Overview of NFPA 110 & 111
|
|
- Lucy Conley
- 6 years ago
- Views:
Transcription
1 Overview of NFPA 110 & 111 Michigan Chapter IAEI December 5, 2014 Tim McClintock Regional Electrical Code Specialist NaJonal Fire ProtecJon AssociaJon Phone:
2
3 NFPA 110 Standard for Emergency and Standby Power Systems NFPA 111 Standard for Stored Electrical Energy Emergency and Standby Power Systems Includes: General informajon and definijons on emergency and standby power systems Specific requirements for: Emergency power supply Switching and protecjon InstallaJon and environmental considerajons Maintenance and operajonal considerajons
4 NFPA 110 Chapters 1 & 2 General Requirements and Referenced Standards 3 & 4 DefiniJons & ClassificaJon of Emergency Power Supply Systems 5 Emergency Power Supply 6 Transfer Switch Equipment 7 InstallaJon and Environmental ConsideraJons 8 Maintenance and OperaJonal Requirements
5 NFPA 111 Chapters 1 & 2 General Requirements and Referenced Standards 3 & 4 DefiniJons & ClassificaJon of Stored Emergency Power Supply Systems 5 Emergency Power Supply: Energy Sources, Converters, and Accessories 6 Transfer Switch Equipment 7 InstallaJon and Environmental ConsideraJons 8 Maintenance and OperaJonal Requirements
6 NFPA 110 Scope 1.1 This standard covers performance requirements for emergency and standby power systems providing an alternate source of electrical power to loads in buildings and facilijes in the event that the primary power source fails. Power systems covered in this standard include power sources, transfer equipment, controls, supervisory equipment, and all related electrical and mechanical auxiliary and accessory equipment needed to supply electrical power to the load terminals of the transfer equipment. This standard covers installajon, maintenance, operajon, and tesjng requirements as they pertain to the performance of the emergency power supply system (EPSS).
7 NFPA 110 Scope 1.1 This standard does not cover the following: (1) ApplicaJon of the EPSS (2) Emergency lighjng unit equipment (3) DistribuJon wiring (4) UJlity service, when such service is permi_ed as the EPSS (5) Parameters for stored energy devices
8 NFPA 111 Scope 1.1 This standard shall cover performance requirements for stored electrical energy systems providing an alternate source of electrical power in buildings and facilijes in the event that the normal electrical power source fails. Systems covered in this standard shall include power sources, transfer equipment, controls, supervisory equipment, and accessory equipment, including integral accessory equipment, needed to supply electrical power to the selected circuits. This standard shall cover installajon, maintenance, operajon, and tesjng requirements as they pertain to the performance of the stored emergency power supply system (SEPSS).
9 NFPA 111 Scope 1.1 This standard does not cover the following: (1) ApplicaJon of the SEPSS (2) Emergency lighjng unit equipment (3) DistribuJon wiring (4) Systems having total outputs less than 500 VA or less than 24 V, or systems less than Class (5) Nuclear sources, solar systems, and wind stored- energy systems (6) UninterrupJble power systems (UPS) supplied by an emergency power supply system (EPSS)
10 NFPA 110 Directly referenced standards in NFPA 110: NFPA NFPA NFPA NFPA NFPA NFPA NFPA NFPA 110 directly referenced in: NFPA 20 NFPA 72 NFPA 99 NFPA 101 NFPA 5000 Also referenced in other model building codes
11 ObjecJves of Emergency and Standby Electrical Systems To provide an electrical distribujon system and alternate power source to loads deemed cri$cal to life safety. To provide an electrical distribujon system and alternate power source for supplying power to loads deemed essen$al for hazard abatement, or essen$al for conjnued operajon so as not to impede fire fighjng, and/or rescue operajons. To provide an alternate power source and electrical distribujon system for supplying power to loads deemed desirable for conjnued building occupancy and operajon.
12 NEC ArJcles on Emergency and Standby Electrical Systems ArJcle 700 Emergency Systems CriJcal ArJcle 701 Legally Required Standby Systems EssenJal ArJcle 702 OpJonal Standby Systems Desirable
13 Why Emergency and Standby Power? Emergency Building exijng Panic control Building safety systems (alarm, communicajons) Building mechanical systems (elevators, venjlajon) PrevenJon of catastrophic industrial process failure Legally Required Standby Building safety systems Building mechanical systems LighJng for conjnued occupancy Industrial processes OpJonal Standby Creature comfort Business conjnuity
14 Why Emergency and Standby Power? TradiJonal view on emergency has been prevenjng panic in large assembly occupancies and to get people safely out of buildings upon loss of normal power and/or building emergency. OpJonal standby has allowed for creature comfort and business conjnuity upon loss of normal power Recent events have raised concern over reliability, operajon, and approach to building emergency and standby systems WTC Bombing September 11, 2001 Threat of terrorist a_ack infrastructure and biological Katrina- devastajon of major US city
15 Emergency Systems Emergency System. Those systems legally required and classed as emergency by municipal, state, federal, or other codes, or by any governmental agency having jurisdicjon. These systems are intended to automajcally supply illuminajon, power, or both, to designated areas and equipment in the event of failure of the normal supply or in the event of accident to elements of a system intended to supply, distribute, and control power and illuminajon essenjal for safety to human life.
16 Emergency Systems 700 Provide illuminajon for building exijng and panic control Occupancies types requiring emergency illuminajon include but are not limited to: Assembly DetenJon and CorrecJonal EducaJonal Health Care MercanJle
17 Emergency Systems 700 May also be required to provide power for: VenJlaJon systems for maintaining human life Fire detecjon and alarm systems Elevators Fire pumps (not mandated by ArJcle 695) Public safety communicajons systems Industrial processes (non- orderly shutdown concern)
18 What Requires Article 700 Systems? Requirements comes from other codes. NFPA 101, Life Safety Code Chapter 7 Means of Egress 7.9 Emergency LighJng * Emergency lighjng facilijes for means of egress shall be provided in accordance with SecJon 7.9 for the following: (1) Buildings or structures where required in Chapter 11 through Chapter 42 Performance requirements for emergency lighjng specified in NFPA 101 or applicable building code.
19 2012 IBC SECTION 2702 EMERGENCY AND STANDBY POWER SYSTEMS InstallaJon. Emergency and standby power systems required by this code or the InternaJonal Fire Code shall be installed in accordance with this code, NFPA 110 and Where required. Emergency and standby power systems shall be provided where required by SecJons through
20 NFPA The emergency lighjng system shall be arranged to provide the required illuminajon automajcally in the event of any interrupjon of normal lighjng due to any of the following: (1) Failure of a public ujlity or other outside electrical power supply (2) Opening of a circuit breaker or fuse (3) Manual act(s), including accidental opening of a switch controlling normal lighjng facilijes
21 Emergency & Standby Systems Other NEC ArJcles: Applicable rules of Chapters 1 through Generators 517 Health Care FaciliJes 692 Fuel Cell 705 Interconnected Power ProducJon Sources
22 Emergency & Standby Systems Other NFPA Documents NFPA 37 StaJonary CombusJon Engines NFPA 99 Health Care FaciliJes NFPA 101 Life Safety Code NFPA 110 Emergency and Standby Power Systems NFPA 111 Stored Electrical Energy Emergency and Standby Power Systems NFPA 5000 Building ConstrucJon and Safety Code
23 NFPA & DefiniJons Emergency Power Source (EPS) Source of electric power Required capacity and quality Emergency Power Supply System (EPSS) Complete funcjoning system From the EPS to the transfer equipment Includes load terminals of transfer equipment
24 NFPA 110 Standard for Emergency and Standby Power Systems-Chapter 4 Covers from the EPS (source) to the line terminals of the transfer equipment EPSS is idenjfied by: Level Class Type NFPA On- site standby generator systems shall comply with SecJon 9.4 and shall meet the requirements of Level 1, Type 10, Class X systems of NFPA 110, Standard for Emergency and Standby Power Systems.
25 NFPA 110 Standard for Emergency and Standby Power Systems Covers from the EPS (source) to the line terminals of the transfer equipment Two levels of EPSSs Level 1 systems shall be installed where failure of the equipment to perform could result in loss of human life or serious injuries. Level 1 = ArJcle 700 in the NEC. Level 2 systems shall be installed where failure of the EPSS to perform is less crijcal to human life and safety. Level 2 = ArJcle 701 in the NEC. NFPA 110 is not required to be applied to ArJcle 702 OpJonal Standby Systems.
26 NFPA & ClassificaJon of EPSS Level 1 Most stringent equipment and performance requirements Loss of human life Serious injury Must be permanently installed
27 NFPA & ClassificaJon of EPSS, cont. Level 2 Where failure is less crijcal to human life and safety Involves the AHJ Permits a higher degree of flexibility Must be permanently installed
28 NFPA 110 Standard for Emergency and Standby Power Systems Other EPSS System Designa$ons: Class. The class defines the minimum Jme, in hours, for which the EPSS is designed to operate at its rated load without being refueled or recharged.
29 NFPA 110 Standard for Emergency and Standby Power Systems Other EPSS System Designa$ons: 4.3 Type. The type defines the maximum Jme, in seconds, that the EPSS will permit the load terminals of the transfer switch to be without acceptable electrical power. Table 4.1(b) provides the types defined by this standard.
30 NEC ArJcles on Emergency and Standby Electrical Systems ArJcle 700 Emergency System Power Available to Loads in Not More Than 10 Seconds ArJcle 701 Legally Required Standby Systems Power Available to Loads in Not More Than 60 Seconds ArJcle 702 OpJonal Standby Systems Power Available to Loads at DiscreJon of User
31 Emergency vs. Standby Emergency Legally Required Optional Required by NEC Yes Yes No Required by AHJ Yes Yes No Transfer Switch Auto Auto Auto or Manual Wiring System Separate Shared Shared Risk Life Safety Firefighter Efficiency Costs Business Continuity Periodic Test Required Power Available Time On Site Fuel Required Yes Yes No 10 Sec 60 Sec Not Specified 2 Hours 2 Hours Not Specified
32 NFPA Transfer switches Suitable for transferring loads Rated for the designed connected load Each switch in a separate enclosure or compartment Suitable for fault currents
33 NFPA & 6.2 Transfer switches, cont. Listed for emergency service where available Must be factory assembled and tested AutomaJc switches: Electrically operated; and Mechanically held
34 Transfer Equipment (A) Must be automajc IdenJfied for emergency Approved by the AHJ Designed and installed to prevent inadvertent connecjon Parallel operajon ArJcle 705 use c accordance
35 Transfer Equipment 700.5(A) & UL 1008
36 NEC ArJcles on Emergency and Standby Electrical Systems ArJcle 700 Emergency Systems AutomaJc Transfer only Emergency Loads ArJcle 701 Legally Required Standby Systems AutomaJc Transfer of Legally Required and OpJonal Standby Loads ArJcle 702 OpJonal Standby Systems AutomaJc or Manual Transfer
37 NFPA Chapter 7 InstallaJon and Environmental ConsideraJons Ø Minimum requirements and considerajons Ø Requires installajon acceptance Ø Provides on- site installajon test requirements
38 NFPA Indoor EPS Installation Level 1 installajon locajon Ø EPS must be installed in a separate room EPSS equipment permi_ed Ø Must be 2- hr rated room
39 NFPA Outdoor EPS Installation Level 1 installajon locajon, cont. Ø Installed in a suitable enclosure located outside the building and capable of resisjng the entrance of snow or rain at a maximum wind velocity as required by local building codes. Ø No other equipment, including architectural appur- tenances, except those that serve this space, shall be permi_ed in the EPS enclosure.
40 Wiring Design and LocaJon (C) Emergency system wiring performance requirement Designed and located to minimize hazards due to: Flooding Fire Icing Vandalism Other adverse condijons
41 Power Sources Equipment shall be designed and located so as to minimize the hazards that might cause complete failure due to flooding, fires, icing, and vandalism. NFPA 110 recommends: For natural condijons, emergency power supply system (EPSS) design should consider the 100- year storm flooding level or the flooding level predicted by the Sea, Lake, and Overland Surges from Hurricanes (SLOSH) models for a Class 4 hurricane.
42 Power Sources (A)- (F) Emergency Systems Storage ba_eries Generator sets UninterrupJble power supplies Separate service (acceptable to AHJ) Fuel Cells Unit Equipment
43 Power Sources Storage Ba_eries Load rajng for 1.5 hours without falling below 87.5% normal voltage AutomaJc ba_ery charger required Generator Sets On premise fuel supply for not less than 2- hour full- demand operajon Not permi_ed to be supplied by public gas ujlity or rely on municipal water ujlity (cooling) AutomaJc transfer between muljple fuel sources All necessary auxiliary equipment to be supplied from emergency power (fuel pumps, dampers for venjlajon)
44 Requirements change for Level 1 equipment Ø Not located in the same room with the normal service equipment where: The normal service equipment is rated over 150 volts to ground; and, Is equal to or greater than 1000 amperes
45 NFPA Rooms, shelters, or separate buildings housing Level 1 or 2 equipment Ø Designed and located to minimize damage from flooding caused by: Fire fighjng Sewer water backup Similar disasters or occurrences
46 NFPA Required illuminajon for indoor 1or Level 2 EPS equipment Level Ø Ba_ery- powered emergency lighjng Ø Charging system and normal lighjng in service to be connected on load side of transfer switch Ø Minimum lighjng level 3.0 q- candles
47 NFPA 110 Chapter 8 RouJne Maintenance and OperaJonal TesJng Ø Maintenance and operajonal tesjng IniJated aqer acceptance tesjng Requires a wri_en schedule to be established Ø Transfer switches subjected to a maintenance program
48 NFPA RouJne Maintenance and OperaJonal TesJng Ø Based on: Manufacturer's requirements InstrucJon manuals Minimum requirements of the chapter The AHJ
49 NFPA & OperaJonal InspecJon and TesJng Level 1 & 2 EPSSs Ø Inspected weekly Ø Exercised under load at least monthly Level 1 & 2 generator sets Ø Exercised monthly for 30 minutes
50 Tests and Maintenance AHJ to conduct or witness acceptance test and periodic tesjng thereaqer Scheduled periodic tesjng acceptable to AHJ Ba_ery maintenance Wri_en record to be kept Load tesjng under maximum anjcipated load Chapter 8 in NFPA 110 provides tesjng requirements for emergency power supply systems
NEC Requirements for Standby Power Systems. New England Building Officials Education Association Annual Conference October 5, 2015
NEC Requirements for Standby Power Systems New England Building Officials Education Association Annual Conference October 5, 2015 Emergency & Standby Power Systems Alternative power sources are utilized
More informationNFPA Updates (c) 2015 SSR, Inc. All rights reserved Florida AHCA Conf
Training presentation for: 2015 Florida AHCA Conference NFPA 110 Updates for 2016 David Stymiest, CHFM, CHSP, FASHE, (PE in LA MS MA) DStymiest@ssr-inc.com, cell 504.232.1113 Copyright 2015, Smith Seckman
More informationDavid Stymiest, PE, CHFM, CHSP, FASHE cell Copyright 2014, Smith Seckman Reid, Inc.; All rights reserved
AHCA 2014 Fall Conference Changes in Emergency Power Codes & Standards David Stymiest, PE, CHFM, CHSP, FASHE DStymiest@ssr-inc.com, cell 504.232.1113 Copyright 2014, Smith Seckman Reid, Inc.; All rights
More informationState of MN Energy Code Ventilation Review for 2017 Energy Design Conference. By 1. Mike D. Wilson Dakota Supply Group
State of MN Energy Code Ventilation Review for 2017 Energy Design Conference By 1. Mike D. Wilson Dakota Supply Group In accordance with the Department of Labor and Industry s statute 326.0981, Subd. 11,
More informationWhy Selective Coordination is Mandatory -- It Fills the Reliability Hole --
Why Selective Coordination is Mandatory -- It Fills the Reliability Hole -- The NEC has mandatory selective coordination requirements for the following systems. Emergency Systems- Article 700 700.27 Legally
More informationSLAB ON GRADE CONSTRUCTION Meeting the MN Energy Code ( air tightness) for 2017 Energy Design Conference. By Mike D. Wilson Dakota Supply Group
SLAB ON GRADE CONSTRUCTION Meeting the MN Energy Code ( air tightness) for 2017 Energy Design Conference By Mike D. Wilson Dakota Supply Group In accordance with the Department of Labor and Industry s
More informationSelecting And Applying Emergency Lighting Systems
bodine Selecting And Applying Emergency Lighting Systems A revision of an article originally published in Electrical Construction & Maintenance by David Crippen, CEO & Marketing Manager Contains updated
More informationINSPECTION AND TESTING FORM
INSPECTION AND TESTING FORM Date: Time: SERVICE ORGANIZATION Name: Address: Representative: License No.: MONITORING ENTITY Contact: Monitoring Account Ref. No.: TYPE TRANSMISSION McCulloh Multiplex Digital
More informationAre there any policies regarding outlets that contain USB ports?
Answers to the Questions Mark J. Blackburn, P.E., CFPS February, 2016 Question 1 Are there any policies regarding outlets that contain USB ports? There is no direct reference in code about these types
More informationGPS 140 NEC Requirements for Generators. Professional Development Seminar Series NEC Requirements for Generators
GPS 140 NEC Requirements for Generators WHAT YOU WILL LEARN NEC requirements for on-site power generation. Recent events have created increased interest in standby power This module organizes NEC requirements
More informationUltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW
12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes
More informationWORKING DRAFT OF COMMITTEE MEETING OUTPUT
WORKING DRAFT OF COMMITTEE MEETING OUTPUT CONTENT NOT FINAL SUBJECT TO REVISION PRIOR TO LETTER BALLOT AND PUBLICATION OF FIRST DRAFT REPORT Document: NFPA 110 (EPS-AAA) Revision Cycle: A2018 Meeting Date(s):
More information16620 EMERGENCY POWER SYSTEMS
16620 EMERGENCY POWER SYSTEMS PART 1: GENERAL 1.01 SUMMARY A. This Section provides the University guidelines for the installation of Emergency Power Systems. B. This standard is developed primarily to
More informationHeat pump for hot water With CO 2 as a refrigerant. Sergio Giro8o Enex srl
Heat pump for hot water With CO 2 as a refrigerant Sergio Giro8o Enex srl CONVENTIONAL HEAT WITH HFC FOR HOT WATER Heat pump combined with mixing tanks. CONVENTIONAL HEAT WITH HFC FOR HOT WATER In convenjonal
More informationFire Alarm Testing and Inspection Report
Fire Alarm Testing and Inspection Report Property Name: Property Address: Property Manager: Contact: Phone Number: Central Station: Phone Number: PELICAN ISLE II 35 DOCKSIDE RD. NAPLES, FLORIDA 3110 BILL
More informationSECTION AUTOMATIC TRANSFER SWITCHES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 This section specifies the furnishing, complete installation, and connection of automatic transfer switches. 1.2 RELATED WORK A. Section 14 21 00, ELECTRIC
More informationBest Practices for Specifying Emergency Power Systems
Best Practices for Specifying Emergency Power Systems Dave Carpenter Yancey Power Systems Agenda: 1. The Importance of Specific Emergency Power Specifications 2. Best Practices for being Specific in Emergency
More informationSECTION GENERATOR PARALLELING CONTROLS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 23 13 GENERATOR PARALLELING CONTROLS SPEC WRITER NOTE: Delete between // -- // if not applicable to project. Also delete any other item or paragraph not applicable
More information12/14/2013. Fire alarm and emergency power SPRINKLER HEAD
Fire alarm and emergency power SPRINKLER HEAD 1 Alert signal Alarm signal Fire detector Heat detector Smoke detector Smoke alarm 1. Detector locations 1. Fire detector locations (3.2.4.11) 2. Smoke detector
More informationBlack Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment
Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment February 2017 Alberta Fire Code safety equipment maintenance requirements: The Black Diamond Fire Department has
More information109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:
109-B Concord Drive Casselberry, FL 32707 407.830.6500 DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72 Pg 1 of 4 Equity One 11180600 Owner/Representative: WO#: _Customer#: 1550 NE Miami Garden Dr
More informationCalifornia Fire Code (CFC) Part III contains requirements. Building and Equipment Design Features PART. Chapters 5 through 19
PART 3 Building and Equipment Design Features Chapters 5 through 19 Chapter 5 Fire Service Features No changes addressed Chapter 6 Building Services and Systems Chapter 7 Fire-Resistance-Rated Construction
More informationEMERGENCY POWER SYSTEMS
263213 EMERGENCY POWER SYSTEMS PART 1: GENERAL 1.01 SUMMARY A. Section includes: 1. University guidelines for the installation of Emergency Power Systems (EPS). 2. Addresses the design and installation
More informationMulti-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.
M Series Multi-Output Access Control Power Supply Chargers Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 3 amp @ 12VDC or 4 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp
More informationEmergency procedures flowcharts
procedures flowcharts Joseph McHugh and Sandesh Sheth describe how to construct an emergency procedure flowchart. Introduction: procedures are the foundation of any crisis management plan. The objective
More informationGuide to Compliance with the Electrical Workplace Safety Standards in the United States
Guide to Compliance with the Electrical Workplace Safety Standards in the United States July 2011/1910DB1102 by Joseph H. Weigel, Product Manager Schneider Electric USA, Inc. Make the most of your energy
More informationMulti-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.
M Series Multi-Output Access Control Power Supply Charger Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 4 amp @ 12VDC or 3 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp @
More informationCHFM, CHSP, FASHE (PE
A PRESENTATION FOR TAHFM 2013 Interlink NFPA 110 Update + Expanding the Concept of EP Reliability David Stymiest, PE, CHFM, CHSP, FASHE (PE in LA, MS, MA) DStymiest@ssr-inc.com, cell 504.232.1113 Copyright
More informationWinnipeg Fire Department Fire Prevention Branch
Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of
More informationRelocation vs. Evacuation Drills Practice Makes Perfect Public Education Conference
Relocation vs. Evacuation Drills Practice Makes Perfect 2006 Public Education Conference Safety in Our Nation s Schools Every day, some school in the country has a police, fire, or ambulance-related emergency,
More informationOther EC and LS documents may be requested by surveyors, as needed, throughout the survey.
Documentation required by the Hospital Accreditation program Life Safety (LS) and selected Environment of Care (EC) standards is presented in the following pages. These documents will be reviewed by the
More information10/28/2015. Enjoy Your TJC Survey. Bill H. McCully CHFM SASHE. Senior Consultant MSL Healthcare Partners. MSL Healthcare Partners, 2015 PREPARATION
Enjoy Your TJC Survey Bill H. McCully CHFM SASHE Senior Consultant MSL Healthcare Partners PREPARATION 1 Top Eight Most Cited Standards (George Mills) EC News May 2015 Top Citations EC.02.06.01 56% EC.02.05.01
More informationRegulations Regarding Emergency Planning & Preparedness for Long Term Care Facilities. Regulation Explanation Document Reference
Regulations Regarding Emergency Planning & Preparedness for Long Term Care Facilities Mandatory Immediate Notifications to NJDHSS 8:39-9.4(e)1 8:39-9.4(e)4 Interruption for 3 or more hours of physical
More informationNEW ENERGY IN THE BATTERY INFRASTRUCTURE
NEW ENERGY IN THE BATTERY INFRASTRUCTURE Maurice H. Johnson Business Development Engineer UL LLC Northbrook, IL Paper Overview Over the past several years, there has been a significant effort to address
More informationUpdate all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.
11/16/12 TerraView First Revision No. 15-NFPA 720-2012 [ Global Input ] Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.
More information27th Annual AHCA Seminar
27th Annual AHCA Seminar NFPA 99 2012 Edition Overview and Discussion Presented by James Peterkin, PE Sr. Fire Protection Engineer Heery International Monday September 26, 2011 Disclaimer Not Speaking
More informationELECTRICAL POWER SYSTEMS
Scope The various Codes applicable to the University's electrical power system are mainly based upon a model of a single utility service, connected to a single premise. The University s electrical system,
More informationFirst Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement
of 43 10/20/2015 4:02 PM First Revision No. 2035-NFPA 101-2015 [ Global Input ] To 14.3.4.4.1, add an item (4) to read: (4) Carbon monoxide detectors shall be installed centrally located within occupiable
More informationArea-based management in ABNJ:
Area-based management in ABNJ: Creating coherence Marjo Vierros United Nations University Institute for the Advanced Study of Sustainability Tools for area-based management Environmental impact assessment
More informationSP-1000X. Panic Device Power Controller Installation Guide. Rev
TM SP-1000X Panic Device Power Controller Installation Guide Rev. 120213 Overview: SP-1000X will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed to handle the high current
More informationUnderstanding and Applying NFPA 25
Understanding and Applying NFPA 25 Texas Edition Learning Objectives Describe the scope of NFPA 25. Distinguish between sprinkler system problems that fall within the scope of NFPA 25 and those that do
More informationelite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems
5/25/16 rev 6 elite Model ELN General Specification 550 W to 1.5 KW elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems 1.0 General General Specification This specification
More information2.07 Permit Application Checklist for Diesel Generators, Diesel Fire Pumps, and Fuel Tanks Serving Generators and Fire Pumps (2016)
2.07 Permit Application Checklist for Diesel Generators, Diesel Fire Pumps, and Fuel Tanks Serving Generators and Fire Pumps (2016) Reference: Documents referenced for this bulletin are as follows: San
More informationSelecting & Applying Emergency Lighting Systems
Selecting & Applying Emergency Lighting Systems 10.1 Philips Emergency Lighting www.philips.com/bodine Philips Emergency Lighting 2 Emergency Lighting Mandated by State and Local Laws Emergency illumination
More information1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN
Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN 04-350 Product Installation
More information9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.
Chapter 1 GROUNDING AND BONDING 1 Proper grounding practices protect people from the hazards of electric shock and ensure the correct operation of overcurrent protection devices. Grounding is the intentional
More informationCandy Easterling K-063. Adequate and Reliable Water Supply for the Sprinkler System. CITY WATER or WATER TANK for Sprinkler System
Candy Easterling K-063 Adequate and Reliable Water Supply for the Sprinkler System CITY WATER or WATER TANK for Sprinkler System Life Safety Code Presentation 1 Fire Extinguishers K-064 2000 NFPA 101,
More informationDanilo B. Concepcion, CBNT, CCHT-A Operations Manager St. Joseph Hospital Renal Services
Life Safety Code Danilo B. Concepcion, CBNT, CCHT-A Operations Manager St. Joseph Hospital Renal Services danilo.concepcion@stjoe.org 714-771-8944 The findings and conclusions in this presentation are
More informationUltraLITE MODEL ELU. Centralized Emergency Lighting Inverters
1.5 kw 10 kw SINGLE PHASE UltraLITE MODEL ELU Centralized Emergency Lighting Inverters Seamless transfer, online double-conversion system, compatible with all existing lighting applications. Meets NFPA
More informationInstallation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger
Installation Guide for AL400ULM Multi-Output Access Control Power Supply Charger R AL400ULM - Multi-Output Access Control Power Supply/Charger Rev. 072500 Overview: The AL400ULM multi-output access control
More informationChapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations...
Article 90 Introduction...1 90.1 Purpose of the NEC...1 90.2 Scope of the NEC...2 90.3 Code Arrangement...4 90.4 Enforcement...5 90.5 Mandatory Requirements and Explanatory Material...6 90.6 Formal Interpretations...6
More informationInformational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017
Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017 It has come to the attention of the electrical authorities having jurisdiction (AHJs) at the DOE sites there is inconsistency
More informationMoreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline
Moreno Valley Fire Department Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: May 8, 2017 Alarm & Signaling Systems PURPOSE Fire alarm and signaling systems are designed to
More informationBattery charger modules
Battery charger modules D8132 and D8132LT en Installation manual Battery charger modules Notices en 3 1 Notices These instructions cover the installation of the D8132 Battery Charger and the D8132LT Battery
More informationObjectives. To review updated IBC and fire test requirements when designing for life safety.
Objectives To review updated IBC and fire test requirements when designing for life safety. To understand the relationship of fire safety and human impact safety. To clarify the difference between fire
More informationFire Alarm System Fundamentals
Fire Alarm System Fundamentals Mircom is the largest and oldest privately owned fire alarm and life safety manufacturer in North America and 5th largest overall with 50 years of industry experience. Mircom
More informationEC Standard & NFPA 110 (EPSS) Documentation Best Practice. 1: Division Team Mission
EC.02.5.07 Standard & NFPA 110 (EPSS) Documentation Best Practice 1: Division Team Mission Presenters Pouyan Layegh, P.E., MBA, LEED AP Director, Campus Services Facilities Management UT MD Anderson Cancer
More informationTOM BURNS, PLANNING DIRECTOR
~~ 0 173 COUNTY OF SANTA CRUZ August 4,2005 PLANNING DEPARTMENT 701 OCEAN STREET, qth FLOOR, SANTA CRUZ, CA 95060 (831) 454-2580 FAX: (831) 454-2131 TDD: (831) 454-2123 TOM BURNS, PLANNING DIRECTOR Agenda:
More informationDIESEL Engine Fire Pump Controllers Features
September 007 DIESEL Engine Fire Pump Controllers Features FD0 Diesel Engine Controllers 1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller.
More informationAL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev
AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 031703 Overview: The Altronix AL802ULADA is an extremely cost effective 8 amp voltage regulated
More informationElectrical Safety Through Design. Mersen EP formerly Ferraz Shawmut
Electrical Safety Through Design Mersen EP formerly Ferraz Shawmut Agenda Who is Mersen? Selective Coordination Code Requirements Coordination Made Easy Mitigating Arc Flash Energy on Transformer Secondary
More informationInstallation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger
Installation Guide for AL300ULM Multi-Output Access Control Power Supply Charger R AL300ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL300ULM multi-output access control power supply/charger
More informationUltraLITE. Centralized Emergency Lighting Inverters MODEL ELU
1.5 kw 14 kw SINGLE PHASE UltraLITE MODEL ELU Centralized Emergency Lighting Inverters True no-break system, with regulated output and transient voltage protection for LED lighting, electronic ballasts,
More informationFacilities Management
Facilities Management Policy Number: 700.4 Title: Fire Protection & Life Safety Inspection Policy Implementation Date: August 1 st, 2008 Last Revised: September 14 th, 2017 Last Audited: August, 2017 Introduction
More informationMA Electric Code Challenges for Architects
MA Electric Code Challenges for Architects Boston Society of Architects Codes Committee March 19, 2013 Presented by Doug Anderson 313 Congress Street Boston, MA 02210 617.330.9390 617.330.9383 fax www.c3boston.com
More informationNFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities
Fire Alarm and Signaling Code Overview NFPA 72-2010 usa.siemens.com/infrastructure-cities Siemens Building Technologies, Inc. is a Registered Provider with The American Institute of Architects Continuing
More informationSOMERSWORTH CODE FIRE PREVENTION AND LIFE SAFETY CHAPTER 21
SOMERSWORTH CODE FIRE PREVENTION AND LIFE SAFETY CHAPTER 21 ARTICLE I FIRE PREVENTION CODE 21-1. Statutory authority 21-2. Adoption of standards 21-3. Definitions 21-4. Exceptions to Fire Prevention Code
More informationFirst Revision No. 158-NFPA [ Global Input ] Submitter Information Verification. Committee Statement
of 326 11/21/2013 1:03 PM First Revision No. 158-NFPA 72-2013 [ Global Input ] Revise 2.3.1 to update UL 864 to "2003, revised 2012" and upate ANSI/ASME A17 to 2013. Submittal Date: Wed Sep 11 11:08:52
More informationBrighton Area Fire Authority
615 W. Grand River Ave. Brighton, MI 48116 o: 810-229-6640 f: 810-229-1619 January 14, 2019 Fire Alarm Contractors RE: Fire Alarm Credential & Submittal Requirements To Whom It May Concern: The following
More informationOsceola County Department of Fire Rescue and Emergency Medical Services
St. Number Dir Street Name Street Type Inspected Time of Day to be Re-inspected Zip Code Occupancy Type Emergency Contact Phone (Inc. Area Code) Building Owner Building Owner Mailing Address Bldg. Owner
More informationPolicy and Organizational Statements
Company Name Address Telephone Contact Name Title Last Revision Date Policy and Organizational Statements Identify the goals and objectives for the emergency response plan. Define what your emergency response
More informationHealthcare Emergency Power Supply Systems. Maintenance and Testing
Healthcare Emergency Power Supply Systems Maintenance and Testing Maintenance and Testing NFPA 110, 8.1.1 NFPA 110, 8.1.1 The routine maintenance and operational testing program shall be based on all of
More informationPRINTED: 06/09/2017 FORM APPROVED CENTERS FOR MEDICARE & MEDICAID SERVICES OMB NO (X2) MULTIPLE CONSTRUCTION A. BUILDING 03 - A BUILDING
SUMMARY PROVER'S PLAN OF CORRECTION K 000 INITIAL COMMENTS K 000 A Life Safety Code Survey was conducted by the State Fire Marshal beginning on May 9th, 2017 and ending on May 10th, 2017. Adair Acute Care
More informationJanuary 1, 2014 Mandatory Effective Date
2013 Kentucky Building Code Highlights Winnie Blythe, Technical Advisor Dept. of Housing, Buildings, and Construction winnie.blythe@ky.gov www.dhbc.ky.gov 502-573-0373 January 1, 2014 Mandatory Effective
More informationUnderstanding NFPA, NEC 2005 Article 409 a White Paper by Paul A. Terry, P.E.
a White Paper by Paul A. Terry, P.E. NFPA 70, NEC 2005: Article 409 Industrial Control Panel Short Circuit Panel Ratings Executive Summary Many panel shops are providing industrial control panels with
More informationGuide Specification Model CTG Automatic Transfer Switch
Guide Specification Model CTG Automatic Transfer Switch PART 1 GENERAL 1.1 Scope A. It is the intent of this specification to secure a transfer switch that has been prototype tested, factory built, production
More informationSECTION AUTOMATIC TRANSFER SWITCHES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between //--// if not applicable to project. Also, delete any other item or paragraph
More informationENGINE GENERATORS AND ACCESSORIES
ENGINE GENERATORS AND ACCESSORIES GENERAL INFORMATION 1.1 This section applies to engine generators and accessories. DESIGN REQUIREMENTS 2.1 The Engineer of Record will consult with the University s Engineering
More informationFACT SHEET Program: Event Fire Safety
FIRE AND LIFE SAFETY GUIDELINES FOR EVENTS INTRODUCTION The purpose of this fact sheet is to provide information for a safe environment for events and insure compliance with fire safety standards and regulatory
More informationAlarm. A warning of danger. An indication of the existence of a condition that requires immediate action. (SIG-FUN)
4 of 326 11/21/2013 1:03 PM First Revision No. 161-NFPA 72-2013 [ Section No. 3.3.11 ] 3.3.11 Alarm. A warning of danger. An indication of the existence of a condition that requires immediate action. (SIG-FUN)
More informationWritten Fire Safety Plans
Written Fire Safety Plans 2012 LSC KATHARINE ACHOR SEPTEMBER 2016 NFPA Standard: 2012 NFPA 101, 19.1.1.3.1 All health care facilities shall be designed, constructed, maintained, and operated to minimize
More informationORDINANCE NO. _ THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:
182851 ORDINANCE NO. _ An ordinance amending certain provisions of Article 3, Chapter IX of the Los Angeles Municipal Code to reflect local administrative changes and incorporate by reference portions
More informationUFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCESA / NASA UFGS-26 28 21.00 40 (August 2008) ----------------------------------- Preparing Activity: NASA Superseding UFGS-26 28 21.00 40 (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS
More informationIowa State Fire Marshal
Iowa State Fire Marshal LIFE SAFETY CODE REQUIREMENTS LONG TERM CARE Kyle R. Gorsh, Special Agent in Charge Iowa Department of Public Safety State Fire Marshal Division 2012 LSC & Applicable Standards
More informationMt. Crested Butte Code
Mt. Crested Butte Code Chapter 8 FIRE PREVENTION AND PROTECTION ARTICLE I. IN GENERAL Note * Editor s note Ord. No. 12-05, 1, adopted October 2, 2012, repealed former Ch. 8, Art I in its entirety, and
More informationTG FIRE DRILLS. Office of the Fire Marshal and Emergency Management
FIRE DRILLS Office of the Fire Marshal and Emergency Management Preface This guideline updates TG-01-2004 published in October 2004. Portions of the guideline have been changed to reflect the current requirements
More informationFee $15 Course: NEC Changes 5 This course is valid for these credentials: Credential Description Cred Code Credit Hours
www.garyklinka.com Page 1 of 9 Instructions: Fee $15 1. Print these pages. 2. Circle the correct answers and transfer them to the answer sheet. 3. Page down to the last page for the verification forms
More informationNFPA 96, 2017 REVIEW SUMMARY
NFPA 96, 2017 REVIEW SUMMARY 1) NFPA 96 REVISION SUMMARY NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations The 2017 edition adds a new normative annex on mobile
More informationQuestions/Comments for Richard Roux from Webinar on 7/11/13
Questions/Comments for Richard Roux from Webinar on 7/11/13 Below are the questions and comments from the July 11, 2013 webinar 2013 NFPA 72: Design and Installation Requirements for Mass Notification
More informationUFGS (August 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-26 28 21.00 40 (August 2014) --------------------------------- Preparing Activity: NASA Superseding UFGS-26 28 21.00 40 (August 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS
More informationAPPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL
This Appendix (2000 IRC Appendix-L) is produced, copyrighted, and maintained by the National Fire Protection Association Association, all rights reserved. Use of this Appendix is pursuant to license with
More informationAL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs
ACM Series Access Power Controllers with Power Supplies Installation Guide Models Include: AL400ULACM AL600ULACM - 12VDC @ 4 amp - 12VDC or 24VDC @ 6 amp. or 24VDC @ 3 amp - Fused Outputs - Fused Outputs
More informationBALTIMORE CITY RENTAL LICENSE INSPECTION FORM RENTAL LICENSING INSPECTOR GUIDANCE
BALTIMORE CITY RENTAL LICENSE INSPECTION FORM RENTAL LICENSING INSPECTOR GUIDANCE Checklist items A - L may receive a result of Pass or Fail A. Railing is present for interior and exterior steps with more
More information2017 NEC: Impact to Electrical System Designs
2017 NEC: Impact to Electrical System Designs We will begin shortly. Turn up your speakers in order to hear the hold music. Feel free to ask questions now in the Q&A widget! Today s broadcast is sponsored
More informationFIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures
FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures Building Name: Building Address: Plan Prepared By (please print): Date: Revision Date Comments Approval FIRE SAFETY MAINTENANCE
More information10/25/2018. Facilitators. Emergency Preparedness &Life Safety Code for Administrators. Participant Guide
Emergency Preparedness &Life Safety Code for Administrators 1 Participant Guide Emergency PreparednessHandouts Graphic Organizer Sample Checklist for Emergency Preparedness Regulation Compliance Crosswalk
More informationAccessories & General Information
Accessories & General Information Lamp Data...108-109 Unit Accessories...110 Mounting Plate Series...111 Wire Guards...1-113 Wire Size Guide...114 National Electrical Code...115-116 Life Safety Code...117-119
More informationSECTION AUTOMATIC TRANSFER SWITCHES
SECTION 26 36 23 AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationFiber Distribution Box
Outdoor Enclosures Fiber Distribution Box Amphenol s Fiber Demarcation Boxes offer superior protection for indoor or outdoor equipment installations. These sealed polymer enclosures provide a long life,
More informationASCO Series 185 Power Transfer Switches
ASCO Series 185 Power Transfer Switches 24-hour protection no matter when trouble strikes ASCO Series 185 POWER TRANSFER SWITCHES An Automatic Transfer Switch helps prevent... Your business or home from
More information