Input/Output Modules Data Sheet
|
|
- Percival Thompson
- 6 years ago
- Views:
Transcription
1 Input/Output Modules Data Sheet The wide range of input and output modules available from NOTIFIER delivers exceptional flexibility to a NOTIFIER fire detection and alarm system. Using these modules enables integration with a host of other building management and emergency systems, including access control systems, lifts, fire shutters and emergency lighting. Features Analogue addressable communications Builtin type identification automatically identifies these devices to the control panel (not MX) Stable communication technique with high noise immunity Rotary DECADE to address switches (not MX) Common mounting options including Surface Mount, Panel Mount and DIN Rail Mount. Tricolour LED s Powered directly by wire loop. No additional power required Plugin terminal connections for ease of field wiring Approved to CEA GEI AND CEA GEI 4 CPD approval to EN54 and EN54, LPCB and VdS Installation The M series modules can be mounted either surface, panel mounted in other equipment housings or DIN rail mounted in other equipment housings. Surface mounting is achieved by using the MESMB surface mount box which accepts a single module. This box has a frosted plastic lid with viewing windows for the product identification label, LED s and address switches. This document is not intended to be used for installation purposes. Every care has been taken in the preparation of this document but no liability can be accepted for the use of the information therein. Design features may be changed or amended without prior notice. For more information, contact: NOTIFIER. Charles Avenue, Burgess Hill, West Sussex, RH5 UF. United Kingdom Phone: 44 () Fax: 44 () Page of 53_4 ISO Design, Manufacture and Supply to Quality Management Systems Certified to ISO:4
2 M Single input module The M series modules are designed for use with any NOTIFIER protocol fire alarm control panel and include selectable loop isolation in every device. The M module monitors a single input device circuit of normally open dry contact alarm activation devices. These modules use one of available module addresses on a loop and respond to regular polls from the control panel reporting its type and the status (open/normal/short) of its supervised device circuit. M Single input module Weight: mm mm 3 mm g Current Consumption Without communication Communication every 5 sec. with LED blink enabled. 3 4 VDC; 5 4 VDC Maximum Alarm Current: 5 4 VDC (per LED with LED enabled) Operating Voltage: 5 to 3 VDC peak C to 6 C % to 5%, noncondensing mm MEDIN MESMB 3mm mm MEPMB 3mm 4mm 34mm Page of 53_4
3 Non Addressable Zone Monitor Module MCZR The MCZR nonaddressable zone monitor module allows a zone of nonaddressable detectors to communicate with a Notifier analogue addressable system. As a result existing nonaddressable loops can be integrated into a Notifier addressable system The module monitors a zone of twowire nonaddressable smoke detectors. Each MCZR uses one of available module addresses on a loop. The nonaddressable zone can be powered from the analogue communication line or from an external power supply. Where the nonaddressable zone is powered from an external power supply, the communication line is fully isolated from the nonaddressable zone and from the power supply. This MCZR nonaddressable Zone Monitor module fits into MESMB, MEDIN or MEPMB. These may then be installed in a Rack Assembly using Notifier Rack mounting adapters. Non Addressable Zone Monitor Module MCZR Weight: 3 mm 3 mm 3 mm g Operating Voltage Range: to.5vdc Max. Standby Current: μa maximum (conventional zone connected to external supply) LED Current 4Vdc Green: 4Vdc 4Vdc End of Line Resistor Value: 3.k Temperature Range: Humidity: C to 6 C 5% to 5% relative humidity (noncondensing) 3mm MEDIN MESMB 3mm 3mm MEPMB 3mm 4mm 34mm Page 3 of 53_4
4 M Single output module The M series modules are designed for use with any NOTIFIER protocol fire alarm control panel and include selectable loop isolation in every device. The M control module provides a monitored single output circuit for use with polarised loads (sounder circuit) which requires a suitable power source (Vdc 3Vdc) for the connected load. Alternatively the same device may be placed in to an unsupervised mode which can then be used to control any switched load up to 3Vdc. In addition the M4 and the M4DIN provide two ( x N.O. x N.C.) 5Vac (nominal 3Vac), 5Amp contact outputs. The M4 is provided complete with a surface mounting back box and the M 4DIN is supplied in a DIN rail mounting package. These modules use one of available module addresses on a loop and respond to regular polls from the control panel reporting its type and the status (open/normal/short) of its supervised device circuit. M single output module mm mm 3 mm Weight: M g M4 g M4DIN 5g Current Consumption (Without communication) M 3 4 VDC M4 & M4DIN 5 4 VDC Current Consumption (Communication every 5 sec. with LED blink enabled) M 5 4 VDC M4 & M4DIN VDC Maximum Alarm Current: Operating Voltage: 5 4 VDC (per LED with LED enabled) 5 to 3 VDC peak C to 6 C % to 5%, noncondensing M mm M4DIN M4 5mm 3mm 3mm mm 4mm 6mm 4mm 34mm Page 4 of 53_4
5 M Dual Input Module The M series modules are designed for use with any NOTIFIER protocol fire alarm control panel and include selectable loop isolation in every device. The M dual monitor module provides two supervised input device circuits of normally open dry contact alarm activation devices. The M module uses two addresses of available module addresses on a loop and responds to regular polls from the control panel reporting its type and the status (open/normal/short) of their supervised device circuits. M Dual Input Module Weight: mm mm 3 mm g Current Consumption Without communication Communication every 5 sec. with LED blink enabled VDC; 6 4 VDC Maximum Alarm Current: 5 4 VDC (per LED with LED enabled) Operating Voltage: 5 to 3 VDC peak C to 6 C % to 5%, noncondensing mm MEDIN MESMB 3mm mm MEPMB 3mm 4mm 34mm Page 5 of 53_4
6 M Dual Input Module with Output The M series modules are designed for use with any NOTIFIER protocol fire alarm control panel and include selectable loop isolation in every device. The M dual input, single relay output module, as well as providing two supervised inputs also provides a single change over relay output rated at The M uses three addresses of available module addresses on a loop and responds to regular polls from the control panel reporting its type and the status (open/normal/short) of their supervised device circuits. M Dual Input Module with Output Weight: mm mm 3 mm g Current Consumption Without communication Communication every 5 sec. with LED blink enabled. Maximum Alarm Current: Operating Voltage: 34 4 VDC; 66 4 VDC 5 4 VDC (per LED with LED enabled) 5 to 3 VDC peak C to 6 C % to 5%, noncondensing mm MEDIN MESMB 3mm mm MEPMB 3mm 4mm 34mm Page 6 of 53_4
7 Way Output Module CMXRM Each output is individually addressed and controlled by the control equipment. This provides a cost effective, compact solution for installations requiring multiple switching and / or monitoring at a single location. Each output consists of a form C (change over) relay contact providing both normally open and normally closed contacts rated A at 3Vdc. Each module card utilises up to consecutive addresses with the base address being set by DIP switch although any of the addresses may be individually disabled allowing the use of this address by other modules on that loop. Way Output Module CMXRM 33 mm mm 3 mm Current Consumption.mA with communication and LED blink enabled LED Current, 4Vdc (LED on) per module The modules are supplied as a P.C.B. allowing installation in to other equipment housings such as control cabinets. 5 x 3.5mm mounting holes provide suitable secure mounting for the P.C.B s. Each module occupies a single Notifier Loop Module address with the first address being set by DIP switch SW and subsequent address being base address n up to a maximium of. Individual modules may be disabled via a second DIP switch SW such that any module address in the range can be used for other module addresses on the loop. Connection Detail C to 55 C % to 3%, noncondensing Mounting Detail Page of 53_4
8 Way Input Module MMXM Each input is individually addressed and controlled by the control equipment. This provides a cost effective, compact solution for installations requiring multiple switching and / or monitoring at a single location. Inputs may be configured to monitor for open circuit, short circuit and active (fire) conditions. Each module card utilises up to consecutive addresses with the base address being set by DIP switch although any of the addresses may be individually disabled allowing the use of this address by other modules on that loop. Way Input Module MMXM 33 mm mm 3 mm Current Consumption.mA with communication and LED blink enabled LED Current, 4Vdc (LED on) per module The modules are supplied as a P.C.B. allowing installation in to other equipment housings such as control cabinets. 5 x 3.5mm mounting holes provide suitable secure mounting for the P.C.B s. Each module occupies a single Notifier Loop Module address with the first address being set by DIP switch SW and subsequent address being base address n up to a maximium of. Individual modules may be disabled via a second DIP switch SW such that any module address in the range can be used for other module addresses on the loop. Connection Detail C to 55 C % to 3%, noncondensing Mounting Detail Page of 53_4
9 5 Way Input and 5 Way Output Module MCX55 Each input and output are individually addressed and controlled by the control equipment and provide a cost effective, compact solution for installations requiring multiple switching and / or monitoring at a single location. Inputs may be configured to monitor for open circuit, short circuit and active (fire) conditions. Each output consists of a form C (change over) relay contact providing both normally open and normally closed contacts rated A at 3Vdc. Each module card utilises up to consecutive addresses with the base address being set by DIP switch although any of the addresses may be individually disabled allowing the use of this address by other modules on that loop. M Dual Input Module with Output 33 mm mm 3 mm Current Consumption.mA with communication and LED blink enabled LED Current, 4Vdc (LED on) per module The modules are supplied as a P.C.B. allowing installation in to other equipment housings such as control cabinets. 5 x 3.5mm mounting holes provide suitable secure mounting for the P.C.B s as indicated overleaf. Each module occupies a single Notifier Loop Module address with the first address being set by DIP switch SW and subsequent address being base address n up to a maximium of. Individual modules may be disabled via a second DIP switch SW such that any module address in the range can be used for other module addresses on the loop. Connection Detail C to 55 C % to 3%, noncondensing Mounting Detail Page of 53_4
10 Connection Detail M / M Connection Detail Notes: (See notes ) M / M A B If short circuit isolation is not required, loop output should be wired to terminal 5 and not. Terminal 5 is internally connected to terminal 4. The dashed line circuit connected to terminals and should only be used with the M. There are no connections to these terminals on the M. 3 Provided the control panel is compatible, short circuit monitoring of the input circuit may be possible. An K Ohm resistor should be wired in series with each device switch being monitored A x B x C 4KΩ 4KΩ See Note M Connection Detail (See notes ) M A B Notes: If short circuit isolation is not required, loop output should be wired to terminal 5 and not. Terminal 5 is internally connected to terminal 4. Provided the control panel is compatible, short circuit fault monitoring of the input circuit may be possible. An K Ohm resistor should be wired in series with each device switch being monitored A x B x C 4KΩ 4KΩ NC C NO Relay Contact Rating: 3VDC, A resistive load MX Connection Detail MX Page of 53_4
11 Connection Detail EOL (See notes ) External Power Supply Maximum 3VDC, Minimum VDC See Note 3 M Supervised Connection Detail M 6 See Note 5 and Table 3 A x B x C 6 A B Table : EOL Monitoring Options Mode Switch A Switch B EOL Device Load Position Position Std 4KΩ Resistor See Note 4 VdS Polarised 4Ω See Note 5 RLY N/A Unsupervised Notes: If short circuit isolation is not required, loop output should be wired to terminal 5 and not. Terminal 5 is internally connected to terminal 4. To enable output circuit supervision, the link supplied must be fitted across terminals 6 and, and the load must be polarised. 3 In supervised mode, the module monitors the power supply voltage across terminals and to ensure it does not drop below V, and also monitors for a switched negative fault signal from the power supply to terminal (optional). If a fault is seen the yellow LED will blink, and a fault may be indicated at the panel. The use of this fault warning is dependant upon panel software, please consult Notifier Technical support. 4 Up to.5a load can be driven subject to the supply capability, total cable resistance and minimum voltage required by the load. 5 An alternative end of line monitoring option is available for VdS 4 requirements see table. Maximum cable series resistance is R so max. load current is limited by permissible voltage drop along the cable, min. PSU voltage and min. load voltage requirement. eg: Min PSU voltage = V, min load voltage = V, max. series resistance = R, therefore max. current = 3mA [( )/ Amps.] M UnSupervised Connection Detail Notes: (See note ) { Relay Contact Rating: 3VDC, A resistive load N.C C N.O M 3 6 A B If short circuit isolation is not required, loop output should be wired to terminal 5 and not. Terminal 5 is internally connected to terminal 4. A x B x C N/O Input N/C Input Ground Ground N/C Output N/O Output M4 / M4DIN Connection Detail Loop, Out Loop, Out See Note Loop, In Loop, In Loop, Out See Note T6 Not Connected Notes:. If short circuit isolation is not required, then the loop output should be wired to terminal 5 rather than terminal. Terminal 5 is internally connected directly to terminal 4.. In order to meet the requirements of European Safety Standards, ensure that all cables carrying voltages in excess of 4V (Live and Neutral) are suitably fused. Page of 53_4
12 Product Range at a Glance Part Number Single isolation module. MX Single output module M Single input unit M Dual input unit M Dual input, single output module M Single 3Vac output unit inc. surface mount box M4 Single 3Vac output unit inc. DIN rail mounting enclosure M4DIN Surface Mount Box MESMB Surface Mount Box for 6 Mxx series modules SMB6V Panel Mount Bracket MEPMB DIN rail mounting clip MEDIN Way Relay Output Module CMXRM Way Input Module MMXM 5 Way Input & 5 Way Relay Output Module MCX55 Page of 53_4 Charles Avenue Burgess Hill W. Sussex RH5 UF T: 44 () F: 44 () 6 46 E: sales@notifierfiresystems.co.uk
Interface Modules for SENTRI
EQUIPMENT INTERFACED Data and Installation Interface s for SENTRI Low voltage (LV) / SEN-INT-INPUT 1- Interface (low voltage) SEN-INT-OUTPUT 1- & 1- Interface (low voltage) SEN-INT-4IO # 4- / Interface
More informationAir Sampling Smoke Detection
Air Sampling Smoke Detection Notifier by Honeywell: Data Sheet Air Sampling Smoke Detection Data Sheet The Notifier by Honeywell range of air sampling smoke detection systems (ASSD) comprises smoke detectors
More informationE N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI
E N G L I S H FIRE ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL0EI, MI-FL0EI AND MI-FL0EI mm mm 0 mm DESCRIPTION The LT MI-FL0 Series is part of the Fire Alarm
More informationThe ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features
990-052, Issue 6 20 March 2006 ID50 Series Single Loop Intelligent Fire Alarm Panels Section: Intelligent Fire Alarm Panels GENERAL The NOTIFIER ID50 series single loop intelligent fire alarm panels, has
More informationINPUT / OUTPUT MINI MODULES
INPUT / OUTPUT MINI MODULES APPLICATION The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors
More informationFDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules
Application The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors and manual call points,
More informationDUAL MONITORED INPUT/OUTPUT UNIT BN-305-2
DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection
More informationD7053. Installation Instructions Multiplex Input/Output Module
D EN Installation Instructions Multiplex Input/Output Module D Installation Instructions Notices Notices These instructions cover the installation of the D Multiplex Input/Output Module in a fire system
More informationExcel-EN Conventional Fire Control Panel
Available as 2, 4, 6, 8,10 or 12 zones Approved to EN54-2 & 4 Modular expansion zone cards Programmable relays and outputs Optional additional sounder circuits Optional additional programmable outputs
More informationNotifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology
Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology Notifier by Honeywell: FAAST FAAST Delivers When very early warning fire detection is essential FAAST is a ground breaking aspirating
More informationSOUNDER CONTROL MODULE SCM-AS4
1 of 9 INTRODUCTION DESCRIPTION The forms part of the Nittan (UK)'s SENSORTEC-ANALOGUE range of Analogue Addressable Devices. This module is designed to control a group of bells or sounders from the detection
More informationApplication Guide 001
Application Guide 001 Morley-IAS by Honeywell ZXSe Fire Panel BS7273-4 Category A Contents: Application note information: 2 Basic BS7273-4 Category A compliant C&E example 2 Zoned BS7273-4 Category A compliant
More informationAU MX Digital Loop Card Installation Instructions
4100-6077AU MX Digital Loop Card Installation Instructions Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS - Follow the instructions in this installation manual. These instructions must be followed
More informationZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL
ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options
More informationEXTINGUISHING AGENT RELEASE MODULE
EXTINGUISHING AGENT RELEASE MODULE Operation, Installation & Programming Manual Revision 3.00 Distributors For: 18-20 Brookhollow Ave telephone 02 8850 2888 www.firesense.com.au Baulkham Hills NSW 2153
More informationInterface and EOL Modules 8
Interface and EOL Modules Interface Modules Series 420 25 Interface Modules Series 100 291 EOL Modules 293 254 Interface and EOL Modules Interface Modules Series 420 Interface Modules Serie 420 Interface
More informationintelligent fire alarm ID60series panels
intelligent fire alarm ID60series panels features LPCB approved to EN54 Parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports advanced detection such as
More informationZIOU/230 - MAINS IO INSTRUCTION MANUAL
Description ZIOU/230 - MAINS IO INSTRUCTION MANUAL The Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third party equipment with the Fire Alarm Control panel
More informationGE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring
GE Security FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring Version v2-2 / September 2005 Aritech and Kilsen are GE Security brands. http://www.geindustrial.com/ge-interlogix/emea
More informationInstallation, Operating and Maintenance Manual
STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS
More informationOpal TM AV Devices. Data Sheet. Benefits
Opal TM AV Devices Data Sheet Notifier s Opal AV (Audio Visual) range is designed to alert building occupants of an emergency. The Opal AV range of analogue addressable, loop powered, audible and visual
More informationID50series. intelligent fire alarm panels
ID50series intelligent fire alarm panels features LPCB approved to EN54 parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports NOTIFIER advanced range of
More informationMatrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1
Matrix2000 User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 s Version: 2.0 Revision: 1 IMPORTANT INFORMATION Limitation of liability It is mandatory, Matrix2000 panel to be installed in accordance
More informationDS7465i. Installation Instructions. Input/Output Module
DS7465i EN Installation Instructions Input/Output Module DS7465i Installation Instructions.0 Introduction EN 2.0 Introduction The DS7465i Input/Output Module operates with compatible multiplex systems.
More informationFEC403EN Installation Manual
FEC403EN Installation Manual P/N 10-4101-501-2FC1-01 ISS 22JAN15 Copyright Trademarks and patents Manufacturer 2015 UTC Fire & Security. All rights reserved. The FEC403EN name and logo are trademarks of
More informationDUAL MONITORED INPUT/OUTPUT UNIT BN-305
DUAL MONITORED INPUT/OUTPUT UNIT BN-30 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection
More informationTouch Screen 1 loop Addressable Fire Alarm Panel
evolution 1 Touch Screen 1 loop Addressable Fire Alarm Panel The evolution 1 control panel offers complete compatibility with the award winning range of Nittan evolution detection and alarm devices and
More informationECO N DATE DESCRIPTION OF CHANGE CHG
Model Number: M21E-24-DIN Description: The product is a loop powered device which controls an unsupervised dual pole output channel suitable to manage 24VAC loads. The M21E-24-DIN is micro-controller operated,
More informationPower Supply Display Module PSDM. Installation and Operation Manual
Power Supply Display Module PSDM Installation and Operation Manual Read this manual before using this product. Failure to follow the instructions and safety precautions in this manual can result in serious
More informationBooster Power Supply Manual
Supply Manual DEVELOPED BY COPYRIGHT NOTICE General Signal Building Systems Corporation 6411 Parkland Drive Sarasota, FL 34243 (941) 739-4300 Copyright 1999 General Signal Building Systems Corporation
More informationPSN-1000 & PSN 1000(E) Installation Manual
PSN-1000 & PSN 1000(E) Installation Manual Potter Electric Signal Company, LLC St. Louis, MO Customer Service: (866) 240-1870 Technical Support: (866) 956-1211 Fax: (314) 595-6999 www.pottersignal.com
More informationMINERVA MX. 800 Series Ancillary Equipment
An extensive range of ancillary modules has been specifically designed for use with the MX range of Fire Controllers. The 800 range of ancillary modules provide the MX Fire Controller with a wide degree
More informationHoneywell Air Sampling Devices Data Sheet
Honeywell Air Sampling Devices Data Sheet Smoke detection with high sensitivity and false alarm immunity Product Overview Honeywell Air Sampling Devices (ASDs) are smoke detectors that actively take air
More information2000 Series Sensors Installation Guide
2000 Series Sensors Installation Guide Revision 5.1: August 2000 (unreleased) Aritech is a trademark of SLC Technologies B.V. COPYRIGHT SLC Technologies B.V. 2000. All rights reserved. SLC Technologies
More informationPNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel
PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum
More informationOpal TM AV Devices. Data Sheet. Benefits
Opal TM AV Devices Data Sheet Notifier s Opal AV (Audio Visual) range is designed to alert building occupants of an emergency. The Opal AV range of analogue addressable, loop powered, audible and visual
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS The SensorNet I/O Module provides attachment for up to 32 alarms and up to 16 switched devices. An RS-232 or RS-422 communications port is also provided for receiving serial alarms.
More informationGeneral Routing Interface
General Routing Interface Features The General Routing Interface Card is an optional module to provide Fire and Fault Routing Outputs compliant with BSEN54-2: 1998 Clauses 7.9 and 8.9 and BS5839-1: 2002.
More informationID3000 intelligent. fire alarm panel
ID3000 intelligent fire alarm panel features certified to EN54 parts 2 and 4 expandable from 2 to 8 loop capacity up to 198 per loop (99 sensor and 99 modules) 255 fire zones per panel modular design supports
More informationID2000. intelligent fire alarm panel
ID2000 6pp A4 10-01 3/8/06 22:57 Page 1 ID2000 intelligent fire alarm panel features Certified to EN54 Parts 2 and 4 Expandable from 2 to 8 loop capacity Up to 198 devices per loop (99 sensor and 99 modules)
More informationSystem 800 Addressable Fire Detection & Alarm System
SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools
More informationOPERATION AND INSTALLATION MANUAL
EX+Plus 2 ZONE, 1AREA EXTINGUISHANT CONTROL PANEL OPERATION AND INSTALLATION MANUAL INTRODUCTION The Premier EX Plus is a 2 zone, single area panel for controlling the release of extinguishing gases in
More informationFire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology
Fire-Cryer Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX Shaping Alarm Technology Fire-Cryer Plus The Fire-Cryer range of voice sounders was first introduced to the market by Vimpex in 1999.
More informationINSTALLATION AND MAINTENANCE INSTRUCTIONS NFXI-BEAM AND NFXI-BEAM-T REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR
INSTALLATION AND MAINTENANCE INSTRUCTIONS NFXI-BEAM AND NFXI-BEAM-T REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR GENERAL The model NFXI-BEAM is an addressable long range projected beam smoke detector designed
More informationZXSe Range Data Sheet
ZXSe Range Data Sheet Analogue addressable fire alarm control panel Product Overview The ZXSe range of analogue addressable fire alarm control panels have been designed and constructed around proven and
More informationHeat Sensor Cable Alarm Units DT650L / DT950L
Heat Sensor Cable Alarm Units DT650L / DT950L For conventional and 950 series analogue addressable systems Installation and Commissioning Manual Version 2.1 / May 2004 http://www.geindustrial.com/ge-interlogix/emea
More informationAL600ULADA. NAC Power Extender. Installation Guide
AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery
More informationIGD.CO.UK
APPLICATION DATA SHEET S p e c i f i c a t i o n 2 SO22 WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700+ D e t e c t o r Website: C o n t r o l P a n e l - Wall mounting or 19 Rack
More informationInstallation Guide for AL800UL-ADA. NAC Power Extender. Rev
Installation Guide for AL800UL-ADA NAC Power Extender Rev. 090500 Overview: The Altronix AL800UL-ADA is an extremely cost effective 8 amps voltage regulated remote power supply /battery charger. The AL800UL-ADA
More informationSolution F2. Fire Alarm Control Panels one step ahead.
Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution
More informationAddressable Loop Modules
Addressable Loop s Introduction FC10MIM The FC10MIM Mini Input module is designed to monitor fire contacts, such as extinguishing system control, ventilation control, fire door control etc. The module
More informationFireNET Plus Wiring Instructions
FireNET Plus Wiring Instructions This manual provides wiring instructions for the 1 loop and 2 loop version of the FireNET Plus panels, which supports our finest Hochiki s DCP protocol. Note: Refer to
More informationModel 17A00 Expansion Enclosure
HOME AUTOMATION, INC. Model 17A00 Expansion Enclosure Installation Manual Document Number 17I00-1 Rev A March, 2002 Home Automation, Inc. Model 17A00 Expansion Enclosure Installation Manual Document Number
More informationTrueAlarm Analog Sensing
TrueAlarm Analog Sensing UL, ULC Listed* Addressable Duct Sensor Housings with TrueAlarm Photoelectric Sensor; Available with Multiple Relay Features Compact air duct sensor housing with clear cover to
More informationConventional Fire Alarm System 2014 V1.2
Conventional Fire Alarm System 2014 V1.2 Product Overview Control Panel 2 Conventional Fire Panel GST102A 2 zone Fire panel GST104A 4 zone Fire panel GST108A 8 zone Fire panel GST116A 16 zone Fire Panel
More informationMultiplex Eight Input Remote Modules
Multiplex Eight Input Remote Modules 1.0 Introduction These instructions cover the installation of the D7042/D7042B Eight Input Remote Modules in a fire system supervised by an FPD-7024 Fire Alarm Control
More informationDCP-FRCME - FAST RESPONSE CONTACT MODULE
DCPFRCME FAT REPONE CONTACT MODULE TANDARD FEATURE ingle input contact monitor Fast, reliable contact monitoring utilizing the Hochiki DCP (Digital Communications Protocol) Two different mounting configurations
More informationAn introduction to... Sigma
An introduction to... Sigma XT+ Sigma XT+ Overview The Sigma XT+ 21000 series are the latest additions to the Sigma family of control equipment from Kentec Electronics Limited. The Sigma XT+ range combines
More informationD7052. Installation Instructions Multiplex Dual Input Module
D EN Installation Instructions Multiplex Dual Input Module D Installation Instructions Notices Notices Figure : D Features These instructions cover the installation of the D Multiplex Dual Input Module
More informationDoor Release Power Supply
www.protectingpeople.co.uk Door Release Power Supply Engineer / Installation Manual Document: VI55.1 Protecting People Printed : 04/03/2004-1 - Ventcroft Ltd Door Release Power Supply Engineer / Installation
More informationTECHNICAL DATA OBSOLETE
Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)
More informationSYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System
SYSTEM MANUAL FT1-SB Single Zone Fire Alarm System DOCUMENT HISTORY Issue Date Description Written By Checked By Draft 0 2/9/2008 Original Document. A. Shenouda C. Orr Issue 1 4/11/2011 Update drawing
More informationUsing Non-Twisted Flat Cable in Analogue Addressable Retrofits
Using NonTwisted Flat Cable in Analogue Addressable Retrofits Pertronic Industries www.pertronic.com NonTwisted Cable in AA Systems v2.1 20180831 When upgrading a fire detection system from conventional
More informationD250A/D253/D261AW/D280A/D290 Series
D0A/D/D6AW/D80A/D90 Series EN Installation Instructions / Smoke/Heat Detector Bases EN. D0A/D/D6AW/D80A/D90 Series Installation Instructions.0 Trademarks M Weatherban is a trademark of M. All rights reserved.
More informationMultiple Input and Output Modules
Kingfisher Company, inc. Multiple Input and Output Modules Features: Removable 12 to 18 AWG plug-in terminal blocks Individual LED indicators Unused addresses may be disabled Rotary address switches Class
More informationTechnical Speci fications 220V AC 50Hz or 110V AC 60Hz Accessories operational voltage. 2x 12V / 7Ah sealed lead acid gel batteries
EN54 General Speci fications Advanced analog fire alarm control panel for small or medium installations. Number of zones: 4, 8, 12, 16, 20 or 24. Maximum number of detectors per zone 20. Two wire zone
More informationXP95 Sounder VAD Base
PP2478/2016/Issue 5 XP95 Sounder VAD Base FUNC TION The XP95 Sounder Visual Alarm Device (VAD) Bases incorporates a standard mouting base with a loop-powered sounder VAD. It is used to signal a fire alarm
More informationAddressable Carbon Monoxide Detection, Monitoring & Ventilation System
25 Years of Manufacturing Excellence Addressable Carbon Monoxide Detection, Monitoring & Ventilation System Introduction Description of Carbon Monoxide CO Carbon Monoxide is a colourless, odourless, flammable
More informationAP200 SERIES INTELLIGENT ALARM DEVICES
Tech Data Sheet D0170GB Fire Detection /01 AP00 SERIES INTELLIGENT ALARM DEVICES Intelligent AP00 series alarm devices for FX fire detection system The intelligent AP00 series alarm devices are used in
More informationRemote NAC Power Supply D7038
Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus
More informationTECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.
September 29, 1997 Firecycle III 433 a 1. PRODUCT NAME VIKING Model E-1 Manufactured 1997 Present 2. MANUFACTURED FOR THE VIKING CORPORATION 210 N Industrial Park Road Hastings, Michigan 49058, U.S.A.
More informationApplication, Installation, Operation & Maintenance Manual
APPROVED BY:JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL Application, Installation, Operation & Maintenance Manual PAGE 1 of 43 CONTENTS 1. INTRODUCTION... 3 2. GENERAL DESCRIPTION...
More informationElectric Release Panel Wiring Tips
R IPS CARBO STEEL PIPE FIRE PROTECTIO PRODUCTS Electric Release Panel Wiring Tips 30.4 VICTAULIC IS A ISO 900 CERTIFIED COMPAY Model PDRP-00 Releasing Panels are compact single enclosure units containing
More informationControl Panels. Control Panels for Commercial Applications. Control panels provide the central processing
Control Panels Control Panels for Commercial Applications Control panels provide the central processing and logic for an integrated system. In a typical system, there are four major functions: inputs,
More informationIntelligent addressable fire alarm control panel
Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity
More informationF220-B6PS/M. Installation Guide. Addressable Detector Bases
F220-B6PS/M EN Installation Guide Addressable Detector Bases F220-B6PS/M Installation Guide 1.0 Overview 1.0 Overview These instructions cover the installation of the B6PS/M Addressable Detector Bases
More informationConsultant Specification AGILE Wireless Fire Detection System
Contents Scope of Work... 2 The EN54 Part 2 & 4 Fire System... 2 Standards... 2 Wireless Intelligent Photoelectric Smoke Detector Specification... 4 Wireless Intelligent Thermal Heat Detector Specification...
More informationNZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL
NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL Document No...G108WO1.DOC Serial No... Issue Date...17 th SEPTEMBER 1999 Software Version...1.4 APPROVED TO: NZS 4512:1997 AS/NZS 3548:1992 Fire Alarm
More informationFor Complete Fire and Gas Solutions
Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable
More informationFL2011EI-HS FL2012EI-HS FL2022EI-HS
Fire Aspiration Sensing Technology ENGLISH FL0EI-HS FL0EI-HS FL0EI-HS ADDRESSABLE FAAST LT-00 MODELS QUICK INSTALLATION GUIDE I - - 00 CONTENTS Introduction Parts List Specifications Physical Installation
More informationFire Alarm Panels. Product Manual.
Fire Alarm Panels Product Manual The operation and functions described in this manual are available from Software Version 5000-050-04 onwards. Specifications: Item Specification Details Part Number: Mx-5100
More informationOptical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator
TECHNICAL GUIDE Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator The XPlorer Range XPlorer is a new range of analogue addressable detectors and interfaces developed for all who
More informationTECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel
CVENTIAL ALARM S Features: Description: The LF-CP Series Fire Alarm Control Panel is manufactured based on advanced technology while maintaining high quality during assembly. It is of solid state circuitry
More informationAL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev
AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 031703 Overview: The Altronix AL802ULADA is an extremely cost effective 8 amp voltage regulated
More informationFEC400 Series. Installation Manual
FEC400 Series Conventional microprocessor controlled fire detection and alarm panels with extinguishing control Installation Manual Version 2.3 / August 2004 Aritech is a GE Interlogix brand. http://www.geindustrial.com/ge-interlogix/emea
More information30.45 Electric Release PDRP-2001
The PDRP-2001 Fire Alarm Control Panel (FACP) is a six-zone control panel for single and dual hazard deluge and preaction applications. The FACP is compatible with conventional input devices (2-wire or
More informationNotifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology
Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology Notifier by Honeywell: FAAST FAAST Delivers When very early warning fire detection is essential FAAST is a ground breaking aspirating
More informationNFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual
/ VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel Installation and Operating Manual HLSI-MN-025-I v.05 April 2015 Note: This manual is valid for the following control panel models: NFS-Supra
More informationHoneywell Air Sampling Devices Data Sheet
Honeywell Air Sampling Devices Data Sheet Smoke detection with high sensitivity and false alarm immunity Product Overview Honeywell Air Sampling Devices (ASDs) are smoke detectors that actively take air
More informationAddressable NAC Output Module D327A
Installation Instructions Notice Addressable NAC Output Module D327A These instructions cover the installation of the D327A Addressable NAC Output Module in an analog system controlled by a Bosch D8024,
More informationOPERATION / INSTALLATION
OPERATION / INSTALLATION & PROGRAMMING MANUAL AFP-2800 LCD-80 Fire Alarm Panel Revision 1.01 November 16, 2004 NSW (Head Office) 7 Columbia Court Norwest Business Park Baulkham Hills NSW 2153 Ph: (02)
More informationSIGA-CC1 Single Input Signal Module Installation Sheet
SIGA-CC1 Single Input Signal Module Installation Sheet Personality codes Use the personality codes described below to configure the SIGA-CC1 module. See Table 1 for listing information Table 1: Personality
More informationINDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...
GUIDE MANUAL INDEX 1- Introduction...5...5...6 4- The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops...7 4.2- The Control Panel 4 and 8 Loops...9 5- Installation Guide...10 5.1- Pre-Installation
More informationXP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card
XP6-C Six Circuit Supervised Control Module and SYNC-1 Accessory Card General NOTIFIER s XP6-C six-circuit supervised control module provides intelligent alarm systems with supervised monitoring of wiring
More informationConventional Fire Detection
SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct
More informationAL800ULADA. NAC Power Extender. Installation Guide
AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery
More informationAP200 SERIES INTELLIGENT ALARM DEVICES
Tech Data Sheet D017GB1 Fire Detection /01 AP00 SERIES INTELLIGENT ALARM DEVICES Intelligent AP00 series alarm devices for FX NET fire detection system The intelligent AP00 series alarm devices are used
More informationSINGLE MONITORED INPUT UNIT BN-303
SINGLE MONITORED INPUT UNIT BN-303 Interactive fire detection system Product Datasheet Features Interactive For interfacing switches and 3rd party detectors with relay outputs to Autronica s interactive
More informationE N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.
E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0E FL0E FL0E mm mm 0 mm DESCRIPTION The LT FL0 Series is part of the Fire Alarm Aspiration
More informationD8125MUX. Operation and Installation Guide. Multiplex Bus Interface
D8125MUX EN Operation and Guide Multiplex Bus Interface EN 2 D8125MUX Operation and Guide Contents Contents Contents...2 1.0 Introduction...3 1.1 Description...3 1.2 Programming...3 1.3 Listings...3 2.0
More information