1 WORLD LEADER OF INNOVATIVE SOLUTIONS IN FIRE DETECTION AND ALARM SYSTEMS Product Catalogue Australia 2015

2 Contents Fire Control Panels ZoneSense DH4 Conventional 4 ZoneSense PLUS Conventional 6 ZoneSense PLUS AR Conventional 8 LoopSense Intelligent 10 FireFinder PLUS Intelligent 12 FireFinder Intelligent 14 Add Ons 16 Alarm Systems Standalone Occupant Warning Panel 28 Occupant Warning System Add-Ons 30 EV3000 Emergency Control Panel 32 EV3000 Emergency Control Panel - Add Ons 34 Graphics Package Smart GraphicsHD 38 Detection & MCP s Conventional Series 65 Detection 40 Heat Detection 42 Manual Call Points 45 Sampling Duct Units 46 Beam Detection 47 Addressable XP95 Detection 48 Discovery Detection 50 Manual Call Points 53 Duct Sampling Unit 54 Specialist Detection Flame Detection 55 Hazardous Area Detection 58 Marine Detection 64 Xpander Wireless Detection 66 Aspirating Smoke Detection -Wagner Titanus Family 70 High Sensitivity Detection System 72 Aspirating Smoke Detection - FastSense 73 Audio Visual & Interfaces XP95 Interfaces 76 Conventional Audio Visual 80 Remote Indicators 83 Bells 84 Warning Signs 85 Addressable Audio & Visual 89 Hazardous Area - Intrinsically Safe 92 Hazardous Area- Flameproof Equipment 93 Cable 2 Core TPS Cable 94 Ancillaries Electro-Magnetic Door Holders 97 Power Supplies 101 Batteries 103 Test Equipment 103 Ancillary Equipment 105 Contact Page 107

3 4 Fire Control Panels 5 ZoneSense DH4 Conventional Specifications Power Supply Mains Supply voltage Nom. Operating voltage Power Supply Current Quiescent Current Operating Temperature Relative Humidity Zone Detection Circuit No of Zones Zone Monitoring Zone Quiescent Current No of Detectors/Circuits End Of Line (EOL) Max Cable Length Outputs Available Alarm Outputs (monitored) Door Holder outputs (monitored) Fire Output Relay (voltage free) Fault Output Relay (voltage free) Auxiliary DC Output Miscellaneous Features Class Change Input Alert Input Battery Monitoring Hz 27 VDC 1.6 A (max) 20 ma (without Door Holder) -5 to +55 C (no icing) 25% - 75% (non condensing) Four (4) x 2-wire system Open and Short circuit 4mA, 10uF EOL 40 (max) 10uF EOL 3km (Based on cable resistive and capacitive values of 50Ω and 1uF respectively) Open Collector, 250mA (2 O/P s available) 10KΩ EOL Open Collector, 250mA (2 O/P s available) 10KΩ EOL NO, C, NC Contact rating: 30VDC NO, C, NC Contact rating: 30VDC 24VDC Non-Latching, switched -ve Non-Latching, switched -ve 4 Way DIP switch array (factory set to OFF ) Mechanical Packed H 310mm x W 500mm x D 110mm Material ABS Cabinet Metal Cabinet ABS/Blend High Impact 1.2mm Mild Steel Finish ABS Light Grey Metal Oyster Matt Ripple H 300 x W 360 x D 100 H 300 x W 360 x D 100 Packed excluding batteries 3kg 5.2kg The ZoneSense DH4 Control Panel is a simple and low cost 4 zone panel. It is an ideal fire panel for any small residential applications (not requiring brigade monitoring) or can also be used as a door holder control panel. Each of the 4 zones can be connected up to 40 x high quality commercial grade conventional fire detectors to deliver a high quality detection & alarm system. It is possible to use the ZoneSense panel in Mains only option mode which eliminates the need to connect back up batteries. Both ABS and Metal versions are available. Dual Door Holder Outputs Mains Only Mode Low Quiescent Current Walk Test Facility Alert Input Up to 40 Conventional detectors per Zone Available in ABS (BX1) and Metal (BX10) cabinet versions Item Numbers ZoneSense DH4 ABS (BX1) excl Batteries ZoneSense DH4 METAL (BX10) excl Batteries Metal BX10 Surround ENC3016-A

4 6 Fire Control Panels 7 ZoneSense PLUS Conventional Specifications Power Supply Mains Supply voltage Nom. Operating voltage Power Supply Current Quiescent Current Zone Detection Circuit No of Zones Zone Monitoring Zone Quiescent Current No of Detectors/Circuits End Of Line Value (EOL) Max Cable Length respectively) Outputs Comms Output EXT Bell Output (monitored) Warning Sys Output (monitored) ACF Output (monitored) ASE Output (monitored) Reset/Buzzer Fire Alarm Output Relay (voltage free) Fault Output Relay (voltage free) Auxiliary DC Output (monitored) Environmental Operating Temperature Relative Humidity Hz 27 VDC 2 A (max) 40.5 ma (min) Four (4) or Eight (8) x 2-wire system Open and Short circuit 4mA, 10uF EOL 40 (max) 3K3Ω (default), 4K7Ω, 6K8Ω, 10KΩ and 10uF 3km (Based on cable resistive and capacitive values of 50Ω and 1uF RS485 (4 and 8 zone only) 1A (max) 10KΩ EOL 1A (max) 10KΩ EOL 1A (max) 10KΩ EOL 1A (max) 10KΩ EOL Output Open Collector, 40mA 15sec pulse NO, C, NC. Contact rating: 30VDC NO, C, NC. Contact rating: 30VDC 24VDC10KΩ EOL -5 to +55 C (no icing) 25% - 75% (non condensing) The Ampac ZoneSense PLUS Fire Alarm Control Panel is a versatile four or eight zone conventional panel. The user friendly navigation system provides simple operation during an emergency while also enabling complex cause and effect programming to be undertaken. A range of modular panel add-on kits allows the panel to be professionally tailored to the requirements of each installation. This means small conventional panels can now be used in a wider range of applications. ZoneSense PLUS offers you complete control. The panel can be easily upgraded and programmed on site. ZoneSense PLUS is approved to AS4428 and is available in ABS (BX1) or metal cabinets (BX20) with either four (4) or eight (8) zone conventional detection circuits Complies with AS Available in 4 Zone or 8 Zone Panels Up to 40 Conventional detectors per zone RS485 port supports a range of Add-on modules vailable in ABS (BX1) and Metal (BX20) cabinet versions Mechanical Material ABS Cabinet Metal Cabinet ABS/Blend High Impact 1.2mm Mild Steel Finish ABS Light Grey Metal Oyster Matt Ripple packed ex Batteries 3kg 8.5kg Dimensions (mm) ABS 300 H x 360 W x 100 D Metal 500 H x 405 W x 145 D Ancillary 250 H x 405 W x 145 D Item Numbers ZoneSense PLUS 4 Zone SPX1 Inc Batteries ZoneSense PLUS SP1x OWS25W Inc Batteries ZoneSense PLUS 4 Zone SP1x OWS50W Inc Batteries ZoneSense PLUS 8 Zone SP1X Inc Batteries ZonesSense PLUS 8 Zone SP1X OWS25W Inc Batteries ZoneSense PLUS 8 Zone SP1X OAWS50W Inc Batteries Ancillary Cabinet

5 8 Fire Control Panels 9 ZoneSense PLUS AR Conventional Specifications Power Supply Mains Supply voltage Nom. Operating voltage Power Supply Current Quiescent Current Zone Detection No of Zones Zone Monitoring Zone Quiescent Current No. of Detectors per Zone Zone End Of Line Value Outputs EXT Bell Output Warning Sys Output ACF Output ASE Output Fire Alarm Output Relay Fault Output Relay Auxiliary DC Output Reset/Buzzer Output Environmental Comms Output Operating Temperature Relative Humidity Hz 27 VDC 2 A (max) 40.5 ma (min) 4 or 8, 2 Wire Open and Short circuit 4mA, 10uF EOL 40 max 3K3Ω (default), 4K7Ω, 6K8Ω 10KΩ and 10uF 500mA (max) 10KΩ EOL monitored 500mA (max) 10KΩ EOL monitored 500mA (max) 10KΩ EOL monitored 500mA (max) 10KΩ EOL monitored NO, C, NC Contact: 30VDC NO, C, NC Contact rating: 30VDC 24VDC 10KΩ EOL monitored Open Collector, 40mA 15sec pulse RS485-5 to +55 C 25% - 75% non condensing The ZoneSense PLUS AR (Agent Release) Panel is a dedicated panel for agent release systems. Housed in a metal cabinet, the ZoneSense PLUS AR is available in either four (4) or eight (8) zones. Based on a ZoneSense PLUS Fire Alarm Control Panel (FACP), the AR version is fitted with an Agent Release Panel Add-on (control card and termination board) and a dual action yellow manual call point as standard. The Agent Release panel add-on option is factory set. Dedicated Agent Release system - purpose built with a host of ancillary products to suit Comprehensive system status the AR panel includes a number of system status indicators that facilitates ease of operation and maintenance Local Control Station with control and indication mimics full status of the Agent Release panel. An outdoor version of this product is available User interface and operation based around Industry Fire Emergency procedures ensures that the system installed is intuitive and easy to use Dual action Manual Call Point the yellow MCP is a break glass type and requires a dual action to be activated i.e. lift the protective transparent cover and break the glass Agent Release Panel is compliant with AS4214 Dedicated Agent Release Inputs and Outputs Pressure Switch Input Low Pressure Switch Input Interlock Input Gas Fired Output System Inoperative Output Stage 1 Relay Output Stage 1 Monitored Output Stage 2 Relay Output Stage 2Monitored Output Release Initial Agent Output Release Reserve Agent Output Mechanical Material Finish Cabinet Dimensions (mm) Ancillary Cabinet Dimensions (mm) packed ex Batteries Item Numbers Monitored Input Monitored Input Monitored Input Volt Free Changeover 1A@24VDC Volt Free Changeover 1A@24VDC Volt Free Changeover 1A@24VDC 1Amp 10KΩ EOL ( reversal) Volt Free Changeover 1A@24VDC 1Amp 10KΩ EOL ( reversal) Monitored current limited 2A max Monitored current limited 2A max 1.2mm Mild Steel Ripple 500(H) x 405(W) x 150(D) 250(H) x 405(W) x 145(D) Metal 8.5kg ZoneSense PLUS 4 Zone SP1X Agent Release Inc Batteries ZoneSense PLUS 8 Zone SP1X Agent Release Inc Batteries

6 10 Fire Control Panels 11 LoopSense Intelligent Specifications Power Supply (General) SP1X P8X Dimensions 00H x 405W x 150Dmm 845H x 515W x 175Dmm 9kg 15kg Power Supply 3 Amp PSU version 5 Amp PSU version Maximum Battery Capacity 26Ah 40.0Ah Input VAC Output 27.5VDC +/- 0.1VDC Battery Discharged Cut Off 21VDC 21VDC Material 1.2 mm steel Finish Surf Mist Ripple Loop Quiescent Current(1 Loop Panel) 115mA Quiescent Current (2 Loop Panel) 135mA Loop Capacity 500mA max Max No of Detectors/Devices per Loop 126 Cabling Requirements 2 core 1.5 to 2.5 mm2 Fault supervision O/C, S/C, overcurrent Outputs/Inputs Outputs (SupervisedProgrammale) Relay outputs (Programmable) Open Collector Output (Programmable) Auxiliary VDC(Programmable) Inputs (Programmable) 4 x 500mA max 3 x free 1A 2 x 30mA 2 x 500mA 4 x O/C, S/C, 10K EOL Communications Port Internal to LoopSense RS485 External to LoopSense RS485 Printer port RS232 or Parallel PC Interfacing RS232 or USB 2.0 Environmental -5 C to +55 C (no icing) 25% to 75% (non condensing) IP30 LoopSense is an Intelligent Analogue Addressable Fire Alarm Control Panel. Available in one or two loops, the LoopSense comes packed with options and features that facilitate flexibility, ease of installation and commissioning. Complies to AS7240-2:2004, AS7240-4:2004, and AS4428-3:2010 -ActivFire listed Clear back-lit 240 x 64 graphic LCD 500mA loop current Advanced balanced loop design for noise rejection Auto learn facility Supports extensive range of Add Ons, including the SmartTerminal Repeater User friendly Loopmaster programming software tool Laptop connection using USB2.0 or RS232 serial port Available in ABS (BX1) and Metal (BX10) cabinet versions Item Numbers LoopSense 1 Loop 3A SP1X LoopSense 1 loop 6A SP8X LoopSense 2 Loop 3A SP1X LoopSense 2 Loop 6A SP8X LoopSense 1 Loop 3A SP1X OWS LoopSense 2 Loop 3A SP1X OWS LoopSense 1 Loop 3A SP1X OWS LoopSense 1 Loop 6A SP8X OWS LoopSense 2 Loop 6A SP8X OWS

7 12 Fire Control Panels 13 FireFinder PLUS Intelligent Specifications Power Supply (Gereral) Cabinet SP1X Cabinet SP8X/SP16X Power Supply 5A PSU version 5A PSU / 22A PSU Version Input VAC VAC Protection 2 Amp 3AG 2 Amp 3AG (5A PSU)/ 5 Amp 3AG (18A PSU) Output Current 5.6 Amps 22 Amp Charger Current 1.25A 1.25A / 3A Maximum Battery Capacity: 26Ahr 40Ahr Charger Output : /- 0.1VDC Battery Type: 2 x 12V Sealed Lead Acid Discharge Cut-off voltage: 21VDC Loop Panel Quiescent Current 1 Loop 220mA Additional Loops (even) +40mA for each Loop Additional Loops (odd) +75mA for each Loop Loop Capacity 500mA max per Loop Max No of Devices per Loop 126 Cabling Requirements 2 core 1.5 to 2.5mm² Fault supervision O/C, S/C, Over current Inputs/Outputs Outputs (Programmable) Relay outputs (Programmable) Auxiliary Power Outputs Inputs (Programmable) 4 x 1 Max, 10K EOL 5 x Free - 24VDC@1Amp 2 x 500mA 4 x O/C, S/C, 10K EOL Communication Comms External to FACP RS485 Comms Printer port RS232 or Parallel Comms PC Interface RS232 or USB 2.0 Environmental Temperature -5ºC to + 40ºC Humidity 25% to 95% (non-condensing) FireFinder Plus is an Intelligent Analogue Addressable Fire Alarm Control Panel that is available in 1 to 8 loop panel options. The FireFinder Plus is suitable for medium to large sized fire detection systems and is compatible with Apollo XP95, Discovery and Series 90 detectors. Powerful and flexible programming is achieved via AMPAC s configuration tool ConfigManager Plus which includes many dedicated pre-engineered programming functions. Simple system programming is easily achieved via the front panel. FireFinder Plus is configurable as a peer to peer network up to 100 panels/nodes with a maximum of 150 Loops. Fully approved to AS2740-2, AS720-4 and AS4428.3:2010 Fully Expandable 1 to 8 Loop Fire Alarm Control Panel Large Graphic (240 x 64 pixel) Display 500mA Loop Current 4 Programmable Monitored Inputs 4 Programmable Monitored Outputs 5 Programmable Relays 2 Auxiliary Power Outputs Programmable via front panel Networkable Supports High Level Graphics Interface Supports a Range of Panel Add-ons Mechanical Material Colour/Finish Dimensions (mm) SP1M SP1X SP8X SP16X IP Rating Item Numbers 1.2mm Mild Steel Surf Mist Ripple 500H x 405W x 150D 500H x 405W x 150D 845H x 518.5W x 173D 1200H x 625X x 240D IP30 (Indoor Use Only) (Addressable) FireFinder PLUS 1 Loop 5A SP1X FireFinder PLUS 1 Loop 5A Agent SP FireFinder PLUS 1 Loop OWS25 5A SP FireFinder PLUS 1 Loop OWS50 5A SP FireFinder PLUS 1 Loop 5A SP8X FireFinder PLUS 1 Loop Agent 5A SP FIREFINDER+ 1 Loop AGENT 5A SP FIREFINDER+ 1 Loop OWS50 5A SP (Conventional) FireFinder PLUS 8 Zone 5A SP1X FireFinder PLUS 8 Zone OWS25 5A SP FireFinder PLUS 8 Zone OWS50 5A SP

8 14 Fire Control Panels 15 FireFinder Intelligent Specifications Power Supply Finish Material Input Output Output Current Battery Type Arch White Ripple 1.2mm steel 85 to 264Vac (47-63Hz) 27Vdc 2A, 5.6A or 18A 2 x 12V SLA batteries Loop Quiescent Current 240mA (min 1 Loop no load) Devices per Loop 126 Loop Current 250mA Devices per Zone 40 Conventional Zone EOL 3K3 Cable (Loop and Conventional Circut) 2 core 1.5 to 2.5mm² FireFinder is a state of the art multi microprocessor controlled Intelligent Fire Alarm Control Panel. Modular in design, the FireFinder provides flexibility and versatility that can be configured to operate with both intelligent analogue addressable and conventional devices in the one system. Available in single loop or multiple loop configurations, the FireFinder supports the leading Apollo XP95 and Discovery detector protocols. The Ampac ConfigManager software tools provide a powerful combination with the FireFinder to configure the system operational and functional characteristics of an installation. Enhanced networking capabilities offer the user extended applications with FireFinder incorporating a Master/ Slave Fire control panel arrangement, true Peer to Peer systems, data gathering panels and SmartGraphics a PC based application for the supervision, monitoring and control of larger fire management systems. Complies with AS and AS Clear back-lit 40 character 8 line LCD display Programming options via the front panel or laptop computer Remote system interrogation and diagnostics Extensive Alarm Management resources Self Auto Learn capabilities Day Night sensitivity settings Versatile multi processor architecture Event log and printer options SPOT Single Person Operation Test Flexible modular expansion and panel Add Ons Optional 32, 64, 96 & 128 zone indicators SmartTerminal repeater options Outputs/Inputs Outputs Bell 1 Bell 2 Plant Monitored Plant Un-Monitored Warn Sys Monitored Warn Sys Un-Monitored Fault Monitored Fault Un-Monitored Isolate Alarm Valve Monitor Batt Fail (normally energised) Battery Output Aux Power Output 1 Aux Power Output 1 EV40 use Aux Power Output 2 DBA/MCP 2 Amp Fused 2 Amp Fused 1 Amp Fused, 10K EOL 1 Amp voltage free contact 1 Amp Fused, 10K EOL 1 Amp voltage free contact 1 Amp Fused, 10K EOL 1 Amp voltage free contact 1 Amp voltage free contact 1 Amp voltage free contact 1 Amp voltage free contact 1 Amp voltage free contact Protected 1 Amp Fused 3 Amp Fused 1 Amp Fused Monitored 10K EOL Environmental Temperature 5ºC to + 55ºC Humidity 25% to 75% (non-condensing) IP Rating IP51 Item Numbers (Conventional) FireFinder SP1X 16 Zone AS FireFinder SP1X 16 Zone ASE FireFinder SP1X 16Zone OWS FireFinder SP1X 16Zone OWS FireFinder SP1X 16Zone (Addressable) FireFinder SP1X 1Loop AS FireFinder SP1X 1Loop ASE FireFinder SP1X 1Loop OWS

9 16 Fire Control Panels 17 Add Ons (*FF+ - FireFinder PLUS compatable, *FF - FireFinder compatable, *LS - LoopSense compatable, *ZSP- ZoneSense PLUS compatable) Analogue Loop Upgrade Kit *FF+ This kit adds an intelligent analogue loop to the FireFinder PLUS Control Panel For an odd numbered loop upgrade the kit consists of an I/O CPU module, cable and termination card An even numbered loop upgrade consists of an I/O CPU module and cable Loop current 24 VDC 40 ma 500 ma max. -5 C to +55 C (no icing) 200 grams FireFinder Plus Slave CPU Board FireFinder Plus Term Board FireFinder Terminal Repeater SmartTerminal Repeater *FF+ *LS *FF The SmartTerminal has been designed to display the status of and provide limited controls for the FireFinder Plus and LoopSense Fire Alarm Control Panels (FACP) in m Operating Internal (24Vdc) V DC External (240Vac) VAC Quiescent Current 12.5mA (backlight off, buzzer off) Maximum Current 43.8mA (backlight on, buzzer on) Temperature -5ºC to + 55ºC Humidity 25% to 75% (non-condensing) Cabling Requirements 2 core 1.5 to 2.5mm² External Power Supply 1.8A plus 400mA Battery Charging ( only) Battery Size 3.2AHr ( only) Material ABS Dimensions BX (H) x 325 (W) x 50 (D) BX1 300 (H) x 360 (W) x 100 (D) Loop Module Expansion Kit *FF+ Expands the capacity of the FireFinder to accommodate a further four loops, 64 conventional zones, four I/O modules or any combination of the above Requires a main controller board 24 VDC 5 ma -5 C to +55 C (no icing) 110 grams LoopSense/FireFinder Plus Terminal Repeater FireFinder FF SmartTerminal (BX1 enclosure) FF SmartTerminal inc PSU (BX1 enclosure) FF SmartTerminal (BX05 slimline enclosure) FireFinder Plus and LoopSense FF+/LS SmartTerminal (BX1 enclosure) FF+/LS SmartTerminal inc PSU (BX1 enclosure) FF+/LS SmartTerminal (BX05 slimline enclosure) Wall Mount Surround FireFinder Plus Loop Expansion Board Wire Network Interface Board *FF+ Supports Redundant Network, with Isolated Network In and Out Ports Up to 99 Network Nodes Baud Rate Distance Between Nodes 1.2km Uses Industry Standard RS485 Diagnostic LEDs Quiescent Current Protocol Max distance (between NICs) Cable requirements 27 VDC 41 ma RS km 2 Core Screened Fire Resistant -5 C to +40 C Network Interface Card 2 Wire High Level Interface Expander or Port Expander Board *FF+ *LS *FF Building Management Paging system Nurse Call Systems SmartGraphics MODBUS Max current Relay contact rating 24 VDC 2.4 ma 80 ma 1 amp at 24 VDC -5 C to +55 C (no icing) 130 grams High Level Interafce - Factory Fitted High Level Interface - Add-On Kit

10 18 Fire Control Panels 19 Add Ons 8 Way Relay Board *FF+ *LS *ZSP Provides volt free change over contacts 8 relay outputs per board Remote version available DIN Mount chassis Remote version communication via RS485 serial link Max current Relay contact rating 24 VDC 2.4 ma 80 ma 3 amp at 24 VDC -5 C to +55 C (no icing) 130 grams Relay Board Relay Board (Remote) Zone Conventional Board *FF+ *LS Supports up to eight conventional zones Selectable end of line device 3K3, 4K7, 6K8, 10K or 10µF capacitor Supports head removal requirement on each zone Supports up to 40 conventional devices per zone circuit (ORBIS/Series 65) Programmable latching and non-latching (self-resetting) input on each zone circuit Alarm current Size 24 VDC 15mA (including capacitive EOL current) plus device current 43mA (one circuit in alarm) -5 C to +55 C (no icing) 72.5 x 155mm 120 grams 8-way Sounder Board *FF+ *LS *ZSP Provides 8 monitored switched 24 VDC outputs per board Max 1 per FireFinder PLUS Max current Output rating (ea) EOL Monitoring Value Fire Fan Module *FF+ *LS *FF *ZSP Four (4) Controls per Module Status indication for Run / Fault / Stop Controls for On / Auto / Off Audible and visual feedback of button press Built in Plant Trip Reset Supports 3, 4 and 5 Wire Connections Available in Hard Wired or loop driven versions Operating Dimensions Controller Card Termination Board Contact Rating Approval 24 VDC 5.6 ma 26 ma 500 ma at 24 VDC 10k Ω -5 C to +55 C (no icing) 100 grams Sounder Board VDC Fits standard Panel Cut-Out 155mm x 72mm 24VDC AS1668 Hard Wired (Includes controls and termination board) Loop Driven (Controls only) Zone Conventional Board Zone Indicator Card *FF+ *LS 16 way Input Board *FF+ *LS *ZS Provides inputs for sprinkler pumps, tanks, valves, shutdowns, etc 16 inputs per board Inputs map to relays or indicators Programmed via the LoopMaster Max current Output rating 24 VDC 2.6 ma 45 ma 0.5 amp at 24 VDC -5 C to +55 C (no icing) 120 grams Provides 32 Zone LED s capable of indicating zone Fire, Disabled, Fault and Dependency B. Suitable for use with the FireFinder range of FACP s Suitable for use with LoopSense FACP Customisable zone identification label Fully programmable via LoopMaster Max current Output rating 27 VDC 3.6 ma 8mA 0.5 amp at 24 VDC -5 C to +55 C (no icing) 100 grams Input Board Zone Indicator Card

11 20 Fire Control Panels 21 Add Ons Zone Disable and Indicator Module *FF+ *LS *FF Provides 8 Programmable Zone Disable Switches Provides 8 Status LEDs Customisable Switch Identification Label Max current Communication 27VDC 3.6 ma 8 ma RS485-5 C to +55 C (no icing) 100 grams Zone Disable & Indicator Module Switch/Indicator Module *FF+ *LS *ZSP 8 x Push Button On / Off switches Controls and Monitors solenoid test switches, manual shutdowns and etc Programmable via the ZoneSense PLUS front panel Programmable via ConfigManager for the FireFinder range of panels Programmable via LoopMaster for the LoopSense range of panels Max current Relative Humidity 24 VDC 3.6 ma 8 ma -5 C to 55 C (no icing) 100 grams Agent Release Module *FF+ *LS *FF *ZSP Compliance with AS4214 Controls & Monitors Agent release system Outputs for warning signs & activation devices Inputs for signals from pressure switches & valves Serial connection to Agent release (LCS) Local control Station Programmed via the FACP front panel Location or title descriptor label Pressure Switch Input Low Pressure Switch Input Interlock Input Gas Fired Output System Inoperative Output Stage 1 Output Stage 2 Output Release Initial Agent Output Release Reserve Agent Output System Capacity FireFinder LoopSense ZoneSense Plus Monitored Input Monitored Input Monitored Input Volt Free Changeover 1A@24VDC Volt Free Changeover 1A@24VDC Monitored Monitored Monitored current limited 2A max Monitored current limited 2A max 8 Maximum 8 Maximum 1 Maximum Agent Release Module Switch/Indicator Card Fire Brigade Board *LS ZSP Provides common outputs for connection to fire brigade signalling equipment 5 outputs Alarm, Fault, Isolate, Battery Fail and 2nd Alarm Max current Output rating 24 VDC 9 ma 52 ma 1 amp at 24 VDC -5 C to +55 C (no icing) 110 grams Fire Brigade Board Agent Release- Local Control Station *FF+ *LS *FF *ZSP Remote Agent release LCS Complies with AS4214 For use only with Agent release Module Double Action manual Agent release facility Toggle between initial & reserve agent Can install up to 8 x LCSs per panel Local Control Station Network Interface Card (NIC)- 2 Wire Network *FF The NIC gives the FireFinder network capabilities via the RS422 communications port Provides an additional RS232 communications port when connected to Controller Interface Card (CIC) High level interface for Building Management or ModBus protocol for SmartGraphics and PLCs The NIC can be isolated from other network devices Loop In/Loop Out for easy installation Quiescent Current Available Ports Max distance (between NICs) Cable requirements 24 VDC 65 ma RS422 network RS232 serial comms 1.2km RS485 1 pair twisted/screened RS232 1 pair twisted/screened -5 C to +55 C (no icing) 225 grams SP1X SP8X SP16X/Rack Add-On Kit

12 22 Fire Control Panels 23 Add Ons Module Expansion Kit for Modules (5-8) *FF Expands the capacity of the FireFinder to accommodate a further four loops, 64 conventional zones, four I/O modules or any combination of the above Requires a main controller board 24 VDC 5 ma -5 C to +55 C (no icing) 110 grams SP8X Loop Module Expansion Kit SP16x/Rack Loop Module Expansion Kit Way 5A Relay *FF Each upgrade panel add-on offers 8 voltage free relay outputs. Each output is rated at 5 amps, 24 VDC Each relay has a single normally open/close volt-free contact extended to a wireprotected screw terminal The standard 8-way relay upgrade requires spare capacity available on a 128/128 I/O and 16/16 I/O module Relative Humidity 24 VDC 5 ma (Serial Relay Board) -5 C to 55 C (no icing) 190 grams SPX 8-Way 5A O/P Relay Rack 8-Way 5A O/P Relay Way Serial Relay Output Board *FF Each serial relay output board offers 8 voltage free relay outputs, each rated at 5 amps, 24 VDC Each relay has a single normally open/close volt-free contact extended to a wireprotected screw terminal The serial 8-way relay is driven directly from the main controller board Relay output current 24 VDC 5 ma 5 Amps at 24 VDC -5 C to +55 C (no icing) 190 grams Rack 8 Way Serial Relay Output Board SPX8 8 Way Serial Relay Output Board Way Bell Monitor Board *FF The 8-Way Bell Monitor has 8 switched 24V DC sounder outputs The outputs are programmable and monitored for open or short circuit The board connects directly to the main controller board Max sounder output current Max output current 24 VDC 20 ma 1 Amp each 4 Amps per board -5 C to +55 C (no icing) 250 grams 8 Way Bell Monitor Board Plus 4 Bell Monitor *FF The 4 Plus 4 Bell Monitor has screw terminals for 4 voltage free contacts and 4 switched 24V DC sounder outputs The outputs are programmable and monitored for open or short circuit The board connects directly to the main controller board RS422 RS VDC Quiescent Current 65 ma Available Ports Network Serial comms Max distance (between NICs) 1.2km Cable requirements 2 pair twisted/screened 1 pair twisted/screened -5 C to +55 C (no icing) 225 grams 4 Plus 4 Bell Monitor Board Way Conventional Zone Card *FF Adds 16 conventional Alarm Zone Circuits Kit consists of an I/O CPU module, cable and 16 zone termination card Supports up to 40 conventional detectors (Series 60, Series 65 or Orbis) per zone Fixed 3K3 End-Of-Line device 24 VDC 145 ma -5 C to +55 C (no icing) 185 grams SP8X/SP16X 16 Way Conventional Zone Card Rack 16 Way Conventional Zone Card

13 24 Fire Control Panels 25 Add Ons 16 Opto Inputs *FF The Opto Input panel add-on provides 16 programmable electrically isolated inputs to the FACP The input from a third party source should be a volt-free contact This upgrade requires spare capacity available on a 128/128 I/O and 16/16 I/O Interconnect Module Relative Humidity 24 VDC 5 ma -5 C to 55 C (no icing) 185 grams SP 16 Opto Input Rack 16 Opto Input Panel Mounted LED Indicators *FF Provide flexibility to include additional LED indicators to the FireFinder SP1X and SP8X Available in three versions: 32 zone alarm only indication (red) 16 zone alarm/fault indication (red/amber) 32 zone general indication (amber) Serial connection to the FireFinder panel Simple clip installation Indicators remain illuminated until reset by the panel Indicators are tested by the FireFinder panel s lamp test control Max current 27 VDC 30 ma 40 ma -5 C to +55 C (no icing) 100 grams Remote Mounted LED Indicators *FF The remote LED indicator boards provide facilities to mimic the FireFinder zone LEDs and switches Connects to the RS485 communications bus via the controller interface card Allows the custom design of geographic site layout mimics Each termination board connects up to 32 zone LEDs 31 boards maximum total 992 zone indications Max current Communication mode Baud rate Communication cable No. of boards No. of zones Buzzer external max current On board status indication Common inputs 27 VDC 8 ma max 100 ma RS max 1 x pair twisted and screened 31 max 992 zones max 20 ma Power on green Normal green Fault yellow Reset Lamp test Buzzer mute Bell isolate Manual evacuate -5 C to +55 C (no icing) FireFinder LED Mimic Driver 32 Way Mimic Output Termination Board FireFinder 16 Zone LED Display Board FireFinder SP1X 32 Zone Alarm Only Indication (Red) FireFinder SP8X 32 Zone Alarm Only Indication (Red) FireFinder SP1X 16 Zone Alarm/Fault Indication (Red/Amber) FireFinder SP8X 16 Zone Alarm/Fault Indication (Red/Amber) FireFinder SP1X 32 Zone General Indication (Amber) FireFinder SP8X 32 Zone General Indication (Amber) Modem *FF The modem allows a remote access to FireFinder Configuration and application software can be uploaded or downloaded via the modem Wireless Modem requires available signal from appropriate network All modems are AUSTEL approved Great tool to provide remote support 27 VDC Data transfer rate 9600 baud max Comms to FACP RS C to 55 C (no icing) Relative Humidity SP & Rack: 1kg Wireless: 5kg SPX Modem Rack Modem Wireless Modem

14 26 Fire Control Panels 27 Add Ons Fibre Optic Network Interface *FF 4 versions available to suit your cabling scheme on site Redundant loop integrity (same as copper) A network interface card is still required at each FACP node Maximum distance using Multimode (between nodes) up to 5km; using Single Mode 50km Supply Quiescent Current Optical Connector Ports Available Size (mm) Operating Temperature Humidity 24 VDC VDC ST standard RS422/RS D x 104W x 25H 280g -20 C to +75 C 0 to 95% relative, non-condensing FireFinder Fibre Optic Multimode 2 Core FireFinder Fibre Optic Multimode 1 Core FireFinder Fibre Optic Single Mode 2 Core FireFinder Fibre Optic Single Mode 1 Core Panel Printer *FF+ *LS *FF The dot matrix printer provides hardcopy activity report Alarms, faults, isolates and system logs may be printed 3 colour status LED Self test mode Easy maintenance for replaceable ribbon cassette and paper roll Character size 5 VDC 5 VDC 5 x 7 dots -5 C to +55 C (no icing) 25 to 95% (non condensing) 380 grams Printer C/W Mounting plate (Suit Australian White SP1 cabinet) Printer C/W Mounting plate (Suit Australian) Paper Rolls (10) MIS1981 Ribbon MIS1982 Analogue Loop Upgrade Kit *FF This kit adds an intelligent analogue loop to the FireFinder Control Panel For an odd numbered loop upgrade the kit consists of an I/O CPU module, cable and termination card An even numbered loop upgrade consists of an I/O CPU module and cable Loop current 24 VDC 40 ma 250 ma max. -5 C to +55 C (no icing) 200 grams 1 Loop Upgrade Kit- even numbered loop SP1X Loop Upgrade Kit and Processor- odd numbered loop SP1X Even No. Loop SP16X/Rack Even No. Loop SP Odd No. Loop SP16X/Rack

15 28 Alarm Systems 29 Standalone Occupant Warning Panel Item Numbers EvacU 25W 3A EvacU 50W 3A EvacU 100W (2 x 50W) 5A EvacU 150W (3 x 50W) 10A EvacU 200W (4 x 50W) 10A Handheld Microphone OWS Dual XENON Dual LED Beacon Shallow Base Dual LED Beacon Deep Base Zone Indicator Module An optional Zone Indicator module is available when more than one emergency zone is programmed and the user requires individual Zone Alarm, Alert, Evacuation and Fault indications The Zone Module also provides the ability to select and broadcast live speech to individual emergency zones Quiescent Current 10.5 ma The Ampac EvacU is a fully self-contained Occupant Warning System. Systems are available from 25W up to 200W and incorporate Ampac s new range of Class D 25N & 50N Amplifiers, Control & Indicating modules and Line splitters. Zone Indicator Module OWS Up to eight Emergency zones and eight seperate Paging Zones can be configured using the dedicated EvacUwiz programming tool. Highly Efficient Class D Amplifier Technology Alert and Evacuation Signals to AS Speaker Line Fault Monitoring and Protection Monitored Strobe Output Dedicated Emergency Microphone Input Secondary BGM and PA Analogue Audio Input False Alarm, System Test and Lock Down Messages Custom Messages Up to 8 Emergency Zones 8 Zone Remote Paging console Specifications 4 Way Line Splitter A four way Line splitter provides the ability to have a single emergency zone split into 4 separate monitored branches When a remote paging console is connected each split can be assigned to separate paging zones Up to two splitters can be connected to a single amplifier with a maximum of four splitters per system Quiescent Current 100V Line outs Monitoring EOL 10.5mA 4 (Max 100W each to a max of 250W total) 10K 47K Ω 4 Way Line Splitter OWS Power Supply (General) Power Supply Battery Size Max (Battery box may be required) Cabinet Dimension (mm) Amplifiers Amplifiers (Audio) 25W (Max 4) 50W (Max 4) Amplifiers (Visual) Strobe Output Strobes Xenon Strobes LED Amplifiers Audio O/P Emergency Zones Front Controls (Max 1) 3, 5 or 24V 17 Ahr (depends on No. of Amplifiers fitted) 500(H) x 405(W) x 150(D) Current Quiescent / Alarm 20 ma / 1.19 A each 20 ma / 2.39 A each 1A Max per Amplifier Max 8 sets Max 40 sets 100Vac Up to 8 max 10.5 ma Quiescent 8 Zone Paging Console The Remote Paging Console allows up to 8 individual paging zones to be programmed when a combination of more than one amplifier and/or Line Splitters are included in the system Additionally the RPC includes a back ground music input which can be programmed to each zone via the Remote Paging Console Quiescent Current 5.5 ma Number of Zones 8 BGM Input Source 3.5mm Audio Jack Cable CAT5 RJ45 connection Cable Distance 100m 8 Zone Paging Console OWS

16 30 Alarm Systems 31 Occupant Warning System Add-Ons The Ampac Single Zone Occupant Warning System is available with a 25 Watt and 50 Watt audio output with an optional front panel control. The alert and evacuation signals are compliant to AS including voice messages as standard. The speaker circuit is protected and monitored for shorts and interruptions. Up to three spur lines (branches) are supported. A monitored strobe output is provided as standard which i supports both xenon and led strobes. Each audio source (alert / evacuation signals, emergency paging and secondary analogue audio input) has a dedicated volume control. Three programmable relays are provides, which default to fault, volume control override and test mode.the optional front panel control has an integrated emergency microphone (and can optionally support a hand held microphone) The Single Zone Occupant Warning System is suitable for use in Ampac s FireFinder, LoopSense and ZoneSense Plus Fire Alarm Control Panels. Available in 25Watt and 50Watt versions Alert and Evacuation Signals to AS Speaker Line Monitoring and Protection Monitored strobe output Volume Control Dedicated emergency microphone input Secondary analogue audio input Programmable evacuation strategies False Alarm, System test and Lock Down Messages Three programmable output relays 25 W& 50W OWS 25watt 50watt Max. Curret (full audio load, no strobe load) 1.19Amps 2.39Amps Supply 27VCD (nominal) Quiescent Current (no audio load, no strobe load) 20mamps Strobe Output (Xenon) 8 sets ( ) Strobe Ouput (LED) 40 sets ( /6) Audio Output 100VAC Temperature -20 to +70 C Humidity 0-95% non-condensing Alert / Evac Changeover time (secs) Alert only, Evac only, 60, 90, 120, 180, 300 or under manual control Speaker EOL Nominal 47KΩ 5% 1/3 Watt THD 0.12% 0.89% Signal to Noise Ratio 80.5dB 82.1dB Alert Signal To AS including voice Evacuate Signal To AS including voice Amplifier (L x W x H) 100 x 77 x 35mm OWS 50W Amplifier OWS 25W Amplifier OWS Indicator & Controls W OWS Supply 27VDC (nominal) Max Audio Load 120Watt Quiescent Current (no audio load, no strobe load) 240mAmps Max. Current (full audio load, no strobe load) 8Amps Strobe Output (Xenon) 8 sets ( ) Strobe Output (LED) 40 sets ( /6) Audio output voltage 100VAC Temperature -20 C to 70 C Humidity 0-95% non-condensing Alert / Evac Changeover time (secs) Alert only, Evac only, 60, 90, 120, 180, 300 or under manual control Speaker EOL Nominal 47kΩ 5% 1/3 Watt THD <0.6% Signal to Noise Ratio 91dB Amplifier Dimension(L x W x H) 170mm x 210mm x 85mm OWS 120W Amplifier OWS Indicator & Controls W OWS Supply 27VDC (nominal) Max Audio Load 250Watt Quiescent Current (no audio load, no strobe load) 380mAmps Max. Current (full audio load, no strobe load) 17 Strobe Output (Xenon) 8 sets ( ) Strobe Output (LED) 40 sets ( /6) Audio output voltage 100VAC Temperature -20 C to 70 C Humidity 0-95% non-condensing Alert / Evac Changeover time (secs) Alert only, Evac only, 60, 90, 120, 180, 300 or under manual control Speaker EOL Nominal 47kΩ 5% 1/3 Watt THD <0.6% Signal to Noise Ratio 91dB Amplifier Dimension(L x W x H) 300mm x 240mm x 95mm OWS 250W Amplifier OWS Indicator & Controls w OWS Supply 240VAC/27VDC (nominal) Max Audio Load 500Watt Quiescent Current (no audio load, no strobe load) 500mAmps Max. Current (full audio load, no strobe load) 35Amps Strobe Output (Xenon) 8 sets ( ) Strobe Output (LED) 40 sets ( /6) Audio output voltage 100VAC Temperature -20 C to 70 C Humidity 0-95% non-condensing Alert / Evac Changeover time (secs) Alert only, Evac only, 60, 90, 120, 180, 300 or under manual control Speaker EOL Nominal 47kΩ 5% 1/3 Watt THD <0.5% Signal to Noise Ratio 90dB Amplifier Dimension(L x W x H) 83mm x 380mm x 88mm OWS 500W Amplifier OWS Indicator & Controls

17 32 Alarm Systems 33 EV3000 Emergency Control Panel Specifications Mechanical Material Finish Dimensions Approvals Signals Electrical Power Supply Communication EWS Zones EIS Zones Paging Console ECP s Visual Warning Option 1 Option 2 1.6mm Mild Steel Powder Coated Arch White 10U 700H x 625W x 240D mm (SECP only) 12U 900H x 650W x 290D mm 16U 1200H x 700W x 375D mm 29U 1800H x 700W x 375D mm SSL AS Compliant with AS1670.4: , 13, 19.5 or 26 A 24 VDC 9600 bps 144 max 288 max 8 max (recommended) 12 max (recommended) EV3000 Visual Outputs Maximum of 8 pairs per visual circuit (for Xenon ). Not T3 compliant EV3000 Visual Outputs Maximum of 40 pairs per visual circuit (for LED ). T3 compliant Note: The LED visual pairs require the Ampac Visual Driver Kit fitted The Ampac EV3000 Occupant Warning and Intercom System is designed for the purpose of enabling the orderly evacuation of occupants, from a building or structure, in the event of an emergency. The system comprises of two (2) sub-systems. The first being the Occupant Warning System (OWS) and the other the Occupant Intercom System (OIS). While the Warning and Intercom System have separate controls, they coexist in a Apanel that is logically presented and aesthetically pleasing. The Occupant Warning System makes use of speakers strategically placed around the site, to broadcast ALERT, and/or EVACUATION signals or public address announcements. The OWS may be automatically initiated or manually operated. When not used in an emergency situation, the EV3000 can broadcast background music and/or general paging announcements. The Occupant Intercom System (OIS) consists of front panel control at the Emergency Control Panel (ECP) and Warden Intercom Phones (WIP) that are strategically placed throughout the building. Communication is only possible between the WIP and ECP. Item Numbers EV U 1 AMP RACK + FIRST EV U 1 AMP RACK + FIRST EV U 1 AMP RACK + FIRST EV U DBL CABINET 1 AMP EV U SECP C/W FIRST EV U SECP C/W FIRST EV U SECP C/W FIRST EV U SECP C/W FIRST For larger sites, multiple control panels may be networked. ABS (BX1) and Metal (BX10) cabinet versions. Network System Modular System Design. Discrete Front Panel Controls. 40, 120, 240 & 480 Watts Amplifiers to suit your need. Visual Output for Hearing Impaired or Noisy Environments. Common or Individual Fire Alarm Inputs. Common or Zoned Background Music Inputs. Monitoring of Speaker Circuits. Monitoring of Visual Warning Indicators. Automatic Volume Control incorporating Ambient Noise Sensing Microphone. Stand-by Signal Generators. Digital Paging Console

18 34 Alarm Systems 35 EV3000 Emergency Control Panel - Add Ons 40 Watt Power Amplifier A modular power amplifier that is rated at 40 watts Multi-channel audio input supports Alert tone, Evacuation tone, Public Address, and background music Continuous monitoring of amplifier and 100 volt speaker circuit Overload protection with Automatic Easily plugs into an Ampac EV3000 amplifier frame Can fit up to 8 amplifiers per frame Max current Max output power Output voltage Freq. Response Distortion Sensitivity 24 VDC 58mA 3400mA 40 Watts 100 VAC RMS 150Hz to 12kHz (±1dB) Max 1% at full load (typical 0.5%) +5dB <200Kohm balanced) (1.4VRMS) Overload 100 VRMS + 10% 675 grams 40 Watt Power Amplifier Watt Power Amplifier 24v DC supply Mother board address strapping (120 address positions) Continuous fault monitoring Volume override output Test tone input Data selectable 4 channel input (balanced) Tone generator synchronisation input Indication (power on - green, power shutdown - yellow, amp or line fault - red, overload - red) Minimum cable size 2.5mm² 24 VDC 350mA Max current 16200mA Max output power 240 Watts Output voltage 100 VAC RMS Freq. Response 210Hz to 14.5kHz (±1dB) Distortion < 0.2% at full load Signal to Noise 77 db Overload 100 VRMS + 10% 2320 grams 240 Watt Power Amplifier Watt Power Amplifier A modular power amplifier that is rated at 120 watts Multi-channel audio input supports Alert tone, Evacuation tone, Public Address, and background music Continuous monitoring of amplifier and 100 volt speaker circuit Overload protection with Automatic Easily plugs into an Ampac EV3000 amplifier frame Can fit up to 4 amplifiers per frame 24 VDC 175mA Max current 8100mA Max output power 120 Watts Output voltage 100 VAC RMS Freq. Response 210Hz to 14.5kHz (±1dB) Distortion < 0.2% at full load Signal to Noise 77 db Overload 100 VRMS + 10% 1160 grams 120 Watt Power Amplifier Watt Power Amplifier 24v DC supply Mother board address strapping (120 address positions) Continuous fault monitoring Volume override output Test tone input Data selectable 4 channel input (balanced) Tone generator Indication (power on - green, power shutdown - yellow, amp or line fault - red, overload - red) Minimum cable size 4mm² 24 VDC 700mA Max current 32400mA Max output power 480 Watts Output voltage 100 VAC RMS Freq. Response 210Hz to 14.5kHz (±1dB) Distortion < 0.2% at full load Signal to Noise 77 db Overload 100 VRMS + 10% 4640 grams 480 Watt Power Amplifier

19 36 Alarm Systems 37 EV3000 Emergency Control Panel - Add Ons Emergency Alarm Intiating Device (EAID) Connects to S004 WIP 2 wires for WIP & EAID Compatible with Emergency Alarm Initiating Device (EAID) Warden Intercom Phone- 2 Wire (S0004) 2 Wire WIP/EAID wiring High quality WIP audio Complies with AS Suitable for models manufactured after July 2010 Operating Line Current draw Line Impedance Line Level Cabling Dimensions 27 VDC (line driven) On hook - 25 VDC max Off hook - 14 VDC max On hook - 5 ma max Off hook - 35 ma max 360 ohm balanced 0 db (± 3dB) 2 wire - 2.5mm² max. 215H x 85W x 62D mm 380 grams Warden Intercom Phone 2 Wire (S0004) WIP Enclosure Metal Surface Mounted Warden Intercom Phone - 3 Wire Remote Paging Console Provides a point to initiate a non-emergency voice announcement via the EV3000 Provides a pre-announcement tone Easy keypad operation to broadcast voice announcements to selected zones, or group of zones Connects to EV3000 via RS485 Derives power from the EV3000 panel Size 80H x 300W x 220D mm Supply voltage 12 VDC Current 400 ma Communication RS grams Remote Paging Console Fibre Optic Network Interface for EV3000 The fibre modem network interface kit offers the user a method of interconnecting two (2) or more EV3000 Emergency Warning and Intercom System (EWIS) using fibre optic cable as an alternative to copper. The modems convert hardwired data and audio, to a common fibre optic compatible output. The fibre optic modems are full duplex and have 4-channels to carry both data and two (2) audio signals. Two (2) channels are required emergency public address and warden intercom audio signals. Fibre Optic Network Interface for EV EV Core Single Mode Fibre Network Interface EV300 Single Core Multi Mode Fibre Network Interface EV300 Single Core Singe Mode Fibre Network Interface The WIP is installed remote to the ECP Provides intercommunication between users at the WIP and Emergency Control Panel This feature is only available when the Emergency Warning Intercom facility has been incorporated in the control panel Made of high impact red ABS plastic Compatible with most EV3000 systems manufactured before July 2010 Operating Line Current draw Line Impedance Line Level Cabling Dimensions 27 VDC (line driven) On hook - 25 VDC max Off hook - 14 VDC max On hook - 5 ma max Off hook - 35 ma max 360 ohm balanced 0 db (± 3dB) 3 wire - 2.5mm² max. 215H x 85W x 62D mm 380 grams Warden Intercom Phone 3 Wire WIP Enclosure Metal Surface Mounted

20 38 Graphics Package 39 Smart GraphicsHD AMPAC s SmartGraphicsHD System unleashes the full power of FireFinder (fire detection) and the EV3000 (alarm and intercom) by creating a robust and versatile hub for controlling your fire detection, alarm and intercom systems with one fully integrated package. Flexible and intuitive in its design, SmartGraphicsHD puts the command of your systems at your fingertips. Main Screen Fire Status Indication Interfaces to the FireFinder fire detection panel and the EV3000 emergency warning and intercom system Clearly shows on the building floor plan the start and spread of the fire and the status of the emergency warning and intercom system Has capabilities of ing maps to emergency service organisations and key stakeholders Supports the latest 1920x1080 HD computer technology Able to operate over existing IT infrastructure Can be expanded to incorporate multi-site facilities into one central monitoring package Historic data log on the activity of the fire detection system and alarm system Three level password protection Detailed Egress Pathways Building Information (like hazardous materials) and mustering point displayed on maps Item Numbers Disable and Control SmartGraphics HD License Kit SmartGraphics HD PC System Complete SmartGraphics HD Touch PC System Complete USB-RS232 Converter Kit USB-RS485/422 Converter Kit SmartGraphics 19 Rack PC with Touch Screen Access Map History Page

21 40 Detection & MCP s 41 Series 65 Detection Series 65 Optical Smoke Detector The Series 65 Optical Smoke Detector incorporates a pulsing LED located within the housing of the detector. The external detector moulding is identical to that of the ionisation detector but has an indicator LED which is clear in quiescent state but produces red light in alarm. Responds well to slow-burning, smouldering fires Well suited for bedrooms and escape routes Unaffected by wind or atmospheric pressure Series 65 Optical Smoke Detector Series 65 Ionisation Smoke Detector The Series 65 Ionisation Smoke Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm. Responds well to fast-burning, flaming fires Designed to operate in a variety of environments Series 65 Ionisation Smoke Detector Series 65 Integrating Ionisation Smoke Detector Series 65 incorporates well-proven sensing technologies together with advances in materials and electronics. Developed from the highly successful Series 60 range of detectors, Series 65 includes a chip (integrated circuit) based on that used in XP95 analogue addressable detectors. The range consists of ionisation, integrating ionisation and optical smoke detectors, four grades of heat detector and a range of bases. Wide operating voltage Advanced electronic technology Flashing LED option Magnetic test switch option Can be used on security systems Electrically and mechanically compatible with Series 60 Proven detection performance Optical Ionisation Integrating Ion Heat Operating voltage 9 to 33 V dc 50μA at 24 V dc Alarm current 52mA at 24 V dc Operating temp (no icing) -20 C to +60 C -20 C to +90 C Diameter 100mm Height 50mm inc base 150 grams 15 grams 153 grams 131 grams IP Rating IP23D (EN60529) Approvals AS240-7 AS240-5 Ionisation Detectors use a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm. Circuitry in the Ionisation Smoke Detector protects against transient levels of smoke above the normal threshold for up to 20 seconds. Responds well to fast-burning, flaming fires Designed to operate in environments where transient levels of smoke may be expected Series 65 Integrating Ionisation Smoke Detector Series 65 Heat Detector The Series 65 Heat Detector monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature. There are four classes of heat detectors in the Series 65 range designed to suit a wide variety of operating conditions. Can be used for applications where smoke detectors are unsuitable Ideal in environments that are dirty or smoky under normal conditions Series 65 A1R Standard Rate-of-Rise MAT 50 C, MSRT 65 C Series 65 BR Standard Rate-of-Rise MAT 65 C, MSRT 85 C Series 65 CR Standard Rate-of-Rise MAT 80 C, MSRT 100 C Series 65 CS Standard Static MAT 80 C, MSRT 100 C Series 65 Standard Base The Series 65 Standard Base has been designed to enable detectors to be fitted without the need for force particularly useful when fitting to suspended ceilings. All Series 65 bases have a one way fit and can be locked into place by a grub screw using a 1.5mm hexagonal screwdriver. Detector locking mechanism One way fit Easy to wire Contains an earth connector Contains no electrical parts Series 65 Standard Base

22 42 Detection & MCP s 43 Heat Detection Orbis Detection Type E Detector Type E Detector The Type E Heat Detector is a thermal sensitive switch. It is a fixed temperature device with a factory pre-set temperature in the range 60 C to 240 C. The detectorcomprises a pair of normally open electrical contacts mounted within a stainless steel Probe Resetting Type Heat Detector Rate Compensation & Fast Response Wide Temperature Range Gold Plated Electrical Contacts Corrosion & Shock Resistant Contacts Operating Current Applied DC at 0.25A Operating Temp Set-point Ambient Temp Range Sensitivity & Accuracy Approvals Normally open, close on temp set-point 0.25 A max 32 V max +60 C to +240 C -40 C to +180 C IP grams +/- 5% or degrees AS (CSIRO) Type E Heat Detector Dual Thread Type E Heat Detector Single Thread Thermal Type B Sealed Cool Room Detector (Hoc) The conventional Type B Cool Room Heat Detector is a 60 C fixed temperature waterproof detector. The detector uses a bi-metallic strip to sense temperature change,therefore consuming minimal standby current and providing high reliability. Waterproof Design rated to IP67 No Mounting Base Required Low Current Consumption CSIRO Approved to AS Operating Max Alarm Current Remote LED Current Dimensions Colour Approvals 15 to 30 V dc (Nominal 24 V dc) 50 ma at 24 V dc 4mA at 5V 98 mm Dia x 45 mm H -10 C to +40 C Ivory IP67 80 grams AS Type B Cool Room Heat Detector Orbis is a range of conventional detectors which has been developed with sophisticated technology previously only found in intelligent detectors. Orbis is a range with modern styling and incorporates a mounting base wihich saves installation time. Automatic drift compensation with DirtAlert warning Patented FasTest which reduces the time taken to test detectors SensAlert uses a flashing LED to indicate that the sensor is not operating correctly StartUpTM for fast commissioning Attractive and compact design Electrically compatible with Series 60 and Series 65 Wide voltage and operating temperature ranges Algorithms for transient rejection Flashing LED option 360 visibility of LEDs Insect resistant Operating voltage Alarm current Optical Multisensor Heat 8.5 to 33 V dc 95μA at 24 V dc 40mA at 24 V dc Operating temp -40 C to +70 C (no icing) 0 to 98% (non condensing) Diameter 97mm Height inc base 46mm 57mm 51mm inc base 135 grams 140 grams 130 grams IP Rating IP23D (EN60529) Approvals AS AS7240-5

23 44 Detection & MCP s 45 Orbis Detection Optical Smoke Detector The Orbis Optical Smoke Detector works using the well established light scatter principle, however, the sensing technology is radically different in design from previous optical detectors and significantly reduces false alarms. Responds well to slow-burning, smouldering fires Performs well in black and white smoke Extra confirmation of smoke before alarm signal is given Reduced incidence of false alarms Sensing chamber keeps out dust and other airborne contaminants Operates over a broad range of voltages at extremes of temperature Orbis Optical Smoke Detector Multisensor Smoke Detector The Orbis Multisensor Detector benefits from the same false alarm reduction technology as the optical detector. It is a thermally enhanced smoke detector and so will not give an alarm from heat alone. Responds well to slow-burning, smouldering fires Performs well in black and white smoke Extra confirmation of smoke before alarm signal is given Reduced incidence of false alarms Sensing chamber keeps out dust and other airborne contaminants Operates over a broad range of voltages at extremes of temperature Orbis Multisensor Detector Heat Detector The Orbis Heat Detector monitors temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. There are seven classes of heat detectors in the Orbis range designed to suit a wide variety of operating conditions. Can be used for applications where smoke detectors are unsuitable Ideal in environments that are dirty or smoky under normal conditions Reduced incidence of false alarms Increased reliability of detection Orbis A1R (50 C) Heat Detector Rate of Rise Orbis A2S (50 C) Heat Detector (Type B) Static Orbis BR (65 C) Heat Detector (Type A) Rate of Rise Orbis BS (65 C) Heat Detector Static Orbis CR (80 C) Heat Detector (Type C) Rate of Rise Orbis CS (80 C) Heat Detector (Type D) Static Orbis TimeSaver Relay Base To support the Orbis detectors a range of bases are available. Each base has two slots for fixing screws at a spacing of 51mm to 69mm. The detectors fit into the base one way only and require minimal force in a clockwise rotation. The TimeSaver Relay base incorporates a single pole voltage-free changeover contact for switching external equipment. The relay is energised when the detector changes to alarm state and deactivates when the detector is reset. The relay is capable of switching up to 30V at 1A. The Orbis Adaptor base enables the detector to be fitted to a Series 60/65 base. Orbis LX Base Orbis TimeSaver Relay Base Orbis Adaptor Base Manual Call Points Manual Call Point ACP-04 Double terminal, wire protected connectors for independent input and output connections when looping to other devices Protective film prevents glass from splintering when broken Current Rating 12/24 VDC 48 VDC Size 88mm H x 88mm W x 59mm D (surface) 88mm H x 88mm W x 27mm D (flush) Switch Type Single pole micro Cable termination 6 x 2.5mm2 screw In-Line Resistor 470Ω (N/O operation only) Material High impact ABS Operating Temperature -5 C to +70 C Humidity 0 95% non-condensing IP 24D (indoor use) 153 grams Manual Call Point ACP-04 Red Manual Call Point ACP-04 Yellow Manual Call Point ACP-04 White Manual Call Point ACP-04 Green Manual Call Point ACP-04 Protective Cover Manual Call Point ACP-04 Glass Manual Call Point Conventional Weatherproof The Weatherproof Manual Call Point has been designed for use outdoors and in places where moisture may be present. The Manual Call Point provides a simple single pole changeover contact for use with older fire systems or in other applications requiring switching at up to mains voltage. Contact rating Size Switch type Material Temperature range 3A at 24 VDC 87mm H x 87mm W x 57mm D Single Pole High Impact ABS -25 C to +70 C IP65 220g IP65 MCP Reset n/c n/o con Manual Call Point - Conventional Waterproof The Conventional Waterproof Manual Call Point has been designed to work on conventional systems. The Manual Call Point has an easilt resettalbe element rather than a break glass. Supply 9-33VDC Operatin Temperature -30 o to 70 o Humidity 0-95% (No condensation or icing) IP Rating 67 Alarm Resistance Ohms Current (Alarm LED On) 80mA Conventional Waterproof MCP

24 46 Detection & MCP s 47 Sampling Duct Units Beam Detection The FIRERAY 5000 motorised reflective, auto aligning infrared optical beam smoke detector can be installed with up to two detector heads per system, thus saving on installation time and costs. In addition, each system controller houses two pairs of fire and fault relays, one per detector. This innovative system has been designed from the ground up to include pioneering technology that fully addresses the needs of the installer and user, both now and in the future. The Ampac Duct Sampling Unit is designed to monitor levels of smoke in air ducts operating in air speeds of 0.5 to 20 meters per second. The duct smoke detector can be fitted to any wall of a ventilation duct and has two tubes that extend into the duct through punched holes. The perforated sampling tube is placed in the airflow upstream of the exhaust tube which causes a pressure differential in the duct detector. Air is sucked up the sampling tube, across the detector and exhausted back into the air duct. Using the 360mm sampling pipe supplied, an air duct of up to 560mm can be monitored. For duct widths greater than 560mm, three other lengths of sampling pipe are available. Both sampling and exhaust pipes are fitted to the back box without the need for tools making installation easier The cover of the duct smoke detector is monitored to ensure working integrity and if removed, causes a fault to appear at the fire alarm control panel Easily accessible wire clamping terminals ensure secure and fast termination Clear cover hence the alarm LED on the detector is visible at all times Integral smoke test port Sampling pipes available in 4 lengths Operates in air speeds of 0.5 m/s to 20 m/s Volt free contacts Item Numbers Allows for 2 Detectors per System Controller Each Detector configurable from 8m to 100m Separate Fire and Fault relays per Detector Integral LASER alignment Auto-Align Fast Automatic Beam Alignment Building Movement and Contamination Compensation Low Level System Controller Logs the 50 most recent events per detector Programmable Sensitivity and Fire Thresholds 20mm Cable Gland Knockouts on System Controller 2-wire interface from System Controller to Detector Operating distance (separation) Cable length system controller to detector Operating voltage (to system controller) Operating current with 1 detector Operating current with 2 detectors Item Numbers metres 100 metres 14VDC to 36VDC 5 to 6 ma 7.5 to 8.5 ma -10 C to +55 C (no icing) 93% (non condensing) IP54 Orbis Duct Sampling Unit inc Detector Base Duct Probe 300mm to 750mm Duct Probe 750mm to 1500mm Duct Probe 1500mm to 3000mm Reflective Beam System Reflective Prism Detector & Reflective Prism Long Range Reflective Prism Universal Bracket for Detector Prism Plate (1) Prism Plate (4) Ceiling Pendant Mounting Detector Protective Cage

25 48 Detection & MCP s 49 XP95 Detection XP95 Optical Smoke Detector The XP95 Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely. Responds well to slow-burning, smouldering fires Well suited for bedrooms and escape routes Unaffected by wind or atmospheric pressure XP95 Optical Smoke Detector XP95 Optical (Black) Smoke XP95 Ionisation Smoke Detector The XP95 Ionisation Smoke Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm. Responds well to fast-burning, flaming fires Designed to operate in a variety of environments Minimal effects from temperature, humidity, atmospheric pressure Well protected against electromagnetic interference over a wide frequency range XP95 Ionisation Smoke Detector XP95 Ionisation (Black) The XP95 range of intelligent fire detectors is advanced in design, improved in performance and has unique features that benefit the installer and end user. The range features smoke detectors (ionisation and optical), standard and high temperature heat detectors and a multisensor. Beam detectors, flame detectors, manual call points, audio visual signalling devices, interface units and isolators complete the range. XP95 has a central intelligence system where all the decisions are made by the control panel. Alarm Flag for fast alarm reporting Alarm Address for fast location of alarm XPERT card addressing Electronics-free base Easy installation Elegant design Insect Resistant Operating voltage Optical Ionisation Heat High Heat Multisensor 17 to 28 V dc at 24 V dc 340μA 280μA 250μA 500μA Alarm current at 24 V dc 4mA 2mA 2mA 3.5mA Operating temp (no icing) -20 C to +60 C -20 C to +70 C -20 C to +70 C -20 C to +120 C -20 C to +60 C Diameter 100mm Height 50mm 58mm inc base 157 grams 161 grams 161 grams 150 grams 160 grams IP Rating IP23D (EN60529) Approvals AS XP95 Heat Detector The XP95 Heat Detector monitors temperature by using a single thermistor network which provides a count output proportional to the external air temperature. The XP95 range features two Heat Detectors, standard and high temperature. The standard heat detector is classified as an A2S device and will report an alarm at 55 C. The high temperature detector, classified as a CS device, will report an alarm at 90 C. Ideal in environments that are dirty or smoky under normal conditions Well suited for warehouses, loading bays and car parks Unaffected by wind or atmospheric pressure XP95 Heat Detector Standard A2S XP95 Heat A2S (Black) Detector XP95 Multisensor Detector The XP95 Multisensor Detector contains an optical smoke sensor and a thermistor temperature sensor whose outputs are combined to give the final analogue value. Sensitive to a wide range of fires Well suited for environments such as hotel bedrooms Unaffected by wind or atmospheric pressure XP95 Multisensor Detector

26 50 Detection & MCP s 51 Discovery Detection Discovery Optical Smoke Detector The Discovery Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely. Responds well to slow-burning, smouldering fires Well suited for bedrooms and escape routes Unaffected by wind or atmospheric pressure Remote test feature Discovery Optical Smoke Detector Discovery Multisensor Detector The Discovery Multisensor Detector comprises optical smoke and thermistor temperature sensors whose respective outputs can be split to deliver specific smoke or thermal actions respectively. This capability can aid early Alarm warning routines and other advanced detection techniques. Discovery Multisensor Detector Discovery Multisensor (Black) Discovery Ionisation Smoke Detector Discovery is a range of high-specification, intelligent fire detectors developed to meet the requirements of sophisticated systems while providing engineers with an additional dimension in fire protection capability. Discovery has a distributed intelligence system where decisions are made in the detector head as well as at the control panel. Drift compensation is also incorporated into the detector, allowing it to adapt to dirty or dusty environments reducing false alarms. Rejection of transient signals Flashing LED option Five response modes for ease of optimisation to changing environments Drift compensation to ensure constant sensitivity Four bytes of non-volatile memory for user data Alarm flag for fast alarm reporting Conventional alarm facility during control panel processor fault 360 visibility in alarm Compatible with XP95 systems Insect resistant Optical Optical/Heat Multisensor Ionisation CO/Heat Multisensor Carbon Monoxide Operating voltage 17 to 28 V dc 24 V dc 300μA 400μA 300μA 400μA 300μA Alarm current 24 V dc 3.5mA Operating temp (no icing) -40 C to +70 C -30 C to +70 C -20 C to +55 C Diameter 100mm Height inc base 50mm 58mm 50mm 60mm 50mm inc base 160 grams IP Rating IP44 (EN60529) Approvals AS AS AS The Discovery Ionisation Smoke Detector uses a low activity radioactive foil to irradiate the air in the smoke chamber causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm. Responds well to fast-burning, flaming fires Designed to operate in a variety of environments Remote test feature Discovery Ionisation Smoke Detector Discovery Heat Detector The Discovery Heat Detector, distinguishable by the low airflow resistant case, uses a single thermistor to sense the air temperature around the detector. Ideal in environments that are dirty or smokey under normal conditions Well suited for warehouses, loading bays and car parks Unaffected by wind or atmospheric pressure Remote test feature Discovery Heat Detector Discovery CO/Heat Multisensor Detector The Discovery CO/Heat Multisensor Detector is good at detecting deepseated smouldering fires which give off a lot of CO as well as flaming fires. They are ideal for use in hotel bedrooms where steam may be present, dusty environments or even where simulated smoke may be present. Enhanced detection capability Early response to hot fires Ideal for smouldering fires Less susceptible to false alarms caused by steam than smoke alarms Five response modes Discovery CO/Heat Multisensor Detector

27 52 Detection & MCP s 53 Discovery Detection Discovery Carbon Monoxide Detector The Discovery Carbon Monoxide (CO) Detector is good at detecting deep-seated fires. Please note that CO detectors do not detect smoke particles or heat and are not universal replacements for smoke detectors. Enhanced detection capability Early response to hot fires Ideal for smouldering fires Less susceptible to false alarms caused by steam than smoke alarms Five response modes Discovery Carbon Monoxide Detector XP95/Discovery Intelligent Detector Base All detectors in the XP95 range fit the Intelligent Detector Base. It is a low insertion force base with stainless steel contacts for the detector terminals. XPERT addressing One way fit of detector Locking feature to prevent unauthorised removal XP95/Discovery Detector Base XP95/Discovery Detector Base (Black) XP95/Discovery Isolating Base The new style Isolating Base senses and detects short-circuit faults on XP95 loops and spurs. Up to 20 devices may be installed between isolating bases High brightness LED XP95/Discovery Isolating Base XP95/Discovery Intelligent Low Power Relay Base The Low Power Relay Base incorporates a low power relay to control field equipment such as automatic door closers. Gives a set of voltage free contacts controlled by the remote output of a detector Draws negligible current Capable of switching up to 30V at 1A XP95/Discovery Low Power Relay Manual Call Points Intelligent Manual Call Point (New) The Intelligent Manual Call Point has a highly visible alarm indicator which can be seen from up to 10 metres away. When activated, the manual call point interrupts the polling cycle for a fast response. A combined LED indicator and front reset mechanism allows for a quick and simple reset VDC 100μA Alarm current 4mA Dimensions (surface mount) 87H x 87W x 54D mm -40 C to +70 C Humidity 0-95% RH grams Inetlligent Manual Call Point with Isolator Transparent Cover Pack of 10 Reset Keys Waterproof Manual Call Point (New) The Waterproof Addressable Manual Call Point has a highly visible alarm indicator which can be seen from up to 10 metres away. When activated, the manual call point interrupts the polling cycle for a fast response and has a combined LED indicator and front reset mechanism allowing for a quick and simple reset. Alarm current Size (surface mount) VDC 100μA 4mA 110H x 110W x 74D mm -30 C to +70 C 0-95% RH IP grams Waterproof Manual Call Point Transparent Cover Pack of 10 Reset Keys Addressable XP95 Manual Call Point The XP95 Manual Call Point has been designed to operate on a loop of intelligent addressable fire detection devices. The address of each call point is set at the commissioning stage by means of a seven segment DIL switch. The device features plug and play terminal connections and a resettable element. Alarm current Address method Size (surface mount) VDC 100μA at 24VDC 4mA 7 segment DIL switch 93mm H x 89mm W x 59.5mm D -20 C to +60 C (no icing) 0-95% (non condensing) IP24D (indoor use) 160 grams XP95 Manual Call Point (Surface) XP95 Manual Call Point Protective Cover Intelligent Waterproof Manual Call Point

28 54 Detection & MCP s 55 Duct Sampling Unit Flame Detection The Ampac Duct Sampling Unit is designed to monitor levels of smoke in air ducts operating in air speeds of 0.5 to 20 meters per second. The duct smoke detector can be fitted to any wall of a ventilation duct and has two tubes that extend into the duct through punched holes. The perforated sampling tube is placed in the airflow upstream of the exhaust tube which causes a pressure differential in the duct detector. Air is sucked up the sampling tube, across the detector and exhausted back into the air duct. Using the 360mm sampling pipe supplied, an air duct of up to 560mm can be monitored. For duct widths greater than 560mm, three other lengths of sampling pipe are available. Both sampling and exhaust pipes are fitted to the back box without the need for tools making installation easier The cover of the duct smoke detector is monitored to ensure working integrity and if removed, causes a fault to appear at the fire alarm control panel Easily accessible wire clamping terminals ensure secure and fast termination Clear cover hence the alarm LED on the detector is visible at all times Integral smoke test port Sampling pipes available in 4 lengths Operates in air speeds of 0.5 m/s to 20 m/s Volt free contacts Item Numbers Duct Sampling Unit inc XP95 Detector Base Duct Probe 300mm to 750mm Duct Probe 750mm to 1500mm Duct Probe 1500mm to 3000mm Flame detectors are effective in protecting areas where flaming fires may be expected. There is a choice of detection techniques - Ultra Violet and Infra-red, or a combination of both. UV Flame Detectors are generally used in engine rooms, factories and warehouse applications. Infra-red Flame Detectors are able to tolerate dirtier environments which may block UV radiation and are generally used in applications such as waste handling, colour printing and paper manufacturing. Detects a wide range of open fires Insensitive to wind Transient voltage protection Three types of detector Lockable security fitting White finish UV Base IR2 Base IR3 Base IR2 Flame IR3 Flame Operating voltage V DC at 24 V dc 2.3mA 2.8mA 2.2mA 2.2mA 2.2mA Field of view 90 cone 90 cone 90 cone Operating temp (no icing) -40 C to +55 C -10 C to +55 C Dimensions 100D x 48H mm 142W x 108H x 82D mm 210g 1 kg 2 kg IP Rating IP66 IP65

29 56 Detection & MCP s 57 Flame Detection Intelligent Base Mounted UV Flame Detector The Intelligent Base Mounted UV Flame Detector is designed to protect internal areas where open fires may be expected. The detector has a single UV sensor with a narrow spectral response in order to discriminate between flames and most spurious sources of radiation. Responds to stationary flames with no flicker Sensitive to UV radiation emitted by flames during combustion Compact flame detector which can fit into Discovery or XP95 bases Loop-powered Increased reliability of detection XP95 Base Mounted UV Flame Detector Intelligent Dual IR Flame Detector The Intelligent Dual Infra-Red (IR²) Flame Detector is designed for use in areas where flaming fires may be expected. The detector has two sensors which respond to different IR wavelengths to discriminate between flames and spurious sources of radiation. Applications include aircraft hangars, coal handling and paper manufacturing plants and woodworking environments. XP95 Dual IR2 Flame Detector Intelligent Triple IR Flame Detector The Intelligent Triple IR Flame Detector (IR³) is designed to protect areas where open flaming fires may be expected. It is sensitive to low frequency, flickering infra-red radiation emitted by flames during combustion. XP95 Triple IR3 Flame Intelligent Base Mounted UV IR² Flame Detector The Intelligent Base Mounted UV IR² Flame Detector is designed to protect areas where open flaming fires may be expected. The detector has a UV and dual IR sensors responding to different wavelengths in order to discriminate between flames and spurious sources of radiation. Responds to stationary flames with no flicker Sensitive to UV and low-frequency flickering IR radiation emitted by flames during combustion Compact flame detector which can fit into Discovery or XP95 bases Loop-powered False alarms due to electrical discharges from lightning or arc welding and flickering sunlight are minimised Base Mounted Flame Detector Bracket The Flame Detector Bracket is an optional accessory for the Intelligent Flame Detectors. It is a stainless steel mounting bracket adjustable in two axis. Bracket for Base Mounted Flame Detectors XP95 Base Mounted UV IR² Flame Detector Flame Detector Bracket The Flame Detector Bracket is an optional accessory for the Intelligent Flame Detectors. It is a stainless steel mounting bracket adjustable in two axis. Not suitable for Base Mounted Flame Detectors. Intelligent Base Mounted IR³ Flame Detector The Intelligent Base Mounted IR³ Flame Detector is designed to protect areas where open flaming fires may be expected. The detector has three IR sensors that respond to different IR wavelengths in order to discriminate between flames and spurious sources of radiation. Responds to stationary flames with no flicker. Sensitive to low-frequency flickering IR radiation emitted by flames during combustion. Compact flame detector which can fit into Discovery or XP95 bases. Loop-powered. False alarms due to factors such as flickering sunlight are avoided by a combination of filters and signal processing techniques. Flame Detector Bracket Flame Detector Weather Shield The Flame Detector Weather Shield protects the device from inclement conditions. S/Steel Weather Shield for Standard Flame Detector XP95 Flameproof IR³ Flame Detector

30 58 Detection & MCP s 59 Hazardous Area Detection TM Orbis I.S. Optical Smoke Detector The Orbis I.S. Optical Smoke Detector works using the light scatter principle, and is ideal for applications where slow burning or smouldering fires are likely. Reduces false alarms Recommended for early warning of fire in most areas Improved sensitivity to black smoke Compensation for slow changes in sensitivity Algorithms for reliability of alarm Orbis I.S. Optical Smoke Detector Orbis I.S. Multisensor Detector The Orbis I.S. Multisensor Detector benefits from the same false alarm reduction technology as the optical detector. It is a thermally enhanced smoke detector and so will not give an alarm from heat alone. Reduces false alarms Sensitive to fast burning, flaming fires Improved sensitivity to black smoke Compensation for slow changes in sensitivity Algorithms for reliability of alarm Orbis I.S. Multisensor Detector Orbis I.S. Heat Detector Ampac offers a range of Intrinsically Safe detectors in both conventional and addressable. Orbis IS ia a range with modern styling and is electronically compatible with Apollo Series 60 intrinsically safe conventional detectors. XP95 Intrinsically Safe range is a development of the well established intelligent XP95 range from Apollo specifically for use in hazardous areas and are set by means of the patented XPERT card. Operating voltage Optical Ionisation Heat 14 to 22 V dc 24 V dc 340μA 300μA 300μA Operating temp range Dimensions inc base 20 C to +60 C (no icing) 100Dia x 50H mm inc base 157 grams 161 grams 161 grams IP Rating Category IP23D (EN60529) II IG Ex ia IIC T5-20 C Ta 45 C (T4 60 C) Ga Certificate IECEx BAS X, BAS02ATEX 1289 The Orbis IS Heat Detector monitors temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. There are seven classes of heat detectors in the Orbis IS range designed to suit a wide variety of operating conditions. Can be used for applications where smoke detectors are unsuitable Ideal in environments that are dirty or smoky under normal conditions Reduced incidences of false alarms Increased reliability of detection Orbis I.S. A1R Heat Detector- Rate of Rise Orbis I.S. A1S Heat Detector- Static Orbis I.S. A2S Heat Detector- Static Orbis I.S. BR Heat Detector- Rate of Rise Orbis I.S. BS Heat Detector- Static Orbis I.S. CR Heat Detector- Rate of Rise Orbis I.S. CS Heat Detector- Static Orbis I.S. TimeSaver Base The Orbis IS TimeSaver Base is a completely new design that provides installers with an open working area with fixing holes shaped to allow a simple mounting procedure. Grouped terminals to make wiring easy Two fixing centres LED alignment mark Detector locking mechanism Orbis I.S. TimeSaver Base

31 60 Detection & MCP s 61 Hazardous Area Detection XP95 I.S. Ionisation Smoke Detector The XP95 I.S. Ionisation Smoke Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm. Detects super heating and flaming combustibles Dual chamber technology Wind resistant smoke inlets. Transient voltage protection Fine gauze insect protection Lockable security fitting Must be connected to a suitable safety barrier and protocol translator XP95 I.S. Ionisation Smoke Detector XP95 I.S. Optical Smoke Detector The XP95 I.S. Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely. Detects a wide range of fires Insensitive to wind Transient voltage protection Fine gauze insect protection Simple construction allows detection chamber to be cleaned Lockable security fitting Must be connected to a suitable safety barrier and protocol translator XP95 I.S. Optical Smoke Detector XP95 I.S. Heat Detector The XP95 I.S. Heat Detector operates by measuring heat levels with a single thermistor network which gives a count output proportional to the external air temperature. Rate of rise and fixed temperature alarm point Single thermistor technology Transient voltage protection Resettable operation Lockable security fitting Must be connected to a suitable safety barrier and protocol translator XP95 I.S. Heat Detector XP95 I.S. Mounting Base The XP95 I.S. Mounting Base has been designed to accept only IS products. This ensures that standard detectors cannot inadvertently be fitted into an intrinsically safe system. XPERT cards are supplied with all bases. Wide cable entry Contains no electronic parts One way only fit Low insertion force Large terminations Lockable security fitting White finish. Must be connected to a suitable safety barrier and protocol translator Conventional Galvanic Barrier The Conventional Galvanic Barrier is installed in the safe area and ensures system integrity Orbis I.S. Galvanic Barrier Singel Channel Orbis I.S. Galvanic Barrier Dual Channel Conventional Indoor I.S. MCP Red (470 ohm) The conventional IS manuall call point has been designed to aperate on contenctional instrinsically safe fire detection systems. designed specifically for use in atmospheres which explosivemixures are or may be present. Supply Dimensions Material Conventional Intrinsically Safe Call Points The range of conventional manual call points include break glass, push button and tool reset versions which are approved for Zone 0, 1, 2, 21 and 22 requiring intrinsically safe equipment for the control of fire and gas alarm systems Supply Dimensions Material Aluminium IP Rating Approvals 30V DC 93mm H x 89mm W x 59.5mm D ABS Conventional Indoor I.S. MCP Red (470 ohm) V DC (28 max) 98mm H x 95mm W x 76mm D Marine grade copper free LM6 IP66 ATEX, IECEx, Inmetro, GOST-R IS Break Glass Call Point, Red IS Push Button Call Point, Red IS Tool Reset Call Point, Red I.S. Break Glass Call Point I.S. Push Button Call Point I.S. Tool Reset Call Point XP95 I.S. Mounting Base

32 62 Detection & MCP s 63 Hazardous Area Detection IP65 I.S. Manual Call Points The XP95 IS Manual Call Point is based on the standard weatherproof model. It features an interrupt facility to provide fast response to an alarm. 14 to 22 VDC 300uA Alarm current 2mA (alarm LED On) Size 124mm H x 124mm W x 60mm D 20 C to +40 C (T5) 20 C to +60 C (T4) Humidity 0 to 95% IP grams Classification E Ex ia IIc T5 Approvals EN54-11 XP95 Intrinsically Safe Manual Call Point XP95 I.S. Protocol Translator and Galvanic Barrier The Protocol Translator and Galvanic Barrier are installed in the safe area ensuring integrity of communication between control equipment and field devices and safety within the limits of BASEEFA approvals Enables IS detectors to be connected to a standard loop driver Loop powered DIN-Rail mounting Maximum of 20 XP95 IS devices per channel Translators must be connected to detectors via a suitable safety barrier XP95 Protocol Translator Single Channel XP95 Protocol Translator Dual Channel XP95 I.S. Galvanic Barrier Conventional BEx Flameproof Call Points The range of conventional manual call points include break glass, push button and tool reset versions which are approved for Zone 1, 2, 21 and 22 hazardous areas for the control of fire and gas alarm systems. Supply Dimensions Material Aluminium Colour Operating Temperature IP Rating Approvals Intelligent Flameproof Triple IR Flame Detector 24V DC (28 max) 98mm H x 95mm W x 76mm D Marine grade copper free LM6 Red (RAL3000) Ta = -40 C to +50 C IP66 800g ATEX, IECEx, GOST-R BEx Break Glass Call Point, Red, 470R Fire, 3K3 EOL BEx Push Button Call Point, Red, 470R Fire, 3K3 EOL BEx Tool Reset Call Point, Red,470R Fire, 3K3 EOL BEx Break Glass Call Point, Red, 470R Fire BEx Push Button Call Point, Red, 470R Fire BEx Tool Reset Call Point, Red, 470R Fire BEx Push Button Call Point, Yellow, 470R Fire, 3K3 EOL The Intelligent Triple IR Flame Detector (IR³) is designed to protect areas where open flaming fires may be expected. It is sensitive to low frequency, flickering infra-red radiation emitted by flames during combustion. Loop-powered Sensitive to flickering IR radiation Detects through films of oil, dust, water and ice Responds to flickering flames, including those invisible to the naked eye False alarms due to lighting or flickering sunlight are minimised Compatible with Discovery and XP95 protocols XP95 Flameproof IR³ Flame Detector DIN-Rail Interface Enclosures DIN-Rail Interface Enclosures are available and can be used for housing intrinsically safe (IS) barriers or DIN-Rail mounted interfaces. A multi-purpose label that features a section for use with IS systems is supplied. For non-is systems, the part referring to IS can simply be removed. XP95 IS DIN Rail Interface Enclosure (4 units) I.S. DIN Rail Interface (10 Units) Intelligent Flameproof Dual IR Flame Detector The Intelligent Dual Infra-Red (IR²) Flame Detector is designed for use in areas where flaming fires may be expected. The detector has two sensors which respond to different IR wavelengths to discriminate between flames and spurious sources of radiation. Applications include aircraft hangars, coal handling and paper manufacturing plants and woodworking environments. Sensitive to flickering IR radiation Detects through films of oil, dust, water and ice Responds to flickering flames, including those invisible to the naked eye Compatible with Discovery and XP95 protocols Remote optical self-test function 90 field of view Up to 40m coverage XP95 Flameproof IR² Flame Detector

33 64 Audio Detection Visual & MCP s & Interafaces 65 Marine Detection TM Orbis Marine Optical Smoke Detector The Orbis Marine Optical Smoke Detector works on the well established light scatter principle. However, the sensing technology is radically different in design from previous optical detectors and significantly reduces false alarms. Orbis Marine Optical Smoke Detector Orbis Marine Multisensor Detector The Orbis Marine Multisensor Detector benefits from the same false alarm reduction technology as the optical detector. It is a thermally enhanced smoke detector and so will not give an alarm from heat alone. Orbis Marine Multisensor Detector Orbis Marine Heat Detector The Orbis Marine Heat Detector uses a single thermistor to sense the air temperature around the detector. There are six classes of heat detectors in the Orbis Marine range designed to suit a wide variety of operating conditions. Orbis Marine A1R Heat Detector- Rate of Rise Orbis Marine A2S Heat Detector- Static Orbis Marine BR Heat Detector- Rate of Rise Orbis Marine BS Heat Detector- Static Orbis Marine CR Heat Detector- Rate of Rise Orbis Marine CS Heat Detector- Static Orbis Marine TimeSaver Base The Orbis Marine TimeSaver Base is a completely new design that provides installers with an open working area with fixing holes shaped to allow a simple mounting procedure. Orbis Marine TimeSaver Base

34 66 Detection & MCP s 67 Xpander Wireless Detection XPander Heat Detector and Mounting Base There are two heat detectors in the Xpander range designed to suit a wide variety of operating conditions. A static heat detector (CS) which responds only when a fixed temperature has been reached and a rate-of-rise detector (A1R) which has a fixed upper limit, but in addition, measures the rate of increase in temperature (regulated from radio base) Size inc base inc base 3VDC 105mm D x 80mm H -10 C to +50 C (no icing) IP23D 400 grams XPander A1R Heat Detector and Mounting Base XPander CS Heat Detector and Mounting Base XPander Optical Smoke Detector and Mounting Base The Xpander Optical Smoke Detector works on the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely. Size inc base inc base 3VDC 100mm D x 75mm H -10 C to +50 C (no icing) IP23D 500 grams XPander Optical Smoke Detector and Mounting Base Xpander Combined Sounder & Detector The Xpander Combined Sounder and Detector is wireless and designed to proved one point notification and detection. Traditionally, fire detection systems in industrial and commercial applications have used hard wired installations. These systems are generally installed at the time of construction or refurbishment, making the laying of cables not a great issue. However, certain applications do not lend themselves to this approach, such as occupied buildings, heritage sites, architecturally sensitive buildings and annexes. This is where wireless systems provide the ideal solution. Xpander is a system in which individual detectors, call points and alarm devices communicate with the XP95 loop by radio signals. Easy to install. XPERT card addressing. Self-monitoring. Proven technology. 915MHz radio channels. Up to 31 devices per interface. Up to 5 interfaces per loop (max devices per loop 126 inc interface) All detectors within the Xpander range are supplied complete with mounting bases. Wireless Avaliable with a choice of Xpander detectors Bi-directional (monitored) radio platform A choice of 4 Tones including Temporal T3 XPander Sounder Heat A1R Combined Detector & Base XPander Sounder Heat CS Combined Detector & Base XPander Sounder Optical Combined Detector & Base Xpander Combined Sounder Visual Indicator and Detector The Xpander Combined Sounder Visual Indicator and Detector is wireless and designed to privide a one point notification and detection. Wireless Avaliable with a choice of Xpander detectors Bi-directional (monitored) radio platform A choice of 4 tone including Temporal T3 XPander Sndr VI Red Heat A1R Combined Detector & Base XPander Sndr VI Red Heat CS Combined Detector & Base XPander Sndr VI Red Optical Combined Detector & Base XPander Sndr VI Clear Heat A1R Combined Detector & Base XPander Sndr VI Clear Heat CS Combined Detector & Base XPander Sndr VI Clear Optical Combined Detector & Base

35 68 Detection & MCP s 69 Xpander Wireless Detection XPander Sounder Red and Red Mounting Base The Xpander Sounder and Sounder Base is wireless and designed to be used with Xpander detectors and manual call points. Alarm tones (selectable) Sound output 3VDC includes Temporal T3 IP21C 100dB(A) XPander Sounder Red and Red Mounting Base XPander Sounder White and White Mounting Base XPander Sounder Beacon The Xpander Sounder Beacon and Sounder Base is wireless and designed to be used with Xpander detectors and manual call points. Alarm tones (selectable) Sound output 3VDC includes Temporal T3 IP21C 100dB(A) XPander Sounder Beacon Red and Red Mounting Base XPander Sounder Beacon Amber and White Mounting Base XPander Sounder Beacon Clear and White Mounting Base Xpander Hub & Cluster The Xpander Hub and Cluster System comprises of Radio Hub capable of receiving information from a maximum of 31 Radio Cluster Communicators (RCCs). The RCCs are each capable of receiving information from up to 31 wireless detection and alarm devices from the Xpander range. Operating Temperature Humidity Operating Power Requirements Radio Hub RCC Battery Backup: Radio Hub RCC Battery Standby Time: Radio Hub RCC Material: Dimensions and of Interface -10 C to 50 C (ambient) Up to 95% non-condensing 17 to 28V DC 40mA at 24V DC Mains Powered VAC, 50Hz N/A 1 x 6V 4Ah N/A 72 Hours ABS - IP54 270mm width x 205mm height x 85mm depth, 950 grams Xpander Radio Hub Xpander Radio Communications Cluster Xpander Manual Call Point The Xpander Manual Call Point is compliant with AS and is powered by two independent packs of three AA alkaline batteries with a typical five year life. Size inc base inc base Regulated 3V from radio circuiting 105mm D x 80mm H -10 C to +50 C (no icing) IP23D 500 grams XPander Manual Call Point Transparent Hinged Cover for Manual Call Point Xpander Diversity Loop Interface Unit The Xpander Diversity Loop Interface Unit is connected to the detection loop and provides bi-directional communications from the LoopSense and FireFinder control panels to the wireless devices. Operating Current Mechanical Isolation Material Dimension Humidity 24VDC + voltage pulses 15mA Isolator included as standard ABS 270mmW x 205mmH x 85mmD -10 C to +55 C 0% to 95% relative humidity (no condensation) XPander Diversity Interface Module with Isolator Xpander Input/Output Unit The Xpander Input/Output Unit is a radio based interface and offers two monitored input circuts and two relay outputs. It can be used for controlling fire doors, fire dampers, smoke vents and other fire engineering applications. Supply 3VDC + Relay Rating 2A at 30VDC Material ABS grey plastic Dimensions 120mm W x 240mmH x 60mm D Operating Temperature -10 C to +55 C Humidity 0% to 95% relative humidity (no condensation) 65 XPander Input/Output Unit XPander Dual Input/Output Unit Site Survey Kit The Xpander Survey Tool is used at the site survey stage to ascertain if a site is suitable for an Xpander installation. A site survey must be carried out before Xpander can be installed. Indicates the suitability of proposed device location. Tests for radio signal strength. XPander Site Survey Kit Power Supply for Site Survey Kit ( )

36 70 Detection & MCP s 71 Aspirating Smoke Detection -Wagner Titanus Family TITANUS PRO SENS is a universal air sampling device suitable for a broad range of applications. The high degree of modularity of the device makes it possible to achieve a cost-effective solution customised to suit the specific needs of the customer. An additional price advantage comes with the optional equipping of the device with a second detector module. The base TITANUS PRO SENS unit with 2 detector heads fitted (TITANUS PRO SENS 2) can be used for separate zone detection of a room and its equipment, or configured as a double knock tripping system. Each detector is completely separate, with no switching or leak between detection zones Robust & Efficient High Pressure Light Source (HPLS) Detection Technology LOGIC SENS Fire Pattern Recognition Technology Freezer Version Operates in -40Deg to +60DegC with No Heater Boxes Required A Powerful & Efficient Aspirator Allowing up to 560m of Pipework A BlowFree System for Programmed or Automated On-Demand Pipe Clearing Modular Plug In Detector Heads for a Customised & Cost Effective Solution & Maintenance Dual Detector Ability Allows Separate Monitoring & Reporting of Room & Equipment with One Unit Time Saving Installation & Commissioning Via Plug & Play Setup Large Capacity 3-Stage Filters with Selectable 1-15 Micron Ratings A Large Range of Fittings, Pipework and Sampling Points XP95 Interfacing to FireFinderTM and LoopSenseTM Fire Control Panels FIP Bar Graph Display Module Available & SmartGraphicsHD Display Integration Cost Effective Solutions for Every Application Type Specifications Power Supply Detector Unit : PRO SENS PRO SENS 2 Number of Sensor Modules Fitted : 1 2 Max. Number of Sampling Holes : Max. Total Pipe Length Capable : 300m* 560m* : 1460g 1560g Current Start Up Maximum: 300mA 320mA Current - Quiescent (at 24 VDC) 200mA 220mA Current - Alarm (at 24 VDC) 210mA 240mA Operating : 24 VDC (14-30 VDC) Tapered Pipe Connectors: 1 x 25mm 2 x 25mm Detector Dimensions (W x H x D) : 200 x 292 x 113mm Housing Colour: RAL 9018, Papyrus White Cabinet Type, Rating : ABS Plastics IP20 (Optional IP52) Temperature-Standard Version: -20 C to + 60 C Temperature-DeepFreeze Version: -40 C to + 60 C Humidity (Permanent) 10-95% Rel. Non-Condensing Cable Entries: 5 x M20, 2 x M25 Sensor Head Sensitivities: 0.5%, 0.1% and 0.015% Interface Types XP95 Addressable Loop, Conventional Circuit, Relays Alarms 4 Adjustable Threshold Levels: - Alert, PreAlarm, Alarm & Alarm2 Fault Signals Air Flow Low, Air Flow High, Processor/Hardware Fail, Ventilator Fail Air Stabilising Alarm & Fault Relay (CLI Version) Front Panel Control & Indications: 1A, 30 VDC max. Collective Fault - Yellow Operation Green APID & CLI Versions: Reset & Isolate Controls Detector Isolation Yellow X 2 Noise level Standard & Freezer - 45 db(a), Silent Version - 23dB(A) Remote BarGraph Display: Panel Mounted Display Module *The maximum permissible length is pipe branch shape dependant. Item Numbers ProSens Base Unit-APID ProSens Base Unit-CLI ProSens Base Unit- OEM ProSens- 40 Base Unit- APID ProSens-40 Base Unit- CLI ProSens-40 Base Unit- OEM ProSens Detector 0.5% AD ProSens Detector 0.1% AD ProSens Detector 0.015% AD ProSens -40 Detector 0.5% AD ProSens -40 Detector 0.1% AD ProSens -40 Detector 0.015% AD Wagner Filter Box LF-AD AD Wagner Filter Element LF-AD-E AD Wagner Filter Box LF-AD-1 AD Wagner Filter Element LF-AD-ES AD Wagner Filter Box LF-AD-2 AD Wagner Filter Element LF-AD-E2 M AD *Wagner Filter Pipe SF-400 Short AD *Wagner Filter Element SF-400 AD *Wagner Filter Pipe SF-650 Long AD *Wagner Filter Element SF-650 AD Bar Graph Display - Titanus (panel kit) Bar Graph Display - Titanus (add on kit) Remote Bar Graph Display cw Enclosure *Allows full flow right up until 100% Capacity. Special order only.

37 72 Detection & MCP s 73 High Sensitivity Detection System Aspirating Smoke Detection - FastSense FastSense is an aspirating system that adopts laser technology making it extremely sensitive, thus providing the earliest warning to the slightest traces of smoke. FastSense is available in 3 models: FastSense 25, FastSense 100, FastSense PLUS. The FastSense 25 accommodates sampling pipe up to 25 metres in length while the FastSense 100 and FastSense PLUS has total sampling pipe capacity of 100 metres and 200 metres respectively. Advanced Laser Technology ClassiFire Artificial Intelligence software Patented Wastegate system In-built bar-graph and smoke level display; and programming (Available only with the FastSense PLUS) Apollo Protocol Interface Card Interface (APIC) provides portal for indication and control of FastSense detectors at Ampac s FireFinder Fire Alarm Control Panel FASTSENSE Models PLUS 27 VDC 27 VDC 27 VDC 250mA 400mA 400mA Dimensions (mm) Height Width Depth High Sensitivity Detection System The HIgh Sensitivity detectors are complemented by a range of light grey fittings intended to ensure that the system will suit most applications. Pipes, printed with red markings, have bell ends for easy fit to the next pipe, thus saving time and material (less need for coupling for pipe joins). T-piece is available with friction or lock fitting. The friction fit sampling points are aesthetically designed and have an easy fit finger twist lock nut. Resilient snap-on conduit saddle clips and collars, are a boon for installers. Sampling kits are available with either friction or locking TPiece and also includes a one (1) metre sampling tube and sampling point Sampling pipe plug available for extending sampling point whilst being unobtrusive. Item Numbers Pipe (4M Length) Pipe Coupling Std DX Pipe Coupling IP65 DX FitAncilliaries Large 90 o Bend - Standard End Cap 25mm DX Pipe Clip Saddle GW Pipe Clip Mounting Rail GW Label Sampling Pipe Roll Sampling Point Kit 10mm - Friction Fit Sampling Point Kit 10mm - Locking Tube - 10mm (100 metre roll) natural Wagner Reducer Film 2.0mmGrey Standard-Grey Wagner Reducer Marking Tape Relay Outputs (All normally open 1 Amp) Fire 1 Optional Optional Fitted Fire 2 Optional Optional Fitted Pre-Alarm Optional Optional Fitted Auxiliary Optional Optional Fitted Fault Optional Optional Fitted No. of Pipe Inlets Max. Pipe Length 25m 100m 200m Sensitivity Range Minimum 25% 25% 25% Maximum 0.03% 0.03% 0.03% Data Bus 1.2km 1.2km 1.2km IP Rating IP50 IP50 IP50-10 C to +60 C Humidity 0 to 90% non-condensing 1.7kg 3.8kg 5.2kg Approvals AS Item Numbers FastSense 25 detector & docking station FastSense 100 detector & docking station FastSense PLUS detector FastSense PLUS detector + command module FastSense Range Apollo XP95 Interface (APIC) FastSense 25/100 Dust Filter FastSense Plus Dust Filter

38 74 Audio Visual & Interafaces 75 Ampac Interfaces Single Input/Output Device The Ampac Single Input Output Device is designed to interface to a variety of plant control equipment such as door contacts, sprinkler flow switches and fire fan control systems. Loop Powered Monitored Input Change Over Relay Output Compatible with XP95 & Discovery Protocol Built In Short Circuit Isolator Low Power Consumption Diagnostic LED Indications Surface Mount Enclosure DIN Rail Mount Option Single Input Output Device DIN Mount Single Input Output Device Enclosed Single Input Device DIN Mount Single Input Device Enclosed Three Input Output Device The Ampac Three Input Output Device is designed to interface to a variety of plant control equipment such as door contacts, sprinkler flow switches, gas valves and fire fan control systems. Ampac offer an extensive range of addressable Interface devices which have a new uniform sleek design for ease of installation and commissioning. Designed for the monitoring and controlling of many types of essential plant equipment, the Interface devices enable fire protection solutions to be engineered simply and effectively without the need for specialist enclosures. 3 x Independent Monitored Inputs 3 x Change Over Relay Outputs Loop Powered inc Short Circuit Isolator Compatible with XP95 & Discovery Protocol Low Power Consumption Diagnostic LED Indications Surface and DIN Mount Enclosures Three Input Output Device DIN Mount Three Input Output Device Enclosed Three Input Device DIN Mount Three Input Device Enclosed The range includes both single and 3 channel input output devices together with a zone input device that may be mounted in bespoke enclosures, direct surface wall mounted or DIN rail mounted. Input / Output Input Zone Input 3 Input / Output 3 Input Operating voltage 17 to 28 V dc at 24 V dc 1.25mA 1.25mA 7.5mA 1.31mA 1.25mA Max loop current at 24 V dc 2mA 1.51mA 3.6mA 1.59mA 1.54mA Output rating 1A at 30V ac/dc N/A 1A at 30V dc 1A at 30V ac/dc N/A Operating temp -20 C to +70 C (no icing) Dimensions - DIN 110W x 75H x 25D mm 144W x 75H x 25D mm Dimensions - Enclosed 150W x 200H x 52D mm 150W x 200H x 52D mm IP Rating IP44 Zone Input Device The Zone Input Device is designed to allow up to 40 conventional detectors to be interfaced to the Ampac range of Apollo analogue addressable control panels. Conventional Monitored Input Selectable EOL Monitoring Device Loop Powered Compatible with XP95 & Discovery Protocol Built In Short Circuit Isolator Low Power Consumption Diagnostic LED Indications Surface Mount Enclosure DIN Rail Mount Option Zone Input Device DIN Mount Zone Input Device Enclosed

39 76 Audio Visual & Interafaces 77 XP95 Interfaces Input/Output Unit with Isolator The Input/Output unit with Isolator provides a voltage free, single, pole, change-over relay output, a single, monitored switch input and an unmonitored, non-polarised opto-coupled input. It can report fault, switch open and switch closed levels Three visible LEDs Loop powered free Capable of switching up to 1A at 30V Built-in short circuit isolator Input Unit with Isolator Output Unit with Isolator Zone Monitor with Isolator The Zone Monitor with Isolator powers and controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery or XP95 Loop. Loop powered Visible LED Built-in short circuit isolator Discovery/XP95 Zone Monitor with Isolator There are a variety of XP95 interfaces available to suit a number of individual applications. Standard interfaces are fitted with bi-directional short circuit isolators so that they are unaffected by a single short circuit on either loop input or output. The exception to this is the Main Input/Output Unit which is not isolated. DIN-Rail interfaces feature enclosures that clip to standard 35mm DIN rails or are screwed to the base of a larger enclosure. They enable fire system designers to create multi-purpose interfaces for individual sites. Operating voltage Quiescent current at 24 V dc Max loop current at 24 V dc Input / Output 1.25mA Zone Monitor 4mA + detectors Sounder Unit Switch Monitor (inc Plus) 17 to 28 V dc Mains Input / Output 3 Input / Output Mini Switch Monitor 1.95mA 1.25mA 1.25mA 3mA 200 μa 3.5mA 11mA 3.6mA 4.2mA 3.5mA 7.5mA 3.4mA Output rating 1A at 30V dc N/A 1A at 30V dc 1mA (opto) 5A at 250V ac 1A at 30V dc N/A Operating temp -20 C to +70 C (no icing) Dimensions 150W x 90H x 48D mm grams 621 grams 30 grams IP Rating IP54 IP54 - Sounder Control Unit with Isolator The XP95 Sounder Control Unit with Isolator is used to control the operation of a zone of conventional sounders and report their status to the control panel. Allows sounders to be operated continuously or be pulsed or be pulsed, 1 second on 1 second off May be synchronized when in pulsed operation Sounder Control Unit with Isolator Three Channel Input/Output Unit with Isolator The Three Channel Input/Output unit with Isolator provides three voltage free, single pole, change-over relay outputs, and three monitored switch inputs. Supervises one or more normally-open switches on each of the three inputs Loop powered Capable of switching up to 30V at 1A on each of the three outputs Built-in short circuit isolator Three Channel Input/Output Unit with Isolator

40 78 Audio Visual & Interafaces 79 XP95 Interfaces Mains Switching Input/Output Unit The XP95 Loop Powered Mains Switching Input/ Output Unit provides a voltage free, single pole charge- over relay output and a monitored switch input. Supervises one or more normally-open switches connected to a single pair of cables Three visible LEDs Capable of switching 250 vac at up to 5 amps Mains Switching Input/Output Unit Mini Switch Monitor with Isolator The Mini Switch Monitor is an interface within an entirely new housing. This allows the unit to be fitted onto a standard 35mm DIN-Rail (using a twist-click motion) or mounted within an enclosure, for example a Manual Call Point. It is designed to monitor the state of one or more single pole, volt-free contacts connected on a single pair of cables and to report the status to the FireFinder or LoopSense addressable control equipment. Alarm Acknowledgement Facility The Alarm Acknowledgment Facility (AAF) is a loop powered addressable device that helps reduce the costly consequence of an unwanted alarm. Operating 21 to 28 VDC (loop powered) Quiescent Current 900µAA at 24VDC Additional Operational Currents Ext Hush enabled +100µA Poll LED ON steady +2mA Alarm LED ON steady & buzzer sounding Ia = <8mA Temperature -20 C to 70 C Humidity (Non Condensing) 0 to 95% Address Setting 1 to 126 Alarm Current <8mA at 24VDC Dimension Single gang Clipsal plate 45 grams Compliance AS and AS amendment 1 Alarm Acknowledgement Facility AS Alarm Acknowledgement Facility Horizontal AS Designed for use where space is limited Built in short circuit isolator Interrupt/non interrupt in one unit Pre-alarm status available Three coloured LEDs giving clear status indication XP95 Mini Switch Monitor with Isolator Apartment Module The Apartment Module (AM) is a loop powered addressable device that helps reduce the costly consequences of an unwanted alarm Operating 21 to 28 VDC (loop powered) Quiescent Current 4.9mA with 6k2Ω EOL 1.9mA with 10μF EOL Alarm Current 4.2mA + Zone alarm current of 14.5mA Zone Circuit 10 detectors (max) with 6k2Ω EOL (detector current < 1.2mA) 20 detectors (max) with 10μF EOL (detector current < 2.4mA) Zone EOL 6k2Ω, 10μF Speaker Circuit 100Volt line, 6 W max, 47k EOL Address Setting 1 to 126 Dimension Single gang PDL plate Material High impact ABS (white) 45 grams Apartment Module

41 80 Audio Visual & Interafaces 81 Conventional Audio Visual Vantage Sounder The Vantage spatial sounder has been designed for general purpose, fire and security applications and incorporates AS compliant signal tones. Operating voltage 21-28VDC Volume setting Low Med High 24VDC 9mA 18mA 36mA Sound 1m (Tone 1) 86dBA 101dBA 106dBA Number of tones 32 IP Rating (shallow) IP43 IP Rating (deep) IP65-20 C to +70 C (no icing) Humidity Dimensions (mm) 94Ø x 85H(shallow), 94Ø x 102H (deep) 200g (shallow), 220g (deep) Approvals EN54-3, AI 2002, A Vantage Sounder Red with Shallow Base Vantage Sounder White with Shallow Base Deep Base Only Red Deep Base Only White Vantage Combi The Vantage Combi is a combined low profile electronic reflex horn sounder incorporating a high output LED cluster strobe array. The Vantage Combi has been designed for general purpose, fire and security applications and incorporates AS compliant signals. 18 to 35 VDC Volume setting Low, Med & High Current 27VDC ) 11-48mA Sound Output 1m) dB Signal AS Flash rate 1 per sec Size (shallow) 93mm Dia x 90mm H Size (deep) 93mm Dia x 107mm H Temperature range -20 C to +70 C Humidity 0 to 95% IP Rating (shallow base) IP43 IP Rating (deep base) IP65 223g & 253 Approvals AS Deep Base Only Red Deep Base Only White Vantage Combi Red with Shallow Base Vantage Combi White with Shallow Base Amber Sounder Beacon White Deep Body (VTB-32 Tone) Vantage LED Beacons Designed as a general purpose LED beacon for fire, security and industrial applications, the Vantage Beacon incorporates the latest in energy efficient LED technology to provide maximum all-round visibility in an aesthetically pleasing body with minimum power requirements. Operating Supply Current Flash Rate Operating Temp. Humidity Material Dimensions Shallow Base Deep Base 20-35V DC 9mA T3 Temporal (red & clear) 1Hz (amber) -20 C +70 C 0 to 95% Non-condensing ABS fire retardant plastic 94mm Ø x 60mm H 94mm Ø x 77mm H IP43 (shallow), IP65 (deep) 145g (shallow), 165g (deep) Red LED Beacon White Shallow Body Amber LED Beacon White Shallow Body Red LED Beacon White Deep Body Amber LED Beacon White Deep Body Red LED Beacon Red Deep Body Amber LED Beacon Red Deep Body Clear Lens Red LED Beacon White Shallow Body Vector Sounder The Vector sounder has been designed for general purpose conventional fire detection applications and incorporates AS compliant signal tones. The Vector sounder can be installed as a sounder base for Ampac conventional detectors or a surface mount sounder when used in conjunction with the optional lid Operating voltage 8 to 35 VDC Supply current Evac 24VDC Supply current Alert 8 24VDC Signal output AS Max. Output level 91 1 metre with detector Evac 93 1 metre with lid Volume control -30dBA IP42 Temperature range -20 to + 70 C Construction ABS Dimension (mm) 106Ø x 35h (Sounder & lid only) Vector Sounder Vector Sounder Lid

42 82 Audio Visual & Interafaces 83 Conventional Audio Visual Vantage Dual LED Beacon The Vantage Dual LED Beacons are designed for use with the EV3000 Emergency Warning and Intercommunication Systems. Incorporating the latest in LED technology, the Vantage beacon offers maximum all-round visibility in an aesthetically pleasing body with minimum power requirements. The low current features of the product allow installers to use a larger number of visual devices on the EV3000 which negates the need for additional output circuits and power supplies. Operating Supply Current Flash Rate Operating Temp. Humidity Material Dimensions Flush Surface 18-35V DC 9mA T3 Temporal (red), 1Hz (amber) -20 C +70 C 0 to 95% Non-condensing ABS fire retardant plastic 188mm L x 94mm W x 62mm H 188mm L x 94mm W x 80mm H IP43 (shallow), P65 (deep) 215g (shallow), 235g (deep) Dual LED Beacon Shallow Base Dual LED Beacon Deep Base Remote Indicators Fire Alarm Remote Indicator - Round Ampac offer a range of remote indicators which are designed for fire detection systems requiring local indication of an individual or group of detection devices located in concealed areas. Applications include floor and ceiling voids spaces, roof spaces, lift shafts and escalator machine rooms. Current at 24v Size 24 VDC 1.5mA 74mm Dia x 16mm H 26 grams Remote Indicator Fire Alarm in Concealed Space Remote Indicator Fire Alarm in Roof Space Remote Indicator Fire Alarm in Room Remote Indicator Fire Alarm in Duct Remote Indicator Fire Alarm in Cupboard Remote Indicator Fire Alarm Under Floor Remote Indicator Fire Alarm in Return Air Remote Indicator Fire Alarm in Exhaust Duct Remote Indicator Fire Alarm in Supply Air Duct Remote Indicator Fire Alarm in Ceiling Remote Indicator Fire Alarm Above Remote Indicator Fire Alarm Remote Indicator Detector Activated Beacon / Strobe Sign Plate The beacon / strobe sign plate mounts directly behind the single Beacon or Sounder/ Beacon and is generally located outside the main entrance to the building to attract the attention of approaching fire fighters. Fixing Strobe / Beacons Material Size Directly behind the Sonos Model Painted metal 1mm 120mm W X 160mm H Vantage Sounder / Beacon FIRE Legend Plate ASL-86 Strobe FIRE Legend Plate Xenon Strobes AMPAC offer the flexibility of individual red and amber strobes or a combined red/ amber strobe unit, complete with mounting box and terminals. 24 VDC Current 140mA Rating 10 Watts Size inc base 100Dia x 88H mm Flash rate 75 per minute -20 C to + 60 C IP65 strobe 182 grams combined unit 719 grams Indicator / Buzzer & Indicator / Buzzer with Mute Alarm activation indicator and buzzer 10mm red flashing LED Buzzer (with mute facility) Modern styling Indicator / Buzzer Current at 24v LED flash rate Buzzer Size Indicator / Buzzer with Mute Current at 24v LED flash rate Buzzer Size 24 VDC 27mA 45 per minute 114dBA 70H x 110W x 10D mm 64g 24 VDC 43mA 45 per minute 114dBA 70H x 110W x 10D mm 89g Flashing Indicator / Buzzer Flashing Indicator / Buzzer with Mute Switch V Strobe Light Red ASL V Strobe light Amber ASL V Strobe Light Combined Red/Amber

43 84 Audio Visual & Interafaces 85 Bells Warning Signs Fire Alarm Bell 150mm The Fire Alarm Bell is a motorised, maintenance free bell designed for fire alarm applications. Its low current consumption, ease of installation incorporating diode polarity suppression and universal recognisable bell sound, makes it an ideal choice for fire alarm installations. Operating current Size (without back box) Sound level Fire Alarm Bell 200mm The Fire Alarm Bell incorporates a solenoid actuation mechanism and is designed for fire alarm applications. Its low current consumption, ease of installation incorporating diode polarity suppression and traditionally recognisable bell sound, makes it an ideal choice for fire alarm installations. Operating current Size (without back box) Sound Level Bell Back Box Surface mounting of bell box designed for use with the 150mm and 200mm Bell. Material Finish Depth 12V DC or 24V DC 55mA or 25mA 150mm Dia x 56mm D 92 1m -10 C to +55 C (no icing) 764 grams AFB-63 Bell 150mm Red 24VDC AFB-63 Bell 150mm Red 12VDC VDC 100mA 200mm Dia x 70mm D 85 3m -20 C to +70 C (no icing) 1.25kg Bell 200mm 24v dc Red Cast Aluminium Red 40 mm 270 grams Bell Back Box The Ampac range of Warning Signs offer state of the art LED technology for a variety of applications in a highly aesthetic design. The slimline enclosure can easily be adapted to surface or semi-flush mounting while a range of standard fascia plates has been developed to suite Agent Release applications. A weatherproof version is also available along with custom legend fascia plates. A maximum of 6 Warning Signs can be connected to the output of each Agent Release module located within the ZoneSense, FireFinder or LoopSense fire control panels. Low Power Consumption High Efficiency LED Indications Aesthetically Pleasing Two or Three Wire Connectivity Single or Dual Level Operation Continuous or Flashing LED Operation Synchronisation between Signs Integral Buzzer with Mute Facility External Sounder Output Surface or Semi-Flush Fixing Waterproof Version Operating 17 Vdc to 29 Vdc Power Consumption Level 1 active 50mA at 24 Vdc Level 1 & 2 active 100mA at 24 Vdc Operating Temperature -20 C to +55 C Humidity 0% to 95% non condensing IP IP65 Material ABS Enclosure / Acrylic Fascia Dimension (mm) H x 325W x 50D H x 338W x 67D Item Numbers Warning Sign (no fascia plate) Warning Sign IP65 (no fascia plate) Fire Alarm - Do Not Enter (fascia plate only) Fire Alarm - Evacuate Area (fascia plate only) Do Not Enter - Gas Discharged (fascia plate only) Fire Door Closing (fascia plate only) Extinguishing System Inoperative (fascia plate only) Custom Legend (specify text) Wall / Ceiling Mount Surround - Smart Term/Warning Sign Dual Ceiling Mount Surround for Warning Sign

44 86 Audio Visual & Interafaces 87 Speakers One-Shot Ceiling Speaker The 100mm and 200mm One Shot ceiling speakers are ideal for use in a wide range of applications including Emergency Warning Systems (EWS), Background Music and Public Address (PA) paging within shopping centres, offices and hotels. The One Shot speaker units install in seconds. They simply snap fit to any 10-13mm thickness ceiling by means of the 3 integral pressure clips. Rated Power 5 watts Line 100 Volt Frequency R esponse 100 Hz to 15 khz SPL 98 db (1 0.5m) Speaker Tap (watt) 0.33, 0.66, 1.25, 2.5, 5 Cut-out size 140 mm Diameter Dimensions 155 x 110 Hmm 850 grams Ceiling Speaker 100mm One-Shot (White) Ceiling Speaker 100mm One-Shot (Black) Ceiling Speaker 200mm One-Shot (White) One Shot Combo Speakers (Box Qty 32) One Shot Combo Grills (Box Qty 32) Ceiling Speaker 100mm Recessed The 100mm speaker is ideal for use in a wide range of applications including Emergency Warning Systems (EWS), Background Music and Public Address (PA) paging within shopping centres, offices and hotels. Rated Power 5 watts Line 100 Volt Frequency R esponse 100 Hz to 20 khz SPL 96 db (1 0.5m) Speaker Tap (watt) 0.33, 0.66, 1.25, 2.5, 5 Cut-out size 85 mm Diameter Dimensions 100 x 105 Hmm 800 grams Ceiling Speaker 100mm Recessed Low Profile Grill Ceiling Speaker - 200mm Recessed The 200mm speaker is ideal for use in a wide range of applications including Emergency Warning Systems (EWS), Background Music and Public Address (PA) paging within shopping centres, offices and hotels. Rated Power 5 watts Line 100 Volt Frequency R esponse 100 Hz to 20 khz SPL 96 db (1 0.5m) Speaker Tap (watt) 0.33, 0.66, 1.25, 2.5, 5 Cut-out size 190 mm Diameter Dimensions 200 x 75 Hmm 1 kg Surface Speaker - 100mm The Surface Mount 100mm Speaker is an excellent choice for use in plant rooms, warehouses, shopping centres and malls. The custom designed speaker and transformer assembly has been engineered to meet Australian Fire Evacuation Standards Driver Power taps SPL 1m Frequency response Connection 100mm (4 ) dual cone 0.33, 0.66, 1.25, 2.5, 5W 1kHz (+/- 2dB) 100Hz-15kHz 4 way terminal block + 22uF bipolar capacitor Surface Speaker 100mm EasyFit Ceiling Speakers The EasyFit range of Ceiling Speakers are lightweight, quick and easy to install, and are finished in unobtrusive white with an attractive metal grille. The EasyFit Ceiling Speaker offers a wide frequency range along with good sound dispersion ensuring quality music reproduction and excellent speech intelligibility. 4 Inch 5 Watt 6 Inch 10 Watt 8 Inch 15 Watt 8 Inch 30 Watt Driver Maximum/rated power 8W/5W 15W/10W 22W/15W 45W/30W Power taps 5, 2.5, 1.25, 0.66, 0.33W 10, 5, 2.5, 1.25W 15, 10, 5, 2.5, 1.25W 30, 15, 7.5, 3.75W Frequency Range 100Hz - 15kHz 60Hz - 20kHz 50Hz - 17kHz 50Hz - 17kHz Axial sensitivity 1W/1m/1kHz 94dB SPL 91dB SPL 93dB SP 93dB SPL Opening Angle( -6dB) 144 / 93 at 1kHz / 4kHz 170 at 1kHz 165 at 1kHz 100 at 1kHz Ceiling cutout diameter 140mm 195mm 238mm 238mm Overall dimensions 170mm x 110mm 220mm x 115mm 273mm x 103mm 273mm x 115mm Safety acc to EN acc to EN acc to EN acc to EN 6006 Ceiling Speaker, Easyfit 5w 4 - EVAC Ceiling Speaker, Easyfit 5w 5 - Brilliant White Ceiling Speaker, Easyfit 5w 5 White Ceiling Speaker, Easyfit 10w Ceiling Speaker, Easyfit 15w 8 White Ceiling Speaker, Easyfit 30w 8 White Ceiling Speaker 200mm Recessed Low Profile Grill

45 88 Audio Visual & Interafaces 89 Speakers Addressable Audio & Visual Horn Speaker - 10 Watt The Ampac 10 Watt/ 20 Watt Horn Speaker is specifically designed for distributed Public Address (PA) and Emergency Warning Systems (EWS) with frequency response characteristics ensuring clear speech reproduction during announcements. Rated Power 10 watts Line 100 Volt Frequency R esponse 250 Hz to 13 khz SPL 105 db (1 1m) Speaker Tap (watt) 1.25, 2.5, 5, 7.5, 10 Dispersion angle 110 Material UV stabilised plastic IP Rating IP65 Dimensions 150 Dia x 190 Dmm 1.4 kg Horn Speaker 10 Watt Horn Speaker 20 Watt Horn Speaker Bracket Wurli-Gig Integrated Sounder Base The Integrated Sounder Base comprises a base sounder with integral mounting base and is for use with Discovery or XP95 ranges. It is designed for indoor use. (polarity sensitive) Max current (sounder operated) Max sounder output Size VDC 1.2mA 5mA 92dB(A) -20 C to +60 C (no icing) IP21D 115Dia x 38H mm 140 grams Integrated Base Sounder White Cap Horn Speaker - 10 Watt / 20 Watt The High Efficiency Ampac 10 and 20 watt horn loudspeaker is specifically designed for distributed Public Address (PA) and Emergency Warning Systems (EWS) with frequency response characteristics ensuring clear speech reproduction during announcements. 10 Watt 20 Watt Rated input 100V 100V Power handling 10W 20W Power taps 10, 7.5, 5, 2.5, 20, , , 5W SPL at Rated Power 1m) 119 db 124 db SPL at Rated Power 1m) 108 db 110 db Frequency Range (-10dB) 300Hz - 13kHz 9kHz Dispersion Angle(-6dB) 1.3KG 2.1KG Horn Speaker Bosch Easy Fit 10W IP66 Grey Horn Speaker Bosch Easy Fit 20W IP66 Grey Addressable Beacon Base The Beacon Base is a loop-powered beacon combined with a standard Intelligent Mounting Base. It is used to signal a fire alarm in enclosed areas. The Beacon Base can be used either with a detector fitted or with a cap for operation as a stand-alone alarm device. (polarity sensitive) Max current (sounder operated) Max sounder output Size VDC 300μA at 24V DC 3.1mA at 24V DC 92dB(A) -20 C to +60 C (no icing) IP21D 115mm Dia x 31mmH 109 grams Beacon Base White Cap

46 90 Audio Visual & Interafaces 91 Addressable Audio & Visual Sounder Beacon Base The Sounder Beacon Base is a loop-powered sounder and beacon combined with a standard Intelligent Mounting Base. It is used to signal a fire alarm in enclosed areas. The Sounder Beacon Base can be used either with a detector fitted or with a cap for operation as a stand-alone alarm device. (polarity sensitive) VDC + Beacon 300µA Max current (sounder operated) 8mA Max current (beacon only) 3.1 ma Max sounder output 91dB(A) -20 C to +60 C (no icing) IP21D Size 115Dia x 38H mm 160 grams Sounder Beacon Base Beacon Base White Cap Intelligent Open-Area Beacon The Intelligent Open-Area Beacon has been developed for use in situations where there is a risk that sounders will not be heard. It is weatherproof and can be used outside. (polarity sensitive) VDC 333µA Max current (beacon operated) 3.1mA Flash rate 1Hz -10 C to +55 C (no icing) IP65 Size 104Dia x 97.5H mm 205 grams Intelligent Open Area Beacon (Red) Sonos Intelligent Open Area Beacon (Clear) Sonos Loop-Powered Beacon The Loop-Powered Beacon is a local-area beacon designed for indoor use. The beacon has been developed as a supplement to sounders for use in situations where there is a risk that sounders will not be heard. (polarity sensitive) VDC 150µA Max current (beacon operated) 3mA Flash rate 1Hz -20 C to +60 C (no icing) IP23D Size 115Dia x 38H mm 140 grams Loop-Powered Beacon (Red) Loop-Powered Beacon (Amber) Standard Flash Loop-Powered Beacon (Clear Lens/Red Flash) Standard Flash Intelligent Open-Area Sounder / Sounder Beacon The Intelligent Open-Area Sounder /Sounder Beacon has been designed for use in open areas and can be connected to any Discovery or XP95 system. Sounder Sounder/Beacon (polarity sensitive) VDC 333µA Max current 5mA 8mA (sounder/beacon operated) Max sounder output - 1Hz -10 C to +55 C (no icing) IP65 Size 104Dia x 97.5H mm 225 grams 260 grams Intelligent Open Area Sounder (Red) Sonos Intelligent Open Area Sounder (White) Sonos I ntelligent Open Area Sounder Beacon (Red) Sonos Intelligent Open Area Sounder Beacon (Clear) Sonos

47 92 Audio Visual & Interafaces 93 Hazardous Area - Intrinsically Safe Hazardous Area- Flameproof Equipment The Intrinsically Safe range of products includes the compact I.S. Sounder, I.S. Beacon and I.S. Sounder / Beacon. The range is suitable for all intrinsically safe signalling applications including fire, security and process control. Approvals include ATEX and IECEx and GOST-R for Zone 0 applications and FM approval for Class I Division 1 and Class I Zone 0 applications. The I.S. Beacon optimises the effectiveness of its six high output LEDs via a prismatic lens design. The I.S. combined Sounder and Beacon requires only one Zener barrier or galvanic isolator to run both sounder and beacon or alternatively the unit can be operated as individual signals. Power to the I.S. range should be via a certified zener barrier or galvanic isolator whose output parameter is no greater than, Uo=28v dc, Io=93mA,and Po=660mw. The beacon is internally input overload and reverse polarity protected and is end of line monitoring resistor certified. Input Overload and Reverse Current Protection End of Line Resistor Certified ATEX and IECEx approval 2 x M20 clearance gland knockouts Auto Synchronised Sound Output (exc. Beacon) Sounder Beacon Sounder/Beacon Range 16-28Vdc via Zener barrier or galvanic isolator Nominal Current Consumption 25mA at 24V DC 25mA at 24V DC 30mA at 24V DC Energy - double flash at 2Hz and 1Hz Flash Rate - 23cd 23cd Sound Output (nominal) at 1m +/- 3dB Tone 2 100dB(A) 100dB(A) Number of Tones Temperature range -40 to +60 C Protection rating IP65 Boxed weight Red Body Colours Red, Amber, Clear Item Numbers I.S. Sounder Red Body I.S. Beacon Red Body, Red Lens I.S. Beacon Red Body, Amber Lens I.S. Beacon Red Body, Clear Lens I.S. Sounder Beacon Red Body, Red Lens I.S. Sounder Beacon Red Body, Amber Lens I.S. Sounder Beacon Red Body, Clear Lens Sounder/Beacon Solenoid Driver Single Channel Sounder/Beacon Solenoid Driver Dual Channel Sounder Circuit Zener Barrier The flameproof range of products is ideal for hazardous areas, specifically Zone 1 and 2 applications. The use of flameproof technology ensures that engineers installing into hazardous areas need not fit an intrinsically safe barrier and the associated wiring requirements. Sound level outputs are up to 117dB(A) at 1 metre with a choice of 32 alarm tones and 3 remotely selectable stages. Housings are manufactured from corrosion proof, marine grade copper free LM6 aluminium which is phosphated and powder coated. All models have two M20 cable entries, large termination areas and an ingress protection of IP66/67. Two entry points for cabling are present for IN and OUT wiring, thus eliminating the requirement for additional flameproof junction boxes. ATEX and IECEx approval Rapid installation with no barrier requirements Suitable for Zone 1 & 2 flameproof applications Large termination area Ratchet adjustable stainless steel U bracket Synchronisation on multi-sounder systems Sounders have 32 synchronised tones available Beacon Sounder Sounder/Beacon Range 20-28V DC 20-28V DC 20-28V DC Nominal Current Consumption 300mA 265mA 565mA Energy 5 joules (5Ws) - 5 joules (5Ws) Flash Rate 1Hz (60 fpm) - 1Hz (60 fpm) Sound Output (nominal) at 1m +/- 3dB Tone 2-110dB(A) 110dB(A) Number of Tones Temperature range -50 to +70 C -50 to +70 C -50 to +70 C Protection rating P66/67 IP66/67 I P66/67 Boxed weight 2.45Kg 3.2Kg 4.8Kg Body Colours Red Item Numbers BEx Flameproof Sounder Red Body BEx Flameproof Beacon Red Body, Red Lens BEx Flameproof Sounder Beacon Red Body, Red Lens

48 94 Cable 95 2 Core TPS Cable AMPAC Safety s CableSAFE cables are manufactured and approved for use in Fire Detection and Emergency Warning Systems. CableSAFE cables are available with coloured sheath stripes on Red Sheath to differentiate between detector and ancillary circuits. A twisted version is available for use in addressable loop cabling when reduced line noise is essential. Red Sheath for Fire Alarm Application as specified for Fire Alarm use White, blue or yellow stripe on red sheath for fire related systems StripEasy Sheath Metre markings Available in flat and twisted AS/CAS008 compliant 200m and 500m rolls available Approved to: AS/NZS Cable Construction AS/CAS008 ACMA Compliance N31145 AS/NZS1125 Conductors AS/NZS3808 Insulation & Sheath Applications Fire Systems Addressable Loop Addressable Interfaces Conventional Zones Sounders & Bells Door Holders Remote Indicators Agent Release Warning Signs Warning Systems Ceiling Speakers Horn Speakers Visual Warning Devices Specifications Item Number 2 Core TPS Cable Cross Section mm2 TPS Flat 2c 0.75mm - 200M TPS Flat 2c 0.75mm - 500M TPS Flat 2c 0.75mm White Stripe - 200M TPS Flat 2c 0.75mm White Stripe -500M TPS Flat 2c 0.75mm Yelllow Stripe - 200M TPS Flat 2c 0.75mm Yelow Stripe - 500M TPS Flat 2c 0.75mm Blue Stripe - 200M TPS Flat 2c 0.75mm Blue Stripe - 500M TPS Flat 2c 1.0mm White Stripe - 200M TPS Flat 2c 1.0mm White Stripe - 500M TPS Flat 2c 1.5mm - 200M TPS Flat 2c 1.5mm - 500M TPS Flat 2c 1.5mm White Stripe -200M TPS Flat 2c 1.5mm White Stripe - 500M TPS Twisted 2c 1.5mm - 200M TPS Twisted 2c 1.5mm - 500M TPS Twisted Screen 2c 1.5mm -200M TPS Twisted Screen 2c 1.5mm - 500M Core TPS Cable Halogen Free Conductor Strands/ Dia Core Configuration Stripe Colour Overall Size mm Std Drum Length Std Drum Length / 0.37 Flat x M / 0.37 Flat x M / 0.37 Flat White 6.2 x M / 0.37 Flat White 6.2 x M / 0.37 Flat Yellow 6.2 x M / 0.37 Flat Yellow 6.2 x M / 0.37 Flat Blue 6.2 x M / 0.37 Flat Blue 6.2 x M / 0.43 Flat White 7.1 x M / 0.43 Flat White 7.1 x M / Flat x M / Flat x M / Flat White 8.0 x M / Flat White 8.0 x M / Twisted x M / Twisted x M / Screened M / Screened M 93 Item Numbers TPS Flat Hal Free 2c 1.5mm- 500M TPS Twisted Hal Free 2c 1.5mm - 200M

49 96 Ancillaries 97 Ancillaries Electro-Magnetic Door Holders Electro Magnetic Door Retainer The AMPAC Door Retainer enables doors to be held open under normal conditions and released during a fire alarm condition. They are simple to install and commission and are suited to a wide range of applications including Hospitals, Schools, Manufacturing Plants and Office Buildings. Operating 15 to 29 VDC Operating Current 24 VDC Holding Force 50kg Housing White High Temperature ABS Operating Temperature -10 to +55 C Dimension (mm) 100h x 100w x 50d IP g Approval C-Tick Ampac Door Holder 24VDC 50KG Surface Mount Door Holder The Surface Mount Door Holders combine good looks, high performance and economy in a low profile package. Designed to allow doors to be held open under normal conditions and released during a fire alarm condition, the Surface Mount Door Holders are simple to install and commission and are suited to a wide range of applications including: Ampac offers a wide range of Ancillary devices for use in conjunction with its range of intelligent and conventional detectors and control panels. A versatile and functional range offering a huge choice for any application. Products incude: Electro magnetic door retainters MultiAmp PSU Key Holders Wall Boxes Document cabinets Sealed Rechargable Lead-Acid Batteries /3/4 1002/5 Operating 24V dc 230V ac Current 50mA 12mA Dimensions (mm) ABS 87 W x 95 H x 46 D Steel 86 W x 86 H x 62 D Manual Release Yes Operating Temp. -10 to +50 C IP51 Finish White Fire Resistant ABS Approvals EN1155 Surface Mount 200N 24V ABS Case Door Holder Surface Mount 200N 230V ABS Case Door Holder Surface Mount 500N 24V ABS Case Door Holder Surface Mount 200N 24V Steel Case Door Holder Surface Mount 200N 230V Steel Case Door Holder Adjustable Keeper Plate

50 98 Ancillaries 99 Electro-Magnetic Door Holders Flush or Surface Mount- Metal Case The Flush Mount Door Holder is built around a robust fascia plate for flush mounting on a back box. The Surface Mount unit is supplied with a back box incorporating 20mm knockouts. Designed to allow doors to be held open under normal conditions and released during a fire alarm condition, the Door Holders are simple to install and commission and are suited to a wide range of applications including: / /1005 Operating 24V dc 230V ac Current 50mA 12mA Dimensions (mm) Flush Mount 86 W x 86 H x 43 D Surface Mount 86 W x 86 H x 62 D Manual Release Yes Operating Temp -10 to +50 C IP51 Finish Nickel Coated Painted White Approvals EN1155 Flush Mount 200N 24Vdc Door Holder Flush Mount 200N 230Vac Door Holder Universal Door Holder The Universal Door Holder is designed for floor, ceiling or wall mount applications and enables doors to be held open under normal conditions and released during a fire alarm condition. The Universal Door Holder is simple to install and commission and is suited to a wide range of applications including: / / 04 Operating 24V dc Current 43mA 76mA Stand Length (mm) Floor Mount H1 183 / 282 Steel 250 / 350 Manual Release Yes Operating Temp -10 to +50 C IP51 Finish Nickel Coated Painted White Approval EN1155 Universal Mount 500N Short Stand 24V Door Holder Universal Mount 500N Long Stand 24V Door Holder Universal Mount 1000N Short Stand 24V Door Holder Universal Mount 1000N Long Stand 24V Door Holder Floor Mount Door Holder The Floor Mount Door Holder features rugged cast aluminium housing, a holding electromagnet with integral anti-residual ejection pin and a manual release switch / /4 Operating 24V dc Current 45mA 90mA Dimensions (mm) 110 W x 95 H x 96 D Manual Release Yes Operating Temp. -10 to +50 C P51 Finish Aluminium White Housing Zinc Plated Magnet Approval EN1155 Floor Mount 200N 24V Cast Aluminium Door Holder Floor Mount 500N 24V Cast Aluminium Door Holder Floor Mount 200N 24V Vandal Proof Door Holder Floor Mount 500N 24V Vandal Proof Door Holder Decorative Flush or Surface Mount Decorative Door Holders are particularly suitable for installation in prestigious projects such as Hotels, Offices, Historical Buildings and Museums. Built around a robust fascia plate for flush mounting and supplied with a back box, the Door Holders are available in Bright Chrome, Lacquered Brass or Stainless Steel finish with matching Decorative Keeper Plate /03/ /07/08 Operating 24V dc 230V ac Current 50mA 12mA Dimensions (mm) Flush Mount 86 W x 86 H x 24 D Surface Mount 86 W x 86 H x 62 D Manual Release Yes Operating Temp. -10 to +50 C IP51 Approval EN115 Chrome Flush Mount 24V Door Holder Brass Flush Mount 24V Door Holder Stainless Steel Flush Mount 24V Door Holder Chrome Flush Mount 230V Door Holder Brass Flush Mount 230V Door Holder Stainless Steel Flush Mount 230V Door Holder Chrome Surface Mount Kit Brass Surface Mount Kit Stainless Steel Surface Mount Kit Brass Keeper Plate Stainless Steel Keeper Plate Bright Chrome Keeper Plate * For product specifications, please refer to the Product Data Sheet.

51 100 Ancillaries 101 Electro-Magnetic Door Holders Power Supplies Weatherproof IP65 The Weatherproof Door Holder is ideal for most applications in all types of buildings while its high level of ingress protection means it is particularly suited to use outdoors and in marine type applications Operating 24V dc 230V ac Current 300mA 45mA Dimensions (mm) Assembly Ø 102 x 45 Keeper Plate Ø 89 x 42 Magnet 2.0kg Manual Release No Operating Temp. -10 to +50 C IP65 Finish Zinc Plated Steel MultiAmp-DH Remotely releases fire doors held open by electro magnetic door holder. Material High Impact ABS Finish White Dimension (Recessed) 91mm H X 149mm W x 40mm D (Surface) 91mm H X 149mm W x 53mm D 400g packed Mains Supply 230 VAC +/ Hz Door Holder Output mA Operating Temperature -5 to +45 C Relative Humidity 25% to 95% MultiAmp-DH 250MA Flush Mount MultiAmp-DH 250MA Surface Mount IP65 Protected 1200N 24Vdc IP65 Protected 1200N 230Vac Floor Mount Bracket A floor mounting bracket is available for the Surface Mount Door Holders. With this the Door Holder can be mounted in any convenient position on the floor to suit the door. It is supplied in a white finish with mounting instructions and is compatible with standard conduit back boxes. Floor Mounting Bracket Remote Door Release Remotely releases fire doors held open by electro magnetic door holder. Remote Door Release Plate Vertical Screen Remote Door Release Plate Horizontal Screen Chain Keeper Plate The Chain Keeper enables a wall mounted electromagnetic door holder to be used even when the door will not open fully to meet the magnet. It is a very flexible solution to awkward mounting. A one metre length of chain is supplied as standard. Keeper Plate and Mounting with 1M Chain Document Cabinets AMPAC offers ABS and metal document cabinets designed to complement the range of AMPAC s fire control panels. The cabinets can hold in excess of 100 A4 sheets of fire and security information relevant to the premises. Low Profile Keeper Plate The non-adjustable, slim style keeper plate is for use with 200N Door Holders. It is an alternative to the standard adjustable keeper design where the gap between the door and the magnet needs to be kept to a minimum. Dimensions IP Rating ABS 300mm H x 360mm W x 100mm D Metal 295mm H x 356mm W x 92mm D IP30 ABS 1kg Metal 3kg Low Profile Keeper Plate 200N Document Cabinet ABS Document Cabinet Metal Cool Grey Document Cabinet Metal White

52 102 Ancillaries 103 Power Supplies Batteries Sealed Rechargeable Lead-Acid Batteries Ampac sells a comprehensive battery range for all applications requiring a reliable rechargeable power source. The wide range of sizes coupled with good cycling ability make them perfect for critical systems such as fire alarm and emergency warning systems. Designed using VRLA technology, negating the need to add water, these batteries can be applied in many critical systems requiring reliable reserve power. Available as 12V or for very large systems 2 volt cells (x12). Extra large 12 Volt (consideration of battery cabinet space required) The MultiAmp PSU range of power supplies has been specifically designed for Fire System Installations and features intelligent battery charging and monitoring with remote fault signalling. Available in 2A, 5A or 10A versions, the MultiAmp PSU range of switch mode power supplies has been specifically designed for use with compliant fire detection and alarm systems. The units include intelligent battery charging using efficient EcoCharge technology, possess mains & battery monitoring with independent voltage free relay outputs. The units also feature battery deep discharge protection in the event of a prolonged mains failure. The inclusion of LED indicators provides quick diagnostics of the status of the power supply, while a variety of enclosures offer the installer a choice of standby battery backup options. 27.6V dc output Energy efficient operation Cost effective switch mode technology Intelligent battery charging and monitoring technology with Deep discharge protection Mains AC transient protection Remote fault signalling Space for addressable loop interface module Output (mains on) Load Output Mains Supply Environment Dimensions (mm) Material Finish Approval Item Numbers 12Ahr Enclosure 38Ahr Enclosure 65Ahr Enclosure 27.6Vdc 2.0, 5.0 & 10.0 Amps 110V ac to 230V 50Hz -10 C to 40 75%RH 330W x 280H x 121D 425W x 400H x 216D 425W x 680H x 216D IP30 1.6mm Mild Steel Power coated - Surf Mist Complies with AS Amp PSU - Space for 2 x 12Ahr Batts Amp PSU - Space for 2 x 38Ahr Batts Amp PSU - Space for 2 x 38Ahr Batts Amp PSU - Space for 2 x 38Ahr Batts Amp PSU - Space for 2 x 65Ahr Batts Amp PSU - Space for 2 x 65Ahr Batts Test Equipment 12V 1.3AH SLA Battery V 3.2AH SLA Battery V 7AH SLA Battery V 12AH SLA Battery V 18AH SLA Battery V 26AH SLA Battery V 40AH SLA Battery V 65AH SLA Battery V 75AH SLA Battery V 100AH SLA Battery V 160AH SLA Battery V 150AH SLA Battery V 230AH SLA Battery V 250AH SLA Battery V 300AH SLA Battery V 500AH SLA Battery Detector Test Equipment Access poles are used with interchangeable heads that fit onto the end of the pole. The equipment is suitable for use on a wide range of detectors. Poles are telescopic, nonconductive, toughened fibreglass. Light weight and simple to use Telescopic Pole 2.5M To 4 mtrs Single Extension Pole M Universal Detector Removal Tool Smoke Detector Test Dispenser Heat Detector Tester 240V AC Heat Detector Tester - cordless (head only) Smoke Detector Test Set metre Smoke & Mains Heat Tester Set - 6 metre Smoke & Cordless Heat Tester Set metre Battery Baton for Cordless Heat Tester Smoke Detector Test Gas 250ml Aerosol Test Gas Can Smoke 150ML (Handheld) Carbon Monoxide Smoke Can Detector Tester (Test Pole)

53 104 Ancillaries 105 Test Equipment Smoke Pen The Smoke Pen kit has been designed to provide a smooth, thin, non-volatile smoke stream and is ideal for testing High Sensitivity Smoke Detectors promoted by Ampac. The Smoke Pen incorporates a purpose designed dispenser which safely retains the smoke stick for easy use during serving and commissioning of aspirating systems. Each kit comes complete with five (5) smoke sticks offering over 4 hours of smoke stop/re-start usage) Smoke Pen Ancillary Equipment Wall Boxes Used for flush mounting devices such as manual call points and sounders Suitable for MCP models ACP-01 & FP2 Suitable for Vara sounder Size Metal Plastic Metal Plastic 72mm H x 72mm W x 47mm D 72mm H x 72mm W x 35mm D 153 grams 47 grams Wall Box Metal 25mm Deep for MCPs Wall Box Plastic 35mm Deep for MCPs Flame Sensor Test Unit and Case The Flame Sensor Test Kit is a tool which is designed to test flame detectors without the need of real flames. Flame Sensor Test Unit and Case Detector Base Mounting Block The mounting block is recommended for use when detectors are installed on uneven surfaces The mounting block ensures the correct fit with the base and the detector, improves reliability and ensures that the mounting tags on the base are not overtightened Used with Base Mounted Flame Detector Mounting Block For S65 / XP95 Base Void Fire Detector Holder Discovery Programmer The Discovery Programmer is a portable test and configuration tool for Discovery smoke and heat detectors Discovery Programmer EUR The Void Fire Detector Holder allows the installation of a fire detector within a sealed ceiling space at variable heights. The holder enables easy inspection and maintenance of the fire detector located within the ceiling void space from below ceiling level. Three models are available to suit various ceiling void heights from 0.6 metres to 3 metres. Adjustable mounting tubes Aesthetically pleasing Fixing brackets included Removable ceiling plate Void Detector Holder 1 Metre Void Detector Holder 2 Metre Void Detector Holder 3 Metre Key Holder D2 Provides a visible place to locate a key used for emergency access Red finish Instructions on glass Break glass operation similar to a manual call point Suitable for indoor use Size Finish 100mm Dia x 32mm D Red 130 grams Break Glass Key Holder D D2 Key Box Holder Spare Glass KP Wilco Detector Bracket The Willco Detector Bracket has been designed to allow installation of fire detectors within a concealed ceiling space at variable heights. The bracket assembly enables easy inspection and maintenance of the fire detector from below ceiling level. Installation is quick and easy using the existing designated false ceiling hanger along with readily available 20mm electrical conduit (not supplied). Adjustable mounting heights 3 x Height adjustment brackets included Manufactured from Galvanised Steel Wilco Detector Bracket

54 106 Ancillaries 107 Ancillary Equipment Deckhead Mounting Boxes The Deckhead Mounting Box gives extra protection to devices to be fitted in areas where there is the possibility of moisture or condensation ingressing through the rear of the base. The new version is suitable for a wider range of detector bases as well as Apollo s AV bases. Protects against water ingress. Improved performance. Available in polycarbonate or metal. Deckhead Mounting Box Metal Deckhead Mounting Box with PG16 Access Ports Metal Deckhead Mounting Box with M20 Access Ports Deckhead Adaptor (for use with converts cable glands from PG16 to M20) Head Office - Perth Ampac Technologies Pty Ltd 7 Ledgar Road, Balcatta, Western Australia, 6021 Telephone: Fax: info@ampac.net Web: Australia New South Wales & Australian Capital Territory Unit B, Egerton Street, Silverwater, New South Wales, 2128 T: F: E: info.nsw@ampac.net Northern Territory 2/10 Cato St, Winnellie, Northern Territory, 0820 T: F: E: info.nt@ampac.net Queensland 1/53 Parramatta Road, Underwood, Queensland, 4119 T: F: E: info.qld@ampac.net South Australia 63 Grange Road, Welland, South Australia, 5007 T: F: E: info.sa@ampac.net Victoria & Tasmania 345 Darebin Road, Thornbury, Victoria, 3071 T: F: E: info.vic@ampac.net As part of Ampac s commitment to continuous improvement, specifications may change without notice. Version 15/09/15

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-9

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-9 EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-9 TABLE OF CONTENTS Section Page No. 1 About This Manual... 3 1.1 Introduction... 3 1.2 References...

More information

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-5

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-5 EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-5 MAN2995-2 05/09/12 TABLE OF CONTENTS Section Page No. 1 About This Manual... 3 1.1 Introduction...

More information

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1 SmartTerminal AS7240 Installation and Operation Guide MAN2990-1 Table of Contents Page No. 1 Introduction... 3 2 Mechanical... 4 2.1 Mounting the Enclosure... 4 2.1.1 Enclosure Details... 4 2.1.2 Fixing

More information

OPERATION AND INSTALLATION MANUAL

OPERATION AND INSTALLATION MANUAL EX+Plus 2 ZONE, 1AREA EXTINGUISHANT CONTROL PANEL OPERATION AND INSTALLATION MANUAL INTRODUCTION The Premier EX Plus is a 2 zone, single area panel for controlling the release of extinguishing gases in

More information

Solution F2. Fire Alarm Control Panels one step ahead.

Solution F2. Fire Alarm Control Panels one step ahead. Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution

More information

Fire Alarm Control Panel Installation, Commissioning & Operation MAN

Fire Alarm Control Panel Installation, Commissioning & Operation MAN DH4 ZoneSense Fire Alarm Control Panel Installation, Commissioning & Operation MAN 1531-5 Access Level 1 (Normal Operation) Responding To An Alarm Zone FIRE Alarm Indicator - flashing Common FIRE Alarm

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

4 wire conventional alarm system

4 wire conventional alarm system Scimitar 4 wire conventional alarm system from Channel Safety Systems Scimitar 4 wire conventional alarm system The Scimitar Fire Alarm Control System is a comprehensive range of high specification conventional

More information

System 800 Addressable Fire Detection & Alarm System

System 800 Addressable Fire Detection & Alarm System SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools

More information

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options

More information

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System DIVA8MG2 Public Address - Voice Alarm Audio Distribution over IP Commercial Audio Intelligent Acoustic Solutions Intercommunication Loudspeakers Compact PAVA System Master Unit DIVA8 System DIVA8 system

More information

The EN54 Part 2 & 4 Fire System

The EN54 Part 2 & 4 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices. FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001

More information

ECC-50/100C. Emergency Command Center

ECC-50/100C. Emergency Command Center ECC-50/100C Emergency Command Center Canadian DF-60815:B Emergency Communications General Fire-lite s ECC-50/100C is a multipurpose emergency voice evacuation panel for fire applications, mass notification

More information

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range Fire Detection MINERVA Marine MX T2000 Panel Range Features: Enhances fire detection and eliminates unwanted alarms using fuzzy logic Assists fire fighting and training by providing on-screen risk management

More information

Vigilant MX4428 Fire Alarm System

Vigilant MX4428 Fire Alarm System Vigilant MX4428 Fire Alarm System The Vigilant MX4428 is an intelligent fire alarm system, incorporating Tyco MX TECHNOLOGY to provide advanced, analogue addressable fire detection. It features support

More information

Analogue addressable devices

Analogue addressable devices Apollo XP95 Analogue addressable devices from Channel Safety Systems Apollo XP95 Analogue addressable devices The XP95 range of analogue addressable fire detectors is advanced in design, improved in performance

More information

FireFinder PLUS. Fire Alarm Control Panel (AS & 4 / AS4428-3) Installation, Commissioning & Operation MAN2994-6

FireFinder PLUS. Fire Alarm Control Panel (AS & 4 / AS4428-3) Installation, Commissioning & Operation MAN2994-6 FireFinder PLUS Fire Alarm Control Panel (AS7240 2 & 4 / AS4428-3) Installation, Commissioning & Operation MAN2994-6 FIRE BRIGADE FIRE BRIGADE RESPONSE RESPONSE GUIDE GUIDE Responding to a Fire Access

More information

ZXSe Range Data Sheet

ZXSe Range Data Sheet ZXSe Range Data Sheet Analogue addressable fire alarm control panel Product Overview The ZXSe range of analogue addressable fire alarm control panels have been designed and constructed around proven and

More information

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum

More information

The EN54 Part 2, 4 and 13 Fire System

The EN54 Part 2, 4 and 13 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

Elemec3. Networked Public Address and General Alarm System (PA/GA)

Elemec3. Networked Public Address and General Alarm System (PA/GA) Elemec3 Networked Public Address and General Alarm System (PA/GA) Multiple combined single, N+1 and A/B architectures supported on a single network Seamless connection to and from VoIP telephones, amplified

More information

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS ECC-50/100(E) Emergency Command Center DF-60734:A4 General Firelite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd full installation, commissioning and operating manuals can be downloaded from www.haes-systems.co.uk combined addressable / conventional fire alarm control panel User Guide Approved Document No. MFBU-04

More information

MX4428. Addressable Fire Alarm System. Features. Advantages & Options

MX4428. Addressable Fire Alarm System. Features. Advantages & Options MX4428 Addressable Fire Alarm System Features // Supports MX Series devices including the 850 Series Generation 6 Multi-Sensor analogue addressable detector range // SMARTSENSE and MX FASTLOGIC (fuzzy

More information

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features Fire Safety ZXSe Range Analogue addressable fire alarm control panel The ZXSe range of analogue addressable fire alarm control panels have been designed and constructed around proven and reliable microprocessor

More information

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description MODUL-R FIRE ALARM CONTROL PANELS MR-2900/MR-2920 Addressable Fire Alarm Control Panels Description MR-2900 Fire Alarm Control Panel The MR-2900 fire alarm system control unit is the heart of a sophisticated

More information

Conventional Fire Alarm System 2014 V1.2

Conventional Fire Alarm System 2014 V1.2 Conventional Fire Alarm System 2014 V1.2 Product Overview Control Panel 2 Conventional Fire Panel GST102A 2 zone Fire panel GST104A 4 zone Fire panel GST108A 8 zone Fire panel GST116A 16 zone Fire Panel

More information

FIRE BRIGADE RESPONSE GUIDE. LoopSense. Fire Alarm Control Panel (AS4428 & AS & 4) Operation & Onsite Programming MAN

FIRE BRIGADE RESPONSE GUIDE. LoopSense. Fire Alarm Control Panel (AS4428 & AS & 4) Operation & Onsite Programming MAN LOOPSENSE FIRE BRIGADE RESPONSE GUIDE LoopSense Fire Alarm Control Panel (AS4428 & AS7240. 2 & 4) Operation & Onsite Programming MAN 1567-2 LOOPSENSE FIRE BRIGADE RESPONSE GUIDE Responding to a Fire Access

More information

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection The Hart XL High Sensitivity Smoke Detection system (HSSD) is an aspirating fire detection system designed to give very early indication of an incipient fire condition.

More information

GAI-Tronics Systems NEW! Elemec3 Digitally Controlled PA and General Alarm system PA/GA

GAI-Tronics Systems NEW! Elemec3 Digitally Controlled PA and General Alarm system PA/GA The Elemec3 is a digitally controlled Public Address and General Alarm (PA/GA) system. Designed principally for life critical installations in the Oil and Gas market, it is also suitable for many industrial

More information

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel Application Guide Contents Page 1.0 Introduction and Typical System Illustration 2 2.0 Cabinet Specifications 4 3.0 Hardware

More information

Vocia VACIE. Reference Guide

Vocia VACIE. Reference Guide Vocia VACIE Reference Guide Document Revision 1.2.3, August 2015 Biamp Systems 9300 SW Gemini Drive Beaverton, Oregon 97008, U.S.A. (503) 641-7287 www.biamp.com INTRODUCTION... 3 SECTION 1... 4 VACIE CONFIGURATION...

More information

ID3000 intelligent. fire alarm panel

ID3000 intelligent. fire alarm panel ID3000 intelligent fire alarm panel features introduction certified to EN54 parts 2 and 4 The NOTIFIER ID3000 intelligent fire alarm panel offers a technically sophisticated range of facilities and functions

More information

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 ANALOGUE FIRE DETECTION VIGILON COMPACT FEATURES & BENEFITS four Keep it Simple All Vigilon devices connect onto the same 2

More information

On the job around the clock 24/7: Fire detection systems

On the job around the clock 24/7: Fire detection systems On the job around the clock 24/7: Fire detection systems Version 02.2010 Version: 02.2010 Product catalogue Fire detection systems This product catalogue is intended for sales purposes only. For planning,

More information

Microphones VIGIL VIGIL. Unitouch. combined data sheets LEADING THE WAY TO SAFETY

Microphones VIGIL VIGIL. Unitouch. combined data sheets LEADING THE WAY TO SAFETY VIGIL Microphones VIGIL Unitouch combined data sheets LEADING THE WAY TO SAFETY Emergency Fire Microphone Certified to BSEN54 BFM400 is a range of fully monitored emergency fire microphones that provide

More information

Conventional Fire Detection

Conventional Fire Detection SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct

More information

ID3000 intelligent. fire alarm panel

ID3000 intelligent. fire alarm panel ID3000 intelligent fire alarm panel features certified to EN54 parts 2 and 4 expandable from 2 to 8 loop capacity up to 198 per loop (99 sensor and 99 modules) 255 fire zones per panel modular design supports

More information

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS DCA4 Digitally controlled Audio Matrix Product Specification March 2002 Current Thinking Document Number DDC DCA 7001 01 ACS Introduction Voice Alarm (VA) systems are the quickest way to evacuate the public

More information

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology Fire-Cryer Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX Shaping Alarm Technology Fire-Cryer Plus The Fire-Cryer range of voice sounders was first introduced to the market by Vimpex in 1999.

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd THE NANO SYSTEM The revolutionary analogue addressable control panel Nano, the revolutionary control panel from Gent Nano is the latest fire detection control panel from Gent by Honeywell. It s a single

More information

Addressable and Conventional Fire Protection

Addressable and Conventional Fire Protection Addressable and Conventional Fire Protection Simply reliable F I R E P R O T E C T I O N The MAGPro and Fireline systems has been created to balance performance, reliability and aesthetics whilst being

More information

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features 990-052, Issue 6 20 March 2006 ID50 Series Single Loop Intelligent Fire Alarm Panels Section: Intelligent Fire Alarm Panels GENERAL The NOTIFIER ID50 series single loop intelligent fire alarm panels, has

More information

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL Document No...G108WO1.DOC Serial No... Issue Date...17 th SEPTEMBER 1999 Software Version...1.4 APPROVED TO: NZS 4512:1997 AS/NZS 3548:1992 Fire Alarm

More information

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Intelligent 2 & 4 Loop Fire Alarm Control Panels Intelligent 2 & 4 Loop Fire Alarm Control Panels Advanced has combined the latest technology with many years of fire experience, to create the Axis AX Series Intelligent Fire Alarm Control Panels. The

More information

Touch Screen 1 loop Addressable Fire Alarm Panel

Touch Screen 1 loop Addressable Fire Alarm Panel evolution 1 Touch Screen 1 loop Addressable Fire Alarm Panel The evolution 1 control panel offers complete compatibility with the award winning range of Nittan evolution detection and alarm devices and

More information

SmartTerminal. Installation Commissioning & Operation. Our aim is to provide Consistently Excellent Service in the eyes of our customers MAN1536-6

SmartTerminal. Installation Commissioning & Operation. Our aim is to provide Consistently Excellent Service in the eyes of our customers MAN1536-6 WORLD LEADER OF INNOVATIVE SOLUTIONS IN FIRE DETECTION AND ALARM SYSTEMS SmartTerminal AS4428 FireFinder Installation Commissioning & Operation Our aim is to provide Consistently Excellent Service in the

More information

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM Integrated Voice Evacuation System VM-3000 series Emergency Voice Alarm System Incorporating Digital Audio PA, Paging and BGM High-quality, compact public

More information

VACIE REFERENCE GUIDE REVISION 1.2.6

VACIE REFERENCE GUIDE REVISION 1.2.6 VACIE REFERENCE GUIDE REVISION 1.2.6 November 2016 INTRODUCTION... 3 SECTION 1... 4 VACIE CONFIGURATION... 4 Communications... 4 Vocia VACIE Devices... 4 Vocia Support devices:... 5 Power Supply and Network

More information

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi (P/N 10-068) is a state-of-the-art true intelligent digital peer-topeer modular suppression control system. It is ideal for

More information

Intelligent Single Loop Fire Alarm Control Panel

Intelligent Single Loop Fire Alarm Control Panel Intelligent Single Loop Fire Alarm Control Panel The CAX-CTL-1L Intelligent Single Loop Fire Alarm Control Panel is a member of the industry leading Axis AX Series Intelligent Fre Alarm Control Panels

More information

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi 50 (P/N 10-071) is a state-of-the-art true intelligent digital peer-to-peer modular suppression control system.

More information

ConfigManager PLUS. Fire Alarm Control Panel MAN Programming Software for FireFinder PLUS

ConfigManager PLUS. Fire Alarm Control Panel MAN Programming Software for FireFinder PLUS ConfigManager PLUS Programming Software for FireFinder PLUS Fire Alarm Control Panel MAN 3016-3 Section TABLE OF CONTENTS Page No. 1 About This Manual... 1 1.1 Introduction... 1 1.2 General Requirements...

More information

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL 26 Aug 2015 V1.8 Page 1 SECTION CONTENTS PAGE NO. 1.0 SYSTEMS DESCRIPTION 1.1 General descriptions 2 1.2 Master Alarm PCB 2 1.3 Zone Display Board 2 1.4

More information

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel Application Guide Contents Page 1.0 Introduction and Typical System Illustration 2 2.0 Cabinet Specifications 4 3.0 Hardware

More information

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable Protec Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE Protec Protec Algo-TecTM 6100 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL

More information

Consultant Specification AGILE Wireless Fire Detection System

Consultant Specification AGILE Wireless Fire Detection System Contents Scope of Work... 2 The EN54 Part 2 & 4 Fire System... 2 Standards... 2 Wireless Intelligent Photoelectric Smoke Detector Specification... 4 Wireless Intelligent Thermal Heat Detector Specification...

More information

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL Fire Alarm Control Panel & MANUAL CONTENTS SECTION -. Description of the fire control panel fascia.... Alarm.... Reset the system.... Sound and silence the alarms.... Read the Fire, Fault, Test and Disabled

More information

Excel-EN Conventional Fire Control Panel

Excel-EN Conventional Fire Control Panel Available as 2, 4, 6, 8,10 or 12 zones Approved to EN54-2 & 4 Modular expansion zone cards Programmable relays and outputs Optional additional sounder circuits Optional additional programmable outputs

More information

Advanced FireAlarm Panel 1-4Loop

Advanced FireAlarm Panel 1-4Loop Advanced FireAlarm Panel 1-4Loop Advanced Technologies Advanced Electronics Ltd IP Gateway Monitoring and interrogation via the internet Password protected multiple user permissions Event notification

More information

SP40S-D. Kingfisher Company, inc. Features: Description:

SP40S-D. Kingfisher Company, inc. Features: Description: Kingfisher Company, inc. SP40S-D Features: Multi-use applications The system can function as an evacuation system, an emergency messaging system, and an employee notification system Fire code applications

More information

Fire and Gas Monitoring Panel ST7-HV

Fire and Gas Monitoring Panel ST7-HV Fire and Gas Monitoring Panel ST7-HV INTRODUCTION TO THE ST7-HV SYSTEM The ST7-HV system is a programmable PLC suitable for safety and security installations with a high technological and economic content

More information

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R Region Project Page 1 PART 1 - GENERAL 1.1 REFERENCES.1 CAN/ULC-S524-2006, Standard for the Installation of Fire Alarm Systems..2 CAN/ULC-S525-2007, Audible Signal Device for Fire Alarm Systems..3 CAN/ULC-S526-2007,

More information

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING GENERAL The VEC 25/50 is a state-of-the-art, compact, stand-alone or slave Emergency Voice Evacuation Control. The VEC 25/50 is offered in a self-contained, cost-effective design and includes a 25 Watt,

More information

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR ED820 24V MODEL fire DETECTOR INSTRUCTION MANUAL Address: Enigma House, Enigma Business Park, Malvern, Worcestershire, WR14 1GD Tel: 44 (0)1684 891500 Fax: 44 (0)1684 891600 Email: sales@electronicdevices.co.uk

More information

INTELLIGENT FIRE ALARM CONTROL PANEL

INTELLIGENT FIRE ALARM CONTROL PANEL INTELLIGENT FIRE ALARM CONTROL PANEL FX-2000 SERIES Description Mircom s FX-2000 Series Intelligent Analog Fire Alarm Control Panel is designed to provide maximum flexibility of analog system requirements

More information

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual Syncro AS Analogue Addressable Fire Control Panel User Manual Man-1100 Issue 02 Nov. 2008 Index Section Page 1. Introduction...3 2. Safety...3 3. Panel Controls...4 3.1 Access Level 1...4 3.2 Access Level

More information

July 14, 1999 DF C-100.

July 14, 1999 DF C-100. www.firelite.com GENERAL The Fire Lite FIRE COMMAND 25/50 is a state-of-theart, compact, stand-alone or slave Emergency Voice Evacuation Control Panel (VECP). The FIRE COMMAND 25/50 is offered in a self-contained,

More information

Fire Alarm. Control. Panel - 3)

Fire Alarm. Control. Panel - 3) FireFinder PLUS Fire Alarm Control Panel (AS7240 2 & 4 / AS4428-3) Installation, Commissioning & Operation MAN2994-4 FIRE BRIGADE FIRE BRIGADE RESPONSR ESPONSE SE GUIDE GUIDE Responding to a Fire Access

More information

DCS-100. intelligent damper control & monitoring system

DCS-100. intelligent damper control & monitoring system DCS-100 intelligent damper control & monitoring system 02 //DCS-100 Introduction The Disys Technologies DCS-100 is a revolutionary new control system designed specifically for the fire/smoke damper controls

More information

Fire Alarm Control Panel EN54 2 & Operation & Programming MAN

Fire Alarm Control Panel EN54 2 & Operation & Programming MAN ZoneSense PLUS Fire Alarm Control Panel EN54 2 & 4 1997 Operation & Programming MAN 2374-10 Responding to an Alarm 1. Indicators FIRE FIRE ZONE 1 ZONE 2 FAULT/DISABLED/ Z2 ZONE SEVEN Common Fire Indicator

More information

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM Description Mircom s FleX-Net TM Series Network Fire Alarm Control Panels offer modular components to meet a wide variety of applications. Designed for peerto-peer

More information

Fire control panel detect 3004 plus and accessories

Fire control panel detect 3004 plus and accessories Fire control panel detect 3004 and accessories The modular fire alarm panel detect 3004 is the basic version of a broad product portfolio of the system detect 3000. Up to 20 fire control panels can be

More information

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable Protec Protec Fire Detection Pty Ltd Fire Detection - Addressable Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE Fire Detection

More information

ECC-50/100(E) Emergency Command Center

ECC-50/100(E) Emergency Command Center ECC-50/100(E) Emergency Command Center DF-60734:A9 C-200 General Fire Lite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,

More information

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel ACC-25/50ZST Zoned System Voice with Telephone Evacuation Control Panel General The AUDIO COMMAND CENTER 25/50 Zone System with FireFighters Telephone (ACC-25/50ZST) is a state-of-the-art Emergency Voice

More information

XP95/Series 90 Test Set

XP95/Series 90 Test Set PP1072/2003/Issue 5 XP95/Series 90 Test Set XP95/SERIES 90 TEST SET BIT 0 BIT 1 BIT 2 NEW TEST MIN/MAX DOWN * UP # LOOP POWER OFF ON OUTPUT HEALTHY LOOP + - User Manual 1 Apollo XP95/Series 90 Test Set

More information

Sita200plus. 200detectors. Single loop analogue addressable System

Sita200plus. 200detectors. Single loop analogue addressable System Single loop analogue addressable System Fast short circuit isolator in every device 15 combinations of smoke & heat detection modes Loop length up to 2km long with spurs INTELLIGENT FIRE TECHNOLOGY A D

More information

ZoneSense PLUS. Fire Alarm Control Panel (AS4428.1) Operation & Programming MAN

ZoneSense PLUS. Fire Alarm Control Panel (AS4428.1) Operation & Programming MAN ZoneSense PLUS Fire Alarm Control Panel (AS4428.1) Operation & Programming MAN 1564-2 Table of Contents SECTION... Page No Responding to an Alarm... 1 1 Introduction... 2 2 Controls Front Panel... 2 2.1

More information

16 Zone Voice Evacuation VA & PA Sound System

16 Zone Voice Evacuation VA & PA Sound System 16 Zone Voice Evacuation VA & PA Sound System 4 Channel Main Amp VA-MP4120 PC Server & Software VA-2000ST T-565 Zone 1-4 One Channel Standby Amp VA-2000RM VA-2000MA T-565 Zone 5-8 LAN CAT5 Cable CAT5 Data

More information

ID2000. intelligent fire alarm panel

ID2000. intelligent fire alarm panel ID2000 6pp A4 10-01 3/8/06 22:57 Page 1 ID2000 intelligent fire alarm panel features Certified to EN54 Parts 2 and 4 Expandable from 2 to 8 loop capacity Up to 198 devices per loop (99 sensor and 99 modules)

More information

TrueAlarm Fire Alarm Controls

TrueAlarm Fire Alarm Controls FIRE ALARM ALARMS S DISABLEMENT DISABLED ZONES SITE SPECIFIC PROGRAMMABLE KEYS/LEDS S /DISABLED SILENCED DISABLE/ENABLE S SILENCE/RESOUND SYSTEM PULL DOOR TO OPEN RESET PANEL SILENCE POWER INDICATION OF

More information

Solution F1. Fire Control Panels the new generation

Solution F1. Fire Control Panels the new generation Solution F1 Fire Control Panels the new generation Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F1 The Concept The Solution F1 Fire Control Panel range is a new

More information

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS) Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS) INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0)

More information

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring GE Security FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring Version v2-2 / September 2005 Aritech and Kilsen are GE Security brands. http://www.geindustrial.com/ge-interlogix/emea

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection Hart XL High Sensitivity Smoke Detection (HSSD) TM is a smoke detection system that is simple to install, commission, service and use yet remains brilliantly capable in

More information

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER Application The unit is primarily intended for use where there is a requirement to integrate a limited fire protection function into a larger control equipment scheme, or in specialist applications where

More information

I-2000 INSTALLATION, OPERATION & COMMISSIONING MANUAL. 20/10/2009 Rev: 5.00

I-2000 INSTALLATION, OPERATION & COMMISSIONING MANUAL. 20/10/2009 Rev: 5.00 I-2000 INSTALLATION, OPERATION & COMMISSIONING MANUAL 20/10/2009 Rev: 5.00 DOC-01-016 ECN09-092 Documentation Feedback Your feedback helps us keep our documentation up to date and accurate. If you have

More information

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

ZIOU/230 - MAINS IO INSTRUCTION MANUAL Description ZIOU/230 - MAINS IO INSTRUCTION MANUAL The Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third party equipment with the Fire Alarm Control panel

More information

Emergi-Lite Orbis detectors

Emergi-Lite Orbis detectors Emergi-Lite Orbis detectors Emergi-Lite Orbis brings the latest in fire detector microprocessor technology to the Firetec and Eurofire systems. Non-addressable (conventional) smoke and heat sensors respond

More information

Call stations and extensions

Call stations and extensions Novigo Call stations and extensions PT2001-A1, PT2002-A1, PT2008-A1, PT2009-A1, PTO2001-A1, PTO2002-A1, PTO2003-A1, PTO2004-A1, PTO2005-A1, PTO2006-A1, PTO2008-A1 EN 54-16-certified alarm and business

More information

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable Protec Fire Detection - Addressable Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE Fire Detection - Addressable Protec Protec Algo-TecTM

More information

Saxon Range 1-8 Zone Convertional Control Panels

Saxon Range 1-8 Zone Convertional Control Panels Tel: 00448450751042 Fax: 00448450751043 Email: info@fireguarduk.com 2nd FLOOR 145157 ST.JOHNS STREET LONDON EC1V 4PY UNITED KINGDOM 18 Zone Convertional Control Panels Key Features Builtin detector removal

More information

An introduction to... Sigma

An introduction to... Sigma An introduction to... Sigma XT+ Sigma XT+ Overview The Sigma XT+ 21000 series are the latest additions to the Sigma family of control equipment from Kentec Electronics Limited. The Sigma XT+ range combines

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems OPERATOR OPERATOR OR TROUBLE CONDITION: TO : FIRE PRIORITY 2SYSTEM SYSTEM SIGNALS POWER INDICATOR. SUPERVISORYTROUBLE SILENCED ON D. TO SILENCE SIGNALS: - PRESS " SILENCE". SUPV TBL SYSTEM ACK ACK ACK

More information

IGD.CO.UK

IGD.CO.UK APPLICATION DATA SHEET S p e c i f i c a t i o n 2 SO22 WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700+ D e t e c t o r Website: C o n t r o l P a n e l - Wall mounting or 19 Rack

More information

Addressable Fire Alarm Control Panel

Addressable Fire Alarm Control Panel PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT

More information