Liquid Adhesive Detection System Alarm Box

Size: px
Start display at page:

Download "Liquid Adhesive Detection System Alarm Box"

Transcription

1 Liquid Adhesive Detection System Alarm Box Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA

2 Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence to Nordson Corporation Attn: Customer Service Lakefield Drive Duluth, GA Notice This is a Nordson Corporation publication which is protected by copyright. Original copyright date No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Nordson Corporation. The information contained in this publication is subject to change without notice. Trademarks AquaGuard, Blue Box, Control Coat, Equi=Bead, Excel 2000, FloMelt, FoamMelt, FoamMix, Helix, Hot Shot, Hot Stitch, Meltex, MicroSet, MultiScan, Nordson, the Nordson logo, OmniScan, Porous Coat, Posi-Stop, RBX, Sure-Bond, UniScan, UpTime, and Versa-Spray are registered trademarks of of Nordson Corporation. BetterBook SM, CF, Controlled Fiberization, Easy-Screen, Fibermelt, Flo-Tracker, PrintGuard, Package of Values, and Swirl Coat are trademarks of Nordson Corporation Nordson Corporation

3 Table of Contents i Table of Contents 1. Safety Safe Operation Safety Symbols Qualified Personnel Intended Use Installation and Electrical Connections Operation Less-obvious Dangers Action in the Event of System Malfunction Maintenance/Repair Cleaning Liquid Adhesives Description Specifications Dimensions Installation Unpacking Mounting Connecting Electrical Service Connecting the Alarm Box to the Liquid Adhesive Detection System Wiring the Alarm Box Outputs Setting the A/B Toggle Switch Nordson Corporation

4 ii Table of Contents 4. Operation Turning the Alarm Box On Turning the Alarm Box Off Faults Understanding Momentary Faults Understanding Continuous Faults Troubleshooting Repair Replacing Fuses Terminal Block Fuse Replacement Power Supply Fuse Replacement Parts Using the Illustrated Parts List WM 500 and WM 408/500 Alarm Box Recommended Spare Parts Wiring Diagrams Standard Alarm Box Special Alarm Box Nordson Corporation

5 Liquid Adhesive Detection System Alarm Box 1 Liquid Adhesive Detection System Alarm Box WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. 1. Safety Safety instructions contained in this section and throughout this document apply to tasks that may be performed with the liquid adhesive application system components and the liquid adhesive used. It is very important that these safety instructions are always followed. Failure to do so could result in personal injury, death and/or damage to the system or other equipment. Safe Operation With this in mind, here are some basic safety recommendations: Read and become familiar with the Safety section prior to installing, operating maintaining or repairing the system. Read and follow the warnings which appear within the text and are related to specific tasks. Store this document within easy reach of personnel operating or maintaining the system. Wear personal protective equipment such as safety goggles, gloves or respiratory equipment where this is required by peculiarities of the system and/or the material. Familiarize yourself with and follow all safety instructions prescribed by your company, general accident prevention regulations and government safety regulations Nordson Corporation

6 2 Liquid Adhesive Detection System Alarm Box Safety Symbols The following symbols are used to warn against dangers or possible sources of danger. Become familiar with them! Failure to heed a warning could lead to personal injury, death and/or damage to the system or other equipment. WARNING: Failure to observe may result in personal injury, death, or equipment damage. WARNING: Risk of electrical shock. Failure to observe may result in personal injury, death, or equipment damage. WARNING: Disconnect equipment from the line voltage. WARNING: Danger! High pressure. Wear safety goggles when working on a liquid adhesive application system. WARNING: Risk of explosion or fire. Fire, open flames and smoking prohibited. WARNING: System and material pressurized. Release pressure. Failure to observe may result in serious injury. CAUTION: Failure to observe may result in equipment damage Nordson Corporation

7 Liquid Adhesive Detection System Alarm Box 3 Qualified Personnel Qualified personnel is defined here as individuals who thoroughly understand the equipment and its safe operation, maintenance and repair. Qualified personnel are physically capable of performing the required tasks, familiar with all relevant safety rules and regulations and have been trained to safely install, operate, maintain and/or repair the equipment. It is the responsibility of the company operating the equipment to see that its personnel meet these requirements. Intended Use The system is designed and intended to be used only for the purpose described in the Description section. Uses not in accordance with that section or as described in this document are considered unintended uses and not in accordance with governing regulations. WARNING: Use of this equipment in ways other than described in this document may result in personal injury, death, or equipment damage. The following actions of the owner or operator of the system are some, but not all, examples of unintended use which would permit Nordson to claim it is not responsible for personal injury or property damage arising from such unintended use: Unapproved modifications or changes to the system Failure to comply with the safety instructions Failure to comply with the instructions concerning installation, use, operation, maintenance or repair, or when these tasks are carried out by unqualified personnel Use of inappropriate or incompatible foreign materials or auxiliary equipment Failure to observe workplace safety rules or regulations issued by government authorities or safety councils Nordson Corporation

8 4 Liquid Adhesive Detection System Alarm Box Installation and Electrical Connections Prior to installation, check intended location and surrounding area for any potential hazards during operation. All electrical, pneumatic, gas and hydraulic connections and installation of all system components may only be carried out by qualified personnel. Observe installation instructions for components and accessories. Equipment must be properly grounded and fused according to the rated current consumption (see ID plate). Cables which run outside the system must regularly be checked for wear or damage. Power supply wire gauge and insulation must be sufficient to handle rated current consumption. Cables must never be squeezed or pinched. Do not locate cables or hoses in high traffic areas. Check liquid adhesive feed hoses, screwed connections and compressed air lines regularly for leaks. These are to be replaced at the first signs of cracks, brittleness etc. Release system pressure completely beforehand. WARNING: Failure to install the system properly, and especially failure to ensure electrical, pressurized and high pressure feed connections are made correctly may result in serious injury or death Nordson Corporation

9 Liquid Adhesive Detection System Alarm Box 5 Operation The system should only be operated when it is in working order. It should only by operated by qualified persons following all regulations valid for liquid adhesive systems. Never allow the system to be operated by personnel under the influence of substances which reduce their reaction times, or who are not able to operate the equipment for physical reasons. Prior to each startup of the system, check protection and warning devices and make sure they are fully functional. Do not operate the equipment if these devices are not functioning properly. When the removal of safety equipment is required for installation, maintenance or repair, it must be reconnected immediately upon completion of the work. In a humid environment, only equipment featuring a corresponding class of protection may be operated. Do not operate the system in an explosive environment. Keep parts of the body and clothing away from rotating parts. Do not wear loose articles of clothing when operating or servicing equipment with rotating parts. Remove wrist watches, rings, necklaces or similar jewelry and pin up or cover long hair before performing any work on or with the equipment. The wearing of protective gloves may prove hazardous in certain circumstances where rotating parts are present and may therefore be forbidden. To carry out measurements on the substrate or system components, switch off parent machine and/or system and wait until the equipment comes to a standstill. Never point guns or applicator nozzles at yourself or other persons Nordson Corporation

10 6 Liquid Adhesive Detection System Alarm Box Less-obvious Dangers WARNING: An operator or service technician working with the equipment should be aware of the less-obvious dangers that often cannot be completely minimized at production sites: Pressurized system components The possibility that electrical potentials may remain in the system after the system was de-energized Liquid adhesive vapors Hydraulically or pneumatically operated system components Uncovered winding parts Action in the Event of System Malfunction If the system malfunctions, switch it off immediately. Turn the main switch off, or use emergency stop switch or similar safety feature as provided. After equipment has come to a standstill and before reoperating it, have it repaired by qualified personnel. Maintenance/Repair Allow only qualified personnel to perform the procedures described in this document. Work should only be carried out on a completely depressurized system, following all safety procedures. NOTE: Depending on the configuration of the liquid adhesive application system, high pressure may remain between application head(s) and pressure regulator or pump/s even after the system has been switched off using the main switch or the emergency stop. This especially applies to multi-hose configurations between pump/s and application head/s. Prior to maintenance and repair work it is therefore essential to ensure that all liquid adhesive application system components are depressurized as follows: 1. Release input pressure in front of pump by shutting off customer compressed air supply Nordson Corporation

11 Liquid Adhesive Detection System Alarm Box 7 2. Release any remaining system pressure behind the pumps by manually operating the application heads. Secure pneumatically-and hydraulically-operated equipment against uncontrolled movement. Switch off system electrically. WARNING: Some voltage is still present in the control cabinet even after equipment has been turned off at the main switch. Complete the following steps prior to maintenance or repair: 1. Disconnect external power supply. 2. Lock out external power supply. 3. Check no voltage is present. 4. Ground and short. 5. Cover nearby live sections. If liquid adhesive application system is left idle for extended periods (e.g. overnight or long breaks) Nordson recommends applying Vaseline to the application head nozzles to prevent them from drying out and becoming blocked as a result. Only use genuine Nordson parts Nordson Corporation

12 8 Liquid Adhesive Detection System Alarm Box Cleaning NOTE: Always refer to the liquid adhesive manufacturer s Material Safety Data Sheet or material information sheet before working with any cleaning fluids. WARNING: Never clean any aluminium part or flush any system using halogenated hydrocarbon fluids. Examples of common halogenated hydrocarbons are: dichloromethylene, 1,1,1-trichloroethylene and perchlorethylene. Halogenated hydrocarbons may react violently with aluminium parts. Never use an open flame to clean the system or its components. Check that (warm) water can be used to clean the liquid adhesive system components, possibly with the addition of household washing-up liquid. If this is not possible, use only the cleaning fluid stated in the liquid adhesive manufacturer s information. If the manufacturer recommends heating the cleaner, note the flash point. Ensure sufficient room ventilation to draw off vapors. WARNING: Fire, open flames and smoking are prohibited when cleaning fluids are used. Observe all explosion prevention regulations. Cleaning fluids may only be heated using temperature controlled and explosion-protected heaters. Disposal must be according to the waste key in the DIN Safety Data Sheet. Liquid adhesives or residue, solvent or separating agents must not be released into open waterways. In the case of a leak or spillage, contain liquid and if necessary use an absorbant material e.g. sawdust to soak it up; then proceed according to the relevant waste disposal regulations. If the liquid adhesive application system is to be idle for an extended period, the entire system should be flushed and outlets sealed with Vaseline. Warm water is usually used to flush application systems with which water based liquid adhesives are processed. If the liquid adhesive manufacturer specially recommends a flushing agent, the manufacturer s safety and disposal details must be followed Nordson Corporation

13 Liquid Adhesive Detection System Alarm Box 9 Liquid Adhesives As there is a wide variety of liquid adhesives available with different compositions and characteristics, it is impossible here to give an exhaustive list of safety notes reflecting the typical characteristics of liquid adhesives. The use of liquid adhesives in Nordson s liquid adhesive application systems therefore requires reference to the liquid adhesive manufacturer s documents beforehand. Information relating to safety aspects e.g. concerning solvent content, hazards and countermeasures in the event of liquid adhesive coming into contact with skin or mucous membranes are contained in the technical data sheets and the DIN Safety Data Sheets from the manufacturer. NOTE: Always refer to the manufacturer s Material Safety Data Sheet or material information before working with any liquid adhesives. It may be necessary to refer to the manufacturer s notes on the use of materials from a third party. These may be required for processing a liquid adhesive, but hazards arising from their use are not necessarily mentioned by the manufacturer of the liquid adhesive. Liquid adhesives may still give off vapors when they are processed correctly. The smell produced can cause some annoyance. This is especially true where liquid adhesives are used that contain solvent, thus requiring the use of breathing equipment e.g. a filter. If the prescribed processing conditions are not followed, harmful decomposition products may develop. Therefore, the vapors must be removed. Wash hands well before breaks and when work is finished. If liquid adhesive comes into contact with eyes or mucous membranes, rinse well with water - especially the eyes. Change damp clothes, and seek medical advice if it is swallowed. Disposal must be according to the waste key in the DIN Safety Data Sheet. Liquid adhesives or residue, solvent or separating agents must not be released into open waterways. In the case of a leak or spillage, contain liquid and if necessary use an absorbant material e.g. sawdust to soak it up; then proceed according to the relevant waste disposal regulations. If solvents or separating agents are used to process a liquid adhesive, follow the safety and disposal information from the manufacturer Nordson Corporation

14 10 Liquid Adhesive Detection System Alarm Box 2. Description This alarm box, which can be used with WM 500 (standalone) and WM 408/500 (combination) liquid adhesive detection systems, uses a horn and light to indicate a defective product. The alarm box: Produces a visible and audible indication that a defective product has been detected by the liquid adhesive detection system Provides a convenient trigger that can be used to shut down the parent machine in the event of a continuous fault condition Provides a 24 Vdc power output for a carton ejector, kicker, or ink marking unit (for WM 408/500 combination systems only) The alarm box will operate on Vac. Refer to Specifications for more information. Table 1 shows how the alarm box responds differently to faults on WM 500 units and the WM 408/500 systems. Contacts Momentary fault Continuous fault Table 1 Alarm Box Fault Responses WM 408/500 Units (contacts normally open) With a Fault, the Contacts Close Horn Light Alarm Box Response Close Horn Light PMI contacts change state Cast-out 1 Close 24 Vdc available at terminal block XT-2, positions 1 and 8 WM 500 Units (contacts normally closed) With a Fault, the Contacts Open Horn Light Alarm Box Response Open Horn Light PMI contacts change state Open Not Used 1999 Nordson Corporation

15 Liquid Adhesive Detection System Alarm Box 11 Specifications Refer to the following chart for product specifications. Item Incoming power Ambient operating temperature Outputs Inputs Vac Hz 0 C 50 C Specification Maximum load for Cast-out 1, 24 Vdc output is 25 W (1 Amp) Parent Machine Interlock contact rating 5 Amp 240 Vac and 5 Amp 28 Vdc WM 500 Systems Two sets of normally closed contacts: Momentary fault Continuous fault WM 408/500 Systems Three sets of normally open contacts: Momentary fault Continuous fault Cast-out 1 Dimensions See Figure 1 for the dimensions of the alarm box mm (10.93 in.) mm (13.50 in.) mm (12.75 in.) mm (14.75 in.) mm (5.10 in.) mm (8.00 in.) A Fig. 1 Alarm Box Dimensions 1999 Nordson Corporation

16 12 Liquid Adhesive Detection System Alarm Box 3. Installation This section contains guidelines and procedures for installing the alarm box. Unpacking Exercise normal care to prevent equipment damage during unpacking. After unpacking the equipment, inspect it for any damage that may have occurred during shipping. Look for dents and scratches and make sure all fasteners are tight. Report any damage to your Nordson representative. Mounting Use the following guidelines when mounting the alarm box. Choose a convenient location. Isolate the alarm box from vibration. Provide adequate room for routing wires and cables Mount the alarm box by inserting 1 / 4 -in. bolts through the four holes (two on the top and two on the bottom) on the alarm box. Connecting Electrical Service Use this procedure to connect electrical service to the alarm box. WARNING: Risk of electrical shock. Failure to observe may result in personal injury, death, or equipment damage. 1. Disconnect and lock out electrical power to the input power supply. 2. Loosen the screws on the latches that secure the alarm box door and then lift the lip of the latches over the edge of the door. 3. See Figure 2. Open the alarm box door and locate the strain relief (4) on the lower left corner of the alarm box. 4. Route the incoming line voltage (line 1 and line 2) and ground wire through the strain relief (4) into the alarm box. 5. Connect line 1 to the L1 connector (2). 6. Connect line 2 to the L2 connector (3). 7. Connect the ground wire to the ground connector (1) Nordson Corporation

17 Liquid Adhesive Detection System Alarm Box Fig. 2 Electrical Connections 1. Ground connector 2. L1 connector 4 3. L2 connector 4. Strain relief A Connecting the Alarm Box to the Liquid Adhesive Detection System Use this procedure to connect the alarm box to the liquid adhesive detection system. 1. See Figure 3. Locate the alarm cable (1) extending from the bottom of the alarm box A Fig. 3 Alarm Cable of Alarm Box 1. Alarm cable 1999 Nordson Corporation

18 14 Liquid Adhesive Detection System Alarm Box Connecting the Alarm Box to the Liquid Adhesive Detection System (contd.) 2. See Figure 4. Plug the other end of the alarm cable into the alarm output (1) on the back of the liquid adhesive detection system. 1 Fig. 4 Alarm Cable Output of Liquid Adhesive Detection System 1. Alarm output A Wiring the Alarm Box Outputs Use this procedure to wire the alarm box outputs. 1. Locate terminal block XT-2 on the lower right side of the din rail inside the alarm box. 2. See Figure 5 and use it as a reference for wiring and securing the outputs. 3. Route the wires through the strain relief at the lower right side of the alarm box Nordson Corporation

19 Liquid Adhesive Detection System Alarm Box G G XT 2 CAST OUT 1 + OUTPUT 24Vdc NORMALLY OPEN MACHINE INTERLOCK CONTACTS NORMALLY CLOSED MACHINE INTERLOCK CONTACTS CAST OUT 1 OUTPUT SAME AC VOLTAGE L2 AS L1 AND L2 (ONLY ON PART ) L A Fig. 5 Wiring Alarm Box Outputs Setting the A/B Toggle Switch The toggle switch allows the alarm box to work with normally open alarm contacts (WM 408/500) or with normally closed alarm contacts (WM 500). Set the toggle switch to the appropriate position. Set the switch to position A if you are connecting the alarm box to a WM 408/500 combination system. Set the switch to position B if you are connecting the alarm box to a WM 500 standalone system. Installation is complete. Close the alarm box door and secure the latches Nordson Corporation

20 16 Liquid Adhesive Detection System Alarm Box 4. Operation This section contains operating instructions for the alarm box. Turning the Alarm Box On Follow this procedure to use your alarm box. 1. Turn on the liquid adhesive detection system. Refer to your system manual for the startup procedure. 2. Place the alarm box power switch in the on position and verify that the green power indicator is on. The alarm box is now activated and will alert you when the liquid adhesive detection system detects a defective product. Turning the Alarm Box Off To turn off the alarm box, place the power switch in the off position and verify that the green power indicator is off. 5. Faults The alarm box receives two types of faults from the liquid adhesive detection system: momentary and continuous. Understanding Momentary Faults Momentary faults occur when the condition that causes the fault requires no operator intervention to clear the fault. During a momentary fault, the alarm horn and light will operate for 3 seconds. When the system detects a momentary fault on a: WM 500 standalone system, the alarm box input contacts open for 3 seconds. WM 408/500 combination system, the alarm box input contacts close for 3 seconds Nordson Corporation

21 Liquid Adhesive Detection System Alarm Box 17 Understanding Continuous Faults Continuous faults occur when the condition that causes the fault requires operator intervention to clear the fault. During a continuous fault, the alarm horn and light will operate continuously until the fault is cleared at the liquid adhesive system s control panel. When the system detects a continuous fault on a: WM 500 standalone system, the alarm box input contacts open continuously and will not close without operator intervention. WM 408/500 combination system, the alarm box input contacts close continuously and will not open without operator intervention. 6. Troubleshooting If you experience problems with your alarm box, first check for any loose or disconnected wiring. If this does not resolve the problem, then refer to the troubleshooting table, which lists the possible problems and refers you to tests and corrective actions for handling those problems. When necessary, the table refers to more detailed repair procedures. Refer to your liquid adhesive detection system manual for further troubleshooting procedures. WARNING: Risk of electrical shock. Failure to observe electrical safety procedures may result in personal injury or death. Allow only qualified personnel to perform these maintenance procedures. Observe all high-voltage indicators. WARNING: Risk of equipment damage, personal injury, or death. Disconnect and lock out electrical power to the unit, including input/output (I/O) lines. WARNING: Electrostatic discharge can damage electrical components or result in personal injury or death. Be sure you are properly grounded before beginning any electrical troubleshooting procedure that involves working inside the electrical enclosure Nordson Corporation

22 18 Liquid Adhesive Detection System Alarm Box 6. Troubleshooting (contd.) Problem Possible Cause Corrective Action 1. The alarm box does not respond to any input signals from the detection system. 2. There is no 24 Vdc power. Continued on next page Alarm box not turned on No power to alarm box Liquid adhesive detection system not in run mode Alarm box not connected to detection system (on WM 408/500 adhesive detection systems only) No 24 Vdc power Fuse(s) F1 and F2 blown No AC power to 24 Vdc power supply Test: Check the position of the power switch. Corrective Action: Place the alarm box power switch in the on position. Test: Check for Vac between terminals L1 and L2. Corrective Action: Connect Vac power to terminals L1 and L2. Place the system in the run mode. Refer to the system manual. Test: Check the electrical connection between the liquid adhesive system and the alarm box. Corrective Action: Refer to Connecting the Alarm Box to the Liquid Adhesive Detection System in Installation. Test: Check for 24 Vdc between the positive (+) and negative ( ) terminals on XT-1. Corrective Action: Refer to No 24 Vdc power problem. Test: Check the fuses in terminals L1 and L2 on terminal block XT-1. Corrective Action: Replace blown fuse. Refer to Replacing Fuses in Repair. Test: Check the position of the power switch. Corrective Action: Place the alarm box power switch in the on position Nordson Corporation

23 Liquid Adhesive Detection System Alarm Box 19 Problem 2. There is no 24 Vdc power. (contd.) Possible Cause No AC power to 24 Vdc power supply Fuse on 24 Vdc power supply blown Corrective Action Test: Check for Vac between terminals L1 and L2. Corrective Action: Connect Vac power to terminals L1 and L2. Test: Check the fuses in the XT-1 L1 and L2 terminals. Corrective Action: Replace blown fuse. Refer to Replacing Fuses in Repair. Test: Check the fuse on the power supply. Corrective Action: Replace blown fuse. Refer to Replacing Fuses in Repair. 24 Vdc power supply bad Test: 1. Verify that the position of the alarm box power switch is on. 2. Verify that there is Vac between the L1 and L2 terminals. 3. Verify that the fuses in the XT-1 L1 and L2 terminals are operating. 4. Verify that the fuse on the power supply is good. Corrective Action: Replace the power supply. 3. The alarm box does not respond to a momentary fault signal, but it responds normally to continuous fault and cast-out 1 signals. Relay KA1 loose in socket Relay KA1 defective Test: Push relay KA1 firmly into its socket and retest. Test: Unplug relays KA1 and KA2 and switch their positions. If the horn and light now work for a momentary fault but not for a continuous fault, relay KA1 is defective. Corrective Action: Replace relay KA1. Refer to Replacing Relays in Repair. Continued on next page 1999 Nordson Corporation

24 20 Liquid Adhesive Detection System Alarm Box 6. Troubleshooting (contd.) Problem Possible Cause Corrective Action 4. The alarm box does not respond to a continuous fault signal, but it responds normally to momentary fault and cast-out 1 signals. 5. For WM 408/500 units only: there is no 24 Vdc power available at XT-2 positions 1 and 8 in response to a cast-out 1 signal, but the alarm box responds normally to momentary fault and continuous fault signals. 6. The horn and light operate continuously. Relay KA2 loose in socket Relay KA2 defective Relay KA3 loose in socket Relay KA3 defective A/B toggle switch in wrong position Test: Push relay KA2 firmly into its socket and retest. Test: Unplug relays KA1 and KA2 and switch their positions. If the horn and light now work for a continuous fault but not for a momentary fault, relay KA2 is defective. Corrective Action: Replace relay KA2. Refer to Replacing Relays in Repair. Test: Push relay KA3 firmly into its socket and retest. Test: Unplug relays KA1 and KA3 and switch their positions. If the horn and light no longer work for a momentary fault, but cast-out 1 now works, relay KA3 is defective. Corrective Action: Replace relay KA3. Refer to Replacing Relays in Repair. Change the position of A/B toggle switch and check for normal operation: Position A is for WM 408/500 combination systems. Position B is for WM 500 standalone systems only Nordson Corporation

25 Liquid Adhesive Detection System Alarm Box Repair Troubleshooting contains diagnostic procedures that may identify failed components. This section contains procedures for replacing alarm box components. Refer to Parts to order replacement components. Replacing Fuses There are three fuses in the alarm box-two in the XT-1 terminal block and one on the power supply. Use these procedures to replace a fuse. WARNING: Risk of electrical shock. Failure to observe electrical safety procedures may result in personal injury or death. Allow only qualified personnel to perform these procedures. Observe all high-voltage indicators. WARNING: Risk of equipment damage, personal injury, or death. Disconnect and lock out electrical power to the unit, including input/output (I/O) lines. WARNING: Electrostatic discharge can damage electrical components or result in personal injury or death. Be sure you are properly grounded before beginning any electrical troubleshooting procedure that involves working inside the electrical enclosure. 1. Place the alarm box power switch to the off position. 2. Loosen the screws on the latches that secure the alarm box door and then lift the lip of the latches over the edge of the door. 3. Open the alarm box door and locate the blown fuse Nordson Corporation

26 22 Liquid Adhesive Detection System Alarm Box Terminal Block Fuse Replacement 1. See Figure 6. Lift the tabs marked L1 and L2 to access the F1 and F2 fuses. 2. Remove the blown fuse and insert a new fuse of the same type. Refer to Recommended Spare Parts in Parts for part numbers. 3. Snap the tabs back into place on the terminal block. 4. Close the alarm box door and secure the latches. Fig. 6 Accessing Fuses F1 and F A Power Supply Fuse Replacement 1. Remove the blown fuse from the power supply and insert a new fuse of the same type. Refer to Recommended Spare Parts in Parts for fuse part numbers. 2. Close the alarm box door and secure the latches Nordson Corporation

27 Liquid Adhesive Detection System Alarm Box Parts To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use this five-column parts list, and the accompanying illustration, to describe and locate parts correctly. Using the Illustrated Parts List Numbers in the Item column correspond to numbers that identify parts in illustrations following each parts list. The code NS (not shown) indicates that a listed part is not illustrated. A dash ( ) is used when the part number applies to all parts in the illustration. The six-digit number in the Part column is the Nordson Corporation part number. A series of dashes in this column ( ) means the part cannot be ordered separately. The Description column gives the part name, as well as its dimensions and other characteristics when appropriate. Indentions show the relationships between assemblies, subassemblies, and parts. Item Part Description Quantity Note Assembly Subassembly 2 A Part 1 If you order the assembly, items 1 and 2 will be included. If you order item 1, item 2 will be included. If you order item 2, you will receive item 2 only. The number in the Quantity column is the quantity required per unit, assembly, or subassembly. The code AR (As Required) is used if the part number is a bulk item ordered in quantities or if the quantity per assembly depends on the product version or model. Letters in the Note column refer to notes at the end of each parts list. Notes contain important information about usage and ordering. Special attention should be given to notes Nordson Corporation

28 24 Liquid Adhesive Detection System Alarm Box WM 500 and WM 408/500 Alarm Box See Figure 7. Item Part Description Quantity Note Alarm box, WM 500 and WM 408/500, special Alarm box, WM 500 and WM 408/500, standard Nut, hex, machine, # Washer, lock, E, external, # Enclosure, electrical, alarm box Wire mount, cable strap, 4-way Power supply, AC input, 24 Vdc output Strap, cable, 0.06 in. x 1.75 in Wire group, alarm box, special 1 A Wire group, alarm box, standard 1 B Nut, hex, machine, #10-32, brass Linear switch, DPST, 250 V, 16 A, panel-mount Lamp, indicator, 24 Vdc, panel-mount, green Spacer, terminal block Terminal block accessory, jumper, 4-pole, 6.5 mm Terminal block accessory, rail, din, 35 mm x 7.5 mm Panel, electrical enclosure, alarm box Connector, strain relief, PG Tape, PE, electrical, 2.03 in Alarm cable for LAD with 7-pin plug Socket, Omron, DPDT, din, touch-proof Relay, Omron, 24 Vdc, DPDT Jumper bar assembly, T-block, 2-pole Switch, toggle, 2-position, SPDT Bracket, switch, alarm box Screw, socket, 8-32 x 0.50 in Washer, lock, external, #10 4 Continued on next page 1999 Nordson Corporation

29 Liquid Adhesive Detection System Alarm Box 25 Item Part Description Quantity O-ring, Viton, in. inside diameter x in. wide 3 Note Ring, retaining, external, 12, push-on Fuse, 4.00, fast-acting, 250 Vac, 5 mm x 20 mm 2 A Fuse, 2.00, fast-acting, 250 Vac, 5 mm x 20 mm 2 B Block, terminal, feed-thru 15 C Block, terminal, feed-thru Holder, fuse, 5 x 20, 250 Vac, 6.3 A Horn, with light, 24 Vdc 1 NS Terminal block accessory, din, end cap, fuse holder 1 NS Plate, information 1 NS Rivet, pop, 1 / 8 in. x in. 2 NS Screw, pan, x in 2 NS Washer, flat, in x 0.5 in. x 0.49 in. 2 NS Nut, hex, machine, # NS Marker, tag, terminal block 2 NS Terminal block accessory, marker, plus symbols 1 NS Terminal block accessory, marker, minus symbols 1 NS Terminal block accessory, marker, L1, L2, L3, N, GND 4 NS Name plate, Nordson, oval 1 NS Threaded spacer, 6-32 thread, round, 0.50 in. long, 0.25 in. outside diameter 4 NS Screw, socket, 6-32 x in. 8 NS Washer, lock, E, external, #6 8 NOTE A: Used in alarm box part number B: Used in alarm box part number C: The quantity for this item for the alarm box part number is 17. NS: Not Shown 1999 Nordson Corporation

30 26 Liquid Adhesive Detection System Alarm Box WM 500 and WM 408/500 Alarm Box (contd.) J L1 L1 L2 L2 + + KA1 KA2 KA A Fig. 7 WM 500 and WM 408/500 Alarm Box 1999 Nordson Corporation

31 Liquid Adhesive Detection System Alarm Box 27 Recommended Spare Parts Use the following parts list to stock and order spare parts and service items. Part Description Note Fuse, 4.00 A, fast-acting, 250 Vac, 5 mm x 20 mm A Fuse, 2.00 A, fast-acting, 250 Vac, 5 mm x 20 mm B, C Relay, Omron, 24 Vdc, DPDT NOTE A: Used in alarm box part number B: Used in alarm box part number C: Used in the 24 Vdc power supply Nordson Corporation

32 28 Liquid Adhesive Detection System Alarm Box 9. Wiring Diagrams This section contains the wiring diagrams for the standard alarm box (part ) and the special alarm box (part ). Standard Alarm Box See Figure 8. QS PIN #1 G1 J1 24VDC POWER SUPPLY + J2 PIN #3 PIN #1 PIN #4 PANEL DOOR KA1 KA2 KA3 XT SCHEMATIC BOTTOM VIEW OF RELAYS KA1, KA2 AND KA3 BROWN GREEN PINK GRAY YELLOW WHITE MOMENTARY FAULT INPUT CONTINUOUS FAULT INPUT CAST OUT 1 INPUT 2 1 PILOT + LIGHT HL 2 2A 1A SCHEMATIC BOTTOM VIEW OF SWITCH QS SA STAMPED SIDE A ALARM CABLE (RED WIRE) HA (BLACK WIRE) STAMPED SIDE B SCHEMATIC BOTTOM VIEW OF SWITCH SA HL A Fig. 8 Wiring Diagram for Standard Alarm Box 1999 Nordson Corporation

33 Liquid Adhesive Detection System Alarm Box 29 Special Alarm Box See Figure A QS 2 2A PIN #1 G1 J1 PIN #3 24VDC POWER SUPPLY + J2 5 6 PIN #1 PIN #4 PANEL XT XT 2 DOOR SCHEMATIC BOTTOM VIEW OF RELAYS KA1, KA2 AND KA3 2 1 PILOT LIGHT 2A 1A HL 2 SCHEMATIC BOTTOM VIEW OF SWITCH QS SCHEMATIC BOTTOM VIEW OF SWITCH SA + (RED WIRE) HA HL (BLACK WIRE) SA BROWN GREEN PINK GRAY YELLOW WHITE STAMPED SIDE A STAMPED SIDE B MOMENTARY FAULT INPUT CONTINUOUS FAULT INPUT CAST OUT 1 INPUT ALARM CABLE A Fig. 9 Wiring Diagram for Special Alarm Box 1999 Nordson Corporation

34 30 Liquid Adhesive Detection System Alarm Box 1999 Nordson Corporation

Automatic Hot Melt Melter/Feeder Retrofit Kit Mechanical Float Model. Part104506A

Automatic Hot Melt Melter/Feeder Retrofit Kit Mechanical Float Model. Part104506A Automatic Hot Melt Melter/Feeder Retrofit Kit Mechanical Float Model Part456A NORDSON CORPORATION. AMHERST, OHIO USA Corporation welcomes requests for information, comments and inquiries about its products.

More information

Remote Temperature Controller

Remote Temperature Controller Remote Temperature Controller Technical Manual Part 07 97A NORDSON CORPORATION. AMHERST, OHIO. USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address

More information

FC-2200 Flame Detector

FC-2200 Flame Detector FC-2200 Flame Detector Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence

More information

Non-RTD Hot Melt Hose Replacement

Non-RTD Hot Melt Hose Replacement Instruction Sheet P/N 7C 0 Safety WARNING: System pressurized! Relieve system hydraulic pressure before breaking any hydraulic connection or seal. Failure to relieve the system hydraulic pressure can result

More information

4-GALLON MOBILE PARTS WASHER

4-GALLON MOBILE PARTS WASHER Please read and save these instructions. Read through this owner s manual carefully before using product. Protect yourself and others by observing all safety information, warnings, and cautions. Failure

More information

20-GALLON MOBILE PARTS WASHER OWNER S MANUAL

20-GALLON MOBILE PARTS WASHER OWNER S MANUAL 20-GALLON MOBILE PARTS WASHER OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in

More information

Page 1 of 18. Part# /5/2013

Page 1 of 18. Part# /5/2013 Part# 1002655-06 8/5/2013 This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep for future reference INSTRUCTIONS

More information

Replacing a Gun Thermostat

Replacing a Gun Thermostat Instruction Sheet Replacing a Gun Thermostat WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation.

More information

3-1/2 GALLON PARTS WASHER OPERATING INSTRUCTION AND PARTS MANUAL. Model # 4KTV9

3-1/2 GALLON PARTS WASHER OPERATING INSTRUCTION AND PARTS MANUAL. Model # 4KTV9 3-1/2 GALLON PARTS WASHER OPERATING INSTRUCTION AND PARTS MANUAL Model # 4KTV9 QUALITY GUARANTEE: Should a Westward product fail to perform satisfactorily due to defect or poor workmanship within one

More information

Models: GW/R-T GW/R-2-T GW/R-3-T

Models: GW/R-T GW/R-2-T GW/R-3-T Part# GW/R-T-OM 1/12/04 TN Models: GW/R-T GW/R-2-T GW/R-3-T This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly

More information

Auto-Flo RT Gun. Customer Product Manual Part A--02. Issued 10/08 NORDSON CORPORATION AMHERST, OHIO USA

Auto-Flo RT Gun. Customer Product Manual Part A--02. Issued 10/08 NORDSON CORPORATION AMHERST, OHIO USA Customer Product Manual Issued 10/08 NORDON CORPORATION AMHERT, OHIO UA afety... 1 Qualified Personnel... 1 Intended Use... 1 Regulations and Approvals... 1 Personal afety... 1 High-Pressure Fluids...

More information

Heliport Perimeter Light Type MIJ

Heliport Perimeter Light Type MIJ Heliport Perimeter Light Document No. 96A0194 Issued: June 19, 1997 Rev. D: February 8, 2005 Manufactured to FAA Specification AC150/5390-2B and AC 150/5345-46B Copyright 2005 by Siemens Airfield Solutions,

More information

3.5-GALLON PARTS WASHER OWNER S MANUAL

3.5-GALLON PARTS WASHER OWNER S MANUAL 3.5-GALLON PARTS WASHER OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious

More information

PARTS WASHER Model: CW2D Part No:

PARTS WASHER Model: CW2D Part No: PARTS WASHER Model: CW2D Part No: 7630910 OPERATING & MAINTENANCE INSTRUCTIONS GC01/12 INTRODUCTION Thank you for purchasing this CLARKE Parts Washer. Before using the product, be sure to read these instructions

More information

20-GALLON PARTS WASHER OWNER S MANUAL

20-GALLON PARTS WASHER OWNER S MANUAL 20-GALLON PARTS WASHER OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious

More information

HDLV 55-Gallon Powder Drum Unloader

HDLV 55-Gallon Powder Drum Unloader Instruction Sheet P/N 07333 0 HDLV -Gallon Powder Drum Unloader Description See Figure. The HDLV -gallon powder drum unloader uses a Prodigy HDLV High Capacity pump to supply virgin powder to a powder

More information

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax Part# 1000692 7/12/99 tn INSTRUCTIONS This manual contains important information concerning the installation and operation of the gun washers listed at the right. Read manual thoroughly and keep for future

More information

55-Gallon Dispenser Package

55-Gallon Dispenser Package INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 308 666 Rev. A Husky 715 55-Gallon Dispenser Package 100 psi (6.9 bar) Maximum

More information

Fiber Optic Module. Part B NORDSON CORPORATION AMHERST, OHIO USA

Fiber Optic Module. Part B NORDSON CORPORATION AMHERST, OHIO USA Fiber Optic Module Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence to Nordson Corporation

More information

3.5 GALLON PARTS WASHER

3.5 GALLON PARTS WASHER 3.5 GALLON PARTS WASHER Assembly and Operating Instructions 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 1997 by Harbor Freight Tools. All rights

More information

918 Clock Gauge Installation, Operation, and Maintenance Instructions

918 Clock Gauge Installation, Operation, and Maintenance Instructions 98 Clock Gauge Installation, Operation, and Maintenance Instructions The 98 Clock Gauge is designed to measure liquid level in an aboveground storage tank. The gauge mounts on top of the tank and is activated

More information

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2 I&M NUMBER: 316-42-15-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

PARTS WASHER Model: CW1D Part No:

PARTS WASHER Model: CW1D Part No: PARTS WASHER Model: CW1D Part No: 7630900 OPERATING & MAINTENANCE INSTRUCTIONS GC01/12 INTRODUCTION Thank you for purchasing this CLARKE Parts Washer. Before using the product, be sure to read these instructions

More information

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. INSTALLATION, OPERATION & SERVICE MANUAL FOR COOLER TYPES OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. 1. Introduction This manual is a guide for the installation, maintenance

More information

FS10-R30 Flame Detector

FS10-R30 Flame Detector FS0-R0 Flame Detector Customer Product Manual Part 00-0 Issued 0/ For parts and technical support, call the Industrial Coating Systems Customer Support Center at (00) - or contact your local Nordson representative.

More information

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver Power Distribution Unit for IP-NINJAR PDU-1209 User s Guide Ver. 1.0.0 Thank you for choosing this IDK product. To ensure the best performance of this product, please read this User s Guide fully and carefully

More information

OPERATING & MAINTENANCE INSTRUCTIONS

OPERATING & MAINTENANCE INSTRUCTIONS PARTS WASHER MODEL NO: CW1D PART NO: 7630900 OPERATING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0318 REV 4 INTRODUCTION Thank you for selecting this CLARKE Parts Washer. Before using the product,

More information

NHR-25 Feed Hopper with Agitator

NHR-25 Feed Hopper with Agitator Instruction Sheet P/N 0920-02 Description This instruction sheet provides specifications, installation instructions, and parts lists for the NHR-25 Powder Feed Hopper with Agitator. This hopper is used

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at

More information

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 ) www.windsterhood.com User s Manual LINER SERIES WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 ) NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON

More information

Operating Instructions

Operating Instructions Operating Instructions BA-003 Read and understand this manual before use. Keep this manual for future reference. CONFORMS TO UL STD.No.1017 Certified to CSA STD C22.2 No.243-10 For questions or concerns

More information

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO: WARNING Read the instructions before using the machine PRESSURE WASHER MODEL NO: JETSTAR 1750 PART NO: 7333230 OPERATION & MAINTENANCE INSTRUCTIONS LS0711 INTRODUCTION Thank you for purchasing this CLARKE

More information

HR Powder Feed Hopper

HR Powder Feed Hopper Instruction Sheet P/N 106977E0 Description This instruction sheet provides specifications; installation and operation instructions; and parts lists for the HR-16-150 powder feed hopper. The hopper is shipped

More information

U7698E Flame Detector

U7698E Flame Detector U7698E Flame Detector Customer Product Manual Issued 3/02 NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments, and inquiries about its products. General

More information

INSTRUCTION MANUAL W-400

INSTRUCTION MANUAL W-400 USE and MAINTENANCE INSTRUCTION MANUAL Bellaria WBX WB GRAVITY SPRAY GUN Series LPH-400 WB en it fr es pt de se TECHNICAL DATA Classic Plus Series LPH-400 (LVLP) Classic Plus Nozzle_Needle set Combination

More information

PJ130S High Pressure Cleaner

PJ130S High Pressure Cleaner PJ130S High Pressure Cleaner Operator Manual Original instructions WARNING: Do not use the machine without reading the instruction sheet. Item Description OVERVIEW 1. High pressure washer 2. On/off switch

More information

JASOPELS ROTATING FLESHING MACHINE 1-BEAM

JASOPELS ROTATING FLESHING MACHINE 1-BEAM USER MANUAL JASOPELS ROTATING FLESHING MACHINE 1-BEAM ITEM NO. 32200067 Our quality Your choice 2 www.jasopels.com TABLE OF CONTENTS About this document... 3 Declaration of Conformity... 6 Safety... 6

More information

MOBILE PARTS WASHER MODEL No: CWM20

MOBILE PARTS WASHER MODEL No: CWM20 MOBILE PARTS WASHER MODEL No: CWM20 Part No: 7630925 OPERATING & MAINTENANCE INSTRUCTIONS GC0514 INTRODUCTION Thank you for purchasing this CLARKE mobile parts washer. Before use, please read this instruction

More information

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM TTC-1 TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION The nvent RAYCHEM TraceTek TTC-1 sensing module is used with TraceTek sensing cables to detect liquid leaks.

More information

MODEL NO: CW2D PART NO: OPERATING & MAINTENANCE INSTRUCTIONS

MODEL NO: CW2D PART NO: OPERATING & MAINTENANCE INSTRUCTIONS PARTS WASHER MODEL NO: CW2D PART NO: 7630910 OPERATING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0318 REV INTRODUCTION Thank you for selecting this CLARKE Parts Washer. Before using the product,

More information

G45 FastTrack. Page 1 of 8

G45 FastTrack. Page 1 of 8 Part# 1005364-02 5/3/2013 G45 FastTrack INSTRUCTIONS This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep

More information

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator.

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator. Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N260.3 - a 2.4 cu. ft., 3-way refrigerator. NORCOLD, Inc. P.O. Box 4248 Sidney, OH 45365-4248 Part No. 619260A (4-98) Table

More information

Propane Flame Projector Safety instructions and operating manual

Propane Flame Projector Safety instructions and operating manual Bigflame Propane Flame Projector Safety instructions and operating manual 1 Flame projector Bigflame Safety instructions Caution The directions in this manual must be followed strictly. It is imperative

More information

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions Operating Instructions Accessory Units Melitta Cafina XT Series Melitta Professional Coffee Solutions Contents General... 4. Manufacturer information... 4.2 About these instructions... 4.3 Explanation

More information

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN TTV 1500 / TTV 3000 EN OPERATING MANUAL CONVEYING FAN TRT-BA-TTV1500-3000-TC2016-26-004-EN Table of contents Notes regarding the operating manual... 2 You can download the current version of the operating

More information

PS-2/ES Automated pack & tag machine with IndES fastening system

PS-2/ES Automated pack & tag machine with IndES fastening system English Manual PS-2/ES Automated pack & tag machine with IndES fastening system Contents 1. Introduction 2. Important Safety Instructions 3. PS-2/ES 4. Unpacking the machine 5. Setting up the machine 6

More information

NH-4 Heaters. Customer Product Manual Part

NH-4 Heaters. Customer Product Manual Part NH-4 Heaters Customer Product Manual Part 039-0 Issued 03/7 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or contact your local Nordson representative.

More information

INSTRUCTION MANUAL MODEL: 690E

INSTRUCTION MANUAL MODEL: 690E 1 INSTRUCTION MANUAL ALEKO Drywall Sander MODEL: 690E READ THROUGH CAREFULLY AND UNDERSTAND THESE INSTRUCTIONS BEFORE USE Visit our web site for more great products, parts and accessories: 2 3 4 5 6 Caution!

More information

Instruction Manual Suppository Penetration Tester. Type PM 30

Instruction Manual Suppository Penetration Tester. Type PM 30 Instruction Manual Suppository Penetration Tester Type PM 30 ERWEKA GmbH * Ottostr. 20 22 * 63150 Heusenstamm * Germany * Tel: +49 (0) 6104 6903-0 Fax: +49 (0) 6104 6903-40 * E-mail: info@erweka.com *

More information

Operator s Manual CAYENNE HEAT N SERVE 4/3 RECTANGULAR RETHERMALIZER ENGLISH

Operator s Manual CAYENNE HEAT N SERVE 4/3 RECTANGULAR RETHERMALIZER ENGLISH CAYENNE HEAT N SERVE 4/ RECTANGULAR RETHERMALIZER Item Description Voltage Watts Amps Plug 2050 T4R Countertop without Drain 120 1600 1. 5-15P 2051 TD4R Countertop with Drain 120 1600 1. 5-15P 2 T4R Countertop

More information

Fill Sentry. Automated Fill System. Customer Product Manual Part A. NORDSON CORPORATION

Fill Sentry. Automated Fill System. Customer Product Manual Part A. NORDSON CORPORATION Fill Sentry Automated Fill System Customer Product Manual Part NORDSON CORPORATION www.nordson.com CAUTION: If this equipment is used with other Nordson equipment, refer to the manuals provided with that

More information

60In. Ceiling Fan. Owner s Manual

60In. Ceiling Fan. Owner s Manual 60In. Ceiling Fan Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may

More information

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. www.windsterhood.com User s Manual UNDER CABINET SERIES WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit is designed

More information

V SERIES HDR GAS RANGES

V SERIES HDR GAS RANGES SERVICE MANUAL ONE POWERFUL PACKAGE V SERIES HDR GAS RANGES TOPS Open Top Hot Top Griddle Top Work Surface BASES Standard Oven Convection Oven Cabinet Base - NOTICE - This manual is prepared for use by

More information

JDW Leaf Blower. EQ750 - Assembly Instructions. Please Read All Instructions Thoroughly Before Starting Assembly

JDW Leaf Blower. EQ750 - Assembly Instructions. Please Read All Instructions Thoroughly Before Starting Assembly JDW Leaf Blower EQ750 - Assembly Instructions Please Read All Instructions Thoroughly Before Starting Assembly 1 Components 1) Bottom Tube section 2) Rollers 3) Top Tube Section 4) Leaf collection bag

More information

3-1/2 Gallon Parts Washer

3-1/2 Gallon Parts Washer 3-1/2 Gallon Parts Washer Model 38347 Assembly and Operating Instructions 3491 Mission Oaks Blvd., Camarillo, CA 93011 Copyright 1998 by Harbor Freight Tools. All rights reserved. No portion of this manual

More information

MST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL

MST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL MST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL IMPORTANT WARNING WHEN THE OXYGEN MONITOR IS CORRECTLY INSTALLED AND MAINTAINED, IT MONITORS THE LEVEL OF OXYGEN IN ITS SURROUNDINGS 07/11

More information

NHR-2-25 NHR-2-50 NHR-2-80 NHR-8-80 Powder Capacity: 11 kg (25 lb) 23 kg (50 lb) 36 kg (80 lb) 36 kg (80 lb) *Pump Knockouts: *Pump Adapters

NHR-2-25 NHR-2-50 NHR-2-80 NHR-8-80 Powder Capacity: 11 kg (25 lb) 23 kg (50 lb) 36 kg (80 lb) 36 kg (80 lb) *Pump Knockouts: *Pump Adapters Instruction Sheet P/N 069-0 WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. WARNING: Wear an

More information

PME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies

PME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies PME Series Enclosures Battery Enclosure (BE) Field Upgrade Installation Instructions Effective: January, 2004 Alpha Technologies Power Alpha Technologies. Protecting The Power in Communications. Preface

More information

USE and MAINTENANCE INSTRUCTION MANUAL GRAVITY. WS-400 EVO LS-400 Entech. SPRAY GUN Series. en it fr es pt de se

USE and MAINTENANCE INSTRUCTION MANUAL GRAVITY. WS-400 EVO LS-400 Entech. SPRAY GUN Series. en it fr es pt de se USE and MAINTANCE INSTRUCTION MANUAL WS-400 EVO LS-400 Entech GRAVITY SPRAY GUN Series en it fr es pt de se TECHNICAL DATA WS-400 WS-400 EVO WS-400 Clear WS-400 Base WS-400-1301 EVO 1.3 170 365 260 WS-400-1401

More information

HOT WASHER MODEL NO: KING150

HOT WASHER MODEL NO: KING150 WARNING: Do not use the hot washer without reading this manual HOT WASHER MODEL NO: KING150 PART NO: 7320175 OPERATION & MAINTENANCE INSTRUCTIONS LS1215 INTRODUCTION Thank you for purchasing this CLARKE

More information

XC-18. NOTE: *Machine shown without Lift-Up Safety Guard. This guard is included with machine. Machine should not be operated without this guard.

XC-18. NOTE: *Machine shown without Lift-Up Safety Guard. This guard is included with machine. Machine should not be operated without this guard. XC-18 NOTE: *Machine shown without Lift-Up Safety Guard. This guard is included with machine. Machine should not be operated without this guard. EXTREMA MACHINERY COMPANY, INC. PO BOX 1450, ALBANY, LOUISIANA

More information

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with T-style cordsets.

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with T-style cordsets. Electrical System - Section Electrical System NOTE: This section applies to applicators with T-style cordsets. Table of Contents Electrical System........................................... - Introduction................................................

More information

A measured step forward

A measured step forward A measured step forward Operations & Maintenance Manual TM JESCO UV 405-412-440-450-480-550-80 2 LCD LCD PLUS Contents 1. Introduction...3 2. General Principles and Safety Instructions...4 3. Instructions

More information

Operator s Manual. Wet/Dry Vacuum with Detachable Blower 12 Gallon Model No. VBV1210 FOR YOUR SAFETY

Operator s Manual. Wet/Dry Vacuum with Detachable Blower 12 Gallon Model No. VBV1210 FOR YOUR SAFETY Wet/Dry Vacuums Operator s Manual Wet/Dry Vacuum with Detachable Blower 12 Gallon Model No. VBV1210 FOR YOUR SAFETY Read and understand this manual before use Keep this manual for future reference www.vacmaster.com

More information

NHR-2-25 NHR-2-50 NHR-2-80 NHR-8-80 Powder Capacity: 11 kg (25 lb) 23 kg (50 lb) 36 kg (80 lb) 36 kg (80 lb) *Pump Knockouts: *Pump Adapters

NHR-2-25 NHR-2-50 NHR-2-80 NHR-8-80 Powder Capacity: 11 kg (25 lb) 23 kg (50 lb) 36 kg (80 lb) 36 kg (80 lb) *Pump Knockouts: *Pump Adapters Instruction Sheet P/N 069A WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Description This

More information

USER S MANUAL ATH WH220

USER S MANUAL ATH WH220 USER S MANUAL ATH WH220 INDEX INTRODUCTION... - 3 - General information s... - 3 - Description of pneumatic jack... - 4 - Operation of jack... - 5 - Technical data... - 6 - Dimension drawing... - 6 - INSTALLATION...

More information

690 Power Fishing System

690 Power Fishing System INSTRUCTION MANUAL 3N51 690 Power Fishing System Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register this product at www.greenlee.com

More information

Have a Question? Call toll-free: Owners Manual L WARNING. Project Series Paint Sprayers Important Safety Instructions

Have a Question? Call toll-free: Owners Manual L WARNING. Project Series Paint Sprayers Important Safety Instructions Owners Manual 333394L EN Project Series Paint Sprayers Important Safety Instructions Read all warnings and instructions in this manual and on the unit, including the power cord. Be familiar with the controls

More information

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL IMPORTANT WARNING WHEN THE CO MONITOR IS CORRECTLY INSTALLED AND MAINTAINED, IT MONITORS THE LEVEL OF CARBON MONOXIDE IN THE RESPIRATORY AIR

More information

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm Operating & Maintenance Manual Alert-4 Ethernet LCD Master Alarm w w w. a m i c o. c o m Contents User Responsibility 4 Introduction 4 Features 5 Description of the Alarm 5 Shipment Details 5 The Alarm

More information

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them. K 1.100 Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them. www.kaercher.com/register-and-win 59651430 (10/13) Contents General information..............

More information

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system INSTRUCTION MANUAL 1MN0107 REV. 0 operates with ISO9001 certified quality system TECSYSTEM S.r.l. 20094 Corsico (MI) Tel.: +39-024581861 Fax: +39-0248600783 http://www.tecsystem.it R. 1.1 25/08/16 ENGLISH

More information

R100 Oil-Less Refrigerant Recovery Unit

R100 Oil-Less Refrigerant Recovery Unit R100 Oil-Less Refrigerant Recovery Unit Operation Manual 1 INTRODUCTION Welcome to simple, efficient refrigerant recovery with your new YELLOW JACKET Refrigerant Recovery Unit, R100. This unit combines

More information

Operations and Safety Manual

Operations and Safety Manual Tuffy Jr. Heated Soil Extractor Operations and Safety Manual BEFORE YOU START: SAFETY OPERATION SERVICE PARTS TROUBLESHOOTING RETURN GOODS POLICY! READ and UNDERSTAND this material before operating or

More information

17 U.S. gallon portable low profile drain with electric pump

17 U.S. gallon portable low profile drain with electric pump Assembly and operation instructions 17 U.S. gallon portable low profile drain with electric pump Model 3669 Date of issue February 2018 Form number 404513 Version 2 Contents Safety...........................

More information

AVANI Grinding Booth

AVANI Grinding Booth AVANI Grinding Booth GB-6066-DD Customer: Kelly Walsh Customer PO#: 11305 AVANI SO#: Serial #: 153920-153921 Ship Date / Install Date: Tested By: Please read and save these instructions. Read carefully

More information

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL IMPORTANT WARNING WHEN THE CO MONITOR IS CORRECTLY INSTALLED AND MAINTAINED, IT MONITORS THE LEVEL OF CARBON MONOXIDE IN ITS SURROUNDINGS..

More information

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00 I&M NUMBER: 316-42-5-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Watlow heaters are built to comply with UL and CSA dielectric requirements, it may be

More information

SAFETY AND OPERATING MANUAL. Original Instructions 5.0

SAFETY AND OPERATING MANUAL. Original Instructions 5.0 SAFETY AND OPERATING MANUAL Original Instructions 5.0 Read all safety warnings and all instructions before use. Failure to follow the warnings and instructions may result in electric shock, fire and/or

More information

en Hydronic Surface Heater E 1100 REPAIR MANUAL

en Hydronic Surface Heater E 1100 REPAIR MANUAL 0176742en 002 0209 Hydronic Surface Heater REPAIR MANUAL 0 1 7 6 7 4 2 E N Foreword Foreword Machines covered by this manual Machine Item Number 0620172 0620244 Machine documentation Keep a copy of the

More information

Friwa Compact. Operating instructions EN

Friwa Compact. Operating instructions EN Operating instructions EN Version 1.1 / Edition 09/2013 Contents 1 Key background information... 3 1.1 Limitation of liability... 3 1.2 Responsibilities of the operator... 3 1.3 Documentation... 3 1.3.1

More information

APW-VAP-150P High Pressure Cleaner Operator Manual

APW-VAP-150P High Pressure Cleaner Operator Manual APW-VAP-150P High Pressure Cleaner Operator Manual BEFORE OPERATING THIS APPLIANCE PLEASE READ THESE INSTRUCTIONS CAREFULLY Item Description OVERVIEW 1. High pressure washer 2. On/off switch 3. Water outlet

More information

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to

More information

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650 USER GUIDE PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650 AB0039 FOR RESIDENTIAL USE ONLY!! MODELS SFDB-DQ, SFDB-DR AND SFDB-DS 30042509E IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

More information

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

User Manual GV25 GV35 GV702. Company information:   Original instructions GV12066 (1) User Manual Original instructions GV25 GV35 GV702 Company information: www.vipercleaning.eu info-eu@vipercleaning.com GV12066 (1) 2012-04-10 USER MANUAL ENGLISH TABLE OF CONTENTS Introduction... 4 Manual

More information

P4200PM / P5000PM Remote Air Dryer User s Guide

P4200PM / P5000PM Remote Air Dryer User s Guide P4200PM / P5000PM Remote Air Dryer User s Guide 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS P4200PM / P5000PM Air Dryer! We here at PUREGAS are very proud of our products

More information

POWER SWEEP N VAC 1800W Model No. 101BV1800

POWER SWEEP N VAC 1800W Model No. 101BV1800 POWER SWEEP N VAC 1800W Model No. 101BV1800 Operator s Manual WARNING To reduce the risk of injury, the user must read and understand the Operator s Manual. Save this manual. Introduction Thank you for

More information

Service Manual Model 3163

Service Manual Model 3163 Service Manual Model 3163 Contents Important Safety Information.......... 1 Specifications.................. 2 General Information.............. 2 Direct Vent Requirements........... 2 Propane System................

More information

Bar Fridge USER MANUAL MB46W

Bar Fridge USER MANUAL MB46W Bar Fridge USER MANUAL MB46W CONTENTS Safety information... 2-3 Identifying parts of the fridge... 4 Transporting... 5 Installation... 5 Reversing the door... 6 Operating instructions... 7 Cleaning &

More information

R Series B & T2 Model

R Series B & T2 Model FRONT R Series B & T2 Model Fan Forced Wall Heaters 4-1/4 (108mm) NOTE: Knockouts in top same dimensions 3-1/4 3-1/4 (108mm) (108mm) as bottom 16-7/8 (429mm) 13-7/8 (352mm) BOTTOM 13-7/8 (352mm) 7-3/4

More information

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391 Harbor Breeze Harb or Breeze ITEM #0915543 BUILDER S SERIES CEILING FAN MODEL #41391 Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. Español p. 18 ATTACH YOUR RECEIPT HERE Purchase

More information

Operator s Manual. 2.5 Gallon Model No. VOM205P FOR YOUR SAFETY. Read and understand this manual before use. Keep this manual for future reference.

Operator s Manual. 2.5 Gallon Model No. VOM205P FOR YOUR SAFETY. Read and understand this manual before use. Keep this manual for future reference. Wet/Dry Vacuums Operator s Manual 2.5 Gallon Model No. VOM205P FOR YOUR SAFETY Read and understand this manual before use. Keep this manual for future reference. www.vacmaster.com Cleva North America 44

More information

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00 I&M NUMBER: 316-42-16-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

Inverter Split-type Room Air Conditioner

Inverter Split-type Room Air Conditioner OWNER S MANUAL Inverter Split-type Room Air Conditioner Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.

More information

Specifications: NORTH AMERICA

Specifications: NORTH AMERICA Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information.

More information

X T1220 LED FOG MACHINE USER MANUAL

X T1220 LED FOG MACHINE USER MANUAL X T1220 LED FOG MACHINE USER MANUAL Product Description: X-T1220 LED Fog Machine: Its compact body, stable and practical performance, fog with dazzling RGBA LED lights. Features: 1: Practical, compact

More information

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP) INDUSTRIAL - SOLVENT PARTS CLEANER OPERATION & INSTRUCTION MANUAL I. Introduction A. Manufacturer s Statement CM200 (115V OR 230V PUMP) This manual will provide you with important information about the

More information

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Installing the Cisco ONS FAP-4 Fuse Alarm Panel Installing the Cisco ONS 15454-FAP-4 Fuse Alarm Panel Product Number: 15454-FAP-4= This document explains how to install, test, operate, and maintain the Cisco ONS 15454-FAP-4 fuse alarm panel. This document

More information

INSTRUCTION MANUAL 4HP WET / DRY VACUUM VC V 60 Hz 7A. Gal

INSTRUCTION MANUAL 4HP WET / DRY VACUUM VC V 60 Hz 7A. Gal INSTRUCTION MANUAL WET / DRY VACUUM VC25180 Note : Read and understand this manual before use. Keep this manual for future reference. 4HP 8 Gal 120 V 60 Hz 7A C US TABLE OF CONTENTS SECTION Warranty...

More information