1 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 17065:2012 to provide product conformity certification Unit Abenbury Way Wrexham Industrial Estate Wrexham LL13 9UZ United Kingdom Contact: Sean Clarke Tel: Fax: Website: Locations where certification activities covered by the above Accreditation are undertaken Unit Abenbury Way Wrexham Industrial Estate Wrexham LL13 9UZ United Kingdom Flexible Scope The laboratory is accredited to ISO/IEC 17065:2012 for product certification activities in accordance with the standards included on this schedule. This may also include certifications on the same or similar product types against standards, or customer-specified methods, that are not specifically listed in this Schedule, providing that: (1) The method or standard does not introduce new principles of testing / measurement. (2) The method or standard does not require testing / measurements to be made outside the parametric boundaries defined within the standard specifications already accredited and detailed within this Schedule of Accreditation. Information about flexible scopes of accreditation is available on the UKAS website. Assessment Manager: RC3 Page 1 of 7

2 DETAIL OF ACCREDITATION Explosion prevention and protection Basic concepts and methodology EN :2011 EN :2007 (withdrawn) Explosion prevention and protection Basic concepts and methodology for mining EN :2014 EN :2002 (withdrawn) Group II engines for flammable gas and vapour atmospheres EN :2000 Group I engines for workings susceptible to firedamp and/or combustible dust EN :2000 Group II engines for flammable dust atmospheres EN :2000 Automatic nozzles for fuel dispensers EN 13012:2012 EN 13012:2001 (withdrawn) Non-electrical equipment for potentially explosive atmospheres: EN :2009 General Requirements Protection by flow restricting enclosures fr EN :2004 Degrees of protection provided by enclosures (IP code) EN 60529: A1: A2:2013 EN 60529: A1:2000 (withdrawn) Protection by flameproof enclosure d EN :2005 Non Electrical Equipment - Constructional Safety c EN :2011 EN :2003 (withdrawn) Protection by control of ignition source b EN :2005 Assessment Manager: RC3 Page 2 of 7

3 Non Electrical Equipment - Liquid Immersion k EN :2003 Non-electrical equipment for use in explosive atmospheres Basic methods and requirements ISO/IEC :2016 Non-electrical equipment for use in explosive atmospheres - Non-electrical type of protection constructional safety 'c', control of ignition sources 'b', liquid immersion 'k' ISO/IEC :2016 Metering pumps, dispensers and remote pumping units EN :2012 EN :2004+A1:2009 (withdrawn) Safe breaks for use on metering pumps and dispensers EN :2012 EN :2004 (withdrawn) Shear valves EN :2012 EN :2004 (withdrawn) Swivels for use on metering pumps and dispensers EN :2012 EN :2004 (withdrawn) LPG filling systems for light and heavy duty vehicles, nozzle, test requirements and dimensions EN 13760:2003 LPG equipment for automotive filling stations. Dispensers EN :2013 EN :2006+A1:2009 (withdrawn) Protection of fans working in potentially explosive atmospheres EN 14986:2007 Petrol filling stations safety requirements for the construction of submersible pump assemblies EN 15268:2008 Flame arrestors EN ISO 16852:2010 Assessment Manager: RC3 Page 3 of 7

4 Electrostatic hand-held spraying equipment EN 50050:2006 Group 1 Category M1 Equipment EN 50303:2000 Pressurised rooms IEC :2010 EN 50381:2004 EN 50381:2004/AC:2005 Requirements for electrical/electronic/programmable electronic safety-related systems BS EN 50495:2010 Electrical apparatus for potentially explosive atmospheres using the following protection concepts: General requirements EN :2012+A11:2013 IEC :2011 EN :2009 (withdrawn) IEC :2007 (withdrawn) Flameproof enclosures d EN :2014 IEC :2014 EN :2007 (withdrawn) EN :2003 (withdrawn) IEC :2007 (withdrawn) IEC :2003 (withdrawn) Pressurised apparatus p EN :2014 IEC :2014 EN :2007 (withdrawn) IEC :2007 (withdrawn) Powder filling q EN :2015 IEC :2015 EN :2007 (withdrawn) IEC :2007 (withdrawn) Oil immersion o EN :2015 IEC :2015 EN :2007 (withdrawn) IEC :2007 (withdrawn) Assessment Manager: RC3 Page 4 of 7

5 Increased safety e EN :2015 IEC :2015 EN :2007 (withdrawn) IEC :2006 (withdrawn) Intrinsic safety I EN :2012 IEC :2011 Type of protection n EN :2010 IEC :2010 Encapsulation m EN :2015 IEC :2015 EN :2009 (withdrawn) IEC :2009 (withdrawn) Intrinsically safe electrical systems EN :2010 IEC :2010 Equipment Group II Category IG/Zone 0 EN :2007 IEC :2006 Electrical apparatus for explosive gas atmospheres. Fieldbus intrinsically safe concept (FISCO) and fieldbus non-incendive concept (FNICO) IEC :2008 Protection of equipment and transmission systems using Optical Radiation EN :2015 IEC :2015 EN :2007 (withdrawn) IEC :2006 (withdrawn) Electrical resistance trace heating EN :2007 IEC :2007 Protection by enclosure t EN :2014 IEC :2013 EN :2009 (withdrawn) IEC :2008 (withdrawn) Assessment Manager: RC3 Page 5 of 7

6 Electrostatics hazards Tests EN :2015 IEC :2015 Special protection (Ex s) PD CLC/TR :2015 EN :2012 (withdrawn) IEC :2012 (withdrawn) Caplights for use in mines susceptible to firedamp EN :2011 IEC :2011 Electrical apparatus for use in the presence of combustible dust: Type of protection 'pd' EN :2006 IEC :2001 Electrical resistance trace heating systems for industrial and commercial applications EN :2013 EN :2006 (withdrawn) IEEE 515:2011 Cable glands for electrical installations EN 62444:2013 IEC 62444:2010 Explosive atmospheres. Electrical installations inspection and maintenance EN : 2014 IEC : 2013 Explosive atmospheres. Electrical installations design, selection and erection EN :2014 IEC :2013 Potentially explosive atmospheres. Application of quality systems. EN ISO/IEC :2011 ISO/IEC :2011 END Assessment Manager: RC3 Page 6 of 7

7 Accreditation for the purpose of Notified Body Activity taking into account EA2/17 and relevant requirements of ISO 17021:2011 Directive / Regulation Conformity Assessment procedure/ Module/article Category of products or individual products Essential requirements: specification / Properties/s Equipment Intended for use in Potentially Explosive Atmospheres (ATEX) 94/9/EC (As Amended) Implemented in UK law by: Annex III / Schedule 6 EC-Type examination Annex IV /Schedule 7 ion QA Annex V / Schedule 8 verification Equipment in :- Equipment group I, categories M1 and M2. Equipment group II, categories 1, 2 and 3. Essential Health and Safety Requirements, Annex II of the Directive and Schedule 3 of the Regulations The Equipment and Protective Systems Intended for use in Potentially Explosive Atmospheres Regulations 1996, No 192 (As Amended Annex VI / Schedule 9 Conformity to type Annex VII / Schedule 10 QA Annex IX / Schedule 12 Unit verification Storage of Technical files Acknowledgment of receipt and retention of technical files Acknowledgment of receipt and retention of technical files Equipment and protective systems intended for use in potentially explosive atmospheres (ATEX) 2014/34/EU (As amended) Annex V verification Annex III EC type-examination END Assessment Manager: RC3 Page 7 of 7

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 17065:2012 to provide product conformity certification Newport Business Park New Port Road Ellesmere Port CH65 4LZ United Kingdom Contact:

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK SIRA Certification Service Accredited to ISO/IEC 17065:2012 to provide product conformity Unit 6 Hawarden Industrial Park Hawarden Deeside

More information

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US. Flexible Schedule of Accreditation SIRA CERTIFICATION SERVICE. Issue No: 072A Issue date 23 rd March 2018 Unit 6 Hawarden Industrial Park Hawarden, CH5 3US, United Kingdom Contact: Mr A Myler Tel: +44

More information

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US. Flexible Schedule of Accreditation SIRA CERTIFICATION SERVICE. Issue No: 63A Issue date 16 th June 2015 Unit 6 Hawarden Industrial Park Hawarden, CH5 3US, United Kingdom Contact: Mr A Myler Tel: +44 (0)1244

More information

Official Journal of the European Union

Official Journal of the European Union C 20/16 27.1.2009 Commission communication in the framework of the implementation of the Directive 94/9/EC of the European Parliament and the Council on the approximation of the laws of the Member States

More information

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION 8.4.2016 EN Official Journal of the European Union C 126/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework

More information

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 335/02)

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 335/02) C 335/10 EN Official Journal of the European Union 9.10.2015 Commission communication in the framework of the implementation of Directive 94/9/EC of the European Parliament and of the Council of 23 March

More information

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2016/C 126/02)

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2016/C 126/02) 8.4.2016 EN Official Journal of the European Union C 126/13 Commission communication in the framework of the implementation of Directive 2014/34/EU of the European Parliament and of the Council on the

More information

C 319/6 Official Journal of the European Union

C 319/6 Official Journal of the European Union C 319/6 Official Journal of the European Union 5.11.2013 Commission communication in the framework of the implementation of the Directive 94/9/EC of the European Parliament and the Council of 23 March

More information

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION 8.9.2017 EN Official Journal of the European Union C 298/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework

More information

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2018/C 092/02)

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2018/C 092/02) 9.3.2018 EN Official Journal of the European Union C 92/87 Commission communication in the framework of the implementation of Directive 2014/34/EU of the European Parliament and of the Council on the harmonisation

More information

Official Journal of the European Union

Official Journal of the European Union 9.3.2006 C 57/17 Commission communication in the framework of the implementation of Directive 94/9/EC of the European Parliament and of the Council of 23 March 1994 on the approximation of the laws of

More information

Do you manufacture equipment or protective systems for use in potentially explosive atmospheres? Do you process, trade or import them?

Do you manufacture equipment or protective systems for use in potentially explosive atmospheres? Do you process, trade or import them? TÜV NORD CERT GmbH Geschäftsstelle Hannover Am TÜV 1 30519 Hannover Zertifizierung Certification body for equipment according to Directive 94/9/EC of TÜV NORD CERT GmbH Summarized Information Directive

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, hertsey Lane, Staines-upon-Thames, TW18 3HR, UK SA Group Testing UK Ltd ISO/IE 17025:2005 Unit 6 Hawarden Industrial Park Hawarden Deeside H5 3US ontact: Mr S P ork Tel: +44 (0)1244 670900

More information

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC Quick Introduction to TÛV Denmark TÜV Denmark - is a part of the TÜV NORD Group a global Organisation f Certification and Inspection of: Quality Management Systems, Products, Processes and Qualification

More information

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES. ET 105:2001 (Second Edition)

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES. ET 105:2001 (Second Edition) NATIONAL RULES FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES ET 105:2001 (Second Edition) Consolidated Amendments, Corrigenda and Errata 01/2010 Introduction When ET 105:2001 was originally

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Presley House Presley Way Crownhill Milton Keynes MK8 0ES United Kingdom Contact: Jeremy Hodge Tel: +44 (0) 1908 267300 Fax: +44 (0) 1908

More information

HARMONISATION STATUS OF SELECTED ELECTRICAL AND NON-ELECTRICAL Ex STANDARDS MARCH 2018

HARMONISATION STATUS OF SELECTED ELECTRICAL AND NON-ELECTRICAL Ex STANDARDS MARCH 2018 Harmonisation status of selected electrical and non-electrical ex standards BAS-PS-010 - Issue 1 - March 2018 P. 1 HARMONISATION STATUS OF SELECTED ELECTRICAL AND NON-ELECTRICAL Ex STANDARDS MARCH 2018

More information

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining The Laboratory is qualified to update standards identifying the test procedures. The laboratory requires/applies a flexible scope of accreditation permitted as detailed in the Annex. Updated list of activities

More information

IEC SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR USE IN EXPLOSIVE ATMOSPHERES (IECEx SCHEME) INTRODUCTION

IEC SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR USE IN EXPLOSIVE ATMOSPHERES (IECEx SCHEME) INTRODUCTION IEC SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR USE IN EXPLOSIVE ATMOSPHERES (IECEx SCHEME) Ex Management Committee, ExMC TITLE: IECEx Assessment Report for an extension of scope for

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ISO/IEC 17065:2012 to provide product conformity 20 Park Street Princes Risborough Buckinghamshire HP27 9AH Contact: Ian Woodhouse Tel: +44

More information

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE DANISH TECHNOLOGICAL INSTITUTE The Danish Technological Institute is a self-owned and not-f-profit institution. We develop, apply and disseminate research- and technologically-based knowledge f the Danish

More information

GUIDELINES. the Interpretation of

GUIDELINES. the Interpretation of GUIDELINES on the Interpretation of ATEX Directive Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Directive 94/9/EC for the Valve and Actuator Industry prepared

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Lee House 90 Great Bridgewater Street Manchester M1 5JW Contact: Helen Taft Tel: +44 (0) 161 237 4080 E-Mail: helen.taft@centreforassessment.co.uk

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 60079.0:2012 IEC 60079-0, Ed. 6.0 (2011) AS/NZS 60079.0:2012 Australian/New Zealand Standard Explosive atmospheres Part 0: Equipment General requirements AS/NZS 60079.0:2012 This Joint Australian/New

More information

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres Quick Introduction to: DANISH TECHNOLOGICAL INSTITUTE The Danish Technological Institute is a self-owned and not-fprofit institution. We develop, apply and disseminate research- and technologically-based

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Chatsworth Technology Park Dunston Road Chesterfield Derbyshire S41 8XA Contact: Mr M Watson Tel: +44 (0)1246 263861 Fax: +44 (0)1246 260919

More information

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas

More information

EXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009

EXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009 EXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009 Number ExNB/CS/ DS (1) Edition Subject / Keywords 98/06/001 1.0 Certification of a torch according to EN

More information

Fact Sheet No.4. CompEx Modules EX01R to EX04R for Gas and Vapour Environments

Fact Sheet No.4. CompEx Modules EX01R to EX04R for Gas and Vapour Environments Fact Sheet No.4 CompEx Modules EX01R to EX04R for Gas and Vapour Environments Module Breakdown EX01R: EX02R: EX03R: EX04R: The preparation & installation of Ex d, n, e and p equipment in potentially explosive

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Accredited to ISO/IEC 17065:2012 to provide product conformity certification Wonersh House The Guildway Old Portsmouth Road Guildford Surrey

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Issue No: 035 Issue date: 23 February 2017 16 Abbotsinch Road Grangemouth FK3 9UX Contact: Mr G Falconer Tel: +44 (0)1324 489182 Fax: +44

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 118 Lupton Avenue Leeds LS9 6ED Contact: Mr Scott Wiseman Tel: +44 (0)113 248 8830 Fax: +44 (0)113 248 0239 E-Mail: scott@hstts.co.uk Website:

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60079-0 Edition 3.1 2000-06 Edition 3:1998 consolidated with amendment 1:2000 Electrical apparatus for explosive gas atmospheres Part 0: General requirements IEC 2000 Copyright

More information

INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME)

INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME) INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME) To: Members of the Management Committee ExMC Introductory

More information

Fact Sheet No.2. CompEx Modules EX01 to EX04 for Gas and Vapour Environments

Fact Sheet No.2. CompEx Modules EX01 to EX04 for Gas and Vapour Environments Fact Sheet No.2 CompEx Modules EX01 to EX04 for Gas and Vapour Environments Module Breakdown EX01: The preparation & installation of Ex d, n, e and p equipment in potentially explosive atmospheres. EX02:

More information

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection Skip to main content Skip to primary navigation Home Home About this portal Latest updates Menu Print Save Email Resource detail Citations AS/NZS 60079.14:2009 Explosive atmospheres - Part 14: Electrical

More information

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS The ATEX Directive consists of two EU Directives, ATEX Directive 2014/34/EU and ATEX Directive 99/92/EC. ATEX Directive 2014/34/EU embodies the European minimum

More information

EMIRATES CONFORMITY ASSESSMENT SCHEME (ECAS): ECASEx COMPLIANCE

EMIRATES CONFORMITY ASSESSMENT SCHEME (ECAS): ECASEx COMPLIANCE APPLICANTS AND MANUFACTURERS GUIDANCE EMIRATES CONFORMITY ASSESSMENT SCHEME (ECAS): COMPLIANCE intertek.com/ecas CONTENTS Executive Summary 3 Program Scope 4 Manufacturers Responsibilities 6 Application

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Building 63 Haslar Marine Technology Park Haslar Road Gosport Hampshire PO12 2AG Contact: Mr S Kumar Tel: +44 (0) 208 692 5050 Fax: +44 (0)

More information

Training, Assessment, Consultants for Hazardous & Industrial Areas

Training, Assessment, Consultants for Hazardous & Industrial Areas Training, Assessment, Consultants for Hazardous & Industrial Areas EPIT provides specialist training, assessment and consultancy services for engineers working in hazardous and industrial environments.

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 4ward Ltd 5 Hampers Common Industrial Estate Petworth West Sussex GU28 9NR Contact: Ms Lesley Komatsu Tel: +44 (0)1798-342240 Fax: +44 (0)1798-344482

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Exova (UK) Limited trading as Warrington Certification Issue No: 033 Issue date: 06 November 2017 to provide product conformity Holmesfield

More information

Report on the activities of the ATEX consultant. Xavier Lefebvre. Contract : CENELEC/NA Consultant/2013-1

Report on the activities of the ATEX consultant. Xavier Lefebvre. Contract : CENELEC/NA Consultant/2013-1 Report on the activities of the ATEX consultant Xavier Lefebvre Contract : CENELEC/NA Consultant/2013-1 Period covered: from 1 January 2013 to 1 July 2013 1. Attended meetings Date Subject Location 2013.01.28

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Accredited to ISO17065:2012 to provide product conformity Octagon House Concorde Way Segensworth North Fareham Hampshire PO15 5RL Contact: Mr Mark Jenkins Tel: +44 (0) 1489 558258 Fax: +44 (0)1489 558101

More information

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The entrepreneurial basis of the R. STAHL Technology Group follows a long tradition. The product range is aimed at specialised

More information

Approval of Ex (Electrical) Equipment for use/installation in Hazardous Areas.

Approval of Ex (Electrical) Equipment for use/installation in Hazardous Areas. Approval of Ex (Electrical) Equipment for use/installation in Hazardous Areas. Requirement under Rule 102 of the Petroleum Rules, 2002 lays down that no electrical wiring shall be installed and no electrical

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Maxwell Road Stevenage Hertfordshire SG1 2EW Contact: Darren Hone Tel: +44 (0)1438 777700 Fax: +44 (0)1438 777800 E-Mail: info@fira.co.uk

More information

Certificate Surveillance audit

Certificate Surveillance audit Certificate Surveillance audit The quality management System of the Company Manufacturer: R. STAHL Schaltgeräte GmbH Address: Am Bahnhof 30, 74638 Waldenburg, Germany 7 Site(s) of manufacture: R. STAHL

More information

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further. ATEX SOLUTIONS In order to apply a single level for health and safety requirements and to overcome barriers of trade within Europe, national regulations for explosion prevention were harmonized in 1975

More information

EQUIPMENT INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

EQUIPMENT INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) English European Commission > Enterprise & Industry > Industry Sectors > Equipment intended for use in Potentially Explosive Atmospheres (ATEX) > How to apply the Directive > Contact Search Considerations

More information

HazLoc Essential Guides:

HazLoc Essential Guides: HazLoc Essential Guides: Intertek Deeside Lane, Chester, CH1 6DD UK hazloc@intertek.com 01244 882590 www.intertek-hazloc.com Introduction This white paper aims to clarify ATEX Technical Files. As a Notified

More information

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt Airo Wireless Intrinsically Safe White Paper Written By: David Schmitt Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection certification for safe operation with electronic

More information

WHAT WHITE PAPER IS POTENTIALLY EXPLOSIVE ATMOSPHERE CERTIFICATION AND WHY YOU. June 2010

WHAT WHITE PAPER IS POTENTIALLY EXPLOSIVE ATMOSPHERE CERTIFICATION AND WHY YOU. June 2010 WHITE PAPER WHAT IS POTENTIALLY EXPLOSIVE ATMOSPHERE CERTIFICATION AND WHY YOU MAY NEED IT! June 2010 Copyright Extronics Ltd 2010 The information contained in this document is subject to change without

More information

TECHNICAL SOLUTIONS APPLICABLE TO ELECTRICAL EQUIPMENTS DESIGNED FOR USE IN EXPLOSIVE GAS ATMOSPHERES

TECHNICAL SOLUTIONS APPLICABLE TO ELECTRICAL EQUIPMENTS DESIGNED FOR USE IN EXPLOSIVE GAS ATMOSPHERES TECHNICAL SOLUTIONS APPLICABLE TO ELECTRICAL EQUIPMENTS DESIGNED FOR USE IN EXPLOSIVE GAS ATMOSPHERES TECHNICAL SOLUTIONS APPLICABLE TO ELECTRICAL EQUIPMENTS DESIGNED FOR USE IN EXPLOSIVE GAS ATMOSPHERES

More information

UL HAZARDOUS LOCATIONS SERVICES

UL HAZARDOUS LOCATIONS SERVICES UL HAZARDOUS LOCATIONS SERVICES The international preference in hazardous locations certification for over 100 years ul.com/hazloc Explosive Gas Atmospheres Class I Division S Includes flammable gases,

More information

SELECTION, INSTALLATION & TESTING OF ELECTRICAL EQUIPMENTS IN HAZARDOUS AREA

SELECTION, INSTALLATION & TESTING OF ELECTRICAL EQUIPMENTS IN HAZARDOUS AREA Training Title SELECTION, INSTALLATION & TESTING OF ELECTRICAL EQUIPMENTS IN HAZARDOUS AREA Training Duration 5 days Training Venue and Dates REF EE019 Selection, Installation & Testing of Electrical Equipments

More information

Guide for hazardous areas

Guide for hazardous areas Guide for hazardous areas 1 Hazardous areas definitions 2 Gas and dust s 3 Temperature classifications 4 Common flammable gases, vapours and dust types 5 Protection concepts ATEX and IECEx 6 Protection

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Accredited to ISO17065:2012 to provide product conformity Octagon House Concorde Way Segensworth North Fareham Hampshire PO15 5RL Contact: Mr Mark Jenkins Tel: +44 (0) 1489 558258 Fax: +44 (0)1489 558101

More information

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or

More information

Schedule of Accreditation Issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation Issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Issued by 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Accredited to ISO/IEC 17065:2012 to provide product conformity certification Academy Place 1-9 Brook Street Brentwood Essex CM14

More information

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing

More information

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor Report No. 3040249EC FM Approvals Ltd 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT Product: Model and/or Type Reference: Flame Detector IPES-IR3 Description of the Product:

More information

Legislation, Standards and Technology. IEC TC 41 Explosion protection of electrical equipment

Legislation, Standards and Technology. IEC TC 41 Explosion protection of electrical equipment Legislation, Standards and Technology Ex-News Information about explosion protection by Thorsten Arnhold (Editorial Board) IEC TC 41 Explosion protection of electrical equipment In October 2009 Technical

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION IEC TS 60079-46 Edition 1.0 2017-08 Explosive atmospheres Part 46: Equipment assemblies INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 29.260.20 ISBN 978-2-8322-4763-1 Warning! Make

More information

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories Hazardous Locations: Understanding the Basics of Global Compliance Requirements Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories DISCLAIMER/ TERMS OF USE: THE INFORMATION

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ISO/IEC 17065:2012 to provide product conformity certification Presley Way Crownhill Milton Keynes MK8 0ES Contact: Tracie Hunter Tel: +44 (0)1908 267300 Fax: +44 (0)1908 267255 E-Mail: mail@basec.org.uk

More information

EUROPUMP ATEX Guideline Part II

EUROPUMP ATEX Guideline Part II EUROPEAN ASSOCIATION OF PUMP MANUFACTURERS ASSOCIATION EUROPÉENNE DES CONSTRUCTEURS DE POMPES EUROPÄISCHE VEREINIGUNG DER PUMPENHERSTELLER EUROPUMP ATEX Guideline Part II Application of the EC-Guidelines

More information

MARKING EC Directive 97/23 PED (Pressure Equipment Directive)

MARKING EC Directive 97/23 PED (Pressure Equipment Directive) MARKING EC Directive 97/23 PED (Pressure Equipment Directive) Field of application The Directive applies to the design, manufacturing and conformity assessment of the pressure equipment and of their groups

More information

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations) Annex II Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations) 1. According to Recommendation L, market surveillance should be included as a flanking area of

More information

User s Manual YTA610 and YTA710 NEPSI Certification

User s Manual YTA610 and YTA710 NEPSI Certification User s Manual YTA60 and YTA70 NEPSI Certification [Option code: /NS, /NS5 and /NF] st Edition . INTRODUCTION Thank you for purchasing the YTA60 and YTA70 Temperature transmitters. This manual contains

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Certsure LLP trading as NICEIC or ELECSA ISO/IEC 17065:2012 to provide product conformity certification Warwick House Houghton Hall Park Houghton

More information

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas Page 1 of 5 Title Install fixed gas detection apparatus in hazardous areas Level 4 Credits 2 Purpose This unit standard covers the installation, calibration, and response checking of fixed gas detection

More information

Numerical Standards Listing

Numerical Standards Listing Numerical Standards Listing ISA-RP2.1-1978 - Manometer Tables ISA-5.1-1984 (R1992) - Instrumentation Symbols and Identification (Formerly ANSI/ISA-5.1-1984 [R1992]) ISA-5.2-1976 (R1992) - Binary Logic

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Accredited to ISO/IEC 17065:2012) to provide product conformity certification 4th Floor, Mill 3 Pleasley Vale Business Park Mansfield Nottinghamshire

More information

ATEX/05/1/7. In detail:

ATEX/05/1/7. In detail: ATEX/05/1/7 This paper contains available and signed ExNBG clarification sheets and is subdivided in 4 sections. Please be aware that this item will require a large part of the time available for the meeting.

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Accessories BF 12 Mounting flange, 12 mm Technical Data specifications Switching element function NAMUR, NO Rated operating distance s n 4 mm Installation non-flush

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK AMP House Suites 27-29, Fifth Floor Dingwall Road Croydon CR0 2LX Contact: Mr Paul Ward Tel: +44 (0)20 8680 7711 Fax: +44 (0)20 8680 4035

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:2 Status: Current Certificate history:

More information

HazLoc Essential Guides:

HazLoc Essential Guides: HazLoc Essential Guides: Intertek Deeside Lane, Chester, CH1 6DD UK hazloc@intertek.com +44 1244 882590 www.intertek-hazloc.com Contents Contents... 1 Introduction... 1 Introduction to Ex... 1 ATEX Overview...

More information

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC By: Helge Knudsen, Test&Approval, Niros Telecommunication A/S You may have heard those expressions concerning Transceivers and other electric equipment

More information

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3. Rev. 1 03/05/2015 ANNEX A to the Yokogawa Corporation of America Quality Assurance Manual For Additional Requirements selectively applied to ATEX and IECEx certified products CONTENTS 1. Scope 2. Purpose

More information

Information and Notices

Information and Notices Official Journal of the European Union ISSN 1725-2423 C 183 English edition Information and Notices Volume 53 7 July 2010 Notice No Contents Page IV Notices NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES,

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Stable Court Contact: Mark Richens Oakley Tel: +44 (0)1630 658568 Nr Market Drayton Fax: +44 (0)1630 658921 Shropshire E-Mail: mark@cranage.co.uk

More information

ATEX 137. What it means for motor users

ATEX 137. What it means for motor users ATEX 137 What it means for motor users ATEX puts responsibility for explosion protection firmly in the lap of the end user, who is responsible for the safe operation of all the equipment on his site. ATEX

More information

ESSENTIAL EXPLOSION PROTECTION

ESSENTIAL EXPLOSION PROTECTION ESSENTIAL EXPLOSION PROTECTION 2 3 FOREWORD In many industries, gases, vapours, mist and dust develop and escape in the course of manufacturing, processing, transporting and storing combustible substances.

More information

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,

More information

."/6"&91-04*0/ 1305&$5*0/

./6&91-04*0/ 1305&$5*0/ 130$&44 "650."5*0/."/6"&91-04*0/ 1305&$5*0/ -RXVMRWMG 7EJIX] )\TPSWMSR 4VSXIGXMSR Special notes Notes on content: This manual contains manuscripts of various presentations, each complete in and of itselves,

More information

ATEX, NOMENCLATURE AND CODING

ATEX, NOMENCLATURE AND CODING Technical Notes ATEX, NOMENCLATURE AND CODING The intent of this technical note is approach to the user to the ATEX normative. For this we will begin defining, what is an explosive atmosphere, what are

More information

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here. A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here Introduction Potentially Explosive Atmospheres exist where there is a risk

More information

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates Note: While this material was originally prepared for presentation in February 1999, it has been updated to reflect the evolving technical requirements now applicable as of April 2003. UL Topic III Converting

More information

EEHA CERTIFICATION FPSO S FOR INTERNATIONAL OPERATIONS

EEHA CERTIFICATION FPSO S FOR INTERNATIONAL OPERATIONS EEHA CERTIFICATION FPSO S FOR INTERNATIONAL OPERATIONS R.L.Narayanan IECEx CoPC, CP Eng (Austr), C Eng (UK), C Mar Eng, FSEng, Member,Energy Institute(Uk) rl.narayanan@electek.com.au www.electekexsolutions.com.au

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Wallace Way Tern Valley Business Park Market Drayton Shropshire TF9 3AG Contact: Mark Richens Tel: +44 (0) 1630 658568 E-Mail: mark@cranage.co.uk

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ISO/IEC 17021-1:2015 to provide environmental management systems certification Unit 6 Hawarden Industrial Park Hawarden Deeside CH5 3US United

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD IEC 60092-502 Fifth edition 1999-02 Electrical installations in ships Part 502: Tankers Special features Installations électriques à bord des navires Partie 502: Navires-citernes

More information

Certification Supplement Manual

Certification Supplement Manual SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 5 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EU DECLARATION OF CONFORMITY 3 EUROPEAN

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames. 2 Pine Trees, Chertsey Lane, Staines-upon-Thames. TW18 3HR Unit 8B, B W Estates Oldmixon Crescent Weston-super-Mare North Somerset BS24 9BA Contact: Mr K D James Tel: +44 (0)1934-644866 Fax: +44 (0)1934-413909

More information