Quick Selection Guide Fire Systems LSN Periphery

Size: px
Start display at page:

Download "Quick Selection Guide Fire Systems LSN Periphery"

Transcription

1 Local SecurityNetwork Easy wiring Auto configuration capability (self-learning mode) Central programming of all device configurations from the panel Flexible network structure (Loop, stub, T-tap & mixed structure) All cable types usable (Shielded & Unshielded cables) Reduced programming and installation cost and time No special cable types needed, existing cables can be used Up to 3000 m line length Up to 1.5 A current Up to 254 elements per loop/line Up to 127 elements per loop/line in LSN classic Less installation time and cost through reduced number of loops Increased number of loop powered devices Built-in diagnosis functions Remote support is possible Easy and cost efficient maintenance and support Short circuit isolators in each device increase system integrity and cost savings One cable connects multiple areas Can withstand a short or open circuit at any point in the loop and all devices still function Digital communication into every detector High security against tamper Addressable detectors Automatic or manual address setting possible Easy operation Way of address setting can be chosen depending on wiring One bus for intrusion, fire and malfunction Cost efficient installation, additional security Remote programming and maintenance Cost efficient and time saving Special features LSN improved

2 FAH-T 420 Heat Detector Combination of rate of rise and fixed temperature measurement FAP-O 420 Optical Light scattering principle FAP-DO 420 Dual-Optical Smoke Detector Dual Ray technology - Two light scattering smoke sensors with different wavelengths (infrared and blue LED) FAP-OT 420 Optical, Thermal Combination of light scattering principle, rate of rise and fixed temperature measurement FAP-DOT 420 Dual-Optical, Thermal Dual Ray technology (see FAP-DO 420) in combination with rate of rise and fixed temperature measurement FAP-OTC 420 Optical, Thermal, Chemical Combination of light scattering principle, rate of rise and fixed temperature measurement as well as combustion gas FAP-DOTC 420 Dual-Optical, Thermal, Chemical Dual Ray technology (see FAP-DO 420) in combination with rate of rise and fixed temperature measurement as well as combustion gas Used where an open, fast-developing fire might occur Used where a smoldering fire might occur Used where equal response to different types of fire is essential Used where open, fastdeveloping fires, as well as smoldering fires, might occur Used in environments with varying conditions Used where CO gas might harm people Used in environments with special conditions to maintain, and where CO gas might harm people

3 FAP-OC 520 FAP-OC 520-P FAP-O 520 FAP-O 520-P FAD-O 420 and FAD-HS 420 EN Duct Detector White housing Multi-sensor in a combination of combustion gas and scattered-light sensor from any Multi-sensor de tection in a combination of combustion gas and scattered-light sensor Color rings can be fitted into the detector to adapt to the ceiling from any White housing from any Color rings can be fitted into the detector to adapt to the ceiling from any Use in ventilation systems with air velocities from 1 m/s to 20 m/s For the activation of fans, door controls or external display devices an optional relay board can be installed A clear section on the frosted cover allows to view alarm LED of integrated FAD-O 420 detector Tamper control High stability against disturbance values High stability against disturbance values Easy installation in air ducts Allows smoke in demanding environments

4 FAS-420-TM Aspirating Display sensitivity can be set to 0.05 %/m light oscuration RoomIdent fire localization 10 level smoke density display Innovative air flow sensor technology High Power Light Source Max. 8 aspiration openings and 40 m or 2x25 m pipe lenth FAS-420-TP Aspirating Display sensitivity can be set to %/m light oscuration 2 detector modules possible Innovative air flow sensor technology High Power Light Source Max. 48 aspiration openings and TP1: 300m; TP2:560m (2x280m) pipe lenth FAS-420-TT Aspirating Display sensitivity can be set to %/m light oscuration 2 detector modules possible Innovative air flow sensor technology High Power Light Source Max. 48 aspiration openings and TT1: 300m; TT2: 560m (2x280m) pipe lenth FMC-210 DM/SM Manual Call Point Different colors Single and double action Indoor and outdoor s FMC-420RW Manual Call Point Different colors Resettable or with glass pane Single-action call point Indoor and outdoor (IP67) s FMC-420RW Manual Call Point Outdoor Red color only Resettable or with glass pane Single-action EN54-11 and EN54-17 compliant Very early smoke even under challanging environmental conditions Minimalization of false due to intelligent signal processing Easy maintenance and service - no interruption of regular operations Up to 5 rooms can be individually monitored Very early smoke even under challanging environmental conditions Minimalization of false due to intelligent signal processing Easy maintenance and service - no interruption of regular operations 2-detector-dependency Very early smoke even under challanging environmental conditions Minimalization of false due to intelligent signal processing Easy maintenance and service - no interruption of regular operations 2-detector-dependency High flexibility Can be used for fire and other types of manual High flexibility Can be used for fire and other types of manual High flexibility Protection category according to EN 60529: IP67

5 FNM-420-A-BS-WH / FNM-420-A-BS-RD Base Sounder 2 types: red and white 90 db with current < 5 ma Constant sound pressure level in case of voltage drop Immediate and permanent synchronization of different sounder groups within one loop 32 tones Different sound pressure levels Combination with detector/beacon FNM-420-A- WH / FNM-420-A-RD Stand-alone Sounder Indoor 2 types: red and white 100 db with current < 5 ma Constant sound pressure level in case of voltage drop Immediate and permanent synchronization of different sounder groups within one loop 32 tones Different sound pressure levels Double entry back box for simplified installation FNM-420-B-RD Stand-alone Sounder Outdoor Red colour only Outdoor type with IP db with current < 5mA Constant sound pressure level in case of voltage drop Immediate and permanent synchronization of different sounder groups within one loop 32 tones Different sound pressure levels Double entry back box for simplified installation FNS-420-R Strobe Addressable strobe Freely configurable Combination with detector base or with LSN base sounder Low current consumption of 6 ma FLM-420-I2 Input Interface Module 2 monitored inputs Available as in-built, wall-mount and DIN-rail Contact or voltage monitoring Line monitoring with use of EOL resistor FLM-420-O2 Output Interface Module 2 open collector outputs Available as in-built, wall-mount and DIN-rail Max. switchable current per output 700 ma Max. switchable voltage per output 30 V DC Outputs are electrically isolated from LSN-loop and short-circuit proof FLM-420/4-CON Conventional Interface Module 2 fire zones class B or 1 fire zone class A Available as wall-mount and DIN-rail 200 ma max. supply current per Aux-output switchable Aux for resetting 4-wire detectors > 50 sounders per loop European tones covered Easy installation (sounder snaps into pre-installed mounting plate) Special mounting plate for surface mounted cabling Installation costs reduced by mounting detectors or beacons into the base sounder > 50 sounders per loop Very high, consistent sound pressure level at low power European tones covered Easy installation (comfortable back box with knock-outs and space for cabling) Very robust design > 50 sounders per loop Very high, consistent sound pressure level at low power European tones covered Easy installation (comfortable back box with knock-outs and space for cabling) Very robust weather-proof design Maximum light at 1 Hz frequency for high level of visibility Low current consumption allows connection of a large number of peripheral elements Allows integration with technical (e.g. freezer, air condition) The various monitoring types ensure customized applications Flexible control of external devices One class A or two class B zone Provides integration of conventional fire alarm periphery into LSN systems Compatible with 2- and 4-wire detectors Can be used with a wide range of conventional detectors

6 FLM-420-RLV1 Relay Interface Module Low Voltage FLM-420-RHV Relay Interface Module High Voltage FLM-420-NAC Signaling Device Interface Module FLM-I 420 Short Circuit Isolator FLM-420-RLV8-S Octo-relay Interface Module Low Voltage FLM-420-O8I2-S Octo-Output Interface Module with 2 Inputs FLM-420-I8R1-S Octo-Input Interface Module with Relay 1 low voltage relay 30 V/1 A LSN improved Available as in-built, wall-mount and DIN-rail 2 high voltage relays (240 V/10 A) 2 supervised feedback lines Available as surface mount and DIN-rail 1 supervised output line reversed polarity with up to 3 A Available as surface mount and DIN-rail Isolation of short circuits on LSN-Line Eight change-over contact relays provide potentialfree contact outputs Maximum switching capacity of the relays 2 A / 30 V DC Eight individually switchable open collector outputs Max. switchable current per output 700 ma Outputs electrically isolated from LSN loop and short circuit proof Individually selectable monitoring functions (EOL or contact) for the two inputs each Individually selectable monitoring functions (EOL or contact) for each of the 8 inputs Maximum switching capacity 2 A / 30 V DC Control of external applications Supervision and control of external applications e.g. extinguishing systems Supervised control of signaling devices Easy monitoring and activating of signaling devices Isolator for T-tap-systems Functionality of the remaining network is preserved Easy wiring thanks to pluggable terminal block Control of external applications Easy wiring thanks to pluggable terminal block Control of technical LED-tableaus Easy wiring thanks to pluggable terminal blocks Integration of technical

7 FLM-420-RLE-S Interface Module 1 low voltage relay (30 V, 1 A) 2 supervised input lines 1 input line programmable as relay feedback DIN-rail mountable Delivered with housing for surface mounting FLM-420-O1I1 Output-Input Interface Modules Open collector output electrically isolated from LSN loop and short-circuit proof Max. switchable current per output 700 ma Individually selectable input monitoring functions (EOL, contact or voltage) FK 100 LSN RF Interface Module Connection of up to 30 wireless detectors Bi-al data transfer MHz short range device Transmission path monitoring LSN classic DOW 1171 Radio Deception-proof operating behaviour High resistance to elec tromagnetic interference, temperature changes, humidity, corrosion and contamination Smoke detector with outstanding interference immunity Conntectable to FK-100-LSN MPA Detector Remote Indicator DIN 14623, ATEX PTB01, ATEX 2163X Good visibility Elegant, robust and efficient design Easy localization of detectors Compatible to LSN-classic and LSN improved FAA-RI 420 Remote Indicator Good visibility Elegant, robust and efficient design Easy localization of detectors Compatible to LSN-classic and LSN improved Supervision and control of external applications, e.g. extinguishing systems Conformity to VdS 2496: 2005 Low supply current Available as in-built and DIN-rail Control of external devices Easy expansion of existing fire alarm systems High transmission and functional security Outstanding interference immunity Easy extension of existing fire alarm systems without additional wiring VdS approved Parallel indication for detectors in false ceilings Mounting in corridors or access pathways Parallel indication for detectors in false ceilings Mounting in corridors or access pathways Cost-efficient solution

Interface and EOL Modules 8

Interface and EOL Modules 8 Interface and EOL Modules Interface Modules Series 420 25 Interface Modules Series 100 291 EOL Modules 293 254 Interface and EOL Modules Interface Modules Series 420 Interface Modules Serie 420 Interface

More information

Conventional Fire Panel 500 Series

Conventional Fire Panel 500 Series Quick Panel Guide FPC-500-2 FPC-500-4 FPC-500-8 fzones 2 4 8 Programmable inputs 1 1 2 AUX output 1 1 1 Outputs sounder/strobe 2 2 2 Relays 2 2 2 Alarm counter 999 alarms 999 alarms 999 alarms Event history

More information

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version Fire Alarm Systems FAP-420/FAH-420 Automatic Fire Detectors LSN improved version FAP-420/FAH-420 Automatic Fire Detectors LSN improved version ombination of optical, thermal and chemical sensors with intelligent

More information

Automatic Fire Detectors LSN improved

Automatic Fire Detectors LSN improved Automatic Fire Detectors LSN FAP-DO420/FAP-420/FAH-420 en Operation Guide Automatic Fire Detectors LSN Table of Contents en 3 Table of contents 1 Product Description 5 2 System Overview 6 2.1 Detector

More information

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V. Signaling Devices Acoustic Signaling Devices 28 Optical Signaling Devices 30 26 Signaling Devices Acoustic Signaling Devices Acoustic Signaling Devices MSS300-SA SG 200 DS 10 LSN/GLT GLT GLT GLT Operating

More information

AVENAR detector 4000 FAP-425 / FAH-425. en Operation Guide

AVENAR detector 4000 FAP-425 / FAH-425. en Operation Guide AVENAR detector 4000 FAP-425 / FAH-425 en Operation Guide AVENAR detector 4000 Table of Contents en 3 Table of contents 1 Product Description 4 2 System Overview 5 2.1 Functional Description of the Sensor

More information

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features. Wireless Overview www.incitefire.com.au Overview Fundamentals FIREwave is a wireless based family of products which is fully integrated into Hochiki s renowned ESP intelligent hardwired system. This seamless

More information

Consultant Specification AGILE Wireless Fire Detection System

Consultant Specification AGILE Wireless Fire Detection System Contents Scope of Work... 2 The EN54 Part 2 & 4 Fire System... 2 Standards... 2 Wireless Intelligent Photoelectric Smoke Detector Specification... 4 Wireless Intelligent Thermal Heat Detector Specification...

More information

Quick Selection Guide Analog Addressable Fire Systems

Quick Selection Guide Analog Addressable Fire Systems Quick Selection Guide Analog Addressable Fire Systems www.boschsecurity.com February 2018 A focused direction in fire protection With features that enable easier programming, installation and system management,

More information

Automatic Fire Detectors

Automatic Fire Detectors Automatic Fire Detectors LSN Detectors 122 Accessories - Series 500 LSN and 520 LSN 133 Accessories - Series 420 LSN improved version 140 LSN RF Fire Detection Systems 152 Accessories - LSN RF Fire Detection

More information

Solution F2. Fire Alarm Control Panels one step ahead.

Solution F2. Fire Alarm Control Panels one step ahead. Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution

More information

OOH740, OOHC740 Automatic fire detectors

OOH740, OOHC740 Automatic fire detectors OOH740, OOHC740 Automatic fire detectors ASAtechnology TM For the automatic addressable detector bus C-NET Collective / Conventional (OOH740 only) Cerberus PRO Signal processing with ASAtechnology TM Event-controlled

More information

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

ZIOU/230 - MAINS IO INSTRUCTION MANUAL Description ZIOU/230 - MAINS IO INSTRUCTION MANUAL The Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third party equipment with the Fire Alarm Control panel

More information

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version. Product Information

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version. Product Information FAP-420/FAH-420 Automatic Fire Detectors LSN improved version en Product Information FAP-420/FAH-420 Table of Contents en 3 Table of Contents 1 Product Description 5 2 System Overview 6 2.1 Configuration

More information

Modular Fire Panel 5000 Series Just as flexible as your plans

Modular Fire Panel 5000 Series Just as flexible as your plans Modular Fire Panel 5000 Series Just as flexible as your plans 2 One modular system does it all Unbeatable flexibility With the Modular Fire Panel 5000 Series, Bosch is again redefining the market: With

More information

FCS-320-TM Series Conventional Aspirating Smoke Detectors

FCS-320-TM Series Conventional Aspirating Smoke Detectors Fire Alarm Systems FCS-320-TM Series Conventional Aspirating Smoke Detectors FCS-320-TM Series Conventional Aspirating Smoke Detectors For connecting to conventional fire panels High deceptive alarm immunity

More information

OH110, OP110, HI110 Automatic fire detectors

OH110, OP110, HI110 Automatic fire detectors OH110, OP110, HI110 Automatic fire detectors For collective and conventional detector lines Signal processing with detector algorithms Selectable parameter sets 3 color LED indication Drift compensation

More information

Fireray 2000 Linear Smoke Detector

Fireray 2000 Linear Smoke Detector Fire Alarm Systems Fireray 2000 Linear Smoke Detector Fireray 2000 Linear Smoke Detector Extended monitoring area Increased security against false alarms with gain control Potential-free, self-holding

More information

INPUT / OUTPUT MINI MODULES

INPUT / OUTPUT MINI MODULES INPUT / OUTPUT MINI MODULES APPLICATION The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors

More information

Instructions for the Fire System Designer (FSD) Rel. 2.1

Instructions for the Fire System Designer (FSD) Rel. 2.1 Instructions for the Fire System Designer Rel. 2.1 1/6 Instructions for the Fire System Designer (FSD) Rel. 2.1 Instructions for the Fire System Designer Rel. 2.1 2/6 Table of Contents 1 Introduction...3

More information

Conventional Automatic Detectors FCP-320 FCH-320

Conventional Automatic Detectors FCP-320 FCH-320 Conventional Automatic Detectors FCP-320 FCH-320 en Operation Guide Conventional Automatic Detectors Table of contents en 3 Table of contents 1 Product Description 5 2 System Overview 6 2.1 Configuration

More information

FCP 320/FCH 320 Conventional Automatic Fire Detectors

FCP 320/FCH 320 Conventional Automatic Fire Detectors Fire Alarm Systems FCP 320/FCH 320 Conventional Automatic Fire Detectors FCP 320/FCH 320 Conventional Automatic Fire Detectors High reliability of detection thanks to evaluation electronics Active adjustment

More information

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.

More information

Analogue addressable devices

Analogue addressable devices Apollo XP95 Analogue addressable devices from Channel Safety Systems Apollo XP95 Analogue addressable devices The XP95 range of analogue addressable fire detectors is advanced in design, improved in performance

More information

Fire control panel detect 3004 plus and accessories

Fire control panel detect 3004 plus and accessories Fire control panel detect 3004 and accessories The modular fire alarm panel detect 3004 is the basic version of a broad product portfolio of the system detect 3000. Up to 20 fire control panels can be

More information

Cerberus FIT conventional system

Cerberus FIT conventional system Cerberus FIT conventional system Combining intelligent signal processing and easy installation for reliable fire detection and alarming www.siemens.com/cerberus-fit Reliable, intelligent and cost-efficient

More information

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved. TX7130 Conventional Reflective Beam Detector Installation and Operation Manual Technology Copyright 2015, All right reserved. Product Safety To prevent severe injury and loss of life or property, read

More information

Just as flexible as your plans The Bosch Modular Fire Panel 5000 Series

Just as flexible as your plans The Bosch Modular Fire Panel 5000 Series Just as flexible as your plans The Bosch Modular Fire Panel 5000 Series 2 One modular system does it all Unbeatable flexibility With the Modular Fire Panel 5000 Series, Bosch is again redefining the market:

More information

Polycarbonate External Sounder & Strobe Unit

Polycarbonate External Sounder & Strobe Unit Polycarbonate External Sounder & Strobe Unit Designed for maximum reliability at the most cost-effective price, the Odyssey 1E brings high security sounder technology into the residential marketplace.

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops... GUIDE MANUAL INDEX 1- Introduction...5...5...6 4- The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops...7 4.2- The Control Panel 4 and 8 Loops...9 5- Installation Guide...10 5.1- Pre-Installation

More information

The new detector from Rafiki

The new detector from Rafiki The new detector from Rafiki Three smoke detectors Three heat detectors Combined smoke/heat detector Full alarm sounder Strobe End-of-line device/loop isolator Rafiki s Multipoint ASD detector range have

More information

FPA 5000 With Functional Modules

FPA 5000 With Functional Modules Fire Alarm Systems FPA 5000 With Functional Modules FPA 5000 With Functional Modules Modular configuration allowing for easy extension Easy adaptation to country-specific regulations and conditions Complete

More information

FPA 5000 With Functional Modules

FPA 5000 With Functional Modules Fire Alarm Systems FPA 5000 With Functional s FPA 5000 With Functional s Modular configuration allowing for easy extension Easy adaptation to country-specific regulations and conditions Complete set-up

More information

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE Cerberus PRO Marine Fire and Detection Equipment s FH-2071-UM, BP-62 and USCG-HPLATE Cerberus PRO Fire Safety Products ARCHITECT AND ENGINEER SPECIFICATIONS Marine equipment is used with Cerberus PRO 252-point

More information

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel Synova TM Commissioning in no time thanks to automatic address allocation Auto-addressing makes setting dip switches unnecessary Automatic

More information

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors Cerberus PRO OOH740, OOHC740 Automatic fire detectors ASAtechnology For the automatically addressable detector bus C-NET collective / conventional (OOH740 only) Signal processing with ASAtechnology Event-controlled

More information

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION FIRE DETECTION >FIRE DETECTION CONVENTIONAL C400 SYSTEM FIRE DETECTION EFFICIENT AND MODULAR Elkron fire detection systems protect your business and grow with it Elkron's conventional fire detection range

More information

>WIRELESS> ALARM SYSTEM CR200

>WIRELESS> ALARM SYSTEM CR200 intrusion >WIRELESS> ALARM SYSTEM CR200 INTRUSION HOME SECURITY CR200 is a Modern, Effective and Versatile 20-zone Household Security System. It is packed with simple Plug & Play functionality, designed

More information

Fire Detection Systems Intelligent detection. Superior protection.

Fire Detection Systems Intelligent detection. Superior protection. A Tradition of Quality and Innovation For over 125 years, the Bosch name has stood for quality and reliability. Bosch is the global supplier of choice for innovative technology, backed by the highest standards

More information

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ELECTRONIC SOUNDER STROBE Model : AVD-C407 ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an

More information

IQ8Control C Fire Alarm Panel

IQ8Control C Fire Alarm Panel IQ8Control C Fire Alarm Panel State-of-the-art processor technology Maximum cable length for esserbus: 3,500 m Graphics supported, high performance programming tool Innovative alarm signalling by means

More information

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER Application The unit is primarily intended for use where there is a requirement to integrate a limited fire protection function into a larger control equipment scheme, or in specialist applications where

More information

intelligent solutions

intelligent solutions Alco is one of the leading intelligent solution providers of Fire Detection System. Security System and Public Addressing System in the United States of America. Based in California since 1992, we have

More information

Evolution Analogue Addressable Fire System

Evolution Analogue Addressable Fire System Addressable Fire System optimum fire safety systems solutions High speed FSK protocol, uniquely resistant to noise Up to 254 addresses per loop for flexible system design Built to exceptional marine standards

More information

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector ISC-PDL1-W18G-H EN Installation Instructions Professional Series Dual Detector 1.0 General Information 1.1 Unlock and remove the cover The ISC-PDL1-W18x Professional Series TriTech Detectors are exceptionally

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

designed for rail 5000 Series

designed for rail 5000 Series designed for rail 5000 Series 5000 Series The only complete SIL system 20 years of experience in the field. More than 15.000 systems supplied worldwide. A team devoted to rolling stock projects with specialized

More information

VdS SCHADENVERHÜTUNG. VdS-Rules for Intruder Alarm Systems

VdS SCHADENVERHÜTUNG. VdS-Rules for Intruder Alarm Systems VdS SCHADENVERHÜTUNG VdS Publisher: Gesamtverband der Deutschen Versicherungswirtschaft e.v. (GDV) Büro Schadenverhütung Publishing house: VdS Schadenverhütung. All rights reserved. VdS-Rules for Intruder

More information

Sita200plus. 200detectors. Single loop analogue addressable System

Sita200plus. 200detectors. Single loop analogue addressable System Single loop analogue addressable System Fast short circuit isolator in every device 15 combinations of smoke & heat detection modes Loop length up to 2km long with spurs INTELLIGENT FIRE TECHNOLOGY A D

More information

FC724 Fire control panel

FC724 Fire control panel FC724 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as

More information

DICTATOR Hold-Open Systems for Hazardous Areas

DICTATOR Hold-Open Systems for Hazardous Areas DICTATOR for Hazardous Areas Products to be used in hazardous areas obviously have to meet special demands. The European ATEX directives (first the EN 94/9/EG and then the directive 2014/34/ EU) brought

More information

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices. FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001

More information

FC722 Fire control panel

FC722 Fire control panel FC722 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as

More information

IFD-E Flame Detector User Manual

IFD-E Flame Detector User Manual IFD-E Flame Detector User Manual 2 Hochiki Europe (UK) Ltd General Description The flame detector is designed for use where open flaming fires may be expected. It responds to the light emitted from flames

More information

COMPACT FLAME CONTROLLER CFC 2000

COMPACT FLAME CONTROLLER CFC 2000 COMPACT FLAME CONTROLLER CFC 2000 TECHNICAL DESCRIPTION EDITION: TB_CFC2000_EN_REV09_20150408 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring

More information

Vista-50P/-50PUL System Design Sheet

Vista-50P/-50PUL System Design Sheet Vista-50P/-50PUL System Design Sheet INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO ACCESS CONTROL SECTION 1: Basic Vista-50P (Nine Hardwired Zones, One Addressable Loop, Wireless)

More information

Rules for Intruder Alarm Systems

Rules for Intruder Alarm Systems Rules for Intruder Alarm Systems Opening detectors (Magnetic contacts) Part 1: Requirements VdS 2120en 03/96 (03) Subject 44 1 General; 2 Terms and definitions; 3 Classification 1 General 1.1 Scope These

More information

FC724 Fire control panel

FC724 Fire control panel FC724 Fire control panel Series FS720 (IP5) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as

More information

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules Application The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors and manual call points,

More information

Fire Product Catalog

Fire Product Catalog Additional Expansion Modules Fire Product Catalog CLEVER FIRE SOLUTIONS MA 1000 / Analog Addressable Fire Alarm Panel 1 Military Industry Public Buildings Industrial & Commercial Company Profile We are

More information

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi (P/N 10-068) is a state-of-the-art true intelligent digital peer-topeer modular suppression control system. It is ideal for

More information

Fire & Security Products. Siemens Building Technologies Group

Fire & Security Products. Siemens Building Technologies Group Fire & Security Products Siemens Building Technologies Group . 1 Brief overview.................................................... 1 1.1 Characteristics....................................................

More information

Cerberus PRO enjoy protecting A comprehensive fire protection system

Cerberus PRO enjoy protecting A comprehensive fire protection system Cerberus PRO enjoy protecting A comprehensive fire protection system CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800) 444-8719 Cerberus PRO enjoy protecting Protecting people

More information

Description. Optex Incorporated

Description. Optex Incorporated Optex Incorporated Description 1845 W. 205 th St. Torrance, CA 90501-1510 USA TEL (310) 533-1500 and (800) 966-7839 FAX (310) 533-5910 Doc: Model: Desc: Architect/ Engineer Specifications CX-502 PIR Intrusion

More information

Addressable Fire Alarm Control Panel

Addressable Fire Alarm Control Panel PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT

More information

Basic Fire Alarm SystemTraining. Arman Alnasar

Basic Fire Alarm SystemTraining. Arman Alnasar Basic Fire Alarm SystemTraining Arman Alnasar Agenda Introduction to Esser 10 min Product Overview 5 min Control Panels 30 min Detectors 20 min Field Devices Alarm Devices 20min 10 min Management & Interface

More information

MINERVA MZX125 Digital Addressable Fire Detection System

MINERVA MZX125 Digital Addressable Fire Detection System DATASHEET MINERVA MZX125 Digital Addressable Fire Detection System The Minerva MZX125 is a highly featured digital addressable panel with a comprehensive but easy to operate user interface. The system

More information

COMPACT FLAME CONTROLLER CFC 1000

COMPACT FLAME CONTROLLER CFC 1000 COMPACT FLAME CONTROLLER CFC 1000 TECHNICAL DESCRIPTION EDITION: TB CFC1000- REV.6 2012-03-07 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring

More information

New generation FPA-5000/1200. Kristof Vandenberghe

New generation FPA-5000/1200. Kristof Vandenberghe New generation FPA-5000/1200 Kristof Vandenberghe 1 Table of content New panel controller Modifications FSP-5000-RPS Uninterruptible acoustic notification 2 New panel controller General information: New

More information

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel Synova Commissioning in no time thanks to automatic address allocation Auto-addressing makes setting dip switches, punch cards, etc. unnecessary

More information

IFD-E Flame Detector User Manual

IFD-E Flame Detector User Manual IFD-E Flame Detector User Manual 2 Hochiki Europe (UK) Ltd General Description The flame detector is designed for use where open flaming fires may be expected. It responds to the light emitted from flames

More information

OH110, OP110, HI110. Automatic Fire Detectors. Automatic Fire Detector For collective and conventional detector lines

OH110, OP110, HI110. Automatic Fire Detectors. Automatic Fire Detector For collective and conventional detector lines Automatic Fire Detector For collective and conventional detector lines Signal processing with detector algorithms Selectable parameter sets 3 colour LED indication Drift compensation Internal fault monitoring

More information

ACP10 & ACP50 Security Systems

ACP10 & ACP50 Security Systems ACP10 & ACP50 Security Systems System Configuration LCD Keypad LCD Keypad LED Keypad LED Keypad 4-wire Bus ACP10 & ACP50 AEX10* AEX10* AEX10* AEX10* * ACP50 Only Control Panels The ACP10 control panel

More information

MINERVA MX. 800 Series Ancillary Equipment

MINERVA MX. 800 Series Ancillary Equipment An extensive range of ancillary modules has been specifically designed for use with the MX range of Fire Controllers. The 800 range of ancillary modules provide the MX Fire Controller with a wide degree

More information

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers Intrusion Systems UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers Up to 6 UEZ LSNs can be networked with system loop technology (SRT) Fire

More information

Operating Manual MS220KA and MSR220KA

Operating Manual MS220KA and MSR220KA Temperature Relays and MINIKA, Mains Monitoring, Digital Panel meters MINIPAN, Switching Relays and Controls Operating Manual MS220KA and MSR220KA ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße

More information

D7024 Fire Alarm Control Panel

D7024 Fire Alarm Control Panel D7024 Fire Alarm Control Panel The D7024 offers accurate, consistent performance with a feature set that elevates this panel to the top of its class. Fire systems you can rely on. D7024 24V Addressable

More information

Product Documentation

Product Documentation Product Documentation LSN radio fire detection system LSN Local SecurityNetwork This documentation details planning, installation and initial set-up and is only intended for users of our systems. This

More information

FC723 Fire control panel

FC723 Fire control panel FC723 Fire control panel FS720 series (IP5) Cerberus PRO Modular, prefabricated, microprocessor-controlled fire control panel with integrated user-friendly operating unit for up to max. 756 addresses Processes

More information

Addressable Loop Powered Visual Alarm Devices

Addressable Loop Powered Visual Alarm Devices Addressable Loop Powered Visual Alarm Devices About Who is? has a long and proud tradition in fire detection. Founded in Munich in 1877 as Elektrotechnische Fabrik Alois it quickly became a recognized

More information

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version Fire Alarm Systems FAP-420/FAH-420 Atomatic Fire Detectors LSN improved version FAP-420/FAH-420 Atomatic Fire Detectors LSN improved version www.boschsecrity.com Combination of optical, thermal and chemical

More information

EnvironmentalMonitoring

EnvironmentalMonitoring Datasheet Numerous sensors, detectors and expansion modules are available for the requirements in ambient and device monitoring. All units are self-developed by Neol so the highest technical requirements

More information

Installation and Operation Manual

Installation and Operation Manual [Please read this installation & operation manual before install and use this Installation and Operation Manual Address: 8-701,Dongfangming Industry Zone, Dabao Road., Baoan, Shenzhen, China-518101 Page

More information

Operating Manual MS220DA

Operating Manual MS220DA ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße 13, D 74523 Schwäbisch Hall + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panel Meters MINIPAN

More information

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon alarm devices For fire detector and extinguishing systems Loud alarm signal clearly recognizable as a danger signal even in noisy environments

More information

Integrated Security Solutions

Integrated Security Solutions Integrated Security Solutions Table of Contents Control Panels 4 Keypads 8 Communication Modules 16 I/O Expanders 20 Door Control 24 Home Automation 25 RF Receivers 26 3 Our integrated security solutions

More information

Addressable Detectors & Bases

Addressable Detectors & Bases Edwards Signaling Catalog u Intelligent Initiating Addressable Detectors & Bases Detectors: E-PD, E-PHD, E-HD Bases: B4U, RB4U, IB4U, SB4U Overview Edwards intelligent addressable detectors are meticulously

More information

OH720, OP720, HI720, HI722

OH720, OP720, HI720, HI722 Cerberus PRO OH720, OP720, HI720, HI722 Automatic fire detectors For the automatically addressable detector bus C-NET The ideal fire detector for every application Signal processing with detection algorithms

More information

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10 PRODUCT INFORMATION PI 38.43 Sounder SG 200 Page 1 of 10 Table of Contents 1. Product Description............................... 3 2. Features......................................... 3 3. Functional Description............................

More information

Control Panels and Fire Detection Equipment

Control Panels and Fire Detection Equipment Control Panels and Fire Detection Equipment Quaestor-SZU... Page 03 Quaestor-SZU Ancillary Board.... Page 04 Quaestor-MZE BS... Page 05 Quaestor-SZE BS... Page 06 Quaestor-SZE Ancillary Board... Page 07

More information

FC700A Fire detection control unit

FC700A Fire detection control unit FC700A Fire detection control unit Synova 4-16 Loop analogue addressable control panel 128 devices per loop (SynoLOOP) and up to 1000 devices per panel Up to 24 collective lines for Synova TM 600 serie

More information

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum

More information

Remote NAC Power Supply D7038

Remote NAC Power Supply D7038 Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus

More information

Conventional Fire Detection

Conventional Fire Detection SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct

More information

GSME. Industrial-suited fire gas detectors with multiple semiconductor gas-sensors, integrated signal evaluation and M-Bus interface

GSME.  Industrial-suited fire gas detectors with multiple semiconductor gas-sensors, integrated signal evaluation and M-Bus interface GSME 408-2001-x GSME Industrial-suited fire gas detectors with multiple semiconductor gas-sensors, integrated signal evaluation and M-Bus interface Characteristics Sturdy design with aluminium diecast

More information

System 800 Addressable Fire Detection & Alarm System

System 800 Addressable Fire Detection & Alarm System SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools

More information

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing Control Panels Control Panels for Commercial Applications Control panels provide the central processing and logic for an integrated system. In a typical system, there are four major functions: inputs,

More information

For Complete Fire and Gas Solutions

For Complete Fire and Gas Solutions Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable

More information

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation Sinteso Cerberus PRO FDA241, FDA221 ASD Aspirating smoke detector Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation Patented technology Early

More information