1 Product Data Sheet Absolute and Gage Pressure Transmitter ATRADITION OF EXCELLENCE IN THE PULP AND PAPER INDUSTRY Mounts flush to process media -inch flush mount compatible with a PMC process connection, or /2-inch threaded mounting connection Absolute or gage pressure ranges from 0 to psi Optional scaleable LCD meter Communicates via the HART protocol 20: turndown on smart option External zero and span adjustments 0.20% reference accuracy, including linearity, hysteresis, and repeatability Over 35 years of experience and the finest network of service and support in the industry Stable, reliable, and easy to maintain NEW OFFERING! PROVEN ROSEMOUNT RELIABILITY AND STABILITY The Rosemount Pressure Transmitter provides stable, reliable service for applications that require flush mounting to the process media. The was designed by Rosemount Inc., the most trusted name in process control, for the pulp and paper industry and similar applications where process clogging is aconcern. ONE-INCH FLUSH MOUNT PROCESS CONNECTION Rosemount Inc. now offers aone-inch flush mount option on the Smarttransmitter. This new option is compatible with a PMC process connection, and requires no retrofitting for existing one-inch fittings. Simply remove the old transmitter and replace it with the new one. When you replace your old transmitter with the new,high performance one-inch flush mount transmitter, not only do youget superior Rosemountperformance, youget it with practically no installation costs. 22 Pressure-22

2 Absolute and Gage Pressure Transmitter Introducing the One-Inch Flush Mount Fitting Now you can have superior Rosemount technology without having to retrofit a new transmitter. The new smart transmitter with the one-inch flush mount process connection can be installed in any existing one-inch flush mount fitting without the cost of replumbing. The one-inch process connection is also available with a weld-on nipple assembly option for new installations. If your old system has the standard one-inch flush mount design, there has never been a better time to upgrade to Rosemount technology. The with the one-inch flush mount process connection comes equipped with these standard features: Easy Installation for existing one-inch mounts 3-hole rotational mounting flexibility HART communication compatibility 0 50 psi with 20: rangeability Local zero/span or remote calibration capability Viton O-ring for use with a wide variety of process fluids Optional LCD meter for local display of process pressure SUPERIOR FUNCTIONALITY The design incorporates a process connection that positions the isolating diaphragm of the transmitter flush with the vessel wall. This design eliminates clogging problems associated with traditional transmitters used in highly viscous processes that tend to crystallize, polymerize, or precipitate, such as those in the pulp and paper industry. Its small size and rugged, in-line construction make it ideal for paper mill applications on stock lines, refiners, screens, cleaners, vacuum boxes, and vented tanks. SUPERIOR ROSEMOUNT DESIGN Two-compartment housing provides a junction box for easy access to test terminals and RFI protection, and a separate airtight electronics housing which allows easy replacement of the circuit board. Optional LCD meter. Provides readout directly from the transmitter (See Figure 2). The Rosemount has these technologically advanced features: HART protocol compatibility. The Model 2090P has full smart communication capabilities via the HART Communicator. Microprocessor-based circuitry ensures excellent performance by optimizing sensor linearity and reducing the external influences of temperature. Each transmitter is factory characterized to deliver exceptional performance. Unique silicon-based resistance sensing element is a Rosemount-patented thin-film, polysilicon sensor that guarantees excellent performance and stability in harsh environments (see Figure ). Resistance Element Environmentally Sealed Isolating Diaphragm FIGURE. Patented Sensing Element B05A Pressure-222

3 Rosemount Inc. Zero Elevation and Suppression Zero can be suppressed between atmosphere (2090PG), or 0 psia (2090PA) and upper range limit, provided the calibrated span is equal to or greater than the minimum span, and the upper range value does not exceed the upper range limit. The Model 2090PG, in either the analog or smart versions, does not do vacuum calibrations. FIGURE 2. One-Inch Flush Mount Option with Optional LCD Meter AB Overpressure Limits Range : 20 psig. Range 2: 300 psig. Range 3:,600 psig. Temperature Limits Process: s A & C: 40 to 250 F ( 40 to 2 C). s D & G: 4 to 250 F ( 20 C to 2 C). Ambient: All s: 4 to 85 F ( 20 to 85 C). Storage: All s: 50 to 85 F ( 46 to 85 C). Process temperatures above 85 F (85 C) require derating the ambient limits by a.5: ratio. Maximum Ambient Temperature in F ( Process Temp 85) = SPECIFICATIONS Maximum Ambient Temperature in C = ( Process Temp 85) Functional Specifications Service Liquid, gas, vapor, and high-viscosity applications. Ranges Ranges 2 3 Min. Span (Smart).5 psi (03 mbar) 7.5 psi (57 mbar) 40 psi (2.76 bar) URL/Max. Span. Sensor Limit 30 psi (2.06 bar) 50 psi (0.34 bar) 300 psi (20.68 bar) Output 4 20 ma dc/digital HART Protocol. Rangedown 20:. Load Limitations Reverse polarity protection is standard. Maximum loop resistance is determined by the power supply voltage as described by the following equation: Max. Loop Resistance = 43.5 (Power Supply Voltage 0.5) Load (ohms) Operating Region Power Supply Output S (dc Volts) () For hazardous location approvals, power supply must not exceed 36 V. Humidity Limits 0 00% relative humidity. Volumetric Displacement Less than cm 3. Turn-on Time 2.0 seconds, no warm-up required. Failure Alarm If self-diagnostics detect a sensor or microprocessor failure, the analog signal is driven either high or low to alert the user. High or low failure mode is user-selectable with a jumper on the transmitter. The values to which the transmitter drives its output in failure mode depend on whether it is factory-configured to standard or NAMUR-compliant operation. The values for each are as follows: Standard Operation linear output:3.9 I 20.8 fail high:i 2.75 ma low:i 3.75 ma NAMUR-Compliant Operation linear output:3.8 I fail high:i 22.5 ma. low:i 3.6 ma. Transmitter Security Activating the transmitter security function prevents changes to the transmitter configuration, including local zero and span adjustments. Security is activated by an internal switch. 223 Pressure-223

4 Absolute and Gage Pressure Transmitter Ordinary Location Certification Factory Mutual (FM) Approval As standard, the transmitter has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). Hazardous Locations Certifications Hazardous Locations Certifications Pending for Model 2088F Smart (Option S). Factory Mutual (FM) Approvals E5 Explosion Proof for Class I, Division, Groups B, C, and D. Dust-Ignition Proof for Class II, Division, Groups E, F, and G. Suitable for Class III, Division, indoor and outdoor (NEMA 4X) hazardous locations; factory sealed. I5 Instrinsically safe for use in Class I, Division, Groups A, B, C, D; Class II, Division, Groups E, F, and G; and Class III, Division when connected in accordance with Rosemount drawing Non-incendive for Class I, Division 2, Groups A, B, C, and D. K5 Combination of E5 and I5. I5 Connection Parameters FM I5 Connection Parameters V max =30Vdc I max = 65 ma I max = 225 ma P max =W Ci = 0.02 ÿþ Li = 20 þ Canadian Standards Association (CSA) Approvals C6 Explosion Proof for Class I, Division, Groups B, C, and D. Dust-Ignition Proof for Class II, Division, Groups E, F, and G. Suitable for Class III, indoor and outdoor hazardous locations, CSA enclosure Type 4X; factory sealed. Approved for Class I, Division 2, Groups A, B, C, and D. Intrinsically Safe for Class I, Division, Groups A, B, C, and D. Temp. T3C. (Intrinsically safe when connected with approved barriers in accordance with Rosemount drawing ) CSA I. S. Connection Parameters CSA I. S. Connection Parameters V max =30Vdc/R min =330Ohms V max =28Vdc/R min =300Ohms V max =25Vdc/R min =200Ohms V max =22Vdc/R min =80Ohms V max =30Vdc/R min =50Ohms Approved Groups C G Approved Groups A, B, C, D A, B, C, D A, B, C, D A, B, C, D C, D British Approvals Service for Electrical Equipment in Flammable atmospheres (BASEEFA) Approvals I BASEEFA/CENELEC Intrinsic Safety (Ex 97D2276X). EEx ia IIC T5 (T amb = 55 to 40 C) EEx ia IIC T4 (T amb = 55 to 70 C) BASEEFA I Connection Parameters BASEEFA I Connection Parameters V max:in =30Vdc I max:in =200mA W max:in =0.9W C eq = 0.02mF N BASEEFA Type N Certification (Ex 97Y4277X) Ex N IIC T5 (T amb = 40 to 70 C) Special Conditions for Safe Use with Transient Terminal Block (T) When the optional transient protection terminal block is installed, the apparatus is not capable of withstanding a 500 V r.m.s. test to case. This must be taken into account on any installation in which it is used, for example, by assuring that the supply to the apparatus is galvanically isolated. KEMA/CENELEC Explosionproof ED Certification (97ATEX2378) EEx d.iic T4 (T amb = 80 C) EEx d.iic T6 (T amb = 40 C) Performance Specifications (Zero-based spans, reference conditions, and 36 SST isolating diaphragm.) Reference Accuracy ±0.20% of calibrated span. Includes combined effects of linearity, hysteresis, and repeatability. Ambient Temperature Effect per 00 F (56 C) ±(0.3% URL + 0.3% of span) from 40 to 85 F ( 40 to 85 C). Stability ±0.0% of upper range limit for 2 months. Time Response Less than 200 ms time constant (63.2% response to a step change in pressure). Vibration Effect Less than ±0.% of upper range limit when subjected to vibration of: peak to peak constant displacement of 4 mm (5 5 Hz) and constant acceleration of 2 g (5 50 Hz) and g ( Hz). Power Supply Effect Less than 0.0% of calibrated span per volt. Mounting Position Effect Zero shift of up to.2 inh 2 O (0.3 kpa), which can be calibrated out. No span effect. Pressure-224

5 Rosemount Inc. RFI Effect Less than ±0.25% of upper range limit from MHz at 30 V/m with leads in conduit. Less than ±0.25% of upper range limit at 0 V/m with unshielded twisted pair (no conduit). Physical Specifications Electrical Connection /2 4 NPT, M20.5 (CM20), or PG 3.5 conduit entry. Process Wetted Parts Isolating Diaphragm 36L stainless steel. Process Connector 36L stainless steel. Process Connector Gasket TFE. Process Connection Size /2.5 NPT or -in. Flush Mount. Non-wetted Parts Electronics Housing Low-copper aluminum, NEMA 4X, IP65, IP67, CSA enclosure Type 4X. Paint Polyurethane. Cover O-rings Buna-N. Process O-rings Standard: Viton. Optional: Buna-N or Ethylene propylene. Fill Fluid Silicone oil. Weight Approximately 2.96 lb (.34 kg). 5.0 (25) 4.3 (0) max. Optional Meter Cover External Zero/Span under Nameplate 3.9 (00) Nameplate Terminal Connections Side Transmitter Circuitry Side 4.7 (40) 5.75 (46) 3X 5 /6 8 UNC Mounting Holes for Rotational.03 (26.2) 2X /4 20 UNC 2BX 0.60 Deep Mounting Bracket Holes Weld Spud.0 (25.4) 0.7 (7.8).05 (26.6).32 (33.4) Vessel Wall O-ring (Viton standard) FIGURE 3. One-Inch Flush Mount Dimensional Drawing. Pressure-225

6 Absolute Gage and Pressure Transmitter Nameplate External Zero/Span Electronics Housing Assembly Terminal Block Cover O-Ring Electronics Module Teflon Gasket Weld Spud Alarm Output Switch LCD Security Switch OPTIONAL SMART LCD METER A8A, 2088A08P FIGURE 4. Smart Exploded View and Optional LCD Meter. 5.0 (25) 4.3 (0) Max Optional Meter Cover 3.9 (00) Nameplate Terminal Connections Transmitter Circuitry 4.7 (40) 5.4 (40) Typical M44.25 Weld Spud 2.37 (54) 0.82 (2) 2 /4 20 UNC 2BX Depth 0.60 Mounting Bracket Holes Vessel Wall /2 4 NPT Female Process Connection Stress Isolator Groove A07P, B07P Pressure-226 FIGURE 5. Smart Transmitter Dimensional Drawings.

7 Rosemount Inc. ORDERING INFORMATION Model Product Description 2090PA 2090PG Absolute Pressure Transmitter Gage Pressure Transmitter Range psi (0 2 bar) 0 50 psi (0 0.3 bar) psi ( bar) Ranges 2 3 Min. Span (Smart).5 psi (03 mbar) 7.5 psi (57 mbar) 40 psi (2.76 bar) URL/Max. Span. Sensor Limit 30 psi (2.06 bar) 50 psi (0.34 bar) 300 psi (20.68 bar) Output S 4 20 ma dc/digital HART Protocol MATERIALS OF CONSTRUCTION Process Connection Isolating Diaphragm Oil Fill SST 36 SST Silicone A C () D (2) G (2 Process Connection /2 in. Threaded, No Weld Spud, /2 in. Teflon Gasket /2 in. Threaded, 36 SST Weld Spud with Stress Isolation and Teflon Gasket in. Flush Mount (available with Gage Pressure, Range 2, and Smart Output Option s only) in. Flush Mount with weld-on nipple (available with Gage Pressure, Range 2, and Smart Output Option s only) C6 E5 I5 I N K5 ED M5 M7 B4 T Q4 C4 P2 Q8 W2 W3 Conduit Thread ½ 4 NPT M20.5 (CM20) Female PG 3.5 G /2 Female (PF /2 Female) Options Hazardous Locations Approvals Canadian Standards Association (CSA) Explosion-Proof, Intrinsic Safety, and Non-Incendive Approval Factory Mutual (FM) Explosion-Proof Approval Factory Mutual (FM) Non-Incendive and Intrinsic Safety Approval (Entity Concept) BASEEFA Intrinsic Safety Certification BASEEFA Type N Certification E5 and I5 Combination KEMA (CENELEC) Flame-Proof Approval Accessory Options LCD Meter LCD Meter (Special Configuration) SST Mounting Bracket with SST Bolts Transient Protection Terminal Block Other Options Calibration Data Sheet NAMUR Compliant Alarm Levels (smart option only) Cleaning for Special Service Material Traceability per DIN 3.B Buna-N O-ring Process Connection (available with Process s D and G only) Ethylene Propylene O-ring Process Connection (available with Process s D and G only) Typical Model Number: 2090PG 2 S 22 A () Flameproof hazardous location approvals not available. 998 Rosemount Inc. May be protected by one or more of the following U.S. Pat. Nos. 4,970,898 and 5,083,09. May depend on model. Other U.S. and foreign patents issued and pending. Pressure-227

8 PRINTED Absolute and Gage Pressure Transmitter Standard Configuration Unless otherwise specified, transmitter is shipped as follows: Engineering units: psi 4 ma: 0 psi 20 ma: Upper Range Limit Alarm Output S: High LCD Meter: 0 00% Custom Configuration Calibration Transmitters are factory calibrated to customer's specified range. If calibration is not specified, transmitters are calibrated at maximum range. Calibration is at ambient temperature and pressure. Tagging The transmitter will be tagged, at no charge, in accordance with customer requirements. All tags are stainless steel. The standard tag is wired to the transmitter. Tag character height is /8 in. (0.38 cm). A permanently attached tag is available upon request. /4 8 NPT FIGURE 6. Calibration Adapter. Note Different Part Numbers for Different Process Connection s. FIGURE SST Plug/Heat Sink for Process Connection s A and C C03A B03A Accessories TABLE. Accessories. Item Description Calibration Adapter () (Figure 6) Usetoconnectacalibrationdevice to a transmitter. 36 SST Plug/Heat Sink () (Figure 7) Use during installation to prevent welding damage. Flush Mount Calibration Adapter (2) (Figure 6) Usetoconnectacalibrationdevicetothe PMC mounting. /2-in. Threaded Weld Spud Kit (Figure 5) Includes Teflon O-ring. () Process Connection s A and C only. (2) Process Connection s D and G only. Part Number Flush Mount Weld Spud (2) (Figure 8) FIGURE 8. Weld Spud for Process Connection s D and G. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. Hastelloy C-276 is a registered trademarks of Cabot Corp. Teflon and Viton are registered trademarks of E.I. du Pont de Nemours & Co. PMC is a registered trademark of Paper Machine Components, Inc. Cover photo: AB, B C03D Rosemount Inc Market Boulevard Chanhassen, MN 5537 USA Tel Telex Fax (62) IN 998 Rosemount Inc. U.S. A J Rev. CA /98 Fisher-Rosemount Limited Heath Place Bognor Regis West Sussex PO22 9SH England Tel 44 (243) Fax 44 (243) Fisher-Rosemount Singapore Pte Ltd. Pandan Crescent Singapore 2846 Tel (65) Fax (65) Tlx RS 67 FRSPL Pressure-228

Sanitary Pressure Transmitter

Sanitary Pressure Transmitter Product Data Sheet 00813-0100-4698 Sanitary Pressure Transmitter A TRADITION OF EXCELLENCE IN PERFORMANCE Absolute or gage pressure ranges from 0 3 to 0 800 psi 0.20% reference accuracy, including linearity,

More information

Rosemount 2090P Pulp and Paper Pressure Transmitter

Rosemount 2090P Pulp and Paper Pressure Transmitter Product Data Sheet Rosemount 2090P Pulp and Paper Pressure Transmitter Rosemount 2090P 1-inch flush mount compatible with a PMC process connection, or 1 1 /2-inch threaded mounting connection Absolute

More information

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 2090F Hygienic Pressure Transmitter Hygienic Pressure Transmitter Conforms to 3-A Sanitary s Features CIP/SIP service for process temperatures up to 284 F (140 C) Absolute or gage pressure ranges from 0-1.5 to 0-300 psi Mounts with either

More information

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol Sanitary Pressure Transmitter with HART Protocol A TRADITION OF EXCELLENCE IN PERFORMANCE Conforms to 3-A Sanitary Standards Features CIP/SIP service with an upper temperature limit of 284 F (140 C) USDA

More information

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 2088 Absolute and Gage Pressure Transmitter Product Data Sheet Rosemount 2088 Rosemount 2088 Absolute and Gage Pressure Transmitter Absolute and gage pressure ranges from 0 1.5 psi to 0 4,000 psi (0 0.1 to 0 276 bar) Performance of 0.075% with high

More information

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 2088 Absolute and Gage Pressure Transmitter Product Data Sheet Rosemount 2088 Rosemount 2088 Absolute and Gage Pressure Transmitter Performance of 0.075% with High Accuracy option Lightweight, compact design for cost effective installation Protocols

More information

Rosemount 4500 Hygienic Pressure Transmitter

Rosemount 4500 Hygienic Pressure Transmitter Product Data Sheet Rosemount 4500 Rosemount 4500 Hygienic Pressure Transmitter Hygienic design conforms to 3-A and EHEDG standards Demonstrated best-in-class performance during SIP/CIP for process temperatures

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C) Product Data Sheet December 2012 00813-0100-4027, Rev BB Rosemount 4500 Hygienic Pressure Transmitter ProductDiscontinued R 37-01 Hygienic design conforms to 3-A and EHEDG standards Demonstrated best-in-class

More information

Rosemount 752 Fieldbus Remote Indicator

Rosemount 752 Fieldbus Remote Indicator Product Data Sheet Rosemount 752 Rosemount 752 Fieldbus Remote Indicator ROSEMOUNT 752 DELIVERS: Two-wire segment powered device Displays up to 8 values Link Master Capability Optional PID, Characterizer,

More information

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical

More information

Annubar Flowmeter Series

Annubar Flowmeter Series Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 2090F Hygienic Pressure Transmitter Rosemount 2090F Hygienic Pressure Transmitter Product Data Sheet December 2017 00813-0100-4698, Rev GA Conforms to 3-A Sanitary Standards Features CIP/SIP service for process temperatures up to 284 F (140

More information

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 2090F Hygienic Pressure Transmitter Rosemount 2090F Hygienic Pressure Transmitter Product Data Sheet November 2016 00813-0100-4698, Rev FC Conforms to 3-A Sanitary Standards Features CIP/SIP service for process temperatures up to 284 F (140

More information

Rosemount 4500 Hygienic Pressure Transmitter. Start

Rosemount 4500 Hygienic Pressure Transmitter. Start Quick Installation Guide June 2007 Rosemount 4500 Rosemount 4500 Hygienic Pressure Transmitter ProductDiscontinued Start Step 1: Mount the Transmitter Step 2: Set the Switches Step 3: Connect Wiring and

More information

MODEL APT 3700N. Smart Pressure Transmitter For Nuclear Service. Duon System Co., Ltd. for Differential / Gauge / Absolute Pressure Measurement

MODEL APT 3700N. Smart Pressure Transmitter For Nuclear Service. Duon System Co., Ltd. for Differential / Gauge / Absolute Pressure Measurement DOC. NO. : 3700N-E01I For Nuclear Service for Differential / Gauge / Absolute Pressure Measurement MODEL APT 3700N (GASAN-DONG), 232, BEOTKKOT-RO GUMCHON-GU SEOUL KOREA Tel : +82-2-860-7900 Fax : +82-2-860-7997

More information

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

Rosemount 2088, 2090P, and 2090F Pressure Transmitters April 2013 Rosemount 2088 and 2090 Rosemount 2088, 2090P, and 2090F Pressure Transmitters with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol Start Step 1: Mount the Transmitter Step 2: Set the Jumpers

More information

Rosemount 4600 Oil & Gas Panel Pressure Transmitter

Rosemount 4600 Oil & Gas Panel Pressure Transmitter Product Data Sheet October 2017 00813-0100-4022, Rev LA Rosemount 4600 Oil & Gas Panel Pressure Transmitter A compact, lightweight, all-welded stainless steel design Up to 40:1 rangeability for increased

More information

Rosemount 3100 Series Ultrasonic Level Transmitters

Rosemount 3100 Series Ultrasonic Level Transmitters Product Data Sheet Ultrasonic Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for on-site programming Continuous measurement of level or distance-to-surface.

More information

Rosemount 2051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol

Rosemount 2051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol Quick Installation Guide August 2009 Rosemount 2051 Rosemount 2051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol Start Step 1: Mount the Transmitter Step 2: Consider Housing

More information

Rosemount 3095MFC Compact Orifice Mass Flowmeter

Rosemount 3095MFC Compact Orifice Mass Flowmeter Rosemount 3095MFC Compact Orifice Mass Flowmeter SPECIFICATIONS Performance System Reference Accuracy Percent (%) of mass flow rate TABLE 11. 3095MFC Compact Orifice Mass Flowmeter TYPE Repeatability ±0.1%

More information

Rosemount 3051 Pressure Transmitter Includes Transmitter Option TR ProductDiscontinued. Start

Rosemount 3051 Pressure Transmitter Includes Transmitter Option TR ProductDiscontinued. Start Quick Installation Guide June 2009 Rosemount 3051 Rosemount 3051 Pressure Transmitter Includes Transmitter Option TR ProductDiscontinued Start Step 1: Mount the Transmitter Step 2: Consider Housing Rotation

More information

Rosemount 2051T In-Line Pressure Transmitter

Rosemount 2051T In-Line Pressure Transmitter Rosemount 2051T In-Line Pressure Transmitter 2051T In-Line Wireless Pressure Transmitter Configuration Transmitter Output Code 4-20 ma HART 2051 A 2051 with Selectable HART (1) Lower Power 2051 2051 with

More information

Rosemount 3051L Level Transmitter

Rosemount 3051L Level Transmitter Rosemount 3051 December 2013 Rosemount 3051L Level Transmitter The Rosemount 3051L Level transmitter combines the performance and capabilities of Rosemount 3051 transmitters with the reliability and quality

More information

Rosemount 3051 Pressure Transmitter

Rosemount 3051 Pressure Transmitter Quick Start Guide 00825-0100-4001, rev. JA Rosemount 3051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc Low Power Protocol Rosemount 3051CF Series Flowmeter Transmitter with 4-20 ma HART and 1-5 Vdc

More information

Rosemount 3051CFP Integral Orifice Flowmeter

Rosemount 3051CFP Integral Orifice Flowmeter December 2013 Rosemount 3051 Rosemount 3051CFP Integral Orifice Flowmeter See Specifications on page 47 and options for more details on each configuration. Rosemount 3051CFP Integral Orifice Flowmeters

More information

Rosemount 3100 Series Ultrasonic Level Transmitters

Rosemount 3100 Series Ultrasonic Level Transmitters Product Data Sheet Ultrasonic Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for on-site programming Continuous measurement of level or distance-to-surface.

More information

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 2088 Absolute and Gage Pressure Transmitter Product Data Sheet February 2015 00813-0100-4690, Rev PB Rosemount 2088 Absolute and Gage Pressure Transmitter Performance of 0.065% with High Accuracy option Lightweight, compact design for cost-effective

More information

Rosemount 3051CFC Compact Flowmeter

Rosemount 3051CFC Compact Flowmeter CFC Compact Flowmeter CFC Compact Flowmeters provide a quick, reliable installation between existing raised face flanges. Depending on your application needs, you can reduce energy loss with the Compact

More information

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description

More information

Rosemount 3051SFP Proplate Flowmeter

Rosemount 3051SFP Proplate Flowmeter SPECIFICATIONS Rosemount 3051SFP Proplate Flowmeter Performance System Reference Accuracy Percentage (%) of volumetric flow rate (1) Beta ( ) (2) Repeatability ±0.1% Line Sizes 1 /2-in. (15 mm) 1-in. (25

More information

Rosemount 3051SFC Compact Orifice Flowmeter

Rosemount 3051SFC Compact Orifice Flowmeter Rosemount Compact Orifice Product Data Sheet Rosemount 3051SFC Compact Orifice Flowmeter SPECIFICATIONS Performance System Reference Accuracy Percent (%) of volumetric flow rate TABLE 1. 3051SFC Compact

More information

Rosemount 3051P In-Line Pressure Transmitter. Product Data Sheet August , Rev BA

Rosemount 3051P In-Line Pressure Transmitter. Product Data Sheet August , Rev BA Rosemount 3051P In-Line Pressure Transmitter Product Data Sheet August 2018 00813-0100-4680, Rev BA August 2018 Settings the standard for pressure measurement Proven best-in-class performance and safety

More information

Rosemount 2051T In-line Pressure Transmitter

Rosemount 2051T In-line Pressure Transmitter February 2017 T In-line Pressure Transmitter T In-line Wireless Pressure Transmitter Configuration 4 20 ma HART with Selectable HART (1) Lower Power with Selectable HART (1) FOUNDATION Fieldbus PROFIBUS

More information

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents Product Data Sheet Intrinsically Safe design enables ability to perform routine maintenance in hazardous areas Predictable life specified under installed conditions Robust design for use in harsh environments

More information

ST 3000 Smart Transmitter Series 900 Extension Models. Specification and Model Selection Guide. Introduction 34-ST /04

ST 3000 Smart Transmitter Series 900 Extension Models. Specification and Model Selection Guide. Introduction 34-ST /04 ST 3000 Smart Transmitter Series 900 Extension Models STD904 Differential 0 to 400 inh 2 O 0 to 1,000 mbar STG90L Gauge 0 to 500 psi 0 to 35 bar Introduction 34-ST-03-74 7/04 Specification and Model Selection

More information

Configuration Data Sheet

Configuration Data Sheet Product Data Sheet Configuration Data Sheet HART / 4 20 ma / AND SAFETY CERTIFIED TRANSMITTER = Default Configuration Customer Information Customer P.O. No. Sensor Model No. Line Item Sensor Type Sensor

More information

Rosemount 3144P Rosemount 3144P Temperature Transmitter

Rosemount 3144P Rosemount 3144P Temperature Transmitter Temperature Transmitter Sensor Drift Alert and Hot Backup features improve measurement reliability while the Transmitter-Sensor Matching feature improves temperature measurement accuracy Statistical Process

More information

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014 Rosemount Pipe Clamp Sensor Reference Manual Reference Manual Title Page The Rosemount 0085 Pipe Clamp Sensor NOTICE Read this manual before working with the product. For personal and system safety, and

More information

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology Data Sheet Brooks Model MT 3810 Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology GENERAL FEATURES Broad range of flow capacities 5% Full scale accuracy

More information

Rosemount 3051 Pressure Transmitter

Rosemount 3051 Pressure Transmitter Rosemount 3051 Pressure Transmitter Product Data Sheet April 2014 00813-0100-4001, Rev RC With the Rosemount 3051 Pressure Transmitter, you ll gain more control over your plant. You ll be able to reduce

More information

Rosemount 2100 Series

Rosemount 2100 Series Rosemount 2100 Series Vibrating Fork Liquid Level Switches Level switches for demanding applications Reliable performance... Rosemount 2100 series vibrating fork level switches are suitable for virtually

More information

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016 Rosemount 0085 Pipe Clamp Sensor Assembly 00825-0100-4952, Rev CA NOTICE This guide provides basic guidelines for Rosemount 0085 Pipe Clamp Sensor. It does not provide instructions for configuration, diagnostics,

More information

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 Introduction Honeywell s STT 3000 family of microprocessor based transmitters covers the full

More information

Electronic Pressure Digest. Pressure and Temperature Transmitters

Electronic Pressure Digest. Pressure and Temperature Transmitters Electronic Pressure Digest Electronic Pressure Digest Pressure and Temperature Transmitters R General Purpose Pressure Transmitters Standard Industrial S-10 These rugged pressure transmitters are designed

More information

Rosemount 248 Temperature Transmitter

Rosemount 248 Temperature Transmitter Product Data Sheet November 2013 00813-0100-4825, Rev KA Rosemount 248 Temperature Transmitter Basic temperature transmitter offers a reliable solution for temperature monitoring points transmitter design

More information

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013 Rosemount 248 Temperature Transmitter 00825-0100-4825, Rev. EA NOTICE This installation guide provides basic guidelines for the Rosemount 248 Wireless. It does not provide instructions for detailed configuration,

More information

High Pressure Conductivity Monitor

High Pressure Conductivity Monitor Product Data Sheet PDS 71-EDS880/1/rev.A August 2006 Model EDS880/1 High Pressure Conductivity Monitor COMPLETE SYSTEM FOR THE DETERMINATION OF CONDUCTIVITY IN HIGH PRESSURE SYSTEMS SENSOR INSTALLS DIRECTLY

More information

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Brooks MT3600 Series Metal Tube Variable Area Flowmeters Data Sheet Flanged, NPT or socket-welded connections 10% full scale accuracy Disassembly for cleaning without removal from the process line Standard direct reading, detachable scales Permanent magnetic

More information

FAHM Co. Temperature Transmitter PTT74 Series

FAHM Co. Temperature Transmitter PTT74 Series FAHM Co. PTT74 Series The PTT74 is a versatile temperature transmitter that delivers field reliability and advanced accuracy and stability to meet demanding process needs. PTT74 Family of Transmitters

More information

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters Product Data Sheet Non-contacting measurement with no moving parts Fast and simple to install and configure Continuous measurement of level, contents (volume), or open channel flow MCERTS certified version

More information

Ar-Mite TM Low Flow Armored Flowmeter

Ar-Mite TM Low Flow Armored Flowmeter Data Sheet Brooks Ar-Mite TM MT 3750C Ar-Mite TM Low Flow Armored Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm

More information

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012 Start Step 1: Physical Installation Step 2: Verify Operation Disposal/Recycling of Depleted Power Modules Product Certifications EC Declaration of Conformity End 00825-0100-4701[ 2012 Rosemount Inc. All

More information

J. Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter with HART Protocol.

J. Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter with HART Protocol. Quick Installation Guide Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter with HART Protocol Rosemount 3051S Start Step 1: Mount the Transmitter Step 2: Consider Housing

More information

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016 Rosemount 148 Temperature Transmitter 00825-0100-4148, Rev GA NOTICE This guide provides basic guidelines for the Rosemount 148. It does not provide instructions for detailed configuration, diagnostics,

More information

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Rosemount 752 FOUNDATION Fieldbus Remote Indicator Rosemount 752 FOUNDATION Fieldbus Remote Indicator Product Data Sheet 00813-0100-4377, Rev FA Two-wire segment powered device Displays up to eight values Link Master Capability Optional PID, Characterizer,

More information

Rosemount 702 Wireless Discrete Transmitter

Rosemount 702 Wireless Discrete Transmitter August 2009 Rosemount 702 Rosemount 702 Wireless Discrete Transmitter Start Step 1: Physical Installation Step 2: Verify Operation Step 3: Reference Information Product Certifications EC Declaration of

More information

Sensall Sapphire. Thermo MeasureTech ULTRASONIC POINT LEVEL SYSTEM

Sensall Sapphire. Thermo MeasureTech ULTRASONIC POINT LEVEL SYSTEM ULTRASONIC POINT LEVEL SYSTEM Introduction Compliance with growing government regulations mandates tighter level controls with advanced diagnostics to avoid releases, overspills and costly environmental

More information

Rosemount 3051S Series of Instrumentation

Rosemount 3051S Series of Instrumentation Product Data Sheet October 2017 00813-0100-4801, Rev UG Rosemount 3051S Series of Instrumentation Scalable pressure, flow, and level solutions Innovation reaching across your operation With the Rosemount

More information

Rosemount 3051CF DP Flowmeters

Rosemount 3051CF DP Flowmeters Product Data Sheet June 2013 00813-0300-4485, Rev EC Rosemount 3051CF DP Flowmeters Up to 1.80% volumetric flow accuracy at 8:1 turndown Available with HART, FOUNDATION fieldbus, and Profibus Protocols

More information

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev. STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.1 Introduction Honeywell s STT 3000 family of microprocessor based smart

More information

Rosemount 3051S Series of Instrumentation

Rosemount 3051S Series of Instrumentation Product Data Sheet January 2016 00813-0100-4801, Rev UA Rosemount 3051S Series of Instrumentation Scalable pressure, flow, and level solutions Innovation reaching across your operation With the Rosemount

More information

Rosemount 3144P Temperature Transmitter

Rosemount 3144P Temperature Transmitter Temperature Transmitter Sensor Drift Alert and Hot Backup features improve measurement reliability while the Transmitter-Sensor Matching feature improves temperature measurement accuracy Statistical Process

More information

Rosemount 3051S MultiVariable Transmitter

Rosemount 3051S MultiVariable Transmitter HART Reference Card HART Rosemount 3051SMV Rosemount 3051S MultiVariable Transmitter A check ( ) indicates the basic configuration parameters. At minimum, these parameters should be verified as part of

More information

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Electronics based on Smart Meter Manager TM Technology

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Electronics based on Smart Meter Manager TM Technology Data Sheet Models MT 3809 & 3819 Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Electronics based on Smart Meter Manager TM Technology Broad range of flow capacities 2%

More information

Rosemount 2120 Vibrating Fork Liquid Level Switch

Rosemount 2120 Vibrating Fork Liquid Level Switch Rosemount 2120 Rosemount 2120 Vibrating Fork Liquid Level Switch Function virtually unaffected by flow, bubbles, turbulence, foam, vibration, solids content, coating, properties of the liquid, and product

More information

Rosemount 4600 Oil & Gas Panel Pressure Transmitter. Quick Start Guide , Rev GA September 2017

Rosemount 4600 Oil & Gas Panel Pressure Transmitter. Quick Start Guide , Rev GA September 2017 Rosemount 4600 Oil & Gas Panel Pressure Transmitter 00825-0100-4022, Rev GA NOTICE NOTICE This guide provides basic guidelines for the Rosemount 4600 Oil & Gas Panel Pressure Transmitter. It does not provide

More information

Rosemount 3051 Pressure Transmitter

Rosemount 3051 Pressure Transmitter Rosemount 3051 Pressure Transmitter Product Data Sheet September 2014 00813-0100-4001, Rev SA With the Rosemount 3051 Pressure Transmitter, you ll gain more control over your plant. You ll be able to reduce

More information

Rosemount 3490 Series

Rosemount 3490 Series Product Data Sheet July 2014 00813-0100-4841, Rev DA Rosemount 3490 Series 4 20 ma + HART Compatible Controller Field mounted controller with integral multi-function LCD and keypad Tough weatherproof wall

More information

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

SmartPower Solutions. Quick Start Guide , Rev CA March 2015 SmartPower Solutions 00825-0100-4701, Rev CA NOTICE This guide provides basic guidelines for the SmartPower family of products. It does not provide instructions for detailed configuration, diagnostics,

More information

Rosemount 8800D Series Vortex Flowmeter

Rosemount 8800D Series Vortex Flowmeter Quick Installation Guide Rosemount 8800D Rosemount 8800D Series Vortex Flowmeter Start Step 1: Mount the Flowmeter Step 2: Consider Housing Rotation Step 3: Set Jumpers and Switches Step 4: Connect Wiring

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70000097 Project: 70125347 Issued to: Thermo Engineering S.r.l Via Giuseppina, 19 26030 Malagnino (CR) Italy Attention: Mr. BOZZETTI The products listed below are

More information

Ultrasonic Point Level Switches

Ultrasonic Point Level Switches see more at SORInc.com Request Quote Ultrasonic Point Level Switches Ultrasonic point level switches are a cost-effective solution for your applications. Installation requires mounting the sensor (threaded

More information

Rosemount 2051CF DP Flowmeters

Rosemount 2051CF DP Flowmeters Product Data Sheet June 2013 00813-0400-4485, Rev EC Rosemount 2051CF DP Flowmeters Up to 2.00% volumetric flow accuracy at 5:1 turndown Available with HART and FOUNDATION fieldbus Protocols 2-year stability

More information

Rosemount 644H and 644R Smart Temperature Transmitters

Rosemount 644H and 644R Smart Temperature Transmitters Quick Installation Guide March 2011 Rosemount 644 Rosemount 644H and 644R Smart Temperature Transmitters Start Step 1: Configure (Bench Calibration) Step 2: Verify Configuration Step 3: Set the Switches

More information

Rosemount 3144P Temperature Transmitter

Rosemount 3144P Temperature Transmitter Temperature Transmitter Sensor Drift Alert and Hot Backup features improve measurement reliability while the Transmitter-Sensor Matching feature improves temperature measurement accuracy. Communicates

More information

Rosemount 644 Temperature Transmitter

Rosemount 644 Temperature Transmitter Product Data Sheet September 2018 00813-0100-4728, Rev UD Rosemount 644 Temperature Transmitter The most versatile temperature transmitter Reduce complexity and simplify the day-to-day operations of your

More information

Sapphire ULTRASONIC POINT LEVEL SYSTEM

Sapphire ULTRASONIC POINT LEVEL SYSTEM ULTRASONIC POINT LEVEL SYSTEM Introduction Compliance with growing government regulations mandates tighter level controls with advanced diagnostics to avoid releases, overspills and costly environmental

More information

Rosemount 148 Temperature Transmitter. Reference Manual , Rev CA April 2014

Rosemount 148 Temperature Transmitter. Reference Manual , Rev CA April 2014 Rosemount 148 Temperature Transmitter Reference Manual Reference Manual Rosemount 148 Temperature Transmitter Rosemount 148 Hardware Revision 5 NOTICE Read this manual before working with the product.

More information

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74 AM54 Instruction Bulletin North American Installation Addendum Document Number PN25016 Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

More information

Rosemount 2051 Pressure Transmitter

Rosemount 2051 Pressure Transmitter Rosemount 2051 Pressure Transmitter Product Data Sheet April 2013 00813-0100-4101, Rev JA Coplanar platform enables integration of primary elements, manifolds, and remote seal solutions Best in Class performance

More information

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

MSM400 Ultrasonic Suspended Solids Monitoring and Control System Product Data Sheet MSM400 Ultrasonic Suspended Solids Monitoring and Control System Continuous sludge discharge monitor for up to 50% suspended solid The MSM400 system contains a control unit and either

More information

Enraf Servo Gauge 854 XTG

Enraf Servo Gauge 854 XTG Enraf Servo Gauge 854 XTG Cut costs, not repeatability. Honeywell s 854 XTG servo gauge is a high performance alternative to other tank level measurement technologies such as radar tank level gauges. It

More information

Druck DPI 705/DPI 705 IS Series

Druck DPI 705/DPI 705 IS Series GE Sensing & Inspection Technologies 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Druck DPI 705/DPI 705 IS Series Digital Pressure

More information

Rosemount 3051 Pressure Transmitter

Rosemount 3051 Pressure Transmitter Rosemount 3051 Pressure Transmitter Product Data Sheet December 2017 00813-0100-4001, Rev TB With the Rosemount 3051 Pressure Transmitter, you ll gain more control over your plant. You ll be able to reduce

More information

Rosemount 3144P Rosemount 3144P Temperature Transmitter

Rosemount 3144P Rosemount 3144P Temperature Transmitter Product Data Sheet Rosemount 3144P Rosemount 3144P Temperature Transmitter Industry-leading temperature transmitter delivers unmatched field reliability and innovative process measurement solutions Achieve

More information

Enraf Servo Gauge 854 ATG

Enraf Servo Gauge 854 ATG Enraf Servo Gauge 854 ATG Setting the standard in gauging. From the company that pioneered development of modern tank gauges, Honeywell s 854 Automatic Tank Gauge has become an industry standard all over

More information

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Polytron 8200 CAT Detection of flammable gases and vapors Dräger Polytron 8200 CAT Detection of flammable gases and vapors The Dräger Polytron 8200 CAT is an advanced explosion proof transmitter for the detection of flammable gases in the lower explosion limit

More information

Ultrasonic Switches. Features & Benefits

Ultrasonic Switches. Features & Benefits Why use an ultrasonic switch over other level technologies? Depending upon your application, there may be three or four technologies equally suited for your application; however; only one will be the best

More information

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion

More information

Rosemount 2120 Vibrating Fork Liquid Level Switch

Rosemount 2120 Vibrating Fork Liquid Level Switch Product Data Sheet Rosemount 2120 Rosemount 2120 Vibrating Fork Liquid Level Switch Function virtually unaffected by flow, bubbles, turbulence, foam, vibration, solids content, coating, properties of the

More information

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma, User s Manual YTA Series Temperature Transmitters [Style: S3] Manual Change No. 10-008 Please use the attached sheets in the following manuals when the product is with /KU2 option and EN60000 Series based

More information

Rosemount 2051 Pressure Transmitter

Rosemount 2051 Pressure Transmitter Rosemount 2051 Pressure Transmitter Product Data Sheet May 2016 00813-0100-4101, Rev KB Rosemount Coplanar platform enables integration of primary elements, manifolds, and remote seal solutions Best in

More information

Instrumentation and Controls Group

Instrumentation and Controls Group Instrumentation and Controls Group Jerguson Gage and Valve is the leading supplier of level gaging products, offering the world s largest selection of liquid level gage glasses, magnetic gages, and accessories.

More information

Glass Tube Variable Area Flowmeter

Glass Tube Variable Area Flowmeter GT 1000 Series Models 1020, 1024, 1026, 1027 Design Specifications DS-GT 1000 April, 1997 (Supersedes issue dated December, 1996) Glass Tube Variable Area Flowmeter Wide choice of application-specific

More information

Rosemount 2088, 2090F, and 2090P Pressure Transmitter

Rosemount 2088, 2090F, and 2090P Pressure Transmitter Quick Start Guide 00825-0100-4108, Rev BA Rosemount 2088, 2090F, and 2090P Pressure Transmitter with 4-20 ma HART and 1-5 Vdc Low Power HART Protocol (Revision 5 and 7) Quick Start Guide NOTICE This guide

More information

Rosemount 3051S MultiVariable Extension Supplement

Rosemount 3051S MultiVariable Extension Supplement Product Data Sheet April 2015 00813-0400-4801, Rev AA Rosemount 3051S MultiVariable Extension Supplement With the Rosemount 3051S MultiVariable Extensions, you can gain valuable process insight with two

More information

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

Rosemount 2088, 2090P, and 2090F Pressure Transmitters Quick Start Guide 00825-0100-4690, Rev FD Rosemount 2088, 2090P, and 2090F Pressure Transmitters with 4 20 ma HART and 1 5 Vdc HART Low Power Protocol Quick Start Guide NOTICE This installation guide provides

More information

MT3750C Series. Metal Tube Variable Area Flowmeters. Ships in 5 days. Overview. Product Description. Features. Variable Area

MT3750C Series. Metal Tube Variable Area Flowmeters. Ships in 5 days. Overview. Product Description. Features. Variable Area DS-VA-MT3750C-eng September, 2017 Data Sheet MT3750C Series MT3750C Series Ships in 5 days Overview Variable Area Metal Tube Variable Area Flowmeters Brooks MT3750 meter operation is based on the variable

More information