CALL YOUR SALES CONSULTANT TODAY,

Size: px
Start display at page:

Download "CALL YOUR SALES CONSULTANT TODAY,"

Transcription

1 38 Filtered Regulated AL175ULX AL300ULM AL300ULX AL400ULM AL400ULX AL600ULM AL600ULX AL1024ULX STRIKEIT1 AL175ULX; 1.75 AMP; 115VAC input; latching/non latching fire alarm disconnect; grey enclosure; 13.5H x 13 W x 3.25 D; UL listed; Batteries sold separately. AL300ULM; 12/24VDC@ 2.5 AMP; fire alarm interface; AC and battery monitoring; class 2 rated; enclosure; 13.5H x 13 W x 3.25 D; UL listed ; Batteries sold separately. AL300ULX; 12/24VDC@ 2.5 AMP; 115VAC input; AC and battery monitoring; class 2 rated; grey enclosure; 13.5H x 13 W x 3.25 D; UL listed; Batteries sold separately. AL400ULM; 4 AMP or 3 AMP; fire alarm interface; AC and battery monitoring; class 2 rated; enclosure; 13.5H x 13 W x 3.25 D; UL; Batteries sold separately. AL400ULX; 4 AMP or 3 AMP; 115VAC input; AC and battery monitoring; class 2 rated; grey enclosure; 13.5H x 13 W x 3.25 D; UL; Batteries sold separately. AL600ULM; 6 AMP; fire alarm interface; AC and battery monitoring; non-power limited output; enclosure; 13.5H x 13 W x 3.25 D; UL/ CUL; Batteries sold separately. AL600ULX; 6 AMP; 115VAC input; AC and battery monitoring; nonpower limited output; grey enclosure; 13.5H x 13 W x 3.25 D; UL/CUL; Batteries sold separately. AL1024ULX; 10 AMP; 115VAC input; AC and battery monitoring; nonpower limited output; grey enclosure; 15.5H x 12 W x 4.5 D; UL/CUL; Batteries sold separately. STRIKEIT1; two 24VDC independent or simultaneously controlled outputs for panic devices; programmable timed lock release; two relay outputs; UL; Batteries sold separately

2 39 Controllers Linear CCTV MAXIM3 MAXIM7 AL600ULACM AL624ET AL624 ALTV248UL ALTV248175UL ALTV248300UL Access Controller; Product No. MAXIM3; 6AMP; 115VAC input; AC and battery monitoring; 16 failsafe and/or fail secure power outputs or dry form C outputs. Access Controller; Product No. MAXIM7; 10AMP; 115VAC input; AC and battery monitoring; 16 failsafe and/or fail-secure power outputs or dry form C outputs. UL Listed Access Controller; Product No. AL600ULACM, Access power controller providing a total of eight (8) fuse protected Fail-Safe and/or Fail-Secure non-power limited outputs or dry form C outputs, Fire Alarm disconnect selectable by output. Unit includes one (1) power supply/charger which is 12VDC or 6 amp, 115VAC input, AC and battery monitoring. Grey enclosure 15.5 H x 12 W x 4.5 D. Accommodates up to two (2) 12VDC/ 12AH batteries, sold separately. UL/CUL Listed (UL294) CSFM and MEA Approved. Linear Supply; Product No. AL624ET;1.2 6VDC/12VDC or.75 24VDC; plug-in transformer required; grey enclosure; 8.5H x 7.5 W x 3.5 D; fits 1 7ah or 2 4ah. Linear Supply Board; Product No. AL624; 1.2 6VDC/ 12VDC or.75 24VDC; plug-in transformer required. CCTV Supply; Product No. ALTV248UL; U.L. Listed CCTV Supply, Eight (8) fuse protected outputs. 3.5 amp (85VA) or 3 amp (85VA,) 115VAC input. Grey enclosure 8.5 H x 7.5 W x 3.5 D. UL Listed (UL2044) CUL Listed and CE Approved. CCTV Supply; Product No. ALTV248175UL; 8 fuse protected outputs; 7AMP; 115VAC input; grey enclosure; 12.25H x 7.75 W x 4.5 D; UL/CUL listed. CCTV Supply; Product No. ALTV248300UL; 8 fuse protected outputs; 12.5AMP; 115VAC input; grey enclosure; 13H x 13.5 W x 3.25 D; UL/ CUL listed

3 40 CCTV CCTV Baluns Batteries HubWay8D HubWayLD16D Vertiline16 HubWayAv HubwayDv BT126 BT1212 BT1240 CCTV Supply; Product No. HubWay8D; Passive UTP Transceiver Hubs with Integral, Eight (8) Channel Passive UTP Transceiver Hub with Integral Camera, Video/Data up to 750 ft., 5 amp total current, 24VAC and/or 28VAC PTC protected power outputs are selectable by channel, 1U EIA 19 Rack Mount Chassis, 115/230VAC Input 50/60Hz. CCTV Supply; Product No. HubWayLD16D; Passive UTP Transceiver Hubs with Integral, Sixteen (16) Channel Passive UTP Transceiver Hub with Integral Camera, Video/Data up to 750 ft., 10 amp total current, 24VAC and/or 28VAC PTC protected power outputs are selectable by channel, 1U EIA 19 Rack Mount Chassis, 115/230VAC Input 50/60Hz. 1U Rack Mount AC CCTV Supply; Product No. Vertiline 16, 16 - fuse protected outputs, 24VAC or 28VAC selectable by output, 10 amp total current, 1U EIA 19 Rack Mount Chassis, 115/230VAC Input. Video Balun; Product No. HubWay Av; Combiner for 24VAC Cameras. Video Balun; Product No. HubWay Dv; Combiner for 12VDC Cameras. Battery; Product No. BT126; 12VDC/7AH; 3.66H x 5.94 W x 2.56 D; lead acid rechargeable battery. Battery; Product No. BT1212; 12VDC/12AH; 3.5H x 5.94 W x 3.75 D; lead acid rechargeable battery. Battery; Product No. BT1240; 12VDC/40AH; 6.73H x 7.72 W x 6.5 D; lead acid rechargeable battery Accessories BC1240 Enclosure; Product No. BC1240; 9.5H x 9.5 W x 7.5 D; 19 ga. steel; includes cam lock; fits one 12VDC/40AH battery; gray

4 41

5 42 Modules MOM5C VB1 VR1 Distribution Module; Product No. MOM5C; 2 12VDC or 24 VDC; fire alarm interface; 5 class 2 rated outputs; enclosure; 8.5H x 7.25 W x 3.5 D; UL/CUL listed. Conversion Module; Product No. VB1; 12-24VDC input to regulated amp output; modular connector/cable assembly; high impact insulated housing. Conversion Module; Product No. VR1; 24VAC or 24VDC input to 1 amp output; modular connector/cable assembly; high impact insulated housing RB5 RBSN Relay Module; Product No. RB5; 6VDC or 12VDC operation. 5 amp/115vac/28vdc DPDT contacts. Coil draws 120mA. Relay Module; Product No. RBSN; Sensitive Relay - 12VDC or 24VDC operation. 2 amp/115vac/28vdc DPDT contacts. 1,000 ohm coil draws only 10mA TRANSFORMERS TP1220 Plug-in Transformer; Product No. TP1220; 12VAC/20VA; 120VAC input Plug-in Transformers TP1640 Plug-in Transformer; Product No. TP1640; 16VAC/40VA; 120VAC input TP2440 Plug-in Transformer; Product No. TP2440; 24VAC/40VA; 120VAC input Filtered, Regulated Supply SMP3 High Current Supply Board; Product No. SMP-3; 6VDC, 12VDC or 2.5 amp

6 TRANSFORMERS PI-12 Schlage Plug-In Transformer; Product No. 593PI-12; 12 VAC output; 1 amp maximum; UL listed Plug-In Transformers 593PI-24 Schlage Plug-In Transformer; Product No. 593PI-24; 24 VAC output; 1 amp maximum; UL listed Schlage Electronics 593PI-12DC Schlage Plug-In Transformer; Product No. 593PI-12DC; 12VDC output; 1 amp maximum; UL listed /24 VAC Schlage Hard Wired Transformer; Product No /24 VAC output; hard wired 12 or 24 VAC output; 1.67 amp maximum Hard Wired Transformers RC 24VDC Schlage Hard Wired Transformer; Product No RC; 24 VDC output; 1.67 amp maximum IEI Plug-In Transformer PIP12VDC PIP24VDC IEI Plug-in Supply; Product No. PIP12VDC; integrates the filtering and suppression of a power supply with the ease of a plug-in transformer; LED indication of power output; 12VDC power. IEI Plug-in Supply; Product No. PIP24VDC; 24V DC power; integrates the filtering and suppression of a power supply with the ease of a plug-in transformer; LED indication of power output TP2440 SDC Plug-In Transformer; Product No. TP2440; 24VAC; 1.65 Amp; 120VAC primary, secondary screw terminals fused SDC Plug-In Transformer PSP-24 Securitron Plug-In DC Supply; Product No. PSP-24; 700mA; internal thermal fuse; 16 output cable

7 44 SPECIALTY Schlage Bright Blue SPS-5ELG Schlage Supply; Product No. SPS- 5ELG; 14x14 x4.75 enclosure; for SBB controller or reader interface; current output, 5 amp at 24 VDC; UL listed;(2) 12VDC 7AH batteries incl Keri KPS-5 Keri Supply; Product No. KPS- 5; 12VDC; with enclosure; 2 amp; with battery charger circuit Von Duprin 631RF SDC Supply; Product No. 631RF; 11-1/2 Hx11-1/2 Wx3-1/2 D; 1.5 amp; 12/24VDC selectable; regulated output; holds 2 door control modules; battery charger; Batteries sold separately PS861 Von Duprin Supply; Product No. PS861; field selectable 24VDC or 12VDC; designed for electromagnetic locks and electric strikes on single door applications PS873 Von Duprin Supply; Product No. PS873; field selectable 24VDC or 12VDC; operates wide variety of electrical products Von Duprin Filtered Regulated PS PS873-4TD Von Duprin Two Zone Supply; Product No. PS873-2; 10 x 12-1/2 x 5 ; operates 2 electrical products such as 2 EL (electric latch retraction devices); 12 or 24VDC field select. Von Duprin Supply; Product No. PS873-4TD; field selectable 24VDC or 12VDC; operates wide variety of electrical products; includes 4 zone controller with time delay PS873-B Von Duprin Supply With Battery; Product No. PS873B; field selectable 24VDC or 12VDC; operates variety of electrical products PS873 BBX2 Von Duprin Supply With Battery; Product No. PS873BBX2; will operate 2 EL exit devices; provides two inputs and two outputs; key lock secures cover; battery back-up

8 SUPPLY OPTION BOARDS 45 Von Duprin Supply Option Boards AO 873-4TD 873-BB 873-FA Von Duprin Two Zone Controller Circuit Card; Product No ; two inputs and two outputs; will operate two EL exit devices; board only; does not include power supply. Von Duprin Auto Operator Board; Product No. 873-AO; coordinates the release of one or two locks and signals an autooperator to open a door; does not include power supply. Von Duprin Four Zone Controller; Product No TD; provides four inputs and outputs with time delay; time delay from 0-75 seconds; controller only; does not include power supply. Von Duprin Battery Back-Up; Product No. 873-BB; provides two hours backup power at full load during AC power failure; battery only; does not include power supply. Von Duprin Fire Alarm Board; Product No. 873-FA; provides input for a normally closed fire alarm contact if open power is removed; board only; does not include power supply SUPPLY ACCESSORIES Von Duprin SO-12 SO-24 Von Duprin Rectifier Kit; Product No. SO-12; AC only rectifier; permits quiet operation when using AC voltage to operate the electric strike. Von Duprin Rectifier Kit; Product No. SO-24; AC only rectifier; permits quiet operation when using AC voltage to operate the electric strike Schlage Electronics Rectifiers RCP Schlage Pre-Wired Rectifier; Product No. RCP; 12 or 24 V operation SDC BR64XL SDC Rectifier; Product No. BR64XL; to convert AC to DC voltage Securitron BR-7 Securitron Rectifier; Product No. BR-7; bridge rectifier; 7 amp; will convert an AC input to full wave rectified DC output

9 46 SUPPLY ACCESSORIES Securitron MOV MOV Securitron MOV; Product No. MOV; protects against possible inrush and reverse surges BATTERY UPDATE Chown highly recommends battery backup for all of their EAC systems. Batteries have a limited life, a one year warranty, and should be replaced every 3 years. Factors that adversely affect performance include, long conductor runs, additional openings added to the controller, and if completely drained of power the batteries may fully not recharge. Frequent voltage verification is encouraged. This does not apply to stand alone or wireless locks. Their battery life is determined by number of transactions. Please refer to manufacturer s suggested life for required replacement. BATTERIES PC1300 PC1300; D alkaline battery PC1400 PC1400; C alkaline battery Duracell PC1500 PC1500; AA alkaline battery Batteries PC1604 PC1604; 9V alkaline battery PC2400 PC2400; AAA alkaline battery Werker WKA12 Werker Battery; Product No. WKA12-7.5F; 12 volt/7 AH; 3.74H x 5.94 L x 2.56 W; lead acid rechargeable battery Schlage Electronics SBP2 Schlage Standby Battery Pack; Product No. SBP 2; pair of 12 VDC 4 Amp/Hour batteries for 24 VDC systems; cable kit provides hardware for proper hookup of up to two batteries

more than just power! Altronix is the professional security industry s leading manufacturer

more than just power! Altronix is the professional security industry s leading manufacturer altronix.com more than just power! Altronix is the professional security industry s leading manufacturer and designer of low voltage electronics that deliver more than just power. With its global reputation

More information

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction Riser and Point-to-Point Drawings for Standard Access Control Applications Using Maintained Latch Retraction Control or Momentary

More information

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger Installation Guide for AL300ULM Multi-Output Access Control Power Supply Charger R AL300ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL300ULM multi-output access control power supply/charger

More information

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger Installation Guide for AL400ULM Multi-Output Access Control Power Supply Charger R AL400ULM - Multi-Output Access Control Power Supply/Charger Rev. 072500 Overview: The AL400ULM multi-output access control

More information

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC. M Series Multi-Output Access Control Power Supply Chargers Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 3 amp @ 12VDC or 4 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp

More information

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC. M Series Multi-Output Access Control Power Supply Charger Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 4 amp @ 12VDC or 3 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp @

More information

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev Installation Guide for AL600ULM Multi-Output Access Control Power Supply Charger Rev. 091800 1 AL600ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL600ULM multi-output access control

More information

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations: F1! 44487023 These instructions cover the following parts: PS902 Power Supply Installation Instructions! DANGER: To avoid risk of electric shock, turn off AC power before installing or servicing PS902

More information

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F II 1400-2 ACSI 1406-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F INSTALLATION Transformer Model BE31763001 by Basler Electric, Transformer Model 2010028 by Galaxy

More information

Power Supplies. Overview

Power Supplies. Overview Power Supplies Overview Access control provides enhanced security, audit trails, and custom credentials. The power supply is necessary to make the entire system operational. Power supplies offer accurate

More information

Rack Mount Series Installation Guide

Rack Mount Series Installation Guide Rack Mount Series Installation Guide Models Include: Maximal1RHV Maximal1RV - 12VDC @ 4 amp or 24VDC @ 3 amp. - 12VDC @ 4 amp or 24VDC @ 3 amp. - Eight (8) Fuse Protected Outputs. - Sixteen (16) Fuse Protected

More information

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES POWER SUPPLY AND BATTERY CHARGER AC AND DC STATUS INDICATORS ENOUGH POWER TO SUPPORT UP TO 3 MAGLOCKS OR ELECTRIC STRIKES PLUS REQUIRED

More information

AL600ULX Series. Power Supply/Charger. Installation Guide

AL600ULX Series. Power Supply/Charger. Installation Guide AL600ULX Series Power Supply/Charger Installation Guide Models Include: AL600ULX - Single Output AL600ULPD4 AL600ULPD4CB - Four (4) Fused Outputs - Four (4) PTC Outputs AL600ULPD8 AL600ULPD8CB - Eight

More information

SP-1000X. Panic Device Power Controller Installation Guide. Rev

SP-1000X. Panic Device Power Controller Installation Guide. Rev TM SP-1000X Panic Device Power Controller Installation Guide Rev. 120213 Overview: SP-1000X will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed to handle the high current

More information

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev RPSMLR2 RPSMLR2BB Panic Device Power Controller Installation Guide LISTED Rev. 102715 Overview: RPSMLR2BB, RPSMLR2 will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed

More information

Installation Guide for models:

Installation Guide for models: 140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal11F - Power Supply 1: 12VDC @ 3.3 amp or 24VDC @ 3.6 amp. - Power Supply 2: 12VDC @ 3.3 amp

More information

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs AL400ULX Series Power Supply/Charger Installation Guide Models Include: AL400ULX - Single Output AL400ULPD4 AL400ULPD4CB - Four (4) Fused Outputs - Four (4) PTC Outputs AL400ULPD8 AL400ULPD8CB - Eight

More information

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs ACM Series Access Power Controllers with Power Supplies Installation Guide Models Include: AL400ULACM AL600ULACM - 12VDC @ 4 amp - 12VDC or 24VDC @ 6 amp. or 24VDC @ 3 amp - Fused Outputs - Fused Outputs

More information

/ How To Order

/ How To Order 84-800 / 85-800 How To Order SERIES 84 = 1.0A continuous (powers and controls 1 EExER device with signal output for 1 operator) 85 = 2.0A continuous (powers and controls EExER device for 1 pair of doors

More information

631RF Amp Power Supply

631RF Amp Power Supply 631RF - 1.5 Amp Power Supply Modular Access Control Power Supply Field Selectable 12VDC or 24VDC Output - Standard Dual 12VDC and 24VDC Output - Optional Quality, Performance and Versatility The SDC 631RF

More information

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information: RDM LOCK G-1 1400 Series Electromagnetic Lock The patented 1400 Series Electromagnetic Lock is universal for all types of applications, including outdoor use. The innovative design will reduce installation

More information

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK Installation Manual AQM-20 12vdc/24vdc Series Power Supplies AQM20 Supervised Power Supply/Charger 12vdc 20Amp/24vdc 10Amp Life Time Warranty Quality Manufactured in the USA AQM20 Features: The AQM20 has

More information

Installation Guide for models:

Installation Guide for models: 140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal3FD - 12VDC @ 4.6 amp or 24VDC @ 5.2 amp. - Sixteen (16) PTC protected power-limited outputs.

More information

Series. Access Power Controllers. Installation Guide

Series. Access Power Controllers. Installation Guide Series Access Power Controllers Installation Guide Models Include: Maxim11 - Power Supply 1: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Power Supply 2: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Sixteen (16) fuse

More information

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories System components portfolio overview Power supplies, electromagnetic locks, electric strikes and system accessories Our comprehensive commercial portfolio includes everything you need to hang, protect,

More information

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs AL300ULX Series Power Supply/Charger Installation Guide Models Include: AL300ULX - Single Output AL300ULPD4 AL300ULPD4CB - Four (4) Fused Outputs - Four (4) PTC Outputs AL300ULPD8 AL300ULPD8CB - Eight

More information

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation PS6 SERIES Power Supplies PS6 SERIES Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation and Specifications Manual ISDPS6_SERIES 08121590 PCN15016 R05/15GR

More information

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804 #4202 2 amp #4204 4 amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL 4202/4MA, Rev. E 0804 4202/4204 Power Supply Fused 115 V Input Low Battery Indicator DC Output Adjustable 0.7 to 3.7 Volts from nominal

More information

AL600ULADA. NAC Power Extender. Installation Guide

AL600ULADA. NAC Power Extender. Installation Guide AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery

More information

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep. Power Supply/Chargers Installation Guide Models Include: eflow4na8d - 4A @ 12VDC or 24VDC - Eight (8) PTC Outputs eflow6na8d - 4A @ 12VDC or 24VDC - Eight (8) PTC Outputs eflow102na8d - 10A @ 12VDC - Eight

More information

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep. 140 58th St. Brooklyn, NY Power Supply/Chargers Installation Guide Models Include: eflow4n/eflow4nx - 4 amp @ 12VDC or 24VDC eflow4n8/eflow4nx8 eflow4n8d/eflow4nx8d - 4 amp @ 12VDC or 24VDC - 4 amp @ 12VDC

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 031703 Overview: The Altronix AL802ULADA is an extremely cost effective 8 amp voltage regulated

More information

LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE

LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE MODIFICATIONS TO: ADAMS RITE ARROW CORBIN RUSSWIN DORMA DOROMATIC MONARCH PRECISION SARGENT VON DUPRIN YALE and more SERIES 1500 EXIT DEVICES CATALOG

More information

APPENDIX F: LOCKSETS AND ACCESS CONTROL

APPENDIX F: LOCKSETS AND ACCESS CONTROL APPENDIX F: LOCKSETS AND ACCESS CONTROL F.1 LOCKSETS The University, with the exception of the Housing Division which uses a Best 7-pin system, utilizes a Corbin Russwin 7-pin IC Core keying system. Locksets

More information

Model 4001 Series Single Channel Controller

Model 4001 Series Single Channel Controller Model 4001 Series Single Channel Controller Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 (800) 727-4377 (408) 262-9042 - Fax E-Mail: sales@sierramonitor.com Web site:

More information

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual INSTALLATION 10-175UL Power Supply 10-175UL Access Control Power Supply/Charger Installation and Specifications Manual Overview The 10-175UL is a power limited power supply/charger that will convert 115VAC

More information

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev Installation Guide for AL800UL-ADA NAC Power Extender Rev. 090500 Overview: The Altronix AL800UL-ADA is an extremely cost effective 8 amps voltage regulated remote power supply /battery charger. The AL800UL-ADA

More information

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01 PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Warnings and Notices WARNING - To reduce the risk of fire or electric shock, do not expose this product

More information

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep. Power Supply/Chargers Installation Guide Models Include: eflow4na8-4a @ 12VDC or 24VDC - Eight (8) Fused Outputs eflow6na8-4a @ 12VDC or 24VDC - Eight (8) Fused Outputs eflow102na8-10a @ 12VDC - Eight

More information

Access Power Controllers with Power Supplies

Access Power Controllers with Power Supplies Access Power Controllers with Power Supplies Installation Guide Models Include: Maximal11FD - Power Supply 1: 12VDC @ 3.3A or 24VDC @ 3.6A. - Power Supply 2: 12VDC @ 3.3A or 24VDC @ 3.6A. - Sixteen (16)

More information

SLX Power. modular power system listed for all low voltage needs Access / Fire / Security / CCTV / Mass Notification

SLX Power.  modular power system listed for all low voltage needs Access / Fire / Security / CCTV / Mass Notification SLX Power Enhanced features for tomorrow's challenges modular power system listed for all low voltage needs Access / Fire / Security / CCTV / Modular, flexible expandable, reliable u Pre-wired and listed

More information

June 10, 2002 DF C S2424

June 10, 2002 DF C S2424 GENERAL www.firelite.com The Fire Lite FIRE COMMAND 25/50X is a state-of-theart Emergency Voice Evacuation Control Panel (VECP), with significant technological enhancements that set it apart from other

More information

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN 04-350 Product Installation

More information

Excel-EN Conventional Fire Control Panel

Excel-EN Conventional Fire Control Panel Available as 2, 4, 6, 8,10 or 12 zones Approved to EN54-2 & 4 Modular expansion zone cards Programmable relays and outputs Optional additional sounder circuits Optional additional programmable outputs

More information

ECC-50/100C. Emergency Command Center

ECC-50/100C. Emergency Command Center ECC-50/100C Emergency Command Center Canadian DF-60815:B Emergency Communications General Fire-lite s ECC-50/100C is a multipurpose emergency voice evacuation panel for fire applications, mass notification

More information

Honeywell Power POWER TO RUN YOUR SYSTEM. Product Guide

Honeywell Power POWER TO RUN YOUR SYSTEM. Product Guide Honeywell Power POWER TO RUN YOUR SYSTEM Product Guide Introduction Honeywell (NYSE: HON) is dedicated to providing power supplies and related accessories for the Fire, Video, Security and Access Control

More information

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs ACM8 Series UL Listed Sub-Assembly Access Power Controllers Installation Guide Models Include: ACM8 - Eight (8) Fuse Protected Outputs ACM8CB - Eight (8) PTC Protected Outputs Rev. 042811 More than just

More information

AL800ULADA. NAC Power Extender. Installation Guide

AL800ULADA. NAC Power Extender. Installation Guide AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery

More information

Accessories. Desk Top Controls

Accessories. Desk Top Controls Accessories Desk Top Controls 15-2 15-1 15-3 15-2-3 DTMO-1 DTMA-1 Under Desk Top Mounting The SDC 15 series switch controls are mounted on the underside of a desk for remote door control. They may be connected

More information

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS ECC-50/100(E) Emergency Command Center DF-60734:A4 General Firelite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

Accessories DESK TOP CONTROLS MODELS SPECIFICATIONS MODELS SPECIFICATIONS UNDER DESK TOP MOUNTING MINI DESK TOP CONSOLE

Accessories DESK TOP CONTROLS MODELS SPECIFICATIONS MODELS SPECIFICATIONS UNDER DESK TOP MOUNTING MINI DESK TOP CONSOLE Accessories DESK TOP CONTROLS UNDER DESK TOP MOUNTING The SDC 15 Series Switch controls are mounted on the underside of a desk for remote door control. They may be connected to the REX input of an access

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 042010 Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).

More information

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING GENERAL The VEC 25/50 is a state-of-the-art, compact, stand-alone or slave Emergency Voice Evacuation Control. The VEC 25/50 is offered in a self-contained, cost-effective design and includes a 25 Watt,

More information

SAFEPATH Mass Notification System (SPMNS)

SAFEPATH Mass Notification System (SPMNS) Supersedes February 2016 SAFEPATH Mass Notification System (SPMNS) SP40S SPB-320 SPB-80/4 SPB-160 PS-8-LP SPMNS-MIC SP4Z-A/B Contents Page SPMNS.... 2-4 SPMNS-MIC...3 Expansion Options SAFEPATH 2-zone

More information

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel PROTECTOWIRE FireSystems Features Easily expandable Two supervised audible circuits Lamp and system trouble circuit test Ground fault detection Initiating device circuit (IDC) alarm test Monitors up to

More information

Security Professional Mobile Showroom. Product Training

Security Professional Mobile Showroom. Product Training Security Professional Mobile Showroom Product Training Benefits of the Showroom Benefits of the Security Professional Showroom Are: Bringing Full Line of Solutions to You Tours for you Technicians and

More information

Model 17A00 Expansion Enclosure

Model 17A00 Expansion Enclosure HOME AUTOMATION, INC. Model 17A00 Expansion Enclosure Installation Manual Document Number 17I00-1 Rev A March, 2002 Home Automation, Inc. Model 17A00 Expansion Enclosure Installation Manual Document Number

More information

ORENA BRAND CONVENTIONAL (ORENA Brand) CE

ORENA BRAND CONVENTIONAL (ORENA Brand) CE ORENA BRAND CONVENTIONAL (ORENA Brand) CE ODH02E 2 Zone Conventional Control Panel Zone Capacity: can be connected with 20 fire detectors and infinite manual call points Using environment: Temperature:

More information

PS914 Power Supply. 900-KL Keylock (optional) Page BB Battery Backup (optional) Page 3

PS914 Power Supply. 900-KL Keylock (optional) Page BB Battery Backup (optional) Page 3 F1! DANGER 44487056 These instructions cover the following parts: PS914 Power Supply Installation Instructions! DANGER: To avoid risk of electric shock, turn off A power before installing or servicing

More information

July 14, 1999 DF C-100.

July 14, 1999 DF C-100. www.firelite.com GENERAL The Fire Lite FIRE COMMAND 25/50 is a state-of-theart, compact, stand-alone or slave Emergency Voice Evacuation Control Panel (VECP). The FIRE COMMAND 25/50 is offered in a self-contained,

More information

RGM 75 B - C4P N Z Articulating Z Bracket for wire management

RGM 75 B - C4P N Z Articulating Z Bracket for wire management GEMII RGM75 SERIES 4 Door 75W Integrated Mercury Drawer Standard / etworked, Single or Dual Voltage UL/CUL Unified Power Listing Four Post Mounting Overview Solving the industry problem of how to use the

More information

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel ACC-25/50ZST Zoned System Voice with Telephone Evacuation Control Panel General The AUDIO COMMAND CENTER 25/50 Zone System with FireFighters Telephone (ACC-25/50ZST) is a state-of-the-art Emergency Voice

More information

DS7400Xi Addressable Control/ Communicator

DS7400Xi Addressable Control/ Communicator DS7400Xi Addressable Control/ Communicator DS7400Xi DS7400Xi-EXP 110VAC operation 220VAC operation Remotely Programmable WDSRP (Windows Detection Systems Remote Programming Software), allows the systems

More information

DS160/161 Request To Exit PIR sensors Installation Instructions

DS160/161 Request To Exit PIR sensors Installation Instructions DS160/161 Request To Exit PIR sensors Installation Instructions 1.0 Description The DS160/161 is a passive-infrared (PIR) detector designed for request to exit (REX) interior applications. It is UL Listed

More information

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev. ACM8 & ACM8CB Access Power Controllers Installation Guide Models Include: ACM8 ACM8E - Fused Outputs - Fused Outputs ACM8CBE ACM8CB - PTC Outputs - PTC Outputs Rev. 092503 Overview: These units convert

More information

Commercial and Light Industrial Fire Alarm Control Panel

Commercial and Light Industrial Fire Alarm Control Panel FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel Features Easily expandable. All new plug-in board design Two supervised audible circuits Lamp and system trouble circuit test Ground

More information

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-3 ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS Features: For use with doors or groups of doors that must interlock with each other to regulate control of accessing one area from another,

More information

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

DIVISION 28 ELECTRONIC SAFETY AND SECURITY 281300 - ACCESS CONTROL A. General DIVISION 28 ELECTRONIC SAFETY AND SECURITY At the beginning of the project, schedule a meeting with the Facilities Access/Maintenance Coordinator with questions and concerns.

More information

ECC-50/100(E) Emergency Command Center

ECC-50/100(E) Emergency Command Center ECC-50/100(E) Emergency Command Center DF-60734:A9 C-200 General Fire Lite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,

More information

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014 January 16, 2014 Release Control Panel 290a 1. Description The Viking VFR400 is a microprocessor based releasing control panel for use on preaction, deluge, Surefire, Firecycle multicycle sprinkler systems,

More information

DS160/DS161 Request To Exit PIR sensors Installation Instructions

DS160/DS161 Request To Exit PIR sensors Installation Instructions DS160/DS161 Request To Exit PIR sensors Installation Instructions 1.0 Description The DS160 is a Passive Infrared Detector (PIR) which is UL Listed as an Access Control Device under the UL 294 Standard.

More information

A. Drawings and general provisions of Contract, including General and Supplementary Conditions apply to work of this section.

A. Drawings and general provisions of Contract, including General and Supplementary Conditions apply to work of this section. SECTION 16770 PAGE 1 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions apply to work of this section. B. Division 16

More information

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906 s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones

More information

EntryCheck E70 Series

EntryCheck E70 Series EntryCheck E70 Series Standalone Electronic Locksets The EntryCheck E70 Series is an indoor/outdoor standalone electronic battery powered solution, providing controlled access for basic and multi-level

More information

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi (P/N 10-068) is a state-of-the-art true intelligent digital peer-topeer modular suppression control system. It is ideal for

More information

SECTION INTRUSION DETECTION

SECTION INTRUSION DETECTION (NOTE TO DESIGNER: These Specifications are basic minimum criteria to be met in preparing the final specifications for this section, which is the responsibility of the Designer.) SECTION 28 16 00 INTRUSION

More information

SECTION LOW VOLTAGE LIGHTING CONTROLS

SECTION LOW VOLTAGE LIGHTING CONTROLS SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

Q1000 Series exit Devices

Q1000 Series exit Devices 1 1000 Series exit Devices 1000 Series Exit devices and Trims are designed for new or retrofit installation into other manufacturers devices. Push Bar assembly s smooth and reduced projection minimizes

More information

5600 series. Low Energy Power Operator

5600 series. Low Energy Power Operator 5600 series Introduction The 5600 Series, a member of the POWERMATIC Family of Operators, offers functionality and control at an affordable price. Ideal for retrofit applications, the 5600 Series converts

More information

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM SECURITY ACCESS AND SURVEILLANCE SECTION 13850 VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM ADEMCO Group 165 Eileen Way Syosset, New York 11791 1-800-645-7568 SECTION 13850 DETECTION

More information

POWER TRANSFERS ACCESSORIES EAC. Manufacturer Product Product No. Product Description Item No.

POWER TRANSFERS ACCESSORIES EAC. Manufacturer Product Product No. Product Description Item No. POWER TRANSFERS 47 Keedex Cord K-DLA K-DLB Keedex 18 Flexible Cord; Product No. K-DLA; 1/4 flexible conduit; use door loops when you need to transfer electrical current from the door frame to the door;

More information

120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE.

120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE. 00000 (0) 00 PowerMatic Low Energy Power Operator Wiring Instructions 0 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE. REQUIREMENTS: U.L.

More information

TruPortal Wireless Locks Quick Reference

TruPortal Wireless Locks Quick Reference TruPortal Wireless Locks Quick Reference en-us Introduction This document describes how to connect the following wireless locks to TruPortal hardware: Schlage AD-400, which connects to TruPortal hardware

More information

SP40S-D. Kingfisher Company, inc. Features: Description:

SP40S-D. Kingfisher Company, inc. Features: Description: Kingfisher Company, inc. SP40S-D Features: Multi-use applications The system can function as an evacuation system, an emergency messaging system, and an employee notification system Fire code applications

More information

IGD.CO.UK

IGD.CO.UK APPLICATION DATA SHEET S p e c i f i c a t i o n 2 SO22 WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700+ D e t e c t o r Website: C o n t r o l P a n e l - Wall mounting or 19 Rack

More information

RELEASE DEVICE CONTROLS

RELEASE DEVICE CONTROLS RELEASE DEVICE CONTROLS RELEASE DEVICE MODEL C+ INSTALLATION MANUAL UL LISTED CANADIAN LISTED CSFM: 7300-48:00 GENERAL DESCRIPTION: MADE IN THE U.S.A. S/N: The LM0-C+ Release Device/Control Panel is a

More information

Securitron. Switching Power Supplies

Securitron. Switching Power Supplies Securitron Switching Power Supplies Securitron AccuPower Works Better for The Securitron commitment to excellence continues with our AccuPower Series of switching power supplies the latest addition to

More information

Sierra Series 900 Single & Dual Channel System. Instruction Manual

Sierra Series 900 Single & Dual Channel System. Instruction Manual Series 240/24 Instruction Manual Table of Contents Sierra Series 900 Single & Dual Channel System Instruction Manual Part Number IM-90-07/05 Revision D. 5 Harris Court, Building L Monterey, CA 93940 (83)

More information

5900 SERIES Low Energy Power Operator

5900 SERIES Low Energy Power Operator Low Energy Power Operator introduction The Norton 5900 Series is a full-featured, extremely quiet, low energy door operator designed for moderate to high traffic doors. This cost-effective operator is

More information

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X AL1002ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 071508X Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).

More information

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes

More information

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

ACM4 Series UL Listed Sub-Assembly Access Power Controllers ACM4 Series UL Listed Sub-Assembly Access Power Controllers Installation Guide Models Include: ACM4 - Four (4) Fuse Protected Outputs ACM4CB - Four (4) PTC Protected Outputs Rev. 051311 More than just

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D2 MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D2 GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL RELEASE DEVICES MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL The LiftMaster Fire Control (LM21-AFC) Release Device/Control Panel is UL/CUL listed normally energized fail-safe device incorporating

More information

PDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual

PDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual INSTALLATION PDD-8PCI PDD-8PCI Power Distribution Board With Supervised Interface Installation and Specifications Manual Details The PDD-8PCI board is a power distribution/control interface. This board

More information

For Complete Fire and Gas Solutions

For Complete Fire and Gas Solutions Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable

More information

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM SECURITY ACCESS AND SURVEILLANCE SECTION 13850 VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM ADEMCO Group 165 Eileen Way Syosset, New York 11791 1-800-645-7568 SECTION 13850 DETECTION

More information