Input/Output Modules Data Sheet

Size: px
Start display at page:

Download "Input/Output Modules Data Sheet"

Transcription

1 Input/Output Modules Data Sheet The wide range of input and output modules available from NOTIFIER delivers exceptional flexibility to a NOTIFIER fire detection and alarm system. Using these modules enables integration with a host of other building management and emergency systems, including access control systems, lifts, fire shutters and emergency lighting. Features Analogue addressable communications Builtin type identification automatically identifies these devices to the control panel (not MX) Stable communication technique with high noise immunity Rotary DECADE to address switches (not MX) Common mounting options including Surface Mount, Panel Mount and DIN Rail Mount. Tricolour LED s Powered directly by wire loop. No additional power required Plugin terminal connections for ease of field wiring Approved to CEA GEI AND CEA GEI 4 CPD approval to EN54 and EN54, LPCB and VdS Installation The M series modules can be mounted either surface, panel mounted in other equipment housings or DIN rail mounted in other equipment housings. Surface mounting is achieved by using the MESMB surface mount box which accepts a single module. This box has a frosted plastic lid with viewing windows for the product identification label, LED s and address switches. This document is not intended to be used for installation purposes. Every care has been taken in the preparation of this document but no liability can be accepted for the use of the information therein. Design features may be changed or amended without prior notice. For more information, contact: NOTIFIER. Charles Avenue, Burgess Hill, West Sussex, RH5 UF. United Kingdom Phone: 44 () Fax: 44 () Page of 53_4 ISO Design, Manufacture and Supply to Quality Management Systems Certified to ISO:4

2 M Single input module The M series modules are designed for use with any NOTIFIER protocol fire alarm control panel and include selectable loop isolation in every device. The M module monitors a single input device circuit of normally open dry contact alarm activation devices. These modules use one of available module addresses on a loop and respond to regular polls from the control panel reporting its type and the status (open/normal/short) of its supervised device circuit. M Single input module Weight: mm mm 3 mm g Current Consumption Without communication Communication every 5 sec. with LED blink enabled. 3 4 VDC; 5 4 VDC Maximum Alarm Current: 5 4 VDC (per LED with LED enabled) Operating Voltage: 5 to 3 VDC peak C to 6 C % to 5%, noncondensing mm MEDIN MESMB 3mm mm MEPMB 3mm 4mm 34mm Page of 53_4

3 Non Addressable Zone Monitor Module MCZR The MCZR nonaddressable zone monitor module allows a zone of nonaddressable detectors to communicate with a Notifier analogue addressable system. As a result existing nonaddressable loops can be integrated into a Notifier addressable system The module monitors a zone of twowire nonaddressable smoke detectors. Each MCZR uses one of available module addresses on a loop. The nonaddressable zone can be powered from the analogue communication line or from an external power supply. Where the nonaddressable zone is powered from an external power supply, the communication line is fully isolated from the nonaddressable zone and from the power supply. This MCZR nonaddressable Zone Monitor module fits into MESMB, MEDIN or MEPMB. These may then be installed in a Rack Assembly using Notifier Rack mounting adapters. Non Addressable Zone Monitor Module MCZR Weight: 3 mm 3 mm 3 mm g Operating Voltage Range: to.5vdc Max. Standby Current: μa maximum (conventional zone connected to external supply) LED Current 4Vdc Green: 4Vdc 4Vdc End of Line Resistor Value: 3.k Temperature Range: Humidity: C to 6 C 5% to 5% relative humidity (noncondensing) 3mm MEDIN MESMB 3mm 3mm MEPMB 3mm 4mm 34mm Page 3 of 53_4

4 M Single output module The M series modules are designed for use with any NOTIFIER protocol fire alarm control panel and include selectable loop isolation in every device. The M control module provides a monitored single output circuit for use with polarised loads (sounder circuit) which requires a suitable power source (Vdc 3Vdc) for the connected load. Alternatively the same device may be placed in to an unsupervised mode which can then be used to control any switched load up to 3Vdc. In addition the M4 and the M4DIN provide two ( x N.O. x N.C.) 5Vac (nominal 3Vac), 5Amp contact outputs. The M4 is provided complete with a surface mounting back box and the M 4DIN is supplied in a DIN rail mounting package. These modules use one of available module addresses on a loop and respond to regular polls from the control panel reporting its type and the status (open/normal/short) of its supervised device circuit. M single output module mm mm 3 mm Weight: M g M4 g M4DIN 5g Current Consumption (Without communication) M 3 4 VDC M4 & M4DIN 5 4 VDC Current Consumption (Communication every 5 sec. with LED blink enabled) M 5 4 VDC M4 & M4DIN VDC Maximum Alarm Current: Operating Voltage: 5 4 VDC (per LED with LED enabled) 5 to 3 VDC peak C to 6 C % to 5%, noncondensing M mm M4DIN M4 5mm 3mm 3mm mm 4mm 6mm 4mm 34mm Page 4 of 53_4

5 M Dual Input Module The M series modules are designed for use with any NOTIFIER protocol fire alarm control panel and include selectable loop isolation in every device. The M dual monitor module provides two supervised input device circuits of normally open dry contact alarm activation devices. The M module uses two addresses of available module addresses on a loop and responds to regular polls from the control panel reporting its type and the status (open/normal/short) of their supervised device circuits. M Dual Input Module Weight: mm mm 3 mm g Current Consumption Without communication Communication every 5 sec. with LED blink enabled VDC; 6 4 VDC Maximum Alarm Current: 5 4 VDC (per LED with LED enabled) Operating Voltage: 5 to 3 VDC peak C to 6 C % to 5%, noncondensing mm MEDIN MESMB 3mm mm MEPMB 3mm 4mm 34mm Page 5 of 53_4

6 M Dual Input Module with Output The M series modules are designed for use with any NOTIFIER protocol fire alarm control panel and include selectable loop isolation in every device. The M dual input, single relay output module, as well as providing two supervised inputs also provides a single change over relay output rated at The M uses three addresses of available module addresses on a loop and responds to regular polls from the control panel reporting its type and the status (open/normal/short) of their supervised device circuits. M Dual Input Module with Output Weight: mm mm 3 mm g Current Consumption Without communication Communication every 5 sec. with LED blink enabled. Maximum Alarm Current: Operating Voltage: 34 4 VDC; 66 4 VDC 5 4 VDC (per LED with LED enabled) 5 to 3 VDC peak C to 6 C % to 5%, noncondensing mm MEDIN MESMB 3mm mm MEPMB 3mm 4mm 34mm Page 6 of 53_4

7 Way Output Module CMXRM Each output is individually addressed and controlled by the control equipment. This provides a cost effective, compact solution for installations requiring multiple switching and / or monitoring at a single location. Each output consists of a form C (change over) relay contact providing both normally open and normally closed contacts rated A at 3Vdc. Each module card utilises up to consecutive addresses with the base address being set by DIP switch although any of the addresses may be individually disabled allowing the use of this address by other modules on that loop. Way Output Module CMXRM 33 mm mm 3 mm Current Consumption.mA with communication and LED blink enabled LED Current, 4Vdc (LED on) per module The modules are supplied as a P.C.B. allowing installation in to other equipment housings such as control cabinets. 5 x 3.5mm mounting holes provide suitable secure mounting for the P.C.B s. Each module occupies a single Notifier Loop Module address with the first address being set by DIP switch SW and subsequent address being base address n up to a maximium of. Individual modules may be disabled via a second DIP switch SW such that any module address in the range can be used for other module addresses on the loop. Connection Detail C to 55 C % to 3%, noncondensing Mounting Detail Page of 53_4

8 Way Input Module MMXM Each input is individually addressed and controlled by the control equipment. This provides a cost effective, compact solution for installations requiring multiple switching and / or monitoring at a single location. Inputs may be configured to monitor for open circuit, short circuit and active (fire) conditions. Each module card utilises up to consecutive addresses with the base address being set by DIP switch although any of the addresses may be individually disabled allowing the use of this address by other modules on that loop. Way Input Module MMXM 33 mm mm 3 mm Current Consumption.mA with communication and LED blink enabled LED Current, 4Vdc (LED on) per module The modules are supplied as a P.C.B. allowing installation in to other equipment housings such as control cabinets. 5 x 3.5mm mounting holes provide suitable secure mounting for the P.C.B s. Each module occupies a single Notifier Loop Module address with the first address being set by DIP switch SW and subsequent address being base address n up to a maximium of. Individual modules may be disabled via a second DIP switch SW such that any module address in the range can be used for other module addresses on the loop. Connection Detail C to 55 C % to 3%, noncondensing Mounting Detail Page of 53_4

9 5 Way Input and 5 Way Output Module MCX55 Each input and output are individually addressed and controlled by the control equipment and provide a cost effective, compact solution for installations requiring multiple switching and / or monitoring at a single location. Inputs may be configured to monitor for open circuit, short circuit and active (fire) conditions. Each output consists of a form C (change over) relay contact providing both normally open and normally closed contacts rated A at 3Vdc. Each module card utilises up to consecutive addresses with the base address being set by DIP switch although any of the addresses may be individually disabled allowing the use of this address by other modules on that loop. M Dual Input Module with Output 33 mm mm 3 mm Current Consumption.mA with communication and LED blink enabled LED Current, 4Vdc (LED on) per module The modules are supplied as a P.C.B. allowing installation in to other equipment housings such as control cabinets. 5 x 3.5mm mounting holes provide suitable secure mounting for the P.C.B s as indicated overleaf. Each module occupies a single Notifier Loop Module address with the first address being set by DIP switch SW and subsequent address being base address n up to a maximium of. Individual modules may be disabled via a second DIP switch SW such that any module address in the range can be used for other module addresses on the loop. Connection Detail C to 55 C % to 3%, noncondensing Mounting Detail Page of 53_4

10 Connection Detail M / M Connection Detail Notes: (See notes ) M / M A B If short circuit isolation is not required, loop output should be wired to terminal 5 and not. Terminal 5 is internally connected to terminal 4. The dashed line circuit connected to terminals and should only be used with the M. There are no connections to these terminals on the M. 3 Provided the control panel is compatible, short circuit monitoring of the input circuit may be possible. An K Ohm resistor should be wired in series with each device switch being monitored A x B x C 4KΩ 4KΩ See Note M Connection Detail (See notes ) M A B Notes: If short circuit isolation is not required, loop output should be wired to terminal 5 and not. Terminal 5 is internally connected to terminal 4. Provided the control panel is compatible, short circuit fault monitoring of the input circuit may be possible. An K Ohm resistor should be wired in series with each device switch being monitored A x B x C 4KΩ 4KΩ NC C NO Relay Contact Rating: 3VDC, A resistive load MX Connection Detail MX Page of 53_4

11 Connection Detail EOL (See notes ) External Power Supply Maximum 3VDC, Minimum VDC See Note 3 M Supervised Connection Detail M 6 See Note 5 and Table 3 A x B x C 6 A B Table : EOL Monitoring Options Mode Switch A Switch B EOL Device Load Position Position Std 4KΩ Resistor See Note 4 VdS Polarised 4Ω See Note 5 RLY N/A Unsupervised Notes: If short circuit isolation is not required, loop output should be wired to terminal 5 and not. Terminal 5 is internally connected to terminal 4. To enable output circuit supervision, the link supplied must be fitted across terminals 6 and, and the load must be polarised. 3 In supervised mode, the module monitors the power supply voltage across terminals and to ensure it does not drop below V, and also monitors for a switched negative fault signal from the power supply to terminal (optional). If a fault is seen the yellow LED will blink, and a fault may be indicated at the panel. The use of this fault warning is dependant upon panel software, please consult Notifier Technical support. 4 Up to.5a load can be driven subject to the supply capability, total cable resistance and minimum voltage required by the load. 5 An alternative end of line monitoring option is available for VdS 4 requirements see table. Maximum cable series resistance is R so max. load current is limited by permissible voltage drop along the cable, min. PSU voltage and min. load voltage requirement. eg: Min PSU voltage = V, min load voltage = V, max. series resistance = R, therefore max. current = 3mA [( )/ Amps.] M UnSupervised Connection Detail Notes: (See note ) { Relay Contact Rating: 3VDC, A resistive load N.C C N.O M 3 6 A B If short circuit isolation is not required, loop output should be wired to terminal 5 and not. Terminal 5 is internally connected to terminal 4. A x B x C N/O Input N/C Input Ground Ground N/C Output N/O Output M4 / M4DIN Connection Detail Loop, Out Loop, Out See Note Loop, In Loop, In Loop, Out See Note T6 Not Connected Notes:. If short circuit isolation is not required, then the loop output should be wired to terminal 5 rather than terminal. Terminal 5 is internally connected directly to terminal 4.. In order to meet the requirements of European Safety Standards, ensure that all cables carrying voltages in excess of 4V (Live and Neutral) are suitably fused. Page of 53_4

12 Product Range at a Glance Part Number Single isolation module. MX Single output module M Single input unit M Dual input unit M Dual input, single output module M Single 3Vac output unit inc. surface mount box M4 Single 3Vac output unit inc. DIN rail mounting enclosure M4DIN Surface Mount Box MESMB Surface Mount Box for 6 Mxx series modules SMB6V Panel Mount Bracket MEPMB DIN rail mounting clip MEDIN Way Relay Output Module CMXRM Way Input Module MMXM 5 Way Input & 5 Way Relay Output Module MCX55 Page of 53_4 Charles Avenue Burgess Hill W. Sussex RH5 UF T: 44 () F: 44 () 6 46 E: sales@notifierfiresystems.co.uk

Interface Modules for SENTRI

Interface Modules for SENTRI EQUIPMENT INTERFACED Data and Installation Interface s for SENTRI Low voltage (LV) / SEN-INT-INPUT 1- Interface (low voltage) SEN-INT-OUTPUT 1- & 1- Interface (low voltage) SEN-INT-4IO # 4- / Interface

More information

Air Sampling Smoke Detection

Air Sampling Smoke Detection Air Sampling Smoke Detection Notifier by Honeywell: Data Sheet Air Sampling Smoke Detection Data Sheet The Notifier by Honeywell range of air sampling smoke detection systems (ASSD) comprises smoke detectors

More information

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI E N G L I S H FIRE ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL0EI, MI-FL0EI AND MI-FL0EI mm mm 0 mm DESCRIPTION The LT MI-FL0 Series is part of the Fire Alarm

More information

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features 990-052, Issue 6 20 March 2006 ID50 Series Single Loop Intelligent Fire Alarm Panels Section: Intelligent Fire Alarm Panels GENERAL The NOTIFIER ID50 series single loop intelligent fire alarm panels, has

More information

INPUT / OUTPUT MINI MODULES

INPUT / OUTPUT MINI MODULES INPUT / OUTPUT MINI MODULES APPLICATION The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors

More information

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules Application The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors and manual call points,

More information

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2 DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection

More information

D7053. Installation Instructions Multiplex Input/Output Module

D7053. Installation Instructions Multiplex Input/Output Module D EN Installation Instructions Multiplex Input/Output Module D Installation Instructions Notices Notices These instructions cover the installation of the D Multiplex Input/Output Module in a fire system

More information

Excel-EN Conventional Fire Control Panel

Excel-EN Conventional Fire Control Panel Available as 2, 4, 6, 8,10 or 12 zones Approved to EN54-2 & 4 Modular expansion zone cards Programmable relays and outputs Optional additional sounder circuits Optional additional programmable outputs

More information

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology Notifier by Honeywell: FAAST FAAST Delivers When very early warning fire detection is essential FAAST is a ground breaking aspirating

More information

SOUNDER CONTROL MODULE SCM-AS4

SOUNDER CONTROL MODULE SCM-AS4 1 of 9 INTRODUCTION DESCRIPTION The forms part of the Nittan (UK)'s SENSORTEC-ANALOGUE range of Analogue Addressable Devices. This module is designed to control a group of bells or sounders from the detection

More information

Application Guide 001

Application Guide 001 Application Guide 001 Morley-IAS by Honeywell ZXSe Fire Panel BS7273-4 Category A Contents: Application note information: 2 Basic BS7273-4 Category A compliant C&E example 2 Zoned BS7273-4 Category A compliant

More information

AU MX Digital Loop Card Installation Instructions

AU MX Digital Loop Card Installation Instructions 4100-6077AU MX Digital Loop Card Installation Instructions Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS - Follow the instructions in this installation manual. These instructions must be followed

More information

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options

More information

EXTINGUISHING AGENT RELEASE MODULE

EXTINGUISHING AGENT RELEASE MODULE EXTINGUISHING AGENT RELEASE MODULE Operation, Installation & Programming Manual Revision 3.00 Distributors For: 18-20 Brookhollow Ave telephone 02 8850 2888 www.firesense.com.au Baulkham Hills NSW 2153

More information

Interface and EOL Modules 8

Interface and EOL Modules 8 Interface and EOL Modules Interface Modules Series 420 25 Interface Modules Series 100 291 EOL Modules 293 254 Interface and EOL Modules Interface Modules Series 420 Interface Modules Serie 420 Interface

More information

intelligent fire alarm ID60series panels

intelligent fire alarm ID60series panels intelligent fire alarm ID60series panels features LPCB approved to EN54 Parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports advanced detection such as

More information

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

ZIOU/230 - MAINS IO INSTRUCTION MANUAL Description ZIOU/230 - MAINS IO INSTRUCTION MANUAL The Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third party equipment with the Fire Alarm Control panel

More information

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring GE Security FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring Version v2-2 / September 2005 Aritech and Kilsen are GE Security brands. http://www.geindustrial.com/ge-interlogix/emea

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

Opal TM AV Devices. Data Sheet. Benefits

Opal TM AV Devices. Data Sheet. Benefits Opal TM AV Devices Data Sheet Notifier s Opal AV (Audio Visual) range is designed to alert building occupants of an emergency. The Opal AV range of analogue addressable, loop powered, audible and visual

More information

ID50series. intelligent fire alarm panels

ID50series. intelligent fire alarm panels ID50series intelligent fire alarm panels features LPCB approved to EN54 parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports NOTIFIER advanced range of

More information

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1 Matrix2000 User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 s Version: 2.0 Revision: 1 IMPORTANT INFORMATION Limitation of liability It is mandatory, Matrix2000 panel to be installed in accordance

More information

DS7465i. Installation Instructions. Input/Output Module

DS7465i. Installation Instructions. Input/Output Module DS7465i EN Installation Instructions Input/Output Module DS7465i Installation Instructions.0 Introduction EN 2.0 Introduction The DS7465i Input/Output Module operates with compatible multiplex systems.

More information

FEC403EN Installation Manual

FEC403EN Installation Manual FEC403EN Installation Manual P/N 10-4101-501-2FC1-01 ISS 22JAN15 Copyright Trademarks and patents Manufacturer 2015 UTC Fire & Security. All rights reserved. The FEC403EN name and logo are trademarks of

More information

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

DUAL MONITORED INPUT/OUTPUT UNIT BN-305 DUAL MONITORED INPUT/OUTPUT UNIT BN-30 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection

More information

Touch Screen 1 loop Addressable Fire Alarm Panel

Touch Screen 1 loop Addressable Fire Alarm Panel evolution 1 Touch Screen 1 loop Addressable Fire Alarm Panel The evolution 1 control panel offers complete compatibility with the award winning range of Nittan evolution detection and alarm devices and

More information

ECO N DATE DESCRIPTION OF CHANGE CHG

ECO N DATE DESCRIPTION OF CHANGE CHG Model Number: M21E-24-DIN Description: The product is a loop powered device which controls an unsupervised dual pole output channel suitable to manage 24VAC loads. The M21E-24-DIN is micro-controller operated,

More information

Power Supply Display Module PSDM. Installation and Operation Manual

Power Supply Display Module PSDM. Installation and Operation Manual Power Supply Display Module PSDM Installation and Operation Manual Read this manual before using this product. Failure to follow the instructions and safety precautions in this manual can result in serious

More information

Booster Power Supply Manual

Booster Power Supply Manual Supply Manual DEVELOPED BY COPYRIGHT NOTICE General Signal Building Systems Corporation 6411 Parkland Drive Sarasota, FL 34243 (941) 739-4300 Copyright 1999 General Signal Building Systems Corporation

More information

PSN-1000 & PSN 1000(E) Installation Manual

PSN-1000 & PSN 1000(E) Installation Manual PSN-1000 & PSN 1000(E) Installation Manual Potter Electric Signal Company, LLC St. Louis, MO Customer Service: (866) 240-1870 Technical Support: (866) 956-1211 Fax: (314) 595-6999 www.pottersignal.com

More information

MINERVA MX. 800 Series Ancillary Equipment

MINERVA MX. 800 Series Ancillary Equipment An extensive range of ancillary modules has been specifically designed for use with the MX range of Fire Controllers. The 800 range of ancillary modules provide the MX Fire Controller with a wide degree

More information

Honeywell Air Sampling Devices Data Sheet

Honeywell Air Sampling Devices Data Sheet Honeywell Air Sampling Devices Data Sheet Smoke detection with high sensitivity and false alarm immunity Product Overview Honeywell Air Sampling Devices (ASDs) are smoke detectors that actively take air

More information

2000 Series Sensors Installation Guide

2000 Series Sensors Installation Guide 2000 Series Sensors Installation Guide Revision 5.1: August 2000 (unreleased) Aritech is a trademark of SLC Technologies B.V. COPYRIGHT SLC Technologies B.V. 2000. All rights reserved. SLC Technologies

More information

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum

More information

Opal TM AV Devices. Data Sheet. Benefits

Opal TM AV Devices. Data Sheet. Benefits Opal TM AV Devices Data Sheet Notifier s Opal AV (Audio Visual) range is designed to alert building occupants of an emergency. The Opal AV range of analogue addressable, loop powered, audible and visual

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS The SensorNet I/O Module provides attachment for up to 32 alarms and up to 16 switched devices. An RS-232 or RS-422 communications port is also provided for receiving serial alarms.

More information

General Routing Interface

General Routing Interface General Routing Interface Features The General Routing Interface Card is an optional module to provide Fire and Fault Routing Outputs compliant with BSEN54-2: 1998 Clauses 7.9 and 8.9 and BS5839-1: 2002.

More information

ID3000 intelligent. fire alarm panel

ID3000 intelligent. fire alarm panel ID3000 intelligent fire alarm panel features certified to EN54 parts 2 and 4 expandable from 2 to 8 loop capacity up to 198 per loop (99 sensor and 99 modules) 255 fire zones per panel modular design supports

More information

ID2000. intelligent fire alarm panel

ID2000. intelligent fire alarm panel ID2000 6pp A4 10-01 3/8/06 22:57 Page 1 ID2000 intelligent fire alarm panel features Certified to EN54 Parts 2 and 4 Expandable from 2 to 8 loop capacity Up to 198 devices per loop (99 sensor and 99 modules)

More information

System 800 Addressable Fire Detection & Alarm System

System 800 Addressable Fire Detection & Alarm System SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools

More information

OPERATION AND INSTALLATION MANUAL

OPERATION AND INSTALLATION MANUAL EX+Plus 2 ZONE, 1AREA EXTINGUISHANT CONTROL PANEL OPERATION AND INSTALLATION MANUAL INTRODUCTION The Premier EX Plus is a 2 zone, single area panel for controlling the release of extinguishing gases in

More information

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology Fire-Cryer Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX Shaping Alarm Technology Fire-Cryer Plus The Fire-Cryer range of voice sounders was first introduced to the market by Vimpex in 1999.

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS NFXI-BEAM AND NFXI-BEAM-T REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

INSTALLATION AND MAINTENANCE INSTRUCTIONS NFXI-BEAM AND NFXI-BEAM-T REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR INSTALLATION AND MAINTENANCE INSTRUCTIONS NFXI-BEAM AND NFXI-BEAM-T REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR GENERAL The model NFXI-BEAM is an addressable long range projected beam smoke detector designed

More information

ZXSe Range Data Sheet

ZXSe Range Data Sheet ZXSe Range Data Sheet Analogue addressable fire alarm control panel Product Overview The ZXSe range of analogue addressable fire alarm control panels have been designed and constructed around proven and

More information

Heat Sensor Cable Alarm Units DT650L / DT950L

Heat Sensor Cable Alarm Units DT650L / DT950L Heat Sensor Cable Alarm Units DT650L / DT950L For conventional and 950 series analogue addressable systems Installation and Commissioning Manual Version 2.1 / May 2004 http://www.geindustrial.com/ge-interlogix/emea

More information

AL600ULADA. NAC Power Extender. Installation Guide

AL600ULADA. NAC Power Extender. Installation Guide AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery

More information

IGD.CO.UK

IGD.CO.UK APPLICATION DATA SHEET S p e c i f i c a t i o n 2 SO22 WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700+ D e t e c t o r Website: C o n t r o l P a n e l - Wall mounting or 19 Rack

More information

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev Installation Guide for AL800UL-ADA NAC Power Extender Rev. 090500 Overview: The Altronix AL800UL-ADA is an extremely cost effective 8 amps voltage regulated remote power supply /battery charger. The AL800UL-ADA

More information

Solution F2. Fire Alarm Control Panels one step ahead.

Solution F2. Fire Alarm Control Panels one step ahead. Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution

More information

Addressable Loop Modules

Addressable Loop Modules Addressable Loop s Introduction FC10MIM The FC10MIM Mini Input module is designed to monitor fire contacts, such as extinguishing system control, ventilation control, fire door control etc. The module

More information

FireNET Plus Wiring Instructions

FireNET Plus Wiring Instructions FireNET Plus Wiring Instructions This manual provides wiring instructions for the 1 loop and 2 loop version of the FireNET Plus panels, which supports our finest Hochiki s DCP protocol. Note: Refer to

More information

Model 17A00 Expansion Enclosure

Model 17A00 Expansion Enclosure HOME AUTOMATION, INC. Model 17A00 Expansion Enclosure Installation Manual Document Number 17I00-1 Rev A March, 2002 Home Automation, Inc. Model 17A00 Expansion Enclosure Installation Manual Document Number

More information

TrueAlarm Analog Sensing

TrueAlarm Analog Sensing TrueAlarm Analog Sensing UL, ULC Listed* Addressable Duct Sensor Housings with TrueAlarm Photoelectric Sensor; Available with Multiple Relay Features Compact air duct sensor housing with clear cover to

More information

Conventional Fire Alarm System 2014 V1.2

Conventional Fire Alarm System 2014 V1.2 Conventional Fire Alarm System 2014 V1.2 Product Overview Control Panel 2 Conventional Fire Panel GST102A 2 zone Fire panel GST104A 4 zone Fire panel GST108A 8 zone Fire panel GST116A 16 zone Fire Panel

More information

Multiplex Eight Input Remote Modules

Multiplex Eight Input Remote Modules Multiplex Eight Input Remote Modules 1.0 Introduction These instructions cover the installation of the D7042/D7042B Eight Input Remote Modules in a fire system supervised by an FPD-7024 Fire Alarm Control

More information

DCP-FRCME - FAST RESPONSE CONTACT MODULE

DCP-FRCME - FAST RESPONSE CONTACT MODULE DCPFRCME FAT REPONE CONTACT MODULE TANDARD FEATURE ingle input contact monitor Fast, reliable contact monitoring utilizing the Hochiki DCP (Digital Communications Protocol) Two different mounting configurations

More information

An introduction to... Sigma

An introduction to... Sigma An introduction to... Sigma XT+ Sigma XT+ Overview The Sigma XT+ 21000 series are the latest additions to the Sigma family of control equipment from Kentec Electronics Limited. The Sigma XT+ range combines

More information

D7052. Installation Instructions Multiplex Dual Input Module

D7052. Installation Instructions Multiplex Dual Input Module D EN Installation Instructions Multiplex Dual Input Module D Installation Instructions Notices Notices Figure : D Features These instructions cover the installation of the D Multiplex Dual Input Module

More information

Door Release Power Supply

Door Release Power Supply www.protectingpeople.co.uk Door Release Power Supply Engineer / Installation Manual Document: VI55.1 Protecting People Printed : 04/03/2004-1 - Ventcroft Ltd Door Release Power Supply Engineer / Installation

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System SYSTEM MANUAL FT1-SB Single Zone Fire Alarm System DOCUMENT HISTORY Issue Date Description Written By Checked By Draft 0 2/9/2008 Original Document. A. Shenouda C. Orr Issue 1 4/11/2011 Update drawing

More information

Using Non-Twisted Flat Cable in Analogue Addressable Retrofits

Using Non-Twisted Flat Cable in Analogue Addressable Retrofits Using NonTwisted Flat Cable in Analogue Addressable Retrofits Pertronic Industries www.pertronic.com NonTwisted Cable in AA Systems v2.1 20180831 When upgrading a fire detection system from conventional

More information

D250A/D253/D261AW/D280A/D290 Series

D250A/D253/D261AW/D280A/D290 Series D0A/D/D6AW/D80A/D90 Series EN Installation Instructions / Smoke/Heat Detector Bases EN. D0A/D/D6AW/D80A/D90 Series Installation Instructions.0 Trademarks M Weatherban is a trademark of M. All rights reserved.

More information

Multiple Input and Output Modules

Multiple Input and Output Modules Kingfisher Company, inc. Multiple Input and Output Modules Features: Removable 12 to 18 AWG plug-in terminal blocks Individual LED indicators Unused addresses may be disabled Rotary address switches Class

More information

Technical Speci fications 220V AC 50Hz or 110V AC 60Hz Accessories operational voltage. 2x 12V / 7Ah sealed lead acid gel batteries

Technical Speci fications 220V AC 50Hz or 110V AC 60Hz Accessories operational voltage. 2x 12V / 7Ah sealed lead acid gel batteries EN54 General Speci fications Advanced analog fire alarm control panel for small or medium installations. Number of zones: 4, 8, 12, 16, 20 or 24. Maximum number of detectors per zone 20. Two wire zone

More information

XP95 Sounder VAD Base

XP95 Sounder VAD Base PP2478/2016/Issue 5 XP95 Sounder VAD Base FUNC TION The XP95 Sounder Visual Alarm Device (VAD) Bases incorporates a standard mouting base with a loop-powered sounder VAD. It is used to signal a fire alarm

More information

Addressable Carbon Monoxide Detection, Monitoring & Ventilation System

Addressable Carbon Monoxide Detection, Monitoring & Ventilation System 25 Years of Manufacturing Excellence Addressable Carbon Monoxide Detection, Monitoring & Ventilation System Introduction Description of Carbon Monoxide CO Carbon Monoxide is a colourless, odourless, flammable

More information

AP200 SERIES INTELLIGENT ALARM DEVICES

AP200 SERIES INTELLIGENT ALARM DEVICES Tech Data Sheet D0170GB Fire Detection /01 AP00 SERIES INTELLIGENT ALARM DEVICES Intelligent AP00 series alarm devices for FX fire detection system The intelligent AP00 series alarm devices are used in

More information

Remote NAC Power Supply D7038

Remote NAC Power Supply D7038 Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus

More information

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum. September 29, 1997 Firecycle III 433 a 1. PRODUCT NAME VIKING Model E-1 Manufactured 1997 Present 2. MANUFACTURED FOR THE VIKING CORPORATION 210 N Industrial Park Road Hastings, Michigan 49058, U.S.A.

More information

Application, Installation, Operation & Maintenance Manual

Application, Installation, Operation & Maintenance Manual APPROVED BY:JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL Application, Installation, Operation & Maintenance Manual PAGE 1 of 43 CONTENTS 1. INTRODUCTION... 3 2. GENERAL DESCRIPTION...

More information

Electric Release Panel Wiring Tips

Electric Release Panel Wiring Tips R IPS CARBO STEEL PIPE FIRE PROTECTIO PRODUCTS Electric Release Panel Wiring Tips 30.4 VICTAULIC IS A ISO 900 CERTIFIED COMPAY Model PDRP-00 Releasing Panels are compact single enclosure units containing

More information

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing Control Panels Control Panels for Commercial Applications Control panels provide the central processing and logic for an integrated system. In a typical system, there are four major functions: inputs,

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

F220-B6PS/M. Installation Guide. Addressable Detector Bases

F220-B6PS/M. Installation Guide. Addressable Detector Bases F220-B6PS/M EN Installation Guide Addressable Detector Bases F220-B6PS/M Installation Guide 1.0 Overview 1.0 Overview These instructions cover the installation of the B6PS/M Addressable Detector Bases

More information

Consultant Specification AGILE Wireless Fire Detection System

Consultant Specification AGILE Wireless Fire Detection System Contents Scope of Work... 2 The EN54 Part 2 & 4 Fire System... 2 Standards... 2 Wireless Intelligent Photoelectric Smoke Detector Specification... 4 Wireless Intelligent Thermal Heat Detector Specification...

More information

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL Document No...G108WO1.DOC Serial No... Issue Date...17 th SEPTEMBER 1999 Software Version...1.4 APPROVED TO: NZS 4512:1997 AS/NZS 3548:1992 Fire Alarm

More information

For Complete Fire and Gas Solutions

For Complete Fire and Gas Solutions Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable

More information

FL2011EI-HS FL2012EI-HS FL2022EI-HS

FL2011EI-HS FL2012EI-HS FL2022EI-HS Fire Aspiration Sensing Technology ENGLISH FL0EI-HS FL0EI-HS FL0EI-HS ADDRESSABLE FAAST LT-00 MODELS QUICK INSTALLATION GUIDE I - - 00 CONTENTS Introduction Parts List Specifications Physical Installation

More information

Fire Alarm Panels. Product Manual.

Fire Alarm Panels. Product Manual. Fire Alarm Panels Product Manual The operation and functions described in this manual are available from Software Version 5000-050-04 onwards. Specifications: Item Specification Details Part Number: Mx-5100

More information

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator TECHNICAL GUIDE Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator The XPlorer Range XPlorer is a new range of analogue addressable detectors and interfaces developed for all who

More information

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel CVENTIAL ALARM S Features: Description: The LF-CP Series Fire Alarm Control Panel is manufactured based on advanced technology while maintaining high quality during assembly. It is of solid state circuitry

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 031703 Overview: The Altronix AL802ULADA is an extremely cost effective 8 amp voltage regulated

More information

FEC400 Series. Installation Manual

FEC400 Series. Installation Manual FEC400 Series Conventional microprocessor controlled fire detection and alarm panels with extinguishing control Installation Manual Version 2.3 / August 2004 Aritech is a GE Interlogix brand. http://www.geindustrial.com/ge-interlogix/emea

More information

30.45 Electric Release PDRP-2001

30.45 Electric Release PDRP-2001 The PDRP-2001 Fire Alarm Control Panel (FACP) is a six-zone control panel for single and dual hazard deluge and preaction applications. The FACP is compatible with conventional input devices (2-wire or

More information

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology Notifier by Honeywell: FAAST FAAST Delivers When very early warning fire detection is essential FAAST is a ground breaking aspirating

More information

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel Installation and Operating Manual HLSI-MN-025-I v.05 April 2015 Note: This manual is valid for the following control panel models: NFS-Supra

More information

Honeywell Air Sampling Devices Data Sheet

Honeywell Air Sampling Devices Data Sheet Honeywell Air Sampling Devices Data Sheet Smoke detection with high sensitivity and false alarm immunity Product Overview Honeywell Air Sampling Devices (ASDs) are smoke detectors that actively take air

More information

Addressable NAC Output Module D327A

Addressable NAC Output Module D327A Installation Instructions Notice Addressable NAC Output Module D327A These instructions cover the installation of the D327A Addressable NAC Output Module in an analog system controlled by a Bosch D8024,

More information

OPERATION / INSTALLATION

OPERATION / INSTALLATION OPERATION / INSTALLATION & PROGRAMMING MANUAL AFP-2800 LCD-80 Fire Alarm Panel Revision 1.01 November 16, 2004 NSW (Head Office) 7 Columbia Court Norwest Business Park Baulkham Hills NSW 2153 Ph: (02)

More information

SIGA-CC1 Single Input Signal Module Installation Sheet

SIGA-CC1 Single Input Signal Module Installation Sheet SIGA-CC1 Single Input Signal Module Installation Sheet Personality codes Use the personality codes described below to configure the SIGA-CC1 module. See Table 1 for listing information Table 1: Personality

More information

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops... GUIDE MANUAL INDEX 1- Introduction...5...5...6 4- The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops...7 4.2- The Control Panel 4 and 8 Loops...9 5- Installation Guide...10 5.1- Pre-Installation

More information

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card XP6-C Six Circuit Supervised Control Module and SYNC-1 Accessory Card General NOTIFIER s XP6-C six-circuit supervised control module provides intelligent alarm systems with supervised monitoring of wiring

More information

Conventional Fire Detection

Conventional Fire Detection SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct

More information

AL800ULADA. NAC Power Extender. Installation Guide

AL800ULADA. NAC Power Extender. Installation Guide AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery

More information

AP200 SERIES INTELLIGENT ALARM DEVICES

AP200 SERIES INTELLIGENT ALARM DEVICES Tech Data Sheet D017GB1 Fire Detection /01 AP00 SERIES INTELLIGENT ALARM DEVICES Intelligent AP00 series alarm devices for FX NET fire detection system The intelligent AP00 series alarm devices are used

More information

SINGLE MONITORED INPUT UNIT BN-303

SINGLE MONITORED INPUT UNIT BN-303 SINGLE MONITORED INPUT UNIT BN-303 Interactive fire detection system Product Datasheet Features Interactive For interfacing switches and 3rd party detectors with relay outputs to Autronica s interactive

More information

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm. E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0E FL0E FL0E mm mm 0 mm DESCRIPTION The LT FL0 Series is part of the Fire Alarm Aspiration

More information

D8125MUX. Operation and Installation Guide. Multiplex Bus Interface

D8125MUX. Operation and Installation Guide. Multiplex Bus Interface D8125MUX EN Operation and Guide Multiplex Bus Interface EN 2 D8125MUX Operation and Guide Contents Contents Contents...2 1.0 Introduction...3 1.1 Description...3 1.2 Programming...3 1.3 Listings...3 2.0

More information