General Price List #2015-1

Size: px
Start display at page:

Download "General Price List #2015-1"

Transcription

1 General Price List # Effective February 1, 2015 Supersedes # Dated February 1, 2013 Minimum Order Billing - $50.00 Net + Freight The Protectowire Company, Inc. 60 Washington Street Pembroke, MA USA Tel Fax AN ISO 9001:2008 REGISTERED COMPANY pg. 1

2 GENERAL PRICE LIST # SUPERSEDES # DATED 2/1/13 SECTION 1 PROTECTOWIRE LINEAR HEAT DETECTOR ALL MODELS Standard Packaging Standard packaging consists of 500 ft. (152m) coils and 3,280 ft. (1,000m) spools depending upon model ordered. In general, smaller lengths of 500 ft. or less will be on coils, and longer lengths on spools. The exact length of wire per spool used to complete each order is at the sole discretion of the Factory. Our policy is to send as few spools/coils as possible based upon stock availability. Custom Lengths We can provide custom cut continuous lengths up to 3,280 ft. (1,000m). Limitations may apply depending upon specific model ordered. ADDITIONAL CHARGES MAY APPLY. CONSULT FACTORY. Messenger Wire Models Messenger wire reduces the maximum length of Protectowire that can be accommodated on a standard spool. Types EPC-M, PLR-M, XCR-M, and XLT-M are limited to 2,500 ft. (762m) per spool. Less than 500 FT. Custom cut lengths MODEL NO. DESCRIPTION < 500 FT. (152m) (PRICES/FOOT) Type EPC ALL MODELS (TEMP.) $2.70 Type EPC-M ALL MODELS (TEMP.) on Msg. Wire $3.00 Type XLT PHSC-135-XLT $2.80 Type XLT-M PHSC-135-XLT-M $3.10 Type PLR-R ALL MODELS (TEMP.) $2.80 Type PLR-R-M ALL MODELS (TEMP.) on Msg. Wire $3.10 Type XCR ALL MODELS (TEMP.) $3.00 Type XCR-M ALL MODELS (TEMP.) on Msg. Wire $3.30 PRICES ARE PER FOOT 500-4,999 ft. 5,000 9,999 ft. 10,000 ft. + TYPE EPC CONSTRUCTION (VINYL JACKET) (152-1,523 m) (1,524 3,047 m) (3,048 m +) PHSC-155-EPC Protectowire, Type EPC (155 F / 68 C) $2.60 $2.40 $2.20 PHSC-155-EPC-M Protectowire, Type EPC on Msg. Wire $2.90 $2.70 $2.50 PHSC-190-EPC Protectowire, Type EPC (190 F / 88 C) $2.60 $2.40 $2.20 PHSC-190-EPC-M Protectowire, Type EPC on Msg. Wire $2.90 $2.70 $2.50 PHSC-220-EPC Protectowire, Type EPC (220 F / 105 C) $2.60 $2.40 $2.20 PHSC-220-EPC-M Protectowire, Type EPC on Msg. Wire $2.90 $2.70 $2.50 PHSC-280-EPC Protectowire, Type EPC (280 F / 138 C) $2.60 $2.40 $2.20 PHSC-280-EPC-M Protectowire, Type EPC on Msg. Wire $2.90 $2.70 $2.50 PHSC-356-EPC Protectowire, Type EPC (356 F / 180 C) $2.60 $2.40 $2.20 PHSC-356-EPC-M Protectowire, Type EPC on Msg. Wire $2.90 $2.70 $2.50 TYPE XCR CONSTRUCTION (FLUOROPOLYMER JACKET) PHSC-155-XCR Protectowire, Type XCR (155 F / 68 C) $2.90 $2.80 $2.60 PHSC-155-XCR-M Protectowire, Type XCR on Msg. Wire $3.20 $3.10 $2.90 PHSC-190-XCR Protectowire, Type XCR (190 F / 88 C) $2.90 $2.80 $2.60 PHSC-190-XCR-M Protectowire, Type XCR on Msg. Wire $3.20 $3.10 $2.90 PHSC-220-XCR Protectowire, Type XCR (220 F / 105 C) $2.90 $2.80 $2.60 PHSC-220-XCR-M Protectowire, Type XCR on Msg. Wire $3.20 $3.10 $2.90 PHSC-280-XCR Protectowire, Type XCR (280 F / 138 C) $2.90 $2.80 $2.60 PHSC-280-XCR-M Protectowire, Type XCR on Msg. Wire $3.20 $3.10 $2.90 PHSC-356-XCR Protectowire, Type XCR (356 F / 180 C) $2.90 $2.80 $2.60 PHSC-356-XCR-M Protectowire, Type XCR on Msg. Wire $3.20 $3.10 $2.90 TYPE XLT CONSTRUCTION (VINYL POLYMER JACKET) PHSC-135-XLT Protectowire, Type XLT (135 F / 57 C) $2.70 $2.50 $2.20 PHSC-135-XLT-M Protectowire, Type XLT on Msg. Wire $3.00 $2.80 $2.50 PLR TYPE R CONSTRUCTION (THERMOPLASTIC ELASTOMER JACKET) PLR-155R Protectowire Universal, Type R (155 F / 68 C) $2.70 $2.50 $2.30 PLR-155R-M Protectowire Universal, Type R on Msg. Wire $3.00 $2.80 $2.60 PLR-190R Protectowire Universal, Type R (190 F / 88 C) $2.70 $2.50 $2.30 PLR-190R-M Protectowire Universal, Type R on Msg. Wire $3.00 $2.80 $2.60 Rev. 9/16/15 PLR Added pg. 2

3 GENERAL PRICE LIST # SUPERSEDES # DATED 2/1/13 SECTION 2 SRP-4x4 FIRE ALARM/RELEASING CONTROL PANEL MODEL NO. DESCRIPTION UNIT PRICE SRP-4x4 4 Zone Fire Alarm/Releasing Control Panel $1, SRP-4x4M 4 Zone Fire Alarm/Releasing Control Panel w/alarm Location Meter $2, RB-4 Alarm Relay Board with (4) SPDT Relays (Field Installed) $ AM-91-2 Dual Class A Output Module (Field Installed) $ BATTERIES AND BATTERY CABINETS PS AH, 12V (2 req d) Internally Mounts in SRP ea./$64.00 PS AH, 6V (4 req d) requires G-.5 Battery Cabinet when used with Model SRP-4x4M ea./$52.00 PS AH, 12V (2 req d) requires E-.5 Battery Cabinet when used with all SRP models ea./$ G-.5 Battery Cabinet use with 12AH size batteries $ E-.5 Battery Cabinet use with 18AH + size batteries $ SECTION 3 ALARM INITIATING DEVICES 5600 SERIES LOW PROFILE HEAT DETECTORS RATE OF RISE & FIXED TEMPERATURE (REPLACES 600 SERIES) 5601P Low Profile, Rate of Rise & Fixed Temp. 135 F $ Low Profile, Rate of Rise & Fixed Temp. 194 F $ Low Profile, Fixed Temperature 135 F $ Low Profile, Fixed Temperature 194 F $26.00 RATE ANTICIPATION HEAT DETECTORS (302 SERIES) 302-ET-135 All Weather Vertical Mounting 135 F $ ET-194 All Weather Vertical Mounting 194 F $ Interior Vertical Mounting 135 F $ Interior Vertical Mounting 194 F $ AW-135 Moisture or Dust Proof, Vertical Mounting 135 F $ AW-194 Moisture or Dust Proof, Vertical Mounting 194 F $ EPM-135 Explosion Proof Screw Base, Vertical Mounting 135 F* $ EPM-194 Explosion Proof Screw Base, Vertical Mounting 194 F* $ AP-P Adapter Plate for 4 Box for Models 302, 302-AW & 302-ET Detectors $16.00 * ½ conduit threads. Mount on threaded hub cover of Killark series JL fixture or equal. SMOKE DETECTORS FOR USE WITH PROTECTOWIRE FIRESYSTEM CONTROL PANELS SLR-24 Photoelectric Type, head only $68.00 SLR-24H Combination Smoke/Heat Detector, head only $78.00 NS6-220 Smoke Detector Base $16.00 Duct type Smoke Detectors Prices Available on Request Note: Use only 6VDC remote lamps with NS Series smoke detectors. SHARPEYE FLAME DETECTORS (STAINLESS STEEL HOUSING, FM/CSA/IECEx APPROVED, EXCLUDES MOUNTING BRACKET) UV DETECTORS 40/40U Ultraviolet Detector w/manual Test $2, /40UB Ultraviolet Detector w/built-in-test $2, UV/IR DETECTORS 40/40L UV/IR Dual Spectrum Detector w/manual Test $3, /40LB UV/IR Dual Spectrum Detector w/built-in-test $3, /40L4 UV/IR w/manual Test (4.5um) for Hydrocarbon Fires $3, /40L4B UV/IR w/built-in-test (4.5um) for Hydrocarbon Fires $3, /40UFL Ultra Fast UV/IR w/built-in-test $3, IR DETECTORS 40/40I IR3 Triple Infrared Detector w/built-in-test $4, /40M Multi-Spectrum IR Detector w/built-in-test for Long Range Hydrocarbon & Hydrogen Fires NOT AVAILABLE W/ALUMINUM HOUSING OPTION $4, /40R Single IR Detector $3, DETECTOR OPTIONS SPECIAL ORDER ATEX/IECEx Approval Add suffix C to Detector Model Number N/C Aluminum Housing SPECIAL ORDER Available only on ATEX/IECEx Approved Detectors Deduct $ from Detector prices shown SPECIAL ORDER Calibration to 85 C (185 F) $ Note: For SharpEye Models not listed, consult factory. E-.5 Price Correction 6/11/15 pg. 3

4 GENERAL PRICE LIST # SUPERSEDES # DATED 2/1/13 SECTION 3 ALARM INITIATING DEVICES CONTINUED ACCESSORIES MODEL NO. DESCRIPTION UNIT PRICE 40/ Tilt Mount for SharpEye 40/40 Models STAINLESS STEEL $ Duct Mount ALL MODELS EXCEPT 40/40R $ Air Shield for 40/40 Series $ Weather Cover (Stainless Steel) $ USB/RS485 Converter Kit for PC/Laptop USB Port, incl. Software for 40/40 Series $ / Flame Simulator IR3 $7, / Flame Simulator UV/IR & UV $7, / Flame Simulator Single IR $7, / Flame Simulator Multi-IR $7, / IR Beam Collimator IR3 (For extended test range) $ / UV/IR Beam Collimator UV-UV/IR (For extended test range) $ Laser Pointer $ Pole Mount (Stainless Steel / U-Bolt) 2 inches $ Pole Mount (Stainless Steel / U-Bolt) 3 inches $ Note: For SharpEye Models not listed, consult factory EXPLOSION PROOF / WEATHERPROOF MANUAL FIRE ALARM STATION SGX-32 SERIES SGX-32SK2 Single Action, Explosion Proof / Weatherproof (NEMA-4X) Manual Station w/dpdt Switch & Back Box. UL Listed, FM Approved SGX-32SK1 Double Action, Explosion Proof / Weatherproof (NEMA-4X) Manual Station w/dpdt Switch & Back Box. UL Listed, FM Approved $ $ MANUAL FIRE ALARM STATION SG-42 SERIES (SINGLE & DUAL ACTION) SG-42SK2 Single Action, SPST w/o Back Box *$42.00 SG-42SK1 Dual Action, SPST w/o Back Box *$49.00 SG-42CXK2 Single Action, (2) SPDT w/o Back Box *$ SGB-32S Surface Back Box for SG-42 MODELS $16.00 SG-WP NEMA-3R Weatherproof Back Box for SG-42 Series (NOT FOR SGX) $58.00 SG-GR Acrylic Break Rods (pkg. of 12) $14.00 Note: ALL UNITS INCLUDE SEPARATE SYSTEM RELEASE LABEL FOR EXTINGUISHING APPLICATIONS. *Qty. Discount Single model purchase of 10 or more units: SK2=$36.00 ea.; SK1=$41.00 ea.; CXK2=$97.00 ea. SECTION 4 ALARM INDICATING DEVICES ANNUNCIATORS (INDOOR & WEATHERPROOF) CUSTOMIZED LED AND GRAPHIC ANNUNCIATORS CAN BE PROVIDED. CONSULT FACTORY FOR DETAILS AND PRICING. WEATHERPROOF STROBE SIGNAL RSSWP-2475W-FR Visual Strobe Signal 75 Cd, 24VDC (Indoor/Outdoor) $92.00 WPSBB-R Weatherproof Back Box, Surface Mount - USE W/RSSWP ONLY $22.00 ELECTRONIC SIGNAL / STROBE MT-12/24-R Multitone Electronic Signal (less back box) $42.00 MT W-FR Multitone Electronic Signal w/strobe, 24VDC 15/75 Cd (ADA, less back box Indoor Only) $ MTWP-2475W-FR Multitone Electronic Signal w/strobe, 24VDC 75Cd Suitable for outdoor use with appropriate back box $ IOB-R Indoor / Outdoor Back Box $22.00 POWERTONE AMPLIFIED SPEAKER ASHP-24SMR Amplified Speaker w/o Tone Card $ U-TC Universal Tone Card - produces (32) different tones $ MOTORIZED ALARM BELLS 24VDC, POLARIZED W/TERMINALS MBA Alarm Bell 24VDC Polarized $46.00 MBA Alarm Bell 24VDC Polarized $52.00 MBA Alarm Bell 24VDC Polarized $60.00 WBB Weatherproof Back Box w/gasket $22.00 BB Back Box (Red) $16.00 pg. 4

5 pg. 5 GENERAL PRICE LIST # SUPERSEDES # DATED 2/1/13 SECTION 5 INSTALLATION ACCESSORIES COMMERCIAL TYPE ZONE / END-OF-LINE JUNCTION BOXES MODEL NO. DESCRIPTION UNIT PRICE ZB-4-QC-MP Non-metallic Moisture Proof Box w/compression terminals. Note: Use as End-of-Line Box for SRP-4x4 to mount 8.2K resistors supplied with panel. $38.00 ELR-4-QC-MP Non-metallic Moisture Proof EOL Box w/4.7k Res. For FS2000 & 2600HD Options B & BB/NO TEST SWITCH $42.00 ELR-4A Non-metallic Moisture Proof EOL Box (TRI-Wire) / NO TEST SWITCH. For FS2000 & 2600HD Options C & CC $42.00 SR-502 Strain Relief Connector $10.00 SR-502-N Non-Metallic Strain Relief Connector $6.00 HEAVY DUTY TYPE ZONE / JUNCTION BOXES ZB-HD-4-QC (N4X) Fiberglass NEMA-4X Type JIC Enclosure w/compression terminals $ SR-502 Strain Relief Connector $10.00 SR-502-N Non-Metallic Strain Relief Connector $6.00 HEAVY DUTY END-OF-LINE JUNCTION BOX W/TEST SWITCH (SRP-4x4 & 2600HD SERIES OPTIONS A & AA) ELR-HD-1A-QC (N4X) End of Line Fiberglass NEMA-4X Enclosure w/test Switch & Comp. Terminals, 8.2K Resistor $ SR-502 Strain Relief Connector $10.00 SR-502-N Non-Metallic Strain Relief Connector $6.00 HEAVY DUTY END-OF-LINE JUNCTION BOX W/TEST SWITCH (FS2000 SERIES & 2600HD SERIES OPTIONS B, BB, C & CC) ELR-HD-4-QC (N4X) End of Line Fiberglass NEMA-4X Enclosure w/test Switch & Compression Terminals (4.7K Resistor) $ ELR-HD-4A-QC (N4X) End of Line NEMA-4X Enclosure for TRI-Wire w/double Throw Test Switch & Compression Terminals (4.7K Resistor) $ SR-502 Strain Relief Connector $10.00 SR-502-N Non-Metallic Strain Relief Connector $6.00 WIRING ACCESSORIES PWSC Splicing Connectors (10/pk, SFTS Sealant Recommended) pack/$12.00 PWSC-3 3 Pole Splicing Connectors for TRI-Wire, (10/pk, SFTS Sealant Recommended) pack/$12.00 PWS Splicing Sleeves (10/pk) pack/$14.00 PWSK-3 Field Serviceable Splicing Connector Kit (consists of RSC-3U & RKC-3U) $28.00 SFTS #2228 Tape Sealant for Splice Connectors (1 x 10 makes approx. 30 splices) rl/$18.00 PFL Flexible Leads pr/$20.00 #35 WHITE Splicing Tape, white rl/$11.00 #35 RED Splicing Tape, red rl/$11.00 #35 BLUE Splicing Tape, blue rl/$ Splicing Tape, black (low temp. tape recommended for freezer applications) rl/$11.00 FASTENERS GENERAL PURPOSE APPLICATIONS WAW-N Clips, Corner, Nylon (white) $0.44 WAW-P Clips, Corner, Polypropylene (clear) $0.44 OHS-1 Clips, Line (use w/type EPR, EPC, EPN & TRI Protectowire) $0.52 OHS-SS 304 Stainless Steel Line Clip w ¼ Hole (use w/all types) $2.10 BC-2 Beam Clamp Assembly (steel) $2.60 BC-3P Iron Zinc Plated Beam Clamp Assembly (w/polypropylene clip) $3.00 BC-3N Iron Zinc Plated Beam Clamp Assembly (w/nylon clip) $3.00 RMC-2 L-Bracket (Rim Seal Type) $3.60 RMC-3 Stainless L-Bracket (Rim Seal Type) $12.00 TR-5G Insulated Standoff $5.20 EMS-A-CO Cable Mount (requires Sikaflex adhesive) $1.60 PLT1S-CO Cable Tie (for EMS-A-CO) $0.90 SIKAFLEX-291 Industrial Adhesive (for EMS-A-CO mounts) $34.00 CABLE TRAY APPLICATIONS HPC-2 Mounting Clip (Single Piece) $2.10 CC-2N Mounting Clip Assembly $2.10 CC-2W Mounting Clip Assembly $2.10 CC-10N Mounting Clip Assembly $2.60 CC-10W Mounting Clip Assembly $2.60 CC-10N-S Mounting Clip Assembly w/screw & lock nut $3.20 CC-10W-S Mounting Clip Assembly w/screw & lock nut $3.20

6 GENERAL PRICE LIST # SUPERSEDES # DATED 2/1/13 SECTION 5 INSTALLATION ACCESSORIES CONTINUED SPRINKLER PIPE MOUNTING MODEL NO. DESCRIPTION UNIT PRICE PM-3A Pipe Mounting Straps Nylon (3/4 to 2 pipe) $0.94 PM-3B Pipe Mounting Straps Nylon (2-1/2 to 3-1/2 pipe) $1.30 PM-3C Pipe Mounting Straps Nylon (4 to 6 pipe) $6.00 MESSENGER WIRE APPLICATIONS TR-4A Eyebolt $2.10 TR-24 Turnbuckle $5.60 TR-4A-S 304 Stainless Eyebolt $6.00 TR-24-S 304 Stainless Turnbuckle w/aluminum Body $13.00 TEST EQUIPMENT MFL-92 Fault Locator System $ APL-90 Protectowire Alarm Point Locator Meter Adapter $ WIRE INSTALLATION SPL-1L Spare Installation Spool, 3,280 ft. (1,000 m) $20.00 SPL-2M Spare Installation Spool, 1,500 ft. (456 m) $15.00 SPL-1S Spare Installation Spool, 500 ft. (152 m) $12.00 SU-15 Wire Dispensing Reel for Coils $ NOTE: Length indicated is maximum recommended for standard models. Lengths will be less for Messenger Wire models. SECTION 6 GENERAL TERMS & CONDITIONS Minimum Order: The minimum order is $50.00 net plus freight charges. Payment Terms: Net 30 Days for customers with established credit and The Protectowire Company s Credit Department Approval. Credit cards also accepted. Invoices not paid within 30 days, may affect your credit standing with Protectowire and delay processing of future orders. All payments must be made in U.S. Dollars. FOB Point: Pembroke, Massachusetts. All shipments are made Ex Works with freight added to Invoice. Returns: No returns will be accepted without a return authorization. All Non-Warranty returns are subject to a minimum 20% Restocking Charge to cover the cost of handling, inspection, and repacking. Products once installed or placed into service are not subject to return or exchange. Packaging: All orders will be carefully packaged in accordance with standard commercial practice. Requests for ocean freight and special packaging can be accommodated for an additional charge. Consult Factory for details and cost. Special Order Items: The Protectowire Company reserves the right to require a non-refundable deposit before ordering or manufacturing any special order items. Special Order Items are non-returnable and will not be accepted for credit or exchange. Shipping Dates: The Protectowire Company provides an Order Acknowledgement with Estimated Ship Date of every order accepted and processed. All shipping estimates are approximate and are not guaranteed. Failure to ship by the estimated ship date will not be considered sufficient cause for cancellation or damages. Order expediting and special handling may be subject to additional charges. Consult Factory for pricing. All clerical errors are subject to correction. pg. 6

7 2600HD Series Price List # Effective February 1, 2015 Supersedes # Dated March 1, 2013 Minimum Order Billing - $50.00 Net + Freight The Protectowire Company, Inc. 60 Washington Street Pembroke, MA USA Tel Fax AN ISO 9001:2008 REGISTERED COMPANY

8 2600HD PRICE LIST # SUPERSEDES # DATED HD Control Panels are designed for use in industrial applications and are the system of choice when custom engineering is required to meet special customer requirements or specifications. Enclosures are NEMA-4 rated (weatherproof/dustproof). SECTION HD CONTROL UNIT Complete documentation and system engineering are included in the prices shown. Consult the Factory for availability and pricing on special modifications or options which do not appear in this Price List. Basic 2600HD Industrial Control Units include the following: Complete power management, adjustable battery charger with monitor, ground fault detection, lamp test, two independent Class A/B (Style Z or Y) alarm notification appliance circuits, trouble silence resound timer. NEMA-4 rated enclosures with heavy duty field terminal strips must be ordered separately. See Section 4. ENCLOSURE MODEL NO. MODULE SPACES DESCRIPTION UNIT PRICE 2600HD System Control Unit with Protectowire Alarm Point Location Meter $4, HD2 9.0 System Control Unit without Protectowire Alarm Point Location Meter $3, HD System Control Unit with PCLC Touch Screen Color Graphic Display, Alarm Location Meter and Automatic Zone Alarm Scanner. NOTE: This System requires Input Modules with I/O Interface. Special functions may require special programming. Consult factory for details and pricing. $9, SPECIFY SYSTEM CONTROL UNIT INPUT AND BACK-UP POWER OPTION GC VAC Power Input with Gel Cell Battery Back-up STANDARD GC VAC Power Input with Gel Cell Battery Back-up N/C UC1 4.0 Universal Primary & Back-up Power Input (120/240VAC or 120/250VDC) Uninterruptible Second Source Back-up Power required $1, SECTION HD SERIES OPTIONS Select system Option Code letter(s) and show quantity. Note module space(s) required by each option in the system enclosure. ENCLOSURE OPTION CODE MODULE SPACES DESCRIPTION UNIT PRICE A 2.0 Two (2) Zone Class A Detection Module (HD1 & HD2 Systems Only) $ AA 2.5 Two (2) Zone Class A Detection Module w/i/o Interface (Use w/2600hd3 Only) $1, B 2.0 Four (4) Zone Class B Detection Module (HD1 & HD2 Systems Only) $ BB 2.5 Four (4) Zone Class B Detection Module w/i/o Interface (Use w/2600hd3 Only) $1, C * 2.0 TRI-Wire Two (2) Zone Class B Detection Module (HD1 & HD2 Systems Only) $ CC * 2.5 TRI-Wire Two (2) Zone Class B Detection Module w/i/o Interface (Use w/2600hd3 Only) $1, D Zone Alarm Location Meter Scanner 1 $1, D Zone Alarm Location Meter Scanner 1 $2, D Zone Alarm Location Meter Scanner 1 $3, E 2.0 Four (4) Circuit Class B Switch Supervisory Module (HD1 & HD2 Systems Only) $ EE 2.5 Four (4) Circuit Class B Switch Supervisory Module w/i/o Interface (Use w/2600hd3 Only) $1, F 2.0 Two (2) Circuit Class A Switch Supervisory Module (HD1 & HD2 Systems Only) $ FF 2.5 Two (2) Circuit Class A Switch Supervisory Module w/i/o Interface (Use w/2600hd3 Only) $1, G (1 st Barrier) Intrinsic Safety Barriers Class B Detection/Supervisory Circuits Only 2 $ NOTE: TRI-Wire Zones Require (2) Barriers per Zone (Ea. Add l) 1.0 H 1.0 Two (2) Circuit Solenoid Monitor & Release Module, 24VDC $ HH 1.0 Two (2) Circuit Solenoid Monitor & Release Module, for Star D Valve 24VDC $ J 1.5 Two (2) Circuit Solenoid Monitor & Release Module w/relays $ for 120VAC Solenoids JJ 2.5 Two (2) Circuit Solenoid Monitor & Release Module w/relays $1, for 250VDC Solenoids K 1.0 Audible Extender Module (2 Circuits/Module, Class A/B) $ L ---- Built-in Alarm Indicating Sonalert $ M 1.0 Auxiliary DPDT Alarm Relay, VAC or 28VDC $ N 1.0 Auxiliary DPDT Trouble Relay, VAC or 28VDC $ P 1.0 HD 4 Pole Relay, Ratings to 600VAC and 240VDC $ Q 1.5 HD 6 Pole Relay, Ratings to 600VAC and 240VDC $ R 1.5 HD 8 Pole Relay, Ratings to 600VAC and 240VDC $ S 0.5 Time Delay Relay Solid State.6 to 60 Sec. $ T ---- External NEMA-4X Key Operated Switches (Consists of Lamp Test, $1, Alarm Silence, Trouble/Supervisory Silence & System Reset) U ---- Battery Charging Meters (DC Volt and Amp) $ V 1.5 Auxiliary FWR Power Supply (APS-1 w/transformer, 5 Amp Max.) $ W 2.0 Auxiliary Regulated Power Supply w/aps-1 Module, 7 Amp Max. $1, This option not available on 2600HD2 or HD3 Systems. 2 This option not available with system ground fault detection. *THIS ITEM DISCONTINUED APRIL 1, 2015 PAGE 1

9 2600HD PRICE LIST # SUPERSEDES # DATED SECTION HD CUSTOM OPTIONS ENCLOSURE OPTION CODE MODULE SPACES DESCRIPTION UNIT PRICE GP Copper Ground Pad (Enclosure Mounted) $ HT VAC Control Panel Heater Assembly $ HT VAC Control Panel Heater Assembly $ NOTE: Leg Kits are available for some enclosure models. Consult factory for size limitations and pricing. SPECIAL WIRING PACKAGE INCLUDES CROSS-LINKED POLYETHYLENE FLAME RETARDANT PANEL WIRING & NUMBERED WIRE MARKERS SWP Special Wiring Package for EHD4230 Enclosures $ SWP Special Wiring Package for EHD4236 Enclosures $1, SWP Special Wiring Package for EHD4836 Enclosures $1, SWP Special Wiring Package for EHD6036 Enclosures $2, SWP-X ---- Special Wiring Package for Custom Sized Enclosures Exceeding $3, Module Spaces SECTION 4 EHD SERIES ENCLOSURES To determine the proper size enclosure, it is necessary to calculate the total space required by all system components. Begin by adding the number of module spaces required by the basic control unit and power input option in Section 1, and for the quantity of each option selected in Section 2. The sum of these numbers equal the total space required by the system you have configured. Select an enclosure whose total space capacity exceeds this number. If the total module spaces required for the system exceed the size of the largest enclosure, a custom sized enclosure is required. Consult Factory. ENCLOSURE MODEL NO. MODULE SPACES DESCRIPTION UNIT PRICE EHD Industrial Type-NEMA-4 Rated Enclosure $3, EHD Industrial Type-NEMA-4 Rated Enclosure $3, EHD Industrial Type-NEMA-4 Rated Enclosure $3, EHD Industrial Type-NEMA-4 Rated Enclosure $4, Due to the custom design features of the 2600HD Series and the potential for system variations requiring ancillary devices not accounted for by standard factory options, all 2600HD system enclosures estimated and/or ordered using this information are considered preliminary and are subject to change upon final Factory review. SECTION 5 E2600HD SERIES EXTENDER PANELS The zone capacity and optional features of the 2600HD Control Panel can be expanded after installation by utilizing an E2600HD System Extender Panel. In its basic form, the extender panel provides additional detection zones only. On large and more complex systems, the Extender can be configured to duplicate many of the same options contained in the main 2600HD Control Panel. ENCLOSURE MODEL NO. MODULE SPACES DESCRIPTION UNIT PRICE E2600HD1 2 System Extender for 2600HD1 Control Panel containing a $2, Protectowire Alarm Point Location Meter E2600HD2 2 System Extender for 2600HD2 Control Panel without a $1, Protectowire Alarm Point Location Meter E2600HD3 2 System Extender for 2600HD3 Control Panel containing a $2, Touch Screen PCLC Graphic Display Select the Option Code Letter(s) from those listed in Section 2 and show quantity. Determine the size of the Extender s enclosure by calculating the space required by all system components. Finalize complete E2600HD Extender Model Number and total price. SECTION 6 BATTERIES AND BATTERY CABINETS GEL CELL (SEALED LEAD ACID) STOCK AVAILABILITY MODEL NO. DESCRIPTION UNIT PRICE PS AH, 12V (2 req d) ea./$64.00 PS AH, 6V (4 req d) ea./$52.00 G-.5 Battery Cabinet for 1270 & 6100 batteries $ PS AH, 12V (2 req d) ea./$ PS AH, 12V (2 req d) ea./$ PS AH, 12V (2 req d) ea./$ PS AH, 12V (2 req d) ea./$ E-.5 Battery cabinet for 12180, 12335, & batteries $ Refer to 2600HD Battery Calculation Sheet, or consult Factory to determine proper battery size required for your particular system. PAGE 2

10 2600HD PRICE LIST # SUPERSEDES # DATED SECTION 7 OPERATION & MAINTENANCE MANUALS / DRAWINGS Prices for the above described equipment include submittal drawings up to four (4) prints corrected to the customer s requirements. Drawings may be ed upon request. Three (3) Operation & Maintenance Manuals and three (3) sets of final as built prints will be provided when the equipment is completed. Additional Material: Extra Manuals ea./$ Extra Prints ea./$40.00 SECTION 8 GENERAL TERMS & CONDITIONS Minimum Order: The minimum order is $50.00 net plus freight charges. Payment Terms: Net 30 Days for customers with established credit and The Protectowire Company s Credit Department Approval. Credit cards also accepted. Invoices not paid within 30 days, may affect your credit standing with Protectowire and delay processing of future orders. All payments must be made in U.S. Dollars. FOB Point: Pembroke, Massachusetts. All shipments are made Ex Works with freight added to Invoice. Returns: No returns will be accepted without a return authorization. All Non-Warranty returns are subject to a minimum 20% Restocking Charge to cover the cost of handling, inspection, and repacking. Products once installed or placed into service are not subject to return or exchange. Packaging: All orders will be carefully packaged in accordance with standard commercial practice. Requests for ocean freight and special packaging can be accommodated for an additional charge. Consult Factory for details and cost. Special Order Items: The Protectowire Company reserves the right to require a non-refundable deposit before ordering or manufacturing any special order items. Special Order Items are non-returnable and will not be accepted for credit or exchange. Shipping Dates: The Protectowire Company provides an Order Acknowledgement with Estimated Ship Date of every order accepted and processed. All shipping estimates are approximate and are not guaranteed. Failure to ship by the estimated ship date will not be considered sufficient cause for cancellation or damages. Control Panel Order Cancellation: A charge will be applied to any formally acknowledged control panel order which is cancelled once engineering design and/or production has begun. The cancellation charge will include all charges incurred up to the date of cancellation. In all cases, the minimum cancellation charge shall be 20% of the net control panel price. Order expediting and special handling may be subject to additional charges. Consult Factory for pricing. All clerical errors are subject to correction. PAGE 3

11 FS2000 Series Price List # Effective February 1, 2015 Supersedes # Dated March 1, 2013 Minimum Order Billing - $50.00 Net + Freight The Protectowire Company, Inc. 60 Washington Street Pembroke, MA USA Tel Fax AN ISO 9001:2008 REGISTERED COMPANY

12 FS2000 PRICE LIST # SUPERSEDES # DATED 3/1/13 SECTION 1 FIRESYSTEM 2000 CONTROL UNIT SYSTEM CONTROL UNIT: Standard Units include main mother board with control card, Class A/B detection zone card(s) (except FS2000), two Class B audible circuits, ground fault detection, lamp test, and power supply with battery charger and monitor. ENCLOSURES MUST BE SIZED AND PRICED SEPARATELY. MODEL NO. ENCLOSURE MODULE SPACES DESCRIPTION UNIT PRICE FS2000 * 1/2 Basic Control Unit w/o Zone $1, Card (Requires Option X or XX) FS zones $1, FS /2 4 zones (1) $1, FS zones (1) $1, FS /2 8 zones (2) $2, FS zones (2) $2, FS /2 12 zones (3) $3, FS zones (3) $3, FS /2 16 zones (4) $3, FS zones (4) $4, FS /2 20 zones (5) $4, FS zones (5) $4, FS /2 24 zones (6) $5, FS zones (6) $5, FS /2 28 zones (7) $6, FS zones (7) $6, FS /2 32 zones (8) $6, FS zones (8) $6, FS /2 36 zones (9) $7, FS zones (9) $7, FS /2 40 zones (10) $8, FS zones (10) $8, FS /2 44 zones (11) $8, FS zones (11) $9, *THIS ITEM TO BE DISCONTINUED APRIL 1, 2015 SECTION SERIES OPTIONS Select Option Code letter and show quantity when necessary. Options which require enclosure module space(s) must be added to the module space required for the basic panel to determine final enclosure size. ENCLOSURE OPTION CODE MODULE SPACES DESCRIPTION UNIT PRICE A ---- PDM Protectowire Alarm Location Meter 2 zones $1, A PDM Protectowire Alarm Location Meter 4 zones $1, A PDM Protectowire Alarm Location Meter 6 zones $1, A PDM Protectowire Alarm Location Meter 8 zones $1, A PDM Protectowire Alarm Location Meter 10 zones $1, For systems larger than 10 zones, determine Option A price by adding meter switching charge to base option price. When ordering, state number of zones after option code letter as shown above. 1. Base option price $ Switching charge No. of metered Protectowire zones x $ Note: switching charge is based on even number zone increments only i.e. 12, 14, 16, etc. and must include all RS-1 Release Module (Option F) initiating circuits used as Protectowire detection zones. C 1 16 Zone alarm scanner requires Option A $1, C Zone alarm scanner requires Option A $2, C Zone alarm scanner requires Option A $3, D 1/2 Water Flow Detection Zones (2/card) $ E 1/2 Switch Supervisory Circuits Class A/B (2 circuits/card) $ F 1/2 Solenoid release module w/class B initiating circuit $ (1 release & 1 initiating circuit/module) PAGE 1

13 FS2000 PRICE LIST # SUPERSEDES # DATED 3/1/13 SECTION SERIES OPTIONS CONTINUED ENCLOSURE OPTION CODE MODULE SPACES DESCRIPTION UNIT PRICE H ---- Intrinsic safety barrier (Shunt Diode) for Class B detection ckts. $ (1-2 zones) 0 Disables system ground fault detection circuit. (3-16 zones) 1 Add qty. of zones required to option code letter and determine (17-32 zones) 2 module space based upon zone qty. shown in brackets. J * ---- Intrinsic safety barriers for Class B TRI-Wire det. ckts. (2/zone) $ (1 zone) 0 Disables system ground fault detection circuit. (2-8 zones) 1 Add qty. of zones required to option code letter and determine (9-16 zones) 2 module space based upon zone qty. shown in brackets. (17-24 zones) 3 K ---- Intrinsically safe dual channel DC Isolator for two (2) Class B detection ckts. $ (1-4 zones) 0 Not compatible with Meter Option A. Isolates det. ckt. from (5-32 zones) 1 system ground fault detector. Size restrictions limit use of Option K to LTi Systems Only. L ---- Auxiliary Zone Alarm Relay - SPDT $90.00 LL ---- Auxiliary Zone Alarm Relay - DPDT $ P ---- Battery Charging Meters $ Q ---- Time Delay Relay $ R ---- Auxiliary Common Alarm Relay - DPDT $ RR ---- Auxiliary Relay Module (8-SPDT Relays) $ S ---- Auxiliary Common Trouble Relay - DPDT $ T ---- Class A Audible Circuits (main panel, general alarm only) $ U 1/2 Alarm Expander Card (1 audible circuit, Class A or B) $ V ---- Zone Voting Module (ZV-91) $ W ---- Auxiliary Power Supply (PS-2) $ X * 1/2 Dual Temp. Class B Detection Zones (2/card) $ XX * 1/2 Dual Temp. Class A Detection Zone (1/card) $ Y ---- Power Conditioning Module (PS-95) $ Z ---- External NEMA-4X Key Operated System Control Switches - $ Alarm Silence, Trouble/Supv. Silence, Reset & Lamp Test. Not available with LTi2X Enclosure *OPTIONS J, X AND XX TO BE DISCONTINUED APRIL 1, 2015 SECTION 3 EN SERIES ENCLOSURES To determine the proper size enclosure, add the module spaces required for the basic control unit plus the module spaces required for the quantity of each option selected from the Option List. Select the enclosure from the sizes shown below. If total module space required for the system exceeds the size of the largest enclosure, a second extender enclosure will be required. Select two enclosures whose total module capacity equal or exceed that required for the system. MODEL NO. DESCRIPTION UNIT PRICE EN2 Two module enclosure (standard beige textured finish) $ EN4 Four module enclosure (standard beige textured finish) $ EN6 Six module enclosure (standard beige textured finish) $ EN9 Nine module enclosure (standard beige textured finish) $ EN12 Twelve module enclosure (standard beige textured finish) $1, EN2R Two module enclosure (red textured finish) $ EN4R Four module enclosure (red textured finish) $ EN6R Six module enclosure (red textured finish) $ EN9R Nine module enclosure (red textured finish) $ EN12R Twelve module enclosure (red textured finish) $1, LTi INDUSTRIAL ENCLOSURES LTi2X Two module Type 4X fiberglass enclosure (red) $ LTi4 Four module Type 4 heavy duty steel enclosure (red textured finish) $1, LTi6 Six module Type 4 heavy duty steel enclosure (red textured finish) $1, LTi9 Nine module Type 4 heavy duty steel enclosure (red textured finish) $1, NOTE: HEATERS REQUIRE ADDITIONAL MODULE SPACE CONSULT FACTORY HT-1 115VAC Control Panel Heater Assembly $ HT-2 230VAC Control Panel Heater Assembly $ PAGE 2

14 FS2000 PRICE LIST # SUPERSEDES # DATED 3/1/13 SECTION 4 BATTERIES AND BATTERY CABINETS GEL CELL (SEALED LEAD ACID) STOCK AVAILABILITY MODEL NO. DESCRIPTION UNIT PRICE PS AH, 12V (2 req d) ea./$64.00 PS AH, 6V (4 req d) ea./$52.00 PS AH, 12V (2 req d) Note: Fits EN4 or larger only ea./$ Battery Models shown above are designed for mounting inside the EN Series Enclosures. LTi enclosures require a separately ordered battery cabinet. Consult factory for information concerning enclosure venting for internal battery placement. The following batteries require a separately ordered battery cabinet: PS AH, 12V (2 req d) ea./$ PS AH, 12V (2 req d) ea./$ E-.5B Battery cabinet (textured beige) for & batteries $ E-.5 Battery cabinet (red) for & batteries $ Note: Refer to Gel Cell Battery Selection Data Sheet 8967B or consult factory to determine proper battery size for your particular system. SECTION 5 EXPANSION/REPLACEMENT MODULES All module orders must reference the original system s Drawing Number/PWC Job Number or Serial Number. Orders for EB-91 Expander Boards and RS-91 Release Modules must specify the module s connector gender (i.e. male/female) for proper placement within existing systems. EB and RS modules with suffix A are not gender specific. Orders received without this information cannot be processed. Consult the factory for assistance. MB-91 MB-91A* Main Master Board w/o Meter Interface $ MB-91M MB-91AM* Main Master Board w/meter Interface $ CC-91 CC-91A* Control Card w/test Feature (DISCONTINUED USE CC-91NT or ANT) CC-91NT CC-91ANT* Control Card w/o Test Feature $ CC-91I CC-91AI* Control Card w/isb Interface $ CC-91INT CC-1AINT* Control Card w/isb Interface & No Test $ ZC-91 ZC-91A* Class A/B Detection Zone Card (2 zones/card w/o meter interface) $ ZC-91M ZC-91AM* Class A/B Detection Zone Card (2 zones/card w/meter interface) $ ZC-95 3-Wire Dual Temp. Class B Zone Card (2 zones/card) $ ZC-95M 3-Wire Dual Temp. Class B Zone Card (2 zones/card w/meter interface) $ ZI-91 ZI-91A* Class B Detection Zone Card (2 zones/card w/isb interface) $ Zl-91M ZI-91AM* Class B Detection Zone Card (2 zones/card w/meter & ISB interface) $ ZI-91AW* Class B Water Flow Zone Card (2 zones/card w/isb interface) $ SC-91 SC-91A* Class A/B Supervisory Module (2 circuits/card) $ SC-91ANL* Class A/B Supervisory Module, non-latching (2 circuits/card) $ SC-91AI* Class B Supervisory Module (2 circuits/card w/isb interface) $ ZC-91W ZC-91AW* Class A/B Water Flow Zone Card (2 zones/card) $ EB-91 EB-91A* Expander Board accepts (2) plug-in zone cards (w/o meter interface) $ EB-91M EB-91AM* Expander Board accepts (2) plug-in zone cards (w/meter interface) $ RS-91 Solenoid Monitor & Release Module with Switch Supervisory $ (2 release & 2 supervisory circuits/module) RS-1* Solenoid Release/Initiating Device Card (1 release/1 Class B circuit/card) $ RS-91D Solenoid Monitor & Release Module for Star Model D with Switch Supervisory $ (2 release & 2 supervisory circuits/module) AE-91 Alarm Expander Card 1 audible circuit, Class A or B (SPECIFY LATCHING/NON-LATCHING) $ AM-91 Class A Audible Circuits (Option T) $ PS-91 Auxiliary Power Supply Less Transformer (Option W) $ SP * PS-2 Auxiliary Power Supply (Option W) $ ZV-91-2 Zone Voting Module activates on 2 inputs (Option V) $ ZV-91-3 Zone Voting Module activates on 3 inputs (Option V) $ PS-95 Power Conditioning Module (Option Y) $ RB-98 Relay Module 8-SPDT, 24VDC (Option RR) $ *Replacements for systems assembled after July 1, 2010 consult factory. MISCELLANEOUS PANEL LABELS CUSTOM ENGRAVED CONTROL PANEL LABELS (PRICES PER ORDER) One Label $40.00 Each Additional Label $6.00 SYSTEM MANUALS & DRAWINGS One manual and one internal wiring diagram is provided with each control panel. Additional copies are priced as follows: Operation & Maintenance Manual Internal Wiring Diagram (IWD) $40.00 ea. $30.00 ea. PAGE 3

15 FS2000 PRICE LIST # SUPERSEDES # DATED 3/1/13 SECTION 6 GENERAL TERMS & CONDITIONS Minimum Order: The minimum order is $50.00 net plus freight charges. Payment Terms: Net 30 Days for customers with established credit and The Protectowire Company s Credit Department Approval. Credit cards also accepted. Invoices not paid within 30 days, may affect your credit standing with Protectowire and delay processing of future orders. All payments must be made in U.S. Dollars. FOB Point: Pembroke, Massachusetts. All shipments are made Ex Works with freight added to Invoice. Returns: No returns will be accepted without a return authorization. All Non-Warranty returns are subject to a minimum 20% Restocking Charge to cover the cost of handling, inspection, and repacking. Products once installed or placed into service are not subject to return or exchange. Packaging: All orders will be carefully packaged in accordance with standard commercial practice. Requests for ocean freight and special packaging can be accommodated for an additional charge. Consult Factory for details and cost. Special Order Items: The Protectowire Company reserves the right to require a non-refundable deposit before ordering or manufacturing any special order items. Special Order Items are non-returnable and will not be accepted for credit or exchange. Shipping Dates: The Protectowire Company provides an Order Acknowledgement with Estimated Ship Date of every order accepted and processed. All shipping estimates are approximate and are not guaranteed. Failure to ship by the estimated ship date will not be considered sufficient cause for cancellation or damages. Control Panel Order Cancellation: A charge will be applied to any formally acknowledged control panel order which is cancelled once engineering design and/or production has begun. The cancellation charge will include all charges incurred up to the date of cancellation. In all cases, the minimum cancellation charge shall be 20% of the net control panel price. Order expediting and special handling may be subject to additional charges. Consult Factory for pricing. All clerical errors are subject to correction. PAGE 4

Commercial and Light Industrial Fire Alarm Control Panel

Commercial and Light Industrial Fire Alarm Control Panel FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel Features Easily expandable. All new plug-in board design Two supervised audible circuits Lamp and system trouble circuit test Ground

More information

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel PROTECTOWIRE FireSystems Features Easily expandable Two supervised audible circuits Lamp and system trouble circuit test Ground fault detection Initiating device circuit (IDC) alarm test Monitors up to

More information

FireSystems PROTECTOWIRE. Installing Protectowire Linear Heat Detector

FireSystems PROTECTOWIRE. Installing Protectowire Linear Heat Detector PROTECTOWIRE FireSystems Installing 1. Purpose The purpose of this guide is to ensure coverage of the area to be protected in accordance with accepted fire protection principles and to assure uniform installations.

More information

Installing Protectowire Linear Heat Detector

Installing Protectowire Linear Heat Detector PROTECTOWIRE FireSystems 1. Purpose The purpose of this guide is to ensure coverage of the area to be protected in accordance with accepted fire protection principles and to assure uniform installations.

More information

FIRE DETECTION CONTROL PANEL OPERATING & MAINTENANCE MANUAL

FIRE DETECTION CONTROL PANEL OPERATING & MAINTENANCE MANUAL FIRE DETECTION CONTROL PANEL OPERATING & MAINTENANCE MANUAL APPROVED An ISO 9001 Registered Company IMPORTANT SERVICE NOTICE When requesting service assistance, or to order parts for this control panel,

More information

PRODUCT CATALOG.

PRODUCT CATALOG. PRODUCT CATALOG www.statx.com The Stat-X product offerings cover a wide range of enclosed special hazard fire protection applications, and we also offer a personal protection device, the Stat-X First Responder

More information

PRODUCT CATALOG.

PRODUCT CATALOG. PRODUCT CATALOG www.statx.com The Stat-X product offerings cover a wide range of enclosed special hazard fire protection applications, and we also offer a personal protection device, the Stat-X First Responder

More information

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906 s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones

More information

Conventional Releasing Control Panel

Conventional Releasing Control Panel s Data Sheet Fire Safety Products Conventional Releasing Control Panel Pre-Action Deluge Agent-Releasing Fire System Model TXR-320 Remote configurable Up to two (2) hazard areas Operable with the following:

More information

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger Flame 2350 (UV&IR) Flame Detection Dräger Flame 2350 (UV&IR) Flame Detection The Dräger Flame 2350 combines UV and IR sensors for the detection of hydrocarbon-based fires. This combination of sensors offers you more security and fewer false

More information

Dräger Flame 2100 (UV) Flame Detection

Dräger Flame 2100 (UV) Flame Detection Dräger Flame 2100 (UV) Flame Detection A short response time and high reliability against false alarms are the features of the Dräger Flame 2100. Its UV sensor is quick to detect hydrocarbon- or hydrogen-based

More information

Dräger Flame 2500 (IR3) Flame Detection

Dräger Flame 2500 (IR3) Flame Detection Dräger Flame 2500 (IR3) Flame Detection With its triple IR sensor The Dräger Flame 2500 detects hydrocarbonbased fires even over greater distances. Moreover, it offers a high reliability against false

More information

Reference Guide 2.1. Certificate Number

Reference Guide 2.1. Certificate Number SAFE Reference Guide 2.1 This reference guide provides general information for the installation, servicing, and maintaining of a Linear Heat Detection System. For more detail, please refer to the Installation

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

Dräger Flame 2370 (UV&IR) Flame Detection

Dräger Flame 2370 (UV&IR) Flame Detection Dräger Flame 2370 (UV&IR) Flame Detection An extremely short response time and very high reliability against false alarms are the features of the Dräger Flame 2370. It is quick and reliable in detecting

More information

The SharpEye 40/40I (IR3) Flame Detection

The SharpEye 40/40I (IR3) Flame Detection The SharpEye 40/40I (IR3) Flame Detection combine state-of-the-art technology with rugged durability and be ready to reliably work in any situation. Dräger offers a wide variety of high-quality flame-detectors

More information

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014 January 16, 2014 Release Control Panel 290a 1. Description The Viking VFR400 is a microprocessor based releasing control panel for use on preaction, deluge, Surefire, Firecycle multicycle sprinkler systems,

More information

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger Flame 2700 (Multi-IR) Flame Detection Dräger Flame 2700 (Multi-IR) Flame Detection With its multichannel IR sensor the Dräger Flame 2700 detects hydrocarbon- and hydrogen-based fires. Thereby it offers a high reliability against false alarms.

More information

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS PXL Conventional Zone Fire Alarm Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS 12 Zone System Expandable to 32 10 Amp Base Power Supply Multiple Power Supplies Available - Local or Remote 4 Notification

More information

Building Name: Our Lady of Sorrows Date: July 10, 2013

Building Name: Our Lady of Sorrows Date: July 10, 2013 1 E1. FIRE ALARM SYSTEM ANNUAL TEST AND INSPECTION REPORT (Reference: 5.1.2) Building Name: Our Lady of Sorrows Date: July 10, 2013 Address 19 Mohns Avenue Petawawa, ON System Manufacturer: Siemens Model

More information

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep. 140 58th St. Brooklyn, NY Power Supply/Chargers Installation Guide Models Include: eflow4n/eflow4nx - 4 amp @ 12VDC or 24VDC eflow4n8/eflow4nx8 eflow4n8d/eflow4nx8d - 4 amp @ 12VDC or 24VDC - 4 amp @ 12VDC

More information

The following information shall become and form part of the contract documents.

The following information shall become and form part of the contract documents. October 4, 206 To: Attention: Re: All Bidders All Bidders JCBE Gymnasium HVAC Upgrades BC#: 206433 Edmonds Project No.: BHM6090 All bidders, The following information shall become and form part of the

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

ThermoCable Linear Heat Detection System

ThermoCable Linear Heat Detection System ThermoCable Linear Heat Detection System Estimating Guide 1. INTRODUCTION 1.1 Linear Heat Detection ThermoCable digital linear heat detection wire is a combination of advanced polymer and digital technologies

More information

CM800 Emergency Call System

CM800 Emergency Call System Submittal Package as of 5/25/2017 Phone: 828.524.9967 Toll-Free: 800.327.8466 Sales: Option 2 Tech Support: Option 3 324 Industrial Park Road Franklin, NC 28734 tektone@tektone.net Fax: 828.524.9968 Copyright

More information

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION 1. GENERAL SPECIFICATION 1.1 The contractor shall provide an Intelligent AlarmLine Linear Heat Detection System to perform the following functionality: A. Fire Alarm, Supervisory and Trouble-Event Initiation

More information

30.45 Electric Release PDRP-2001

30.45 Electric Release PDRP-2001 The PDRP-2001 Fire Alarm Control Panel (FACP) is a six-zone control panel for single and dual hazard deluge and preaction applications. The FACP is compatible with conventional input devices (2-wire or

More information

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum. September 29, 1997 Firecycle III 433 a 1. PRODUCT NAME VIKING Model E-1 Manufactured 1997 Present 2. MANUFACTURED FOR THE VIKING CORPORATION 210 N Industrial Park Road Hastings, Michigan 49058, U.S.A.

More information

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL SECTION 1 - GENERAL CONDITIONS I. SCOPE: This specification outlines the requirements for a Fike Micromist Water Mist Fire Suppression System with automatic detection and control. The work described in

More information

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL THE GAMEWELL COMPANY PN: 71981 60 PLEASANT STREET ISSUE A ASHLAND, MA 01721 3/22/2001 This page intentionally blank ii

More information

Dräger Flame 2100 Flame Detection

Dräger Flame 2100 Flame Detection Dräger Flame 2100 Flame Detection Working in areas with combustible gases, vapors, or materials requires fire/ flame detection as a life-saving necessity. The best solutions must combine state-of-the-art

More information

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection The SharpEye 40/40L4-L4B (UV/IR) Flame Detection requires fire/flame detection as a life-saving necessity The best solutions must combine state-of-the-art technology with rugged durability and be ready

More information

Across-the-Line SERIES MP300 Combined Manual and Automatic

Across-the-Line SERIES MP300 Combined Manual and Automatic Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps

More information

Release Control Fire Alarm Systems

Release Control Fire Alarm Systems SYSTEM ABORT PUSH AND HOLD COIL SUPERVISION MODULE (2 AMP) 2081-9046 RED INSTALLATION INSTRUCTIONS 574-437 REV YEL NAC+ MAINTAIN 1/4" SEPARATION BETWEEN POWER LIMITED (RED/) AND NONPOWER S LIMITED (YEL/)

More information

AL600ULADA. NAC Power Extender. Installation Guide

AL600ULADA. NAC Power Extender. Installation Guide AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery

More information

Linear Heat Detection for Coal Conveyors. Application Guide

Linear Heat Detection for Coal Conveyors. Application Guide Linear Heat Detection for Coal Conveyors Application Guide K-73-203 Rev AA December 2014 INTRODUCTION One of the most common causes of Coal Conveyor belt fires is the overheating of the conveyor idler

More information

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R Region Project Page 1 PART 1 - GENERAL 1.1 REFERENCES.1 CAN/ULC-S524-2006, Standard for the Installation of Fire Alarm Systems..2 CAN/ULC-S525-2007, Audible Signal Device for Fire Alarm Systems..3 CAN/ULC-S526-2007,

More information

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep. Power Supply/Chargers Installation Guide Models Include: eflow4na8d - 4A @ 12VDC or 24VDC - Eight (8) PTC Outputs eflow6na8d - 4A @ 12VDC or 24VDC - Eight (8) PTC Outputs eflow102na8d - 10A @ 12VDC - Eight

More information

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.

More information

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES USER INSTRUCTIONS FOR THE CHEMGARD INFRARED GAS MONITOR SERIES To completely customize the specification to your exact application, modification to the

More information

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep. Power Supply/Chargers Installation Guide Models Include: eflow4na8-4a @ 12VDC or 24VDC - Eight (8) Fused Outputs eflow6na8-4a @ 12VDC or 24VDC - Eight (8) Fused Outputs eflow102na8-10a @ 12VDC - Eight

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 042010 Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger Installation Guide for AL300ULM Multi-Output Access Control Power Supply Charger R AL300ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL300ULM multi-output access control power supply/charger

More information

Soft Start Series MP700 Solid State, Reduced Voltage

Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s

More information

SP-1000X. Panic Device Power Controller Installation Guide. Rev

SP-1000X. Panic Device Power Controller Installation Guide. Rev TM SP-1000X Panic Device Power Controller Installation Guide Rev. 120213 Overview: SP-1000X will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed to handle the high current

More information

Model 4001 Series Single Channel Controller

Model 4001 Series Single Channel Controller Model 4001 Series Single Channel Controller Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 (800) 727-4377 (408) 262-9042 - Fax E-Mail: sales@sierramonitor.com Web site:

More information

AlarmLine Linear Heat Detector

AlarmLine Linear Heat Detector 7.01 7/11/2000 8:1 AM Page 1 CP Scan#1:Desktop Folder:hold:90 Catalog:7.01.job: 7.01 AlarmLine Linear Heat Detector FEATURES Integrating Type Linear Heat Detector Analog Sensing Field Adjustable Alarm

More information

Installation Guide for models:

Installation Guide for models: 140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal11F - Power Supply 1: 12VDC @ 3.3 amp or 24VDC @ 3.6 amp. - Power Supply 2: 12VDC @ 3.3 amp

More information

Vista-50P/-50PUL System Design Sheet

Vista-50P/-50PUL System Design Sheet Vista-50P/-50PUL System Design Sheet INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO ACCESS CONTROL SECTION 1: Basic Vista-50P (Nine Hardwired Zones, One Addressable Loop, Wireless)

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 031703 Overview: The Altronix AL802ULADA is an extremely cost effective 8 amp voltage regulated

More information

The SharpEye 40/40M (Multi IR) Flame Detection

The SharpEye 40/40M (Multi IR) Flame Detection The SharpEye 40/40M (Multi IR) Flame Detection requires fire/flame detection as a life-saving necessity The best solutions must combine state-of-the-art technology with rugged durability and be ready to

More information

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES POWER SUPPLY AND BATTERY CHARGER AC AND DC STATUS INDICATORS ENOUGH POWER TO SUPPORT UP TO 3 MAGLOCKS OR ELECTRIC STRIKES PLUS REQUIRED

More information

PURGE/PRESSURIZATION SYSTEM

PURGE/PRESSURIZATION SYSTEM PROCESS AUTOMATION PURGE/PRESSURIZATION SYSTEM DATA SHEETS Systems ( Series) 2001A: Class I Volumes 2 ft 3 and Class II Volumes 10 ft 3...3 2001B: Class II Volumes 50 ft 3...7 2001C: Class II Volumes 250

More information

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10 Belleville, Ontario Page 1 of 10 1 GENERAL 1.1 GENERAL REQUIREMENTS.1 The General Conditions of CCDC2-2008, and the General requirements of Division 1, form part of this Section and must read in conjunction

More information

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control File: S8485 Wiring Diagram This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control Panel. The operation of this product is intended for indoor

More information

FEC400 Series. Installation Manual

FEC400 Series. Installation Manual FEC400 Series Conventional microprocessor controlled fire detection and alarm panels with extinguishing control Installation Manual Version 2.3 / August 2004 Aritech is a GE Interlogix brand. http://www.geindustrial.com/ge-interlogix/emea

More information

Vista-128FB System Design Sheet

Vista-128FB System Design Sheet Vista-128FB System Design Sheet FIRE DETECTION SPRINKLER SUPERVISION INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO ACCESS CONTROL SECTION 1: Basic Vista-128FB (Eight Hardwired Zones,

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL S E R I A L N O. M O D E L N O. T e m p. R a n g e 1 - = > 6 0 o F 2 - = 4 0-6 0 o F 3 - = < 4 0 o F - G a s T y p e 1 - R -1 1 2

More information

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi (P/N 10-068) is a state-of-the-art true intelligent digital peer-topeer modular suppression control system. It is ideal for

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM Description Mircom s FleX-Net TM Series Network Fire Alarm Control Panels offer modular components to meet a wide variety of applications. Designed for peerto-peer

More information

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5 Construction Standards Page 1 of 5.1 General Description.1 The University requires that all new fire alarm system control panel, components, and devices, as required for the project, be Secutron 2900 Series

More information

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM OSU PROJECT NO. 30-04-15 PAGE 1 PART 1 GENERAL 1.1 WORK INCLUDED A. Provide all labor, materials, and equipment required to provide a complete and operating system of manual and automatic detection devices,

More information

Installation Guide for models:

Installation Guide for models: 140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal3FD - 12VDC @ 4.6 amp or 24VDC @ 5.2 amp. - Sixteen (16) PTC protected power-limited outputs.

More information

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE Cerberus PRO Marine Fire and Detection Equipment s FH-2071-UM, BP-62 and USCG-HPLATE Cerberus PRO Fire Safety Products ARCHITECT AND ENGINEER SPECIFICATIONS Marine equipment is used with Cerberus PRO 252-point

More information

Dräger Flame 2500 Flame Detection

Dräger Flame 2500 Flame Detection Dräger Flame 2500 Flame Detection Working in areas with combustible gases, vapours or materials requires fire/ flame detection as a life-saving necessity. The best solutions must combine state-of-the-art

More information

FDF Foam Pump Controllers Features

FDF Foam Pump Controllers Features FDF100 Diesel Engine Foam Pump Controllers 1-1 Product Description The FDF Series of Foam Pump Controllers are designed for use with foam concentrate injection, foam transfer and water mist systems for

More information

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description FIREFLEX VACTEC description This FIREFLEX VACTEC integrated fire protection system consists of a vacuum system trim totally pre-assembled, prewired and factory tested. All electrical and mechanical components

More information

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors. Fire Sentry Corporation (FSC) 593 Apollo Street Tel.: 714-671-1100 Brea, California 92821 Fax: 714-671-5821 Multi-Spectral, Digital, Infrared Electro-Optical FSC Model No. s FS10-R and FS10-A Unitized,

More information

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS SXL Conventional Zone Fire Alarm Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS 4 Zones Expandable to 8 Zones Microprocessor Based Control Factory Programmed Field Configurable 2 Style Y Notification

More information

FireNET Plus Wiring Instructions

FireNET Plus Wiring Instructions FireNET Plus Wiring Instructions This manual provides wiring instructions for the 1 loop and 2 loop version of the FireNET Plus panels, which supports our finest Hochiki s DCP protocol. Note: Refer to

More information

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL SECTION 1 - GENERAL CONDITIONS I. SCOPE: This specification outlines the requirements for a Fike Micromist Water Mist Fire Suppression System with a Cheetah Xi 50 addressable detection and control system.

More information

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX Page 1 of 10 Model 10807800 January 2014 ACCURATE ELECTRONICS INC PO BOX 1654 97075-1654 8687 SW HALL BLVD 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 WWW.ACCURATE.ORG Practice Section 10807800

More information

ANNUNCIATOR FIXED MODULE

ANNUNCIATOR FIXED MODULE 12 Clintonville Road Northford, CT 06472 Phone: 203-484-7161 Fax: 203-484-7118 THE ANNUNCIATOR FIXED MODULE Installation Manual for the AFM-16ATF and AFM-32AF Annunciator Modules Document # 15970 3/27/95

More information

Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd. Web: ISO 9001:2015 certified

Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd.   Web:  ISO 9001:2015 certified Linear detection solution Product Brochure About Us Signaline is a comprehensive range of linear detection systems providing solutions for fire and water leak detection. Our linear detectors are 100% manufactured

More information

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional

More information

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description FIREFLEX VACTEC description This FIREFLEX VACTEC integrated fire protection system consists of a vacuum system trim totally pre-assembled, prewired and factory tested. All electrical and mechanical components

More information

AL600ULX Series. Power Supply/Charger. Installation Guide

AL600ULX Series. Power Supply/Charger. Installation Guide AL600ULX Series Power Supply/Charger Installation Guide Models Include: AL600ULX - Single Output AL600ULPD4 AL600ULPD4CB - Four (4) Fused Outputs - Four (4) PTC Outputs AL600ULPD8 AL600ULPD8CB - Eight

More information

The SharpEye 40/40I (IR3) Flame Detection

The SharpEye 40/40I (IR3) Flame Detection The SharpEye 40/40I (IR3) Flame Detection combine state-of-the-art technology with rugged durability and be ready to reliably work in any situation. Dräger offers a wide variety of high-quality flame-detectors

More information

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays AEGIS Conventional Fire Alarm-Suppression Control Unit FEATURES Agency Approvals FM Approved FM Approved to ANSI/UL 864, 9th edition FM Approved to ULC-S527-99 Other domestic U.S. approvals/listings pending/

More information

AL800ULADA. NAC Power Extender. Installation Guide

AL800ULADA. NAC Power Extender. Installation Guide AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery

More information

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels R 12 Clintonville Road, Northford, CT 06472 Phone: (203) 484-7161 FAX: (203) 484-7118 Instruction Manual for the MS-4012/4024 and CMS-4012/4024 Fire Alarm Control Panels Document 15586 5/11/93 Revision:

More information

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM User Instructions For The Model 5200 Gas Monitor System To completely customize the specifications to your exact application, modifications to the following

More information

ACCURATE ELECTRONICS INC

ACCURATE ELECTRONICS INC ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A

More information

SC-6 Six Supervised Control Module

SC-6 Six Supervised Control Module INSTALLATION AND MAINTENANCE INSTRUCTIONS SC-6 Six Supervised Control Module SPECIFICATIONS Normal Operating Voltage: Stand-By Current: Alarm Current: Temperature Range: Humidity: Dimensions: Accessories:

More information

OPERATION AND INSTALLATION MANUAL

OPERATION AND INSTALLATION MANUAL EX+Plus 2 ZONE, 1AREA EXTINGUISHANT CONTROL PANEL OPERATION AND INSTALLATION MANUAL INTRODUCTION The Premier EX Plus is a 2 zone, single area panel for controlling the release of extinguishing gases in

More information

Conventional Fire Detection

Conventional Fire Detection SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct

More information

Variable Frequency Drive SERIES MP800 VFD

Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controls and Accessories Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for

More information

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev Installation Guide for AL600ULM Multi-Output Access Control Power Supply Charger Rev. 091800 1 AL600ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL600ULM multi-output access control

More information

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels Installation and user manual for the FX range of fire panels 1, 2, 4 and 8 zone panels Contents Panel installation 3 Panel connections 3 Wiring connection drawings 4 Panel facilities 6 Installation check

More information

The SharpEye 40/40R (IR) Flame Detection

The SharpEye 40/40R (IR) Flame Detection The SharpEye 40/40R (IR) Flame Detection requires fire/flame detection as a life-saving necessity The best solutions must combine state-of-the-art technology with rugged durability and be ready to reliably

More information

SP40S-D. Kingfisher Company, inc. Features: Description:

SP40S-D. Kingfisher Company, inc. Features: Description: Kingfisher Company, inc. SP40S-D Features: Multi-use applications The system can function as an evacuation system, an emergency messaging system, and an employee notification system Fire code applications

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance

More information

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi 50 (P/N 10-071) is a state-of-the-art true intelligent digital peer-to-peer modular suppression control system.

More information

SEC 2000 Millenium Infrared Gas Detector

SEC 2000 Millenium Infrared Gas Detector SEC 2000 Millenium Infrared Gas Detector Instruction and Operation Manual Sensor Electronics Corporation 5500 Lincoln Drive Minneapolis, Minnesota 55436 USA (952) 938-9486 Fax (952) 938-9617 Email: sales@sensorelectronic.com

More information

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC. M Series Multi-Output Access Control Power Supply Charger Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 4 amp @ 12VDC or 3 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp @

More information

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger Installation Guide for AL400ULM Multi-Output Access Control Power Supply Charger R AL400ULM - Multi-Output Access Control Power Supply/Charger Rev. 072500 Overview: The AL400ULM multi-output access control

More information

Desigo Fire Safety Marine Fire and Detection Equipment Models FH-2071-UM, BP-62 and USCG-HPLATE

Desigo Fire Safety Marine Fire and Detection Equipment Models FH-2071-UM, BP-62 and USCG-HPLATE s Desigo Fire Safety Marine Fire and Detection Equipment s FH-2071-UM, BP-62 and USCG-HPLATE ARCHITECT AND ENGINEER SPECIFICATIONS Marine equipment is used with Desigo 252-point and 504-point addressable

More information