Fire Safety. Installation Instructions Model NIM-1W Network Interface Module MXL NETWORK INTERFACE APPLICATIONS OPERATION NIM-1W

Size: px
Start display at page:

Download "Fire Safety. Installation Instructions Model NIM-1W Network Interface Module MXL NETWORK INTERFACE APPLICATIONS OPERATION NIM-1W"

Transcription

1 Fire Safety Installation Instructions Model NIM-W Network Interface Module MXL NETWORK INTERFACE APPLICATIONS OPERATION The SIEMENS Model NIM-W provides a new communication path for the following uses: as an MXL networking interface as a connection to Foreign Systems as a connection to Air Sampling detectors When used as a networking interface the NIM-W supports the connection of up to 6 MXL Systems. This new network also supports a Network Command Center (NCC) that monitors all the MXLs in the networked group. Output logic between MXL panels is done using CSG-M programming. CSG-M versions 6.0 and higher include options for networked MXL Systems. Each MXL System is assigned a panel number. This panel number allows interactive programming between panels using CSG-M. INSTALL JUMPER PLUGS IN ORIENTATION AS SHOWN. POSITION M SHOWN SELECTED. M W The NIM-W supports both Style 4 and Style 7 connection. In the event of an NIM-W communication failure, each MXL System continues to operate as a standalone panel. The NIM-W can also be configured as an RS-485 two wire interface to foreign systems. This operation is called FSI (Foreign System Interface). The FSI responds to a protocol and gathers information about the MXL status. The interface supports both single MXL Systems and networked systems. Typical use of this interface is between the MXL and building management systems. Use the CSG-M to enable the functions accessed by the foreign system. If the foreign system is UL 864 listed with the MXL, the interface can also be enabled to support control of the MXL including the commands to acknowledge, silence, and reset. For configurations that require both MXL networking and a foreign system interface, two NIM-W boards are required in the MXL System supporting the foreign system interface. JP M W 5 JP4 JP2 NIM-W JP SW2 SW D4 ANY TRBL D5 ANY ENABLE P6 5 + W X D8 XMIT Siemens Building Technologies, Inc. 8 Fernwood Road Florham Park, New Jersey 0792 Figure NIM-W Module Board W X P6 INSTALL JUMPER PLUGS IN ORIENTATION AS SHOWN. POSITION X SHOWN SELECTED. Siemens Building Technologies, Ltd. 2 Kenview Boulevard Branpton, Ontario L6T 5E4 CN P/N

2 TABLE NETWORK ADDRESS PROGRAMMING (SW) ADDR ADDR ADDR ADDR ILLEGAL 064 OXOOOOOO 28 XOOOOOOO 92 XXOOOOOO 00 ILLEGAL 065 OXOOOOOX 29 XOOOOOOX 9 XXOOOOOX 002 ILLEGAL 066 OXOOOOXO 0 XOOOOOXO 94 XXOOOOXO OOOOOOXX OOOOOXOO OOOOOXOX OOOOOXXO OOOOOXXX OOOOXOOO OOOOXOOX OOOOXOXO OOOOXOXX OOOOXXOO OOOOXXOX OOOOXXXO OOOOXXXX OOOXOOOO OOOXOOOX OOOXOOXO OOOXOOXX OOOXOXOO OOOXOXOX OOOXOXXO OOOXOXXX OOOXXOOO OOOXXOOX OOOXXOXO OOOXXOXX OOOXXXOO OOOXXXOX OOOXXXXO OOOXXXXX OOXOOOOO OOXOOOOX OOXOOOXO OOXOOOXX OOXOOXOO OOXOOXOX OOXOOXXO OOXOOXXX OOXOXOOO OOXOXOOX OOXOXOXO OOXOXOXX OOXOXXOO OOXOXXOX OOXOXXXO OOXOXXXX OOXXOOOO OOXXOOOX OOXXOOXO OOXXOOXX OOXXOXOO OOXXOXOX OOXXOXXO OOXXOXXX OXOOOOXX OXOOOXOO OXOOOXOX OXOOOXXO OXOOOXXX OXOOXOOO OXOOXOOX OXOOXOXO OXOOXOXX OXOOXXOO OXOOXXOX OXOOXXXO OXOOXXXX OXOXOOOO OXOXOOOX OXOXOOXO OXOXOOXX OXOXOXOO OXOXOXOX OXOXOXXO OXOXOXXX OXOXXOOO OXOXXOOX OXOXXOXO OXOXXOXX OXOXXXOO OXOXXXOX OXOXXXXO OXOXXXXX OXXOOOOO OXXOOOOX OXXOOOXO OXXOOOXX OXXOOXOO OXXOOXOX OXXOOXXO OXXOOXXX OXXOXOOO OXXOXOOX OXXOXOXO OXXOXOXX OXXOXXOO OXXOXXOX OXXOXXXO OXXOXXXX OXXXOOOO OXXXOOOX OXXXOOXO OXXXOOXX OXXXOXOO OXXXOXOX OXXXOXXO OXXXOXXX XOOOOOXX XOOOOXOO XOOOOXOX XOOOOXXO XOOOOXXX XOOOXOOO XOOOXOOX XOOOXOXO XOOOXOXX XOOOXXOO XOOOXXOX XOOOXXXO XOOOXXXX XOOXOOOO XOOXOOOX XOOXOOXO XOOXOOXX XOOXOXOO XOOXOXOX XOOXOXXO XOOXOXXX XOOXXOOO XOOXXOOX XOOXXOXO XOOXXOXX XOOXXXOO XOOXXXOX XOOXXXXO XOOXXXXX XOXOOOOO XOXOOOOX XOXOOOXO XOXOOOXX XOXOOXOO XOXOOXOX XOXOOXXO XOXOOXXX XOXOXOOO XOXOXOOX XOXOXOXO XOXOXOXX XOXOXXOO XOXOXXOX XOXOXXXO XOXOXXXX XOXXOOOO XOXXOOOX XOXXOOXO XOXXOOXX XOXXOXOO XOXXOXOX XOXXOXXO XOXXOXXX XXOOOOXX XXOOOXOO XXOOOXOX XXOOOXXO XXOOOXXX XXOOXOOO XXOOXOOX XXOOXOXO XXOOXOXX XXOOXXOO XXOOXXOX XXOOXXXO XXOOXXXX XXOXOOOO XXOXOOOX XXOXOOXO XXOXOOXX XXOXOXOO XXOXOXOX XXOXOXXO XXOXOXXX XXOXXOOO XXOXXOOX XXOXXOXO XXOXXOXX XXOXXXOO XXOXXXOX XXOXXXXO XXOXXXXX XXXOOOOO XXXOOOOX XXXOOOXO XXXOOOXX XXXOOXOO XXXOOXOX XXXOOXXO XXXOOXXX XXXOXOOO XXXOXOOX XXXOXOXO XXXOXOXX XXXOXXOO XXXOXXOX XXXOXXXO XXXOXXXX XXXXOOOO XXXXOOOX XXXXOOXO XXXXOOXX XXXXOXOO XXXXOXOX XXXXOXXO XXXXOXXX 056 OOXXXOOO 20 OXXXXOOO 84 XOXXXOOO 248 ILLEGAL 057 OOXXXOOX 2 OXXXXOOX 85 XOXXXOOX 249 ILLEGAL 058 OOXXXOXO 22 OXXXXOXO 86 XOXXXOXO 250 ILLEGAL 059 OOXXXOXX 2 OXXXXOXX 87 XOXXXOXX 25 ILLEGAL 060 OOXXXXOO 24 OXXXXXOO 88 XOXXXXOO 252 ILLEGAL 06 OOXXXXOX 25 OXXXXXOX 89 XOXXXXOX 25 ILLEGAL 062 OOXXXXXO 26 OXXXXXXO 90 XOXXXXXO 254 ILLEGAL 06 OOXXXXXX 27 OXXXXXXX 9 XOXXXXXX 255 ILLEGAL O = OPEN (or OFF) X = CLOSED ( or ON) 2

3 TABLE 2 PANEL NUMBER PROGRAMMING (SW2) ADDR ADDR ADDR ADDR ROOOOOOO SOOOOOOX SOOOOOXO SOOOOOXX SOOOOXOO SOOOOXOX SOOOOXXO SOOOOXXX SOOOXOOO SOOOXOOX SOOOXOXO SOOOXOXX SOOOXXOO SOOOXXOX SOOOXXXO SOOOXXXX SOOXOOOO SOOXOOOX SOOXOOXO SOOXOOXX SOOXOXOO SOOXOXOX SOOXOXXO SOOXOXXX SOOXXOOO SOOXXOOX SOOXXOXO SOOXXOXX SOOXXXOO SOOXXXOX SOOXXXXO SOOXXXXX SOXOOOOO SOXOOOOX SOXOOOXO SOXOOOXX SOXOOXOO SOXOOXOX SOXOOXXO SOXOOXXX SOXOXOOO SOXOXOOX SOXOXOXO SOXOXOXX SOXOXXOO SOXOXXOX SOXOXXXO SOXOXXXX SOXXOOOO SOXXOOOX SOXXOOXO SOXXOOXX SOXXOXOO SOXXOXOX SOXXOXXO SOXXOXXX SOXXXOOO SOXXXOOX SOXXXOXO SOXXXOXX SOXXXXOO SOXXXXOX SOXXXXXO SOXXXXXX SXOOOOOO S = Closed selects Style 7 S = Open selects Style 4 O = Open or OFF X = Closed or ON R = Closed selects AnaLASER R = Open selects FSI NOTE: To open a dipswitch, press down on the side of the dipswitch marked OPEN. To close a dipswitch, press down on the side of the dipswitch opposite the side marked OPEN. To open a slide switch, push the slide to the side opposite the side marked ON. To close a slide switch, push the slide to the side marked ON. The NIM-W also provides for the connection of up to Air Sampling detectors. The MXL supports individual programming and monitoring of the Air Sampling devices. Each detector can be uniquely programmed from the MKB menu or by using CSG-M. All three alarm levels (PreAlarm, PreAlarm 2, and Alarm) are supported. NOTE: When the NIM-W is configured as an Air Sampling interface, it cannot support either MXL networking or the FSI. If these functions are required, additional NIM-Ws must be used. INSTALLATION Remove all system power before installation, first battery and then AC. (To power up, connect the AC first, then the battery.) The NIM-W installs into the MXL optional /2 card cage where it occupies one full width slot. The NIM-W can be installed in either of the full slots of the /2. The slot determines if the wiring is connected to TB or TB4 of the /2. Setting the Switches Set all switches, configuration jumpers, and connection cables before installing the NIM-W into the. Use switch SW to set the MXL network address. Set this switch according to the address where the NIM-W is installed in the MXL s network map. Refer to the CSG-M configuration printout for the address of the module. See Table for settings. Use switch SW2 to set either the panel number for networked systems or to select FSI or Air Sampling operation. Refer to Table 2 for panel settings, Table for FSI settings, and Table 4 for Air Sampling settings.. When installing the NIM-W in a networked system, set the panel number to agree with the panel number for the NIM-W assigned to the MXL System in CSG-M. 2. Switch position 8 selects Style 4 or Style 7 operation for the NIM-W network.. Set jumper plugs on JP4 to the "M" position. Set jumper plugs on P6 to the "X" position.

4 * NETWORK PAIR B SUPERVISED (OMIT FOR STYLE 4) EOLR 20 OHMS, /4W P/N CABLE P/N TO MMB OR PSR- EOLR 20 OHMS, /4W P/N NETWORK PAIR A SUPERVISED SEE FIGURE CABLE P/N TO MMB OR PSR- SEE FIGURE TB TB TB TB P NIM-R P NIM-R INSTALLED IN MXL PANEL INSTALLED IN MXL PANEL 2 P2 P4 P2 P4 TB TB4 TB TB4 * REQUIRED IN CANADIAN INSTALLATIONS EOLR 20 OHMS, /4W P/N CABLE P/N TO MMB OR PSR- TB TB2 P EOLR 20 OHMS, /4W P/N SEE FIGURE TB P NIM-R INSTALLED IN MXL PANEL P4 TB SEE NOTE 9 NIC-C (IF USED) ONE SLOT OF CC Figure 2 NIM-W Network Wiring Diagram NOTES:. 8 AWG minimum ohms maximum per pair.. Use shielded twisted pair. 4. Terminate the shield at MXL Panel only. 5. Power limited to NFPA 70 per NEC Maximum voltage 8V peak to peak. 7. Maximum current 50mA. 8. For Style 4 omit all Network Pair B connections. 9. CC-5 terminals 9-4 are not connected and can be used to tie shields together. 0. Refer to Wiring Specification for MXL, MXL-IQ and MXLV Systems, P/N revision 6 or higher, for additional wiring information. 4. When installing the NIM-W for FSI operation, set the switch to all open (or OFF). TABLE FSI PROGRAMMING ADDR FSI OOOOOOOO O = Open or OFF 5. When installing the NIM-W for Air Sampling detection connection, set the switch as follows: AIR TABLE 4 SAMPLING PROGRAMMING After setting the switches, install the NIM-W into the /2 card cage. Make sure that the module is in the card guides and the card edge is firmly seated in the connectors on the /2. CAUTION At all times handle all plug-in cards with extreme care. When inserting or removing a card, be sure the position of the card is kept at right angles to the board. Otherwise, the plug-in card can damage or displace other components. ADDR Air Sampling O = Open or OFF X = Closed or ON XOOOOOOO 4

5 ELECTRICAL CONNECTIONS NIM-W Network Figure 2 shows the wiring diagram for the NIM-W network. Up to 2 MXL Systems can be connected in the network with an NIM-W installed in each MXL System. For the highest level of fault protection, install the NIM-W in the enclosure with the MMB, although this is not necessary. When connecting more than 2 MXL Systems, an REP- repeater or D200CP is required. Refer to the REP- Installation Instructions, P/N , or the D200CP Installation Instructions, P/N , as applicable, for the wiring diagram. The network can be installed as either Style 4 or Style 7. Figure 2 shows which wires must be added to support Style 7. Style 7 is required in Canada. Each NIM-W is shipped with two 20 ohm EOLRs only two are required for each network pair. Install an EOLR at the ends of each network pair. Do not install an EOLR at each NIM-W. (For a simple rule of thumb, an EOLR must be installed where only a single wire lands on a screw terminal.) Do not T-tap the network wiring. If T-tapping is required, use the REP- repeater. Refer to the REP- Installation Instructions, P/N , or the D200CP Installation Instructions, P/N , as applicable, for the wiring diagram. For Style 4 wiring, terminate the secondary network pair (terminals and 4) on each NIM-W with an EOLR. Network Command Center (NCC) Figure shows the wiring to the NCC. To connect the NCC, observe the following restrictions:. Give the NCC a panel number. (This panel number is in addition to the panel number for the MXL System that the NCC connects to.) 2. The total number of panels in the network must not exceed 64, including the NCC SEE NOTE 9 NIC-C (IF USED) ONE SLOT OF CC NOTES:. 8 AWG minimum ohms max per pair.. Use twisted pair or shielded twisted pair. 4. Terminate the shield at one and only one NCC-F or NIM-W. 5. Power Limited to NFPA 70 per NEC Maximum voltage 8V P-P. 7. Maximum current 90mA. 8. Each pair independently supervised. 9. CC-5 terminals 9-4 are not connected and can be used to tie shields together. NCC-F 6 5 MXL TB2 TB NIM-W P5 P P0 TB4 TB IRQ JP A B JP2 C D J COM JP JP2 IRQ A C 4 2 A D B C 4 4 B D ** 4 2 SHIELD SHIELD ** LINE BALANCE RESISTOR 20 OHMS, /2W, 5% P/N To MMB, SMB OR PSR- To MMB, SMB OR PSR- SHIELD SHIELD Figure Connecting the NIM-W to the NCC and FireFinder-XLS 5

6 Foreign System Interface (FSI) The FSI installs on TB or TB4, terminals and 2, of the /2 depending on where the NIM-W is installed, as shown in Figure 4. Use one of the EOLRs provided with the NIM-W on terminals and 2. This properly terminates the FSI. Use the second EOLR on terminals and 4. Never use terminals and 4 to connect to the FSI. Refer to Figure 4 for the polarity of the FSI driver. If multiple FSI connections are required, up to four NIM-Ws may be installed in an individual MXL System. In networked systems each MXL can support up to four FSI ports. For networked systems, each FSI port must be configured as either local or global in the CSG-M. Local FSI ports display information only on the MXL System to which they are connected. Global FSI ports display all events in all MXL Systems. Refer to the CSG-M Manual, P/N , for further information. Air Sampling Interface AnaLASER Interface The AnaLASER Air Sampling interface connects to the /2, TB or TB4, terminals and 2, depending on where the NIM-W is installed (Refer to Figure 5). Up to Air Sampling detectors can be connected to a single NIM-W. The ACC- requires an RS-485 to RS-22 converter which mounts in the back of the ACC- enclosure. The converter model number is AIC-4Z. The AIC-4Z supports from one to four AnaLASER detectors. Refer to the AIC-4Z Installation Instructions, P/N , for the mounting and configuration of the converter and the ACC-s. Complete wiring of the converter as shown in Figure 5 before installing the ACC- in the enclosure. Place the end-of-line resistors in the locations specified in Figure 5. Install the cable P/N IC-2 between the converter and the ACC-. Refer to the AnaLASER Air Sampling Smoke Detection Manual, P/N , for connection to the AnaLASER detector and power supply, as well as mechanical mounting of the ACC-. NOTES:. 8 AWG minimum ohms maximum per pair.. Use shielded twisted pair. 4. Terminate the shield at the NIM-W enclosure only. 5. Power limited to NFPA 70 per NEC Maximum voltage 8V peak to peak. 7. Maximum current 50mA. 8. Refer to Wiring Specification for MXL, MXL-IQ and MXLV Systems, P/N revision 6 or higher, for additional wiring information. EOLR 20 OHMS, /2W P/N CABLE P/N TO MMB, SMB OR PSR- SUPERVISED _ + EOLR 20 OHMS, /2W P/N EOLR 20 OHMS, /2W P/N E O L R CONNECT ONLY TO UL EDP OR ETI LISTED EQUIPMENT FOREIGN SYSTEM RS-485 INTERFACE TRANSMIT TRANSMIT ENABLE RECEIVE TB TB P P2 NIM-W P4 TB P8 TB7 P0 TB4 TO MMB, SMB OR PSR- 24V Figure 4 Connecting the NIM-W to the FSI 6

7 VESDA Interface The VESDA Air Sampling interface connects to the /2, TB or TB4, terminals 2-6, depending on where the NIM-W is installed (Refer to Figure 6). Up to Air Sampling detectors can be connected to a single NIM-W. The VESDA/MXL-IQ Intelligent Interface requires a model CPY-HLI which consists of an MXL-IQ/VESDA High Level Interface and a VESDAnet Socket. The CPY-HLI can support up to VESDA detectors utilizing a VESDA network. Refer to the CPY-HLI Installation Instructions, P/N , for mounting and installation of the CPY-HLI to the VESDA detectors. Complete wiring of the Intelligent Interface as shown in Figure 6. Place the end-of-line resistors in the locations specified in Figure 6. Install the 5 leads of the Model CPY-HLICABLE interface cable (P/N ) to the /2 according to the CPY-HLI Installation Instructions, P/N (Refer to Figure 6.) To connect the CPY-HLI to the VESDA network, refer to the CPY-HLI Installation Instructions, P/N NOTE: VESDA is supported in NIM-W firmware version 2.0 and higher, SMB ROM version 6.0 and higher and CSG-M version.0 and higher. ELECTRICAL RATINGS 5 VDC, 60mA For battery calculations, the NIM-W draws 70mA from 24 VDC. NOTES:. 8 AWG minimum ohms maximum per pair.. Use twisted pair or shielded twisted pair. 4. Terminate the shield at the NIM-W enclosure only. 5. Power limited to NFPA 70 per NEC Maximum voltage 8V peak to peak. 7. Maximum current 50mA. 8. Refer to Wiring Specification for MXL, MXL-IQ and MXLV Systems, P/N revision 6 or higher, for additional wiring information. SUPERVISED CABLE P/N TO MMB, SMB OR PSR- TO POWER SUPPLY, TB2 LOAD - TO ACC, TB2, TERMINAL 9 20 OHMS, /2 W, P/N TO POWER SUPPLY, TB2 LOAD - TO ACC, TB2, TERMINAL 9 20 OHMS, /2 W, P/N OHMS, /2 W, P/N TO POWER SUPPLY, TB2 LOAD + TO ACC, TB2, TERMINAL 0 TO POWER SUPPLY, TB2 LOAD + TO ACC, TB2, TERMINAL 0 P8 TB7 P0 TB NIM-W JUMPER SETTINGS LK -2 JUMPERED LK2 2- JUMPERED 2 LK 2- JUMPERED LK AIC-4Z 2 LK2 CON4 CON CON2 2 LK TB TB SINGLE ZONE CON JUMPER SETTINGS LK -2 JUMPERED LK2 2- JUMPERED 2 LK LK 2- JUMPERED AIC-4Z 2 LK2 CON4 CON CON2 CON 2 LK MULTI ZONE TO MMB, SMB OR PSR- 24V REFER TO THE ANALASER AIR SAMPING SMOKE DETECTION MANUAL, P/N , FOR CONNECTION OF THE ACC, THE POWER SUPPLY, AND THE ANALASER DETECTOR AND AIR SAMPLING NETWORK. TO ACC #, P4 CABLE P/N TO ACC #28, P4 TO ACC #29, P4 TO ACC #0, P4 TO ACC #, P4 Figure 5 Connecting the NIM-W to the AnaLASER CABLE P/N IC-2 7

8 BLACK BROWN GREEN RED WHITE MODEL CPY-HLICABLE P/N SUPERVISED CPY-HLI PCB RS-22 PORT TO SMB 24V + _ CABLE P/N TO SMB 20 OHMS, /2 W, P/N OHMS, /2 W, P/N V net B V net A VESDAnet Socket P5 TB TB NIM-W MODEL CPY-HLICABLE (P/N ) Requirements:. 8 AWG minimum. 2. Maximum distance between MXL-IQ and CPY-HLI enclosures is 6 feet.. Cable must be in rigid conduit and can not leave the room. 4. Shielded cable is not recommended. 5. Power limited to NFPA 70 per NEC Article 760. REFER TO THE CPY-HLI INSTALLATION INSTRUCTIONS, P/N , FOR MOUNTING AND INSTALLATION OF THE MODEL CPY-HLI TO THE VESDA DETECTORS. REFER TO WIRING SPECIFICATION FOR MXL, MXL-IQ AND MXLV SYSTEMS, P/N REVISION 6 OR HIGHER, FOR ADDITIONAL WIRING INFORMATION. Figure 6 Connecting the NIM-W to the CPY-HLI Siemens Building Technologies, Inc. 8 Fernwood Road Florham Park, New Jersey 0792 Siemens Building Technologies, Ltd. 2 Kenview Boulevard Branpton, Ontario L6T 5E4 CN P/N

Installation Instructions Model MDACT MXL/FireFinder-XLS Multi-Point Digital Alarm Communicator

Installation Instructions Model MDACT MXL/FireFinder-XLS Multi-Point Digital Alarm Communicator Installation Instructions Model MDACT MXL/FireFinder-XLS Multi-Point Digital Alarm Communicator INTRODUCTION The Model MDACT from Siemens Industry, Inc. is a multipoint serial dialer for use in MXL and

More information

Fire Safety. Installation Instructions Model PSR-1 Remote Power Supply INTRODUCTION. Figure 1 PSR-1 Remote Power Supply

Fire Safety. Installation Instructions Model PSR-1 Remote Power Supply INTRODUCTION. Figure 1 PSR-1 Remote Power Supply Fire Safety Installation Instructions Model PSR- Remote Power Supply Figure PSR- Remote Power Supply INTRODUCTION The SIEMENS Model PSR- (See Figure ) is a microprocessor controlled remote power supply

More information

Fire Safety. Installation Instructions Model CSM-4 Controllable Signal Module OPERATION INSTALLATION

Fire Safety. Installation Instructions Model CSM-4 Controllable Signal Module OPERATION INSTALLATION Fire Safety Installation Instructions Model SM- ontrollable Signal Module OPERATIO The Model SM- ontrollable Signal Module has two fully supervised, programmable circuits. The outputs supply two lass B

More information

Fire Safety. Installation Instructions. Model RCC-2/R and RSE-1 Remote Control Centers OPERATION INTRODUCTION INSTALLATION

Fire Safety. Installation Instructions. Model RCC-2/R and RSE-1 Remote Control Centers OPERATION INTRODUCTION INSTALLATION Fire Safety Installation Instructions Model RCC-/R and RSE- Remote Control Centers INTRODUCTI The SIEMENS Model RCC-/R Remote Command Center (See Figure ) provides the option to remotely annunciate and

More information

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION Fire Safety Installation Instructions Model SMB- Main Control Board OPERATION The SIEMENS Model SMB- board in each MXL-IQ System controls operations and monitors input device identity, network communication,

More information

Installation Instructions Model DLC

Installation Instructions Model DLC Installation Instructions Model DLC Device Loop Card INTRODUCTION OPERATION The SIEMENS Model DLC Device Loop Card is the interface for connection of FireFinder-XLS smoke detectors, manual stations, monitor

More information

Installation Instructions Model SSD-C-REM

Installation Instructions Model SSD-C-REM Installation Instructions Model SSD-C-REM Remote System Status Display with Control ON ALARM SUPERVISORY SECURITY TROUBLE AUDIBLES SILENCED INTRODUCTION The SIEMENS Model SSD-C-REM is an optional FireFinder

More information

Fire Safety. Installation Instructions Model MMB-2 Main Control Board OPERATION. INSTALLATION Always remove power before installation.

Fire Safety. Installation Instructions Model MMB-2 Main Control Board OPERATION. INSTALLATION Always remove power before installation. Fire Safety nstallation nstructions Model MMB- Main ontrol Board OPERATON The SEMENS Model MMB- board in each MXL System controls operations and monitors input device identity, network communication, and

More information

Installation Instructions Model HZM

Installation Instructions Model HZM Installation Instructions Model Remote Conventional Zone Module INTRODUCTION The Model from is an intelligent device that connects a single zone of conventional devices to a DLC (FireFinder-XLS System)

More information

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS MXL-IQ Advanced Life Safety System ENGINEER AND ARCHITECT SPECIFICATIONS FirePrint Application Specific Fire Detection Capacity for up to 240 Intelligent Analog Detectors Expandable Up to a Stand Alone

More information

Operating Instructions MXL Multi-Line Keyboard/Display Panel

Operating Instructions MXL Multi-Line Keyboard/Display Panel Operating Instructions MXL Multi-Line Keyboard/Display Panel Local Mode Operation TRODUCTION When the MXL Keyboard/Display Panel is installed in a control panel, the components are behind a locked door.

More information

Fire Safety. Installation Instructions. Model ADBX-11. Audible Base INTRODUCTION. Model ADBX-11

Fire Safety. Installation Instructions. Model ADBX-11. Audible Base INTRODUCTION. Model ADBX-11 Fire Safety Installation Instructions Model ADBX11 Audible Base INTRODUCTION Model ADBX11 The SIEMENS Model ADBX11 Audible Base consists of a standard Series 11 base combined with an audible device. All

More information

Advanced Protection System

Advanced Protection System MXL-IQ Advanced Protection System FirePrint Application Specific Detection Capacity for up to 240 Intelligent Analog Detectors Expandable Up to a Stand Alone System Capacity of 998 Input and Output Points

More information

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual Fire Safety Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual Siemens Building Technologies, Inc. Siemens Building Technologies, Ltd. 8 Fernwood Road 2 Kenview

More information

Installation Instructions Model CDC-4

Installation Instructions Model CDC-4 Installation Instructions CDC-4 Conventional Card INTRODUCTION The SIEMENS CDC is a card that allows conventional detectors to be used on the FireFinder-XLS system. It provides four Class or Class B conventional

More information

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906 s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones

More information

ANNUNCIATOR FIXED MODULE

ANNUNCIATOR FIXED MODULE 12 Clintonville Road Northford, CT 06472 Phone: 203-484-7161 Fax: 203-484-7118 THE ANNUNCIATOR FIXED MODULE Installation Manual for the AFM-16ATF and AFM-32AF Annunciator Modules Document # 15970 3/27/95

More information

FieldServer Driver - Serial FS SBT-FSI (Siemens Building Technologies Foreign Systems Interface)

FieldServer Driver - Serial FS SBT-FSI (Siemens Building Technologies Foreign Systems Interface) Driver Version: 1.06 Document Revision: 4 Description FieldServer Driver - Serial FS-8700-40 SBT-FSI (Siemens Building Technologies Foreign Systems Interface) This FieldServer driver can be used to poll

More information

MXL-IQ CONTROL PANEL. Operation, Installation, and Maintenance Manual. Siemens Industry, Inc. Building Technologies Division Florham Park, NJ

MXL-IQ CONTROL PANEL. Operation, Installation, and Maintenance Manual. Siemens Industry, Inc. Building Technologies Division Florham Park, NJ MXL-IQ CONTROL PANEL Operation, Installation, and Maintenance Manual Siemens Industry, Inc. Building Technologies Division Florham Park, NJ P/N 315-093624-13 Siemens Building Technologies, Ltd. Fire Safety

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information

TYPE C: RETURN AIR UNDER POSITIVE PRESSURE FROM SEPARATE BLOWER

TYPE C: RETURN AIR UNDER POSITIVE PRESSURE FROM SEPARATE BLOWER Installation Instructions Model AD-HR Air Duct Monitoring Housing INTRODUCTION The SIEMENS Model AD-HR is a sampling tube, air duct monitoring housing. When used with a compatible smoke detector, smoke

More information

Multiplex Eight Input Remote Modules

Multiplex Eight Input Remote Modules Multiplex Eight Input Remote Modules 1.0 Introduction These instructions cover the installation of the D7042/D7042B Eight Input Remote Modules in a fire system supervised by an FPD-7024 Fire Alarm Control

More information

Fire Safety. Installation Instructions Model D2300CPS Fiber Optic Interface INTRODUCTION MOUNTING ELECTRICAL CONNECTIONS. Figure 1 D2300CPS Module

Fire Safety. Installation Instructions Model D2300CPS Fiber Optic Interface INTRODUCTION MOUNTING ELECTRICAL CONNECTIONS. Figure 1 D2300CPS Module Fire Safety Installation Instructions Model Fiber Optic Interface INTRODUCTION The Model from Siemens uilding Technologies, Inc. (See Figure 1) is a Fiber Optic interface for the MXL s RS-485 network (MNET

More information

Addressable NAC Output Module D327A

Addressable NAC Output Module D327A Installation Instructions Notice Addressable NAC Output Module D327A These instructions cover the installation of the D327A Addressable NAC Output Module in an analog system controlled by a Bosch D8024,

More information

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

LDM Series Lamp Driver Modules For Graphic Annunciation and Control 12 Clintonville Road Northford, CT 06472 (203) 484-7161 FAX: (203) 484-7118 LDM Series Lamp Driver Modules For Graphic Annunciation and Control Used with the System 500, System 5000, AM2020/AFP1010 and

More information

General Routing Interface

General Routing Interface General Routing Interface Features The General Routing Interface Card is an optional module to provide Fire and Fault Routing Outputs compliant with BSEN54-2: 1998 Clauses 7.9 and 8.9 and BS5839-1: 2002.

More information

MXL/MXLV 19 Rack Mount Equipment

MXL/MXLV 19 Rack Mount Equipment MXL/MXLV 19 Rack Mount Equipment Models: MXL-RK1, ACM-RK, MKB-RK, MMB-RK, MOM-RK, MPS-RK, TSP-RK, VSM-RK, CABLES-RK, MKB-3 ENGINEER AND ARCHITECT SPECIFICATIONS Standard 19 Rack Mounting for MXL and MXLV

More information

ANC BBX-FXMNS or BBX Audio Network Controller Board Installation Instructions TNC-5000 ANC Module Mounting Locations

ANC BBX-FXMNS or BBX Audio Network Controller Board Installation Instructions TNC-5000 ANC Module Mounting Locations Audio Network Controller Board Installation Instructions Module Mounting Locations The Audio Network Controller board can be mounted in two places. One position is over the Audio Network Controller module

More information

Booster Power Supply Manual

Booster Power Supply Manual Supply Manual DEVELOPED BY COPYRIGHT NOTICE General Signal Building Systems Corporation 6411 Parkland Drive Sarasota, FL 34243 (941) 739-4300 Copyright 1999 General Signal Building Systems Corporation

More information

Installation Instructions Model ABHW-4S

Installation Instructions Model ABHW-4S Installation Instructions Model ABHW-4S Intelligent Audible Base for Sleeping Area with 520Hz Low Frequency Sounder Introduction Application note The Model ABHW-4S audible base from Siemens Industry, Inc.

More information

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS CSM-4 Controllable Signal/Releasing Module ENGINEER AND ARCHITECT SPECIFICATIONS Supervised Alarm Notification Appliance Circuits Operates Audible or Visual Devices Class A (Style Z) or Class B (StyleY)

More information

IDP-Zone-6 Six Zone Interface Module

IDP-Zone-6 Six Zone Interface Module INSTALLATION AND MAINTENANCE INSTRUCTIONS IDP-Zone-6 Six Zone Interface Module BEFORE INSTALLING If the modules will be installed in an existing operational system, inform the operator and local authority

More information

SC-6 Six Supervised Control Module

SC-6 Six Supervised Control Module INSTALLATION AND MAINTENANCE INSTRUCTIONS SC-6 Six Supervised Control Module SPECIFICATIONS Normal Operating Voltage: Stand-By Current: Alarm Current: Temperature Range: Humidity: Dimensions: Accessories:

More information

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual Fire Safety FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual Siemens Building Technologies, Inc. Siemens Building Technologies, Ltd. 8 Fernwood Road 2 Kenview

More information

Public Safety DAS Annunciator Panel

Public Safety DAS Annunciator Panel Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This

More information

MMF Six Zone Interface Module

MMF Six Zone Interface Module Installation and Maintenance Instructions I56-900-005 MMF-0-6 Six Zone Interface Module SPECIFICATIONS Normal Operating Voltage: 5- VDC Stand-By Current: ma Alarm Current: 40 ma (assumes all six LEDs solid

More information

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM Description Mircom s FleX-Net TM Series Network Fire Alarm Control Panels offer modular components to meet a wide variety of applications. Designed for peerto-peer

More information

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2003-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2003-12NDS Network Fire Alarm Control Unit offers modular components to meet a

More information

NETWORK FIRE ALARM CONTROL PANEL. Features

NETWORK FIRE ALARM CONTROL PANEL. Features NETWORK FIRE ALARM CONTROL PANEL FX-2009-12N Description FX-2009-12N in a BB-5008 enclosure. Mircom s FleX-Net TM FX-2009-12N Network Fire Alarm Control Panel offers modular components to meet a wide variety

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

FireFinder XLSV Digital Emergency Voice Alarm / Communication System

FireFinder XLSV Digital Emergency Voice Alarm / Communication System s Data Sheet Fire Safety Products FireFinder XLSV Digital Emergency Voice Alarm / Communication System ARCHITECT AND ENGINEER SPECIFICATIONS Eight (8) digital audio channels Compatible with Model PMI-3

More information

The ACM-8R Annunciator Control Module

The ACM-8R Annunciator Control Module 12 Clintonville Road Northford, CT 06472 203-484-7161 FAX: 203-484-7118 The Annunciator Control Module For the System 500, System 5000, AFP-200, AM2020, AFP1010 and SFP-1024 Fire Alarm Control Panels Document

More information

OPERATION / INSTALLATION

OPERATION / INSTALLATION OPERATION / INSTALLATION & PROGRAMMING MANUAL AFP-2800 LCD-80 Fire Alarm Panel Revision 1.01 November 16, 2004 NSW (Head Office) 7 Columbia Court Norwest Business Park Baulkham Hills NSW 2153 Ph: (02)

More information

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system s Data Sheet Fire Safety & Security Products Cerberus TM PRO Fire Safety System A comprehensive fire-protection system Standard 50-point, 252-point and 504-point-capacity systems Remote viewing for the

More information

RMS/RPX Reader. User Manual

RMS/RPX Reader. User Manual RMS/RPX Reader User Manual Copyright Disclaimer Trademarks and patents Intended use FCC compliance Copyright 2005, GE Security Inc. All rights reserved. This document may not be copied or otherwise reproduced,

More information

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117 Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel Revision E 61117 CAUTION: (Read This First) This panel has been designed to make it nearly bullet proof to mistakes made when wiring

More information

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1 SmartTerminal AS7240 Installation and Operation Guide MAN2990-1 Table of Contents Page No. 1 Introduction... 3 2 Mechanical... 4 2.1 Mounting the Enclosure... 4 2.1.1 Enclosure Details... 4 2.1.2 Fixing

More information

VESDAnet Interface Card Product Guide. Document Number: 10672_05 Part Number: 30071

VESDAnet Interface Card Product Guide. Document Number: 10672_05 Part Number: 30071 VESDAnet Interface Card Product Guide Document Number: 10672_05 Part Number: 30071 Xtralis VESDA VESDAnet Interface Card Product Guide Intellectual Property and Copyright This document includes registered

More information

Innovative protection that combines power and flexibility

Innovative protection that combines power and flexibility Innovative protection that combines power and flexibility Desigo Fire Safety Modular outpaces industry standards and includes cutting-edge detection and communication capabilities usa.siemens.com/desigo-fs-modular

More information

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual Replace the following pages of Document Number 50734 (I56-993-01/D770-19-00), Revision B with the corresponding revised

More information

INTELLIGENT FIRE ALARM CONTROL PANEL

INTELLIGENT FIRE ALARM CONTROL PANEL INTELLIGENT FIRE ALARM CONTROL PANEL FX-2000 SERIES Description Mircom s FX-2000 Series Intelligent Analog Fire Alarm Control Panel is designed to provide maximum flexibility of analog system requirements

More information

FX Intelligent Analog Fire Alarm Control Panel. Installation and Operation Manual

FX Intelligent Analog Fire Alarm Control Panel. Installation and Operation Manual Advanced Life Safety Solutions Advanced Life Safety Solutions FX-2000 Intelligent Analog Fire Alarm Control Panel Canada 25 Interchange Way Vaughan, ON L4K 5W3 Tel: 905-660-4655 Fax: 905-660-4113 U.S.A.

More information

MPC-6000 / MPC-7000 / RND-2

MPC-6000 / MPC-7000 / RND-2 MPC-6000 / MPC-7000 / RND-2 Fire Alarm System Control Unit Installation, Operation and Maintenance Manual Siemens Building Technologies, Inc. 8 Fernwood Road Florham Park, NJ 07932 Tel: (973) 593-2600

More information

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor s Data Sheet Fire Safety & Security Products 08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor AS-MC-CW AS-MC-R AH-W AH-R Product Overview

More information

Desigo TM Fire Safety System A comprehensive fire-protection system

Desigo TM Fire Safety System A comprehensive fire-protection system s Desigo TM Fire Safety System A comprehensive fire-protection system Standard 50-point, 252-point and 504-point-capacity systems Remote viewing for the 252- point and 504-point systems One (1) or (2)

More information

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2003-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron's MMX-2003-12NDS is a powerful intelligent networkable fire alarm solution designed

More information

FMR Installation Instructions. Addressable Fire System Controller

FMR Installation Instructions. Addressable Fire System Controller FMR-7033 EN Installation Instructions Addressable Fire System Controller EN 2 FMR-7033 Installation Instructions Contents Contents Contents...2 1.0 Introduction...3 2.0 Description...3 3.0 Device Mounting...3

More information

VESDA. Accessories Guide. May 2011 Document: 10258_06 Part Number: 30012

VESDA. Accessories Guide. May 2011 Document: 10258_06 Part Number: 30012 VESDA Accessories Guide May 2011 Document: 10258_06 Part Number: 30012 Intellectual Property and Copyright This document includes registered and unregistered trademarks. All trademarks displayed are the

More information

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum. September 29, 1997 Firecycle III 433 a 1. PRODUCT NAME VIKING Model E-1 Manufactured 1997 Present 2. MANUFACTURED FOR THE VIKING CORPORATION 210 N Industrial Park Road Hastings, Michigan 49058, U.S.A.

More information

SPEC SHEET. Simple Expansion Solutions ZONE EXPANSION MODULES: SINGLE AND MULTIPLE POINT

SPEC SHEET. Simple Expansion Solutions ZONE EXPANSION MODULES: SINGLE AND MULTIPLE POINT SPEC SHEET Simple Expansion Solutions Expand your DMP panel options with a wide array of expansion modules. Add supervised Class B burglary zones. Connect non-powered burglary or fire type devices for

More information

Rev. B. TrueAlert Addressable Controller Application Manual

Rev. B. TrueAlert Addressable Controller Application Manual 574-996 Rev. B TrueAlert Addressable Controller Application Manual This page intentionally blank Copyrights and Trademarks Copyright 000 Simplex Time Recorder Company, Westminster, MA 044-000. All rights

More information

ACCURATE ELECTRONICS INC

ACCURATE ELECTRONICS INC ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A

More information

Cerberus PRO A comprehensive fire-protection system

Cerberus PRO A comprehensive fire-protection system Cerberus PRO A comprehensive fire-protection system Cerberus TM ARCHITECT AND ENGINEER SPECIFICATIONS Standard 252-point and 504-point fire systems Remote viewing for the 252- point and 504-point systems

More information

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description MODUL-R FIRE ALARM CONTROL PANELS MR-2900/MR-2920 Addressable Fire Alarm Control Panels Description MR-2900 Fire Alarm Control Panel The MR-2900 fire alarm system control unit is the heart of a sophisticated

More information

Air Duct Housings. Description

Air Duct Housings. Description Air Duct Housings Series IL, and Series 3 Ionization or Photoelectric Detectors Optional Relays for Supplementary Equipment Operation Optional Control Module for Self-contained Operation (Series 3 Detectors

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D2 MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D2 GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air Document No. 155-755 Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air Description Features Application The Q-Series Relative Humidity and

More information

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels R 12 Clintonville Road, Northford, CT 06472 Phone: (203) 484-7161 FAX: (203) 484-7118 Instruction Manual for the MS-4012/4024 and CMS-4012/4024 Fire Alarm Control Panels Document 15586 5/11/93 Revision:

More information

E-PDD Duct Smoke Detector Installation Sheet

E-PDD Duct Smoke Detector Installation Sheet E-PDD Duct Smoke Installation Sheet E-PDD operation The duct smoke detector's primary purpose is to provide early warning of an impending fire and shut down the HVAC unit in order to prevent smoke from

More information

4100U City and Relay Cards Installation Instructions

4100U City and Relay Cards Installation Instructions 4100U City and Relay Cards Installation Instructions Introduction This publication describes the installation procedure for the following: 4100-6031/6032 City Circuit Cards 4100-6033 Alarm Relay Card Inspecting

More information

AU MX Digital Loop Card Installation Instructions

AU MX Digital Loop Card Installation Instructions 4100-6077AU MX Digital Loop Card Installation Instructions Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS - Follow the instructions in this installation manual. These instructions must be followed

More information

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE K3179V2 2/11 Rev. A ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE FEATURES The ADEMCO 4208SNF Universal Class A Module can be used in either of two different applications.

More information

Desigo TM Fire Safety System A comprehensive fire-protection system

Desigo TM Fire Safety System A comprehensive fire-protection system s Desigo TM Fire Safety System A comprehensive fire-protection system Standard 252-point and 504-point capacity systems Remote viewing for the 252- point and 504-point systems One (1) or (2) two-heightunit

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

Conventional Releasing Control Panel

Conventional Releasing Control Panel s Data Sheet Fire Safety Products Conventional Releasing Control Panel Pre-Action Deluge Agent-Releasing Fire System Model TXR-320 Remote configurable Up to two (2) hazard areas Operable with the following:

More information

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES POWER SUPPLY AND BATTERY CHARGER AC AND DC STATUS INDICATORS ENOUGH POWER TO SUPPORT UP TO 3 MAGLOCKS OR ELECTRIC STRIKES PLUS REQUIRED

More information

Marine Fire Detection System Manual MXL Control Panel

Marine Fire Detection System Manual MXL Control Panel Marine Fire Detection System Manual MXL Control Panel US Coast Guard Approved Certificate No. (Cert No:6.002/22/7) Reference ULI File No. S522 Siemens Building Technologies, Inc. Fire Safety 8 Fernwood

More information

Control Relay Modules

Control Relay Modules TM INTERNATIONAL ANALOG ADDRESSABLE INPUT/OUTPUT DEVICES Control Relay Modules Model SIGA-CR, SIGA-MCR, SIGA-CRR, Features! Provides one no/nc contact (SIGA-CR/MCR) Form C dry relay contact can be used

More information

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep. 140 58th St. Brooklyn, NY Power Supply/Chargers Installation Guide Models Include: eflow4n/eflow4nx - 4 amp @ 12VDC or 24VDC eflow4n8/eflow4nx8 eflow4n8d/eflow4nx8d - 4 amp @ 12VDC or 24VDC - 4 amp @ 12VDC

More information

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3 OPERATORS MANUAL AFP-300/400 INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3 NSW (Head Office) 7 Columbia Court Norwest Business Park Baulkham Hills NSW 2153 Ph: (02) 9899-4155

More information

FireNET Plus Wiring Instructions

FireNET Plus Wiring Instructions FireNET Plus Wiring Instructions This manual provides wiring instructions for the 1 loop and 2 loop version of the FireNET Plus panels, which supports our finest Hochiki s DCP protocol. Note: Refer to

More information

RM-1 Series. Remote Microphones. (RM-1, RM-1SA) Document Revision B RM-1 RM-1SA. RM-1 on ADP-4 dress panel. RM-1SA in a CAB-RM or CAB-RMR

RM-1 Series. Remote Microphones. (RM-1, RM-1SA) Document Revision B RM-1 RM-1SA. RM-1 on ADP-4 dress panel. RM-1SA in a CAB-RM or CAB-RMR This product has been certified to comply with the requirements in the Standard for Control Units and Accessories for Fire Alarm Systems, UL 864 9th Edition. The following products have not received UL

More information

MODEL B2 INSTALLATION MANUAL

MODEL B2 INSTALLATION MANUAL RELEASE DEVICES GENERAL DESCRIPTION MODEL B2 INSTALLATION MANUAL S/N: The B2 Series Time Delay Release Devices are UL Listed, Canadian Listed, and CSFM Listed for use on rolling doors, single-slide and

More information

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features Fire Control Panels UL, ULC, CSFM Listed; FM Approved* Features Compatible with Simplex 4120 Network Converts multiple 4120 network communications signals into a single fiber optic link to: Multiplex audio

More information

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note Product Overview: The Pertronic F4 Remote LED Mimic / Aux Relay Module F4-RMAX is an optional extra for the Pertronic F4 conventional 4-zone fire alarm panel. This board enables the fire alarm panel to

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS The SensorNet I/O Module provides attachment for up to 32 alarms and up to 16 switched devices. An RS-232 or RS-422 communications port is also provided for receiving serial alarms.

More information

SIGA-CC1 Single Input Signal Module Installation Sheet

SIGA-CC1 Single Input Signal Module Installation Sheet SIGA-CC1 Single Input Signal Module Installation Sheet Personality codes Use the personality codes described below to configure the SIGA-CC1 module. See Table 1 for listing information Table 1: Personality

More information

LifeAlarm Fire Alarm Control Panels

LifeAlarm Fire Alarm Control Panels LifeAlarm Fire Alarm Control Panels UL, ULC Approved* Features Control panel operator convenience features: Wide viewing angle 2 x 20 (40 character) alphanumeric LCD and dedicated LEDs provide convenient

More information

PSN-1000 & PSN 1000(E) Installation Manual

PSN-1000 & PSN 1000(E) Installation Manual PSN-1000 & PSN 1000(E) Installation Manual Potter Electric Signal Company, LLC St. Louis, MO Customer Service: (866) 240-1870 Technical Support: (866) 956-1211 Fax: (314) 595-6999 www.pottersignal.com

More information

FireSeeker Fire Alarm Control Panel Model FS-250 Installation, Operation and Maintenance Manual

FireSeeker Fire Alarm Control Panel Model FS-250 Installation, Operation and Maintenance Manual FireSeeker Fire Alarm Control Panel Model FS-250 Installation, Operation and Maintenance Manual P/N 315-049353-1 Siemens Building Technologies Fire Safety TABLE OF CONTENTS INTRODUCTION... 1 CONTROL PANEL

More information

asimplex 4020 Fire Alarm System Contractor Installation Instructions Technical Manuals Online! -

asimplex 4020 Fire Alarm System Contractor Installation Instructions Technical Manuals Online! - asimplex 4020 Fire Alarm System Contractor Installation Instructions 0 1995 Simplex Time Recorder Co FA4-21-400 (574-061) All specifications and other information shown were current as of publication and

More information

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description FIREFLEX VACTEC description This FIREFLEX VACTEC integrated fire protection system consists of a vacuum system trim totally pre-assembled, prewired and factory tested. All electrical and mechanical components

More information

Remote NAC Power Supply D7038

Remote NAC Power Supply D7038 Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus

More information

SENTROL ZX440F. Security System Control. Installation/ Programming

SENTROL ZX440F. Security System Control. Installation/ Programming SENTROL ZX440F Security System Control Installation/ Programming 1 TABLE OF CONTENTS Table of Contents New Features... 6 ZX440F Wiring Diagram... 7 ZX440F Terminal Descriptions... 8 ZXCFM Connection Descriptions...

More information

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel 12 Clintonville Road Northford, CT. 06472 (203) 484-7161 FAX:(203) 484-7118 The TC-4F Time Control Module For the Sensican 2000 Fire Alarm Control Panel Document # 15972 3/27/95 Revision C P/N 15972:C

More information

HRX3000. Technical Manual

HRX3000. Technical Manual HRX3000 Technical Manual Contents: Specification...2 Connectors...3 Power (J21)...3 RS-485 Network Connectors (J6 and J7)...4 RS-232 to PC (J8)...5 Printer and Fire Alarm Panel (J19)...6 TCP/IP...8 Modem

More information

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER Cautions and Warnings DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED. Upon unpacking your Simplex product, inspect the contents of the carton for shipping damage. If damage is apparent, immediately

More information

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL MADE IN THE U.S.A. U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION SERIAL NUMBER The Cookson Company FIREFLY II PLUS Time Delay Release

More information

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

THE SS90 SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL S S S S S S S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED U 99Y9 RESET L RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

Fratech Multipath-IP

Fratech Multipath-IP Rev 2.0 (May 2013) Installer Manual 1 Current Part Numbers: Fratech Multipath-IP E-Link STU PCB & Accessory Kit only In Metal Enclosure with Power Supply 998325-PK 998325-XS Installer Manual This document

More information