1 Quick Alert Remote (QA216R) Description The QA 216 Remote is used by AT&T to monitor tower lights and turned down facilities. It is a 16-bit alarm unit used to transport discrete alarms from a remote location to TMAS. The unit has visual indications to display standing alarms, dialing indicators and call-in indication. Overview Before a Quick Alert Remote can be put into operation, it must be: Physically connected to its power source, telephone line, and alarm inputs. Provided with information regarding its physical identification, communications options, alarm inputs and what to do when an alarm occurs. Note: For ease of programming, information should be gathered together in Table A before starting the configuration process. Fig. 1 - Quick Alert Remote is a 16-bit alarm unit used to transport discrete alarms from a remote location to TMAS. Table of Contents Application Shipping List Hardware Installation Software Installation Specifications Model Number Turn Up Procedures Troubleshooting Procedures Glossary D-PC A-00 1 OG-QAR-310

2 Fig. 2 - DPS Quick Alert Remote passes Quick Alert alarms back to TMAS Application Figure 2 is a simple block diagram showing the relationship between the Quick Alert Remotes (QA216R), the Osborne-Hoffman Receiver, the Quick Alert Processor, the NTP and other elements. Shipping List Your shipment should include the following items: QA 216 Remote unit AC Adapter, RJ-12 Cable, D-PR A-01 Power Cable, D-PR A-20 Mounting Hardware Mounting Template Operation Guide Screwdriver, D-PS A-00 Note: A DB9 cable will accompany software, if requested. Hardware Installation 1. Unpack Quick Alert Remote and all accessories. Check contents against enclosed shipping list. 2. Fill out and mail the postage prepaid registration card. 3. Mount the Quick Alert Remote. (Use enclosed mounting template and hardware.) 4. Connect up to 16 alarm points on the Quick Alert Remote. To operate an alarm point, a connection must be made between the alarm point and the QA216R ground (COM A-D). 5. Connect the RJ12 phone line to the Quick Alert Remote. (See Figure 4, for steps 5 through 7.) 6a. AC Power - Connect the power adapter to Power In on the Quick Alert Remote back panel. Then plug the adapter into an AC outlet. -or- 6b. DC Power - A DC supply may be connected to -PWR on the Quick Alert Remote barrier strip. (This arrangement is only suitable for V operation. It utilizes the fusing provided on the QA216 board.) 7. Proceed to Software Installation following completion of Table A. D-PC A-00 2 OG-QAR-310

3 2000 DPS Telecom MADE IN USA Alarm points 1-8 Common Alarm points 9-16 Tip/Ring Fig. 3 - DC Power and alarm ports are located on the front of the Quick Alert Remote. Power Power jack for AC Adaptor Phone line connection RJ-12 (see details below) RJ Ring 3 Tip 2 1 Craft port female DB9 (see details below) DTR GND TX RX Pin Signal Description 1 NC Not Connected TX Transmit Data 3 RX Receive Data 4 DTR Data Terminal Ready 5 GND Ground RTS CTS 6 NC Not Connected 7 CTS Clear To Send 8 RTS Request to Send NC Not Connected Tbl. A - Configuration Data (Fill In) Site Definition (refer to Help menu or Glossary for explanation of fields) Device name Ring Bypass Periodic Status Reporting Site Number Enabled: Enabled: Report Interval Reporting Phone Break: hhh: hhh: Site Phone Active: mm: mm: No. of Rings Rings: Alarm Number Fig. 4 - AC power and communication ports are located on the rear of the Quick Alert Remote Description Alarms Times to Repeat Qual Period Call when Clear Normally Closed D-PC A-00 3 OG-QAR-310

4 Fig. 5 - Define your Quick Alert Remote alarms and complete the configuration screen with the information you filled into Table A Note: The Quick Alert software is only applicable in selected installations. QA216R software runs under Windows 95, 98 or NT. Software Installation The QA216R program permits you to edit the information needed by the Remote unit and to write that information to internal memory. After configuration, the program can also be used to monitor a specific unit. The QA216R program and files will normally be located in a directory named Program Files\Tconfig\ Qa216r. (You can specify a different directory when you install QA216R.) All other DPS configuration programs and files will also be located in the Tconfig (or your specified) directory. Install QA216R 1. Place the QA216R disk in the A: drive. 2. Click on the Start button. Click Run. 3. The Installshield wizard will run. Follow the instructions on the screen. QA216R Setup 1. Start the program file by double clicking the QA216R icon in the Program Files\Tconfig\Qa216r directory (or the other directory which you chose during installation) 2. Enter your initials in the initials box. 3. The QA216R Site Definition box will appear with a Device Name: UNTITLED. 4. Use the information which you entered in Table A to fill in the fields of the Site Definition box. (Refer to Figure 5.) Writing Data to the Quick Alert Remote 1. Pull down the Connect Menu to make a connection to the Q A216 Remote using the selection: Serial Cable on COM2. Ensure that your computer s COM port is set to the same configuration. (Refer to Figure 9.) 2. Click on Connect to complete the connection between your computer and the QA 216 Remote. (Refer to Figure 10.) 3. Click on Write to QA 216 Remote to send the data to the device. Then click Done. (Refer to Figure 6.) Disconnecting from the QA216R 1. After your configuration data has been written to the device, you should disconnect and reconnect to allow the QA216R to re-initialize before use. 2. Click on the Disconnect button to go back to the QA216R configuration program. D-PC A-00 4 OG-QAR-310

5 Fig. 6 - Data has been written to the device memory when Transfer Complete appears in the Writing Properties dialog box Connecting to the QA216R Monitor 1. Click on Connect to complete the connection between your computer and the QA 216 Remote. (Refer to Figure 10.) 2. Click the Monitor button to check on the status of the alarms. Use the scroll bar on the right side to view the second set of 8 alarms. Alarms show in RED. Clear shows in GREEN. Qualifying shows in YELLOW. 3. Alarms can be ACKed from this screen as well. (Refer to Figure 11.) Reading Data from the QA216R 1. Once you are connected to the Quick Alert 216 Remote, you can read the data from the device memory by clicking on the Read button. 2. Clicking the Done button returns you to the main screen. (Refer to Figure 7.) Viewing the QA216R Data Flow 1. Clicking the Display Protocol button brings up a window showing the actual traffic between the computer and the device. This traffic flow view is primarily for diagnostic purposes. (Refer to Figure 8.) 2. The display can be paused or cleared by clicking the appropriate buttons. 3. Click the Exit button to return to the main screen. Fig. 7 - Data has been read to the device memory when Transfer Complete appears in the Reading Properties dialog box Fig. 8 - Data flow between computer and QA 216 Remote can be viewed in the Protocol display window D-PC A-00 5 OG-QAR-310

6 Fig. 9 - COM port settings Specifications Dimensions: 8 (W) X 7 (L) X 1.5 (H) Mounting: Keyhole pattern on the back allows mounting on a wall, frame or rack panel. Power Input: -24 DC unit: -18 to ma Fuse: Temperature Range: 1/2 Amp for QAP C Humidity: 0% to 95% non-condensing Interface: 1 RS232 (DB9) Craft Port and 1 RJ12 telephone line port on the rear, Alarm Points: 16 discrete Ground Points: 4 screw down Model Number D-PC A-00 QA 216 Remote Fig At this point you can Read, Write or Monitor Fig After configuration/downloading, you can connect to and monitor the status of your alarm points. D-PC A-00 6 OG-QAR-310

7 Turn Up Procedures The QA 216 Remote has visual indications to display standing alarms, dialing indicators and call-in indication. AC power via the AC transformer can be connected with the module connector provided to the power connector (top) or by connecting to the battery terminal on the front of the board marked AC/DC power. Telephone line access is provided by either the RJ connector (top) or by the wire connection on the front of the unit. Currently, due to database restrictions, only 11 external alarms can be connected to the QA216R remote unit. QA ON BATTERY, will be transmitted by the QA unit when AC is lost at the AC receptacle. (Alarm transmitted Internal to the QA unit.) LO BATTERY will be transmitted by the QA unit when voltage drops to approximately (Alarm transmitted Internal to the QA unit.) Note: DO NOT CONNECT 120 VOLTS AC DIRECT- LY TO THE UNIT. Tools Required 1. Phillips Screwdriver 2. Slotted Screwdriver 3. Wire Cutter/Stripper 4. Volt Meter Note: See shipping list on page two for equipment furnished. Installation Instructions Call a day or so before installation to ensure someone will be available to work with you and to ensure TMAS database is in place. 1. Install QA216R on Wall or Column near an AC outlet if possible. 2. Install the Surge Protector across the phone line as far from the QA as possible. 3. Connect Alarm leads (see Figure 12). a. Alarm 1...OPEN DOOR b. Alarm 2...RECTIFIER FAIL -48V c. Alarm 3...HIGH VOLT -48V d. Alarm 4...BATTERY ON DISCHARGE -48V e. Alarm 5...HIGH ROOM TEMP f. Alarm 6... LIGHTING PROTECTION FAIL g. Alarm 7...COMMERICAL AC PWR FAIL Each of the above alarm leads will require a return to the common terminal strip. All common terminals are strapped together. Multiple wires can be connected to the common terminal strip. QA216R 4. Remove the six screws and remove cover. 5. Connect Battery connector to circuit board connector (white connectors) 6. Reinstall cover and screws. 7. Connect AC power assembly leads to AC transformer and QA unit (see Figure 12). 8. Plug transformer in to AC outlet. 9. Connect telephone line to unit (see Figure 12). 10. Programming of the unit will be done remotely. 11. Call to have database downloaded to the QA unit. Verify communication to the unit and that the unit is reporting properly. 12. Installer will then be directed to call TMAS database to verify each of the environmental alarms to ensure they are reporting properly. 13. Installation and testing procedure complete. Troubleshooting Procedures 1. Unit does not report to base unit during the 24 hour period. QUICK ALERT FAIL TO TEST A. Dispatch is required to site (see Figure 13). B. Check for incoming dial tone. 1. Connect Butt Set or other listening device to phone terminals on front of unit. Wire pig tails could be installed for ease of connection. 2. If no dial tone or noisy, verify incoming to building if possible. If phone line is in trouble, the OSWF is to report trouble to Local Company. 3. If dial tone is present call for assistance. C. Check AC power 1. Check AC outlet where Transformer is plugged into for 120 volts AC 2. Check for 16 volts +/- 1 volt AC at power terminals on front of unit. 3. If voltage is not present, remove cover and check fuse. If unit is not reporting alarms... D. Check Zone Alarms 1. Check for any loose connections or broken wires. 2. Check voltages (see Figure 13). If unit is still inoperative... Call , prompt 7 (24-hour coverage) or Burlie Peiser Telemetry SME D-PC A-00 7 OG-QAR-310

8 TO TELEPHONE LINE RJ Connector Not Used In field Phone Connection AC Transformer Connection. OFF ON COM LINE Alarm 1.9 Alarm 2.10 Alarm 3.11 Alarm 4.12 Alarm 5.13 Alarm 6.14 Alarm 7.15 Alarm 8.16 Lo Batt AC Fail Fuse under cover 500 ma buzz QA 216 REMOTE Site Monitor DPS TELECOM Option: 2 Wire Phone can be connected to this terminal Power in V AC/DC Power in V AC/DC STANDARD ALARM LIST Alarm 1 OPEN DOOR Alarm 2 RECTIFIER FAIL -48V Alarm 3 HIGH VOLT -48V Alarm 4 BATTERY ON DISCHARGE 48V Alarm 5 HIGH ROOM TEMP Alarm 6.. LIGHTING PROTECTION FAIL Alarm 7 COMERICAL AC PWR FAIL Option: AC Transformer can be connected to wire connector block. ALARM COMMON All Common lugs are multipliable together NOT USED T R WIRE PHONE CONNECTION - + AC/DC POWER Each Alarm Dry Contact Wiring to Alarmed Equipment AC TRANSFORMER (Connect to 120 Volts AC only) ATTACHMENT A QUICK ALERT REMOTE UNIT QA 216 REMOTE DPS TELECOM 6/19/00 BEP 1 Fig Alarm leads require a return to the common terminal strip. D-PC A-00 8 OG-QAR-310

9 TO TELEPHONE LINE Not Used In field RJ Connector Phone Connection AC Transformer Connection. OFF Alarm 1.9 Alarm 2.10 Alarm 3.11 Alarm 4.12 Alarm 5.13 Alarm 6.14 Alarm 8.16 Lo Batt AC Fail ALARM ON Alarm 7.15 COMMON All Common lugs are multipliable together COM Fuse under cover 500 ma buzz NOT USED Wiring to Alarmed Equipment LINE QA 216 REMOTE Site Monitor DPS TELECOM 48 V DC T R WIRE PHONE CONNECTION Dry Contact Power in V AC/DC 16 V AC +/- 1 volt - + AC/DC POWER Option: AC Transformer can be connected to wire connector block. AC TRANSFORMER (Connect to AC 120 volts only) Butt Set to test for dial tone & Monitor Dial Pulses DC VOLTS VOLT + METER - Verification of Standing Alarms: Connect DC Volt Meter + to Alarm to be tested. Connect DC Volt Meter - to any Comm lug. No Alarm standing = 13.0 volts Alarm Standing = 0.0 volts AC power can be check at these terminals for the /- 1 volt. ATTACHMENT B QA 216 REMOTE ALARM VERIFICATION TEST DPS TELECOM Fig Use a voltage meter to troubleshoot if the unit does not report to the base unit 6/19/00 BEP 2 D-PC A-00 9 OG-QAR-310

10 Glossary Note: The following data explain your choices in filling out Table A. Alarm Number: predefined value 1 to 16 used throughout the system to identify a particular alarm. Call when Clear: check if users are to be notified when an alarm clears. Connect Menu:This selection will connect you to the subject QA216R to allow you to first transfer the configuration and then to operate and control the device locally. Delete Device: this item, under the File menu, is available only when the current system record was retrieved from disk using Open Device. It deletes the disk record and blanks the current system record. Description: up to 30 characters. Leave blank if no alarm defined. Exit: this item, under the File menu, closes the QA216 program. Help Menu: This program is equipped with an extensive help system which can be used to help you to understand, configure and monitor the device. New Device: this item, under the File menu, initializes a blank device record with the default name UNTITLED. This becomes the current system record. It may be assigned a name by doing a Save Device As, which renames the current system record and saves it to disk. Normally Closed: alarms are essentially detected as changes in the position of a switch. The QA216 assumes that conditions are normal when a switch is open and triggers an alarm when it closes. In some applications this is reversed and the alarm occurs when the switch opens. Check Normally Closed if you have any alarms that are wired up this way. Number of Rings: how many rings the QA216 will wait before answering a call, usually 2. This may be increased to as many as 15 if, for instance, the QA216 is sharing a voice line and you want to give personnel a chance to pick up before the device does. Open Device: this item, under the File menu, retrieves a device record which was previously saved in.dbf format. Periodic Status Reporting: Periodic Status Reports are pages that are routinely issued at a fixed time interval to selected pager users, indicating the current state of all alarms. Check Periodic Status - Enabled to generate such reports. Phone Number Reporting To: the number the QA216 will dial to report alarms. Print: this item, under the File menu, produces a listing of device properties for selected devices. Qualification Period: time period that an alarm must be active before the QA216 will consider it to be valid and reportable. Range and resolution depends upon the Qualification Period Base Time. If the base time is Tenths of Seconds, range is zero to 6 minutes to the nearest tenth of a second. If the base time is Seconds, range is zero to 1 hour to the nearest second. If the base time is Minutes, range is zero to 60 hours to the nearest minute. D-PC A OG-QAR-310

11 Qualification Period Base Time: the base unit for expressing Qualification Periods. The range and resolution of Qualification Periods for individual alarms depends upon this value. If the base time is Tenths of Seconds, range is zero to 6 minutes to the nearest tenth of a second. If the base time is Seconds, range is zero to 1 hour to the nearest second. If the base time is Minutes, range is zero to 60 hours to the nearest minute. Reindex: This command allows you to rebuild the database index and it may cure the problem of a scrambled or missing database Report Interval: the period between Periodic Status Reports, 15 minutes to 255 hours 59 minutes. Timing starts at the moment that device parameters are written to the QA216. Ring Bypass/Active Rings: provides a capability for a QA216 to share its phone line with another device such as an answering machine. When incoming calls are detected, if a break between rings of at least BREAK seconds is observed, the QA216 will open a Bypass Window that is ACTIVE seconds long. If a number of rings equal to RINGS is received while the bypass window is active, the QA216 will answer. Example: QA216 shares phone line with answering machine set to pick up after 4 rings. Set QA216 NUMBER OF RINGS to 6, BYPASS BREAK to 10 seconds, BYPASS ACTIVE to 30 seconds, and BYPASS RINGS to 2. If a single call with uninterrupted ringing is received, the answering machine will pick up on the 4th ring. (If the answering machine is off, the QA216 will answer on the 6th ring). To reach the QA216, dial the number, hang up after 3 rings, wait a little more than 10 seconds, then dial again within 30 seconds. The QA216 will answer on the second ring. Save Device: this item, under the File menu, is available only when the current system record was retrieved from disk using Open Device. It writes the current system record back to the same directory path and device name where it originated. Save Device As: this item, under the File menu, saves the current system record to disk after permitting a new directory path and device name to be specified. Site Number: numeric value used to identify a particular QA216 Remote device. Site Phone: the number dialed to call in to the QA216 Remote device. Times to Repeat: the number of times to retry the alarm reporting cycle if an ack is not received. D-PC A OG-QAR-310

12 DPS Telecom Your Partners in Telecom Management Networks Visit our website at dpstele.com 4955 East Yale Avenue, Fresno, California Fax OG-QAR-310 9/27/00

User Manual DPM 208. Alarm and Control Network Element. Um119889

User Manual DPM 208. Alarm and Control Network Element. Um119889 User Manual DPM 208 Alarm and Control Network Element Um119889 DPM 208 Version 1.0B Alarm and Control Network Element Publication Number UM119889 Date of issue: 8-31-99 4955 E. Yale Ave. Fresno, CA 93727

More information

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM Alarm Panel USER MANUAL [ PRELIMINARY HARDWARE MANUAL ] Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. May 7, 2008 D-OC-UM085.07010 v1.0a Revision History April 28, 2008 May

More information

FCD-wire Contents. List of Figures

FCD-wire Contents. List of Figures FCD-wire Contents FCD-X21 Configuration 1 Introduction... 1 2 Opening the FCD Application... 1 3 FCD Window... 2 4 FCD LEDs... 3 5 Configuration Operations... 4 FCD Info...4 FCD System Info...5 FCD Interface

More information

Contents. Glossary

Contents. Glossary Contents Glossary ------------------------------------------------------------------------------------------------------ 6 1. Introduction to the IDS 1632 -------------------------------------------------------------

More information

GLOBAL. InstallatIon & operation manual

GLOBAL. InstallatIon & operation manual InstallatIon & operation manual INDEX 1. INTRODUCTION... 5 2. FEATURES AND FUNCTIONS 2.1 Reporting Options... 2.2 Interfaces... 2.3 Programming... 2.4 Indicators and Controls...... 6 6 6 6 6 3. INSTALLATION...

More information

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor A1UL PERS Personal Emergency Response System TABLE OF CONTENTS 1. READ THIS FIRST... 1 2. SYSTEM OVERVIEW.. 1 3. COMPONENTS 2 4. UNIT OPERATION! Standby Mode.. 3! Emergency Activation. 3! Answering Incoming

More information

rvm4c Installation Guide Remote Video Module

rvm4c Installation Guide Remote Video Module rvm4c EN Installation Guide Remote Video Module rvm4c Installation Guide Installation Diagrams EN 2 Installation Diagrams for the Transmitting Unit rvm4c Installation Guide Basic Hardware Installation

More information

Added password for IP setup page : Password must be in IP format!

Added password for IP setup page : Password must be in IP format! NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP

More information

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL ap15_2manual04/22/13 Page 1 4/22/2013 1 Serial Number : Option: OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL Micro Seven, Inc. 1095-K N.E. 25th Hillsboro, OR 97124 U.S.A. phone: 503-693-6982

More information

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document 70072-0125-01 TECHNICAL NOTE NOVEMBER 2006 ION Meter Alerts A PowerLogic ION meter can send alerts to indicate a user specified power system condition such as a power quality problem (including surges,

More information

User Manual. Dryer Controller M720

User Manual. Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009

More information

Computer Room Guard Model VM Manual and Installation Instructions

Computer Room Guard Model VM Manual and Installation Instructions Computer Room Guard Model VM500-8 Manual and Installation Instructions For units purchased since December 2004 Index Page General Description 3 Installation, Wiring Diagram 3-5 Accessing the Computer Room

More information

Manage Alarms. Before You Begin CHAPTER

Manage Alarms. Before You Begin CHAPTER CHAPTER 8 Manage Alarms This chapter contains the procedures for viewing and managing the alarms and conditions on a Cisco ONS 15454. Cisco Transport Controller (CTC) detects and reports alarms generated

More information

Dryer Controller M720

Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,

More information

Security System. User Guide for the LED Command Center

Security System. User Guide for the LED Command Center Security System User Guide for the LED Command Center National Security Systems Inc (800)457-1999 MY SECURITY COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY

More information

Dry Contact Probe DCP (#30008)

Dry Contact Probe DCP (#30008) Dry Contact Probe DCP (#30008) The Networked Robotics DCP probe enables network data collection of the state of any normally open or normally closed switch. This product can sense alarm contact outputs

More information

DPM & DPM-216 USER MANUAL. May 21, Firmware Version - DPM: 2.1I Firmware Version - DPM216: 1.0A D-OC-UM

DPM & DPM-216 USER MANUAL. May 21, Firmware Version - DPM: 2.1I Firmware Version - DPM216: 1.0A D-OC-UM DPM & DPM-216 USER MANUAL May 21, 2009 D-OC-UM09.521200 Firmware Version - DPM: 2.1I Firmware Version - DPM216: 1.0A Revision History May 21, 2009 Released updated D-OC-UM09.521200 March 12, 2009 Released

More information

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual Instruction manual MTL process alarm equipment October 2016 CSM 725B rev 2 MTL RTK 725B Configuration Software Manual SECTION 1 - INTRODUCTION... 5 Basic Requirements... 5 SECTION 2 - SOFTWARE INSTALLATION...

More information

Monitoring Operator Guide. Access Control Manager Software Version

Monitoring Operator Guide. Access Control Manager Software Version Monitoring Operator Guide Access Control Manager Software Version 5.10.10 2018, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACCESS CONTROL MANAGER, ACM, ACM VERIFY AND TRUSTED

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS The SensorNet I/O Module provides attachment for up to 32 alarms and up to 16 switched devices. An RS-232 or RS-422 communications port is also provided for receiving serial alarms.

More information

FreezeAlarm Dialer Pro

FreezeAlarm Dialer Pro FreezeAlarm Dialer Pro User Manual for FA-800E Thank you for purchasing our FreezeAlarm Dialer Pro. This instruction manual covers installation for model FA-800E. General Description The FA-800E automatically

More information

WeatherLink for Alarm Output Addendum

WeatherLink for Alarm Output Addendum WeatherLink for Alarm Output Addendum Introduction This Streaming Data Logger is designed to provide an electrical interface between a Vantage Pro or Vantage Pro2 weather station console or Weather Envoy

More information

IRIS Touch Firmware Enhancements and Additions from Version to Version

IRIS Touch Firmware Enhancements and Additions from Version to Version Overview IRIS Touch Firmware Enhancements and Additions from Version 1.14.3 to Version 1.19.1 This document details enhancements to the feature set of the IRIS Touch from firmware Version 1.14.3 to Version

More information

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems Honeywell Life Safety Iberia C/Pau Vila 15-19; 08911 Badalona Barcelona T. 902 03 05 45; Internacional:+34932424236 www.honeywelllifesafety.es infohlsiberia@honeywell.com ibox Modbus Server Gateway for

More information

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm Operating & Maintenance Manual Alert-4 Ethernet LCD Master Alarm w w w. a m i c o. c o m Contents User Responsibility 4 Introduction 4 Features 5 Description of the Alarm 5 Shipment Details 5 The Alarm

More information

PBI Manual. Paradox to KNX-BUS Interface

PBI Manual. Paradox to KNX-BUS Interface PBI 64-192 Paradox to KNX-BUS Interface Manual GDS Intelligence in Buildings El. Benizelou 116 Nea Erithrea, 14671 Phone: +30 2108071288 Email: info@gds.com.gr Web: gds.com.gr Contents 1 Device description...

More information

Manage Alarms. Before You Begin CHAPTER

Manage Alarms. Before You Begin CHAPTER CHAPTER 9 Manage Alarms This chapter contains the procedures for viewing and managing the alarms and conditions on a Cisco ONS 15454 SDH. Cisco Transport Controller (CTC) detects and reports SDH alarms

More information

Before you install ProSeries Express Edition software for network use

Before you install ProSeries Express Edition software for network use Before you install ProSeries Express Edition software for network use The following pages describe system requirements and other information you need to know before installing ProSeries Express Edition

More information

CBI-064. User Manual. Caddx to KNX-BUS Interface

CBI-064. User Manual. Caddx to KNX-BUS Interface CBI-064 Caddx to KNX-BUS Interface User Manual GDS Intelligence in Buildings El. Venizelou 116 Nea Erithrea 14671 Tel: +30 2108071288 Email: info@gds.com.gr Web: gds.com.gr Contents 1 Device Description...

More information

Table of Contents. Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4. Part III Safety Messages 13

Table of Contents. Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4. Part III Safety Messages 13 Manual I SS2000 TouchScreen Installation Guide Table of Contents Foreword 0 Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4 1 Installing the... SS2000 TouchScreen

More information

FIRERAY 5000 range USER GUIDE

FIRERAY 5000 range USER GUIDE FIRERAY 5000 range USER GUIDE 0044-003-04 IMPORTANT PLEASE NOTE: The beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal.

More information

ALARM SYSTEM USER S MANUAL Rev

ALARM SYSTEM USER S MANUAL Rev ALARM SYSTEM USER S MANUAL Rev.06 890-00011 Manufacturer: Viatron Electronics 3514 1st Street, St-Hubert (Quebec) Canada J3Y 8Y5 WARNINGS the warranty can be void if the Agri-Alert 2400 is used in a manner

More information

Agri-Alert 800 EZe Alarm System Owner s manual

Agri-Alert 800 EZe Alarm System Owner s manual Agri-Alert 800 EZe Alarm System Owner s manual Read this guide carefully before using the alarm system. Manufacturer: Viatron Electronics 5200, Armand-Frappier St-Hubert (Quebec) Canada J3Z 1G5 WARNINGS

More information

OUT TO WALLJACK. Input

OUT TO WALLJACK. Input Innovative Technologies in Custom Electronic Design & Manufacturing Thank you for purchasing our Intermediate FreezeAlarm, model FA-I. The FreezeAlarm Intermediate model will automatically call up to three

More information

OVEN INDUSTRIES, INC.

OVEN INDUSTRIES, INC. OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and

More information

2000 Series. Program Entry Guide. Control Panels

2000 Series. Program Entry Guide. Control Panels 2000 Series EN Program Entry Guide Control Panels 2000 Series Program Entry Guide About This Manual EN 2 About This Manual This guide describes the programming parameters available to the 2000 Series Control

More information

Security System. User s Guide for the Text Command Center

Security System. User s Guide for the Text Command Center User s Guide for the Text Command Center MY ALARM COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY CONTROL PANEL IS CONNECTED TO THE PHONE JACK LOCATED:

More information

Mark 25 Ultrapure Water Conductivity Analyzer

Mark 25 Ultrapure Water Conductivity Analyzer Martek Instruments, Inc. Mark 25 Ultrapure Water Conductivity Analyzer Instruction Manual WARRANTY POLICY Unless otherwise stated, MARTEK INSTRUMENTS, INC. warrants this equipment to be free from defects

More information

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005) RC801/803/805-480B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005) 1. Cautions Please read the following notices carefully before installing and using the device,

More information

Interrogator 200 Audio Verification Module (AVM)

Interrogator 200 Audio Verification Module (AVM) Interrogator 200 Audio Verification Module (AVM) Document Number: 466-1153 Rev. B July 1996 Audio Verification Module Use a maximum of 500 feet of cable for all speakers and microphones. For example, if

More information

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone! Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone! GSM SMS Controller DCS-130 User Manual Ver 1.20 Date Issued: 14-9-2010

More information

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n SW version 5.n PORTAL USER MANUAL Mobeye WaterGuard-FS Float sensor CM2300FS Attention! Very important This user manual contains important guidelines for the installation and usage of the Mobeye device

More information

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160 All-In-One Wireless Security System V3.2 Programming Guide Model # MG6130 / MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL

AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL M 890-00279 rev. 14 K 895-00004 rev. 00 Manufacturer: Viatron Electronics 5200, Armand-Frappier St-Hubert (Quebec) Canada J3Z 1G5 WARNINGS The warranty can be void

More information

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide Grandstream Networks, Inc. Table of Contents INTRODUCTION... 4 GDS3710 WIRING CONNECTION... 5 Powering and Connecting the GDS3710... 5 Power and Data PINs... 5 Alarm In and Alarm Out PINs... 6 DETECT AND

More information

ADE Gen4. Speech Dialler Engineering Information. Description. Features

ADE Gen4. Speech Dialler Engineering Information. Description. Features ADE Gen4 Speech Dialler Engineering Information Description The Informa is a Speech Dialler for use with intruder alarm systems. When the control panel recognises an alarm it triggers the Informa. The

More information

Refrigerator/Freezer Guard Models VM605, VM605E. Property Guard Models VM610, VM610E. Temperature Monitor and Alarm

Refrigerator/Freezer Guard Models VM605, VM605E. Property Guard Models VM610, VM610E. Temperature Monitor and Alarm Refrigerator/Freezer Guard Models VM605, VM605E Property Guard Models VM610, VM610E Temperature Monitor and Alarm Microtechnologies, Inc. www.temperatureguard.com sales@temperatureguard.com support@temperatureguard.com

More information

Grandstream Networks, Inc. GDS3710 Input/output Alarms Configuration Guide

Grandstream Networks, Inc. GDS3710 Input/output Alarms Configuration Guide Grandstream Networks, Inc. Table of Contents INTRODUCTION... 4 GDS3710 WIRING CONNECTION... 5 Powering GDS3710... 5 Power and Data PINs... 5 Connecting Alarm IN and Alarm OUT PINs... 6 Alarm IN Connection

More information

Smart Combiners Installation Guide. For Obvius A89DC-08 sensor modules

Smart Combiners Installation Guide. For Obvius A89DC-08 sensor modules For Obvius A89DC-08 sensor modules Introduction Large roof and ground arrays connect the panels into stings that are merged together in combiner boxes. Each string will typically consist of 10-15 panels

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TT-1343 5/06b INSTALLATION INSTRUCTIONS Original Issue Date: 8/03 Model: Automatic Transfer Switches Equipped with Series 1000 Programmable Controller Market: ATS Subject: Remote Annunciator Kits GM28938-KP1,

More information

System. For a better understanding of this product, please read this user manual thoroughly before using it.

System. For a better understanding of this product, please read this user manual thoroughly before using it. GSM Alarm System User s Manual For a better understanding of this product, please read this user manual thoroughly before using it. Chapter 1. Features Chapter 2. Control Panel Introduction Chapter 3.

More information

SC-F3G User Manual 1.0

SC-F3G User Manual 1.0 SC-F3G User Manual 1.0 Table of Contents 1. Introduction... 3 2. Functions... 3 3. Features... 3 4. Package Contents... 3 5. Device Configuration... 4 6. Status LED signals... 5 7. Before You Start...

More information

BOSCH GV4 Alarm Panel

BOSCH GV4 Alarm Panel System Galaxy Quick Guide CONFIGURATION AND OPERATION BOSCH GV4 Alarm Panel SG 10.2 (or later) NOV 2012 This is a Galaxy Product Interface Guide. Information in this document is subject to change without

More information

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder Pipo Communications Model ST-888 DTMF ANI/ENI Display Decoder 1516 Cassil Place Hollywood, California 90028-7106 Phone: 323-466-5444 Fax: 323-466-1520 www.pipo.cc Manual # 68-9888 May 1, 2002 Rev. 5/02

More information

Exercise 8. Controlling a Batch Mixing Process EXERCISE OBJECTIVE

Exercise 8. Controlling a Batch Mixing Process EXERCISE OBJECTIVE Exercise 8 Controlling a Batch Mixing Process EXERCISE OBJECTIVE To create a ladder program for controlling a batch mixing process. To test program operation through the completion of verification steps.

More information

Specification for On-Line UPS Battery Monitoring and Data Management System

Specification for On-Line UPS Battery Monitoring and Data Management System 1 Scope This specification defines the minimum requirements for a predictive on-line Battery Monitoring BMDMS with test, analysis, and remote monitoring control capabilities. Unless noted otherwise, the

More information

Agri-Alert 800EZe. Alarm System. Alarm. System in Standby. Burglary Armed. Online (phone) Green = zone activated Amber = zone bypassed.

Agri-Alert 800EZe. Alarm System. Alarm. System in Standby. Burglary Armed. Online (phone) Green = zone activated Amber = zone bypassed. Agri-Alert 800EZe Alarm System User s Manual Alarm System in Standby Burglary Armed 1 2 ZONES 5 6 Online (phone) 3 7 4 8 Green = zone activated Amber = zone bypassed ZONE LIGHTS LEGEND Red = zone in alarm

More information

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System MOBILE CALL GSM Alarm System GSM Alarm System System disarmed 11/26/2013 User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. CONTENTS

More information

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power! Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power! Centroid Snet 2 Battery Management Software User Manual V1.1 www.eepowersolutions.com Tel: 1-877-805-3377 info@eepowersolutions.com

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Minimum lighting control (base scope of work) shall include all corridors. The lighting in all the corridors shall be turned on (if not already on) if

More information

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE isocket Smart Relay is a complex Smart House system which is installed in the fuse cabinet (electric cabinet) in the house. We therefore assume that

More information

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System MOBILE CALL GSM Alarm System USER S MANUAL System disarmed 00/00/00 00:00 ARM STAY CALL 1 2 3 4 5 6 7 8 9 Power Set Signal Alarm SOS ESC 0 ENTER Profile For a better understanding of this product, please

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

Discrete Point Module (DPM) 216 G2

Discrete Point Module (DPM) 216 G2 Discrete Point Module (DPM) 26 G2 USER MANUAL Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. December 8, 200 D-OC-UM0C.800 Firmware Version.0A Revision History May 27, 20 Misc

More information

FreezeAlarm. General Description FA-D /FA-D-AAB. Applications. Features. Specifications. Dimensions

FreezeAlarm. General Description FA-D /FA-D-AAB. Applications. Features. Specifications. Dimensions Innovative Technologies in Custom Electronic Design & Manufacturing General Description The FA-D (fahrenheit) and FA-D-AAB (celsius) FreezeAlarm monitors temperature, power status, security or an external

More information

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure. Notice The material and instructions covered in this manual have been carefully checked for accuracy and are presumed to be reliable. However, Radionics, Inc. assumes no responsibility for inaccuracies

More information

1. User features of the GSM dialer

1. User features of the GSM dialer 1. User features of the GSM dialer The JA60GSM dialer offers many useful features described in detail below. The installer should properly demonstrate the use of the system to the user after installation

More information

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D ASCO 5350 The ASCO 5350 ATS Remote Annunciator is listed under the Underwriter s Laboratories Standard UL-1008 for Automatic Transfer Switch accessories. This stand-alone device provides individual status

More information

GPS Evaluation Kit EVA1037/1080

GPS Evaluation Kit EVA1037/1080 GPS Evaluation Kit An evaluation system for Tyco Electronics GPS modules A1037-A & A1080-A User s Manual Version 2.0 Hardware Revision 01 This page was intentionally left blank. Revision History Revision

More information

Installing ProSeries software for stand-alone use

Installing ProSeries software for stand-alone use Welcome to ProSeries tax software For information about this topic... Look here... Getting ready Page 1 Installing ProSeries software for stand-alone use Page 1 Setting up the ProSeries program Page 3

More information

USER MANUAL FOR OPERATING SYSTEM

USER MANUAL FOR OPERATING SYSTEM P2262 ALARM PANEL USER MANUAL FOR OPERATING SYSTEM 21765-07 September 1999 Associated Controls (Aust) PTY. LTD. 29 Smith Street, Hillsdale, NSW, 2036. PH (02) 9311 3255, FAX (02) 9311 3779 Page 1 of 177

More information

HOME AUTOMATION, INC. Lumina and Lumina Pro Lighting and Automation System. Quick-Start Installation Guide

HOME AUTOMATION, INC. Lumina and Lumina Pro Lighting and Automation System. Quick-Start Installation Guide HOME AUTOMATION, INC. Lumina and Lumina Pro Lighting and Automation System Quick-Start Installation Guide Document Number 44I00-1 Rev. 2.12 February, 2006 For complete operation and programming instructions,

More information

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL The LeakMonitor alarm panel is a microprocessor controlled fully adjustable alarm system suitable for multizone

More information

Memcom Emergency Telephone

Memcom Emergency Telephone Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming

More information

Omniguard 4: Features

Omniguard 4: Features OMNIGUARD 4 The clear choice for monitoring and documenting Vacuum and Pressure in a containment area. Ideal for Asbestos, Lead and Mold abatement and Clean Room monitoring. Omniguard 4: Features The Omniguard

More information

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual RC802/804-240B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005) 1. Cautions Please read the following notices carefully before installing and using the device,

More information

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX Page 1 of 10 Model 10807800 January 2014 ACCURATE ELECTRONICS INC PO BOX 1654 97075-1654 8687 SW HALL BLVD 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 WWW.ACCURATE.ORG Practice Section 10807800

More information

Program version Alarm Control Panels PROGRAMMING GDAŃSK. versa_p_en 03/09

Program version Alarm Control Panels PROGRAMMING GDAŃSK. versa_p_en 03/09 Alarm Control Panels Program version 1.00 PROGRAMMING GDAŃSK versa_p_en 03/09 The SATEL's goal is to continually upgrade the quality of its products, which may result in alterations of their technical

More information

Setup & Operation Index

Setup & Operation Index SENTRY PreSTAT SIMPLEX PANEL Installation and Operation Manual Environment One Corporation Setup & Operation Index Setup & Operation Index...2 Sentry PreSTAT Menu Flowchart...3 Overview...3 Wiring Instructions...5

More information

IP & SMS Alarm Communicator

IP & SMS Alarm Communicator Models: WGSMSC You deserve to feel safe, secure & protected IP & SMS Alarm Communicator Quick Start Guide Thank you for purchasing a Watchguard IP & SMS Alarm Communicator This Quick Start Guide covers

More information

Installation & Operation Manual March 2017 Rev. 4.1

Installation & Operation Manual March 2017 Rev. 4.1 Installation & Operation Manual March 2017 Rev. 4.1 #200, 550 71 st Avenue SE Phone: (403) 255-9544 Calgary, Alberta, Canada Fax: (403) 259-2343 T2H 0S6 www.barnettprotalk.com email: sales@barnettprotalk.com

More information

Patriot Systems Limited

Patriot Systems Limited COPYRIGHT 1997 - The Patriot Systems Ltd. Patriot Alarm Monitoring Automation Package is licensed for use on one computer, by the original person, or company, or organization whose name is registered with

More information

PERMACONN PM1030 Includes DI300. Installation Manual

PERMACONN PM1030 Includes DI300. Installation Manual PERMACONN PM1030 Includes DI300 Installation Manual Radio Data Comms Unit 5/20-30 Stubbs Street Silverwater NSW 2128 Telephone: 02 9352 1777 Facsimile: 02 9352 1700 Introduction The PERMACONN system provides

More information

Version 1.03 January-2002 USER S MANUAL

Version 1.03 January-2002 USER S MANUAL Version 1.03 January-2002 1 USER S MANUAL 2 Version 1.03 January-2002 System Details CUSTOMER:...... PHONE:... FAX:... INSTALLED BY:...... PHONE:... FAX:... MAINTENANCE & SERVICE:...... PHONE:... FAX:...

More information

Configuration and Operation Manual for the Unipos

Configuration and Operation Manual for the Unipos AxxonSoft Configuration and Operation Manual for the Unipos Integration Module Version 1.1 Moscow 2010 Contents CONTENTS... 2 1 LIST OF TERMS... 4 2 INTRODUCTION... 6 2.1 Document purpose... 6 2.2 Purpose

More information

Laptop / PC Programming Manual

Laptop / PC Programming Manual Laptop / PC Programming Manual Doc. # Fire PC Program rev B 01.07 This Document is property of Evax Systems, Inc. The Evax Fire Solutions Programmer Components 2 1.0 System Setup 4 1.1 Interface Setup

More information

C&K Software What s New. Commander II Version 3.0 Monitor II Version 3.0 Satellite II Version 1.0

C&K Software What s New. Commander II Version 3.0 Monitor II Version 3.0 Satellite II Version 1.0 C&K Software What s New Commander II Version 3.0 Monitor II Version 3.0 Satellite II Version 1.0 C&K Software PC-based receiver with monitoring features Windows-based Remote programming software (Commander

More information

GSM Smart Home Alarm Apparatus. [99+4 defense zones] Instruction for Use

GSM Smart Home Alarm Apparatus. [99+4 defense zones] Instruction for Use GSM Smart Home Alarm Apparatus [99+4 defense zones] Instruction for Use Table of content Ⅰ. Introduction to the system... 2 Ⅱ. Introduction to function... 2 Ⅲ. System composition and use method... 3 Ⅳ.

More information

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.goodforgas.com GfG Products for Increased Safety Congratulations

More information

Avigilon Control Center System Integration Guide

Avigilon Control Center System Integration Guide Avigilon Control Center System Integration Guide with Gallagher Command Centre INT-CARDAX-C-Rev3 Copyright 2013 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation

More information

Pump-Up Controller MODEL 4062

Pump-Up Controller MODEL 4062 Pump-Up Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4062 Pump-Up

More information

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH CONTROL PANEL INTERFACE USING THE AUTO/OFF/MANUAL SWITCH With the switch set to AUTO, the engine may crank and start at any time without warning. Such automatic starting occurs when utility power source

More information

Watchguard WGAP864 User Manual

Watchguard WGAP864 User Manual Watchguard WGAP864 User Manual v1.0 Issued September 2016 1 2 Table of Contents Glossary... 5 1. Introduction to your Watchguard WGAP864... 6 2. Before Operating your Alarm System... 6 3. Understanding

More information

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

DigiAir QUICK GUIDE & INSTRUCTION MANUAL DigiAir QUICK GUIDE & INSTRUCTION MANUAL The most trusted brand in Alarm Signalling www.csldual.com @CSLDualCom CSL DualCom Limited Figure 1 - DigiAir Yellow Comms LED Red Fault LED Yellow Service LED

More information

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET Instruction Manual Model 1582-125L 1:1 Switch February 2017, Rev. 0 CH1 HISTORY LINE HISTORY RESET AUTO MANUAL SELECT CH2 HISTORY LINE RESET MANUAL REMOTE AUTO PS1 PS2 MODEL 1582 CROSS TECHNOLOGIES INC.

More information

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0 IRIS Touch Quick Installation & Maintenance Guide Version 1.0 Page 2 of 16 IRIS Touch Quick Installation & Maintenance Guide Version 1.0 Contents 1. Introduction...4 2. Product Features...4 3. Package

More information

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Installing the Cisco ONS FAP-4 Fuse Alarm Panel Installing the Cisco ONS 15454-FAP-4 Fuse Alarm Panel Product Number: 15454-FAP-4= This document explains how to install, test, operate, and maintain the Cisco ONS 15454-FAP-4 fuse alarm panel. This document

More information

All-In-One Wireless Security System V1.0. Model #: MG-6060

All-In-One Wireless Security System V1.0. Model #: MG-6060 All-In-One Wireless Security System V1.0 Model #: MG-6060 Reference and Installation Manual DRAFT Table of Contents Introduction... 5 About Magellan and this Manual... 5 Conventions... 5 Specifications...

More information

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0 IRIS Touch Quick Installation & Maintenance Guide Version 1.0 Page 2 of 16 IRIS Touch Quick Installation & Maintenance Guide Version 1.0 Contents 1. Introduction... 4 2. Product Features... 4 3. Package

More information

Sentient. Downloader Manual D4854

Sentient. Downloader Manual D4854 Sentient Downloader Manual D4854 Dycon Ltd Tel: +44 (0)1443 471 060 Fax: +44 (0)1443 479 374 Cwm Cynon Business Park Mountain Ash CF45 4ER - UK www.dyconsecurity.com sales@dyconsecurity.com TABLE OF CONTENTS

More information