1 National Fire Protection Association 1 Batterymarch Park, Quincy, MA Phone: Fax: M E M O R A N D U M TO: NEC Code-Making Panel 14 FROM: Kimberly Shea DATE: December 4, 2012 SUBJECT: NFPA 70 CMP-14 ROC TC Letter Ballot (A2013) The ROC letter ballot for NFPA 70 CMP-14 is attached. The ballot is for formally voting on whether or not you concur with the panel s actions on the comments. Reasons must accompany all negative and abstention ballots. Please do not vote negatively because of editorial errors. However, please bring such errors to my attention for action. Please return your ballot as soon as possible but no later than January 11, Ballots may be returned via to panel14@nfpa.org or via fax to You may also mail your ballot to the attention of Kim Shea at NFPA, 1 Batterymarch Park, Quincy, MA The return of ballots is required by the Regulations Governing Committee Projects. Attachments: Comments Letter Ballot

2 Sort Listing Comment # Log# Comm. Action Tech. Comm. Section A NEC-P14 - ( ): R NEC-P14 - ( 500.2, (B)(4), (B)(4), ): R NEC-P14 - ( 500.2, (B)(4), (B)(4), ): APR NEC-P14 - ( 500.2, 504.2, 505.2, 506.2, 513.2, 515.2, and ): R NEC-P14 - ( Combustible Dust ): APR NEC-P14 - ( Combustible Dust ): 14-7 NEC-P R Electrical and Electronic Equipment - ( ): A NEC-P14 - ( 500.4(B), Informational Note 2 ): A NEC-P14 - ( 500.4(B), Informational Note 4 ): A NEC-P14 - ( (B)(1)(7) ): A NEC-P14 - ( (A)(1)(e) ): APR NEC-P14 - ( (A)(1)(e) (New) ): A NEC-P14 - ( (B)(2) ): A NEC-P14 - ( (B)(2), (B)(2)(6)(New) ): A NEC-P14 - ( (E)(1) ): A NEC-P14 - ( (E)(1) ): APP NEC-P14 - ( (B)(2) ): A NEC-P14 - ( (A)(4) ): A NEC-P14 - ( ): A NEC-P14 - ( (B)(6) ): A NEC-P14 - ( (B)(6)(1) ): A NEC-P14 - ( (B) Informational Note 4 ): A NEC-P14 - ( (B)(4) Exception ): R NEC-P14 - ( (B)(4) ): A NEC-P14 - ( (A)(1)(5) ): A NEC-P14 - ( (B)(1)(8) ): A NEC-P14 - ( (B)(2)(6) (New) ): A NEC-P14 - ( (A) ): A NEC-P14 - ( (B)(3) ): R NEC-P14 - ( (B)(4) ): A NEC-P14 - ( ): R NEC-P14 - ( (B)(4) ): A NEC-P14 - ( 504 ): APR NEC-P14 - ( Associated Apparatus ): R NEC-P14 - ( ): A NEC-P14 - ( (B) ): R NEC-P14 - ( and (5) ): A NEC-P14 - ( 505.5(A) ): A NEC-P14 - ( 505.6, Informational Note 2 ): A NEC-P14 - ( 505.7(F) (New) ): Cycle A2013 Page 1

3 Sort Listing Comment # Log# Comm. Action Tech. Comm. Section A NEC-P14 - ( ): A NEC-P14 - ( (B)(1)(g) ): APR NEC-P14 - ( (B)(1)(g) (New) ): APR NEC-P14 - ( (B)(1)(g) (New) ): A NEC-P14 - ( (C)(1)(h) ): A NEC-P14 - ( (B)(1) ): A NEC-P14 - ( , Informational Note ): A NEC-P14 - ( ): R NEC-P14 - ( ): A NEC-P14 - ( ): R NEC-P14 - ( and (5) ): APR NEC-P14 - ( Associated Nonincendive Field Wiring ): R NEC-P14 - ( Combustible Dust ): A NEC-P14 - ( Nonincendive Circuit, Nonincendive ): A NEC-P14 - ( Nonincendive Circuit, Informational Note; ): R NEC-P14 - ( ): R NEC-P14 - ( 506.9(C)(1) ): R NEC-P14 - ( 506.9(C)(2) ): A NEC-P14 - ( (A)(7) ): A NEC-P14 - ( (C)(9) ): R NEC-P14 - ( (D) ): A NEC-P14 - ( ): A NEC-P14 - ( 513.7(F) ): A NEC-P14 - ( (B) ): A NEC-P14 - ( (D)(1) ): A NEC-P14 - ( 516, Informational Note ): A NEC-P14 - ( ): R NEC-P14 - ( Spray Area ): R NEC-P14 - ( Spray Area and (New) ): A NEC-P14 - ( (B)(4) ): A NEC-P14 - ( ): Cycle A2013 Page 2

4 14-1 Log #392 NEC-P14 John L. Simmons, Florida East Coast Electrical JATC 14-3 Revise the text found in Sections 500.2, 504.2, 505.2, 506.2, 513.2, and as follows: Revise the parent text of to include all definitions in Articles that appear in more than one article. A new last sentence is added to make it clear that may have definitions that apply to Articles 505 and 506 but that no other sections of Article 500 apply to 505 or 506 unless they are specifically referenced in the article. This will clarify the intent of CMP14 that Articles 505 and 506 are not a part of the hazardous locations protection methods prescribed in Article 500. Relocate the term associated apparatus from to The term is used in Articles 500, 504, 505 and 506. Include the new term cord connector which was introduced in Proposal 14-11b and accepted by CMP14. Update the standard dates in the informational note for dust-ignitionproof. Change the term dusttight to dusttight (as applied to Hazardous (Classified) Locations). This will in essence remove the conflict between the definition in and Article 100 and it is consistent with the format used in Article 100 to allow two definitions for accessible (accessible (as applied to equipment) and accessible (as applied to wiring methods). Dusttight Informational Note see panel action on Proposal Electrical and Electronic Equipment Informational Note see panel action on Proposal Change the term explosionproof equipment to explosionproof equipment (as applied to Hazardous (Classified) Locations). This will in essence remove the conflict between the definition in and Article 100 and it is consistent with the format used in Article 100 to allow two definitions for accessible (accessible (as applied to equipment) and accessible (as applied to wiring methods). Hermetically Sealed Informational Note see panel action on Proposal Relocate the definition of intrinsically safe apparatus from to The term is found in Articles 500, 503, 504, 505 and 506. Nonincendive Circuit Informational Note see panel action on Proposal Nonincendive Component Informational Note see panel action on Proposal Nonincendive Equipment Informational Note see panel action on Proposal Nonincendive Field Wiring Apparatus Informational Note see panel action on Proposal Delete the Informational Note for Oil Immersion. UL 698 has been withdrawn. Relocate the definition of pressurized and the Informational Note for the definition from to The term is found in Articles 501, 505 and 506. Since the term is also used in Article 326, the phrase as applied to Hazardous (Classified) Locations has been added to make it perfectly clear that this definition is not intended to define the term as used in that article. Relocate the definition of simple apparatus and the Informational Note for the definition from to The term is found in Articles 500, 501, 502, 503, 504, 505 and 506. Create new section Definitions and refer back to This will add clarity to the use of definitions in Articles Create new section Definitions and refer back to This will add clarity to the use of definitions in Articles Create new section Definitions and refer back to This will add clarity to the use of definitions in Articles Create new parent text for The new text will make it perfectly clear that the defined terms in the section apply specifically to Article 504. Delete the definition of associated apparatus" from and relocate it to The term is used in Articles 500, 504, 505 and 506. Delete the control drawing reference to With the proposed restructuring of the definitions in Article it is perfectly clear that defined terms will be found in one of two locations; if the term is used in more than one article and the dot 2 section of the article it appears in, if it is only used in that article. Delete the definition of intrinsically safe apparatus from and relocate it to The term is used in Articles 500, 503, 504, 505, and 506. Update the standard date in the Informational Note for intrinsically safe circuit. Delete the definition of simple apparatus from and relocate it to The term is used in Articles 500, 501, 502, 503, 504, 505, and

5 Revise the parent text for to make it consistent with the new parent text of Delete the definition of combustible gas detection system from The term is defined in and in the current version of the NEC (2008). The term is used Articles 500 and 505. Under the proposed restructure, definitions of terms used in more than one article ( ) are being placed in Delete the definition of electrical and electronic equipment and its Informational Note from The term is defined in and in the current version of the NEC (2008). The term is used Articles 500, 501, 502, 503, 505, and 506. Under the proposed restructure, definitions of terms used in more than one article ( ) are being placed in Revise Informational Note 1 and Note 2 for encapsulation 'm'. See the panel action on Proposal Revise the standard information in the Informational Note for flameproof d. See the panel action on Proposal Revise the standard information in the Informational Note for intrinsic safety 'i'. See the panel action on Proposal Oil Immersion o Informational Note: insert the standard date. Powder Filling q Informational Note: insert the standard date. Revise the standard information in the Informational Note for pressurization p. See the panel action on Proposal Revise the standard information in the Informational Note for type of protection n. See the panel action on Proposal Delete the definition of unclassified locations from The term is defined in and in the current version of the NEC (2008). The term is used Articles 500, 501, 502, 503, 504, 505, 506, 513, 514, and 516. Under the proposed restructure, definitions of terms used in more than one article ( ) are being placed in Revise the parent text for to make it consistent with the new parent text of Delete the definition of associated nonincendive field wiring apparatus from The term is defined in and in the current version of the NEC (2008). The term is used Articles 500, and 506. Under the proposed restructure, definitions of terms used in more than one article ( ) are being placed in Delete the definition of combustible dust from The term is defined in and in the current version of the NEC (2008). The term is used Articles 500, 502, 504, 505, 506, and 516. Under the proposed restructure, definitions of terms used in more than one article ( ) are being placed in Delete the definition of dust-ignitionproof and its Informational Note from The term is defined in and in the current version of the NEC (2008). The term is used Articles 500, 502, and 506. (Other than the definition in the term is only used one other time in 506 and that is in an informational note.) Under the proposed restructure, definitions of terms used in more than one article ( ) are being placed in Delete the definition of dusttight from The term is defined in Article 100 and sections and in the current version of the NEC (2008). The term is used Articles 500, 502, 503, and 506. Under the proposed restructure, definitions of terms used in more than one article ( ) are being placed in Delete the definition of nonincendive circuit and its Informational Note from The term is defined in and in the current version of the NEC (2008). The term is used in Articles 500, 501, 502, 503, and 506. Delete the definition of nonincendive equipment and its Informational Note from The term is defined in and in the current version of the NEC (2008). The term is used in Articles 500, 506, and 516. Delete the definition of nonincendive field wiring from The term is defined in and in the current version of the NEC (2008). The term is used in Articles 500, 501, 502,503, 504, and 506. Delete the definition of nonincendive field wiring apparatus and its Informational Note from The term is defined in and in the current version of the NEC (2008). The term is used in Articles 500, 501, 502, 503, and 506. Delete the definition of pressurized and its Informational Note from The term is defined in and in the current version of the NEC (2008). The term is used in Articles 501, 505 and 506. Change protection by encapsulation md to protection by encapsulation m and revise the standard in the Informational Note No. 1. Revise Informational Note No. 2. See panel action on Proposal Change protection by enclosure td to protection by encapsulation t and revise the standard in the Informational Note No. 1. Add new Informational Note No. 2. See panel action on Proposal Revise the parent text for to make it consistent with the new parent text of Change the term portable equipment to portable equipment (as applied to Article 513). The term portable equipment appears in Articles 250,368, 430, 490, 511, 513, 516, 517, 518, 520, 525, 530, 540, 640, 668, 675, and 680. The term is defined in Articles 513, 520, 530, 640, and 680. This proposed change makes it clear that the definition found in is specific to Article 513. Delete in its entirety. See Proposal

6 Revise the parent text for to make it consistent with the new parent text of A copy of the NEC code text with proposed changes follows: The definitions found in this section are specific to the Hazardous (Classified) Locations found in For purposes of Articles 500 through 504 and Articles 510 through 516 the following definitions apply. No other section of this Article shall apply to Article 505 or 506 unless it is specifically referenced in that article. Apparatus in which the circuits are not necessarily intrinsically safe themselves but that affect the energy in the intrinsically safe circuits and are relied on to maintain intrinsic safety. Associated apparatus may be either of the following: (1) Electrical apparatus that has an alternative-type of protection for use in the appropriate hazardous (classified) location (2) Electrical apparatus not so protected that shall not be used within a hazardous (classified) location Informational Note No. 1: Associated apparatus has identified intrinsically safe connections for intrinsically safe apparatus and also may have connections for nonintrinsically safe apparatus. Informational Note No. 2: An example of associated apparatus is an intrinsic safety barrier, which is a network designed to limit the energy (voltage and current) available to the protected circuit in the hazardous (classified) location, under specified fault conditions. Apparatus in which the circuits are not necessarily nonincendive themselves but that affect the energy in nonincendive field wiring circuits and are relied upon to maintain nonincendive energy levels. Associated nonincendive field wiring apparatus may be either of the following: (1) Electrical apparatus that has an alternative type of protection for use in the appropriate hazardous (classified) location (2) Electrical apparatus not so protected that shall not be used in a hazardous (classified) location Informational Note: Associated nonincendive field wiring apparatus has designated associated nonincendive field wiring apparatus connections for nonincendive field wiring apparatus and may also have connections for other electrical apparatus. Any finely divided solid material that is 420 microns (0.017 in.) or smaller in diameter (material passing a U.S. No. 40 Standard Sieve) and presents a fire or explosion hazard when dispersed and ignited in air. [ 2008] A protection technique utilizing stationary gas detectors in industrial establishments. A drawing or other document provided by the manufacturer of the intrinsically safe or associated apparatus, or of the nonincendive field wiring apparatus or associated nonincendive field wiring apparatus, that details the allowed interconnections between the intrinsically safe and associated apparatus or between the nonincendive field wiring apparatus or associated nonincendive field wiring apparatus. A fitting intended to terminate a cord to a box or similar device and reduce the strain at points of termination and may include an explosionproof, a dust-ignition proof, or a flameproof seal. Equipment enclosed in a manner that excludes dusts and does not permit arcs, sparks, or heat otherwise generated or liberated inside of the enclosure to cause ignition of exterior accumulations or atmospheric suspensions of a specified dust on or in the vicinity of the enclosure. Informational Note: For further information on dustignitionproof enclosures, see Type 9 enclosure in ANSI/NEMA ,, and ANSI/UL ,. Enclosures constructed so that dust will not enter under specified test conditions. Informational Note: See ANSI/ISA ,. ANSI/ISA , Materials, fittings, devices, appliances, and the like that are part of, or in connection with, an electrical installation. Informational Note: Portable or transportable equipment having self-contained power supplies, such as battery-operated equipment, could potentially become an ignition source in hazardous (classified) locations. See ISA-RP , ANSI/ISA ,. Equipment enclosed in a case that is capable of withstanding an explosion of a specified gas or vapor that may occur within it and of preventing the ignition of 3

7 a specified gas or vapor surrounding the enclosure by sparks, flashes, or explosion of the gas or vapor within, and that operates at such an external temperature that a surrounding flammable atmosphere will not be ignited thereby. Informational Note: For further information, see ANSI/UL ,. Equipment sealed against the entrance of an external atmosphere where the seal is made by fusion, for example, soldering, brazing, welding, or the fusion of glass to metal. Informational Note: For further information, see ANSI/ISA ,. ANSI/ISA , Apparatus in which all the circuits are intrinsically safe. A circuit, other than field wiring, in which any arc or thermal effect produced under intended operating conditions of the equipment, is not capable, under specified test conditions, of igniting the flammable gas air, vapor air, or dust air mixture. Informational Note: Conditions are described in ANSI/ISA ,. ANSI/ISA , A component having contacts for making or breaking an incendive circuit and the contacting mechanism is constructed so that the component is incapable of igniting the specified flammable gas air or vapor air mixture. The housing of a nonincendive component is not intended to exclude the flammable atmosphere or contain an explosion. Informational Note: For further information, see ANSI/ISA , ANSI/ISA , Equipment having electrical/electronic circuitry that is incapable, under normal operating conditions, of causing ignition of a specified flammable gas air, vapor air, or dust air mixture due to arcing or thermal means. Informational Note: For further information, see ANSI/ISA ,. ANSI/ISA , Wiring that enters or leaves an equipment enclosure and, under normal operating conditions of the equipment, is not capable, due to arcing or thermal effects, of igniting the flammable gas air, vapor air, or dust air mixture. Normal operation includes opening, shorting, or grounding the field wiring. Apparatus intended to be connected to nonincendive field wiring. Informational Note: For further information, see ANSI/ISA ,. ANSI/ISA , Electrical equipment immersed in a protective liquid in such a way that an explosive atmosphere that may be above the liquid or outside the enclosure cannot be ignited. Informational Note: For further information, see ANSI/UL ,. The process of supplying an enclosure with a protective gas with or without continuous flow at sufficient pressure to prevent the entrance of combustible dust or ignitable fibers/flyings. Informational Note: For further information, see ANSI/NFPA , The process of (1) purging, supplying an enclosure with a protective gas at a sufficient flow and positive pressure to reduce the concentration of any flammable gas or vapor initially present to an acceptable level; and (2) pressurization, supplying an enclosure with a protective gas with or without continuous flow at sufficient pressure to prevent the entrance of a flammable gas or vapor, a combustible dust, or an ignitable fiber. Informational Note: For further information, see ANSI/NFPA ,. An electrical component or combination of components of simple construction with well defined 4

8 electrical parameters that does not generate more than 1.5 volts, 100 milliamps, and 25 milliwatts, or a passive component that does not dissipate more than 1.3 watts and is compatible with the intrinsic safety of the circuit in which it is used. Informational Note: The following apparatus are examples of simple apparatus: a) Passive components, for example, switches, junction boxes, resistance temperature devices, and simple semiconductor devices such as LEDs b) Sources of stored energy consisting of single components in simple circuits with well-defined parameters, for example, capacitors or inductors, whose values are considered when determining the overall safety of the system c) Sources of generated energy, for example, thermocouples and photocells, which do not generate more than 1.5 V, 100 ma milliamps, and 25 mw milliwatts Locations determined to be neither Class I, Division 1; Class I, Division 2; Class I, Zone 0; Class I, Zone 1; Class I, Zone 2; Class II, Division 1; Class II, Division 2; Class III, Division 1; Class III, Division 2; Zone 20; Zone 21; Zone 22; or any combination thereof. See See See Definitions found in this section are specific to this Article. Apparatus in which the circuits are not necessarily intrinsically safe themselves but that affect the energy in the intrinsically safe circuits and are relied on to maintain intrinsic safety. Associated apparatus may be either of the following: (1) Electrical apparatus that has an alternative-type protection for use in the appropriate hazardous (classified) location (2) Electrical apparatus not so protected that shall not be used within a hazardous (classified) location Informational Note No. 1: Associated apparatus has identified intrinsically safe connections for intrinsically safe apparatus and also may have connections for nonintrinsically safe apparatus. Informational Note No. 2: An example of associated apparatus is an intrinsic safety barrier, which is a network designed to limit the energy (voltage and current) available to the protected circuit in the hazardous (classified) location, under specified fault conditions. See the definition in Intrinsically safe circuits in which the possible interconnections have not been evaluated and identified as intrinsically safe. Apparatus in which all the circuits are intrinsically safe. A circuit in which any spark or thermal effect is incapable of causing ignition of a mixture of flammable or combustible material in air under prescribed test conditions. Informational Note: Test conditions are described in ANSI/UL ,. An assembly of interconnected intrinsically safe apparatus, associated apparatus, and interconnecting cables, in that those parts of the system that may be used in hazardous (classified) locations are intrinsically safe circuits. Informational Note: An intrinsically safe system may include more than one intrinsically safe circuit. An electrical component or combination of components of simple construction with well defined electrical parameters that does not generate more than 1.5 volts, 100 milliamps, and 25 milliwatts, or a passive component that does not dissipate more than 1.3 watts and is compatible with the intrinsic safety of the circuit in which it is used. Informational Note: The following apparatus are examples of simple apparatus: d) Passive components, for example, switches, junction boxes, resistance temperature devices, and simple semiconductor devices such as LEDs e) Sources of stored energy consisting of single components in simple circuits with well-defined parameters, for example, capacitors or inductors, whose values are considered when determining the overall safety of the system f) Sources of generated energy, for example, thermocouples and photocells, which do not generate more than 1.5 V, 100 ma, and 25 mw For purposes of this article, the following definitions apply. Definitions found in this section are specific to this Article. A protection technique utilizing stationary gas detectors in industrial establishments. Materials, fittings, devices, appliances, and the like that are part of, or in connection with, an electrical installation. Informational Note: Portable or transportable equipment having self-contained power supplies, such as battery 5

9 operated equipment, could potentially become an ignition source in hazardous (classified) locations. Type of protection where electrical parts that could ignite an explosive atmosphere by either sparking or heating are enclosed in a compound in such a way that this explosive atmosphere cannot be ignited. Informational Note No. 1: See ANSI/ISA ( )-2009, ; IEC , and ANSI/UL , -2009, Explosive atmospheres - Part 18: Equipment protection by encapsulation m. Informational Note No. 2: Encapsulation is designated type of protection ma for use in Zone 0 locations. Encapsulation is designated type of protection m or mb for use in Zone 1 locations. Encapsulation is designated type of protection mc for use in Zone 2 locations. Type of protection where the enclosure will withstand an internal explosion of a flammable mixture that has penetrated into the interior, without suffering damage and without causing ignition, through any joints or structural openings in the enclosure, of an external explosive gas atmosphere consisting of one or more of the gases or vapors for which it is designed. Informational Note: See ANSI/ISA ( )-2008, ; ANSI/ISA ( ), and ANSI/UL , Type of protection applied to electrical equipment that does not produce arcs or sparks in normal service and under specified abnormal conditions, in which additional measures are applied so as to give increased security against the possibility of excessive temperatures and of the occurrence of arcs and sparks. Informational Note: See ANSI/ISA ( ) , ; and ANSI/UL , Type of protection where any spark or thermal effect is incapable of causing ignition of a mixture of flammable or combustible material in air under prescribed test conditions. Informational Note No. 1: See ANSI/UL , ; ANSI/ISA ( )-2009, ; ANSI/ISA ( ), and ANSI/UL , Informational Note No. 2: Intrinsic safety is designated type of protection ia for use in Zone 0 locations. Intrinsic safety is designated type of protection ib for use in Zone 1 locations. Intrinsic safety is designated type of protection ic for use in Zone 2 locations. Informational Note No. 3: Intrinsically safe associated apparatus, designated by [ia], [ib], or [ic], is connected to intrinsically safe apparatus ( ia, ib, or ic, respectively) but is located outside the hazardous (classified) location unless also protected by another type of protection (such as flameproof). Type of protection where electrical equipment is immersed in a protective liquid in such a way that an explosive atmosphere that may be above the liquid or outside the enclosure cannot be ignited. Informational Note: See ANSI/ISA ( )-2009, ; and ANSI/UL , Type of protection where electrical parts capable of igniting an explosive atmosphere are fixed in position and completely surrounded by filling material (glass or quartz powder) to prevent the ignition of an external explosive atmosphere. Informational Note: See ANSI/ISA ( )-2009, ; and ANSI/UL , Type of protection for electrical equipment that uses the technique of guarding against the ingress of the external atmosphere, which may be explosive, into an enclosure by maintaining a protective gas therein at a pressure above that of the external atmosphere. Informational Note: See ANSI/ISA ( )-2004, ; ANSI/ISA ( ), and IEC ,. Type of protection where electrical equipment, in normal operation, is not capable of igniting a 6

10 surrounding explosive gas atmosphere and a fault capable of causing ignition is not likely to occur. Informational Note: See ANSI/UL , ; and ANSI/ISA ( )-2008, ANSI/ISA ( )-2009, Locations determined to be neither Class I, Division 1; Class I, Division 2; Class I, Zone 0; Zone 1; Zone 2; Class II, Division 1; Class II, Division 2; Class III, Division 1; Class III, Division 2; or any combination thereof. For purposes of this article, the following definitions apply. Definitions found in this section are specific to this Article. Apparatus in which the circuits are not necessarily nonincendive themselves but that affects the energy in nonincendive field wiring circuits and are relied upon to maintain nonincendive energy levels. Associated nonincendive field wiring apparatus may be either of the following: (1) Electrical apparatus that has an alternative type of protection for use in the appropriate hazardous (classified) location (2) Electrical apparatus not so protected that shall not be used in a hazardous (classified) location Informational Note: Associated nonincendive field wiring apparatus has designated associated nonincendive field wiring apparatus connections for nonincendive field wiring apparatus and may also have connections for other electrical apparatus. Any finely divided solid material that is 420 microns (0.017 in.) or smaller in diameter (material passing a U.S. No. 40 Standard Sieve) and presents a fire or explosion hazard when dispersed and ignited in air. [ 3.3.3] Equipment enclosed in a manner that excludes dusts and does not permit arcs, sparks, or heat otherwise generated or liberated inside of the enclosure to cause ignition of exterior accumulations or atmospheric suspensions of a specified dust on or in the vicinity of the enclosure. Informational Note: For further information on dustignitionproof enclosures, see Type 9 enclosure in ANSI/NEMA ,, and ANSI/UL ,. Enclosures constructed so that dust will not enter under specified test conditions. A circuit, other than field wiring, in which any arc or thermal effect produced under intended operating conditions of the equipment, is not capable, under specified test conditions, of igniting the flammable gas air, vapor air, or dust air mixture. Informational Note: Conditions are described in ANSI/ISA ,. Equipment having electrical/electronic circuitry that is incapable, under normal operating conditions, of causing ignition of a specified flammable gas air, vapor air, or dust air mixture due to arcing or thermal means. Informational Note: Conditions are described in ANSI/ISA , Wiring that enters or leaves an equipment enclosure and, under normal operating conditions of the equipment, is not capable, due to arcing or thermal effects, of igniting the flammable gas air, vapor air, or dust air mixture. Normal operation includes opening, shorting, or grounding the field wiring. Apparatus intended to be connected to nonincendive field wiring. Informational Note: Conditions are described in ANSI/ISA , The process of supplying an enclosure with a protective gas with or without continuous flow at sufficient pressure to prevent the entrance of combustible dust or ignitable fibers/flyings. Informational Note: For further information, see ANSI/NFPA , Type of protection where electrical parts that could cause ignition of a mixture of combustible dust or fibers/flyings in air are protected by enclosing them in a compound in such a way that the explosive atmosphere cannot be ignited. Informational Note No. 1: For additional information, see ANSI/ISA ( )-2006, ANSI/ISA ( )-2009,, ANSI/UL ,, and ANSI/ISA ( )-2011, 7

11 . Informational Note No. 2: Encapsulation is designated level of protection mad or ma for use in Zone 20 locations. Encapsulation is designated level of protection mbd or mb for use in Zone 21 locations. Encapsulation is designated type of protection mc for use in Zone 22 locations. Type of protection for explosive dust atmospheres where electrical apparatus is provided with an enclosure providing dust ingress protection and a means to limit surface temperatures. Informational Note 1: For additional information, see ANSI/ISA ( ) , ANSI/ISA ( )-2006,, and ANSI/ISA ( ) , Informational Note No. 2: Protection by Enclosure is designated level of protection ta for use in Zone 20 locations. Protection by Enclosure is designated level of protection tb or td for use in Zone 21 locations. Protection by Enclosure is designated level of protection tc or td for use in Zone 22 locations. Type of protection where any spark or thermal effect is incapable of causing ignition of a mixture of combustible dust, fibers, or flyings in air under prescribed test conditions. Informational Note: For additional information, see ANSI/ISA ( ), Type of protection that guards against the ingress of a mixture of combustible dust or fibers/flyings in air into an enclosure containing electrical equipment by providing and maintaining a protective gas atmosphere inside the enclosure at a pressure above that of the external atmosphere. Informational Note: For additional information, see ANSI/ISA ( ),. An area where combustible dust or ignitable fibers/flyings are present continuously or for long periods of time in quantities sufficient to be hazardous, as classified by 506.5(B)(1). An area where combustible dust or ignitable fibers/flyings are likely to exist occasionally under normal operation in quantities sufficient to be hazardous, as classified by 506.5(B)(2). An area where combustible dust or ignitable fibers/flyings are not likely to occur under normal operation in quantities sufficient to be hazardous, as classified by 506.5(B)(3). For the purpose of this article, the following definitions shall apply. Definitions found in this section are specific to this Article. An aircraft hangar constructed for the express purpose of spray/coating/dipping applications and provided with dedicated ventilation supply and exhaust. Equipment with electrical components suitable to be moved only with mechanical aids or is provided with wheels for movement by person(s) or powered devices. Equipment with electrical components suitable to be moved by a single person without mechanical aids. That portion of a property where liquids are received by tank vessel, pipelines, tank car, or tank vehicle and are stored or blended in bulk for the purpose of distributing such liquids by tank vessel, pipeline, tank car, tank vehicle, portable tank, or container. [ ] Informational Note: For further information, see NFPA ,. For the purpose of this article, the following definitions shall apply. Definitions found in this section are specific to this Article. Normally, locations outside of buildings or localized operations within a larger room or space. Such are normally provided with some local vapor extraction/ventilation system. In automated operations, the area limits shall be the maximum area in the direct path of spray operations. In manual operations, the area limits shall be the maximum area of spray when aimed at 180 degrees to the application surface. An enclosure or insert within a larger room used for spray/coating/dipping applications. A spray booth may be fully enclosed or have open front or face and may include separate conveyor entrance and exit. The spray booth is provided with a dedicated ventilation exhaust but may draw supply air from the larger room or have a dedicated air supply. A purposefully enclosed room built for spray/coating/dipping applications provided with dedicated ventilation supply and exhaust. Normally the room is configured to house the item to be painted, providing reasonable access around the item/process. Depending on the size of the item being painted, such rooms may actually be the entire building or the major portion thereof. This comment is the product of the task group request by the TCC (reference Proposal 14-3). The 8

12 group was appointed by the panel chair Robert Jones. The task group chair is John Simmons. Panel members are: William Lawrence, Edward Briesch, Jack Jamison, Mark Goodman, Larry Burns, and David Wechsler. The suggested changes resolve the issues surrounding any duplicate or conflicting definitions within the purview of CMP14. The revisions that are made involve relocating any definition used in more than one article ( ) to Definitions specific to any article remain in the article where they are used. Definitions found in Articles that are found in articles other than have been revised by changing the defined term (i.e. Dusttight (as applied to Hazardous (Classified) Locations)). The reorganization of the Article definitions will add clarity to the code. Revise the text found in Sections 500.2, 504.2, 505.2, 506.2, 513.2, and as follows: ***Insert Include for CMP-14-1 Here*** Also, change the edition date of NFPA 496 from 2008 to 2013 wherever NFPA 496 is referenced in Chapter 5. CMP-14 has reorganized the definitions in Article 500 through 516, as directed by the Correlating Committee. CMP-14 notes that the amended text reflects other actions taken by the panel, as reflected elsewhere in the ROC. These include the actions on Comments 14-4, 14-6, 14-34, 14-51, 14-52, 14-54, 14-55, and

13 500.2 Definitions. The definitions found in this section are specific to the Hazardous (Classified) Locations found in For purposes of Articles 500 through 504 and Articles 510 through 516 the following definitions apply. No other section of this Article shall apply to Article 505 or 506 unless it is specifically referenced in that article. Associated Apparatus. Apparatus in which the circuits are not necessarily intrinsically safe themselves but that affect the energy in the intrinsically safe circuits and are relied on to maintain intrinsic safety. Associated Such apparatus may be either are one of the following: (1) Electrical apparatus that has an alternative-type of protection for use in the appropriate hazardous (classified) location (2) Electrical apparatus not so protected that shall not be used within a hazardous (classified) location Informational Note No. 1: Associated apparatus has identified intrinsically safe connections for intrinsically safe apparatus and also may have connections for nonintrinsically safe apparatus. Informational Note No. 2: An example of associated apparatus is an intrinsic safety barrier, which is a network designed to limit the energy (voltage and current) available to the protected circuit in the hazardous (classified) location, under specified fault conditions. Associated Nonincendive Field Wiring Apparatus. Apparatus in which the circuits are not necessarily nonincendive themselves but that affect the energy in nonincendive field wiring circuits and are relied upon to maintain nonincendive energy levels. Associated nonincendive field wiring Such apparatus are one may be either of the following: (1) Electrical apparatus that has an alternative type of protection for use in the appropriate hazardous (classified) location (2) Electrical apparatus not so protected that shall not be used in a hazardous (classified) location Informational Note: Associated nonincendive field wiring apparatus has designated associated nonincendive field wiring apparatus connections for nonincendive field wiring apparatus and may also have connections for other electrical apparatus. Combustible Dust. Any finely divided solid material that is 420 microns (0.017 in.) or smaller in diameter (material passing a U.S. No. 40 Standard Sieve) and presents a fire or explosion hazard when dispersed and ignited in air. [499, 2008] Combustible Dust. Dust particles that are 500 microns or smaller (material passing a U.S. No. 35 Standard Sieve as defined in ASTM E 11, Standard Specification for Wire Cloth and Sieves for Testing Purposes) and present a fire or explosion hazard when dispersed and ignited in air. Informational Note: See ASTM E 1226, Standard Test Method for Explosibility of Dust Clouds, or ISO , Explosion protection systems - Part 1: Determination of explosion indices of combustible dusts in air, for procedures for determining the explosibility of dusts. Combustible Gas Detection System. A protection technique utilizing stationary gas detectors in industrial establishments. Control Drawing. A drawing or other document provided by the manufacturer of the intrinsically safe or associated apparatus, or of the nonincendive field wiring apparatus or associated nonincendive field wiring apparatus, that details the allowed interconnections between the intrinsically safe and associated apparatus or between the nonincendive field wiring apparatus or associated nonincendive field wiring apparatus. Cord Connector. Cord Connector. A fitting intended to terminate a cord to a box or similar device and reduce the strain at points of termination and may include an explosionproof, a dust-ignition proof, or a flameproof seal. 70_Log 392_Panel Action_ROC_A2013

14 Dust-Ignitionproof. Equipment enclosed in a manner that excludes dusts and does not permit arcs, sparks, or heat otherwise generated or liberated inside of the enclosure to cause ignition of exterior accumulations or atmospheric suspensions of a specified dust on or in the vicinity of the enclosure. Informational Note: For further information on dustignitionproof enclosures, see Type 9 enclosure in ANSI/NEMA , Enclosures for Electrical Equipment, and ANSI/UL , Explosionproof and Dust-Ignitionproof Electrical Equipment for Hazardous (Classified) Locations. Dusttight (as applied to Hazardous (Classified) Locations). Enclosures constructed so that dust will not enter under specified test conditions. Informational Note: See ANSI/ISA , Nonincendive Electrical Equipment for Use in Class I and II, Division 2, and Class III, Divisions 1 and 2 Hazardous (Classified) Locations. ANSI/ISA , Nonincendive Electrical Equipment for Use in Class I and II, Division 2, and Class III, Divisions 1 and 2 Hazardous (Classified) Locations. Electrical and Electronic Equipment. Materials, fittings, devices, appliances, and the like that are part of, or in connection with, an electrical installation. Informational Note: Portable or transportable equipment having self-contained power supplies, such as battery-operated equipment, could potentially become an ignition source in hazardous (classified) locations. See ISA-RP , Recommended Practice for Portable Electronic Products Suitable for Use in Class I and II, Division 2, Zone 2 and Class III, Division 1 and 2 Hazardous (Classified) Locations. ANSI/ISA , Standard for Portable Electronic Products Suitable for Use in Class I and II, Division 2, Zone 2 and Class III, Division 1 and 2 Hazardous (Classified) Locations. Explosionproof Equipment (as applied to Hazardous (Classified) Locations). Equipment enclosed in a case that is capable of withstanding an explosion of a specified gas or vapor that may occur within it and of preventing the ignition of a specified gas or vapor surrounding the enclosure by sparks, flashes, or explosion of the gas or vapor within, and that operates at such an external temperature that a surrounding flammable atmosphere will not be ignited thereby. Informational Note: For further information, see ANSI/UL , Explosion-Proof and Dust- Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations. Hermetically Sealed. Equipment sealed against the entrance of an external atmosphere where the seal is made by fusion, for example, soldering, brazing, welding, or the fusion of glass to metal. Informational Note: For further information, see ANSI/ISA , Nonincendive Electrical Equipment for Use in Class I and II, Division 2, and Class III, Division 1 and 2 Hazardous (Classified) Locations. ANSI/ISA , Nonincendive Electrical Equipment for Use in Class I and II, Division 2, and Class III, Divisions 1 and 2 Hazardous (Classified) Locations. Intrinsically Safe Apparatus. Apparatus in which all the circuits are intrinsically safe. Nonincendive Circuit. A circuit, other than field wiring, in which any arc or thermal effect produced under intended operating conditions of the equipment, is not capable, under specified test conditions, of igniting the flammable gas air, vapor air, or dust air mixture. Informational Note: Conditions are described in ANSI/ISA , Nonincendive Electrical Equipment for Use in Class I and II, Division 2, and Class III, Divisions 1 and 2 Hazardous (Classified) Locations. ANSI/ISA , Nonincendive Electrical Equipment for Use in Class I and II, Division 2, and Class III, Divisions 1 and 2 Hazardous (Classified) Locations. Nonincendive Component. A component having contacts for making or breaking an incendive circuit and the contacting mechanism is constructed so that the component is incapable of igniting the specified flammable gas air or vapor air mixture. The housing of a nonincendive component is not intended to exclude the flammable atmosphere or contain an explosion. 70_Log 392_Panel Action_ROC_A2013

15 Informational Note: For further information, see ANSI/ISA , Nonincendive Electrical Equipment for Use in Class I and II, Division 2, and Class III, Divisions 1 and 2 Hazardous (Classified) Locations. ANSI/ISA , Nonincendive Electrical Equipment for Use in Class I and II, Division 2, and Class III, Divisions 1 and 2 Hazardous (Classified) Locations. Nonincendive Equipment. Equipment having electrical/electronic circuitry that is incapable, under normal operating conditions, of causing ignition of a specified flammable gas air, vapor air, or dust air mixture due to arcing or thermal means. Informational Note: For further information, see ANSI/ISA , Nonincendive Electrical Equipment for Use in Class I and II, Division 2, and Class III, Divisions 1 and 2 Hazardous (Classified) Locations. ANSI/ISA , Nonincendive Electrical Equipment for Use in Class I and II, Division 2, and Class III, Divisions 1 and 2 Hazardous (Classified) Locations. Nonincendive Field Wiring. Wiring that enters or leaves an equipment enclosure and, under normal operating conditions of the equipment, is not capable, due to arcing or thermal effects, of igniting the flammable gas air, vapor air, or dust air mixture. Normal operation includes opening, shorting, or grounding the field wiring. Nonincendive Field Wiring Apparatus. Apparatus intended to be connected to nonincendive field wiring. Informational Note: For further information, see ANSI/ISA , Nonincendive Electrical Equipment for Use in Class I and II, Division 2, and Class III, Divisions 1 and 2 Hazardous (Classified) Locations. ANSI/ISA , Nonincendive Electrical Equipment for Use in Class I and II, Division 2, and Class III, Divisions 1 and 2 Hazardous (Classified) Locations. Oil Immersion. Electrical equipment immersed in a protective liquid in such a way that an explosive atmosphere that may be above the liquid or outside the enclosure cannot be ignited. Informational Note: For further information, see ANSI/UL , Industrial Control Equipment for Use in Hazardous (Classified) Locations. Pressurized (as applied to Hazardous (Classified) Locations). The process of supplying an enclosure with a protective gas with or without continuous flow at sufficient pressure to prevent the entrance of combustible dust or ignitable fibers/flyings. Informational Note: For further information, see ANSI/NFPA , Standard for Purged and Pressurized Enclosures for Electrical Equipment. Purged and Pressurized. The process of (1) purging, supplying an enclosure with a protective gas at a sufficient flow and positive pressure to reduce the concentration of any flammable gas or vapor initially present to an acceptable level; and (2) pressurization, supplying an enclosure with a protective gas with or without continuous flow at sufficient pressure to prevent the entrance of a flammable gas or vapor, a combustible dust, or an ignitable fiber. Informational Note: For further information, see ANSI/NFPA , Purged and Pressurized Enclosures for Electrical Equipment. Simple Apparatus. An electrical component or combination of components of simple construction with well defined electrical parameters that does not generate more than 1.5 volts, 100 milliamps, and 25 milliwatts, or a passive component that does not dissipate more than 1.3 watts and is compatible with the intrinsic safety of the circuit in which it is used. Informational Note: The following apparatus are examples of simple apparatus: a) Passive components, for example, switches, junction boxes, resistance temperature devices, and simple semiconductor devices such as LEDs 70_Log 392_Panel Action_ROC_A2013

AGENDA. NEC Code-Making Panel 14. Report on Comment Meeting. November 28-December 1, Redondo Beach, CA

AGENDA. NEC Code-Making Panel 14. Report on Comment Meeting. November 28-December 1, Redondo Beach, CA National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org AGENDA NEC Code-Making Panel 14 Report on Comment Meeting November 28-December

More information

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: NEC Code-Making Panel 14 From: Kimberly Shea, Project Administrator

More information

Report on Proposals June 2013 NFPA 70

Report on Proposals June 2013 NFPA 70 14-1 Log #1170m NEC-P14 Russell LeBlanc, The Peterson School In articles 90 through 830, if the wording is not already there, then add the words (or other structure(s)) after the word BUILDING(S) wherever

More information

UL HAZARDOUS LOCATIONS SERVICES

UL HAZARDOUS LOCATIONS SERVICES UL HAZARDOUS LOCATIONS SERVICES The international preference in hazardous locations certification for over 100 years ul.com/hazloc Explosive Gas Atmospheres Class I Division S Includes flammable gases,

More information

Report on Proposals June 2013 NFPA 70

Report on Proposals June 2013 NFPA 70 14-1 Log #1170m NEC-P14 Russell LeBlanc, The Peterson School In articles 90 through 830, if the wording is not already there, then add the words (or other structure(s)) after the word BUILDING(S) wherever

More information

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates Note: While this material was originally prepared for presentation in February 1999, it has been updated to reflect the evolving technical requirements now applicable as of April 2003. UL Topic III Converting

More information

AGENDA. NEC Code-Making Panel 14. Report on Proposal Meeting. January 16-21, Hilton Head, SC

AGENDA. NEC Code-Making Panel 14. Report on Proposal Meeting. January 16-21, Hilton Head, SC National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org AGENDA NEC Code-Making Panel 14 Report on Proposal Meeting January 16-21,

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Merchant Vessels

More information

A Guide to Safe Electronic Weighing in Hazardous Locations

A Guide to Safe Electronic Weighing in Hazardous Locations SMART SOLUTIONS FOR DEMANDING INDUSTRIES Solutions for Process Weighing and Force Measurement Handbook TC0013 1. Hazardous Locations... 2 2. Methods of Protection... 3 3. Approval/Listing of Equipment...

More information

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle)

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle) M E M O R A N D U M TO: FROM: NFPA Technical Committee on Alternative Approaches to Life Safety Linda MacKay DATE: December 28, 2010 SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle) The ROP letter

More information

Overview of Hazardous Locations as They Relate to Solenoid Valves

Overview of Hazardous Locations as They Relate to Solenoid Valves Overview of Hazardous Locations as They Relate to Solenoid Valves Defined: Hazardous Location - "where fire or explosion hazards may exist due to flammable gases or vapors, flammable liquids, combustible

More information

Installation guide for hazardous areas

Installation guide for hazardous areas Installation guide for hazardous areas This installation guide should not be used as the controlling document for the installation of devices in a hazardous area. This guide is NOT A CONTROL DRAWING. Any

More information

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems Products Solutions Services CT287 Hazardous Area Classifications and Protection Systems Slide 1 Topics covered Types of Hazardous Area classifications with focus on North America Types of hazardous protection

More information

First Revision No. 1-NFPA [ Chapter 2 ]

First Revision No. 1-NFPA [ Chapter 2 ] First Revision No. 1-NFPA 499-2014 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this recommended practice

More information

Committee on NFPA 85

Committee on NFPA 85 Committee on NFPA 85 M E M O R A N D U M TO: FROM: NFPA Technical Committee on Single Burner Boilers Patti Mucci, Technical Assistant II DATE: August 5, 2009 SUBJECT: NFPA ROP Letter Ballot The ROP letter

More information

Introduction to Hazardous Electrical Location Classifications

Introduction to Hazardous Electrical Location Classifications Introduction to Hazardous Electrical Location Classifications Introduction In North America the target audience for this white paper and the electrical code classification ratings for various types of

More information

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt Airo Wireless Intrinsically Safe White Paper Written By: David Schmitt Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection certification for safe operation with electronic

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Hot Work Operations

More information

Approval Standard for Electric Equipment for use in Hazardous (Classified) Locations General Requirements

Approval Standard for Electric Equipment for use in Hazardous (Classified) Locations General Requirements Approval Standard for Electric Equipment for use in Hazardous (Classified) Locations General Requirements Class Number 3600 November 1998 2002 FM Approvals LLC. All rights reserved. Foreword FM Approvals

More information

Guide for hazardous areas

Guide for hazardous areas Guide for hazardous areas 1 Hazardous areas definitions 2 Gas and dust s 3 Temperature classifications 4 Common flammable gases, vapours and dust types 5 Protection concepts ATEX and IECEx 6 Protection

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The

More information

CODE DIGEST CODE DIGEST. Solutions.Worldwide.TM Crouse-Hinds is a registered trademark of Cooper Industries, Inc. COOPER CROUSE-HINDS

CODE DIGEST CODE DIGEST. Solutions.Worldwide.TM Crouse-Hinds is a registered trademark of Cooper Industries, Inc. COOPER CROUSE-HINDS COOPER CROUSE-HINDS COOPER CROUSE-HINDS CODE DIGEST CODE DIGEST Article 500-516 of the National Electrical Code with product recommendations for use in hazardous (classified) areas. Distributed by: For

More information

Report on Proposals F2007 Copyright, NFPA NFPA 499 Report of the Committee on

Report on Proposals F2007 Copyright, NFPA NFPA 499 Report of the Committee on Report on Proposals F2007 Copyright, NFPA NFPA 499 Report of the Committee on This list represents the membership at the time the Committee was balloted on the text of this edition. Since that time, changes

More information

Approval Standard for Electrical Equipment for Use in Hazardous (Classified) Locations - General Requirements

Approval Standard for Electrical Equipment for Use in Hazardous (Classified) Locations - General Requirements Approval Standard for Electrical Equipment for Use in Hazardous (Classified) Locations - General Requirements Class Number 3600 December 2011 2011 FM Approvals LLC. All rights reserved. Foreword The FM

More information

August Process Industry Practices Electrical. PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification

August Process Industry Practices Electrical. PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification Electrical Engineering Guide for Determining Electrical Area Classification PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice

More information

An Urgent Bulletin from CSA Group

An Urgent Bulletin from CSA Group An Urgent Bulletin from CSA Group Hazardous Locations Products No. 28 (Supersedes Electrical Certification Notice No. 544A) Date: January 3, 2018 See Attachment 1 for Effective Dates. See Attachment 1

More information

S T R I T T & P R I E B E I N C.

S T R I T T & P R I E B E I N C. Equipment Enclosure Comparisons Type of Enclosure European - Area of use Designation Standard IEC - Area of use Designation Standard USA - Area of use Designation Standard Flameproof Enclosure An enclosure

More information

Smoke detection in hazardous areas:

Smoke detection in hazardous areas: WHITE PAPER Smoke detection in hazardous areas: What you need to know Smoke detection in hazardous areas requires detectors that operate effectively and safely in explosive environments. Having the correct

More information

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016)

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Solvent Extraction Plants

More information

Committee on NFPA 51A

Committee on NFPA 51A Committee on M E M O R A N D U M TO: FROM: NFPA Technical Committee on Industrial and Medical Gases Patti Mucci, Administrative Assistant DATE: May 6, 2010 SUBJECT: ROC Letter Ballot The ROC letter ballot

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60

More information

Numerical Standards Listing

Numerical Standards Listing Numerical Standards Listing ISA-RP2.1-1978 - Manometer Tables ISA-5.1-1984 (R1992) - Instrumentation Symbols and Identification (Formerly ANSI/ISA-5.1-1984 [R1992]) ISA-5.2-1976 (R1992) - Binary Logic

More information

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals Selecting a Safe Tank Gauging Product Understanding Hazardous Area Definitions for Equipment Approvals Hazardous Area Approvals A Worldwide Requirement There are many environmental considerations within

More information

CLASS I LOCATIONS ZONE CLASSIFICATION

CLASS I LOCATIONS ZONE CLASSIFICATION HAZARDOUS (CLASSIFIED) LOCATIONS Hazardous locations are those locations where the risk of a fire or explosion may exist due to the presence of flammable gases or vapors, flammable liquids, combustible

More information

PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification

PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification September 2016 Electrical PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry

More information

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS ENCLOSURES. Select equipment enclosures to provide the following: To protect facility personnel from coming in contact with live parts.

More information

Electrical Area Classification 101 An Introduction to Area Classification the Basics IEEE Houston CED

Electrical Area Classification 101 An Introduction to Area Classification the Basics IEEE Houston CED Electrical Area Classification 101 An Introduction to Area Classification the Basics IEEE Houston CED October 3rd, 2017 Vincent W. Wedelich, PE, MBA Project Manager Associate Electrical Engineer 10 Years

More information

Public Input No. 3-NFPA [ Chapter 2 ]

Public Input No. 3-NFPA [ Chapter 2 ] Public Input No. 3-NFPA 655-2014 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard and shall be considered

More information

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors Drive Technology \ Drive Automation \ System Integration \ Services *23511257_0817* Inquiry Forms for Explosion-Proof Gearmotors Edition 08/2017 23511257/EN SEW-EURODRIVE Driving the world Inquiry forms

More information

M EM O RA N D UM. NFPA 652 First Draft Correlating Committee FINAL Ballot Results (A2018)

M EM O RA N D UM. NFPA 652 First Draft Correlating Committee FINAL Ballot Results (A2018) M EM O RA N D UM TO: FROM: DATE: SUBJECT: Correlating Committee on Combustible Dusts Yiu Lee, Project Administrator January 27, 2017 NFPA 652 First Draft Correlating Committee FINAL Ballot Results (A2018)

More information

Articles , & National Electrical Code Review & Application Guide

Articles , & National Electrical Code Review & Application Guide Articles 500-506, 510-511 & 513-516 2011 National Electrical Code Review & Application Guide Established in 1913, Killark has become a global provider of harsh and hazardous location equipment. The Killark

More information

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot M E M O R A N D U M TO: FROM: NFPA Technical Committee on Building Service and Fire Protection Equipment Gregory Harrington, P.E., Staff Liaison DATE: October 1, 2009 SUBJECT: NFPA 5000 A2011 ROP Letter

More information

TECHNICAL COMMITTEE ON MANUFACTURE OF ORGANIC COATINGS First Draft Meeting Agenda March 19, :00 AM - 5:00 PM EST Web/Teleconference Meeting

TECHNICAL COMMITTEE ON MANUFACTURE OF ORGANIC COATINGS First Draft Meeting Agenda March 19, :00 AM - 5:00 PM EST Web/Teleconference Meeting TECHNICAL COMMITTEE ON MANUFACTURE OF ORGANIC COATINGS First Draft Meeting Agenda March 19, 2014 9:00 AM - 5:00 PM EST Web/Teleconference Meeting 1. Welcome. George Seuss, Chair 2. Introductions and Update

More information

Beamex. Calibration White Paper. Calibration in hazardous areas

Beamex. Calibration White Paper.   Calibration in hazardous areas Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous

More information

ATEX, NOMENCLATURE AND CODING

ATEX, NOMENCLATURE AND CODING Technical Notes ATEX, NOMENCLATURE AND CODING The intent of this technical note is approach to the user to the ATEX normative. For this we will begin defining, what is an explosive atmosphere, what are

More information

Installing Foundation Fieldbus H1 in Hazardous Areas. Presented By: Jim Peterson Sr. Applications Engineer MTL/USA

Installing Foundation Fieldbus H1 in Hazardous Areas. Presented By: Jim Peterson Sr. Applications Engineer MTL/USA Installing Foundation Fieldbus H1 in Hazardous Areas Presented By: Jim Peterson Sr. Applications Engineer MTL/USA (Divisions) (Zones) Zone 0 ia) Intrinsically Safe Class I Division 1 Explosion Proof Purged

More information

Beamex Calibration White Paper. Calibration in hazardous areas

Beamex Calibration White Paper.  Calibration in hazardous areas Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous

More information

NEC 2017 Changes and Their Effect Upon the ICT Industry

NEC 2017 Changes and Their Effect Upon the ICT Industry NEC 2017 Changes and Their Effect Upon the ICT Industry Today s Presenters John Kacperski, RCDD, OSP, CDT Chair of BICSI Standards BICSI Representative on NFPA 70-CMP 16 Richard S. Anderson, RCDD, CDT,

More information

Portable Equipment. Equipment with electrical components suitable to be moved by a single person without mechanical aids.

Portable Equipment. Equipment with electrical components suitable to be moved by a single person without mechanical aids. Portable Equipment. Equipment with electrical components suitable to be moved by a single person without mechanical aids. Power Outlet. An enclosed assembly that may include receptacles, circuit breakers,

More information

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials Fire Preven4on Officers Associa4on of Bri4sh Columbia 2013 Annual Seminar Kelowna, Bri4sh Columbia May 9, 2013 NFPA 33 Scope

More information

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas

More information

Specifying Temperature Sensors for Hazardous Areas

Specifying Temperature Sensors for Hazardous Areas Specifying Temperature Sensors for Hazardous Areas The manufacture of petroleum products, paint, and many chemicals can lead to the release of flammable gases. When these gases accumulate in enclosed areas,

More information

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or

More information

Continuing Education, For UDC Electrical Inspectors, Commercial Electrical Inspectors, Master Electricians and Journeyman Electricians.

Continuing Education, For UDC Electrical Inspectors, Commercial Electrical Inspectors, Master Electricians and Journeyman Electricians. Continuing Education, For UDC Electrical Inspectors, Commercial Electrical Inspectors, Master Electricians and Journeyman Electricians. The following test is for Continuing Education Credits for the abovementioned

More information

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas Intrinsic Safety Intrinsically Safe Solutions Accurate Weighing in Hazardous Areas Accidents in hazardous areas can have dramatic consequences for businesses in terms of both human life and profit. Intrinsically

More information

Today's world of increasing

Today's world of increasing Applying Intrinsic Safety Today's world of increasing process control in potentially explosive atmospheres has forced designers and engineers to specify more efficient and effective ways of protecting

More information

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU GENERAL The accidental ignition of an atmosphere containing a large quantity of gas, vapour, mists and/or dust may cause an explosion. Specific

More information

ATEX, NOMENCLATURE AND CODING

ATEX, NOMENCLATURE AND CODING ATEX, NOMENCLATURE AND CODING The intent of this technical note is approach to the user to the ATEX normative. For this we will begin defining, what is an explosive atmosphere, what are ATEX, as well as

More information

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here. A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here Introduction Potentially Explosive Atmospheres exist where there is a risk

More information

Special Occupancy Requirements

Special Occupancy Requirements Special Occupancy Requirements CHAPTER 2 0 AVIATION FACILITIES CHAPTER 2 1 DRY CLEANING CHAPTER 2 2 COMBUSTIBLE DUST-PRODUCING OPERATIONS Special Occupancies The objective of this module is to make the

More information

Page 1 of 19 Committee Input No. 14-NFPA 33-2013 [ Global Input ] Type your content here... Supplemental Information File Name IndoorDraftforCI.docx Description This committee input would be added to new

More information

Committee Input No. 60-NFPA [ Sections , ]

Committee Input No. 60-NFPA [ Sections , ] Page 1 of 15 Committee Input No. 60-NFPA 34-2013 [ Sections 3.3.7.1, 3.3.7.2 ] Sections 3.3.7.1, 3.3.7.2 3.3.7.1 Combustible Liquid. A Any liquid that has a closed-cup flash point at or above 100 F (37.8

More information

Meeting NFPA standards for

Meeting NFPA standards for 24 Fire safety Meeting NFPA standards for flame, smoke and gas detection Fire is one of the most critical hazards in any built environment, and industrial processes and facilities that involve volatile

More information

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM 1 of 213 10/20/2016 11:02 AM Committee Input No. 2505-NFPA 72-2016 [ Global Input ] Change the term visible to visual where appropriate Submitter Information Verification Submitter Full Name: SIG-NAS Organization:

More information

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169 7471 Phone: 617 770 3000 Fax: 617 770 0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Furnishings

More information

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification Public Input No. 1-NFPA 36-2013 [ Global Input ] Revise the document to eliminate the use of "Exception" text. The use of "Exception" text is inconsistent with the Manual of Style. Exception text should

More information

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas Page 1 of 5 Title Install fixed gas detection apparatus in hazardous areas Level 4 Credits 2 Purpose This unit standard covers the installation, calibration, and response checking of fixed gas detection

More information

SERIES & NO. SMI SUBJECT: SAFE CONSIDERATIONS FOR AN APPLICATION OF SPECIAL ELECTRICAL SYSTEMS

SERIES & NO. SMI SUBJECT: SAFE CONSIDERATIONS FOR AN APPLICATION OF SPECIAL ELECTRICAL SYSTEMS 1 of 4 SUBJECT: SAFE CONSIDERATIONS FOR AN APPLICATION OF I. PURPOSE To provide basic guidelines for identifying electrical systems required for special installations. II. REFERENCES National Electric

More information

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement 1 of 7 3/4/2016 12:02 PM Second Revision No. 5-NFPA 56-2016 [ Section No. 1.1.2 ] 1.1.2 Nonapplication of Standard. This standard shall not apply to the following items: (1)* Piping systems covered by

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 2792948 Issued to: Siemens Canada Limited 1954 Technology Drive Peterborough, ON K9J 7B1 Canada Attention: Mr. Lee Rogers The products listed below are eligible

More information

MEMORANDUM. SUBJ: NFPA 72 Proposed TIA No FINAL CC BALLOT RESULTS

MEMORANDUM. SUBJ: NFPA 72 Proposed TIA No FINAL CC BALLOT RESULTS National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: NFPA Correlating Committee on Signaling Systems for

More information

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY Cell Phones Smartphones PDA integrating people, products and processes Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2185148 (217005) Issued to: RAE Systems, Inc. 3775 North First St San Jose, California 95134 USA Attention: James Pan The products listed below are eligible to bear

More information

INTRODUCTION TO DUSTS AND THEIR EXPLOSIVE PROPERTIES

INTRODUCTION TO DUSTS AND THEIR EXPLOSIVE PROPERTIES INTRODUCTION TO DUSTS AND THEIR EXPLOSIVE PROPERTIES Olof Bekker Pr. Eng. BSc. Eng. BML S.MSAIEE, M.NACE Engineering Manager, Electrical and Facilities DUST EXPLOSION! 1 DEFINITION Dust consists of small

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: NEC Code-Making Panel 3 FROM: Kimberly Shea DATE:

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: NEC Code-Making Panel 15 FROM: Kimberly Shea DATE:

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: Correlating Committee on Combustible Dusts Susan

More information

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT Olof Bekker Pr. Eng. BSc. Eng. BML S.MSAIEE, M.NACE Engineering Manager, Electrical COMMITMENT

More information

Fire Alarm System Accessories

Fire Alarm System Accessories UL, ULC Approved* Fire Alarm System Accessories Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer isolated barrier

More information

Numerical Standards Listing

Numerical Standards Listing ISA-RP2.1-1978 - Manometer Tables Numerical Standards Listing ISA-5.1-1984 (R1992) - Instrumentation Symbols and Identification (Formerly ANSI/ISA-5.1-1984 [R1992]) ISA-5.2-1976 (R1992) - Binary Logic

More information

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts Guy R. Colonna, PE Division Manager, NFPA Combustible Dust Symposium Detroit, MI September 20, 2011 1 Objectives

More information

Understanding. Combustible Dust Hazards: Basic Measures to Ensure the Safety of Combustible Dust Handling Operations

Understanding. Combustible Dust Hazards: Basic Measures to Ensure the Safety of Combustible Dust Handling Operations Understanding Combustible Dust Hazards: Basic Measures to Ensure the Safety of Combustible Dust Handling Operations Michigan Safety Conference April 11, 2017 Mike Snyder PE CSP CFPS Vice President Organizational

More information

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma, User s Manual YTA Series Temperature Transmitters [Style: S3] Manual Change No. 10-008 Please use the attached sheets in the following manuals when the product is with /KU2 option and EN60000 Series based

More information

ORDER CODES T-642B 76T82- D10 77T-662C. CODE DESCRIPTION 38 3/16 6HN 1/2" x 1/2" NPT steel hex nipple 1" "E" length 48 1/4 68 3/8

ORDER CODES T-642B 76T82- D10 77T-662C. CODE DESCRIPTION 38 3/16 6HN 1/2 x 1/2 NPT steel hex nipple 1 E length 48 1/4 68 3/8 Explosion-Proof, Fixed-Element RTDs are made for use in U.S. and Canadian hazardous areas. They are designed to extinguish flames inside the device, eliminating the potential for ignition of flammable

More information

M E M O R A N D U M. NFPA Technical Committee on Wood and Cellulosic Materials Processing

M E M O R A N D U M. NFPA Technical Committee on Wood and Cellulosic Materials Processing National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Wood and Cellulosic

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate IECEx

More information

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES CHAPTER 18 SEMICONDUCTOR FABRICATION FACILITIES SECTION FC 1801 GENERAL 1801.1 Scope. This chapter shall govern the design, installation, operation and maintenance of semiconductor fabrication facilities

More information

Understanding Hazardous Locations Concepts

Understanding Hazardous Locations Concepts Gas Well Deliquification Workshop Sheraton Hotel, February 23 26, 2014 Understanding Hazardous Locations Concepts Mark Scantlebury, P. Eng., BASc President and CEO Extreme Telematics Corp. Disclaimer The

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Mercantile and

More information

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input of 280 2/6/2015 12:06 PM Public Input No. 1-NFPA 58-2013 [ Global Input ] NOTE: This public input originates from Tentative Interim Amendment 58-14-1 (TIA 1079) issued by the Standards Council on August

More information

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: NEC Code-Making Panel 17 From: Kimberly Shea, Project Administrator

More information

[ TECHNOLOGY ] and does this definition affect a burner.

[ TECHNOLOGY ] and does this definition affect a burner. [ TECHNOLOGY ] JBD-11,500-G type burner for natural gas ATEX, EExd Zone 2. For combined cycle power plant in Riga Latvia. Aitor Fernández Project Engineer Automation Department Head afernandez@emcombustion.es

More information

National Fire Protection Association

National Fire Protection Association National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M (AMENDMENT) TO: FROM: Technical Committee on Mercantile

More information

Official Journal of the European Union

Official Journal of the European Union C 20/16 27.1.2009 Commission communication in the framework of the implementation of the Directive 94/9/EC of the European Parliament and the Council on the approximation of the laws of the Member States

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: NEC Code-Making Panel 12 FROM: Kimberly Shea DATE:

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: NEC Code-Making Panel 2 FROM: Kimberly Shea, Administrator,

More information

Numerical Standards Listing

Numerical Standards Listing ISA-RP2.1-1978 - Manometer Tables Numerical Standards Listing ANSI/ISA-5.1-1984 (R1992) - Instrumentation Symbols and Identification ANSI/ISA-5.2-1976 (R1992) - Binary Logic Diagrams for Process Operations

More information

First Revision No. 15-NFPA [ Chapter 2 ]

First Revision No. 15-NFPA [ Chapter 2 ] Page 1 of 28 First Revision No. 15-NFPA 91-2013 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard

More information

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The entrepreneurial basis of the R. STAHL Technology Group follows a long tradition. The product range is aimed at specialised

More information