1 Fibre Specification Standards User Manual The most important thing we build is trust Cobham Wireless - Coverage
2 Table of Contents 1. Single-mode Fibre to ITU-T Recommendation G SC/APC Mated Pair Requirements 3 3. Single-Mode Fibre Requirements 4 4. Fibre Connector End face Inspection Zones and Grading Fibre Inspection Acceptance Criteria 5 Page 2 of 6
3 1. Single-mode Fibre to ITU-T Recommendation G.652 For optimal performance and ease of commissioning, Cobham Wireless recommends that the fibre optic link between the Optical Master and the remote repeater comprises of a single fibre run with fusion splicing of fibre to ensure optimal reflectance of the link performance. The fibre link must use Single mode fibre which meets the requirements of ITU-T Recommendation G.652.D. All fibre connectors must be APC type with SC/APC interfaces to the Cobham Wireless equipment and be certified compliant to IEC APC specifications The use of optical patch panels to join adjacent lengths of fibre can lead to performance degradation and failure of inter equipment communication. Should alternative methods of fibre cable joining be used, they must meet the requirements of the table below: Fibre Link Specification Fibre Type Fibre Connectors Optical Loss Transition Reflectance Number of APC connections Requirement 9/125um G625.D SC/APC (8º Angled Physical Contact) 10dBo maximum > 60 db 6 maximum (including equipment interface) Please make the necessary measurements to ensure a correct installation of the fibre distribution system. When the fibre cable has been installed, the quality of the optical path should be checked for optical path loss over the entire length and the magnitude and location of any reflections. Prior to any commissioning and support activity, Cobham Wireless requires Optical Time Domain Reflectometer (OTDR) measurement of each optical link in both directions across the operating optical wavelengths. Ensure that the OTDR pulse width is applicable to the measurement distance to ensure accurate results. Notes: Keep all discrete reflections to > 60 db. The SC/APC connectors specified are polished to a return loss > 60 db. 2. SC/APC Mated Pair Requirements Mated Pair SC/APC Specification APC Angle Optical Loss (Typical) Optical Loss (Maximum) Transition Reflectance Requirement 8º Angled Physical Contact 0.15dBo 0.35dBo > 60 db NB / Fusion Splice required = 0.1dBo Page 3 of 6
4 3. Single-Mode Fibre Requirements Throughout this manual, important safety warnings and admonishments are included to warn of possible hazards to persons or equipment. A safety warning identifies a possible hazard and then describes what may happen if the hazard is not avoided. The safety warnings in the form of Dangers, Warnings and Cautions must be followed at all times. These warnings are flagged by the use of a warning icon, usually the triangular alert icon seen below. The exclamation point within the triangular alert icon is intended to warn the operator or service personnel of operation and maintenance from factors relating to the product and its operating environment, which could pose a safety hazard. Applicable Standards and Norms: ITU-T Recommendations G.652.D IEC/EN cat B.1.3 IEC The following details summarise the main Optical, Geometrical and Physical Characteristics of fibres, compliant to the above standards. Fibres are manufactured from high grade silica, doped as necessary to achieve the required light guiding properties, designed with a matched-cladding, step-index profile. The fibre coating is a dual layer structure of ultra-violet cured acrylate resin. The lower modulus inner layer being optimised for both adhesion to the fibre surface and mechanical stripping using the appropriate stripping tools. The outer layer is optimised for abrasion resistance and fibre processing properties. Certain Cobham Wireless products require a wide range of optical frequencies for WDM operation, the optical fibre must be suitable for operation at the following wavelengths: nm and nm. Attenuation Requirements Wavelength Typical Attenuation Maximum Units Attenuation nm 1310nm 0.40 max db/km nm 1550nm 0.30 max db/km Other Requirements Fibre Property Value Coating diameter 235 to 255 nm Coating diameter coloured 250 ± 15 nm Coating concentricity error 10 μm Coating non circularity 6% Mode Field 1310 nm 8.6 to 9.5 μm Cladding diameter ± 1.0 μm MFD/cladding concentricity error 0.6 μm Cladding non-circularity error 1.0 % Cable cut-off wavelength (method A) 1260 nm Attenuation at 1383 nm 0.40 db/km Attenuation uniformity < 0.1dB/km at 1310 nm and 1550 nm Point discontinuity < 0.1dB at 1310 nm and 1550 nm Dispersion ps/nm.km Dispersion ps/nm.km Zero Dispersion Wavelength 1300 to 1324 nm Zero Dispersion Slope S ps/(nm2.km) Polarisation mode dispersion 0.06 ps/ km (link value) Proof test 1.0% Strain equivalent 100 turns x 60mm diameter < 0.05 db at 1550 nm Page 4 of 6
5 4. Fibre Connector End face Inspection Zones and Grading Inspection zones are a series of concentric circles that identify areas of interest on the connector end face. The inner-most zones are more sensitive to contamination than the outer zones. It is common to divide the image into a series of concentric circles that begin with a small one centered on the core (also known as zone A ) and then radiate out from there. This creates a bulls-eye pattern sometimes called a grading overlay. The overlay is used to GRADE the fibre by determining the number and size of each particle that are present in each of the 4 fiber zones Figure 1 Fiber End face Inspection Zones for Single-Fibre Connection 4.1 Fibre Inspection Acceptance Criteria Acceptance Criteria are a series of failure thresholds that define defect limits for each zone on the fibre connector end face. All loose particles must be removed. If defect(s) are non-removable, it must be within the criteria specified below to be acceptable for use. The tables below list the Acceptance Criteria standardized by the International Electro technical Commission (IEC) for single-mode and multi-fiber single mode connectors as documented in IEC Ed All fibre connectors shall be inspected and a PASS Certification report should be produced to prove compliancy with these criteria before being deployed in the network. Single-Mode APC Connectors: IEC Page 5 of 6
6 Single-Mode (APC) Zone Name (Diameter) Scratches Defects A Core Zone (0-25µm) 4< 3µm None B Cladding Zone (25-120µm) No limit No limit <2 µm 5 from 2-5 µm None >5 µm C Adhesive Zone No limit No limit ( µm) D Contact Zone ( µm) No limit None =>10 µm All loose particles must be removed. If defect(s) are non-removable, it must be within the criteria above to be acceptable for use. For scratches the requirements refer to width. No visible surface cracks are allowed on the core or cladding zone. There are no requirements for the area outside the contact zone since defects in this area have no influence on optical performance. Cleaning loose debris beyond this section is recommended good practice. The limit for non-linear non-removable features in the ferrule/contact zone (D) does not apply for metal-alloy ferruled connectors. Page 6 of 6
Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red
OFC-UT-CST Fire resistant Armoured Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU
More informationThe True Value of Connector Inspection: New Challenges and Best Practices
The True Value of Connector Inspection: New Challenges and Best Practices Vincent Racine Product Line Manager August 2011 1 Table of contents 1 Best Practices 2 Connector Inspection Tools 3 Connector Inspection
More informationDuct Cable GYTS-144B1.3
Optical Fibre Cable Technical Specification Duct Cable GYTS-144B1.3 Xcom Ltd All rights reserved 1. Scope This Specification covers the design requirements and performance standard for the supply of optical
More informationOptical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3
VersionGYTA-72B1.3 Optical Fibre Cable Technical Specification Duct Cable GYTA-72B1.3 Yangtze Optical Fibre and Cable Joint Stock Limited Company All rights reserved www.yofc.com All Rights Reserved Copyright
More informationSumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003
Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber PureGuide SM Optical Fiber, TIA Type IVd Issued: November 2003 78 Alexander Drive, Research Triangle Park, NC 27709 Phone
More informationEnsuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications
Ensuring Cabling Performance in the Customer-Owned Outside Plant Keith Foord Product Manager Greenlee Communications Introduction: Outside plant fiber networks require low reflectance terminations for
More informationVTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links
VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links TB Number 004 This bulletin is supplied for information only and is intended to provide
More informationSumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber
Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber PureGuide -LA SM Optical Fiber, TIA Type IVd ITU G.655 C and D Compliant Issued:
More informationEnsuring Cabling Performance in the Customer-Owned Outside Plant
Ensuring Cabling Performance in the Customer-Owned Outside Plant Needs to be able to qualify the installation to validate bandwidth requirements are met Future high bandwidth applications Future Proof
More informationSTANDARD TEST PROCEDURE PRE-TEST QUALITY OF OPTIC FIBRE CABLE ON DRUMS TYPE OF CABLE :
PROCEDURE PRE-TEST QUALITY OF OPTIC FIBRE CABLE ON DRUMS STANDARD TEST PROCEDURE PRE-TEST QUALITY OF OPTIC FIBRE CABLE ON DRUMS TYPE OF CABLE : 1) SINGLE MODE 2) MULTI-MODE IN EXCESS OF 100 METRES PRC-00107
More informationHELKAMA. Optical Fibre Cables
1 Contents Optical fibres and their characteristics Cable constructions Cable tests Installation, jointing and terminating Manufacturing (pictures) 2 Multimode Fibre (GK) Attenuation and Bandwidth Fibre
More informationA Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification
A Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing Vol. 2 Tier 2 Certification A Quick Start Guide to Fiber-to-the-Antenna enna (FTTA) Installation and Maintenance Testing
More informationFiber Optic Patch Cord and Pigtails
Fiber Optic Patch Cord and Pigtails Description The optical fiber patch cords are fitted at both ends with same connector types or different connector types. Our fiber optic patch cords are ultra reliable
More informationA Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification
A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing Vol. 2 Tier 2 Certification Notice Copyright Every effort was made to ensure that the information in this document
More informationOptical Return Loss Measurement by Gregory Lietaert, Product Manager
White Paper Optical Return Loss Measurement by Gregory Lietaert, Product Manager Introduction With the increasing frequency of high-speed transmission systems and DWDM deployment, optical return loss (ORL)
More informationData sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1
Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors
More informationAccelerating NBN fiber testing. Tom Ronan Marketing Lead Fiber Optics Melbourne
Accelerating NBN fiber testing and workforce Performance. Tom Ronan Marketing Lead Fiber Optics Melbourne Agenda Network Elements and Parameters Distributed Fiber Network (DFN) Construction Network Activation
More informationField Test Procedure for Optical Fibre Link Measurements
Application Notes Field Test Procedure for Optical Fibre Link Measurements Issued April 2014 Abstract After fiber optic cables are installed, spliced and terminated, they must be tested. For every fiber
More informationReflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010
Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010 Adrian Young Sr. Customer Support Engineer Foreword Reflectance is measured using an Optical
More informationData sheet OpDAT universal cable 1x24 OM4 - bend insensitive
Illustrations Principle diagram Page 1/7 Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or stranded loose tube bend insensitive fiber
More informationBasic Professional Fiber Optic Installation
Basic Professional Fiber Optic Installation QUICK SUMMARY Length: 32 hours; or 40 hours with Fiber Optic Association CFOT certification Hands-on Activities: 40 activities, 70-75 % Text/Field Reference:
More informationLAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS
1/10 FACULTY OF ENGINEERING LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS TRIMESTER 3, SESSION 2016/2017 Student Name: Student ID: Degree Major (please circle): EE
More informationEXECUTING HIGHLY ACCURATE FIBER MEASUREMENTS IN A FRACTION OF THE TIME
10 /0 /100Gb/s transmission links are typically shared by a vast number of application and users. EXECUTING HIGHLY ACCURATE FIBER MEASUREMENTS IN A FRACTION OF THE TIME Claiming that they are most of the
More informationThe Rise of Tier 2 Testing
The Rise of Tier 2 Testing Why enterprises today demand better visibility into their fiber infrastructure Unprecedented demand for more bandwidth, faster network speeds, lower latency, and improved data
More informationM700-Series Multifunction OTDR
M700-Series Multifunction OTDR Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks Test Modes Full Auto OTDR Normal (point-to-point) fiber cable construction testing and fault location
More information2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK
PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway
More informationDraft ES V1.1.1 ( )
Standard Transmission and Multiplexing (TM); Passive optical components; Fibre optic mechanical splices for single-mode optical fibre communications systems; Common requirements and conformance testing
More informationFibre (TIA) Field Test Specification
This document has been prepared to aid consultants or engineers in developing contractual specifications covering the testing of duplex fibre optic cabling installations. It is offered as a general guide.
More informationFibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager
Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC Philip C Longhurst Corporate Fibre Optic R & D Manager Outline CENELEC TC86BXA work programme IEC SC86B WG 6 and
More informationFibre Optic Basics FIA Summer Seminar 2014
Fibre Optic Basics FIA Summer Seminar 2014 Andrew Cole Theory Basics Characteristics of Light What is Light? An electromagnetic wave, which like other waves, has a frequency (f), velocity (v) and a wavelength
More informationRLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507
RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable Reference Guide MD-019 2014A 0507 RLH Industries, Inc. Copyright 2013 RLH Industries, Inc. All rights reserved. No part of this document may
More informationThe Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise
The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise 1 The purpose of the exercise...2 2 Background...2 2.1 Introduction to scattering and attenuation...2 2.2 Introduction to
More informationoutdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free
GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection 05-04-8 v0.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4
More informationMOST EFFECTIVE METHOD FOR WIPING A FIBRE
MOST EFFECTIVE METHOD FOR WIPING A FIBRE Step 1: Pull & fold a new wipe Step 2: Apply the cleaning fluid Step 3: Wipe the fiber in single direction Avoid oversaturating the wipe Insert the fiber into the
More informationData sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive
Page 1/8 Illustrations Principle diagram See enlarged drawings at the end of document Product specification mini-breakout installation cable U-VQ(ZN)H laser-optimized, bend insensitive fiber UV-resistant,
More informationITU-T L.404. Field mountable single-mode optical fibre connectors
I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T L.404 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (08/2017) SERIES L: ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY
More informationMT-RJ Optical Fiber System Field Testing
MT-RJ Optical Fiber System Field Testing Table of Contents INTRODUCTION... 3 TEST JUMPERS... 4 LAUNCH CONDITIONS... 4 MT-RJ TEST KITS... 5 MT-RJ SYSTEM TESTING: Fixed transmit and receive (SC or ST-style)
More informationSpecial Provision No. 683S28 December 2017
FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE - Item No. FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE (TEMPORARY) - Item No. Special Provision No. 683S28 December 2017 1. SCOPE
More informationAttenuators. Fiber Optic Products Catalog. Singlemode Build Out Attenuators. Product Facts. Applications. Customizable Features. Available Collateral
Attenuators Build Out Attenuators Product Facts A range of fixed attenuation values. Standard values of 1 through 20 and 25dB UPC and APC offer Excellent Return Loss LC, SC, FC, ST, and D4 styles Attenuation
More informationSECTION TESTING OF FIBER OPTIC CABLES
SECTION 27 08 23 TESTING OF FIBER OPTIC CABLES PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction,
More informationSpecification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.
Specification No.CSC-131/R-1/DH//UH/P&D/2016-17 Technical Specifications for 24 Fiber/48 Fiber Unarmoured Underground Fibre Optic Cabling Issue Month:June-2016 (CSC Amendment date 14.06.2016) Common Specification
More informationFACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014)
FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014) OC1 FIBER LINK CHARACTERIZATION WITH OTDR *Note: On-the-spot evaluation may be carried out during or at the
More informationGUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.
GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection 07-07-05 v3.0 Ordering Information Belden Part Numbers Fibre Description
More informationOPX-BOX. Platform Highlights. Software Support. Key Features
Ultra Compact, Highly Versatile OTDR with Bluetooth Wireless and USB Control The VeEX is an ultra-compact, OTDR designed to operate remotely using Fiberizer software. The unit can be controlled via USB
More information4120 Fire Alarm Network Reference
4120 Fire Alarm Network Reference Features Autocall 4120 Fire Alarm Network communications are available for wired or fiber optic connections Wired communications are available on Network Interface Cards
More informationGCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.
GCRG Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection 05-05-7 v7.0 Ordering Information Belden Part Numbers Fibre Description / count 4 8 8 4 30 36 6.5/5-OM GCRG04
More informationM210 Multifunction Micro OTDR
Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks Features 30 db dynamic range single-mode 16-hour battery life Remote display capable Touch and Test intuitive user interface New
More informationFTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION
C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION GLOBAL PORTABLE FIBER OPTIC TEST EQUIPMENT MARKET LEADERSHIP AWARD NEW OTDR GENERATION Tunable DWDM OTDR for testing through MUX/DEMUX channels to provide
More informationWhite Paper: Fiber Contamination, Cleaning and Inspection. Introduction.
White Paper: Fiber Contamination, Cleaning and Inspection. Introduction. Despite industry best practice of inspecting and cleaning fiber optic endfaces, contaminated connections remain the number one cause
More informationAcceptance Requirements. Fibre Optic Systems. Revised 12/2017. December 5th, Alexander Kölbel
December 5th, 2017 Acceptance Requirements Fibre Optic Systems Revised 12/2017 Alexander Kölbel +49 6190 8880-40 alexander.koelbel@datwyler.com Dätwyler Cables GmbH, Auf der Roos 4-12, 65795 Hattersheim,
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO/IEC 14763-3 First edition 2006-06 Information technology Implementation and operation of customer premises cabling Part 3: Testing of optical fibre cabling Reference number ISO/IEC
More informationConnections You Can Count On.
Connections You Can Count On. XPRESS ULTRA FIBER CONNECTOR PRODUCT GUIDE - CLEANING & INSPECTION - TESTING AND TROUBLE SHOOTING - XPRESS ULTRA FIBER CONNECTORS - INSTALLATION KITS Connections You Can Count
More informationOPTICAL TIME DOMAIN REFELECTOMETER (OTDR): PRINCIPLES
OPTICAL TIME DOMAIN REFELECTOMETER (OTDR): PRINCIPLES Why Test Fiber with an OTDR? Single ended test that......characterizes fiber from end-to-end...locate and measure each event...provides a detailed
More informationClearlite Photonic Fibers
Clearlite Photonic Fibers Fiber Name Operating Wavelength MFD at Operating Wavelength Beat Length at Operating WL Clad/Coating Diameter Order by Part Number TruePhase 980 Micro TruePhase 980 400 TruePhase
More informationECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS
Network(s): Summary: ENGINEERING COMMISSIONING PROCEDURE ECP 11-0009 OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS EPN, LPN, SPN This standard details the requirements for the splicing,
More informationM210 Multifunction Micro OTDR
Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks Features 30 db dynamic range single-mode 16-hour battery life Remote display capable Touch and Test intuitive user interface New
More informationFTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD
FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD 157 APPLICATION NOTE Mario Simard, Product Manager, Optical Business Unit The purpose of any fiber-optic network is to perform high-speed,
More informationBest Practice Briefing
Best Practice Briefing Fiber Optic Connector Handling, Inspection, andcleaning microwave photonic systems Expand Your RF Horizons Briefing Overview Personnel Safety & Best Practices Insertion Loss (IL)
More informationFiber Optics for Todays Industry Applications
Hands-On Fiber Optics for Todays Industry Applications (A Non-Telephone Company Course) Course Description This Hands-On course is designed to provide technicians with a practical understanding and Hands-On
More informationGBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits
GBRD Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 24 36 48 60 72 62.5/125-OM1 GBRD124 GBRD136 GBRD148 GBRD160
More informationFiretuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red
Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU VERITAS December 2014 OFC-UT-CST
More informationAS/NZS ISO/IEC :2012
AS/NZS ISO/IEC 14763.3:2012 (ISO/IEC 14763-3:2011, MOD) Australian/New Zealand Standard Telecommunications installations Implementation and operation of customer premises cabling Part 3: Testing of optical
More information--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T
Translated English of Chinese Standard: YD/T1447-2013 www.chinesestandard.net Sales@ChineseStandard.net COMMUNICATION INDUSTRY STANDARD OF THE PEOPLE S REPUBLIC OF CHINA YD ICS 33.180.10 M 33 Replacing
More informationSERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Transmission media and optical systems characteristics Optical fibre cables
International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU G.650.3 (03/2008) SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Transmission media and
More informationOWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015
Laser OWL Series Operations Guide Singlemode Light Sources OWL Optical Wavelength Laboratories Operations Guide Laser OWL and Laser OWL HP Singlemode Light Sources Date: October 1, 015 Version.5 Optical
More informationOPTICAL TIME-DOMAIN REFLECTOMETER
Tallinn University of Technology Laboratory exercise 1 of Fiber Optical Communication course OPTICAL TIME-DOMAIN REFLECTOMETER Tallinn 2016 Aim of the laboratory exercise: The aim of this laboratory exercise
More informationFibre optic media options and trends
Fibre optic media options and trends Presented by D Stockton & P Lascelles of Miniflex Ltd, branded as m2fx 23 February 2012 1 Contents Cable constructs Indoor/outdoor LSZH Armouring Micro Bends Singlemode,
More informationGR-326-CORE Singlemode Optical Connectors and Jumper Assemblies
Preface...Preface 1 1. Introduction... 1 1 1.1 Purpose and Scope... 1 1 1.2 Target Audience... 1 2 1.3 Structure and Use of This Document...1 2 1.4 Changes from Issue 2 of GR-326-CORE... 1 3 1.5 Requirements
More informationOptical Fiber Monitor (OFM) Whitebox WB-OFM-1262-DC
Optical Fiber Monitor (OFM) Whitebox WB-OFM-1262-DC www.lumentum.com Data Sheet The Lumentum Optical Fiber Monitor (OFM) Whiteboxes reduce network downtime with automated fault location. Detecting and
More informationMTTplus Modular Test Platform
MTTplus-410 Fiber Optics Test Module 2017 MTTplus Modular Test Platform The Fiber Optics module for the VeEX MTTplus supports a full range of test functions including OTDR, OPM, Light Source and VFL. Geo
More informationFiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling
Hands-On Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling Certification Course Description This Hands-On course is customized to give Technicians the confidence and skills to maintain Fiber
More informationINTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
INTERNATIONAL TELECOMMUNICATION UNION ITU-T L.36 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (10/98) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
More informationCHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES
THE CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES 17th September 2002 Botanical Gardens Birmingham The Way We Were 1GbE and 10GbE OF Categories Channel Design Cleaning SFF Connecting Hardware Testing
More informationLink loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team
Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team INTRODUCTION The OTDR is a very efficient tool for characterizing the elements on
More informationSECTION TESTING OF FIBER OPTIC CABLES
PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction, all materials and equipment incorporated
More informationFTB-7400E Metro/CWDM OTDR METRO/CORE AND CWDM NETWORK FIBER CHARACTERIZATION
METRO/CORE AND CWDM NETWORK FIBER CHARACTERIZATION i OLM R E A D Y GLOBAL PORTABLE FIBER OPTIC TEST EQUIPMENT MARKET LEADERSHIP AWARD High-resolution OTDR covering longer metro distances and ITU-based
More informationGOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M
GOF Indoor and Outdoor Cables Documentation VWL 064.503 Version 1.1 Source Code M GOF Installation Cables Cable matrix / overview Source code M Use Indoor In- / Outdoor Outdoor Type of cable Breakout Mini-
More informationEasy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).
GCDG Multi Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)H(SR)H Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count
More informationHands-On Fiber Optics ISP/OSP - Advanced Combo- Tech
Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech Course Description This Hands-On 3-day course has been customized to provide technicians with a practical understanding of fiber optic theory and fiber
More informationITU-T L.12. Optical fibre joints SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
INTERNATIONAL TELECOMMUNICATION UNION ITU-T L.12 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (05/2000) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
More informationMicrOTDR. Optical Fault Locator. User Manual
Optical Fault Locator Datacom Textron 11001 31 st Place West Everett, WA 98204 TEL: 425-355-0590 Toll Free: 800-468-5557 FAX: 425-290-1600 Internet: www.datacom.textron.com Warranty The MicrOTDR Optical
More informationFujikura-70S Single Fibre Fusion Splicer
Fujikura- Single Fibre Fusion Splicer Features Core-to Core alignment, Dual Axis observation system. World s quickest splicing 6sec. / tube-heating 9sec. Minimal manual operation. Splice in 4 steps. Multi-functional
More informationSumitomo T-39 Core Aligning Fusion Splicer
Sumitomo T-39 Core Aligning Fusion Splicer De Winter Rudy RDeWinter@cnrood.com T-39 Single fibre core aligning splicer New from Sumitomo Electric Industries New features to increase productivity Light
More informationFTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)
TE Connectivity's (TE) FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, TE s FTTX solutions
More information13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION
13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION This specification is property of SEC and subject to change or modification
More informationAV6416 OTDR. Product Overview: Main Features:
AV6416 OTDR Product Overview: AV6416 OTDR is a test instrument designed for FTTx. It s mainly used to measure the physical characteristics of optical fiber & cables, including length, transmission loss
More informationDetection of Solvents using a Distributed Fibre Optic Sensor
Detection of Solvents using a Distributed Fibre Optic Sensor Alistair MacLean, Chris Moran, Walter Johnstone, Brian Culshaw, Dan Marsh, Paul Parker. A fibre optic sensor that is capable of distributed
More informationWhite Paper Fiber optic connections: check and clean first, then connect!
White Paper Fiber optic connections: check and clean first, then connect! How installers ensure the quality of their work Fiber optic connections: check and clean first, then connect! How installers ensure
More informationAdvancing Fiber Optic Connectivity
Advancing Fiber Optic Connectivity Fusion Spice-On Connectors by Brad Everette, America Ilsintech, Dallas, TX and Seung-Min Lee, Ilsintech, Daejeon, South Korea Presentation Overview Advancements in Fiber
More informationM310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)
Designed for Enterprise Network Testing, Troubleshooting and Documentation Features Industry leading TruEvent analysis Short dead zones provide precise testing of closely spaced events Front Panel and
More informationOTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL
OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL Phone: (209) 586-022 (800) 545-022 Fax: (209) 586-026 E-Mail: salessupport@olsontech.com www.olsontech.com OTEB-CO-B (No SNMP) Rev. X7 /7/200 SAFETY WARNINGS
More informationFiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know. David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO
Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO Workshop format The Workshop is going to start with three short lecture style power
More informationFire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.
UL, ULC Approved* Fire Control Panels Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting Features Converts multiple fire alarm communications signals into a single fiber optic
More informationBroadband System - H
Broadband System - H Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz TV TRANSMITTER Headend
More informationNG4access ODF Platform Standard Chassis Installation Manual
NG4access ODF Platform Standard Chassis Installation Manual TECP-90-703 Issue 1 8/2012 24939-A Content Page INTRODUCTION...1 1 PRODUCT DESCRIPTION...2 2 MAIN COMPONENTS...3 3 GROUNDING AND BONDING THE
More informationGUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.
GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 16 24 62.5/125-OM1
More informationMADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments
MADE FOR THE TRADE! professional FIBER OPTIC XL fibertools Series instruments XL fibertools Series Instruments Designed for Fiber Optic Cable Testing. The XL fibertools are designed for the professional
More informationEnsuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis
Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis Experience designing cable and network testers has enabled a breakthrough
More informationFLX380-30x FlexTester OTDR
Features 3rd generation hand-held, all-in-one OTDR, Source, Power Meter, VFL Icon-based LinkMap display with pass/fail for easy network analysis Patented in- or out-of-service testing from a single port
More informationSTATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR FUSION SPLICE AND SPLICE ENCLOSURE FIBER OPTIC CABLE
STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 SPECIFICATIONS FOR FUSION SPLICE AND SPLICE ENCLOSURE FIBER OPTIC CABLE N.J. Specification No. Effective Date: July 1, 2001 New
More information