2 WHAT TO EXPECT DURING A FIRE DOOR INSPECTION

3 Basic Fire Door Inspections 1. Fire door basic function 2. Understanding codes 3. Responsibility of end user 4. Common fire door deficiencies 5. What your door inspector should know 6. Different types of reports 7. Repairs

4 Why is PFP/Barrier Management Important? It s part of the overall fire protection plan. Active Fire Protection VS. Passive Fire Protection

5 What Makes Up Passive Fire Protection? Dampers Doors Fire Resistant Rated Barriers (i.e. Fire Wall)

6 3 Principles Of Fire Door Protection Help prevent spread of smoke and flames Compartmentalize a building Allow for safe escape

7

8

9

10 What Does a Certified Fire Door Inspection Accomplish? Confirms fire doors are properly installed and maintained Increases safety of building and occupants Limits liability to end user Helps end user avoid fines Follow CMS regulations

11 INTRO Fire Door Inspection Regulations Have Changed Flier Sent to Hospitals and Assisted Living CMS has adopted the 2012 edition of the NFPA Life Safety Code. ARE YOUR FIRE DOORS COMPLIANT? Significant impact on the steps to compliance for Fire Doors The newest standard requires: Fire-rated doors to be tested for functionality no less than annually Inspections to be performed by a qualified person A written record of the inspection be kept on file for the AHJ

12 Fire Door Regulations NFPA 80 Standard for Fire Fire Doors and other opening protectants not inspected less than annually New construction should have additional test Fire door inspections should be a part of annual preventative maintenance plan Building owners and property managers are responsible for having door inspections done by trained and educated inspectors

13 INTRO Common Deficiencies Found During Inspections Painted or missing fire door labels

14 INTRO Common Deficiencies Found During Inspections Improper gaps between two doors Improper gaps between door and door frame

15 Common Deficiencies Found During Inspections Kicked down door holder or door stop

16 INTRO Common Deficiencies Found During Inspections Hardware items that are attached to door that are not rated for door

17 INTRO Common Deficiencies Found During Inspections Holes left by deleted items

18 INTRO Common Deficiencies Found During Inspections Fire doors blocked or made to stay in open position Items placed around fire door so it cannot open fully

19 INTRO Common Deficiencies Found During Inspections Broken, defective or missing hardware pieces

20 INTRO Common Deficiencies Found During Inspections Locking devices not self latching Latching bolt cannot be retracted

21 INTRO Common Deficiencies Found During Inspections Fire doors must be self closing ** If coordinator is used, inactive lead closes before active lead

22 INTRO Common Deficiencies Found During Inspections Missing or incorrect fasteners

23 INTRO Common Deficiencies Found During Inspections Bottom flush bolts do not project ½ into strike Bottom flush bolts must engage properly

24 What Is A Fire Door? Applicable Codes: NFPA 80 and 105 *90-95% fire doors are noncompliant

25 Qualified Technicians and Inspectors Knowledgeable Experience with fire door product application Experience with fire door installation Expertise with swinging doors Familiar with different types of hardware Work with hollow metal doors and frames Work with wood fire doors

26 Qualified Technicians and Inspectors IQP (Intertek), IFDIA (International Fire Door Inspection Association) or equivalent certifications held by trainers of qualified technicians. * Series of courses and 4 hour exam Thorough knowledge of fire and building codes * NFPA 80 * NFPA 101 Industry Experience Security Integration Architectural Services Project Management

27 What to Expect During Fire Door Inspections Technician and representative to meet with owner/ property manager/ end user prior to inspection Review building plans and or property Pick which type of report best fits needs Each opening evaluated *Frame *Hinges *Bolts *Locks *Exit hardware *Check for proper functionality and compliance

28 Fire Door - Points of Inspection The National Fire Protection Association (NFPA) requires annual fire door inspections with a written record of the inspection. NFPA 80, Section : states that, as a minimum, the following items must be verified: No open holes or breaks exist in surfaces of either the door or frame. Glazing, vision light frames & glazing beads are intact and securely fastened in place, if so equipped. The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. No parts are missing or broken. Door clearances at the door edge of the door frame, on the pull side of the door, do not exceed clearances listed in (the clearance under the bottom of the door shall be a maximum of 3/4 ) and (top & edges 1/8 ). The self-closing device is operational; that is, the active door completely closes when operated from the full open position. If a coordinator is installed, the inactive leaf closes before the active leaf. Latching hardware operates and secures the door when it is in the closed position. Auxiliary hardware items that interfere or prohibit operation are not installed on the door or frame. No field modifications to the door assembly have been performed that void the label. Gasketing and edge seals, where required, are inspected to verify their presence and integrity.

29 Types of Fire Door Inspection Reports Simple field inspection report * For each opening * Usually an existing template

30 Types of Fire Door Inspection Reports Standard Inspection Report * Per Opening Report * Summary of deficiencies * Corrective action report

31 Types of Fire Door Inspection Reports Custom Reports * Per Opening Report * Summary of deficiencies * Corrective action report * Designed to what end user wants * Contains items specific to each opening * Part # s * Specific Model # s * Pictures of each opening and pictures of deficiencies * Plotting/ CAD drawings of each door

32 Types of Fire Door Inspection Reports Custom to end user software *Door opening statistics go directly into maintenance software *Reports and punch lists generated by end user

33 Expectations of Return Trip Re- inspection of non-compliant openings Confirm repairs Work with end user on program to make sure doors stay compliant Make sure doors are properly installed and designed

34 Review Importance of fire door inspections Top deficiencies of fire doors Fire door inspection process Expectations of inspections Different types of reports Re-inspections

35 Questions? Questions regarding barrier protection? Contact: Heidi Young LSS Life Safety Services Western Regional Manager (502)

Developing a Healthcare Facility Fire Door Inspection Program

Developing a Healthcare Facility Fire Door Inspection Program Developing a Healthcare Facility Fire Door Inspection Program WELCOME Moderator: Richard Schieferdecker support.webinato.com Audio QUESTIONS How To Ask a Question: 1 POLLING There will be occasional interactive

More information

Swinging Egress and Fire Doors

Swinging Egress and Fire Doors Presented by: AHCA Seminar: Inspecting and Maintaining Swinging Egress and Fire Doors Current State CMS Memorandum July 28, 2017 Tuesday May, 3, 2016 CMS issued the final rule adopting the 2012 Life Safety

More information

2012 Life Safety and Health Care Facility Codes - Door Inspections and Other Critical Inspection, Testing and Maintenance

2012 Life Safety and Health Care Facility Codes - Door Inspections and Other Critical Inspection, Testing and Maintenance 2012 Life Safety and Health Care Facility Codes - Door Inspections and Other Critical Inspection, Testing and Maintenance Will begin at 1 pm Housekeeping Announcements Problems during the call? Press *0

More information

Hands On Training for Fire Door Products and Fire Door Assemblies

Hands On Training for Fire Door Products and Fire Door Assemblies 2017 NFPA Conference & Expo Hands On Training for Fire Door Products and Fire Door Assemblies Presented by: Paul M. Goldense, FDAI Goldense Building Products, Inc. Jeffery S. Batick, FDAI Allegion Why

More information

Design, Installation, Inspection, and Maintenance

Design, Installation, Inspection, and Maintenance Presents: Swinging Fire Door Assemblies with Builders Hardware Design, Installation, Inspection, and Maintenance About the Instructor & Presenter: Paul Baillargeon, AHC, FDAI A 40 year veteran in the Door

More information

Page 1 of 31 Second Revision No. 1-NFPA 80-2014 [ Section No. 2.3.2 ] 2.3.2 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM A36/A36M,

More information

Committee Input No. 1-NFPA [ Chapter 2 ]

Committee Input No. 1-NFPA [ Chapter 2 ] of 35 11/4/2016 6:18 PM Committee Input No. 1-NFPA 80-2016 [ Chapter 2 ] The committee will review and update the editions of the referenced publications to the correct edition at the Second Draft meeting.

More information

WIND TURBINE DAMAGE PREVENTION

WIND TURBINE DAMAGE PREVENTION WIND TURBINE DAMAGE PREVENTION SAFETY GUIDELINE 2017 1 Wind turbine damage prevention Index 1 PURPOSE... 2 2 GENERAL... 2 2.1 Technical implementation and type approval... 2 2.2 Transportation... 2 2.3

More information

FLUSHBOLT - WITHOUT ASTRAGAL (Example: Wide Inactive Leaf) DOOR HARDWARE PREPARATIONS

FLUSHBOLT - WITHOUT ASTRAGAL (Example: Wide Inactive Leaf) DOOR HARDWARE PREPARATIONS FLUSHBOLT - WITHOUT ASTRAGAL (Example: Wide Inactive Leaf) Preparation for flushbolts and strikes in inactive leaves (See Note 3) 6-3/4 9 (See Note 2) 1 Flushbolt Elevation Detail Flushbolt Prep Detail

More information

THE UNIVERSITY OF THE WEST INDIES Mona Campus Human Resource Management Division (HRMD) SECTION I GENERAL SAFETY

THE UNIVERSITY OF THE WEST INDIES Mona Campus Human Resource Management Division (HRMD) SECTION I GENERAL SAFETY EOHS 01-004 Office and Classroom Safety Introduction Though offices and classrooms are thought of as relatively safe working environments, they can present potential risks that are often overlooked. Blocked

More information

Regulatory Reform (Fire Safety) Order 2005

Regulatory Reform (Fire Safety) Order 2005 Regulatory Reform (Fire Safety) Order 2005 This document has been prepared by ASDMA (Architectural & Specialist Door Manufacturers Association) to provide for guidance for Responsible Persons in respect

More information

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT FIRE SAFETY INSPECTION REPORT AMITY DESIGNS LTD. HOUSE#7&9, ROAD#9 BLOCK D, SECTION #11MIRPUR DHAKA OTHER FACTORIES: NONE April 21, 2014 Page 2 SUMMARY was surveyed for fire safety on 4/21/2014 by Hughes

More information

Top (15) Life Safety Code Deficiencies and Tips for Compliance (10/01/2011 thru 02/22/2012)

Top (15) Life Safety Code Deficiencies and Tips for Compliance (10/01/2011 thru 02/22/2012) 1. K62 Automatic Sprinkler Systems - Automatic sprinkler systems are continuously maintained in reliable operating condition and are inspected and tested periodically. 18.7.6, 19.7.6, 4.6.12, NFPA 13,

More information

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216) Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216) Optional Network Module x3 #8-32 x 5/16" Machine screws x4 #7 wood & #8-32 machine x 20mm Combination

More information

ABLOY FIRE DOOR CLOSING SYSTEMS

ABLOY FIRE DOOR CLOSING SYSTEMS FIRE DOOR CLOSING SYSTEMS Maximum security An ASSA ABLOY Group brand FIREDOOR CLOSING SYSTEMS Maximum security and easy access ABLOY high security products are well known and highly respected all over

More information

2016 Joint Commission Update

2016 Joint Commission Update 2016 Joint Commission Update Bert M. Gumeringer, MBA, CHFM, FASHE Asst. Vice President-Facilities Operations Texas Children s Hospital August 12, 2016 11:30am-12:30pm Top 10 Findings Comparison-2015 vs.2016

More information

Measures (ILSM) Process

Measures (ILSM) Process Managing the Interim Life Safety Measures (ILSM) Process 1 A Program for The Texas Association of Healthcare Facility Management Monday, April 30, 2012 Robert H. Bartels, CHFM CHSP CHEP SASHE President,

More information

Panic & emergency exit devices

Panic & emergency exit devices CFPA-E Guideline No 2:2007 Panic & emergency exit devices FORWORD The European fire protection associations have decided to produce common guidelines in order to achieve similar interpretation in the European

More information

EcoAisle Thermal Containment System

EcoAisle Thermal Containment System Guide Specifications EcoAisle Thermal Containment System THIS GUIDE SPECIFICATION IS WRITTEN IN ACCORDANCE WITH THE CONSTRUCTION SPECIFICATIONS INSTITUTE (CSI) MASTERFORMAT. THIS SECTION MUST BE CAREFULLY

More information

INSPECTOR I SKILLS ADMINISTRATION

INSPECTOR I SKILLS ADMINISTRATION INSPECTOR I SKILLS ADMINISTRATION 1- Prepare inspection reports so that the report is clear and concise and reflects the findings of the inspection in accordance with the applicable codes and standards..

More information

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH) Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH) The following represents a review of the Life Safety chapter of the new 2018 Joint Commission CAMH manual for

More information

Basic Fire Door Requirements

Basic Fire Door Requirements TECHNICAL DATA SERIES S D I 118-05 Basic Fire Door Requirements 2009 Steel Door Institute STEEL DOOR INSTITUTE 30200 DETROIT ROAD CLEVELAND, OHIO 44145 Technical Data Series SDI 118-2005 Basic Fire Door

More information

2. Interior doors shall be not less than 18 gauge steel.

2. Interior doors shall be not less than 18 gauge steel. DIVISION 8 - DOORS AND WINDOWS 08100 METAL DOORS AND FRAMES 1. Exterior doors shall be not less than 16 gauge steel. The top channel of each metal door shall be solid without pockets which collect dirt

More information

Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards

Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization Life Safety The primary goal of fire safety

More information

IntelliDoX Operator Manual

IntelliDoX Operator Manual IntelliDoX Operator Manual OPERATOR MANUAL TABLE OF CONTENTS Table of Contents Table of Contents...1 About this Publication...3 Important Safety Information: Read First...4 Getting Started...5 About the

More information

Life Safety - Means of Egress/Exits NFPA 101

Life Safety - Means of Egress/Exits NFPA 101 Life Safety - Means of Egress/Exits NFPA 101 Properly designed exits provide a safe path of escape from a fire or other emergency environment. The means of egress (exits) should be arranged to permit all

More information

Nest x Yale Lock Installation and Programming Guide. Back button Check (Set / Continue) Keypad

Nest x Yale Lock Installation and Programming Guide. Back button Check (Set / Continue) Keypad Nest x Yale Lock Installation and Programming Guide Warning Status Indicator Settings Speaker Back button Check (Set / Continue) Low Battery Indicator Keypad Failsafe 9 volt Battery Connection (Use Alkaline

More information

HEAT & SMOKE VENT INSPECTION AND MAINTENANCE PACKET

HEAT & SMOKE VENT INSPECTION AND MAINTENANCE PACKET HEAT & SMOKE VENT INSPECTION AND MAINTENANCE PACKET Fire protection for your warehouse and industrial properties. Shedding light on the importance of proper routine inspection and maintenance of your heat

More information

Schueco Fire and Smoke Protection Systems

Schueco Fire and Smoke Protection Systems Schueco Fire and Smoke Protection Systems Green Technology for the Blue Planet Clean Energy from Solar and Windows 02 Schueco Fire and Smoke Protection Systems Fire and Smoke Protection Systems Schueco

More information

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS Introduction When properly installed and maintained, automatic fire sprinkler systems have proven to be the most effective means for protecting life and

More information

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200 INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200 Installer: Owner: READ AND SAVE THESE INSTRUCTIONS Please leave Installation Instructions with the range hood. Please keep Installation

More information

An ASSA ABLOY Group brand Series. Architectural Door Closers

An ASSA ABLOY Group brand Series. Architectural Door Closers An ASSA ABLOY Group brand 2700 Series Architectural Door Closers introduction Yale 2700 series architectural door closers are ideal for commercial applications where ease of use, installation and aesthetics

More information

Secondary Suites. Guidelines for the construction of Accessory Secondary Suites in the City of Abbotsford August

Secondary Suites. Guidelines for the construction of Accessory Secondary Suites in the City of Abbotsford August Secondary Suites Guidelines for the construction of Accessory Secondary Suites in the City of Abbotsford August 2015 PLANNING & DEVELOPMENT SERVICES Building Permits & Licences 1st Floor, 32315 South Fraser

More information

Passive Fire Protection Guidance. Niall Rowan Technical Officer Association for Specialist Fire Protection

Passive Fire Protection Guidance. Niall Rowan Technical Officer Association for Specialist Fire Protection Passive Fire Protection Guidance for the Fire Risk Assessor Niall Rowan Technical Officer Association for Specialist Fire Protection ASFP has just completed a guide on what to look for when undertaking

More information

Instructions. Duct Mount Accessory Q Rev: 11/

Instructions. Duct Mount Accessory Q Rev: 11/ Instructions Duct Mount Accessory Q5016 Rev: 11/16 95-8752 Table of Contents DESCRIPTION...1 FEATURES...1 OPERATION...1 SPECIFICATIONS.... 2 INSTALLATION... 2 Detector Location...2 Tools for Assembly...4

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 92 ST - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Type Memo Tag These guidelines are meant solely to provide guidance to surveyors in the survey process. ST - K0100 - General Requirements

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FACTORY BUILT CHIMNEY CONNECTOR A MAJOR CAUSE OF CHIMNEY CONNECTOR RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE

More information

Understanding and Applying NFPA 25

Understanding and Applying NFPA 25 Understanding and Applying NFPA 25 Texas Edition Learning Objectives Describe the scope of NFPA 25. Distinguish between sprinkler system problems that fall within the scope of NFPA 25 and those that do

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 94 ST - K0000 - Initial Comments Title Initial Comments Statute or Rule Type Memo Tag These guidelines are meant solely to provide guidance to surveyors in the survey process. ST - K0100 - General

More information

Fire doors guidance. Provided by

Fire doors guidance. Provided by Fire doors guidance Provided by Contents 1. Scope... 3 2. Introduction... 3 3. Where you could find a fire door... 4 4. Doors not required to be fire doors... 5 5. Which way should a fire door open?...

More information

Why Should You Invest In An Access Management System?

Why Should You Invest In An Access Management System? Why Should You Invest In An Access Management System? The key word in this question is Invest. Buying and installing an access system by itself is an investment that will increase security, enhance overall

More information

Over-the-Range Microwave Oven Installation Instructions MVH130* MVH230* MVH330*

Over-the-Range Microwave Oven Installation Instructions MVH130* MVH230* MVH330* Over-the-Range Microwave Oven Installation Instructions MVH130* MVH230* MVH330* * Additional alphanumeric characters representing other models in the series may follow each model number. Keep these instructions

More information

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME Section No. Subject Page No. 1 Authority and Purpose 10-1 2 Definitions

More information

Market Introduction DORMA. Modular Panic Hardware System PHA 2000 / PHB 3000

Market Introduction DORMA. Modular Panic Hardware System PHA 2000 / PHB 3000 Market Introduction DORMA Modular Panic Hardware System PHA 2000 / PHB 3000 Introduction PH System 1 Introduction European Panic Hardware System PHA 2000 PHB 3000 External trim series PHT 3900 compatible

More information

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT FIRE SAFETY INSPECTION REPORT RAISA FASHIONS LTD. ACCORD ID: 11741 PLOT# B63, BSCIC INDUSTRIAL ESTATE, KANCHPUR, SONORGAON, NARAYANGANJ OTHER FACTORIES: NONE February 27, 2015 Page 2 SUMMARY was surveyed

More information

WEST VIRGINIA UNIVERSITY

WEST VIRGINIA UNIVERSITY WEST VIRGINIA UNIVERSITY Environmental Health and Safety (SOP) WV State Fire Marshal (SFM) Project Plans Review Process & Procedures West Virginia University Environmental Health & Safety Page 1 of 10

More information

LKM7000 Lock Series. Single Motion Egress RIM DEVICES High Security Combination Lock & Access Control Compatible. COMPLIANT

LKM7000 Lock Series. Single Motion Egress RIM DEVICES High Security Combination Lock & Access Control Compatible. COMPLIANT High Security Locking Solutions LKM7000 Lock Series Single Motion Egress RIM DEVICES High Security Combination Lock & Access Control Compatible. COMPLIANT FF-L-2890 ADA/UFSA UL Fire Rated (*90 minute rating

More information

White Papers: Delayed Egress Hardware

White Papers: Delayed Egress Hardware www.sdcsecurity.com service@sdcsecurity.com [t] 800.413.8783 805.494.0622 [f] 805.494.8681 801 Avenida Acaso, C ox 3670, Camarillo CA 93011-3670 www.sdcsecurity.com White Papers: Delayed Egress Hardware

More information

PHA Panic Hardware for timber doors

PHA Panic Hardware for timber doors PHA 2500 Panic Hardware for timber doors DORMA PHA 2500 Panic Hardware for timber doors The DORMA PHA 2500 Panic Hardware system. PHA 2500 combined with Panic mortice lock for single- and double-leaf doors

More information

5900 Series X-in Low Energy Power Operator

5900 Series X-in Low Energy Power Operator 5900 Series X-in Low Energy Power Operator INTRODUCTION The Norton 5900 Series X-in is a full-featured, extremely quiet, low energy door operator designed for moderate to high traffic doors. This cost-effective

More information

Proven performance for your door system. Ultimate Astragal Family

Proven performance for your door system. Ultimate Astragal Family WHAT DOES PERFORMANCE STANDARD MEAN for YOU? Proven performance for your door system. Ultimate Astragal Family Patented sealing systems prevent air and water infiltration, eliminate deflection and enhance

More information

Safe Operating Procedure

Safe Operating Procedure Safe Operating Procedure (Revised 10/17) HOT WORK PERMIT OPERATIONS Authority In recognition of the inherent hazards posed by certain hot work processes, the National Fire Protection Agency adopted Standard

More information

Replacement of pneumatic actuators on Ruskin negator spring dampers with Belimo FSxx Series

Replacement of pneumatic actuators on Ruskin negator spring dampers with Belimo FSxx Series WARNING! Before replacing actuator, damper must be inspected and determined to be fully functional. See NFPA checklists below. Contents Replacement of pneumatic actuators on Ruskin negator spring dampers

More information

FIRE DOORS RHUL REQUIREMENTS

FIRE DOORS RHUL REQUIREMENTS Fire Safety Technical Guide FIRE DOORS RHUL REQUIREMENTS This guide draws together the general requirements of a range of published standards and reference documents and is to be used in addition to any

More information

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION 087100 - DOOR HARDWARE PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Commercial door hardware. 1.2 SUBMITTALS A. Product Data: For each type of product indicated. B. Other

More information

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN Title/Description: Life Safety & Fire Prevention Management Department: Facilities Management Personnel: All Effective Date: 5/97 Revised: 7/00, 7/01, 7/02, 7/03, 7/04, 7/05, 7/08 LIFE SAFETY & FIRE PREVENTION

More information

Slide 1. Slide 2 Instructor. Slide 3. NFPA 25 The Owner s Manual. Roles & Responsibilities DISCLAIMER

Slide 1. Slide 2 Instructor. Slide 3. NFPA 25 The Owner s Manual. Roles & Responsibilities DISCLAIMER Slide 1 NFPA 25 The Owner s Manual Roles & Responsibilities Presented by: Bob Caputo Slide 2 Instructor Bob is the Executive Vice President of Compliance Solutions with Telgian Corporation. He is the Chairman

More information

JOINT COMMISSION PREPAREDNESS / STATEMENT OF CONDITIONS DRAWINGS WSSHE SOUTHWEST CHAPTER NOVEMBER 19, 2015

JOINT COMMISSION PREPAREDNESS / STATEMENT OF CONDITIONS DRAWINGS WSSHE SOUTHWEST CHAPTER NOVEMBER 19, 2015 JOINT COMMISSION PREPAREDNESS / STATEMENT OF CONDITIONS DRAWINGS WSSHE SOUTHWEST CHAPTER NOVEMBER 19, 2015 AGENDA INTRODUCTION OF PRESENTERS SOC VS. FIRE & LIFE SAFETY DRAWINGS HAZARDOUS AREAS VS. INCIDENTAL

More information

Are You Prepared? The impending impact of Code on Servicing Security Systems

Are You Prepared? The impending impact of Code on Servicing Security Systems Sam Docknevich, PSP, Security Service Portfolio Manager Are You Prepared? The impending impact of Code on Servicing Security Systems Siemens AG 2015 All rights reserved. usa.siemens.com/infrastructure-cities

More information

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal M.S. Montgomery Fire Marshal September 1, 2010 This document describes rules changes affecting the operation and fire safety in foster homes licensed and regulated by the Texas Department of Family and

More information

AUTOMATIC SWINGING DOOR

AUTOMATIC SWINGING DOOR AAADM American Association of Automatic Door Manufacturers AUTOMATIC SWINGING DOOR OWNER'S MANUAL Distributed by: Contents Section Page Caution 2 To Our Customers 2 Service Availability 3 Compliance with

More information

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT FIRE SAFETY INSPECTION REPORT ALAUDDIN GARMENTS LTD. 88, KAZI NAZRUL ISLAM AVENUE, TAJGAON, DHAKA- 1215 OTHER FACTORIES: CAMBRIDGE GARMENTS, PRIMODIAL April 27, 2014 Page 2 SUMMARY was surveyed for fire

More information

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT:

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1136 Reissued 10/2017 This report is subject to renewal 10/2018. DIVISION: 07 00

More information

Installation Instructions

Installation Instructions Installation Instructions Over the Range Microwave Oven BEFORE YOU BEGIN (Read these instructions completely and carefully.) IMPORTANT IMPORTANT Save these instructions for local inspector s use. Observe

More information

Taming the Health Care Building Codes NFPA vs. The International and Chicago Building Codes JENSEN & HALSTEAD LTD.

Taming the Health Care Building Codes NFPA vs. The International and Chicago Building Codes JENSEN & HALSTEAD LTD. Taming the Health Care Building Codes NFPA vs. The International and Chicago Building Codes Comparing the Codes: NFPA 101 Life Safety Code (2000) (NFPA) International Building Code (2012) (IBC) Chicago

More information

Procedure DESCRIPTION/OVERVIEW

Procedure DESCRIPTION/OVERVIEW Applies To: UNMH Responsible Department: Life Safety Revised: 07.08.16 Procedure Patient Age Group: (X ) N/A ( ) All Ages ( ) Newborns ( ) Pediatric ( ) Adult DESCRIPTION/OVERVIEW To assure the safety

More information

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST MUSTANG

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST MUSTANG specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1965-66 MUSTANG CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect

More information

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference 3000 Premier Series Non-Programmable Single Stage /Cool Digital Thermostat OWNERS MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage

More information

Fire Door Maintenance Guide.

Fire Door Maintenance Guide. Fire Door Maintenance Guide http://www.c-sgroup.co.uk/products/acrovyn-impact-resistant-doors/ Introduction Fire Doors are a critical safety feature of any building in which people work or visit, as they

More information

ACT Cartridge Dust Collector

ACT Cartridge Dust Collector IOM-101-1 ACT Cartridge Dust Collector Installation and Operation Manual ACT Dust Collectors CAUTION! Accidents happen, be careful and always follow all local and federal regulations! Fires and explosions

More information

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS SEEKIRK, INC. 2420 Scioto Harper Dr. Columbus, OH 43204 Tel: (614) 278-9200 FAX: (614) 278-9257

More information

Ch. 569 FIRE AND SAFETY SERVICES 28 CHAPTER 569. FIRE AND SAFETY SERVICES GENERAL PROVISIONS INTERNAL DISASTER PLAN EVACUATION DRILLS

Ch. 569 FIRE AND SAFETY SERVICES 28 CHAPTER 569. FIRE AND SAFETY SERVICES GENERAL PROVISIONS INTERNAL DISASTER PLAN EVACUATION DRILLS Ch. 569 FIRE AND SAFETY SERVICES 28 CHAPTER 569. FIRE AND SAFETY SERVICES Sec. 569.1. Principle. 569.2. Fire safety standards. 569.3. Policies and procedures. GENERAL PROVISIONS 569.11. Firefighting service.

More information

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7 WET SPRINKLER Monthly Wet Sprinkler 2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7 VISUALS [per NFPA 25-1998 ed] 1. Gauge (Ck for Condition, Normal Pressure) [per 2-2.4.1] 2. Valves

More information

MINI BLINDS Classic GETTING STARTED STANDARD HARDWARE. A few simple tools are required: OPTIONAL HARDWARE

MINI BLINDS Classic GETTING STARTED STANDARD HARDWARE. A few simple tools are required: OPTIONAL HARDWARE MINI BLINDS Classic GETTING STARTED STANDARD HARDWARE A few simple tools are required: Steel Tape Measure Pencil Level End Brackets (Open Position LH & RH) Top Brackets Power Drill and Drill Bits Flathead

More information

The Technical Committee on Commissioning and Integrated Testing

The Technical Committee on Commissioning and Integrated Testing National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org TO: FROM: The Technical Committee on Commissioning and Integrated Testing

More information

PANIC HARDWARE ACCESSORIES & PARTS

PANIC HARDWARE ACCESSORIES & PARTS PANIC HARDWARE ACCESSORIES & PARTS DX 200 Keepers and strikes PO OSK 3405 Keepers for the vertical bottom latch. Forms a set together with the keeper shown below (PO BSK 3405A) for assembly on a stone

More information

/WON BuyLine 3726 WON-DOOR. FireGuard. The ORIGINAL horizontal sliding accordion fire door.

/WON BuyLine 3726 WON-DOOR. FireGuard. The ORIGINAL horizontal sliding accordion fire door. 08 11 73/WON BuyLine 3726 WON-DOOR FireGuard TM The ORIGINAL horizontal sliding accordion fire door. Fire Safety by Design Founded in 1962, the Won-Door Corporation introduced the world s most durable

More information

The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101):

The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101): The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101): 1.1.1 Title. NFPA 101, Life Safety Code, shall be known as the Life Safety Code, is cited as such, and shall

More information

RELEASE DEVICE CONTROLS

RELEASE DEVICE CONTROLS RELEASE DEVICE CONTROLS RELEASE DEVICE MODEL C+ INSTALLATION MANUAL UL LISTED CANADIAN LISTED CSFM: 7300-48:00 GENERAL DESCRIPTION: MADE IN THE U.S.A. S/N: The LM0-C+ Release Device/Control Panel is a

More information

SECTION OVERHEAD COILING FIRE DOORS

SECTION OVERHEAD COILING FIRE DOORS SECTION 08331 OVERHEAD COILING FIRE DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on round Windows logo in top left corner,

More information

CAMPUS COMMUNITY FIRE AND LIFE SAFETY POLICY

CAMPUS COMMUNITY FIRE AND LIFE SAFETY POLICY CAMPUS COMMUNITY FIRE AND LIFE SAFETY POLICY Origination Date: July 1 st 2009 1. PURPOSE The purpose of this policy is to create a safe environment for faculty, staff, students and visitors by applying

More information

ASSA ABLOY Series Power Operator Installation and Instruction Manual 6060 / Reveal. Adjusting Rod (08-13)

ASSA ABLOY Series Power Operator Installation and Instruction Manual 6060 / Reveal. Adjusting Rod (08-13) 6000 Series Operator Installation and Instruction Manual ASSA ABLOY 6060 / 6070 1 3 5 4 6 2 Item No. Description 1 2 Motor (6000M) Cover (6000COV) 3 4 Control Inverter (6000IN) Supply 24VDC (6000SUP) Reveal

More information

Surna 25-Ton Chiller Operating & Maintenance Manual

Surna 25-Ton Chiller Operating & Maintenance Manual www.surna.com 303.993.5271 Surna 25-Ton Chiller Operating & Maintenance Manual Models: 300F3-3. 300F4-3, 300FW-3 Revised: July 2015 Table of Contents Warranty Information 4 Limited Warranty 4 Limitation

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 75 ST - K0000 - Initial Comments Title Initial Comments Statute or Rule Type Memo Tag These guidelines are meant solely to provide guidance to surveyors in the survey process. ST - K0001 - OTHER

More information

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. WALL MOUNT SERIES www.windsterhood.com User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit is designed

More information

H BUTCH BROWNING FIRE MARSHAL BUILDING REHABILITATION

H BUTCH BROWNING FIRE MARSHAL BUILDING REHABILITATION STATE OF LOUISIANA Department of Public Safety and Corrections Office of State Fire Marshal Code Enforcement and Building Safety 8181 Independence Boulevard Baton Rouge, Louisiana 70806 225-925-4920 H

More information

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU BURGER KING BKSDU Burger King Shortening Disposal Unit (BKSDU) Operation, Service & Parts Manual Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified

More information

CODE ENFORCEMENT AND CERTIFICATION OF INSPECTORS FOR PUBLIC SCHOOLS, CHARTER SCHOOLS AND JUNIOR COLLEGES

CODE ENFORCEMENT AND CERTIFICATION OF INSPECTORS FOR PUBLIC SCHOOLS, CHARTER SCHOOLS AND JUNIOR COLLEGES DEPARTMENT OF PUBLIC SAFETY CODE ENFORCEMENT AND CERTIFICATION OF INSPECTORS FOR PUBLIC SCHOOLS, CHARTER SCHOOLS AND JUNIOR COLLEGES 8 CCR 1507-30 [Editor s Notes follow the text of the rules at the end

More information

Changes in NFPA

Changes in NFPA Changes in NFPA 72-2002 2002 Oregon Fire Code Committee November 25, 2003 Michael B. Baker, SET Automatic Fire Alarm Association MikeBaker@afaa.org 2003 Michael B. Baker 1 Table of Contents 1. Administration

More information

Specification, installation & maintenance of fire doors: Technical Note 2

Specification, installation & maintenance of fire doors: Technical Note 2 Specification, installation & maintenance of fire doors: Technical Note 2 March 2016 You & Your Care \\raptor\user data\users\kbyard www.bdct.nhs.uk Karen Byard: Fire Officer Tel: 07946 413 331 Karen.byard@bdct.nhs.uk

More information

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual Table of Contents 1. Introduction... 2 2. Getting Started... 2 2.1 Parts List... 2 2.2 Recommend Tools... 2 2.3 Thermometer Sensor

More information

CARD ACCESS CONTROL SYSTEM

CARD ACCESS CONTROL SYSTEM SECTION 13851 CARD ACCESS CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: A complete, operable, tested, integrated proximity access control system, to operate on a proximity principle where

More information

City of Rehoboth Beach

City of Rehoboth Beach City of Rehoboth Beach Building & Licensing 229 Rehoboth Ave Rehoboth Beach, DE 19971 Office: (302) 227-6181 x222 Fax: (302) 227-4504 www.cityofrehoboth.com Residential Rental Safety Certification Pictorial

More information

UL Revision 5. - Commercial Door Installations -

UL Revision 5. - Commercial Door Installations - UL325 2010 Revision 5 - Commercial Door Installations - UL325 - Scope - Door, Drapery, Gate, Louver, and Window Operators and Systems Covers electric operators for doors, draperies, gates, louvers, windows

More information

Installation Instructions

Installation Instructions Installation Instructions Built-In Dishwasher If you have questions, call 800-GECARES or visit our website at: www.geappliances.com BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT

More information

Service Manual Q MODEL DISPENSER Q160/290/300

Service Manual Q MODEL DISPENSER Q160/290/300 Q MODEL DISPENSER Q160/290/300 Service Manual Thank you for selecting a Manitowoc Dispenser, the dependability leader in ice making equipment and related products. With proper care and maintenance, your

More information

Department of Health Life Safety Code Update

Department of Health Life Safety Code Update Department of Health Life Safety Code Update Presented by: Charlie Schlegel, Director Division of Safety Inspection Overview CMS Adoption of the 2012 Life Safety Code (LSC) and 2012 Health Care Facilities

More information

TS93 EMF SERIES. INSPK NO Rev.03/10

TS93 EMF SERIES. INSPK NO Rev.03/10 TS93 EMF SERIES 1 Each hold open (HO) unit contains a door closer and track assembly with hold open solenoid. The unit can be connected directly to a fire control panel. 1) Read the entire instruction

More information

English. Your Model Number is: HD1500 IMPORTANT

English. Your Model Number is: HD1500 IMPORTANT Your Model Number is: HD1500 IMPORTANT Attention Valued Customer: The serial number of your machine and date of purchase is necessary information to facilitate warranty claims and the ordering of replacement

More information

Health Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE

Health Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE Health Chapter 420-5-22 ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE CHAPTER 420-5-22 SUBMISSION OF PLANS AND SPECIFICATIONS FOR HEALTH CARE FACILITIES TABLE OF

More information