Isotemp Large Capacity Refrigerated Incubator

Size: px
Start display at page:

Download "Isotemp Large Capacity Refrigerated Incubator"

Transcription

1 Isotemp Large Capacity Refrigerated Incubator Instruction Manual Models 304 and 304R Cat. No and R /16/06

2 Table of Contents Safety Information...3 Alert Signals...3 Warning...3 Caution...3 Important...3 Introduction...4 Specifications...6 Power Requirements...6 Dimensions...6 Operating Environment...6 Performance Characteristics...6 Unpacking and Installation...7 Packing List...7 Installation...7 Chart Recorder Activation (Model 304R)...8 Installation of Caster...8 Controls...9 Display and Indicators...9 Operation...10 General Function Checks...10 Controller Operation...10 Changing Chamber Temperature Control Setpoint...11 Accessing Controller Menus...12 Alarm...13 Safety Thermostat...14 Maintenance...15 Cleaning...15 Defrosting...15 Calibration...16 Repair...17 Alarm and Alarm Battery Test...17 Replacing Alarm Batteries...17 Replacing Temperature Controller, Alarm or S Replacing RTD Temperature Sensor...18 Replacing SSR1, K1, K2, T1 or T2 (Model 304R)...19 Replacing FANs or THM Replacing Keyed ON/OFF Switch or Convenience Outlet...20 Replacing Chart Recorder (Model 304R)...20 Accessories and Replacement Parts...21 Troubleshooting...22 Wiring Diagram...23 Warranty

3 Safety Information Alert Signals Warning Warnings alert you to a possibility of personal injury. Caution Cautions alert you to a possibility of damage to the equipment. Note Notes alert you to pertinent facts and conditions. Warning This manual must be carefully read and thoroughly understood before operating the unit, failure to follow directions or precautionary measures could result in serious adverse effects. This equipment must be used only as specified in these instructions. This equipment is intended for indoor use only. This equipment must be earth grounded for safe operation. Maximum ratings of accessories that may be plugged into convenience outlet: Load current 2 115VAC, Leakage Current 250 micro Amps. Hot Surface Hot surfaces alert you to a possibility of personal injury if you come in contact with a surface during use or for a period of time after use. Caution The aluminum evaporator and other portions of these units should not be exposed to the corrosive effects of acidic or caustic materials. Extreme care must be exercised if such materials are stored within to prevent voiding the warranty. This Incubator is NOT suitable for flammable material storage. Important When operating at 100% cooling, the compressor runs continuously and thus cools continuously. If no manual defrosting is conducted for over 2 weeks, ice will build and the unit will not maintain temperature. See Defrosting. 3

4 Introduction The Large Capacity Refrigerated Incubator offers laboratories precise temperature control over the -15 C to 50 C range. Performance meets requirements for the preservation of vaccines, biologicals, incubation of bacterial cultures, and determination of biochemical oxygen demand of sewage. The extended operating temperature range also includes temperatures associated with drug stability projects, dairy product evaluation and entomological studies. Features include: CFC-Free Refrigerant: R404A Storage capacity: 30.4 cubic feet (0.86m3) Accommodates 368 BOD bottles, up to 600 bottles with additional shelves, shelves can handle up to 100 lbs sample weight each.. Temperature range is -15 C to +50 C White enamel coated steel exterior and interior Foamed in polyurethane insulation Door mounted microprocessor based controller Power ON/OFF Receptacle Digital temperature readout to 0.1 C Cooling control modes: High precision with cooling (100% mode) High precision without cooling (00% mode) Frost free with variable cooling (50% mode) Protected setpoint mode to prevent accidental change 4 adjustable (0.5 adjustment slots) wire shelves Two small top shelves: 19 5/16 x 31 7/16 (49 x 79.9 cm), load capacity 100 lbs each Two large bottom shelves: 21 9/16 x 31 7/16 (54.8 x 79.9 cm), load capacity 100 lbs each Front Panel 1 removable trivet on floor: 21 9/16 X 9 1/2 Door activated 40 watt interior incandescent shatterproof light 4

5 INTRODUCTION Door activated fan suppression to preserve atmosphere Solid state relay for the heater Visual and audible battery backed power-out alarm Visual and audible over/under temperature deviation alarm when temp deviates +/- 5 C Contacts for remote alarm with delay activation Runaway temperature guard disables heater and receptacle when temperature reaches 65 C Safety relay and LED to interrupt power when chamber temp is outside limits 1/2 hp compressor, relay for energy conservation Compressor overload relay RTD temperature probe 2A convenience outlet inside chamber with 2A fuse on back panel Shipped with four 1.5, screw in, adjustable feet Optional casters included Keyed on/off switch, mounted in chamber Door lock with key Includes 7 day, 6 circular chart recorder (Model 304R only) CSA/NRTL approved Two years warranty parts, labor and travel 5

6 Specifications Power Requirements 115V +/- 10%, 60Hz, 1725W, 15 Amps, Including 2 Amps for convenience outlet. Equipment requires circuit with 20A Circuit Breaker and receptacle type NEMA 5-20R. Dimensions External Dimensions Height: Width: Depth: Internal Dimensions 74 (188.0cm) 35 (88.9cm) 35 (88.9cm) Height: 65.5 (166.4cm) Width: 32 (81.3cm) Depth: 25 (63.5cm) lower half Depth: 23 (58.4.5cm) upper half Net shipping weight: 360 lbs (163 kg) Operating Environment Temperature Range: 10 C to 40 C Humidity Range: 0% to 90% RH Maximum Altitude: 6600 ft (2 km) Air clearances: Back, top and sides 3.0 min. Over voltage Category: II (IEC664) Pollution Degree: 2 (IEC664) Performance Characteristics: Operating Range: -15 to +50 C Uniformity: ±1.0 C 1 Stability: ±0.5 C 1 Display Readability: 0.1 C Maximum Sound Level 65 dba 1 Per ASTM method E , cooling modes 00 and 100 6

7 Unpacking and Installation Note If damage is observed, keep the shipment intact (including the carton and all packing material) and file a claim with the final carrier. Remove shipping box by cutting bands that attach box to pallet then lift box off. Note The incubator may be lifted using a fork-lift or jack placed under the sides for the unit. Packing List Item Qty Large Capacity Refrigerated Incubator 1 Incubator Instructions 1 Top Shelf 2 Bottom Shelf 2 Shelf Clip 16 Trivet 1 Caster Kit 1 Key, Door 1 Key, Power On/ OFF 2 Charts for Recorder -50 to +50 (Model 304R) 60 Charts for Recorder, 0 to 50 (Model 304R) 60 Instructions for Chart recorder (Model 304R) 1 Installation The Large Capacity Refrigerated Incubator should be installed on a level, stable floor. Use the adjustable feet to level the incubator. Locate the unit so that there is at least 3 inches of clearance around the sides, top and back to ensure sufficient ventilation. Note: When cooling is enabled, heat is dissipated on sides of unit resulting in side temperatures of 35 to 55 C. To prevent heat build up within the unit, do not install it where it will be exposed to strong sunlight, nor near radiators, furnaces, or other sources of heat. Do not install the incubator where flammable or corrosive atmospheres may exist. 1. Remove Caster Kit, Shelves and Instructions from inside chamber. 2. Remove 4 bolts in bottom of wooden shipping pallet, which hold the incubator to the pallet. If the adjustable feet are to be used, screw them back into same holes. If the optional casters are desired, then refer to the Caster Assembly instructions included in the Caster Kit. 3. Remove all protective tape from doors and shelves. 7

8 UNPACKING AND INSTALLATION Shelf Shelf Alignment Peg Shelf Clip 4. Remove kick grill at bottom-front of incubator, check that drip pan is resting on its support bracket and that front and back drain hoses, from the chamber, empty into pan. Replace grill. 5. Place 4 shelf clips at each shelf location then install the shelf. Note that the shelves have alignment peg on the bottom, that go between the shelf clips. (See picture at left). The two shorter shelves go at the top, while the two longer shelves go at the bottom. 6. Uncoil line cord from rear of unit. Connect the plug to a power outlet that complies with the electrical requirements specified on the unit's label and with proper safety ground connection. If line cord replacement is necessary, use CSA type SJT, 14 GA, 3 conductor with NEMA 5-20P plug. Chart Recorder Activation (Model 304R) The chart recorder is configured for a temperature range of 50 C to +50 C and has the 9V battery installed. Refer to the Chart Recorder manual for details. 1. Remove any tape used for shipping, replace chart paper if necessary. 2. With power to incubator on, press 1/0 power switch on the recorder, the recorder arm should begin to move to the correct chamber temperature. Note If other recorder settings are desired or 9V battery needs replaced refer to the chart recorder instruction manual. 3. If desired, the chart day may be synchronized to current day and time. 4. Press Pen Home button, once the pen reach home position, press the Chart Rotation button to advance the chart to the present day and time. 5. Press the Pen Home button again to begin recording. Installation of Caster Refer to CASTER ASSEMBLY instructions in Caster Kit 8

9 Controls Keyed Power ON/OFF Switch: Located on back wall at bottom of chamber, is used to turn power (1) ON or (0) OFF to entire unit. Alarm On/ Off Switch: Located on front panel, is used to enable or disable alarm. Alarm Test Push Switch: Located on front panel, is used test alarm and batteries. Keys: Located on front panel. MENU - Used to access controller menus. SET - Used to display and change settings. INCREASE setting. DECREASE setting. Display and Indicators Controller Display: (Front Panel) Displays chamber and set point temperatures in C and prompts from menu. Controller Indicators: (Front Panel) Delay: Lit when delay start timer for compressor is timing. Will begin timing when power is first applied or when cooling compressor is turned off. Safety: Indicates that the chamber temperature is not within limits and the safety relay is opened. Cool: Lit when cooling compressor is on. Heat: Lit when controller demands heat. Alarm Indicators: (Front Panel LED and Beeper) Indicates that the chamber is 5 C or more above or below the setpoint temperature or that the power has failed. 9

10 Operation General Function Checks Perform this procedure if incubator is new or hasn't been operated for a long period of time. 1. Apply power by placing the Power ON/ OFF switch (Located inside chamber) to I (ON) position. The Controller, on front of door, will display L, then, 88.8 (to test display), then begins reading actual chamber temperature. Note: When power is first applied, if display indicates S instead of L, a switch setting on the controller must be changed. Refer to Replacing Temp Controller TC1. 2. After 3 seconds, the Safety LED on the controller should extinguish and the safety relay will close applying power to the heater, fan, compressor relay and convenience outlet. 3. Press and hold MENU key, after 3 sec. the display will indicate CAL. Release and press MENU again to display Pct, press SET, display should indicate 100. Press and release MENU again to indicate Pro, press SET, display should indicate 00, press and release MENU to return to normal control mode. Press SET to display control setpoint, display should read If the control setpoint or any of the other parameters aren't set correctly, use the or keys while pressing SET to change the setting. 4. The DELAY LED will be lit for 7 minutes after power is first applied, the COOL LED will be out during this delay period. When the DELAY LED goes out, the COOL LED will light and the compressor relay will close starting the compressor. 5. Allow unit to stabilize for 1 hour at 25 C, to ensure that all systems are functioning. 10 Controller Operation Usually the only controller setting that is necessary to change is the chamber temperature control setpoint. Other parameters of the controller may be changed by accessing them through the menu key, covered later.

11 OPERATION Changing Chamber Temperature Control Setpoint 1. The chamber temperature is continuously displayed, unless a key is pressed. 2. To display the setpoint temperature, press the SET key. The setpoint temperature will remain on the display for 1 sec. after the SET key is released. 3. To change the setpoint temperature, press and hold SET while pressing the or keys (Note that when either or keys are first pressed, the display will begin to change slowly at first, then increase change rate after a few seconds.) 4. Select the desired chamber setpoint then release all keys. The controller display will revert back to actual chamber temperature after a few seconds. Allow up to an hour for unit to stabilize at the new setpoint temperature. After the incubator temperature has stabilized, place samples into incubator chamber. For best results, arrange samples evenly throughout the chamber. Liquid samples should be covered to prevent evaporation and eventual frost build up on evaporator coils, particularly when operating below ambient. The Large Capacity Refrigerated Incubator has an internal 2 amp. convenience outlet inside chamber to operate devices such as: shakers, rotators, photosynthesis lights, recording thermometers etc. 11

12 OPERATION Accessing Controller Menus The temperature controller has three menu selections that can be accessed by pressing and holding the MENU key for 3 seconds. To access menu parameter, press and hold the SET key. To change the parameter, use the or keys. CAL Menu- Calibration Menu is used to change the temperature offset value to correct for differences in chamber temperature and the displayed temperature. Range -5 to 5 C. See Calibration Procedure. Pct Menu- (Percent Cooling Menu) Used to select one of three cooling modes: 100% Mode- Compressor runs continuously which provides high precision control (+/-0.5 C stability) over entire temperature range. Requires manual defrosting. 50% Mode- Compressor runs approximately half the time, which conserves power and also prevents and eliminates frost buildup inside chamber. This method eliminates the need for manual defrosting but provides less temperature stability (+/- 1.5 C). 00% Mode- Compressor is completely off. This mode is ideal for incubating samples at temperatures 10 C or higher above ambient (35 C to 50 C). It provides the greatest power savings, yet still maintains the advertised stability. Pro Menu- Protection Menu - Used to select the Protection mode of operation that determines when the alarm is activated and if the control setpoint can be changed. Range 0.0 to Mode- Normal mode that allows the user to change setpoint. Safety activates if chamber temperature (Chamber) and setpoint temperature (Setpoint) are as follows: Chamber 15.0 C and chamber < (Setpoint -6) or Chamber 40.0 C and chamber > (Setpoint +6) While SAFETY is activated, the safety relay is opened interrupting power to the heater, fan, convenience outlet and compressor. When chamber temperature returns to acceptable limits, the SAFETY will automatically terminate 12

13 OPERATION and power is reapplied. In order to allow changing of setpoint and eliminate nuisance alarms, a SAFETY by-pass takes effect when the setpoint is changed or when power is first applied. The SAFETY by-pass works as follows: Present chamber temperature is stored as a nominal safety temperature (nominal). If Chamber < Setpoint then SAFETY = nominal -2. If Chamber > Setpoint then SAFETY = nominal +2. If chamber should go beyond SAFETY then the SAFETY will activate. This SAFETY by-pass is active until chamber reaches setpoint ±1 C. 0.1 Mode- Same as 0.0 Mode, except that the setpoint is locked and can't be changed. Alarm The alarm beeper and LED are activated any time the chamber temperature goes beyond 5 C above or below the set point except when power is first applied or if the set point is changed. When activated the alarm will beep and LED light every 3 sec. The alarm may be disabled with alarm on / off switch. The alarm will also activate if power should fail. The alarm board has relay contacts that can be wired to a remote dialer or alarm system. The contacts are C Common, NO Normally Open and NC Normally Closed, with.25 push-on terminals. The NC contact will remain open under normal operating conditions, but when the alarm is activated, the contacts will delay for 25 sec then close. Alarm Relay contacts are rated 125VAC. Wire to alarm NC and C terminals as follows: 1. Disconnect incubator from power source. 2. Open front panel bezel by removing 4 screws (8 on Model 304R) in top and bottom of bezel, carefully hang bezel from brackets using wire ties or other temporary means. 3. Remove the plastic hole plug on the right side of the controller bezel to route cable. 4. Locate Alarm PC board and terminals, wire the alarm board C terminal to terminal 4 of the alarm on/off switch. Wiring the alarm through the switch will allow the remote alarm to be disabled when the alarm on/off switch is in the off position. 13

14 OPERATION 5. Connect push-on terminals from your alarm cable to alarm NC terminal and terminal 5 of alarm on/off switch. Safety Thermostat As an added safety feature, the incubator has a thermostat in the heater compartment that limits the upper chamber temperature to 65 C in the event that all other controls fail. 14

15 Maintenance Warning To reduce the risk of electric shock, disconnect from power source before servicing. Before re-applying power, after maintenance is complete, check to ensure that safety ground is intact and making a good connection. Cleaning Warning! Do not attempt to clean the incubator while the unit is plugged into a power source. Immediately clean all spilled materials from the incubator and wipe dry. If necessary, moisten a cloth with soap and water and clean inside and out. Do not use any harsh chemical cleaners. Defrosting Periodic defrosting may be necessary depending on operating temperature, ambient humidity, moisture from samples and cooling mode. Time between defrosts may be from 30 days to years. Suggested Defrost Methods Method I: For control setpoint down to 10 C, this method is the least disruptive, if samples can withstand temperature stability of +/- 1.5 C for 24 hours. Samples may remain in chamber during this procedure. 1. (Refer to Accessing Controller Menus) Press and hold MENU key until CAL is displayed, then release and press MENU again until Pct is displayed. 2. Select 50 in the Pct menu then press MENU key twice to return control mode. 3. Allow incubator to remain in this mode for about 24 hours or until frost disappears. 4. Use the MENU key to re-establish the previous selection for Pct (i.e. 100). Method II: 1. Remove any samples that may be damaged by temperatures up to 35 C. 2. Refer to Accessing Menu section of manual and set Pct parameter to Place Setpoint to 35.0 C. 15

16 MAINTENANCE 4. Allow temperature to stabilize, for 1 hour. 5. After 1 hour, remove power from unit. Open door and wipe up any excess moisture on floor of chamber with paper towels or sponge. 6. Apply power and set desired operating parameters back into controller. After chamber temperature stabilizes, place samples previously removed back into unit. Calibration If it becomes necessary to calibrate temperature controller, perform the following: 1. Place an accurate temperature measuring device in the geometric center of the chamber. 2. Set the controller to the desired operating temperature in 100% cooling mode and allow 2 hours stabilization. 3. Note the chamber temperature on the controller display and the temperature at the geometric center. 4. Subtract the chamber display reading from the geometric center reading. 5. Enter into the Calibration Mode as described in Accessing Menu. 6. Press and hold SET key, using the or keys, set the calibration parameter to the value determined in step Allow unit to stabilize for 1 hour and check that controller value and geometric center value agree ±0.5 C. Repeat calibration if necessary. 16

17 Repair Alarm and Alarm Battery Test The alarm is battery backed so that if power is lost the alarm will beep and LED will light at 3 sec. Intervals. The alarm will also be triggered if the chamber temp deviates +/- 5 C from setpoint. When the Alarm Test Button, located on the front panel is pushed and held, the alarm is triggered and alarm power is switched to the battery. The alarm should begin within 10 sec as test button is held. Note that the Alarm On/ Off switch on the front panel must be On. If the alarm fails to activate, refer to Replacing Alarm Batteries. ORN Replacing Alarm Batteries 1. Disconnect incubator from power source. 2. The batteries for the alarm are located inside the front panel mounted on the door labeled Battery. 3. Turn the thumbscrew counterclockwise, then rotate the door down. 4. Note the direction of the old batteries, then pop them out and replace with four 1.5V, AA, alkaline batteries. Replacing Temperature Controller, Alarm or S2 1. Disconnect incubator from power source. 2. Open front panel bezel by removing 4 screws (8 17

18 REPAIR on Model 304R) in top and bottom of bezel, carefully hang bezel from brackets using wire ties or other temporary means. 3. Remove 4 screws that mount controller to mounting bracket. 4. Note wire colors and positions on TB1, TB2 and TB3, then remove all wires from old controller. 5. Locate switch DS1 on lower left corner of new controller and set the switches as follows: Set DS1-1 (A) to on (down). Set DS1-2 (B) to off (up). 6. Attach wires previously removed from old controller to new controller. 7. Mount new controller and bezel, then apply power. 8. Refer to Calibration section of this manual, to calibrate new controller. Replacing RTD Temperature Sensor 1. Disconnect incubator from power source. 2. Refer to Replacing Temperature Controller, but only remove sensor wires from TB2. 3. Open incubator door and remove sensor from clip on door panel. 4. Remove old sensor, then place new sensor on bracket. 5. Connect new sensor wires to controller then mount controller and bezel. 6. Apply power, then refer to Calibration section. 18

19 REPAIR Replacing SSR1, K1, K2, T1, or T2 (Model 304R): 1. Disconnect incubator for power source. 2. Remove 8 screws from back panel then rotate back panel from top. 3. Locate device to be replaced on back panel, then remove mounting screws. 4. Unplug quick connect terminals, noting positions. 5. Place quick connects on new device and mount on panel. (Note, T2 connections must be cut then spliced.) 6. Replace back panel, then apply power. 7. Refer to General Functional Checks in the Operation section to ensure that new device is operating. Replacing FANs or THM1: 1. Disconnect incubator from power source. 2. Remove shelves from chamber area. 3. Remove 6 screws from fan panel at top-rear of chamber. 4. Rotate fan panel down to expose components. 5. Replace desired part, then coat electrical connections with RTV102 or other electrical insulator. 6. Re-assemble in opposite order as previously described. Be sure to install gaskets on either side of fan panel. 7. Apply power, refer to General Functional Checks in the Operation section to ensure that new device is operating. 19

20 REPAIR Replacing Keyed On/ Off Switch or Convenience Outlet 1. Disconnect incubator form power source. 2. Remove cover from weatherproof switch/ outlet box mounted on inside back wall of chamber. 3. Remove screws that secure defective component, then remove wire connections. 4. Replace defective component then reassemble. Replacing Chart Recorder (Model 304R): 1. Remove 4 screws that secure chart recorder, then pull recorder out of front panel. 2. Unplug thermocouple sensor from recorder. 3. Cut black and black/white power wires from old chart recorder. 4. If desired, the chart recorder thermocouple sensor may be replaced or the old sensor may be used. 5. Cut the power wires on new chart recorder about 24 from recorder, then splice new recorder into wires previously cut. Make sure that black goes to back and black/ white goes to black/ white. 6. The transformer T2 located on the back panel may also need replaced. Cut the wire length to 24 from T2 then refer to Replacing SSR1, K1, K2, T1, or T2. 20

21 Accessories and Replacement Parts Accessories Shelf, Small, Fits in upper section S Shelf, Large, Fits in lower section L Drip Pan for condensation P MODEL 304R only) Recorder Paper -50 to 50 F/C Recorder Paper 0 to 50 F/C Recorder Pen, Red Replacement Parts TC1 Controller PC Board Alarm PC Board Sensor, RTD SSR1 Solid State Relay K1 Safety Relay K2 Compressor Relay T1 Transformer THM1 Safety Thermostat S1 Keyed Power Switch S2 Alarm On/ Off Switch F1 Fuse, 20A, 125V, Slow-Blow,3AB F2 Fuse, 2A, 125V, 3AG Shelf Support Clip Trivet, Floor Rack Light, 40W, Shatter Proof Caster with brake Caster without brake Chart Recorder, Temperature Compressor SPN SPN SPN88613 SPN88616 SPN SPN SPN88678 SPN88612 SPN SPN SPN SPN09562 SPN SPN SPN SPN SPN SPN SPN * Model 304R only 21

22 Troubleshooting Symptom Possible Cause Possible Solution to Condition Incubator controller isn t functioning, Power switch isn t ON Place Power ON/ OFF switch inside no lights etc. or no power to unit. chamber to ON. Check power outlet by plugging a known good device into it. Erratic temperature display Frost buildup. Look for frost Defrost per instructions. If possible readings above or below set point. inside chamber around operate in 50% Cooling Mode to avoid evaporator. frost buildup. Temperature uniformity in chamber Frost buildup or airflow Defrost per instruction. If airflow above specified limit. blocked by samples. blocked by sample containers, remove some to allow top to bottom airflow. Temperature readings too high or too Controller may need Refer to CALIBRATION section of this low compared to thermometer. to be calibrated. manual. Control goes into power on reset Inadequate line power. If line voltage is < 106 VAC while unit is sequence while operating. Test Line voltage of outlet running, then a higher capacity AC line to Incubator while unit is is required. operating. Compressor not operating while Compressor stalled and If line voltage is < 106 VAC while unit is COOL LED is lit. thermal overloads opens. running, then a higher capacity AC line Test line voltage of outlet is required. while operating. Temperature readings go far Open heater or heater Unplug unit from power then refer to below setpoint and trigger alarm control relay SSR1. replacing HTR1. Check heater with at 15 C. OHM meter, about 29 ohms. Temperature readings go far above Defective cooling relay, If compressor isn t running while Cool setpoint and triggers alarm at 40 C compressor or shorted LED is on then replace K2 relay. If or above. heater SSR1. Check if compressor is running and evaporator compressor is running, isn t cold then cooling system needs if so touch evaporator in repair. If evaporator is cold then SSR1 chamber, it should be cold. may be shorted. Controller display works but heater, Safety relay K1 not closing. K1 relay may need replaced. compressor and chamber fan don t. Display EEE/99.9 & Alarm 1 Open sensor or sensor Check sensor connection at controller. connection. Check sensor with ohm meter, 100 ohms at 0 C and 110 ohms at 25 C. Display EEE/99.8 & Alarm 1 Shorted sensor or Check sensor connection at controller. connection. Display EEE/temp & Alarm 1 Incubator needs defrosted See erratic temperature display readings. 1. Temp Limit = Temp (+/-6 C or more from setpoint) & (> 40 C or <15 C), safety relay opens. 2. Temp Alarm = Temp is +/-5 C or more from setpoint, safety relay closed, unit continues to operate. 22

23 Wiring Diagram S1 POWER OUTLET & SWITCH BOX J2 FAN 1 CHAMBER FAN 2 ORN 1 2 ORN YEL 1 2 WHT Low Temp Incubator Schematic GRN/YEL 3 RED 2 WHT F2 2 AMP 1 BLK HTR1 BLK BLK WHT BLU CHART RECORDER BEZEL ASSEMBLY 1 2 RTD SENSOR 1 0 RED 2 4 K2 1 0 BRN 4 K1 2 THM1 2 1 INTERIOR LIGHT BLK BLK SPLICE 10 LIGHT SWITCH BRN BLK FAN DOOR SWITCH BLU S2 YEL ALARM PT6 PT2 BLK ALARM PT1 RED C PT3 PT5 VIO NC NO TB2-1 TB3-1 TB1-5 TB3-2 TB2-2 TB1-7 TB1-6 TB1-4 TB1-8 * ORN * BRN * RED * BLU 2 RED + SSR1 - RED BRN 2 1 BLK BLU ORN SPLICE 4 BLK RED PT1 BLK B1 6V - PT4 ORN + TB1-3 CT1 SWITCH DS1-1 ON DS1-2 OFF (OFF IS UP) * GRN F1 20 AMP 1 BLK P1 GRN SPLICE 2 SPLICE 8 RED COMP SPLICE 5 SPLICE 3 RECORDER SENSOR TB1-1 TB1-2 MAIN CHASSIS WHT SPLICE 1 WHT WHT WHT WHT WHT RECORDER SPLICE (Model 304R) * BLK 5 T1 SPLICE 6 1 ORN COM (4) NO (2) K2 SSR K1 3 7 * = CONTROL CABLE 12VAC 7 2 WHT 3 ORN RECORDER POWER (Model 304R) TOP VIEW 4 8 TOP VIEW BLK BLK/WHT * WHT * VIO * YEL 8 4 SPLICE 7 WHT BLK BLK/WHT WHT 2 J3 3 ORN 1 GRN/YEL TOP VIEW REAR PANEL 1 5 T1 SIDE VIEW S2 REAR VIEW 23

24 Warranty Laboratory instruments and equipment manufactured by Fisher Scientific Company L.L.C. Laboratory Equipment Division (hereinafter called the Company ) are warranted only as stated below. Subject to the exceptions and upon the conditions specified below, the Company agrees, at its election, to correct by repair, by replacement, or by credit to the purchaser, any defect of materials or workmanship which develops within one year (13 months for refrigerator and freezer products) from the date of purchase by the original purchaser by the Company or by an authorized dealer of the Company provided that investigation or factory inspection by the Company discloses that such defect developed under normal and proper use The exceptions and conditions mentioned above are the following: a. The Company makes no warranty concerning components or accessories not manufactured by it, such as tubes, batteries, etc. However, in the event of the failure of any component or accessory not manufactured by the Company, the Company will give reasonable assistance to the purchaser in obtaining from the respective manufacturer whatever adjustment is reasonable in the light of the manufacturer s own warranty. b. The Company shall be released from all obligations under its warranty in the event repairs or modifications are made by persons other than its own service personnel or authorized dealer personnel unless such repairs by others are made with the written consent of the Company. c. THE COMPANY MAKES NO WARRANTY OF MERCHANTABILITY, FITNESS FOR ANY PARTICULAR PURPOSE, OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, EITHER IN FACT OF BY OPERATION OF LAW, STATUTORY OR OTHERWISE. d. The above warranty and the above obligations to repair, replace, or credit are complete and exclusive and the Company expressly disclaims liability for lost profits or for special, indirect, incidental, consequential, or exemplary damages of any nature whether attributable to contract, warranty, negligence, strict liability, or otherwise even if the Company has been advised of the possibility of such damages. e. Representations and warranties made by any person, including dealers and representatives of the Company, which are inconsistent or in conflict with the foregoing warranty shall not be binding upon the Company unless reduced to writing and signed by an officer of the Company Kerper Boulevard Dubuque, Iowa Phone: Fax:

Isotemp Low Temperature Incubator

Isotemp Low Temperature Incubator Isotemp Low Temperature Incubator Instruction Manual Model 307C Cat. No. 11-679-25C LT1883X2 11/13/06 Table of Contents Safety Information...3 Alert Signals...3 Warning...3 Caution...3 Important...3 Introduction...4

More information

SPECIFICATIONS Power Requirements: V, 9.5A, 60Hz V, 5.8A, 50Hz Including 2A for internal convenience outlet.

SPECIFICATIONS Power Requirements: V, 9.5A, 60Hz V, 5.8A, 50Hz Including 2A for internal convenience outlet. StableTemp Low Temperature Incubator Model 146E Catalog Number 39063-00(115VAC) 39063-05(230VAC StableTemp Low Temperature Incubator offers laboratories precise temperature control over the -10 C to 60

More information

VWR Collection Model

VWR Collection Model User Manual VWR Collection Model 89508-420 Refrigerated 6.1 cu ft Incubator Operating and Maintenance Manual 7003734 Rev. 0 Preface MANUAL NUMBER 7003734 0 -- 10/7/13 Original ccs REV ECR/ECN DATE DESCRIPTION

More information

Isotemp Plus General Purpose Laboratory Freezers

Isotemp Plus General Purpose Laboratory Freezers Isotemp Plus General Purpose Laboratory Freezers Catalog Numbers: 13-986-142/142R 13-986-143/143R 13-986-144/144R 13-986-147/147R 104215 Rev. A Table of Contents Introduction...3 Safety Precautions...3

More information

Isotemp Explosion-Proof Refrigerators and Freezers

Isotemp Explosion-Proof Refrigerators and Freezers Isotemp Explosion-Proof Refrigerators and Freezers Refrigerator Model 153, 153HK Freezer Model 150, 150HK 104354 9/15/06 Table of Contents Safety Information...3 Alert Signals...3 Unpacking...4 Visible

More information

TTT Digital Incubator

TTT Digital Incubator TTT Digital Incubator 135000 135000-2 Operating Instructions N2400342 Rev. 1 08/13 Table of Contents 1.0 Safety... 3 2.0 Intended Use of Product... 4 3.0 Installation... 4 3.1 Unpacking the Unit... 4 3.2

More information

Ui REFRIGERATOR SPEC SHEET

Ui REFRIGERATOR SPEC SHEET Ui REFRIGERATOR SPEC SHEET ISOMETRIC VIEW 19 7/8 20 1/2 32 3/4 FRONT VIEW NOTES: 1. CUTOUT DIMENSIONS: 20 1/2"W X 33"L X 20 3/4"D 2. CUTOUT DIMENSIONS ARE FOR REFRIGERATOR ONLY. REFER TO STAINLESS STEEL

More information

General Purpose Laboratory Freezer with Alarms

General Purpose Laboratory Freezer with Alarms General Purpose Laboratory Freezer with Alarms 316981H01 Rev. 1 2 Table of Contents Introduction...3 arning...3 Installation...4 Unpacking...4 Visible Loss or Damage...4 Concealed Loss or Damage...4 Packing

More information

Refrigerated Incubator Model and Operating Instructions

Refrigerated Incubator Model and Operating Instructions Refrigerated Incubator Model 165000 and 165000-2 Operating Instructions N2400379 - Rev. 1 08May2018 1 Contents 1. SAFETY...3 1.1. EMF INTERFERENCE...4 1. PRODUCT INFORMATION...5 1.1 INTRODUCTION...5 2.

More information

Precision Premium Ovens 3050 Series. Operation Manual & Parts List

Precision Premium Ovens 3050 Series. Operation Manual & Parts List Precision Premium Ovens 3050 Series Operation Manual & Parts List Gravity Models OV700G (Small) PR305045G, 40G & 40GCN OV701G (Medium) PR305055G, 50G & 50GCN OV702G (Large) PR305065G, 60G & 60GCN Forced

More information

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions Model No. GB-PAC-08E4 8,000 BTU Portable Air Conditioner Operating Instructions Thank you for choosing a Soleus Air Powered by Gree Portable Air Conditioner. This owner s manual will provide you with valuable

More information

InstructIon Manual KrEs EQuIPMEnt stands

InstructIon Manual KrEs EQuIPMEnt stands Instruction Manual Instruction Manual SELF-CONTAINED AND REMOTE Kairak KRES model refrigerated equipment stand units are available in many lengths from 36 to 120 inches long. These units are available

More information

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International 11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions Model No. PE4-11R-03 2006 Soleus Air International Thank you for choosing a Soleus Air Portable Air Conditioner.

More information

Incutrol/2 Regulator

Incutrol/2 Regulator 12216-08 Model 2597A Incutrol/2 Regulator Hach Company, 1986-1996. All rights. reserved. Printed in the U.S.A. 05/95 13ed 09/96 rev2 2 Table of Contents Specifications...1 General Description...2 Setup...2

More information

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com Read and Save These Instructions Horizon Galaxy - Installation and Operations Manual Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC 27505 www.horizondehumidif iers.com 1 Safety Notes: The Horizon

More information

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual For service information call 800-544-3057 Please have the following information available before calling. Information can be found on

More information

User Manual / Installation Instructions

User Manual / Installation Instructions User Manual / Installation Instructions Outdoor Refrigerator MODEL: L24REF Lynx Professional Grills 5895 Rickenbacker Rd., Commerce, CA 90040 Service: (888) 289-5969 Tel: (323) 838-1770 Fax: (323) 838-1778

More information

BOTTOM MOUNT REFRIGERATORS & FREEZERS Installation, Operation and Maintenance Instructions

BOTTOM MOUNT REFRIGERATORS & FREEZERS Installation, Operation and Maintenance Instructions BOTTOM MOUNT REFRIGERATORS & FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the Bill of Lading to

More information

INSTRUCTIONS FOR OPERATION AND CARE OF. P.O. Box 3527 City of Industry, CA, , U.S.A

INSTRUCTIONS FOR OPERATION AND CARE OF. P.O. Box 3527 City of Industry, CA, , U.S.A INSTRUCTIONS FOR OPERATION AND CARE OF GLACIERFREEZE GF-12 P.O. Box 3527 City of Industry, CA, 91744-0527, U.S.A. 800-782-7706 626-968-6681 www.whitehallmfg.com Member of 6702-488-000 August 2012 WARNING

More information

Use and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC

Use and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC Use and Care Manual Flammable Material Storage Refrigerator LRBFS06W1HC 7085 471-00 Table of Contents Table of Contents Page Please Read and Follow these Instructions... 2 California Proposition 65...

More information

Operator s Manual. IP-100 Immersion Probe Cooler

Operator s Manual. IP-100 Immersion Probe Cooler Operator s Manual IP-100 Immersion Probe Cooler 110-810 04.27.11 Table of Contents Introduction... 3 General Information... 3 General Safety Information... 3 Safety Recommendations... 4 Unpacking Your

More information

Outdoor/Commercial Refrigerator USER S MANUAL

Outdoor/Commercial Refrigerator USER S MANUAL Outdoor/Commercial Refrigerator USER S MANUAL MODEL Number:BLZ-SSRF40D IMPORTANT:READ THIS USER S MANUAL PRIOR TO CONNECTING POWER AND USE Before the refrigerator is used, it must be PROPERLY POSITIONED,

More information

BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the Bill of Lading

More information

IW-25-2 Dehumidifier Installation & Operations. Manual

IW-25-2 Dehumidifier Installation & Operations. Manual IW-25-2 Dehumidifier Installation & Operations Installation and Operation Manual Manual IW-25-1 Dehumidifier Please Read and Save These Instructions Please Read and Save These Instructions Innovative Dehumidifier

More information

Outdoor Refrigerator USER S MANUAL

Outdoor Refrigerator USER S MANUAL Outdoor Refrigerator USER S MANUAL MODEL Number:BLZ-SSRF-40DH IMPORTANT:READ THIS USER S MANUAL PRIOR TO CONNECTING POWER AND USE Before the refrigerator is used, it must be PROPERLY POSITIONED, LEVELED

More information

INSTALLATION and OPERATING. INSTRUCTIONS for. SMZP26 Series. elf-contained Freezers

INSTALLATION and OPERATING. INSTRUCTIONS for. SMZP26 Series. elf-contained Freezers S elf-contained Freezers INSTALLATION and OPERATING INSTRUCTIONS for Series ZERO ZONE Zero Zone, Inc. 110 N. Oakridge Dr. North Prairie, WI 53153-9792 1-800-247-4496 FAX: 1-414-392-6450 www.zero-zone.com

More information

CHEST FREEZER INSTRUCTION MANUAL. Model No.: EWCF5WBX EWCF7WBX

CHEST FREEZER INSTRUCTION MANUAL. Model No.: EWCF5WBX EWCF7WBX CHEST FREEZER INSTRUCTION MANUAL Model No.: EWCF5WBX EWCF7WBX To ensure proper use of this appliance and your safety, please read the following instructions completely before operating this appliance.

More information

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM LABORATORY FREE ZERS LABORATORY FREEZERS -30 O C i.series TM Horizon Series TM introduction LABORATORY FREEZERS -30 O C helmer laboratory freezers provide the following benefits: Programmable Defrost Times

More information

BLAST CHILLER / SHOCK FREEZER MODEL AP3BCF30-1

BLAST CHILLER / SHOCK FREEZER MODEL AP3BCF30-1 REV. D Cooler is Better! TM USER S MANUAL BLAST CHILLER / SHOCK FREEZER MODEL AP3BCF30-1 American Panel Corporation 5800 S.E. 78th Street, Ocala, Florida 34472-3412 Phone: (352) 245-7055 Fax: (352) 245-0726

More information

Quest CDG Dry 74. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Quest CDG Dry 74. Read and Save These Instructions. Installation, Operation and Maintenance Instructions Quest CDG Dry 74 Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate satisfaction

More information

Horizontal Bottle Cooler Installation and Operation Manual

Horizontal Bottle Cooler Installation and Operation Manual Speeds Up the Pace of Innovation Horizontal Bottle Cooler Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! TBC-50SD, 50SB/ TBC-95SD,

More information

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST www.everest ref. com Owner s Manual for models: Back Bar Coolers " Deep Back Bar Coolers Glass Door Back Bar Coolers " Deep Galss Door Back Bar Coolers " Deep Galss Sliding Door Back Bar Coolers EBB3,

More information

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Model No.: PS08-01 PS10-01 Ref: KY80 KY100 8,000/10,000/12,000 BTU Portable Air Conditioner Operating Instructions Model No.: PS08-01 PS10-01 Ref: KY80 KY100 Model No.: PS12-03 Ref: KY120 3119233 V160310 Thank you for choosing a Soleus Air Portable

More information

Oakton TEMP 9500 Advanced Multiparameter Controller

Oakton TEMP 9500 Advanced Multiparameter Controller Oakton TEMP 9500 Advanced Multiparameter Controller Models: 89800-03 & 89800-04 Oakton Instruments 625 E Bunker Ct. Vernon Hills, IL 60061, USA 1-888-4OAKTON (1-888-462-5866) info@4oakton.com Contents

More information

GENERAL PURPOSE REFRIGERATORS ABT-9R, ABT-14R, ABT-17R, ABT-20R, ABT-30R

GENERAL PURPOSE REFRIGERATORS ABT-9R, ABT-14R, ABT-17R, ABT-20R, ABT-30R GENERAL PURPOSE REFRIGERATORS ABT-9R, ABT-14R, ABT-17R, ABT-20R, ABT-30R OWNER S INSTRUCTIONS This manual describes how to operate and care for your appliance to get the best, most efficient, performance.

More information

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217 Portable Air Conditioner with Heat Pump Technology Operating Instructions 3092402 Model No.: HCB-P13HP-D Reference No.: BPD13HP V140217 Thank you for choosing a Soleus Air Portable Air Conditioner with

More information

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International 12,000 BTU Portable Air Conditioner Operating PE3-12R-03 Instructions 3092402 Model No. PE3-12R-03 2010 Soleus Air International Thank you for choosing a Soleus Air PE3-12R-03 Portable Air Conditioner.

More information

BOD INCUBATORS MODELS: LI20 Installation And Operations Manual REV 05/

BOD INCUBATORS MODELS: LI20 Installation And Operations Manual REV 05/ BOD INCUBATORS MODELS: LI20 Installation And Operations Manual REV 05/12 4861576-1 Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab

More information

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions 3092402 2006 Soleus Air International Thank you for choosing a Soleus Air Portable Air Conditioner

More information

Quest Dry 105, 155, and 205 Dual

Quest Dry 105, 155, and 205 Dual Quest Dry 105, 155, and 205 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.

More information

Isotemp Hotplates, Stirrers and Stirring Hotplates

Isotemp Hotplates, Stirrers and Stirring Hotplates Isotemp Hotplates, Stirrers and Stirring Hotplates OPERTION MNUL ND PRTS LIST LT892X 2/28/09 Catalog # Type Top Plate Size and Material Voltage 0000H Hotplate 0x0 Ceramic 20 0000S Stirrer 0x0 Ceramic 20

More information

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International 14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions 3092402 Model No. LX-140 2012 Soleus Air International Thank you for choosing a Soleus Air LX-140 Portable

More information

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Underbar Equipment Back Bars Installation and Operation Manual Please read this manual completely

More information

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner _'_j_ii_yg, CI_ ' _i_,_!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP 12,000 BTU Portable Air Conditioner Operatin! nstructions Thank you for choosing a Soleus Air Powered by Gree Portable Air Conditioner.

More information

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS DEHUMIDIFIERS 506451-01 04/2012 HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) FRONT VIEW (with alternate outlet location

More information

GL-DEH Series Portable Dehumidifier Operating Instructions

GL-DEH Series Portable Dehumidifier Operating Instructions GL-DEH Series Portable Dehumidifier Operating Instructions General Dehumidifier Information RECOMMENDED HUMIDITY LEVELS ACCORDING TO ENERGY STAR Spring/Summer: 30% - 50% Fall/Winter: 30% - 40% EMPTYING

More information

12,000 BTU Evaporative Portable Air Conditioner

12,000 BTU Evaporative Portable Air Conditioner 12,000 BTU Evaporative Portable Air Conditioner Owner s Manual Model # KY-32E Please read owner s manual carefully before operating the unit. TABLE OF CONTENTS PAGE Table of Contents. 2 Introduction....3

More information

Operating Instructions

Operating Instructions PH5-13R-35D Portable Air Conditioner with Heat Pump Operating Instructions 3092402 Item Number: LX-130 Model Number: PH5-13R-35D 201 Soleus Air International Thank you for choosing a Soleus Air PH5 Series

More information

5) Do not start or stop the unit by inserting or pulling out the power plug.

5) Do not start or stop the unit by inserting or pulling out the power plug. 3058080 V170306 PURCHASE INFORMATION Thank you for choosing a Soleus Air Portable Air Conditioner. This Owner s Manual will provide you with valuable information necessary for the proper care and maintenance

More information

Superdryer Dehumidifiers

Superdryer Dehumidifiers Superdryer Dehumidifiers Installation and Operations Manual Read and Save These Instructions Distributed Exclusively By: Air Cleaning Equipment, Inc. Broadway, NC 27505 Phone: 919-258-3330 www.aircleaningequipment.com

More information

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with

More information

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers Please read this manual completely before installing or operating this unit! BACF11 BACF15 BACRF14 Blue Air reserves

More information

Reacti-Therm I and III Heating Modules

Reacti-Therm I and III Heating Modules INSTRUCTIONS Reacti-Therm I and III Heating Modules TS-18822 TS-18824 Number TS-18822 TS-18824 Description Reacti-Therm I Heating Module (single block) Reacti-Therm III Heating Module (triple block) 2101.1

More information

Fisher Scientific Isotemp Muffle Furnace 550 Series. Instruction Manual

Fisher Scientific Isotemp Muffle Furnace 550 Series. Instruction Manual Fisher Scientific Isotemp Muffle Furnace 550 Series Instruction Manual Model 14 Catalog No: 10-550-14 & 14A Model 58 Catalog No: 10-550-58 Model 126 Catalog No: 10-550-126 Service Division (Repairs):

More information

2.4 Cu. Ft. Compact Refrigerator

2.4 Cu. Ft. Compact Refrigerator 2.4 Cu. Ft. Compact Refrigerator User s Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE USING YOUR REFRIGERATOR AND KEEP IT FOR FUTURE REFERENCE. Model MCBR240B Product Registration Thank you for purchasing

More information

FLCH4R Garage and Utility Electric Heater

FLCH4R Garage and Utility Electric Heater FLCH4R Garage and Utility Electric Heater Installation, Operation & Maintenance Instructions Model No. Volts Amps Watts BTU/HR Phase High Low High Low High Low Min Fuse Size* FLCH4R 208 17.3 8.66 3600

More information

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents - English... 1 Instruction Manual Analog, Dry Block Heater, 1 Block, HB1AL Analog, Dry Block Heater, 2 Block, HB2AL Analog, Dry Block Heater, 4 Block, HB4AL Analog, Dry Block Heater, 6 Block, HB6AL Digital,

More information

Refrigerator Freezer Installation and Operation Manual

Refrigerator Freezer Installation and Operation Manual Speeds Up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING FREEZER Refrigerator Freezer Installation and Operation Manual Please read this manual completely before attempting

More information

Dear Valued Customer:

Dear Valued Customer: Dear Valued Customer: Thank you for purchasing CARON Products & Services equipment. We appreciate your business and look forward to being your preferred supplier of controlled environment equipment products

More information

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill

More information

4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL 4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL Model No.: MCBR465S To ensure proper use of this appliance and your safety, please read the following instructions completely before operating this appliance.

More information

WatchDog NXT60. Installation and Operations Manual. Seaira Global, LLC NC Highway 50 Surf City, NC (910)

WatchDog NXT60. Installation and Operations Manual. Seaira Global, LLC NC Highway 50 Surf City, NC (910) WatchDog NXT60 Installation and Operations Manual Seaira Global, LLC 14021 NC Highway 50 Surf City, NC 28445 (910) 660-0962 Table of Contents Important Notes 2 Warranty Registration 2 Specifications 3

More information

Fisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0

Fisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0 Fisher Scientific Model 281A Vacuum Oven Installation and Operating Manual 30979 Rev. 0 Preface Models covered in this manual: Catalog numbers Models numbers Voltage 13-262-50 6288 120V 13-262-51 6289

More information

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU OPERATING INSTRUCTIONS PCR-06-01 PCR-08-01 PCR-10-01 3058080 V170223 PURCHASE INFORMATION Thank you for choosing a Chigo Portable Air Conditioner.

More information

User Manual. Commercial Chest Freezer User s Manual 360CF5, 360CF8, 360CF14, 360CF18

User Manual. Commercial Chest Freezer User s Manual 360CF5, 360CF8, 360CF14, 360CF18 Commercial Chest Freezer User s Manual 360CF5, 360CF8, 360CF14, 360CF18 11/2017 Please read the manual thoroughly prior to equipment set-up, operation and maintenance. - 1 - Installation Important!!! Please

More information

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual This owner s manual provides instructions on safe installation use, and troubleshooting assistance. Please read it carefully and save it for reference

More information

Hi-Temp Bath Installation and Operation Manual

Hi-Temp Bath Installation and Operation Manual Hi-Temp Bath Installation and Operation Manual 33827 Rev. 0 2010 Fisher Scientific Inc. All rights reserved Printed in U.S.A. Preface Models covered in this manual Catalog No. Model No. Voltage 11-481Q

More information

Air Pump Up to 800 gallons

Air Pump Up to 800 gallons Air Pump Up to 800 gallons REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. PACKAGE CONTENTS ITEM #PBPAPK40W Questions, problems, missing parts? Before returning to your retailer, call our customer

More information

Use and Care Manual with Installation Instructions

Use and Care Manual with Installation Instructions Use and Care Manual with Installation Instructions for built in wine cooler HWS 1800 7082 635-00 Table of Contents Keep these operating instructions in a safe place and pass them on to the next owner,

More information

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm Page 1 of 8 General Overview Thank you for purchasing an Ion Genesis controller. Take the time to read the instructions carefully before using this appliance. We strongly recommend that you keep this instruction

More information

Instruction Manual. Isotemp Programmable Ovens 800 Series

Instruction Manual. Isotemp Programmable Ovens 800 Series Instruction Manual Isotemp Programmable Ovens 800 Series Domestic Model 825F (Small) 13-247-825F 13-247-825FC Model 838F (Medium) 13-247-838F 13-247-838FC Model 851F (Large) 13-247-851F 13-247-851FC International

More information

User Manual. Heater/Proofer Cabinets. Models: 177HEAT1836, 177HPI1812, 177HPI1836, 177HPU1812, 177HPU1836

User Manual. Heater/Proofer Cabinets. Models: 177HEAT1836, 177HPI1812, 177HPI1836, 177HPU1812, 177HPU1836 Heater/Proofer Cabinets Models: 177HEAT1836, 177HPI1812, 177HPI1836, 177HPU1812, 177HPU1836 Please read and keep these instructions. Indoor use only. 05/2017 www.avantcoequipment.com 1 Index General Information...4

More information

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions 3046364 Model No. PE6-10R-03 2011Soleus Air International Thank you for choosing a Soleus Air Portable Air Conditioner.

More information

Quest 105, Dry155, and 205 Dual

Quest 105, Dry155, and 205 Dual Quest 105, Dry155, and 205 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.

More information

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER G-Series Cooler GCG-10 UPRIGHT COOLER Manual is for the following models: GCG-10-N33EB G-10-N33EB Instruction Manual Manual is for the following models: GCG-10-N33EB G-10-N33EB Instruction Manual GCG-10

More information

REACH-IN INCUBATOR MODEL: RI28/RI40 2/ INSTALLATION AND OPERATIONAL MANUAL

REACH-IN INCUBATOR MODEL: RI28/RI40 2/ INSTALLATION AND OPERATIONAL MANUAL REACH-IN INCUBATOR MODEL: RI28/RI40 2/13 4861573-1 INSTALLATION AND OPERATIONAL MANUAL Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab

More information

Installation and User's Manual for Refrigerator Model SCR33

Installation and User's Manual for Refrigerator Model SCR33 Installation and for Refrigerator Model SCR33 Introduction Congratulations on your purchase of a Scotsman refrigeration product. For future reference, keep this guide in a safe, accessible location. If

More information

User Manual. Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D. Commercial Reach-In Freezers: FZ-1D, FZ-2D

User Manual. Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D. Commercial Reach-In Freezers: FZ-1D, FZ-2D User Manual Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D Commercial Reach-In Freezers: FZ-1D, FZ-2D This manual contains important information about your new Admiral Craft refrigerated unit.

More information

WIRING DIAGRAM. This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900

WIRING DIAGRAM. This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900 WIRING DIAGRAM This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900 17 THANK YOU! WARRANTY INFORMATION Thank you for choosing

More information

Operation Manual. (Version 1.5.1)

Operation Manual. (Version 1.5.1) VWR symphony TM Gravity Convection General Incubator Operation Manual (Version 1.5.1) VWR symphony Gravity Convection General Incubator 414004-610, 414004-612, 414004-614, 414004-616 414004-611, 414004-613,

More information

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69 Commercial Refrigerator And Freezer User s Manual Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69 12/2015 Please read the manual thoroughly prior to equipment

More information

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. INSTRUCTION MANUAL Model Number: BLZ-SSRF130 BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. 1 TABLE OF CONTENTS REFRIGERATOR SAFETY 3 IMPORTANT SAFEGUIDES 4 PARTS AND FEATURES

More information

Undercounter Refrigerator Operation Manual

Undercounter Refrigerator Operation Manual Undercounter Refrigerator Operation Manual i.series and Horizon Series Model Group i.series Horizon Series Blood Bank ib105 (Version A) HB105 (Version A) Laboratory/Pharmacy ilr105 (Version A) HLR105 (Version

More information

Operator s Manual. Histology Bath

Operator s Manual. Histology Bath Operator s Manual Histology Bath 110-827 05.09.12 Table of Contents Introduction... 2 General Safety Information... 2 Safety Recommendations... 3 Unpacking Your Histology Bath...4 Contents...4 Components

More information

1.7 CU.FT. REFRIGERATOR INSTRUCTION MANUAL MCBR170BMD

1.7 CU.FT. REFRIGERATOR INSTRUCTION MANUAL MCBR170BMD 1.7 CU.FT. REFRIGERATOR INSTRUCTION MANUAL Model No.: MCBR170WMD MCBR170BMD To ensure proper use of this appliance and your safety, please read the following instructions completely before operating this

More information

Undercounter Refrigerator Operation Manual i.series and Horizon Series

Undercounter Refrigerator Operation Manual i.series and Horizon Series Undercounter Refrigerator Operation Manual i.series and Horizon Series Blood Bank Models i.series: ib105 (Version B) Horizon Series: HB105 (Version B) Laboratory/Pharmacy Models i.series: ilr105 (Version

More information

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V. HMT-D30-A HMT-D45E-A HMT-D70E-A Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A Portable Dehumidifier Operating Instructions 3119233 V.141217 General Dehumidifier Information RECOMMENDED HUMIDITY LEVELS

More information

This manual describes how to operate and care for your appliance to get the best, most efficient, performance. READ THIS BOOK!

This manual describes how to operate and care for your appliance to get the best, most efficient, performance. READ THIS BOOK! GENERAL PURPOSE DUAL TEMP REFRIGERATOR / FREEZER MODEL NUMBERS: ABT-RFC-3M, ABT-RFC-12M, ABT-RFC-16M, ABT-RFC-17A, ABT-RFC-20A, ABT-RFC-30M OWNER S INSTRUCTIONS This manual describes how to operate and

More information

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions OWNER S MANUAL Operating and Servicing Instructions CR13000-PAC PORTABLE AIR CONDITIONER with HEAT PUMP Portable Air Conditioner Questions or concerns? For assistance, please call Customer Service ClimateRight

More information

Reacti-Therm I and III Heating/Stirring Modules

Reacti-Therm I and III Heating/Stirring Modules INSTRUCTIONS Reacti-Therm I and III Heating/Stirring Modules TS-18821 TS-18823 Number TS-18821 TS-18823 Description Reacti-Therm I Heating/Stirring Module (single block) Reacti-Therm III Heating/Stirring

More information

Portable Dehumidifier

Portable Dehumidifier Portable Dehumidifier OPERATING INSTRUCTIONS HMT-D30-A Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A HMT-D45E-A HMT-D70E-A 3058080 V.161115 PURCHASE INFORMATION Thank you for choosing a Soleus Air Portable

More information

Owner s Manual WARMER DRAWER. (Without Water Tray) Models WD-20, WD21A, & WD-35A. WD-20 Shown MANUFACTURING NUMBERS: P/N Rev.

Owner s Manual WARMER DRAWER. (Without Water Tray) Models WD-20, WD21A, & WD-35A. WD-20 Shown MANUFACTURING NUMBERS: P/N Rev. MANUFACTURING NUMBERS: 9400130 9400132 9400134 9400136 9400140 9400142 9400144 9400146 9400150 9400152 9400154 9400156 C L I S T E D US SA L NIT A T I S T E ION D CM WARMER DRAWER (Without Water Tray)

More information

Table of Contents Welcome and Thank You Note:

Table of Contents Welcome and Thank You Note: TWR210EBL/TWR215ESS TWR320EBL/TWR325ESS Thermoelectric Wine Cooler Owner s Manual This owner s manual provides instructions on safe installation, use, and maintenance. Please read it carefully and save

More information

USE & CARE GUIDE. MED2 Series REFRIGERATORS & FREEZERS FOR MEDICAL & LABORATORY STORAGE

USE & CARE GUIDE. MED2 Series REFRIGERATORS & FREEZERS FOR MEDICAL & LABORATORY STORAGE USE & CARE GUIDE MED2 Series REFRIGERATORS & FREEZERS FOR MEDICAL & LABORATORY STORAGE If you need service or call with a question, please have this information ready. We advise you to keep this Use &

More information

Product Information and Technical Guide

Product Information and Technical Guide Product Information and Technical Guide Side by Side and Top Mount Refrigerators July 2003 - December 2003 White-Westinghouse 5995540384 January 2004 TABLE OF CONTENTS Safe Servicing Practices ------------------------------------------------------------------------------------------

More information

PREMIER CUBE FREEZERS, UNDERCOUNTER FREE STANDING & MID-SIZE REFRIGERATORS

PREMIER CUBE FREEZERS, UNDERCOUNTER FREE STANDING & MID-SIZE REFRIGERATORS PREMIER CUBE FREEZERS, UNDERCOUNTER FREE STANDING & MID-SIZE REFRIGERATORS 1 cu.ft, 2 cu.ft., 4 cu.ft. 5 cu.ft, & 10 cu.ft. W/ Gen II Controller OWNER S INSTRUCTIONS This manual describes how to operate

More information

OWNER S GUIDE. Undercounter & Mid-Size Laboratory Refrigerator & Freezer with Temp Display System V5.2. Table of Contents

OWNER S GUIDE. Undercounter & Mid-Size Laboratory Refrigerator & Freezer with Temp Display System V5.2. Table of Contents OWNER S GUIDE Undercounter & Mid-Size Laboratory Refrigerator & Freezer with Temp Display System V5.2 Table of Contents RECEIVING AND SHIPPING DAMAGE HANDLING... 2 SAFETY... 3 RELEASE OF LIABILITY... 3

More information

VWR Collection Model

VWR Collection Model User Manual VWR Collection Model 10753-894 Refrigerated Incubator - Microprocessor Controlled Operating and Maintenance Manual 7013733 Rev. 0 Preface Manual Number 7013733 0 40096 4/3/15 Original - cabinet,

More information

Use and Care Manual. For Beverage Cooler RU

Use and Care Manual. For Beverage Cooler RU Use and Care Manual For Beverage Cooler RU 500 7081 619-01 Congratulations on your purchase. Choosing this appliance means you want all the benefits of state-of-the-art refrigeration technology, guaranteeing

More information

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products, Inc. 700 Thimble Shoals Blvd, Suite 109 Newport News, VA. 23606-2575 Tel: (757) 873 6800 Fax: (757) 873 3632

More information