1 Metasys Connectivity Technical Manual 69. Metasys Integrator Section Application Note Issue Date 0900 APPLICATION NOTE Metasys Integrator Cleaver-Brooks Application lntroduction Page Application Details * Component Requirements *8 Vendor Contact Information 9 Design Considerations *0 Cable Connections Cable Pinouts Connecting the Cable Metasys Integrator Setup * Point Mapping Tables Boiler Control Panel Points - ASCII Interface 6 Boiler Control Panel Points - CB-GPI *7 Enhancer Boiler Points - for ASCII Interface or CB-GPI 9 Enhancer General Points - ASCII Interface or CB-GPI 0 CB-780 Controller Points CB-78 Expanded Annunciator Points Metasys Network Setup Mapping to a CS Object * Custom Integration * *Indicates those sections where changes have occurred since the last printing. 000 Johnson Controls, Inc. Code No. LIT-690
2 Metasys Integrator Metasys Integrator Cleaver-Brooks Application
3 lntroduction This document explains the Metasys Integrator Cleaver-Brooks application. Use this document with the Metasys Integrator technical bulletins in the Metasys Connectivity Technical Manual (FAN 69.) which provide information on installing and commissioning the Metasys Integrator unit. For information on Cleaver-Brooks boiler control panels, see Cleaver-Brooks documentation (obtainable from a Cleaver-Brooks representative). Note: If you are using a Universal Packaging Module (UPM), you must install the Metasys Integrator 00 Series in a two high enclosure (EN-EWC-0) rather than a one high enclosure (EN-EWC-0) as shown in the figures in this application note. Application Details ASCII Interface The Metasys Integrator unit allows Cleaver-Brooks equipment to become an integral part of the Metasys and Metasys Companion Networks. Once either a ASCII Interface or CB-General Purpose Interface (CB-GPI) and boiler control panels are connected to a Metasys or Companion Network via the Metasys Integrator unit, their data is available to the full complement of Metasys Building Automation System (BAS) features, including Change-of-State (COS) monitoring, alarm notification, trend, and totalization. The ASCII Interface allows information to be transmitted between boiler control panels and non-cleaver-brooks devices (such as the Metasys Integrator unit). A six slot CB-Link is required between the ASCII Interface and the boiler control panels. Optionally, you can connect a Enhancer to Slot 6. However, if you use a Enhancer, you must tie it into Slot 6, and you must then tie the ASCII Interface into Slot as shown in Figures and. Each Metasys Integrator vendor port can connect to one ASCII Interface. Each CB-Link can connect to five boiler control panels, or four boiler control panels and one Enhancer. Figure shows a Metasys Network with the Metasys Integrator unit connected to one ASCII Interface. Four boiler control panels connect to the ASCII Interface through Slots through on the CB-Link. A Enhancer connects to Slot 6 on the CB-Link. Figure shows a similar Cleaver-Brooks configuration integrated into a Metasys Companion Network. Metasys Integrator Metasys Integrator Cleaver-Brooks Application
4 ump Note: For a single boiler, the ASCII interface can connect directly to the boiler control panel without a CB-Link. See your Cleaver-Brooks representative. N LAN Standard Network Control Unit (NCU) RS-8 RS- ASCII Interface 6 CB-Link Metasys Integrator Unitary (UNT) Controller N Bus Boiler Control Panel () Boiler Control Panel () Boiler Control Panel () Boiler Control Panel () Enhancer Intcb Note: If you are using a UPM, you must install the Metasys Integrator 00 Series in a two high enclosure (EN-EWC-0) rather than a one high enclosure (EN-EWC-0) as shown in the figures in this application note. Figure : Cleaver-Brooks Boiler Control Panels and Metasys Integration ( ASCII Interface) Metasys Integrator Metasys Integrator Cleaver-Brooks Application
5 Panel Unit Workstation RS-8 CB-Link RS- ASCII Interface 6 Metasys Integrator UNT N Bus Boiler Control Panel () Boiler Control Panel () Boiler Control Panel () Boiler Control Panel () Enhancer Cbcomp Note: If you are using a UPM, you must install the Metasys Integrator 00 Series in a two high enclosure (EN-EWC-0) rather than a one high enclosure (EN-EWC-0) as shown in the figures in this application note. Figure : Cleaver-Brooks Boiler Control Panel and Metasys Companion Integration ( ASCII Interface) CB-GPI You can also integrate Cleaver-Brooks equipment with the Metasys and Metasys Companion Networks through the CB-GPI. This interface resides on an RS-8 bus. The CB-Link communicates with up to five /CB-780 boiler controls and, optionally, a Enhancer. The RS-8 connects to a Johnson Controls RS- to RS-8 converter (MM-CVT0) which connects via an RS- cable to the Metasys Integrator panel. The Metasys Integrator unit can receive data from, and send data and commands to, Cleaver-Brooks equipment. Each Metasys Integrator vendor port can connect to one RS- to RS-8 converter which can connect by RS-8 bus to one CB-Link. Install the CB-GPI in Slot 6 of the CB-Link, unless a Enhancer is present. If a Enhancer is present, you must install it in Slot 6, and you must install the CB-GPI card in Slot. The number of boiler controllers that you may connect is then reduced to four. Metasys Integrator Metasys Integrator Cleaver-Brooks Application
6 Figure shows a CB-Link Communication Interface with burner/boiler control equipment integrated into the Metasys Network. N LAN MM-CVT0 Converter RS-8 Standard NCU RS- CB-Link 6* Metasys Integrator Boiler Control Panel CB-780 UNT N Bus *Slot 6 on the CB-Link Communications Interface must contain a CB-GPI card unless a Enhancer option is present. intcbgpi Figure : Cleaver-Brooks Boiler Control and Metasys Integration (GPI Version) 6 Metasys Integrator Metasys Integrator Cleaver-Brooks Application
7 Figure shows a CB-Link with burner/boiler control equipment integrated into the Metasys Companion Network. Panel Unit Workstation RS- MM-CVT0 Converter CB-Link 6* UNT Metasys Integrator RS-8 ** ** Boiler Control Panel N Bus *Slot 6 on the CB-Link Communications Interface must contain a CB-GPI card unless a Enhancer option is present. **End-of-Line (EOL) Resistor Required Enhancer Cbgpcomp Figure : Cleaver-Brooks CB-GPI and Metasys Companion Integration Metasys Integrator Metasys Integrator Cleaver-Brooks Application 7
8 Component Requirements ASCII Interface CB-GPI The following lists describe the components that are needed to integrate Cleaver-Brooks equipment through the ASCII Interface or through the CB-GPI:! Properly installed ASCII Interface, CB-Link, and boiler control panels! RS- cable (for connecting the ASCII Interface to the Metasys Integrator unit)! Metasys Integrator unit! N Bus (for connecting the Metasys Integrator unit to the Metasys or Companion Network)! Portable Personal Computer (PC) for downloading vendor communication tables (.VCT files) and network setup information into the Metasys Integrator unit, and for running diagnostics! Cable for connecting portable PC to the Metasys Integrator unit! The correct vendor communication table (.VCT file) to download into the Metasys Integrator unit (supplied on Metasys Integrator Tables and Models CD-ROM)! Properly installed CB-Link with a CB-GPI card installed in Slot 6 (unless you are using a Enhancer option) and Cleaver-Brooks equipment.(a Cleaver-Brooks representative is responsible for installing all Cleaver-Brooks equipment.)! If a Enhancer is present, you must install it in the sixth slot, and you must install the CB-GPI card in the fifth slot.! Johnson Controls RS- to RS-8 converter (MM-CVT0).! RS- cable (for connecting the MM-CVT0 to the Metasys Integrator unit).! RS-8 cable (for connecting the MM-CVT0 to the CB-GPI).! Metasys Integrator unit.! N Bus (for connecting the Metasys Integrator unit to the Metasys or Companion Network).! Portable PC for downloading vendor communication tables (.VCT files) and network setup information into the Metasys Integrator unit, and for running diagnostics.! Cable for connecting portable PC to the Metasys Integrator unit.! The correct vendor communication table (.VCT file) to download into Metasys Integrator (supplied on Metasys Integrator Tables and Models CD-ROM).! Enhancer Version 7. or higher. 8 Metasys Integrator Metasys Integrator Cleaver-Brooks Application
9 This document describes the RS- cable and the vendor communication tables. Cleaver-Brooks documentation describes their equipment. The remaining components are described in the Metasys Integrator technical bulletins. Metasys Release Requirements Metasys Companion Release Requirements Vendor Component Requirements Vendor Contact Information To integrate Cleaver-Brooks equipment into the Metasys Network, you will need:! Metasys Operator Workstation (OWS) software Release 6.0 or higher! Metasys Integrator software/firmware Release 7.0 or higher To integrate Cleaver-Brooks equipment into the Metasys Companion Network, you will need:! Metasys Companion Release.0 or higher! Metasys Integrator software/firmware Release 7.0 or higher Integration between the Metasys Integrator unit and Cleaver-Brooks has been tested with the ASCII Interface Version.0 Rev. C. Integration of Cleaver-Brooks products not discussed in this document will require additional software development and testing by Systems Products. For information on integrating other products, refer to the Custom Integration section in this document. Please contact the Service Group at your local Cleaver-Brooks office. Call Cleaver-Brooks at () for assistance in determining how to contact your local Cleaver-Brooks office. Metasys Integrator Metasys Integrator Cleaver-Brooks Application 9
10 Design Considerations When integrating Cleaver-Brooks equipment, keep the following considerations in mind: Make sure all Cleaver-Brooks equipment is set up and running properly before attempting to integrate with the Metasys or Companion Network. (The Cleaver-Brooks representative is responsible for operation of CB equipment.) RS- cable distance between the Metasys Integrator unit and the ASCII Interface or the Johnson Controls MM-CVT0 is a maximum of 0 feet. Cable distance between the CB-GPI and MM-CVT0 can be a maximum of 000 feet. The CB-780 Burner Control and the CB-78 Expanded Annunciator for a given burner must be commissioned to the same slot (they must have the same vendor address). When using the CB-GPI with a, configure the as Setback Capable = Yes. When using the CB-GPI with an Enhancer, follow these instructions:. Disconnect the Metasys Integrator unit.. Connect the 9-pin female connector to a PC Commissioning port using the RS-8 CVT-0 cable configured for a Metasys Integrator unit.. Configure a terminal emulator for 9600 baud, 8 bit, stop bit, no parity.. Enter this command in lower case to set the GPI to its default values: sz zap. Enter this command in lower case to set the reply timeout to 8 seconds: st 8 Make sure you select the Enter key after each command. 0 Metasys Integrator Metasys Integrator Cleaver-Brooks Application
11 Cable Connections Cable Pinouts Use the following cable pinouts (Figure ) for the RS- connection between the Metasys Integrator unit and the ASCII Interface. (On standard NEMA Version, make connections to terminal block inside panel.) Vendor Port A or B of Integrator DB-9 Female ASCII Interface DB-9 Female Signal Pin Pin Signal TD RD GND RS- (0 ft maximum) RD TD GND intcb Figure : Cable Pinouts for ASCII Interface Use the following cable pinouts (Figure 6) for the RS- connection between the Metasys Integrator unit and the Johnson Controls MM-CVT0 RS- to RS-8 converter for use with the CB-GPI. Vendor Port A or B on Integrator DB-9 Female RS- Connector on MM-CVT0 DB- Male Signal Pin Pin Signal RD TD GND RTS 7 RS- (0 ft maximum) 7 RD TD GND RTS intcbgp Figure 6: Cable Pinouts to MM-CVT0 Converter for CB-GPI Metasys Integrator Metasys Integrator Cleaver-Brooks Application
12 Use Figure 7 for the RS-8 bus wires connection between the RS-8 side of the Johnson Controls MM-CVT0 RS- to RS-8 converter and the CB-GPI. MM-CVT0 N+ N- REF RS-8 CB-GPI RS-8 + RS-8 - REF a b c intcb8 Figure 7: RS-8 Bus Wire Connection for CB-GPI Connecting the Cable Connect the female end of the RS- cable to either Vendor Port A or Vendor Port B on the Metasys Integrator unit. Connect the other end to the DB-9 on the ASCII Interface. (Standard NEMA Version has a terminal block instead of a connector.) Metasys Integrator ASCII Interface Vendor Port A or B RS- Cable DB-9 intcb Figure 8: Port to Port Connection Metasys Integrator Metasys Integrator Cleaver-Brooks Application
13 Metasys Integrator Setup To set up the Metasys Integrator unit, use a portable PC connected to the Metasys Integrator Terminal Port. The Metasys Integrator unit setup involves: downloading the correct vendor communication table (.VCT file) setting up the port setting up the network addressing The following table provides information specific to the Cleaver-Brooks application. For detailed procedures, see the Metasys Integrator technical bulletins. If your system has a Enhancer option, you need to download the.vct files required for the Boiler points, Enhancer Boiler points, and the Enhancer general points. If you are not using a Enhancer, you need only the points. Metasys Integrator Metasys Integrator Cleaver-Brooks Application
14 Table : Metasys Integrator Setup for Cleaver-Brooks Vendor Communication Table (.VCT FILE) Port Setup ASCII CB-GPI Interface Boiler Points CB_HAWK.VCT CB_HAWKG.VCT Enhancer Boiler Points Enhancer General Points CB-780 Burner Controller Points CB-78 Expanded Annunciator Points Network Setup CB_NHBP.VCT CB_NHGP.VCT Not Available Not Available Baud Rate Word Length 8 8 Stop Bits Parity Even None Interface RS- RS-8 Vendor Address For Boiler Points: For Enhancer Boiler Points: For Enhancer General Points: CB-780 CB-78 to E to E 0 Not Available Not Available CB_NHBPG.VCT CB_NHGPG.VCT HW_RM78X.VCT HW_S780.VCT tgt, ss tgt, ss, blr tgt, ss tgt, ss tgt, ss Timeout Value With Enhancer Without Enhancer 000 ms ms 6000 ms Poll Delay ms 0 ms Performance Guide Approximate Scan Time (For a single N address) Boiler Points Enhancer Boiler Points Enhancer General Points CB-780 Series Burner Controller Points CB-78 Expanded Annunciator Points seconds 0 seconds 0 seconds Not Available Not Available 9 seconds 6 seconds 6 seconds seconds seconds Where tgt = CB-GPI card address (default 0) and ss = CB-Link slot number (-6) Where tgt = CB-GPI card address (default 0), ss = CB-Link slot number (6) and blr = boiler number (-) Metasys Integrator Metasys Integrator Cleaver-Brooks Application
15 Point Mapping Tables The following tables show the boiler control points. The points available for mapping depend on the type of equipment you are using. If you use only boiler control panels with an ASCII interface, use Table. If you also have a Enhancer, use the points shown in Tables,, and. The Enhancer points have been split into two groups: Enhancer Boiler Points (Table ) and Enhancer General Points (Table ). Metasys Integrator Metasys Integrator Cleaver-Brooks Application
16 Boiler Control Panel Points - ASCII Interface To get the hardware reference for mapping points to a Control System (CS) object (via the software model), combine the NPT (Network Point Type) and NPA (Network Point Address). For example, the hardware reference for the Gas Pressure point is. The hardware reference for the Pilot Valve point is 8. The points (internal parameters) cannot be mapped to standard objects. To monitor these points, map them to CS object AD attributes (which can then be mapped to standard objects). Table : Boiler Control Panel Points - ASCII Interface NPT NPA Unit Description psi psi psi % Operating Pressure (Steam Boiler) Operating Temperature (Hot Water Boiler) Gas Pressure Oil Pressure Oil Temperature Fire Rate Fire Rate Mode 0-auto, -manual Atomizing Air Proving Switch 0-off, -on Assured Low-Fire Cutoff 0-off, -on Demand Terminal 0-off, -on Recycle Limits 0-off, -on Pre-Ignition Interlock 0-off, -on Lock Out Interlock 0-off, -on Pilot Valve 0-off, -on Gas Main Valve 0-off, -on Oil Main Valve 0-off, -on Operating Setpoint (psi) (0-70) Operating Boiler Off Control Setpoint (psi) (0-70) Operating Boiler On Control Setpoint (psi) (0-70) Set Back Setpoint (psi) (0-70) Set Back Boiler Off Control Setpoint (psi) (0-70) Set Back Boiler On Control Setpoint (psi) (0-70) BO Set Back Mode 0-no, -yes # # # hour # hour % # # Network Point Type Network Point Address Fuel Selection (None, Gas, LtOil, HyOil, ChangOvr) Boiler Medium (None, Steam, Hot Water) Burner Status Burner Status Extended Total Cycles Total Runtime History - Burner Status History - Burner Status Extended History - Fault Code History - Fault Cycle History - Fault Hours History - Fire Rate History - Fuel Selection History - Sequence Timer 6 Metasys Integrator Metasys Integrator Cleaver-Brooks Application
17 Boiler Control Panel Points - CB-GPI To get the hardware reference for mapping points to a CS object (via the software model), combine the NPT (Network Point Type) and NPA (Network Point Address). For example, the hardware reference for the Gas Pressure point is. Table : Boiler Control Panel Points - CB-GPI NPT NPA Unit Description psi psi psi % hp Volt Operating Pressure (Steam Boiler Only) Operating Temperature (Hot Water Boiler Only) Gas Pressure (Gas Fuel Only) Oil Pressure (Oil Fuel Only) Oil Temperature (Oil Fuel Only) Fire Rate Boiler Size Flame Signal Gas Fuel Select 0-Off, -On Light Oil Fuel Select 0-Off, -On Heavy Oil Fuel Select 0-Off, -On Pre-Ignition Interlock 0-Off, -On Recycle Limits 0-Off, -On Lock Our Interlock 0-Off, -On Pilot Valve 0-Off, -On Gas Main Valve 0-Off, -On Oil Main Valve 0-Off, -On Atomizing Air Proving Switch 0-Off, -On Burner Switch (Demand) 0-Off, -On Assured Low Fire Cutoff 0-Off, -On Fire Rate Mode 0-Auto, -Manual Keyboard Mode 0-Program, -Operate Operating Setpoint (psi) (0-70) Operating Boiler Off Control Setpoint (psi) (0-70) Operating Boiler On Control Setpoint (psi) (0-70) Set Back Setpoint (psi) (0-70) Set Back Boiler Off Control Setpoint (psi) (0-70) Set Back Boiler On Control Setpoint (psi) (0-70) BO Set Back Mode 0-No, -Yes Boiler Medium (None, Steam, Hot Water) Boiler Type (None, Firetube, Watertube) Fuel Selection Fuel Series Flame Amplifier Part No. 8 - (, 0, 6) Rate Linearization Control Source (Auto, Manual, Remote) Set Back Capable (None, No, Yes) Program Identifier Network Point Type Network Point Address For more information, see Cleaver-Brooks documentation. Only the points that are applicable to the boiler configuration will be reliable. Continued on next page... Metasys Integrator Metasys Integrator Cleaver-Brooks Application 7
18 NPT (Cont.) NPA Unit Description # % % sec sec sec # hour # hour % sec Response Factor Low Fire Rate Max Fire Rate Prepurge Extend Post purge Extend Sequence Timer Burner Status Burner Status Extended Total Cycles Total Runtime History - Burner Status History - Burner Status Extended History - Fault Code History - Fault Cycle History - Fault Hours History - Fault Message History - Fire Rate History - Fuel Selection History - Sequence Timer Network Point Type Network Point Address For more information, see Cleaver-Brooks documentation. 8 Metasys Integrator Metasys Integrator Cleaver-Brooks Application
19 Enhancer Boiler Points - for ASCII Interface or CB-GPI To get the hardware reference for mapping points to a CS object (via the software model), combine the NPT (Network Point Type) and NPA (Network Point Address). For example, the hardware reference for the Total Fuel Used point is 9. Table : Enhancer Boiler Points - ASCII Interface or CB-GPI NPT NPA Unit Description % % % % MBTU MBTU $ Gal (or Therms) % % See Note. Stack Temperature Instant Efficiency Average Efficiency ( hour) Average Efficiency (8 hour) Average Efficiency ( hour) Total BTU Input Total BTU Output Average Cost of Output Total Fuel Used Oxygen Carbon Monoxide Opacity Fuel Flow Water/Steam Flow Nitrogen Oxides Auxiliary Input Auxiliary Input Network Point Type Network Point Address User-defined units. For more information, see Cleaver-Brooks documentation. The following notes refer to optional features for Enhancers. These points are valid only with a Enhancer with the feature listed. Efficiency Auxiliary Input Metasys Integrator Metasys Integrator Cleaver-Brooks Application 9
20 Enhancer General Points ASCII Interface or CB-GPI To get the hardware reference for mapping points to a CS object (via the software model), combine the NPT (Network Point Type) and NPA (Network Point Address). For example, the hardware reference for the Ambient Temperature point is. Table : Enhancer General Points - ASCII Interface or CB-GPI NPT NPA Unit Description psi (or psi) Header Pressure (Steam Boiler) Header Temperature (Hot Water Boiler) Ambient Temperature Outdoor Temperature Outdoor Reset Actual Setpoint (or psi) (or psi) System Setpoint (psi) (0-70) (or psi) System On Point (psi) (0-70) (or psi) System Off Point (psi) (0-70) (or psi) Setback Setpoint (psi) (0-70) (or psi) Setback On Point (psi) (0-70) 6 (or psi) Setback Off Point (psi) (0-70) # # # # # $ Lead Boiler # (0-) st Lag Boiler # (0-) nd Lag Boiler # (0-) rd Lag Boiler # (0-) th Lag Boiler # (0-) Cost of Gas ( ) $ Cost of Light Oil ( ) $ Cost of Heavy Oil ( ) Set Back Status 0-No, -Yes BO Reset Fuel Totals 0-Reset -Reset ADF ADF ADF ADF ADF % sec % sec Lag On Trigger Point Lag On Time Delay Lag Off Trigger Point Lag Off Time Delay Reset Ratio Network Point Type Network Point Address The following three notes refer to optional features for Enhancers. These points are only valid with a Enhancer with the feature described. Lead Lag Efficiency Outdoor Reset 0 Metasys Integrator Metasys Integrator Cleaver-Brooks Application
21 CB-780 Controller Points To get the hardware reference for mapping points to CS object attributes (via the software model), combine the NPT (Network Point Type) and NPA (Network Point Address). For example, the hardware reference for Test/Run Switch is. points (internal parameters) cannot be mapped to standard objects. To monitor these points, map them to CS object AD attributes (which can then be mapped to standard objects). Table 6: CB-780 Controller Points NPT NPA Unit Description Volt Flame Signal Sec Sec Sec Test/Run Switch 0-run, -test Operating Control T6 0-off, -on Interlock T7 0-off, -on Pilot Valve T8 0-off, -on Main Valve T9 0-off, -on Ignition T0 0-off, -on Pilot Valve Hold T6 0-off, -on Manual Open Switch T7 0-off, -on Low Fire Switch T8 0-off, -on High Fire Switch T9 0-off, -on Pre-Ignition Switch T0 0-off, -on Valve /Start T 0-off, -on Sequence Status Sequence Extension Sequence Timer Remote Command Burner Availability Amplifier Type Flame Response sec, -.0 sec Purge Time History -- Fault Code History -- Fault Message History -- Sequence Status History -- Sequence Extension History -- Sequence Timer Network Point Type Network Point Address For more information, see Cleaver-Brooks documentation. Metasys Integrator Metasys Integrator Cleaver-Brooks Application
22 CB-78 Expanded Annunciator Points To get the hardware reference for mapping points to CS object attributes (via the software model), combine the NPT (Network Point Type) and NPA (Network Point Address). For example, the hardware reference for Valve Closure is. points (internal parameters) cannot be mapped to standard objects. To monitor these points, map them to CS object AD attributes (which can then be mapped to standard objects). Table 7: CB-78 Expanded Annunciator Points NPT NPA Unit Description Valve Closure T 0-off, -on Burner Switch T 0-off, -on Operating Control T6 0-off, -on Auxiliary Limit T7 0-off, -on Auxiliary Limit T8 0-off, -on Low Water Cut Out T9 0-off, -on High Limit T0 0-off, -on Auxiliary Limit T 0-off, -on Oil Select T 0-off, -on Hi Oil Pressure T 0-off, -on Lo Oil Pressure T 0-off, -on Hi Oil Temperature T 0-off, -on Lo Oil Temperature T6 0-off, -on Atomizing Switch T9 0-off, -on Gas Select T7 0-off, -on Hi Gas Pressure T8 0-off, -on Lo Gas Pressure T9 0-off, -on Airflow Switch T0 0-off, -on Auxiliary Interlock T 0-off, -on Auxiliary Interlock T 0-off, -on Current Status Fault First Out Fault Valve Closure (unknown, off, on) Network Point Type Network Point Address For more information, see Cleaver-Brooks documentation. Metasys Integrator Metasys Integrator Cleaver-Brooks Application
23 Metasys Network Setup Metasys Network Setup is described in the Metasys Integrator technical bulletins. This section contains details specific to Cleaver-Brooks applications. Mapping to a CS Object Table 8 lists the software model files and the recommended Display and Network Terminal (NT) Command Attributes. Whether all the models shown in the table are needed depends on the equipment used. For example, if the system has only boiler control panels (and no Enhancer), only the model file for boiler control points is needed. If the system has a Enhancer and an ASCII interface, all the three ASCII model files are used. The Enhancer points are split into two groups: Enhancer boiler points and Enhancer general points The point mapping tables show how the points are categorized. Table 8: Software Model and CS Object Details Application Boiler Control Points - ASCII Enhancer Boiler Points - ASCII or GPI Enhancer General Points - ASCII or CB-GPI Boiler Control Points - GPI Software Model (on Tables and Models CD-ROM) CB_HAWK.DDL Display Attribute (recommended) (steam) or (hot water) CB_NHBP.DDL CB_NHGP.DDL CB_HAWKG.DDL (steam) or (hot water) (steam) or (hot water) CB-780 HW_RM78X.DDL Flame Signal CB-78 HW_S780.DDL Burner Switch NT Command Attribute (recommended) BO BO BO Whether you use the or point depends on whether your system has a steam boiler or a hot water boiler. For the NT Command attribute, use the same attribute as the Display attribute. However, since the CB-780 and CB-78 points are not commandable, you will not be able to command the attribute. (This must be defined, because the NT Command attribute cannot be null.) Metasys Integrator Metasys Integrator Cleaver-Brooks Application
24 Metasys Integrator Metasys Integrator Cleaver-Brooks Application
25 Custom Integration For information on integrating products which are not discussed in this document, first refer to the Metasys Compatible Global Catalog, an online list of released Connectivity products. If this list does not provide the information you require, consider using the System Integration Project Data Sheet to request a custom contract from the System Integration Team. Both the Metasys Compatible Global Catalog and the System Integration Project Data Sheet are accessible from The Advisor by performing the following steps:. Click on the Systems Products button located on the left side of The Advisor home page.. Click on the Product Literature link.. Click on the Manuals-FANS link.. Click on the 69.0 Metasys Connectivity Sales Resource Manual link.. Find the System Integration Project Data Sheet link in the table of contents. Click on this link to view an online copy of the System Integration Project Data Sheet or click on the Metasys Compatible Global Catalog link below the data sheet to view a list of released Connectivity products. The System Integration Project Data Sheet (LIT-6900) is found in the Metasys Connectivity Sales Resource Manual (FAN 69). If you need further assistance, contact Johnson Controls Field Support Center. Metasys Integrator Metasys Integrator Cleaver-Brooks Application
26 Notes 6 Metasys Integrator Metasys Integrator Cleaver-Brooks Application
27 Notes Metasys Integrator Metasys Integrator Cleaver-Brooks Application 7
28 Notes Controls Group FAN E. Michigan Street Metasys Connectivity Technical Manual P.O. Box Metasys Integrator Release 9.0 Milwaukee, WI 0 Printed in U.S.A. 8 Metasys Integrator Metasys Integrator Cleaver-Brooks Application
Metasys Integrator TITUS Application
Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date October 12, 2005 APPLICATION NOTE Metasys Integrator TITUS Application lntroduction Page 3 Application
More informationMetasys Integrator Vilter Application
Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 1294 APPLICATION NOTE Metasys Integrator Vilter Application lntroduction Page 3 Application Details *3
More informationMetasys Integrator Compu-Aire Application
Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 0496 APPLICATION NOTE Metasys Integrator Compu-Aire Application lntroduction Page 3 Application Details
More informationMetasys Integrator Airflow Application
Metasys Connectivity Technical Manual 69. Metasys Integrator Section Application Note Issue Date 0998 APPLICATION NOTE Metasys Integrator Airflow Application lntroduction Page Application Details * Component
More informationMetasys Integrator Liebert Application
Application Note Issue Date May, 00 Metasys Integrator Liebert Application lntroduction Application Details Component Requirements 0 Vendor Contact Information Design Considerations Cable Connections Cable
More informationMetasys Integrator York Application
Metasys Connectivity Technical Manual. Metasys Integrator Section Application Note Issue Date 000 APPLICATION NOTE Metasys Integrator York Application lntroduction Page * Application Details * Component
More informationMetasys Integrator McQuay Application
Metasys Connectivity Technical Manual. Metasys Integrator Section Application Note Issue Date 000 APPLICATION NOTE Metasys Integrator McQuay Application Introduction Page * Application Details * Component
More informationModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.
ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page
More informationFire Operator Workstation (Fire OWS) User s Guide
Fire Operator Workstation (Fire OWS) User s Guide 1-1 Fire Operator Workstation (Fire OWS) User s Guide Introduction This user s guide details the components, capabilities, and operation procedures of
More informationReciprocating Chiller
HVAC PRO for Windows User s Manual 637.5 OEM Section Technical Bulletin Issue Date 1094 Reciprocating Chiller Reciprocating Chiller Page 3 Description 3 Theory of Operation 5 Overview 5 Control Sequence
More informationWeekly Testing of Dedicated Stairwell Pressurization Fans- Metasys System Extended Architecture Code No. LIT
Weekly Testing of Dedicated Stairwell Pressurization Fans- Metasys System Extended Architecture Code No. LIT-1201739 Release 1.2 Issued Date July 30, 2004 Supersedes Document Introduction.................................................
More informationFIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD
BURNER MANANGEMENT SYSTEM NXF4000-SPEC AUGUST 5 2017 PRODUCT GUIDE SPECIFICATION FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD GENERAL OVERVIEW 1.1.1. Each burner shall
More informationFigure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick
CAN OBD READER REFERENCE DESIGN KIT USER GUIDE 1. Standard ToolStick Handling Recommendations The ToolStick Base Adapter and daughter cards are distributed without any protective plastics. To prevent damage
More informationModbus RTU RS485 Manual
Modbus RTU RS485 Manual AUTOMATED FUEL MAINTENANCE SYSTEMS FTI-5A, FTI-10A, FTI-20A FUEL TECHNOLOGIES INTERNATIONAL 06/10/2014 Rev B - Fuel Technologies - Modbus The Modbus Communications Setup Button
More informationSOFTWARE INTERFACE SPECIFICATION - SOLA MODBUS INTERFACE
TM SOFTWARE INTERFACE SPECIFICATION - SOLA MODBUS INTERFACE This specificaion interface manual must only be used by a qualified heating installer/service technician. Read all instructions, including this
More informationSuggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)
Furnish and install as shown on AERCO International plans and operation and maintenance manuals, with all applicable codes and authorities having local, state and federal jurisdiction, Benchmark Series
More information21-light Remote Annunciator. Owner s Manual
21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With
More informationDX-9100/9120 Weekly Testing of Dedicated Stairwell Pressurization Fans
Metasys Network Technical Manual 636 DX-9100/9120 Applications Section Application Note Issue Date 0497 APPLICATION NOTE DX-9100/9120 Weekly Testing of Dedicated Stairwell Pressurization Fans Introduction
More informationClearFire - Hydronic Startup Report
ClearFire - Hydronic Startup Report Date Serial No. THIS FORM IS FOR MODEL CFC / CFW CLEARFIRE BOILERS Customer s Name Location Model Design Pressure Working Pressure Rated Input (nameplate rating) BTU/hr
More informationFCD-wire Contents. List of Figures
FCD-wire Contents FCD-X21 Configuration 1 Introduction... 1 2 Opening the FCD Application... 1 3 FCD Window... 2 4 FCD LEDs... 3 5 Configuration Operations... 4 FCD Info...4 FCD System Info...5 FCD Interface
More informationWeekly Testing of Dedicated Smoke Control Dampers - Metasys System Extended Architecture
Weekly Testing of Dedicated Smoke Control Dampers - Metasys System Extended Architecture Code No. LIT-1201743 Release 1.2 Issued Date July 30, 2004 Supersedes Document Introduction.................................................
More informationRefer to Bulletin E-1101 for detailed information on the FLAME-MONITOR System.
The Fireye EP260, EP270 (early spark termination), or EP265 (pilot stabilization) programmer modules are used with the FLAME-MONITOR Burner Management Control System (P/N E110). Several operational characteristics
More informationYork 25-Ton VAV Rooftop Unit
HVAC PRO for Windows User s Manual 637.5 OEM Section Technical Bulletin Issue Date 0996 York 25-Ton VAV Rooftop Unit Introduction Page 3 Overview *3 Configuration 5 Sequence of Operation 7 Modes of Operation
More informationHAWK INTEGRATED BOILER CONTROL SYSTEM
HAWK INTEGRATED BOILER CONTROL SYSTEM The HAWK is a state-of-the-art boiler control system that integrates the functions of a Programmable Controller and Burner Management Controller, as well as other
More informationLMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification
LMV52 Control Product Description February 3, 2017 The LMV52 is a microprocessor-based burner management system with matching system components for the control and supervision of forced draft burners.
More informationHoneywell Modbus Solution: 7800 Series Burner Controller through S7810M Modbus Module
Point Map August 1, 2006 Systems Integration Honeywell Modbus Solution: 7800 Series Burner Controller through S7810M Modbus Module Table 1. 7800 Series Burner Controller through S7810M Modbus Moduler APOGEE
More informationRevitalize Building Mechanical Systems (4619)
SECTION 235216 FIRE-TUBE CONDENSING BOILERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationEOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer
Installation and interface must be performed by a qualified controls technician. IMPORTANT: THIS MANUAL CONTAINS INFORMATION REQUIRED FOR INSTALLATION, INTERFACE AND CONFIGURATION OF THIS EQUIPMENT. READ
More informationDACC - NMDA BUILDINGS
A PROJECT FOR: LAS CRUCES, NEW MEXICO PROJECT LOCATION LOCATION MAP INDEX OF DRAWINGS: CV001 - COVER SHEET M101 - OVERALL CAMPUS STEAM UTILITY PLAN M102 - DACC DAMA 341 PLAN M103 - DACC LRC & CLASSROOM
More informationMicroTech Unit Ventilator
Open Protocol Data Information Packet Version 2.2 Group: Controls Date: April 1996 MicroTech Unit Ventilator Open Protocol Data Communications 2002 McQuay International - C O N F I D E N T I A L - This
More informationHRX Technical Manual. Version 1.2
HRX 5000 Technical Manual Version 1.2 Contents: Specification...2 Connectors...5 RS-485 Network Connectors (J6 and J7)...5 RS-232 to Printer (J19)...6 RS-232 to PC (J8)...7 TCP/IP...8 Power (J21)...9 Fire
More informationACCURATE ELECTRONICS INC
ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A
More informationACT2-CS Convenience Store Controller
Refrigeration Systems Technical Manual 804 Product Bulletins Section Product Bulletin Issue Date 0899 ACT2-CS Convenience Store Controller The ACT2-CS Convenience Store Controller is a fully programmable,
More informationInstruction Manual Model Backup Switch, 1 for 8
Instruction Manual Model 2582-282 Backup Switch, 1 for 8 December 2011, Rev. 0 MODEL 2582 SWITCH CROSS TECHNOLOGIES INC. SWITCH ALARM PSA PSB ALARM OFFLINE ONLINE UNIT STATUS 1 2 3 4 5 6 7 8 BU PROT MODE
More informationDX-9100 Applications from Engineering Services
System 9100 Technical Manual 636.4 Application Examples Section Technical Bulletin Issue Date 0896 DX-9100 Applications from Engineering Services Introduction Page 3 Overview 3 Air Handling Unit Applications
More informationDX-9100/9120 Warehouse Smoke Exhaust and Reset Logic for a Rooftop Unit
Metasys Network Technical Manual 636 DX-9100/9120 Applications Section Application Note Issue Date 0497 APPLICATION NOTE DX-9100/9120 Warehouse Smoke Exhaust and Reset Logic for a Rooftop Unit Introduction
More informationComplete Boiler Management in a Compact, Affordable System
Touchscreen Mini Mk8 Controller Complete Boiler Management in a Compact, Affordable System The Mini Mk8 is a cutting-edge Micro-Modulating system that provides an easily programmable and flexible means
More informationCBI-064. User Manual. Caddx to KNX-BUS Interface
CBI-064 Caddx to KNX-BUS Interface User Manual GDS Intelligence in Buildings El. Venizelou 116 Nea Erithrea 14671 Tel: +30 2108071288 Email: info@gds.com.gr Web: gds.com.gr Contents 1 Device Description...
More informationP2000 and Metasys System Integration
P2000 and Metasys System Integration Product Bulletin Code No. LIT-12011781 Software Release 3.12 Issued June 20, 2013 Supersedes April 20, 2012 Refer to the QuickLIT Web site for the most up-to-date version
More informationSCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification
February 11, 2019 Master Panel Product Description The Master Panel shall provide lead/lag control and time based, automatic rotation of up to eight (8) boilers, when used in conjunction with LMV3 or LMV5
More informationUSER MANUAL FOR OPERATING SYSTEM
P2262 ALARM PANEL USER MANUAL FOR OPERATING SYSTEM 21765-07 September 1999 Associated Controls (Aust) PTY. LTD. 29 Smith Street, Hillsdale, NSW, 2036. PH (02) 9311 3255, FAX (02) 9311 3779 Page 1 of 177
More information7800 SERIES RM7840E,G,L,M; EC7840L Relay Module
7800 SERIES RM7840E,G,L,M; EC7840L Relay Module SPECIFICATION DATA Valve Proving features including: VPS test time When (Never, Before, After, Split or Both) FEATURES APPLICATION The Honeywell RM7840 is
More informationTEC Networked Multi-Stage Economizer Thermostat
Installation Instructions Issue Date January 19, 2005 TEC2104-2 Networked Multi-Stage Economizer Thermostat Application The TEC2104-2 thermostat is an N2 networked thermostat that provides control of single-
More informationClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler
ClearFire Model CFH Horizontal Steam Boiler Startup Guide 750-293 www.cleaverbrooks.com Improper installation, adjustment, service, or maintenance can cause equipment damage, personal injury, or death.
More information7800 SERIES: EC7895A,C; RM7895A,B,C,D; RM7896A,B,C,D RM7897A,C and RM7898A Relay Modules
7800 SERIES: EC7895A,C; RM7895A,B,C,D; RM7896A,B,C,D RM7897A,C and RM7898A Relay Modules SPECIFICATION DATA The RM7897A1002 offers selectable pilot operation, intermittent on terminal 8 or interrupted
More informationDGC-1000 DIGITAL GENSET CONTROLLER
DGC-1000 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-1000) offers a low cost microprocessor based integrated alternative for small to medium sized genset control and monitoring.
More informationMetasys System Extended Architecture Smoke Control UL 864 UUKL Compliance
Metasys System Extended Architecture Smoke Control UL 864 UUKL Compliance Checklist Code No. LIT-1201754 Release 1.2 Issued February 10, 2005 Document Introduction.................................................
More informationCONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.
CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse
More informationManual Supplement. Product/System Title: Static Pressure Controller. Contents of this manual supplement include:
Model Number: Product/System Title: 8635-ST Static Pressure Controller Contents of this manual supplement include: 1) Sequence of operation 2) Description of new software items 3) Deleted software menu
More informationReplaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge
Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays
More informationPower Flame Incorporated
Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone: 620-421-0480,
More informationV10 Controller - BACnet lnterface Supplement 1
V10 Controller - BACnet lnterface Supplement 1 1 BACnet Interface IBC s BACnet Interface option provides BACnet Server functionality to the V10 Touch Screen Boiler Controller using a BACnet/IP interface.
More informationModel A1700 Series Annunciator
Seekirk Model A1700 Series Annunciator Applications: For usage in all types of process industries, electric generation, transmission and distribution, gas and water utilities. Features: The Seekirk model
More informationSTEAMPAK Series BurnerPAK BMS Burner Management Systems
BurnerPAK BMS Burner Management Systems Sequence of operation, ignition and control of burners Meets NFPA 85 safety standard MFT alarming with manual reset, first-out indication Optional enhanced alarming
More informationCentaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE
Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE General Description This guide provides a summary for installing and configuring the Centaur TM Cube Slave Alarm Signalling Equipment
More informationEach burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.
Product Guide Specification Nexus Integrated Burner Control System 1. General 1.1 Overview Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning
More informationRS485 MODBUS Module 8AI
Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationFIREYE YZ300 and YZ320 INTERLOCK ANNUNCIATOR For use with the Fireye BurnerLogix Control
YZEM-3001 June 2, 2017 FIREYE YZ300 and YZ320 INTERLOCK ANNUNCIATOR For use with the Fireye BurnerLogix Control APPROVED DESCRIPTION The FIREYE YZ300 (YZ320) Interlock Annunciator Module provides increased
More informationFire System Objects. Introduction Page *3. Engineering *17. Data Base Generation *43
Metasys etwork Technical Manual 636 Objects Section Technical Bulletin Issue Date 696 Fire System Objects Introduction Page *3 Description *3 Purpose *5 Capabilities *7 Functional Diagram *1 Operator Interface
More informationED510 DISPLAY MODULE. FOR USE WITH FIREYE FLAME-MONITOR AND MicroM BURNER MANAGEMENT CONTROLS DESCRIPTION INSTALLATION APPROVED
ED-5101 APRIL 3, 2013 ED510 DISPLAY MODULE FOR USE WITH FIREYE FLAME-MONITOR AND MicroM BURNER MANAGEMENT CONTROLS APPROVED DESCRIPTION The ED510 Display Module is designed to operate with the FLAME-MONITOR
More information7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules
7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules SPECIFICATION DATA FEATURES APPLICATION The Honeywell EC7895/RM7895/RM7896 is a microprocessor based integrated burner control for automatically
More informationME 3011C / Alarm Indication / Quick Reference Guide
Tables of Contents Page Application 1 Features 1 Important Safety Information! 2 Note to this Guide 2 Further Information 2 Device Variants 2 General Functions 3 Annunciator Sequences - ISA 18.1 3 Plan
More informationMicroTech Series-200 Flooded Screw Chiller
Open Protocol Data Infomation Packet Version 1.0 Group: Controls Date: February 1997 MicroTech Series-200 Flooded Screw Chiller Open Protocol Data Communications 2002 McQuay International - C O N F I D
More informationAdded password for IP setup page : Password must be in IP format!
NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP
More informationMicroTech Series 200 Centrifugal Chiller
Protocol Data Information Packet Version 2.2 Group: Controls Date: March 1999 MicroTech Series 200 Centrifugal Chiller Data Communications Packet for Protocol 2002 McQuay International Revision History
More informationHIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER
This manual must be left with owner and should be hung on or adjacent to the boiler for reference. US HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER MODELS CHS-85 through CHS-399 APPENDIX A CONTROLLER
More informationP2000 and Metasys System Integration
P2000 and Metasys System Integration Product Bulletin Code No. LIT-12012141 Software Release 3.14 SP1 Issued June 23, 2017 The Johnson Controls P2000 Security Management System supports the integration
More informationDX-9100/9120 Local Sonalert Logic
Metasys Network Technical Manual 636 DX-9100/9120 Applications Section Application Note Issue Date 0497 APPICATION NOTE DX-9100/9120 ocal Sonalert ogic Introduction Page 3 Application Description *3 Design
More informationOPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL
ap15_2manual04/22/13 Page 1 4/22/2013 1 Serial Number : Option: OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL Micro Seven, Inc. 1095-K N.E. 25th Hillsboro, OR 97124 U.S.A. phone: 503-693-6982
More informationLATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners
1 1. General Installation Information (to be completed by technician) Date installed: Location (city & state): Cleaner s name: National Board number (boiler): Installed by (company): Installed by (technician):
More information725B Configuration Software Manual
725B Configuration Software Manual REV DATED DESCRIPTION AUTHOR APPROVED 0 09-03-10 First Issue P.Cartmell Page 1 of 80 SECTION 1 - SOFTWARE INSTALLATION... 5 725B ConfigurationSoftware Installation...
More informationrvm4c Installation Guide Remote Video Module
rvm4c EN Installation Guide Remote Video Module rvm4c Installation Guide Installation Diagrams EN 2 Installation Diagrams for the Transmitting Unit rvm4c Installation Guide Basic Hardware Installation
More informationM2500 Engine Controller Installation Manual
M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...
More informationLMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification
SCC Inc. LMV51 Control Product Description February 7, 2017 The LMV51 is a microprocessor-based burner management system with matching system components for the control and supervision of forced draft
More informationADAC. Advanced Deaerator Control
The Advanced Deaerator Control System ADAC Advanced Deaerator Control MAXIMum safety and efficiency for steam applications One package from a single source supplier Features in an easy-to-use interface
More informationBGH Series Hot Surface Ignition Control
Installation Instructions BGH Series Issue Date April 14, 2011 BGH Series Hot Surface Ignition Control Application The BASO Gas Products BGH Series Hot Surface Ignition (HSI) control is microprocessor
More informationK-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform
Versa IC Platform VERSA IC Integrated Control Platform Raypak s VERSA IC combines modulating temperature control, safety limits, and ignition programming into one user- friendly Integrated Control Platform.
More informationTri-Stack Smart System
Tri-Stack Smart System TM Notes & Warnings - The protection provided by this equipment may be impaired if it is not used in the manner specified herein. - Ensure all wiring meets applicable national and
More informationINSTALLATION AND OPERATION MANUAL FOR THE PILOTEYE 2000
Installation & Operation Manual Page 1 INSTALLATION AND OPERATION MANUAL FOR THE PILOTEYE 2000 Release 1.0 11920 East Apache P.O. Box 21220 Tulsa Oklahoma 74121-1220 (918) 234-1800 -other offices located
More informationNGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1
NGC-40 Bridge Overview Raychem-AR-H58862-NGC40BridgeOV-EN-1805 nvent.com 1 Table of Contents 1. NGC-40 Overview... 9 1.1 Example NGC-40 System... 10 2. Legal stuff... 11 3. Protocols... 12 3.1 Data es...
More informationTC-9102 Applications
Application Note January 7, 2004 APPLICATION NOTE TC-9102 Applications Configuring TC-9102 Applications...3 Introduction... 3 Key Concepts... 4 TC-9102 Controller... 4 Control Modes...8 Procedure Overview...
More informationACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX
Page 1 of 10 Model 10807800 January 2014 ACCURATE ELECTRONICS INC PO BOX 1654 97075-1654 8687 SW HALL BLVD 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 WWW.ACCURATE.ORG Practice Section 10807800
More informationB-40/B-41 Modulating Temperature Controller
INSTALLATION & OPERATING INSTRUCTIONS B-40/B-41 Modulating Temperature Controller For Raytherm Boilers & Water Heaters H2 514-4001 WH2 2100-4001 Catalog No. 5000.70 Effective: 12-21-11 Replaces: NEW P/N
More informationION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document
70072-0125-01 TECHNICAL NOTE NOVEMBER 2006 ION Meter Alerts A PowerLogic ION meter can send alerts to indicate a user specified power system condition such as a power quality problem (including surges,
More informationINSTALLATION INSTRUCTIONS
www.altronicinc.com INSTALLATION INSTRUCTIONS WARNING: WARNING: DEVIATION DEVIATION FROM THESE FROM INSTRUCTIONS THESE INSTRUCTIONS MAY LEAD MAY TO IMPROPER LEAD TO OP- ERATION OF IMPROPER THE MACHINE
More informationLineGuard 2300 Program User Manual (FloBoss 107)
Form A6251 Part Number D301346X012 November 2012 LineGuard 2300 Program User Manual (FloBoss 107) Remote Automation Solutions Revision Tracking Sheet November 2012 This manual may be revised periodically
More informationPROFIRE BMS Controller
PF3100 BMS Controller Shutdown Summary August 2017 BMS Controller Shutdown Summary solutions@profireenergy.com Page 1 of 6 PF3100 UV Pilot Card Product Manual 1. Introduction This document is a reference
More informationPBI Manual. Paradox to KNX-BUS Interface
PBI 64-192 Paradox to KNX-BUS Interface Manual GDS Intelligence in Buildings El. Benizelou 116 Nea Erithrea, 14671 Phone: +30 2108071288 Email: info@gds.com.gr Web: gds.com.gr Contents 1 Device description...
More informationER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller
PB_ER65-DRW_ 202 ER65-DRW Controller Heating Applications Product Bulletin The controller is a digital device for domestic or residential heating units. It covers water and air heating applications. All-in-one
More informationER65 - Mini Rack Controller Electronic Refrigeration Line
PB_ER65_ 00 ER65 - Mini Rack Controller Electronic Refrigeration Line Device is a multi-stage digital controller. It is typically applied to small refrigeration rack units piloting compressors or condenser
More informationP2267 NETWORK INTERFACE
P2267 NETWORK INTERFACE USER MANUAL FOR OPERATING SYSTEMS: 22031-03 23636-01 October 2009 Associated Controls (Australia) Pty. Limited 2-4 Norfolk Road Greenacre, NSW, 2190. PH +61 2 9642 4922, FAX +61
More informationLaptop / PC Programming Manual
Laptop / PC Programming Manual Doc. # Fire PC Program rev B 01.07 This Document is property of Evax Systems, Inc. The Evax Fire Solutions Programmer Components 2 1.0 System Setup 4 1.1 Interface Setup
More informationConcert TM Boiler Control
Concert TM Boiler Control Instruction and Operation Manual Form 105975-01; Revision 7 Contents April 15, 2016 Introduction Quick Reference 2 Overview 3 Product Features Boiler Sequence 5 Protection Features
More informationINSTALLATION INSTRUCTIONS
TT-1343 5/06b INSTALLATION INSTRUCTIONS Original Issue Date: 8/03 Model: Automatic Transfer Switches Equipped with Series 1000 Programmable Controller Market: ATS Subject: Remote Annunciator Kits GM28938-KP1,
More informationDC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1
DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS User Manual and Menu Map A4741 / Rev.1 www.entes.com.tr ATTENTION -Disconnect all power before connecting the device. -Don t remove
More informationibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems
Honeywell Life Safety Iberia C/Pau Vila 15-19; 08911 Badalona Barcelona T. 902 03 05 45; Internacional:+34932424236 www.honeywelllifesafety.es infohlsiberia@honeywell.com ibox Modbus Server Gateway for
More informationMetasys Integrator Carrier Application
Application Note Issue Date April 15, 2003 Metasys Integrator Carrier Application lntroduction 3 Application Details 3 Component Requirements 6 Vendor Contact Information 7 Design Considerations 7 Cable
More informationA-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents
Boiler specifications A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents Burner General: Q. Burner and burner safeguards shall comply with the CGA
More informationElectronic Pellet Burner Controller NPBC-V3-1
Electronic Pellet Burner Controller NPBC-V3- SOFTWARE VERSION 3.2/3. page of 3 CHANGES IN THE TECHNICAL AND USER GUIDE OR IN THE SOFTWARE VERSION Technical and User Guide's version Changes Page 2.8. The
More informationMiLAB Oxygen Control MANUAL & INSTALLATION. MOC-100 Ver 3.0
MiLAB Oxygen Control MANUAL & INSTALLATION MOC-100 Ver 3.0 Contents 1 INTRODUCTION...3 2 FUNCTIONS...4 2.1 O 2 REGULATION...4 2.2 DISPLAY BOARD...4 2.3 COMMUNICATION THROUGH PANEL...5 2.3.1 Set parameters...5
More information