SISTEMAS DE SEGURIDAD MIRA, S.L. COMPANY & PRODUCT GUIDE

Size: px
Start display at page:

Download "SISTEMAS DE SEGURIDAD MIRA, S.L. COMPANY & PRODUCT GUIDE"

Transcription

1 SISTEMAS DE SEGURIDAD MIRA, S.L. COMPANY & PRODUCT GUIDE

2 Sistemas de Seguridad Mira, S.L. focuses on the design, development and manufacture of advanced components for fire detection systems. To secure this end, our team that has over 25 years experience, is highly motivated to offer leading-edge products to our customers.

3 OUR PHILOSOPHY... Aware of the importance of choosing a good equipment, we want to offer installers a reputable product in daily practice, with the best quality - price rate we can offer. So, focusing our efforts on the design and manufacture, we leave other superfluous matters to be resolved with austerity, allowing installation professionals and distributors that give products a larger presence in the market for being: Competent and Competitive

4 PRODUCT LINES CONVENTIONAL FIRE DETECTION Micro processed conventional c. panels Conventional fire detectors Sounders and Ancillary CARBON MONOXIDE DETECTION Electrochemical cell detection system POWER SUPPLIES 12V & 24V Power supplies

5 CONVENTIONAL CONTROL PANELS M400 SERIES The M400 fire panels had been designed meeting EN 54-2&4 as a control unit for fire detection systems in small and medium sized buildings Robust and reliable, its features allow fast, efficient installation and maintenance, simple operation and an attractive housing

6 M402C & M404CP CONTROL PANELS (DIMENSIONS 281 X 231 X 98 mm) Conventional fire detection control panel, available in 2 and 4 zones Microprocessor controlled Easy access code for keypad activation Programmable sounders delay Day/Night status facility One man test facility Zones isolation possibility General alarm press button for evacuation function Automatic led test Specified indication for detector's fire alarm or manual call alarm Specified indication of fire zones or sounders line faults Specified indication of mains power, battery charge or system fault 2 supervised sounders output 2 voltage free relays for fire and fault Auxiliary 24V ma output for external devices ABS thermoplastic front cover with 1 mm galvanized steel back plate Full EN-54 2/4 certificated

7 M404CG, M408C & M412C CONTROL PANELS (DIMENSIONS 339 X 332 X 90 MM) Conventional fire detection control panel, available in 4, 8 and 12 zones Microprocessor controlled Easy access code for keypad activation Programmable sounders delay Day / Night status facility One man test facility Zones isolation possibility General alarm press button for evacuation function Automatic led test Specified indication for detector's fire alarm or manual call alarm Specified indication of fire zones or sounder line faults Specified indication of mains power, battery charge or system fault 2 supervised sounders output 2 voltage free relays for fire and fault Auxiliary 24V ma output for external devices ABS thermoplastic front cover with 1 mm galvanized steel back plate Full EN 54-4/2 ccertificated

8 TECHNICAL SPECIFICATION M400 CONTROL PANELS Mains supply voltage: 230 Vac 50 Hz (+-10%) Average quiescent current: 120 Zones voltage: 24Vdc Sounders alarm output: 24V 320mA (both) Auxiliary output: 24Vdc 320 ma EOL zones supervision: 4K7 resistance EOL sounders supervision: 4k7 resistance Alarm relay: NO/NA 2A-30Vdc Fault relay: NO/NA 2A-30Vdc Sounders output delay: potentiometer 0-10' Fuses: Mains, battery, aux, and sounders Battery capacity: 2 x 12v 2A or 7A IP protection rating: IP43

9 AUX. RELAY MODULE M400MR FOR M404CG, M408C, M412C The M400MR auxiliary relay module is connected to the main panel s PCB, giving 4 independent relay outputs for each 4 zones group. ZONAS 1,2,3,4 CONECTOR TECLADO CN AN C CN A N C CN A N C CN A N C ZONAS 1,2,3,4 ZONAS 5,6,7,8 CONECTOR TECLADO ZONAS 1,2,3,4 ZONAS 5,6,7,8 ZONAS 9,10,11,12 CONECTOR TECLADO CABLE ROJO CABLE ROJO CA BLE A ZUL CABLE NEGRO CABLE AZUL CABLE NEGRO

10 EXTINGUISHANT CONTROL PANEL M401-EXT 2 ZONES CONTROL PANEL FOR 1 EXTINGHISHANT SYSTEM STAGE FEATURES Easy extinguishant release delay configuration by potentiometer. Integrated abort switch in the panel keypad. Specific manual release and abort input circuits for external operation Led indicators for pre-release/release/pre-release abort 4 relay outputs for: solenoid, door close, pre-release and release annunciators 4 contact inputs for de pressure switch, extinguishiant released, etc Adjustable Sounders delay. Zones disablement facility. Optional external modem ( SMS alarm / fault messages). Optional timer for event log registry. Designed and manufactured to comply with EN

11 EXTINGUISHANT CONTROL PANEL M404-EXT 4 ZONES CONTROL PANEL FOR 2 EXTINGHISHANT SYSTEM STAGES. FEATURES Easy extinguishant release delay configuration by potentiometer. Integrated abort switch in the panel keypad. Specific manual release and abort input circuits for external operation Led indicators for pre-release/release/pre-release abort 8 relay outputs for: solenoid, door close, pre-release and release annunciators 8 contact inputs for de pressure switch, extinguishant released, etc Adjustable Sounders delay. Zones disblement facility. Optional external modem ( SMS alarm / fault messages). Optional timer for event log registry. Designed and manufactured to comply with EN

12 OPTICAL SMOKE DETECTOR M500C Optical smoke detector EN54-7 certified, low consumption and advanced designed with selfchecking function, automatic drift compensation and maintenance alert for contaminated chamber status, suitable for general applications.

13 M500 OPTICAL SMOKE DETECTOR FEATURES Photo-electric micro processed optical smoke detector EN 54-7 certified Low profile and surface mounting bases with 4 x 20 mm knockouts Independent and easy to plug detector head unauthorized removal protection Nickel-plated bronze double clip terminals for double faced connections SMD electric circuit fully encapsulated for protection. Approved components Wide voltage supply range: Vcc. Very low current requirement 360º visible alarm led and remote indicator connection Flashing led for normal status confirmation Automatic drift compensation. Maintenance alert for chamber contamination status ABS thermoplastic. White external enclosure with installation dust cover Approval certification by Applus Dimensions: 100 x 36 mm ( diameter x height)

14 M500 OPTICAL SMOKE DETECTOR TECHNICAL SPECIFICATION Supply voltage: 11V a 35 Vcc Average quiescent current : 24V Alarm 24V: Remote output: 100 ma Normal operating temperature: -10ºC a 60ºC Max. operating humidity: 90% w/o condensation

15 M501C/PK HEAT DETECTOR Static and rate-of-rise detector with very low current consumption and simple installation. EN54-5 certified for dusty and difficult environment applications

16 M501C/PK HEAT DETECTOR FEATURES Rate of rise heat detector with static upper limit at 57ºC, EN 54-5 certified Low profile and surface mounting bases with 4 x 20 mm knockouts Independent easy to plug detector head with unauthorised removal protection Nickel-plated bronze double clip terminals for double faced connections SMD electric circuit fully encapsulate for protection. Approved components Wide voltage supply range: Vcc. Very low current requirement 360º visible alarm led and remote indicator connection White ABS thermoplastic enclosure with installation dust cover. Approval certification by Applus Dimensions: 100 x 36 mm ( diameter x height)

17 M501C/PK HEAT DETECTOR TECHNICAL SPECIFICATION Supply voltage: Average quiescent current : Alarm 24 V: Remote output: Normal operating temperature: Maximum operating humidity: Vcc ma 100 ma maximum -10ºC to 60ºC 95% without condensation

18 M502C MULTISENSOR DETECTOR Multisensor smoke and heat detector, EN54-5/7 certified with enhanced detection capability for both fast high energy burning and slow smouldering fires.

19 M502C MULTISENSOR DETECTOR FEATURES Optical (smoke) & heat (rate of rise) multisensor detector EN 54-7 certified Low profile and surface mounting bases with 4 x 20 mm knockouts Independent easy to plug detector head with unauthorized removal protection Nickel-plated (phosphorous) bronze clip terminals for double faced connections SMD electric circuit fully encapsulated for protection. Approved components Wide voltage supply range: Vcc. Very low current requirement 360º visible alarm led and remote indicator connection Flashing led for normal status confirmation Automatic drift compensation Maintenance alert for chamber contamination status ABS thermoplastic. White external enclosure with installation dust cover. Approval certification by Applus. Dimensions: 100 x 36 mm ( diameter x height)

20 M502C MULTISENSOR OPTICAL /HEAT DETECTOR TECHNICAL SPECIFICATION Supply voltage: Average quiescent current : Alarm 24V: Remote output: Normal operating temperature: Max. operating temperature: 11V a 35 Vcc 40uA... 24V 100 ma -10ºC a 60ºC -15ºC a 80ºC 90% w/o condensation

21 M500Z MOUNTING BASES The range of M500Z bases allows a simple installation of all MIRA M500 detectors giving more space for wiring connexion. Nickel-plated (phosphorous) bronze double clip terminals for double faced connections make an optimal and reliable contact with the easy to plug detector head, with unauthorized removal protection. M500Z- LOW PROFILE BASE 4+1 TERMINALS: Low profile base with detection line and remote led terminals, for general purpose applications. The base offers a terminal for screens connection. Dimensions: 100 x 8 mm (d x h) M500ZA- HIGH PROFILE BASE 4+1 CONTACTS: High profile base with detection line, remote led and screen terminals for surface mounting with 4 x 20 mm knockouts. Dimensions: 100 x 28 mm (d x h) M500ZR- HIGH PROFILE BASE WITH RELAY OUTPUT: High profile base provides changeover volt-free contacts for special applications like burglar and domotic systems, etc. 12Vcc power supply. Dimensions: 100 x 28 mm (d x h)

22 ADJUSTABLE HEAT PROBE ºC M105 Control unit with regulation device in a metal box and heat measurement thermostatic probe, for special applications. Heat measurement range : ºC Dimensions: 115 x 115 x 50 mm Terminals: Voltage free changeover relay 2,5A / 250V

23 M100FI CONVENTIONAL FIRE SOUNDER & FLASH The M100FI fire sounder and LED flash has been designed to meet the EN standard as an audible and visual fire signal for indoor use. It offers a high power sound output with a minimum current drain (12 ma), in a sturdy and discreet aesthetics casing, particularly well suited for use in a wide range of applications.

24 M100FI CONVENTIONAL FIRE SOUNDER & FLASH FEATURES Acoustic and visual fire alarm EN certificated Selectable as sound and light or only light alarm signal ( high output LED) Easy surface mounting with 1 x 20 mm knockout. SMD electric circuit. Approved components Wide voltage supply range : 15 a 30 Vcc. Reverse polarity protected Very low current requirement : maximum 24 V ( sound and light) Sound output ( 1 meter): 95 24V / CEI 60651: selectable tones for sound signals with internal switch Ingress protection: IP 53C / EN 60529:1991 Thermoplastic ABS, red RAL 3000 colour Dimensions 100 x 35 mm ( d x h )

25 M100FI CONVENTIONAL FIRE SOUNDER & FLASH TECHNICAL SPECIFICATION Supply voltage: Current SL (sound & light): 12 24V Current L (light only) 6 24V 15Vcc a 30Vcc Sound output (1 m): 95 24V / CEI 60651: Ingress protection: IP 53C / EN Output frequency (CN4 switch): Short or long cycle Normal operating temperature: -10ºC a 70ºC (SL)+2 4 V Maximum operating humidity: 95% w/o condensation NO (L) 0V (-) US E Tone selection (CN4) +24V

26 M103 ILLUMINATED ANNUNCIATOR Illuminated security annunciator with optical and acoustic signalling with 3 different messages: M103ED : EXTINGUISHANT RELEASED M103GT: TOXIC GAS M103FG: FIRE TECHNICAL SPECIFICATION Supply voltage : 24 Vcc Average quiescent 24V: 200 ma Buzzer output: 80 db IP rating: IP45 Normal operating temperature: ºC Dimensions: 234 x 117 x 59 mm

27 CARBON MONOXIDE DETECTION ELECTROCHEMICAL SENSOR BASED CERCO 300 EQ CO DETECTION SYSTEM

28 CERCO 300 EQ ADVANTAGES... 1) Only 2 x 1,5 mm2 non-polarized connection line, free installation architecture. 2) Advanced detectors to panel data transmission system for enhanced distances. 3) Up to 16 detectors per zone s module, with address and detection level on display Del Transfor mador R el é T u r b o R el é E xt ra ct o r R el é A la r m a A otros módul os M as det ect or es Mas detectores

29 4) Three different programmable level outputs for each module to operate three different alarm / ventilation systems. 5) Programmable ventilation delay for energy saving A la línea eléctrica A los sensores A los sensores (ZONA 2) (ZONA 1) Conexión entre módulos A la línea eléctrica Extra ctor Extra ctor (Tur Sistema bo) acústico y/o luminoso Sistema acústico y/o luminoso Red eléctrica Fusi ble Transformador toroidal

30 6) The gas is detected using electrochemical sensors, so the result is a reliable long life device with high sensitivity, fast detection and maximum selectivity with no humidity, temperature or other gases interferences. Gas e - OH, HCO 3, CO 2 3 A Aire

31 CERCO 300 EQ SYSTEM ME302 CONTROL PANEL FEATURES CO detection control panels available in 1 or 2 zones models Maximum accuracy with ME300D electrochemical detectors Up to 16 detectors per zone, fully identified ( Address, alarm or fault) 2 x 1,5 mm2 non-polarized detectors line, free installation architecture 3 different working modes: manual, automatic or only alarm 3 different programmable level outputs: working ventilation, turbo ventilation and alarm Programmable ventilation delay for energy saving One detector readings interval: 25 secs. Flashing led signalling Up to 350 mts. distance to last detector. ( Easily improved with better wire specification) 3 digits display, 10 leds and 4 press buttons for simple use and programming IP 35 grey painted steel enclosure 195 x 195 x 80 mm LOM certified UNE standard CO and NO2 detectors can be integrated to the system

32 CERCO 300 EQ SYSTEM ME305 CONTROL PANEL FEATURES CO detection control panels available in 3,4 & 5 zones models Maximum accuracy with ME300D electrochemical detectors Up to 16 detectors per zone, fully identified ( Address, alarm or fault) 2 x 1,5 mm2 non-polarized detectors line, free installation architecture 3 different working modes: manual, automatic or only alarm 3 different programmable level outputs: working ventilation, turbo ventilation and alarm Programmable ventilation delay for energy saving One detector readings interval: 25 secs. Flashing led signalling Up to 350 mts. distance to last detector. ( Easily improved with better wire specification) 3 digits display, 10 leds and 4 press buttons for simple use and programming IP 35 grey painted steel enclosure 195 x 455 x 80 mm LOM certified UNE standard CO and NO2 detectors can be integrated to the system

33 CERCO 300 EQ SYSTEM ME300D ELECTROCHEMICAL SENSORS FEATURES Maximum accuracy electro-chemical Carbon Monoxide (CO) detector Surface mounting high profile bases with 4 x 20 mm knockouts Easy to plug independent detector head with unauthorized removal protection Nickel-plated bronze ( phosphorous) double clip terminals for double faced connections SMD electric circuit fully encapsulated for environment protection 360º visible alarm led and status confirmation 7 years expected operational life Typical instantaneous response time 60 secs. typical response time for 16 detectors 2 wire free-installation architecture without polarity ABS gray thermoplastic enclosure Dimensions: 100 x 55 mm ( diameter x height) Approved and LOM certified UNE standard

34 NITROGEN DIOXIDE MN300D ELECTROCHEMICAL SENSOR The new Nitrogen Dioxide (SO2) electrochemical detectors can be integrated in the same detection line with existing Carbon Monoxide (CO) detectors allowing the panel to be triggered at the programmed levels in any of both criteria with the corresponding level translation.

35 CO AND SO2 DETECTORS MAINTENANCE PROGRAM In order to keep the systems operating efficiently after the detector s expected life, we offer to the maintenance companies and distributors a comprehensive package, including routine service for detectors, repair facilities, etc

36 POWER SUPPLIES Commuted power supplies, specially designed for fire and security systems, in a robust and attractive steel casing with enough space for batteries, limited charging facility and short-circuit protected. FA24V 2,5A 12V 2A - 12V 3A Dimensions: 232 x 192 x 88 mm, suitable for 2 x 12V 2Ah batteries FA24V 5A 24V 7A 12V 7A Dimensions: 252 x 312 x 98 mm, suitable for 2 x 12V 7Ah batteries PD.:More interesting fire detection products coming soon...

37 THE END THANKS FOR YOUR ATTENTION

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum

More information

FEC400 Series. Installation Manual

FEC400 Series. Installation Manual FEC400 Series Conventional microprocessor controlled fire detection and alarm panels with extinguishing control Installation Manual Version 2.3 / August 2004 Aritech is a GE Interlogix brand. http://www.geindustrial.com/ge-interlogix/emea

More information

System 800 Addressable Fire Detection & Alarm System

System 800 Addressable Fire Detection & Alarm System SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools

More information

Excel-EN Conventional Fire Control Panel

Excel-EN Conventional Fire Control Panel Available as 2, 4, 6, 8,10 or 12 zones Approved to EN54-2 & 4 Modular expansion zone cards Programmable relays and outputs Optional additional sounder circuits Optional additional programmable outputs

More information

Conventional Fire Detection

Conventional Fire Detection SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct

More information

OPERATION AND INSTALLATION MANUAL

OPERATION AND INSTALLATION MANUAL EX+Plus 2 ZONE, 1AREA EXTINGUISHANT CONTROL PANEL OPERATION AND INSTALLATION MANUAL INTRODUCTION The Premier EX Plus is a 2 zone, single area panel for controlling the release of extinguishing gases in

More information

Application, Installation, Operation & Maintenance Manual

Application, Installation, Operation & Maintenance Manual APPROVED BY:JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL Application, Installation, Operation & Maintenance Manual PAGE 1 of 43 CONTENTS 1. INTRODUCTION... 3 2. GENERAL DESCRIPTION...

More information

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009 Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual Man-1048 Issue 05 October 2009 CONTENTS Contents... Page Safety & Installation...2 Installation - continued...3

More information

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL 26 Aug 2015 V1.8 Page 1 SECTION CONTENTS PAGE NO. 1.0 SYSTEMS DESCRIPTION 1.1 General descriptions 2 1.2 Master Alarm PCB 2 1.3 Zone Display Board 2 1.4

More information

Xenex Conventional Fire Detection & Alarm System

Xenex Conventional Fire Detection & Alarm System SECTI 4: page 1 Section 4: Xenex Conventional Fire Detection & Alarm System SECTI 4: page 3 Xenex system architecture Beam Transmitter Beam Receiver End of Line Call Point Smoke Detector Smoke Detector

More information

intelligent solutions

intelligent solutions Alco is one of the leading intelligent solution providers of Fire Detection System. Security System and Public Addressing System in the United States of America. Based in California since 1992, we have

More information

Conventional Releasing Control Panel

Conventional Releasing Control Panel s Data Sheet Fire Safety Products Conventional Releasing Control Panel Pre-Action Deluge Agent-Releasing Fire System Model TXR-320 Remote configurable Up to two (2) hazard areas Operable with the following:

More information

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control File: S8485 Wiring Diagram This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control Panel. The operation of this product is intended for indoor

More information

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices. FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001

More information

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

FIREBETA EXTINGUISHING CONTROL PANEL (ECP) F I R E D E T E C T I O N A N D C O N T R O L FIREBETA EXTINGUISHING CONTROL PANEL (ECP) Three versions: 2 areas of detection and 1 area extinguishing 4 areas of detection and 1 area extinguishing 4 areas

More information

Industries. As a premier global manufacturing company, we believe that great brands are

Industries. As a premier global manufacturing company, we believe that great brands are JSB Fire Systems ONE COOPER Every day, thousands of people all over the world use products made by Cooper Industries. As a premier global manufacturing company, we believe that great brands are built on

More information

SALES SUPPORT DOCUMENT

SALES SUPPORT DOCUMENT SALES SUPPORT DOCUMENT ML-322 MAXLOGIC CONVENTIONAL FIRE EXTINGUISHING CONTROL PANEL ML-322 series operates on cross-zone principle, has 4 detection zones and one extinguishing release output which is

More information

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops... GUIDE MANUAL INDEX 1- Introduction...5...5...6 4- The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops...7 4.2- The Control Panel 4 and 8 Loops...9 5- Installation Guide...10 5.1- Pre-Installation

More information

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels Installation and user manual for the FX range of fire panels 1, 2, 4 and 8 zone panels Contents Panel installation 3 Panel connections 3 Wiring connection drawings 4 Panel facilities 6 Installation check

More information

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System SYSTEM MANUAL FT1-SB Single Zone Fire Alarm System DOCUMENT HISTORY Issue Date Description Written By Checked By Draft 0 2/9/2008 Original Document. A. Shenouda C. Orr Issue 1 4/11/2011 Update drawing

More information

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS QUICK USER GUIDE FOR, 2 & 4 ZONE PANELS INDICATORS COLOUR INDICATION MON FAULT Yellow On when a fault condition has occurred, or if no other fault Led is on, this indicates 24v auxiliary fuse failure.

More information

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview Water Leak Detector - Four Zone with open/short-circuit detection Product overview The AX-WLDF is a four zone water leak detection module with open or short circuit sensor cable detection. The module must

More information

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS Fire Control Panel Installation & Programming Manual TBLE OF CONTENTS Page Getting Started 2 Power Supply Unit 3 Inputs 4 Outputs 4 LED Indications 4 User Keypad Functions 5 Engineer Keypad Functions 6

More information

VSN-RP1r Extinguishing Control Panel. User Manual (Software version 3.x) by Honeywell. doc. MIE-MN-570I rev.008

VSN-RP1r Extinguishing Control Panel. User Manual (Software version 3.x) by Honeywell.   doc. MIE-MN-570I rev.008 www.morley-ias.es by Honeywell VSN-RP1r Extinguishing Control Panel User Manual (Software version 3.x) doc. MIE-MN-570I rev.008 Information in this document is subject to change without notice. 22 June

More information

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays AEGIS Conventional Fire Alarm-Suppression Control Unit FEATURES Agency Approvals FM Approved FM Approved to ANSI/UL 864, 9th edition FM Approved to ULC-S527-99 Other domestic U.S. approvals/listings pending/

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV LC1 & 2 Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV ZIRCONLC1 One Zone Conventional Fire Panel ZIRCONLC2 Two Zone Conventional Fire Panel Compliant with EN54-2:1998 & EN54-4:1998

More information

FEC403EN Installation Manual

FEC403EN Installation Manual FEC403EN Installation Manual P/N 10-4101-501-2FC1-01 ISS 22JAN15 Copyright Trademarks and patents Manufacturer 2015 UTC Fire & Security. All rights reserved. The FEC403EN name and logo are trademarks of

More information

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3 INTELLIGENT FIRE TECHNOLOGY Twinflex and Multipoint V3 User Guide (TO BE RETAINED BY USER) 26-0340 Issue 3 Rafiki Protection Limited Rafiki policy is one of continual improvement and the right to change

More information

Precept Marine Control Panel Application Guide

Precept Marine Control Panel Application Guide Precept Marine Control Panel Application Guide Contents Page 1.0 Cabinet Specifications 2 2.0 Panel Hardware Specifications 5 3.0 Panel Configuration 8 4.0 Technical Specifications 8 5.0 Battery Sizes

More information

EFBW series - BiWire Ultra control panel

EFBW series - BiWire Ultra control panel 4.2 Control panels and repeater panels EFBW series - BiWire Ultra control panel Eaton s new BiWire Ultra fire detection system is unlike any other standard conventional system as the panel, conventional

More information

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2 Features Integrated (built-in NO2 sensor / detector (Electro chemical sensor type Measuring ranges 0-10 ppm, 0-20 ppm or 0-30 ppm LCD display to show actual in ppm Status LED indication Normal operation

More information

The EN54 Part 2 and 4 Fire System

The EN54 Part 2 and 4 Fire System Scope of work: To design, supply, install and commission a Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54 Part 2 and 4 Fire

More information

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4 PREMIER EX8 EXTINGUISHING PANEL USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN 12094 PART 1 & EN54 PARTS 2 & 4 USER MANUAL Approved Document No: GLT.MAN-132 INDEX Extinguishing

More information

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.

More information

RP1r-Supra / VSN-RP1r+ / ESS-RP1r-Supra Extinguishing Control Panel User Manual. HLSI-MN-103I v.06 September 2017

RP1r-Supra / VSN-RP1r+ / ESS-RP1r-Supra Extinguishing Control Panel User Manual. HLSI-MN-103I v.06 September 2017 / VSN-RP1r+ / ESS-RP1r-Supra Extinguishing Control Panel HLSI-MN-103I v.06 September 2017 Note Nota: This manual is valid for the following control panel models: RP1r-Supra VSN-RP1r+ (no touch screen)

More information

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL The LeakStopper Multizone detects the presence of water in environments where it is not supposed to be. Should water

More information

XC10 Extinguishing control panels

XC10 Extinguishing control panels XC10 Extinguishing control panels Market package 2.1 Advanced control panels for detection and alarming as well as for the activation of the extinguishing process Microprocessor-controlled fire detection

More information

Solution F2. Fire Alarm Control Panels one step ahead.

Solution F2. Fire Alarm Control Panels one step ahead. Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution

More information

RE 102 RE Fire Alarm Control Panel. Installation, Commissioning & Operating Manual

RE 102 RE Fire Alarm Control Panel. Installation, Commissioning & Operating Manual RE 102 RE - 104 Fire Alarm Control Panel Installation, Commissioning & Operating Manual 1 NOTES: 2 Table of Contents CHAPTER 1: Introduction......4 1.1: System Design & Planning...4 1.2: General....4 1.3:

More information

Fire Product Catalog

Fire Product Catalog Additional Expansion Modules Fire Product Catalog CLEVER FIRE SOLUTIONS MA 1000 / Analog Addressable Fire Alarm Panel 1 Military Industry Public Buildings Industrial & Commercial Company Profile We are

More information

LF-4000 Series Conventional Fire Alarm Control Unit

LF-4000 Series Conventional Fire Alarm Control Unit LF-4000 Series Conventional Fire Alarm Control Unit Features: 1 to 36 Zone Control Panels Control Key Switch Easy Push Button Control Switches Zone Circuit Monitoring for Open and Short Sounder Circuit

More information

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...

More information

Installation Manual Premier 412/816/832. Issue 10

Installation Manual Premier 412/816/832. Issue 10 Installation Manual Premier // Issue 0 Premier // Installation Manual 5. Operating the System Introduction Before attempting to operate the alarm system ensure you have familiarised yourself with all the

More information

Conventional Fire Alarm System 2014 V1.2

Conventional Fire Alarm System 2014 V1.2 Conventional Fire Alarm System 2014 V1.2 Product Overview Control Panel 2 Conventional Fire Panel GST102A 2 zone Fire panel GST104A 4 zone Fire panel GST108A 8 zone Fire panel GST116A 16 zone Fire Panel

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd OPERATIONAL NOTES FOR CONCEPT FIRE PANEL. NOTE ON NEW FIRE PANELS, POSITION 1 ON THE SIX WAY INTERNAL OPTION SWITCH IS TURNED ON, DISABLING THE ZONAL SOUNDERS. TO ENABLE ZONAL SOUNDERS TURN OFF. Operation

More information

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL 3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL USER MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273 Web:

More information

Conventional Leaflets

Conventional Leaflets Conventional Leaflets Panels Last updated October 1999 Make leaflet selection by clicking on appropriate bookmark Return to Menu Installation and Basic Commissioning guide for the range of 1,2,4 and 8

More information

MINERVA MX. 800 Series Ancillary Equipment

MINERVA MX. 800 Series Ancillary Equipment An extensive range of ancillary modules has been specifically designed for use with the MX range of Fire Controllers. The 800 range of ancillary modules provide the MX Fire Controller with a wide degree

More information

Multi-Gas-Controller MGC2

Multi-Gas-Controller MGC2 Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants

More information

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel Application Guide Contents Page 1.0 Introduction and Typical System Illustration 2 2.0 Cabinet Specifications 4 3.0 Hardware

More information

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 ANALOGUE FIRE DETECTION VIGILON COMPACT FEATURES & BENEFITS four Keep it Simple All Vigilon devices connect onto the same 2

More information

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module FIRE ALARM CONTROL EQUIPMENT Addendum October 2006 Instructions for new style EN54-4 Power supply unit module MXLK-05 Issue 2.0 June 2007 INSTALLATION Safety Suppliers of articles for use at work are required

More information

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual Syncro AS Analogue Addressable Fire Control Panel User Manual Man-1100 Issue 02 Nov. 2008 Index Section Page 1. Introduction...3 2. Safety...3 3. Panel Controls...4 3.1 Access Level 1...4 3.2 Access Level

More information

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide. Who we are? - Nº 1 Spanish fire alarm systems manufacturer. - 25 years experience in the fire detection field. - 40 countries worldwide. Own engineering, design and factories. Total control of production

More information

CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP

CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP FLx-LT-XP CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP Installation, Configuration and Operating Manual MAY 2008 MIE-MI-580I_FL rev.003 Information in this document is subject to change without notice.

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

USER MANUAL CEF AP28 CONTROL PANEL

USER MANUAL CEF AP28 CONTROL PANEL USER MANUAL CEF AP28 CONTROL PANEL AP28 WARNINGS This product has mains voltage present within the housing. Please take the necessary precautions in not allowing any liquid to spill on or into the housing.

More information

Control Panel Engineering and Commissioning Instructions

Control Panel Engineering and Commissioning Instructions Twinflex - V3 Fire Detection & Alarm System Control Panel Engineering and Commissioning Instructions (TO BE RETAINED BY THE COMMISSIONING ENGINEER) 26-0338 Issue 9 Fike s policy is one of continual improvement

More information

Carbon Monoxide (CO) detection system

Carbon Monoxide (CO) detection system 1973 Carbon Monoxide (CO) detection system CARB MOXIDE Presentation DESIGN GUIDE AND SELECTI OF CO SYSTEMS The basic purpose of a CO detection system, resides in ensuring a minimum conditions of sanitation

More information

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4 FIRE ALARM CONTROL PANEL INSTALLATION MANUAL Approved Document No. GLT -201-7-3 Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4 CONTENTS 1. INTRODUCTION... 1.1 HANDLING THE PCBS... 1.2 USING THIS MANUAL... 1.3

More information

The complete conventional fire warning system

The complete conventional fire warning system The complete conventional fire warning system www.espuk.com MAG2P 2 Zone Fire Panel 2 programmable zones Active end of line monitoring and head removal 30 fire detectors per zone Unlimited number of call

More information

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION... 2 2. STANDARD AND OPTIONAL PARTS LIST... 2 3. FEATURE DEFINITIONS... 3 4. TERMINAL DRAWING AND SPECIAL

More information

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel CVENTIAL ALARM S Features: Description: The LF-CP Series Fire Alarm Control Panel is manufactured based on advanced technology while maintaining high quality during assembly. It is of solid state circuitry

More information

GAS SUPRESSION CONTROL PANEL:

GAS SUPRESSION CONTROL PANEL: GAS SUPRESSION CONTROL PANEL: MODEL NAME: COMPANY: DELTA 437/2, Main Road, Mandwali Fazalpur, Delhi-110092 Page 1 ABOUT THE PRODUCT ASES is very proud of to introduce DELTA the completely digital microprocessor

More information

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL FIRE ALARM CONTROL PANEL COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL CONTENTS 1. INTRODUCTION. 3 1.1 HANDLING THE PCBS 1.2 USING THIS MANUAL

More information

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors Carbon Monoxide (CO) Detection PRODUCTS Accessories Conventional Detectors 2 Complete CO Detection The system-connected CO1224T and CO1224TR CO detectors with RealTest provide early warning by using reliable

More information

WARNING FIRE DOOR CLOSING

WARNING FIRE DOOR CLOSING PRODUCT INSTRUCTIS Stock Code: 088 FCP - Lite Floats Road, Wythenshawe Manchester, M 9WB Tel: + (0) 9 Fax: + (0) 9 Doc No PI - 88 Iss:.0 WARNING FIRE DOOR CLOSING STOP Contents ) Blank ) Features and

More information

4 wire conventional alarm system

4 wire conventional alarm system Scimitar 4 wire conventional alarm system from Channel Safety Systems Scimitar 4 wire conventional alarm system The Scimitar Fire Alarm Control System is a comprehensive range of high specification conventional

More information

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels CF5000, MF5000 and FXP5000 Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels 16 zone panels Contents PANEL INSTALLATION...3 Installation...3 PANEL WIRING... 3 Mains power

More information

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ELECTRONIC SOUNDER STROBE Model : AVD-C407 ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an

More information

Surveyor Envoy-MINI 4

Surveyor Envoy-MINI 4 Surveyor Envoy-MINI 4 CONTENTS SECTION 1 INTRODUCTION Page 4 About this manual Page 4 System design and planning Page 4 Panel types Page 4 General Page 4 SECTION 2 INSTALLATION Page 5 General Page 5 ESD

More information

Fire Alarm Control Panel. System Maintenance and Log Book

Fire Alarm Control Panel. System Maintenance and Log Book Fire Alarm Control Panel System Maintenance and Log Book Fire Alarm System Maintenance A fire alarm system must provide early and reliable warning of the outbreak of fire. To achieve this, the system remains

More information

Fire Alarm Control Panel Installation, Commissioning & Operation MAN

Fire Alarm Control Panel Installation, Commissioning & Operation MAN DH4 ZoneSense Fire Alarm Control Panel Installation, Commissioning & Operation MAN 1531-5 Access Level 1 (Normal Operation) Responding To An Alarm Zone FIRE Alarm Indicator - flashing Common FIRE Alarm

More information

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. TABLE OF CONTENTS... P.1 2. GENERAL DESCRIPTION... P.2... 3. STANDARD AND OPTIONAL PARTS LIST... P.2... 4. FEATURE

More information

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

ZIOU/230 - MAINS IO INSTRUCTION MANUAL Description ZIOU/230 - MAINS IO INSTRUCTION MANUAL The Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third party equipment with the Fire Alarm Control panel

More information

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Carbon Monoxide (CO) Gas Detector March 15 GCO 300 GCO Carbon Monoxide (CO) Gas Detector March 15 Features Output 4-20 ma or 2-10 Vdc Power supply 24 Vdc Ranges 0-100 ppm or 0-300 ppm IP65 enclosure with quick locking screws Digital measurement value processing

More information

TABLE OF CONTENTS TABLE OF CONTENTS 1

TABLE OF CONTENTS TABLE OF CONTENTS 1 TABLE OF CONTENTS TABLE OF CONTENTS 1 FEATURES 2 Keypad Programmable... 2 EEPROM Memory... 2 Static/Lightning Protection... 2 Supervision... 2 Operation... 2 SPECIFICATIONS 2 PC1550 Control Panel... 2

More information

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0) Overview of the Water Detection System 2 Components of a System 4 Design & Planning 5 System Installation Notes 7 Control Panel Installation - HSCPI-K3000 8 Control Panel Commissioning HSCPC-K3000 11 Front

More information

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi 50 (P/N 10-071) is a state-of-the-art true intelligent digital peer-to-peer modular suppression control system.

More information

5000 INSTALLATION GUIDE

5000 INSTALLATION GUIDE 5000 INSTALLATION GUIDE Table of Contents Section Page No 1. INTRODUCTION... 3 2. WARNINGS AND CAUTIONS... 3 3. UNPACKING... 3 4. INSTALLATION... 4 5. CONTROL PANEL - REMOVING ITEMS BEFORE MOUNTING...

More information

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output Features Electrochemical sensor element (0)2-10 Vdc or (0)4-20 ma output, jumper selectable Standard IP65 plastic enclosure Measuring ranges 0-50 ppm 0-100 ppm 0-150 ppm 0-200 ppm 0-250 ppm 0-300 ppm 0-500

More information

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi (P/N 10-068) is a state-of-the-art true intelligent digital peer-topeer modular suppression control system. It is ideal for

More information

LEAKSTOPPER RANGE Multizone water leak detection systems

LEAKSTOPPER RANGE Multizone water leak detection systems LEAKSTOPPER RANGE Multizone water leak detection systems WHAT DOES THE PRODUCT DO? The LeakStopper detects water leaks and instantly triggers an alarm to warn you. It is capable of monitoring between 2

More information

EX8. Instruction Manual: COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 AND EN54 PARTS 2 & 4

EX8. Instruction Manual: COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 AND EN54 PARTS 2 & 4 EX8 COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN 12094 PART 1 AND EN54 PARTS 2 & 4 Instruction Manual: Approved Document No: GLT.MAN-124 PAGE 2 INDEX INDEX... 3 Introduction... 4 Indications

More information

Vega Devices.

Vega Devices. Vega Devices This document lists the Argus Vega devices that are compatible with the Panels. It also highlights any specific requirements and technical information. Range of Fire Alarm Control The operation

More information

An introduction to... Sigma

An introduction to... Sigma An introduction to... Sigma XT+ Sigma XT+ Overview The Sigma XT+ 21000 series are the latest additions to the Sigma family of control equipment from Kentec Electronics Limited. The Sigma XT+ range combines

More information

Intelligent Single Loop Fire Alarm Control Panel

Intelligent Single Loop Fire Alarm Control Panel Intelligent Single Loop Fire Alarm Control Panel The CAX-CTL-1L Intelligent Single Loop Fire Alarm Control Panel is a member of the industry leading Axis AX Series Intelligent Fre Alarm Control Panels

More information

Installation Instructions 4 Zone Fire Panel

Installation Instructions 4 Zone Fire Panel Installation Instructions 4 Zone Fire Panel General Features Four fully controlled zones with test / disable capability per zone. Two full controlled alarm lines with disable capability per line. 4V/800mA

More information

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1 SmartTerminal AS7240 Installation and Operation Guide MAN2990-1 Table of Contents Page No. 1 Introduction... 3 2 Mechanical... 4 2.1 Mounting the Enclosure... 4 2.1.1 Enclosure Details... 4 2.1.2 Fixing

More information

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel Installation and Operating Manual HLSI-MN-025-I v.05 April 2015 Note: This manual is valid for the following control panel models: NFS-Supra

More information

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM Revision 2: November 1998 INDEX 1. SCOPE 2. GENERAL DESCRIPTION 3. STANDARDS 4. SYSTEM OPERATION 4.1 ACCESS LEVELS 4.2

More information

Emergi-Lite Orbis detectors

Emergi-Lite Orbis detectors Emergi-Lite Orbis detectors Emergi-Lite Orbis brings the latest in fire detector microprocessor technology to the Firetec and Eurofire systems. Non-addressable (conventional) smoke and heat sensors respond

More information

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit PRODUCT INSTRUCTIONS Fire Door Control Panel (FDCP) Floats Rd, Wythenshawe, Manchester. M23 9WB T: 44 (0)161 945 4561 F: 44 (0)161 945 4566 Stock Code Description Doc No: PI115 00133 00134 Ellard Fire

More information

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1 Matrix2000 User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 s Version: 2.0 Revision: 1 IMPORTANT INFORMATION Limitation of liability It is mandatory, Matrix2000 panel to be installed in accordance

More information

Addressable and Conventional Fire Protection

Addressable and Conventional Fire Protection Addressable and Conventional Fire Protection Simply reliable F I R E P R O T E C T I O N The MAGPro and Fireline systems has been created to balance performance, reliability and aesthetics whilst being

More information

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL 3500 CONVENTIONAL FIRE ALARM CONTROL PANEL USER MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273 Web:

More information

Touch Screen 1 loop Addressable Fire Alarm Panel

Touch Screen 1 loop Addressable Fire Alarm Panel evolution 1 Touch Screen 1 loop Addressable Fire Alarm Panel The evolution 1 control panel offers complete compatibility with the award winning range of Nittan evolution detection and alarm devices and

More information

The EN54 Part 2 & 4 Fire System

The EN54 Part 2 & 4 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information