MICROPOINT to MICROPOINT II UPGRADE
|
|
- Dustin Ferguson
- 6 years ago
- Views:
Transcription
1 MICROPOINT to MICROPOINT II UPGRADE Why is INTREPID II an intelligent upgrade choice for my customer?. II is highly scalable and can be easily configured to address a range of security requirements, site characteristics and system sizes. 2. The common communications protocol of our INTREPID Series II detection suite enables single-platform networking of II with other Series II systems (MicroTrack II, MicroWave 330), enabling integration flexibility when layering of technologies is required. 3. Common DC Power ( VDC) is specified for all Series II devices, incl. II. 4. For simplified sensor configuration, user-friendly Universal Installation Service Tool II (UIST II) software manages set-up of all INTREPID Series II systems, including II. 5. Flexible controller options address all budgets and project needs, from local or remote relay control to centralized GUI-based solutions for TCP/IP management of large or multi-site applications. 6. Two developer-friendly SDK options simplify integration of II (and all INTREPID Series II devices) to third party IM, VMS or custom control applications. 7. Industry-leading 5-year Warranty protection on all II equipment. What elements remain the same between and II systems?. The sensor cable is identical for both systems. As long as cable from an original system has been well-maintained, it may be reused with II hardware. 2. Module locations are identical for both systems. Upgrade is as simple as a change of hardware. 3. Detection zones are assigned in system software for flexibility and cost savings. 4. Zone integration with CCTV presets offers precise visual assessment of alarms. 5. Sensitivity Leveling software-based calibration achieves uniform detection sensitivity. 6. Point Impact Discrimination provides reliable detection and nuisance alarm rejection. 7. Both systems offer precise location of alarms to within 3 m / 0 ft. 8. Integration with Southwest Microwave s legacy sensors and third party devices. How long can I continue to purchase original INTREPID equipment? Original systems have reached End of Life. Though we plan to support product repairs through 202, limited spare and replacement parts are available and many system components are already out of stock. CORPORATE HEADQUARTERS: SOUTHWEST MICROWAVE, INC S. MCKEMY ST. TEMPE, ARIZONA USA TEL INFOSSD@SOUTHWESTMICROWAVE.COM EUROPEAN OFFICES: SOUTHWEST MICROWAVE LTD. #3, DEER PARK BUSINESS CTR WOOLLAS HILL, ECKINGTON, WORCESTERSHIRE WR0 3DN UK TEL /8
2 FENCE DETECTION SYSTEMS GENERAL FEATURES SERIES I SERIES II II Warranty Terms Yr (std), Yr + 2 Yr Ext. Warranty (on registration) 3 Yr (std), 3 Yr + 2 Yr Ext. Warranty (on registration) Communications Protocol Unique to Universal Alarm Location / Resolution 3 m / 0 ft 3 m / 0 ft Sensitivity Leveling calibration feature achieves uniform detection sensitivity across the protected fence line Point Impact Discrimination detects legitimate intrusion attempts but rejects environmental nuisance alarms Detection Length Per 209 m 220 m Network Architecture Communication Ports Remote Sensor Administration Direct Connection: RS-232 or RS-422 Network Interface Module RS-422 Adapter Card RS-232 Adapter Card Star, Loop, Fault Tolerant Loop 2 built-in RS-422 (Comm) RS-232 (Set-up) With CM II-N, GCM II-HD Controllers Power Conversion With Power Converter Card Built-in Installation / Service Software Voltage range Alarm Response Time Software-based integration to third-party security or video management systems (IM / VMS) Integration with CCTV for precise assessment of alarms System Size Parameters (Max Number of Devices on a Single Communications Bus) Dedicated service tool for each sensor Varies by device type Variable (< sec per system) Dedicated SDK: TPI - Cable SDK - MicroTrack, M, TPI 8 PMs / system M: 64 systems / PC TPI: Universal Installation / Service Tool (UIST II) Universal (0.5-60VDC) Predictable 25 ms / device (up to 8 devices) Common SDK: IPP II: HLI RPM II: HLI +, M, SDK, ASCII (GCM II-HD) RCM II: 8 devices CM II-N: 6 devices (4 remote) GCM II-HD: 32 devices M: 240 devices IPP II SDK: RPM II SDK: 6 CORPORATE HEADQUARTERS: SOUTHWEST MICROWAVE, INC S. MCKEMY ST. TEMPE, ARIZONA USA TEL INFOSSD@SOUTHWESTMICROWAVE.COM 2 EUROPEAN OFFICES: SOUTHWEST MICROWAVE LTD. #3, DEER PARK BUSINESS CTR WOOLLAS HILL, ECKINGTON, WORCESTERSHIRE WR0 3DN UK TEL /8
3 SYSTEM CONTROLLERS Relay Module This control module offers smaller facilities with cost-effective local control of INTREPID, contact-closure auxiliary security devices and CCTV equipment or other security inputs. 8 on board relays. Basic Map Monitor / Advanced Map Monitor / Multi-Map Monitor Windows-based monitoring software for system. On-screen GUI with display of alarms to within 3 m. Basic alarm reports. Five language capability. Alarm Tagging. Single or multi-site use. Single or multiple PC use. 70 zones maximum. Requires user PC. Consult data sheet for minimum technical requirements. Relay Control Module II Offers smaller facilities with cost-effective local control of INTREPID Series II devices, contact-closure auxiliary security devices and CCTV equipment or other security inputs. Simple zone record setup via terminal emulator. 8 on board relays. Connects up to 8 devices. Control Module II-N Relay-based system control module designed to offer facilities with local or remote control of INTREPID Series II devices, contact closure auxiliary security devices and CCTV equipment or other inputs. Features zone assignment and management via Controller Setup Tool II (CST II) terminal emulator. Supports multiple languages and auto-discovery of all connected devices. Connects up to 6 local devices (or 4 remote). 256 zone records. Graphic Control Module II-HD Dedicated, Linux-based system controller, offering local GUI-based alarm monitoring and control of INTREPID Series II devices and contact-closure auxiliary security devices, CCTV equipment or other security inputs. Supports multiple languages, auto-discovery of all connected devices. 256 user accounts, connects up to 32 devices, 024 zone records. ASCII output for serial CCTV interface. Hardened or standard versions available. Perimeter Security Manager Advanced, Windows-based security monitoring and control system for large or multi-site facilities. Local or remote GUI-based alarm monitoring and control of INTREPID devices and contact-closure auxiliary security devices. High level interface to CCTV, incorporating live video and maps on a single display. Installable on user PC. Requires user PC. Consult data sheet for minimum technical requirements. Third Party Interface (TPI) Windows-based DLL available free of charge to developers for high-level integration of system into custom control applications. Software Development Kits (SDK) Available free of charge to developers for high-level integration of MicroPOint II and other INTREPID Series II devices into custom control applications. Platform-independent. II Two developerfriendly SDK options (IPP II / RPM II) CORPORATE HEADQUARTERS: SOUTHWEST MICROWAVE, INC S. MCKEMY ST. TEMPE, ARIZONA USA TEL INFOSSD@SOUTHWESTMICROWAVE.COM 3 EUROPEAN OFFICES: SOUTHWEST MICROWAVE LTD. #3, DEER PARK BUSINESS CTR WOOLLAS HILL, ECKINGTON, WORCESTERSHIRE WR0 3DN UK TEL /8
4 Southwest Microwave, Inc. Telephone + (0) to II Upgrade Alarm Annunciation Matrix SCALE NTS DRAWN TG DATE 2/7/207 Alarm Annunciation Chart METHOD Controller INTREPID Controller INTREPID II Outputs Zones Outputs Zones RELAY 70* RCM II CM II-N GUI Basic Monitor Multi-Map Monitor Advanced Monitor M CCTV Driver 70* GCM II-HD M ASCII for CCTV CCTV Driver 024 THIRD PARTY TPI 70* RPM II SDK ** IPP II SDK 28** * 70 Zones (50 Display Segments, 20 Auxiliary Sensors) ** RPM II provides internal 28 Zone Records for backup alarm annunciation via local form-c dry relay outputs.
5 Telephone + (0) Southwest Microwave, Inc. 4 3 to II Upgrade SCALE NTS Alarm Annunciation Via Form-C Dry Relay Contacts Conceptual System Design DRAWN TG DATE PM II- LU II- 3 4 PM- LU- LU-4 LU-2 PM II-2 //207 ROM II CM II-N LU II-3 LU II-2 PM-2 PM II-4 PM-4 TU II &2 PM II-3 LU-3 PM-3 VDC PM- NIM 2VDC RS form-c outputs for alarm annunciation. 3 form-c outputs for alarm annunciation. Existing 2-wire RS5 communication replaced with 4-wire ROM II available in 8 & 6 outputs. ROM II6 CM II-N PM II- VDC 2VDC * = Zone break locations from the existing system will be replicated on the MicroNet II system. 2VDC Power & Alarm/ Built-In Remote System/ Sensor Diagnostics & Maintenance TCP/IP II System Communication & Power Wiring Typical Block Diagram 2VDC Power & Alarm/ 3 System Communication & Power Wiring Typical Block Diagram Existing 4-Processor System - Typical Upgraded 4-Processor II System - Typical
6 Telephone + (0) Southwest Microwave, Inc. 4 3 to II Upgrade SCALE NTS Alarm Annunciation Via Local Graphical User Interface Conceptual System Design DRAWN TG DATE PM II- LU II- 3 4 PM- LU- Map Monitor LU-4 LU-2 PM II-2 GCM II-HD ROM II LU II-3 LU II-2 PM-2 PM II-4 PM-4 TU II &2 PM II-3 LU-3 PM-3 VDC 422A PM- NIM -2 - RS5 Data Converter 2VDC system triggering. 3 //207 PM II- VDC system triggering. 3 Reuse existing 4-wire communication line. ROM II6 ROM II-8 2VDC * = Zone break locations from the existing system will be replicated on the MicroNet II system. GCM II-HD 2VDC Power & Alarm/ Built-In Remote System/ Sensor Diagnostics & Maintenance TCP/IP II System Communication & Power Wiring Typical Block Diagram 2VDC Power & Alarm/ Map Monitor GUI RS232 System Communication & Power Wiring Typical Block Diagram Existing 4-Processor System - Typical Upgraded 4-Processor II System - Typical
7 Telephone + (0) Southwest Microwave, Inc. 4 3 to II Upgrade SCALE NTS Alarm Annunciation Via Third Party High Level Interface Conceptual System Design DRAWN TG DATE PM II- LU II- 3 4 PM- LU- IM/VMS LU-4 LU-2 PM II-2 //207 ROM II RPM II LU II-3 LU II-2 PM-2 PM II-4 PM-4 TU II &2 PM II-3 LU-3 PM-3 VDC 422A PM- NIM -2 - RS5 Data Converter 2VDC system triggering. 3 Third Party IM/VMS system/failsafe alarm triggering. Reuse existing 4-wire communication line. ROM II available in 8 & 6 outputs. ROM II6 RPM II PM II- VDC 2VDC * = Zone break locations from the existing system will be replicated on the MicroNet II system. 2VDC Power & Alarm/ Built-In Remote System/Sensor Diagnostics & Maintenance 3 TCP/IP II System Communication & Power Wiring Typical Block Diagram 2VDC Power & Alarm/ Third Party IM/VMS RS232 System Communication & Power Wiring Typical Block Diagram Existing 4-Processor System - Typical Upgraded 4-Processor II System - Typical
PROVEN PERIMETER PROTECTION NEW SINGLE-PLATFORM SIMPLICITY.
SMARTER PERIMETER DETECTION SYSTEMS MicroPoint II Fence Detection System MicroTrack II Buried Cable Detection System MicroWave 330 Digital Microwave Link PROVEN PERIMETER PROTECTION NEW SINGLE-PLATFORM
More informationINTREPID Perimeter Intrusion Detection System
TM INTREPID Perimeter Intrusion Detection System Next Generation Perimeter Protection icropoint Cable combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience.
More informationProduct Specifications
Southwest Microwave, Inc. 9055 S. McKemy Street Tempe, Arizona 85284 USA +1(480) 783-0201 Fax +1(480) 783-0401 Product Specifications 1.0 INTREPID Series II - MicroNet II Perimeter Intrusion Detection
More informationINTREPID Buried Cable Perimeter Intrusion Detection System
TM INTREPID Buried Cable Perimeter Intrusion Detection System icrotrack, the latest addition to Southwest Microwave s INTREPID family of intrusion detection products, is a new buried cable intrusion detection
More informationINTREPID Buried Cable Perimeter Intrusion Detection System
INTREPID Buried Cable Perimeter Intrusion Detection System TM M icrotrack, the latest addition to Southwest Microwave s INTREPID TM family of intrusion detection products, is a new buried cable intrusion
More informationINTREPID SINGLE-PLATFORM PERIMETER INTRUSION DETECTION AND MONITORING SYSTEM
Southwest Microwave, Inc. 9055 S. McKemy Street Tempe, Arizona 85284 USA +1(480) 783-0201 Fax +1(480) 783-0401 Product Specifications INTREPID SINGLE-PLATFORM PERIMETER INTRUSION DETECTION AND MONITORING
More informationINTEGRATED PERIMETER SECURITY SOLUTIONS
INTEGRATED PERIMETER SECURITY SOLUTIONS FENCE DETECTION SYSTEMS BURIED CABLE DETECTION SYSTEMS MICROWAVE DETECTION SENSORS INFRARED AND DUAL TECHNOLOGY SENSORS ALARM MONITORING AND CONTROL SYSTEMS PROVEN
More informationINTEGRATED PERIMETER SECURITY SOLUTIONS FENCE DETECTION SYSTEMS BURIED CABLE DETECTION SYSTEMS ALARM MONITORING AND CONTROL SYSTEMS MICROWAVE SENSORS
FENCE DETECTION SYSTEMS BURIED CABLE DETECTION SYSTEMS ALARM MONITORING AND CONTROL SYSTEMS MICROWAVE SENSORS RELOCATABLE MICROWAVE SENSORS INFRARED AND DUAL TECHNOLOGY SENSORS INTEGRATED PERIMETER SECURITY
More informationProduct Specification
Southwest Microwave, Inc. 9055 S. McKemy Street Tempe, Arizona 85284 USA (480) 783-0201 Fax (480) 783-0401 Product Specification INTREPID MicroTrack Buried Cable Perimeter Intrusion Detection System System
More informationProduct Specifications
Southwest Microwave, Inc. 9055 S. McKemy Street Tempe, Arizona 85284 USA (480) 783-0201 Fax (480) 783-0401 Product Specifications Procurement Specifications INTREPID MicroPoint Cable System Perimeter Detection
More informationMilestone SMI Intrepid II Perimeter Module 1.1 User s Manual
Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual Target Audience for this Document This document is aimed at system users and provides descriptions on how to install and maintain the Milestone
More informationArchitectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone
Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System FlexZone April 15, 2014 Page 1 of 14 G6DA0115-001 This document is intended to provide performance specifications
More informationG-MAX IVS R123 Vibration Sensors Perimeter Intrusion Detection System
PS-4001-48461-A G-MAX IVS R123 Sensors Perimeter Intrusion Detection System Product Specifications G-Max Security Tech Ltd a l d o r e c o t e c L td. I n t e g r a t e d S e c u r i t y s y s t e m s
More informationSUPREMATouch. Modular Fire & Gas Detection System
SUPREMATouch Modular Fire & Gas Detection System Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel from hazardous gases in
More informationArchitectural and Engineering Specification for a Security Management System. StarNet 2
Architectural and Engineering Specification for a Security Management System StarNet 2 Jan 2, 2018 Page 1 of 12 AE-S2-IN-R1-EN-01/18 This document is intended to provide performance specifications and
More informationSUPREMATouch. Modular Fire & Gas Detection System
SUPREMATouch Modular Fire & Gas Detection System Tel: +44 (0)8 9388 Email: info@ Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel
More informationFour-Door Access Controller User s Manual
Four-Door Access Controller User s Manual V1.0.0 1 Table of Contents 1 Overview... 1 2 Device Appearance... 2 3 Device Installation... 4 4 System Cabling and Structure... 5 4.1 Cabling... 5 4.2 Structure...
More informationZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL
ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options
More informationArchitectural and Engineering Specification for a Hybrid Perimeter Intrusion Detection and Intelligent Lighting System.
Architectural and Engineering Specification for a Hybrid Perimeter Intrusion Detection and Intelligent Lighting System Senstar LM100 AE-E8-IN-R2-E-1118 Page 1 of 14 This document is intended to provide
More informationFiber Optic Cable Fence Disturbance Sensor
Architectural & Engineering Specification for Fiber Optic Cable Fence Disturbance Sensor Purpose of document This document is intended to provide performance specifications and operational requirements
More informationScanlight Next generation dimmable addressable lighting control
Scanlight Next generation dimmable addressable lighting control Road Tunnel and Underpass Systems Next generation dimmable addressable lighting control Scanlight is a next generation dimmable addressable
More informationArchitectural and Engineering Specification for a Fiber Optic Pipeline Integrity Monitoring System. FiberPatrol FP7000
Architectural and Engineering Specification for a FiberPatrol FP7000 SECTIONS 1. PIPELINE MONITORING SYSTEM TO DETECT LEAKS AND THIRD-PARTY INTERFERENCE... Page 3 2. PIPELINE MONITORING SYSTEM TO DETECT
More informationMicrophonic Cable Fence Disturbance Sensor (multiplex version)
Architectural & Engineering Specification for Microphonic Cable Fence Disturbance Sensor (multiplex version) Purpose of document This document is intended to provide performance specifications and operational
More informationAPPLICATION DATA SHEET
APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable
More informationFour-Door Access Controller User s Manual
Four-Door Access Controller User s Manual V1.0.0 1 Table of Contents 1 Overview... 1 2 Device Appearance... 2 3 Device Installation and Uninstallation... 3 3.1 Device Installation... 3 3.2 Device Uninstallation...
More informationIntelligent Single Loop Fire Alarm Control Panel
Intelligent Single Loop Fire Alarm Control Panel The CAX-CTL-1L Intelligent Single Loop Fire Alarm Control Panel is a member of the industry leading Axis AX Series Intelligent Fre Alarm Control Panels
More informationIntroducing the innovative ipids Indoor Outdoor Detection System MANUFACTURING SECURITY SOLUTIONS
Introducing the innovative ipids Indoor Outdoor Detection System 1 SENSITIVE Electronic Sensors installed on the perimeter fence, and communicating to a central computer. Can adapt to any type of fence.
More informationDesign. Innovations in Integrated Control Systems
Design Innovations in Integrated Control Systems Halvard Foss Kongsberg Maritime AS October 17-18, 2006 Return to Session Directory Innovations in Integrated Control Systems Halvard Foss Kongsberg Maritime
More informationFlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a
Architectural/Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System FlexPS Disclaimer Senstar, and the Senstar logo are registered trademarks, and FlexPS, Silver Network and
More informationRefrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA
Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA 99336 www.jmcvr.com 1-509-586-9893 Table of Contents TABLE OF FIGURES...1 OVERVIEW OF THE HRC CAPABILITIES...2 INSTALLATION AND
More informationAdvanced FireAlarm Panel 1-4Loop
Advanced FireAlarm Panel 1-4Loop Advanced Technologies Advanced Electronics Ltd IP Gateway Monitoring and interrogation via the internet Password protected multiple user permissions Event notification
More informationThe EN54 Part 2 & 4 Fire System
Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54
More information21-light Remote Annunciator. Owner s Manual
21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With
More informationSmartAlarm Annunciator
Annunciator Specification/Features The Annunciator offers a modern compact DIN package that includes state of the art critical alarm capture in an industry standard footprint 1. High Intensity LED s 2.
More informationZXSe Range Data Sheet
ZXSe Range Data Sheet Analogue addressable fire alarm control panel Product Overview The ZXSe range of analogue addressable fire alarm control panels have been designed and constructed around proven and
More informationSecurity designed for your lifestyle
Security designed for your lifestyle The Paradox Insight : The Big Picture A single CAT5 or higher cable can be used to wire a single HD77 camera. Camera Detector Module HD 720p camera Quad PIR with auto
More informationInstruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual
Instruction manual MTL process alarm equipment October 2016 CSM 725B rev 2 MTL RTK 725B Configuration Software Manual SECTION 1 - INTRODUCTION... 5 Basic Requirements... 5 SECTION 2 - SOFTWARE INSTALLATION...
More informationMetasys Integrator Cleaver-Brooks Application
Metasys Connectivity Technical Manual 69. Metasys Integrator Section Application Note Issue Date 0900 APPLICATION NOTE Metasys Integrator Cleaver-Brooks Application lntroduction Page Application Details
More informationZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features
Fire Safety ZXSe Range Analogue addressable fire alarm control panel The ZXSe range of analogue addressable fire alarm control panels have been designed and constructed around proven and reliable microprocessor
More informationCX/CXB Self-Managed Ethernet Switches N-664 Network Appliance Data and Alarm I/O Device MX Series Multi-Port Switches
integrate everything only afi delivers comprehensive security network infrastructure The network appliances typically deployed in security networks were most likely manufactured for general network connectivity
More informationThe IPPS was developed on IBM-PC platform under QNX real time operating system (RTOS) and uses QNX-Windows GUI.
IAEA-SM-367/4/02/P INTEGRATED PHYSICAL PROTECTION SYSTEM Ranajit Kumar Control Instrumentation Division, Bhabha Atomic Research Center, Trombay, Mumbai 400085, India Abstract An Integrated Physical Protection
More informationWG Buried Cable Perimeter Detection System
Telephone : +44 (01295 756300 Fax : +44 (0)1295 756302 E-Mail : info@wi-ltd.com Website : www.wi-ltd.com WG Buried Cable Perimeter Detection System The WG Cable Detection Sensor is a covert outdoor perimeter
More informationIntelligent 2 & 4 Loop Fire Alarm Control Panels
Intelligent 2 & 4 Loop Fire Alarm Control Panels Advanced has combined the latest technology with many years of fire experience, to create the Axis AX Series Intelligent Fire Alarm Control Panels. The
More informationFacility Explorer Asset Protection by Yorkland Controls Ltd. Fr
Date: October 13, 2006 Announcing: Facility Explorer Asset Protection by Yorkland Controls Ltd. Fr Facility Explorer Asset Protection Yorkland Controls Ltd. is excited to announce a significant addition
More informationControl System Structure
Control System Structure Centralized Controller Wireless Controller Centralized Controller Wired Controller BMS User Friendly Management Control Solution Integrated Management Building Management Convenient
More informationFrequently asked questions: Intelligent Transmitter Series
Frequently asked questions: Intelligent Transmitter Series The Wilcoxon family of Intelligent Transmitters, relay alarms, and communication modules can be used to implement low-cost online vibration monitoring
More informationSiteSentinel itouch Console
SITESENTINEL ITOUCH CONSOLE SiteSentinel itouch Console OPW s SiteSentinel itouch is a multifunction, high-quality tank-monitoring system that provides real-time, accurate inventory information for up
More informationMHC Series Sensors
MHC - 4000 Series Sensors Smart Sensors for Permanent Installation Shaft Speeds above 30 RPM & 0.25-60 RPM Sigma Sensors for Intermittant Operation Kittiwake Holroyd Ltd A Kittiwake Group Company The MHC
More information20 Light Remote Annunciator
Light Remote Annunciator Owner s Manual Surface Mount Flush Mount 94-95- Standard Annunciator 94-, 94-95-, 95-4- 4- Annunciator w/remote Relay Panel 4-, 4-4-, 4-49-, 49-49-, 49- Time Multiplexed Annunciator
More informationDATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D
DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.
More informationArchitectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1100X
Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System FiberPatrol FP1100X December 2017 Page 1 of 14 AE-FP-001-IN-R5-E-12/17 This document is intended to provide
More informationGallagher System Integrations
Gallagher System Integrations Gallagher Command Centre supports integrations with a range of third party security products, using Gallagher developed interface software and industry standard protocols.
More informationArchitectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1150
Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System FiberPatrol FP1150 April 2018 Page 1 of 14 AE-FP-005-IN-R1-E-04/18 This document is intended to provide
More informationIS IP Video Door Phone. FEATURES
IS-6500 www.asia.security.honeywell.com IP Video Door Phone Honeywell s IS-6500 is a stylish TCP/IP based Video Door Phone system delivering flexibility and control required for high-end property complex
More informationBuried ported coaxial cable outdoor intrusion detection system
Architectural & Engineering Specification for Buried ported coaxial cable outdoor intrusion detection system Purpose of document This document is intended to provide performance specifications and operational
More informationCCU Family of Modules
The CCUNet range of products, when integrated with XL, provide fire network amalgamation for various differing fire networks. Rapid and effective monitoring and control is provided via multi-drop secure
More informationDew point set DS 400
set DS 400 Dew point set DS 400 for stationary dew point monitoring of refrigeration or adsorption dryers. The touch screen graphic display enables an intuitive operation and shows the progress of the
More informationSection PERIMETER SECURITY SYSTEMS
Section 28 16 43 PERIMETER SECURITY SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Provide and install a perimeter security system as herein specified for the purpose of detecting entry into a designated security
More informationSIMATRIX NEO Modular Video Matrix
SIMATRIX NEO Modular Video Matrix SIMNEO-168 Modular Design Expandable up to 224 Video-Inputs, 32 Video-Outputs Up to 8 keyboards can be connected for control Multiple protocol driver for the direct control
More informationAm I safe working in this building?
Am I safe working in this building? Fusion is a user-friendly security management solution providing situational awareness and peace of mind at all times. Answers for infrastructure. Sophisticated technology
More informationDRAFT 20 October 2014
Technical data MTL process alarm equipment EPS rev 8 Programmable alarm annunciator Modular construction from 1 to 256 alarm channels Multi-redundant design so there is no single point of failure Choice
More informationIntelligent Addressable Fire Alarm System
Intelligent Addressable Fire Alarm System Company Profile The Company established in 2003, is manufacturing security system devices with the brand name DEKON Security Technologies for the exclusivity of
More informationA Smart & Integrated Security solution
Advisor Advanced A Smart & Integrated Security solution In a connected world Empowered with UltraSync services Security and Access Control in one providing a scalable system UTC s Advisor Advanced security
More informationArchitectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone
Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System FlexZone October 27, 2015 Page 1 of 15 AE-G6-IN-R4-E-10/15 This document is intended to provide performance
More informationCompressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture
meas. according to ISO 8573 Residual oil content - particles - moisture DS 500 - the intelligent chart recorder of the next generation. The centerpiece of compressed air quality measurement is the chart
More informationReliably Advanced Extinguishing Control
Reliably Advanced Extinguishing Control 14 years. 60 countries. Still Advanced. We re the same people, with the same commitment to excellence and customer satisfaction and now we have a brand that reflects
More informationWG Buried Fibre Cable Long Perimeter Detection System
WI CODE : 11954 Telephone : +44 (01295 756300 Fax : +44 (0)1295 756302 E-Mail : info@wi-ltd.com Website : www.wi-ltd.com WG Buried Fibre Cable Long Perimeter Detection System The WG Buried Cable Long Perimeter
More informationATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.
ATSTORM v2 ATSTORM v2 is a storm detector that measures the environmental electric field. It is fully automatic, without mobile parts, robust and highly reliable The storm detector ATSTORM v2 basic configuration
More informationOpenDevice United Technologies Corporation. Lenel is a part of UTC Climate, Controls & Security, a unit of United Technologies Corporation.
OpenDevice The OnGuard OAAP program allows third party manufacturers (OAAP partners) to interface their products with the OnGuard platform. OpenDevice is one of the API groups supported by OnGuard. OpenDevice
More informationTOTAL PERIMETER SOLUTION
TOTAL PERIMETER SOLUTION INTRODUCTION Since 1986 RBtec has been recognized as a leading technology company specializing in the design, development, and manufacturing of quality Outdoor Perimeter Detection
More information7638 Standish Place Derwood, MD Tel: (301) Fax: (301) Page 1 of 12. Website:
7638 Standish Place Derwood, MD 20855 Tel: (301) 760-4016 Fax: (301) 762-2253 Page 1 of 12 Website: www.rbtec.com E-Mail: info@rbtec.com Purpose The purpose of this document is to provide performance specifications
More informationTECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2
FEATURES: Closed Loop Design (Class A Wiring) Microprocessor Based System Intelligent Distributed System Structure Quick Response Time Fire Alarm in
More informationSC-F3G User Manual 1.0
SC-F3G User Manual 1.0 Table of Contents 1. Introduction... 3 2. Functions... 3 3. Features... 3 4. Package Contents... 3 5. Device Configuration... 4 6. Status LED signals... 5 7. Before You Start...
More informationJVA Electric Security Fence System. perimeter intruder detection system
JVA Electric Security Fence System perimeter intruder detection system Today's society has changed a lot over the previous years. Crime rate have gone up. Criminals have become bolder and more dangerous.
More informationACTIVE INFRARED BARRIER
Although PROTECH provides high security indoor intrusion sensors for the military and government markets, our specialty is outdoor protection. Since we first introduced our PIRAMID outdoor dual technology
More informationAPPLICATION DATA SHEET
APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors
More informationFC330A-ECO Auto-addressing analogue 1-Loop fire detection panel
FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel Synova TM Commissioning in no time thanks to automatic address allocation Auto-addressing makes setting dip switches unnecessary Automatic
More informationDifferent types of Fire Alarm System
Different types of Fire Alarm System Conventional Fire System Generally comes with Zones. Each zone can have max 20 detectors. Addressable Fire Alarm System This comes in loops. Different manufacturer
More informationAdaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV
CyCLO User Guide Version 2.00 19 th December 2017 REV 2.00 1 Contents 1. Hardware... 3 1.1. Introduction... 3 1.2. Electrical Specification... 3 1.3. Board Overview... 4 1.4. Electrical Installation...
More informationRLS-3060SH REDSCAN ULTIMATE
Quality detection system for video surveillance R REDSCAN ULTIMATE REDWALL Laser Scan Detector RLS-3060SH The REDSCAN RLS-3060 is an innovative laser scan detector. That identifies a moving object's size,
More informationRemote / Network Control for Rack Cabinet Access - DL Series
Remote / Network Control for Rack Access - DL Series Proximity Blue LED MiFARE Green LED MiFARE Green LED Proximity Blue LED level access security has become critically important for all data centers and
More informationSUPREMATouch Modular Fire & Gas Detection System
SUPREMATouch Modular Fire & Gas Detection System Because every life has a purpose Class Leading Fire & Gas Detection Solutions MSA s permanent gas detection systems are relied upon by a huge number of
More informationID2000. intelligent fire alarm panel
ID2000 6pp A4 10-01 3/8/06 22:57 Page 1 ID2000 intelligent fire alarm panel features Certified to EN54 Parts 2 and 4 Expandable from 2 to 8 loop capacity Up to 198 devices per loop (99 sensor and 99 modules)
More informationDanfoss gas detection unit Type GD Heavy Duty
Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx
More informationModel A1700 Series Annunciator
Seekirk Model A1700 Series Annunciator Applications: For usage in all types of process industries, electric generation, transmission and distribution, gas and water utilities. Features: The Seekirk model
More informationEC-BOS-602/616 AX Security
D a t a s h e e t EC-BOS-602/616 AX Security Comprehensive, easy-to-use Access Control management solution Overview The heart of EC-Net AX Security is the EC- BOS-602/616 AX Security, an advanced IP-based
More informationAir & Water Heat Pump R832
Figure 1 : R832 P.A. Hilton Ltd Air & Water Heat Pump R832 Vapour Compression Heat Pump that allows Performance Investigation from both Air and Water Sources. Rapid Stabilisation enables detailed Investigation
More informationSiemens Building Technologies Landis & Staefa Division. for central units OCI600 / OCI611 / OZW10 / OZW111 / OZW30 / OCI55
531 Alarm Software for central units OCI600 / OCI611 / OZW10 / OZW111 / OZW30 / OCI55 ACS900 Software for the reception of alarms and system reports from one or several communication centres MS Windows
More informationModel A2100 Series Annunciator
Seekirk Model A2100 Series Annunciator Applications: For usage within transformers, switchgear, breakers and/or within any processing equipment or control room applications either attended or unattended
More informationFor Complete Fire and Gas Solutions
Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable
More informationEnhanced FOUNDATION Fieldbus Physical Layer Diagnostics with the DeltaV System
November 2006 Page 1 Enhanced FOUNDATION Fieldbus Physical Layer Diagnostics This document provides possible solutions that allow enhanced Ff (FOUNDATION fieldbus) physical layer diagnostics using the
More informationLSM MANUAL PRINCIPLES OF LSM
Page 1 1.0 PRINCIPLES OF LSM 1.1. SYSTEM REQUIREMENTS: LSM 3.1 SP1 OR HIGHER (SUBJECT TO CHANGE) GENERAL Local administrator rights for installation Communication: TCP/IP (NetBios active), LAN (recommended:
More informationReliably Advanced Extinguishing Control
Reliably Advanced Extinguishing Control The Best Choice for Asset Protection What suppression and extinguishant control panel would you choose to protect the literary collection of an entire nation? 47
More informationDatasheet Face Recognition [Genetec VMS]
Datasheet Face Recognition [Genetec VMS] Version 3.6 This Specification Sheet gives the details of system requirements, features and other salient points of AllGoVision Face Recognition application for
More informationCHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM
CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi (P/N 10-068) is a state-of-the-art true intelligent digital peer-topeer modular suppression control system. It is ideal for
More informationClino Guard. Intelligent Life Care. Solutions for safe and efficient care
Clino Guard Intelligent Life Care Solutions for safe and efficient care Clino Guard more time for excellent care Rising costs, staff shortages and an aging society are just three of the many reasons why
More informationTranscom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure
TRANSCOM INSTRUMENTS Product Brochure Transcom Instruments Product Brochure TY800 Leaky Feeder Monitoring Module Overview GSM-Railway communication system operational quality is closely related to daily
More informationSetting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES
L i t r o n T o t a l L a s e r C a p a b i l i t y Setting the New Standard in Chiller Technology ±0. C ZEROPOINT CHILLER SERIES Litron s Zeropoint Series Setting the New Standard in Advanced Chiller
More informationAltanium Temperature Controllers
Designed to provide the industry s most consistent part quality Benefits 2 to 254 zones of control Simple and intuitive operation Interchangeable cards and interfaces across the entire product line Active
More informationFTS500 Series. Handheld OTDR Test Set.
www.opwill.com OTDR Tester is entirely new pad product released by OPWILL. It has rapid start technology and supports automatic and realtime test mode, which can guarantee engineers to examine and detect
More information