TS93 EMF SERIES. INSPK NO Rev.03/10

Size: px
Start display at page:

Download "TS93 EMF SERIES. INSPK NO Rev.03/10"

Transcription

1 TS93 EMF SERIES 1 Each hold open (HO) unit contains a door closer and track assembly with hold open solenoid. The unit can be connected directly to a fire control panel. 1) Read the entire instruction sheet prior to installation and refer to NFPA 72E. Standards may be obtained from THE NATIONAL FIRE PROTECTION ASSOCIATION, Batterymarch Park, Quincy, MA., ) Reference the unit carton for mounting style and voltage. 3) Prepare door and frame for fasteners using the appropriate template. Mark, drill and tap holes as indicated. If surface wiring is used, omit 7/8" hole for wire access. CAUTION: SEX NUTS ARE REQUIRED FOR ATTACHMENT OF COMPONENTS TO UNREINFORCED DOORS AND TO WOOD OR PLASTIC FACED COMPOSITE TYPE FIRE DOORS, UNLESS AN ALTERNATIVE METHOD IS IDENTIFIED IN THE INDIVIDUAL DOOR MANUFACTURER'S LISTINGS. 2 Attach mounting plate to door, using lower four holes in plate. Use upper four holes for optional mounting. Arrows on plate face the top of the door. (4) METAL DOORS WOOD DOORS TS93T AND TS93DE INS NO. INSPK NO Rev.03/ PAGE 1 of 7 Rev. 03/10

2 3 Attach closer to mounting plate. (8) TS93T AND TS93DE 4 Remove wire access plug according to the installation type. Any access hole can be used for surface wiring installations. Three access wire holes on optional surface wired units only. T & DE (RH) NO TOP PLUG ON PT MOUNTS T & DE (LH) SURFACE WIRING Install track to frame. TS93T and TS93DE Install with wire access plugs toward latch edge of door using (2) 1/4-20 x 2" metal or (2) No. 14 x 2-3/4" wood screws. Route wires from frame through appropriate wire access hole in track, being careful not to pinch wires during installation. (2) (2) CONTINUED NEXT PAGE... INS NO PAGE 2 of 7 Rev. 03/10

3 STEP CONTINUED... Install PT track to soffit with wire access plugs toward hinge. Install with 1/4-20 x /8" metal or No /4" wood and 1/4-20 x 2" metal or No. 14 x 2-3/4" wood screw as shown. Route wires from frame through appropriate wire access hole in track, being careful not to pinch wires during installation. ( DO NOT INSTALL ON HINGE SIDE IN THIS STEP) C HINGE 6 Slide wiring connection cover to allow access to wire connections. Determine power supply and unit voltage type: 24VAC, 24VDC or 120VAC. CAUTION (DO NOT CONNECT 120VAC TO A 24 VOLT UNIT TYPE.) Connect power supply wires to terminal block as shown (Terminal Block can be removed for easier access). Be sure to use ground screw for power supply ground wire when supplying 120VAC. Return wiring connection cover to cover wire connections. CAUTION: Improper voltage to unit, will result in damage to unit and void warranty. All wiring must comply with national, state and local electrical codes. SOLENOID WIRES GROUND SCREW TO U.L. LISTED ALARM CONTROL UNIT OR SMOKE DETECTOR INCOMING POWER CONNECTION WIRE CONNECTION COVER TERMINAL BLOCK THIS CONNECTION IS NOT POLARITY DEPENDENT. 7 ONLY Insert wire connection cover into track, align end cap in end of track. Install remaining screw as shown using 1/4-20 x 2" metal or No. 14 x 2-3/4" wood screw. TO U.L. LISTED ALARM CONTROL UNIT OR SMOKE DETECTOR WIRE CONNECTION COVER INS NO PAGE 3 of 7 Rev. 03/10

4 8 TS93T Attach arm to pinion of closer and secure arm with pinion screw. TS93DE Attach arm to pinion of closer and secure arm with pinion screw. TS93DE Attach arm to pinion of closer. With door in closed position, rotate spindle approximately 11 with wrench and hold in place. Place arm on spindle parallel to door and secure arm with pinion screw Attach arm to slide shoe. Use 3/16 inch hex head wrench. INS NO PAGE 4 of 7 Rev. 03/10

5 10 Adjust sweep, latch and backcheck or delayed action cycles. CAUTION: DO NOT REMOVE VALVES. DECREASE INCREASE A - SWEEP speed from maximum opening to 0. B - LATCH speed from approx. 7 to 0.-(INCREASE ONLY) A B LATCH RANGE SWEEP RANGE TS93 SZ. 1- BACKCHECK (INTENSITY) OR DELAYED ACTION (TIME) A INCREASE DECREASE C - BACKCHECK cushion effect. D - DELAY speed from approx. 120 to 70. BACKCHECK RANGE CAUTION: DO NOT CLOSE VALVE COMPLETELY. DELAY RANGE DELAYED ACTION IS AN OPTIONAL FEATURE. D C TS93 SZ. 6 D C B 11 Adjust spring tension, if required. Closer is normally supplied with minimum spring setting. Clockwise turns increase spring tension. MAXIMUM NUMBER OF TURNS - 18 CAUTION: DO NOT OVERTIGHTEN BARRIER-FREE OPENINGS - Adjust only if more spring tension is required to positively close and latch door. NON-BARRIER-FREE OPENINGS: TS93 SIZE 1- - Adjust according to chart. TS93 SIZE 6 - Adjust only if more spring tension is required to positively close and latch door. ULC LABELED UNITS "ONLY" - INCREASE DECREASE Adjust according to chart. DOOR WIDTH INT. EXT. 2'6" --- 3' 2'6" 3'6" 3' 4' 3'6" FULL TURNS OF SPRING ADJUSTER CLOSER SIZE CLOSER TYPE TS93 SZ. 1- TS93 SZ.6 MAX. DOOR WEIGHT (LBS) SPRING FULL TURNS SIZE OF SPRING ADJUSTER Hold open position is preset at approximately 90. Loosen set screws using 3/32 inch hex wrench slide hold open device for desired position. Retighten set screws securely. HOLD OPEN DEVICE GREATER HOLD OPEN ANGLE LESS HOLD OPEN ANGLE HOLD OPEN SET SCREWS POWER MUST BE SUPPLIED TO RESET POSITION. INS NO PAGE of 7 Rev. 03/10

6 13 Snap cover onto backplate and attach cover caps to closer. COVER CAPS COVER REMOVE TAB REMOVE TAB SPRING ADJ. END VALVE ADJ. END 14 Final Installation and Test. 1) After the installation is completed, recheck all the connections. Then apply power to the units. 2) Open door so slide block engages with the hold open assembly. 3) Advise fire officials prior to testing the unit. 4) Activate the system into alarm so solenoids release and the doors close. ) If the closer is used in conjunction with a dectectored unit, trip the test switch of the main closer dectector as explained in the test procedure for that unit. After a short time delay, the hold open solenoid of both units will release and the doors will closel. Resetting the test switch will allow the units to return to standby. 1 IMPORTANT: THE UNIT MUST BE TESTED AFTER THE INSTALLATION, BY THE END USER, TO ASSURE THAT THE DOOR CLOSER UNITS FUNCTION PROPERLY WHEN THE ALARM SYSTEM IS ACTIVATED. THE ENTIRE SYSTEM MUST ALSO BE TESTED PERIODICALLY AFTER THE INITIAL INSTALLATION TEST, IN CONJUNCTION WITH THE TESTING OF THE FIRE ALARM SYSTEM. THE END USER IS ALOS RESPONSIBLE FOR THE ADJUSTMENTS AND MAINTENANCE TO RETAIN THE SYSTEM IN WORK ORDER 16 OPERATION: NORMAL - The closer unit's solenoid will be energized across a normally closed alarm contact applying, 24VDC, 24VAC or 120VAC power supply based on unit voltage. FIRE ALARM - When the alarm sounds, the alarm contact will open and interrupt current to the solenoid which releases the hold open and allows the door closer to shut the door ELECTRICAL SPECIFICATIONS: Voltage Input - 24VDC +10% - 1% Maximum Input Current - 24VDC 170mA - 24VAC +10% - 1% - 24VAC 170mA - 120VAC +10% - 1% - 120VAC 33mA INS NO PAGE 6 of 7 Rev. 03/10

7 17 Slide wiring connection cover to allow access. Attach bracket and assemble bypass switch. OPTIONAL BYPASS SWITCH TRACK (T) MOUNT: WIRE CONNECTION COVER Determine power supply and unit voltage type: 24VAC, 24VDC or 120VAC. CAUTION (DO NOT CONNECT 120VAC TO A 24 VOLT UNIT TYPE.) Connect power supply wires, one to terminal block one to bypass switch. connect other bypass switch wire to terminal block. (Terminal Block can be removed for easier access). Be sure to use ground screw for power supply ground wire when supplying 120VAC. Return wiring connection cover to cover wire connections. CAUTION: Improper voltage to unit, will result in damage to unit and void warranty. BYPASS SWITCH GROUND SCREW TO U.L. LISTED ALARM CONTROL UNIT OR SMOKE DETECTOR INCOMING POWER CONNECTION All wiring must comply with national, state and local electrical codes. WIRE CONNECTION COVER TERMINAL BLOCK THIS CONNECTION IS NOT POLARITY DEPENDENT. TERMINAL BLOCK 18awg MAX. OPTIONAL BYPASS SWITCH PUSH TRACK (PT) MOUNT: CAUTION: Improper voltage to unit, will result in damage to unit and void warranty. NOTES: All wiring must comply with national, state and local electrical codes. If installing the optional bypass switch, install assembly on the end of the track as shown. Fasten track to door frame with the screws provided. Fasten the end cap assembly with metal or wood screws provided. Connect the switch with wire nuts and slide the cover in place. Place end cap in extension piece and fasten to fame with screw provided. INS NO PAGE 7 of 7 Rev. 03/10

TS93 EMR WITH SMOKE DETECTOR

TS93 EMR WITH SMOKE DETECTOR TS EMR WITH SMOKE GENERAL DESCRIPTION Each TS EMR series unit contains a door closer, hold open electromagnet and smoke detector. The unit can be used as a single installation or as a series of singles

More information

8600 EMR SERIES. INSPK NO Rev.06/ INS NO. GENERAL DESCRIPTION

8600 EMR SERIES. INSPK NO Rev.06/ INS NO. GENERAL DESCRIPTION 00 EMR SERIES GENERAL DESCRIPTION Each 00 EMR series unit contains a door closer, hold open electromagnet and smoke detector. The unit can be used as a single installation or as a series of singles powered

More information

MODEL /4" Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload

MODEL /4 Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload 2900 FIREGUARD Electromechanical Closer-Holder Device Models 12-2960, 9-2960 and 2960 Multipoint Hold Open with Rigid Arms Pull (Hinge) Side Installation Instructions CAUTION: FAILURE TO INSTALL OR ADJUST

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D2 MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D2 GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

DC300 Rack and pinion door closer with link arm

DC300 Rack and pinion door closer with link arm Rack and pinion door closer with link arm ASSA ABLOY Rack and pinion closer with link arm L190 Certified in compliance with EN 114, size 3-6 Suitable for fire and smoke protection doors For single action

More information

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector Wiring Instructions for the 900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector CAUTION: FAILURE TO INSTALL OR ADJUST PROPERLY MAY RESULT IN INJURY OR

More information

MANUAL RESET ALARM RELEASE BOX

MANUAL RESET ALARM RELEASE BOX MANUAL RESET ALARM RELEASE BOX (For 100~240VAC or 24VAC or 24VDC) INSTRUCTION MANUAL WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

2408/2900. Fire Guard

2408/2900. Fire Guard 2408/2900 Fire Guard Table of Contents Features and Additional Fire Opening Devices... 1 2408 Single-Point Hold Open Applications and Mounting Details... 2 2408 Track Assemblies, Arms and Components...

More information

Layout S. 6 DORMA CI-2012 Englisch Stand

Layout S. 6 DORMA CI-2012 Englisch Stand TS 3 V Door Closer TS 3 V Door Closer Easy to fit, economical and with adjustable closing force Simple, easy installation, and guaranteed quality. Tested to EN 54 Specially designed for internal doors,

More information

DC300 Rack and pinion door closer with link arm

DC300 Rack and pinion door closer with link arm Rack and pinion door closer with link arm ASSA ABLOY Rack and pinion closer with link arm L190 Certified in compliance with EN 114, size 3-6 Suitable for fire and smoke protection doors For single action

More information

EHT/EHTD. Electromechanical Closer-Holder Release Devices

EHT/EHTD. Electromechanical Closer-Holder Release Devices 351 EHT/EHTD Electromechanical Closer-Holder Release Devices Copyright 2003-2009, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Table of Contents Table of Contents Page

More information

7200 Series. Electromechanical Closer/Holder Releasing Devices

7200 Series. Electromechanical Closer/Holder Releasing Devices 7200 Series Electromechanical Closer/Holder Releasing Devices INTRODUCTION The 7200 Series Electromechanical Closer/Holders combine the functions of an electromechanical door holder with the 7700 series

More information

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved Fire Guard SARGENT Manufacturing Company 2004, 2007 All rights reserved Fire Guard Table of Contents Features and Additional Fire Opening Devices............................1 2408 Single-Point Hold Open

More information

DC200 Rack and pinion door closer with link arm

DC200 Rack and pinion door closer with link arm 114 Door closers Rack and pinion door closer with link arm ASSA ABLOY Certified in compliance with EN 114, size 2-4 Suitable for fire and smoke protection doors For single action doors up to 10 mm wide

More information

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual prior to installing and/or servicing this product. As with all releasing device

More information

DS160/161 Request To Exit PIR sensors Installation Instructions

DS160/161 Request To Exit PIR sensors Installation Instructions DS160/161 Request To Exit PIR sensors Installation Instructions 1.0 Description The DS160/161 is a passive-infrared (PIR) detector designed for request to exit (REX) interior applications. It is UL Listed

More information

2409/2900. Fire Guard

2409/2900. Fire Guard 2409/2900 Fire Guard Table of Contents Features and Additional Fire Opening Devices... 1 2409 Single-Point Hold Open Applications and Mounting Details... 2 2409 Track Assemblies, Arms and Components...

More information

An ASSA ABLOY Group brand Series. Electromechanical Closer-Holder Releasing Device

An ASSA ABLOY Group brand Series. Electromechanical Closer-Holder Releasing Device An ASSA ABLOY Group brand 4200 Series Electromechanical Closer-Holder Releasing Device introduction The 4200 Series Electromechanical Closer-Holders combine the functions of an electromechanical door holder

More information

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION: RELEASE DEVICES MADE IN THE U.S.A. RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: The "WPS" World Power Series, Time Delay Release

More information

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors Hinge Edge of Door Hinge Edge of Door Wiring Instructions for the Sargent 0 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector CAUTION: FAILURE TO INSTALL

More information

Installation Instructions

Installation Instructions Installation Instructions Self-Cleaning Radiant Electric Drop-In Range JDP47, JD968, JD900 If you have questions, call 1.800.GE.CARES or visit our website at: ge.com Before You Begin Read these instructions

More information

120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE.

120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE. 00000 (0) 00 PowerMatic Low Energy Power Operator Wiring Instructions 0 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE. REQUIREMENTS: U.L.

More information

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

THE SS90 SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL S S S S S S OLID TATE ECURITIES, INC S S 90 SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED 99Y9 RESET U L RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

5900 SERIES Low Energy Power Operator

5900 SERIES Low Energy Power Operator Low Energy Power Operator introduction The Norton 5900 Series is a full-featured, extremely quiet, low energy door operator designed for moderate to high traffic doors. This cost-effective operator is

More information

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

SOLID STATE SECURITIES, INC. THE SS90 SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL S S S S S S LISTED L * PATENT PENDING S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT U 99Y9 RESET RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

ASSA ABLOY Series Power Operator Installation and Instruction Manual 6060 / Reveal. Adjusting Rod (08-13)

ASSA ABLOY Series Power Operator Installation and Instruction Manual 6060 / Reveal. Adjusting Rod (08-13) 6000 Series Operator Installation and Instruction Manual ASSA ABLOY 6060 / 6070 1 3 5 4 6 2 Item No. Description 1 2 Motor (6000M) Cover (6000COV) 3 4 Control Inverter (6000IN) Supply 24VDC (6000SUP) Reveal

More information

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL Firefly II Multi Voltage RELEASE DEVICES Firefly II & IIB-MV INSTALLATION MANUAL GENERAL DESCRIPTION: S/N The The Cookson Company Firefly II-MV time delay release devices are designed for use on rolling

More information

An ASSA ABLOY Group brand Series. Architectural Door Closers

An ASSA ABLOY Group brand Series. Architectural Door Closers An ASSA ABLOY Group brand 2700 Series Architectural Door Closers introduction Yale 2700 series architectural door closers are ideal for commercial applications where ease of use, installation and aesthetics

More information

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door CAUTION Hinge Edge of Door Wiring Instructions Checkmate Series with Single Point Hold-Open Combination Door Closer-Holder and Releasing Device with or without Integral Smoke Detector INSTALLER: LEAVE

More information

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA) INSTRUCTION MANUAL AlarmGard Chain Operator (Model FCA) & AlarmGard Crank Operator (Model FKA) WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Drop-In Range JDS28, JDP39 Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com BEFORE YOU BEGIN Read these instructions carefully and completely.

More information

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: These Time Delay Release Devices are U.L. Listed, Canadian Listed,

More information

DS160/DS161 Request To Exit PIR sensors Installation Instructions

DS160/DS161 Request To Exit PIR sensors Installation Instructions DS160/DS161 Request To Exit PIR sensors Installation Instructions 1.0 Description The DS160 is a Passive Infrared Detector (PIR) which is UL Listed as an Access Control Device under the UL 294 Standard.

More information

DC340 Rack and pinion door closer with guide rail or link arm

DC340 Rack and pinion door closer with guide rail or link arm 128 Door closers Rack and pinion door closer with guide rail or link arm ASSA ABLOY Available with heigth-adjustable guide rail G195 or standard guide rail G193 Certified in compliance with EN1154, size

More information

5900 Series X-in Low Energy Power Operator

5900 Series X-in Low Energy Power Operator 5900 Series X-in Low Energy Power Operator INTRODUCTION The Norton 5900 Series X-in is a full-featured, extremely quiet, low energy door operator designed for moderate to high traffic doors. This cost-effective

More information

DORMA. Free Swing and Hold-open Solutions for Fire Doors. An alternative to Fire door keep shut

DORMA. Free Swing and Hold-open Solutions for Fire Doors. An alternative to Fire door keep shut DORMA Free Swing and Hold-open Solutions for Fire Doors An alternative to Fire door keep shut Permanently closed fire doors can present an obstacle to building occupants, particularly on circulation routes,

More information

Installation Instructions

Installation Instructions 4 3 Installation Instructions Self Cleaning Free-Standing Electric Range EER2000, EER3000, EER3001, EER3002, JBP10, JBP24, JBP26, JBP30, JBP35, JBP48, JBP64, JBP66, JBP68, JBP69, JBP71, JBP78, JBP80, JBP82,

More information

SPECIFICATIONS. Contents List

SPECIFICATIONS. Contents List INSTALLATION INSTRUCTIONS FOR PB-SA PUSH BUTTON SYSTEM ABORT The information contained in this installation instruction is a quick reference guide. For detailed system information refer to the panel manufacturers

More information

3480/RCH SERIES INSTALLATION INSTRUCTIONS

3480/RCH SERIES INSTALLATION INSTRUCTIONS 3480/RCH SERIES INSTALLATION INSTRUCTIONS NOTE: If plaster frame is required for installation order it as an option. ATTENTION: Read carefully before attempting to install or operate the heater. GENERAL

More information

Modular Fillerplate Subassembly P/N: X Endcap P/N: Strike *, P/N: " Narrow Stile Plastic Template. Mortise.

Modular Fillerplate Subassembly P/N: X Endcap P/N: Strike *, P/N:  Narrow Stile Plastic Template. Mortise. 103182 June 3, 2010 Delayed Egress Parts Check List V40 EM Centercase/Pushpad Modular SubAssembly P/N: 104374-X Plastic Template Use for ease of installation P/N: 103806-X Detex Corporation, 302 Detex

More information

Wiring Instructions (01-09)

Wiring Instructions (01-09) CAUTION Wiring Instructions 0--00-0 (0-0) Power Track Series with Single Point Hold-Open Electromechanical Releasing Device with Multi-Point Hold- Open TO PREVENT ELECTRICAL SHOCK AND EQUIPMENT DAMAGE,

More information

HighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75

HighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75 General Information: is intended for linear lighting in storerooms, walk-in coolers, indoor and outdoor soffits, outdoor canopies, car washes, and a variety of other lighting applications. Do not mount

More information

Installation. Built-in Full Height Wine Cellar VCWB301

Installation. Built-in Full Height Wine Cellar VCWB301 Installation Built-in Full Height Wine Cellar VCWB301 Table of Contents Warnings & Important Information _ 3 Dimensions _ 5 Specifications _ 6 Cutout Dimensions 7 Cabinet Information _ 8 Cabinet Information

More information

SK-Duct Air Duct Smoke Detector

SK-Duct Air Duct Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS I56-3432-001R 12 Clintonville Road Northford, CT 06472 203.484.7161; Fax: 203.484.7118 SK-Duct Air Duct Smoke Detector http://www.silentknight.com Specifications

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL Distinctive Lighting and Ceiling Fans CEILING FAN OWNER'S MANUAL MODEL: 52CW2L5-GM 52CW2L5-OBB READ AND SAVE THESE INSTRUCTIONS FOR CEILING FAN PARTS AND SERVICE, CALL 1-877-902-5588 FAN RATING AC 120V.

More information

INSTALLATION AND MAINTENANCE

INSTALLATION AND MAINTENANCE INSTALLATION AND MAINTENANCE DH100ACDCIA & DH100ACDCPA Air Duct Smoke Detector Before Installing ULC standard CAN/ULC-S524-M91 Standard For The Installation Of Fire Alarm Systems should be referenced for

More information

D2E Duct Smoke Detector

D2E Duct Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS D2E Duct Smoke Detector Specifications Operating Temperature: 20 to 60 C Storage Temperature: 20 to 60 C Humidity: 0% to 93% Relative Humidity Non-condensing Air

More information

Addendum for STI-6406 with Dual Access Control

Addendum for STI-6406 with Dual Access Control Addendum for STI-6406 with Dual Access Control Description: This system contains a STI-6400 with a DPDT key switch to be mounted on one side of a door or wall; and a similar looking housing, also with

More information

T874 Multistage Thermostat and Q674 Subbase

T874 Multistage Thermostat and Q674 Subbase SUPER TRADELINE T874 Multistage Thermostat and Q674 Subbase Application The T874D Thermostat and Q674E Subbase provide 4 to 30 Vac control of standard stage heating and stage cooling systems. The Y594D

More information

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F II 1400-2 ACSI 1406-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F INSTALLATION Transformer Model BE31763001 by Basler Electric, Transformer Model 2010028 by Galaxy

More information

INSTALLATION & MAINTENANCE CORNELL FIREGARD CHAIN & ES ECO #1515 REVISION # 0000 FIREGARD CRANK OPERATORS BY: RICKM DATE: 3/23/2011

INSTALLATION & MAINTENANCE CORNELL FIREGARD CHAIN & ES ECO #1515 REVISION # 0000 FIREGARD CRANK OPERATORS BY: RICKM DATE: 3/23/2011 INSTALLATION & MAINTENANCE CORNELL FIREGARD CHAIN & ES 10-343 ECO #1515 REVISION # 0000 FIREGARD CRANK OPERATORS BY: RICKM DATE: 3/23/2011 INSTRUCTION MANUAL FireGard Chain Operator (Model FCF) & FireGard

More information

Installation Instructions for W2H Series Signals

Installation Instructions for W2H Series Signals Installation Instructions for W2H Series Signals IF1513 A Description and Operation DIMENSIONS W2H A 8 7/8" (225 mm) B 8 1/4" (210 mm) C 13" (330 mm) Figure 1. Speaker/Amplifier Dimensions The W2H signaling

More information

D285DH. Installation Instructions Photoelectric Duct Smoke Detector

D285DH. Installation Instructions Photoelectric Duct Smoke Detector D85DH EN Installation Instructions Photoelectric Duct Smoke Detector D85DH Installation Instructions.0 Introduction FCC Notice The D85DH Photoelectric Duct Smoke Detector complies with Part 5 of the Federal

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-(845-4641) or visit the Viking Web site at vikingrange.com

More information

MODEL B2 INSTALLATION MANUAL

MODEL B2 INSTALLATION MANUAL RELEASE DEVICES GENERAL DESCRIPTION MODEL B2 INSTALLATION MANUAL S/N: The B2 Series Time Delay Release Devices are UL Listed, Canadian Listed, and CSFM Listed for use on rolling doors, single-slide and

More information

Installation Guide. 15 W./24 W. Undercounter Refrigeration

Installation Guide. 15 W./24 W. Undercounter Refrigeration Installation Guide 15 W./24 W. Undercounter Refrigeration Table of Contents Warnings & Important Information 3 Proper Disposal 4 Dimensions (15 W. Professional) 5 Dimensions (24 W. Professional) 6 Dimensions

More information

AUTO RESET ALARM RELEASE BOX MODEL AR-C INSTRUCTION MANUAL

AUTO RESET ALARM RELEASE BOX MODEL AR-C INSTRUCTION MANUAL AUTO RESET ALARM RELEASE BOX MODEL AR-C INSTRUCTION MANUAL AR C Rev.06 WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual prior to

More information

Installation Instructions

Installation Instructions Dear customer! Thank you for choosing this quality product from ASKO. We hope it will meet your expectations and fulfil your needs for many years to come. Scandinavian design combines clean lines, everyday

More information

Integrated Refrigeration

Integrated Refrigeration INSTALLATION GUIDE Integrated Refrigeration Contents Integrated Refrigeration....................... 3 Model Specifications.......................... 4 Site Preparation.............................. 6

More information

EcoVision Door Manual

EcoVision Door Manual EcoVision Door Manual for Reach-In (RMTD) Merchandisers Installation & Operation Manual Shipped With Case Data Sheets IMPORTANT Keep in store for future reference! MANUAL- I/O ECOVISION REACH-IN DOORS

More information

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL MADE IN THE U.S.A. U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION SERIAL NUMBER The Cookson Company FIREFLY II PLUS Time Delay Release

More information

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE COVE DISHWASHER Contents 3 Cove Dishwasher 4 Specifications 7 Door Panel 9 Installation 15 Troubleshooting Features and specifications

More information

Exit Stopper. STI-6400 Series

Exit Stopper. STI-6400 Series Exit Stopper STI-6400 Series Features Alarm helps prevent unauthorized exits/entries through doors. Easy to install. Select volume, duration and immediate or 15 second delay for arming and trip. May be

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide IMPORTANT Please Read and Follow! Please read all instructions thoroughly before installing the Convection Microwave Hood. Two people are recommended to install this product.

More information

Installation Instructions

Installation Instructions Instructions For Fully Integrated NoFrost Combined Refrigerator-Freezers HC 1540/1541 7084 433-00 Important Please read and follow these instructions These instructions contain Danger, Warning and Caution

More information

RELEASE DEVICE CONTROLS

RELEASE DEVICE CONTROLS RELEASE DEVICE CONTROLS RELEASE DEVICE MODEL C+ INSTALLATION MANUAL UL LISTED CANADIAN LISTED CSFM: 7300-48:00 GENERAL DESCRIPTION: MADE IN THE U.S.A. S/N: The LM0-C+ Release Device/Control Panel is a

More information

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

CM-RQE70A PIR REQUEST TO EXIT DETECTOR Door Activation Devices CM-RQE70A PIR REQUEST TO EXIT DETECTOR THIS PACKAGE INCLUDES (2) #6 x 3/4" Screws (2) 3/16" Wall Plugs (2) MOV's BP7175 1. GENERAL DESCRIPTION Camden CM-RQE70A Request-to-Exit Sensor

More information

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

CM-RQE70 PIR REQUEST TO EXIT DETECTOR Door Activation Devices CM-RQE70 PIR REQUEST TO EXIT DETECTOR THIS PACKAGE INCLUDES (1) Wiring Harness (2) #6 x 3/4" Screws (2) 3/16" Wall Plugs (6) Wire Nuts (2) 's BP7175 1. GENERAL DESCRIPTION Camden

More information

TS 93. Cam action door closer system in Contur Design

TS 93. Cam action door closer system in Contur Design TS 9 Cam action door closer system in Contur Design VERSATILE AND ELEGANT The TS 9 cam action door closer system provides a high-quality architectural solution for all project application requirements.

More information

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions 1 PACKAGE CONTENTS Wiring Harness 6 Wire Nuts #6 x 3/4 Screws s BP7175 3/16 Wall Plugs Section 1: General Description Camden CM-RQE-70 Request-to-Exit

More information

Installation Guide. 15 W./24 W. Undercounter Refrigeration U L. Viking Range Corporation. 111 Front Street. Greenwood, Mississippi USA

Installation Guide. 15 W./24 W. Undercounter Refrigeration U L. Viking Range Corporation. 111 Front Street. Greenwood, Mississippi USA Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-845-4641 U L C U L 15 W./24 W. Undercounter Refrigeration

More information

Model PF 2030 Wide Area Vacuum Cleaner

Model PF 2030 Wide Area Vacuum Cleaner Model PF 2030 Wide Area Vacuum Cleaner OPERATING INSTRUCTIONS COMMERCIAL WIDE AREA SWEEPER VACUUM CONGRATULATIONS YOU HAVE JUST ACQUIRED A HIGH QUALITY VACUUM CLEANER. PLEASE READ THIS MANUAL CAREFULLY,

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual NFJGCX, NCJGCX, NTJGCX, NFMJGCX, NFJGECX, NCJGECX GLASS FRONT JUMBO ISLAND FROZEN FOOD/ICE CREAM/ MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display

More information

Installation Guide for models:

Installation Guide for models: 140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal3FD - 12VDC @ 4.6 amp or 24VDC @ 5.2 amp. - Sixteen (16) PTC protected power-limited outputs.

More information

Cam action door closer system DORMA TS 93

Cam action door closer system DORMA TS 93 Cam action door closer system DORMA TS 93 reddot design award winner 200 DORMA TS 93 Cam action door closer system DORMA TS 93 Cam action door closer system TS 93 G-SR-EMR Versatile and elegant The TS

More information

Exit Stopper. STI-6400 Series

Exit Stopper. STI-6400 Series Exit Stopper STI-6400 Series Features Alarm helps prevent unauthorized exits/entries through doors. Easy to install. Select volume, alarm duration and delay settings. May be mounted on top, right, left

More information

DETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS

DETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS TEST LOG Detector Identification Information Manufacturer and Serial Date Detector Model: Number: Installed: Description of Detector Location: Test Results and Maintenance Data Date Test Test Maintenance

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL CEILING FAN OWNER'S MANUAL MODEL: Pelham HVFC# 2299 Old Bronze Satin Nickel Polished Nickel READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz. CUL LISTED MODEL: AC-554SY05-7S WEIGHT OF THE FAN:

More information

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM TTC-1 TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION The nvent RAYCHEM TraceTek TTC-1 sensing module is used with TraceTek sensing cables to detect liquid leaks.

More information

Installation Instructions for Med-Touch Series LCD Medical Gas Area, Master & Combination Alarms Conversion Kits

Installation Instructions for Med-Touch Series LCD Medical Gas Area, Master & Combination Alarms Conversion Kits Manufacturer of Medical Gas Pipeline Equipment Installation Instructions for Med-Touch Series LCD Medical Gas Area, Master & Combination Alarms Conversion Kits Master Alarm Conversion Combination Alarm

More information

Installation Instructions

Installation Instructions Installation Instructions For Fully Integrated NoFrost Combined Refrigerator-Freezers HCB 1560/1561 7084 429-00 Important Please read and follow these instructions These instructions contain Danger, Warning

More information

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC. M Series Multi-Output Access Control Power Supply Chargers Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 3 amp @ 12VDC or 4 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp

More information

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS Specifications subject to change without notice. USA 150303 Page 1 of 10 MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS Specifications subject to change without notice.

More information

Undercounter Refrigeration

Undercounter Refrigeration INSTALLATION GUIDE Undercounter Refrigeration Contents Undercounter Refrigeration..................... 3 Undercounter Specifications.................... 4 Site Preparation..............................

More information

KIT IOM

KIT IOM 8733 800-259 KIT IOM Replacement Kit: 641-176 641-187 641-225 641-244 1 Table of Contents THE UPM CONTROLLER...3 SPECIFICATIONS...4 KIT INCLUDES...5 INSTALLATION PROCEDURE...5 Remove Old Board...5 Mounting

More information

The feedhorn heaters consist of heater wire attached to a strap and covered with heatshrink. They are attached to a rib on the feedhorn.

The feedhorn heaters consist of heater wire attached to a strap and covered with heatshrink. They are attached to a rib on the feedhorn. Satellite Antenna De-icing Systems Automatic De-icing System for Protection against Snow and Ice Simple to Field Install and Operate Engineered for Customer Specified Voltages Low Energy Costs User selectable

More information

01_TT_TST_04_61_GB.qxd :30 Uhr Seite 4. Door Closers and Door Control Systems

01_TT_TST_04_61_GB.qxd :30 Uhr Seite 4. Door Closers and Door Control Systems 0_TT_TST_04_6_GB.qxd 5.08.004 9:0 Uhr Seite 4 Door Closers and Door Control Systems 4 0_TT_TST_04_6_GB.qxd 5.08.004 9:0 Uhr Seite 5 4 6 Concealed cam action door closers with slide channel Cam action and

More information

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

TRUERH Series HE-67xx Humidity Element with Temperature Sensor Installation Instructions HE-67xx Issue Date 0501 TRUERH Series HE-67xx Humidity Element with Temperature Sensor Installation IMPORTANT: The HE-67xx Series Humidity Element with Temperature Sensor is designed

More information

D343. Installation Instructions. Air Duct Smoke Housing

D343. Installation Instructions. Air Duct Smoke Housing D E Installation Instructions Air Duct Smoke Housing D Installation Instructions.0 Overview. Trademarks ational Fire Alarm Code is a trademark of the ational Fire Protection Association, Inc. ife Safety

More information

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

THE SS90 SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL S S S S S S S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED U 99Y9 RESET L RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

Microwave/PIR Intrusion Detector with POPIT Interface ZX970 Microwave/PIR Intrusion Detector with POPIT Interface ZX970 Installation Instructions 1.0 Specifications Input Power: 9 to 15 VDC, 6 ma nominal (35 ma with LED on) Zonex Current Draw: 500 ma Standby Power:

More information

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev RPSMLR2 RPSMLR2BB Panic Device Power Controller Installation Guide LISTED Rev. 102715 Overview: RPSMLR2BB, RPSMLR2 will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed

More information

Service Manual Trash Compactor Models 15XESSEXF A November 2010 Broan-NuTone LLC 926 West State Street Hartford, WI

Service Manual Trash Compactor Models 15XESSEXF A November 2010 Broan-NuTone LLC 926 West State Street Hartford, WI Service Manual Trash Compactor Models 15XESSEXF 99044663A November 2010 Broan-NuTone LLC 926 West State Street Hartford, WI 53027 1-800-637-1453 2 Safe Servicing Practices Safe Servicing Practices To avoid

More information

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase M3375 M3375 T890A/908AJ Heating or Cooling Thermostat/Wallplate; T890A/Q68B Heating/Cooling Thermostat/Subbase Installation Instructions for the Trained Service Technician. Preparation NOTE: Order Q68B

More information

CEILING SPEAKER SYSTEM

CEILING SPEAKER SYSTEM Rev. A INSTRUCTION MANUAL CEILING SPEAKER SYSTEM F-122CU2 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for

More information

Installation and Use Manual

Installation and Use Manual Installation and Use Manual EMABFWS-RF and LMABFWS-RF Retrofit Bottle Filling Stations IMPORTANT THIS IS AN INDOOR APPLICATION ONLY. ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON. TOOLS REQUIRED

More information

Installer Guide. WARNING Important Safety Information. 1 Specifications

Installer Guide. WARNING Important Safety Information. 1 Specifications 1 Specifications cont. Premier Series Universal Auto Changeover Up to 3 Heat / 2 Cool Conventional and Heat Pump Thermostat Installer Guide Before Installing, Programming or Operating, PLEASE READ ALL

More information

L62GB BASO Safety Shutoff Device

L62GB BASO Safety Shutoff Device Installation Instructions Issue Date August 18, 2008 L62GB BASO Safety Shutoff Device Installation IMPORTANT: Only qualified personnel should install or service BASO Gas Products. These instructions are

More information

TYPE C: RETURN AIR UNDER POSITIVE PRESSURE FROM SEPARATE BLOWER

TYPE C: RETURN AIR UNDER POSITIVE PRESSURE FROM SEPARATE BLOWER Installation Instructions Model AD-HR Air Duct Monitoring Housing INTRODUCTION The SIEMENS Model AD-HR is a sampling tube, air duct monitoring housing. When used with a compatible smoke detector, smoke

More information