1 Technical data sheet MONICO-.. Turnkey automation station MONICO-.. Forms an efficient fire protection system together with the motorisation sets BF(G)24MP Completely wired controller in matching control cabinet For control and monitoring of fire dampers via MP-Bus As stand-alone or master/slave configuration Technical data Safety notes Electrical data Power supply voltage AC 230 V ±15%, 50/60 Hz Internal supply voltage of controller 24 VAC Connection Terminal strips, max. 250 VAC Cable diameter mm 2 Bus connection MP-Bus 2-wire, conductor length up to mm 2 Connection of up to 8 Top Line fire protection actuators Inputs/outputs Digital inputs Connection of floating contacts from the fire alarm and ventilation system. Supply from controller, 6 ma Digital outputs 2 relay outputs for fan release and transmission of the fault report. Switching capacity 250 VAC, 2A Safety Protection class II totally insulated Degree of protection IP65 EMC CE according to 89/336/EEC Mode of operation Type 1 (acc. to EN ) Ambient temperature range C Non-operating temperature range C Ambient humidity range % RH, non-condensating (EN ) Maintenance Maintenance-free Dimensions/weight Dimensions 420 x 314 x 143 mm (H x W x D) Weight approx. 4.8 kg! The MONICO system solution is not allowed to be used outside the specified field of application, especially in aircraft or in any other airborne means of transport. Please note: 230 V power supply voltage! Only components explicitly approved for this purpose by Belimo are allowed to be used for the MONICO system solution. The network may only be configured, and the system configuration changed, by suitably trained and authorised personnel! Check the relevant standards and national directives prior to planning the system. Consult a fire protection expert if necessary. 1

2 MONICO-.. Automation station for fire dampers System configuration Controller in MONICO-.. automation station Electrical installation Motorisation sets BF(G)24MP External operating panel Z-PKT0FSW210 Mechanical installation Control cabinet installation Master station connection (MONICO-1M) The controller is installed in the automation station and completely wired. After the fire dampers have been connected via the MP-Bus, the digital inputs/outputs and possibly further slave stations have been connected and the supply voltage has been applied, the MONICO-.. fire protection system is ready for parameterisation and commissioning. The motorisation sets (BF24MP and BFG24MP) consist of a communications-capable fire protection actuator of the Top Line series with an integrated thermoelectrical tripping device and a communication and power supply unit for connection to the MP-Bus network. These motorisation sets are only provided to fire damper manufacturers! The optionally available operating panel Z-PKT0FSW210 allows the MONICO-.. fire protection system to be decentrally controlled and operated. The operating panel is connected to the plan bus of the controller. The control cabinet is fastened directly to the wall with 4 screws (for dimensions / drill hole distances, see page 24). Protective caps must be attached (guarantees protection class II). Observe enclosed installation instructions! TC1 QF1 FU3 / 4 Master and slave station designations TC1 Transformer 230/24 V, 30 VA QF1 Automatic circuit breaker, primary FU3 / 4 Fuse, secondary XP1 Terminal strip for mains connection XA Terminal strip for bus connection and digital inputs/outputs TCONN plan connection strip GND Ground connection rail XP1 XA TC1 TCONN GND QF1 FU3 / 4 Slave station connection (MONICO-1S) XP1 XA TCONN GND 2

3 Automation station for fire dampers MONICO-.. Electrical installation Wiring diagram Master AC 230 V Slave station connection Wiring diagram Slave XP1 PE L N TCONN plan XA C4 NO4 C5 NO5 IDC1 ID1 IDC1 ID2 MP GND Fan release Relay outputs AC 230 V XP1 PE L N Fault TCONN Fire alarm system plan Digital inputs Ventilation system MONICO-1M Master station connection MONICO-1S XA MP GND 2-wire MP-Bus (BF(G)24MP set) 2-wire MP-Bus (BF(G)24MP set) plan connection TCONN plan connection strip J14 J The jumpers J14 and J15 must be attached at position 1 and 2. Connections Terminal screw connection Telephone plug pin Function 0 Grounding for shielded cable GND 3 3 Rx / Tx 4 4 Rx+ / Tx+ 5 5 GND 6 3

4 MONICO-.. Automation station for fire dampers Electrical installation plan connection MONICO-.. MONICO-.. MONICO-.. Connection of fire damper to MP-Bus MP GND AC 230 V Master Slave Slave MP 2 x 2 wires twisted (0.5 mm 2 ) shielded BUS TECHNOLOGY BY BELIMO MP GND 24 V Ya 24 V LED max. 200 m Optional smoke detector contact (floating) PC Tool BKN230-24MP BF(G)24MP set M BF(G)24TL-T-ST User interface Operation of the system Operating panel on master station No. / key Function 1 LCD infos 2 and reset faults 3 Prg Open navigation menus 4 Esc To overview / back 5 Scroll down 6 Scroll up 7 Confirm entry Master station operating panel The master station has an operating panel, consisting of an LCD display and a keyboard with 6 keys Prg Esc Key combinations on master Key combinations for external operating panel Software information display + (> 3 s) Software information display / (> 10 s) Call up addressing functions + + Connect supply voltage Set display contrast + Prg + / Call up addressing functions / (> 5 s) Slave addressing Jump between master / slave + + Connect supply voltage (controller) * Prg + Esc * Address of the operating panel must be 0! 4

5 Automation station for fire dampers MONICO-.. Menu structure Keys Menu tree Esc Prg Faults (password) Language selection Network configuration Fan release Actuator section Addressing Scenario management Configuration of fire alarm and ventilation input Configuration of reports plan management Reset to basic setting Manual system test Automatic system test Test of local actuator Adaptation Maintenance (password) Manual system test Automatic system test Test of local actuator Addressing Adaptation switch-off list Actuator info M01 M07 Main menu History Clock Inputs/ Outputs Stored faults Test results Faults of entire system Test results of entire system Set date / time Set day of the week System status Status display Reset buffer Interface / modem / printer configuration Text designation for system Info System info Network Actuator status Last test result plan status switch-off delay Actuator info 5

6 MONICO-.. Automation station for fire dampers Commissioning System configuration checklist Systems with slave Software parameter factory settings See table on page 21 Application software Addressing Procedure 1) Check electrical connection of system and switch on entire system 2) Select language 3) Address stations and external operating panel (if present), see below 4) Reset all stations to basic setting 5) Set the number of stations connected to the network on the master 6) Release necessary digital inputs on the master (for fire alarm system, input of ventilation system) 7) Set time of day For systems with slave(s), an external operating panel (Z-PKT0FSW210) is required for commissioning! 8) If desired, set parameters for automatic system test 9) If GSM modem is present, set SMS configuration 10) Set number of connected actuators at all stations 11) Address digital actuators 12) Set desired scenario at each station 13) Set groups and system status to On 14) Trigger system test to test entire system Same software for master and slave The stations are supplied with preinstalled application software. The same software is installed in the master and the slave. System division and network addresses Master and slave are addressed from 1 to max. 12 or 32 for one operating panel. RS plan Group 1 Group 2 Group 3 Master Slave Slave BF24MP set or BFG24MP set BF24MP set or BFG24MP set BF24MP set or BFG24MP set MP1 MP1 MP1 MP BUS TECHNOLOGY BY BELIMO MP2 230 VAC MP BUS TECHNOLOGY BY BELIMO MP2 230 VAC MP BUS TECHNOLOGY BY BELIMO MP2 230 VAC MP3 MP3 MP3 to MP8 to MP8 to MP8 6

7 Automation station for fire dampers MONICO-.. Commissioning Addressing of the controllers Addressing of the master: Keep UP and ALARM key pressed Switch on power supply of the master The following display will appear after a few seconds: PLAN ADDRESS: 1 UP: INCREASE DOWN: DECREASE ENTER: SAVE & EXIT The master always has address 1! (This is the factory setting!) The desired address can be set with the UP and DOWN key and saved with the ENTER key. Addressing of external operating panel: Address 32 is already set for the external operating panel upon delivery (default value)! Keep all 3 arrow keys pressed for at least 5 s address setting :32 I/O Board address:02 P:01 Adr Priv/Shared Trm1 32 Sh Trm2 None -- Trm3 None -- Ok?YES Address of the external operating panel Shows the address of the controller to which the operating panel is connected Should always be set to Sh (Shared) Confirm any changes by entering YES See also the separate documentation (data sheet) of the external operating panel. Addressing of slave (factory setting: address 2): Connect external operating panel to slave Keep all 3 arrow keys pressed for at least 5 s address setting : 0 Set address of external operating panel to 0! The following display appears: ADDRESS Changed Switch off power supply of slave Keep UP and ALARM key on the external operating panel pressed Switch power supply on again The following display will appear after a few seconds: PLAN ADDRESS: 2 UP: INCREASE DOWN: DECREASE ENTER: SAVE & EXIT Set address for the slave The desired address can be set with the UP and DOWN key and saved with the ENTER key. Important: After the slaves have been addressed, set the address of the external operating panel back to 32! 7

8 MONICO-.. Automation station for fire dampers Main menu Main menu The main menu is accessed by pressing the Esc key several times. Esc Group: 00/00 M01 Function: SLAVE Main menu Group status : OFF System status: OFF Group: 00/00 M02 Local configuration Actuators num.: Group: 00/00 M03 Actuators status: C C C C C C C C Group: 00/00 M04 Safety function act N N N N N N N N Shows in which group you are / how many groups are present in total. Shows function of the respective station (master / slave). Switches the individual groups on and off. Factory setting: ON Switches the overall system on and off. Factory setting: OFF Enter number of connected digital and standard actuators. Enter number of digital actuators (BF-Top). Factory setting: 0 of the actuator positions. 1 8: digital actuators. C = closed, O = open Safety function display (triggered by BAE, smoke detector, excess temperature of actuator). Has safety function been triggered? N = no, Y = yes Group: 00/00 M05 Dig. act. fault: N N N N N N N N Group: 00/00 M06 Last test result: N N N N N N N N Group: 00/00 M07 Fault reset: N N N N N N N N for fault in actuator. (overload, MP-Bus, etc.) Is a fault present? N = no, Y = yes of the last test result. Was a fault determined during the last test run? N = no, Y = yes Allows a pending fault message to be reset. Remark: If the fault is still present, it cannot be reset. Reset fault? N = no, Y = yes 8

9 Automation station for fire dampers MONICO-.. Main menu Group: 00/00 M08 Status display of the digital outputs. Password entry Fan status : OFF Fault status: OFF Group reset: M09 01:0 02:0 03:0 04:0 05:0 06:0 07:0 08:0 09:0 10:0 11:0 12:0 Group on/off: M12 01:0 02:0 03:0 04:0 05:0 06:0 07:0 08:0 09:0 10:0 11:0 12:0 Digital output contact for fan release: Status Digital output contact for collective fault: Status Status display of the stations connected to the network. Non-connected stations are not displayed. 0 = inactive, not present, 1 = active Slave on = 1 Slave off = 0 The installation menu is protected by a password. Menu Password: 0000 Enter passwords using the scroll keys. Language selection Language: C01 Select menu language. DEUTSCH Select menu language. Language selection Network configuration Network config. Fan release Contr. config. C02 Num. of controllers (pcoxs) present in the plan: 00 Enter number of controllers connected to the network. Factory setting: 00 Fan release C03 Delay of actions on startup: 30 s Enter fan startup delay. Factory setting: 30 s 9

10 MONICO-.. Automation station for fire dampers Actuator selection MPBUS Act. conf. C04 Actuators num.: 0 Enter number of connected actuators. Actuator selection Addressing The actuators can only be addressed if Group config. in display C05 is set to Yes. After the actuators have been addressed, Group config. must be set to OFF again! The digital actuators can be addressed in two ways: manually (MAN, with hand crank) automatically (AUTO, with serial number of the actuator). Manual addressing MPBUS Act. conf. C05 Group config: No Current act.: Configuration group: Yes = addressing of the actuators possible, No = standard operation of the system No / Yes Actuator that is currently being queried Manual addressing Actuator 1/ C06 Address. type: MAN Set address : No of the current actuator (act. 1 = MP1). Select method: manual (MAN) / automatic (AUTO). Start manual addressing (select Yes ) *. Automatic addressing * Note After Yes has been selected, the hand crank of the respective actuator must be operated within 5 minutes. The corresponding actuator then sends its serial number to the controller and is programmed with the corresponding MP address (here MP1). After the addressing has taken place, the display changes from Yes to No. Actuator 1/ C06 Address. type: AUTO Set address : No Select automatic addressing. Automatic addressing Actuator 1/ C07 Serial number: Set address: No Assigns the address (in this case MP1) to the actuator. Enter the serial number of the respective actuator (with scroll and ENTER keys). Yes = Save address in actuator. 10

11 Automation station for fire dampers MONICO-.. Scenario management 3 predefined scenarios are available: 1) 1:1: Only the fire damper whose sensor (temperature, smoke) is triggered will close. 2) All: As soon as a sensor (temperature or smoke) in the network is triggered, all fire dampers in the entire network will close. 3) 2: Dependence between each two fire dampers (MP1-MP2, MP3-MP4, MP5-MP6, MP7-MP8). Scenario management Scenario Manag. C22 Enable scenario ALL in the plan: No Scenario Manag. C23 Enable scenario 2 on the plan: No C24 Configure local or remote controller? LOCAL Activate scenario All? Factory setting: No Yes = Scenario 2 is selected for this station. Selects the controller in which the scenario is to be set. Local = master, distributed = slaves C25 Read scenario s conf of controller: 02 Read status: STOP Actuator 1 C26 Scenario : CUSTOM Group dep.: 02 Actuat.dep: 08 Reads out the scenario settings of the slaves from the master. Read in a scenario from a slave. Reading status The scenario CUSTOM is activated for actuator 1. A customer-specific scenario could be set here. Actuator 1 is dependent on actuator 8 in group 2. Save the current C36 scenario configurat. in the controller:00 Write status: STOP Scenario Manag. C37 All actuators are configurated with scenario ALL! Saves a set scenario in the corresponding slave. Enter controller address. STOP / START indicating that the scenario ALL has been activated for all actuators. Scenario ALL is active. 11

12 MONICO-.. Automation station for fire dampers Configuration of the inputs of the fire alarm and ventilation system Config. of fire alarm and ventilation input Master Control. C49 Enable F&S alarm from D.I.: Yes Master Control. C50 Enable D.I. from ventilation sys: No Configuration of the actuator messages plan management Actuator 1/ C51 Enable indication of Safety message : Yes Gen. fault msg.: Yes Is a fire alarm system connected to the master? Yes / No. Factory setting: Yes Close fire dampers when the ventilation system is switched off? (Protection of tangible assets when ventilation system is switched off) No / Yes. Factory setting: No You can define for each actuator whether the respective messages and faults are to be output. These settings may only be changed after consultation with the person responsible for safety! Message config. Transmit safety message? Factory setting: Yes Transmit fault message? Factory setting: Yes plan management plan Management C61 Enable fault detect offline loc.: Yes offline plan: Yes The plan messages can be switched off if necessary. Local message display: Yes / No. Factory setting: Yes plan message display: Yes / No. Factory setting: Yes 12

13 Automation station for fire dampers MONICO-.. Reset to basic setting Reset to basic setting Manual system test Automatic system test plan Management C62 Delay fault detect. offline loc.: 000s offline plan: 000s Reset values to default: Manual test Start test: No C64 No C65 A fault is displayed when the network is interrupted. The delay time Disconnection until fault display can be set here. Local delay time in s. Factory setting: 30 s plan delay time in s. Factory setting: 30 s Reset parameters of the respective station to their basic setting? No / Yes. Factory setting: See Appendix A test run of the entire network can be manually triggered here. All actuators move into the safety position (Closed) and then open again. Manual system test Trigger test run? No / Yes Automatic system test C66 Enable automatic self-test: No Interval: EVERY 24h Self-test config C67 The system can be set here so that it automatically carries out a periodic self-test of the entire network. The period type and the time can also be set. Every 24 hours / monthly / weekly / every 48 hours Setting of start day and time. Start on : Monday Time : 00 : 00 Enter start day. Enter time. 13

14 MONICO-.. Automation station for fire dampers Saves the test result in the history file. Delay before C68 save the result of self-test: 300s Set delay time in s. Factory setting: 300 s Automatic system test Test of local actuator Test of local actuator Adaptation Local act. test: C69 A1:0 A2:0 A3:0 A4:0 A5:0 A6:0 A7:0 A8:0 Adaptation C70 A1:0 A2:0 A3:0 A4:0 A5:0 A6:0 A7:0 A8:0 Possibility of testing a single actuator within the network. 0 = Standard operation 1 = Start test run When the test run has been successfully completed, the display automatically returns to 0. Adaptation of a new actuator to the fire damper. 0 = Standard operation 1 = Start adaptation When the adaptation has been successfully completed, the display automatically returns to 0. Adaptation switch-off delay switch-off delay Actuator info Actuator info New password C71 LCD Backlight-off delay: 000s Actuator 1/ C72 ver.hw : ver.bios: The switch-off delay time of the display background lighting can be set. Switch-off delay in s. Factory setting: 120 s of hardware / software version. of hardware version. of BIOS and software version. of actuator serial number. INSTALL. Menu C80 Set new password using the scroll keys. Confirm with ENTER key. New password: 0000 Enter new password. 14

15 Automation station for fire dampers MONICO-.. Maintenance Password entry Manual system test Maintenance Manual system test Automatic system test Maintenance Menu Password: 0000 Manual test Start test: No A01 A02 Enable automatic self-test: No Interval: EVERY 24h Self-test config A03 Enter the password using the scroll keys. Confirm with ENTER key. Enter password. A test run of the entire network can be manually triggered here. All actuators move into the safety position (Closed) and then open again. Trigger test run? No / Yes The system can be set here so that it automatically carries out a periodic self-test of the entire network. The period type and the time can also be set. Maintenance Automatic system test Every 24 hours / monthly / weekly / every 48 hours Setting of start day and time. Start on : Monday Time : 00 : 00 Delay before A04 save the result of self-test: 000s Enter start day. Enter time. Saves the test result in the history file. Set delay time in s. Factory setting: 300 s Test of local actuator Maintenance Test of local actuator Local act. test: A05 A1:0 A2:0 A3:0 A4:0 A5:0 A6:0 A7:0 A8:0 Possibility of testing a single actuator within the network. 0 = Standard operation 1 = Start test run When the test run has been successfully completed, the display automatically returns to

16 MONICO-.. Automation station for fire dampers Maintenance Addressing The actuators can only be addressed if Group config. in display A06 is set to Yes. After the actuators have been addressed, Group config must be set to OFF again! The digital actuators can be addressed in two ways: manually (MAN, with hand crank) automatically (AUTO, with serial number of the actuator). Manual addressing Maintenance Manual addressing Automatic addressing MPBUS Act. conf. A06 Group config: No Current act.: Actuator 1/ A07 Address. type: MAN Set address : No of the current actuator (Act. 1 = MP1). Configure group: Yes / No. Select method: manual (MAN) / automatic (AUTO). Start manual addressing (select Yes ) *. * Note After Yes has been selected, the hand crank of the respective actuator must be operated within 5 minutes. The corresponding actuator then sends its serial number to the controller and is programmed with the corresponding MP address (here MP1). After the addressing has taken place, the display changes from Yes to No. Maintenance Actuator 1/ A07 Address. type: AUTO Set address : No Select automatic addressing. Automatic addressing Actuator 1/ A08 Serial number: Set address: No Assigns the address (in this case MP1) to the actuator. Enter the serial number of the respective actuator (with scroll and ENTER keys). Yes = Save address in actuator. Adaptation Maintenance Adaptation Adaptation A23 A1:0 A2:0 A3:0 A4:0 A5:0 A6:0 A7:0 A8:0 Adaptation of a new actuator to the fire damper. 0 = Standard operation 1 = Start adaptation When the adaptation has been successfully completed, the display automatically returns to 0. switch-off delay Maintenance switch-off delay A24 LCD Backlight-off delay: 120s The switch-off delay time of the display background lighting can be set. Switch-off delay in s. Factory setting: 120 s 16

17 Automation station for fire dampers MONICO-.. Maintenance Actuator info of software number / serial number of the actuator. Maintenance Actuator 1/ A25 Actuator info New password History Viewing local fault history ver.bios: MAINTENANCE Menu A33 New password: 0000 Fault history: H01 of BIOS and software version. of actuator serial number. Set new password using the scroll keys. Confirm with ENTER key. Enter new password. History N 00 00:00 00/00/00 Fault number Time / date Stored faults NO FAULTS! H02 Erase local faults history memory: No Fault in plain text. Delete fault history at this station. Delete? No / Yes. Viewing local test history History Test results Test history: H03 n 00 00:00 00/00/ N N N N N N N N H04 Erase local test history memory: No Fault number Time / date Fault determined during test run? No / Yes (N / Y). Delete test history at this station? No / Yes 17

18 MONICO-.. Automation station for fire dampers History Viewing fault history of entire system Stored Master H05 History Fault history: Last update status: wait... Faults of entire system Mast. al. hist.: H06 Group:00 N 00 00:00 00/00/00 NO FAULTS! Viewing test history of entire system History Stored Master Test history: Last update Status: wait... H07 Test results of entire system Mast.test grp:00 H08 00/00/00 00: N N N N N N N N Load histories of slaves into master. The slaves send their history data to the master. Select group and fault number. Time / date Fault in plain text. Load saved test results of the slaves into the master. The slaves send their history data to the master. Select group and fault number. Date / time Fault determined during test run? No / Yes (N / Y). Clock Setting date, time and day of week Today: K01 Shows set time and date. Clock Set date, time Clock 00:00 00/00/00 Change time: K02 00:00 00/00/00 Day of week: Time / date Set time and date. Set day of week. Set day of week 18

19 Automation station for fire dampers MONICO-.. Inputs/outputs Status display Inputs/ outputs Digital Input I01 Status display 1: C 4: C 2: C 5: C 3: C 6: C Digital Output 1: O 2: O 3: O 4: O 5: O BMS ID : 000 Speed I02 I03 : 1200 bps Protocol : Carel Shows the status of the digital inputs of the station. C = closed, O = open C = closed, O = open Shows the status of the digital outputs of the station. C = closed, O = open C = closed, O = open Shows ID number, transmission speed and transmission protocol ID number of the system Transmission speed Transmission protocol Shows inquiry to delete the internal buffer of the interface Erase message I04 queue? No Delete internal buffer of the interface: No / Yes Identification Site ID: 01 I09 Shows text designation for the system Name: Building A Text designation for system Groupe 01 I10 Shows text designation for the group Name: Ground Floor Text designation for group External modem: For installation and parameterisation, see separate modem documentation 19

20 MONICO-.. Automation station for fire dampers Info System info Info System info Network CAREL S.p.A. F01 Brugine (PD) Italia Cod.: FLBELMFS0A Ver.: /07/07 System info F02 Card type: pco1xs Bios: /02/07 Boot: /07/06 Information on the version of the installed application software. Belimo application code Version of the application software of the BIOS and boot version number. BIOS version number Boot version number Remark: The network menu is only displayed when at least one slave is connected to the master! Actuator status Network Actuator status Network status N01 Call group: 02 Selection of the group. Select group number. Group: 02/04 N02 Actuators status: C C C C C C C C Group: 02/04 N03 Safety funct. active N N N N N N N N Status display of the actuators (group 02). O = open / C = closed Status display of the safety function of the actuators. A = active / N = not active Last test result Network Last test result Group: 02/04 N04 Last test result: N N N N N N N N Group: 02/04 N05 Actuators fault: N N N N N N N N Status display of last test result: A = active / N = not active Fault with digital actuator MP7, group 02. Fault with digital actuator MP7, group 02. A = active / N = not active 20

21 Automation station for fire dampers MONICO-.. Software parameter factory settings Parameters Menu page Factory setting (Range) Group status M01 on System status M01 off Number of digital actuators M02 0 (0...8) Number of stations in plan C02 0 (1...15) Ventilation delay C03 30 s ( s) Number of standard actuators C04 0 (0...2) Delay of standard actuators during startup C04 80 s ( s) Scenario management C22, C23 no Input of fire alarm system C49 yes Input of ventilation system C50 no Safety-relevant messages of the actuators C51 C60 yes Fault messages of the actuators C51 C60 yes plan management C61 yes plan delay of fault display C62 30 s ( s) Save test results of the automatic test run: Delay C s ( s) LCD Backlight-off delay C s ( s) Status of the digital output contacts Status of the digital outputs Condition Selected scenario Fan release Contact Fault Contact System test (test of all dampers) 1, 2, or all OFF Open OFF Open Test of an individual damper 1, 2, or all ON Closed OFF Open plan interruption 1, 2, or all ON Closed ON Closed Sensor (channel, excess temperature, smoke detector) triggered 1 OFF Open ON Closed Sensor (channel, excess temperature, smoke detector) triggered 2 ON 1) Closed ON Closed Sensor (channel, excess temperature, smoke detector) triggered all OFF Open ON Closed Ventilation system off (dig. input open) 1, 2, or all ON Closed OFF Open Ventilation system on (dig. input closed) 1, 2, or all OFF 2) Open OFF Open Fire alarm system triggered (dig. input open) 1, 2, or all OFF Open OFF Open Fire alarm system in standard operation (dig. input closed) 1, 2, or all ON Closed OFF Open 1) Changes to OFF as soon as the last damper of the master controller has closed 2) Changes to ON as soon as the first damper of the master controller is open 21

22 MONICO-.. Automation station for fire dampers Troubleshooting Checking / maintenance Please consult the following table before calling the responsible maintenance service! System ok! System: Off Group: Off System alarms 01: 02: 03: 04: 05: 06: Meaning Solution System works perfectly, no further steps necessary. The overall system and the current group are switched off. Fault display Possible cause Solution Shows in which group a fault is present (example: group 2). = No fault = Fault Fault display Possible cause Solution Select system and group and switch them on. Update the faults stored in the History menu of the master (screen H5). Select group 2 in screen H6 and read out the detailed fault description. Carry out further steps according to the displayed fault. AL01 Fire&Smoke alarm from D.I. (master) External fire alarm system reports fire alarm and has closed all fire dampers. Check the status of the fire alarm system. Fault display Possible cause Solution Fault messages not available actuator 1 AL04 The bus connection or the supply voltage to the corresponding actuator is interrupted. Check the bus connection and the supply voltage at the actuator. 22

23 Automation station for fire dampers MONICO-.. Troubleshooting Fault display Possible cause Solution AL20 Fault: local unit off-line plan AL21 Fault: Group 02 off-line plan AL52 Warning: Actuator 1 closed in dependence The local controller can no longer communicate via the plan bus. Fault display Possible cause Solution The first slave (group 02) can no longer communicate via plan bus. Fault display Possible cause Solution Digital actuator 1 (MP1) has been closed in dependence on an other actuator. Fault display Possible cause Solution Check plan bus connection. Check plan connection. Scroll further using the scroll keys until the responsible fault is displayed, e.g. Channel temperature > 72 C digital actuator 2. This means that actuator 1 has been closed in dependence on actuator 2 (scenario 2 is active). Group: 00/00 M03 Actuators status: O O O O O * O O Actuator is not correctly addressed. The display * means that digital actuator 6 (MP6) has not been correctly addressed; the MP-Bus line or the power supply to the actuator is interrupted. 1) Check MP-Bus connection 2) Check power supply of the actuator 3) Address actuator 6 again 23

24 MONICO-.. Automation station for fire dampers Dimensions Dimensional diagram of MONICO-.. automation station Accessories External operating panel Z-PKT0FSW210 See separate documentation Telephone cable Z-S90CONN000 Z-PLW0PGSM00 GSM kit Z-PCO100MDM0 Cable with telephone plugs. Dual-band modem kit with antenna, connecting cable and power pack (see separate documentation). RS232 interface card for connecting GSM modem or serial protocol printer T3-MONICO en Subject to changes

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491 Bender Incorporated 700 Fox Chase, Coatesville PA 1930 Tel.: (800) 356-466 Fax: (610) 383-7100 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control function

More information

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491 Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 06401 807-0 Fax: 06401 807-59 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control

More information

Insulation fault evaluator EDS460-DG

Insulation fault evaluator EDS460-DG Insulation fault evaluator for localising insulation faults in DC IT systems with a number of branch circuits where high system leakage capacitances are involved Preliminary data sheet TDB108021en/09.2008

More information

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

Modular Standard HP Chiller 1/4 screw compressor with Carel driver Program for pco¹ pco 2 and pcoc Modular Standard HP Chiller 1/4 screw compressor with Carel driver Manual version 1.0 25 September 2003 Program code: FLSTDmMSDE Do we want you to save you time and money?

More information

REPEATER FS5200R INSTRUCTION MANUAL

REPEATER FS5200R INSTRUCTION MANUAL REPEATER FS5200R INSTRUCTION MANUAL Instruction Manual Page1 CONTENTS 1. Introduction... 3 2. Function... 3 3. Technical data... 3 4. Contents of delivery... 4 5. General information... 5 6. Duty Mode...

More information

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS.  A4741 / Rev.1 DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS User Manual and Menu Map A4741 / Rev.1 www.entes.com.tr ATTENTION -Disconnect all power before connecting the device. -Don t remove

More information

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Phone: 040 807-0 Fax: 040 807-259 Alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC display

More information

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems) ISOSCAN EDS460/490 EDS461/491 Insulation fault locators with control and display function for EDS systems (insulation fault location systems) EDS460-490_D00085_01_D_XXEN/01.2017 ISOSCAN EDS460/490 EDS461/491

More information

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power T M User Manual MarinaGuard Ground Fault Monitoring Panel For Marina Shore Power NAE1095810 / 03.2013 T M Bender Inc. USA: 700 Fox Chase Coatesville, PA 19320 Toll-Free: 800-356-4266 Phone: 610-383-9200

More information

Remote alarm indicator and test combination MK2430

Remote alarm indicator and test combination MK2430 Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Tel.: 040 807-0 Fax: 040 807-259 Remote alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC

More information

BLAUAIR AUTOMATIC CONTROL SYSTEM

BLAUAIR AUTOMATIC CONTROL SYSTEM BLAUAIR AUTOMATIC CONTROL SYSTEM S30 (KVENT, TH-TUNE) S31 (KVENT) S32 (KVENT, PGDE) EN USER S MANUAL CONTENTS Safety requirements... 3 Purpose... 4 Technical data... 5 Installation and set-up... 6 Control...

More information

REMOTE CONTROL FOR CHILLER MYCHILLER

REMOTE CONTROL FOR CHILLER MYCHILLER REMOTE CONTROL FOR CHILLER MYCHILLER GENERAL FEATURES... 3 MAIN FUNCTIONS AND EQUIPMENT:... 3 LCD DISPLAY... 4 KEYBOARD... 5 BOARD CONFIGURATION... 7 LIST OF MAIN PARAMETERS... 7 CONFIGURATION OF MAIN

More information

BURGLAR ALARM PANEL BS-468

BURGLAR ALARM PANEL BS-468 BURGLAR ALARM PANEL BS-468 Contents 1. Description... 3 2. Instructions for the user... 4 2.1Basic operations... 4 Complete system.... 4 Split system.... 4 2.2 Armed system indication... 5 2.3 Advanced

More information

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances _D00108_00_D_XXEN/05.2015 ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances

More information

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63 Fire Extinguishing Control Panel FS5200Е INSTRUCTION MANUAL Revision 8/01.17 Instruction Manual Page 1 1. 2. 3. 4. 4.1. 4.2. 4.2.1. 4.2.2. 4.2.3. 4.2.4. 4.2.5. 4.2.6. 4.2.7. 4.2.8. 4.2.9. 4.2.10. 4.2.11.

More information

GLOBAL. InstallatIon & operation manual

GLOBAL. InstallatIon & operation manual InstallatIon & operation manual INDEX 1. INTRODUCTION... 5 2. FEATURES AND FUNCTIONS 2.1 Reporting Options... 2.2 Interfaces... 2.3 Programming... 2.4 Indicators and Controls...... 6 6 6 6 6 3. INSTALLATION...

More information

Halton SAFE / 7.14 user guide and installation instructions

Halton SAFE / 7.14 user guide and installation instructions Halton SAFE / 7.14 user guide and installation instructions VERIFIED SOLUTIONS BY H A LTO N Enabling Wellbeing Table of contents 1 System description 3 2 User Accounts 4 3 Main menu 7 3.1 Main menu - Change

More information

Tri-Stack Smart System

Tri-Stack Smart System Tri-Stack Smart System TM Notes & Warnings - The protection provided by this equipment may be impaired if it is not used in the manner specified herein. - Ensure all wiring meets applicable national and

More information

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM 2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with,,,, 0 and signal inputs Storage of the last state of inputs and sequence in the case

More information

Operation manual. Rooftop Packaged Unit

Operation manual. Rooftop Packaged Unit Operation manual Rooftop Packaged Unit odels: UATYQ20ABAY1 UATYQ25ABAY1 UATYQ30ABAY1 UATYQ45ABAY1 UATYQ50ABAY1 UATYQ55ABAY1 UATYQ65ABAY1 UATYQ75ABAY1 UATYQ90ABAY1 UATYQ110ABAY1 UATYQ115ABAY1 UATYQ20AFC2Y1

More information

DAP III Zone Master User s Guide

DAP III Zone Master User s Guide DAP III Zone Master User s Guide Data Aire, Inc. 230 West BlueRidge Avenue Orange, California 92865 Document Number 600-000-788 March 2010 Revision 1.0 Document # 600-000-788 1 Overview The Data Aire DAP

More information

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 505 Grünberg Tel.: 060 807-0 Fax: 060 807-59 A-ISOMETER IRDH575 Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with

More information

User manual DATALogic2 technical specifications for precision conditioner unit with integrated humidifier

User manual DATALogic2 technical specifications for precision conditioner unit with integrated humidifier DATALogic2 DAT AIR CONTROLLER Manual 201716A02 Issue 09.00 Replaces --.-- User manual DATALogic2 technical specifications for precision conditioner unit with integrated humidifier 1370 Program code: FLAIRMCDZC

More information

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort USER MANUAL S203 Controller for three circuits - control for 2 heating circuits - 1 domestic hot water control Saving energy, creating comfort This user manual consists of two parts. Issues that are intended

More information

Memcom Emergency Telephone

Memcom Emergency Telephone Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

EW 40 Wireless Fan Control

EW 40 Wireless Fan Control Installation & Operating Manual EW 40 Wireless Fan Control USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Revision 6/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems Honeywell Life Safety Iberia C/Pau Vila 15-19; 08911 Badalona Barcelona T. 902 03 05 45; Internacional:+34932424236 www.honeywelllifesafety.es infohlsiberia@honeywell.com ibox Modbus Server Gateway for

More information

600 Range Dialer Installation Manual. Version 1.0

600 Range Dialer Installation Manual. Version 1.0 600 Range Dialer Installation Manual Version 1.0 The information contained is supplied without liability for any errors or omissions. No part may be reproduced or used except as authorised by contract

More information

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB Summary 1 CONNECTIONS... 3 1.1 TEMPERATURE PROBES...3 1.2 LOW VOLTAGE DIGITAL INPUTS...3 1.3 LIVE DIGITAL INPUTS...4 1.4 RELAY OUTPUTS...5 2 POWER SUPPLY... 6 3 SERIAL CONNECTIONS... 6 4 SOFTWARE... 7

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting Operation Manual GMA200-MW16 Gas detection controller for wall mounting GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, GERMANY TEL. +49 / (0)231 / 564 00 0 FAX +49 / (0)231 / 516 313

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly Operation Manual GMA200-MT Gas detection controller for mounting rail assembly GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)231 / 564 00 0 FAX +49 / (0)231

More information

RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE. Climate Cŏntrol Zoning System Installation Guide

RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE. Climate Cŏntrol Zoning System Installation Guide RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE Climate Cŏntrol Zoning System Installation Guide Uponor Climate Cŏntrol Zoning System Installation Guide Published by

More information

HRX Technical Manual. Version 1.2

HRX Technical Manual. Version 1.2 HRX 5000 Technical Manual Version 1.2 Contents: Specification...2 Connectors...5 RS-485 Network Connectors (J6 and J7)...5 RS-232 to Printer (J19)...6 RS-232 to PC (J8)...7 TCP/IP...8 Power (J21)...9 Fire

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

Fire control panel detect 3004 plus and accessories

Fire control panel detect 3004 plus and accessories Fire control panel detect 3004 and accessories The modular fire alarm panel detect 3004 is the basic version of a broad product portfolio of the system detect 3000. Up to 20 fire control panels can be

More information

THX-DL Data Logger USER & INSTALLATION MANUAL V

THX-DL Data Logger USER & INSTALLATION MANUAL V THX-DL Data Logger USER & INSTALLATION MANUAL V1.2012 www.thermomax-refrigeration.com Contents PRESENTATION Summary of Features 2 INSTALLATION Safety Precautions 4 THX Unit 4 Sensors 4 Alarm Relay 4 Power

More information

NurseCall Main Unit F.01U V User Manual

NurseCall Main Unit F.01U V User Manual NurseCall Main Unit F.01U.252.699 V1.1 2012.01 en User Manual NurseCall Main Unit Table of Contents en 3 Table of Contents 1 Safety instructions 6 1.1 Importance of safety instructions 6 1.2 Disregarding

More information

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options

More information

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL. Page 1 / 15 Installation and user manual Page 2 / 15 Sira s.r.l. reserves the right to make modifications to this manual and the product described herein without prior notice. Sira s.r.l. shall not be

More information

Standard Chiller Modular HP 1/4 Generic/Bitzer screw compressor and CAREL valve

Standard Chiller Modular HP 1/4 Generic/Bitzer screw compressor and CAREL valve Application program for pco¹ pco² pco 3 Standard Chiller Modular HP 1/4 Generic/Bitzer screw compressor and CAREL valve 1.1 09 / 11 / 2006 version of manual Program code: FLSTDmMSBE We wish to save you

More information

FCD-wire Contents. List of Figures

FCD-wire Contents. List of Figures FCD-wire Contents FCD-X21 Configuration 1 Introduction... 1 2 Opening the FCD Application... 1 3 FCD Window... 2 4 FCD LEDs... 3 5 Configuration Operations... 4 FCD Info...4 FCD System Info...5 FCD Interface

More information

TE809-Ats Instructions Manual

TE809-Ats Instructions Manual TE809-Ats Instructions Manual Project: v2.0 PREFACE Thanking you for preference, TECNOELETTRA SRL hopes that the use of this equipment could be a reason of satisfaction. This manual is designed to put

More information

ModBus DE-1 INSTALLATION AND USER MANUAL

ModBus DE-1 INSTALLATION AND USER MANUAL ModBus DE-1 INSTALLATION AND USER MANUAL INTESIS Software, SL Distributed by DURAN ELECTRONICA S.L Tomás Bretón 50 28045 MADRID, España duran@duranelectronica.com www.duranelectronica.com 2 2010 DURAN

More information

SACE PR021/K SIGNALLING UNIT

SACE PR021/K SIGNALLING UNIT SACE PR021/K SIGNALLING UNIT 1SDH000559R0002 L3016 1/52 EN CONTENTS 1. GENERAL INFORMATION...4 1.1. FOREWORD...4 1.2. APPLICABLE SCENARIOS...5 2. TECHNICAL SPECIFICATIONS...6 2.1. ELECTRICAL CHARACTERISTICS...6

More information

Operating Manual RCM420

Operating Manual RCM420 Operating Manual RCM420 Residual current monitor for AC current monitoring in TN and TT systems Software version: D240 V1.2x TGH1410en/03.2012 Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Germany

More information

RS 0021 DIGITAL GAS DETECTION CONTROL UNIT FOR SENSORS WITH S-BUS PROTOCOL. USER MANUAL Read carefully before use

RS 0021 DIGITAL GAS DETECTION CONTROL UNIT FOR SENSORS WITH S-BUS PROTOCOL. USER MANUAL Read carefully before use RS 0021 DIGITAL GAS DETECTION CONTROL UNIT FOR SENSORS WITH S-BUS PROTOCOL USER MANUAL Read carefully before use GENERAL INFORMATION This device is a gas control unit with RS485 serial communication, based

More information

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert) Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert) P.N. 7876C (export) February 12, 2015 For Spas equipped with BP2100, BP6013 controllers and Spa Touch panel. Spa

More information

Fire damper actuators. Selection and integration.

Fire damper actuators. Selection and integration. Fire damper actuators. Selection and integration. Motorised fire dampers are shut-off devices that prevent fire and smoke from spreading through ventilation systems. In the event of a fire, they protect

More information

CARD ACCESS CONTROL SYSTEM

CARD ACCESS CONTROL SYSTEM SECTION 13851 CARD ACCESS CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: A complete, operable, tested, integrated proximity access control system, to operate on a proximity principle where

More information

DC 60 & DM 60 displays

DC 60 & DM 60 displays USER MANUAL DC 60 & DM 60 displays BALTIC FLEXAIR ENERGY AIRCOOLAIR COMPACTAIR FLATAIR (& Inverter) AQUALEAN DC60-DM60-IOM-1310-E www.lennoxemea.com Summaries 1 Display DC60 1.1 Introduction... 2 1.2

More information

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0 IRIS Touch Quick Installation & Maintenance Guide Version 1.0 Page 2 of 16 IRIS Touch Quick Installation & Maintenance Guide Version 1.0 Contents 1. Introduction... 4 2. Product Features... 4 3. Package

More information

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software INSTALLATION AND COMMISSIONING GUIDE CAN bus-based I/O module, CIO 208 8 relays Mounting Terminals and wiring Commissioning, using the utility software DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45

More information

Product Data Sheet. Remote Terminals. Features:

Product Data Sheet. Remote Terminals. Features: Remote Terminals Product Data Sheet Features: Based around two core products, the Mx- 4010 Remote Display Terminal (RDT) and the fully functional Mx-4020 Remote Control Terminal (RCT). Both remote terminals

More information

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert) Spa Touch Control Panel with 2000, 2100 controllers (Spa Owner s Manual insert) P.N. 7876B February 11, 2015 For Spas equipped with BP2000, BP2100 controllers and Spa Touch panel. Spa Touch Control Panel

More information

BURGLAR ALARM PANEL BS-468/A

BURGLAR ALARM PANEL BS-468/A BURGLAR ALARM PANEL BS-468/A Contents 1. Description... 4 2. User instructions... 5 2.1. Basic operations... 5 Complete System... 5 Split System... 5 2.2. Armed system indication... 6 2.3. Advanced operations...

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with 8, 16, 24, 32, 40 and 48 signal inputs Status retention of inputs and sequence in case

More information

Added password for IP setup page : Password must be in IP format!

Added password for IP setup page : Password must be in IP format! NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP

More information

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training PowerWizard Level 1.0 & Level 2.0 Control Systems Training New Systems Current Systems Systems Comparison Level 1 Level 2 Level 3 Level 4 PowerWizard Level 3.0 PowerWizard Level 4.0 Overview Common parts

More information

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001 SLATE Base Module R8001A1001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform can

More information

KSUF CONTROL AND MONITORING UNIT. Description. Installation Designed for wall installation.

KSUF CONTROL AND MONITORING UNIT. Description. Installation Designed for wall installation. KSUF can then be grouped into a maximum of four fire zones. One output for fan control. CONTROL AND MONITORING UNIT Valid from week of manufacture 06/2014 Description The KSUF is a control and monitoring

More information

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections. ISSUES ISSUE DATE RELEASED DETAILS OF CHANGE AUTHOR 4 Rev 2 September 2004 Changes for 4000 series. DB 4 Rev 3 April 2005 Screen shots updated and other minor changes K.Z. 4 Rev 4 September 2006 4 Rev

More information

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16 TraceTek TTSIM-1A TraceTek Sensor Interface Module with Relay Installation/OPERATION Instructions Approvals and Certifications TYPE NM General Signaling Equipment 76LJ Only AC versions are UL listed and

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS GENERAL INFORMATION Please read these instructions and keep them in a safe place. These instructions must

More information

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products Document 475595 Microprocessor Controller for Tempered Air Products Reference Guide for the Microprocessor Controller Please read and save these instructions. Read carefully before attempting to operate

More information

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number Innovation In and Out of Parlour Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual Version - 1.0 Date - June 2016 Part Number - 39-0038 Index Manual Version... 3 About the Remote Vacuum

More information

I/O logger box. User manual NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT!

I/O logger box. User manual NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT! I/O logger box User manual NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT! H i g h E f f i c i e n c y S o l u t i o n s WARNING DISPOSAL CAREL bases the development of its products on decades

More information

Fire Control Panel FS5100

Fire Control Panel FS5100 Fire Control Panel FS5100 INSTRUCTION MANUAL Revision 6/02.11 Contents 1. Introduction... 5 2. Terminology... 5 3. Function... 7 4. Technical data... 7 4.1. Modules... 7 4.1.1. Type of modules... 7 4.1.2.

More information

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB Summary 1 CONNECTIONS... 8 1.1 TEMPERATURE PROBES...8 1.2 PRESSURE PROBES...9 1.3 LOW VOLTAGE DIGITAL INPUTS...10 1.4 LIVE DIGITAL INPUTS...11 1.5 RELAY OUTPUTS...12 2 VOLTAGE/FREQUENCY INPUT...13 3 POWER

More information

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: / Planungsbüro + Service: Esteraustr. 10, 56379 Holzappel Tel.: 0 64 39 / 90 19 90 Fax.: 0 64 39 / 90 19 91 E-Mail: u.ramakers@umsitec.de Entwicklung + Fertigung + Service: Heerweg 15 D, 73770 Denkendorf

More information

Diagnostics and Monitoring System WEB Tool 2. User Manual

Diagnostics and Monitoring System WEB Tool 2. User Manual Diagnostics and Monitoring System 2 (Translation of the original documentation) User Manual S/N: Valid from: 01.05.2012 Rev.: 2.0 2 Rev. 1.... 1 1.1 General information... 1 1.1.1 Equipment... 1 1.1.2

More information

User manual. KNXgal. version

User manual. KNXgal. version User manual version 1.3 gal Management alarm control panels Galaxy from bus powered from bus Communication indication on and with Galaxy control panel DIN rail mount (1 modul) Adjustable address on with

More information

User Guide

User Guide ABS control panel CP 112 212 ON ON ON ON ON ON User Guide www.absgroup.com ii ABS CONTROL PANEL CP 112 212, USER GUIDE Copyright 2008 ABS Group. All rights reserved. This manual, as well as the software

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

Entero Voice Alarm system.

Entero Voice Alarm system. Entero Voice Alarm system. Entero ESC installation menu guide Rev. 1.0 The manufacturer reserves specification privileges. Information in this manual is subject to change without prior notice or obligation.

More information

EasyTronic III MANUAL SERVICE

EasyTronic III MANUAL SERVICE rev.6 EasyTronic III MANUAL SERVICE General characteristics: Power supply 24 Vac ±15% Max consumption at 24Vac 300mA Relay outputs 6 Maximum relay current 8 A res. Serial standard RS232 2 Serial standard

More information

Section 9 System Operation

Section 9 System Operation Section 9 System Operation Operation of the control panel is simple. Menus guide you step-by-step through operations. This section of the manual is an overview of the operation menus. Please read this

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS XXXXXXX-0 EN 1904 READ AND SAVE THESE INSTRUCTIONS BASIC-PLC CONTROLLER MANUAL For all Condair desiccant dryer with equipped with Basic- PLC valid from version: PLC-35/PLC-45 18.04.03 Dehumidification

More information

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App Heating is great when you control it. USER MANUAL Wireless Programmable Room Thermostat Model No.: LS99111010 Scan for App Contents 1. Overview... 01 2. System Installation... 02 2.1 Install and Wiring

More information

N M AirControl AHU. Control manual

N M AirControl AHU. Control manual N 10.63 M 03-2016 AirControl AHU Control manual EN CONTENTS PAGE 1 - MONITORING AND CONTROL 2 1.1 The program 2 1.2 The HMI terminal 2 1.3 The controller 4 1.4 Description of the air handling units 4

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE MANUAL Prg Sel line alarm on on/off alarm enter Clear EMIpro MICROPROCESSOR CONTENTS 1 GENERAL CHARACTERISTICS Page 2 1.1 General description Page 2 2 EMIPRO USER INTERFACE Page

More information

Gas Detection System TOX ALARM DG2000-Garage

Gas Detection System TOX ALARM DG2000-Garage Gas Detection System TOX ALARM DG2000-Garage Gas Detection System 32 independent programmable channels 2 programmable alarm levels for each gas = up to 6 for each channel LCD alphanumeric display of gas

More information

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock. Preface Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock. The GSM Security Alarm ( The Alarm ) adopts the most advanced

More information

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440) Safety Temperature Limiter STL 50 Certified to DIN EN 14597 (replaces DIN 3440) Features M For use as: STB Protection - temperature limiter ASTB Exhaust gas - protection - temperature limiter STW Protection

More information

Laptop / PC Programming Manual

Laptop / PC Programming Manual Laptop / PC Programming Manual Doc. # Fire PC Program rev B 01.07 This Document is property of Evax Systems, Inc. The Evax Fire Solutions Programmer Components 2 1.0 System Setup 4 1.1 Interface Setup

More information

5, SE GÅNGHESTER,

5, SE GÅNGHESTER, KSUB Control and monitoring unit Valid from week of manufacture 48/2005 Description The KSUB is a control and monitoring unit designed to control various types of fire/smoke dampers and fans in a flexible

More information

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) IRDH375_D00124_01_D_XXEN/07.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product

More information

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET CommStat 6 Controller for Redundant HVAC Systems PRODUCT DATA SHEET General Description The CommStat 6 HVAC controller is designed for controlling up to six redundant air conditioners in an E-House or

More information

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options Table 4 External Maintenance Switch Configuration Options External Maintenance Switch Options Installed with Interlock Option Option Auxiliary Contact Status open = On Test position or Maintenance position,

More information

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL Advanced Gen-set Controller OPERATOR S MANUAL Display readings Push-button functions Alarm handling Log list Document no.: 4189340607A SW version 3.5X.X or later Table of contents 1. ABOUT THIS DOCUMENT...3

More information

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option SM3000 Videographic Recorder User Guide (RTU) Communications Option ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow

More information

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 505 Grünberg Tel.: 00 807-0 Fax: 00 807-259 Insulation monitoring device for unearthed AC/DC systems (IT systems for the supply of operating theatre

More information

LCF Touch Modbus Datasheet Application Security Advice Caution

LCF Touch Modbus Datasheet Application Security Advice Caution LCF Touch Modbus Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet Subject to technical alteration Issue date: 3.11.214 Application Modern design flush mounting fan coil room

More information