1 Product Overview The HF9101-V1 is an electronic thermostat designed to give energy-efficient frost protection to pipe work where thermal insulation alone cannot protect pipes from freezing or being damaged by ice. The unit controls heater tape or Infra-Red (IR) quartz lamps. Features & Benefits Simple setup & installation Includes sensor Temperature Trip Point 4 C 1 C Hysteresis Maintenance free IP65 Ingress protection Current capacity 25A Max. Sensor & load fault detection Power & Status LED indicators BMS Load On output Product Setup Connect the mains supply and load to the controller using the appropriate cable. If connecting the BMS output, ensure appropriate IP rated gland is used. Operation When the mains supply is switched on the Power LED will illuminate and the microprocessor with run a check to ensure the sensor and load are working correctly. When the ambient temperature drops below the pre-set temperature of 4 C, the load output relay energises the status LED will illuminate and BMS output is on. When the ambient temperature is equal to or greater than the set point temperature, the load output switches off and the output LED and BMS output will be off. Alarms The unit can detect an open-circuit or short-circuit temperature sensor. In addition to this, the unit tests the output immediately at power up and every four hours thereafter. The output will switch off momentarily during a test. Normal operation will resume once the test is complete. Alarm relay fitted (see specifications, BMS).
2 The unit can detect the following faults: 1) Open-circuit/short-circuit temperature sensor. 2) Open-circuit load. In all above cases, the alarm LED will flash. For the temperature sensor alarm the rate is approximately one tenth of a second and for the load alarm the rate is approximately half a second. BMS is set as a load run indicator only. Fusing It is recommended to use standard F-type quick-blow fuse or circuit breaker (MCB type D) rated at 30A Max. for in line unit protection. (See the SRA Datasheet for further information). CE Marking This product family carries a CE marking and are RoHS compliant. For further information contact our sales desk. (See the Declaration of Conformity). Recommendation Other documents are available on request, which may be appropriate for your applications. Code Identity Description X10255 SRA Safety requirements - addressing the Low Voltage Directive (LVD) including:- Thermal data/cooling; Live parts warning & Earth requirements; Fusing recommendations. AP02/4 COS UAL Conditions of sale Note: It is recommended that installation and maintenance of this equipment should be done with reference to the current edition of the I.E.E. Wiring Regulations (BS7671) by suitably qualified/trained personnel. The regulations contain important requirements regarding safety of electrical equipment. (For International Standards refer to I.E.C. Directive I.E.C. 950).
3 Technical Specification (all models unless otherwise stated) Supply Voltage 230V AC +/- 10% Supply Frequency 50Hz Power Switching Capacity 25A Max. Load Current 25A Max. Temperature Set Point (Fixed) 4 C Temperature Accuracy 1 C Current Consumption 16mA Power & Output LED Indicators (see ALARMS section for details) Supply Terminal Connections 0.2 to 6mm² Rising clamp Ambient Operating Temperature -20ºC to +40ºC Ingress Protection (IP) Rating IP65 Built in Sensor Encapsulated 10kΩ NTC thermistor probe Sensor Monitoring HF9101: open or short circuit - unit shuts down and alarms Sensor Terminal Connections 0.1 to 1.5mm² Rising clamp Building Management System (BMS) Alarm relay normally energised when load is ON Enclosure Dimensions 130(W) x130(l) x75((h) mm Fixing Hole & Centre Dimensions 4x4.8mm Ø holes on fixing centres 115(W) x115(l) mm Contact Information T&D (Gateshead) T&D (Bristol) Gear House Units 9 & 10 Saltmeadows Road Birchills Trading Estate Gateshead Emery Road NE8 3AH Brislington Bristol BS4 5PF Phone: Phone: Northernsales@thorneandderrick.co.uk Southernsales@thorneandderrick.co.uk
4 Installation Mounting NOTE: If mounted in the vertical plane the glands MUST be as shown to ensure IP rating.
5 Installation Wiring Diagram shows the wiring connections and cable entry NOTE: The glands (not supplied except sensor gland) MUST be tightened to ensure the IP rating. The set point control dial is also shown.
RE-PR3-E-27 3-Phase Panel Mount 27kW
Page 1 of 6 RE-PR3-E-27 3-Phase Panel Mount 27kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting
More informationElectrisaver User and Installation Instructions
Electrisaver User and Installation Instructions The Electrisaver push button boost timer can be used to control immersion elements and other electrical appliances up to 3kW or as an override/extension
More informationMODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL
TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External
More informationCondensate FreeFlo. Condensate FreeFlo. Homeowner Guide. Installation Guide. Indicator Light. Running Costs. Product Overview
Condensate FreeFlo Model: CF301 To protect external condensate pipe runs of up to 3m 06490097001 IssA Invensys Controls Sales: +44 (0) 845 / 130 5522 Technical: +44 (0) 845 / 130 7722 Fax: +44 (0) 845
More informationSingle Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual
We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More informationQAF63.2-J QAF63.6-J. Frost detectors. for use on the air side
s Frost detectors for use on the air side QAF63.2-J QAF63.6-J Active capillary tube sensor for acquiring the lowest temperature within a range of 0 15 C Operating voltage AC 24 V Signal output DC 0...10
More informationMODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT
TRACON MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT TABLE OF CONTENTS GPT 130 Overview... 2 Installation... 3 Power Source and Load Connection... 4 Temperature Sensor Installation... 5 Panel
More informationPipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual
MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...
More informationDual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual
We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More informationSPECIFICATION GUIDELINE FROST PROTECTION FOR PIPES. Tender Specification. Engineering Specification for Pipe Frost Protection. Contents.
Tender Specification Package #: Trace Heating Engineering Specification for Pipe Frost Protection Contents Y24 Trace heating 2 Appendix A Schematics & Drawings 8 Prepared by: Authorised by: Issued
More informationNXM2G Installation and Operating Manual
NXM2G-1001 MARCH 26, 2014 NXM2G Installation and Operating Manual (-1 UL version shown) 40VG This manual must be affixed on or adjacent to the boiler or kept with boiler operating manual or other information.
More informationFeatures. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign
Features DATASHEET Connects to multiple sensing instruments One/Two Channel Device Bright solid state LED Alarm Display Audible Alert (internal and external) High reliability, fully dual redundant alarm
More informationInstructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes
Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes 50-120 1 General The heat exchanger control system is a control system for 380 W step motors
More informationINSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06
INSTRUCTION MANUAL 8100 & 8200 Monitor Manual Issue 06 ** This page is intentionally left blank ** Table of Contents 1 Introduction... 4 1.1 Manual Conventions... 4 1.2 Version 4 PCBA's... 4 1.3 Product
More informationACS-30-EU-EMDR- 10-MOD
ACS-30-EU-EMDR- 10-MOD MULTI-APPLICATION HEAT TRACING CONTROL AND MONITORING IN COMMERCIAL AND RESIDENTIAL BUILDINGS ROOF & GUTTER DE-ICING SENSOR MODULE TECHNICAL INFORMATION DESCRIPTION The nvent RAYCHEM
More information10yr O2NE & Safe-Ox. User Manual
Analox Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK T: +44 (0)1642 711400 F: +44 (0)1642 713900 W: www.analox.net E: info@analox.net This support line is closed on UK public
More information5230IG. Thermotouch 3.2aP Wireless Heating Thermostat
5230 Thermotouch 3.2aP Wireless Heating Thermostat 1 Introduction Thermotouch 3.2aP wireless thermostat Thermotouch 3.2aP is a wireless thermostat, which is designed for electric floor heating systems
More informationCRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions
6810850/1 IM-P681-07 ST Issue 1 CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
More informationThe next generation thermometer from the global leader
akm oti/wti Remote mount thermometers The next generation thermometer from the global leader Accomplish the most demanding control and alarm configurations Reduce failure costs with reliable AKM bellows
More information18W Round LED Wall/Ceiling Light with Microwave Sensor
18W Round LED Wall/Ceiling Light with Microwave Sensor Model: LEDMR18WHMS Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further
More informationFrost Protection Thermostat
1 203 Frost Protection Thermostat Electromechanical thermal reset limit thermostat RAK-TW.5..H RAK-TW.5..H.. Use Monitoring of frost protection temperature, with single-pole changeover microswitch Switching
More informationINSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS Please read these instructions thoroughly before installation and ensure they are passed on to the end-user 1 1.0
More informationDipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 505 Grünberg Tel.: 00 807-0 Fax: 00 807-259 Insulation monitoring device for unearthed AC/DC systems (IT systems for the supply of operating theatre
More informationInstallation and Wiring Instructions
Powerline (TDF) Installation and Wiring Instructions TDF32014 TDF38014 TDF42014 TDF48014 TDF38034 TDF42034 TDF48034 TDF52034 TDF52036 TDF60034 TDF60036 PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING
More informationSmoke Vent Control Panel PCB4 V4 Installation Manual
Smoke Vent Control Panel PCB4 V4 Installation Manual 10A PCB4 Control Panel Do Not Remove From PCB4 Control Panel www.besafedirect.com Page 1 Contents Page 3) Important Regulations, Safety, Maintenance,
More informationUser manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc
User manual Explosion-safe window air conditioning system Type series AR-054 II 3 G Ex ic nac h IIC T3 Gc 1. Safety Instructions The window air conditioning series AR-054 is an explosion-safe product suitable
More informationLC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV
LC1 & 2 Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV ZIRCONLC1 One Zone Conventional Fire Panel ZIRCONLC2 Two Zone Conventional Fire Panel Compliant with EN54-2:1998 & EN54-4:1998
More informationQAF64.2-J QAF64.6-J. Frost detector. for use on the air side
s Frost detector for use on the air side QAF64.2-J QAF64.6-J With active capillary tube sensing element for acquiring the lowest temperature within a range of 0 15 C With startup function Operating voltage
More informationISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)
ISOMETER IR425 Insulation monitoring device for unearthed AC/DC control circuits (IT systems) IR425-D4_D00039_04_D_XXEN/05.2017 ISOMETER IR425 Insulation monitoring device for unearthed AC/DC control circuits
More information, ,
796-2028, 796-2021, 796-2025 Batten mount PIR detectors Overview This series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control
More informationElectronic timeswitch
Electronic timeswitch RWB1007 To control combination boilers and single zone applications together with the appropriate thermostat. Easy-to-read backlit display Time programming 7-day 2/3 ON/OFFs Advance
More informationPIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features
Product Guide PIR/INT & PIR/INT-D Batten mount PIR detectors Overview The PIR/INT & PIR/INT-D miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional
More informationLC3000 Level Controller Installation and Maintenance Instructions
4025550/12 IM-P402-36 AB Issue 12 LC3000 Level Controller Installation and Maintenance Instructions 1. General safety information LC3000 NORM ALARM TEST 2. General product information 3. Installation 4.
More informationLEAKSTOPPER RANGE Multizone water leak detection systems
LEAKSTOPPER RANGE Multizone water leak detection systems WHAT DOES THE PRODUCT DO? The LeakStopper detects water leaks and instantly triggers an alarm to warn you. It is capable of monitoring between 2
More informationMain switch current K: with main switch (optional)
Control Boxes, Boxes and Other Components BXM(D)81 Series Explosion-proof Illumination (Power) Boxes (Ex d IIB) Explosion protection to -CENELEC -IEC Can be used in Zone 1 and Zone 2 in Zone 21 and Zone
More informationDOL 31 Speed Controller Technical User Guide
Technical User Guide For other language variants of this document we refer to your local dealer or http://docs.skov.com/1158. Available from April 2016. 612061 2016.09.20 Technical User Guide Program
More informationSemi flush-mount room thermostats
s 1 440 RDD310/EH RDE410/EH Semi flush-mount room thermostats for control of electric floor heating systems and for hydronic zone control systems RDD310/EH RDE410/EH Key features of both types of thermostats:
More informationElectronic 7 Installation Instructions
Electronic 7 Installation Instructions The Horstmann Electronic 7 is an advanced water heating control, which can be programmed to take advantage of cheap night-rate electricity, so that there is a tank
More informationPopcorn Warmer Cabinet
Popcorn Warmer Cabinet Copyright July 2016 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or
More information12W Round LED Wall/Ceiling Light with Microwave Sensor
12W Round LED Wall/Ceiling Light with Microwave Sensor Model: LEDSR12WHMS Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further
More informationExcellence in Level Measurement
Technical Data Sheet No. Novaflo 2000 'Fail-Safe' Level Alarm System Excellence in Level Measurement Afriso Eurogauge Ltd Imberhorne Lane, East Grinstead West Sussex. RH19 1RF Tel: 01342 323641 Fax: 01342
More informationMAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL
MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL Contents IMPORTANT... 3 General Description... 4 General Operation... 4 Changing Factory Settings... 4 Alarm Type... 4 Check Interval...
More informationISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15
with coupling device AGH675-7 and AGH675-7MV15 Device combination for insulation monitoring in unearthed AC, AC/DC and DC power systems (IT systems) IRDH275BM-7_D00123_03_D_XXEN/01.2017 with coupling device
More informationInductive slot sensor
0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output
More informationDESIGN GUIDELINES. THERMAL building SOLUTIONS
DESIGN GUIDELINES XL-Trace LSZH Self-Regulating Heating Cables for Pipe Freeze Protection Systems THERMAL building SOLUTIONS WWW.PENTAIRTHERMAL.COM Pipe Freeze protection system overview SBS Control Panel
More information14300 MAINS SEPARATOR ALARM MANUAL
Conder Environmental Solutions 14300 MAINS SEPARATOR ALARM MANUAL Separator and Alarm provided by: Alarm Installation, Commissioning & Servicing Support Please contact: www.envirotank.com.au www.envirotank.co.nz
More informationHeated Display Merchandiser. Instruction Manual. Models: GC875-A / GC876-A / GC877-A
Heated Display Merchandiser Instruction Manual Models: GC875-A / GC876-A / GC877-A Safety Tips Position on a flat, stable surface. A service agent/qualified technician should carry out installation and
More informationDoor Release Power Supply
www.protectingpeople.co.uk Door Release Power Supply Engineer / Installation Manual Document: VI55.1 Protecting People Printed : 04/03/2004-1 - Ventcroft Ltd Door Release Power Supply Engineer / Installation
More informationSmoke Fire Damper Interface (230V)
Always READ this document BEFORE INSTALLATION. Please Retain for future reference. This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product
More informationET10 Series Stand-alone LCD Fan Coil Thermostat
ET10 Series Stand-alone LCD Fan Coil Thermostat Features Modern Appearance Stylish Rotary dial and buttons Large LCD with backlight Separate power supply unit with high performance relay outputs Retention
More informationKHM800 Professional 800w haze machine
KHM800 Professional 800w haze machine M A N U A L V E R S I O N 2. 0 0 6-1 1-1 2 Due to continuous product development, please ensure that you have downloaded the latest instruction manual for this product
More informationRoom thermostats with LCD RDD100..
s 1 420 Room thermostats with LCD RDD100.. for heating systems Roomom temperature control Comfort, Economy and Protection mode 2-position control with On/Off control output Adjustable commissioning and
More informationLabkotec Ice Detector
Labkotec Ice Detector LID 3300IP Level and flow know-how since 1964 Benefits of using Ice Detector Stops wind turbine to prevent icethrow Safety first of all! Safety device Authorities / construction licence
More informationFH3HT. 3Kw HIGH TEMPERATURE ELECTRIC FAN HEATER PRODUCT MANUAL
FH3HT 3Kw HIGH TEMPERATURE ELECTRIC FAN HEATER PRODUCT MANUAL 1 These instructions should be read by: The specifying engineer. The installation engineer. The user. The service engineer. WARNINGS Failure
More informationTEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a
TEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a DESCRIPTION AND APPLICATION These resistance-type sensors are intended for contact temperature measurement of gaseous substances. The sensor consists of a metal
More informationJDDT1 - Single Stage Digital Thermostat
JDDT1 - Single Stage Digital Thermostat CAUTION NOTICE: The thermostat must be installed by authorized professionals. It should be located in a place free of vibrations, impacts, and corrosive gases. SET
More informationQAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products
1 821 1821P01 Frost sensors for use on the air side Active capillary tube sensor for measuring the lowest temperature within a range of 0 15 C Operating voltage AC 24 V Signal output DC 0...10 V Use On
More informationFHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P
FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P 1 of 13 These instructions should be read by: The specifying engineer. The installation engineer. The user. The service engineer. WARNINGS Failure
More informationthe next generation thermometer from the global leader
OTIWTI Remote mount thermometers (AKM) the next generation thermometer from the global leader Six switch capability, sequentially independent, with adjustable hysteresis Reduce failure costs with reliable
More informationRoom thermostat with 24-hour time switch and large LCD
Room thermostat with 24-hour time switch and large LCD RDJ100 Programmable, for heating systems Operating modes: Automatic, Comfort, Energy saving, and Frost protection Large LCD display Battery powered:
More information230v Dial Thermostat Instruction Manual
230v Dial Thermostat Instruction Manual Contents Box contents: 230v Dial Thermostat Instruction Manual Instruction Manual Fixing screws JGSTAT1 Instruction manual: Box contents Introduction Product compliance
More informationOperation and Maintenance Manual
(FKER Series) Repeater Panel (FKER, FKER, FKER8) Operation and Maintenance Manual Man-9EL Issue June Index Section Page. Introduction.... Safety and mounting.... Technical specification.... Control panel
More informationEBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features
Product Guide EBMPIR-MB Batten mount PIR detectors Overview The EBMPIR-MB series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual
More informationGasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.
Gasflag Single Channel Control Panel Alarm Only Apparatus Installation, operating and maintenance instructions, M07225 Issue 2 1/07/05 Crowcon Detection Instruments Ltd 2 Blacklands Way Abingdon Business
More informationLPC3BSP65 & LPC3BDP65
Product Guide LPC3BSP65 & LPC3BDP65 Batten mount PIR detectors Overview The LPC3B series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional
More informationFrost Units for air temperature monitoring
284 284P0 Frost Units for air temperature monitoring QAF8... Robust aluminium die-cast housing Responds to temperature change sensed over any 30 cm length of capillary Small switching differential Good
More informationISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)
Insulation monitoring device for unearthed AC/DC control circuits (IT systems) TDB103005en/05.2013 Insulation monitoring device for unearthed AC/DC control circuits (IT systems) Product description The
More informationDual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual
We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More informationOperating Instructions
Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2SW ENGLAND Tel: +44(0)191 5863511 www.seaward.co.uk sales@seaward.co.uk service@seaward.co.uk Part Number 347A550 Revision 1 2006 Seaward
More informationTraining, Assessment, Consultants for Hazardous & Industrial Areas
Training, Assessment, Consultants for Hazardous & Industrial Areas EPIT provides specialist training, assessment and consultancy services for engineers working in hazardous and industrial environments.
More informationIT system floor-standing distribution
IT system floor-standing distribution cabinet series -IPS-F/EDS for supplying power to medical locations in accordance with IEC 60364-7-710 and featuring a built-in insulation fault location system IT
More informationWireless room thermostat with LCD
s 1 424 RDD100.1RF RCR100RF Wireless room thermostat with LCD for heating systems RDD100.1RFS Roomom temperature control Comfort, Economy and Protection mode 2-position control with On/Off control output
More informationInstructions for the fan motor control system, SILVER C
Instructions for the fan motor control system, SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units. The motor control system is
More informationINSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations
INSTRUCTION MANUAL D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations synchronization requirements of UL1971 & UL1638 / CAN/ULCS526. 2.2 NEC & CEC Class / Division Ratings for US / Canada
More informationUV Flame Supervision System
7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running
More informationInstallation, operating and servicing instructions
English 57-115 - 144-1 - 259 Installation, operating and servicing instructions ITALIA EN 1 ITALIA English INDEX WARnINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Importants notes
More informationInstruction FH-CWP Thermostat
Instruction FH-CWP Thermostat Index Instruction FH-CWP Thermostat 1. Functional Overview.......................... 3 2. Mounting..................................... 4 3. Installation....................................
More informationMC 31 Speed Controller Technical User Guide Code no GB
Technical User Guide Code no. 99-97-0968 GB Ausgabe: 0 /201 Technical User Guide Program Version The product described in this manual holds software. This manual corresponds to: Software version 1.3 It
More informationGM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /
3 GM20 Digital Ground Continuity Relay For AC Systems Technical Bulletin NAE03230 / 0.20 GM20 Ground continuity monitor For AC systems Description The GM20 monitors the loop resistance of ground conductors
More informationFire Damper Interface (230V)
Always READ this document BEFORE INSTALLATION. Please Retain for future reference. This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product
More informationCoziStat. 1. Introduction and Brief Description COZISTAT INSTALLATION I NSTRUCTIONS &OPERATING MANUAL
COZISTAT INSTALLATION I NSTRUCTIONS &OPERATING MANUAL CoziStat 1. Introduction and Brief Description The CoziStat is an easy-to-use, programmable thermostat with digital display. CoziStat can be used with
More informationSmoke Damper Interface (230V)
Always READ this document BEFORE INSTALLATION. Please Retain for future reference. This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product
More informationSnifter ATEX22 VERSION. User Manual. Distributor
Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5
More informationEUROSTER 1100E USER MANUAL 1 EUROSTER 1100E
EUROSTER 1100E USER MANUAL 1 EUROSTER 1100E Congratulations on choosing our thermostatic controller EUROSTER. It is a technically advanced product which will serve you and your family for years bringing
More informationInstructions for the fan motor control system with integrated wiring terminals SILVER C
Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.
More informationSigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009
Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual Man-1048 Issue 05 October 2009 CONTENTS Contents... Page Safety & Installation...2 Installation - continued...3
More informationLINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems
LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,
More informationHEA USER MANUAL. 1 Version: 22. June 2010
HEA USER MANUAL 1 Version: 22. June 2010 INDEX PAGE RECEIPT OF EQUIPMENT....... 3 LIFTING AND HANDLING.... 3 INSTALLATION INSTRUCTIONS...... 4 MAINTENANCE INSTRUCTIONS... 5 CONTROL OF INSULATION... 6 THERMOSTATS.
More informationFreeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual
MANUAL We manage heat Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual Environmental Technology, Inc. 1850 N Sheridan Street South Bend, Indiana 46628 http://www.networketi.com/
More informationWIO200 Water In Oil measuring instrument
WIO200 Water In Oil measuring instrument You have made the right decision by choosing a measuring instrument from PAJ Systemteknik. Many customers buy our high standard products every year. There are at
More informationCat. No TPT44. Installation & Operating Instructions
Underfloor Heating Controller Cat. No TPT44 Installation & Operating Instructions 1 General The ProgramaSTAT TPT44 combines the elements of timeswitch and room thermostat in a single compact, economical
More informationSaffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.
Saffire+ 8-12 User & Installation Manual IMPORTANT This manual should be left with the panel after installation. We reserve the right to change product specifications without prior notice. Copyright VRC
More informationhighline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10
highline WINDOW CONTROLS INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM SVCS-1 * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10 CERTIFICATE OF COMPLIANCE SVCS-1 We the undersigned
More informationLonworks Damper Interface Catalogue
Lonworks Damper Interface catalogue Release: 1.9 AUGUST 2017 Lonworks Damper Interface Catalogue Two Position, Three Position & Hot Smoke Fire Damper Interface This product forms part of a life safety
More informationINSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres
INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG05D-SIL is a flameproof beacon which is certified
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT
More informationLAE10 LFE10. Use. Series 02
ISO 00 Flame Safeguards 7 7 LAE L Series 02 Supplementary data sheets 772 and 773 Flame safeguards for burners with intermittent operation. For safety reasons - self-test of flame supervision circuit,
More informationTHERMOMAX COLTREC RCX 100 MICROPROCESSOR REFRIGERATION CONTROL SYSTEM ENGLISH.
THERMOMAX COLTREC RCX 100 MICROPROCESSOR REFRIGERATION CONTROL SYSTEM ENGLISH www.thermomax-group.com CONTENTS SECTION 1 - INTRODUCTION... 2 SECTION 2 - INSTALLATION... 3 2.1 - RCX 100 UNIT... 4 2.2 -
More informationAnalox Safe-Ox/Safe-Ox He
Analox Safe-Ox/Safe-Ox He User Manual Analox Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK T: +44 (0)1642 711400 F: +44 (0)1642 713900 W: www.analox.net E: info@analox.net
More information