CONTENTS. 1 INTRODUCTION 2 Planning the installation 2 Nexus 8 installation example 3
|
|
- Amberly Rodgers
- 6 years ago
- Views:
Transcription
1 CONTENTS INTRODUCTION 2 Planning the installation 2 Nexus 8 installation example 3 INSTALLATION 4 Nexus 8 system diagram 4 Nexus 8 internal layout 5 Removing the gear tray 5 Mounting the panel / Cable entry 6 Mains connection / battery connection 6 Component wiring Bell boxes 8 Remote keypads 9 PIR detectors 11 Vibration detectors 12 Door contacts 14 Internal sounders 15 INITIAL POWER-UP 16 PROGRAMMING THE SYSTEM 16 System menus Engineer menu flow chart 17 Programming zone presets 18 Programming zones 19 Programming system options 20 Event Log Display Guide 21 System Test 22 RESETTING TO FACTORY DEFAULTS 23 GLOSSARY OF TERMS 24 TROUBLE SHOOTING / STOCK CODES 26 TECHNICAL SPECIFICATION 27 ENGINEER NOTES 28 Lynteck Ltd
2 INTRODUCTION ZONE PRESET OPTION 91 (PANEL DEFAULT) We recommended you read this manual before attempting installation in order to fully utilise the panels functions in your application. An understanding of the manual will lead to a quicker, easier installation of the system. Ground Floor VIBRATION DETECTOR (zone 4) DOOR CONTACT (zone 2) P.I.R. (zone 3) The Nexus 8 has been designed to simplify the installation process, making wiring easier and subsequently quicker. Individual tampers for each zone have replaced a single global tamper and each zone now has a 12v auxiliary power supply. A detachable gear tray aids wiring and protects the printed circuit board from damage. P.I.R. (zone 6) CONTROL PANEL (UNDER STAIRS) PLANNING THE INSTALLATION To maximise the system s effectiveness pre-plan the installation. P.I.R. (zone 5) KEYPAD DOOR CONTACT (zone 1) Consider the layout of the building and each of its access points. Use the pre-programmed system mode which is best suited to the building. (See programming guide p.18) First Floor DUMMY BELL BOX A common layout is shown below, using zone preset option 91 (see programming guide for details of how to set zone preset options p.18). This option has been chosen as it best suits the installation, taking layout and user requirements into account. As the majority of forced entry s are made through the front and back doors, they have been fitted with contacts. PIRs have been fitted guarding against entry through windows, with the exception of zone 4 which is protected by a vibration detector, making the room suitable for housing pets. Both zones six and seven are omitted in part sets 1 and 2, giving access to bedrooms during night setting. The panic attack is located upstairs close to each of the bedrooms as most burglaries take place at night. BELL BOX PANIC ATTACK (zone 8) P.I.R. (zone 7) 2 PLANNING THE INSTALLATION INSTALLATION EXAMPLE 3
3 INSTALLATION System Diagram CONTROL PANEL INTERNAL LAYOUT 6 Remote Keypad(s) External Sounder /Strobe Internal Speaker(s) Mains cable entry Mains fuse Auxiliary fuse Bell fuse Tamper switch Mains connection terminals Component connection terminals Transformer Alarm Outputs Battery fuse Mains supply 240v through 3amp fused spur Internal Battery Battery connection terminals Battery 8 Detection zones GEAR TRAY REMOVAL To release the gear tray, unscrew and tilt away from backplate. Door Contact(s) PIR Detector(s) Vibration Detector(s) To replace, first place left side under catches, then tilt home and replace screw. 4 SYSTEM DIAGRAM PANEL LAYOUT GEAR TRAY REMOVAL 5
4 MOUNTING THE PANEL MAINS CONNECTION Use the template on the rear of the Nexus 8 box to aid hole marking. Drill used should be a size 10 mason bit. Plug holes with rawl plugs. Use slotted fixing holes to help level the panel before fixing it in place with four 1.5 x8 wood screws. Consumer Unit 3Amp Spur PANEL BLUE GREEN/ YELLOW BROWN N E L NEUTRAL EARTH LIVE Mains supply is connected to the panel via a three-way green terminal block located on the transformer below the mains cable entry. The supply should come directly from a consumer unit through a 3amp fused spur. CABLE ENTRY BATTERY CONNECTION Cable Entry's 10 individual cable entry s are sited beneath the gear tray. Each is individually marked for ease of cable identification. A sealed lead acid rechargeable battery must be connected to the panel via the two way terminal block (B+/B-). This is situated next to the battery fuse on the transformer. Battery Fuse B+ B- 6 PANEL MOUNTING CABLE ENTRY MAINS CONNECTION BATTERY CONNECTION 7
5 BELL BOXES REMOTE KEYPADS Single keypad STR Lynteck Bell Box TRG HOLD + HOLD - TAMP R Nexus 8 BELL/STROBE ZONE 1 TPR HOLD TRG STR Keypad terminals D Core Cable (3-cores used) SPKR + D - KEYPAD ZONE 5 Always consult manufacturers instructions before installation. Use 6-core cable (5-cores required). The Nexus 8 allows up to 4 remote keypads to be used with the system. Wiring is via three terminal blocks located at the bottom of the keypad Cable entry to the keypad is from either top or bottom knockout. Use 4-core cable (3-cores required) Bell Box Wiring Reference Table Nexus 8 Panel connection HOLD+ HOLD- TPR TRG STR Suggested wiring colour RED Black WHITE BLUE GREEN Ventcroft Classic/Spirit H OFF+ H OFF- RTN TRG STB Two or more keypads Keypad 1 Keypad Texecom Veritas Azura 360 A D C B S CQR Integra HS +VE 0V RETURN SIREN-TRIG STROBE-TRIG + D - ADE Sonade* D A T B STROBE - D + - D + - SPKR KEYPAD ZONE 5 * NOTE - Connect STROBE+ to D 4-Core Cable (3-cores used) Nexus 8 8 BELL BOX WIRING KEYPAD WIRING 9
6 ADDRESSING ADDITIONAL KEYPADS If two or more keypads are used in an installation, each has to be assigned an address number in order to communicate with the end-station. This address number is factory set to 1 and so must be changed on additional keypads. To set address number on an additional keypad Ensure keypad to be added is not yet powered. Remove keypad s front cover. Electrically connect keypad to endstation. The keypad will display its address number i.e. Press 1 to 4 to change keypads address. Press YES to accept and a conformation bleep will be heard. Replace keypad cover and test keypad can control the system. PANIC ATTACK PIR DETECTORS Single PIR Harrier PIR +12v- TAMP RELAY Consult detectors instructions before installation. If two or more PIRs are connected to a zone, wire power in parallel, alarm and tamper in series. Use 6-core cable. 6-Core Cable ZONE 1 LED ZONE 2 6 The remote keypad also features a panic attack function. Panic attack is operated by pressing both buttons situated above the keypad display. Two or more PIRs ZONE 1 LED ZONE 2 Panic attack function can be disabled if required. (See programming menu p.20) +12v- TAMP RELAY +12v- TAMP RELAY 10 PROGRAMMING ADDITIONAL KEYPADS P.I.R. WIRING 11
7 VIBRATION DETECTORS Single Non-latching Vibration Detector Lynteck Vybe ZONE 2 ZONE 3 Latching Vibration Detector (7 - Cores) Lynteck Lynteck Pro-Vybe Pro-Vybe BELL/STROBE T T C - + A A T T C - + A A C LATCH ZONE 1 Connection terminals T T - + A A 6-Core Cable 8-Core Cable (7-cores Used) If two or more detectors are connected to one zone, power is wired in parallel, whereas alarm and tamper circuits must be wired in series. Where 6-cores are used to wire latching detectors, power supply is taken from tamper circuit. The zones + terminal should not be used. Two or more Non-Latching Vibration Detectors T T - + A A T T - + A A ZONE 2 ZONE 2 6-Core Cable ZONE 3 ZONE 3 Latching Vibration Detector (6 - Cores) Lynteck Lynteck Pro-Vybe Pro-Vybe BELL/STROBE T T C - + A A T T C - + A A C LATCH ZONE 1 NOT USED 6-Core Cable 12 VIBRATION DETECTOR WIRING VIBRATION DETECTOR WIRING 13
8 MAGNETIC DOOR CONTACTS Single Door Contact WIRING INTERNAL SPEAKERS Single Speaker BELL/STROBE ZONE 1 S + SPKR KEYPAD 4-Core Cable - + If two or more contacts are wired to a zone, alarm and tamper are wired in series. A maximum of two 16 ohm or one 8 ohm internal speakers can be wired to the speaker contacts, power is to be connected in parallel. Two or more Door Contacts Two Speakers BELL/STROBE ZONE 1 S - SPKR KEYPAD 4-Core Cable DOOR CONTACT WIRING INTERNAL SPEAKER WIRING 15
9 INITIAL POWER UP Apply mains power to the system This will start the panel in alarm mode and display Enter engineer code ( default) to silence alarm Re-enter code to reset panel and enter engineer menu PROGRAMMING THE SYSTEM System menus Master User Menu Normal User Menu See USER GUIDE Engineer Menu The three system menus each give a differing amount of control over the operation of the panel. Engineer Menu (flow chart p.17) Accessed by entering the engineer code ( default). System can be unset by engineer only if set by engineer. Gives access to all master user functions as well as system programming. System programming can only be carried out from within the engineer menu. 16 PROGRAMMING THE PANEL 17 ENGINEER MENU FLOW-CHART
10 PROGRAMMING GUIDE * ** * Soak time - 14 days ** Double knock time - 10 seconds. 18 PROGRAMMING ZONE PRESETS PROGRAMMING ZONES 19
11 EVENT LOG DISPLAY GUIDE Upon accessing the panels log, the last 64 events can be viewed in the order they happened. 20 PROGRAMMING SYSTEM OPTIONS LOG DISPLAY GUIDE 21
12 SYSTEM TEST LOAD TEST Bell, strobe and internal sounder outputs are activated. This allows the engineer to perform voltage load measurements on all cables in order to comply to NACOSS requirements. WALK TEST Zones can be turned on or off to avoid unwanted triggers by others during test. The successful test of each zone is met with both confirmation bleep(s) and keypad display RESETTING TO FACTORY DEFAULTS The Nexus 8 incorporates non-volatile memory which retains all access codes and pre-programmed settings. If the user forgets their access codes or the default factory settings are to be returned, the memory has to be completely reset. To Reset Codes Remove mains power, open cover and disconnect battery Remove auxiliary fuse. Apply mains, reconnect battery and replace auxiliary fuse. All codes are now reset. DEFAULT FACTORY CODES Engineer Code 7890 Master User Code 1234 Normal User Code Disabled To Reset Factory Program Settings Default factory program settings are returned by programming zone option 91 (See programming guide p.18) DEFAULT FACTORY SYSTEM OPTIONS (p.20) Full Set Entry Time 30sec Full Set Exit Time 30sec Part Set 1/2 Entry Time 30sec Part Set 1 Exit Time 30sec Part Set 2 Exit Time 0sec Bell Cut Off Time 15min Part Set 1/2 Volume 0 Chime Volume 5 System Re-Arms 3 Part Set Mode 0 Strobe Confirm Set 0 Number of Keypads 1 Reset Mode 0 Keypad PA Buttons SYSTEM TEST RESETTING TO FACTORY DEFAULTS 23
13 GLOSSARY OF TERMS Bell Box (page 8) Bell Cut Off Time (page 20) Door Contact (page 14) Engineer Code (page 16) Factory Defaults (page 23) Final Door Set (page 19) Forced Set (page 21) Full Set (page 17) Gear Tray (page 5) Internal Sounders (page 15) Master User Code (See user guide) Normal User Code (See user guide) Comprising of a sounder and strobe the bell box is located externally. Amount of time the panel alarms for when it has been triggered into alarm mode A magnetic switch detecting the opening / closing of the door it is fitted to. 4-digit code entered by installer to access engineer menu giving programming,test and system options. Panel settings which are preset before programming. Overrides exit time by setting the alarm upon leaving the building. System is still set in an event that would otherwise stop it working leaving the building unprotected. Complete setting of the system, all zones are activated. Removable tray to which the panel is attached. The gear tray aids wiring and protects the. The panel comes complete with an internal sounder, which is fixed on the underside of the gear tray. Up to two more can be used with the system. 4-digit code used to access master user menu from which panel functions are activated / deactivated. 4-digit code used to access the normal user menu which gives limited panel function control. Panic attack (page 10) Part Set (page 17) P.I.R. (page 11) Remote Keypad (page 9) Remote Keypad PA (page 20) Reset Mode (page 20) Tamper Circuit Walk Test (page 22) Zones Zone Type (page 19) Zone preset options (page 18) 24 GLOSSARY OF TERMS GLOSSARY OF TERMS Each remote keypad has 2 panic attack buttons, which, when pressed simultaneously trigger the alarm. Setting of the system with user defined zones deactivated. The Nexus 8 incorporates 2 part-set modes. Triggers the alarm upon detecting the movement of infra-red body heat. Remotely controls the operations of the panel and incorporates twin panic attack buttons. Programs the keypad s panic attack buttons on or off. Determines whether the customer as well as the engineer can reset the panel. Gives wiring constant protection from interference or damage. Allows the imitation of a burglary in order to test each zone is working. Circuit loops to which detection devices are connected. Zones can be programmed as defined types (alarm, fire, panic attack etc.) in order to aid a more professional installation. Pre-programmed zone options which are tailored to suit common building layouts. 25
14 TROUBLESHOOTING NO MAINS POWER TO THE UNIT Check the mains fuse and replace if blown. Check mains supply is connected correctly. Check supply terminals on transformer and. NO BATTERY POWER TO THE UNIT Check battery fuse and replace if blown. Check the battery is wired correctly to the terminals beside the battery fuse. NO MAINS OR BATTERY POWER TO THE UNIT Check wires are not shorting. NO SOUND FROM THE UNIT Check that speaker is correctly connected to speaker terminals located on the top left of the. Check that volume has not been programmed on low setting (See system programming p.21). LYNTECK STOCK CODES Nexus 8 Panel Remote Keypad Harrier PIR White/Blue Xenon Bell Box White/White LED Bell Box Vybe Pro-Vybe 4-Core Cable 6-Core Cable 8-Core Cable Diamond Sounder - 8ohm Diamond Sounder - 16ohm Panic Attack Button LY LY LY LY LY LY LY LY LY LY LY LY LY TECHNICAL SPECIFICATION PHYSICAL Dimensions Panel 250mm x 235mm x 60mm Keypad 95mm x 137mm x 37mm Construction POWER SUPPLY Power input Power input fuse Battery charge voltage Rechargable battery capacity PANEL V0 rated 3mm polycarbonate 240v a.c. 20mm 250mA time delay 13.8v D.C. 12v sealed lead acid 1.2 to 7.2 AH Current 12 D.C. all 8 zone contacts closed. Enstation Keypad System Unset 45mA 45mA System Set 45mA 15mA In Alarm 160mA 45mA Bell fuse 20mm 1Amp quick blow Auxiliary fuse 20mm 1Amp quick blow Battery fuse 20mm 3Amp quick blow 26 TROUBLESHOOTING PRODUCT STOCK CODES TECHNICAL SPECIFICATION 27
15 ENGINEER NOTES Customer name - Installation address - Telephone number - Date of installation - Contract number - Engineer name - Technical support telephone numbers - Head Office Mobile AREA COVERED / ZONE TYPE Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Area covered Full Set Part Set 1 Part Set 2 SYSTEM SETTINGS Full Set Entry Time secs Full Set Exit Time secs Part Set 1 Entry Time secs Part Set 1 Exit Time secs Part Set 2 Entry Time secs Part Set 2 Exit Time secs Part Set 1 Volume Part Set 2 Volume Bell Cut Off Time mins Chime Volume System Rearms No. of Keypads Service Timer weeks Part Set Mode Keypad PA Buttons Reset Mode TROUBLE SHOOTING Lynteck Ltd
THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panel with Communicator Interface
THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL Security Control Panel with Communicator Interface Table of Contents Table of Contents Section Page 1 Programming Summary 4 1.1 Programming Menu 4 1.1.1
More informationSECURIT 700L PLUS ENGINEERING MANUAL
SECURIT 700L PLUS ENGINEERING MANUAL C & K Systems Ltd 13/03/97 C031-096-02 NEW ENHANCED FEATURE SET Securit 700L PLUS Engineering instructions INTRODUCTION The Securit 700L is a microprocessor intruder
More informationContents. Introduction... 2 Mains Safety... 2 Good Working Practice... 2
TM C P 7 / C P 8 I NSTALLATION I NSTRUCTIONS TM Contents Introduction...................... 2 Mains Safety.................. 2 Good Working Practice.......... 2 Installation....................... 3 Control
More informationINSTALLATION MANUAL SECURIT 802 CONTROL PANEL
INSTALLATION MANUAL SECURIT 802 CONTROL PANEL S802 CONTENTS Warnings 2 Standards 2 Warranty Statement 2 Product Description 2 Available Parts 2 Intended use 2 Specifications 3 Processor Version 3 Power
More informationContents. Introduction... 2 Mains Safety... 2 Good Working Practice... 2
TM TM C P 8 L L C D I NSTALLATION I NSTRUCTIONS Contents Introduction...................... 2 Mains Safety.................. 2 Good Working Practice.......... 2 Installation....................... 3 Control
More informationAdvantage 6 Alarm Panel
Issued ugust 1997 9778 Instruction Leaflet dvantage 6 larm Panel Introduction The control panel is designed to be simple to install, programme, and to use. The 16 button keypad allows you to select, change,
More informationSTERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL
STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL IMPORTANT: Please note the Sterling 10 LCD keypad is not compatible for use with the Sterling 10 ICON keypad. RINS1413-1 Pyronix
More informationTS400 & TS410. Intruder Alarm Control Panels. Operating Instructions
TS400 & TS410 Intruder Alarm Control Panels Operating Instructions Zone Location Home Set Chime 1 Armed / Omitted 2 Armed / Omitted 3 Armed / Omitted 4 Armed / Omitted 5 Armed / Omitted F. Exit Always
More informationINSTALLATION GUIDE. For products. Gardtec 370 & 581
INSTALLATION GUIDE For products Gardtec 370 & 581 Contents INTRODUCTION Introduction..................................3 Tools Required...............................3 Other Equipment Required......................3
More informationGARDTEC 580. Installation Instructions
GARDTEC 5 0 0 S E R I E S GARDTEC 580 Installation Instructions Contents Introduction 1 Planning the Control Panel Location 2 Installation 2 Cable Entries 3 Mains Supply Connection 4 Terminal Block Connections
More informationGen4 Domestic Intruder Panels RELIABLE AND FLEXIBLE INTRUDER PANELS. Domestic applications
Gen4 Domestic Intruder Panels RELIABLE AND FLEXIBLE INTRUDER PANELS Domestic applications Overview and features 8 Zones Each one is separately identified on the keypad and provides ample security detection
More informationThe most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation
The most user friendly Contents Section 1 Overview of System 1.1 Kit Contents 1.2 Tools Required 1.3 System Features Security Alarm System L S 4 0 0 Section 2 Planning your Installation 2.1 Location of
More informationAP10LED 10 Zone onboard LED Alarm Panel. Engineering Manual
AP10LED 10 Zone onboard LED Alarm Panel SAFETY Engineering Manual Before proceeding with the installation, please note the following safety warnings: DO NOT connect the mains supply directly to the product,
More informationData Sheet. Abacus intruder alarm systems
Data Pack Issued March 2001 232-4336 Data Sheet bacus intruder alarm systems n intruder alarm system is a secondary form of protecting a property. here is little or no point in fitting a system if you
More informationLS800S Intruder Alarm System. Engineering Manual
LS800S Intruder Alarm System Engineering Manual Table of Contents Section 1 Overview of System 1.1 Kit Contents 1.2 Tools Required 1.3 System Features Section 2 Planning your installation 2.1 Location
More informationTS5160. Installation & User Guide. Compatible Equipment. CPA6 0M - Output Module Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only)
Installation & User Guide Compatible Equipment CPA6 0M - Output Module 9040 - Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only) 496527 Issue A 1 of 16 TS5160 Overview Introduction Specification
More information2200 and 2200L ALARM CONTROL SYSTEMS
2200 and 2200L ALARM CONTROL SYSTEMS OPERATING INSTRUCTIONS MODELS: 2200 (fitted software 3.4 or later) 2200L (fitted software 3.9L or later) Castle Care-Tech Ltd. 2200/2200L Alarm System Operating Manual
More informationTHANK YOU FOR VOTING TEXECOM THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels 1 INS167
Veritas User Guide Quick Reference Guide THANK YOU FOR VOTING TEXECOM THANK YOU FOR VOTING TEXECOM USER GUIDE Security Control Panels 1 INS167 Overview Premier Series User Guide 1. Overview Introduction
More informationNEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK.
VI64 Version:1.1 Issued 06/12/2007 INTRODUCTION Ventcroft s external sounder/strobes offer an unsurpassed range of models which provide for virtually any installation need. Most models feature a robust
More informationUSER MANUAL CEF AP28 CONTROL PANEL
USER MANUAL CEF AP28 CONTROL PANEL AP28 WARNINGS This product has mains voltage present within the housing. Please take the necessary precautions in not allowing any liquid to spill on or into the housing.
More informationPYRONIX LIMITED, Pyronix House, Braithwell Way, Hellaby Rotherham South Yorkshire S66 8QY England
PYRONIX LIMITED, Pyronix House, Braithwell Way, Hellaby Rotherham South Yorkshire S66 8QY England Tel: 01709 700100 Fax: 01709 701042 INT'L Tel: +44 1709 700100 INT'L Fax: +44 1709 701042 WARRANTY This
More information2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM
2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM OPERATING INSTRUCTIONS MODELS: 2300 2500 2700 This information is relevant to systems fitted with Issue 4.1 (or later) Master Keypad Software, also to Networked
More informationSECURIT 700L USER MANUAL
SECURIT 700L USER MANUAL C & K Systems Ltd 6/12/95 Securit 700L User instructions This manual will give you all the information you need to operate and control the Securit 700L Control Panel. This manual
More informationHARDWIRED CONTROL PANELS
USER'S GUIDE HARDWIRED CONTROL PANELS Cooper Security Limited 2007 Every effort has been made to ensure that the contents of this book are correct. However, neither the authors nor Cooper Security Limited
More informationTHANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels
THANK YOU FOR VOTING TEXECOM USER GUIDE Security Control Panels User Guide Summary User Guide Summary Full Set Press Full " Part Set Press Part Set Number # or $ Press Part % Unset Omit Zones Press Full
More informationSECURIT 703 USER MANUAL
SECURIT 703 USER MANUAL C & K Systems Ltd THE SECURIT 703. USER INSTRUCTIONS VERSION 1.4 September 1996 C031-111-03 1.0 SETTING 1.1 FULL SET To start the exit procedure ensure all alarmed zones are clear
More informationM800, M800iD Plus, M1000 and M3000. User's Guide
M800, M800iD Plus, M1000 and M3000 User's Guide Cooper Security Limited 2005 Every effort has been made to ensure that the contents of this book are correct. However, neither the authors nor Cooper Security
More informationTHIS GUIDE SUPPORTS MATRIX 424 & 832 CONTROL PANELS
THIS GUIDE SUPPORTS MATRI 424 & 832 CONTROL PANELS Software Version V1 08 RINS 295 ISSUE 4 DECEMBER 2001 WARRANTY This product is sold subject to our standard warranty conditions and is warranted against
More informationAccenta/Optima. User Guide. UK Security Panels. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number:
Accenta/Optima User Guide ZONE 1 2 3 4 5 6 7 8 9 Chime Omit Prog PA 0 1 2 3 4 5 6 7 8 9 CHIME OMIT RESET PROG SET Accenta + TA PA DAY POWER PA! " # $ % & 0 1 2 3 5 6 7 8 Chime Omit Reset Prog 4 9 Set PA
More informationIntroduction. When using an LED keypad for Abacus 6P (or some older Abacus panels) refer to the LED Operator instructions guide (Part No. Y6055).
Introduction The Abacus range of intruder alarm panels are manufactured by Detection Systems, using advanced microprocessor technology, this allowing greater flexibility and ease of use. Whilst great care
More informationHA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE
D (OPERATION) INITIATE A DYNAMIC BATTERY TEST The system tests the back-up battery once every 24 hours. The owner can initiate a dynamic battery test at any time with the following codes while the system
More informationMaster User Guide Premier Elite Series
Master User Guide Premier Elite Series INS177-9 Overview Premier Elite Series Master User Guide Contents 1. Overview... 5 Introduction... 5 Keypads... 7 Emergency Keys... 8 The Quick Arm Keys... 9 Keypad
More informationIDS816 User Manual H Issued January 2009
1 Contents Glossary-------------------------------------------------------------------------------------------------------------------6 1. Introduction to the IDS 816---------------------------------------------------------------------------7
More informationSentry 4 Zone Alarm Panel User Manual
TM TM Sentry 4 Zone Alarm Panel User Manual PLEASE NOTE: A 16Vac / 16VA Transformer MUST be used with this product. Contents 1. Introduction. 2. Programming a Remote. 3. Deleting all Remote s. 4. The siren
More informationPARAGON PLUS USER INSTRUCTIONS USER INSTRUCTIONS J?>5 J?>5 J?>5 J?>5 J?>5 J?>5 B??=
D D D < USER INSTRUTIONS USER INSTRUTIONS PYRONIX LIMITED JULY 2000 RINS 154 Issue-1 INSTALLATION OMPANY: TEL: ADDRESS: ONTAT: PARAGON D * PLUS &J?>5@B?7B1==9>7D1DE5 J?>5 J?>5 J?>5 J?>5
More informationContents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...
2 Contents Glossary...7 1. Introduction to the IDS805...8 1.1 Notes...8 2. Understanding the Keypad Indicators...8 3. Operation of the Keypad...9 4. System Information...10 4.1 Programmed Functions...10
More information3 ZONE WIREFREE BURGLAR ALARM INSTALLATION & OPERATING INSTRUCTIONS
WIREFREE PIRs WIREFREE KEYPAD AND CASE WIREFREE REMOTE WIREFREE DOOR CONTACT ukpanels.com Please note: Before you start to install this Micromark Alarm, we advise that you should take adequate safety precautions
More informationFTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS
QUICK USER GUIDE FOR, 2 & 4 ZONE PANELS INDICATORS COLOUR INDICATION MON FAULT Yellow On when a fault condition has occurred, or if no other fault Led is on, this indicates 24v auxiliary fuse failure.
More informationIntruder - Fire - Water Combined Alarm
65 Intruder - Fire - Water Combined Alarm Installation Manual and User Operating Instructions TALE OF CONTENTS Page First Power-Up 2 Power Supply Unit 3 Input & Detection Circuits 3 Output & Alarm Circuits
More informationTS700. Intruder Alarm Control Panel. Installation & Programming Instructions OPEN
TS700 Intruder Alarm Control Panel OPEN OPEN Installation & Programming Instructions Contents Overview Introduction......................... 3 Control Panel........................ 3 Remote Keypads and
More information8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u
8 plus and16 plus User s Guide GALAXY 16+ V2.XX 06.22 TUE 30 JUN 1 2 3 4 5 6 7 8 9 0 * # A u B u ent esc IU1-0018 ZST 962 Issue 2 Contents INTRODUCTION... 1 Glossary of Terms... 3 KEYPAD INFORMATION...
More informationEC-P Zone Intruder Alarm System
EC-P10 10-20 Zone Intruder Alarm System Installation Manual Contents 1. System Overview... 4 System Configuration... 4 Control Panel... 5 Remote Keypads... 5 EC-LED Remote Keypad... 5 EC-LCD Remote Keypad...
More informationManager Guide. Indications on the system. Using System. Indications
Manager Guide This User Guide tells you how to operate your intruder alarm system. To simplify this User Guide we have assumed that the alarm system has been installed by a professional intruder alarm
More informationMatrix Installation Manual. Software Version 4. EN Security Grade 2 Environmental Class 2 RINS918-1
Matrix 424 832 832+ Installation Manual Software Version 4 RINS918-1 EN50131-1 Security Grade 2 Environmental Class 2 CONTENTS 1. INSTALLATION & CABLING RULES...1 1.1 Tools Required... 1 1.2 Mains Wiring...
More information5000 SERIES 8 ZONE INSTRUCTION MANUAL
5000 SERIES 8 ZONE INSTRUCTION MANUAL NESS SECURITY PRODUCTS 4/167 PROSPECT HIGHWAY SEVEN HILLS. 2147 NSW AUSTRALIA SYDNEY Phone: (02) 8825 9222 (Head Office) BRISBANE Phone: (07) 3343 7744 MELBOURNE Phone:
More informationControl/Communicator Installation Manual
DAS NETWORX NX-12 Control/Communicator Installation Manual General Description...2 Ordering Information...2 Option Definitions...3 Programming the LED Code Pads...5 Programming the NX-12...9 Types of Programming
More informationHILLS Series LED Code Pad User Manual
HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2
More informationEngineer Reference. EN :2006+A1:2009 EN :2009 EN :2008 EN :2005+A1:2008 Security Grade 2 Environmental Class II
EN50131-1:2006+A1:2009 EN50131-3:2009 EN50131-6:2008 EN50131-5-3:2005+A1:2008 Security Grade 2 Environmental Class II Engineer Reference INTERNAL SIREN WARNING The Enforcer 32-WE control panel contains
More informationInstallation Manual Premier 412/816/832. Issue 10
Installation Manual Premier // Issue 0 Premier // Installation Manual 5. Operating the System Introduction Before attempting to operate the alarm system ensure you have familiarised yourself with all the
More informationTS700. Intruder Alarm Control Panel OPEN ENT 0 ESC
TS700 Intruder Alarm Control Panel OPEN _ ~ A 1 2 3 B 4 5 6 C 7 8 9 D ENT 0 ESC Setting the System Ent er your pa sscode XXXX then leave the protected area. Unsetting the System Go directly to the keypad
More informationLS5000. Contents. Section 1 Overview of System. Section 1 Overview of System. Section 2 Planning your Installation. Section 3 Installing your System
LS5000 Contents Section 1 Overview of System Section 2 Planning your Installation Section 3 Installing your System Section 4 Using the System Section 5 ming the System Section 6 Engineer ming Section 7
More informationCPA6. Installation & User Guide. Intelligent Security & Fire Ltd. Compatible Equipment
Installation & User Guide Compatible Equipment CPA6 OM - Output Module 9040 - Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only) 496524 Issue A 1 of 16 CPA6 Overview Introduction Facilities
More informationInstallation Manual RINS1211-4
Installation Manual 2x 2x RINS1211- Contents Page System Overview Technical Specification 5 Overview 6 The Control Panel 6 The Printed Circuit Board The Tamper Spring and Connections 8 Connections 9 Transformer
More informationIntruder alarm system Operating Instructions
Intruder alarm system Operating Instructions 0 2 3 4 5 6 7 8 9 CHIME OMIT RESET PROG SET S Power 0 2 3 5 6 7 8 Chime Omit Prog 4 9 Set AccentaG3 mini Servicing organisation details Servicing organisation
More informationTS700. Intruder Alarm Control Panel ENT 0 ESC
TS700 Intruder Alarm Control Panel OPEN _ ~ A 1 2 3 B 4 5 6 C 7 8 9 D ENT 0 ESC Setting the System Ent er your pa sscode XXXX th en lea ve th e pro tect ed a re a. Unsetting the System Go dir e ct ly to
More informationWatchguard WGAP864 User Manual
Watchguard WGAP864 User Manual v1.0 Issued September 2016 1 2 Table of Contents Glossary... 5 1. Introduction to your Watchguard WGAP864... 6 2. Before Operating your Alarm System... 6 3. Understanding
More informationCC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom
CC880/LP880, SC8016 EN Operators Guide Solution-16, Solution-16 Safecom CC880/LP880, SC8016 Operators Guide EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch
More informationPNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel
PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum
More informationSaffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.
Saffire+ 8-12 User & Installation Manual IMPORTANT This manual should be left with the panel after installation. We reserve the right to change product specifications without prior notice. Copyright VRC
More informationUSER GUIDE HARDWIRED CONTROL PANELS
USER GUIDE HARDWIRED CONTROL PANELS Scantronic Contents 1. Introduction... 3 The Alarm System... 3 The Keypads... 3 The 725r Remote Setting Device... 6 About This Guide... 6 2. Everyday Operation... 7
More informationScantronic Leading the way in security
USER GUIDE (16 ZONE) HARDWIRED CONTROL PANEL Scantronic Leading the way in security Contents 1. Introduction 3 The 9800+ (16 zone) System... 3 The Keypad... 3 About This Guide... 5 2. Everyday Operation
More informationTS2500. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT ESC. Setting the System. Unsetting the System RE SET
E n t er y ou r pa s s c o de X X X X th en l ea v e th e p r o tec t e d a re a. G o dir e ct ly to t h e k e yp ad an d en te r y ou r p as s c o d e X X X X. E n t er y ou r pa s s c o de X X X X f
More informationWelcome to. Welcome to Security and Peace of Mind CASTLE CARE TECH CARE TECH CARE TECH CARE TECH
Welcome to Welcome to Security and Peace of Mind CARE TECH CARE TECH CARE TECH CASTLE CARE TECH Contents Introduction A1-3 Using Meridian with your PIN Code B1-7 Using Meridian with your Tag C1-8 When
More informationIDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00
INHEP DIGITAL IDS S E C U R I T Y IDS816 User Manual MANUAL NO. 700-283-02A ISSUED November 2004 VERSION 1.00 Contents 1. Introduction to the IDS816... 4 2. Understanding the Keypad Indicators... 4 3.
More informationHARDWIRED CONTROL PANELS
USER GUIDE 9651 HARDWIRED CONTROL PANELS Contents 1. Introduction...3 The Alarm System...3 The Keypad...3 About This Guide...5 2. Everyday Operation...6 How Do I Know if the System is Working?...6 Setting
More informationInstallation, Operating and Maintenance Manual
STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS
More informationAlgo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)
Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS) INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0)
More informationIDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44
Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Away Arm Stay Arm Stay Arm & Go H old down [ 1] for 1 second H old down [ 5] for 1 second H old down [ 6] for 1 second Panic Fire Medical
More informationInstallation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels
Installation and user manual for the FX range of fire panels 1, 2, 4 and 8 zone panels Contents Panel installation 3 Panel connections 3 Wiring connection drawings 4 Panel facilities 6 Installation check
More informationUSER GUIDE TEL. LINK RING RF LINK/LOW BAT. MIC. IMPORTANT: ALWAYS KEEP THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE
SolarGuard SG4000, ES4000 Dial Up Alarm System USER GUIDE 1 2 3 S 4 5 6 P 7 8 9 L 0 # / P /R AC POWER TEL. LINK RING LI INE CUT RF LINK/LOW BAT. MODE/MEMO MIC. PANIC IMPORTANT: ALWAYS KEEP THIS INSTRUCTION
More informationExcel-EN Conventional Fire Control Panel
Available as 2, 4, 6, 8,10 or 12 zones Approved to EN54-2 & 4 Modular expansion zone cards Programmable relays and outputs Optional additional sounder circuits Optional additional programmable outputs
More informationUSER GUIDE. Security Control Panels INS046-7
USER GUIDE Security Control Panels INS046-7 Summary Summary Summary Full Set Enter Your Code Press Full " Part Set Enter Your Code Press Part Set Number Press Part Unset Enter Your Code Omit Zones Enter
More informationRANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL
RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...
More informationIDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00
INHEP DIGITAL IDS S E C U R I T Y IDS816 User Manual MANUAL NO. 700-283-01 B ISSUED DEC 2004 VERSION 2.00 Contents 1. Introduction to the IDS816... 4 2. Understanding the Keypad Indicators... 4 3. Programmable
More informationACP10 & ACP50 Security Systems
ACP10 & ACP50 Security Systems System Configuration LCD Keypad LCD Keypad LED Keypad LED Keypad 4-wire Bus ACP10 & ACP50 AEX10* AEX10* AEX10* AEX10* * ACP50 Only Control Panels The ACP10 control panel
More information0$; Installation Instructions. Computerized Control Panel '(6&5,37,21 63(&,),&$7,216 DE5011 1
0$; Computerized Control Panel Installation Instructions '(6&5,37,21 The MAX-5 is a highly reliable, cost effective control panel for residential and commercial applications. Besides being simple to install
More informationIDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00
INHEP DIGITAL IDS S E C U R I T Y IDS816 User Manual MANUAL NO. 700-283-01C ISSUED APRIL 2005 VERSION 2.00 Contents 1. Introduction to the IDS816... 4 2. Understanding the Keypad Indicators... 4 3. Programmable
More informationWIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER
BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.
More informationWARNING FIRE DOOR CLOSING
PRODUCT INSTRUCTIS Stock Code: 088 FCP - Lite Floats Road, Wythenshawe Manchester, M 9WB Tel: + (0) 9 Fax: + (0) 9 Doc No PI - 88 Iss:.0 WARNING FIRE DOOR CLOSING STOP Contents ) Blank ) Features and
More informationSolution Ultima 862 Operators Manual ISSUE 1.10
Solution Ultima 862 Operators Manual ISSUE 1.10 Solution Ultima 862 Operators Manual Copyright 2001 by, SYDNEY, AUSTRALIA Document Part Number MA486O DOCUMENT ISSUE 1.10 Printed 24 April 2001 This documentation
More informationRPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev
RPSMLR2 RPSMLR2BB Panic Device Power Controller Installation Guide LISTED Rev. 102715 Overview: RPSMLR2BB, RPSMLR2 will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed
More informationSecurity System. User Guide for the LED Command Center
Security System User Guide for the LED Command Center National Security Systems Inc (800)457-1999 MY SECURITY COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY
More informationFire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96
Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 XL-2G Gold Product Overview 7 Zones (6 programmable + panic or keyswitch zone) Fast Loop Response
More informationControl Panel User Guide
Fire Detection & Alarm System Control Panel V4.14 Control Panel User Guide (TO BE RETAINED BY USER) 26-0397 Issue 6 Fike s policy is one of continual improvement and the right to change a specification
More informationSecurit 7 Alarm Panel
Securit 7 larm Panel Stock No. 436-881 ntroduction The Securit 7 is a microprocessor controlled intruder alarm panel. t features seven zones of which five are programmable and two dedicated to entry/exit
More informationRacal-Guardall. Countess. User Instructions. Countess
Racal-Guardall Countess User Instructions Countess INCORRECT ACCESS CODES If three incorrect access codes are entered within five minutes a tamper fault will be generated. 1. SETTING FULL SYSTEM Enter
More informationTHANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. External Sounder & Strobe Unit
400 THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL External Sounder & Strobe Unit Contents Section Page 1. Installation 3 1.1 Mounting the Unit 3 1.2 Patented Engineer Hold-Off Mode 3 1.3 Installing
More informationDL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL
DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION... 2 2. STANDARD AND OPTIONAL PARTS LIST... 2 3. FEATURE DEFINITIONS... 3 4. TERMINAL DRAWING AND SPECIAL
More informationUnderstanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...
TABLE OF CONTENTS...Glossary of terms...2...code Pad Diagram...3 Understanding the Code Pad lights...4 Code Pad tones...5 Fully arming the system On MODE...6 Fully arming the system - Quick Arm MODE...6
More informationENGINEER S AL.
VISTA 25 UK ENGINEER S MANUAL AL i ii Contents SECTION 1: WIRING AND SAFETY INFORMATION... 1 General...1 Siting...1 Fixing... 1 Ventilation...1 Cabling...1 Mains Supply Connections...2 Cable Type...3 Fuses...3
More informationDigiplex System V2.14 / V2.2ACC. Control Panel Programming Guide
Digiplex System V2.14 / V2.2ACC Control Panel Programming Guide Table of Contents Getting Started...2 What Do I Do First?...2 How Do I Program the Control Panel?...2 Single Digit Entry Method...2 Multiple
More informationTABLE OF CONTENTS TABLE OF CONTENTS 1
TABLE OF CONTENTS TABLE OF CONTENTS 1 FEATURES 2 Keypad Programmable... 2 EEPROM Memory... 2 Static/Lightning Protection... 2 Supervision... 2 Operation... 2 SPECIFICATIONS 2 PC1550 Control Panel... 2
More information2-ZONE EASYFIT INTRUDER ALARM
SIREN PIR SENSORS MM084 MM44 MAINS ADAPTOR DOOR CONTACTS Please note: Before you start to install this Micromark Alarm, we advise that you should take adequate safety precautions when using power tools
More informationInstallation & Programming Guide
Alert Version 8 Zone Control Arrowhead Alarm Products Ltd Installation & Programming Guide Proudly Designed and Manufactured in New Zealand Arrowhead Alarm Products Ltd PHONE: (09) 579 7506 FAX: (09) 579
More informationAuto Dialer. Manual E-921APQ E-921GPQ
Troubleshooting: Auto dialer will not arm/disarm Auto dialer will not dial out Unit doesn t respond to a call-back Difficulty in activating room monitor by telephone remote control Make sure that you have
More informationPRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit
PRODUCT INSTRUCTIONS Fire Door Control Panel (FDCP) Floats Rd, Wythenshawe, Manchester. M23 9WB T: 44 (0)161 945 4561 F: 44 (0)161 945 4566 Stock Code Description Doc No: PI115 00133 00134 Ellard Fire
More informationBENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice.
BENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice. via Florida - Z.I. Valtesino - 63013 GROTTAMMARE (AP) - ITALY USER MANUAL: Digital communicator
More informationAXS Strikemaster Engineering Manual
AXS Strikemaster AXS Strikemaster Programming and Operation Manual Jan 2014 Page 1 of 23 Table of Contents Important Note... 3 Features and Benefits... 3 Ordering Details... 4 Dimensions... 5 Installation...
More informationModel 17A00 Expansion Enclosure
HOME AUTOMATION, INC. Model 17A00 Expansion Enclosure Installation Manual Document Number 17I00-1 Rev A March, 2002 Home Automation, Inc. Model 17A00 Expansion Enclosure Installation Manual Document Number
More informationIntruder alarm system Operating Instructions
Intruder alarm system Operating Instructions 1 2 3 4 5 6 TA PA ZONE Learn Error AccentaG3 mini Servicing organisation details Servicing organisation (Installer) name: Telephone number: Date of installation:
More information