Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight
|
|
- Cuthbert Bishop
- 5 years ago
- Views:
Transcription
1 Directional Luminaire Test Report For ELEC-TECH INTERNATIONAL CO LTD No. 1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R.China LED Downlight Model name(s): ## Representative (Tested) Model: Model Difference: ##=00-10 intends CCT is 2700K, ##=41-50 intends CCT is 4000K Prepare By: Review By: Engineer: Technical Lead: Date: Date: Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Laboratory: Dongguan New Testing Centre Co., Ltd Page 1 / 26
2 Photo of Sample Laboratory: Dongguan New Testing Centre Co., Ltd Page 2 / 26
3 Annex Regulatory Body Test Method Regulation or Program Tests to Test Limit Per Regulation Measured or Evaluated to Determine or Program Requirement Efficiency or Fail Compliance Limit Level 9. PHOTOMETRIC PERFORMANCE REQUIREMENTS Luminaire Efficacy 60 lm/w lm/w (initial) Luminaire Minimum 575 lm lm Light Output (initial) Section 9.2 Luminaire Zonal % Lumen Density One of the following nominal correlated color temperatures Rated Correlated Color Temperature (CCT) (CCTs): 2700 Kelvin 3000 Kelvin 3500 Kelvin 2700 K 4000 K Section Kelvin 5000 Kelvin One of the following target correlated color temperatures Measured Correlated Color Temperature (CCT) (CCTs): 2725 ± 145 K 3045 ± 175 K 3465 ± 245 K 2670 K 3834 K (@ 120Vac) 3985 ± 275 K 5028 ± 283 K Section 9.4 Color Rendering Index (CRI) Ra 80 & R9 > 0 Ra= 82.8 R9= 12 (@ 120Vac) The variation of chromaticity shall be within a total linear Color Angular distance of from the Uniformity weighted average point on the CIE 1976 (u,v ) diagram. Section 9.5 Laboratory: Dongguan New Testing Centre Co., Ltd Page 3 / 26
4 10. LUMEN MAINTENANCE AND RATED LIFE REQUIREMENTS Shall meet the following L70 rated lumen maintenance life Lumen Maintenance values, in situ: indoor >54000 hours Section 10.1 outdoor inseparable luminaires 1. In the sample luminaire, the in situ TMPLED temperature is less than or equal to the temperature specified in the LM-80 test report Maximum In-Situ for the corresponding or higher 99.1 C 105 C Source Temperature drive current. 92 ma 150 ma 2. The drive current measured in (@ 120Vac) Section 10.1 the luminaire is less than or equal to the drive current specified in the LM-80 test report at the corresponding temperature or higher. Shall meet the following L70 lumen maintenance life vales: 25,000 hours for indoor Section 10.2 Light Source Life 35,000 hours for outdoor luminaires 50,000 hours for inseparable luminaires For all LM-80 samples, at any measurement point, the distance of the chromaticity coordinates Section 10.3 Color Maintenance from the initial (zero-hour) chromaticity coordinates shall not exceed at the temperature(s) adjacent to the measured in situ TMPLED LM-80 report has been verified and the chromaticity shift (Δu v ) is temperature, and at the corresponding drive current. Laboratory: Dongguan New Testing Centre Co., Ltd Page 4 / 26
5 11. ELECTRICAL PERFORMANCE REQUIREMENTS Light source shall remain Source Start Time continuously illuminated within 750 milliseconds of application 310 ms 120Vac) Section 11.1 of electrical power. Total luminaire input power 5 watts: Power Factor PF 0.5 Total luminaire input power > (@ 120Vac) Section 11.3 watts: PF 0.7 Section 11.4 Transient Protection The line transient shall consist of seven strikes of a 100 khz ring wave, 2.5 kv level, for both common mode and differential mode. During and after test, the product operated normally Standby Power Luminaires shall not draw power 0 W Consumption in the off state. (@ 120Vac) Section 11.5 Operating Frequency 120 Hz Hz (@ 120Vac) Section LUMINAIRE SERVICEABILITY REQUIREMENTS LED light engines or retrofit kits shall make use of electrical interconnects that allow for Light Source consumer replacement of the Validated Replaceability engine or kit without the cutting Section 12.1 of wires or the use of solder. Wire nuts and other reusable connectors are allowed. Ballast/Driver shall make use of Section 12.2 Ballast/Driver Replaceability electrical interconnects that allow for consumer replacement of the ballast/driver without the cutting of wires or the use of solder. Wire nuts and other reusable Validated connectors are allowed. Laboratory: Dongguan New Testing Centre Co., Ltd Page 5 / 26
6 13. THERMAL PERFORMANCE REQUIREMENTS At the temperature measurement point for the hottest location on the driver case (TMPC as detailed by the driver manufacturer), the Maximum Measured measured driver case temperature 90.1 C<95 C Ballast or Driver at thermal equilibrium shall not (@ 120Vac) Case Temperature exceed the driver manufacturer s Section 13.1 maximum recommended temperature during in situ (installed in the luminaire) operation. Insulation contact (Type IC): Recessed Downlight Recessed downlights marketed as Thermal Type IC shall be approved for Performance zero clearance insulation cover Section 13.2 by an OSHA NRTL laboratory. 14. SAFETY REQUIREMENTS Demonstrate compliance with ANSI/UL , ANSI/UL Fixtures) Indoor Luminaire , ANSI/UL 1598C- Validated Validated Eligibility Criteria Safety 2014, ANSI/UL , Version 2.0 ANSI/UL , as Section 14.1 applicable. Demonstrate compliance with Fixtures) Electronic Ballast or ANSI/UL , ANSI/UL Validated Validated Eligibility Criteria Driver Safety , ANSI/UL , Version 2.0 as applicable. Section 14.2 Laboratory: Dongguan New Testing Centre Co., Ltd Page 6 / 26
7 15. CONTROL REQUIREMENTS Fixtures) Eligibility Criteria Version 2.0 Section 15.1 Dimming The luminaire and its components shall provide continuous dimming from 100% to 20% of light output. Luminaire shall not emit noise above 24dBA at 1 meter or less at the minimum output dba Product must continue to comply with the applicable product safety Products with standards the addition of the Fixtures) Connected functionality shall not override Eligibility Criteria Functionality existing safety protections and Version 2.0 (Optional) functions. Section 15.2 Must comply with section 11.5 Standby Power. Laboratory: Dongguan New Testing Centre Co., Ltd Page 7 / 26
8 16. PRODUCT LABELING & PACKAGING REQUIREMENTS Labeling & Packaging Packaging and marketing claims shall represent the product consistent with its certification. Validated Packaging shall clearly describe the nominal color designation of the lamp in units of Kelvin (e.g. 2700K, 3000K) and may display recommended corresponding nomenclature as outlined below. Validated Labeling & This can also be met through use Packaging of a Lighting Facts label (as applicable) Soft White Section Warm White 3500 Neutral White 4000/4100K Cool White 5000K Daylight For luminaires shipped with lamps containing mercury: Both the lamp and the luminaire Labeling & packaging shall have a label Packaging indicating mercury content which must be managed and disposed of properly, and shall reference: For outdoor luminaires: Labeling & Packaging Packaging shall indicate the minimum (lowest) starting temperature for the lamp and ballast platform of the luminaire. Laboratory: Dongguan New Testing Centre Co., Ltd Page 8 / 26
9 For luminaires marketed as dimmable: Luminaire packaging shall indicate dimming range (as applicable), a list or web site address with compatible dimmers or other controls, and known Labeling & Packaging incompatibilities with dimmers, occupancy or vacancy sensors, timing devices or other external Validate lighting controls, or a message noting limitations and web site address to find out more specific information. Step dimming capability, if employed, shall be clearly indicated. For recessed downlight luminaires that are insulation- Labeling & Packaging contact (Type IC) rated: Packaging shall clearly state this rating. Sample language: IC- rated for direct contact with insulation. For recessed downlight luminaires that are airtight (AT) certified: Packaging shall indicate that the Labeling & luminaire permits air leakage less Packaging than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E Sample language: Certified airtight per ASTM E Section 16.2 Light Source Shipment Complete light source components shall be provided with the luminaire or retrofit kit. Validated Laboratory: Dongguan New Testing Centre Co., Ltd Page 9 / 26
10 17. WARRANTY REQUIREMENTS Integrated LED lamps shipped with the luminaire shall carry a minimum 3 year warranty. Section 17 Warranty For luminaires incorporating nonreplaceable drivers, the above warranty requirement is extended to 5 years. Warranty language shall place no 5 years limitations on coverage based on duration of luminaire operation (e.g. hours per day). Laboratory: Dongguan New Testing Centre Co., Ltd Page 10 / 26
11 Product Information: Client Name: ELEC-TECH INTERNATIONAL CO LTD Brand Name: ETI Model Number: ##(##=00-10 or ##=41=50) Product type: LED Down Light Rating Input: AC120V, 60Hz, 10.5W Declared CCT: 2700K, 4000K Declared Light output: 670lm Declared Lifetime: 50000h LED Manufacturer: Samsung LED Model: SPMWH1221 LED Quantity: 24 pcs Forward current of LED Chip: 150 ma Date of Receipt Samples: ; Quantity of Receipt Samples: 3,1 Sample Number: S1~S3 for ##(##=01-10) S1 for ##(##=41-50) Dimming type: Continuous Dimming Test Dimmer Manufacture: LUTRON Test Dimmer Model: DV-603P Laboratory Information: Test Laboratory: Dongguan New Testing Centre Co., Ltd Laboratory Address: 3F, No. 1 the 1 st North Industry Road, Songshan Lake Science & Laboratory Contact Name: Neil Zhong Laboratory Contact Neil_ntc@163.com Report Information Issued Date of Test Report: Revised Date of Test Report: Test Report No.: NTCR Remark (If applicable) Technology Park, Dongguan, Laboratory: Dongguan New Testing Centre Co., Ltd Page 11 / 26
12 Test Specifications: Date of Test to Test item 1. Total Luminous Flux Reference Standard 2. Luminous Distribution Intensity 3. Luminous Efficacy 4. Correlated Color Temperature 5. Color Rendering Index 6. Chromaticity Coordinate 7. Color Angular Uniform 8. Transient Protection 9. Operation Frequency 10. Source Start Time 11. In-Situ Temperature Measured Test (ISTMT) 12. Maximum Measured Ballast Driver Case Temperature IES LM Electrical and Photometric Measurements of Solid-State Lighting Products ANSI C Specifications for the Chromaticity of Solid State Lighting Products CIE Method of Measuring and Specifying Colour Rendering Properties of Light Sources CIE Technical Report Colorimetry ANSI/IEEE C62.41 (Category A) Recommended Practice on Surge Voltages in Low Voltage AC Circuits ANSI/UL Luminaire Test Methods 1. Photometric and Electrical measurements Light Distribution Method: Photometric parameters were measured using the goniophotometer and software. The ambient temperature shall be maintained at 25 C ± 1 C, measured at a point not more than 1 m from the sample and at the same height as the sample. The sample was operated at 120 Volts AC, 60Hz. It was stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were calculated from the software taken at 1 vertical intervals and 22.5 Vertical intervals. 2. Photometric and Electrical Measurements Integrating Sphere Method: Photometric parameters were measured using an integrating sphere, a spectroradiometer and software. The ambient temperature condition inside the sphere was maintained at 25ºC ± 1ºC. The sample measurements were made using a spectroradiometer connected by a fiber optic cable and detector through the detector port of the integrating sphere. The sample was operated at 120 Volts AC, 60Hz. It was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature and color rendering index were calculated from the spectral radiant flux measurements taken at least 5 nm intervals over the range of 380 to 780 nm. Laboratory: Dongguan New Testing Centre Co., Ltd Page 12 / 26
13 3. Color Angular Uniform The sample was tested according to the IES LM Photometric parameters were measured using type C goniophotometer and software. The ambient temperature shall be maintained at 25±1 C, measured at a point not more than 1 m from the sample and at the same height as the sample. The sample was operated at 120 Volts Ac, 60Hz. It was stabilized before measurement was made. Color spatial uniformity was calculated from the software taken at 1 vertical intervals and 90 horizontal intervals. Transient Protection Test The transient protection tests at ambient temperature were performed on one sample. The sample was operated at rated input voltage in the base - up orientation during the tests. Test system with an 100kHz Ring Wave Module and a Coupler/Decoupler Module was used to generate the 2500 volt ring wave transient strike across the lamp base contacts. Each wave consisted of a 0.5 microsecond rise time. Seven strikes were performed on each lamp sample in accordance with ANSI/IEEE C62.41 (Category A): Recommended Practice on Surge Voltages in Low Voltage AC Circuits. Operation Frequency Each test sample was operated at rated input voltage. The sample was operated at 120 Volts AC, 60Hz.Light output waveform shall be measured by a Flicker Photometer. Source Start Time & Run-Up Time Each test sample was operated in its designated orientation at rated input voltage in a 25±5 C ambient. The sample was operated at 120 Volts AC, 60Hz.A photodetector is used to monitor the luminaire light output. Time shall be measured by a Flicker Photometer. In-Situ Temperature Measurement Test (ISTMT) Maximum led source operating temperature measurements were taken on one test sample per model with a thermocouple and temperature meter. The SSL sample was allowed to reach thermal equilibrium for at least 3 hours before measurements were taken. Led source temperature was measured at the point as indicated by the included diagram in accordance with manufacturers declared hot spot location. The maximum temperature was recorded for the sample. A simulated ceiling or other enclosure may be used in accordance to UL 1598 as applicable. Maximum Measured Ballasted or Driver Case Temperature Maximum driver case temperature measurement was taken on one test sample per model with a thermocouple and temperature meter. The SSL sample was allowed to reach thermal equilibrium for at least 3 hours before measurements were taken. Driver case temperature was measured at the point as indicated by the included diagram in accordance with manufacturers declared hot spot location. The maximum temperature was recorded for the sample. A simulated ceiling or other enclosure may be used in accordance to UL 1598 as applicable. Laboratory: Dongguan New Testing Centre Co., Ltd Page 13 / 26
14 Integrating Sphere Test Results for Test Condition: Test Ambient Test Humidity Orientation Stabilization Time Test Time 25.5 C 40 % Face Down 90 min 25 min Electrical Data: Voltage (Vac) Frequency (Hz) Current (A) Power (W) Power Factor Color Data: Parameter Result Special Color Rendering CCT (K) 2670 R1 82 R9 12 Color Rendering Index (CRI) 82.8 R2 93 R10 85 R9 12 R3 94 R11 79 Chromaticity, x R4 80 R12 78 Chromaticity, y R5 82 R13 85 Chromaticity u R6 93 R14 97 Chromaticity v R7 81 R15 74 Duv R Spectrum Diagram: Laboratory: Dongguan New Testing Centre Co., Ltd Page 14 / 26
15 Integrating Sphere Test Results for Test Condition: Test Ambient Test Humidity Orientation Stabilization Time Test Time 25.2 C 44 % Face Down 90 min 25 min Electrical Data: Voltage (Vac) Frequency (Hz) Current (A) Power (W) Power Factor Color Data: Parameter Result Special Color Rendering CCT (K) 3834 R1 82 R9 13 Color Rendering Index (CRI) 83.9 R2 90 R10 76 R9 13 R3 96 R11 82 Chromaticity, x R4 83 R12 67 Chromaticity, y R5 82 R13 84 Chromaticity u R6 86 R14 98 Chromaticity v R7 87 R15 76 Duv R Spectrum Diagram: Color Angular Uniformity for Test Result Maximum u'v' Laboratory: Dongguan New Testing Centre Co., Ltd Page 15 / 26
16 Goniophotemeter Test Results for : Test Condition: Test Ambient Test Humidity Orientation Stabilization Time Test Time 25.1 C 37 % Face Down 90 min 25 min Electrical Data: Voltage (Vac) Frequency (Hz) Current (A) Power (W) Power Factor Goniophotometer Data: Parameter Result Total Luminous (lm) Total Luminous per foot (lm/ft) Luminous Efficacy (lm/w) Zonal Lumens Distribution (0-60 ) 84.5% Beam Angle ( ) Center Beam Candle Power (cd) Luminous Intensity Distribution Diagram: Laboratory: Dongguan New Testing Centre Co., Ltd Page 16 / 26
17 Isocandela Diagram: Laboratory: Dongguan New Testing Centre Co., Ltd Page 17 / 26
18 Zonal Flux Diagram: Laboratory: Dongguan New Testing Centre Co., Ltd Page 18 / 26
19 Luminous Distribution Intensity Data: Laboratory: Dongguan New Testing Centre Co., Ltd Page 19 / 26
20 Source Start Time for : Test Result Start Time (ms) 310 Operating Frequency Test for : Test Result Operating Frequency (Hz) Laboratory: Dongguan New Testing Centre Co., Ltd Page 20 / 26
21 Power Factor Test for : Test Result Power Factor Standby Power Consumption for : Test Result Power Consumption (W) 0 Transient Protection Test for : Dimming Test for : Test Result After Test Work Normal Test Result 100% Light Output (lm) Min. Light Output (lm) Dimming Level % Laboratory: Dongguan New Testing Centre Co., Ltd Page 21 / 26
22 In-Situ Temperature Measurement Test (ISTMT) for Electrical Data: Voltage (Vac) Frequency (Hz) Current (A) Power (W) Power Factor Orientation Stabilization Time Test Time (hours) Face Down 7.5 Test Result Thermocouple Location Measured LED Drive Current (ma) Temperature ( C) Ambient Test Result Corrected to 25 C Limits ( C) TMP LED Test Result from TM-21 LM-80 Test Inputs Description of LED Light Source Tested Test Data for 55⁰C Case Test Data for 85⁰C Case Test Data for 105⁰C Case (manufacturer, model, catalog number) Temperature Temperature Temperature Samsung Electronics Co., LTD. SPMWH1221 Time Time Lumen Maintenance Time Lumen Maintenance (%) Lumen Maintenance (%) (hours) (hours) (%) (hours) % % % % % % % % % % % % % % % LM-80 Testing Details % % % Total number of units tested per case temperature: % % % Number of failures: % % % Number of units measured: % % % Test duration (hours): % % % Tested drive current (ma): Tested case temperature 1 (Tc, ⁰C): Tested case temperature 2 (Tc, ⁰C): Tested case temperature 3 (Tc, ⁰C): In-Situ Inputs Drive current for each LED package/array/module (ma): In-situ case temperature (Tc, ⁰C): Percentage of initial lumens to project to (e.g. for L70, enter 70): Results Time (t) at which to estimate lumen maintenance 50, (hours): Lumen maintenance at time (t) (%): 87.43% Reported L70 (hours): > Laboratory: Dongguan New Testing Centre Co., Ltd Page 22 / 26
23 Thermocouple Position on TMP Laboratory: Dongguan New Testing Centre Co., Ltd Page 23 / 26
24 Maximum Measured Driver Case Temperature for Electrical Data: Voltage (Vac) Frequency (Hz) Current (A) Power (W) Power Factor Orientation Stabilization Time Test Time (hours) Face Down 7.5 Test Result Thermocouple Location Temperature ( C) Limits ( C) Ambient Test Result Corrected to 25 C TMP Driver Thermocouple position on TMP Laboratory: Dongguan New Testing Centre Co., Ltd Page 24 / 26
25 Equipment List: Equipment ID Equipment Name Last Cal. Due Cal. NTC-F Goniophotometer System NTC-F meter Integrating Sphere NTC-F Standard Lamp NTCD-S001 Temperature Data Logger NTCD-S049 Digital Phosphor Oscilloscope NTC-F Digital Power Meter NTC-F Surge Generator NTC-F Temperature & Humidity Meter Laboratory: Dongguan New Testing Centre Co., Ltd Page 25 / 26
26 *****END OF DATASHEET***** Laboratory: Dongguan New Testing Centre Co., Ltd Page 26 / 26
NVLAP LAB CODE ISTMT Test Report. For IROCO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD
ISTMT Test Report For IROCO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD Aotom LED Industrial Park, Qingzhuanzhu Road 268, Huanggang, Hubei, China LED Panel Light Model name(s): 22AP3235A (CLC/WLC FPL22-835-32W-130LW-UNV-DIM1-WH)
More informationREPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045
REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE 100402-0. Project No. G101030158 Date: February 26, 2013 REPORT NO. 101030158CRT-001 TEST OF ONE LED
More informationREPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045
REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 100402-0.. Project No. G101537614 Date: April 8, 2014 REPORT NO. G101537614CRT-005 TEST OF ONE LED
More informationREPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727
REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727 Project No. G101464624CRT-001 Date: January 17, 2104 INTERTEK REPORT NO. G101464624CRT-001 DIALIGHT REPORT NO. L13029 TEST OF ONE LSA ATEX ZONE
More informationREPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630
FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 17025:2005. REPORT 25800 COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 Project No. G101786356 Date: August 19, 2014 REPORT NO. 101786356LAX-001 TEST OF
More informationREPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005
. REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102671575 Date: July 27, 2016 REPORT NO. 102671575CHI-002 TEST OF ONE ROADWAY/AREA LUMINAIRE MODEL NO. APL-NW200 LED MODEL NO. SAMSUNG
More informationEnergy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015
Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015 Version 2.0 January, 2015 Prepared for Pacific Gas and Electric Company San Francisco, California Prepared by Energy Solutions
More informationNVLAP LAB CODE In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: AOK)
In Situ Temperature Measurement Test Report For AOK LED Light Company Limited (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province,
More informationLED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright
T8 PBT8-DL5004EFX-U AC 100V-277V Day Light 5000K Pure Bright LED retrofits! Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! With the highest safety rating available, UL Listed,
More informationREPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005
. REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102748333 Date: December 20, 2016 REPORT NO. 102748333CHI-015 TEST OF ONE T8 LED TUBE MODEL NO. T8-NW18F LED MODEL NO. HONGLI OPTO-ELECTRONIC
More informationREPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005
. REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102748333 Date: January 24, 2017 REPORT NO. 102748333CHI-018 TEST OF ONE LED EPLOSION PROOF LIGHT MODEL NO. EPL-NW200 LED MODEL NO.
More informationIn Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: ) Outdoor Pole/Arm-Mounted Area and Roadway Luminaires
In Situ Temperature Measurement Test Report For AOK LED Light Company Limited (Brand Name: ) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province,
More informationREPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005
. REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102748333 Date: February 21, 2017 REPORT NO. 102748333CHI-024 TEST OF ONE LED WALL PACK MODEL NO. WPFC-CW70 LED MODEL NO. PHILIPS
More informationProject: Comments: Prepared By: Control. Code Fixture & Trim D3 Wall Wash, Round. Platform & Control Wide Gamut, Tunable
Project: Comments: Prepared By: Tunable, fixture produces a wide range of 90+ CRI/R9 whites from 1400K-10,000K, as well as pastels and saturated colors Closed-loop color point maintenance to
More informationENERGY STAR Program Requirements
Report No.: LCZP17050329 Version: 1.0 Date Of Issue: Jun. 17, 2017 Total Pages: 17 Test Report of ENERGY STAR Program Requirements for Luminaires V2.0- Inseparable SSL Luminaires Applicant: ELEC-TECH INTERNATIONAL
More informationT8 Self Ballasted UL & CSA LED TUBE RETROFITS
T8 Self Ballasted UL & CSA LED TUBE RETROFITS Sept. 2011 Part Numbers T8 LED TUBE TECHNICAL SPECIFICATIONS Part Numbers LR-T8-17W-3.2-1200 LR-T8-17W-4.5-1200 LR-T8-17W-6.5-1200 LRT8-23WW-FS2 LRT8-23CW-FS2
More informationNVLAP LAB CODE For. Shen Zhen Green Works Lighting Co., Ltd. Floor 4, Bldg. A, No. 36-8, Yingtai Road,Dalang, Longhua, SHENZHEN,China.
In Situ Temperature Measurement Test Report For Shen Zhen Green Works Lighting Co., Ltd (Brand Name: Green Works Lighting) Floor 4, Bldg. A, No. 36-8, Yingtai Road,Dalang, Longhua, SHENZHEN,China. High-bay
More informationProject: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable
S3 Tunable Lamp Fully tunable spectrum single point source produces wide range of 9+ CRI white, pastels and saturated colors Closed-loop color point maintenance to
More informationLED Reliability and Current Standards for Measurement
LED Reliability and Current Standards for Measurement DOE SSL Workshop July, 2010 Eric Richman Pacific Northwest National Laboratories Program Name or Ancillary Text eere.energy.gov Life and Reliability
More informationProject: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable
S38 Tunable Lamp Fully tunable spectrum single point source produces wide range of 9+ CRI white, pastels and saturated colors Closed-loop color point maintenance to
More informationSECTION INTERIOR LIGHTING
SECTION 26 51 00 INTERIOR LIGHTING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationFast. Precise. Versatile. UL Lighting Sciences
Fast. Precise. Versatile. UL Lighting Sciences As the world turns to LED and SSL technology as a primary source of electric light, UL Lighting Sciences continues to build upon our industry-leading technical
More informationLED Panel Light E830J
LED Panel Light E830J Light Emission Technology www.lightemissiontech.com High energy efficiency 20W LED panel light Luminous update 1700Lm High power factor Over temperature protection High uniformity
More informationENERGY STAR Program Requirements for Residential Light Fixtures. Eligibility Criteria Version 4.2. Table of Contents
ENERGY STAR Program Requirements for Residential Light Fixtures Eligibility Criteria Version 4.2 Table of Contents Section 1: Definitions II Section 2: Qualifying Products V Section 3: Energy Efficiency
More informationOUTPUT RANGE: VIVID SERIES
POINT SOURCE OPTICS Exceptional beam control enables unique 1 narrow spot and smooth uniform beams Single light source, single crisp shadow VP 3 COLOR & VP 3 NATURAL WHITE series provides accurate color
More informationDOME SERIES. Data will be subject to change without notice. COMMERCIAL 1
DOME SERIES Fully integrated downlight luminaires for easy deployment and installation, perfect for commercial and/or residential applications alike whereby a classic downlight is required with minimal
More informationNVLAP LAB CODE In Situ Temperature Measurement Test Report. For SHENZHEN SUNPER OPTO CO.,LTD. (Brand Name: SUNPER)
In Situ Temperature Measurement Test Report For SHENZHEN SUNPER OPTO CO.,LTD (Brand Name: SUNPER) 5/F,BLOK C,SANMIN INDUSTRIAL PARK,SHIYAN STREET, BAO AN DISTRICT,SHENZHEN 518108,GUANGDONG,CHINA High-Bay
More informationTable of Contents. Product Description. Features. CLM-DS08 Rev 9A. Product family data sheet. Source with. Characteristics - WhiteLight Dimming...
Cree LMH2 LED Modules Product family data sheet CLM-DS8 Rev 9A LMH2 Light Source with LMH2 Light Source with Product Description Features Table of Contents www.cree.com/modules Cree LED modules provide
More informationFortimo LED Line High Flux Module
Fortimo LED Line High Flux Module Fortimo LED line 2ft 4000lm 1R LV1 The Fortimo LED Line high flux systems consist of linear white light LED modules with high flux, high energy efficiency, and high quality
More informationProduct Description. Features. Table of Contents. CLM-DS08 Rev 11. Product family data sheet. Source with
Cree LMH2 LED Modules Family Product family data sheet CLM-DS8 Rev 11 LMH2 Light Source with LMH2 Light Source with Product Description Features Table of Contents www.cree.com/modules Cree LED modules
More informationChallenges in SSL Design and Photometric testing Gautam Brahmbhatt, Head Technical (Verification Service)
Challenges in SSL Design and Photometric testing Gautam Brahmbhatt, Head Technical (Verification Service) 2011 Underwriters Laboratories Inc. Date: Jan 6, 2012 Agenda Introduction Challenges in SSL design
More informationELLA ID. High CRI, High lm/w OptoDrive LED-module
ELLA ID ELLA ID High CRI, High lm/w OptoDrive LED-module Page 2 of 24 Pages for reference: Pages for reference:... 2 Introduction... 3 Short form Characteristics... 4 Wiring diagram:... 6 Accessories to
More informationDimmable LED Retrofit Kit
ASD LED Recessed Retrofit Kit was designed as an energy-efficient lighting solution for remodeling or new construction projects. It is an ideal replacement for an incandescent lamp in the industry s most
More informationTHE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination
THE HIGH PERFORMANCE LED Fixture Series for General, Direct and Indirect Illumination KEY FEATURES INCLUDE: Advanced Thermal Management Industry Leading Deep Fin Heat Sinks with Aircraft Grade Aluminum
More informationLED Fire Rated Downlight
LED Fire Rated Downlight 7.5W Dimmable/Non-Dimmable Fire Rated Downlights with Emergency Option. Product Overview The Kosnic LED Fire Rated Downlight with integrated LED light engine achieves high lumen
More informationRecessed and surface mounted LED downlight family
Recessed and surface mounted LED downlight family The SylFlat LED family provides the perfect integrated LED solution for the replacement of traditional CFL downlights. The range is offered in 3 different
More informationCLM 422 Series LED Ceiling Luminaire Module - 45Watt
Product Information The CLM422 LED Ceiling Luminaire Module is the first truly engineered commercial grade (2'x 2') LED office light designed to replace fluorescent fixtures of much higher wattage classes.
More informationAnnexure-I. 1. Goniophotometer and Goniospectroradiometric measurement System
Technical specifications of C-type Goniophotometer System with mirror arrangement for measurements of Photometric and Colorimetric parameters of Lamps, Luminaires and SSL Lighting Devices 1. Goniophotometer
More informationPhilips MASTER LEDbulb 7-40 W and W E27/B K 230 V
MASTER LEDbulb Technical Application Guide Philips MASTER LEDbulb 7-40 W and 10-60 W E27/B22 2700 K 230 V The first dimmable LED replacement for a 40 W and 60 W GLS bulb with warm white light all around.
More informationLED Linear Design Highlights
LED Linear Design Highlights Advanced Thermal Management Industry Leading Deep Fin Heat Sinks with Aircraft Grade Aluminum and 9 (23cm) [min] of perimeter conductive surface. Multiple Color Options Three
More informationOverview of International Lighting Standards Steve Coyne Director, Light Naturally UNEP Consultant
Overview of International Lighting Standards Steve Coyne Director, Light Naturally UNEP Consultant International Standards Bodies: Relevant to Lighting International Organisations International Organisation
More informationCLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights.
CLARA AC CLARA AC Crystal CLARA AC 50 LED-modules for downlight A qualified solution to replace and exceed Halogen solutions in Downlights. No Driver is required! Page 2 of 24 Designed for downlight and
More informationCree XLamp MT-G MR16 Reference Design
Cree XLamp MT-G MR16 Reference Design APPLICATION NOTE CLD-AP62 REV 0 Figure 1: MR16 assembly (left: Carclo TIR optic, right: Ledil reflector optic) TABLE OF CONTENTS INTRODUCTION WWW. CREE.COM/XLAMP Introduction...
More informationSafety Certification of Solid-State Lighting Products. September 23, 2009 Todd Straka Director - Lighting Services
Safety Certification of Solid-State Lighting Products September 23, 2009 Todd Straka Director - Lighting Services Discussion Points for Today s Webinar Product Safety Certification Process Overview Key
More informationTechnical Application Guide for PHILIPS LED Lamps
Technical Application Guide for PHILIPS LED Lamps 12V PHILIPS EnduraLED 1W MR16 Dimmable Introduction PHILIPS dimmable integrates a leading high power LED light source and a compact high efficiency driver
More informationCONTENTS. Draft Minimum Energy Performance Standards for LED Lighting V6 14 November
CONTENTS SCOPE... 2 All Lamp Categories... 3 Non-directional LED lamps (table 1)... 3 Directional LED lamps (table 1)... 3 Linear LED lamps (table 1)... 3 Planar Luminaires, integrated battens & Troffers
More informationPhilips MASTER LEDbulb DIM W & W E27/B K 230 V
MASTER LEDbulb Technical Application Guide Philips MASTER LEDbulb DIM 13-75 W & 18-100 W E27/B22 2700 K 230 V Dimmable LED replacement for a 75 W/100 W GLS bulb with warm white light all around. Philips
More informationP5500 LED Architectural Downlighting
P5500 LED Architectural Downlighting HIGH TECH ENERGY EFFICIENT DESIGN COMMERCIAL & RESIDENTIAL INDOOR LIGHTING ADVANCED INTEGRATED THERMAL TECHNOLOGY Product Information P5500 is a high output PAR 38
More informationFortimo LED Line Gen2 Module
Fortimo LED Line Gen2 Module Fortimo LED Line 1ft 650lm 3R LV2 Fortimo LED Line systems are designed to replace fluorescent lighting in new luminaires. Fortimo LED Line Gen 2 systems are designed to replace
More informationSolid State Lighting
Solid State Lighting LED Lighting Panel Discussion Department of Environmental Quality 2 Panelists: The Panel Dr. Lynn Davis, Fellow, RTI International Robert Talley, PE, NC Dept. of Administration, State
More informationHigh Lux Performance White LED MR16 Lamp
High Lux Performance White LED MR16 Lamp LuxDot -- delivering the performance of a conventional halogen light source with the benefits of solid state lighting to maximize Lux on Target. LuxDot MR16 replacements
More informationTechnical Application Guide for UP-SHINE LED Track Light
Technical Application Guide for UP-SHINE LED Track Light UP-TL25-25W Introduction LED Track light adopts CREE LEDs with excellent color rendering index to increase the color fidelity of the target illuminated
More informationBasics Series Surface Mount LED Fixtures. Affordable and easy-to-install, 4" and 6" fixtures. It s a. Snap
Basics Series Surface Mount LED Fixtures Affordable and easy-to-install, 4" and 6" fixtures It s a Snap Easiest to install LED fixture ever... and so affordable! There s never been an easier to install
More informationULTRA RT6 and RT6 Gimbal LED Recessed Downlight Kit
www.sylvania.com/rt6 ULTRA RT6 and RT6 Gimbal LED Recessed Downlight Kit Key Features & Benefits Lumen package: 625 lumens @ 11 watts 700 lumens @ 11 watts 900 lumens @ 14 watts Replacement for up to 100W
More informationTRMUNV220ACXXXA UNIVERSAL VOLTAGE HIGHBAY RETROFIT KIT
UNIVERSAL VOLTAGE HIGHBAY RETROFIT KIT Retrofit Kit Suitable for Acrylic Highbays and Lowbays Suitable replacement for applications using 400W HID Instant ON/Off, no cool down time needed 120277V Application
More informationLED Product Catalogue
LED Product Catalogue Valid from 01 March 2014 LED = innovative light 1 Contents LED = innovative light...page 3 Save energy and costs with LED...Page 4 A new light will go off in your head... Page 5 LED
More informationCPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS
ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS PROJECT TYPE YEAR WARRANT Y Prodigy's canopy lights offer a unique combination of energy efficiency, reliability
More informationNon-Cutoff and Semi-Cutoff Wall Pack Primary Use and Edits to Outdoor Wall-Mounted Luminaire Primary Use
Non-Cutoff and Semi-Cutoff Wall Pack Primary Use and Edits to Outdoor Wall-Mounted Luminaire Primary Use DLC proposes to include non-cutoff and semi-cutoff (or "open face") wall packs in the Technical
More informationFahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture
PRODUCT SPECIFICATIONS Frame-in Kit HOUSING: Fire and sound-rated housing. Up to 20 minute fire rated L500 (floor-ceiling) & P500 (roof-ceiling) design. Die formed #24 gauge galvanized steel construction.
More information4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications
4 LED Recessed Adjustable Energy efficient, stylish downlighting for residential and commercial applications The most efficient, stylish, high-performance downlight is now adjustable Juno Generation 4
More informationTechnical Application Guide for UP-SHINE LED Panel Light
Technical Application Guide for UP-SHINE LED Panel Light UP-PL2X4-5W UP-PL2X4-5WD Introduction Up-shine LED troffer adopts LM-8 SMD led chip, with UL&cUL, DLC approved for North America market. 1X4, 2X2,
More informationRecessed LED Wall/Slot SAE 202
5/8" 5 7/16" 6 1/2" 2 5/8" 5/8" 6" 5 7/16" 1 11/16" Fixture Type: Project Name: Ordering Guide Feature Code Options Description Program SAE SAE Program Series Recessed Linear Wall/Slot Ceiling Type DW
More informationE10 & L9 Low Wattage Light Cone Data
E10 & L9 Low Light Cone Data 2W-A-SP 2W-A-NFL 2W-A-FL 3W-SP 3W-NFL 3W-FL 4W-SP 4W-NFL 4W-FL SERIES Toshiba LED Lighting gives you nothing but pure light. At Toshiba, we re illuminating the world by introducing
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 INTERTEK TESTING SERVICES NA, INC. 5 25800 Commercentre Dr. Lake Forest, CA 92630 Mr. Jay Kogoma Phone: 949-448-4100 ELECTRICAL Valid to: December 31, 2017
More informationNEW ENHANCED CAPITAL ALLOWANCE EXPLAINED NEW ECA EXPLAINED HELEN LOOMES 2013/2014 SLL MASTERCLASS
NEW ENHANCED CAPITAL ALLOWANCE EXPLAINED NEW ENHANCED CAPITAL ALLOWANCE EXPLAINED The benefits and new requirements of the scheme The additional benefits of using energy efficient schemes. How to overcome
More informationFPLHB - Fidelux Premier Linear Highbay
FPLHB - Fidelux Premier Linear Highbay Product Description Fidelux LED Linear High Bays meet the challenging maintenance, safety, and performance requirements of industrial environments through an unbeatable
More information2018 Instant Lighting Rebates Product Catalog
MIDSTREAM LIGHTING PRODUCTS Product Code 463993 Interior 4 LED T8 Lamp Product Description Rebate/Unit Page # $5.00/Lamp 8 464791 Commercial LED Candelabra: 1 to
More informationClearAccent - Affordable recessed LED spot
Lighting ClearAccent - Affordable recessed LED spot ClearAccent ClearAccent is an entry-level recessed spot range designed to replace halogen-based luminaires. Its attractive price and high lumen per watt
More informationTubeLine LED unit Optimised comfort with a linear LED solution
Lighting LED unit Optimised comfort with a linear LED solution Fluorescent linear lighting has traditionally been the preferred choice for customers demanding a high level of visual comfort. With excellent
More informationTHE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:
THE HIGH PERFORMANCE LED Luminaire Series for Stairwells, Bathrooms, Passageways, and General Illumination KEY FEATURES INCLUDE: Multiple Color Options Three color options ensure that the new lighting
More informationTechnical Application Guide for UP-SHINE LED Panel Light UP-PL W-E
Technical Application Guide for UP-SHINE LED Panel Light UP-PL66-27W-E Introduction Edge Lit LED Panel luminare combines high reflection material with unique curved design to achieve unparalleled Optical
More informationTechnical Application Guide for UP-SHINE LED Frameless Panel Light
Technical Application Guide for UP-SHINE LED Frameless Panel Light UP-PL66-45W-P Introduction Frameless panel is an improved version compared to regular panels.they are of high lumen output, high CRI>8,
More informationMedical LED. Superbly balanced and colour corrected LED-modules for medical use.
Medical LED Superbly balanced and colour corrected LED-modules for medical use. OptoDrive - complete LED modules for medical luminaires With light fittings used for minor surgery, examination and other
More informationCoreLine Batten the clear choice for LED
Lighting CoreLine Batten the clear choice for LED CoreLine Batten Whether for a new building or renovation of an existing space, customers want lighting solutions that provide quality of light and substantial
More informationOLUX LED Flood Light OSRAM. Datasheet APPLICATIONS.
OLUX LED Flood Light Datasheet OLUX LED FLOOD is a cost-effective, durable and environmentally-preferable LED flood light series. The IP66 outdoor rated OLUX LED FLOOD S, M and L are designed to replace
More information2200TD-3000TD Dim to Warm* 2700T-6500T Tunable White* *Must be ordered with D05 or DS5 Driver options; excludes 2' and 3' lengths
Fixture Type: Project Name: Ordering Guide Feature Code Options Description Program SAE SAE Program Series Mounting CC Concealed Cove Fixture Distribution AI Asymmetric Indirect Row Length (in feet) '
More informationperformance PowerBalance, surface mounted Benefits Features Application Specifications
Lighting PowerBalance surfacemounted sustainable performance PowerBalance, surface mounted When it comes to lighting an office space with LED luminaires, people are usually willing to invest in sustainability
More informationDRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight
DRD5S & SurfaceFrame Alt/EM Project: Product Code: Type: Date: Spec Sheet V- 11.15.18 Maintains all the standard SurfaceFrame ratings Offers enhanced dimming protocol compatibility including Lutron Hi-Lume
More informationDRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light
DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light Project: Product Code: Type: Date: Spec Sheet V- 04.15.19 Maintains all the standard SurfaceFrame ratings Offers enhanced dimming protocol
More informationTechnical Application Guide for UP-SHINE LED Panel Light
Technical Application Guide for UP-SHINE LED Panel Light UP-PL66-36W-S3 Introduction Up-shine led panel adopts high lumen SMD LED with CRI >8. Top branded driver comes with triac dim, -1V dim and DALI
More informationLUXCOMFO TM LED Flood Light Datasheet
Datasheet LUXCOMFO TM LED Flood Light is a very cost-effective LED flood light series. The IP65 outdoor rated flood lights are designed to replace traditional halogen lamps with excellent energy and cost
More informationSuite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass. Finish: Diameter: " Height: 4" Lamp: x
Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass Finish: Diameter: " Height: 4" Lamp: x 352-(&7 =,** &21'26 7
More informationTechnical Application Guide for UP-SHINE LED Panel Light
Technical Application Guide for UP-SHINE LED Panel Light UP-PL33-18W Introduction Up-shine led panel adopts high lumen SMD LED with CRI >8.The ultra slim profile fits seamlessly into any work place. It
More informationLM Series LED Architectural Downlighting HIGH LUMEN OUTPUT RECESS / SURFACE MOUNT GREEN ENERGY EFFICIENT LIGHTING
HIGH LUMEN OUTPUT RECESS / SURFACE MOUNT GREEN ENERGY EFFICIENT LIGHTING Product Information Light Emitting Designs introduces the ultimate in architectural lighting with the latest generation of LED technology
More informationREPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630
REPORT 58 COMMERCENTRE DRIVE, LAKE FOREST, CA 963 Project No. G119188 Date: March 13, REPORT NO. 119188LAX-4 TEST OF ONE LED WASH MODEL NO. COLOUR CHORUS 4 RENDERED TO ELATION PROFESSIONAL 61 S. EASTERN
More informationReflector T2 and GU10 6,000 hours
Reflector T2 and GU1 6, hours 11watt SES E14 Small Screw Cap Equivalent to 6watt R63 information CFL Reflector and GU1 6, hours lamps offer traditional incandescent and halogen shapes and sizes, long life
More informationRA406930NFLWH 4" Led Adj Gimbal 30K 120V Narrow FLD
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 RA406930NFH 4" ed Adj Gimbal 30K 120V Narrow FD Eaton ighting Catalog Number Manufacturer Description eight per unit Product
More informationLHBXD LED Linear High Bay
Catalog # : Project : Prepared By : Date : LHBXD The LHBXD is the perfect solution for a wide variety of applications and mounting heights. It s competitive pricing, multiple lumen packages, and high ambient
More informationCoreLine Recessed Spot the clear choice for LED
Lighting CoreLine Recessed Spot the clear choice for LED CoreLine Recessed Spot CoreLine Recessed Spot is a recessed spot range designed to replace halogen-based luminaires. Its halogen-like look and attractive
More information2016 Title 24, Part 6 Reference Joint Appendices JA8 & JA10 Residential Lighting Test, Certify, & Comply
2016 Title 24, Part 6 Reference Joint Appendices JA8 & JA10 Residential Lighting Test, Certify, & Comply California s High Efficacy Lighting Requirements for Residential Applications Kelly Cunningham Pacific
More informationHALO. 2700K nominal. 3000K nominal. RA4 LED Very Wide Flood (VWFL)
DESCRIPTION The Halo RA4 ED Adjustable Gimbal series are retrofit ED Modules for 4 aperture recessed downlights. The RA4 gimbals feature adjustment of 35-degree tilt and up to 360-degree rotation. In addition
More informationQualified Product Information Form for Residential Ceiling Fans
Qualified Product Information Form for Residential Ceiling Fans ENERGY STAR Product Information Form for Use by ENERGY STAR Residential Ceiling Fan Partners (Companies who have joined ENERGY STAR by signing
More informationSolid State Lighting Sub-Assembly Interfaces for Luminaires. Andrew D. Jackson Philips Lighting Corporate Regulatory and Certification Laboratory
NEMA White Paper - Recommendations for Solid State Lighting Sub-Assembly Interfaces for Luminaires i Andrew D. Jackson Philips Lighting Corporate Regulatory and Certification Laboratory CORM May 8, 2009
More informationTechnical Application Guide for UP-SHINE LED Panel Light
Technical Application Guide for UP-SHINE LED Panel Light UP-PL-45W-S Introduction Up-shine led panel adopts high lumen SMD LED with CRI >8. Top branded driver comes with triac dim, -1V dim and DALI dim,
More informationAOD LED Panel Light AL-PL
The design criteria of the AOD panel light was focused on the essential basic requirements of modern lighting, visibility and eye comfort.with the elimination of the normal mains frequency flicker and
More informationTechnical Application Guide for UP-SHINE LED Panel Light UP-PL W-L
Technical Application Guide for UP-SHINE LED Panel Light UP-PL612-72W-L Introduction Double-sided panel light is designed for special use with decorative effect. 7% light downward and % light upward, it
More informationTechnical-Report for SL Lamp 5 W
Technical-Report for SL Lamp 5 W Technical Report No. 68.184.17.478.01 Dated 2017-06-27 Client: Manufacturing place: Name: PHOCOS China Ltd. Address: 3F 1st Bldg. 4A Chang Yi Road, 266021, Qingdao, PEOPLE'S
More informationCoreLine Recessed Spot the clear choice for LED
Lighting CoreLine Recessed Spot the clear choice for LED CoreLine Recessed Spot CoreLine Recessed Spot is a recessed spot range designed to replace halogenbased luminaires. Its halogenlike look and attractive
More informationCDL8 LED Architectural
Project: Type: Model# CDL8 LED Architectural PRODUCT DESCRIPTION Retrofit Down lights The Luminoso 8 inch Commercial LED Downlight is damp rated, and suitable for 1-277V Input equipped with fire-rated
More informationCove Light AC Dim. Electrical Protection Class II, cetlus. Compatible with and controlled by leading/trailing edge phase-cut dimmers
Date: Quantity: Company: Project: The offers a range of cold, neutral, or warm white with a 135x135 degree wide beam angle for general lighting, wall washing, and alcove illumination. Controlled by leading/trailing
More information