M15-GSL12P30 M15-GSL12P30S Heat Spy Infrared Thermometer User Manual
|
|
- Rudolph Grant
- 6 years ago
- Views:
Transcription
1 M15-GSL12P30 M15-GSL12P30S Heat Spy Infrared Thermometer User Manual WD1097 Rev B 01/29/13 Wahl Instruments, Inc. 234 Old Weaverville Road Asheville, NC Toll Free Phone Fax
2 WARRANTY & CALIBRATION REGISTRATION at Registration is fast and easy. In about a minute you can have your product automatically registered for Warranty Protection and our Calibration Reminder service. Let Palmer Wahl help you protect your investment, and maintain product accuracy and compliance with ISO and other quality standards. Questions? Call Customer Service at or Or register@palmerwahl.com Important Information Read before using the Instrument! WARNING Laser Radiation is emitted from this device. Do Not stare into Laser Beam. Class 2 Laser, 650 nm, less than 10Hz 2
3 1. INTRODUCTION M15-GSL12P30 is designed for non-contact temperature measuring. It is Consists of a detector head, a control box and a signal cable. The detector head collects infrared energy from a target into an infrared sensor and converts this energy to an electrical signal. After processing, this signal is transmitted to the control box, which then displays a corresponding temperature. M15-GSL12P30S is the same sensor head used with the M15-03 above, but does not include the control box. It is intended for use with a 4-20mA output circuit or an RS485 digital communications port. FIXED INFRARED THERMOMETER set ZX SERIES esc ON OFF 2. SPECIFICATION Figure 1 Sensor with Control Box Measuring Range 0 to 1200 C / 0 to 2192 F Measuring Accuracy 1% of full measuring range Repeatability 0.3% of full measuring range Distance to Spot Ratio 30:1 Minimum Measuring Distance 0.5m Response Time 500 ms Sighting System Coaxial Laser Sighting Laser Specification 650nm, less than 10Hz Emissivity , adjustable Analog Output 4-20mA DC, 250Ωmax Power 100 to 240V AC, 50/60HZ Contact Capability of Relay 10A / 125V AC 7A / 250V AC 30V DC 3
4 Ambient Operating Temperature Control Box 0 to 50 C / 32 to 122 F Detector head 0 to 50 C / 32 to 122 F Main Functions High / Low Alarm Peak Temperature Display Over Range Indication 3. Operation Instructions for M15-GSL12P30 System HOW TO USE Install detector head Connect signal cable to the control box according to this instruction manual (Figure 3). Keep this cable away from AC wires Turn on the thermometer to start real time measuring, target temperature will be displayed. 3.1 Aiming: Press and hold the laser button on detector head for 2 seconds to select laser sighting while measuring. The laser will turn off automatically after 30 seconds. 3.2 Error Indication: Target temperature under -20 C (-4 F) LO appears Target temperature over 1200 C (2192 F), HI appears If working environment of detector head is less than 0 C (32 F) PLO appears If working environment of detector head is more than 50 C (122 F) PHI appears. 3.3 Control Box Operation: LED has 6 digits. The first bit indicates C/F, the second digit indicates status, and the last four digits indicate temperature Press and hold SET, the current functions step through in the following order: Emissivity: E and emissivity value will display, press or to adjust emissivity. 4
5 3.3.5 Identification Number of Detector Head:PP and identification number appear, press or to adjust the number. This is a unique user selectable identification number C/F: C and F appear at the first and second digit, the second digit indicates present status. F is Fahrenheit. C is Celsius. Press or to toggle between F and C, high/ low alarm and temperature reading will change accordingly High Alarm: FH/CH and high temperature limit appear, press or to adjust this value. If target temperature is above this limit, buzzer alarm will sound and FH/CH will display Low Alarm: FL/CL and low temperature limit appear, press or to adjust this value. If target temperature is under this limit, buzzer alarm will sound and FL/CL will display. Note: lowest temperature of low alarm: 0 C(32 F) Peak / Instantaneous Value: PH-- (instantaneous value) or PH00 (peak value) displays, press or to change between them To measure real time temperature, set the thermometer to instantaneous value. If it is set to peak value, PP and current peak temperature appear. This temperature will be updated by a new peak value Press ESC button to exit from any status and start temperature measuring Figure 2 Control Box Installations 5
6 CABLE CONNECTION A. Head and control box wiring. Red wire: DC12V, connect with Vcc of SIGNAL Black wire: GND, connect with of SIGNAL Note: the power is supplied by control box to detector head. Green wire: RS485A, connect with A(-) of RS485. Blue wire: RS485B, connect with B(-) of RS485. B. Yellow wire in detector head cable is 4-20mA (+), negative electrode of detector head power (Black Wire) is 4-20mA (-). C. 0-5V and 4-20mA on back panel of control box: Do not connect for this unit. D. AL1 includes two contacts for relay 1. It corresponds with the control of the high alarm. E. AL2 includes two contacts for relay 2. It corresponds with the control of the low alarm. Power When Temperature AL 1 Temperature Measured AL 2 Temperature Measured N/C-COM N/O-COM N/C-COM N/O-COM OFF Close Open Close Open ON Over high temperature limit Open Close Close Open ON Under low temperature limit Close Open Open Close INSTALLATION 4.84 in (123 mm) 1.92 in (49 mm) 1.18 in (30 mm) 2.16 in (55 mm) 2.99 in (76 mm) 2.32 in (59 mm) 3.30 in (84 mm) 5.47 in (139 mm) Figure 3 Detector Head Installation Dimensions: in(mm) 6
7 3.26 in (83 mm) 2.87 in (73 mm) 5.86 in (149 mm) 6.45 in (164 mm) 0.98 in (25 mm) 7.02 in (178.5 mm) Figure 4 Control Box Installation Dimensions: in(mm) MAINTENANCE Error Code Status Temperature Error Display Reason Action -- HI -- LO Target temperature is over range Target temperature is under range Use the thermometer within temperature range Use the thermometer within temperature range -- Ambient Temperature PHI is too high -- Ambient temperature PLO is too low Power malfunction Use the thermometer within ambient temperature range. Use the thermometer within ambient temperature range Check power or return the thermometer for repair Caution Detector head should be installed in a place without optical obstructions. Wipe dust off lens surface by using soft cloth or absorbent wadding moistened with lens cleaning agent. Do not take the thermometer apart. If there are malfunctions, return it to the factory for repair. 7
8 ACCESSORIES Detector Head with Cable 1 Control Box 1 Bracket 1 Instruction Manual 1 Figure 5 Sensor Head See pg 6, Figure 3 for Sensor Head Installation Dimensions 4. Operation Instructions for M15-GSL12P30S Sensor Head Only HOW TO USE Install detector head Keep this cable away from AC wires Use the RS485 connections and issue commands to the sensor as follows; 8
9 M15 Protocol Temperature Measuring Unit (TMU) Protocol Red Color Commend Sending to TMU Blue Color Comment Receiving from TMU Communication follows RS485 standard baud rate 9600 bit /s 8 data bits no check bit 1 stop bit Setup Temperature Measuring Unit(TMU) address: Range allowed 0~20 (Hexadecimal value) Send hexadecimal numeral XX 00 YY with their aggregate code (6 bytes total) XX Current of TMU, Range 0 ~ 20 YY New Address of TMU, Range 0 ~ 20 *No feedback from TMU Setup Emissivity: Range allowed 0~5AH Send hexadecimal numeral XX 01 YY with their aggregate code (6 bytes total) XX Address of TMU, Range 0 ~ 20 YY Emissivity, Range 00 ~ 5AH (0.10 ~1.00 with 0.01 increment) 00=0.10 5A= If the TMU address is valid, emissivity will change; otherwise no action will be taken. *No feedback from TMU Laser Setting: = ON = OFF Send hexadecimal numeral XX with their aggregate code (6 bytes total) XX Address of TMU, Range 0 ~ 20 - If the TMU address is valid, turn laser ON, otherwise no action will be taken. *No feedback from TMU Send hexadecimal numeral XX with their aggregate code (6 bytes total) XX Address of TMU, Range 0 ~ 20 - If the TMU address is valid, turn OFF laser, otherwise no action 9
10 will be taken. *No feedback from TMU Note: There is laser switch on back of TMU, laser can be turned on manually without RS485, and laser will last 30 seconds, then turn off Read Temperature: Range allowed 0~ Send hexadecimal numeral XX with their aggregate code (6 bytes total) XX = Address of TMU, Range 0 ~ 20 - If the TMU address is valid, TMU sends temperature back; otherwise no action will be taken Temperature format: Range allowed 0~ Hexadecimal numeral F0 XX AB CD with their aggregate code of AB CD F0 = SYNC Code XX = Address of TMU, Range 0 ~ 20 AB CD = Decimal temperature with +/- & C/F info + / - C / F Thousands Hundreds Tens Ones plus=0 minus=1 C =0 F =1 B C D A 1 st Byte = +/- (1 most significant digit), C/ F (1 digit), Thousands (2 least significant digits) Binary Hex output C, 0 Thousands C, 1 Thousands C, 2 Thousands C, 3 Thousands F, 0 Thousands F, 1 Thousands F, 2 Thousands F, 3 Thousands C, 0 Thousands 1100 C - F, 0 Thousands For example: -20 c = C = C = C = Resolution 1 C 0 F = F = F = F = Resolution 1 F 10
11 C / F Switch: Send hexadecimal numeral XX for C with their aggregate code (6 bytes total) XX = Address of TMU - If the TMU address is valid, Temperature unit is set to C; otherwise no action will be taken. *No feedback from TMU Send hexadecimal numeral XX for F with their aggregate code (6 bytes total) XX = Address of TMU - If the TMU address is valid, Temperature unit is set to F; otherwise no action will be taken. *No feedback from TMU Error Codes: When TMU receives reading order, if the unit is out of operational range, TMU will feedback with 6 bytes: FO = Sync Code, XX = Address of TMU F0 XX 0A FF - Reading is below Range Low Limit F0 XX 0A FE - Reading is above Range High Limit F0 XX 0A FD - Ambient temperature is lower than -10 C F0 XX 0A FC - Ambient temperature is higher than 50 C F0 XX 0A FB - TMU power is out of range Wiring RED: +12VDC@100mA BLACK: Ground YELLOW: 4~20 ma Positive, Negative goes Ground* GREEN: RS485-A BLUE: RS485-B * 4-20 ma current readings may be invalid during programming. Caution Detector head should be installed in a place without optical obstructions. Wipe dust off lens surface by using soft cloth or absorbent wadding moistened with lens cleaning agent. Do not take the thermometer apart. If there are malfunctions, return it to the factory for repair. 11
12 ACCESSORIES Detector Head with Cable 1 Bracket 1 Instruction Manual Old Weaverville Road Asheville, NC Phone: (828) , 12
13 Fax: (828) Web : 13
Black Body Calibration Source User Manual
Black Body Calibration Source Surface Plate Type with External Controller Model CBB18GC- 2 WD1069 Rev B 10/23/17 Wahl Instruments Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free: 800-421-2853
More informationInfrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm
User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature
More informationIRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology
E instruments IRtech Temperature range up to 2200 C Optical resolution up to 300:1 Close focus 0,5mm 8-14µm, 1.6µm, 1µm, 2.3µm, 3.9µm, 4.2µm, 4.6µm, 5.1µm and 7.9µm Spectral response Dual laser true target
More informationLaser Distance Sensor Type M Analog-Output
Laser Distance Sensor Type M Analog-Output Operating Manual Version 2.3, May 2009 ELAG Elektronik AG l Stegackerstrasse 14 l CH-8409 Winterthur Contents 1. Safety 1.1 Laser safety 1.2 Electrical safety
More informationSS-100. Pyrometer. Temperature Range: 800~2400
Two Color Non-Contact Pyrometer Temperature Range: 800~2400 SS-100 GasDNA Co.,Ltd C-910C, Bupyeong Woolim Lion s Valley, #425, Bupyeong-Gu, Incheon, Korea TEL: +82-32-623-7507 FAX: +82-32-623-7510 E-mail:
More informationFS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com
Model Infrared Food Thermometer FS-200 Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 3 Specifications... 4 Instrument Description... 5 Display Description... 5 Operating
More informationIRT2 Dual Laser IR Thermometer - User Guide
IRT2 Dual Laser IR Thermometer - User Guide TABLE OF CONTENTS Introduction Key Features 4 4 Operating Instructions - Front Panel Controls and Indicators - Switching Cº/Fº - On / Off - MODE settings menu
More informationRS Pro Infrared Temperature Sensor
Instruction Manual RS Pro Infrared Temperature Sensor Stock Number: 161-8103 Introduction The RS Pro Infrared Temperature Sensor is a device for measuring the temperature of the surface of a solid or liquid
More informationIMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!
USER GUIDE English IMPORTANT PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal. Contents
More informationSeries Temperature Controller Instruction Sheet
Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep
More informationFIRERAY 5000 range USER GUIDE
FIRERAY 5000 range USER GUIDE 0044-003-04 IMPORTANT PLEASE NOTE: The beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal.
More informationTable of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...
SECTION Table of Contents SECTION 1 INTRODUCTION...................... 1.1 Description............................... 1.2 Features................................. 1.3 Models..................................
More informationManual Instructions IR Measuring Instrument GIM 1840 ST60 / ST80
Manual Instructions IR Measuring Instrument GIM 1840 ST60 / ST80 isplay Anzeige Affichage Pantalla isplay C/ F Switch C/ F-Schalter Commutateur C/ F Interruptor de C/ F Chave C/ F Laser Laser Laser Láser
More informationReplaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge
Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays
More informationSeries Digital Controller Instruction Sheet
216/3/11 Series Digital Controller Instruction Sheet Thank you very much for purchasing DELTA DTC Series Temperature Controller. Please read this instruction sheet before using your DTC series to ensure
More informationPrecision Infrared Thermometer. Users Manual
Precision Infrared Thermometer Users Manual March 2005 2005 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. LIMITED WARRANTY AND LIMITATION OF LIABILITY
More informationNote To The User: This product has updated features not yet mentioned in the product manual.
PLEASE READ BEFORE OPERATING THE PRODUCT--- Note To The User: This product has updated features not yet mentioned in the product manual. Celsius / Fahrenheit toggle: To switch the reading between Celsius
More informationMotorised Infrared Optical Beam Smoke Detector. User Guide
Motorised Infrared Optical Beam Smoke Detector User Guide EN 1. General Information 50cm 50cm 8-100m Ensure clear line of sight from Detector to Reflector Mount on solid surfaces (structural wall or girder)
More informationUsers Manual. Visit us at
Users Manual 568 EX Infrared Thermometer 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com PN 4326622 June 2013 2013 Fluke Corporation.
More informationMotorised Infrared Optical Beam Smoke Detector. User Guide
Motorised Infrared Optical Beam Smoke Detector User Guide EN 1. General Information 50cm 50cm 8-100m Ensure clear line of sight from Detector to Reflector Mount on solid surfaces (structural wall or girder)
More informationKey Features. General Description
Key Features SIL2 rated, for certified dependability (fail-safe detection) Special coating for electronics protection in harsh environments Dedicated temperature range, for maximum detection accuracy Individual
More informationDual Laser InfraRed (IR) Thermometer
User Manual Dual Laser InfraRed (IR) Thermometer MODEL 42512 Introduction Congratulations on your purchase of the Model 42512 IR Thermometer. This Infrared thermometer measures and displays non-contact
More informationSM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option
SM3000 Videographic Recorder User Guide (RTU) Communications Option ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow
More informationPinless Moisture/Humidity Meter with Memory + IR Thermometer
User's Guide Pinless Moisture/Humidity Meter with Memory + IR Thermometer Model MO295 mbar GPP RH% 01 MEM STORE MO295 Introduction Congratulations on your purchase of the Extech MO295 Pinless Moisture
More informationPrecision Infrared Thermometer. Users Manual
Precision Infrared Thermometer Users Manual March 2005 2005 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. LIMITED WARRANTY AND LIMITATION OF LIABILITY
More informationEthernet General Purpose
Ethernet General Purpose Technical Manual Revision 1.03 8 November 2013 Pakton Technologies IO PAE224 Ethernet GPIO Manual.docx Page 1 of 22 Revision 1.03 Last updated 8/11/2013 Table of Contents INTRODUCTION...3
More informationRevision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual
Revision 1.03 8 November 2013 JVA Technologies Ethernet General Purpose IO Technical Manual www.jva-fence.com.au Table of Contents INTRODUCTION...3 Scope and Purpose...3 Glossary...3 SPECIFICATIONS...4
More informationGeneral Purpose IO Technical Manual
General Purpose IO Technical Manual Revision 1.06 8 November 2013 Pakton Technologies PAE222 GPIO Manual.docx Page 1 of 21 Revision 1.06 Last updated 8/11/2013 Table of Contents INTRODUCTION...3 Scope
More informationBeam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications
Non-contact Thermometers Portable Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio Temperature range from -58 to 1832 F (-50 to 1000 C)! Built-in
More informationMore Precision. thermometer // Non-contact IR temperature sensors
More Precision thermometer // Non-contact IR temperature sensors 48 Compact OEM infrared sensor with external controller thermometer CSmicro thermometer CSmicro Miniature OEM infrared temperature sensor
More informationModline. 5 Stand Alone Temperature Sensor. You can bet your process on it!
Modline 5 Stand Alone Temperature Sensor You can bet your process on it! Modline 5 Infrared Thermometer - you can bet your process on it! If reliable and accurate temperature measurement is imperative
More information64 Max IR Thermometer
64 Max IR Thermometer Users Manual January 2017 2017 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
More informationFlameGard 5 UV/IR HART
FlameGard 5 UV/IR HART HART Communication Manual The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized
More informationMiniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)
PSC-SSS-PM Series Miniature Infrared Temperature Sensors with Optional Touch Screen Display PSC-SSS-PM with touch screen display (- version) FEATURES Miniature sensing head and configurable electronics
More informationANEMOMETER 4403-RF-BAT
ANEMO 4403 Radio impulsive output Anemometer - Wireless Robust wind speed sensor,extremely resistant and flexible, Suitable for many different application. Stainless steel bearings and high quality technical
More informationCCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800
SENSORS & SYSTEMS Authority in Displacement Measurement CCD-Precision high accuracy and resolution compact sensor design 5 khz frequency N ILD 1800 TRIANGULATOI PRINCIPLE OPTO NCDT Intelligent Laser-Optical
More informationOPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL
ap15_2manual04/22/13 Page 1 4/22/2013 1 Serial Number : Option: OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL Micro Seven, Inc. 1095-K N.E. 25th Hillsboro, OR 97124 U.S.A. phone: 503-693-6982
More informationI/R Thermometer Gun 12:1
I/R Thermometer Gun 12:1 800103 INSTRUCTION MANUAL SPER SCIENTIFIC Contents Page 1. Introduction... 2 2. Safety Information... 3 3. Display And Button Locations... 4-5 4. Distance to Spot... 5 5. Measuring
More information62 MAX/62 MAX + Infrared Thermometer. Users Manual
62 MAX/62 MAX + Infrared Thermometer Users Manual Introduction The Fluke 62 MAX and 62 MAX + Infrared Thermometers (the Product) can determine the surface temperature by measuring the amount of infrared
More informationWIO500 and WIOI500 Water in oil sensor
WIO500 and WIOI500 Water in oil sensor User manual Rev. 1.08 111881-942 Rev. 1.08 User manual 500 Date: 2017-01-20 03-01-0501-CRJ-04 Side 1 af 79 Table of contents Table of contents... 2 Introduction...
More informationManual PCE-889 pyrometer
www.pce-industrial-needs.com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co. Durham DH6 5PG United Kingdom Phone: +44 ( 0 ) 191 377 3398 Fax: +44 ( 0 ) 191 377 3357 info@tursdaletechnicalservices.co.uk
More informationDual Laser InfraRed (IR) Thermometer
User Manual Dual Laser InfraRed (IR) Thermometer MODEL 42512 Introduction Congratulations on your purchase of the Model 42512 IR Thermometer. This Infrared thermometer measures and displays non-contact
More informationCA876 INFRARED K-THERMOMETER WITH LASER ENGLISH. User Manual. Auto OFF
Auto OFF INFRARED K-THERMOMETER WITH LASER CA876 ENGLISH User Manual Owner s Record The serial number for the Model CA876 is located inside the battery compartment of the instrument. Please record this
More informationSeries SHR-5620 Digital Display Volumetric Meter Operation Instruction
Series SHR-5620 Digital Display Volumetric Meter Operation Instruction Version: 5620-110722 1. Introduction SHR-5620 Digital Display Volumetric Meter,Produced by full-automatic chip mounter with surface
More informationT3/E3 Fiber Optic Line Drivers
MT618A-ST-R3 January 2004 MT619A-ST-R2 MT620AE-R2 T3/E3 Fiber Optic Line Drivers CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical
More informationPTE0705 Electric Fence Monitor
PTE0705 Electric Fence Monitor The JVA logo is a registered trademark of JVA Technologies. JVA Technologies. TABLE OF CONTENTS DESCRIPTION... 2 QUICK START GUIDE... 3 FEATURES... 4 EXPLANATION OF TERMS...
More informationOperator s Manual. optris CT LT/ LTF/ LTH/ 1M/ 2M/ 3M/ G5/ P3/ P7. Infrared-thermometer
Operator s Manual optris CT LT/ LTF/ LTH/ 1M/ 2M/ 3M/ G5/ P3/ P7 Infrared-thermometer Optris GmbH Ferdinand-Buisson-Str. 14 13127 Berlin Germany Tel.: +49 30 500 197-0 Fax: +49 30 500 197-10 E-mail: info@optris.de
More informationDC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1
DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS User Manual and Menu Map A4741 / Rev.1 www.entes.com.tr ATTENTION -Disconnect all power before connecting the device. -Don t remove
More informationInstruction Manual CTVM-3H3 CTVM-2L CTVM-2H CTVM-2H1 CTVM-3L CTVM-3H CTVM-3H1 CTVM-3H2 CTVM-1L CTVM-1H CTVM-1H1
Instruction Manual thermometer CTVideo CTVM-1L CTVM-1H CTVM-1H1 CTVM-2L CTVM-2H CTVM-2H1 CTVM-3L CTVM-3H CTVM-3H1 CTVM-3H2 CTVM-3H3 Infrared sensor MICRO-EPSILON MESSTECHNIK GmbH & Co. KG Königbacher Strasse
More informationFL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com
FL500 Modbus Communication Operating Manual Order No.: 10193214/00 MSAsafety.com 1000 Cranberry Woods Drive Cranberry Township, PA 16066 A Phone 1-800-MSA-2222 Fax 1-800-967-0398 For your local MSA contacts
More informationMini InfraRed (IR) Thermometer with Type K Input and Laser Pointer
USER MANUAL Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer MODEL IR267 Introduction Thank you for selecting the Extech Model IR267 Mini IR Thermometer. The Model IR267 IR thermometer
More informationHigh Temperature InfraRed Thermometer with Laser Pointer
User s Manual High Temperature InfraRed Thermometer with Laser Pointer MODEL 42545A Introduction Congratulations on your purchase of the Model 42545A IR Thermometer. The 42545A is capable of non-contact
More informationCTlaser LT/ 1M/ 2M/ CTglass
CTlaser LT/ 1M/ 2M/ CTglass Infrared Sensor Operators manual CE-Conformity The product complies with the following standards: EMC: EN 61326-1 Safety Regulations: EN 61010-1:1993/ A2:1995 The product accomplishes
More informationTable of Contents SECTION PAGE
Table of Contents SECTION PAGE SECTION 1 INTRODUCTION................... 1.1 Description.............................. 1.2 Features................................ 1.3 Models.................................
More informationMore Precision. thicknesssensor // The sensor for precise thickness measurements
More Precision thicknesssensor // The sensor for precise thickness measurements 2 The sensor for precise thickness measurements thicknesssensor - Immediately ready for use due to perfectly harmonized components
More informationModel 3300 Technical Support and Installation Manual
Model 3300 Technical Support and Installation Manual Manual # T15011 Document Revision: A1 1. OVERVIEW 1 2. BASIC OPERATION 1 2.1 General 1 2.2 Field-of-View 2 2.3 Range 2 2.4 Environment 2 2.5 Configuration
More informationAnalog Input Module IC670ALG630
1 IC670ALG630 The Thermocouple (IC670ALG630) accepts 8 independent thermocouple or millivolt inputs. Module features include: Self calibration Two data acquisition rates based on 50 Hz and 60 Hz line frequencies
More informationUser s Guide OS210-C4. IR Temperature Sensors. Shop online at omega.com. For latest product manuals: omegamanual.
User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info MADE IN UNITED KINGDOM OS210-C4 IR Temperature Sensors OMEGAnet Online Service omega.com Internet
More informationMore Precision. thermometer // Non-contact infrared temperature sensors
More Precision thermometer // Non-contact infrared temperature sensors 2 Measuring principle thermometer Non-contact temperature measurement - precise and reliable. Temperature measurement with Micro-Epsilon
More informationPinless Moisture/Humidity Meter with Memory + IR Thermometer
User's Guide Extech MO295 Pinless Moisture Psychrometer w/ IR Thermometer Extech MO295-NISTL Pinless Moisture Psychrometer w/ IR Thermometer Pinless Moisture/Humidity Meter with Memory + IR Thermometer
More information2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.
SYNRAD, Inc. 4600 Campus Place Mukilteo, WA 98275 tel 1.425.349.3500 fax 1.425.349.3667 e-mail synrad@synrad.com web www.synrad.com Power Wizard PW-250 Operating Instructions Important Power Wizard power
More informationModel 1062 Environment Monitor
Model 1062 Environment Monitor Continuously Monitors Environment Temperature Humidity Barometric Pressure Line Voltage Line Frequency Applications Manufacturing The 1062A Environment Monitor will ensure
More information62 MAX/62 MAX + Infrared Thermometer. Users Manual
Infrared Thermometer Introduction The Fluke 62 MAX and 62 MAX + Infrared Thermometers (the Product) can determine the surface temperature by measuring the amount of infrared energy radiated by the target
More informationMETEOROLOGICAL INSTRUMENTS
METEOROLOGICAL INSTRUMENTS INSTRUCTIONS WIND TRACKER MODEL 06206 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com
More information1. Quick start-up guide
1. Quick start-up guide This quick guide leads the way to install, start-up and configure necessary parameters in the normal cases. 1. PREPARING INSTALLATION Install fiber optic cable inside conduit. This
More informationSENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -
The sensor is designed for frequent washdowns with a corrosion-resistant AISI316L stainless steel case IP69K rated, compliant to test environments like indicated by Diversey and Ecolab. However, all models
More informationWide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer
User Manual Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer MODEL 42515 Introduction Congratulations on your purchase of the Model 42515 IR Thermometer. The Model 42515 IR thermometer
More informationPHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1
PHOTOELECTRIC DUAL BEAM DETECTOR Manual R4222 RECEIVER INDICATORS 1 PARTS GOOD LEVEL ALARM COVER Connection s Indicators Wiring Knockout Response Time Adjustment (only for receiver) Signal Level Test Points
More informationPH/ORP PH/ORP Tester. Instruction for use
PH/ORP PH/ORP Tester Instruction for use Catalogue PH/ORP CONTROLLER--MANUAL Preface...2 Notice...2 User instructions...3 Chapter I Brief introduction on product... 4 Characteristics...4 Technical index...5
More informationType TEC, Transformer Electronic Control System
Type TEC, Transformer Electronic Control System Technical Guide 1ZSC000857-AAB en, Rev. 2, 2006-06-15 Declaration of conformity The manufacturer ABB Power Technologies AB Components SE-771 80 LUDVIKA Sweden
More informationS304 and S305 Dust Emission Monitors. User Manual. Distributor
S304 and S305 Dust Emission Monitors User Manual Distributor Version 6.4 30/5/2012 Table of Contents 1. INTRODUCTION... 3 1.1 Safety... 3 1.2 Product overview... 4 1.3 Principle of operation... 4 2. INSTALLATION...
More information2-inch HDCVI Speed Dome Installation Manual
2-inch HDCVI Speed Dome Installation Manual Version 1.0.1 Table of Contents 1 INSTALLATION PREPARATION... 1 1.1 Basic Requirements... 1 1.2 Installation Check... 1 1.3 Cable Preparation... 1 1.3.1 Cable
More informationCCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800
SENSORS & SYSTEMS Authority in Displacement Measurement CCD-Precision high accuracy and resolution compact sensor design 5 khz frequency N ILD 1800 TRIANGULATOI PRINCIPLE OPTO NCDT Intelligent Laser-Optical
More informationStratos Optical HD/SD BNC to "ST" Video Media Converter (Transmitter)
FEATURES: SMPTE 292M/297M/259M/305M compliant (VMC-T- H-2) SMPTE 259M/297M/305M compliant (VMC-T-S-2) DVB/ASI compliant (VMC-T-H-2 and VMC-T-S-2) ATSC/SMPTE 310M compliant; 19.4 to 38.8Mbps (VMC-T-H-2
More informationM004 combustible gas module
M004 combustible gas module M004 combustible gas module Introduction: M004 gas module can change the concentration of combustible gas in the air into digital signal output. It uses three-line system 4-20mA
More informationInfrared Temperature Sensor
Infrared Temperature Sensor With High Speed Sensor, Small Measured Spot and Continuous LED Sighting OS-PC Series U High Speed Cube Sensor with Optional Touch Screen Display U Response Time 0.001 Seconds
More informationR2310. Infrared Thermometer. Instruction Manual
R2310 Infrared Thermometer Instruction Manual Table of Contents Introduction... 3 Product Quality... 3 Safety... 3 Features... 4 Included... 4 Specifications...4-5 Instrument Description... 6 Display Description...
More informationTemperature Controllers
Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65
More informationST Wiring diagram. Product description. Four-stage controller. Order number
ST96-35.16 Four-stage controller Order number 99.2 Wiring diagram Product description The four-stage controller with 4-digit setpoint and actual value display, 3 keys and 4 relays was developed for the
More informationUser Detection Sensors
User Detection Sensors Design Team 5 Kevin Harrison Eric Hosey Leslie Hodges Nathan Kelly Berna Saracoglu Agenda Sensing Technologies Infrared Ultrasonic Capacitive Pressure Video Image Key Points Theory
More informationSerie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)
Serie 5000 Tel. +1 (0)5 222 Fax +1 (0)5 222 12 PRODUCT INTRODUCTI PRODUCT INTRODUCTI 5 Series programmable temperature controller is FineTek's mid-range series of controllers. It uses a 12bit analog /
More informationRC-122BZ Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool Thermostat Installation Instructions
RC-122BZ Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool Thermostat Installation Instructions DESCRIPTION The RC-122BZ is a precision digital thermostat designed for 24 VAC two-stage heating and cooling
More information62 MAX/62 MAX + Infrared Thermometer
62 MAX/62 MAX + Infrared Thermometer Users Manual Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com PN 4060712 April 2012 2012 Fluke Corporation. All rights
More informationUser's Guide. CO 2 Monitor. Model CO200
User's Guide CO 2 Monitor Model CO200 Introduction Congratulations on your purchase of this Model CO200 Carbon Dioxide Meter. This meter measures CO2 level, air temp., humidity, date and time. With visible
More informationP2267 NETWORK INTERFACE
P2267 NETWORK INTERFACE USER MANUAL FOR OPERATING SYSTEMS: 22031-03 23636-01 October 2009 Associated Controls (Australia) Pty. Limited 2-4 Norfolk Road Greenacre, NSW, 2190. PH +61 2 9642 4922, FAX +61
More informationProduct Manual SZ1144
Product Manual SZ1144 Refrigeration Temperature Monitor Communicating Controls Description The SZ1144 is a microprocessor-based monitoring and alarm interface designed to monitor up to four 1000 Ω platinum
More informationMark 25 Ultrapure Water Conductivity Analyzer
Martek Instruments, Inc. Mark 25 Ultrapure Water Conductivity Analyzer Instruction Manual WARRANTY POLICY Unless otherwise stated, MARTEK INSTRUMENTS, INC. warrants this equipment to be free from defects
More informationAE500 Instruction Manual
Digital Indicator with Alarm function AE500 Instruction Manual IMAE01-E8 Thank you for purchasing this RKC product. In order to achieve maximum performance and ensure proper operation of your new instrument,
More informationErbium-Doped Fiber Amplifier (EDFA) - MW Series
Nanovation s MW series of EDFA products is designed for applications in advanced dense wave division multiplexing (DWDM) systems where high performance and reliability are critical. They are available
More informationoptris CSmicro LT/ 2WLT/ 2W2M/ 3M Operators manual Infrared Sensor
optris CSmicro LT/ 2WLT/ 2W2M/ 3M Infrared Sensor Operators manual CE-Conformity The product complies with the following standards: EMC: EN 61326-1:2006 (Basic requirements) EN 61326-2-3:2006 Safety Regulations:
More information62 MAX/62 MAX + Infrared Thermometer
62 MAX/62 MAX + Infrared Thermometer Users Manual PN 4060712 April 2012 Rev. 1, 11/12 2012 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice.
More informationoptris TM Temperature Monitor for Infrared Sensors Operators manual
optris TM Temperature Monitor for Infrared Sensors Operators manual CE-Conformity The product complies with the following standards: EMC: EN 61326-1:2006 (Basic requirements) EN 61326-2-3:2006 Safety:
More informationBacnet Room Setpoint & Temp Display. Descriptions. Specifications
Descriptions Bacnet Room Setpoint & Temp Display is designed for environment monitoring and controlling in industrial, commercial and other buildings. These transmitters can be used to monitor air temperature
More informationApollo Intelligent Auto Aligning Beam Detector. User Guide
Apollo Intelligent Auto Aligning Beam Detector User Guide EN 1. General Information 50cm 50cm 8-100m Ensure clear line of sight from Detector to Reflector Mount on solid surfaces (structural wall or girder)
More informationInstruction Manual Model Backup Switch, 1 for 8
Instruction Manual Model 2582-282 Backup Switch, 1 for 8 December 2011, Rev. 0 MODEL 2582 SWITCH CROSS TECHNOLOGIES INC. SWITCH ALARM PSA PSB ALARM OFFLINE ONLINE UNIT STATUS 1 2 3 4 5 6 7 8 BU PROT MODE
More informationInstallation Guide & User Manual
Installation Guide & User Manual Standalone Metal RFID Series Version: 2.1 Date: January, 2015 Important Note Document Privacy Note: Firstly thank you for purchasing the product. Before use, please read
More informationMeasurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible
Measurement & Analytics Measurement made easy LLT100, LM80, and LM200 Lasers for level: Now everything is possible Expertise in technology from more than a century of experience To operate any process
More informationF4 Process Controller Installation and Operation Guide
F4 Process Controller Installation and Operation Guide 1.Introduction 1.1.Highlight Features Space saving, only 55mm panel depth required Higher sampling rate (1mS) results in better control performance
More informationInstruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &
1622i_Manuals 12/14/16 12:52 PM Page 1 Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No. 40-6685, 40-6687 & 40-6688 Instruction Manual Congratulations on your choice of this
More informationUser's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295
User's Guide Pinless Moisture/Humidity Meter with Memory + IR Thermometer Model MO295 Introduction Congratulations on your purchase of the Extech MO295 Pinless Moisture Meter with Patented Built-in IR
More information