Ribbon Breakout Kit Installation Instructions

Size: px
Start display at page:

Download "Ribbon Breakout Kit Installation Instructions"

Transcription

1 Ribbon Breakout Kit Installation Instructions LOOSE BUFFER TUBE RIBBON KIT BLK-RLBT- (SEE PAGE 3) CENTRAL OVAL TUBE RIBBON KIT BLK-RCT- (SEE PAGE 12) RIBBON CENTRAL TUBE KIT BLK-RCT- (SEE PAGE 20) A RIBBON IFC CABLE KIT BLK-RIFC- (SEE PAGE 27) INTRODUCTION This manual contains installation instructions for the following fiber ribbon breakout kits: Loose Buffer Tube Ribbon Kit (BLK-RLBT), Central Oval Tube Ribbon Kit (BLK-RCT), Ribbon Central Tube Kit (BLK-RCT), and the Ribbon IFC Cable Kit (BLK-RIFC) Rev B Page Tyco Electronics Corporation. All Rights Reserved.

2 Contents Page 1 LOOSE BUFFER TUBE RIBBON KIT INSTALLATION CENTRAL OVAL TUBE RIBBON KIT (BLK-RCT) RIBBON CENTRAL TUBE KIT (BLK-RCT) RIBBON IFC CABLE KIT (BLK-RIFC) CUSTOMER INFORMATION AND ASSISTANCE Revision History ISSUE DATE REASON FOR CHANGE Issue 1 5/04 Original Issue 2 5/11 Change name of kit from Blocking Kit to Breakout Kit and rebrand with new logo. Trademark Information TE Connectivity, TE (logo), Tyco Electronics, ADC, and ADC Telecommunications are trademarks. Admonishments Important safety admonishments are used throughout this manual to warn of possible hazards to persons or equipment. An admonishment identifies a possible hazard and then explains what may happen if the hazard is not avoided. The admonishments in the form of Dangers, Warnings, and Cautions must be followed at all times. These warnings are flagged by use of the triangular alert icon (seen below), and are listed in descending order of severity of injury or damage and likelihood of occurrence. Danger: Danger is used to indicate the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Warning: Warning is used to indicate the presence of a hazard that can cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Caution: Caution is used to indicate the presence of a hazard that will or can cause minor personal injury or property damage if the hazard is not avoided. Page , Tyco Electronics Corporation. All Rights Reserved.

3 ADCP Issue 2, May LOOSE BUFFER TUBE RIBBON KIT INSTALLATION Figure 1 shows the Loose Buffer Tube Ribbon Kit (BLK-RLBT) catalog scheme. LOOSE BUFFER TUBE RIBBON KIT BLK-RLBT- NUMBER OF PROTECTIVE TUBES PER SUBUNIT NUMBER OF SUBUNITS PROTECTIVE TUBING CUTTING TOOL 0=NOT INCLUDED C=INCLUDED A Figure 1. Loose Buffer Tube Ribbon Kit Catalog Scheme Page Tyco Electronics Corporation. All Rights Reserved.

4 1. Strip the outer cable jacket to expose the inner subunits (Figure 2). Note: Subunit and ribbon fiber lengths are determined by equipment specifications. A maximum of 5 meters (16.4 feet) of bare fiber can be fed through an oval tube. 2. Strip subunit jackets to expose ribbon fiber (Figure 2). Cut strength member as shown. RIBBON FIBER SUBUNITS (6) OUTER CABLE JACKET LENGTH DETERMINED BY EQUIPMENT SPECIFICATIONS 6-IN. MINIMUM OUTER CABLE JACKET STRIP OUTER CABLE JACKET BACK TO EXPOSE SUBUNITS. SUBUNIT BREAKOUT LENGTH IS DETERMINED BY EQUIPMENT SPECIFICATIONS. OUTER CABLE JACKET STRIPPED BACK SUBUNITS (6) SUBUNITS (6) STRENGTH MEMBER CUT STRENGTH MEMBER BACK, AS SHOWN STRIP SUBUNIT JACKETS BACK TO EXPOSE RIBBON FIBERS 6-IN. (15.2 CM) MIN. NOTE: SUBUNIT LENGTH MUST BE AT LEAST 6-IN. (15.2 CM) TO ALLOW FOR FANOUT CLIPS A RIBBON FIBER (12 OR 24 FIBERS PER SUBUNIT) Figure 2. Strip Outer Cable Jacket and Subunit Jackets Page , Tyco Electronics Corporation. All Rights Reserved.

5 ADCP Issue 2, May Place adhesive strip tape (provided) around entire end of each subunit (Figure 3). Note: One subunit shown for clarity. PLACE ADHESIVE STRIP TAPE AROUND ENTIRE END OF EACH SUBUNIT A NOTE: ONE SUBUNIT SHOWN FOR CLARITY Figure 3. Place Tape on End of Each Subunit Page Tyco Electronics Corporation. All Rights Reserved.

6 4. Clean the moisture blocking gel off each ribbon fiber according to local practice (Figure 4). Caution: Do not use alcohol packets (provided) for cleaning ribbon fibers, use the alcohol packets to lubricate the ribbon fibers before inserting them into the oval tubes. 5. After cleaning ribbon fibers, use alcohol wipes (one per oval tube) to lubricate the top and bottom of the ribbon fibers before inserting ribbon fibers into oval tube (Figure 4).! CAUTION: DO NOT USE ALCOHOL PACKETS (PROVIDED WITH KIT) FOR CLEANING RIBBON FIBERS. USE ALCOHOL PACKETS (ONE PER OVAL TUBE) TO LUBRICATE THE RIBBON FIBERS BEFORE INSERTING THEM INTO OVAL TUBES. CLEAN MOISTURE BLOCKING GEL OFF EACH RIBBON FIBER ACCORDING TO LOCAL PRACTICE. ONE RIBBON FIBER. REPEAT CLEANING PROCEDURE FOR EACH RIBBON FIBER A Figure 4. Clean and Lubricate Ribbon Fibers Page , Tyco Electronics Corporation. All Rights Reserved.

7 ADCP Issue 2, May Carefully feed ribbon fibers through oval tubes (Figure 5). Note: Feed up to six, 12-fiber ribbons into each tube at the same time. Note: The oval tubes and retainer plate are shipped pre-assembled as shown. NOTE: OVAL TUBES AND RETAINER PLATE ARE SHIPPING PRE-ASSEMBLED RETAINER PLATE OVAL TUBE (4) CAREFULLY, FEED RIBBON FIBERS THROUGH OVAL TUBES (UP TO SIX, 12-FIBER RIBBONS PER TUBE)! WHEN FEEDING RIBBON FIBERS INTO TUBES, FEED UP TO SIX, 12 FIBER RIBBONS INTO THEIR RESPECTIVE TUBE AT THE SAME TIME A Figure 5. Insert Ribbon Fibers into Oval Tubes Page Tyco Electronics Corporation. All Rights Reserved.

8 7. Insert cable ties (2) up through holes in bottom of base (Figure 6). BASE INSERT CABLE TIES UP THROUGH HOLES IN BASE CABLE TIE A Figure 6. Insert Cable Tie into Base Page , Tyco Electronics Corporation. All Rights Reserved.

9 ADCP Issue 2, May Align face plate with face plate pocket in base and place subunit assembly into base (Figure 7). Adjust subunit either forward or backward to the location shown in the lower view. Note: Subunit assembly includes subunit, ribbon fibers, face plate and oval tubes. FACE PLATE ALIGN FACE PLATE WITH FACE PLATE POCKET AND PLACE SUBUNIT ASSEMBLY INTO BASE FACE PLATE POCKET BASE SUBUNIT POSITION BEFORE ADJUSTING FORWARD ADJUST THE LOCATION OF THE SUBUNIT FORWARD (OR BACKWARD) IF NECESSARY SUBUNIT POSITION AFTER ADUSTING FORWARD MAKE SURE SUBUNIT IS ALIGNED IN BASE AS SHOWN. SUBUNIT IN CORRECT POSITION A Figure 7. Place Subunit Assembly into Fanout Base Page Tyco Electronics Corporation. All Rights Reserved.

10 9. Route the cable tie around the subunit and down through the other side of the base (Figure 8). Cinch the cable tie and cut off excess portion. ROUTE CABLE TIE AROUND SUBUNIT AND DOWN THROUGH OPPOSITE SIDE OF BASE. CINCH CABLE TIES CUT EXCESS CABLE TIE A Figure 8. Install Cable Ties (2) Page , Tyco Electronics Corporation. All Rights Reserved.

11 ADCP Issue 2, May Secure cover onto base using two screws (Figure 9). SECURE COVER WITH SCREWS (2) INSTALL COVER COVER SECURED A Figure 9. Install Top Cover onto Base Page Tyco Electronics Corporation. All Rights Reserved.

12 2 CENTRAL OVAL TUBE RIBBON KIT (BLK-RCT) Figure 10 shows the catalog scheme for the Central Oval Tube Ribbon Kit. ADC recommends using the Central Oval Tube Ribbon Kit for kits up to 12 protective tubes. For kits greater than 12 protective tubes, use the larger Ribbon Central Tube Kit (BLK-RCT). See Section 3, Ribbon Central Tube Kit (BLK-RCT).! ADC RECOMMENDS USING CENTRAL OVAL TUBE RIBBON KIT FOR UP TO 12 PROTECTIVE TUBES. USE RIBBON CENTRAL TUBE KIT (SEE SECTION 3) WHEN MORE THAN 12 PROTECTIVE TUBES ARE NEEDED. CENTRAL OVAL TUBE RIBBON KIT BLK-RCT- RIBBON TYPE A B </=12 FIBER 24 FIBER NUMBER OF PROTECTIVE TUBES CENTRAL TUBE OUTSIDE DIAMETER B C D E.200"-.325" (5.0mm - 8.2mm).325"-.425" (8.2mm mm).425"-.600" (10.8mm mm).600"-.800" (15.2mm mm) PROTECTIVE TUBING CUTTING TOOL 0=NOT INCLUDED C=INCLUDED A USE RIBBON CENTRAL TUBE KIT FOR MORE THAN 12 PROTECTIVE TUBES (RECOMMENDED) (SEE SECTION 3) Figure 10. Central Oval Tube Ribbon Kit Catalog Scheme Page , Tyco Electronics Corporation. All Rights Reserved.

13 ADCP Issue 2, May Strip outer cable jacket to expose inner central tube (Figure 11). Trim strength members flush with outer cable jacket. Clean residue from outside of central tube to prevent slippage when block is attached. 2. Strip central tube back 1.5-inches (min) to expose bare ribbons. (Ribbon fiber length determined by equipment specifications.) Note: A maximum of 5 meters (16.4 feet) of bare fiber can be fed through an oval tube. RIBBON FIBER CENTRAL TUBE (NOT PROVIDED) OUTER CABLE JACKET (NOT PROVIDED) LENGTH DETERMINED BY EQUIPMENT SPECIFICATIONS 1.5-IN. MINIMUM OUTER CABLE JACKET STRIP OUTER CABLE JACKET BACK TO EXPOSE CENTRAL TUBE OUTER CABLE JACKET STRIPPED BACK CENTRAL TUBE TRIM STRENGTH MEMBER FLUSH WITH OUTER CABLE JACKET 1.5-IN. (3.81 CM) A STRIP CENTRAL TUBE BACK NOTE: RIBBON FIBER LENGTH DETERMINED BY EQUIPMENT SPECIFICATIONS CLEAN RESIDUE FROM OUTER CENTRAL TUBE TO PREVENT SLIPAGE RIBBON FIBERS 12 OR 24 FIBERS Figure 11. Breakout Ribbon Fibers Page Tyco Electronics Corporation. All Rights Reserved.

14 3. Place black strip tape (provided) around the entire end of the central tube (See Figure 12). Make sure to position tape so rubber grommet will cover tape A PLACE BLACK STRIP TAPE (PROVIDED) AROUND ENTIRE END OF CENTRAL TUBE. MAKE SURE TO LOCATE TAPE SO RUBBER GROMMET (PROVIDED) WILL COVER TAPE SUFACE. Figure 12. Place Adhesive Tape around End of Central Tube 4. Select the thickest rubber grommet (supplied) that will fit between central tube and flare tube (Figure 13). Position over central tube making sure to cover tape surface. Note: This snug fit is critical when attaching flare tube to central tube. MAKE SURE GROMMET (PROVIDED) WILL COVER TAPE SUFACE A! SELECT THE THICKEST GROMMET SUPPLIED THAT WILL FIT BETWEEN CENTRAL TUBE AND FLARE TUBE. Figure 13. Install Rubber Grommet Page , Tyco Electronics Corporation. All Rights Reserved.

15 ADCP Issue 2, May Carefully insert central tube into flare tube (provided). Align grommet opening with slot in end of flare tube (Figure 14). CAREFULLY SLIDE FLARE TUBE OVER RIBBON FIBERS, CENTRAL TUBE AND RUBBER GROMMET. ALIGN SLOT IN FLARE TUBE WITH CUT IN GROMMET. CENTRAL TUBE FLARE TUBE ALIGNED NOT ALIGNED FLARE TUBE INSTALLED IN CORRECT POSITION FLARE TUBE NOT INSTALLED IN CORRECT POSITION A Figure 14. Install Flare Tube Page Tyco Electronics Corporation. All Rights Reserved.

16 6. Place hose clamp (provided) over flare tube and tighten with screwdriver (Figure 15). Do not over tighten. INSTALL HOSE CLAMP OVER FLARE TUBE IN THE LOCATION SHOWN WITH DASHED LINES TIGHTEN HOSE CLAMP USING SCREWDRIVER (DO NOT OVER TIGHTEN)! DO NOT OVER TIGHTEN A Figure 15. Install Hose Clamp Page , Tyco Electronics Corporation. All Rights Reserved.

17 ADCP Issue 2, May Clean the moisture blocking gel off each ribbon fiber according to local practice. 8. After cleaning ribbon fibers, use alcohol wipes (one per oval tube) to lubricate the top and bottom of the ribbon fibers before inserting ribbon fibers into oval tube (Figure 16). Caution: Do not use alcohol packets (provided) for cleaning ribbon fibers, use the alcohol packets to lubricate the ribbon fibers before inserting them into the oval tubes.! CAUTION: DO NOT USE ALCOHOL PACKETS (PROVIDED WITH KIT) FOR CLEANING RIBBON FIBERS. USE ALCOHOL PACKETS (ONE PER OVAL TUBE) TO LUBRICATE THE RIBBON FIBERS BEFORE INSERTING THEM INTO OVAL TUBES. CLEAN MOISTURE BLOCKING GEL OFF EACH RIBBON FIBER ACCORDING TO LOCAL PRACTICE. ONE RIBBON FIBER. REPEAT CLEANING PROCEDURE FOR EACH RIBBON FIBER A Figure 16. Clean and Lubricate Ribbon Fibers Page Tyco Electronics Corporation. All Rights Reserved.

18 9. Carefully feed ribbon fibers through oval tubes (Figure 17). Caution: Care must be taken to ensure ribbon fibers are not twisted or bent. 10. Align retainer plate key with flare tube slot and snap into place (Figure 17). Note: Feed up to six, 12-fiber ribbons into each tube at the same time. Note: The oval tubes and retainer plate are shipped pre-assembled as shown. CAREFULLY, FEED RIBBON FIBERS THROUGH OVAL TUBES INSERTING ALL FIBERS INTO RESPECTIVE TUBE AT THE SAME TIME. (UP TO SIX, 12-FIBER RIBBONS PER TUBE)! NOTE: OVAL TUBES AND RETAINER PLATE ARE SHIPPED PRE-ASSEMBLED ALIGN RETAINER PLATE KEY WITH SLOT IN FLARE TUBE FLARE TUBE RETAINER PLATE SNAP RETAINER PLATE INTO FLARE TUBE. RETAINER PLATE WILL NOT ROTATE AFTER SNAPPED INTO FLARE TUBE A! CARE MUST BE TAKEN TO ENSURE RIBBON FIBER UNITS ARE NOT TWISTED OR BENT. Figure 17. Feed Ribbon Fibers into Oval Tubes, Snap Retainer Plate into Flare Tube Page , Tyco Electronics Corporation. All Rights Reserved.

19 ADCP Issue 2, May (OPTIONAL) Fill flare tube with water-blocking sealant (Figure 18). Use numbered labels (provided) and mark ends of oval tubes, for reference. (OPTIONAL) CAREFULLY FILL FLARE TUBE WITH WATER-BLOCKING SEALANT A (OPTIONAL) NUMBER TUBES WITH LABELS PROVIDED Figure 18. (Optional) Fill Flare Tube with Water-Blocking Sealant, and Number Tube Ends Page Tyco Electronics Corporation. All Rights Reserved.

20 3 RIBBON CENTRAL TUBE KIT (BLK-RCT) Figure 19 shows the catalog scheme for the Ribbon Central Tube Kit. ADC recommends using the Ribbon Central Tube Kit for kits with more than 12-protective tubes. For kits less than 12 protective tubes, use the Central Oval Tube Ribbon Kit (BLK-RCT). See Section 2, Central Oval Tube Ribbon Kit (BLK-RCT).! ADC RECOMMENDS USING RIBBON CENTRAL TUBE KIT WHEN MORE THAN 12 PROTECTIVE TUBES ARE NEEDED. USE CENTRAL OVAL TUBE RIBBON KIT (SEE SECTION 2) FOR UP TO 12 PROTECTIVE TUBES. RIBBON CENTRAL TUBE KIT BLK-RCT- RIBBON TYPE A B </=12 FIBER 24 FIBER USE CENTRAL OVAL TUBE RIBBON KIT FOR UP TO 12 PROTECTIVE TUBES (RECOMMENDED) (SEE SECTION 2) NUMBER OF PROTECTIVE TUBES CENTRAL TUBE OUTSIDE DIAMETER B C D E.200"-.325" (5.0mm - 8.2mm).325"-.425" (8.2mm mm).425"-.600" (10.8mm mm).600"-.800" (15.2mm mm) PROTECTIVE TUBING CUTTING TOOL 0=NOT INCLUDED C=INCLUDED A Figure 19. Ribbon Central Tube Kit (BLK-RCT) Catalog Scheme Page , Tyco Electronics Corporation. All Rights Reserved.

21 ADCP Issue 2, May Strip outer cable jacket to expose inner central tube. Trim strength members flush with outer cable jacket. Clean residue from outside of central tube to prevent slippage when clamping kit is attached (Figure 20). Note: A maximum of 5 meters (16.4 feet) of bare fiber can be fed through an oval tube. RIBBON FIBERS CENTRAL TUBE OUTER CABLE JACKET LENGTH DETERMINED BY EQUIPMENT SPECIFICATIONS 1.25-IN. (3.18 CM) STRENGTH MEMBER OUTER CABLE JACKET TRIM STRENGTH MEMBER FLUSH WITH OUTER CABLE JACKET STRIP OUTER CABLE JACKET BACK TO EXPOSE CENTRAL TUBE OUTER CABLE JACKET STRIPPED BACK CENTRAL TUBE 1.25-IN. (3.18 CM) A STRIP CENTRAL TUBE BACK NOTE: RIBBON FIBER LENGTH DETERMINED BY EQUIPMENT SPECIFICATIONS RIBBON FIBERS 12 OR 24 FIBERS CLEAN RESIDUE FROM OUTER CENTRAL TUBE Figure 20. Breakout Ribbon Fibers Page Tyco Electronics Corporation. All Rights Reserved.

22 2. Clean moisture blocking gel off each ribbon fiber according to local practice (Figure 21). Caution: Do not use alcohol wipes (provided) for cleaning ribbon fibers. 3. After cleaning ribbon fibers, use alcohol wipes (one per oval tube) to lubricate the top and bottom of the ribbon fibers before inserting ribbon fibers into oval tube. Note: Top and bottom ribbon fibers should be moist with alcohol when inserting them into oval tubes.! CAUTION: DO NOT USE ALCOHOL PACKETS (PROVIDED WITH KIT) FOR CLEANING RIBBON FIBERS. USE ALCOHOL PACKETS (ONE PER OVAL TUBE) TO LUBRICATE THE RIBBON FIBERS BEFORE INSERTING THEM INTO OVAL TUBES. CLEAN MOISTURE BLOCKING GEL OFF EACH RIBBON FIBER ACCORDING TO LOCAL PRACTICE. ONE RIBBON FIBER. REPEAT CLEANING PROCEDURE FOR EACH RIBBON FIBER A Figure 21. Clean Moisture Blocking Gel off Ribbon Fibers Page , Tyco Electronics Corporation. All Rights Reserved.

23 ADCP Issue 2, May Insert ribbon fibers (up to six, 12-fiber ribbons per tube at the same time) into each oval tube (Figure 22). INSERT RIBBON FIBERS (UP TO SIX, 12-FIBER RIBBONS PER OVAL TUBE) INTO EACH OVAL TUBE. BASE A OVAL TUBES (12 OVAL TUBES SHOWN FOR REFERENCE) RIBBON FIBERS (UP TO SIX, 12-FIBER RIBBONS PER OVAL TUBE) Figure 22. Insert Ribbon Fibers into Oval Tubes 5. Continue to carefully guide ribbon fiber into oval tubing while moving base toward the central tube (Figure 23). CENTRAL TUBE CONTINUE TO GUIDE RIBBON FIBERS INTO TUBE WHILE MOVING BASE TOWARD THE CENTRAL TUBE BASE A Figure 23. Guide Base toward Central Tube Page Tyco Electronics Corporation. All Rights Reserved.

24 6. Position clamp kit yoke around central tube on base. Make sure central tube protrudes 0.25-inches (0.64 cm) beyond yoke. Insert clamp kit plate and screws (one piece) up through holes in base and yoke. (Figure 24). BASE POSITION YOKE ON BASE UNDER CENTRAL TUBE CENTRAL TUBE 0.25-IN. (0.64 CM) NOTE: MAKE SURE CENTRAL TUBE PROTRUDES 0.25-IN. BEYOND YOKE CLAMP KIT PLATE AND SCREWS A Figure 24. Install Clamp Kit 7. Install rubber grommet around central tube, if needed (Figure 25). Note, select thickest rubber grommet that will fit between central tube and yoke. INSTALL RUBBER GROMMET OVER CENTRAL TUBE, IF NEEDED (SELECT THICKEST RUBBER GROMMET THAT WILL FIT) BASE CENTRAL TUBE RUBBER GROMMET INSTALLED A Figure 25. Install Rubber Grommet (If Required) Page , Tyco Electronics Corporation. All Rights Reserved.

25 ADCP Issue 2, May Install clamp kit yoke and top plate and tighten down with hex nuts (2). (Figure 26). HEX NUTS (2) PROVIDED WITH CLAMP KIT TOP PLATE YOKE A Figure 26. Install Clamp Kit Yoke and Top Plate 9. Figure 27 shows the cable clamp kit installed. CABLE CLAMP KIT INSTALLED A Figure 27. Cable Clamp Kit Installed Page Tyco Electronics Corporation. All Rights Reserved.

26 10. Place cover over ribbon fibers making sure ribbon fibers are not twisted or bent (Figure 28). INSTALL COVER A Figure 28. Install Cover 11. Secure cover to base using four screws (provided). (Optional) Carefully fill breakout kit with water blocking gel and re-install hole plug (Figure 29). (Optional) Number tubes with labels (provided). REMOVE HOLE PLUG, FILL CAVITY WITH WATER BLOCKING GEL, AND REPLACE HOLE PLUG FILL WITH WATER BLOCKING GEL SECURE COVER WITH SCREWS (4) A Figure 29. Install Water Blocking Gel into Hole in Cover Page , Tyco Electronics Corporation. All Rights Reserved.

27 ADCP Issue 2, May RIBBON IFC CABLE KIT (BLK-RIFC) Figure 30 shows the catalog scheme for the Ribbon IFC Cable Kit. RIBBON IFC CABLE BREAKOUT KIT BLK-RIFC- RIBBON COUNT A 12-FIBER RIBBON B 24-FIBER RIBBON NUMBER OF PROTECTIVE TUBES CENTRAL TUBE OUTSIDE DIAMETER B C.200"-.325" (5.0mm - 8.2mm).325"-.425" (8.2mm mm) PROTECTIVE TUBING CUTTING TOOL 0=NOT INCLUDED C=INCLUDED B Figure 30. Ribbon IFC Cable Kit Catalog Scheme Page Tyco Electronics Corporation. All Rights Reserved.

28 1. Strip outer cable jacket to expose inner central tube (Figure 31). Clean residue from outside of central tube to prevent slippage when block is attached. 2. Strip central tube back 0.75 to 1.00-inches (min) to expose bare ribbons. (Ribbon fiber length determined by equipment specifications.) Note: A maximum of 5 meters (16.4 feet) of bare fiber can be fed through an oval tube. RIBBON FIBERS CENTRAL TUBE OUTER CABLE JACKET LENGTH DETERMINED BY EQUIPMENT SPECIFICATIONS.75 TO 1.00-IN. (1.9 TO 2.54 CM) OUTER CABLE JACKET STRIP OUTER CABLE JACKET BACK TO EXPOSE CENTRAL TUBE OUTER CABLE JACKET STRIPPED BACK CENTRAL TUBE.75 TO 1.00-IN. (1.91 TO 2.54 CM) STRIP CENTRAL TUBE BACK TO EXPOSE RIBBON FIBERS NOTE: RIBBON FIBER LENGTH DETERMINED BY EQUIPMENT SPECIFICATIONS CLEAN RESIDUE FROM OUTER CENTRAL TUBE A RIBBON FIBERS 12 OR 24 FIBERS Figure 31. Strip Outer Jacket and Subunit Jacket Page , Tyco Electronics Corporation. All Rights Reserved.

29 ADCP Issue 2, May Place black strip tape (provided) around entire end of central tube (Figure 32). Note: Locate tape so cable ties will cover tape surface when attached to the base. PLACE BLACK STRIP TAPE AROUND ENTIRE END OF CENTRAL TUBE A Figure 32. Place Tape on End of Central Tube Page Tyco Electronics Corporation. All Rights Reserved.

30 4. Clean each ribbon fiber according to local practice (Figure 33). Caution: Do not use alcohol packets (provided) for cleaning ribbon fibers, use the alcohol packets to lubricate the ribbon fibers before inserting them into the oval tubes. 5. After cleaning ribbon fibers, use alcohol wipes (one per oval tube) to lubricate the top and bottom of the ribbon fibers before inserting them into oval tube.! CAUTION: DO NOT USE ALCOHOL PACKETS (PROVIDED WITH KIT) FOR CLEANING RIBBON FIBERS. USE ALCOHOL PACKETS (ONE PER OVAL TUBE) TO LUBRICATE THE RIBBON FIBERS BEFORE INSERTING THEM INTO OVAL TUBES. CLEAN EACH RIBBON FIBER ACCORDING TO LOCAL PRACTICE. ONE RIBBON FIBER. REPEAT CLEANING PROCEDURE FOR EACH RIBBON FIBER A Figure 33. Clean and Lubricate Ribbon Fibers Page , Tyco Electronics Corporation. All Rights Reserved.

31 ADCP Issue 2, May Carefully feed ribbon fibers through oval tubes (Figure 34). Note: Feed up to six, 12-fiber ribbons into each tube at the same time. Note: The oval tubes and retainer plate are shipped pre-assembled as shown. NOTE: OVAL TUBES AND RETAINER PLATE ARE SHIPPING PRE-ASSEMBLED RETAINER PLATE OVAL TUBE (4) CAREFULLY, FEED RIBBON FIBERS THROUGH OVAL TUBES (UP TO SIX, 12-FIBER RIBBONS PER TUBE)! WHEN FEEDING RIBBON FIBERS INTO TUBES, FEED UP TO SIX, 12 FIBER RIBBONS INTO THEIR RESPECTIVE TUBE AT THE SAME TIME A Figure 34. Insert Ribbon Fibers into Oval Tubes Page Tyco Electronics Corporation. All Rights Reserved.

32 7. Insert cable ties (2) up through holes in bottom of base (Figure 35). BASE INSERT CABLE TIES UP THROUGH HOLES IN BASE CABLE TIE A Figure 35. Insert Cable Tie into Base Page , Tyco Electronics Corporation. All Rights Reserved.

33 ADCP Issue 2, May Align face plate with face plate pocket in base and place central tube assembly into base (Figure 36). Adjust central tube either forward or backward to the location shown in the lower view. Note: Central tube assembly includes central tube, ribbon fibers, face plate and oval tubes. FACE PLATE ALIGN FACE PLATE WITH FACE PLATE POCKET AND PLACE CENTRAL TUBE ASSEMBLY INTO BASE FACE PLATE POCKET BASE CENTRAL TUBE POSITION BEFORE ADJUSTING FORWARD ADJUST THE LOCATION OF THE CENTRAL TUBE FORWARD (OR BACKWARD) IF NECESSARY CENTRAL TUBE POSITION AFTER ADUSTING FORWARD MAKE SURE CENTRAL TUBE IS POSITIONED IN BASE AS SHOWN. CENTRAL TUBE IN CORRECT POSITION A Figure 36. Place Central Tube Assembly into Fanout Base Page Tyco Electronics Corporation. All Rights Reserved.

34 9. Route the cable tie around the central tube and down through the other side of the base (Figure 8). Cinch the cable tie and cut off excess portion. ROUTE CABLE TIE AROUND CENTRAL TUBE AND DOWN THROUGH OPPOSITE SIDE OF BASE. CINCH CABLE TIES CUT EXCESS CABLE TIE A Figure 8. Install Cable Ties (2) Page , Tyco Electronics Corporation. All Rights Reserved.

35 ADCP Issue 2, May Secure cover onto base using two screws (Figure 9). SECURE COVER WITH SCREWS (2) INSTALL COVER COVER SECURED A Figure 9. Install Top Cover onto Base Page Tyco Electronics Corporation. All Rights Reserved.

36 5 CUSTOMER INFORMATION AND ASSISTANCE PHONE: U.S.A. or CANADA Sales: Extension Technical Assistance: Connectivity Extension: Wireless Extension: EUROPE Sales Administration: Technical Assistance: EUROPEAN TOLL FREE NUMBERS Germany: UK: Spain: France: Italy: ASIA/PACIFIC Sales Administration: Technical Assistance: ELSEWHERE Sales Administration: Technical Assistance: ADC Telecommunications (S PORE) PTE, LTD; 100 Beach Road, #18-01, Shaw Towers. Singapore Tyco Electronics Corporation PO Box 1101, Minneapolis, MN , USA TE European Customer Service, INC Belgicastraat 2, 1930 Zaventem, Belgium PDF copies of manuals are available for downloading at the following link: ADCP Number: Contents herein are current as of the date of publication. TE reserves the right to change the contents without prior notice. In no event shall TE be liable for any damages resulting from loss of data, loss of use, or loss of profits and TE further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. Page Tyco Electronics Corporation. All Rights Reserved.

NG4access ODF Platform Standard Chassis Installation Manual

NG4access ODF Platform Standard Chassis Installation Manual NG4access ODF Platform Standard Chassis Installation Manual TECP-90-703 Issue 1 8/2012 24939-A Content Page INTRODUCTION...1 1 PRODUCT DESCRIPTION...2 2 MAIN COMPONENTS...3 3 GROUNDING AND BONDING THE

More information

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement FIST-EDSA I N S T A L L A T I O N I N S T R U C T I O N FIST-EDSA-D4 Content 1 Introduction 2 Kit content 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop

More information

Seal Kits for BUDI Enclosures

Seal Kits for BUDI Enclosures Description BUDI is a product range of compact, wall mountable fiber enclosures for indoor and outdoor use. They are specifically designed for fast deployment and easy customer connection. The FIST management

More information

DS3/STS-1 Protected Repeater System User Manual

DS3/STS-1 Protected Repeater System User Manual 13959-A ADCP-61-061 Issue 3 August 2000 DS3/STS-1 Protected Repeater System User Manual 8289-A 8288-A 23-Inch, 16-Slot Chassis 19-Inch, 12-Slot Chassis (shown with 23-inch extension brackets) 8287-A Portable

More information

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall FIST-SB2-8 I N S T A L L A T I O N I N S T R U C T I O N Small Box for Cable Termination Contents 1 Introduction 1.1 Product description 2 General 2.1 Tools 2.2 Kit contents 3 Installation and pre-assembling

More information

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box Installation Instructions Description The JBM-100-LBTV2 is a Type 4X-rated connection kit. It is designed

More information

RayClic Connection System

RayClic Connection System RayClic Connection System RayClic-S Splice Kit RayClic-T Tee and End Seal Kit RayClic-X Cross and End Seal Kit Installation Instructions Description These kits are for use with Raychem IceStop, XL-Trace

More information

TE Connectivity's AMP NETCONNECT Cable Management

TE Connectivity's AMP NETCONNECT Cable Management One of the major challenges facing cabling mounting holes installers and maintenance personnel is organizing distribution cables and patch cords in the telecommunications room. TE Connectivity's AMP NETCONNECT

More information

C Electrical Connection Kit

C Electrical Connection Kit 1548-4010C Electrical Connection Kit For Use With Dekoron 2700 and 2300 Family of Heating Cables Installation Instructions Kit Description The Dekoron 1548-4010C electrical connection and end seal kit

More information

ST. KITTS CEILING FAN

ST. KITTS CEILING FAN ITEM #0845047 ST. KITTS CEILING FAN MODEL #40829 Questions, problems or missing parts? Before returning this item to your retailer, call our customer service department at 1-800-643-0067, Monday - Thursday,

More information

FOSC. Fiber Optic System Technology. Fiber Optic Splice Closures (FOSC-400)

FOSC. Fiber Optic System Technology. Fiber Optic Splice Closures (FOSC-400) FOSC Ordering Guide FOSC Fiber Optic System Technology Fiber Optic Splice Closures (FOSC-400) This document provides assistance with the selection of FOSC-400 closures. It includes the following sections:

More information

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30) P. 1 of 12 JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30) Item: Qty: Description: 1 2 1 x 1 x 5/8 Tee Fitting 2 2 Plastic Snap-in Hose Grommet 3 4 1-1/2" Hose Clamps

More information

Room Sensor for BACnet VAV Actuator

Room Sensor for BACnet VAV Actuator BACnet VAV Actuator Room Sensor Installation Manual IM 1038 Group: Controls Part Number: IM 1038 Date: 3/4/2010 Supersedes: New Room Sensor for BACnet VAV Actuator Model(s): 2508031 & 2508032 2010 McQuay

More information

ELSTON 52 CEILING FAN

ELSTON 52 CEILING FAN ELSTON 52 CEILING FAN MODEL #10290 Español p. 21 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883, Monday - Thursday, 8 am -

More information

The FTA-02 Fiber Arranger

The FTA-02 Fiber Arranger The FTA-02 Fiber Arranger Guide To Operation Sumitomo Electric Lightwave Corp. 78 Alexander Drive Research Triangle Park, NC 27709 Telephone: (919) 541-8100 Toll Free: (800) 358-7378 www.sumitomoelectric.com

More information

Model IOR-MA4280/4285 T1 Repeater) Mounting Shelf (4-Inch, 28-Position) User Manual)

Model IOR-MA4280/4285 T1 Repeater) Mounting Shelf (4-Inch, 28-Position) User Manual) Model IO-MA480/485 epeater) Mounting Shelf (4-Inch, 8-Position) User Manual) 4069-A Model IO-MA480/485 Content Page ODUCION... evision History... rademark Information... elated Publications... PODUC DESCIPION...

More information

CUSTOMER SERVICE. Toll-free:

CUSTOMER SERVICE. Toll-free: Rev Aug/1 Rotary Disc Humidifier (All Models) Installation & User Manual IMPORTANT Thank you for selecting the Desert Spring Rotary Disc Humidifier. Carefully read this manual before starting your installation.

More information

Sound Cover [ , , , ]

Sound Cover [ , , , ] Sound Cover [77001603, 77001604, 77001605, 77001606] Intended Use: To provide lower sound (dba) levels for Midmark PowerAir Compressors. Requirements / Restrictions: After cover is mounted to compressor,

More information

Installation and Maintenance Manual IM 1038

Installation and Maintenance Manual IM 1038 Installation and Maintenance Manual IM 1038 BACnet VAV Actuator Room Sensor Group: Controls Part Number: IM 1038 Date: March 2010 Models 2508031 and 2508032 Table of Contents Introduction.... 2 Revision

More information

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here: DISHWASHER Models DW2432 and DW2432SS Installation Manual Write Serial Number (on inner door of unit) here: Felix Storch, Inc. Summit Appliance Division 770 Garrison Avenue Bronx, New York 10474 www.summitappliance.com

More information

Hydraulic Crimping Systems

Hydraulic Crimping Systems ORIGINAL INSTRUCTIONS Hydraulic Crimping Systems Customer Manual 409-35004 04 OCT 17 Rev A SAFETY PRES READ THIS FIRST!... 2 SAFETY PRES AVOID INJURY READ THIS FIRST!... 3 1. INTRODUCTION... 4 2. INSPECTION

More information

SOLARLOK Interconnection System Installation Manual

SOLARLOK Interconnection System Installation Manual SOLARLOK Interconnection System 1. Safety Note! n The SOLARLOK connector is to be used only to interconnect firmly fixed cables. n Do not disconnect under electrical load! n Electrical current path should

More information

C A Heating Cable Gland Kit

C A Heating Cable Gland Kit C75-100-A Heating Cable Gland Kit Installation Instructions Description The C75-100-A is a NEMA 4X rated gland kit used to transition heating cables into a junction box when making connections off of a

More information

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive) 36 & 48 E-Z Cone Fan Installation & Operator s Instruction Manual (Direct Drive) September 1997 MV1433C Chore-Time Warranty Chore-Time Equipment warrants each new product manufactured by it to be free

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC Thermostatic Mixing Valve 605XTMV Certified to comply with ASME A.8.M 005 American Standard M968808 Specifications Installation Adjust Temperature Service Replacement

More information

COOPER POWER SERIES. S.T.A.R. TM Fiber optic cable installation instructions. Fault Indicators MN320004EN. Fiber optic fitting (To led display)

COOPER POWER SERIES. S.T.A.R. TM Fiber optic cable installation instructions. Fault Indicators MN320004EN. Fiber optic fitting (To led display) Fault Indicators MN320004EN Effective March 2017 Supersedes August 2004 (S320-42-2) S.T.A.R. TM Fiber optic cable installation instructions COOPER POWER SERIES Fiber optic fitting (To led display) Mounting

More information

INSTALLATION INSTRUCTIONS TOOLS YOU WILL NEED GETTING STARTED

INSTALLATION INSTRUCTIONS TOOLS YOU WILL NEED GETTING STARTED INSTALLATION INSTRUCTIONS HONEYCOMB SHADES STANDARD RECTANGULAR Thank you for your purchase. This shade has been custom built for you from the highest quality materials. To avoid errors and save valuable

More information

FEB 15 Rev C

FEB 15 Rev C ORIGINAL INSTRUCTIONS Double-Action Hand Tool (DAHT) Lithium-Ion Battery-Powered Crimping Tool Kits 2217483-[ ] Customer Manual 409-32028 13 FEB 15 Rev C SAFETY PRES READ THIS FIRST!... 2 1. INTRODUCTION...

More information

High-Density Industrial

High-Density Industrial Installation Instructions 1 High-Density Industrial Drawers in Shelving BORROUGHS CORPORATION 3002 N. BURDICK STREET * KALAMAZOO, MI 49004-3483 800-748-0227 * FAX: 269-342-4161 Industrial Drawer Installation

More information

JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS JB-RTD-STAND with Raychem heating cable DESCRIPTION The Raychem JB-RTD-STAND is a combination

More information

BUDI-M-SP. Building distributor. Introduction. Seals. Kit content. Accessories. Wrap around cable seals

BUDI-M-SP. Building distributor. Introduction. Seals. Kit content. Accessories. Wrap around cable seals BUDI-M-SP I N S T A L L A T I O N I N S T R U C T I O N Building distributor Introduction Suitable for FTTH applications where easily pre-connectorized splittersmodules can be build in. The box is designed

More information

DS 2001 REVISED Humidifier Assembly and Instruction Manual

DS 2001 REVISED Humidifier Assembly and Instruction Manual DS 2001 REVISED Humidifier Assembly and Instruction Manual Contents Parts list Selecting a location Assembly Hanging the Basin Electrical connections Water connections 2 4 4 Installing the Disk Wheel Installing

More information

GelCap SL. GelCap SL splice cover kits quickly and con-veniently insulate, seal, and protect stub splice connections up to 1000 volts.

GelCap SL. GelCap SL splice cover kits quickly and con-veniently insulate, seal, and protect stub splice connections up to 1000 volts. Cold-Applied Splices GelCap SL Stub splice cover kit with connector for use with street lighting (1000 V) 34 Tyco Electronics GelCap SL splice cover kits provide quick installation, dependable performance,

More information

TECK-40 Series 1000V Class Splice for 4/C Armored Teck Power Cables

TECK-40 Series 1000V Class Splice for 4/C Armored Teck Power Cables Product Installation Instructions TECK-0 Series 000V Class Splice for /C Armored Teck Power Cables Raychem Tyco Electronics - Energy 8000 Purfoy Road Fuquay-Varina, NC 756 PII-598 Rev AC The following

More information

XAGA 550/550-L. Aerial Splice Closure. 1. General Description. 2. Warnings. 3. Cautions

XAGA 550/550-L. Aerial Splice Closure. 1. General Description. 2. Warnings. 3. Cautions XAGA 550/550-L Aerial Splice Closure I N S T A L L A T I O N I N S T R U C T I O N S 1. General Description 1. This practice provides information regarding the description and use of the XAGA 550/550-L

More information

CEILING FAN OWNER S MANUAL

CEILING FAN OWNER S MANUAL Style that revolves around you. CEILING FAN OWNER S MANUAL Total fan weight *53 lbs. WEXFORD 11/05 WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout.

More information

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY PUMPS WITH MOTORS 1. No assembly required. Unpack the pump and motor and examine for any

More information

DPM-G DPM-CR DPM-W DPM-B INDOOR DOME PENDANT MOUNT INSTALLATION MANUAL

DPM-G DPM-CR DPM-W DPM-B INDOOR DOME PENDANT MOUNT INSTALLATION MANUAL DPM-G DPM-CR DPM-W DPM-B INDOOR DOME PENDANT MOUNT INSTALLATION MANUAL MANUAL NUMBERS 517646-1960 517645-1960 517702-1960 517783-1960 Ultrak, Inc. 4465 Coonpath Road NW Carroll, OH 43112 (740) 756-9222

More information

MOUNTING INSTRUCTIONS

MOUNTING INSTRUCTIONS A-12093 JDX 2014 HEATER KIT With Gas Engine Connection Fittings 2014 and Newer ROPS Cabs A-12098 (Kit A-12092, Diesel Engine Connection Fittings are sold separately for diesel models) 12VDC, 2-Speed, 15,000

More information

Technical Publication

Technical Publication Technical Publication Installation Guidelines - HELIAX FiberFeed Solutions for RRH Systems Fiber/Copper Cables: RFF-16SM-812-APE RFF-16SM-810-APE RFF-16SM-808-APE Related Support and Learning Opportunities

More information

HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS

HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS DESCRIPTION The Raychem HWT-P Power Connection and End Seal Kit is for use with HWAT heating cables. Materials for one power connection

More information

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Model Name Type 2A Models Owner s Guide and Installation Manual Model No. Date

More information

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE. Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. ITEM #0331094 0331096 MAYFIELD CEILING FAN MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE Serial Number Purchase

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Siphonic Ultra-High Efficiency Two-Piece Toilets HOptimum Single Flush Models 88AA / 88CA / 88DA HOption Dual Flush Models 886 / 88 / 889 Thank you for selecting American Standard

More information

SUTTON 52 CEILING FAN

SUTTON 52 CEILING FAN SUTTON 52 CEILING FAN MODELS #50188, 50189, 50190 Español p. 19 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883, Monday - Thursday,

More information

Model T B Intraoffice T1 Repeater User Manual

Model T B Intraoffice T1 Repeater User Manual Model 544-01B Intraoffice Repeater User Manual Model 544-01B 15404-A Content Page INTRODUCTION... 1 Revision History... 2 Trademark Information... 2 1 PRODUCT DESCRIPTION... 2 2 SPECIFICATIONS... 5 3 INSTALLATION...

More information

TT3000 and TT5000 Series

TT3000 and TT5000 Series TT3000 and TT5000 Series Bulk Sensing Cable Installation Instructions General Notes Do s and Don ts General Information These instructions detail techniques used to install TT3000 or TT5000 bulk sensing

More information

TOUCHDOWN 48 CEILING FAN

TOUCHDOWN 48 CEILING FAN TOUCHDOWN 48 CEILING FAN MODEL #50205 Español p. 20 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883, Monday - Thursday, 8 am

More information

FEB 16 Rev T

FEB 16 Rev T ORIGINAL INSTRUCTIONS Hand Crimping Tools 46673, 46673-1, and 46988 for STRATO-THERM* Terminals Instruction Sheet 408-1535 12 FEB 16 Rev T PROPER USE GUIDELINES Cumulative Trauma Disorders can result from

More information

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Model Name Type 2A Models Owner s Guide and Installation Manual Model No. Date

More information

Torrena 42 Ceiling Fan

Torrena 42 Ceiling Fan Torrena 42 Ceiling Fan Owner s Manual Part # 269268, 269269 Model # 32096, 32097 Exclusively Distributed by: HD Supply Facilities Maintenance, Ltd. Atlanta, GA 30339 2017 Made in China If you are experiencing

More information

EET V-9 white PVC Labels

EET V-9 white PVC Labels EET V-9 white PVC Labels Technical Datasheet TTDS-207 Revision 1 - September 2017 EET V-9 is a thermal transfer printable white, soft-pvc label with a permanent acrylic adhesive, ideal for rounded, irregular

More information

Data Sheet. Self regulating heating tapes. RS stock numbers

Data Sheet. Self regulating heating tapes. RS stock numbers Data Pack K Issued September 2001 232-3125 Data Sheet Self regulating heating tapes RS stock numbers 379-312 The information contained within this sheet regarding applications and installation of RS WinterGard

More information

BURWELL BIDET TOILET SEAT INSTALLATION

BURWELL BIDET TOILET SEAT INSTALLATION BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing plumbing fixtures. Signature Hardware accepts no liability for any damage to the product, plumbing, toilet,

More information

Camarillo 52 Ceiling Fan

Camarillo 52 Ceiling Fan Owner s Manual Camarillo 52 Ceiling Fan Part # 269263, 269259, 269287 Model # 32091, 32092, 32087 Exclusively Distributed by: HD Supply Facilities Maintenance, Ltd. Atlanta, GA 30339 2017 Made in China

More information

AMP SUPERSEAL 1.5 SERIES Connectors

AMP SUPERSEAL 1.5 SERIES Connectors Introduction Tyco Electronics has developed the MP SUPERSEL 1.5 SERIES Connector family to meet the increasing requirements for reliability and water proofness. MP SUPERSEL 1.5 SERIES Connector exceed

More information

Heat Exchanger Block Replacement Instructions

Heat Exchanger Block Replacement Instructions Series 1-4 Gas-fired water boiler Heat Exchanger Block Replacement Instructions Ultra-80 S1-4 Heat Exchanger Block Replacement Kit, Part No. 383-500-773 Ultra-105 S1-4 Heat Exchanger Block Replacement

More information

Introducing Hermaphroditic Blade and Receptacle Connector

Introducing Hermaphroditic Blade and Receptacle Connector Introducing Hermaphroditic Blade and Receptacle Connector Wire-to-Board, Board-to-Board and Dust Cover Hermaphroditic Blade and Receptacle Connector : Wire-to-Board KEY FEATURES Available in 2, 4, and

More information

INSTRUCTIONS PARTS LIST For President, Monark, Standard, and Fast-Flo Pumps, and Agitator

INSTRUCTIONS PARTS LIST For President, Monark, Standard, and Fast-Flo Pumps, and Agitator INSTRUCTIONS PARTS LIST 308 466 KEEP FOR REFERENCE STAINLESS STEEL, PASSIVATED Drum Covers Part No. 37 306 Drum Cover, Series A For President, Monark, Standard, and Fast-Flo Pumps, and 06 758 Agitator

More information

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,

More information

CBT Bowl & wrap replacement

CBT Bowl & wrap replacement CBT bowl & wrap replacement 2 CBT BOWL & WRAP REPLACEMENT Revision History rev. level 01_03.14.2012 rev. level 02_03.19.2012 rev. level 03_03.23.2012 rev. level 04_05.30.2013 NOTE: due to the fact that

More information

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES INSTALLATION INSTRUCTIONS WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES STANDARD CORDLESS LIFT Thank you for your purchase. This blind has been custom built for you

More information

INSTALLATION INSTRUCTIONS. Vertical Blinds

INSTALLATION INSTRUCTIONS. Vertical Blinds 1 INSTALLATION INSTRUCTIONS Vertical Blinds Vinyl & Fabric Thank you for your purchase. This blind has been custom built for you from the highest quality materials. To avoid errors and save valuable time,

More information

Manual No: Revision: D. Sump Sensor. Installation Guide

Manual No: Revision: D. Sump Sensor. Installation Guide Manual No: 576013-301 Revision: D Sump Sensor Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties

More information

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR ANDROID

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR ANDROID INSTALLATION GUIDE FOR ANDROID This document describes the installation of the Measurement Specialties sensor tag application for Android devices. Contents 1 Installation... 2 1.1 Prerequisite... 22 1.2

More information

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive Installation & Operator s Instruction Manual July 1998 MV1383B Chore-Time TURBO TM Fan Extended Warranty Chore-Time Equipment warrants new TURBO

More information

Instant Hot Water Dispenser Owner s Manual

Instant Hot Water Dispenser Owner s Manual Model Hot1 Instant Hot Water Dispenser Owner s Manual Installation, Care & Use Instalacion, cuidado & uso Installation, soin et utilisation WHAT YOU SHOULD KNOW BEFORE YOU BEGIN For your satisfaction and

More information

OPERATOR S MANUAL. BASIC PROJECT CENTERS Some instructions and drawings may not apply to your specific unit. SAFETY SERVICE PARTS CAPACITIES

OPERATOR S MANUAL. BASIC PROJECT CENTERS Some instructions and drawings may not apply to your specific unit. SAFETY SERVICE PARTS CAPACITIES OPERATOR S MANUAL BASIC PROJECT CENTERS Some instructions and drawings may not apply to your specific unit. SERVICE PARTS LOCATING MODEL # INFORMATION Model number and other information required for service

More information

FLUSH WATER SAVER DUAL FLUSH KIT

FLUSH WATER SAVER DUAL FLUSH KIT FLUSH CH ICE Version 12.26.08 FC002 WATER SAVER DUAL FLUSH KIT Dear Consumer; You have purchased a high quality water saver dual flush toilet valve kit. Every care has been taken during manufacturing to

More information

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS TID-0137_0A TECHNICAL INSTRUCTIONS AM Series Boiler Heat Exchanger Maintenance & Replacement For all models of AM Series Boilers, Including: Boilers: AM 399B AM 500B AM 750B AM 1000B Water Heaters: AM

More information

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. COMPOSITE FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. COMPOSITE FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES INSTALLATION INSTRUCTIONS WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES COMPOSITE FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES POLYMER FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES STANDARD CORDLESS LIFT Thank you for

More information

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION DUVAL 52 CEILING FAN MODELS #50201, 50206 Español p. 19 LISTED FOR DAMP LOCATION Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883,

More information

HVS S Splice Series

HVS S Splice Series HVS-3-2520S Splice Series 25kV lass Splice for 3 Extruded Dielectric (Poly/EPR) Power ables: Metallic Tape, Wire Shield, UniShield, or Lead Sheath ables Suggested Installation Equipment (not supplied with

More information

Installation/Operation Instructions COMP-COOL50/COMP-COOL50P 50 CFM COMPONENT COOLERS

Installation/Operation Instructions COMP-COOL50/COMP-COOL50P 50 CFM COMPONENT COOLERS Installation/Operation Instructions COMP-COOL50/COMP-COOL50P 50 CFM COMPONENT COOLERS (I)COMP-COOL50 (I)COMP-COOL50P Thank you for purchasing the (I)COMP-COOL50/(I)COMP-COOL50P Component Coolers. Please

More information

TSL-Aerofoil. wall mounted basin. installation + maintenance

TSL-Aerofoil. wall mounted basin. installation + maintenance TSL-Aerofoil wall mounted basin installation + maintenance contents 3 Contents 4 Technical Data 5 Before You Install 8 Assembly 11 How to Install 14 Maintenance 15 Cleaning 17 Warranty 18 Contact Details

More information

THE VALOR CEILING FAN INSTALLATION INSTRUCTIONS

THE VALOR CEILING FAN INSTALLATION INSTRUCTIONS THE VALOR CEILING FAN INSTALLATION INSTRUCTIONS Please read and save these instructions These instructions are to be used in the installation of the following QUORUM INTERNATIONAL fans... The Valor 2011

More information

UV-SCE. Ultra-Violet light, Resistant TECHNICAL DATASHEET. Heat Shrink Identification Marker Sleeves

UV-SCE. Ultra-Violet light, Resistant TECHNICAL DATASHEET. Heat Shrink Identification Marker Sleeves UV-SCE Ultra-Violet light, Resistant Heat Shrink Identification Marker Sleeves TECHNICAL DATASHEET Revision 4, March 2015 UV-SCE Ultra-Violet Light Resistant, Heat Shrink Identification Marker Sleeves

More information

HVS S 15kV Class

HVS S 15kV Class Product Installation Instructions HVS-3-1520S 15kV lass Splice for 3/ Extruded Dielectric (Poly/EPR) Power able: Metallic Tape, WireShield, or UniShield able * UniShield is a registered trademark of I

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC Hard-Wired AC Powered ICU Lavatory Proximity Faucet PRODUCT NUMBER 0. Certified to comply with ASME A..M 0 American Standard M 0. ICU Faucet shown Installed on American

More information

Gardian W51. Approvals

Gardian W51. Approvals Gardian W51 120 V pre-assembled electric heating cables for pipe freeze protection and roof & gutter de-icing Installation Instructions Description Gardian W51 120 V pre-assembled self-regulating heating

More information

AVANI Grinding Booth

AVANI Grinding Booth AVANI Grinding Booth GB-6066-DD Customer: Kelly Walsh Customer PO#: 11305 AVANI SO#: Serial #: 153920-153921 Ship Date / Install Date: Tested By: Please read and save these instructions. Read carefully

More information

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT) TE Connectivity's (TE) FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, TE s FTTX solutions

More information

Quick Reference Guide Barrier Strips

Quick Reference Guide Barrier Strips Quick Reference Guide Barrier Strips Barrier strip style terminal blocks from Tyco Electronics are available in 3 main categories: dual-barrier, tri-barrier, and double row. Each category of barrier strip

More information

ASG EZ-9000GR Tape Dispenser User Manual ASG #66136

ASG EZ-9000GR Tape Dispenser User Manual ASG #66136 ASG EZ-9000GR Tape Dispenser ASG #66136 Revision Date: 03/27/18 1 Read Before Use Warnings and Cautions The safety guidelines in this instruction manual must be observed in order to prevent injury to the

More information

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions Installation, Operating and Servicing Instructions Wall Mounted Water Boiler WMB3F/B,WMB3F/W Please make a note of your product details for future use: Date Purchased: Model Number: Serial Number: Dealer:

More information

PIPE DREAMS 96. Aeroponic Garden IMPORTANT:

PIPE DREAMS 96. Aeroponic Garden IMPORTANT: 1 WARNING: BEFORE PUTTING WATER PUMP INTO OPERATION FILL UP NUTRIENT TANK TO TOP OF PUMP. THE PUMP MUST NEVER RUN DRY OTHERWISE, WARRANTY WILL BE DECLINED. READ FILLING INSTRUCTIONS BEFORE USE. Welcome

More information

FAUX WOOD BLINDS 2 & 2-1/2 SLAT SIZES

FAUX WOOD BLINDS 2 & 2-1/2 SLAT SIZES INSTALLATION INSTRUCTIONS FAUX WOOD BLINDS 2 & 2-1/2 SLAT SIZES STANDARD RECTANGULAR Thank you for your purchase. This blind has been custom built for you from the highest quality materials. To avoid errors

More information

THE ALUMINA CEILING FAN INSTALLATION INSTRUCTIONS

THE ALUMINA CEILING FAN INSTALLATION INSTRUCTIONS THE ALUMINA CEILING FAN INSTALLATION INSTRUCTIONS Please read and save these instructions These instructions are to be used in the installation of the following QUORUM INTERNATIONAL fans... The Alumina

More information

Cable Drum Machine. Operation Manual 40 SERIES. Cleans 2" to 4" lines up to 75' N O T F O R R O O T S

Cable Drum Machine. Operation Manual 40 SERIES. Cleans 2 to 4 lines up to 75' N O T F O R R O O T S Cable Drum Machine Operation Manual 40 SERIES Cleans 2" to 4" lines up to 75' Used For: Sinks, Showers & Floor Drains N O T F O R R O O T S WARNING - Read All Instructions, When Using Electric Tools, Basic

More information

Installation Instructions

Installation Instructions Installation Instructions For Fully Integrated NoFrost Combined Refrigerator-Freezers HC 2062 HCB 2062 HC/HCB 20 7082 373-00 Important PLEASE READ AND FOLLOW THESE INSTRUCTIONS These instructions contain

More information

Side Entry Bushing (SEB) High Temperature Cable Clamp Bushing Installation Instructions

Side Entry Bushing (SEB) High Temperature Cable Clamp Bushing Installation Instructions Page: 1 of 6 High Temperature Cable Clamp Bushing is a strain relief, and stress protection product that can be placed around a wire bundle and under a saddle clamp backshell adapter after the contacts

More information

Troubleshooting the MPH 24FP Series Pedestal Hydrant

Troubleshooting the MPH 24FP Series Pedestal Hydrant MAPA Products P.O. Box 129 Naples, Texas 75568 Toll Free: 877 897 2371 How the Hydrant Works: Troubleshooting the MPH 24FP Series Pedestal Hydrant The design of the hydrant assembly is based on a venturi

More information

Installation Instructions. Remanufactured Veeder-Root Sump Sensor. PMP # 62208, Replaces Veeder-Root # , -209

Installation Instructions. Remanufactured Veeder-Root Sump Sensor. PMP # 62208, Replaces Veeder-Root # , -209 Manual Number: 01-60-291 Revision : 5.6 Date: 12/11/15 Installation Instructions Remanufactured Veeder-Root Sump Sensor PMP # 62208, 62209 Replaces Veeder-Root #794380-208, -209 Contents Disclaimer...

More information

Forteza Series Granite Kitchen Sink

Forteza Series Granite Kitchen Sink INSTALLATION MANUAL Forteza Series Granite Kitchen Sink KGD-50 / KGD-52 / KGD-54 / KGU-55 www.kraususa.com I Toll Free: 1.800.775.0703 I 2017 Kraus USA Inc. I REV. November 2, 2017 Thank you for your purchase

More information

THE ELICA CEILING FAN INSTALLATION INSTRUCTIONS

THE ELICA CEILING FAN INSTALLATION INSTRUCTIONS THE ELICA CEILING FAN INSTALLATION INSTRUCTIONS Please read and save these instructions These instructions are to be used in the installation of the following QUORUM INTERNATIONAL fans... The Elica 2007

More information

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above Installation and Operation Manual CLEARVIEW DAY COVER To view a video scan the QR code above CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

More information

Introducing SlimSeal SSL Connector

Introducing SlimSeal SSL Connector Introducing SlimSeal SSL Connector The SlimSeal SSL connectors are low profile, single row connectors developed for indoor and outdoor LED lighting applications. These connectors provide low power, sealed

More information

BlueHeat AirTop 2000 Heater

BlueHeat AirTop 2000 Heater BlueHeat AirTop 000 Heater Air Heater Installation Manual Ford E-Series 6.0L Diesel Beginning Model Year: 006 Special instructions for these models Part locations may differ slightly dependent on the vehicle

More information

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment This manual is Copyright 2019 Duke Manufacturing Co.

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information