity Y capacitor Hsuan Tai Electronics CY Series (CY3, CY4) Co Ltd pieces. (E ) curus Max. 2200pF, Yinan Don's Electronic CT81 Min.400VAC, 125 C, Y1 type, 2 Component Co Ltd pieces. (E145038) Bright Led Electronics Corp BPC-817 (Series) Dti=0.4mm, int.dcr=5.2mm, Ext.dcr=8.0mm, 100 C; (E236324) 4 8 Optical Sharp Corp Electronic isolators Dti=0.4mm, int.dcr=5.2mm, Components And PC817 (U2) Ext.dcr=8.0mm, 100 C; (E64380) Devices Div curus Dti=0.4mm, int.dcr=5.2mm, Shenzhen Orient ORPC-817 Ext.dcr=8.0mm, 100 C; (E Components Co Ltd (Series) ) 7 9 Transformer Shenzhen Anpinyuan Technology Co Ltd SUN1139B 6 10 PCB Various Various 2 11 Output wire Various 2 12 Quick connector Label (not 2 13 show) NOTES: SPT-2 or 2464 or 1185 Class 130 (B) electrical insulation systems, designated APY-01 (E ) certified UL 796, V-0, 130 C, 1.6mm thickness. See 5.0 curus 300V, 20AWG min., 60 C curus Various Various Width:4.8mm, with insulator curus Various Various certified UL 969, 85 C. curus 1) Not all item numbers are indicated (called out) in the photos, as their location is obvious. 2) Various means any type, from any manufacturer that complies with the "Technical data and securement means" and meets the "Mark(s) of conformity" can be used. 3) Indicates specific marks to be verified, which assures the agreed level of surveillance for the component. "NR" - indicates Unlisted and only visual examination is necessary. "See 5.0" indicates Unlisted components or assemblies to be evaluated periodically refer to section 5.0 for details.

9 Page 9 of Critical Unlisted CEC Components Transformer Spec. Photo # Item no. Name Manufacturer/Trademark Type / model 7 9 Transformer Shenzhen Anpinyuan Technology Co Ltd SUN1139B Electrical Rating: / Insulation class Component Standard used: Bobbin Chang Chun T375J UL 1012 Eighth Edition Dated November 9, 2010 containing Revisions through and including May 14, 2014 CSA C22.2 No Dated September 2001, Reaffirmed 2011 MATERIALS LIST Component Manufacturer Type/model Dimensions/thickness/assembly information Core Various Various Ferrite Phenolic, V-0,150 C, min Thick.:1.0mm, (E59481) B Tipple Insulation Wire Furukawa Electric Co Ltd TEX-B for secondary winding 130 C, reinforced insulation, (E206440) 3m Company Electrical Markets Div (Emd) 1350F C, (E ) Insulation tape Jingjiang Yahua Pressure Sensitive Glue Co Ltd PZ, CT, WF 130 C; (E165111) Symbio Inc C, (E50292 ) Varnish Hitachi Chemical Co., Ltd WP-2952F- 2G 130 C, (E72979 ) Margin tape Jingjiang Yahua Pressure Sensitive Glue PZ 130 C, (E165111) WINDING(S) RESISTANCE Winding Wire Size DC resistance Designation (AWG or mm 2 Wire Type Turns Volts Amps ) (Ω) +/- 10%: N1 Coil 0.55X6 TEX-B 6 / / / N5 Coil 0.3X4mm 2UEW 18 / / / N4 Coil 0.5x2 2UEW 43 / / / N3 Coil 0.3X4mm 2UEW 8 / / / N2 Coil 0.55X6 TEX-B 6 / / / VERIFICATION PROCESS Frequency: Annual Test Site: CEC Number of samples to test: 3 Test Name Test Parameters Winding resistance See resistance per winding above(check turn number). Apply voltage Between Test Voltage Test Time Dielectric Strength Primary to core s Primary to secondary s Secondary to core s Illustration for transformer spec.

10 Page 10 of Critical Features Recognized Component - A component part, which has been previously evaluated by an accredited certification body with restrictions and must be evaluated as part of the basic product considering the restrictions as specified by the Conditions of Acceptability. Listed Component - A component part, which has been previously Listed or Certified by an accredited Certification Organization with no restrictions and is used in the intended application within its ratings. Unlisted Component - A part that has not been previously evaluated to the appropriate designated component standard. It may also be a Listed or Recognized component that is being used outside of its evaluated Listing or component recognition. Critical Features/Components - An essential part, material, subassembly, system, software, or accessory of a product that has a direct bearing on the product s conformance to applicable requirements of the product standard. Construction Details - For specific construction details, reference should be made to the photographs and descriptions. All dimensions are approximate unless specified as exact or within a tolerance. In addition to the specific construction details described in this Report, the following general requirements also apply. 1. Spacing - In primary circuits, minimum spacings are maintained 3.2 mm through air and 6.4 over surfaces of insulating material between current-carrying parts of opposite polarity and between current-carrying parts and dead-metal parts. The spacings between field wiring terminals of opposite polarity or between the field wiring terminal and other uninsulated metal parts, not of the same polarity, are minimum 6.4 mm through-air and over-surface. The spacings between a Class 2 circuit and non-class 2 circuits, and accessible metal, and grounded metal shall not be less than 6.4 mm. 2. Mechanical Assembly - Components such as switches, fuseholders, connectors, wiring terminals and display lamps are mounted and prevented from shifting or rotating by the use of lockwashers, starwashers, or other mounting format that prevents turning of the component. 3. Corrosion Protection - All ferrous metal parts are protected against corrosion by painting, plating or the equivalent. 4. Accessibility of Live Parts - All uninsulated live parts in primary circuitry are housed within a metal and nonmetallic enclosure constructed with no openings other than those specifically described in Sections 4 and Grounding - All exposed dead-metal parts and all dead-metal parts within the enclosure that are exposed are connected to the grounding lead of the power supply cord. 6. Polarized Connection - NA 7. Internal Wiring - NA(no internal wire) 8. Circuit diagram - Refer to Illustration No. 2 for circuit diagram requiring verification during Field Representative Inspection Audits. 9. Markings - The product is marked on a labeling system as described in item No.14 of Section 4.0 as follows: manufacturer's name, brand name, model number, date of manufacturer, electrical ratings.refer to 7.0 Illustrations No.1 for details Cautionary Markings - None. 11. Installation, Operating and Safety Instructions - Instructions for installation and use of this product are provided by the manufacturer. Refer to Illustration No(s).4, 4a, 4b, 4c, 4d for details. 12. PWB layout - Refer to Illustration No. 3 for requiring verification during Field Representative Inspection Audits.

11 7.0 Illustrations Illustration 1- Label Page 11 of 25 Remark: 1. The control number and wording CONFORMS TO UL STD.1012 CERTIFIED TO CSA STD. C22.2 No " shall be at least 1.5 mm high. 2. The ETL & cetl logo shall not be less than 8 mm in width and 8 mm in height, the US, C and control number shall not be less than 2 mm in height. The CM shall not be less than 1mm in height."intertek"shall not less than 3 mm in height. 3. Date code of manufacture (Series No. ) (not shown): "Month/YYYY " represent the month and after four numbers"yyyy " represent the year.

12 7.0 Illustrations Illustration 2 - Circuit diagram Page 12 of 25

13 7.0 Illustrations Illustration 3 - PWB layout Page 13 of 25

14 7.0 Illustrations Illustration 4- Manual Page 14 of 25

15 7.0 Illustrations Illustration 4a- Manual (continued) Page 15 of 25

16 7.0 Illustrations Illustration 4b- Manual (continued) Page 16 of 25

17 7.0 Illustrations Illustration 4c- Manual (continued) Page 17 of 25

18 7.0 Illustrations Illustration 4d- Manual (continued) Page 18 of 25

19 Page 19 of Test Summary Evaluation Period to Project No SHA Sample Rec. Date 5-Aug-2015 Condition Prototype Sample ID Test Location Test Procedure Building No. 86, 1198 Qinzhou Road (North), Shanghai , P. R. China Testing Lab Determination of the result includes consideration of measurement uncertainty from the test equipment and methods. The product was tested as indicated below with results in conformance to the relevant test criteria. The following tests were performed: Test Description Leakage Current Test Power Input Test Temperature (normal) Test Dielectric Strength Tests on insulating materials Strain Relief Test Push-back Relief Conduit Connections(Ploymeric Enclosures): Pullout Conduit Connections(Ploymeric Enclosures): Torque Conduit Connections(Ploymeric Enclosures): Bending Secrement of Components Capacitor Discharge(Energy and Shock Hazards) Bonding Continuity Overload of Switches and Controls Static load test Abormal test: Output short circuit test Abormal test: Relay and solenoid burnout Abormal test: Transformer overload test Abormal test: Component short- and open-circuit test Flanged Bobbin Transformer Abnormal Test Capacitor Test Abnormal Operation Resistance to Impact Mold-Stress Relief Distortion Stain-Relief Test after Mold-Stress Relief Distortion UL 1012 Eighth Edition Dated November 9, 2010 containing Revisions through and including May 14, 2014 CSA C22.2 No Dated September 2001, Reaffirmed 2011 UL 746C Sixth Edition Dated September 10, 2004 containing Revisions through and including October 16, Signatures A representative sample of the product covered by this report has been evaluated and found to comply with the applicable requirements of the standards indicated in Section 1.0. Completed by: Eric Shao Reviewed by: Will Wang Title: Engineer Title: Supervisor Signature: Signature:

20 Page 20 of Correlation Page For Multiple Listings The following products, which are identical to those identified in this report except for model number and Listee name, are authorized to bear the ETL label under provisions of the Intertek Multiple Listing Program. BASIC LISTEE Address Country Product 5F., No.8, Alley 11, Lane 327, Sec. 2, Chung San Road, Chung Ho, Taipei County Taiwan Switching Power Supply MULTIPLE LISTEE 1 Address Country Brand Name ASSOCIATED MANUFACTURER Address Country None MULTIPLE LISTEE 1 MODELS BASIC LISTEE MODELS MULTIPLE LISTEE 2 Address Country Brand Name ASSOCIATED MANUFACTURER Address Country None MULTIPLE LISTEE 2 MODELS BASIC LISTEE MODELS MULTIPLE LISTEE 3 Address Country Brand Name ASSOCIATED MANUFACTURER Address Country None MULTIPLE LISTEE 3 MODELS BASIC LISTEE MODELS

21 Page 21 of General Information The Applicant and Manufacturer have agreed to produce, test and label ETL Listed products in accordance with the requirements of this Report. The Manufacturer has also agreed to notify Intertek and to request authorization prior to using alternate parts, components or materials. COMPONENTS Components used shall be those itemized in this Intertek report covering the product, including any amendments and/or revisions. LISTING MARK The ETL Listing mark applied to the products shall either be separable in form, such as labels purchased from Intertek, or on a product nameplate or other media only as specifically authorized by Intertek. Use of the mark is subject to the control of Intertek. The mark must include the following four items: 1) applicable country identifiers "US" and/or "C" or "US", "C" and "EU" 2) the word "Listed" or "Classified" or "Recognized Component" (whichever is appropriate) 3) a control number issue by Intertek 4) a product descriptor that identifies the standards used for certification. Example: For US standards, the words, Conforms to shall appear with the standard number along with the word, Standard or Std. Example: Conforms to ANSI/UL Std. XX. For Canadian standards, the words Certified to CAN/CSA Standard CXX No. XX. shall be used, or abbreviated, Cert. to CAN/CSA Std. CXX No. XX. Can be used together when both standards are used. Note: A facsimile must be submitted to Intertek, Attn: Follow-up Services for approval prior to use. The facsimile need not have a control number. A control number will be issued after signed Certification Agreements have been received by the Follow-up Services office, approval of the facsimile of your proposed Listing Mark, satisfactory completion of the Listing Report, and scheduling of a factory assessment in your facility. MANUFACTURING AND PRODUCTION TESTS Manufacturing and Production Tests shall be performed as required in this Report. FOLLOW-UP SERVICE Periodic unannounced audits of the manufacturing facility (and any locations authorized to apply the mark) shall be scheduled by Intertek. An audit report shall be issued after each visit. Special attention will be given to the following: 1. Conformance of the manufactured product to the descriptions in this Report. 2. Conformance of the use of the ETL mark with the requirements of this Report and the Certification Agreement. 3. Manufacturing changes. 4. Performance of specified Manufacturing and Production Tests. In the event that the Intertek representative identifies non-conformance(s) to any provision of this Report, the Applicant shall take one or more of the following actions: 1. Correct the non-conformance. 2. Remove the ETL Mark from non-conforming product. 3. Contact the issuing product safety evaluation center for instructions.

22 Page 22 of Evaluation of Unlisted Components Because Unlisted Components are uncontrolled, and they do not fall under a third party follow up program, Intertek may require these components to be tested and/or evaluated at least once annually, more often for certain components, as part of the independent certification process. The Unlisted Components in Section 5.0 require testing and/or evaluation as indicated. Note to Intertek Follow Up Inspector: The Component Evaluation Center, CEC, will notify you in writing when these components must be selected and sent to the CEC for re-evaluation Ship the samples to: Intertek Testing Services Shanghai Limited ETL Component Evaluation Center Building No. 86, 1198 Qinzhou Road (North) Shanghai , China Attn: Ms. Dansy Xu Sample Disposition: Due to the destructive nature of the testing, all samples will be discarded at the conclusion of testing unless, the manufacturer specifically requests the return of the samples. The request for return must accompany the initial component shipment.

23 Page 23 of Manufacturing and Production Tests The manufacturer agrees to conduct the following Manufacturing and Production Tests as specified: Required Tests Dielectric Voltage Withstand Test Grounding Continuity Test 11.1 Dielectric Voltage Withstand Test Method One hundred percent of production of the products covered by this Report shall be subjected to a routine production line dielectric withstand test. The test shall be conducted on products, which are fully assembled. Prior to applying the test potential, all switches, contactors, relays, etc., should be closed so that all primary circuits are energized by the test potential. If all primary circuits cannot be tested at one time, then separate applications of the test potential shall be made. The test voltage specified below shall be applied between primary circuits and accessible dead-metal parts. The test voltage may be gradually increased to the specified value but must be maintained at the specified value for one second or one minute as required. Test Equipment The test equipment shall incorporate a transformer with an essentially sinusoidal output, a means to indicate the applied test potential, and an audible and/or visual indicator of dielectric breakdown. The test equipment shall incorporate a voltmeter in the output circuit to indicate directly the applied test potential if the rated output of the test equipment is less than 500VA. If the rated output of the test equipment is 500VA or more, the applied test potential may be indicated by either: 1 - a voltmeter in the primary circuit; 2 - a selector switch marked to indicate the test potential; or 3 - a marking in a readily visible location to indicate the test potential for test equipment having a single test potential output. In cases 2 and 3, the test equipment shall include a lamp or other visual means to indicate that the test potential is present at the test equipment output. All test equipment shall be maintained in current calibration. Products Requiring Dielectric Voltage Withstand Test: Product Test Voltage Test Time All products covered by this Report. 1000V 60 s or 1200V 1 s

24 Page 24 of Grounding Continuity Test Method Each unit that has a power supply cord having a grounding conductor shall be tested for continuity between the grounding blade of the attachment plug and the inaccessible dead metal parts of the appliance that are required to be grounded. This may require testing before final assembly of the enclosure. Any indicating device (an ohmmeter, a battery-and-buzzer combination, or the like) may be used to determine compliance with the grounding continuity. Products Requiring Dielectric Voltage Withstand Test: Product All products covered by this Report.

25 Page 25 of Revision Summary The following changes are in compliance with the declaration of Section 8.1: Date/ Project Handler/ Proj # Site ID Reviewer Section Item Description of Change None

Listing Constructional Data Report (CDR)

Listing Constructional Data Report (CDR) Listing Constructional Data Report (CDR) 1.0 Reference and Address Report Number HZ12070036-0 Original Portable Electric Luminaires ANSI/UL 153(12th Ed, rev. March 24, 21) Standard(s) Portable Luminaires

More information

Listing Constructional Data Report (CDR)

Listing Constructional Data Report (CDR) Listing Constructional Data Report (CDR) 1.0 Reference and Address Report Number 3145135CRT-002 Original Standard(s) UL Standard for Safety for Inverters, Converters, Controllers and Interconnection System

More information

CLASSIFICATION Constructional Data Report (CDR)

CLASSIFICATION Constructional Data Report (CDR) CLASSIFICATION Constructional Data Report (CDR) 1.0 Reference and Address Report Number 100358381SAT-001 Original Standard(s) Fire Test for Heat and Visible Smoke Release for Discrete Products and Their

More information

Xiamen Comfort Science & Technology Group Co., Ltd 18 Long Shan South Road, Xiamen, Fujian Province, , China

Xiamen Comfort Science & Technology Group Co., Ltd 18 Long Shan South Road, Xiamen, Fujian Province, , China Applicant : Xiamen Comfort Science & Technology Group Co., Ltd 18 Long Shan South Road, Xiamen, Fujian Province, 361009, China Attn. to: Ms. Shen Manufacturing location : Zhangzhou Easepal Industrial Co.,

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2016-01-26 Page 1 of 7 Report Reference # E182560-V4-S52 UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES60601-1 (2005/(R)2012 + A1:2012, C1:2009/(R)2012 + A2:2010/(R)2012) - Amendment 1

More information

File E Project 08ME October 7, 2008 REPORT. UNLISTED COMPONENT - Attachment Plugs, Fuseless. For Use Only In

File E Project 08ME October 7, 2008 REPORT. UNLISTED COMPONENT - Attachment Plugs, Fuseless. For Use Only In File E170507 Project 08ME09223 October 7, 2008 REPORT ON UNLISTED COMPONENT - Attachment Plugs, Fuseless For Use Only In APPLICANT'S CLASSIFIED, LISTED OR RECOGNIZED PRODUCTS, SYSTEMS OR COMPONENTS Globtek

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2016-01-22 Page 1 of 9 Report Reference # E182560-V4-S48 UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES60601-1 (2005/(R)2012 + A1:2012, C1:2009/(R)2012 + A2:2010/(R)2012) - Amendment 1

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-12-01 Page 1 of 16 Report Reference # E252373-A31-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2014-10-14 (Information

More information

HISTORICAL OF SAMPLE RECEIVED EXAMINED SECTIONS

HISTORICAL OF SAMPLE RECEIVED EXAMINED SECTIONS HISTORICAL OF SAMPLE RECEIVED BVLCIE CHINA RECORDED N DETAIL OF THE SAMPLE SPECIAL REMARKS SZ130513/006 Original sample None SZ130328/002 Original sample None SZ130328/001 Original sample None EAMINED

More information

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance Page 1 of 165 Report No.: E309264-D1028-1/A0/C0-UL Test Report issued under the responsibility of: IEC 60601-1 Medical electrical equipment Part 1: General requirements for basic safety and essential performance

More information

SECTION (16460) - LOW-VOLTAGE TRANSFORMERS

SECTION (16460) - LOW-VOLTAGE TRANSFORMERS PART 1 GENERAL 1.01 SUMMARY SECTION 26 22 00 (16460) - LOW-VOLTAGE TRANSFORMERS A. Section Includes: 1. Dry-Type Distribution And Specialty Transformers Rated 1000 V And Less. a. General-Purpose Distribution

More information

Field Certification Certificate of Compliance

Field Certification Certificate of Compliance 2 Field Certification Certificate of Compliance Certificate: 2415870 Master Contract: 225996 Project: 2415870 Issued to: SpectraSensors, Inc. 11027 Arrow Route Rancho Cucamonga, CA 91730 USA Attention:

More information

Listing Constructional Data Report (CDR)

Listing Constructional Data Report (CDR) Listing Constructional Data Report (CDR) 1.0 Reference and Address Report Number 160800341SHA-002 Original Information Technology Equipment Safety Part 1: General Requirements (UL 60950-1 Issued: 2007/03/27

More information

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance Page 1 of 157 Report No.: E309264-D1009-1-CB CB - IEC REPORT: Test Report issued under the responsibility of: IEC 60601-1 Medical electrical equipment Part 1: General requirements for basic safety and

More information

SPECIFICATION FOR APPROVAL

SPECIFICATION FOR APPROVAL SPECIFICATION FOR APPROVAL CUSTOMER: JAMES PART NO: MODEL NO: DESIGNED NO: EDU120150 A2221 RoHS REVISION: 1-0 CATEGORY: AC ADAPTOR DATE SUBMITTED: 2016.03.15 SAMPLE/SPECIFICATION SUBMITTED SAMPLE 0 SPECIFICATION

More information

CERTIFICATION BULLETIN

CERTIFICATION BULLETIN File: ULC Subject C100 ULC-G.5.2 CCF7 S500F/SC2 October 28, 2014 CERTIFICATION BULLETIN 2014-07 Second Edition ULC/ORD-C100-13 Smoke Control System Equipment To: Members of the ULC Advisory Committee Members

More information

SPECIFICATION FOR APPROVAL

SPECIFICATION FOR APPROVAL SPECIFICATION FOR APPROVAL CUSTOMER: JAMES PART NO: 1953612 MODEL NO: DESIGNED NO: DDU050100 M2270 RoHS REVISION: 1-2 CATEGORY: EI-48 REGULATED ADAPTOR DATE SUBMITTED: 2014.11.14 SAMPLE/SPECIFICATION SUBMITTED

More information

TEST REPORT IEC Safety of household and similar electrical appliances

TEST REPORT IEC Safety of household and similar electrical appliances Page 1 of 114 TEST REPORT IEC 60335-1 Safety of household and similar electrical appliances Report Number.... : LCS180502075AS Date of issue... : June 11, 2018 Total number of pages... : 114 Name of Testing

More information

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance Page 1 of 170 Report No.: E309264-D1021-1/A1/C0-UL IEC REPORT: Test Report issued under the responsibility of: IEC 60601-1 Medical electrical equipment Part 1: General requirements for basic safety and

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES SECTION 26 36 23 AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SUNON SPECIFICATION FOR APPROVAL. ISSUE DATE Apple 12/28 REVISION DATE

SUNON SPECIFICATION FOR APPROVAL. ISSUE DATE Apple 12/28 REVISION DATE SPECIFICATION FOR APPROVAL CUSTOMER : Gicoda MOTOR TYPE : DESCRIPTION : MagLev Motor Fan DIMENSIONS : 60X60X25 mm M O D E L : KDE1206PTV3 P/N : MS.GN SUNON SPEC. NO. : D06034140G-00 APPROVAL NO. : APPROVED

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 20110304 Page 1 of 12 Report Reference # E302267A32UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: UL 606011, 1st Edition, 20060426 (Medical Electrical Equipment,

More information

Installation Instructions

Installation Instructions 50ES--A, 50EZ--A, 50VG--A, B, 50VL--A, B, 50VR--A, 50VT--A, B 604D-- --A, 607C-- --A, B, 607E-- --A, 704D-- --A, 707C-- --A, B, 707E-- --A PA3G -- -- A, PH3G -- -- A, PA4G, PH4G PAD3, PHD3, PAD4, PHD4,

More information

SECTION ISOLATED POWER SYSTEMS

SECTION ISOLATED POWER SYSTEMS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 20 11 ISOLATED POWER SYSTEMS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also, delete any other item or paragraph not applicable to

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY

More information

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 120X120X25 mm M O D E L : KD1212PTS1-6A

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 120X120X25 mm M O D E L : KD1212PTS1-6A SUNON SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : DC BRUSHLESS FAN DIMENSIONS : 120X120X25 mm M O D E L : KD1212PTS1-6A P/N : APPROVED NO : APPROVED BY : (AUTHORIZED) SPEC.NO D120015 DAWN. Hua

More information

Test Report. Appliance EMF Testing

Test Report. Appliance EMF Testing Project: 11014506A Date: November 6, 2015 Model: 120V_WWF13NW Test Report On Appliance EMF Testing Copyright 2005 UL LLC UL LLC authorizes the above-named company to reproduce this Report provided it is

More information

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate IECEx

More information

Installation and Operation Manual

Installation and Operation Manual Electronic Thermostats with Ground Fault Equipment Protection Model SST 2 40 Freeze Protection Thermostat P/N 22744 MANUAL We Manage Heat Model SST 2 175 Fixed Set Point Thermostat P/N 23708 Installation

More information

Remote Relay Module (RRM)

Remote Relay Module (RRM) Remote Relay Module (RRM) Instruction Manual WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like

More information

Low-voltage switchgear and controlgear - rated voltage does not exceed 1000V AC or 1500V DC

Low-voltage switchgear and controlgear - rated voltage does not exceed 1000V AC or 1500V DC CLASS PROGRAMME Type approval DNVGL-CP-0396 Edition December 2015 Low-voltage switchgear and controlgear - rated voltage does not exceed 1000V AC or 1500V DC The electronic pdf version of this document,

More information

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...

More information

DIGITAL CENTRALIZED Section NANOMASKIT

DIGITAL CENTRALIZED Section NANOMASKIT Page 1 of 8 1 GENERAL 1.1 RELATED SECTIONS 1.2 REFERENCES.1 Section 16010 Electrical General Requirements.2 Section 16120 Wire and Cable.3 Section 16993 Electrical Starting and Testing General Requirements

More information

File E90165 Vol. 2 Index Page 1 Issued: Revised: Construction United States Type Canadian Type Section

File E90165 Vol. 2 Index Page 1 Issued: Revised: Construction United States Type Canadian Type Section File E90165 Vol. 2 Index Page 1 Issued: 2001-05-02 Revised: 2008-07-21 INDEX Construction United States Type Canadian Type Section Jacketed Cords: Thermoplastic SVT, SVTO, SVTOO, SJT, SJTW SJTO, SJTOO,

More information

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements ExTR Reference Number...: ExTR Free Reference Number...: 223531 Compiled by + signature (ExTL)...: Reviewed by + signature (ExTL)...: NO/NEM/ExTR12.0018/00 Stig André Norheim Arne Hortman Date of issue...:

More information

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017 STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017 STANDARD INFORMATION Standard Number: UL 412 Standard Name: Refrigeration Unit Coolers Standard Edition and Issue Date: 5 th Edition Dated August 22,

More information

K-SQ13, KA-SQ13, K-SQ14, KA-SQ14, KO-SQ13, KOA-SQ13, KO-SQ14, KOA-SQ14, K-SQ13C, KA-SQ13C, K-SQ14C, KA- SQ14C, KO-SQ13C, KOA-SQ13C, KO-SQ14C,

K-SQ13, KA-SQ13, K-SQ14, KA-SQ14, KO-SQ13, KOA-SQ13, KO-SQ14, KOA-SQ14, K-SQ13C, KA-SQ13C, K-SQ14C, KA- SQ14C, KO-SQ13C, KOA-SQ13C, KO-SQ14C, age 2 of 14 Model/Type reference...: Ratings...: K-SQ13, KA-SQ13, K-SQ14, KA-SQ14, KO-SQ13, KOA-SQ13, KO-SQ14, KOA-SQ14, K-SQ13C, KA-SQ13C, K-SQ14C, KA- SQ14C, KO-SQ13C, KOA-SQ13C, KO-SQ14C, KOA-SQ14C,

More information

Installation Instructions

Installation Instructions 50ES---A, 50EZ---A, 50VL---A, 50VG---A, 50VR---A, 50VT---A, 604D--- ---A, 607C--- ---A, 607E,--- ---A, 704D--- ---A, 707C--- ---A, 707E--- ---A PA3G --- --- A, PH3G --- --- A SMALL PACKAGED PRODUCTS Electric

More information

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM TABLE OF CONTENTS Warnings............................................................................... 2 Package Contents........................................................................

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2613175 Master Contract: 162874 Project: 2613175 Date Issued: April 18, 2013 Issued to: Fujitsu Technology Solutions GmbH Product Compliance Center Buergermeister-Ulrich-Str

More information

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2011-01-24 Page 1 of 18 Report Reference # E183863-A17-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 2, 2018

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 2, 2018 STANDARDS UPDATE NOTICE (SUN) ISSUED: March 2, 2018 STANDARD INFORMATION Standard Number: UL 1206 Standard Name: Standard for Electric Commercial Clothes-Washing Equipment Standard Edition and Issue Date:

More information

Installation Requirements for Models:

Installation Requirements for Models: 900 & 9100 Series Refrigerators Installation Requirements for Models: 9162 9163 9182 9183 962 963 982 983 WARNING Improper installation, adjustment, alteration, service, or maintenance can cause injury

More information

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector PRODUCT SPECIFICATION 108-115057 29OCT13 Rev. A1 0.5mm Fine Stacking Hermaphroditic Type BTB Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for 0.5mm

More information

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL SECTION 16400 AUTOMATIC TRANSFER SWITCHES 1.01 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and general provisions of Contract, including General Conditions and Division 1 Specification sections, apply

More information

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax AllStyle Coil Company, LP 7037 Brittmore Houston, TX 77041 Phone 713-466-6333 Fax 713-466-6363 April 2005 VL / VLX Series Air Handler VL / VLX Series Air Handlers Installation Operation Maintenance The

More information

CONTENTS AUTOMATIC TRANSFER SWITCHES

CONTENTS AUTOMATIC TRANSFER SWITCHES CONTENTS AUTOMATIC TRANSFER SWITCHES PART 1 GENERAL 1.1 Related Documents 1.2 Summary 1.3 References 1.4 Quality Assurance 1.5 Submittals 1.6 Delivery, Storage and Handling 1.7 Instructions And Training

More information

Descriptive Report and Test Results

Descriptive Report and Test Results Descriptive Report and Test Results MASTER CONTRACT: 211066 Edition 1: Edition 2: November 4, 2013; Project 2661531 Montréal Issued by Viorel Popovici Eng., Review by: Gabriel Raymond B. En. January 20,

More information

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS... TITLE SPECIFICATION FOR PHOTOELECTRIC CONTROL UNITS (PECUs) REFERENCE REV DATE: JUNE 2017 PAGE: 1 OF 16 REVISION DATE: Table of Contents FOREWORD... 3 INTRODUCTION... 4 1 SCOPE... 4 2 NORMATIVE REFERENCES...

More information

TEMPORARY SPECIFICATION FOR REFERENCE

TEMPORARY SPECIFICATION FOR REFERENCE TEMPORARY SPECIFICATION FOR REFERENCE Customer : Description : EST FAN (Energy Saving Technology Fan) Customer Part No. REV. : Delta Model No. AFL12AUHE-00 REV. : 02 Sample Issue No. : Sample Issue Date

More information

Certification Supplement Manual

Certification Supplement Manual SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 5 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EU DECLARATION OF CONFORMITY 3 EUROPEAN

More information

Public Safety DAS Annunciator Panel

Public Safety DAS Annunciator Panel Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between //--// if not applicable to project. Also, delete any other item or paragraph

More information

SECTION INTERIOR LIGHTING

SECTION INTERIOR LIGHTING SECTION 26 51 00 INTERIOR LIGHTING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Oxygen (O2) Single-Point Gas Detection System

Oxygen (O2) Single-Point Gas Detection System Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity

More information

Model Number Structure

Model Number Structure Element Burnout Detector Accurate Detection of Element Burnout Regardless of Capacities Accurately detects a burned heater element or elements incorporated by a molding machine or packing machine and outputs

More information

Qualification Test Report 1/Jul/2005 Rev. A

Qualification Test Report 1/Jul/2005 Rev. A Qualification Test 501-93013 Report 1/Jul/2005 Rev. A AMP CO 10 Gigabit/s Insert PN 1711188-X 1. INTRODUCTION 1.1 Purpose Testing was performed on AMP* CO 10 Gigabit/s Insert, to determine its conformance

More information

Survey of electrical equipment installed in hazardous areas on tankers

Survey of electrical equipment installed in hazardous areas on tankers (June 2015) Survey of electrical equipment installed in hazardous areas on tankers 1. Application The recommendations in this document apply for survey of electrical installation in hazardous areas on

More information

The extent of liability of the signatory/signatories is limited to the work described above as the subject of this certificate.

The extent of liability of the signatory/signatories is limited to the work described above as the subject of this certificate. This safety certificate is an important and valuable document which should be retained for future reference DETAILS OF THE CLIENT Client / DETAILS OF THE INSTALLATION Extent of the installation covered

More information

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

Circuit Breakers JANUARY The electronic pdf version of this document found through   is the officially binding version STANDARD FOR CERTIFICATION No. 2.9 Approval Programmes Type Approval Programmes for EU recognised organisation Mutual Recognition (MR) No. MR-E001 Circuit Breakers JANUARY 2013 The electronic pdf version

More information

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual ITC 2000 HEATING CONTROL CABINET Installation & Operation Manual VTI, Incorporated 24 McMillan Way Newark, DE 19713 Phone (302) 738 0500 FAX (302) 738 6594 Revision Level 0.03 Manual No. 90003314 June,

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 This section specifies the furnishing, complete installation, and connection of automatic transfer switches. 1.2 RELATED WORK A. Section 14 21 00, ELECTRIC

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018 SECTION 26 2913 - ENCLOSED CONTROLLERS GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Installation Instructions

Installation Instructions EHNA Electric Heaters 5-20kW For 60 Hz Small Packaged Products MODELS: PAD3, PHD3, PAD4, PHD4, PAD5, PHD5, WPA3, WPH3 Installation Instructions NOTE: Read the entire instruction manual before starting

More information

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 2, 2018

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 2, 2018 STANDARDS UPDATE NOTICE (SUN) ISSUED: March 2, 2018 STANDARD INFORMATION Standard Number: UL 1082 Standard Name: Standard for Household Electronic Coffee Makers and Brewing-Type Appliances Standard Edition

More information

CII FCAC-150 Series Relay

CII FCAC-150 Series Relay Introducing CII Series Relay 50 Amps, 1PST/NO (DM) CII Series Relay 50 Amps, 1PST/NO (DM) with 1PDT Auxiliary Contacts KEY FEATURES Non-latching relay Balanced force design Corrosion protected metal enclosure

More information

Standards Update Notice (SUN) Issued: February 2, 2017

Standards Update Notice (SUN) Issued: February 2, 2017 Standard Information Standard Number: UL 778 Standard Name: Motor-Operated Water Pumps Standard Edition and Issue Date: 6 th Edition Issued July 7, 2016 and revision November 14, 2016 Date of Previous

More information

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External

More information

File S789 Project 04ME December 20, 2005 REPORT CONTROL UNIT (UOJZ) * * * * * * * * * * * * * * * * * * * * *

File S789 Project 04ME December 20, 2005 REPORT CONTROL UNIT (UOJZ) * * * * * * * * * * * * * * * * * * * * * File S789 Project 04ME15779 December 20, 2005 REPORT on CONTROL UNIT (UOJZ) * * * * * * * * * * * * * * * * * * * * * Complementary Product Categories CENTRAL STATION ALARM UNITS (AMCX, AMCX7) POLICE STATION

More information

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear IEC/PAS 62271-109 Edition 1.0 2002-07 High-voltage switchgear and controlgear Part 109: Alternating-current series capacitor by-pass switches PUBLICLY AVAILABLE SPECIFICATION INTERNATIONAL ELECTROTECHNICAL

More information

APPROVAL REPORT. J.l. 3ZOA9.AX

APPROVAL REPORT. J.l. 3ZOA9.AX NOT to be distributed outside the FACTORY MUTUAL SYSTEM, except by CLIENT. APPROVAL REPORT MODEL FA-249-HA and FA-250-HA MARINE SIGNAL LANTERN USING MODEL APCL-5 FLASHCHANGER Part Numbers 8087-0122, 8087-0123,

More information

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date: Energy Report EDR-5391 Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49 Qualification Testing of Nuclear High Voltage Splice (NHVS) Enclosures: Report Number: Date: EDR-5391

More information

CR Series Command Relays

CR Series Command Relays CR Series Command Relays FEATURES INSTALLATION INSTRUCTIONS Patented 35mm Din-rail mounting flange (US Patent 7,416,421) SPDT Form 1C Relay contacts Pilot duty rated LED status indication Stackable for

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

AC/DC Power Supply and Battery Charger Installation and Maintenance

AC/DC Power Supply and Battery Charger Installation and Maintenance AC/DC Power Supply and Battery Charger Installation and Maintenance 61175043L3-5A Issue 1, January 2004 CLEI Code: SIMPAADA_ CLEI Code: SIMPAAGA_ CONTENTS 1. GENERAL... 1 2. DESCRIPTION... 1 3. INSTALLATION...

More information

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM TABLE OF CONTENTS Warnings...2 Package Contents...2 General Information...3 Ceiling Plenum Installation Requirement...3 Supply Ducting

More information

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems Qualification Test Report 501-93032 14/April/2011 Rev A AMP-TWIST Series Jacks for Class EA systems 1. INTRODUCTION 1.1 Purpose Qualification testing on AMP-TWIST* Series Jacks for Class E A Systems, to

More information

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM SECTION 40 71 66 ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM PART 1-GENERAL 1.01 SUMMARY A. Ultrasonic clamp-on flow measurement system designed for non-intrusive external to pipe measurement

More information

Installation Instructions

Installation Instructions 50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions

More information

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330A755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)

More information

Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services

Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services www.intertek.com/lighting 1 Identifying Product Safety Requirements for Your Target Markets

More information

Schneider Electric Erie T155 Series

Schneider Electric Erie T155 Series Schneider Electric Erie T Series Non-Digital, On/Off Thermostat General Instructions Application The T series thermostat provides on/off control for low voltage and line voltage valves, relays and fan

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following

More information

Refrigerating Appliance DOE Test Report

Refrigerating Appliance DOE Test Report Report Number Test Laboratory Name / Address Applicant Name / Address Manufacturing Name / Address Product Brand Name Description Model(s) (if applicable) Model Similarity Ratings Refrigerating Appliance

More information

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance 5 List of

More information

Dual Column Dehydrating Breather Manual

Dual Column Dehydrating Breather Manual Dual Column Dehydrating Breather Manual DCB-MANUAL 1.6 Read and understand this manual prior to operating or servicing the products. SPX Transformer Solutions, Inc., Service & Components Division U.S.

More information

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER JOCKEY PUMP CONTROLLER Model JPCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page 4 Model

More information

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS OF COLEMAN -MACH AIR CONDITIONERS TABLE OF CONTENTS

More information

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION: RELEASE DEVICES MADE IN THE U.S.A. RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: The "WPS" World Power Series, Time Delay Release

More information

Honeywell Durafit LED Retrofit Kit

Honeywell Durafit LED Retrofit Kit Honeywell Durafit LED Retrofit Kit INSTALLATION INSTRUCTIONS LED RETROFIT LUMINAIRE CONVERSION FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS

More information

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase General Specification 550 VA/Watts 1300 VA/Watts 1.0 GENERAL This specification defines the electrical and mechanical characteristics

More information

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117 Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel Revision E 61117 CAUTION: (Read This First) This panel has been designed to make it nearly bullet proof to mistakes made when wiring

More information

Test Report Garvan Enterprises Limited

Test Report Garvan Enterprises Limited Test Report 8526255. Garvan Enterprises Limited Page 1 of 14 Introduction. This report has been prepared by A Reeve and relates to the activity detailed below: Job/Registration Details Job number: 8526255

More information

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS SEEKIRK, INC. 2420 Scioto Harper Dr. Columbus, OH 43204 Tel: (614) 278-9200 FAX: (614) 278-9257 email: seekirk@seekirk.com

More information

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS

More information

SUNON SPECIFICATION FOR APPROVAL : SUNON INC : SPEC.NO D G-00 ISSUE DATE Dolphin 7/19 REVISION DATE

SUNON SPECIFICATION FOR APPROVAL : SUNON INC : SPEC.NO D G-00 ISSUE DATE Dolphin 7/19 REVISION DATE SPECIFICATION FOR APPROVAL CUSTOMER MOTOR TYPE DESCRIPTION DIMENSIONS M O D E L P/N SUNON SPEC. NO. CUSTOMER APPROVAL NO. APPROVED BY CUSTOMER (AUTHORIZED) : SUNON INC : : MagLev Motor Fan : 40X40X10 mm

More information