Series 9000 Total Hydrocarbon Analyzer

Size: px
Start display at page:

Download "Series 9000 Total Hydrocarbon Analyzer"

Transcription

1 Series 9000 Total Hydrocarbon Analyzer Analyzer The Baseline Series 9000 is the candidate of choice whenever accurate, reliable total hydrocarbon analysis is required. The Series 9000 analyzer provides unparalleled flexibility and offers continuous, fully automated gas analysis over a broad range of concentrations. The 9000 has a dynamic range from less than 10 ppb on the low range version and up to 100% as methane on the high range version. The analyzer has a generous complement of analog, digital and logic output capabilities. The analyzer is based on a flame ionization detector (FID) with FlowGuard electronic control that delivers a small portion of the sample gas to the detector flame. During the combustion process, organic or hydrocarbon-based gases in the sample are ionized then they are detected by the instrument and reported as a concentration. The Series 9000 can be configured with internal components for single or multipoint analysis of non-condensing gas samples. The automatic calibration feature enhances the long-term analytical stability of the instrument. These features place the instrument well ahead of the competition in performance, automation, and configurability. Applications The Series 9000 is designed to continuously monitor the total hydrocarbon content of non-condensing gases in a variety of applications, such as: Beverage grade CO analysis 2 Scrubber & oxidizer efficiency Carbon bed breakthrough detection Contaminant analysis in pure/ultrapure inert gases Well logging Industrial hygiene & safety monitoring Fenceline (perimeter) monitoring around industrial sites LEL monitoring Features Flame ionization detector. 3U case, 19 (48.3cm) rack mountable. Automatic calibration at user-defined intervals. Internal, multipoint sampling option. FlowGuard electronic control of fuel, air and sample. Electronic back-pressure regulator with sample bypass system ensures fast response. Discrete, multilevel concentration & fault alarms. Analog output ranges programmable from 1ppm 100% full scale. Programmable relays for concentration alarms, events and diagnostics. Automatic FID ignition, with automatic shut-off of sample, fuel and combustion air. Remote operation via RS-232 and Ethernet. Graphical display and easy to use menu system. Optional 9000 Keeper software to monitor and control the instrument remotely.

2 Series 9000 Total Hydrocarbon Analyzer Analytical Detector: Flame ionization detector (FID). Ranges: User definable based upon calibration within: MDQ 0.01ppm, Full-scale 1-200ppm (Methane) MDQ 0.1ppm, Full-scale 1-2,000ppm (Methane) MDQ 0.3ppm, Full-scale 1-20,000ppm (Methane) MDQ 0.003%, Full-scale % (Methane) Repeatability: +/- 1% Full-scale response. Drift: +/- 1% of full-scale over 24 hours. Response Time: < 5 seconds to 90% of final reading. Alarms: Multilevel concentration and fault alarms that result in audible and visual alarms. Alarms may also be mapped to relays to control external equipment. Sampling: Internal single or multipoint modules, for pre-filtered (<0.1 microns) non-condensing samples, with or without sample pump. Calibration: Programmable automatic or manual calibration. Support Gas: Hydrogen 35 cc/min, Air 175 cc/min (typical). Hydrocarbon content must be less than 1 ppm. Fuel blend options available, consult Baseline. Physical Dimensions: (48.3cm) W x (36.2cm) D x 5.25 (13.3cm) H. Weight: < 20 lb (9.07kg). Configuration: Bench-top or rack-mount 19 (48.3cm) panel. Connections: 1/4 (6.35mm) tube fitting connectors. Operating Temperature: F (0-40 C). Operating Humidity: 0 95% (non-condensing). Electrical Power: VAC, 50/60Hz, 3A. Display: 3.4 (8.6cm) x 4.5 (11.4cm) graphical display. Relay Outputs: 5 programmable form A relays rated to 230V AC (optional additional 9 relay output Analog Outputs: 1 programmable 0-20mA or 4-20mA isolated output (optional additional 3 analog output Digital Outputs: RS-232, Ethernet. P.O. Box 649, Highway 36 Lyons, CO P: F: E: Sales@BaselineIndustries.com D011.4

3 Series 9000 NMHC NonMethane Hydrocarbon Analyzer Analyzer The Baseline Series 9000 NMHC is a specialized member of the extraordinary Series 9000 family of gas analyzers. The Series 9000 is the candidate of choice whenever accurate, reliable total, Methane, and NonMethane analysis is required. The Series 9000 analyzer provides unparalleled flexibility and offers continuous, fully automated gas analysis over a broad range of concentrations. The Series 9000 NMHC is designed to measure the total, methane, and non-methane hydrocarbon content of gas samples. The analyzer has a generous complement of analog, digital and logic output capabilities. The analyzer is based on a flame ionization detector (FID) and an oxidation catalyst that is switched in and out of a portion of the sample stream. The catalyst oxidizes all hydrocarbons except methane, for a methane measurement. The methane value is then automatically subtracted from the total hydrocarbon concentration to determine the nonmethane hydrocarbon reading. The Series 9000 NMHC can be configured with internal components for single or multipoint analysis of noncondensing gas samples. The automatic calibration feature enhances the long-term analytical stability of the instrument. These features place the instrument well ahead of the competition in performance, automation, and configurability. Applications The Series 9000 NMHC is designed to continuously monitor the total hydrocarbon content of non-condensing gases in a variety of applications, such as: Ambient Air Monitoring Networks Clean Rooms Air & Oxygen Purity in Air Separation Plants Features Flame ionization detector. 3U case, 19 (48.3cm) rack mountable. Hydrocarbon detection from sub-ppm to 1000ppm (Methane). Automatic calibration at user-defined intervals. Internal, multipoint sampling option. FlowGuard electronic control of fuel, air and sample. Electronic back-pressure regulator with sample bypass system ensures fast response. Discrete, multilevel concentration & fault alarms. Programmable analog output ranges. Programmable relays for concentration alarms, events and diagnostics. Automatic FID ignition, with automatic shut-off of sample, fuel and combustion air. Remote operation via RS-232 and Ethernet. Graphical display and easy to use menu system. Optional 9000 Keeper software to monitor and control the instrument remotely.

4 Series 9000 NMHC NonMethane Hydrocarbon Analyzer Analytical Detector: Flame ionization detector (FID). Oxidizer: Oxidizes NonMethane gases. Range: User definable based upon calibration within: MDQ 0.06ppm, Full-scale 1-200ppm (Air Balance) MDQ 0.1ppm, Full-scale ppm (Air Balance) MDQ 0.03ppm, Full-scale 1-200ppm (O 2 Balance) Repeatability: +/- 1% Full-scale response. Drift: +/- 1% of Full-Scale over 24 hours. Response Time: T90 < 30 sec. Alarms: Multilevel concentration and fault alarms that result in audible and visual alarms. Alarms may also be mapped to relays to control external equipment. Sampling: Internal single or multipoint modules for pre-filtered (<0.1 microns), non-condensing samples with or without sample pump. Calibration: Programmable automatic or manual calibration. Support Gas: Hydrogen 35 cc/min (H 2 He Blend 100cc/ min), Air 175 cc/min (typical). Hydrocarbon content must be less than 1 ppm. Fuel blend options available, consult Baseline. Physical Dimensions: (48.3cm) W x (36.2cm) D x 5.25 (13.3cm) H. Weight: < 20 lb (9.07kg). Configuration: Bench-top or rack-mount 19 (48.3cm) panel. Connections: 1/4 (6.35mm) tube fitting connectors. Operating Temperature: F (0-40 C). Operating Humidity: 0 95% (non-condensing). Electrical Power: VAC, 50/60Hz, 3A. Display: 3.4 (8.6cm) x 4.5 (11.4cm) graphical display. Relay Outputs: 5 programmable form A relays rated to 230V AC (optional additional 9 relay output Analog Outputs: 1 programmable 0-20mA or 4-20mA isolated output (optional additional 3 analog output Digital Outputs: RS-232, Ethernet. P.O. Box 649, Highway 36 Lyons, CO P: F: E: Sales@BaselineIndustries.com D018.5

5 Series 9000 TCA Total Carbon Analyzer Analyzer The Baseline Series 9000 TCA is a specialized member of the extraordinary Series 9000 family of gas analyzers. The Series 9000 is the candidate of choice whenever accurate, reliable total hydrocarbon and total carbon analysis is required. The Series 9000 analyzer provides unparalleled flexibility and offers continuous, fully automated gas analysis over a broad range of concentrations. The Series 9000 TCA has a dynamic range from less than 0.1 ppm to 100 ppm, it s designed to measure total hydrocarbon content and provide a combined carbon monoxide (CO) and carbon dioxide (CO 2 ) reading. The analyzer has a generous complement of analog, digital and logic output capabilities. The analyzer is based on a flame ionization detector (FID) and a reduction catalyst that is switched in and out of a portion of the sample stream. Total hydrocarbons are measured first, and then the catalyst switches in. The catalyst converts the CO & CO 2 to methane and leaves the hydrocarbons unchanged for a total carbon measurement. The total hydrocarbon value is then automatically subtracted from the total carbon concentration to determine the combined CO/CO 2 reading The Series 9000 TCA can be configured with internal components for single or multipoint analysis of noncondensing gas samples. The automatic calibration feature enhances the long-term analytical stability of the instrument. Applications The Series 9000 TCA is designed to continuously monitor total hydrocarbons and trace levels of CO/CO 2 in order to provide a total carbon reading. This specialized analyzer is configured for the detection of hydrocarbon and CO/CO 2 impurities in pure and ultrapure inert gases such as argon, helium, hydrogen, and nitrogen. Samples must be free of oxygen. Features Flame ionization detector. 3U case, 19 (48.3cm) rack mountable. Hydrocarbon detection from sub-ppm to 100 ppm levels. Automatic calibration at user-defined intervals. Internal, multipoint sampling option. FlowGuard electronic control of fuel, air and sample. Electronic back-pressure regulator with sample bypass system ensures fast response. Discrete, multilevel concentration & fault alarms. Analog output ranges programmable from 1ppm 100% full scale. Programmable relays for concentration alarms, events and diagnostics. Automatic FID ignition, with automatic shut-off of sample, fuel and combustion air. Remote operation via RS-232 and Ethernet. Graphical display and easy to use menu system. Optional 9000 Keeper software to monitor and control the instrument remotely.

6 Series 9000 TCA Total Carbon Analyzer Analytical Detector: Flame ionization detector (FID). Methanizer: Converts low levels of CO and CO 2 to methane. Range: User definable based upon calibration within: ppm (Methane). MDQ: 0.1 ppm (100 ppb). Repeatability: +/- 1% Full-scale response. Drift: Zero: +/- 1% Full-scale over 24 hours Response Time: T90 < 30 sec. Alarms: Multilevel concentration and fault alarms that result in audible and visual alarms. Alarms may also be mapped to relays to control external equipment. Sampling: Internal single or multipoint modules for pre-filtered (<0.1 microns), non-condensing samples, with or without sample pump. Physical Dimensions: (48.3cm) W x (36.2cm) D x 5.25 (13.3cm) H. Weight: < 20 lb (9.07kg). Configuration: Bench-top or rack-mount 19 (48.3cm) panel. Connections: 1/4 (6.35mm) tube fitting connectors. Operating Temperature: F (0-40 C). Operating Humidity: 0 95% (non-condensing). Electrical Power: VAC, 50/60Hz, 3A. Display: 3.4 (8.6cm) x 4.5 (11.4cm) graphical display. Relay Outputs: 5 programmable form A relays rated to 230V AC (optional additional 9 relay output Calibration: Programmable automatic or manual calibration. Support Gas: Hydrogen 40 cc/min, Air 200 cc/min. (typical). Hydrocarbon content must be less than 1 ppm. Fuel blend options available, consult Baseline Analog Outputs: 1 programmable 0-20mA or 4-20mA isolated output (optional additional 3 analog output Digital Outputs: RS-232, Ethernet. P.O. Box 649, Highway 36 Lyons, CO P: F: E: Sales@BaselineIndustries.com D019.4

7 Series 9000 H Heated Hydrocarbon Analyzer Analyzer The Baseline Series 9000 H is a high-temperature member of the extraordinary Series 9000 family of gas analyzers. The Series 9000 is the candidate of choice whenever accurate, reliable hydrocarbon analysis is required. The Series 9000 H has a dynamic range from 0.1 ppm to 10% (Propane) or 0.3 ppm to 50% (Methane). The analyzer has a generous complement of analog, digital and logic output capabilities. These features place the instrument well ahead of the competition in performance, automation, and configurability. The analyzer is based on a flame ionization detector (FID) with FlowGuard electronic control that delivers a small portion of the sample gas to the detector flame. During the combustion process, organic or hydrocarbon-based gases in the sample are ionized then they can be detected by the instrument and reported as a concentration. The Series 9000 H is configured for single point analysis of samples heated up to 376 F (191 C). The automatic calibration feature enhances the long-term analytical stability of the instrument. Applications The Series 9000 H is designed to continuously monitor the total hydrocarbon content of gases and maintain the temperature of heated sample above their dew point. This extremely versitile instrument can be configured to support a variety of applications, such as: Compliance monitoring for EPA Methods 25A & 503 Continuous Emission Monitoring (CEM) of source hydrocarbons Scrubber & oxidizer efficiency Carbon bed breakthrough detection LEL monitoring Vehicle emissions Chemical process blending Features Flame ionization detector. 3U case, 19 (48.3cm) rack mountable. Hydrocarbon detection from sub-ppm to 50% levels (Methane). Automatic calibration at user-defined intervals. FlowGuard electronic control of fuel, air and sample. Electronic back-pressure regulator with sample bypass system ensures fast response. Discrete, multilevel concentration & fault alarms. Programmable relays for concentration alarms, events and diagnostics. Automatic FID ignition, with automatic shut-off of sample, fuel and combustion air. Remote operation via RS-232 and Ethernet. Graphical display and easy to use menu system. Optional 9000 Keeper software to monitor and control the instrument remotely.

8 Series 9000 H Heated Hydrocarbon Analyzer Analytical Detector: Flame ionization detector (FID). Sample Temperature: Up to 376 F (191 C). Ranges: User definable based upon calibration within: MDQ 0.3ppm, Full-scale 1 to 2,000ppm (Methane) MDQ 0.6ppm, Full-scale 1 20,000ppm (Methane) MDQ 0.003%, Full-scale % (Methane) Repeatability: +/- 1% Full-scale response. Drift: +/- 1% of Full-Scale over 24 hours. Response Time: T90 < 5 sec. Alarms: Multilevel concentration and fault alarms that result in audible and visual alarms. Alarms may also be mapped to relays to control external equipment. Sampling: Internal single module for pre-filtered (<0.1 microns), non-condensing samples, with or without sample pump. Calibration: Programmable automatic or manual calibration. Support Gas: Hydrogen 40 cc/min, Air 200 cc/min. (typical). Hydrocarbon content must be less than 1 ppm. Fuel blend options available, consult Baseline Physical Dimensions: (48.3cm) W x (36.2cm) D x 5.25 (13.3cm) H. Weight: < 25 lb (11.3kg). Configuration: Bench-top or rack-mount 19 (48.3cm) panel. Connections: 1/4 (6.35mm) tube fitting connectors. Operating Temperature: F (0-40 C). Operating Humidity: 0 95% (non-condensing). Electrical Power: VAC, 50/60Hz, 3A. Display: 3.4 (8.6cm) x 4.5 (11.4cm) graphical display. Relay Outputs: 5 programmable form A relays rated to 230V AC. Analog Outputs: 1 programmable 0-20mA or 4-20mA isolated output. Digital Outputs: RS-232, Ethernet. P.O. Box 649, Highway 36 Lyons, CO P: F: E: Sales@BaselineIndustries.com D025.3

9 Series 9000 Analyzer Versions Model 9000 THA 9000 NMHC 9000 H 9000 TCA Description Fully Automated Hydrocarbon Analyzer Methane / Non-Methane Hydrocarbons Fully Automated Heated Hydrocarbon Analyzer Total Carbon Analyzer (THC+CO+CO 2 in inert gases, except air & O 2 ) Detector FID FID with Oxidizer Catalyst FID FID with Methanizer Catalyst Sample Points 1 and 4 point 1 and 4 point 1 point 1 and 4 point Sampling Type 4 point is Sequential 4 point is Sequential Continuous 4 point is Sequential Outputs Standard: 5 relays, 1 analog, RS-232, Ethernet Optional: Additional 9 relays & 3 analogs Standard: 5 relays, 1 analog, RS-232, Ethernet Optional: Additional 9 relays & 3 analogs Standard: 5 relays, 1 analog, RS-232, Ethernet Standard: 5 relays, 1 analog, RS-232, Ethernet Optional: Additional 9 relays & 3 analogs Internal Wetted Parts Stainless Steel Stainless Steel Stainless Steel Stainless Steel Sample Temperature Ambient Ambient Up to 191 C (376 F) Ambient Repeatability Drift +/- 1% full scale +/- 1% full scale +/- 1% full scale +/- 1% full scale +/- 1% over 24 hours +/- 1% over 24 hours +/- 1% over 24 hours +/- 1% over 24 hours Gas Flow Control Electronic Electronic Electronic Electronic User selectable within: User selectable within: User selectable within: User selectable within: 0.01 to 100ppm 0.06 to 200ppm (Air balance) 0.3 to 2000ppm 0.1 to 100ppm Ranges & MDQ 0.1 to 2000ppm 0.1 to 1000ppm (Air balance) 0.6 to 20000ppm (as Methane) 0.3 to 20000ppm 0.03 to 200ppm (O 2 balance) 0.003% to 50% 0.003% to 100% Calibration Automatic or Manual Automatic or Manual Automatic or Manual Automatic or Manual Calibration Plumbing Optional: Internal Zero/Span Valves Optional: Internal Zero/Span Valves Optional: Internal Zero/Span Valves Optional: Internal Zero/Span Valves P.O. Box 649, Highway 36 Lyons, CO P: F: E: Info@BaselineIndustries.com D031.1

HFID Heated Total Hydrocarbon Analyzer Module

HFID Heated Total Hydrocarbon Analyzer Module Product Data Sheet PDS 103-685.A01 October, 2003 NGA 2000 HFID Heated Total Hydrocarbon Analyzer Module Heated analyzer designed to operate from 200 F to 400 F Eliminates loss of hydrocarbons due to condensation

More information

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels. Gas Chromatograph Continuous Analysis of Ultra High Purity Argon to ppb levels Features Following on from the success of the AGC Series 100 Argon GC, AGC Instruments introduces the new NovaCHROM 2000 GC.

More information

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased TELEDYNE Series 3300 Unaffected by hydrocarbons, H2, or CO2 Easy to handle, inexpensive, and easy to replace Can apply to ppb, ppm, and percent ranges Trace & Percent Oxygen Analyzers Fuel Cell Zirconium

More information

FIXED GAS ANALYZER (FGA)

FIXED GAS ANALYZER (FGA) Gas Chromatography FIXED GAS ANALYZER (FGA) Productivity remains the primary goal of most work environments. Utilizing a gas chromatographic system capable of performing multiple analyses on a series of

More information

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection Procedure No: SOP-020 Revision No: 1.0 (January 21, 2011) Page No.: 1 of 7 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting, and to

More information

A New Standard of Excellence

A New Standard of Excellence A New Standard of Excellence PREVENTION IS SO EASY... LIVING THROUGH A DISASTER IS NOT The reliable identification of low combustion oxygen in a fired heater or boiler has always been critical to the effectiveness

More information

Toxic Gas Detection. Model F12. Toxic Gas Detection

Toxic Gas Detection. Model F12. Toxic Gas Detection Toxic Gas Detection Model F12 Toxic Gas Detection Smart Sensor Technology The Series F12 Gas Transmitter is an Intrinsically Safe (IS) version of our explosion-proof D12 transmitter. In its standard form,

More information

Model D12-IR. Digital Gas Transmitter...

Model D12-IR. Digital Gas Transmitter... Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact

More information

Warranty Registration

Warranty Registration WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship and materials for a period

More information

Process Gas Chromatograph

Process Gas Chromatograph A I T Applied Instrument Technologies FXi Series5 PRODUCT SPECIFICATIONS Process Gas Chromatograph PSS FXI-S5 The FXi Series5 Process Gas Chromatograph (PGC) continuously analyzes, measures, and reports

More information

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry The «Modular Rack Gas Generators» Solution Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry With Unique Remote Control Monitoring

More information

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) PART 1 - GENERAL A. RELATED DOCUMENTS SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) Federal, State, and local requirements as applicable. Attached Permit Attached drawings B. SUMMARY 1. Provide

More information

CALIDUS tm the Modular micro Gas Chromatograph

CALIDUS tm the Modular micro Gas Chromatograph CALIDUS tm the Modular micro Gas Chromatograph Sample Processing Unit Plug & Play Programmed Temperature Column Modules Plug & Play Detector Modules Flame Ionization Thermal Conductivity A CALIDUS micro

More information

SAM-MAX Refrigerant Monitors

SAM-MAX Refrigerant Monitors SAM-MAX Refrigerant Monitors Monitor Refrigerants Including CFCs, HFCs and Ammonia Monitor Carbon Monoxide Exceeds ASHRAE 5-99 and USEPA 608 Monitoring Requirements Provide for Single or Multipoint Sampling

More information

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples Process and Air Monitoring Online GC systems for continuous monitoring of organic compounds in air and gaseous samples For 35 years AMA Instruments has developed and manufactured analytical devices and

More information

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS Product Information GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS Gas Analyzers SOLUTION FOR CONTINUOUS HYDROCARBON MEASUREMENTS The compact GMS800 FIDOR extractive

More information

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring. Water Quality Labo- Soil/ Soil/ Sedi- Sam- & Air / Dust Toxic gases are present in a wide variety of industrial and civil installations and their detection and monitoring is crucial for the safe working

More information

Recent Improvements in Process GC Instrumentation

Recent Improvements in Process GC Instrumentation ISA Houston, TX Oct., 15 2003 Recent Improvements in Process GC Instrumentation Dr. Jack Driscoll PID Analyzers, LLC copyright 2000-2006 PID Presentation Objectives A new Process GC has been developed

More information

931D Style B Process Gas Chromatograph

931D Style B Process Gas Chromatograph Product Specifications PSS 6-4N1 D 931D Style B Process Gas Chromatograph The new 931D Style B Process Gas Chromatograph continuously analyzes, measures and reports the concentration of components in process

More information

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011 MICHELL GROUP Advanced Industrial Hygrometry and Process Instrumentation Company Profile, 2011 Who is the Michell Group? Leading in the world of solutions for humidity and gas analysers More than 30 years

More information

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display. Sheet No. 1 of 4 monitor/analyzer with alarm and Graphical Display. Sheet No. 2 of 4 It specially designed to analyze any gas of your choice, its automatic operation, accurate measurement and crystal clear

More information

Tri-Tech Medical Inc.

Tri-Tech Medical Inc. Submittal Data Sheet Project Information Project Number Approval Features The Tri-Tech Area and Master Alarm Panel digitally displays gas pressure (1 psi increments) monitors and displays normal and alarm

More information

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES USER INSTRUCTIONS FOR THE CHEMGARD INFRARED GAS MONITOR SERIES To completely customize the specification to your exact application, modification to the

More information

Monitoring Flammable Vapors and Gases in Industrial Processes

Monitoring Flammable Vapors and Gases in Industrial Processes Monitoring Flammable Vapors and Gases in Industrial Processes Flammability Hazards Industrial fires and explosions happen more frequently than most people think. They cause downtime, property damage, injury

More information

ALTAIR 5X Multigas Detector Product Specification

ALTAIR 5X Multigas Detector Product Specification ALTAIR 5X Multigas Detector Product Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Weight Handling Case material Environmental protection Display

More information

SIL 2. Ultima X Series Gas Monitors CERTIFIED

SIL 2. Ultima X Series Gas Monitors CERTIFIED Ultima X Series Gas Monitors 5 Now with SIL 2 CERTIFIED Products Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection

More information

Complete Gas Analysis

Complete Gas Analysis Complete Gas Analysis A complete range of gas analysers, systems and accessories for emissions, air quality, research and process monitoring. The Signal Group, incorporating the gas analysis business of

More information

ULTIMA X5000. MSAX5000.com

ULTIMA X5000. MSAX5000.com ULTIMA X5000 MSAX5000.com WE KNOW YOU RE TIRED OF... NEEDING TO DISCONNECT POWER BEFORE CHANGING A SENSOR REMEMBERING HOW TO CALIBRATE THIS THING HAVING TO PULL SO MUCH WIRE AT EVERY GAS DETECTOR INSTALLATION...

More information

Frequently Asked Questions

Frequently Asked Questions 1. 2. What advantages does the GT3000 have over the C7064? Hot swappable GTS sensor module is intrinsically safe and allows live maintenance under power Supports HART communication Supports local, one-person

More information

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors Ultima X Series Gas Monitors Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection methods. HART Protocol is now

More information

Gas Detection - GD -

Gas Detection - GD - s Gas Detection TECHNICAL SPECIFICATIONS Gas Detection DATA SHEE - GD - Continuing development sometimes necessitates specification changes without notice Technical Specifications 2008 GD-00 Gas Measuring

More information

Med Touch Combination Alarm Conversion Kits

Med Touch Combination Alarm Conversion Kits Submittal Data Sheet Features The Powerex Combination Alarm Panel conversion kits are designed to upgrade or retro-fit existing panels produced by several major brands. The conversion kit replaces all

More information

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger

More information

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314) Mass Sensors, Inc. 1350 Baur Blvd, St. Louis, MO 63132 (314) 997-5779 www.mass-sensors.com Innovations in chemical microsensors Profile Mass Sensors is a development stage high-tech company operating in

More information

MSA Fixed Gas & Flame Detection for the Automotive Industry

MSA Fixed Gas & Flame Detection for the Automotive Industry MSA Fixed Gas & Flame Detection for the Automotive Industry A Passion for Safety Automotive facilities may be comprised of research and development laboratories, and engine testing and environmental chambers.

More information

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES PROCESS ANALYZERS DF-340E The DF-340E is a Coulometric sensor based oxygen analyzer suitable for outdoor installation and designed to measure trace oxygen and percent level in pure and multigas backgrounds.

More information

CS744 Series: Carbon/Sulfur by Combustion

CS744 Series: Carbon/Sulfur by Combustion CS744 Series: Carbon/Sulfur by Combustion Delivering the Right Results CS744 Series: Carbon/Sulfur by Combustion LECO's CS744 Series will redefine the way you determine carbon and sulfur in primary steels,

More information

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca.

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca. Monitoring Parameter: Methane and Non-Methane Hydrocarbons Revision No: Draft Revision Date: 09 April, 2018 Title: Standard Operating Procedure for the Non-Continuous Measurement of Ambient Methane and

More information

Selecting the right generator for your GC system. By Ed Connor, GC Product Specialist, Peak Scientific Instruments Ltd

Selecting the right generator for your GC system. By Ed Connor, GC Product Specialist, Peak Scientific Instruments Ltd Selecting the right generator for your GC system By Ed Connor, GC Product Specialist, Peak Scientific Instruments Ltd Selecting the right generator for your GC system Gas generators offer a guaranteed

More information

Products and performance

Products and performance Products and performance February 26, 2016 GfG Instrumentation overview of fixed system products Slide 1 GfG Instrumentation, Inc. 1194 Oak Valley Drive, Suite 20, Ann Arbor, Michigan 48108 Toll free (USA

More information

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device Featuring an ergonomic design and innovative infrared sensor technology, the Dräger X-am 5600 is the smallest gas detection instrument for the

More information

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6 Digital Gas Transmitters with Auxiliary s & Control Specifications subject to change without notice. USA 181011 Page 1 of 5 DESCRIPTION Digital RS-485 communicating, addressable toxic and combustible gas

More information

Constant climate chambers

Constant climate chambers KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors

More information

Mercury Vapor Monitor VM-3000

Mercury Vapor Monitor VM-3000 Member of the envea Group Mercury Vapor Monitor VM-3000 Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Proven reliable detection method: UV absorption (CVAAS)

More information

White paper on the Dielectric Barrier Discharge Detectors. Introduction:

White paper on the Dielectric Barrier Discharge Detectors. Introduction: White paper on the Dielectric Barrier Discharge Detectors. Introduction: This paper is a discussion of the dielectric barrier discharge detector. As such, it is intended to provide insight into the operating

More information

INSTRUCTION, OPERATING AND MAINTENANCE MANUAL FOR MODEL

INSTRUCTION, OPERATING AND MAINTENANCE MANUAL FOR MODEL INSTRUCTION, OPERATING AND MAINTENANCE MANUAL FOR MODEL 4040 P/N M78485 05/18/2015 DANGER Toxic and/or flammable gases or liquids may be present in this monitoring system. Personal protective equipment

More information

Dew-Point Transmitters and Instruments

Dew-Point Transmitters and Instruments Dew-Point Transmitters and Instruments Reliable moisture measurement for critical process control Moisture Measurement and Analysis Michell Instruments sensors provide accurate and reliable moisture measurement

More information

SERVOMEX PRODUCT GUIDE

SERVOMEX PRODUCT GUIDE SERVOMEX PRODUCT GUIDE OUR INDUSTRY-LEADING ANALYZER RANGE AND SYSTEMS, MATCHED TO YOUR INDUSTRY REQUIREMENTS POWER GENERATION HYDROCARBON ING SPECIALIST S METALS & MINING INDUSTRIAL ES P3 GET THE FULL

More information

VM-3000 Mercury Vapor Monitor

VM-3000 Mercury Vapor Monitor MERCURY INSTRUMENTS ANALYTICAL TECHNOLOGIES VM-3000 Mercury Vapor Monitor Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Portable, integrated battery for 6 hours

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable

More information

Thermo Scientific TVA2020 Introduction

Thermo Scientific TVA2020 Introduction Thermo Scientific TVA2020 Introduction The Thermo ScientificT TVA2020 Toxic Vapor Analyzer, is an advanced design, portable, organic/inorganic vapor monitor for the gas survey industry. The analyzer uses

More information

VM-3000 Mercury Vapor Monitor

VM-3000 Mercury Vapor Monitor MERCURY INSTRUMENTS Analytical Technologies VM-3000 Mercury Vapor Monitor Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Proven reliable detection method: UV absorption

More information

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility EAGLE 2 Inlet fitting Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility Internal / external hydrophobic filters Self healing polyurethane protective

More information

EuroFID Gas Analyzers for Measurement of the Total Hydrocarbon Content

EuroFID Gas Analyzers for Measurement of the Total Hydrocarbon Content Front page OPERATING INSTRUCTIONS EuroFID Gas Analyzers for Measurement of the Total Hydrocarbon Content Installation Operation Maintenance Document Information Described Product Product name: EuroFID

More information

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR SAFETY MANUAL SIL 2 Certified Model FP-700 Combustible Hydrocarbon Gas Sensor Version 2.0 1 SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR This manual addresses the specific requirements and recommendations

More information

Sieger Apex. Flexibility that meets your requirements

Sieger Apex. Flexibility that meets your requirements Sieger Apex Flexibility that meets your requirements Sieger Apex Easy to Install Sensor can be remotely mounted up to 100m from the transmitter On board relays allow for local audible/ visual alarms Strong

More information

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.

More information

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability GasSens Modular Gas Detector... Self Checking Gas Sensors GasSens is a flexible component system providing a variety of options to meet individual gas detection and alarm requirements. From chemical and

More information

Operation and Maintenance Manual

Operation and Maintenance Manual Operation and Maintenance Manual GDS-48 Remote Bridge Sensor for Combustible Gases AUTHORIZED DISTRIBUTOR: GasDetectorsUSA.com - Houston, Texas USA sales@gasdetectorsusa.com - 832-615-3588 CAUTION: FOR

More information

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation Gas Detection Control Panel Analog and digital controller 4 or 8 lines / 6 to detectors max Highly versatile controller Cost savings on wiring installation Certifications The The Fixed Fixed Gas Gas Detection

More information

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head 4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.

More information

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Carbon Monoxide (CO) Gas Detector March 15 GCO 300 GCO Carbon Monoxide (CO) Gas Detector March 15 Features Output 4-20 ma or 2-10 Vdc Power supply 24 Vdc Ranges 0-100 ppm or 0-300 ppm IP65 enclosure with quick locking screws Digital measurement value processing

More information

Dräger X-am 7000 Multi-Gas Detection

Dräger X-am 7000 Multi-Gas Detection Dräger X-am 7000 Multi-Gas Detection Dräger X-am 7000 is the solution for the simultaneous and continuous measurement of up to five gases. It is the ideal companion in a variety of applications where the

More information

Recalibrate the way you look at gas detection

Recalibrate the way you look at gas detection Catalogue Gas detection solution Recalibrate the way you look at gas detection Next generation gas detection for industrial refrigeration The next generation of Danfoss gas detectors are based on a digital

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET S p e c i f i c a t i o n WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700 D e t e c t o r C o n t r o l P a n e l Wall mounting 24V DC or 110/230vAC operation

More information

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety GDS Corp gas monitors, controllers and sensors satisfy today s needs for safety and reliability in critical gas detection

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation Gas Detection Control Panel MX Analog and digital controller or 8 lines / 6 to s max Highly versatile controller Cost savings on wiring installation The Fixed Gas Detection People www.oldhamgas.com an

More information

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance Combustible and Toxic Gas Detection Solutions Performance and Safety Beyond Compliance Reliable Solutions from Det-Tronics, Your Partner in Safety Trusted Response with the Utmost Confidence Our proven

More information

Constant climate chambers

Constant climate chambers KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.

More information

S5000 Gas Monitor. GMS5000.com

S5000 Gas Monitor. GMS5000.com S5000 Gas Monitor GMS5000.com A DETECTOR AS TOUGH AS YOU ARE... LOWER TEMPERATURE SPEC?... ARCTIC WINTERS IT HAS TO BE THE MOST RELIABLE PIECE OF EQUIPMENT OUT HERE IF THE DETECTOR DOESN T WORK, WE DON

More information

T.ex Single Gas Detector VISA

T.ex Single Gas Detector VISA T.ex Single Gas Detector The T.ex is newest instrument in the Promat portfolio. The instrument is currently available in Oxygen, Hydrogen Sulphide and Carbon Monoxide versions. A Bump Test Station is available

More information

POPULAR CONFIGURATION GCs Cryosulfur GC. System Overview

POPULAR CONFIGURATION GCs Cryosulfur GC. System Overview System Overview The SRI CryoSulfur GC comes with everything you need to detect low-level sulfur compounds in gas samples. Since some sulfur compounds do not trap well, the CryoSulfur GC uses the CryoCooler

More information

PUV, PIR and PFO Series BROCHURE

PUV, PIR and PFO Series BROCHURE PUV, PIR and PFO Series BROCHURE JUNHO 2013 ABB Multiwave TM process photometers PUV3402, PIR3502 and PFO3372 Measure vapor and liquid samples in IR, NIR, UV and VIS regions Process photometers PUV3402,

More information

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer. The Process TDLS Solution New Features TDLS 200 Tunable Diode Laser Spectroscopy (TDLS) Analyzer Bulletin 11Y01B01-01E-A www.yokogawa.com/an/index.htm The first Tunable Diode Laser analyzer Innovative

More information

Analyze IT. Process Gas Chromatograph. PGC2000 Series

Analyze IT. Process Gas Chromatograph. PGC2000 Series Process Gas Chromatograph PGC2000 Series PGC2000 Series PGC2002 Process Distillation PGC2003 PNA PGC2005 Temperature Programmed GC PGC2007 Fuel Sulfur Analyzer PGC2008 Olefins Analyzer PGC2009 Fast TP

More information

GAS ANALYSIS / DETECTION Gas Detector

GAS ANALYSIS / DETECTION Gas Detector Eikon - Single gas recyclable personal monitor GAS ANALYSIS / DETECTION Tough and rugged Eikon is the durable single gas fixed life personal monitor that really lasts the course. Loud & Clear Alarms Easy

More information

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm Oxygen Deficiency Monitor and Oxygen Analyzers Oxygen Sensors for 0-25% and 0-1000ppm ABOUT PUREAIRE MONITORING SYSTEMS PureAire is an experienced safety gas detection manufacturer providing long lasting

More information

Constant climate chambers

Constant climate chambers KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.

More information

Trace Moisture Analyzer for Inert, Passive,Toxic, and Corrosive Gases

Trace Moisture Analyzer for Inert, Passive,Toxic, and Corrosive Gases Trace Moisture Analyzer for Inert, Passive,Toxic, and Corrosive Gases THE TIGER S TALE Tiger Optics is proud to announce a significant advance in moisture measurement for UHP inert, toxic, and corrosive

More information

Process Gas Chromatograph

Process Gas Chromatograph Product Data Sheet PDS 103-1000.A01 December 2005 Model 1000 Process Gas Chromatograph Emerson Process Management offers a complete line of gas chromatographs specifically designed for process applications.

More information

Process Gas Chromatograph

Process Gas Chromatograph Product Data Sheet RAI-PDS-GC-1000A June 2009 Model 1000A Process Gas Chromatograph Emerson Process Management offers a complete line of gas chromatographs specifically designed for process applications.

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the 3000HM Flame Ionisation Detector 3010 & 3030 Portable Flame Ionisation Detector manufactured by: Signal Group Ltd 12 Doman Road Camberley Surrey,

More information

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary

More information

SERIES 4030 HEATED THC

SERIES 4030 HEATED THC INSTRUCTION, OPERATING AND MAINTENANCE MANUAL FOR SERIES 4030 HEATED THC P/N M77216 DATE 5/18/15 DANGER Toxic and/or flammable gases or liquids may be present in this monitoring system. Personal protective

More information

Constant climate chamber with humidity

Constant climate chamber with humidity KBF series (E5.2) Constant climate chambers Constant climate chamber with humidity The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate

More information

Datalogging as standard

Datalogging as standard Datalogging as standard for expanded performance Autofim II and Autofim II GC have a sophisticated datalogging system, as standard, which enables you to keep a permanent data record. The memory is capable

More information

IGD.CO.UK

IGD.CO.UK APPLICATION DATA SHEET S p e c i f i c a t i o n 2 SO22 WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700+ D e t e c t o r Website: C o n t r o l P a n e l - Wall mounting or 19 Rack

More information

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com Model GD-3300 Combustible Gas Leak Detector Instruction Manual reedinstruments com Introduction The Combustible Gas Leak Detector has a 16 gooseneck probe to find leaks in hard-to-reach areas. It s adjustable

More information

MODEL 1925-PR TRITIUM HEAVY WATER LEAK DETECTOR

MODEL 1925-PR TRITIUM HEAVY WATER LEAK DETECTOR This monitor has been designed for real time low-level detection of tritium in water in the industrial environment of nuclear power plants. Low MDA, reliability, ruggedness (suitable for HWR, PWR, BWR)

More information

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor... Improve Performance and Reduce Maintenance Costs Model Q45D Dissolved Oxygen Monitor... Why Throw Away Money? Why Throw Away Money? ATI s Model Q45D Dissolved Oxygen monitor is designed to provide reliable

More information

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots 5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots GX-6000 5 Operating modes Normal Leak Check Inert Bar hole Snap Log Monitor up to

More information

EXAMPLES OF HOW TO ORDER

EXAMPLES OF HOW TO ORDER E 3 Point PRODUCT SUBMITTAL Toxic and Combustible Gas Detector Standalone Platform (Single or Dual-Gas Monitoring) ORDERING INFORMATION Single-Gas or Dual-Gas Configuration: Base Unit, Surface-Mount Base

More information

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots 5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots CONFINED SPACE ENTRY Monitor LEL, O2, CO, and H2S Internal sample pump Pull samples

More information

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM User Instructions For The Model 5200 Gas Monitor System To completely customize the specifications to your exact application, modifications to the following

More information

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics 4000TOC Sensor THORNTON Leading Pure Water Analytics 4000TOC Sensor Fast, continuous measurements No reagents or chemicals needed No moving parts Meets USP 643, 645,Ch P, EP 2.2.44, and JP requirements

More information

Model D12. Digital Gas Transmitter

Model D12. Digital Gas Transmitter Model D12 Digital Gas Transmitter Gas detection systems come in all shapes and sizes. Some require simple 4-20 ma transmission. Some are better suited to local alarm relay functions. Some really require

More information

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel Gas Detection Control Panel MX Analog and digital controller or 8 lines / 6 to s max Highly versatile controller SIL reliability Fixed The Fixed Gas Gas Detection Detection Experts People www.oldhamgas.com

More information

Rosemount Analytical Solutions. Emerson Offshore Technology Day March 26th 2015 by Rune Damgaard, Account Manager - Measure & Analyze

Rosemount Analytical Solutions. Emerson Offshore Technology Day March 26th 2015 by Rune Damgaard, Account Manager - Measure & Analyze Rosemount Analytical Solutions Emerson Offshore Technology Day March 26th 2015 by Rune Damgaard, Account Manager - Measure & Analyze Innovation applied to Offshore Applications Well head analysis Process

More information