Intelligent Swing Gate Turnstile Operating Manual CPW-322CS

Size: px
Start display at page:

Download "Intelligent Swing Gate Turnstile Operating Manual CPW-322CS"

Transcription

1 Intelligent Swing Gate Turnstile Operating Manual CPW-322CS

2 C O N T E N T S 1. General Descriptions Definitions Swing Gate Turnstile Passing Modes Safety Precautions Product Structure Mechanical system Electric System The working principle of turnstile system Product installation, inspection and tests Product installation Product status inspection Product function tests Power on self test function test Normal passing test IN & OUT direction passing modes test Alarm Function test Anti-clamping function test Emergency escape function test Product usage Turnstile single directional passing... 12

3 7.2 Turnstile single directional continuous passing Turnstile bi-directional passing Product cleaning and maintenance Daily cleaning Product regular maintenance Product common troubles and trouble shootings Indicator lights failure System power failure...18 Appendix...21 Contact Us...27

4 1.General Descriptions Intelligent swing gate turnstile CPW-322CS is one of the most slimmest turnstile gates in the industry; the design is with bridge structure, transparent and bright, simple and elegant; the housing made of great stainless steel is durable; the mechanism module is imported from international top brand DC brushless motor and precise positioning encoder, so as to ensure turnstile gate can move quickly and accurately, stably and quietly, with low-power consumption, energy conservation and environment protection. CPW-322CS is equipped with the dry contact signal input interface, RS485/RS232 interface, TCP/IP interface (optional), compatible with all kinds of access controllers. It is suitable for commercial buildings, subways, airports, customs, exhibition halls, government buildings, financial institutions, clubs and other high-end indoor applications. The product has been strictly tested before leaving the factory. But to ensure the safe and reliable operating of the product, users are recommended to read the manual carefully before operating so as to avoid improper operation and damage to the interests of users. 2. Definitions 2.1 Swing Gate Turnstile The swing gate turnstile consists of housing and two movable flaps. By moving at 90, the flaps can achieve the purpose of stopping or releasing. According to different ways of mechanism combination type, swing gate turnstile can be divided to be single mechanism swing gate turnstile and dual-mechanism swing gate turnstile. Single mechanism swing gate turnstile: only one single mechanism is equipped inside the housing (as shown in Figure 2.1-1). Dual-mechanism swing gate turnstile: dual-mechanism with independent working is equipped inside the housing (as shown in Figure 2.1-2). 1 / 27

5 2.1-1 Single mechanism swing gate turnstile Dual-mechanism swing gate turnstile According to different numbers of passageway, swing gate turnstile can be divided to be single passageway swing gate turnstile and multi-passageway speed gates turnstile. Single passageway swing gate turnstile: it consists of two single mechanism swing gate turnstiles. (as shown in Figure 2.1-3) Multi-passageway swing gate turnstile: it consists of two single mechanism swing gate turnstiles and multiple dual-mechanism swing gate turnstiles (as shown in Figure 2.1-4). Figure Single passageway swing gate turnstile Figure Multi-passageway swing gate turnstile 2.2 Passing Modes Controlled mode: It is the default standby mode of turnstile. When a valid opening signal is given, turnstiles gates open to allow users to pass through. The valid opening signals can be manually open button signal and access control board open signal. Free passing mode: If infrared sensors detect user s entering into passageway, the turnstile will open automatically and allow user go through. Forbidden passing mode: When a valid opening signal is given, the flaps are closed and users are not allowed to pass through. 2 / 27

6 3. Safety Precautions Although a series of testing have been carried out before turnstile leaves the factory and the turnstile can run safely and stably, users should perform proper installation and commissioning strictly in accordance with the operating manual before the turnstile can be put into use. Manufacturers may refuse to take any responsibility for any consequences caused by improper operation or human damage. Before installation, please pay attention to the following safety precautions: Only certified and trained electrical technicians may perform the strong electric 220VAC electrical connections. It is prohibited to install the turnstile without proper mounting foundation. Disconnect the power supply of all external systems (such as access control, visitor management system, ticketing system, etc.) during maintenance work. A main leakage switch or residual current operated devices are compulsory. The electrical wiring operation of turnstile must comply with the attached wiring diagrams. Before the turnstile can be put into use, make sure its functions are tested OK. During maintenance work, the fixing bolt must be checked and tighten. Current carrying components like switching power supply, motor reducer, resistor, lamps, etc. shall not be touched while in operating as the high temperature might cause skin burns. It is forbidden to apply heavy force on the turnstile; otherwise, unnecessary damage may be caused. It is recommended to separate the turnstile with other equipment s power supply interface; otherwise the turnstile might be damaged due to the mutual interference between the equipment. The turnstile is not equipped with explosion-proof design, and it is not allowed to apply the turnstile to an environment with danger of inflammable or explosion. However, it is optional for user to purchase other types for the purpose. 3 / 27

7 4. Product Structure CPW-322CS consists of mechanical system and electric system. Its outline dimensions are shown as Figure 4 as below. 4.1 Mechanical system Figure 4 The mechanical system of turnstile consists of housing and mechanism. The housing is shown as Figure 4.1. It consists of swiping-card panel, passageway status indication, direction indication, infrared sensor and cabinet, etc. The mechanism consists of motor reducer, encoder, clutch and flaps, etc. 4 / 27

8 Figure Electric System The electric system of turnstile consists of main control board (see Appendix A1), sub-panel control board (see Appendix A2), motor control board (see Appendix A3), infrared sensor, passageway status indicator, direction indicator, buzzer and power module. The counter, sound-light alarm device and access control system are optional. 5. The working principle of turnstile system (1) Turn on turnstile system power; the system will perform power on self test; buzzer alarms for prompting. After the alarm, system goes into standby mode; turnstile gate closes; passageway status indicator turns green and direction indicator turns red. (2) User gives a valid opening signal (access control system swiping-card open signal, or turnstile system open button signal) for IN/OUT direction to main control board. (3) After main control board receives a valid opening signal for IN/OUT direction, it sends control signal to sub-panel control board, motor control board, passageway status indicator and direction indicator. The IN/OUT direction indicator will turn from red to green; and OUT/IN 5 / 27

9 passageway status indicator will turn from green to red, then turnstile gate opens to let user pass through. (4) User passes through the turnstile according to direction indicator, and infrared sensors will detect the entire process when user is passing and send user s position signal to main control board. After user finishes passing through, main control board sends control signal to sub-panel control board, motor control board, passageway status indicator and direction indicator, then turnstile gate closes and the system enters into standby mode; passageway status indicator turns green and direction indicator turns red. (5) If user doesn t provide a valid opening signal and then go into the passageway, the system will lock flaps to forbid passing; at the same time, buzzer will alarm until user leaves the passageway. 6. Product installation, inspection and tests 6.1 Product installation (1) Prepare necessary tools for installing turnstile and choose the auxiliary parts according to packing list. (2) Confirm the system constitution and operating mode. Get ready to install after finishing system planning. (3) Drill holes after confirming the positions. Pre-bury (N+1)*8 M10 expansion bolts as shown in Figure 6.1. Note: N means the lane quantity. 6 / 27

10 Figure 6.1 (4) Put both strong power and weak power cables into 3/4 PVC tube, and bury them to the suitable positions. (5) Move housing cabinets respectively to the installing positions, making them align with the anchor bolts. (6) Check the system structure and operating mode. (7) Open one housing cabinet and choose one turnstile as a reference (It is recommended to choose the middle unit as a reference). Respectively align the drill holes of bolts on the chassis with anchor bolts and then tighten the nuts tentatively. (8) Open the adjacent turnstile housing. Respectively align the drilling holes of bolts on the chassis with anchor bolts according to the above reference and tighten the nuts tentatively. (9) Connect the power wires, control wires as well as the ground wires properly according to the wiring diagram. 7 / 27

11 (10) After checking the turnstile status and performing function commissioning are OK, tighten the anchor bolts and nuts. Note: (1) The depth of PVC tubes buried shall be more than 60mm. The height above the ground shall be more than 50mm. And the PVC tube shall be bent return so as to avoid water falling in. (2) All the above operation should be carried out when power off. And please make sure the protection ground wire of system is connected correctly, properly and firmly. 6.2 Product status inspection It is required to check the turnstile status after it is properly installed. Detailed procedures are as below: (1) Check the proper wiring among all electric components. Details please refer to Appendix. (2) After the wiring are checked OK, connect the turnstile to power. (3) After the turnstile finishes power on self checking, both flaps should move left and right and buzzer will alarm for prompting. After the alarm stops, turnstile gate should be closed. Please refer to the detailed status of passageway status indicator and direction indicator in Table 6.2. Table 6.2 Swing gate turnstile Passing Mode Working Status Table Passing Mode Turnstile Opening Status The direction indicator (subject to the right hand) The passageway status indicator (subject to the right hand) IN & OUT Controlled Passing When standby, turnstile gate is closed; after turnstile receives a valid opening signal, turnstile gate opens and user can pass through normally. (1) When standby, IN & OUT direction indicator turn red. (2) When IN/OUT direction receives a valid opening signal, IN/OUT direction indicator light turns green. OUT/IN direction indicator turns red. (1)When standby, IN & OUT passageway status indicator light turns green. (2)When IN/OUT direction receives a valid opening signal, IN/OUT passageway status indicator turns green; OUT/IN passageway status indicator 8 / 27

12 turns red. (1) When standby, IN & OUT direction indicator turns red. IN / OUT Controlled Passing, OUT / IN Forbidden Passing When standby, turnstile gate is closed; after the controlled direction of turnstile receives a valid opening signal, turnstile gate opens and user can pass through normally; after the forbidden direction of turnstile receives a valid opening signal, turnstile gate doesn t open. (2) When the controlled direction receives a valid opening signal, direction indicator of the controlled direction turns green; the direction indicator of forbidden direction turns red. (3) When the forbidden direction of turnstile receives a valid When standby, the controlled direction and forbidden direction receive valid opening signals in these three cases, the passageway status indicator of controlled direction turns green; the direction indicator of forbidden direction turns red. opening signal, both direction indicators of controlled direction and forbidden direction turn red. (1) When standby, the direction indicator of free passing direction (1) When standby, IN&OUT passageway status indicator light IN / OUT turns green; the direction When standby, turnstile gate is turns green. Controlled indicator of controlled direction closed; after IN/OUT direction Passing, (2) When IN/OUT direction receives a valid opening signal, turns red. OUT / IN receives a valid opening signal, turnstile gate opens and user (2) When IN/OUT direction Free IN/OUT passageway status can pass through normally. receives a valid opening signal, Passing indicator turns green; OUT/IN IN/OUT direction indicator light turns green; OUT/IN direction passageway status indicator light turns red. indicator turns red. (4) Check whether the turnstile working mode is in accordance with user s requirements. Please refer to Table 6.2 for details. If the direction indicator or passageway status indicator is abnormal, please refer to Chapter 9 Product common troubles and trouble shootings and contact the manufacturer. (5) Check whether the infrared sensors of each passageway work normally or not. Please check one by one. When you block one pair of infrared sensors, the corresponding infrared indicator lights 9 / 27

13 on main control board should be off. If the corresponding lights are abnormal, please refer to Chapter 9 Product common troubles and trouble shootings or contact us. (6) Check the running status of each moving flaps. When standby, use the test buttons to provide opening signal. The flaps opening and closing should be synchronous, stable and complete. If the running status of flaps are abnormal, please contact us. Note: Before leaving the factory, a series of tests have been carried out on the turnstile. But to ensure the stable running of turnstile system, it is necessary to perform inspection on turnstile status after properly installed at site. The inspection should be confirmed by the professionals before carried out. The turnstile parameters should not be modified at will without the approval of the manufacturer. 6.3 Product function tests After checking the turnstile status, it is also required to test the turnstile functions. Detailed tests include: power on self test function test, normal passing test, IN & OUT passing modes test, alarm function test, anti-clamping function test and emergency escape function test Power on self test function test After electrified, turnstile gate should perform power on self test; both flaps should move left and right; the buzzer will alarm for prompting. After alarm stops, flaps should return to the closing position automatically Normal passing test Under standby status, turnstile gate is closed. Using turnstile test button to provide a valid opening signal, flaps should be open. Within the allowed passing time (usually about 5S), user can pass through normally; during user s passing, the buzzer should not alarm. After user finishes passing, flaps should be closed IN & OUT direction passing modes test Set the turnstile passing models via the WORK MODE module on main control board, shown as Figure The IN direction and OUT direction can be separately set as Controlled Passing / Free Passing / Forbidden Passing. Generally turnstile passing modes are set as IN & OUT controlled 10 / 27

14 passing (default), IN/OUT controlled passing & OUT/IN forbidden passing, as well as IN/OUT controlled passing & OUT/IN free passing. Observe whether flaps status, direction indicator and passageway status indicator are normal or not under different working modes. If they work normally, then the passing modes can switch normally. If not, the mode switching function is abnormal. Please refer to Table 6.2 for details. Figure Alarm Function test During the testing, buzzer should alarm for prompting under the following situations: turnstile performs power on self test, pedestrian illegal intrusion, reversed passing or tailgating passing, shown as Figure / 27

15 Figure Anti-clamping function test Infrared Anti-clamping Machinery Anti-clamping Machinery anti-clamping: After providing a valid open signal, if user manually stops flaps during the opening or closing process, flaps should stop moving. Infrared anti-clamping: When turnstile gate is working, if infrared sensors at anti-clamping region (the middle two pairs of infrared sensors) are covered, flaps should stop moving. After the person / obstacle leaves the anti-clamping region, flaps should continue moving Emergency escape function test Long-press the emergency escape button (red button), turnstile gate opens and users can freely pass through from both directions. 7. Product usage When using swing gate turnstile, users should obey the passing rules of Swiping cards outside the yellow line, One person one card, and No tailgating or reversed passing. Note: Swiping cards behind the yellow line, one person one card, and No tail-gating and reversed passing means user should stand outside of the yellow line to swipe the card; each time a valid card swiped only allows one person to pass through; tailgating or reversed passing is forbidden. 7.1 Turnstile single directional passing Single directional passing is shown as Figure 7.1. Under standby status, user provides a valid opening signal of IN/OUT direction to the turnstile, turnstile gate opens, and user passes through. 12 / 27

16 After user finishes passing, turnstile gate closes and returns to the home position. Figure 7.1 Turnstile single directional passing 7.2 Turnstile single directional continuous passing When users provide more than one opening signal at the same direction, turnstile system will memorize all the passing requests and finish each passing action in sequence. If users give valid opening signals when turnstile gate does not close, flaps will still be open, users can go through after giving valid open signal. 7.3 Turnstile bi-directional passing Under standby status, user A stands behind the yellow line of IN direction and provides a valid open signal of IN direction to the turnstile, turnstile gate opens, and user A passes through. After user A finishes passing, turnstile gate closes. User B stands outside the yellow line of OUT direction and provides a valid open signal of OUT direction to the turnstile, turnstile gate opens, and user B passes through. After user B finishes passing, turnstile gate closes. The turnstile and users status during the passing process of user A is shown as Figure The turnstile and users status during the passing process of user B is shown as Figure Note: For bi-directional passing, users can only swipe valid cards and pass through in sequence. It is not allowed to pass through simultaneously or reversely. The white one indicates user A, while the blue one indicates user B. Figure Passing Process of User A 13 / 27

17 Figure Passing Process of User B 8. Product cleaning and maintenance The cleaning and maintenance of turnstile will directly affect its service life. Therefore, it requires periodic cleaning and maintenance. 8.1 Daily cleaning The daily cleaning and maintenance include surface cleaning and internal cleaning. The cleaning frequency is once a week. Please refer to Table 8.1 for details. Table 8.1 Daily Surface & Internal Cleaning Area Tools Cleaning Methods Notes Housing stainless steel surface 1 Clean and soft cloth 2Stainless steel cleaner polish, watered alkalescent detergent (Proportion7:1) 1Disconnect to power, and use a clean soft cloth to clean the dust on surface. Spray the stainless steel cleaner polish on the clean cloth, and then wipe along the lines of brushed stainless steel surface until it s clean and bright again. 2Use the cloth to clean the bottom and the surrounding Please do not use water, strong alkaline solvent or acidic solvent to clean. ground; Make sure the bottom is dry, and without any water. 1Clean the ordinary floating dust: Wipe the surface of Organic glass 1Clean and soft cloth 2Clean solvent (special organic glass clean solvent, 1% of soapy water, glass cleaning liquid "glassy water", 30% concentration medical alcohol, diesel and other alkalescent or acidulous solvent) organic glass gently with a clean cloth moistened with solvent, or spray the organic glass with a sprayer, then wipe with a clean cloth gently, and finally wipe with a dry cloth. 2Clean glue dust: coat little diesel oil on cotton cloth and gently wipe. If you don t have the diesel oil, you can handle it with the method of cleaning the ordinary floating dust, watered 30% concentration medical alcohol. 3Small scratches treatment of organic glass surface: Wipe the scratches gently for about 5 minutes by cotton with little Please do not use acetone-containi ng solvents, industrial alcohol, and strong alkaline solvent or acidic solvent to clean. toothpaste. 14 / 27

18 1Clean and soft cloth 1Clean the ordinary floating dust:wipe the surface of 2Clean solvent (weak organic glass gently with a clean cloth moistened with solvent, Tempered glass alkaline and weak acid solvent, like glass cleaning liquid "glassy water", 1% concentration soapy water, 30% concentration medical or spray the organic glass with a sprayer, then wipe with a clean cloth gently, and finally wipe with a dry cloth. 2Clean stubborn stains: Wipe with a clean cloth moistened with 30% concentration medical alcohol or warm vinegar; Or use glass cleaning solvent to clean. Please do not use strong alkaline solvent or acidic solvent to clean. alcohol, vinegar, strong 3Clean surface frost: wipe with a clean cloth moistened with brine etc.) 30% of medical alcohol or brine. 1 Disconnect to power and then open the maintenance door. Use blow gun to remove the internal dust and fines. The mechanical core, boards, switching power, gaps and bottom Internal cleaning 1Clean soft cloth 2Air blow gun 3Stainless steel cleaner polish need to be cleaned specially, so as to ensure it s clean and dry. 2 Use the cloth to wipe the dust inside the cabinet and that on the mechanical parts. 3 Dip another clean cloth with suitable amount of stainless Don t use the dust catcher or air-heater steel cleaner polish to wipe along the lines of the brushed stainless steel surface of the access door until it s clean and bright again. 8.2 Product regular maintenance Please pay attention to the followings: (1)Non-professionals are not allowed to open the turnstile housing cabinet to perform tests, maintenance or product services; (2)It is forbidden to use hard objects to clean the turnstile surface, or it will be easily scratched. (3)It is forbidden to use water to clean, or it will cause the short circuit of electric components and affect the normal usage of the turnstile. (4)It is required to check the connections of each interface on the mechanism periodically, so as to avoid the looseness of the parts. (5)It is required to use lubricants to lubricate the mechanism parts periodically. 15 / 27

19 (6)It is required to check the sockets and wiring connections periodically so as to ensure the stability of the wiring connections. (7)It is required to check the grounding connection of the electric system periodically so as to avoid electric leakage. (8)After finishing the maintenance, please connect the turnstile system to power and close the maintenance doors. 9. Product common troubles and trouble shootings 9.1 Indicator lights failure When standby, the direction indicator turns red (as shown in Figure 9.1-1) and passageway status indicator turns green (as shown in Figure 9.1-1); the running light (RUN) of main control board is flashing at a frequency of one time per second, as shown in Figure 9.1-2; the infrared sensor status indicator light of control board is often on when there is nothing to cover the infrared sensor. Under IN & OUT controlled passing mode, when IN/OUT direction receives a valid open signal, IN/OUT direction indicator turns green, IN/OUT passageway status indicator turns green; OUT/IN direction indicator light turns red, OUT/IN passageway status indicator turns red. Indicator light failures: 16 / 27

20 All the lights are off. The direction indicator or passageway status indicator is abnormal. The running Light (RUN) of main control board is not flashing. All the lights are flashing. When user covers the infrared sensor, the infrared detector status indicator light on main control board is still on. (1) All the lights are off. Cause Analysis: malfunction of wiring connection, power supply or control board Troubleshooting:Check whether the wiring connection and power supply output are normal or not. If normal, then the control board might be damaged. If wiring connection is abnormal, please fix the wiring connection. If power supply is faulty, please contact the manufacturer. (2) The direction indicator or passageway status indicator is abnormal. Cause Analysis: malfunction of wiring connection, main control board, direction indicator or passageway status indicator light. Troubleshooting:Check whether the wiring connection is normal or not, if abnormal, please fix the wiring connection; if the wiring connection is normal, then check whether the direction indicator or passageway status indicator is normal; if power supply is normal, the direction indicator or passageway status indicator might be damaged; if the power supply is abnormal, main control board might be damaged, please contact the manufacturer. (3) The running Light (RUN) of main control board is not flashing. Cause Analysis: The control board malfunctions or the toggle switch of communication panel has been switched to UPDATE. Troubleshooting: Check the toggle switch on communication panel of the control board and make sure it is at WORK. And then restart the turnstile system. If the system still malfunctions, it proves the control board might be faulty. Please contact 17 / 27

21 the manufacturer. (4) All the lights are flashing. Cause Analysis: Short circuit or the control board is faulty. Troubleshooting:Check whether there exists any short circuit. If yes, please rule out and fix the wiring connection. If there s no short circuit, then it proves the control board might be faulty. Please contact the manufacturer. (5) When user covers the infrared sensor, the infrared detector status indicator light on main control board is still on. Cause Analysis: Wiring connection malfunction of the infrared detector and the control board, or the control board malfunctions. Troubleshooting:Check whether the wiring connection of infrared detector and control board are normal or not, if abnormal, please fix the wiring connection; if normal, please check whether the power supply of infrared detector is normal or not; if power supply is normal, the infrared detector might be damaged, please contact the manufacturer. If power supply of infrared detector is abnormal, the control board might be damaged, please contact the manufacturer. 9.2 System power failure When standby, the POWER light on main control board is normally ON, shown as Figure The LED 1 & LED 5 power indicator lights on motor control board are normally ON, shown as Figure / 27

22 Figure POWER light on main control board Figure LED 1 & LED 5 power indicator lights on motor control board System power failures: The V/AC power cable of turnstile system has been connected, but not electrified. The POWER light on main control board is not ON; The LED 1 & the LED 5 power indicator lights on motor control board are not ON. (1) V/AC power cable of turnstile system has been connected, but not electrified. Cause Analysis: The contact chip of power socket is loosened or damaged; the V/AC power cables are damaged. Troubleshooting:Check whether the contact chip of power socket is loosened or damaged. If yes, please repair or replace the socket. If the power socket is normal, please rule out whether the V/AC power cable is damaged. If yes, please replace the V/AC power cable. If the V/AC power cable is normal, please check whether the leakage protection switch is working normally. If not, please replace the leakage protection switch or contact the manufacturer. If the leakage protection switch is working normally, please check whether the output voltage of power supply module is normal and contact the manufacture with the feedback. (2)The main control board doesn t electrify. The POWER light on the control board is not ON. Cause Analysis: The switch power supply is damaged, the wiring connection between the switch power supply and main control board is faulty, or main control board is faulty. 19 / 27

23 Troubleshooting:Check whether the switch power supply is damaged. If yes, please contact the manufacturer. If it is normal, please check whether the wiring between the switch power supply and the main control board is normal. If not, please repair the wiring connection. If the wiring between the switch power supply and the main control board is normal, then it is possible that the main control board is faulty. Please contact the manufacturer. (3)The motor control board doesn t electrify. The LED 1 and the LED5 power indicator lights on the motor control board are not ON. Cause Analysis: The switch power supply is damaged, the wiring connection between the switch power supply and the motor control board is faulty, or the motor control board is faulty. Troubleshooting:Check whether the switch power supply is damaged. If yes, please contact the manufacturer. If it is normal, please check whether the wiring between the switch power supply and the motor control board is normal. If not, please repair the wiring connection. If the wiring between the switch power supply and the motor control board is normal, then it is possible that the motor control board is faulty. Please contact the manufacturer. Note: The above shows the common failures of the products. For troubleshooting methods of more failures, please refer to the special maintenance manual of the product. 20 / 27

24 Appendix The turnstile main control board is shown as Figure A1; the sub-panel control board is shown as Figure A2, while the motor control board is shown as Figure A3. Figure A1 Turnstile Main Control Board Figure A2 Sub-panel control board 21 / 27

25 Figure A3 Motor Control Board The electrical board installation distribution of main cabinet and deputy cabinet are shown as Figure B1. The electric wiring connection diagram of main cabinet is shown as Figure B2; The electric wiring connection diagram of deputy cabinet is shown as Figure B3; The control panel instruction of main control board is shown as Figure B4; The wiring instructions for the external interface of control panel is shown as Figure B5. Figure B1 Electrical board installation distribution of main cabinet and deputy cabinet 22 / 27

26 Figure B2 The electrical wiring connection of the main cabinet 23 / 27

27 Figure B3 The electrical wiring connection of the deputy cabinet 24 / 27

28 Figure B4 The control panel instruction of main control board 25 / 27

29 Figure B5 The wiring instructions for the external interface of control panel Note: The product design and specifications are subject to change without prior notice. 26 / 27

30 Contact Us CMOLO INTERNATIONAL CO., LTD. ADD:CMOLO Industrial Park, Hengping Rd., Henggang Street, Longgang District, Shenzhen P.C.: TEL: FAX: For more products information, please visit our website: Or follow us: Facebook Twitter Linkedin Youtube 27 / 27

OPERATING MANUAL OF SLIDING GATE TURNSTILE TPW-331EGS

OPERATING MANUAL OF SLIDING GATE TURNSTILE TPW-331EGS OPERATING MANUAL OF SLIDING GATE TURNSTILE TPW-331EGS Contents 1 General Descriptions... 1 2 Definitions... 1 2.1 Sliding Gate Turnstile... 1 2.2 Passing Modes... 2 3. Safety Precautions... 2 4 Product

More information

TPW-900ETS01. Product Manual. Intelligent Swing Gate Turnstile

TPW-900ETS01. Product Manual. Intelligent Swing Gate Turnstile TPW-900ETS01 Intelligent Swing Gate Turnstile Product Manual Contents Product Description... 1 Structure Chart... 2 Dimension Figure Unit mm... 2 Product Parameters... 3 Product Function... 3 Custom-made

More information

Tripod Turnstile CPW-450BF. Product Manual V3.2

Tripod Turnstile CPW-450BF. Product Manual V3.2 CMOLO The World Famous Leader Of Intelligent Pedestrian Access Control Tripod Turnstile CPW-450BF Product Manual V3.2 Contents Product Description... 1 Structure Chart... 2 Dimension Figure(Unit:mm)...

More information

Column swing gate turnstile CPW-321ASP

Column swing gate turnstile CPW-321ASP Column swing gate turnstile CPW-321ASP Product Manual Concise high efficient & fashionable Product Description: The passage consists of two units of CPW-321ASP by default. Single-gate passage by one unit

More information

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE. TE-700I Installation and Operating Instructions Haverland TOWELS THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE. GENERAL RECOMMENDATIONS: * Please read these installation

More information

ASL T6 / T7 / T8 / T9 FLOOR GRINDING MACHINES MANUAL

ASL T6 / T7 / T8 / T9 FLOOR GRINDING MACHINES MANUAL ASL T6 / T7 / T8 / T9 FLOOR GRINDING MACHINES MANUAL 1 Contents Preface 3 1.1 Safety Guide 4 1.2 Precautions 4 Chapter II 5 Purchase Check, Technical Parameter and Product Description 5 2.1 Purchase Check

More information

Massage Bathtub Instructions of Installation. MODEL: TOCOA SIZE: 1380*1380*610mm

Massage Bathtub Instructions of Installation. MODEL: TOCOA SIZE: 1380*1380*610mm Massage Bathtub Instructions of Installation MODEL: TOCOA SIZE: 1380*1380*610mm Dear Customer, Thank you for choosing our product. For your safe concern, please take a few minutes to read this manual before

More information

Massage Bathtub Instructions of Installation. MODEL:MT-NR1502(1504) SIZE:1500*1500*610mm

Massage Bathtub Instructions of Installation. MODEL:MT-NR1502(1504) SIZE:1500*1500*610mm Massage Bathtub Instructions of Installation MODEL:MT-NR1502(1504) SIZE:1500*1500*610mm Preparations Dear Customer, Thank you for choosing our product. For your safe concern, please take a few minutes

More information

FagronLab NP-1 UV. Negative pressure workbench. User Manual

FagronLab NP-1 UV. Negative pressure workbench. User Manual Negative pressure workbench User Manual Table of contents 1. Introduction... 3 2. Service... 3 3. Warranty... 3 4. Application range... 4 5. Main technical parameters... 4 6. Performance index... 5 Vibration

More information

Dehumidifier. Instruction Manual. Model DH-320/A

Dehumidifier. Instruction Manual. Model DH-320/A Dehumidifier Instruction Manual Model DH-320/A CONTENTS Safety Warnings 2 Operation consideration 5 Construction & controls 6 Function selection 8 Preparation for use 10 Operation 12 Maintenance 14 Continuous

More information

Electric Hand dryer. Installation and operating manual

Electric Hand dryer. Installation and operating manual Electric Hand dryer Installation and operating manual Do not attempt to install the unit yourself unless you are a trained service technician. Otherwise, this may affect safety and proper functioning of

More information

F A B G L A S S A N D M I R R O R

F A B G L A S S A N D M I R R O R Frameless Panel MSD1 FAB GLASS AND MIRROR www.fabglassandmirror.com Call: +1 888-474-2221 Office Timing: 8:30-18:00 EST Fax: (614)-334-4919 info@fabglassandmirror.com INSTALLATION INSTRUCTION SHOWER ENCLOSURE

More information

Using the Remote Control Unit

Using the Remote Control Unit Remote Control Unit (continued) SENSOR button Temperature Display Selector button Time Display Selector button ACL button (ALL CLEAR) When you press this button (use a small-tipped object such as a ballpoint

More information

Preparations MT-RT1806. Cleaning & Maintenance. Precautions

Preparations MT-RT1806. Cleaning & Maintenance. Precautions Preparations Cleaning & Maintenance 1. Use general liquid detergent and soft cloth for daily cleaning. Don't use detergent that with acetone or ammonia. Disinfector with formic acid and formaldehyde is

More information

OPTICAL TURNSTILE SYSTEM

OPTICAL TURNSTILE SYSTEM OPTICAL TURNSTILE SYSTEM Installation Instructions OTS-WNG UNPACK TURNSTILES. Remove the bolts at the ends of the turnstiles to separate from the skids and place turnstiles on the floor. With a box knife

More information

Installation Guide for inbiox60 Series Access Control Panel

Installation Guide for inbiox60 Series Access Control Panel Installation Guide for inbiox60 Series Access Control Panel Version: 1.0 Date: April, 2011 About This Manual This manual is a guide to installation and connection of the inbiox60 series access control

More information

Massage Bathtub Instructions of Installation. MODEL:MT-RT1708 SIZE:1700*800*620mm

Massage Bathtub Instructions of Installation. MODEL:MT-RT1708 SIZE:1700*800*620mm Massage Bathtub Instructions of Installation MODEL:MT-RT1708 SIZE:1700*800*620mm Preparations Dear Customer, Thank you for choosing our product. For your safe concern, please take a few minutes to read

More information

Intelligent Super Toilet AFC230 User Instruction Manual

Intelligent Super Toilet AFC230 User Instruction Manual Intelligent Super Toilet AFC230 User Instruction Manual Here, we appreciate your purchasing HCG AFC Intelligent Super Toilet Before use, please read this Instruction Manual in details. Use correctly and

More information

AM 213 Installation Introduction

AM 213 Installation Introduction EAGO Sanitary Ware Co.,Ltd. Factory Add:Shiling Development Zone,Xiaotang Town,Nanhai District,Foshan City,Guangdong,China E-mail:sales@eago.com.cn Http://www.eago.com.cn National Service Hotline:+86 800-8301359

More information

Instruction manual. Please keep safe for future reference

Instruction manual. Please keep safe for future reference 16in / 40cm Eco Pedestal Fan with 30W DC motor, Digital Display & Remote Control Model: SFDC-40101RC WARNING: Keep Batteries Out of Reach of Children 1. Swallowing may lead to serious injury in as little

More information

Dual Spin Mop Robot Cleaner

Dual Spin Mop Robot Cleaner Dual Spin Mop Robot Cleaner Copyright 2017 EVERYBOT Inc. All rights reserved. This publication is protected by copyright and all rights are reserved. No part of it may be reproduced or transmitted by any

More information

USER MANUAL. FairWind FWPC6L Pressure Cooker. Contact Us:

USER MANUAL. FairWind FWPC6L Pressure Cooker. Contact Us: USER MANUAL FairWind FWPC6L Pressure Cooker Contact Us: 1-844-528-2566 Read and Save These Instructions TABLE OF CONTENTS SPECIFICATIONS... 2 Parts List... 3 Important Safety Instructions... 4 Installation

More information

PS-2/ES Automated pack & tag machine with IndES fastening system

PS-2/ES Automated pack & tag machine with IndES fastening system English Manual PS-2/ES Automated pack & tag machine with IndES fastening system Contents 1. Introduction 2. Important Safety Instructions 3. PS-2/ES 4. Unpacking the machine 5. Setting up the machine 6

More information

Instruction Manual. for. Soldering / SMD Rework Station. For Lead-free soldering application and rework on professional SMD electronics.

Instruction Manual. for. Soldering / SMD Rework Station. For Lead-free soldering application and rework on professional SMD electronics. Instruction Manual for Soldering / SMD Rework Station LF-16 1680 For Lead-free soldering application and rework on professional SMD electronics. INTRODUCTION Thank you for purchasing Xytronic s soldering

More information

GAS RACK OVENS WITH ELECTRONIC OVEN CONTROL

GAS RACK OVENS WITH ELECTRONIC OVEN CONTROL GAS RACK OVENS WITH ELECTRONIC OVEN CONTROL MODELS DRO2G DRO2GH GAS GAS 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 937-332-3000 www.hobartcorp.com FORM 19202 Rev. D (Dec. 2003) IMPORTANT FOR YOUR SAFETY

More information

SERIES 4000 AUTO GATE MANUAL

SERIES 4000 AUTO GATE MANUAL SERIES 4000 AUTO GATE MANUAL Website: www.turnstilesecurity.com Page 1 of 27 Table of Contents 1.0 Warranty... 4 2.0 Safety... 5 2.1 Designated Use... 5 2.2 Areas of Application... 5 2.3 Warning Notes...

More information

InBio X60 Series Access Control Panel User Manual

InBio X60 Series Access Control Panel User Manual InBio X60 Series Access Control Panel User Manual Version: 1.4 Date: Nov., 2015 About This Manual This manual introduces the installation connection and user manual of the InBio X60 Series Access Control

More information

YC ON-OFF SERIES. Service Manual

YC ON-OFF SERIES. Service Manual YC ON-OFF SERIES Service Manual CONTENTS 1. Precaution... 3 1.1 Safety Precaution... 3 1.2 Warning... 3 2. Model Lists... 6 3. Dimension... 7 3.1 Indoor Unit... 7 3.2 Outdoor Unit... 11 4. Refrigerant

More information

966A AIR IONIZER. SUMITOMO 3M LIMITED Electronic Solutions Division

966A AIR IONIZER. SUMITOMO 3M LIMITED Electronic Solutions Division 966A AIR IONIZER Operation Manual Precautions...1 Safety precautions...1 Other precautions...1 Outline...2 Structure and kinds of the ionizer...2 Specifications...2 Characteristic...3 How to Install 966A

More information

Laminator ZJY Series User Manual

Laminator ZJY Series User Manual Laminator ZJY Series User Manual Eastsign International Limited Room 1818, 18/F., Shatin Galleria, 18-24 Shan Mei Street, Fotan, Shatin, N.T., Hong Kong TEL: + 852-2117 0098 FAX: + 852-2117 0099 Website:

More information

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump R-10A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFF(A/H)H, DFC(A/H) Please read the operating instructions and safety precautions carefully and thoroughly before installing and

More information

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265 Mobile Air Conditioner Use and Care Manual Part Number: 048-GM-48265 Thank you very much for selecting this new model of Portable Air Conditioner, please read this Use and Care Manual carefully before

More information

Installation and Operating Instructions

Installation and Operating Instructions Installation and Operating Instructions Models: Verso 4G Hob As part of Parmco Appliances commitment to improving and updating product ranges, we reserve the right to alter, change and update technical

More information

INSTALLATION AND USER MANUAL

INSTALLATION AND USER MANUAL INSTALLATION AND USER MANUAL Thank you for choosing our product and trusting our company. This manual is to provide you with necessary information for optimal use and maintenance, please read carefully

More information

INFORMATION ONLY READ AND SAVE THESE INSTRUCTIONS SAFETY FIRST

INFORMATION ONLY READ AND SAVE THESE INSTRUCTIONS SAFETY FIRST This information guide will help you with converting the electronics on the Comfort- Touch to Advan-Touch technology. Within this guide you will find step by step instruction on how to convert the fan,

More information

15,000 BTU Portable Air Conditioner

15,000 BTU Portable Air Conditioner Instruction Manual 15,000 BTU Portable Air Conditioner Model: HYAC15 READ AND SAVE THESE INSTRUCTIONS Please read and follow the instructions in this user manual even if you feel you are familiar with

More information

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60006PC SAFETY PRECAUTION. Canopy. Downrod. Housing. Blade. Transmitter CR2032/3V

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60006PC SAFETY PRECAUTION. Canopy. Downrod. Housing. Blade. Transmitter CR2032/3V L I G H T I N G INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:000PC SAFETY PRECAUTION PARTS & ACCESSORIES Canopy Downrod Housing IMPORTANT : PLEASE READ BEFORE INSTALLATION.. Do not connect this remote

More information

17.25 (438 mm) 37.5 (953 mm) 3.5 (89 mm) 3.0 (76 mm) 28 (711 mm) or 36 (915 mm)

17.25 (438 mm) 37.5 (953 mm) 3.5 (89 mm) 3.0 (76 mm) 28 (711 mm) or 36 (915 mm) ALVARADO Supervisor 2000-SM Optical Monitor Lane for Bi-directional Control Technical Specifications Dimensions Cabinet Length: Cabinet Height: Center Cabinet Width: End Cabinet Width: Clear Passage Width:

More information

Requests for Daily Care and Maintenance

Requests for Daily Care and Maintenance Inkjet printer SIJ-320UV Requests for Daily Care and Maintenance This machine is a precision machine equipped with extremely fine mechanisms. Especially, the nozzle surface of the heads from which the

More information

AIR CONDITIONER. Please read this owner, s manual carefully before using the air conditioner, and keep this manual for the future reference.

AIR CONDITIONER. Please read this owner, s manual carefully before using the air conditioner, and keep this manual for the future reference. Owner, s Manual AIR CONDITIONER Please read this owner, s manual carefully before using the air conditioner, and keep this manual for the future reference. CONTENTS 1. Safety Precaution-------------------------------------------------------------------------------1

More information

Portable Air-conditioner

Portable Air-conditioner Use and Care Manual Portable Air-conditioner Thank you very much for selecting this new model of Portable Air Conditioner, please read this Use and Care Manual carefully before installing and using this

More information

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS INSTRUCTIONS FOR: INFRARED IP55 HEATER MODEL:- QZWP45N Thank you for purchasing a Consort Claudgen product. Manufactured to a high standard this product will, if used according to these instructions and

More information

Pre-Installation Instructions. Installation Instruction. Installation Instructions. kah. wall. Warning. User s Manual and warranty

Pre-Installation Instructions. Installation Instruction. Installation Instructions. kah. wall. Warning. User s Manual and warranty Pre-Installation Instructions Installation Instruction User s Manual and warranty Installation plate Junction valve Check if the accessories fit your toilet dimension and then install bidet seat. Remote

More information

ES860 OPTICAL TURNSTILE INSTALLATION AND OPERATION MANUAL PRESENT CARD

ES860 OPTICAL TURNSTILE INSTALLATION AND OPERATION MANUAL PRESENT CARD ES860 OPTICAL TURNSTILE INSTALLATION AND OPERATION MANUAL To accommodate unique architectural arrangements of these bollards, their design and construction will allow their being installed in an arc shape,

More information

Installation Manual for M-G014 & M-G015

Installation Manual for M-G014 & M-G015 Installation Manual for M-G014 & M-G015 M-G014 M-G015 1 Contents 1. Electrical specifications 2. Plumbing 3. Installation of Water connections 4. Installation of Drain 5. Operation of Bathtub 6. Troubleshooting

More information

FMJ-1600-II-WARM Ving 63" Full - auto Wide Format Roll Heat Assisted Cold Laminator with Stand USER MANUAL

FMJ-1600-II-WARM Ving 63 Full - auto Wide Format Roll Heat Assisted Cold Laminator with Stand USER MANUAL FMJ-1600-II-WARM Ving 63" Full - auto Wide Format Roll Heat Assisted Cold Laminator with Stand USER MANUAL I. Specifications Heating Mode: Upper roller heating Heating power: 1500W Rated Power: 16A II.

More information

INSTALLATION INSTRUCTION for ceiling fan

INSTALLATION INSTRUCTION for ceiling fan INSTALLATION INSTRUCTION for ceiling fan F8203 Installation & Operating Instructions for the Parrotuncle Owner s Installation,Manual Motor is core parts of the fan and the most expensive in all the components.

More information

Checking the components Safety information Operating the product Other information

Checking the components Safety information Operating the product Other information 1 Feature of your product Always provide powerful elimination performance 2/4 Samsung SPi device has been applied on the left/right side of the product for quick and powerful elimination performace. Luxurious

More information

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER Instruction Manual Model AMB-12H PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USING THIS UNIT. Table of Contents 1. SAFETY WARNINGS 2 2. CONSTRUCTION...

More information

CRISTAL Built-in Dish Sterilizer Instruction Manual

CRISTAL Built-in Dish Sterilizer Instruction Manual CRISTAL Built-in Dish Sterilizer Instruction Manual Model No.: D36DSS Version Number: 01 Revision Date: September 2014 Dear user: Thank you for your purchase of CRISTAL built-in dish sterilizer! Please

More information

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE 2 GLEC-6 - Installation and maintenance CONTENTS 1 Important information... 3 2 Safety notes... 3 3 Technical description...4 4 Transport... 6 5

More information

GLEB Kitchen exhaust fan

GLEB Kitchen exhaust fan GLEB Kitchen exhaust fan Installation and Maintenance??.1.2013 Contents 1. Important information 2. Safety notes 3. Technical description 4. Transport 5. Mounting instructions 6. Commissioning 7. Maintenance

More information

4040 FM 535 F :

4040 FM 535 F : OVERVIEW OPTICAL TURNSTILE SYSTEM HALF HEIGHT BARRIER TURNSTILES MODEL OTS-HHB-6 The OTS-HHB monitors through-beam infrared sensors, access control contacts, and barrier posion sensors to control the moon

More information

Instruction Manual. for. Intelligent Temperature Controlled Soldering Station LF-2000 (U)

Instruction Manual. for. Intelligent Temperature Controlled Soldering Station LF-2000 (U) Instruction Manual for Intelligent Temperature Controlled Soldering Station LF-2000 (U) For Lead-free soldering application and rework on professional SMD electronics. 1 INTRODUCTION Thank you for purchasing

More information

Model S-530 Coin Sorter / Value Counter Operating Manual

Model S-530 Coin Sorter / Value Counter Operating Manual Model S-530 Coin Sorter / Value Counter Operating Manual Table of Contents Using the Product Safely... 2 About the Warning Stickers and Points of Warning/... 2 Warnings... 3 s 4 Names of the Machine Parts....

More information

HX-80NRAM. High Mount Outdoor Detector

HX-80NRAM. High Mount Outdoor Detector Battery operated with 2 PIRs and HX-80NRAM anti-masking Battery operated Battery saving logic Compatible with most wireless transmitter Long distance detection area (24.0 m) Flexible detection area setting

More information

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION INSTRUCTION MANUAL FOR MODEL(S): All Variations of the FF-6 All Variations of the FF-7 & All Variations of the SCR-600L/SCR-600BL ALL-REFRIGERATOR Write the

More information

PORTABLE AIR CONDITIONER OWNER S MANUAL

PORTABLE AIR CONDITIONER OWNER S MANUAL PORTABLE AIR CONDITIONER OWNER S MANUAL ASSEMBLY AND OPERATING INSTRUCTIONS MODELS: JHS-A018-10KR SKU#: 130004 JHS-A018-12KRH SKU#: 130005 WARNING: Read and follow all warnings and instructions in this

More information

ISHIDA CO., LTD. Do not carry out installation, operation, service or maintenance until thoroughly understanding the contents of this manual.

ISHIDA CO., LTD. Do not carry out installation, operation, service or maintenance until thoroughly understanding the contents of this manual. Do not carry out installation, operation, service or maintenance until thoroughly understanding the contents of this manual. Keep this manual available at all times for installation, operation, service,

More information

Dehumidifier User Manual. (For the series of DP40~DP70)

Dehumidifier User Manual. (For the series of DP40~DP70) Dehumidifier User Manual (For the series of DP40~DP70) Content I. Please read immediately... 1 II. Application... 2 III. Features... 2 IV. Technical Parameters... 3 V. Overall Dimension... 4 VI. Installation

More information

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005) RC801/803/805-480B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005) 1. Cautions Please read the following notices carefully before installing and using the device,

More information

ELIMINOSTAT DC-ESR-CL-S2

ELIMINOSTAT DC-ESR-CL-S2 Static Clean Instruction Manual DC Voltage Application Method Static Eliminators Static Eliminator with Integral Power Supply ELIMINOSTAT DC-ESR-CL-S2 Thank you for purchasing the Static Eliminator ELMINOATAT

More information

Table of Contents. Notice: Any maintenance should be returned to the dealer or factory! Attention: Please read this instruction carefully before use.

Table of Contents. Notice: Any maintenance should be returned to the dealer or factory! Attention: Please read this instruction carefully before use. English Table of Contents 1. Accessories ------------------------------------------------------------------------1 2. Introduction--------------------------------------------------------------------------2

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

Owner s Manual Super-Slim Four-Way Cassette

Owner s Manual Super-Slim Four-Way Cassette CASSETTE- TYPE AIR CONDITIONER Owner s Manual Super-Slim Four-Way Cassette IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this

More information

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER Owner s Manual Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 IMPORTANT NOTE: Read this manual carefully before installing

More information

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL IMPORTANT WARNING WHEN THE CO MONITOR IS CORRECTLY INSTALLED AND MAINTAINED, IT MONITORS THE LEVEL OF CARBON MONOXIDE IN ITS SURROUNDINGS..

More information

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum

More information

3. Thermal switch (70 o C thermostat) with a 3 m connection cable

3. Thermal switch (70 o C thermostat) with a 3 m connection cable Essence pump Installation and operating manual Contents page page 1. Purpose and operating principle 1 7. Operation 6 2. Safety instructions 2 8. Feed volume setting 7 3. Technical data 3 9. Maintenance

More information

KSD-35 DR11 KUE-35 DVN11

KSD-35 DR11 KUE-35 DVN11 FLOOR-STANDING TYPE AIR CONDITIONER Owner s Manual Floor-Standing Type KSD-35 DR11 KUE-35 DVN11 IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit.

More information

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V L I G H T I N G INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:000BZGTGLD SAFETY PRECAUTION PARTS & ACCESSORIES Canopy Downrod Housing WARNING To make sure power is off before attempting installation. WARNING

More information

PolySprint. Operation Manual PSM-NIT-13004E. Follow this manual when using Nitta PolySprint Heat Press.

PolySprint. Operation Manual PSM-NIT-13004E. Follow this manual when using Nitta PolySprint Heat Press. PSM-NIT-13004E PolySprint Heat Press NPS-1205H1/H2 Operation Manual Follow this manual when using Nitta PolySprint Heat Press. Please pass this manual to PolySprint Heat Press users for a safe and trouble-free

More information

SU2000-SM. model OPTICAL TURNSTILES DESCRIPTIVE SPECIFICATIONS TYPICAL INSTALLATION SITES COMMON APPLICATIONS ALVARADOMFG.COM

SU2000-SM. model OPTICAL TURNSTILES DESCRIPTIVE SPECIFICATIONS TYPICAL INSTALLATION SITES COMMON APPLICATIONS ALVARADOMFG.COM model The Supervisor 2000-SM is our thinnest barrier-free turnstile. Its compact form is well suited for applications where space is at a premium. COMMON APPLICATIONS Employee and Visitor Access Control

More information

Infrared Portable Space Heater

Infrared Portable Space Heater Infrared Portable Space Heater 1500 Watts with Two Heat Settings Automatic Thermostat Tip-Over Switch Room Temperature LED Display Precision Temperature Control Easy Push-Button Controls Remote Control

More information

Portable Air-conditioner Use and Care Manual

Portable Air-conditioner Use and Care Manual Portable Air-conditioner Use and Care Manual Part Number: 048-GM-48266 Thank you very much for selecting this new model of Portable Air Conditioner, please read this Use and Care Manual carefully before

More information

INSTRUCTION MANUAL FOR

INSTRUCTION MANUAL FOR INSTRUCTION MANUAL FOR LF-3000 High Frequency Soldering Station 1 INTRODUCTION Thank you for purchasing Xytronic s high heat capacity soldering station the best solution for your soldering equipment needs

More information

Desoldering Tool. Instruction Manual

Desoldering Tool. Instruction Manual Desoldering Tool Instruction Manual Thank you for purchasing the Hakko 472D desoldering tool with digital temperature display. Please read this manual before operating the Hakko 472D. Keep this manual

More information

Installation Guide BUILT-IN SXS REFRIGERATOR UPSXB2627**

Installation Guide BUILT-IN SXS REFRIGERATOR UPSXB2627** Installation Guide BUILT-IN SXS REFRIGERATOR UPSXB2627** www.thesignaturekitchen.com 2 Contents 1. Precaution before installation... 3 2. Product and Cutout dimension... 4 3. Precaution when moving the

More information

DH-Direct Fired Poultry Farm Diesel Heater

DH-Direct Fired Poultry Farm Diesel Heater DH-Direct Fired Poultry Farm Diesel Heater Comparison of Diesel Heater to Gas Heater Diesel LPG Gas LPG Gas KW 43 70 120 Fuel consumption/hr 3 5.1 8.8 Heat output 37000 60000 100000 Cost of fuel/lit or

More information

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series Installation CRS-2/IR, CRS-3/IR Express Crescent Lavatory System CRS-Series CRS-3/IR/LSD Complies with Texas Accessibility Standards (TAS) for Juvenile Height applications. Table of Contents Dimensions...2

More information

Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual

Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual Version 1.5 1 CONTENTS CHAPTER 1 GENERAL INTRODUCTION...3 1. Preface... 3 2. Product Introduction... 3

More information

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117 Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel Revision E 61117 CAUTION: (Read This First) This panel has been designed to make it nearly bullet proof to mistakes made when wiring

More information

DIGITAL ULTRASONIC HUMIDIFIER WITH HUMIDISTAT

DIGITAL ULTRASONIC HUMIDIFIER WITH HUMIDISTAT DIGITAL ULTRASONIC HUMIDIFIER WITH HUMIDISTAT To prolong the life of this humidifier, using distilled water is highly recommended. NEVER add fragrance or oil in the water, it will cause the machine to

More information

POLYMIX PX-IG 2000 Operating Instructions

POLYMIX PX-IG 2000 Operating Instructions POLYMIX PX-IG 2000 Operating Instructions Voltage D 100-120V, 50/60 Hz D 210-250V, 50/60 Hz Please check that the voltage is correct and corresponds with the nameplate on the back of the machine. Manual

More information

Bi-Directional Barrier Arm Turnstile

Bi-Directional Barrier Arm Turnstile ES831 *Custom model shown in stone and bronze Bi-Directional Barrier Arm Turnstile Model ES831 Optical Turnstiles > ES831 Series > Optical Turnstiles w/ Barrier Arms > Design Overview The ES831 bi-directional

More information

Model: DC-159. Instruction Manual

Model: DC-159. Instruction Manual Model: DC-159 Instruction Manual Attention: This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge

More information

WIRELESS WATER CONTROLLER. MC-503RC Installation and Operation Manual

WIRELESS WATER CONTROLLER. MC-503RC Installation and Operation Manual WIRELESS WATER CONTROLLER MC-503RC Installation and Operation Manual Suitability Suitable for the following Rinnai continuous flow water heaters with Quick Connect cable connector and controllers: Water

More information

Owner's Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS 40MAQ High Wall Ductless System Sizes 09 to 36 Owner's Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PART NAMES... 3 FUNCTION BUTTONS... 4 DISPLAY PANELS... 5 REMOTE CONTROL... 6

More information

GRANDE OWNER S MANUAL

GRANDE OWNER S MANUAL LE GRANDE OWNER S MANUAL The blades in each pack are matched for equal weight to assure smooth fan operation. If more than one fan is being installed, be careful not to mix blades from different cartons.

More information

PROFESSIONAL S2 SAFE USER GUIDE ELECTRONIC LOCK USER GUIDE.

PROFESSIONAL S2 SAFE USER GUIDE ELECTRONIC LOCK USER GUIDE. USER GUIDE PROFESSIONAL S2 SAFE ELECTRONIC LOCK USER GUIDE www.chubbsafes.com Chubb is owned by Chubb plc and is a registered trademark used under license General Description The lock is operated by a

More information

ARLEC. User Instructions

ARLEC. User Instructions ARLEC User Instructions Used for model:ealc070, EALC090, EALC125, EALC150, EALC180 (Picture is only for reference purposes only) Products in the carton: Once open the carton, pls. check everything is complete

More information

CONTROLS INSTRUCTIONS MANUAL ENGLISH

CONTROLS INSTRUCTIONS MANUAL ENGLISH CONTROLS INSTRUCTIONS MANUAL ENGLISH Table of Contents 1. Introduction of the Innova Controls 3 1.1 Precautions 3 2. Operating Instructions 2.1 Quick Start 4 2.2 Direction of Use 5 2.2.1 Heater on 5 2.2.2

More information

Dahua 2-inch HDCVI Speed Dome Installation Manual Version Dahua Technology CO., LTD

Dahua 2-inch HDCVI Speed Dome Installation Manual Version Dahua Technology CO., LTD Dahua 2-inch HDCVI Speed Dome Installation Manual Version 1.0.0 Dahua Technology CO., LTD Table of Contents 1 HDCVI SPEED DOME INSTALLATION... 1 1.1 Installation Environments... 1 1.2 Check installation

More information

ULTRASONIC OIL LEVEL MONITOR & ALARM

ULTRASONIC OIL LEVEL MONITOR & ALARM ULTRASONIC OIL LEVEL MONITOR & ALARM How it works The oil alarm on tank unit checks the oil level approximately once every minute. Under normal conditions it communicates this level to the receiver approximately

More information

SHORT WAVE INFRARED PANEL DRYER

SHORT WAVE INFRARED PANEL DRYER INSTRUCTIONS FOR: SHORT WAVE INFRARED PANEL DRYER MODEL: IR3000 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and

More information

SCR100 User Manual. Version:1.1 Date:Dec 2009

SCR100 User Manual. Version:1.1 Date:Dec 2009 SCR100 User Manual Version:1.1 Date:Dec 2009 Introduction: This document mainly introduces the installations and connections of SCR100 products, and the brief operations about attendance software. Important

More information

SERVICE MANUAL MULTI DECK 60 HOT MERCHANDISER MULTI DECK 100 HOT MERCHANDISER MULTI DECK 120 HOT MERCHANDISER CLASSIC DECK HOT MERCHANDISER

SERVICE MANUAL MULTI DECK 60 HOT MERCHANDISER MULTI DECK 100 HOT MERCHANDISER MULTI DECK 120 HOT MERCHANDISER CLASSIC DECK HOT MERCHANDISER SERVICE MANUAL MULTI DECK 60 HOT MERCHANDISER MULTI DECK 100 HOT MERCHANDISER MULTI DECK 120 HOT MERCHANDISER CLASSIC DECK HOT MERCHANDISER Classic Deck Hot Multi Deck 60 Multi Deck 100 Multi Deck 120

More information

Installation and Operation Manual

Installation and Operation Manual ! Please read this manual carefully before use. M-G301 Installation and Operation Manual! 1 Table of Contents 1. Important Notice------------------------------------------------------2 2. Technical parameters

More information

SAFETY AND OPERATING MANUAL

SAFETY AND OPERATING MANUAL SAFETY AND OPERATING MANUAL HOT WATER ELECTRIC WATER BLASTERS Read Safety & Operating Instructions Before Commencing Operation THESE INSTRUCTIONS MUST BE READ AND ADHERED TO BEFORE OPERATING THIS MACHINE.