INSTALLATIONN GUIDE & OPERATION MANUAL

Size: px
Start display at page:

Download "INSTALLATIONN GUIDE & OPERATION MANUAL"

Transcription

1 INSTALLATION INSTRUCTIONS ECO # 1569 REVISION #0006 FCS SERIES MODEL 5025, 5045,7525 & 7545 INSTALLATION INSTRUCTIONS BY: DATE: 01/23/2013 INSTALLATIONN GUIDE & OPERATION MANUAL MOTOR OPERATOR (V3.02 Controls) FCS SERIES MODEL 5045 & /2 HP & FCS SERIES MODEL 7545 & /4 HP FCS SERIES, U.S. GEAR COVERED UNDER US PATENTS #6,900,602, #7,055,283 AND ADDITIONAL PATENTS PENDING The Cookson Company, Inc 2417 S. 50 TH Avenue Phoenix, Arizona Phone: (602) Fax: (866) Page 1 of 30

2 TABLE OF CONTENTS I. GENERAL NOTES... 3 II. SPECIFICATIONS... 3 III. INSTALLATION INSTRUCTIONS 1. Installation Positions Control Installation A. Control Box Mounting... 5 B. Wiring Procedure for Operator and Control Panel... 7 C. Wiring Push Button or Key Switch Limit Switch Adjustment Lead Post Wiring Instructions... A. Precautions B. Procedure Check List Wiring Diagrams Field Wiring Terminal Strip Connections Functions Table Output Warnings Sound Warnings Light Indication Switch Indication Function and Timer Set-Up Instruction.26 IV. OPERATING INSTRUCTIONS V. MAINTENANCE INSTRUCTIONS Page 2 of 30

3 I. GENERAL NOTES To reduce the risk of severe injury or death, read and follow all installation instructions. The operator must be installed by qualified door mechanics using proper tools and equipment. Make sure the available power supply to be connected to the operator is of the same voltage, frequency and phase as indicated on the nameplate of the control panel. Read and understand the manual before installing the operator. Read and understand the wiring diagram of the operator, control station and any other equipment to be connected to the operator. Always disconnect power when installing or servicing the door operator or door. All wiring is to comply with National Electrical Code (NEC) and local code requirements. Any change in mounting position may result in change of operator rotation and consequently in change of control functions. Consult factory for any changes. II. SPECIFICATIONS (1/2 HP) (3/4 HP) INPUT FCS 5045 FCS 5025 FCS 7545 FCS 7525 Voltage 120VAC 208~240VAC 120VAC 208~240VAC Phase Frequency 60 Hz 50/60 Hz 60 Hz 50/60 Hz Full Load Current 5.5 amps 2.75 amps 6 amps 3 amps Wire Gauge 14 AWG 14 AWG 14 AWG 14 AWG (1/2 HP) (3/4 HP) MOTOR FCS 5045 FCS 5025 FCS 7545 FCS 7525 Horsepower 1/2 1/2 3/4 3/4 Voltage 24VDC 24VDC 24VDC 24VDC Current 13 amps 13 amps 17 amps 17 amps RPM Gear Ratio 43:1 43:1 43:1 43:1 Output RPM Door Speed 6 or 9 in/sec 6 or 9 in/sec 6 or 9 in/sec 6 or 9 in/sec Sprocket Size 6 in/sec: 18T 6 in/sec: 18T 6 in/sec: 18T 6 in/sec: 18T 9 in/sec: 28T 9 in/sec: 28T 9 in/sec: 28T 9 in/sec: 28T Drive Chain #40 #40 #40 #40 Duty 10 cycles/hour 10 cycles/hour 10 cycles/hour 10 cycles/hour Rating ft-lb./sec (1680 in-lb./sec) 140 ft-lb./sec (1680 in-lb./sec) 180 ft-lb./sec (2160 in-lb./sec) 180 ft-lb./sec (2160 in-lb./sec) Brake Solenoid Actuated Solenoid Actuated Solenoid Actuated Solenoid Actuated Battery (2) 12V 17.2AH (2) 12V 17.2AH (2) 12V 17.2AH (2) 12V 17.2AH Wiring Diagram or above or above EP 107 A EP 107 A V3.02 (230) V Ratings tested at the output shaft. or above EP 307 A V3.02 or above EP 307 A (230) V3.02 ENTRAPMENT PROTECTION Sensing Edge Sensing device attached to the leading edge of the door Exit Bars Exit hardware positioned on each side of door to allow emergency exit. Page 3 of 30

4 III. INSTALLATION INSTRUCTIONS 1. Installation Positions Operator: Operators are shipped as a complete unit and are fastened directly to the header using the provided lag screws. Drill 1/4 pilot holes prior to installing the lag screws. A template that calls out the proper pilot hole locations will be provided with the operator. Operator should be installed on the centerline of the header and butted up against the back wall of the pocket. Install (2) bolts into the pilot holes drilled at the back of the header. Leave 1/2 space between the header and the head of the lag bolt. Slide the operator onto the lag bolts making sure the operator is butted up against the back wall of the pocket. Hold the operator in place by installing (2) # 10 track screws through the 1/4 holes located at the front of the motor bracket flange. Retrieve the remaining lag bolts and complete the operator installation by tightening all (4) lag bolts into the header. HEADER SLOTTED HOLES TOWARD POCKET WALL BACK WALL OF POCKET Figure 1.a. Installing Operator. Page 4 of 30

5 2. Control Installation A. Control Box Mounting Locate and unpack the control box marked Box A. The Control Box should be installed on the back wall of the pocket using the appropriate fasteners based on the wall construction (not provided by Cookson). See Figure 2.a. The bottom of the Control Box should at least 24 from the finished floor to provide ample room for any junction boxes and wiring. Use the measurements provided in Figure 2.a and Figure 2.b to mark the required hole locations. Partially insert the top (2) fasteners, leaving approximately 1/4 between the back wall of the header and the fastener head. Position the Control Box mounts over the installed fasteners via the large area of the keyhole. Slide operator to control down so that the fasteners are positioned in the narrow, top portion of the keyhole. Tighten the fasteners. Insert fasteners in the narrow, top portion of the keyholes on the bottom (2) mounts. Figure 2.a. Installed Control Box. Figure 2.b. Control Box Hole Locations. Page 5 of 30

6 CONTROL BOX TO BE SURFACE MOUNTED AT THE BACK OF THE POCKET 24" MIN. FROM THE FLOOR BY COOKSON DOOR INSTALLER. DC MOTOR DRIVE UNIT (BOX B) A FOLDING FIRE DOOR BY COOKSON CONTROL BOX (BOX A) FLEX CONDUIT 12" 24" MIN. SECTION THRU A A NOTE: ALL ELECTRICAL COMPONENTS TO BE INSTALLED IN ACCORDANCE WITH LOCAL BUILDING CODE REQUIREMENTS. ALARM INPUT WIRING AND CONDUIT BY ELECTRICAL CONTRACTOR. 4" X 4" "J" BOXES SURFACE MOUNTED 12" ABOVE THE FINISHED FLOOR BY ELECTRICAL CONTRACTOR. CONDUIT FROM SURFACE MOUNTED "J" BOX TO THE SWITCH WITH 4 CONDUCTOR LOW VOLTAGE STRANDED HOOK-UP WIRE. 22GA. MIN, 14GA. MAX BY ELECTRICAL CONTRACTOR. PUSH BUTTON BY COOKSON. SUPPLY WIRING INTO "J" BOX WIRING AND CONDUIT BY ELECTRICAL CONTRACTOR. Figure 2.c. Installed Operator and Control Box Page 6 of 30

7 Figure 2.d. Control Panel Door Latch NEC Compliance Upgrades To comply with the requirements for electrical installations per the National electric code, Kontrol Fire operator control panels are provided with a plunger switch that turns off power to the motor operator, and the 24VDC system at exposed terminals, as soon as the control panel door is opened beyond its latched position. The input power wire terminals are covered and labeled to disconnect power before removing cover. The DC battery terminals are also covered to limit contact with the 24 volt terminals and a fuse cover is provided for added protection. This setup is designed to prevent access to live wires within the control panel when the control box door is open. B. Wiring Procedure for Operator and Control Panel 1. For BOX (A) Main Control Panel connections to Motor Operator BOX(B) A separate circuit is recommended for the operator. The flexible cable provided with the Main Control Panel contains all the wires that must be connected to the Motor Operator. Connections are already made in the Main Control Panel. Attach flexible cable to Box (B). Field connections required at the Motor Operator are clearly marked on the terminal block end of all wires. Page 7 of 30

8 FCS-5045, FCS-7545 BATTERY SPECIFICATION (12VDC 17.2AH*2) Figure 2.e. Battery Diagram 2. For BOX (A) Battery Enclosure 1 BAT1(-) BAT2(+) 2 BAT1(+) QC1(+) 3 BAT2(-) QC1(-) (QC= red quick connect plug) 3. Connections required at Motor Operator BOX (B): See Figure 2.f. DC Motor Connections located on page 9 and 10. Page 8 of 30

9 Figure 2.f. DC Motor Connections Limit Switch (LS) Limit Switch (LS) Page 9 of 30

10 Limit Switch (LS) Limit Switch (LS) Page 10 of 30

11 C. Wiring Push Button or Key Switch Push button supplied as standard by Cookson. Key Switch option is available. 1. If possible, position the push button or key switch such that the door is visible while operating 2. See Figure 2.g. for wiring information. (Continuous Mode shown.) PUSH BUTTON OR KEY SWITCH SINGLE BUTTON MULTIPLE STATIO OPE 2 OPE OPE 3 CLOS 3 CLOS CLOS 4 STO 4 STO STO Figure 2.g. Control Station Wiring Diagram *REMOVE JUMPER CONNECTING MORE THEN UNITS 3. Limit Switch Adjustment To avoid serious injury or death, disconnect power before manually moving limit switch cams. Make sure the open and close limit cams are positioned between the limit switch actuators before proceeding with adjustments. Refer to Figure 3.a. 1. The operator is factory set so that the limit switch is bypassed in order to prevent possible damage when threading the chain. Before setting the limits, remove the screw shown in Figure 3.b in order to engage the limit switch assembly. 2. Make sure main power supply is turned off and batteries are unplugged. The clutch will not be engaged. You will be able to manually move the lead post trolley by pushing it. 3. Move the lead post toward the striker (Closing direction). Note the movement of the white limit cams. They will be moving toward the close limit switches. 4. Single Slide Doors: Position the lead member trolley so the front of the trolley is 3 1/2 inches from the back of the striker. Refer to Figure 3.c. Bi-Parting Doors: Position the lead member trolleys so the front of each trolley is 2 1/2 inches from the marked center point of the header. Refer to Figure 3.d. Page 11 of 30

12 5. Set the close limit by depressing the spring-loaded locking bar (G). Rotate the white limit cam closest to the close limit until it trips the bottom switch on the close limit side. Release the locking bar (G) and make sure the upturned lip is engaged in a slot on each limit cam. This insures that your setting is maintained. 6. Manually move the lead post trolley into the pocket. The white limit cam will be moving toward the open limits. 7. Position the lead post trolley in the pocket area so the front of the trolley is 6 inches behind the front of the pocket (or front of the pocket door). Refer to Figure 3.e. 8. Repeat Step 5 of the Initial Limit Switch Adjustment to set the open limit. 9. This completes the initial limit switch setting. Final adjustments be required after installation of door is complete. Note that each notch on the limit switch cam will change the door position by approximately 3/8 inch. 10. Test control and operator before installing curtain. 11. Once initial limits are set, refer back to Section 6. Door Section Install of the Door Installation Guide once the initial limits are set. E G F A C Figure 3.a. Limit Switch Adjustment D B Figure 3.b. Limit Switch Bypass Screw NOTE: (A/C) is normally the OPEN limit switch and (B/D) is normally the CLOSE limit switch. 2 1/2 2 1/2 CENTER POINT Figure 3.c. Single-Slide Closed Limit (Bottom View) Figure 3.d. Bi-Part Closed Limit (Bottom View) Page 12 of 30

13 Figure 3e. Open Limit Position (Bottom View) 4. Lead Post Wiring Instructions Disconnect power at the fuse box and the operator before proceeding with any wiring. A. Precautions 1. Do not install any wiring or attempt to run this operator without checking the wiring diagram located on the inside of the control box cover. 2. Do not turn on power until you have finished making all power and control wiring connections. 3. Any wire connecting to the control panel must be protected by conduit or other means to ensure the safety and permanency of the wiring. 4. Use copper wire inside the control panel. 5. The operator must be properly grounded. The ground screw, plated green, is located inside the control panel. B. Procedure Failure to properly ground the operator could result in electric shock and serious injury or death. 1. Do not run control wiring in the same conduit as power wiring. 2. After installation, be sure that the operator, controls, and sensing edge or other entrapment protection devices have been tested and function properly. 3. Refer to Single-Slide doors: Figure 4a. Bi-Part Single Operator: Figure 4b. Bi-Part Dual Operator: Figure 4c. Page 13 of 30

14 ON LEAD MEMBER : : Figure 4a. Lead Post Wiring Diagram (Single-Slide Doors) ON LEAD MEMBER : : Figure 4b. Lead Post Wiring Diagram (Single Operator Bi-Parting Doors) Page 14 of 30

15 ??? :? : Figure 4c. Lead Post Wiring Diagram (Dual Operator Bi-Parting Doors) Page 15 of 30

16 5. Check List Make sure all wires are connected, supply power is OFF, disconnect the battery wires. Make sure Alarm Wires are connected. TB3 termination 11 & 12 normally closed for dry contact. Set Open and Close limits and position the door at the close limit before connecting alarm wires. Jump High Limit connection, TB3 (16 & 17). Adjust Emergency Opening Distance (if required) Standard door speed is 9 inches per second. Timer setup to increases opening travel. Adds 9 of egress opening for each second on the timer. Factory Default: Approximately 54. Refer to Section 13. Function and timer set-up (5) Egress Exit Open timer on page 27. Check that Battery wires are connected and correct. Connect 120VAC main power. Page 16 of 30

17 6. Wiring Diagram Page 17 of 30

18 Page 18 of 30

19 Page 19 of 30

20 Figure 6.a. Model FCS Wiring Diagram Page 20 of 30

21 7. Field Wiring Terminal Strip Connections TB AC power warning dry contact, 24VAC/DC, 0.5A Max. Contact open when abnormal Overload warning dry contact, 24VAC/DC, 0.5A Max. Contact open when abnormal. Battery voltage warning dry contact, 24VAC/DC, 0.5A Max. Contact open when abnormal. LH-Open limit RH-Close limit dry contact, 24VAC/DC, 0.5A Max. Contact open when door reaches limit. LH-Close limit RH-Open limit dry contact, 24VAC/DC, 0.5A Max. Contact open when door reaches limit. Charge warning dry contact, 24VAC/DC, 0.5A Max. Contact open when abnormal. High Temp or Alarm or Overload dry contact, 24VAC/DC, 0.5A Max. Contact open when abnormal. TB A Control Station Key Switch or 3-button control station Sensing edge connection N/O. (End of line resistor) Egress bar connections. Dry contact Alarm connection. High limit (Jump when not connected to high limit). Stop Open Close Com Note: 1. When using Key Switch without a stop button, terminals 1 & 4 should be jumped and ONLY select constant pressure close and open. 2. CN7 Force Open Warning Dry Contact contact points will be opened when door was pushed away from close limit and failed to reach close limit position within 5 seconds Power Output 24VDC/1A Max. Power output when Alarm condition. Page 21 of 30

22 8. Functions Table Item Function Normal Condition Alarm Condition 1 Control Station TB3 (1,2,3,4) Sensing Edge TB3 (5 & 6) (See section 13, (13) and (14) Exit Direction [(Exit Bar Connection TB3 (7, 8A or (blank)] (Only label 7 & 8 A, and a blank) High Temperature Limit TB3 (16 & 17) Clutch Always Engage at Opening setting (Logic setting) (See Section 13, (11)) Fire door selection (S106) (F.D. & E.D. Switch) (E.D. Selected) FD Fire Door without Exit Bar ED Fire Door with Exit Bar Battery Warning Closing (S104) (Stay Open & Close 2 Feet Switch) Constant Pressure OPEN and CLOSE Door will CLOSE. Constant pressure OPEN but auto closing. Sensing edge will reverse door travel for 3 seconds and then door will close again. If the 3 Sec. reverse and then stop obstruction is not removed, the door will stop on the obstruction on the 3 rd closing Sensing Edge can be inactive during the initial closing. This inactive distance can be adjusted. Sensing Edge is inactive during last few inches of door closing. This inactive distance can be adjusted. When Sensing Edge is engaged, Exit Hardware and push button station will be active. All exit bars are functional. No effect of the door operation. Select (NO) to disengage clutch when door is in the open position. This can prolong battery life during power failure. No effect on regular operation of the door. If selected (Close 2 Feet), when door is in the open limit position, it will automatically CLOSE 24 inches during battery low. This is to notify the user that the battery needs to be checked. This is in addition to normal sound and signal outputs. The clutch will be disengaged when the door is in the closed 2 position due to the low battery. If selected (Stay Open), normal sound and signal outputs will apply. Battery Needs to be checked Exit direction will dictate which exit bar will be functional. 7 & 8A-active during both normal and alarm condition. 7 & (blank) -active only during normal condition, not alarm condition. All three conditions have to be met to disable the opening function of the door: alarm condition, door close condition, and high limit break. If selected (F.D.), no exit bar will be functional. When door reaches close limit, all control function will cease per NFPA Control function is back to normal only after alarm condition has been cleared. If E. D. selected.), exit bar will be functional. Battery Low sound and signal outputs continue to happen after the door has closed during alarm. Clutch will be engaged during alarm condition. Page 22 of 30

23 Functions Table (Continued) Item Function Normal Condition Alarm Condition 8 Exit Bar Setting (S105) (Switch: ON Setting) (Logic setting) (See Section 13, (6)) If selected (ON), door will OPEN to preset distance, pause and then CLOSE. Pause time can be adjusted between 3-99 seconds via Logic Setting. If not selected (OFF), door will OPEN to preset time/distance and stop. Door will OPEN to preset distance, pause and then CLOSE. Pause time is the same as normal condition Exit Bar Opening (6-99 seconds). (Logic Setting) (See Section 13, (5)) Security Door Option (Switch: E.D. Mode) Security Mode : select Yes (Logic setting) (See Section 13, (3)) Can increase the opening time/distance of Exit Bar. Minimum time is 6 seconds, which will provide approximately 54 inches of opening. Maximum distance is to open limit. Factory default is 6 seconds. Exit Bar will not be functional. Door can only be opened or closed via push-button control station or key switch. Exit Bar will be functional. 11 Security Door Power Loss of AC Power (Switch: E.D. Mode) Auto Close : select Yes In Security Mode (See Section 13, (4)) If both Security Door Option and Security Door Power are selected (YES), door will automatically CLOSE during power failure and Exit Bar will be functional. If selected (NO), then only Security Door Option is active. Door will not CLOSE during power failure. Door will auto CLOSE due to alarm and Exit Bar will be active. 12 Alarm Delay Time (Logic setting) (See Section 13, (7)) No effect on normal operation. Select 0~10 second delay, but alarm warning power/signal is present as soon as alarm condition happens. This allows pre-warning before door starts closing Clock (Logic setting) (See Section 13, (8)) Battery load test time and setting (Logic setting) (See Section 13, (9)) Alarm Restore Auto Open (Logic setting) (See Section 13, (12)) No effect in operation. Not necessary to specify. If a specific time is needed, need to set clock. No affect in operation. When alarm clears door will auto open. Page 23 of 30

24 9. Output Warnings Item Terminals Description Contact Type 1 35 & 36 AC Power Warning Dry Contact 2 37 & 38 Overload Warning Dry Contact 3 39 & 40 Battery Voltage Warning Dry Contact 4 41 & & 44 LH-Open Limit RH-Close Limit LH-Close Limit RH-Open Limit Dry Contact Dry Contact 6 45 & 46 Charge Warning Dry Contact 7 47 & 48 High Temp or Alarm or Overload Dry Contact 8 49 & 50 Power Output 24VDC 9 CN7 Warning Output Dry Contact 10. Sound Warnings Item Description Sound A AC power loss warning signal B B.B. B B.B. B B.B.. B Overload warning signal B B. B B. B B. C Battery failure warning signal B B.B.B. B B.B.B. B B.B.B.. D E Alarm warning signal or high temperature T1,4 not connected or control panel cover opened B B B B B.B.B.B. B.B.B.B. B.B.B.B.. Page 24 of 30

25 11. Light Indication Light Function Color ON OFF R LED1 Brake Red Activated Not Activated Y LED2 Clutch Yellow Activated Not Activated R LED3 AC Failure Red Normal Abnormal R LED4 Overload Red Normal Abnormal R LED5 Battery Failure Red Normal Abnormal R LED6 Aux. Open Limit Contact Red Not at open limit Door reached open (T41&42 output) R LED7 Aux. Close Limit Contact Red Not at close limit Door reached close (T43&44 output) R LED8 Charge Voltage Failure Red Normal Abnormal R LED9 MCU Failure Red Normal Abnormal R LED10 Alarm Power Output Red Abnormal Normal R LED11 High Limit or Alarm or OL Red Normal Abnormal G LED100 Input Power Green Normal Abnormal 12. Switch Indication S106 F.D. E.D. S105 S104 Fire door or Egress door selection ON OFF Egress Bar setting Stay Open Close 2 Feet Battery Low door status S108 LH RH R side or L side selection F.D : Fire door. E.D : Egress door. ON : Auto close. OFF : Non- auto close. Stay open. Close 2 Feet. RH : R side. LH : L side.. Page 25 of 30

26 13. Function and Timer Set-Up Instructions (1) Standby Mode: AC Power Counter AC 000V DC 00.0V CNT: :06 Battery Power Current Time (2) Constant/Momentary pressure setting of OPEN/CLOSE Button Press SET for three seconds to enter setting mode. Use SELECT to choose Constant Pressure. Use + and - to Constant Pressure or Momentary Pressure. Press SET again to save setting. SAVE SUCCESS will appear if setting is complete. >Constant Pressure Momentary Pressure Constant Pressure Choose Constant Pressure >Momentary Pressure Momentary Pressure (3) Security Mode setting in Exit Door Mode Switch to E.D. Mode, Press SET for three seconds to enter setting mode. Use SELECT to choose Security Mode. Use + and - to Yes or No. Press SET again to save setting. SAVE SUCCESS will appear if setting is complete. Attention: F.D. mode is not for security mode setting. Security Mode Select:Yes Security Mode (4) Door Close setting in AC Power loss Switch to E.D. Mode, Press SET for three seconds to enter setting mode. Use SELECT to choose Loss of AC Power Auto close. Use + and - to Yes or No. Press SET again to save setting. SAVE SUCCESS will appear if setting is complete. Attention: F.D. mode is not for door close setting in AC Power loss. Loss of AC Power Auto Close:Yes Loss of AC Power Page 26 of 30

27 (5) Egress Exit Open timer Press SET for three seconds to enter setting mode. Use SELECT to choose Egress open time. Use + and - to set time: 06~99, 06 being the minimum time for 54 inches of opening. Press SET again to save setting. SAVE SUCCESS will appear if setting is complete. Egress open time:06 (06 99) 00: NO use Egress open time:06 (6) Egress Pause Timer: Press SET for three seconds to enter setting mode. Use SELECT to choose Egress pause close. Use + and - to set time: 03~99, 03 being the minimum time for egress pause close. Press SET again to save setting. SAVE SUCCESS will appear if setting is complete. Egress pause close:03 (03 99) 00: NO use Egress pause close:03 (7) Alarm Delay Time Press SET for three seconds to enter setting mode. Use SELECT to choose Alarm delay time. Use + and - to set time: 00~10, 00 being disabled. Press SET again to save setting. SAVE SUCCESS will appear if setting is complete. Alarm delay time:00 (00 10) 00:NO use Alarm delay time:00 (8) Clock Press SET for three seconds to enter setting mode. Use SELECT to choose Clock-Set time. Use + and - to set hour. (00~24 hour) Press SELECT again to set minute. Use + and - to set minute. (00~59 minutes) Press SET again to save setting. SAVE SUCCESS will appear if setting is complete. Clock-Set time 10:00 HOUR(00 23) :10 Clock-Set time 10:10 MINUTE(00 59):10 Clock-Set time 10:10 Page 27 of 30

28 (9) Battery load test time and setting: (Every 24 hours and 10 second of load test.) Press SET for three seconds to enter setting. Use SELECT to choose Battery test time. Use + and - to set hour. (00~23 Hours) Press SET again to save setting. SAVE SUCCESS will appear if setting is complete. Battery test time HOUR(00 23):23 Battery test time (10) Loss AC Warning Press SET for three seconds to enter setting mode. Use SELECT to choose Loss AC delay. Use + and - to set time: 00~180 minutes, 00 being disabled. Press SET again to save setting. SAVE SUCCESS will appear if setting is complete. Loss AC delay:000 (00 180) 00:NO Delay Loss AC delay:000 (11) Clutch Always Engage At Opening setting Press SET for three seconds to enter setting mode. Use SELECT to choose Clutch Always Engage At Opening. Use + and - to set time: YES or NO. Press SET again to save setting. SAVE SUCCESS will appear if setting is complete. Clutch Always Engage At Opening : Yes Clutch Always Engage (12) Alarm Restore Auto Open Press SET for three seconds to enter setting mode. Use SELECT to choose Alm Restore AutoOpen. Use + and - to set Yes or No. Press SET again to save setting. SAVE SUCCESS will appear if setting is complete. Alm Restore AutoOpen (Yes or No) : Yes Alm Restore AutoOpen Page 28 of 30

29 (13) SE OFF Delay Sensing edge disable delay when LS4 engaged Press SET for three seconds to enter setting mode. Use SELECT to choose SE OFF Delay. Use + and - to set time: 0~5 seconds for SE OFF Delay from LS4 engaged. Press SET again to save setting. SAVE SUCCESS will appear if setting is complete. SE OFF Delay (0 5) sec: 0.0 SE OFF Delay (14) SE ON Delay Sensing edge enable delay when LS3 disengaged Press SET for three seconds to enter setting mode. Use SELECT to choose SE ON Delay. Use + and - to set time: 0~5 seconds for SE ON Delay from LS3 disengaged. Press SET again to save setting. SAVE SUCCESS will appear if setting is complete. SE ON Delay (0 5) sec: 0.0 SE ON Delay (15) Alarm Warning Sound Press SET for three seconds to enter setting mode. Use SELECT to choose Alarm Warning Sound. Use + and - to set Yes or No. Press SET again to save setting. SAVE SUCCESS will appear if setting is complete. Alarm Warning Sound (Yes or No) : No Alarm Warning Sound (16) High TEMP Sound Press SET for three seconds to enter setting mode. Use SELECT to choose High TEMP Sound. Use + and - to set Yes or No. Press SET again to save setting. SAVE SUCCESS will appear if setting is complete. High TEMP Sound (Yes or No) : Yes High TEMP Sound Page 29 of 30

30 IV. OPERATING INSTRUCTIONS Three Button Control Station Action Response Press OPEN Door should open Press CLOSE Door should close Press STOP while holding Door should stop either OPEN or CLOSE Removing pressure from Door should stop CLOSE during motion Key Switch Control Station Action Response Turn key to OPEN Door should open Turn key to CLOSE Door should close Press STOP while holding Door should stop key on OPEN or CLOSE Removing key from CLOSE Door should stop position during motion Note: All power AC & DC needs to be turned off to the operator before manually operating the door. V. MAINTENANCE INSTRUCTIONS Disconnect power supply to the operator before servicing. Do not place hands or tools in or near the operator when the power is connected or when testing control or safety devices. Always disconnect power before adjusting the operator. The brake is a self-adjusting brake. It is maintenance free. The brake assembly requires no additional adjustments for its lifetime. Do not lubricate motor. Lubrication could cause damage. Inspect and service whenever a malfunction of either door or operator is observed or suspected. Before servicing, always disconnect power supply to the operator. Replace fuses only with those of the same type and rating. All replacement parts must be compatible with those originally provided. Page 30 of 30

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL. FT-EPB Series. Single Motor

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL. FT-EPB Series. Single Motor INSTALLATION INSTRUCTIONS AND OPERATION MANUAL AlarmGard Fire Door Operator FT-5EPB / FT-50EPB Single Motor IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the risk of death or serious injury to

More information

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL. FST-EPB Series. Single Motor

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL. FST-EPB Series. Single Motor INSTALLATION INSTRUCTIONS AND OPERATION MANUAL AlarmGard Fire Door Operator FST-5EPB / FST-50EPB (v4) Single Motor IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the risk of death or serious injury

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D2 MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D2 GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F II 1400-2 ACSI 1406-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F INSTALLATION Transformer Model BE31763001 by Basler Electric, Transformer Model 2010028 by Galaxy

More information

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA) INSTRUCTION MANUAL AlarmGard Chain Operator (Model FCA) & AlarmGard Crank Operator (Model FKA) WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within

More information

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual prior to installing and/or servicing this product. As with all releasing device

More information

SP-1000X. Panic Device Power Controller Installation Guide. Rev

SP-1000X. Panic Device Power Controller Installation Guide. Rev TM SP-1000X Panic Device Power Controller Installation Guide Rev. 120213 Overview: SP-1000X will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed to handle the high current

More information

MANUAL RESET ALARM RELEASE BOX

MANUAL RESET ALARM RELEASE BOX MANUAL RESET ALARM RELEASE BOX (For 100~240VAC or 24VAC or 24VDC) INSTRUCTION MANUAL WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

Series. Access Power Controllers. Installation Guide

Series. Access Power Controllers. Installation Guide Series Access Power Controllers Installation Guide Models Include: Maxim11 - Power Supply 1: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Power Supply 2: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Sixteen (16) fuse

More information

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC. M Series Multi-Output Access Control Power Supply Chargers Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 3 amp @ 12VDC or 4 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp

More information

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

SOLID STATE SECURITIES, INC. THE SS90 SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL S S S S S S LISTED L * PATENT PENDING S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT U 99Y9 RESET RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev RPSMLR2 RPSMLR2BB Panic Device Power Controller Installation Guide LISTED Rev. 102715 Overview: RPSMLR2BB, RPSMLR2 will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed

More information

INSTALLATION & MAINTENANCE CORNELL FIREGARD CHAIN & ES ECO #1515 REVISION # 0000 FIREGARD CRANK OPERATORS BY: RICKM DATE: 3/23/2011

INSTALLATION & MAINTENANCE CORNELL FIREGARD CHAIN & ES ECO #1515 REVISION # 0000 FIREGARD CRANK OPERATORS BY: RICKM DATE: 3/23/2011 INSTALLATION & MAINTENANCE CORNELL FIREGARD CHAIN & ES 10-343 ECO #1515 REVISION # 0000 FIREGARD CRANK OPERATORS BY: RICKM DATE: 3/23/2011 INSTRUCTION MANUAL FireGard Chain Operator (Model FCF) & FireGard

More information

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION: RELEASE DEVICES MADE IN THE U.S.A. RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: The "WPS" World Power Series, Time Delay Release

More information

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL Firefly II Multi Voltage RELEASE DEVICES Firefly II & IIB-MV INSTALLATION MANUAL GENERAL DESCRIPTION: S/N The The Cookson Company Firefly II-MV time delay release devices are designed for use on rolling

More information

Installation Guide for models:

Installation Guide for models: 140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal3FD - 12VDC @ 4.6 amp or 24VDC @ 5.2 amp. - Sixteen (16) PTC protected power-limited outputs.

More information

OWNER S MANUAL MODEL FDCL C

OWNER S MANUAL MODEL FDCL C OWNER S MANUAL MODEL FDCL C LMPLC CONTROL LMPLC CONTROL WIRED ADVANCED LOGIC INDUSTRIAL DUTY FIRE DOOR OPERATOR 2 YEAR WARRANTY NOT FOR RESIDENTIAL USE Serial # Box (located on electrical box cover) Installation

More information

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC. M Series Multi-Output Access Control Power Supply Charger Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 4 amp @ 12VDC or 3 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp @

More information

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev Installation Guide for AL600ULM Multi-Output Access Control Power Supply Charger Rev. 091800 1 AL600ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL600ULM multi-output access control

More information

Installation Guide for models:

Installation Guide for models: 140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal11F - Power Supply 1: 12VDC @ 3.3 amp or 24VDC @ 3.6 amp. - Power Supply 2: 12VDC @ 3.3 amp

More information

Hand Chain (Model FCF) &

Hand Chain (Model FCF) & Hand Chain (Model FCF) & Hand Crank (Model FKF) INSTRUCTION MANUAL 0 WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual prior to installing

More information

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE Cookson 100 Elmwood Avenue Crestwood Industrial Park Mountaintop, PA 18707 Phone: 800-233-8366 Fax: 800-526-0841 CornellCookson.com O W N E R S M A N U A L M O D E L S F I R E G A R D M C F I R E G A R

More information

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES POWER SUPPLY AND BATTERY CHARGER AC AND DC STATUS INDICATORS ENOUGH POWER TO SUPPORT UP TO 3 MAGLOCKS OR ELECTRIC STRIKES PLUS REQUIRED

More information

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL RELEASE DEVICES MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL The LiftMaster Fire Control (LM21-AFC) Release Device/Control Panel is UL/CUL listed normally energized fail-safe device incorporating

More information

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger Installation Guide for AL300ULM Multi-Output Access Control Power Supply Charger R AL300ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL300ULM multi-output access control power supply/charger

More information

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector Wiring Instructions for the 900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector CAUTION: FAILURE TO INSTALL OR ADJUST PROPERLY MAY RESULT IN INJURY OR

More information

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-3 ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS Features: For use with doors or groups of doors that must interlock with each other to regulate control of accessing one area from another,

More information

AUTO RESET ALARM RELEASE BOX MODEL AR-C INSTRUCTION MANUAL

AUTO RESET ALARM RELEASE BOX MODEL AR-C INSTRUCTION MANUAL AUTO RESET ALARM RELEASE BOX MODEL AR-C INSTRUCTION MANUAL AR C Rev.06 WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual prior to

More information

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs ACM Series Access Power Controllers with Power Supplies Installation Guide Models Include: AL400ULACM AL600ULACM - 12VDC @ 4 amp - 12VDC or 24VDC @ 6 amp. or 24VDC @ 3 amp - Fused Outputs - Fused Outputs

More information

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep. Power Supply/Chargers Installation Guide Models Include: eflow4na8d - 4A @ 12VDC or 24VDC - Eight (8) PTC Outputs eflow6na8d - 4A @ 12VDC or 24VDC - Eight (8) PTC Outputs eflow102na8d - 10A @ 12VDC - Eight

More information

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone: Cookson Company 1901 South Litchfield Road Goodyear, AZ 85338 Phone: 800-294-4358 www.cooksondoor.com O W N E R S M A N U A L MODEL FIREFLY III EXTENDED PERFORMANCE RELEASE DEVICE TABLE OF CONTENTS INTRODUCTION

More information

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep. Power Supply/Chargers Installation Guide Models Include: eflow4na8-4a @ 12VDC or 24VDC - Eight (8) Fused Outputs eflow6na8-4a @ 12VDC or 24VDC - Eight (8) Fused Outputs eflow102na8-10a @ 12VDC - Eight

More information

LMPLC OWNER S MANUAL MODEL FDC. B2 Wiring ADVANCED LOGIC INDUSTRIAL DUTY FIRE DOOR OPERATOR 2 YEAR WARRANTY LMPLC CONTROL US PATENT NO.

LMPLC OWNER S MANUAL MODEL FDC. B2 Wiring ADVANCED LOGIC INDUSTRIAL DUTY FIRE DOOR OPERATOR 2 YEAR WARRANTY LMPLC CONTROL US PATENT NO. OWNER S MANUAL MODEL FDC ADVANCED LOGIC INDUSTRIAL DUTY FIRE DOOR OPERATOR US PATENT NO. 6,0,307 LMPLC CONTROL LMPLC CONTROL WIRED B Wiring YEAR WARRANTY Serial # (located on electrical box cover) NOT

More information

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information: RDM LOCK G-1 1400 Series Electromagnetic Lock The patented 1400 Series Electromagnetic Lock is universal for all types of applications, including outdoor use. The innovative design will reduce installation

More information

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

SS90 SERIES CONTROLS MODEL C INSTALLATION MANUAL S S S SS O L I D S S90 TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED U L 99Y9 RESET RELEASING DEVICE SOLID STATE SECURITIES, INC. "SS90" SERIES CONTROLS MADE IN THE U.S.A. MODEL

More information

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com LiftMaster 300 Windsor Drive Oak Brook, IL 60523 LiftMaster.com O W N E R S M A N U A L MODELS LM21AFCB LM21AFCBVB B ADVANCE FIRE CONTROL RELEASE DEVICE FM APPROVED TABLE OF CONTENTS INTRODUCTION General

More information

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger Installation Guide for AL400ULM Multi-Output Access Control Power Supply Charger R AL400ULM - Multi-Output Access Control Power Supply/Charger Rev. 072500 Overview: The AL400ULM multi-output access control

More information

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

THE SS90 SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL S S S S S S OLID TATE ECURITIES, INC S S 90 SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED 99Y9 RESET U L RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL MADE IN THE U.S.A. U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION SERIAL NUMBER The Cookson Company FIREFLY II PLUS Time Delay Release

More information

Rack Mount Series Installation Guide

Rack Mount Series Installation Guide Rack Mount Series Installation Guide Models Include: Maximal1RHV Maximal1RV - 12VDC @ 4 amp or 24VDC @ 3 amp. - 12VDC @ 4 amp or 24VDC @ 3 amp. - Eight (8) Fuse Protected Outputs. - Sixteen (16) Fuse Protected

More information

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual ITC 2000 HEATING CONTROL CABINET Installation & Operation Manual VTI, Incorporated 24 McMillan Way Newark, DE 19713 Phone (302) 738 0500 FAX (302) 738 6594 Revision Level 0.03 Manual No. 90003314 June,

More information

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C) The Norseman Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions. Norseman unit heaters are available

More information

Los Angeles Abrasion Machine HM-70A & HM-70AF

Los Angeles Abrasion Machine HM-70A & HM-70AF Operating Manual Los Angeles Abrasion Machine HM-70A & HM-70AF Rev: 07/24/2018 PHONE: 800-444-1508 740-548-7298 P.O. Box 200, Lewis Center, Ohio 43035-0200 E-mail: customerservice@gilsonco.com Website:

More information

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction Riser and Point-to-Point Drawings for Standard Access Control Applications Using Maintained Latch Retraction Control or Momentary

More information

Emergency Lighting Transfer System Model: ELTS2 Installation and User Operation Manual

Emergency Lighting Transfer System Model: ELTS2 Installation and User Operation Manual Emergency Lighting Transfer System Model: ELTS2 Installation and User Operation Manual Part Number: 1096M1200 Rev: E Released: 2018-07 ETC is a registered trademark of Electronic Theatre Controls, Inc.

More information

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER JOCKEY PUMP CONTROLLER Model JPCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page 4 Model

More information

Explosion-Proof Forced Air Unit Heater - XGB

Explosion-Proof Forced Air Unit Heater - XGB Explosion-Proof Forced Air Unit Heater - XGB The XGB Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions.

More information

RANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts.

RANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts. BAKE ELEMENT RANGE BAKE ELEMENT ADMIRAL AMANA CALORIC GLENWOOD HARDWICK IMPERIAL MAGIC CHEF MAYTAG WHIRLPOOL ROPER SUNRAY WELBILT 308180 2600/1950 Watts 240/208 Volts.250 male terminal push-in connection

More information

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01 PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Warnings and Notices WARNING - To reduce the risk of fire or electric shock, do not expose this product

More information

MODEL 6430T, 6460 & 6460T POTATO PEELER

MODEL 6430T, 6460 & 6460T POTATO PEELER MODEL 6430T, 6460 & 6460T POTATO PEELER MODEL ML-137602 6430T ML-19630 6460 ML-137604 6460T ML-104562 6460C ML-137606 6460CT 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 37005 (Apr. 2006) Installation,

More information

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

THE SS90 SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL S S S S S S S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED U 99Y9 RESET L RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

OPERATING MANUAL. Los Angeles Abrasion Machine. PHONE: FAX: Website:

OPERATING MANUAL. Los Angeles Abrasion Machine. PHONE: FAX: Website: OPERATING MANUAL Los Angeles Abrasion Machine Rev: 07/19/2012 PHONE: 800-940-1928 FAX: 800-863-1573 E-mail: service@certifiedmtp.com Website: www.certifiedmtp.com SAFETY INSTRUCTIONS Whether you are the

More information

Explosion-Proof Forced Air Unit Heater - XGB

Explosion-Proof Forced Air Unit Heater - XGB Explosion-Proof Forced Air Unit Heater - XGB The XGB Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions.

More information

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps TT-1023 1/97 INSTALLATION INSTRUCTIONS Original Issue Date: 2/94 Model: 6-2000 kw Market: Industrial Subject: Flush- or Surface-Mount Remote Annunciator Kits PA-293991 and PA-293991-SD The remote annunciator

More information

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations: F1! 44487023 These instructions cover the following parts: PS902 Power Supply Installation Instructions! DANGER: To avoid risk of electric shock, turn off AC power before installing or servicing PS902

More information

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR SECTION 08734 COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES A. Overhead

More information

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep. 140 58th St. Brooklyn, NY Power Supply/Chargers Installation Guide Models Include: eflow4n/eflow4nx - 4 amp @ 12VDC or 24VDC eflow4n8/eflow4nx8 eflow4n8d/eflow4nx8d - 4 amp @ 12VDC or 24VDC - 4 amp @ 12VDC

More information

VIKING RANGE CORPORATION, P.O. DRAWER 956, GREENWOOD,MS USA

VIKING RANGE CORPORATION, P.O. DRAWER 956, GREENWOOD,MS USA VIKING RANGE CORPORATION, P.O. DRAWER 956, GREENWOOD,MS 38930 USA TABLE OF CONTENTS VDSC ( Dual fuel ) / VESC (Electric) RANGES / VERT (Rangetop) COMPONENTS AND FUNCTIONAL PARTS: Control / Timer ------------------------------------------------------------------------------------------------------

More information

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC SECTION 08 35 13.23 ACCORDION FOLDING FIRE DOORS PART 1 GENERAL 1.01 SUMMARY OF WORK A. Division 0 and 1, as indexed, apply to this section. B. Furnish and install

More information

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117 Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel Revision E 61117 CAUTION: (Read This First) This panel has been designed to make it nearly bullet proof to mistakes made when wiring

More information

M O D E L S FIREGARD BV EXTENDED PERFORMANCE RELEASE DEVICE

M O D E L S FIREGARD BV EXTENDED PERFORMANCE RELEASE DEVICE Cornell 100 Elmwood Ave. Crestwood Industrial Park Mountaintop, PA 18707 tel 800.233.8366 fax 800.526.0841 cornell@cornelliron.com O W N E R S M A N U A L M O D E L S F I R E G A R D B B FIREGARD BV EXTENDED

More information

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits CommStat 4 PRODUCT DATA SHEET Controller for Redundant Telecom HVAC Systems General Description The CommStat 4 is an HVAC controller designed specifically for controlling two redundant air conditioners,

More information

Booster Power Supply Manual

Booster Power Supply Manual Supply Manual DEVELOPED BY COPYRIGHT NOTICE General Signal Building Systems Corporation 6411 Parkland Drive Sarasota, FL 34243 (941) 739-4300 Copyright 1999 General Signal Building Systems Corporation

More information

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER PRESSRE MAINTANENCE CONTROLLER Models PMCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page

More information

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE SAFE A N D SECURE Cornell 100 Elmwood Ave. Crestwood Industrial Park Mountaintop, PA 18707 Tel 800.233.8366 Fax 800.526.0841 Email: cornell@cornelliron.com O W N E R S M A N U A L M O D E L F I R E G A

More information

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE D (OPERATION) INITIATE A DYNAMIC BATTERY TEST The system tests the back-up battery once every 24 hours. The owner can initiate a dynamic battery test at any time with the following codes while the system

More information

CHECK NEW PRODUCTS SECTION FOR NEW INNOVATIVE SOLUTIONS

CHECK NEW PRODUCTS SECTION FOR NEW INNOVATIVE SOLUTIONS CHECK NEW PRODUCTS SECTION FOR NEW INNOVATIVE SOLUTIONS Table of Contents - Electronic Access & Releasing Devices Pushbutton Access Release Devices................ H1-H8 620/631 Series Heavy Duty Pushbuttons

More information

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK Installation Manual AQM-20 12vdc/24vdc Series Power Supplies AQM20 Supervised Power Supply/Charger 12vdc 20Amp/24vdc 10Amp Life Time Warranty Quality Manufactured in the USA AQM20 Features: The AQM20 has

More information

Installation, Operation, and Maintenance Information

Installation, Operation, and Maintenance Information Installation, Operation, and Maintenance Information Low Velocity Unit Coolers Bulletin No. IOM 110.3 Table of Contents Inspection... 2 Installation... 2 4 General... 2 Location... 2 Drain Line... 3 Refrigerant

More information

MODEL B2 INSTALLATION MANUAL

MODEL B2 INSTALLATION MANUAL RELEASE DEVICES GENERAL DESCRIPTION MODEL B2 INSTALLATION MANUAL S/N: The B2 Series Time Delay Release Devices are UL Listed, Canadian Listed, and CSFM Listed for use on rolling doors, single-slide and

More information

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: These Time Delay Release Devices are U.L. Listed, Canadian Listed,

More information

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS Specifications subject to change without notice. USA 150303 Page 1 of 10 MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS Specifications subject to change without notice.

More information

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S. ValkyrieTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you

More information

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. Irene 52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz TABLE OF CONTENTS Tools and Materials Required... 1 Package Contents... 1 Safety Rules... 2 Mounting Options... 3 Hanging

More information

FLCH4R Garage and Utility Electric Heater

FLCH4R Garage and Utility Electric Heater FLCH4R Garage and Utility Electric Heater Installation, Operation & Maintenance Instructions Model No. Volts Amps Watts BTU/HR Phase High Low High Low High Low Min Fuse Size* FLCH4R 208 17.3 8.66 3600

More information

Econo-Coat RCM 8000 Powder Spray Booth Installation Guide

Econo-Coat RCM 8000 Powder Spray Booth Installation Guide Installation Guide P/N 1028657A Econo-Coat RCM 8000 Powder Spray Booth Installation Guide WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this

More information

HI Industrial Utility Heater HI Soleus Air International

HI Industrial Utility Heater HI Soleus Air International HI1-50-03 Industrial Utility Heater HI1-50-03 2010 Soleus Air International Thank you for choosing a Soleus Air Utility Heater. This owner s manual will provide you with valuable information necessary

More information

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL Crypto-Lock Model CC-8521B Updated 7/17 Access Control System INSTRUCTION MANUAL MONITEQ, Inc. 2 TABLE OF CONTENTS 1. INTRODUCTION..4 2. SPECIFICATIONS.....6 3. SUPPLIED EQUIPMENT.. 6 4. FUNCTIONS OF CONTROLS

More information

Public Safety DAS Annunciator Panel

Public Safety DAS Annunciator Panel Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This

More information

DE5300 Delayed Egress System. General Information

DE5300 Delayed Egress System. General Information *911031-00* 911031-00 Wiring and Configuration DE5300 Delayed Egress System Installation Instructions General Information The Von Duprin DE5300 is designed for controlled egress applications when used

More information

CommStat 4 Controller

CommStat 4 Controller CommStat 4 Controller CommStat 4 Telecom HVAC Controller The CommStat 4 is an HVAC controller designed specifically for controlling two redundant air conditioners, heat pumps and air conditioners with

More information

/ How To Order

/ How To Order 84-800 / 85-800 How To Order SERIES 84 = 1.0A continuous (powers and controls 1 EExER device with signal output for 1 operator) 85 = 2.0A continuous (powers and controls EExER device for 1 pair of doors

More information

Remote Chexit Module (RCM) System. General Information

Remote Chexit Module (RCM) System. General Information *911032-00* 911032-00 Wiring and Configuration Remote Chexit Module (RCM) System Installation Instructions General Information The Von Duprin RCM is designed for controlled egress applications. It meets

More information

ELITE SERIES INDUSTRIAL AC SLIDE GATE OPERATOR

ELITE SERIES INDUSTRIAL AC SLIDE GATE OPERATOR ELITE SERIES INDUSTRIAL AC SLIDE GATE OPERATOR INSTALLATION MANUAL Model SL585UL SL585101UL 1 HP, 120/208-240 Vac Single Phase SL585103UL 1 HP, 208-240/480 Vac Three Phase SL585105UL 1 HP, 575 Vac Three

More information

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS RV Products Division INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330C755 CONTROL BOX KIT (12 VDC HEAT READY) 8530-750 CONTROL BOX KIT

More information

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S. Patent Pending Orrin A Kichler Select ceiling fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010

More information

WARNING Important Safety Information

WARNING Important Safety Information Builder Series Non-Programmable Thermostats MODEL 1000 MODEL 0 1 2 3 4 Single Stage Heat / Cool Conventional and Heat Pump Multi-Stage 2 Heat / 1 Cool Conventional and Heat Pump Before Installing, Programming

More information

Installation and Operation Manual Low Power (LP) DC Power System

Installation and Operation Manual Low Power (LP) DC Power System Installation and Operation Manual Low Power (LP) DC Power System LPS Power Enclosure LPB Battery Enclosure 2051259 R3 Information in this document is subject to change without notice and does not represent

More information

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description Worldwide Contacts www.tyco-fire.com VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description The TYCO VIZOR Electronic Dry Pipe Accelerator (EDPA) is

More information

Feed Table FT42. Operator s Manual

Feed Table FT42. Operator s Manual Feed Table FT42 Operator s Manual Belshaw Bros., Inc. 814 44 th Street NW, Suite 103 Auburn, WA 98001 USA Phone: +-1-206-322-5474 Fax: +-1-206-322-5425 E-mail: service@belshaw.com http://www.belshaw.com

More information

Power Locking Installation Manual

Power Locking Installation Manual Shop Manual V203 Please Copy Necessary Pages, and Store the Original Power Locking System PLRB-Pro Controller Flex Switch & Key Fobs Numeric Keyless Interface Power lock (Compartments) Power Locking Installation

More information

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS INDEECO Circulation Heaters are designed to provide years of trouble free operation if properly installed and maintained. Please read and follow these instructions for installing and maintaining the heater.

More information

MODEL /4" Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload

MODEL /4 Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload 2900 FIREGUARD Electromechanical Closer-Holder Device Models 12-2960, 9-2960 and 2960 Multipoint Hold Open with Rigid Arms Pull (Hinge) Side Installation Instructions CAUTION: FAILURE TO INSTALL OR ADJUST

More information

INTRODUCTION / TABLE OF CONTENTS

INTRODUCTION / TABLE OF CONTENTS 1 2 INTRODUCTION / TABLE OF CONTENTS Step One The LVCN 20 and LVCN 100 Series are general purpose level controllers offered in two configurations for pump and valve control. The LVCN 100 Series features

More information

Modular Fillerplate Subassembly P/N: X Endcap P/N: Strike *, P/N: " Narrow Stile Plastic Template. Mortise.

Modular Fillerplate Subassembly P/N: X Endcap P/N: Strike *, P/N:  Narrow Stile Plastic Template. Mortise. 103182 June 3, 2010 Delayed Egress Parts Check List V40 EM Centercase/Pushpad Modular SubAssembly P/N: 104374-X Plastic Template Use for ease of installation P/N: 103806-X Detex Corporation, 302 Detex

More information

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door CAUTION Hinge Edge of Door Wiring Instructions Checkmate Series with Single Point Hold-Open Combination Door Closer-Holder and Releasing Device with or without Integral Smoke Detector INSTALLER: LEAVE

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit PRODUCT INSTRUCTIONS Fire Door Control Panel (FDCP) Floats Rd, Wythenshawe, Manchester. M23 9WB T: 44 (0)161 945 4561 F: 44 (0)161 945 4566 Stock Code Description Doc No: PI115 00133 00134 Ellard Fire

More information

WARNING Important Safety Information

WARNING Important Safety Information 1 Specifications Premier Series Non-Programmable Thermostats MODEL 3000 MODEL 3200 1 2 3 4 5 Specifications Installation Testing Your New Thermostat Programming User Settings Temperature Adjustment WARNING

More information