Declaration of conformity
|
|
- Peter Henderson
- 6 years ago
- Views:
Transcription
1 File: ATEX Manoswitch DoC Rev: id: mk Declaration of conformity The products listed in Appendix B, meet the requirements for a simple apparatus given by the standards listed below. As the product does not have an own potential source of ignition and therefore it is not subject to the ATEX directive. Declaration is only valid when installation is in accordance with Appendix A, page 2 of this document. For products listed in Appendix B as containing plastic, there is a risk of ignition by electrostatic discharge when rubbing the equipment, which cannot be avoided. To comply with ATEX these products must have a warning label Avoid electrostatic charging attached in an easy to read position. Product identification: All items listed in Appendix B. Description of product: Component for Fire Extinguishing System. Product specification: Devices in the category Simple apparatus Directives & Standards: ATEX 2014/34/EU (article 1, clause 1a) EN :2012 incl A11:2013, EN :2012, (clause 5.7 a). Limitations Ex-Classification: A certified intrinsic safety barrier (ISB) (Zener Diode Barrier or Galvanic Isolated Barrier) must be connected. Maximum values for the ISB: Uo = 28V Io = 93mA Po = 700mW Eg: Phoenix MACX MCR-Ex-SL-RPSSI-I or Pepperl+Fuchs Z728) Ex ib IIC T4 (-40Cº Ta +70Cº) Ci< 0.2nF, Li negligible =>0 Ui < 28V, Ii < 100mA, Pi<700mW. Production facility: Product marking: Fire Eater, Vølundsvej 17, 3400 Hillerød Fire Eater name or Logo, Product name, Serial number. Vølundsvej 17, 3400 Hillerød, Denmark Conformity mark: Certificates: None Notified body: CNPP 1116 BRE 0832 DNV GL 0575 UL EX15566 FM II 2G Ex ib IIC T4, Simple Apparatus Signed by Technology Manager Hillerød: 20 October 2017 Michael Kroneder (CTO) Fire Eater A/S Vølundsvej 17 DK-3400 Hillerød Tel.: VAT No.: info@fire-eater.com
2 File: ATEX Manoswitch DoC Version date: id: mk Appendix A, Ex Calculation Calculation of the circuitry for verification of Ex compliance of the system. The output parameters of the safety barrier (Ex) must be lower than the input parameters of the devices. Therefore, the following applies: Control Panel Non-Hazardous Area Intrinsic Safety Barrier Hazardous Area Uo Ui Io Ii Intristically Po Pi Safe Co Ci+Cc Device Lo Li+Lc Ui: Max. permissible voltage Uo: Max. open-circuit voltage [V] Ii: Max. permissible current Io: Max. short-circuit current [ma] Pi: Max. permissible power Po: Max. short-circuit power [mw] Ci: Internal capacitance Co: Max. permissible capacitance [nf] Li: Internal inductance Lo: Max. permissible inductance [mh] Cc: Cable capacitance Lc: Cable inductance n = Total number of devices l = Total cable length [m] Calculation example: 3 manoswitches in series, with a total cable length of 100 meters (0.1km) Safety barrier characteristics: (Zener barrier Pepperl+Fuchs Z978) Uo: 28 [V] Io: 47 [ma] Po: 320 [mw] Co: 83 [nf] Lo: 1.6 [mh] Manoswitch characteristics: Ui: 28 [V] Ii: 100 [ma] Pi: 700 [mw] Ci: 0.2 [nf] Li: ~ 0 [mh] Cable characteristics: (FE item ) Cc: 270 nf/km Lc 0.67 mh/km Calculation Uo Ui => [V] Meet the requirement Io Ii => [ma] Meet the requirement P0 Pi => [mw] Meet the requirement Co (n xci) + (l x Cc) => 83 [nf] (3x0.2) + (0.1 x 270) = 27.6 [nf] Meet the requirement Lo (n x Li) + (l x Lc) => 1.6 [mh] (3x0) + (0.1x0.67) = [mh] Meet the requirement Fire Eater A/S Vølundsvej 17 DK-3400 Hillerød Tel.: VAT No.: info@fire-eater.com
3 File: ATEX Manoswitch DoC Version date: id: mk Appendix B Product data: Product with metal body ManoSw 28.4MPa sp16.6 UL ManoSw 43.1MPa sp24.9 UL ManoSw bar sp50 EN ManoSw 250bar sp ManoSw 43.1MPa sp ManoSw bar sp 166 EN ManoSw bar sp 249 EN ManoSw 0-250bar sp 150 conn ManoSw 0-250bar sp 166 conn ManoSw 0-400bar sp 225 conn ManoSw 0-400bar sp 249 conn ManoSw 0-40MPa sp249 GOST-R Pressure Switch w. Manual Reset Including below variants: -8 Customer specified -23 EAC (former GOST) -31 IEC331 cable -44 AISI316 housing -131 CCCF dial Fire Eater A/S Vølundsvej 17 DK-3400 Hillerød Tel.: VAT No.: info@fire-eater.com
4 Fire Eater A/S Attn.: Mr. Michael Kroneder Vølundsvej Hillerød Denmark 2630 Taastrup Denmark Phone October 2017 ATEX Statement concerning Simple Apparatus" Product description The Manoswitch is in the principle constructed as a standard Mechanical manometer of the Bourdon tube type, which in addition is mounted with a build in electrical micro switch. The micro switch is operated directly by a mechanical operator arm welded to the Bourdon tube. Electrical components: The Manoswitch is mounted with one single electrical component which is a simple micro switch of the type Panasonic micro switch: AVT or AVT or AVT rated 0.1 A 250 V ac. Type variants: Product with metal body ManoSw 28.4MPa sp16.6 UL ManoSw 43.1MPa sp24.9 UL ManoSw bar sp50 EN ManoSw 250bar sp ManoSw 43.1MPa sp ManoSw bar sp 166 EN ManoSw bar sp 249 EN ManoSw 0-250bar sp 150 conn ManoSw 0-250bar sp 166 conn ManoSw 0-400bar sp 225 conn ManoSw 0-400bar sp 249 conn ManoSw 0-40MPa sp249 GOST-R Pressure Switch w. Manual Reset Including below variants: -8 Customer specified -23 EAC (former GOST) -31 IEC331 cable -44 AISI316 housing -131 CCCF dial
5 Scheduled Drawings The Manoswitch is specified by the drawings: Engineering data Sheet, 11 pages, Document: UL listed production 11, Manoswitch The Declaration of Conformity and Instructions are specified by document: ATEX Manoswitch DoC , Rev pages. Simple Apparatus Intrinsically safe electrical equipment for use in Flammable atmospheres (zone 0, 1 or 2) must fulfil the requirements of EN :2012 inkl. Amd. A11:2013 together with EN :2012. The following components are considered as simple apparatus in accordance with EN clause 5.7: passive components, for example switches, junction boxes, resistors and simple semiconductor devices. Installation of Manoswitch - Conditions The Manoswitch can only be used as Simple Apparatus when installed in a system where it is supplied from a certified Intrinsically Safe safety barrier module (e.g. a Zener barrier) mounted in the safe area. The Manoswitch must be installed in accordance with the installation instructions specified in the Declaration of Conformity : Appendix A, Ex-Calculation Entity parameters for Manoswitch Ui: 28 [V], Ii: 100 [ma], Pi: 700 [mw], Ci: 0.2 [nf], Li: ~ 0 [mh] The chosen barrier module must match these entity parameters. Marking of Simple Apparatus In accordance with EN :2014, Clause 16.4 (covering Installation of equipment for explosives atmospheres), Simple Apparatus must be clearly identifiable by durable marking. Labelling of simple apparatus may be done by e.g. the manufacturer of the equipment and should make it possible to clearly identify the equipment as Simple Apparatus and furthermore a reference to the correct installation may also be made. Page 2 of 3
6 Final ATEX Marking: II 2G Ex ib IIC T4 Simple Apparatus The Manoswitch is marked in the following way: Conclusions When the Manoswitch is installed in accordance with Fire Eater s Declaration of Conformity including the instructions in Appendix A, Ex-Calculation, the product can be considered as Simple apparatus in accordance with EN , Clause 5.7. Best regards, Jakob Nittegaard ATEX Senior Specialist Product Development Page 3 of 3
4) Intrinsic Safety Certification
INSTRUCTION MANUAL Minialert Intrinsically Safe Round Combined Unit Section Volume Control Tone Generator S2 S3 Tone Selection Switches Fig 1 Simplified block diagram The combined unit is CE marked for
More informationD SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410
FIELDBUS INTRINSICALLY SAFE CONCEPT (FISCO) APPROVAL FISCO allows interconnection of intrinsically safe apparatus to associated apparatus not specially examined in such combination. The criteria for interconnection
More informationINSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon
INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing
More informationRADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION
Special Safety Instruction en RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION Contents TankRadar Pro European ATEX Directive Information............................... 2 ATEX marking and Ex Certification
More informationIECEx Certificate of Conformity
Page 1 of 10 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate
More informationDocumentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16
safetec Documentation Explosion-Protection for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16 in Smoke Detection System SDS-48 according IEC 60079-25
More informationInductive slot sensor
0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
More informationFDOOT241-A9-Ex Multisensor fire detector
FDOOT241-A9-Ex Multisensor fire detector ASAtechnology TM For potentially explosive areas Sinteso Collective Signal processing with ASAtechnology Multiple protocol detector (collective/fdnet-ex) Event-controlled
More informationAir Sensor. SAC Ex FCS Ex. Manual ATEX. AQ M-Tech AB
Air Sensor SAC Ex FCS Ex Manual AQ M-Tech AB ATEX Air Sensor SAC Ex FCS Ex ATEX Certified AQ M-Tech AB Manual version 2.2 February 2017 2 Air Sensor Manual for SAC Ex and FCS Ex Table of contents 1. Manufacturer
More informationOOH740-A9-Ex Multisensor fire detector
OOH740-A9-Ex Multisensor fire detector ASAtechnology TM For potentially explosive areas Cerberus PRO Collective Signal processing with ASAtechnology Multiple protocol detector (collective/c-net-ex) Event-controlled
More informationINSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C
PSD1001C INSTRUCTION MANUAL SIL 3 SIL 2 IIB Group Power Supply for Hazardous Area Equipment DINRail Model PSD1001C PSD1001C SIL 3 SIL 2 IIB Group Power Supply for hazardous Area Equipment ISM006510 General
More informationSET-2000 Oil/Sludge 12 VDC
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 12.2.2015 Internet: www.labkotec.fi 1/14 SET-2000 Oil/Sludge 12 VDC Alarm Device for Oil Separators with
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm
More informationATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X
Installation Instructions P/N MMI-20010174, Rev. A June 2007 ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X For ATEX-approved sensor installations
More informationDB5 Intrinsically Safe Sounder Type DB-5
Operating Instructions RTK Instruments Limited DB5 Intrinsically Safe Sounder Type DB-5 Description The DB5 Sounder is a strong, lightweight warning sounder, CENELEC certified to Ex II 1G EExia IIC T4
More informationEU DECLARATION OF CONFORMITY
The Low Voltage Directive (LVD) 2014/35/EU and Electromagnetic Compatibility (EMC) Directive 2014/30/EU. Capacitive level sensor DLS 27N(T) Capacitive level sensor type DLS 27N(T) is designed to bistable
More informationE2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.
E2S Datasheet 1.2.1 v10a ISmA1 ISminialarm The ISmA1 is a compact, 100dB(A) alarm sounder. Approvals include ATEX, IECEx and GOSTR for Zone 0 applications and FM approval for Class I Division 1 and Class
More informationSBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)
SBEx-4 BISTATE SEPARATOR,, 3 or 4 channels in rail housing (TS3,,mm width) - group I category (M), group II and III category () accompanying device, - intrinsically safe input circuits with ia protection
More informationE2S Datasheet v10a
E2S Datasheet 1.2.3 v10a ISmC1 ISminialert The ISmC1 is a compact combined 100dB(A) alarm sounder and L.E.D. beacon only one Zener barrier or galvanic isolator required to run both sounder & beacon or
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 8 mm
0102 Model Number Features 8 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
More informationOOH740-A9-Ex Multi-sensor fire detector
OOH740-A9-Ex Multi-sensor fire detector ASAtechnology TM For potentially explosive areas Cerberus PRO Collective Signal processing with ASAtechnology Multiple protocol detector (collective/c-net-ex) Event-controlled
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...
More informationINSTRUCTION MANUAL (ATEX)
INSTRUCTION MANUAL (ATEX) ISmA1M Minialarm Intrinsically Safe Round ISmA1M Volume Control Tone Generator S3 Tone Selection Switches Fig 1 Simplified block diagram The ISmA1M sounder is CE marked for compliance
More informationSET Installation and Operating Instructions. Level switch for one sensor
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel.: +358 29 006 260 Fax: +358 29 006 1260 7.11.2013 Internet: www.labkotec.fi 1/14 SET-1000 Level switch for one sensor Copyright 2013 Labkotec Oy
More informationSafety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS
Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS 10.0008 Ex td A20, A20/21, A20/22, A21 IP66 T 0044 37675 Contents 1 Area of applicability 3 2 General information 3 2.1 Zone 20 instruments
More informationTechnical Data. Dimensions
0102 Model Number Features 5 mm flush Usable up to SIL2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching element
More informationOilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor
Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000
More informationYTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,
User s Manual YTA Series Temperature Transmitters [Style: S3] Manual Change No. 10-008 Please use the attached sheets in the following manuals when the product is with /KU2 option and EN60000 Series based
More informationRosemount 3490 Series 4 20 ma + HART Compatible Controller
00825-0200-4841, Rev AB Rosemount 3490 Series 4 20 ma + HART Compatible Controller Failure to follow safe installation guidelines could result in death or serious injury The Rosemount 3490 Series Control
More informationTechnical Data. Dimensions
0102 Model Number Features 8 mm non-flush Stainless steel housing Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 8 mm
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Accessories BF 12 Mounting flange, 12 mm Technical Data specifications Switching element function NAMUR, NO Rated operating distance s n 4 mm Installation non-flush
More informationSITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.
General information 1 Marking of the degree of protection 2 SITRANS T SITRANS T Explosion protected temperature sensor Operating Instructions Range of uses 3 Installation 4 Assembly and disassembly 5 Commissioning
More informationCertificate of Compliance
Certificate of Compliance Issued to: GE Intelligent Platforms 240 The Village Butterfield Business Park Bedfordshire, Luton LU2 8DL United Kingdom Attention: John Purdy The products listed below are eligible
More informationCertificate of Compliance
FF0002 Certificate of Compliance Certificate: 2792948 Issued to: Siemens Canada Limited 1954 Technology Drive Peterborough, ON K9J 7B1 Canada Attention: Mr. Lee Rogers The products listed below are eligible
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No. : Status: Date of Issue: Applicant:
More informationATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres
Quick Introduction to: DANISH TECHNOLOGICAL INSTITUTE The Danish Technological Institute is a self-owned and not-fprofit institution. We develop, apply and disseminate research- and technologically-based
More informationSafety instructions VEGAPULS 64
Safety instructions Intrinsic safety "i" 4 20 ma/hart - two-wire Document ID: 53001 Contents 1 Area of applicability... 3 2 Important specification in the type code... 3 3 Different ignition protection
More informationOperating Instructions Edition 02/2007
Operating Instructions Edition 02/2007 Temperature Transmitter 7NG3214 with PROFIBUS PA 7NG3215 with FOUNDATION Fieldbus sitrans Introduction 1 General safety notes 2 SITRANS T Temperature transmitter
More informationIntrinsically Safe Flame Detector Installation Guide
This document is IS Installation Guide/00/Issue 3 Intrinsically Safe Installation Guide General This Installation Guide gives information on the intrinsically safe (I.S.) version of the flame detectors
More informationEx Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors
Instructions manual Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors HB Products A/S Bøgekildevej 21 DK8361 Hasselager support@hbproducts.dk www.hbproducts.dk
More informationDSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor
Product ID Type # Product # Drawing # DSF 1210.00 SHV Ex-atex (2m) 374Z-05066 110428F1 DSF 1210.00 SHV Ex-atex (5m) 374Z-05176 110428F1 DSF 1210.00 SHV Ex-atex (10m) 374Z-05590 110428F1 DSF 1410.00 SHV
More informationAnnubar Flowmeter Series
Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA
More informationATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE
DANISH TECHNOLOGICAL INSTITUTE The Danish Technological Institute is a self-owned and not-f-profit institution. We develop, apply and disseminate research- and technologically-based knowledge f the Danish
More informationSafety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******
Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O****** CSA 14.2662675 Ex ia IIC T6 Ga, Gb 0044 Document ID: 48924 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical
More informationFieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward
Foundation Fieldbus End Users Council Australia Inc. 9 Corcoran St Duncraig, WA 6023 P.O.Box Z5546 Perth, WA 6831 AUSTRALIA ABN 60 120 236 370 Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and
More informationInstallation and Operating Instruction
Installation and Operating Instruction Automatic Fire Detectors Series 900 Ex (i) 9893 0.00 GB Technical changes reserved! 0 Installation and Operating Instruction Automatic Fire Detectors Series 900 Ex
More informationDSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor
DSF xx15.xx xhv Ex-Atex Product ID Type # Product # Drawing # DSF 1215.01 SHV Ex-atex (5m) 304Z-05197 113216 DSF 1415.01 AHV Ex-atex S148 304Z-05256 113351 DSF 1615.01 SHV Ex-atex (5m) 304Z-05196 113214
More informationWeighing whole with Dini Argeo indicator + Dini Argeo JBxxx Atex junction box + zener barriers + Dini Argeo Atex load receptor (s/n )
Weighing whole with Dini Argeo indicator + Dini Argeo JBxxx Atex junction box + zener barriers + Dini Argeo Atex load receptor (s/n 123456) Description of the system The system is made up of the following
More information5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration
Planning and configuration of the I.S. 1 system 5 ENGINEERING 5.1 Safety instructions for system configuration and explosion protection During engineering, comply with the guidelines set out in EN 60 079-14.
More informationPESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard
Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard Persons concerned: Experienced professional electricians as per EU Directive
More informationSET-2000 Hi Level/Oil
Labkotec Oy Labkotie 1 FI-36240 KANGASALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 13.03.2008 Internet: www.labkotec.fi Alarm Device for Oil Separators Copyright 2008 Labkotec Oy We reserve
More informationVERSAFLOW VORTEX Supplementary instructions
VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
0102 Model Number Features Direct mounting on standard actuators EC-Type Examination Certificate TÜV99 ATEX 1479X Accessories BT32 BT32XS BT32XAS BT33 BT34 V1-G-N4-5M-PUR Female cordset, M12, 4-pin, NAMUR,
More informationSET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions
SET-000 Oil/Sludge Alarm Device for Oil Separators Copyright 007 Labkotec Oy We reserve the right for changes without notice TABLE OF CONTENTS GENERAL... INSTALLATION... 4. SET-000 Oil/Sludge Control Unit...
More informationIntrinsically Safe Solutions
Intrinsically Safe Solutions INSTALLATION MANUAL 04/12/14 Rev D DOC-01-029 Documentation Feedback Your feedback helps us keep our documentation up to date and accurate. If you have any comments or suggestions
More informationBA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13
BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13 Certification information label Total display Rate display Rotating flow indicator Annunciators for optional
More informationIECEx Certificate of Conformity
Page 1 of 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:1 Status: Current Certificate
More informationTechnical Data. Dimensions
0102 Model Number Features 15 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 15 mm Installation non-flush Assured operating distance s a 0...
More informationUniversal Tank Alarm Type Installation, Operation & Maintenance
Universal Tank Alarm Type 14400 Installation, Operation & Maintenance Universal Tank Alarm Type 14400 Contents Declaration of Conformity 3 IMPORTANT 3 General Description 4 General Operation 4 Installation
More informationInstallationsmanual GWSL1100/2100, GWML3100
GRAIN-WATCH SYSTEM Installationsmanual Grain Watch Sensor Cables GWSL1100/2100, GWML3100 Table of contents 1 1 1 3. Safety certification and features 3.1. Certification label information 3.2. Safety approvals
More informationsrra, of Conformity IECEx Gert f cate ?-ot,b
ts of Conformity I NTERNATIONAL ELECTROTECHNICAL COMMISSION IEG Gertification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.recex com Certificate No. ' IECEx SIR
More informationUser s Manual. EJA Series Differential Pressure and Pressure Transmitters Installation Manual. 1. Introduction. 2. Handling Cautions. 3.
User s Manual EJA Series Differential Pressure and Pressure Transmitters Installation Manual 1. Introduction 1.1 For Safe Use of Product...2 1.2 Warranty...3 1.3 ATEX Documentation...4 2. Handling Cautions
More informationBA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13
TR Automatyka Sp. z o. o. Tel. (+48 022) 886 10 16 www.trautomatyka.pl ul. Lechicka 14 ; 02-156 Warszawa Fax. (+48 022) 846 50 37 biuro@trautomatyka.pl BA334D Intrinsically safe Externally powered pulse
More informationA Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document
A190325 Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document CONTENTS INTRODUCTION 1. DUAL CERTIFIED COMPONENTS 1.1 Simple Apparatus Switches For
More informationUser s Manual. EJA Series Differential Pressure and Pressure Transmitters Manual Change No Yokogawa Electric Corporation
User s Manual EJA Series Differential Pressure and Pressure Transmitters Manual Change No. 12-004 For the models EJA and EJA-A series with option code /KF21, /KU21, /KU22 or /KN26, please use this manual
More informationOilSET Installation and Operating Instructions. Oil Separator Alarm Device
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 18.11.2010 Internet: www.labkotec.fi 1/10 OilSET-1000 Oil Separator Alarm Device Copyright 2010 Labkotec
More informationFDCL221-Ex Line adapter (Ex)
FDCL221-Ex Line adapter (Ex) Addressed (FDnet-Ex/C-NET-Ex) For operating FDnet-Ex/C-NET-Ex peripheral devices in potentially explosive areas Sinteso Cerberus PRO Electrical isolation of Ex and non-ex lines
More informationOPTIBAR P 1010/2010 C Supplementary instructions
OPTIBAR P 1010/2010 C Supplementary instructions Pressure transmitter Equipment category II 1G / Ga, II 1D / Da in protection type intrinsic safety Exi KROHNE CONTENTS OPTIBAR P 1010/2010 C 1 Safety instructions
More informationINSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter DIN-Rail Power Bus and Termination Board Model D5264S D5264S
D5264S INSTRUCTION MANUAL SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter DIN-Rail Power Bus and Termination Board Model D5264S Characteristics General Description: The single channel DIN Rail
More informationAND INSTALLATION MANUAL
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel. +358 29 006 260 Fax +358 29 006 1260 Internet: www.labkotec.fi 10.10.2013 SET/DM3AL Level sensor OPERATION AND INSTALLATION MANUAL 1(5) SYMBOLS
More informationIntrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter
PD685 Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter Actual Size Digits C US Intrinsically Safe 3½ Digits LARGE DISPLAY NEMA 4, Type 4X, IP67 Loop-Powered Field-Mount Process Meter 4-20 ma
More informationPROTECT SRB 200EXi-1A
2 Installation up to zone 1/21 J S L1 0V X1 X3 S11 S12 S21 S22 Installation up to zone 2 A1 F1 F2 U B U EXi U i 0V S12 S22 X1 X3 K1 Logic K2 K1 K2 13 23 U EXi SRB 200EXi U B -1A U i K1 K2 PA PA A1 A2 13
More informationDUR 40Ex Intrinsically Safe SMOKE DETECTOR
DUR 40Ex Intrinsically Safe SMOKE DETECTOR Installation and Maintenance Manual IK E317 001GB IB Issue 2 IK E317 001GB The Universal Optical Smoke Detector DUR 40Ex covered by the present manual, complies
More informationPROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO
PROZESSAUTOMATION Manual SEGMENT PROTECTOR R-SP-!12 FieldConnex TM Segment Protectors with overloaod protection and short-circuit current limitation for the connection of 12 field devices Zone 1 Zone 2
More informationOilSET-1000 (12 VDC)
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 Internet: www.labkotec.fi 20.03.2009 1/11 OilSET-1000 (12 VDC) Oil Separator Alarm Device Copyright 2009
More informationLocal Control Panels for VG9000H LCP9H Series. Installation, Maintenance and Operating Instructions
Local Control Panels for VG9000H LCP9H Series Installation, Maintenance and Operating Instructions 7 LCP9H 70 en 9/2011 2 7 LCP9H 70 en Table of Contents 1 LCP9H Local Control Panels for VG9000H.. 3 1.1
More informationReport No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor
Report No. 3040249EC FM Approvals Ltd 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT Product: Model and/or Type Reference: Flame Detector IPES-IR3 Description of the Product:
More informationBattery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance
Battery Powered Separator Alarm Type 17200 Standalone Unit Installation, Operation & Maintenance Battery Powered Separator Alarm Type 17200 Contents Declaration of Conformity 3 IMPORTANT 3 General Description
More informationPumpSaver ISS-105 IS Super Cell Installation Guide
PumpSaver ISS-105 IS Super Cell Installation Guide Visit our website at www.symcom.com for our complete catalog and new product listings! 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848
More information国家级仪器仪表防爆安全监督检验站 National Supervision and Inspection Centre for Explosion Protection and Safety of Instrumentation (GYJ ) (Attachment Ⅰ) Attachm
国家级仪器仪表防爆安全监督检验站 National Supervision and Inspection Centre for Explosion Protection and Safety of Instrumentation (GYJ14.1317) (Attachment Ⅰ) Attachment Ⅰ (Translation) Isolated safety barrier type KFa
More informationCertificate of Compliance
FF0002 Certificate of Compliance Certificate: 70009779 Issued to: Pepperl+Fuchs GmbH Lilienthalstrasse 200 Mannheim, 68307 GERMANY Attention: Martin Holdefer The products listed below are eligible to bear
More informationBA488CF Intrinsically safe Panel mounting Fieldbus Display
BA488CF Intrinsically safe Panel mounting Fieldbus Display Issue: 8 Issue: 8 8 th May 2006 2 CONTENTS 1. Description 1.1 Documentation 1.2 Version 2.0 firmware 2. Operation 2.1 Controls 3. Intrinsic Safety
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-nA Edition 08/207 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4
More informationOPTIBAR DP 7060 Supplementary Instructions
OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,
More informationSensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0
Sensor module Operating instructions Sensor module, Document No. 11-51P2-7D0001 Version: 17 May 2011/Rev. 0 Operating Instructions Sensor-Module Type: 17-51P2-. Document no.: 11-51P2-7D0001 Version: 17.
More informationSupplementary Installation and Operating Instructions. Category II2G
Supplementary Installation and Operating Instructions Flap-type Flow Meter Category II2G 2 Contents 1. General safety directions...3 2. Main safety-relevant characteristics...4 2.1. Category / Zone...4
More informationUser s Manual YTA610 and YTA710 NEPSI Certification
User s Manual YTA60 and YTA70 NEPSI Certification [Option code: /NS, /NS5 and /NF] st Edition . INTRODUCTION Thank you for purchasing the YTA60 and YTA70 Temperature transmitters. This manual contains
More informationFAHM Co. Temperature Transmitter PTT74 Series
FAHM Co. PTT74 Series The PTT74 is a versatile temperature transmitter that delivers field reliability and advanced accuracy and stability to meet demanding process needs. PTT74 Family of Transmitters
More informationRTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ
Operating Instructions RTK Instruments Limited Telephone: 44 (0)1423 580500 Facsimile: 44 (0)1423 580501 DA135 Intrinsically Safe LED Beacon Introduction This manual provides the information necessary
More informationPEPPERL+FUCHS GmbH
Comfort series 1.5 mm embeddable M8x1 4 25 16 13 LED Switching element function NAMUR NC Rated operating distance s n 1,5 mm Installation embeddable Assured operating distance s a 0... 1,215 mm Reduction
More informationSingle pressure controls for Refrigeration, Air-conditioning and Heatpump applications
Series P77 Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications Product bulletin These pressure controls are designed for use in a variety of applications involving refrigeration
More informationOMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments
OMC-158-2 Ex interface unit Manual Version 1.2 August 2017 Author: Observator Instruments Revisions: 0.1 (October 2016) First issue 0.2 (December 2016) Prototype 0.3 (January 2017) Test release 1.0 (March
More informationAM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74
AM54 Instruction Bulletin North American Installation Addendum Document Number PN25016 Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74
More informationLocal Control Panels for VG9000H LCP9H Series. Installation, Maintenance and Operating Instructions
Local Control Panels for VG9000H LCP9H Series Installation, Maintenance and Operating Instructions 7 LCP9H 70 en 2/2017 2 7 LCP9H 70 en Table of Contents 1 LCP9H Local Control Panels for VG9000H...3 1.1
More informationMark* VIe and Mark VIeS Control Systems Equipment in Hazardous Locations (HazLoc) Instruction Guide
GEH-6725J Mark* VIe and Mark VIeS Control Systems Equipment in Hazardous Locations (HazLoc) Instruction Guide Apr 2017 These instructions do not purport to cover all details or variations in equipment,
More informationInstrumentation Products and Applications
1 1/0 Instrumentation Products and Applications 1 Instrumentation Safety barriers I.S. Isolators - DIN rail mounting - Eurocards - Modules Remote I/O Operating and monitoring systems Instrumentation systems
More informationTank Gauging System Special Safety Instruction
Tank Gauging System www.rosemount-tg.com Rosemount TankRadar REX Table of Contents Contents SPECIAL SAFETY INSTRUCTION........................ 1-1 1. GENERAL REQUIREMENTS....................... 1-2 1.1
More informationFire Alarm System Accessories
Approved by APPROVED Fire Alarm System Accessories FM Approved* Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer
More information