WALL ESCUTCHEON PIPE SEAL WITH APPROVED FIRE CAULKING (SEE SPECIFICATIONS) NOTE: 12" 12" 24"
|
|
- Lionel Singleton
- 6 years ago
- Views:
Transcription
1 SOUTH TEJON ST., SUITE 00 COLORADO SPRINGS, CO. 00 TELE.: FAX: WALL ESCUTCHEON PACK ANNULAR SPACE WITH MINERAL WOOL GENERAL NOTES. THIS PROJECT INCLUDES THE DESIGN AND PROVISION OF A NEW WET SPRINKLER SYSTEM THROUGHOUT THE UNSPRINKLERED PORTIONS OF THE BUILDING INDICATED ON THE FOLLOWING DRAWINGS.. THE ARCHITECTURAL BACKGROUND PROVIDED ON THESE SHEETS IS FOR GENERAL REFERENCE ONLY. CONTRACTOR SHALL VERIFY ALL BACKGROUNDS WITH ARCHITECTURAL SHEETS AND SITE VISIT.. SYSTEM DESIGN TO BE PER NFPA, 00 EDITION AND THESE DRAWINGS AND SPECIFICATIONS. SKYLIGHT 0" GYP BOARD " ROOF STEEL STUD SEAL WITH APPROVED FIRE CAULKING (SEE SPECIFICATIONS) WALL ESCUTCHEON HOLES THROUGH WALLS SHALL BE A MINIMUM OF IN. LARGER, AND MAXIMUM OF IN. LARGER IN DIAMETER THAN THE OUTSIDE DIAMETER OF THE PASSING THRU THE RATED WALL. THIS SPACE SHALL BE FILLED WITH MINERAL WOOL AND SEALED WITH AN APPROVED LISTED FIRE CAULK OR SEALANT. ALL PENETRATIONS OF FIRE RATED WALLS AND ASSEMBLIES SHALL BE UL LISTED FOR THAT PURPOSE, FOR BOTH THE TYPE OF MATERIAL AND WALL OR CEILING/FLOOR CONSTRUCTION. LISTED ALTERNATE METHODS WILL BE ACCEPTED.. CONTRACTOR SHALL OBTAIN SIGNED OWNER S CERTIFICATE AS PER NFPA AND SPECIFICATIONS.. REFER TO SPECIFICATIONS SECTION 00 FOR ADDITIONAL INFORMATION REGARDING THE FIRE PROTECTION SYSTEM.. SEE PROJECT SPECIFICATIONS FOR SYSTEM TESTING REQUIREMENTS (HYDROSTATIC, TRIP TESTING ETC.).. PIPING:.. SPRINKLER CONTRACTOR SHALL COORDINATE LOCATION OF ALL PIPING AND SPRINKLERS WITH OTHER TRADES, HVAC SYSTEMS IN PARTICULAR. COORDINATION SHALL OCCUR DURING DESIGN AND LAYOUT, AS WELL AS IN THE FIELD... SPRINKLER PIPING SHALL BE ROUGHED IN PRIOR TO OR CONCURRENTLY WITH THE INSTALLATION OF MAJOR DUCTWORK. INSTALLATION OF SPRINKLERS BELOW OBSTRUCTING DUCTWORK MAY OCCUR LATER... SIZING AND ACTUAL ROUTING OF ALL NEW SPRINKLER SYSTEM PIPING IS THE RESPONSIBILITY OF THE CONTRACTOR AND SUBJECT TO APPROVAL BY THE ENGINEER... WET SYSTEM PIPING AND FITTINGS SHALL MEET THE REQUIREMENTS OF NFPA, EXCEPT THAT PRESS FIT AND POZ LOK SYSTEMS ARE NOT APPROVED FOR THIS PROJECT... ALL PIPING INCH AND LARGER TO BE SCHEDULE 0 STEEL; ALL PIPING INCH AND SMALLER TO BE CPVC EXCEPT AS NOTED BELOW:... ALL EXPOSED PIPING TO BE SCHEDULE 0 STEEL.... ALL LOCATIONS NOT LISTED FOR CPVC SHALL BE SCHEDULE 0 STEEL.... WHERE SUNLIGHT, CHEMICALS, OR PHYSICAL ABUSE COULD BE EXPECTED, ONLY SCHEDULE 0 STEEL SHALL BE USED... PIPING PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED IN ACCORDANCE WITH SPECIFICATIONS (SEE ALSO DETAIL /F00)... PAINTING OF TO BE BY DIVISION. Pyramid Court, Suite 00 Englewood, CO 0 Phone: Fax: 0..0 LIGHT COVE CEILING SPACE CEILING SPACE GRID CEILING. HANGERS:.. HANGERS, HANGER RODS, CLAMPS, AND INSERTS SHALL BE IN ACCORDANCE WITH NFPA, 00 EDITION... CPVC HANGERS SHALL BE IN ACCORDANCE WITH MANUFACTURER S GUIDELINES. SEE DETAIL /F00... TRAPEZE STYLE HANGING ASSEMBLIES MAY BE USED, BUT ONLY WITH DOCUMENTATION ON THE SHOP DRAWINGS VALIDATING THE SIZING OF THE TRAPEZE MEMBERS. WHEN A TRAPEZE MEMBER IS NOT EXPLICITLY LISTED IN NFPA (E.G. UNISTRUT), DOCUMENTATION MUST BE PROVIDED THAT INDICATES ADEQUATE SECTION MODULUS AND OTHER PERTINENT PARAMETERS ARE BEING MET.. SPRINKLERS:.. PROTECTION OF SPRINKLERS DURING PAINTING, AND REMOVAL THEREAFTER, SHALL BE BY DIVISION... UNLESS INDICATED OTHERWISE, ALL AUTOMATIC SPRINKLERS LOCATED WITHIN SUSPENDED TILE CEILINGS SHALL BE, RECESSED TO MATCH EXISTING SPRINKLERS. UNLESS OTHERWISE NOTED, REMAINING EXPOSED SPRINKLERS SHALL BE. SEE SPRINKLER LEGEND FOR SPRINKLER TYPE DETAILS... SPRINKLERS SHALL BE LOCATED IN THE CENTER OF TILE. SEE DETAIL /F00... HEAD GUARDS LISTED FOR USE WITH THE RESPECTIVE SPRINKLERS SHALL BE INSTALLED ANYWHERE EXPOSED SPRINKLERS ARE LOCATED BELOW 0" AFF... ELECTRICAL AND MECHANICAL ROOMS SHALL UTILIZE INTERMEDIATE TEMPERATURE RATED SPRINKLERS. " " 0. WATER SUPPLY DATA: CONTRACTOR SHALL BASE HYDRAULIC CALCULATIONS ON THE FOLLOWING WATER SUPPLY INFORMATION: 0.. STATIC: 0 PSI RESIDUAL: 0 PSI FLOWING: GPM 0.. TEST CONDUCTED BY : WESTERN STATES FIRE PROTECTION : 0/0/0 0.. EFFECTIVE POINT: WHERE INCH UNDERGROUND CONNECTS TO INCH UNDERGROUND MAIN. SEE SITE PLAN /F HOSE ALLOWANCES SHALL BE TAKEN AT THIS SAME EFFECTIVE POINT. " USER\PW: REED.ROISUM\M00- O:\PROJECTS\00\0.0\.0 PROJECT EXECUTION\. DESIGN - ENGINEERING\DRAWINGS\0.0 F00.DWG FEB 0 - :PM XREFS: POST- INSTALLED ANCHOR ALL THREAD ROD HANGER RING SIZE inches " ¼" ½" " ½" " SEE TABLE BELOW FOR NUMBER Hanger 0 0" TO 0" 0 0" TO " 0 0" TO 0" 0 0" TO 0" 0 0" TO 0" 0 0" TO 0 0" CONCRETE FLOOR SLAB CONCRETE TEE POST- INSTALLED ANCHOR ALL ANCHORS AND HANGERS TO BE LISTED FOR USE IN CONCRETE IN ACCORDANCE WITH NFPA, 00 EDITION. OF HANGERS REQUIRED ASTM F CPVC BRANCHLINE * Pipe Length Hangers " TO 0" " TO 0" " TO 0" " TO 0" " TO 0" 0 " TO 0 0" HANGER RING MINIMUM ALLOWABLE HANGERS PER LENGTH OF CPVC * NSF INTERNATIONAL APPROVED FOR USE WITH POTABLE WATER Hangers CLIP ANGLE " TO 0" " TO " " TO 0" " TO 0" " TO 0" 0 " TO 0 0" THE MAXIMUM DISTANCE BETWEEN HANGERS FOR LISTED NONMETALLIC SHALL BE MODIFIED AS SPECIFIED IN THE INDIVIDUAL PRODUCT LISTINGS. ALL THREAD ROD " " " " x BLANK TILES " x TILES LOCATE SPRINKLER AT CENTER OR INCHES FROM THE TWO ADJACENT GRID LINES LOCATE SPRINKLER AT CENTER OF TILE " " " " " " x SCORED TILES LOCATE SPRINKLER INCHES FROM TWO GRID LINES " EXISTING IN. UG FLOW TEST INFO: STATIC: 0 PSI RESIDUAL: 0 PSI FLOWING: GPM EXISTING HYDRANT EFFECTIVE POINT EXISTING GATE VALVE APPROX. 0 FT OF EXISTING IN. UG EXISTING HYDRANT ELEVATION = 0" FLOOR SPRINKLER CONTROLS = 0" EXISTING GATE VALVE EXISTING REMOTE YARD FDC FIRE PROTECTION SYMBOLS LEGEND OH RISER VERTICAL EXISTING SPRINKLER PIPING NEW SPRINKLER PIPING UNDERGROUND PIPING CAP BREAK ORDINARY HAZARD GROUP I AREA ORDINARY HAZARD GROUP II AREA PLAN NOTE FIRE DEPARTMENT CONNECTION (FLUSH TYPE) FIRE DEPARTMENT CONNECTION (SIAMESE TYPE) BACKFLOW TEST OUTLET UNDERGROUND GATE VALVE HYDRANT EXISTING REMOTE YARD FDC CHECK VALVE BUTTERFLY CONTROL VALVE CEILING HEIGHT ABOVE ED FLOOR. ALL AREAS WITH THIS SYMBOL: SHALL BE DESIGNED NFPA. OH. ALL AREAS WITH THIS SYMBOL: SHALL BE DESIGNED NFPA. SP. ALL AREAS WITH THIS SYMBOL: SHALL BE DESIGNED TO FLOW 0 SPRINKLERS OR ENTIRE ROOM WITH MINIMUM END HEAD PRESSURE OF PSI. SPRINKLERS TO BE.K.. ALL REMAINING AREAS TO BE DESIGNED TO LIGHT HAZARD PARAMETERS PER NFPA.. ALL HYDRAULIC CALCULATIONS SHALL INCLUDE A MINIMUM 0 PSI SAFETY FACTOR.. IN ACCORDANCE WITH FM GLOBAL GUIDELINES, AREA REDUCTIONS FOR RESPONSE SPRINKLERS, AND SITE PLAN F00 CRAGWOOD DRIVE, COLORADO SPRINGS, COLORADO 00 DETAILS FIRE PRO 0.0
2 SPRINKLER LEGEND SYMB. MFR. PLAN NOTES THD TEMP. SZ RTG. TYPE ESCUT. VK0. RECESSED PENDANT " VK0. RECESSED PENDANT " 00 VK. FLAT CONCEALED PENDANT "MIRAGE" " 00 BRUSHED VK00. UPRIGHT " 00 VK. UPRIGHT VK0. HORIZONTAL SIDEWALL " " VK0. RECESSED HORIZONTAL SIDEWALL " VK0. RECESSED HORIZONTAL SIDEWALL " 00 VK0.0 EXTENDED COVERAGE REC. HORIZ. SIDEWALL " #. PROVIDE AND INSTALL HORIZONTAL SIDEWALL SPRINKLER UNDER OPEN GARAGE DOOR.. PROVIDE INTERMEDIATE OR HIGH TEMPERATURE RATED SPRINKLERS NEAR UNIT HEATER BASED ON NFPA GUIDELINES.. PROVIDE AND INSTALL INTERMEDIATE TEMPERATURE RATED UPRIGHT SPRINKLERS IN SKYLIGHTS. SEE /F00 FOR DETAILS.. PROVIDE AND INSTALL INTERMEDIATE TEMPERATURE HORIZONTAL SIDEWALL SPRINKLER POINTING DOWN THE SLOPE IN THE APPROXIMATE LOCATION SHOWN. PIPING TO BE ROUTED AS HIGH AND TIGHT TO WALL AS POSSIBLE. ALL EXPOSED PIPING TO BE SCHEDULE 0 STEEL IN THIS AREA.. PROVIDE AND INSTALL INTERMEDIATE TEMPERATURE RATED CONCEALED SPRINKLER WITH BRUSHED COVER PLATE IN DISPLAY CASE AS SHOWN.. PROVIDE AND INSTALL INTERMEDIATE TEMPERATURE RATED RECESSED PENDANT SPRINKLER IN APPROXIMATE LOCATION SHOWN. SPRINKLER PROTECTION NOT REQUIRED IN SKYLIGHT.. PROVIDE AND INSTALL EXTENDED COVERAGE RECESSED HORIZONTAL SIDEWALL SPRINKLER IN APPROXIMATE LOCATION SHOWN. AND ESCUTCHEON TO BE.. NO WORK IN THIS AREA. EXISTING SPRINKLERS.. PROVIDE AND INSTALL INTERMEDIATE TEMPERATURE HORIZONTAL SIDEWALL SPRINKLER POINTING DOWN THE SLOPE IN THE APPROXIMATE LOCATION SHOWN. ALL EXPOSED PIPING TO BE SCHEDULE 0 STEEL IN THIS AREA. 0. ROUTE LEVEL DOWN IN CHASE IN THIS APPROXIMATE LOCATION. SP SP SPRNK K S.I.N. RSPNS NO. FCTR INSPECTOR S TEST OUTLET. NOT USED.. NO SPRINKLER PROTECTION REQUIRED BELOW NON COMBUSTIBLE EXTERIOR OVERHANG. SOUTH TEJON ST., SUITE 00 COLORADO SPRINGS, CO. 00 TELE.: FAX: Pyramid Court, Suite 00 Englewood, CO 0 Phone: Fax: CPVC PIPING NOT ALLOWED IN OR ABOVE THIS ROOM.. COORDINATE CROSS MAIN ROUTING WITH EXISTING CONDITIONS.. PROVIDE AND INSTALL CONCEALED SPRINKLER WITH BRUSHED COVER PLATE AS SHOWN.. NO SPRINKLER PROTECTION REQUIRED WITHIN CEILING POCKET. SP OH OH SP OH OH OH OH. ALL AREAS WITH THIS SYMBOL: SHALL BE DESIGNED NFPA. EXISTING HOSE CONNECTION OH. ALL AREAS WITH THIS SYMBOL: SHALL BE DESIGNED NFPA. OH. ALL AREAS WITH THIS SYMBOL: SP SHALL BE DESIGNED TO FLOW 0 SPRINKLERS OR ENTIRE ROOM WITH MINIMUM END HEAD PRESSURE OF PSI. SPRINKLERS TO BE.K.. ALL REMAINING AREAS TO BE DESIGNED TO LIGHT HAZARD PARAMETERS PER NFPA.. ALL HYDRAULIC CALCULATIONS SHALL INCLUDE A MINIMUM 0 PSI SAFETY FACTOR. USER\PW: REED.ROISUM\M00- O:\PROJECTS\00\0.0\.0 PROJECT EXECUTION\. DESIGN - ENGINEERING\DRAWINGS\0.0 F0.DWG FEB 0 - :PM XREFS:. IN ACCORDANCE WITH FM GLOBAL GUIDELINES, AREA REDUCTIONS FOR RESPONSE SPRINKLERS, AND remove head?? CRAGWOOD DRIVE, COLORADO SPRINGS, COLORADO 00 OH THIS LEVEL LEVEL LEVEL LEVEL 0 PARTIAL MAIN LEVEL DN TO LEVEL FLOOR PLAN FIRE PROTECTION LEVEL UNIVERSITY HALL BUILDING 0 KEY PLAN N.T.S. NORTH SEE /F0 FOR CONTINUATION F0
3 SPRINKLER LEGEND SYMB. MFR. S.I.N. NO. K FCTR RSPNS TYPE THD SZ TEMP. RTG. SPRNK ESCUT. VK0. RECESSED PENDANT " ROUTE UP TO LEVEL SEE SITE PLAN /F00 FOR CONTINUATION EXISTING IN. UG VK0. RECESSED PENDANT " 00 VK. FLAT CONCEALED PENDANT "MIRAGE" " 00 BRUSHED VK00. UPRIGHT " 00 VK. UPRIGHT " VK0. HORIZONTAL SIDEWALL " VK0. RECESSED HORIZONTAL SIDEWALL " VK0. RECESSED HORIZONTAL SIDEWALL " 00 VK0.0 EXTENDED COVERAGE REC. HORIZ. SIDEWALL " SOUTH TEJON ST., SUITE 00 COLORADO SPRINGS, CO. 00 TELE.: FAX: PLAN NOTES #. SPRINKLER CONTROLS. SEE DETAIL /F00.. PROVIDE AND INSTALL () NEW SPARE HEAD CABINETS. ONE HEAD SPARE CABINET TO HOLD THE REQUIRED SPARE SPRINKLERS AND ONE () HEAD CABINET TO HOUSE SPARE COVER PLATES AS SPECIFIED.. PROVIDE HORIZONTAL SIDEWALL SPRINKLER IN ELEVATOR PIT LOCATED NO MORE THAN FT UP FROM PIT FLOOR. PROVIDE FLOW SWITCH WITH VALVE ABOVE CEILING, OUTSIDE ELEVATOR SHAFT. ROUTE TEST/DRAIN PIPING TO EXTERIOR WALL AND OUT. PROVIDE SPLASH BLOCK AT EXTERIOR.. NO SPRINKLERS OR SPRINKLER PIPING ALLOWED IN ELEVATOR EQUIPMENT ROOM. Pyramid Court, Suite 00 Englewood, CO 0 Phone: Fax: PROVIDE AND INSTALL INTERMEDIATE TEMPERATURE RATED CONCEALED SPRINKLER WITH BRUSHED COVER PLATE IN DISPLAY CASE AS SHOWN.. LEVEL FLOOR CONTROLS LOCATED ABOVE CEILING. SEE /F00 FOR DETAILS.. ROUTE DRAIN PIPING TO EXTERIOR WALL IN APPROXIMATE LOCATION SHOWN. PROVIDE SPLASH BLOCK AT EXTERIOR.. NO WORK IN THIS AREA. EXISTING SPRINKLERS.. FROM LEVEL. ROUTE MAIN ABOVE CEILING TO FLOOR CONTROLS LOCATION SHOWN. 0. UP FROM LEVEL. 0. LEVEL FLOOR CONTROLS. SEE /F00 FOR DETAILS.. NO SPRINKLER PROTECTION REQUIRED BELOW NON COMBUSTIBLE EXTERIOR OVERHANG.. CPVC PIPING NOT ALLOWED IN OR ABOVE THIS ROOM.. ALL AREAS WITH THIS SYMBOL: SHALL BE DESIGNED NFPA. UP FROM LEVEL (LOWER LEVEL) OH. ALL AREAS WITH THIS SYMBOL: SHALL BE DESIGNED NFPA. SP. ALL AREAS WITH THIS SYMBOL: SHALL BE DESIGNED TO FLOW 0 SPRINKLERS OR ENTIRE ROOM WITH MINIMUM END HEAD PRESSURE OF PSI. SPRINKLERS TO BE.K. USER\PW: REED.ROISUM\M00- O:\PROJECTS\00\0.0\.0 PROJECT EXECUTION\. DESIGN - ENGINEERING\DRAWINGS\0.0 F0.DWG FEB 0 - :PM XREFS: KEY PLAN N.T.S. UNIVERSITY HALL BUILDING NORTH 0 0 DN FROM LEVEL OH OH SPRINKLERED FROM ABOVE UP TO LEVEL (MAIN/GARDEN LEVEL) SEE /F0 FOR CONTINUATION 0 LEVEL LEVEL. ALL REMAINING AREAS TO BE DESIGNED TO LIGHT HAZARD PARAMETERS PER NFPA.. ALL HYDRAULIC CALCULATIONS SHALL INCLUDE A MINIMUM 0 PSI SAFETY FACTOR.. IN ACCORDANCE WITH FM GLOBAL GUIDELINES, AREA REDUCTIONS FOR RESPONSE SPRINKLERS, AND LEVEL F0 CRAGWOOD DRIVE, COLORADO SPRINGS, COLORADO 00 PARTIAL FLOOR PLANS FIRE PROTECTION 0.0
4 SOUTH TEJON ST., SUITE 00 COLORADO SPRINGS, CO. 00 TELE.: FAX: Pyramid Court, Suite 00 Englewood, CO 0 Phone: Fax: USER\PW: REED.ROISUM\M00- O:\PROJECTS\00\0.0\.0 PROJECT EXECUTION\. DESIGN - ENGINEERING\DRAWINGS\0.0 F00.DWG FEB 0 - :PM XREFS: d d d d d a c BUTTERFLY VALVE WITH TAMPER SWITCH. CHECK VALVE b FLOOR CONTROL VALVE ASSEMBLY INCLUDING: a b c d FLOW SWITCH PRESSURE RELIEF VALVE PRESSURE GAUGE WITH WAY VALVE DRAIN TO OUTSIDE WALL TO LEVEL SPRINKLER SYSTEM TO LEVEL SPRINKLER SYSTEM FROM BELOW a c d b ABOVE CEILING SPACE LIGHT FIXTURE (TYP.) CEILING OFFICE 0 d BUTTERFLY VALVE WITH TAMPER SWITCH. CHECK VALVE FLOOR CONTROL VALVE ASSEMBLY INCLUDING: a FLOW SWITCH b PRESSURE RELIEF VALVE c PRESSURE GAUGE WITH WAY VALVE d DRAIN TO OUTSIDE WALL TO LEVEL SPRINKLER SYSTEM ABOVE CEILING SPACE LIGHT FIXTURE (TYP.) OFFICE 0 d d EXISTING IN. UNDERGROUND WATER LEAD IN. 0 EXISTING IN. UNDERGROUND WATER LEAD IN. 0 EXISTING IN. MAIN. EXISTING IN. 000SS AMES BACKFLOW ASSEMBLY EXISTING MAIN DRAIN EXISTING FLOW SWITCH EXISTING PRESSURE GAUGE EXISTING SYSTEM BUTTERFLY CONTROL VALVE EXISTING WET SYSTEM EXISTING FDC PIPING EXISTING FDC CHECK VALVE EXISTING STAND PIPING NEW BUTTERFLY VALVE WITH TAMPER SWITCH NEW WET SYSTEM. PROVIDE AND INSTALL () NEW SPARE HEAD CABINETS ON WALL NEAR SPRINKLER CONTROLS. ONE HEAD SPARE CABINET TO HOLD THE REQUIRED SPARE SPRINKLERS AND ONE () HEAD CABINET TO HOUSE SPARE COVER PLATES AS SPECIFIED. EXISTING IN. MAIN. EXISTING IN. 000SS AMES BACKFLOW ASSEMBLY EXISTING MAIN DRAIN EXISTING FLOW SWITCH EXISTING PRESSURE GAUGE EXISTING SYSTEM BUTTERFLY CONTROL VALVE EXISTING WET SYSTEM EXISTING FDC PIPING EXISTING FDC CHECK VALVE EXISTING STAND PIPING F00 CRAGWOOD DRIVE, COLORADO SPRINGS, COLORADO 00 DETAILS FIRE PRO 0.0
5
COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM
SECTION 21 10 00 PART 1 - GENERAL 1.1 CODES A. Work shall conform to NFPA 13 Sprinkler Systems, 2002 Edition and NFPA 24 Outside Protection, 2002 Edition. NFPA 14 Standpipe Systems, 2000 Edition and International
More informationCubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM
SECTION 21 0000 AUTOMATIC FIRE SPRINKLER SYSTEM PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Codes and Standards: 1. FBC (Florida Building Code 2015) 2. FBC (Florida Fire Code 2015) 3. NFPA #13R (Standard for
More informationC. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.
SECTION 218800 - FIRE PROTECTION 1. GENERAL A. Provisions of Division 1, GENERAL REQUIREMENTS, and Section 230000, MECHANICAL GENERAL CONDITIONS, and Section 230050, SEISMIC PROTECTION are a part of this
More informationEnvironmental Health & Safety
Environmental Health & Safety Oklahoma State University FIRE SPRINKLER SYSTEM STANDARD Environmental Health and Safety University Health Services Suite 002 Stillwater, OK 74078 (405) 744-7241 www.ehs.okstate.edu
More informationMONTECITO FIRE PROTECTION DISTRICT
Section 5a MONTECITO FIRE PROTECTION DISTRICT FIRE PROTECTION PLAN Residential Automatic Fire Sprinkler System Installations I Automatic Fire Sprinkler System Standards 1. Definition and Standard: An automatic
More informationGas Station & C Store SECTION CWM Job No
SECTION 21 1300 - PART 1 - GENERAL 1.1 WORK INCLUDED A. Provide labor, materials, equipment and services to perform operations required for the complete installation and related Work as required in Contract
More informationFIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.
15500 - FIRE PROTECTION PART I DESIGN GUIDELINES A. General 1. Vertical fire pumps shall not be used at the University. 2. coupling piping shall be permitted for sprinkler and standpipe systems only. B.
More informationFIRE SUPPRESSION SPRINKLER SYSTEM
PART 1 GENERAL 1.01 DESCRIPTION A. The provisions of the General Requirements, Supplementary Requirements, and Division 1 apply to the plumbing work specified in this Division. B. The requirements of this
More informationFIRE SPRINKLER SYSTEMS POLICY
FIRE SPRINKLER SYSTEMS POLICY Revised 1/1/17 DESIGN AND SUBMITTAL REQUIREMENTS All new and existing fire sprinkler systems within the jurisdiction of the City Fire Department shall meet all of the applicable
More informationA. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:
SECTION 21 13 13 WET-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
More informationNew Construction Fire Inspection Process
New Construction Fire Inspection Process This document is intended to provide the Owner, Designer, and/or Contractor of new construction with an outline of required fire inspections and with the specific
More informationSECTION WET-PIPE SPRINKLER SYSTEMS
SECTION 21 13 13 WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SCOPE OF WORK A. Design, installation and testing shall be in accordance with NFPA 13 except for specified exceptions. B. The demolition
More informationWest District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8
City of Ottawa Project No. CR006230 Page 1 of 8 PART 1 - GENERAL 1.1 Reference Standards.1 Conform to the following:.1 Provincial and municipal building and fire regulations as approved by Provincial Fire
More informationDIVISION 21 - FIRE SUPPRESSION
DIVISION 21 - FIRE SUPPRESSION DESIGN CRITERIA It is the policy of UC Davis to install fire sprinkler systems in all new construction/facilities. If the building is classified as a pole barn, shed, carport,
More informationFIRE SPRINKLER SYSTEMS POLICY
FIRE SPRINKLER SYSTEMS POLICY VERSION 1.012/2015 FIRE SPRINKLER SYSTEMS Design and Submittal requirements All new and existing fire sprinkler systems within the jurisdiction of the City of San Mateo Fire
More informationUC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS
DIVISION 21 - FIRE SUPPRESSION Includes the following sections: None DESIGN REQUIREMENTS It is the policy of City of Santa Cruz to install fire sprinkler systems in all new construction/facilities. If
More informationSECTION SPRINKLER SYSTEMS
SECTION 15325 SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Wet-pipe sprinkler systems. B. Preaction sprinkler systems. C. System design, installation, and certification. D. Fire department
More informationB. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.
DIVISION 21 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, sleeves, escutcheons, seals, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS
More information2. Welding Materials and Procedures shall conform to the ASME Code.
PART 1 GENERAL 1.01 Scope of Standard A. The design guidelines contained herein include the requirements for systems, materials, fittings and valves utilized for fire protection systems at Sam Houston
More informationPort of St Helens SIA Aircraft Hanger Scappoose, OR
Port of St Helens SIA Aircraft Hanger Scappoose, OR AUTOMATIC FIRE SPRINKLER SYSTEM REVISION 2 MARCH 12, 2018 Scope: Furnish and install foam and water fire protection system including underground entrance
More informationMLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN
DIVISION 21 - FIRE SUPPRESSION (REFER TO SECTION 23 05 00 FOR BASIC FIRE SUPPRESSION REQUIREMENTS) 21 05 00 Common Work Results for Fire Suppression 21 13 13 Wet-Pipe Sprinkler Systems END OF SECTION FIRE
More informationCITY OF PASADENA FIRE DEPARTMENT
Page 1 of 8 CITY OF PASADENA FIRE DEPARTMENT INSTALLATION OF COMMERCIAL SPRINKLERS (Revised 12/10/2014) SCOPE: This standard applies to the design and installation of automatic fire sprinkler systems in
More informationNFPA Edition Update
NFPA 13 2013 Edition Update Session Agenda A2012 Code Cycle NFPA 13 Code Development Changes to NFPA 13 (NFPA 24) What Didn t Happen Next Steps 2 A2012 Code Cycle 800+ Proposal 500+ Comments TCC Meeting
More informationAUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)
AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations) This standard applies to the design and installation of automatic fire sprinkler systems in conjunction with
More informationB. Section Identification for Fire Suppression Piping and Equipment.
SECTION 211300 - FIRE SUPPRESSION SPRINKLERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department connections. 1.2 RELATED
More informationDIVISION 21 - FIRE SUPPRESSION
DIVISION 21 - FIRE SUPPRESSION DESIGN CRITERIA It is the policy of UC Davis to install fire sprinkler systems in all new construction/facilities. If the building is classified as a pole barn, shed, carport,
More information1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.
FIRE PROTECTION GENERAL INFORMATION 1.1 Refer to Section 230000 for General Mechanical Requirements. 1.2 Refer to Section 230529 for Hangers and Supports. 1.3 Refer to Section 230553 for Pipe and Equipment
More informationSECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE
SECTION 21 1313 WET-PIPE SPRINKLER SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Wet-pipe sprinkler system. B. System design, installation, and certification. C. Fire department connections. 1.02 RELATED
More informationUniversity of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL
SECTION 21 13 16 DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
More informationSECTION WET-PIPE SPRINKLER SYSTEMS
SECTION 21 13 13 WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationMontgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040
Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040 SPRINKLER SHOP DRAWINGS 2007 NFPA 13 and 2007 NFPA 24 Project: Listed items require sprinkler
More informationB. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.
(816) 373-4878 U1208-01/FAI29-029 (573) 751-2624 SECTION 2 105 17 - SLEEVES AND SLEEVE SEALS FOR FIRE-SUPPRESSION PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the
More informationReview of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings
Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings Reprinted with permission from NFPA 13D Installation of Sprinkler Systems in One- and two-family Dwellings and Manufactured
More informationMcMAHON FP200 OUTAGAMIE COUNTY ADMINISTRATION CENTER S. WALNUT & W. 8TH, APPLETON, WI ALTERATION / ADDITION
4/5/017 1:58:50 PM C. 1445 DRIVE NEENAH, WI 54956 EXISTING JUSTICE CENTER IS FULLY SPRINKLED C. EXISTING FIRE PUMP BASEMENT LEVEL EXISTING FDC FOR DRY STANDPIPE IN STAIRWELL SHALL BE DEMOLISHED, SEE FP
More informationDesign & Construction Standards, Revised January
PART 1 GENERAL 1.01 Scope of Standard A. This standard provides general requirements of The University of Texas at Austin for the design and construction of standpipe systems to include combination standpipe
More informationD. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:
PART 1 GENERAL 1.01 Scope of Standard A. This standard provides general requirements of Sam Houston State University for the design and construction of standpipe systems to include combination standpipe
More information1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:
SECTION 21 10 00 - WATER-BASED FIRE-SUPPRESSION PART I - GENERAL 1.1 SUMMARY A. Inclusion of sprinkler and standpipe systems shall be as determined by NFPA National Fire Code pamphlet 101 and program statement.
More informationRevision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.
SECTION 211300 FIRE SUPPRESSION SYSTEMS 1.0 All new and renovated buildings shall be provided with automatic sprinklers throughout and fire standpipe systems. The design and installation of these systems
More informationSPRINKLERS TABLE OF CONTENTS
SPRINKLERS TABLE OF CONTENTS SECTION 21 13 13 WET PIPE SPRINKLER SYSTEMS SECTION 211313 - WET PIPE SPRINKLER SYSTEMS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract,
More informationTHE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION
SECTION 21 1301- FIRE-SUPPRESSION SYSTEMS PART 1 - GENERAL 1.1 SUMMARY: A. This Section includes fire-suppression piping and equipment for the following building systems: 1. Wet-pipe, fire-suppression
More informationSECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE
SECTION 21 1316 DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE PART 1 GENERAL 1.01 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department
More informationDESIGN & CONSTRUCTION GUIDELINES
ADMINISTRATIVE SERVICES 4202 E. FOWLER AVENUE, FPC110 PHONE: (813) 974-2625 FACILITIES PLANNING & CONSTRUCTION TAMPA, FLORIDA 33620-7550 WEBSITE: USF.EDU/FPC DESIGN & CONSTRUCTION GUIDELINES DIVISION 21
More informationSECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE
SECTION 21 1316 DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE PART 1 GENERAL 1.01 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department
More informationDivision 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21
Division 21: FIRE SUPRESSION 21 1313 WET-PIPE SPRINKLER PROTECTION SYSTEM Table of Contents 1 Division 21 SECTION 21 1313 WET-PIPE SPRINKLER PROTECTION SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A.
More informationSECTION WET-PIPE SPRINKLER SYSTEMS
SECTION 21 13 13 PART 1 - GENERAL 1.1 SCOPE OF WORK A. Design, installation and testing shall be in accordance with NFPA 13 except for specified exceptions. B. The design and installation of a hydraulically
More informationUNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1
GENERAL: 1. All fire protection systems shall be installed in accordance with the International Fire Code and applicable NFPA standards. This guideline provides additional requirements for the design and
More informationB. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.
SECTION 21 13 13 FIRE PROTECTION SPRINKLER SYSTEMS PART 1 - GENERAL 1.01 SUMMARY A. Section includes labor and materials for the installation of a hydraulically calculated automatic, wet-pipe sprinkler
More informationEL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD
EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD Installation of Residential Fire Sprinkler Systems STANDARD #C-002 EFFECTIVE 03-19-2009 PURPOSE: To ensure that sprinkler plans submitted for review contain
More informationContren Learning Series Apprenticeship Training Program for Fire Sprinkler Fitters
Contren Learning Series Apprenticeship Training Program for Fire Sprinkler Fitters (Published jointly by American Fire Sprinkler Association and the National Center for Construction Education and Research.)
More informationSECTION WET FIRE SPRINKLER SYSTEMS
SUNY GENESEO 211310-1 PART 1 - GENERAL 1.1 WORK INCLUDED A. Provide labor, materials, equipment and services to perform operations required for the complete installation and related Work as required in
More informationSECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM
SECTION 213100 WET PIPE FIRE PROTECTION SPRINKLER SYSTEM PART 1 - GENERAL 1.01 GENERAL REQUIREMENTS A. The requirements of the General Conditions and Supplementary Conditions apply to all work herein.
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 21 1314W - AUTOMATIC SPRINKLER SYSTEMS (WET PIPE SYSTEMS) PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationA. Section includes wet-pipe sprinkler system, system design, installation, and certification.
SECTION 21 13 13 WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes wet-pipe sprinkler system, system design, installation, and certification. 1.2 REFERENCES A. General: Comply
More informationSECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS
SECTION 15501 WET AUTOMATIC FIRE SPRINKLER SYSTEMS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Wet automatic fire sprinkler systems including fire pump, fire pump controller, alarms, safety devices,
More informationRESIDENTIAL FIRE SPRINKLER SYSTEMS POLICY
RESIDENTIAL FIRE SPRINKLER SYSTEMS POLICY Plan Submittal and Inspection Requirements Revised 01/18/18 All residential fire sprinkler systems within the jurisdiction of the Fire Department shall meet all
More informationModel vkfd28b braided flexible sprinkler drops (lpcb approved)
Page 1 of 6 1. DESCRIPTION Viking Flexible Sprinkler Drops are a complete assembly intended for installation into commercial suspended ceilings with medium to heavy support tee bars as described in ASTM
More informationTECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608
Page 1 of 6 TECHNICAL DATA 1. DESCRIPTION The Viking Standard/Quick Response Extended Coverage Light Hazard Extra- Large Orifice (ECLH-ELO/QRECLH-ELO) Pendent Sprinkler VK608 is a thermosensitive spray
More informationFIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT
SANTA MONICA FIRE DEPARTMENT Fire Prevention Division 333 Olympic Drive 2 nd Floor Santa Monica, CA 90401 310-458-8915 / Fax 310-395-3395 FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT
More informationSprinkler Permit Applications
REQUIREMENTS FOR NFPA 13 SYSTEM Building Inspections Sprinkler Permit Applications A complete application for a Sprinkler Permit will comply with the requirements of Chapter 8 of NFPA 13. Hydraulic calculations
More informationMINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry
MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Fire Alarm Systems Plan Review Checklist Date: Permit Number: Business Name: Address: Fire Alarm System Submittal
More informationstandard/quick response extended coverage light and ordinary hazard elo sprinklers
January 27, 2012 Sprinkler 83a 1. DESCRIPTION Viking EC/QREC Light and Ordinary Hazard Extra-Large Orifice Sprinklers VK532 and VK534 are thermosensitive spray sprinklers available in several different
More informationUNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:
SECTION 211313 - WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSTANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA
Page of 5. DESCRIPTION Viking EC/QREC Ordinary Hazard ELO Fusible Element Sprinkler VK535 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS Address: Permit #: Inspector: Date Inspected: Status: Inspector: Date Inspected: Status: A-Approved;
More informationec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)
Sprinkler 83h 1. DESCRIPTION Viking Standard/Quick Response Extended Coverage Ordinary Hazard (ECOH) Upright Sprinkler VK570 and Pendent Sprinkler VK572 are thermosensitive glass bulb spray sprinklers
More informationOxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)
Oxnard Fire Department 360 W. Second Street Oxnard, CA 93030 (805) 385-7722 Fax (805) 385-8009 FIVE YEAR CERTIFICATION REPORT Service and maintenance report for automatic fire extinguishing systems, including
More informationRAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems General Description The TYCO RAPID RESPONSE Series
More informationPLAN REVIEW CHECKLIST
PLAN REVIEW CHECKLIST Date Documents Submitted: Log No.: File No.: Property Information Building Name: Building Address: Owner s Name: Owner s Address: Owner s Phone: Fax: E-mail: System Designer/Contractor
More informationSECTION (13900) - FIRE SUPPRESSION SYSTEMS
PART 1 GENERAL 1.01 SUMMARY SECTION 21 10 00 (13900) - FIRE SUPPRESSION SYSTEMS A. Section Includes: 1. Pipe and Fittings. 2. Sprinklers. B. Related Documents: 1. Marriott s Fire Protection and Life Safety
More informationculus Listed: Category VNIV Refer to the Approval Chart on page 3. VK697 Attic Upright Sprinkler Specifications:
Page 1 of 8 1. DESCRIPTION The Viking Attic Upright VK697 is a specific application attic sprinkler that provides superior fire protection in combustible and non-combustible sloped attic spaces when used
More informationA. This section includes design and performance information for fire protection and suppression systems.
SECTION 21 00 10: FIRE PROTECTION SYSTEM DESIGN 1. SUMMARY A. This section includes design and performance information for fire protection and suppression systems. 2. GENERAL A. All fire protection materials
More informationEC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION Viking Standard/Quick Response Extended Coverage Ordinary Hazard (ECOH) Pendent Sprinkler VK572 is a thermosensitive glass bulb spray sprinkler with a 14.0 (202 metric*) nominal
More informationSECTION FIRE-SUPPRESSION STANDPIPES
PART 1 - GENERAL 1.1 DESCRIPTION Fire-suppression wet and manual dry standpipes. 1.2 SCOPE OF WORK SECTION 21 12 00 A. Design, installation and testing shall be in accordance with NFPA 14 except for specified
More informationDIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES
DIVISION 21 FIRE SUPPRESSION PART 1 GENERAL 1.01 DESCRIPTION A. Provide UL listed, FM approved listed fire protection specialties or accessories as required by either the equipment manufacturer or the
More informationB. Related Sections: The following Sections contain requirements that relate to this Section.
SECTION 211313- FIRE-SUPPRESSION PIPING PART1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general prov1s1ons of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationState Board of Examiners of Plumbing, Heating & Fire Sprinkler Contractors. Residential Fire Sprinkler Inspections
State Board of Examiners of Plumbing, Heating & Fire Sprinkler Contractors Residential Fire Sprinkler Inspections Marble Mountain Demonstration https://www.youtube.com/watch?v=umzln-j_gig Facts On Fire
More information2009 International Residential Code Draft of New Fire Sprinkler Related Requirements
1. IRC Sections R313 and R314, insert two new sections as follows: R313 FIRE SPRINKLER SYSTEM FOR TOWNHOUSES R313.1 Required Installation. An automatic residential fire sprinkler system shall be installed
More informationDIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION
DIVISION 21 FIRE SUPPRESSION 21 00 00 FIRE SUPRESSION 21 01 00 Operation and Maintenance of Fire Suppression 21 01 10 Operation and Maintenance of Water Based Fire Suppression Systems 21 01 20 Operation
More informationSECTION FIRE SUPPRESSION SYSTEMS
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section. 1.2
More informationDIVISION 21: FIRE SUPPRESSION WATER BASED FIRE SUPRESSION SYSTEMS
DIVISION 21: FIRE SUPPRESSION 21 1000 WATER BASED FIRE SUPRESSION SYSTEMS 21 1200 FIRE-SUPPRESSION DRY STANDPIPES 21 1313 WET PIPE SPRINKLER PROTECTION SYSTEM 21 1314 WET-PIPE AUTOMATIC SPRINKLER SYSTEM
More informationSUMMARY. Building receiving sprinkler credit: SPRINKLERED. Grade: 68. Percent of Building Sprinklered: 100% Sprinkler Demand Met: 91%
210 N CHURCH ST CHARLOTTE NC 28202-2256 MECKLENBURG COUNTY RISK ID: 32 NC99 040235 ON-SITE SURVEY: 4/1/2009 LAST UPDATE: 4/1/2009 SUMMARY Building receiving sprinkler credit: SPRINKLERED Grade: 68 Percent
More informationSENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description
Page:1 of 5 SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description The Model ZN-RES Residential Flush Pendent
More informationATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 TECHNICAL DATA
Page 1 of 7 1. DESCRIPTION The Viking Attic Upright VK696 is a specific application concealed space sprinkler that provides superior fire protection in combustible and non-combustible sloped attic spaces
More informationModel MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)
Model MBEC-14 (SIN R6932) Features 1. Designed to be installed on piping that is supported by the primary structure, not the purlins. 2. Provides Extended Coverage Ordinary & Extra Hazard protection to
More informationstandard response dry horizontal sidewall sprinklers
February 24, 2012 Sprinkler 102a 1. DESCRIPTION Viking Standard Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers
More informationEL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD
EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD INSTALLATION OF COMMERCIAL FIRE SPRINKLER SYSTEMS STANDARD #C-001 EFFECTIVE 03-25-2009 PURPOSE: To ensure that sprinkler plans submitted for review contain
More informationSTANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA
Page 1 of 5 1. DESCRIPTION Viking EC/QREC Ordinary Hazard ELO Fusible Element Pendent Sprinkler VK537 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings
More informationRESIDENTIAL MULTI-USE FIRE SPRINKLER SYSTEMS PERMIT SUBMITTAL REQUIREMENTS
History: RESIDENTIAL MULTI-USE FIRE SPRINKLER SYSTEMS PERMIT SUBMITTAL REQUIREMENTS Per the City adopted 2009 IRC, section R313, automatic fire sprinkler systems are required for all one and two family
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 21 1314D - AUTOMATIC SPRINKLER SYSTEMS (DRY-PIPE) PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationSTANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION Viking EC/QREC Pendent Sprinkler VK602 is a small thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying design requirements.
More informationCLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau
CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 Permit Type: 105.7.13 Control Number: A.0 Effective Date: 11/15/11 TITLE:
More informationAUTOMATIC FIRE SPRINKLER SYSTEMS
MCKINNEY FIRE DEPARTMENT FIRE MARSHAL S OFFICE AUTOMATIC FIRE SPRINKLER SYSTEMS These guidelines are to be followed when a business, facility or organization installs an automatic fire sprinkler system
More informationRefer to the specific sprinkler or spray nozzle technical data pages for sprinkler listings and approvals.
Page 1 of 5 1. DESCRIPTION A. Sprinkler Cabinets Viking sprinkler cabinets are metal enclosures constructed to store an emergency supply of spare sprinklers and a sprinkler installation wrench. NFPA 13
More informationThe Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure
Sprinkler 41t 1. DESCRIPTION Viking Quick Response Upright and Pendent Sprinklers are small thermosensitive glass bulb spray available with various finishes and temperature ratings to meet design requirements.
More informationResidential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)
Page:1 of 5 Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design) General Description The Model HF-RES Residential Flush Horizontal Side-Wall
More informationSpecialties Quality, Durability, Reliability. FIrE ProTECTIon
_specialties:pcsectiond_new 2/6/2012 4:46 PM Page -36 36 SECTIon Specialties Quality, Durability, Reliability FIrE ProTECTIon In addition to our plumbing business, LYNCAR has been a leading supplier to
More informationWET AUTOMATIC FIRE SPRINKLER SYSTEMS
SECTION 15501 WET AUTOMATIC FIRE SPRINKLER SYSTEMS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Wet automatic fire sprinkler systems including fire pump, fire pump controller, alarms, safety devices,
More informationqr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013
March 14, 2013 Sprinkler 42h 1. DESCRIPTION Viking Quick Response Fusible Element Upright and Pendent Sprinklers are small thermosensitive solder link spray sprinklers available with various finishes and
More informationSTANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION Viking Standard/QREC Light Hazard ELO Fusible Element Pendent Sprinkler VK617 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings
More informationmicrofast sr/qr extended coverage pendent sprinkler
Page 1 of 6 1. DESCRIPTION Viking Microfast EC/QREC Pendent Sprinkler VK600 is a small thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying design
More information