1 Alarm Systems SERIAL PRODUCTS Digital Alarm Annunciator ME 3011b Instruction Manual Manual ME3011b_E_v0707_Pre.doc 1/50

2 1 Information and Technical Data Introduction 4 Warranty 4 Installation 5 Operation Principles 6 Technical Data 7 Modularity and arrangements 9 Dimensions 10 Panel Mounting 11 Product Identification 12 Product Code 13 Front display engraving/printing 14 Signaling sequences 15 Special Options 16 2 Product Description CM-0x Master CPU s Module 17 Master CPU 2v x 4h 17 CM-04 Master CPU 4x x 2h 18 SM-02 Slave CPU Module 20 EM-0x - Expansion Modules 21 EM-02 Expansion Module 2v x 4h 21 EM-03 Expansion Module 4v x 2h 22 EM-04 Expansion Module 2v x 2h 23 Functions Installation Power Supply 26 Inputs 27 Alarm Inputs 27 Remote push-button 27 GPS Synchronization (Option) 28 Power consumption 32 Outputs 29 24Vdc field output 29 External Buzzer output 29 Programmable relay outputs 29 Repeater relay outputs (RRO) (Option)l 29 Repeat relays for power fault detection (Option) 30 Flashing synchronization (Option) 31 Recommendations 32 Connection diagram examples 33 Standard connections 24 Vdc without RRO or Special 33 Connections with Vdc Fault at Point 2 and Vac Fault at Point 4 35 Terminal identification 37 New arrangements 41 SM-02 module positions 42 SM-02 position on 4h enclosure 42 SM-02 position on 8h enclosure 43 SM-02 position on 12h enclosure 44 Manual ME3011b_E_v0707_Pre.doc 2/50

3 SM-02 position on 16h enclosure 45 Configuration modes e.tool ME3011 config - Configuration via serial interface 5 - Configuration via keyboard 6 Communication Protocol - Serial Modbus RTU 7- e.tool ME2011 view This manual is subject to changes without previous advice Revision Control Author Version/Rev Date mbe 0 16/07/2007 Manual ME3011b_E_v0707_Pre.doc 3/50

4 INTRODUCTION Dear Customer, Mauell thanks you for trusting us on choosing our products. It is a pleasure to provide you all necessary information on the newest member of its Mauell annunciator family. This manual presents all information needed to connect and power up the annunciator, as well as instructions for configuring it. Mauell hopes that this manual helps you explore totally the potential of the new ME 3011 annunciator. Please contact us, if any doubt persists about the equipment operation, after reading it. Our technical team is always available to clear any doubt you may deem necessary. Contact the nearest Mauell unit (please refer to the appendix) or send an to mauell@mauell.com.br; visit the website send a fax to or call In order to help us on our support service have the series number and the firmware version with you, as these data are essential for clearing the doubts and for technical assistance. WARRANTY The equipment manufactured and supplied by Mauell is guaranteed against any project and manufacturing defect, when stored and used according to its technical characteristics, for a 12 (twelve)-month period from its installation or 18 (eighteen) month-period from the ex works delivery date (which is the earliest). During this period, Mauell will replace or correct, without any charges to the client, all out of technical specification equipment parts. In other words, our warranty covers materials and labor in the correction of eventual defects eligible for being covered by our warranty. These operations will be carried out in our nearest unit (as previously agreed upon) or at Helmut Mauell do Brasil to where the equipment may be sent. In case of doubt about the use of the equipment, due to the warranty and its effects, please contact our commercial and technical departments. Manual ME3011b_E_v0707_Pre.doc 4/50

5 INSTALLATION All annunciators have an appropriate package for air or road transportation. When receiving the equipment, the visual inspection may be carried out to check if there were damages during transportation. If so, it is necessary to contact immediately the receiving sector of your company, which may notify your insurance company and Mauell so the involved parts may adopt the necessary measures to repair the damages and to initiate the reimbursement of eventual expenses. The incorrect use and wrong handling of the equipment are not covered by Mauell general guarantee. Therefore, it is essential that the installer takes some measures, before executing the installation and powering of the equipment, as mentioned below: Avoid mechanical impacts to the equipment or falls, which cause frame arching or back terminal breaking. Avoid that water or other liquid gets into the annunciator, as the liquid may cause shortcircuit to the internal circuits and, consequently, bad contacts in the future. Avoid that external objects get into the annunciator through the vents, thus, whenever it is necessary to carry out any work involving drilling or panel plate thinning, where the annunciator is installed, the equipment may be protected with paper, plastic and other material so the debris do not get into the annunciator, causing poor operation. Check the voltage levels and the correct identification of the cables before executing the equipment connection. A wrong connection can cause short-circuit and damage to the equipment in an irreparable way. The frontal modules may be removed with the aid of a blade, which may be inserted between two modules, carefully, forcing the removal of the desired module. This operation may be carried out carefully and patiently in order to prevent damages to the front part of the modules or to the grid brackets of the module. The access to the electronic circuits of the equipment is carried out from the front part, removing the front modules, as described above, disconnecting the back pluggable terminals, without disconnecting the wires, from which the electronic part of the equipment may be removed. After the repair, the electronic part may be replaced and the terminals plugged again. When reconnecting, note with the maximum care, the proper position of each terminal. The cleaning of the front part of the annunciator may be carried out with a soft cloth, slightly wet, with neutral detergent. The equipment may not be submitted to the direct spray of liquids and care must be taken so the liquids do not get into it. Manual ME3011b_E_v0707_Pre.doc 5/50

6 OPERATION PRINCIPLES Alarm annunciators have the main function of safely signaling critical statuses of installations, aiming at their integrity. They signal acoustically and optically equipment alarms in a standardized way, within the highest ergonomic and cognitive possible standard. It is recommended, in general, to carry out the direct connection of electric field alarm signals to the annunciator, preventing loops through digital automation and control systems. Thus, the necessary operating safety level is achieved. The maximum alarm signal cable length is 600 m (unshielded) or 1000 m (shielded). These maximum values may be strongly reduced in areas with very high electromagnetic fields, for example in the case of open air cable trays within substations. It is, also, of paramount importance to place the signal cables in trays carrying cables with homogeneous voltages. Placing high and low voltage cables in conjunction within the same cable tray may cause serious annunciator malfunctions or even hardware damages. The ME 3011 annunciator, the new member of Mauell annunciator family, keeps one of the most important characteristics of ME 3010 series, which is the modularity of the alarm windows. The processing fundament of the alarm signs is now carried out through latest generation micro controllers, with high performance RISC architecture. So, ME 3011 annunciator incorporates all the advantages of a micro processed system, such as configuration of the annunciators main functions through the front keyboard, or also via configuration software, available at for download. This way, the ME 3011 annunciator provides all conventional functions of alarm announcing together with new and advanced communication function in local network and event recording, among others. These functions will be described in details throughout this manual. Manual ME3011b_E_v0707_Pre.doc 6/50

7 TECHNICAL DATA 1 - Supply Voltage 1.1 PS-05 Power Supply 24 Vdc ± 20% 1.2 PS-06 Power Supply (Option) Input: 19 to 264 Vdc and / or 90 to 264 Vac Auxiliary field output: 24Vdc / 0,75A 1.3 Special Option PSFD Power Supply Fault Detector (PSFD) for Vdc and/or Vac 1.4 Note: All power supplies are integrated into the annunciator 2 - Inputs Alarm Inputs 4 up to Isolation Opto couplers Input Voltages 24, 48, 60, 110 / 125 Vdc ± 20%; 110 / 127, 220 Vac ± 20% Input Current Input Filter External Push-Button Station Isolation Functions Synchronism with GPS and/or Flashing Isolation 3 ma (typical) lower value = 5 ms, programmable in steps of 2.5 ms 24Vdc Opto couplers Sound Acknowledge (HA), Light Acknowledge (LA), Reset (RE), Light Test / Function Test, Sleep Mode (SLM), Keyboard OFF (KB OFF) 24Vdc Opto couplers 3 - Outputs 3.1 Relays 3 contact free freely programmable relays for various functions, e.g., external buzzer, voltage fault, alarm group, etc 3.2 Sound Indication 90 db / 10 cm, 4 khz 3.3 Repeat relays (Option) 1 contact for each alarm point, as option Note: Field Voltages over 125 Vdc or Vac do not support repeater relays. 3.4 Repeat relays for Power Supply Fault Detector (PSFD) (Option) Note: 1 contact for each Power Supply Fault detector (PSFD) Contact capacity for all relays is 5A / 24Vdc for resistive load. Maximal switching voltage: 125Vdc/250 Vac 4 - Interfaces 4.2 Communication RS232C (Option) 4.3 Communication (Option) RS232C bi-directional Baud rate: 9600,n,8,1 Protocol: Modbus RTU (Slave) or Modbus RTU (Slave)+TS RS 485 Bi-directional serial communication (configurable) Baud rate: 100 a Parity: even, odd or none Stop bits: 1 or 2 Protocol: Modbus RTU (Slave) Manual ME3011b_E_v0707_Pre.doc 7/50

8 TECHNICAL DATA 5 - Event Register (Option) 5.1 Events 1000, with Time Stamp 5.2 Resolution 1 ms, samples 2,5 ms 5.3 Interfaces RS232C or RS Protocols Modbus RTU (Slave) 6 - Visualization Light Indication 6.1 Back light Ultra Bright Back light Back Light Socket (Option) Available in red, yellow, green, white and blue colors Available in red, yellow, green, white and blue colors Available in red, yellow, green, white and blue colors, on sockets to allow color change at the field. Led Special Option 6.2 Flashing frequency Windows Dimension 6.3 Back light Led 5 mm visible red, yellow, and green color leds More than 1 color per annunciator Fast: approx. 1.2 Hz Slow: approx. 0.4 Hz 24 x 48 mm White translucent modules Gray RAL 7032 polycarbonate modules 7 General Alarm sequence Environment ISA 1, 1A, 1B, 2A, 2C, 4A, 4AR; others on request Operation temperature: 0 to 55 C Storage temperature: -20 to 80 C 7.3 Protection class Relative Humidity: 0 to 95 %, without condensation Front: IP41 Enclosure: IP Isolation 3000 V eff : IEC FAZER com Lote Piloto!!! 7.5 EMC Compliance Immunity: DIN EN Emission: DIN EN ESD DIN EN Electromagnetic Field Immunity DIN EN RF Frequency Immunity DIN EN Burst DIN EN Surge DIN EN Voltage Dips DIN EN Terminals Terminal connectors (removable) for cables up to 2.5 mm² 7.13 Tropicalization Special Option Manual ME3011b_E_v0707_Pre.doc 8/50

9 The minimum configuration possible for the annunciator is a central module with 4 alarm points, and dimension of 2V x 4H or 4V x 2H. (see shaded portion on lower right corner of diagram below) Expansion modules can be added to this central unit, with 4 or 8 alarm points each, always in 2V x 2H or 2V x 4H modularity basis. So the subsequent configurations are: 8, 12, 16, 20, 24, 28 points and so on, up to a maximum of 252 alarm points. The module arrangement follows the diagram below. MODULARITY AND ARRANGEMENTS Number of horizontal points (h) y = 12 24vx8h= 188P 24vx4h= 92P 24vx2h= 44P y = 11 22vx8h= 172P 22vx4h= 84P 22vx2h= 40P y = 10 20vx12h= 236P 20vx8h= 156P 20vx4h= 76P 20vx2h= 36P y = 9 18vx12h= 212P 18vx8h= 140P 18vx4h= 68P 18vx2h= 32P Número de Módulos na Vertical y = 8 y = 7 y = 6 y = 5 16vx16h= 252P 14vx16h= 220P 12vx16h= 188P 10vx16h= 156P 16vx12h= 188P 14vx12h= 164P 12vx12h= 140P 10vx12h= 116P 16vx8h= 124P 14vx8h= 108P 12vx8h= 92P 10vx8h= 76P 16vx4h= 60P 14vx4h= 52P 12vx4h= 44P 10vx4h= 36P 16vx2h= 28P 14vx2h= 24P 12vx2h= 20P 10vx2h= 16P Number of vertical poinsl (v) y = 4 8vx16h= 124P 8vx12h= 92P 8vx8h= 60P 8vx6h= 44P 8vx4h= 28P 8vx2h= 12P 8 7 y = 3 6vx16h= 92P 6vx12h= 68P 6vx10h= 56P 6vx8h= 44P 6vx6h= 32P 6vx4h= 20P 6vx2h= 8P 6 5 y = 2 4vx16h= 60P 4vx14h= 52P 4vx12h= 44P 4vx10h= 36P 4vx8h= 28P 4vx6h= 20P 4vx4h= 12P 4vx2h =4P 4 3 4vx2h =4P 4 y = 1 2vx16h= 28P 2vx14h= 24P 2vx12h= 20P 2vx10h= 16P 2vx8h= 12P 2vx6h= 8P 2vx4h =4P CM-0x 2 1 CM ,5 3 2,5 2 1,5 1 0,5 Number of horizontal modules 2vx4h =4P 4 3 Min. arrangements Enclosure arrangement: Nr. of Points Arrangement Nr. of Points Arrangement Manual ME3011b_E_v0707_Pre.doc 9/50 Nr. of Points Arrangement Nr. of Points Arrangement 4v x 2h 16v x 2h 28v x 2h v x 8 h 4 2v x 4h 8v x 4h 52 14v x 4h v x 12 h 28 2v x 6h 4v x 8h 4v x 14h 16v x 8h v x 2h 2v x 16h 10v x 6h 8v x 16h 56 8v x 2h 18v x 2h 6v x 10h 18v x 8h v x 4h 6v x 6h 16v x 4h 12v x 12h 2v x 8h 20v x 2h 60 8v x 8h 20v x 8h v x 2 h v x 4 h 4 v x 16 h 10 v x 16 h 16 2v x 10h 4v x 10h 18v x 4h v x 12 h v x 2 h 40 22v x 2h 6v x 12h v x 8 h 6v x 4h 12v x 4h 20v x 4h 24v x 8h v x 6h 8v x 6h 10v x 8h v x 12h 44 2v x 12h 6v x 8h v x 4 h 12 v x 16 h 14v x 2h 4v x 12h 24v x 4h v x 12 h 24 2v x 14h v x 2 h 12 v x 8 h v x 16 h 92 8v x 12h v x 12 h 6v x 16h v x 16 h

10 DIMENSIONS Points Cutout table [height (h) x width (v)] mm h (x) v (y) 2 65 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 401 Manual ME3011b_E_v0707_Pre.doc 10/50

11 PANEL MOUNTING Each ME 3011 is shipped with a certain amount of panel clamps according the annunciator s size. 1 Locate the panel clamps inside the packing box and prepare the mounting 2 Insert the annunciator into the cutout 3 Insert the panel clamps into the lateral orifice, selecting the sides that provides the best mounting 4 - Srew, pressing lightly onto panel front plate Panel clamp Manual ME3011b_E_v0707_Pre.doc 11/50

12 PRODUCT IDENTIFICATION 1 Identification Label ME3011b Alarm Annunciator Code: D Serial #: 07/b1001 FW: Field: 24 Vdc Power Supply: Vdc / Vac Helmut Mauell do Brasil Indústria Brasileira / Made in Brazil / Fabriqué au Brésil 1.1 Code Product code with 15 digits 1.2 Serial# Product serial number YY/9999, where YY is the year and 9999 is a sequential number 1.3 FW: Identifies the firmware version from the annunciator YYMMDD999 = year, month, day and firmware version 1.4 Power Supply: Power supply voltages Standard: Vdc/90-264Vac With Power Supply Fault Detector (PSFD) are specified the requested voltages. Example: Digit 7 = E, indicates this option and the voltages specified by the customer was 125Vdc and 220Vac: 125Vdc/220Vac 1.5 Field: Indicates the field voltage of the annunciator Manual ME3011b_E_v0707_Pre.doc 12/50

13 PRODUCT CODE Go to the ME3011b Codification: ME3011b - Code FE ME3011b BL Alarm Annunciator - 12 Alarm Points - 2V x 8H: Power Supply Vdc / Vac - PSFD at Keyboard, BL 5 Colors, 110/125 Vdc Field Voltage with RRO, RS232C (R) + RS485 + ER + GPS Sync, Modbus RTU (Slave) + ER, with Engraving and Special Options F E ME3011b QTY = PC Code: FE Dígito > Nr. of Points 012 Enclosure 012P - 2V x 8H Field Voltage RRO (Repeater Relays) 110/125 Vdc 110/125 Vdc 12 0 Power Supply Vdc / Vac - PSFD at Keyboard Power Supply Fail Detector 110 Vdc 220 Vac PSFD Vdc Vac Set the PSFDs Voltages!! Tropicalization no (Standard) Light Indication Only for more that one color BL 5 Colors R 7 Y 2 G 1 B 1 W 1 TOT= 12 = Nr. of Points B and W only for Back Light Set Quantity for each color! Interface RS485 Protocol Engraving RS232C (R) + RS485 + ER + GPS Sync Modbus RTU (Slave) + ER Low relief 2 Lines ISA Sequence ISA 2C / (M) - Standard Complementar Informations Special Options w/ SO w/ SO Cable Cable CS-02 - RS232C - 5 m QTY Softwares QTY 1 PÇ e.tool ME3011b -view 1 PÇ Return to Manual Manual ME3011b_E_v0707_Pre.doc 13/50

14 FRONT DISPLAY INSCRIPTIONS 1 Low Relief Engraving 1.1 Back Light Display LB 24 x 48 White Translucent - Code: Character height = 3 mm Maximum number of characters per line = 19 Maximum number of lines = ABCDEFGHJKLMNOPRSTU ABCDEFGHJKLM ABCDEFGH EFGH ABCDEFGHJKLMNOPRSTU ABCDEFGHJKLM ABCDEFGH 5, LED Display MK 24 x 48 - RAL 7032 color - Code: Character height = 3 mm Maximum number of characters per line = 15 Maximum number of lines = 4 23,5 24 ABCDEFGHJKLMNOP ABCDEFGH ABCDEFGHJKLMNOP ABCDEFGH ,5 24 ABCDEFGHJKLMNOP ABCDEFGH ABCDEFGHJKLMNOP , ,5 48 Manual ME3011b_E_v0707_Pre.doc 14/50

15 SIGNALING SEQUENCES The ME 3011 can be configured in order to comply with 16 signaling sequence. Among them the most important are the following: ISA-RP 18.1/(ISA-S18.1): ISA1/(A), ISA-1A/(A-5), ISA-1B/(A-4), ISA-2A/(R-8), ISA-2C/(M), ISA-4A/(F1A), ISA-4AR/(F1M) etc. Other sequences can be implemented on request. ALARM SEQUENCE REF ISA ALARM NORMAL ABNORMAL BACK TO ACKNOWLEDGE ACKNOWLEDGE BACK TO NORMAL NORMAL BEFORE SOUND LIGHT ACKNOWL. SOUND LIGHT RESET ISA 1 (A) Light Sound ISA 1A (A-5) Light Sound ISA 1B (A-4) ISA 2A (R-8) ISA 2C (M) (default) Light Sound Light Sound Light Sound F F S F F S PRIMARY ALARM SEQUENCE (1st. EVENT) REF ISA ALARM NORMAL ABNORMAL ACKNOWLEDGE BACK TO NORMAL BACK TO NORMAL BEFORE ACKNOWL. ACKNOWLEDGE INITIAL SUBSEQ. INITIAL SUBSEQ. INITIAL SUBSEQ. INITIAL SUBSEQ. INITIAL SUBSEQ. RESET ISA 4A (F1A) ISA 4R (F1M) Light Sound Light Sound LEGEND F Fast Led off Buzzer off S Slow Led on Buzzer on Led intermittent Manual ME3011b_E_v0707_Pre.doc 15/50

16 SPECIAL OPTIONS 1 Light display with more than one color In this case, the quantity and position for each color must be request by the costumer. For LED Display up to 3 colors (red / yellow / green) For Back Light Display up to 5 colors (red / yellow / green / white / blue) 2 - Back Light Socket In this option, the SMD Led is socket mounted and plugged on the annunciators PCB. It allows changing the indicating light color for the individual alarm points. The socket BL must be specified at ordering the annunciator, as a special factory option. Manual ME3011b_E_v0707_Pre.doc 16/50

17 PRODUCT DESCRIPTION - CM-0x MODULES 1 - CM-0x - Central Module - Master CPU Module with 4 alarm points Master CPU module is responsible for slave module management, man-machine interface for alarm acknowledge, annunciator configuration, sound signaling, light signaling and its own operating status. Annunciator has a RS 485 interface with Modbus RTU protocol as option, allowing interconnection of several annunciator assemblies, as well as PLC s, RUT s and supervisory software. Each microcontroller keeps input status stored under its processing and annunciator configuration, allowing to retrieve the operational situation in case of a power failure. Master CPU is able to control up to 60 alarm points and up to 3 Slave CPUs directly, covering a total of 252 points; communication among them is performed serially, through a two-way internal bus, in compliance with asynchronous standard. Equipment configuration is made through 5 buttons on CPUs keyboard or via the e.tool ME3011 config software. Central Module with arrangement 2v x 4h Central Module with arrangement 2v x 4h CM-04 Central Module with arrangement 4v x 2h 1.1 PRODUCT DESCRIPTION - MODULE Vdc Fault Vac Fault b RS 485 balancing: Front view Extract the tile of alarm point number 3 and set the jumpers as follows: JP1 and JP2 closed for the last annunciator on the network. JP1 and JP2 open for all intermediary annunciators on the network. Note: Rear view OPTIONS The Modbus cable shield must be grounded. Manual ME3011b_E_v0707_Pre.doc 17/50

18 1.2 PRODUCT DESCRIPTION - CM-04 MODULE Vdc Fault RS 485 balancing: Extract the tile of alarm point number 3 and set the jumpers as follows: JP1 and JP2 closed for the last annunciator on the network. JP1 and JP2 open for all intermediary annunciators on the network. Vac Fault b Front view Note: The Modbus cable shield must be grounded. OPTIONS Rear view Manual ME3011b_E_v0707_Pre.doc 18/50

19 PRODUCT DESCRIPTION - CM-0x MODULES and CM-04 Module Connector Identification Line CM-04 X11 X11 X12 Connector Term. Desc. Function 1 Vac Vac Power Supply X11 - CX1-1 X11 - CX1-1 2 Vac Vac Power Supply X11 - CX1-2 X11 - CX1-2 CX1 3 Shield Shield X11 - CX1-3 X11 - CX Vdc + Vdc Power Supply X11 - CX1-4 X11 - CX Vdc - Vdc Power Supply X11 - CX1-5 X11 - CX1-5 CX2 1 V + 24 Vdc X11 - CX2-1 X11 - CX2-1 Auxiliary Field Output 2 OUT Vdc X11 - CX2-2 X11 - CX2-2 1 SLM Sleep Mode X11 - CX3-1 X11 - CX3-1 2 HA (QS) Sound Acknowladge X11 - CX3-2 X11 - CX3-2 CX3 3 LA (QL) Light Acknowladge X11 - CX3-3 X11 - CX3-3 4 RE Reset X11 - CX3-4 X11 - CX3-4 5 LT/FT Light Test/Fubctional Test X11 - CX3-5 X11 - CX3-5 6 KSLM Keyboard Sleep Mode X11 - CX3-6 X11 - CX3-6 CX4 CX5 CX6 1 X11 - CX4-1 X11 - CX4-1 Relay RCX4 [1] Potential-free contact 2 X11 - CX4-2 X11 - CX4-2 1 X11 - CX6-1 X11 - CX6-1 Relay RCX6 [3] Potential-free contact 2 X11 - CX6-2 X11 - CX6-2 1 Relay RCX5 [2] Potential-free contact X11 - CX5-1 X11 - CX5-1 2 X11 - CX5-2 X11 - CX5-2 CX INTERF. RS232C Serial Interface RS232C X11 - CX7 - IS X11 - CX7 - IS CX8 CX9 1 1 Data + INTERF. SINC RS 485 Interface SincOut X11 - CX8-1 GPS syncrhonization and/or Flashing X12 - CX8-1 X11 - CX9-1 X12 - CX Data - (3) SincIn/GPS X11 - CX8-2 synchonization X12 - CX8-2 X11 - CX9-2 X12 - CX9-2 1 Input + Alarm Input 1 X11 - C1-1 X12 - C1-1 2 Input + Alarm Input 2 X11 - C1-2 X12 - C1-2 C1 3 Alarm Inputs Input + Alarm Input 3 X11 - C1-3 X12 - C1-3 4 Input + Alarm Input 4 X11 - C1-4 X12 - C1-4 5 Common - Alarm Input Common (-) X11 - C1-5 X12 - C1-5 1 Relay Input 1 repeat relay (+) X11 - C2-1 X12 - C2-1 2 Relay Input 2 repeat relay (+) X11 - C2-2 X12 - C2-2 C2 3 RRO (4) Relay Input 3 repeat relay (+) X11 - C2-3 X12 - C2-3 4 Relay Input 4 repeat relay (+) X11 - C2-4 X12 - C2-4 5 (+) CV Contact Voltage for all repeater relays(+) X11 - C2-5 X12 - C2-5 C3 1 PSFD Relay Vdc Fault repeat relay (+) X11 - C3-1 X12 - C3-1 2 (5) Relay Vac Fault repeat relay (+) X11 - C3-2 X12 - C3-2 Power Supply (1) Remote Push-Button (24Vdc) Programable Relays (2) Identification CM-04 (1) As standard, only 24 Vdc, other voltages must be specified at order (2) As standard, CX4 for external Buzzer Option, when CX9 is used for GPS synchronism, the flashing (3) synchronization is performed internaly. (4) Option (5) Option, the selection is performed at the power supply specification Manual ME3011b_E_v0707_Pre.doc 19/50

20 2 - SM-02 - Slave Module - CPU Slave Module with 8 alarm points Each Slave CPU Module is able to control up to 64 alarm points, and is used if number of alarm points exceeds 60. For configurations from 62 to 128 points one Slave CPU Module is used, from 130 to 188 two Modules, and from 190 to 252 three Modules. Front view OPTIONS SM-02 Module Connector Identification Line Connector Term. Den. Function Identificacion X.. CX1 CX2 C1 C2 1 Vac Vac Power Supply X.. - CX1-1 2 Vac Vac Power Supply X.. - CX1-2 3 NC Not Connected 4 + Vdc + Vdc Power Supply X.. - CX Vdc - Vdc Power Supply X.. - CX Vdc X.. - CX2-1 Auxiliary Field Output 2-24 Vdc X.. - CX2-2 1 Input + Alarm Input 1 X.. - C1-1 2 Input + Alarm Input 2 X.. - C1-2 3 Input + Alarm Input 3 X.. - C1-3 4 Input + Alarm Input 4 X.. - C1-4 5 Input + Alarm Input 5 X.. - C1-5 6 Input + Alarm Input 6 X.. - C1 6 7 Input + Alarm Input 7 X.. - C1 7 8 Input + Alarm Input 8 X.. - C1 8 9 Common - Alarm Input Common (-) X.. - C1 9 1 Relay Input 1 repeat relay (+) X.. - C2-1 2 Relay Input 2 repeat relay (+) X.. - C2-2 3 Relay Input 3 repeat relay (+) X.. - C2-3 4 Relay Input 4 repeat relay (+) X.. - C2-4 5 Relay Input 5 repeat relay (+) X.. - C2-5 6 Relay Input 6 repeat relay (+) X.. - C2 6 7 Relay Input 7 repeat relay (+) X.. - C2 7 8 Relay Input 8 repeat relay (+) X.. - C2 8 9 (+) CV Contact Voltage for all repeater relays(+) X.. - C2 9 Power Supply IN (1) OUT Alarm Inputs RRO (2) (1) (2) The power supply for the Slave Module SM-02 must be the same as for the CM-0x module, otherwise, the alarm annunciator can be damaged. Option Manual ME3011b_E_v0707_Pre.doc 20/50

21 PRODUCT DESCRIPTION - EM-0x EXPANSION MODULES 3 - EM-0x - Expansion Module EM-02 - Expansion Module with 8 alarm points, arrangement 2v x 4h. Each expansion modules provides 8 alarm points, used together with CPUs. Front view OPTIONS Rear view EM-02 - Expansionn Module Connectors Identification Line Connector Term. Des. Function Identificacion X.. C1 C2 1 Input + Alarm Input 1 X.. - C1-1 2 Input + Alarm Input 2 X.. - C1-2 3 Input + Alarm Input 3 X.. - C1-3 RRO (1) Alarm Inpurs 4 Input + Alarm Input 4 X.. - C1-4 5 Input + Alarm Input 5 X.. - C1-5 6 Input + Alarm Input 6 X.. - C1-6 7 Input + Alarm Input 7 X.. - C1-7 8 Input + Alarm Input 8 X.. - C1-8 9 Common - Alarm Input Common (-) X.. - C1-9 1 Relay Input 1 repeat relay (+) X.. - C2-1 2 Relay Input 2 repeat relay (+) X.. - C2-2 3 Relay Input 3 repeat relay (+) X.. - C2-3 4 Relay Input 4 repeat relay (+) X.. - C2-4 5 Relay Input 5 repeat relay (+) X.. - C2-5 6 Relay Input 6 repeat relay (+) X.. - C2-6 7 Relay Input 7 repeat relay (+) X.. - C2-7 8 Relay Input 8 repeat relay (+) X.. - C2-8 9 (+) CV Contact Voltage for all repeater relays(+) X.. - C2-9 (1) Option Manual ME3011b_E_v0707_Pre.doc 21/50

22 PRODUCT DESCRIPTION - EM-0x EXPANSION MODULES EM-03 Expansion Module with 8 alarm points, arrangement 4v x 2h Front view OPTIONS Rear view EM-03 - Expansion Module Connectors Identification Line Connector Term. Obs. Function Identificacion X.. X..+1 C1 C2 C3 C4 1 Input + Alarm Input 1 X.. - C1-1 2 Input + Alarm Input 2 X.. - C1-2 3 Input + Alarm Input 3 X.. - C1-3 4 Input + Alarm Input 4 X.. - C1-4 5 Common - Alarm Input Common (-) X.. - C1-5 1 Relay Input 1 repeat relay (+) X.. - C2-1 2 Relay Input 2 repeat relay (+) X.. - C2-2 3 Relay Input 3 repeat relay (+) X.. - C2-3 4 Relay Input 4 repeat relay (+) X.. - C2-4 5 (+) CV Contact Voltage for 4 repeaters 1 to 4 (+) X.. - C2-5 1 Input + Alarm Input 5 X.. - C3-1 2 Input + Alarm Input 6 X.. - C3-2 3 Input + Alarm Input 7 X.. - C3-3 4 Input + Alarm Input 8 X.. - C3-4 5 Common - Alarm Input Common (-) X.. - C3-5 1 Relay Input 5 repeat relay (+) X.. - C4-1 2 Relay Input 6 repeat relay (+) X.. - C4-2 3 Relay Input 7 repeat relay (+) X.. - C4-3 4 Relay Input 8 repeat relay (+) X.. - C4-4 5 (+) CV Contact Voltage for 4 repeaters 5 to 8 (+) X.. - C4-5 Alarm Inputs 1-4 RRO 1-4 (1) Alarm Inputs 5-8 RRO (1) 5-8 (1) Option Manual ME3011b_E_v0707_Pre.doc 22/50

23 PRODUCT DESCRIPTION - EM-0x EXPANSION MODULES 3.3- EM-04 Expansion Module with 4 alarm points, arrangement 2v x 2h OPTIONS EM-04 - Expansion Module Connectors Identification Line Connector Term. Obs. Function Identificacion X.. C1 C2 1 Input + Alarm Input 1 X.. - C1-1 RRO (1) Alarm Inputs 2 Input + Alarm Input 2 X.. - C1-2 3 Input + Alarm Input 3 X.. - C1-3 4 Input + Alarm Input 4 X.. - C1-4 5 Common - Alarm Input Common (-) X.. - C1-5 1 Relay Input 1 repeat relay (+) X.. - C2-1 2 Relay Input 2 repeat relay (+) X.. - C2-2 3 Relay Input 3 repeat relay (+) X.. - C2-3 4 Relay Input 4 repeat relay (+) X.. C2-4 5 (+) CV Contact Voltage for this 4 repeater relays(+) X.. - C2-5 (1) Option Manual ME3011b_E_v0707_Pre.doc 23/50

24 KEYBOARD FUNCTION DESCRIPTION 1 Keyboard Functions FA Red LED on, indicates system failure RUN Green LED continuously on indicates system operative Blinking Green LED indicates system operative in Sleep Mode (SLM) Vdc Fault Vac Fault b PSFD Yellow LED for Vdc power supply fault and Orange LED for Vac power supply fault indication, if requested. Enter Used only in keyboard configuration mode. HA Sound acknowledge LA Light acknowledge RE Reset LT/FT Light Test or Functional Test, selectable via configuration modes. 1.1 Horn/Buzzer Acknowledge (HA) Sound Acknowledge is performed through CPU front button. Its activation stops the buzzer. 1.2 Light Acknowledge (LA) Light acknowledge is performed through CPU front button, which makes intermittent light signaling (blinking) turn permanently on or off when activated, depending on selected sequence. Note About Sound and Light Acknowledge: Sound and Light Acknowledge functions can be activated manually, as described above, or automatically, with adjustable time periods from 5 s to 45 hours. Sound and light acknowledge buttons can be configured for simultaneous activation or in a way to interlock them, i.e., light acknowledge function is only accepted after acknowledging sound. See details on annunciator configuration chapter Reset (RE) Reset sequence is performed through CPU module, which resets alarm sequence when activated. Depending on selected sequence, Reset button is disabled. 1.4 Light Test (LT) Light test is performed through button on CPU module front panel, which turns all equipment LED s on when activated. Manual ME3011b_E_v0707_Pre.doc 24/50

25 1.5 Functional Test (FT) KEYBOARD FUNCTION DESCRIPTION Functional test is performed through TL button on CPU module front panel, which simulates an alarm condition in all points when activated, according to pre-configured sequence in equipment. Note About Light and Functional Tests: Light test button (TL) must be configured according to desired Function: either Light test, or Function test. See details on annunciator configuration chapter Enter The enter is button is used to reset the annunciator and for configuration via keyboard RUN Led Green Led continuously ON indicates that the system is operative. Green Led blinking indicates that the system is operative in sleep mode (SLM) 1.8 FA Led Red Led blinking in other sequence that the alarm windows, means that the annunciator is faulty, for this function the buzzer signalization is programmable. The internal fault detected are: Watsh dog Communication between Master and Slave CPUs Live Signal 1.9 PSFD The Power Supply Fail detection is improved via Firmware and the voltage value to be detected must be informed at the annunciators order., for Vdc and/or Vac. There are two ways to visualize these indication: Standard: o Vdc Fault is indicated at the keyboard yellow led o Vac Fault is indicated at the keyboard orange led Option: o Vdc Fault is indicated at the alarm point 2 window o Vac Fault is indicated at the alarm point 4 window Manual ME3011b_E_v0707_Pre.doc 25/50

26 GENERAL FUNCTION DESCRIPTION 2 General functions 2.1 Sound Signal Annunciator has a buzzer, which can be configured to generate different sounds (continuous, intermittent and two-tone) and disabled. For connecting external buzzer, potential-free terminals are available on the rear panel for external buzzer, with 30W of capacity. 2.2 Alarm Group Alarm group function is used to group inputs in certain combinations for a better operating visualization. Thus, a certain alarm group can have its light indication in a different color from the rest of annunciator and a differentiated sound signaling. Annunciator has 3 relays, which can be programmed to activate if an alarm occurs in up to 3 alarm groups Sleep Mode - SLM Sleep Mode function is used to deactivate internal light and/or sound signaling. When active, front panel RUN led (Green) starts blinking, indicating that device is operative in sleep mode. This Function can be enabled/disabled through front buttons or external button. 2.4 Input Temporization Inputs have filters with individually adjustable times from 5 ms to 600 ms. 2.5 Automatic Storage of Last Status of Annunciator CPU module will store the last status of equipment in case of power failure, retrieving this data when power returns. 2.6 Flashing Light signaling has two flashing frequencies: fast flashing = 1.2 Hz and slow flashing = 0.4 Hz 2.7 Keyboard OFF Allows turn off the annunciators keybord trough an external key, maintaining the keyboard functions only at the remote push-button station. Manual ME3011b_E_v0707_Pre.doc 26/50

27 INSTALLATION ANNUNCIATOR POWER SUPPLY 1 ME3011b power supply 1.1 Annunciator standard supply voltage is 24 Vdc For other voltages, the following power supplies can be incorporated into the annunciator: 2 Redundant voltage supply with 19 to 264 Vdc and/or 90 to 264 Vac The quantity is the same as of Master and Slave CPUs used in annunciator configuration. 2.1 Vac power supply The fuses must be dimensioned according the consumption table In case with supply only with one phase, only one fuse is needed 2.2 Vdc power supply It is advisable to use fast fuse at terminal 4 (+) The fuses must be dimensioned according the consumption table at page 26. Note: For annunciators with more than 60 points, the power supply of the Slave Module(s) SM-02 must be the same as the Central Module, otherwise, the annunciator can be damaged. Manual ME3011b_E_v0707_Pre.doc 27/50

28 INSTALLATION - INPUTS 1 Field Inputs Field inputs are galvanically isolated by opto couplers and protected against surges, with a common signal per alarm group (4 points for Cm-0x Module, 8 points for EM-02, EM-03 and SM-02, 4 points for EM-04), and can be provided optionally with repeat relays. As option, inputs can be isolated each other and, in this case, the field signal input terminal is not relevant. Each Input had one individual filter, and can be configured from 5 ms to 600 ms, in steps of 2.5 ms via keyboard, or via software e.tool ME3011 config. The field voltage are indicated at the product label 2 Remote Push-Button Station The central Modules CM-0x have a opto isolated terminal block (CX3) to connect following functions to a remote push-button station: 1. Sleep Mode 2. Sound Acknowledge 3. Light Acknowledge 4. Reset 5. Light Test/Functional Test 6. Keyboard OFF Mode Functions on terminals 1, 2, 3 and 5 are programmable via e.tool ME3011b- config or Keyboard, according necessity. Terminal 6 (KSLM) is only a hardware switch, to turn off the Keyboard push-buttons. Manual ME3011b_E_v0707_Pre.doc 28/50

29 INSTALLATION - INPUTS 3 GPS synchronization (Option) Via connector CX9 from the CM-0x CPUs In this case, the blink synchronism is performed internally via Modbus. Manual ME3011b_E_v0707_Pre.doc 29/50

30 INSTALLATION - OUTPUTS 3 Field Voltage Supply 24 Vdc Annunciator has, regardless main voltage supply or field voltage, one 24 Vdc / 1A output for field contacts in CM-0x and SM-02 modules. It is recommended the use of a fast 1A fuse at +24Vdc 4 External Buzzer Relay with 1 potential-free NO contact, in CM-0x modules. As standard, the relay on terminals CX4 is used for the external buzzer. 5 Programmable relays outputs Annunciator provides 3 potential-free contacts for other functions, such as: external buzzer, alarm group, triggering a second buzzer, etc. F1 Correspondent connectors: CX4, CX5 and CX6. Manual ME3011b_E_v0707_Pre.doc 30/50

31 INSTALLATION - OUTPUTS 6 Repeater Relays output (Option) Relay with 1 potential-free NO contact per alarm input, where the relays coil is actuated due the input voltage. That means, if the annunciator fail, the alarms continues to be repeated. For field voltages over 125Vdc and Vac voltages, this option is not available. ME3011b relays capacity Manual ME3011b_E_v0707_Pre.doc 31/50

32 7 Repeater relays for power fault detection (Option) The Vdc fault detection can be indicated at the alarm point 2 or at the yellow led from the keyboard. The Vac fault detection can be indicated at the alarm point 4 or at the orange led from the keyboard. If the PSFD indication are the alarm points 2 and 4, there are no relay on the connector C2-2 and C2-4. The nominal voltages to be detected and the indication position must be defined at the product order. Manual ME3011b_E_v0707_Pre.doc 32/50

33 INSTALLATION - OUTPUTS 8 Flashing Synchronization Option This function is performed due the CPUs CM-0x CX9 connector. The tcx9 terminal 1 of the synchronizing annunciator must be connected to the CX9-terminal 1 from the other annunciators. The CX2 terminal 2 (-24Vdc) from all annunciators must be connected. Manual ME3011b_E_v0707_Pre.doc 33/50

34 RECOMMENDATIONS Recommendations: Control and load cables must be ad equally separated, if possible in separated cable trays. If there are crossing lines, try to mount it on perpendicular crossing. It is recommended that power line filters be installed at the cabinet input to achieving successful filtering of electromagnetic interference, this filter acts as a barrier between polluted energy and clean energy goes into the cabinet. The filter must be connected to an effective ground plane and where proximity does not couple radiated noise to the clean lines. POWER CONSUMPTION Nr. of Points X Power Consumption (W) Annunciators without repeater relays (RRO) Annunciators with repeater relays (RRO) Points 24Vdc 48Vdc 60Vdc 125Vdc 127Vac 220Vac Points 24Vdc 48Vdc 60Vdc 125Vdc 4 1,9 3,3 4,1 3,9 3,9 6,8 4 2,7 4,1 4,9 6,3 12 3,7 5,5 5,7 9,1 7,9 11,5 12 6,1 7,8 8,2 16,4 20 5,6 7,2 8,0 11,8 11,9 16,3 20 9,6 11,1 12,1 23,9 28 7,4 9,4 10,2 15,7 14,7 23, ,0 14,9 16,0 32,7 36 9,2 11,1 11,8 19,7 18,7 28, ,4 18,2 19,2 41, ,0 12,9 14,0 23,6 22,7 34, ,8 21,5 23,1 50, ,9 14,6 16,2 27,6 26,7 39, ,3 24,8 27,0 59, ,5 16,3 17,9 31,5 29,5 46, ,5 28,1 30,3 68,0 Manual ME3011b_E_v0707_Pre.doc 34/50

35 INPUT LEVELS Manual ME3011b_E_v0707_Pre.doc 35/50

36 CONNECTION DIAGRAM EXAMPLES 1 Standard, Front view I - X25-C1-1 I - X25-C1-2 I - X25-C1-3 I - X25-C1-4 I - X15-C1-1 I - X15-C1-2 I - X15-C1-3 I - X15-C1-4 Connector Identification I - X..-C_-N I - X25-C1-5 I - X25-C1-6 I - X25-C1-7 I - X25-C1-8 I - X15-C1-5 I - X15-C1-6 I - X15-C1-7 I - X15-C1-8 I - Alarm Input I - X24-C1-1 I - X24-C1-2 I - X24-C1-3 I - X24-C1-4 I - X14-C1-1 I - X14-C1-2 I - X14-C1-3 I - X14-C1-4 X.. - Connector line I - X24-C1-5 I - X24-C1-6 I - X24-C1-7 I - X24-C1-8 I - X14-C1-5 I - X14-C1-6 I - X14-C1-7 I - X14-C1-8 C_ - Connector I - X23-C1-1 I - X23-C1-2 I - X23-C1-3 I - X23-C1-4 I - X13-C1-1 I - X13-C1-2 I - X13-C1-3 I - X13-C1-4 N - Connector terminal cooresponding to the Alarm Point I - X23-C1-5 I - X23-C1-6 I - X23-C1-7 I - X23-C1-8 I - X13-C1-5 I - X13-C1-6 I - X13-C1-7 I - X13-C1-8 I - X22-C1-1 I - X22-C1-2 I - X22-C1-3 I - X22-C1-4 I - X12-C1-1 I - X12-C1-2 I - X12-C1-3 I - X12-C1-4 I - X22-C1-5 I - X22-C1-6 I - X22-C1-7 I - X22-C1-8 I - X12-C1-5 I - X12-C1-6 I - X12-C1-7 I - X12-C1-8 I - X21-C1-1 I - X21-C1-2 I - X21-C1-3 I - X21-C1-4 I - X11-C1-1 I - X11-C1-2 I - X21-C1-5 I - X21-C1-6 I - X21-C1-7 I - X21-C1-8 I - X11-C1-3 I - X11-C1-4 Manual ME3011b_E_v0707_Pre.doc 36/50

37 2 Standard, rear view CONNECTION DIAGRAM EXAMPLES Manual ME3011b_E_v0707_Pre.doc 37/50

38 2 - Connection diagram with RRO and power fault indication, Vdc at alarm point 2 or yellow led on the keyboard end/or Vac fault at alarm point 4 or orange led on the keyboard Front view CONNECTION DIAGRAM EXAMPLES Connector Identification I1- X25-C1-1 R1 - X25-C2-1 I2 - X25-C1-2 R2 - X25-C2-2 I3 - X25-C1-3 R3 - X25-C2-3 I4- X25-C1-4 R4 - X25-C2-4 I1- X15-C1-1 R1 - X15-C2-1 I2 - X15-C1-2 R2 - X15-C2-2 I3 - X15-C1-3 R3 - X15-C2-3 I4- X15-C1-4 R4 - X15-C2-4 IN - X..-C_-N I5 - X25-C1-5 R5 - X25-C2-5 I6 - X25-C1-6 R6 - X25-C2-6 I7 - X25-C1-7 R7 - X25-C2-7 I8 - X25-C1-8 R8 - X25-C2-8 I5 - X15-C1-5 R5 - X15-C2-5 I6 - X15-C1-6 R6 - X15-C2-6 I7 - X15-C1-7 R7 - X15-C2-7 I8 - X15-C1-8 R8 - X15-C2-8 I - Alarm Input I1- X24-C1-1 R1 - X24-C2-1 I2 - X24-C1-2 R2 - X24-C2-2 I3 - X24-C1-3 R3 - X24-C2-3 I4- X24-C1-4 R4 - X24-C2-4 I1- X14-C1-1 R1 - X14-C2-1 I2 - X14-C1-2 R2 - X14-C2-2 I3 - X14-C1-3 R3 - X14-C2-3 I4- X14-C1-4 R4 - X14-C2-4 R - Alarm repeater relay (RRO) I5 - X24-C1-5 R5 - X24-C2-5 I6 - X24-C1-6 R6 - X24-C2-6 I7 - X24-C1-7 R7 - X24-C2-7 I8 - X24-C1-8 R8 - X24-C2-8 I5 - X14-C1-5 R5 - X14-C2-5 I6 - X14-C1-6 R6 - X14-C2-6 I7 - X14-C1-7 R7 - X14-C2-7 I8 - X14-C1-8 R8 - X14-C2-8 X.. - Connector line I1- X23-C1-1 R1 - X23-C2-1 I2 - X23-C1-2 R2 - X23-C2-2 I3 - X23-C1-3 R3 - X23-C2-3 I4- X23-C1-4 R4 - X23-C2-4 I1- X13-C1-1 R1 - X13-C2-1 I2 - X13-C1-2 R2 - X13-C2-2 I3 - X13-C1-3 R3 - X13-C2-3 I4- X13-C1-4 R4 - X13-C2-4 C - Connector I5 - X23-C1-5 R5 - X23-C2-5 I6 - X23-C1-6 R6 - X23-C2-6 I7 - X23-C1-7 R7 - X23-C2-7 I8 - X23-C1-8 R8 - X23-C2-8 I5 - X13-C1-5 R5 - X13-C2-5 I6 - X13-C1-6 R6 - X13-C2-6 I7 - X13-C1-7 R7 - X13-C2-7 I8 - X13-C1-8 R8 - X13-C2-8 N - Connector terminal cooresponding to the Alarm Point I1- X22-C1-1 R1 - X22-C2-1 I2 - X22-C1-2 R2 - X22-C2-2 I3 - X22-C1-3 R3 - X22-C2-3 I4- X22-C1-4 R4 - X22-C2-4 I1- X12-C1-1 R1 - X12-C2-1 I2 - X12-C1-2 R2 - X12-C2-2 I3 - X12-C1-3 R3 - X12-C2-3 I4- X12-C1-4 R4 - X12-C2-4 I5 - X22-C1-5 R5 - X22-C2-5 I6 - X22-C1-6 R6 - X22-C2-6 I7 - X22-C1-7 R7 - X22-C2-7 I8 - X22-C1-8 R8 - X22-C2-8 I5 - X12-C1-5 R5 - X12-C2-5 I6 - X12-C1-6 R6 - X12-C2-6 I7 - X12-C1-7 R7 - X12-C2-7 I8 - X12-C1-8 R8 - X12-C2-8 I1- X21-C1-1 R1 - X21-C2-1 I5 - X21-C1-5 R5 - X21-C2-5 I2 - X21-C1-2 R2 - X21-C2-2 I6 - X21-C1-6 R6 - X21-C2-6 I3 - X21-C1-3 R3 - X21-C2-3 I7 - X21-C1-7 R7 - X21-C2-7 I4- X21-C1-4 R4 - X21-C2-4 I8 - X21-C1-8 R8 - X21-C2-8 I1- X11-C1-1 R1 - X11-C2-1 I3 - X11-C1-3 R3 - X11-C2-3 I2 - X11-C1-2 R2 - X11-C2-1 Vdc Fault (*) RD - X11-C3-2(*) I4 - X11-C1-4 R4 - X11-C2-4 Vac Fault (*) RA - X11-C3-1(*) Vdc Fault Vac Fault (*)If the Alarm points 2 an 4 are used for Power Suply Fault detector, the correspondent repeaters are on connector C3 repeaters Manual ME3011b_E_v0707_Pre.doc 38/50

39 CONNECTION DIAGRAM EXAMPLES Rear view Manual ME3011b_E_v0707_Pre.doc 39/50

40 TERMINAL IDENTIFICATION FOR ENCLOSURES WITH MODULE REAR VIEW Number of horizontal points (h) y = X1C X2C y = X1B X2B y = X1A X2A X3A y = X X X Number of vertical modules y = 8 y = 7 y = 6 y = X X X X X X X X X X X X X X X X Number of vertical points (v) y = X X X X y = X X X X y = X X X X y = 1 X X X X Number of horizontal modules Manual ME3011b_E_v0707_Pre.doc 40/50

41 TERMINAL IDENTIFICATION FOR ENCLOSURES WITH MODULE FRONT VIEW Number of horizontal points (h) y = X2C X1C y = X2B X1B y = X2A X2A X1A y = X X X Number of vertical Modules y = 8 y = 7 y = 6 y = X X X X X X X X X X X X X X X X Number of vertical Points (v) y = X X X X y = X X X X y = X X X X y = X X X X Number of horizontal Modules Manual ME3011b_E_v0707_Pre.doc 41/50

42 TERMINAL IDENTIFICATION FOR ENCLOSURES WITH CM-04 MODULE REAR VIEW Number of horizontal Points y = 12 6 X y = 11 2 X y = 10 6 X y = 9 2 X Number of vertical Modules y = 8 y = 7 y = 6 y = 5 6 X X X X X Number of vertical Points (v) y = 4 6 X X y = 3 2 X X X y = 2 2 X X X X y = 1 X11 CM X X X ,5 1,5 2,5 3,5 Number of horizontal Modules Manual ME3011b_E_v0707_Pre.doc 42/50

43 TERMINAL IDENTIFICATION FOR ENCLOSURES WITH CM-04 MODULE FRONT VIEW Number of horizontal Points y = 12 5 X y = 11 1 X y = 10 5 X y = 9 1 X Number of vertical Modules y = 8 y = 7 y = 6 y = 5 5 X X X X X Number of vertical Points (v) y = X X y = X X X y = X X X X y = X X X X CM ,5 2,5 1,5 0,5 Number of horizontal Modules Manual ME3011b_E_v0707_Pre.doc 43/50

44 NEW ARRANGEMENTS REAR VIEW 20v x 2h v x 2h EM EM-04 16v x 2h v x 2h EM EM EM EM-04 12v x 2h v x 2h EM EM EM EM EM EM-04 8v x 2h v x 2h EM-03 8 EM-03 8 EM-03 8 EM-03 8 EM-03 8 EM-03 8 EM-03 8 EM v x 2h CM-04 CM-04 CM-04 CM-04 CM-04 CM-04 CM-04 CM-04 CM-04 10v x 6h 8 4 4v x 6h 52 EM EM-04 8v x 6h EM EM EM v x 6h EM EM EM EM EM EM EM EM EM EM v x 6h EM EM EM EM-04 6v x 10h 4v x EM EM EM EM EM EM EM EM EM EM EM-03 2v x 10h 4v x 14h EM EM EM EM EM EM-04 2v x 14h EM EM EM EM EM EM-04 Manual ME3011b_E_v0707_Pre.doc 44/50

45 SM-02 MODULE POSITION ON 4h ENCLOSURE REAR VIEW 24v x 4h 8 92 EM-02 22v x 4h EM EM-02 20v x 4h EM EM EM SM SM SM v x 4h SM-02 16v x 4h EM EM EM EM EM-02 14v x 4h EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM v x 4h 8 44 EM-02 10v x 4h EM EM-02 8v x 4h EM EM EM-02 6v x 4h EM EM EM EM-02 4v x 4h EM EM EM EM EM-02 2v x 4h Manual ME3011b_E_v0707_Pre.doc 45/50

46 SM-02 MODULE POSITION ON 8h ENCLOSURE REAR VIEW 24v x 8h EM EM-02 22v x 8h EM EM EM EM-02 20v x 8h EM EM EM EM EM EM-02 18v x 8h SM EM SM EM SM EM SM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM SM EM SM EM SM EM SM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM-02 16v x 8h EM EM-02 14v x 8h EM EM EM EM-02 12v x 8h EM EM EM EM EM EM-02 10v x 8h SM EM SM EM SM EM SM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM-02 8v x 8h EM EM-02 6v x 8h EM EM EM EM-02 4v x 8h EM EM EM EM EM EM-02 2v x 8h EM EM EM EM-02 Manual ME3011b_E_v0707_Pre.doc 46/50

47 SM-02 MODULE POSITION ON 12h ENCLOSURE REAR VIEW 20v x 12h EM EM EM SM EM EM SM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM SM EM EM SM EM EM SM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM SM EM EM SM EM EM SM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM x 12h EM EM EM EM SM EM EM SM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM SM EM EM SM EM EM SM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM-02 8v x 12h EM EM EM-02 18v x 12h 12 x 12h 6v x 12h EM EM SM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM-02 SM x 12h 10 x 12h 4v x 12h Manual ME3011b_E_v0707_Pre.doc 47/50

48 SM-02 MODULE POSITION ON 16h ENCLOSURE REAR VIEW 16v x 16h EM EM EM EM-02 14v x 16h SM EM EM EM SM EM EM EM EM EM EM EM EM EM EM EM SM EM EM EM SM EM EM EM EM EM EM EM EM EM EM EM SM EM EM EM SM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM-02 12v x 16h EM EM EM EM-02 10v x 16h SM EM EM EM SM EM EM EM EM EM EM EM EM EM EM EM SM EM EM EM SM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM-02 8v x 16h EM EM EM EM SM EM EM EM SM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM-02 6v x 16h EM EM EM EM-02 4v x 16h EM EM EM EM EM EM-02 2v x 16h Manual ME3011b_E_v0707_Pre.doc 48/50

49 CONFIGURATION MODES The ME 3011b Annunciator provides two ways for parameter configuration. 1 Via Serial Interface By means of RS232C serial interface, using e.tool ME3011- config program. Detailed instructions you find at Configuration via serial interface - e.tool ME3011 config Manual Interface RS232C - Cable C S-02-5, 10 or 15m The latest e.tool ME3011- config software can be downloaded from our site: The manual of e.tool ME3011 config can be downloaded from our site: 3 Via KEYBOARD By means of central module, using buttons and LED s from keyboard in order to set programming phase and the 4 alarm LED s of central module for indicating selected parameter. NOTE: For detailed instructions for the keyboard configuration, please contact our service department: service@mauell.com.br COMMUNICATION PROTOCOL SERIAL MODBUS RTU (SLAVE) e.tool ME3011- view Visualization via serial interface Manual ME3011b_E_v0707_Pre.doc

50 Brazil Representatives and branches Worldwide Helmut Mauell do Brasil Est. Estadual Salvador de Leone, 2998 Abu Dhabi E.A.U. Korea Itapecerica da Serra - SP Argentina Malaysia Tel.: +55 (0) Belgium Netherlands Fax.: +55 (0) Czech Republic Norway Denmark Poland mauell@mauell.com.br Finland Singapore France Spain Great Britain Sweden Germany Hungary Switzerland Iran Turkey Helmut Mauell GmbH Kuwait USA Am Rosenhügel 1 7 D Velbert Tel.:+49 (0)20 53/1 30 Fax.:+49 (0)20 53/ info@mauell.com Manual ME3011b_E_v0707_Pre.doc

Alarm Systems. Digital Alarm Annunciator. ME 3011b Instruction Manual SERIAL PRODUCTS. Manual ME3011b_E_r07 at 1/68

Alarm Systems. Digital Alarm Annunciator. ME 3011b Instruction Manual SERIAL PRODUCTS. Manual ME3011b_E_r07 at 1/68 Alarm Systems SERIAL PRODUCTS Digital Alarm Annunciator ME 3011b Instruction Manual Manual ME3011b_E_r07 at 1/68 1 Information and Technical Data Introduction 4 Warranty 4 Installation 5 Operation Principles

More information

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

Standard Devices. Electronic Alarm Indication Systems. ME 3011b Standard Devices Electronic Alarm Indication Systems ME 3011b Before connecting and powering this device, please read carefully the manual, and refer to it whenever you have any doubts. This brochure is

More information

ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems

ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems Electronic Alarm Indication Systems ME 3011 compact Power Station Control Systems Power Distribution Control Systems Control Room Technology Automation Equipment 2 Table of Contents Contents Page System

More information

ME 3011C / Alarm Indication / Quick Reference Guide

ME 3011C / Alarm Indication / Quick Reference Guide Tables of Contents Page Application 1 Features 1 Important Safety Information! 2 Note to this Guide 2 Further Information 2 Device Variants 2 General Functions 3 Annunciator Sequences - ISA 18.1 3 Plan

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

AIS750 Series Alarm Annunciator

AIS750 Series Alarm Annunciator Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &

More information

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014) AIS750 Series Alarm Annunciator User Manual (Ver 23 / JUNE 2014) 3-350 John Street, Thornhill, tario L3T 5W6 Phone: 289 597 APEX (2739) Fax: 289 597 2200 Toll Free: 1 866 776 2943 Email: mail@annunciatorca

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with,,,, 0 and signal inputs Storage of the last state of inputs and sequence in the case

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

System 9000TS Sequence of Events Recorder

System 9000TS Sequence of Events Recorder System 000TS Sequence of Events Recorder ms Event Recorder and combined Annunciator Modular, rack mounting design expandable to over 000 inputs ms time stamping of events across the whole system Up to,000

More information

DRAFT 20 October 2014

DRAFT 20 October 2014 Technical data MTL process alarm equipment EPS rev 8 Programmable alarm annunciator Modular construction from 1 to 256 alarm channels Multi-redundant design so there is no single point of failure Choice

More information

RS485 MODBUS Module 8AI

RS485 MODBUS Module 8AI Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

Series 725 Programmable Alarm Annunciator

Series 725 Programmable Alarm Annunciator Series 725 Programmable Alarm Annunciar Multi-redundant design for greater reliability Modular construction from 1 256 alarm channels Multi-redundant design so there is no single point of failure Choice

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with 8, 16, 24, 32, 40 and 48 signal inputs Status retention of inputs and sequence in case

More information

4 & 8-POINT ANNUNCIATORS Instruction Manual

4 & 8-POINT ANNUNCIATORS Instruction Manual 4 & 8-POINT ANNUNCIATORS Instruction Manual 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal

More information

X11CA COMPUTER ANNUNCIATORS

X11CA COMPUTER ANNUNCIATORS S E R I E S XCA COMPUTER ANNUIATORS E N G I N E E R I N G C O M P A N Y The Ronan Series XCA Computer Annunciators are the latest generation of Ronan s state-of-the-art annunciators offered in window models.

More information

Model A2100 Series Annunciator

Model A2100 Series Annunciator Seekirk Model A2100 Series Annunciator Applications: For usage within transformers, switchgear, breakers and/or within any processing equipment or control room applications either attended or unattended

More information

CLEANROOM MONITOR CR3A Network - Installation Instructions

CLEANROOM MONITOR CR3A Network - Installation Instructions CLEANROOM MONITOR CR3A Network - Installation Instructions INTRODUCTION The CR3 Series Cleanroom Monitor, was developed specifically to allow for monitoring of confined spaces with accuracy and reliability.

More information

M1000 Alarm Annunciator

M1000 Alarm Annunciator Data Sheet Alarm Annunciator Reliable Supervision and Control 10 inputs with LED indications Supports both NO/NC input contacts 10 open collector outputs Built-in siren relay Text label for alarm descriptions

More information

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117 Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel Revision E 61117 CAUTION: (Read This First) This panel has been designed to make it nearly bullet proof to mistakes made when wiring

More information

AO Annunciator Module

AO Annunciator Module General Specifications GS48C43Z01-00E-N AO-543-01 Annunciator Module GENERAL Figure 1 This module has two independent annunciator circuits. The circuits handle fault signals and operator actions (acknowledge,

More information

Technical Manual. Level Alarm Unit CARLA & WIDS

Technical Manual. Level Alarm Unit CARLA & WIDS CARLA & WIDS Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual CARLA for Tankers Cargo Tanks

More information

MO n : 12JMC rév A

MO n : 12JMC rév A CTT8 MO n : rév A Page 2 / 18 MODIFICATIONS Rev. Description Date Checked by Approuved by Z Creation 2012/02/12 JMC LA A First issue 2012/02/14 JMC LA INDEX Page 3 / 18 GENERALITY 4 INTRODUCTION 4 ACCESSORIES

More information

FEC400 Series. Installation Manual

FEC400 Series. Installation Manual FEC400 Series Conventional microprocessor controlled fire detection and alarm panels with extinguishing control Installation Manual Version 2.3 / August 2004 Aritech is a GE Interlogix brand. http://www.geindustrial.com/ge-interlogix/emea

More information

Complex alarming made simple

Complex alarming made simple SEL-2523 Annunciator Panel Complex alarming made simple Superbright LEDs provide easily visible alarm indication in any lighting condition. Sequential Events Recorder (SER) data help identify the root

More information

P2267 NETWORK INTERFACE

P2267 NETWORK INTERFACE P2267 NETWORK INTERFACE USER MANUAL FOR OPERATING SYSTEMS: 22031-03 23636-01 October 2009 Associated Controls (Australia) Pty. Limited 2-4 Norfolk Road Greenacre, NSW, 2190. PH +61 2 9642 4922, FAX +61

More information

SIL725 Safety Annunciator

SIL725 Safety Annunciator SIL725 Safety Annunciar Configurable SIL2 Annunciar certified IEC61508 SIRA certified at safety integrity level SIL2 IEC61508 Modular construction from 1 128 alarm channels Multi-redundant design Choice

More information

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual PD154 & PD158 VIGILANTE II ANNUNCIATORS 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal Power

More information

System 9000TS Event Recorder

System 9000TS Event Recorder Important notes The 9000TS System described herein operates on a logic voltage of VDC and as standard +VDC is used for the field contact supply voltage. External power supplies using higher voltage ac/dc

More information

www. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application

www. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application Features Self-contained microprocessor-based annunciator unit with 64 alarm channels pplication larm channels activated by normally open or normally closed contact Small and large stand-alone annunciator

More information

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE General Description This guide provides a summary for installing and configuring the Centaur TM Cube Slave Alarm Signalling Equipment

More information

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

ICS Regent. Fire Detector Input Modules PD-6032 (T3419) ICS Regent Fire Detector Input Modules (T3419) Issue 1, March, 06 Fire detector input modules provide interfaces for 16 fire detector inputs such as smoke detectors, flame detectors, temperature detectors,

More information

725B Configuration Software Manual

725B Configuration Software Manual 725B Configuration Software Manual REV DATED DESCRIPTION AUTHOR APPROVED 0 09-03-10 First Issue P.Cartmell Page 1 of 80 SECTION 1 - SOFTWARE INSTALLATION... 5 725B ConfigurationSoftware Installation...

More information

Universal fault annunciator for panel mounting

Universal fault annunciator for panel mounting Universal fault annunciator for panel mounting Communication over Ethernet USM - Universal-fault annunciator for panel mounting Low depth housing for panel mounting Versions with 8, 16, 32 or 48 inputs

More information

FlashGuard 3000B Dual Lighting System Troubleshooting Guide

FlashGuard 3000B Dual Lighting System Troubleshooting Guide FlashGuard 3000B Dual Lighting System Troubleshooting Guide Table of Contents Section Flashhead (Strobe) Troubleshooting Flowchart 1 Multiple Strobe Troubleshooting Flowchart 2 Sidelight Troubleshooting

More information

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1- DPR-45 User Manual V-2.0 (2..206) DPR-45 TEMPERATURE PROTECTION RELAY PT00 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT 9-50VDC SUPPLY DESCRIPTION DPR-45 is a precision unit designed for the temperature

More information

CTT8 TEMPERATURE MONITOR DEVICE

CTT8 TEMPERATURE MONITOR DEVICE INSTRUCTION MANUAL IM302-U v2.3 CTT8 TEMPERATURE MONITOR DEVICE GENERALITY The device of control temperatures CTT8 is used in the control of electric machine, transformer, motor, etc. where it s possible

More information

Model A1700 Series Annunciator

Model A1700 Series Annunciator Seekirk Model A1700 Series Annunciator Applications: For usage in all types of process industries, electric generation, transmission and distribution, gas and water utilities. Features: The Seekirk model

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint

More information

Parameterisable compact fault annunciator with permanent display

Parameterisable compact fault annunciator with permanent display Parameterisable compact fault annunciator with permanent display FSM 10 Drop-flap fault annunciator 31.08.2010 Permanent display even on power failure Compact module for 10 alarms Supply and alarm signal

More information

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX Page 1 of 10 Model 10807800 January 2014 ACCURATE ELECTRONICS INC PO BOX 1654 97075-1654 8687 SW HALL BLVD 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 WWW.ACCURATE.ORG Practice Section 10807800

More information

Fire and Gas Monitoring Panel ST7-HV

Fire and Gas Monitoring Panel ST7-HV Fire and Gas Monitoring Panel ST7-HV INTRODUCTION TO THE ST7-HV SYSTEM The ST7-HV system is a programmable PLC suitable for safety and security installations with a high technological and economic content

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic

More information

On the job around the clock 24/7: Fire detection systems

On the job around the clock 24/7: Fire detection systems On the job around the clock 24/7: Fire detection systems Version 02.2010 Version: 02.2010 Product catalogue Fire detection systems This product catalogue is intended for sales purposes only. For planning,

More information

RTK 9000TS system. MTL sequence of events recorder. Technical data MTL process alarm equipment

RTK 9000TS system. MTL sequence of events recorder. Technical data MTL process alarm equipment Technical data MTL process alarm equipment EPS RTK 9000TS Rev RTK 9000TS system MTL sequence of events recorder Modular, rack mounting design expandable to over 900 inputs ms time stamping of events irrespective

More information

Window facia fault annunciators

Window facia fault annunciators Window facia fault annunciators WAP Window Annunciator Panel 15.08.2017 Annunciators for panel mounting with 24 signal inputs Storage of the last state of inputs and sequence in the case of power failure

More information

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670 Bulletin AV-670 Series 670 Hood Monitor Specifications - Installation and Operating Instructions DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Phone: 219/879-8000 Fax: 219/872-9057

More information

SACE PR021/K SIGNALLING UNIT

SACE PR021/K SIGNALLING UNIT SACE PR021/K SIGNALLING UNIT 1SDH000559R0002 L3016 1/52 EN CONTENTS 1. GENERAL INFORMATION...4 1.1. FOREWORD...4 1.2. APPLICABLE SCENARIOS...5 2. TECHNICAL SPECIFICATIONS...6 2.1. ELECTRICAL CHARACTERISTICS...6

More information

ACCURATE ELECTRONICS INC

ACCURATE ELECTRONICS INC ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A

More information

ESP TECHNOLOGIES LIMITED

ESP TECHNOLOGIES LIMITED Alarm Technology ESPAN-01 Series Annunciator System Combination type User Manual (Rev. 1) ESP TECHNOLOGIES LIMITED www.esptechno.com Content Page Introduction 2 General Description 2 Overview - Annunciator

More information

Fisher LCP100 Local Control Panel

Fisher LCP100 Local Control Panel Instruction Manual LCP100 Local Control Panel Fisher LCP100 Local Control Panel Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Installation... 3 Hazardous Area Classifications

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV LC1 & 2 Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV ZIRCONLC1 One Zone Conventional Fire Panel ZIRCONLC2 Two Zone Conventional Fire Panel Compliant with EN54-2:1998 & EN54-4:1998

More information

Annunciator Unit SACO 16 D1. Product Guide

Annunciator Unit SACO 16 D1. Product Guide Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally open

More information

THE SOLUTION. MSM-Product family OPERATING MANUAL. A fault annunciator of the. BSM Basic fault annunciator for panel mounting. INFOwww.ees-online.

THE SOLUTION. MSM-Product family OPERATING MANUAL. A fault annunciator of the. BSM Basic fault annunciator for panel mounting. INFOwww.ees-online. A fault annunciator of the MSM-Product family 17.07.2006 BSM Basic fault annunciator for panel mounting INFOwww.ees-online.de Contents overview 1 Validity 3 2 General notes 3 2.1 Used symbols 4 2.2 Used

More information

Annunciator unit. Application

Annunciator unit. Application Issued: April 1999 Status: April 1999 Version: B/09.11.2001 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally

More information

Installation / Monitoring Technique

Installation / Monitoring Technique Installation / Monitoring Technique INFOMSTER Common larm System, us Connection New- / First- /Common Signal nnunciator RP 5994, RP 5995 Replacements for: N 5969, N 5970, N 597 055005 Circuit Diagrams

More information

20 Light Remote Annunciator

20 Light Remote Annunciator Light Remote Annunciator Owner s Manual Surface Mount Flush Mount 94-95- Standard Annunciator 94-, 94-95-, 95-4- 4- Annunciator w/remote Relay Panel 4-, 4-4-, 4-49-, 49-49-, 49- Time Multiplexed Annunciator

More information

SCAN200E USER S MANUAL

SCAN200E USER S MANUAL SCAN200E USER S MANUAL Code No. 2071 1052 rev. 1.4 Code No. 2071 1052 Rev. 1.4 Page 2/16 SCAN200E User s Manual Foreword This manual is for SCAN200E Controller running software version 2.03 or later. We

More information

AN-3100D Annunciator

AN-3100D Annunciator AN-3100D Annunciator FOR POWER GENERATION, TRANSMISSION & DISTRIBUTION, PETROLEUM, PETROCHEMICAL, AND OTHER PROCESS INDUSTRIES INNOVATIVE ANNUNCIATOR Continuing with the widely successful AN-3100 series

More information

Instructions OJ EC-Controller (Translation of the original) BA-ESR_OJ-EC /2013

Instructions OJ EC-Controller (Translation of the original) BA-ESR_OJ-EC /2013 Instructions OJ EC-Controller (Translation of the original) EN BA-ESR_OJ-EC 1.0 02/2013 Contents Contents... 2 1. Revision Index... 2 2. Introduction... 3 3. Features... 4 4. Installation... 4 5. Operation...

More information

DMFPM-2R MULTIFUNCTIONAL

DMFPM-2R MULTIFUNCTIONAL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information

EXTINGUISHING AGENT RELEASE MODULE

EXTINGUISHING AGENT RELEASE MODULE EXTINGUISHING AGENT RELEASE MODULE Operation, Installation & Programming Manual Revision 3.00 Distributors For: 18-20 Brookhollow Ave telephone 02 8850 2888 www.firesense.com.au Baulkham Hills NSW 2153

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

ACTIVE INFRARED BARRIER

ACTIVE INFRARED BARRIER Although PROTECH provides high security indoor intrusion sensors for the military and government markets, our specialty is outdoor protection. Since we first introduced our PIRAMID outdoor dual technology

More information

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device Safety Instructions Used symbols Important Comments Before starting with installation of the MS 10B Alarm Unit, we recommend you to read the important information beneath. Qualification The installation

More information

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev. TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL Microener- Copyright 2010 FW 2.1 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

Annuciator Logic Controllers

Annuciator Logic Controllers C B0 C C5 C C6 C C7 A B A B A B A B A5 B5 A6 B6 A7 B7 A8 B8 A9 B9 5 Annuciator Logic Controllers 68 c5 c6 c7 B B B B B5 B6 B7 B8 B9 B0 B B B B B5 B6 C0 BUZZER RETURN BZ M / BZ CTROL SIGNAL LAMP DC() DC()

More information

IntesisBox BACnet/IP Server - Notifier ID3000 series

IntesisBox BACnet/IP Server - Notifier ID3000 series IntesisBox Server - Notifier ID3000 series Gateway for integration of Notifier ID3000, ID3002, ID50 and ID60 fire panels into enabled control systems. Integrate your Notifier fire panels into your BACnet

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual Instruction manual MTL process alarm equipment October 2016 CSM 725B rev 2 MTL RTK 725B Configuration Software Manual SECTION 1 - INTRODUCTION... 5 Basic Requirements... 5 SECTION 2 - SOFTWARE INSTALLATION...

More information

PTE0705 Electric Fence Monitor

PTE0705 Electric Fence Monitor PTE0705 Electric Fence Monitor The JVA logo is a registered trademark of JVA Technologies. JVA Technologies. TABLE OF CONTENTS DESCRIPTION... 2 QUICK START GUIDE... 3 FEATURES... 4 EXPLANATION OF TERMS...

More information

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001 SLATE Base Module R8001A1001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform can

More information

Added password for IP setup page : Password must be in IP format!

Added password for IP setup page : Password must be in IP format! NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP

More information

Alarm module for leak detection with webserver

Alarm module for leak detection with webserver This instruction document consists of 2 parts : one part about the assembly of the components and one part about configuration and starting-up of the system. The assembly is done by the qualified installer

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1. Data Sheet Ref: 90501085 WD-CS Water leak detection cable Technical Overview The WD-CS range of cable sensors are typically used to detect water leaks usually under floors, and are used in conjunction

More information

REA 105 Arc Protection Module. Operator s Manual

REA 105 Arc Protection Module. Operator s Manual REA 105 1MRS 751005-MUM Issued: 20.04.1998 Version: B2/26.5.2000 Checked: Approved: REA 105 We reserve the right to change data without prior notice. Contents: 1. General...4 1.1. Features...4 2. Safety...5

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

ECO N DATE DESCRIPTION OF CHANGE CHG

ECO N DATE DESCRIPTION OF CHANGE CHG Model Number: M21E-24-DIN Description: The product is a loop powered device which controls an unsupervised dual pole output channel suitable to manage 24VAC loads. The M21E-24-DIN is micro-controller operated,

More information

Public Safety DAS Annunciator Panel

Public Safety DAS Annunciator Panel Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This

More information

Analog Annunciator Unit SACO 16 A3. Product Guide

Analog Annunciator Unit SACO 16 A3. Product Guide Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Powerful, flexible and field-customizable 16-channel analog input signal annunciator unit A full

More information

Instruction manual. W440 AIS Sart Sniffer

Instruction manual. W440 AIS Sart Sniffer Instruction manual W440 AIS Sart Sniffer Ed. 1.2.0 () 9/2012 Doc: W440_1_2_0_ 1 2 3 Picture 1: Frontal view 4 3 Picture 2: Schematic diagram 4 Warning The crossed rubbish skip symbol indicates that the

More information

Interface and EOL Modules 8

Interface and EOL Modules 8 Interface and EOL Modules Interface Modules Series 420 25 Interface Modules Series 100 291 EOL Modules 293 254 Interface and EOL Modules Interface Modules Series 420 Interface Modules Serie 420 Interface

More information

M2000 Engine Controller

M2000 Engine Controller M2000 Engine Controller Integrated control and protection of diesel and gas engines for all purposes Especially suited for auxiliary generator sets 1 IN OPERATION 1 2 STARTFAIL 2 3 OVERSPEED RPM FAIL 3

More information

AU MX Digital Loop Card Installation Instructions

AU MX Digital Loop Card Installation Instructions 4100-6077AU MX Digital Loop Card Installation Instructions Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS - Follow the instructions in this installation manual. These instructions must be followed

More information

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments OMC-158-2 Ex interface unit Manual Version 1.2 August 2017 Author: Observator Instruments Revisions: 0.1 (October 2016) First issue 0.2 (December 2016) Prototype 0.3 (January 2017) Test release 1.0 (March

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

OilSET Installation and Operating Instructions. Oil Separator Alarm Device Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 18.11.2010 Internet: www.labkotec.fi 1/10 OilSET-1000 Oil Separator Alarm Device Copyright 2010 Labkotec

More information

BSR Addressable Fire Detection control panel. Installation operation manual

BSR Addressable Fire Detection control panel. Installation operation manual BSR-1116 Addressable Fire Detection control panel Installation operation manual ATTENTION!!! READ THE MANUAL BEFORE THE INSTALLATION AND PAY ATTENTION TO PARAGRAPH 2.6.3 AND 2.6.4. Page 2 from 36 Contents

More information

Electronic Emergency Telegraph. TG-1 and TG-1A

Electronic Emergency Telegraph. TG-1 and TG-1A Electronic Emergency Telegraph modification level Version Date Author Approved Remarks 01 23.10.2012 STO TK 1st issue Page: 1 TABLE OF CONTENTS 1. IMPORTANT SAFETY INSTRUCTIONS 3 1.1. QUALIFIED PERSONNEL

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

SUB-STATION ANNUNCIATOR INSTRUCTION MANUAL

SUB-STATION ANNUNCIATOR INSTRUCTION MANUAL SUB-STATION ANNUNCIATOR INSTRUCTION MANUAL Page 1 of 76 The following methods are used in this manual to alert the user to important information:- WARNING! Warnings are provided for operator safety and

More information

HRX Technical Manual. Version 1.2

HRX Technical Manual. Version 1.2 HRX 5000 Technical Manual Version 1.2 Contents: Specification...2 Connectors...5 RS-485 Network Connectors (J6 and J7)...5 RS-232 to Printer (J19)...6 RS-232 to PC (J8)...7 TCP/IP...8 Power (J21)...9 Fire

More information

FlameGard 5 MSIR HART

FlameGard 5 MSIR HART FlameGard 5 MSIR HART Multi-Spectral Infrared Flame Detector HART Communication with the FlameGard 5 Multi-spectral Infrared Detector The information and technical data disclosed in this document may be

More information

System 9000TS Sequence of Events Recorder

System 9000TS Sequence of Events Recorder System 9000TS Sequence of Events Recorder ms Event Recorder and combined Annunciator The RTK System 9000TS Sequence of Events Recorder leads the way in the latest technically advanced event and alarm management

More information

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection Technical Bulletin Arc Fault Monitor 4 Zones, 8 Sensors Features Four independent arc fault tripping zones 1 or 2 arc fault sensors per zone allowing up to 8 arc fault sensors per module Trip indication

More information

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Phone: 040 807-0 Fax: 040 807-259 Alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC display

More information

Operation and Maintenance Manual

Operation and Maintenance Manual (FKER Series) Repeater Panel (FKER, FKER, FKER8) Operation and Maintenance Manual Man-9EL Issue June Index Section Page. Introduction.... Safety and mounting.... Technical specification.... Control panel

More information