1 and Controller User manual Version 1.0

2 Summary 1 Safety instructions General instructions Intended Usage Qualified personnel Remaining hazards CE Conformity Model Identification Technical Data General Features Hardware Features Software Features Dimensions and Installation Change of setpoint value Table of Anomaly Signals Dimensions and Installation Electrical wirings Wiring diagram Modify configuration s Configuration s Tuning Manual start of tuning LATCH ON Function Neutral zone Function Programming module (optional) Programming module with battery (optional) Loading default value Alarm Intervention Modes Summary of Configuration s...36 UR3274S - User manual 3

3 Introduction Dear valued Customer! Thank you for purchasing and using a product from our company. Various models with 3-4 digits display make the controller suitable for a wide range of applications with temperature, humidity, pressure sensors and linear potentiometers. Output options include two relays and SSR, but the unit is configurable also as visualizer/ indicator for applications not requiring control or alarm outputs. PID control with Autotuning function enables to adapt control algorithm to the plant. For applications with linear potentiometers the function LATCH ON allows a quick calibration. A programming module is available to copy configuration s and to keep record of them. For getting the highest effort out of this unit, we kindly ask you to follow the below mentioned instructions: Every person who is involved with the installation or usage of this unit, must read carefully and understand the installation manual and safety instructions! 1 Safety instructions 1.1 General instructions To ensure the safe operation of this unit the instructions that appear in this manual must be strictly observed. In addition, when used all applicable legal and safety regulations for the respective application must be observed. The same applies correspondingly to the use of accessories. 1.2 Intended Usage Units from the controller series UR3274S are used for displaying and monitoring of process values. Any other use is regarded not in accordance with the intended usage. Units from the controller series UR3274S are not meant to be used as sole safety means to prevent dangerous situations on machinery and installations. Machinery and intallations must be so designed that fault conditions can not lead to harmful situations to operating personnel (e.g. by independent limit value switches, mechanical locking etc.). 1.3 Qualified personnel Units from the controller series UR3274S must only be operated in accordance with the technical specifications by qualified personnel. Personnel regarded qualified is familiar with the installation, assembly, putting into operation and operation of the units and possesses adequate professional qualification for the task. 1.4 Remaining hazards Units from the controller series UR3274S are state of the art and safe to operate. A risk of danger can occur when deployed and operated improperly by untrained personnel. In this manual remaining hazards are marked by the following warning symbol: This symbol indicates that non-observance of the safety guidelines may cause hazards to persons even serious injury or death and/or the possibility of property damage. 4 UR3274S - User manual UR3274S - User manual 5

4 1.5 CE Conformity The CE certificate is available at our company. We are pleased to send you a copy of it. Please feel free and contact us to get a copy. 2 Model Identification Refer to the table below to easily select preferred model. All versions available with power Vac/Vdc +/-15% 50/60Hz 4,6VA UR3274S1 UR3274S3 UR3274A1 UR3274A3 3 Technical Data 3.1 General Features Display Operating temperature Sealing Material Weight VAC +/-10 % 50/60 Hz 12 bis 35 VDC 230 VAC +/-10 % 50/60 Hz VAC +/-10 % 50/60 Hz, 12 bis 35 VDC 230 VAC +/-10 % 50/60 Hz UR3274S1/S3: 3 digits (0,56 inches) UR3274A1/A3: 4 digits (0,40 inches) + 3 Leds (Out1, Out2, L1) 1 relays 8A + 1 Ssr + RS485 IP65 front panel (with gasket) IP30 box, IP20 terminals Polycarbonate UL94V2 self-extinguishing 100 g 3.2 Hardware Features Analogue input Relay output SSR output AN1. Configurable via software. Thermocouple type: K, S, R, J. Automatic compensation of cold junction from 0 C to 50 C. Thermoresistance: PT100, PT500, PT1000, Ni100, PTC1K, NTC10K (β 3435K). Linear: 0-10V, 0-20 or 4-20mA, 0-40mV Potentiometers: 6KΩ, 150KΩ, 2 Relais OUT1 : 10A resistive on UR3274S1 and UR3274A1 8A resistive with internal transformer UR3274S3/ UR3274A3 Tolerance (25 C) +/-0.2 % ± 1 digit for thermocouple input, thermo- resistance and V/mA. Cold junction accuracy 0.1 C/ C Impedance: 0-10V: Ri>110KΩ 0-20mA: Ri<5Ω 4-20mA: Ri<5Ω 0-40mV: Ri>1MΩ Contacts capacity UR3274S1 And UR3274A1: Q1. 10A-250Vac resistive Q2: 5A -250Vac resistive OUT2 : 5A resistive 1 SSR on UR3274S1 and UR3274A1 12Volt-30mA if supplied 12Vdc 35Volt-30mA if supplied 35Vdc UR3274S3 and UR3274A3: Ground / The negative 8Volt-20mA Output is switched 3.3 Software Features Regulation ON-OFF with hysteresis. algorithms P, PI, PID, PD with proportional time Manual or automatic Tuning, configurable alarms, protection of command and alarm Controller functions setpoints, activation of functions via digital input, preset cycle with Start/Stop. 6 UR3274S - User manual UR3274S - User manual 7

5 4 Dimensions and Installation Display normally shows process value (ex. measured temperature), but can also visualize setpoints or value of entering data. Visualize set, increase set or scroll s (whith fast advancement) Visualize set, increase set or scroll s (whith fast advancement) Visualize setpoints (ex. programmed temperature): press once for SET1 (Led Out1 flashes), press twice for SET2 (Led Out2 flashes). In configuration mode press with arrow keys to modify value of visualized. Flashing when setpoint is vvisualized on display and can be modified. ON when output is active. ON when controller responds to a Master request over serial line RS485. Enter configuration of s (by password). Activate special functions. 5 Change of setpoint value SET key or one of the arrow- To modify the setpoint value, press keys: led OUT1 flashes and it is now possible to enter/modify setpoint value by pressing the arrow-keys. 1 2 Press Display Do Press or or or SET SET Display shows control setpoint; Led OUT1 flashes. Display shows alarm setpoint and led OUT2 flashes. 6 Table of Anomaly Signals to modify setpoint (fast advancement available). Approx. 4 seconds after last modify, display shows again process value (value read by sensor input). Press or to increase or decrease setpoint value. When the keys are released, the new value is automatically stored and in a few seconds display shows again process value. Cause What to do Error in E²PROM cell E-01 programming Call Assistance E-02 Cold junction sensor fault or room temperature Call Assistance outside of allowed limits. E-04 Incorrect configuration data. Possible lost of calibration values. Thermocouple open or E-05 temperature outside of limits. E-08 Missing calibration data Call Assistance Check if the configuration s are correct. Check the connection with the sensors and their integrity. 8 UR3274S - User manual UR3274S - User manual 9

6 7 Dimensions and Installation 8.1 Wiring diagram 2 wire 4/20mA Supply 10A 230V Cosf 1 3A 230V Cosf 0.8 Q1 5A 230V Cosf 1 1A 230V Cosf 0.8 Q2 Power V/I PT/NI100/1K +VDC PTC/NTC SSR Tc 1 Programming module Power Supply VAC/ VDC model: UR3274S1; UR3274A V... 12/24V~ VAC ± 10 % 50/60 Hz VDC Power Supply 230 VAC model: UR3274S3; UR3274A3 8 Electrical wirings Although this controller was designed to resist electromagnetic interferences in industrial environments, pease observe following safety guidelines: Separate the feeder line from the power lines. Avoid placing near units with remote control switches, electromagnetic contactors, high powered motors and in all instances use specific filters. Avoid placing near power units, particularly if phase controlled V... 12/24V~ 230 VAC ± 10 % 50/60 Hz 10 UR3274S - User manual UR3274S - User manual 11

7 - AN1 Analogue Input For thermocouples K, S, R, J. Comply with polarity For possible extensions, use compensated cable and terminals suitable for the Shield thermocouples used(compensated) When shielded cable is used, it should be grounded at one side only A B C Tc Shield Shield Shield +VDC V/I + PT/NI100 PTC/NTC ly for UR3274S1 and UR3274A1. To assure optimal operation of the device, use ground-isolated sensors. Otherwise use single isolated transformers for each controller. For thermoresistances PT100, NI100 For the three-wire connection use wires with the same section For the two-wire connection shortcircuit terminals 10 and 12 When shielded cable is used, it should be grounded at one side only RED 12 WHITE 11 RED 10 For thermoresistances NTC, PTC, PT500, PT1000 e potentiometers When shielded cable is used, it should be grounded at one side only to avoid ground loop currents For linear signals V/mA Comply with polarity When shielded cable is used, it should be grounded at one side only Examples of Connection for linear input V PRESSURE TRANSMITTER C 0/4...20mA B EXTERNAL SUPPLY PRESSURE TRANSMITTER /4...20mA B PRESSURE TRANSMITTER C C mA A A For signals 0.10V Comply with polarity Ri>=110KΩ For signals 0/4.20mA with three-wire sensor Comply with polarity C = Sensor output B = Sensor ground A = Sensor power Check power supply requirements on technical data sheet of sensor! Capacity 12 V...35 V/30 ma for UR3274S1/A1 Capacity 8V / 20mA for UR3274S3/A3 For signals 0/4..20mA with external power of sensor Comply with polarity C = Sensor output B = Sensor ground For signals 0/4...20mA with two-wire sensor Comply with polarity C = Sensor output A = Sensor power supply Check power supply requirements on technical data sheet of sensor! Capacity 12 24V / 30mA for UR3274S1/A1 Capacity 8V / 20mA for models UR3274S3/A3 12 UR3274S - User manual UR3274S - User manual 13

8 3 Relay Q1 Output Q2 Q1 SSR output SSR Q1 capacity 8A/250V~ (UR3274S3/ A3) resistive (manoeuvre 2x105min - 8A/250V~) Q1 capacity 10A/250V~ (UR3274S1/A1) resistive (manoeuvre 2x105min -10A /250V~) Q2 capacity 5A/250V~ resistive (manoeuvre 2x105min a 3A /250V~) Capacity 12 35V/30mA on UR3274S1/A1 Capacity 8V/20mA on models A-B-C Command output if configured as SSR 9 Modify configuration s The configuration menu of the unit is password protected to prevent unauthorised access to the instrument set-up. Password cannot be modified. Press Effect Do After 5 seconds display 1 shows 000, first digit Increase or decrease on the left is flashing. main setpoint 0000 on UR3274A1/A FNC SET or Increase first digit to 1. Display shows first configuration c.ou for UR3274S1/S3 c.out for UR3274A1/A3 The arrow-keys allow the movement through the configuration table in both forward and backward directions. Press following digit and enter configuration password 123 for UR3274S1/A1 or 1234 for UR3274S3/A3 SET to reach Select to modify, press visualize it and use arrow keys to modify value. SET to 14 UR3274S - User manual UR3274S - User manual 15

9 10 Configuration s Auswahl Anzeige Beschreibung Beschreibung Control Q1 o1.2 o1.o2 Alarm Q2 (default) Control Q1 o1.s o1.ss Alarm SSR Select type c.ou 1 of control Control SSR ssr ssr output Alarm Q1 c.out Control Q2 o2.1 o2.o1. Alarm Q1 Open Q1 ser seru. Close Q2 TC type K tc.k tc. k Select type (default) of connected tc.s tc. s TC type S sensor. tc.r tc. r TC Type R( C) tc.j tc. J TC Type J( C) ly for pt pt Pt100 ( C) UR3274S1/A1: To assure p t1 p t1 Pt100 ( C) optimal ni ni Ni100 ( C) working of ntc nkc Ntc 10 KΩ( C) 2 SEN. the unit, use ptc pkc Ptc 1 KΩ( C) pts pts Pt500 ( C) p1k p k1k Pt1000 ( C) groundisolated sensors. Otherwise use single isolated transformers for each controller bis 10 V bis 20 ma bis 20 ma po1 po t1 Potentiometer 6 KΩ po2 pot2 Potentiometer 150 KΩ Auswahl Anzeige Beschreibung Beschreibung no decimal point Select 0 (default) position 3 d.p decimal point decimal point decimal points 4 Lo. s. 5 H.i. S. 6 Lo. n. Lower limit selectable for setpoint value Upper limit selectable for setpoint value Lower limit signals V/mA Example: for input 4 20mA, enter on this the value corresponding to 4mA digit digit digit decimal points Degrees for temperature sensors Digits for linear signals digit and potentiometers (default 0) Degrees for temperature sensor Digits for linear signals and potentiometers digit (default: 999 for and 1750 for ) (default 0) digit 16 UR3274S - User manual UR3274S - User manual 17

10 Auswahl Anzeige Beschreibung Beschreibung Upper limit signals V/mA Example: for input mA, (default 999) enter on this digit digit the value corresponding to 20mA 7 Hi. n. 8 9 LAT Latc ca.o cal.o. Function Latch (Automatic setting of limits for potentiometers and linear signals) set calibration. This value is added to the process value visualized on display (usually correcting the ambient temperature) units off std u.0m u.0s units Disabled (default) Standard virtual zero stored virtual zero at start (see par. 23) Tenths of degree for temperature. Digits for linear signals and potentiometers (default 0.0) Auswahl Anzeige Beschreibung Beschreibung Gain calibration of sensor input (The visualized ca.g 10 number is cal.g. 11 reg. 12 s.c.c. multiplied for this % value to calibrate process value) Type of control Type of contact for control output in case of error -19.9% % -99.9%... (default 0.0) +99.9% Hea Heat Heating (N.O.) (default) coo cool Cooling (N.C.) Absolute alarm with m.r. m.r. manual reset of contact Absolute alarm with manual reset; status of m.r.m. m.r.m. relay stored in case of switch-off Heating mode with PID H.o.o. H.o.o. set to 0 if process value is above setpoint value Open contact safety c.o. (default) c.c. Closed contact safety * Parameters 33,34,35,36 are considered only if double action Heating/ Cooling (al. selected as coo) and value of p.b. other than UR3274S - User manual UR3274S - User manual 19

11 Auswahl Anzeige Beschreibung Beschreibung State of c.o. with open contact led OUT1 Ld 1 13 according with closed contact to relevant c.c. (default) Led1 contact ON/OFF HY.c hysteresis or 14 dead band for HYS.c P.I.D. control Proportional band Width of the 15 p.b. process expressed as units ( C if temperature) Integral time. Inertia of 16 t.i. the process expressed as seconds digits digits Tenth of degree for temperature sensor. Digits for linear signals and potentiometers (default 0.0) 0 = / C (temp.) digit (V/mA) (default 0) seconds (0 excludes Integral) (default 0) Auswahl Anzeige Beschreibung Beschreibung Cycle time for time-proportioning output (usually Seconds. over 10s for 18 t.c Entering 0 the cycle contactors, 1s time will be 100ms for SSR, value (default 10) declared by manufacturer for motorised valves) a. a. AL.a. Absolute related to process /Treshold alarm (default) a. b. AL.b. Band Alarm a.d.s AL.d.s. Deviation high Derivative time for seconds P.I.D t.d. (0 excludesderivative) Command output Usually ¼ (default 0) for cooling action for of integral coo cool PID Heating/Cooling time mode* Absolute with manual reset (after alarm m.r. m.r. activation, press FNC key to reset the output) ** At starting the output is desabled in case of any alarm condition. After the alarm has been solved, output will be activated only if alarm condition should occur again. 20 UR3274S - User manual UR3274S - User manual AL. Operating mode of alarm. Setpoint for alarm is SET2 a.d.i a.a.s AL.d.i. Deviation low AL.a.s. Absolute related to setpoint 1

12 Auswahl Anzeige Beschreibung Beschreibung Absolute with manual reset (after alarm activation, press FNC m.r.m. m.r.m. key to reset the output) ; status of relay stored in case of switch-off 20 c.r.a 21 s.c.a State of contact for alarm output and type of operating State of contact for alarm output in case of error State of Ld2 led OUT2 22 according to relevant LEd2 contact HY.A Alarms 23 hysteresis HYS.A digits n.o.s n.c.s n.o.r n.c.r c.o. c.c. c.o. c.c. Normally open, active at Start (default) Normally closed, active at Start Normally open, active at alarm setpoint ** Normally closed, active at alarm setpoint ** Open contact safety (default) Closed contact safety ON with open contact ON with closed contact (default) Tenth of degree for temperature sensor Digits for linear signals digits and potentiometers (default 0.0) Auswahl Anzeige Beschreibung Beschreibung seconds de.a Negative: delay at Alarm delay alarm deactivation sec. Positive: delay at alarm del.a activation (default 0) 25 p.se Allow/deny modification of setpoint values by frontal keyboard Software filter. Number of fil 26 readings to filt calculate the comparison value PV-SPV Select tun 27 type of auto-tuning tun Select operating fnc 28 mode and visualization func options Allow modification of all fre free setpoints (default) Control setpoint SPV1 pr.5 pro.s. protected Alarm setpoint SPV2 pr.a pro.a. protected Access denied to all all ALL setpoints 22 UR3274S - User manual UR3274S - User manual Number of means (Sampling frequency 15Hz) (default 10) off off Disabled (default) aut auto Automatic man man. Manual start of Tuning d.se Double setpoint d.set (default) s.se s.set Single setpoint ui 5 uis f.b.m f.b.m. Indicator only (no relay output) Function Neutral zone/ Dead band

13 Auswahl Anzeige Beschreibung Beschreibung Hide process and mai main setpoint values Domotics 1 : switch off displays and LEDs after 1.do 1.dom. 15 since last pressing of keys Domotics 2 : switch off only display after 2.do 2.dom. 15 since last pressing of keys Domotics 3 : switch off the display except 3.do 3.dom. for decimal point after 15 since last pressing of keys Single setpoint: setpoint always 5.s.u s.s.ui. visualized on display. Press to visualize process value (flashing) C C Celsius (default) Gra Type of 29 degree f f Fahrenheit Grad Set TC2 as 10s and P.B.M air Air Baud rate as (default) co.f of serial Set TC2 as 4s and P.B.M 30 communication Set TC2 as 2s and P.B.M oil Oil as coo.f H2o Water as Auswahl Anzeige Beschreibung Beschreibung Proportional band for Proportional cooling is given by the band 31 p.b.m multiplier for value of p.b. ( 15) multiplied for the cooling action value of this (default 1.00) In Heating/ Cooling PID this defines the ou.d 32 combinations ou.d 33 t.c.2 of dead band for heating and cooling action Cycle time for cooling output Filter applied to visualization of process. This filter can slow down % of p.b. value Negative value means dead band, positive value means overlapping (default 0) Seconds (default 10) Filter desabled (default) off Enable filter of first on.f order (time const. 1s). s. 2 Mean on 2 samples s. 3 Mean on 3 samples s. 4 Mean on 4 samples 34 fl.u the refresh s. 5 Mean on 5 samples of value s. 6 Mean on 6 samples on display s. 7 Mean on 7 samples in order to s. 8 Mean on 8 samples simplify the s. 9 Mean on 9 samples reading. s.10 Mean on 10 samples 24 UR3274S - User manual UR3274S - User manual 25

14 11 Tuning Tuning operation allows the setting of optimal PID s in order to assure good control action: Stable, straight-line control of temperature around setpoint, without fluctuations; quick response to deviations from setpoint caused by external noises Tuning involves calculating and setting of the following s: - Proportional band (inertia of plant; expressed as C for temperature) - Integral time (determines the time taken by the controller to remove steady-state error signals, Inertia of plant expresses as time value); - Derivative time (reaction of controller to change of measured value, usually ¼ of integral time). Setpoint value cannot be modified during Autotuning Manual start of tuning Select tun as man (manual start) Press Effect Do 1 FNC Display shows t.of 2 Display shows t.on Autotuning Parameter tun must be selected as aut. Autotuning starts automatically when the controller is switched-on or when setpoint value has been modified. Display alternates between process value and the writing tun until the function has been completed (it may take a few minutes). To interrupt the function, press and press to select t.of. 12 LATCH ON Function For application with linear potentiometers po1/po t1 ( 6K) and po2/ pot2 ( 150K) or 0 10Volt, 0/4 20mA inputs, the lower limit of scale (see 6 Lo.N.) can be set to minimum position of sensor; it is also possible to set the upper limit of scale ( 7 Hi.n.) to the max. position of sensor and this can be done directly on site. The option virtual zero (selecting u.om or u.05) allows also to fix the point where the controller will read zero (but still keeping the range of scale between Lo.N. and Hi.n. Selecting u.05 virtual zero must be reprogrammed at each starting of the controller; selecting u.om virtual zero will be stored after first calibration. To enable function LATCH ON, select chosen configuration for LAtc 1. Display will show process value and To interrupt the 3 tun alternately function press and or wait for until the function is 4 sec. press to select t.of. completed (it may take 1 a few minutes). Calibration function exits configuration mode after that the relevant has been modified. 26 UR3274S - User manual UR3274S - User manual 27

15 For calibration function follow the table below. Press Display Do Leave configuration mode. Set the sensor on Display shows cycling 1 minimum operating value process value and writing (corresponding to Lo.N.) Lac FNC SET Store minimum value. Display shows Low Store max value. Display shows HiG Store virtual zero. Display shows uir. NB: if u.05 is selected, at starting repeat calibration on point 4. Set the sensor on max. operating value (corresponding to Hi.n.) To exit standard procedure press For virtual zero settings place the sensor on zero point. FNC. To exit the procedure press FNC. Min Max Zero 13 Neutral zone Function The Neutral Zone function (which can be enabled selecting f.b.m on 28 fnc/func) allows the setting of a neutral zone control action as described in the graph. In Heating mode ( 11 reg), the operating treshold for control relay will be the value resulting from SET1 minus SET2, and the operating treshold for alarm relay will be SET1 plus SET2 (hysteresis is always set via 14 Hy.c/HYS.c). Within this band both relays are off; one relay works above this band and one relay works below. In Cooling mode ( 11 reg selected as coo/cool) the operating tresholds of both relays are reversed. Set 1 Temperature Operating zone alarm Relay Process Hysteresis (HY.C) Set 2 Set 2 Hysteresis (HY.C) Operating zone command Relay Zeit Operating zone command Relay Ex. function neutral zone for heating modality (hea/heat on reg) Standard alarm (band, deviation ) is not available in this mode. 28 UR3274S - User manual UR3274S - User manual 29

16 14 Programming module (optional) Parameters and setpoint values can be easily copied from one controller to others using the Programming module. The controller must be switched-off before entering the module. Check also entry direction (components must be turned towards front panel). Switching-on the controller, display will show m.no Press Display Do FNC shows m.ld, shows m.no The controller stores value and restarts. Select m.ld (Memo load) to store values of Programming module on the controller. Select m.no to keep values of the controller unchanged. Updating values of programming module. To update values of Programming module follow the above proceedings, selecting m.no on display, so values of programming module will not be stored on the controller 3. Enter configuration mode, modify at least one and exit Programming module with battery (optional) With the controller not connected to power supply. The programming module is equipped with an internal battery with an autonomy of about 1000 uses. Insert the programming module and press the programming buttons. When writing the s, the led turns red and on completing the procedure it changes to green. It is possible to repeat the procedure without any particular attention Loading default value This procedure makes it possible to restore factory settings of the instrument. 2 Instrument loads ly if values stored on Programming module are correct. 3 default settings and 3 If the controller does not visualize m.no at starting, this means that no to confirm resets values are stored on Programming module, but they may be copied and updated. 30 UR3274S - User manual UR3274S - User manual Press Effect Do After 5 seconds display shows 000, first digit for 5 sec. on the left is flashing 0000 on or Change the flashing Enter password: digit and move to the next one using the 999 (9999 for key. ) FNC SET

17 15 Alarm Intervention Modes Absolute Alarm or Threshold Alarm (A. A/aL.A. selection) Band Alarm (a.b./al.b. selection) Pv Alarm Spv Pv. Alarm Spv Hysteresis > 0 Time Hysteresis < 0 Alarm Spv. Time Band alarm with hysteresis. NB: hysteresis value can t be less than 0. Time Alarm output Alarm output Pv Absolute alarm with controller in heating functioning (Par.11 ReG. selected Hea/Heat) and hysteresis value greater than 0. Hysteresis > 0 Alarm Spv Command Spv Absolute alarm with controller in heating functioning (Par.11 ReG. selected coo/cool) and hysteresis value less than 0. Alarm output Absolute Alarm or Threshold Alarm Referring to Setpoint Command (a.a.s./al.a.s. selection) Command Spv Absolute alarm refers to the Hysteresis command set, with the con > 0 troller in heating functioning Alarm Spv (Par.11 ReG. selected Hea/ Heat) and hysteresis value Time greater than 0. Alarm output The command set can be changed by pressing the arrow keys on front panel or using serial port RS485 commands. 32 UR3274S - User manual Upper Deviation Alarm (a.d.s./al.d.s. selection) Pv Upper deviation alarm value Alarm Spv of alarm setpoint greater than Hysteresis 0 and hysteresis value grea > 0 Command Spv ter than 0 (Par.23 HYS. a. > 0). NB: hysteresis value can t Time be less than 0. Alarm output Pv Command Spv Alarm Spv Hysteresis > 0 Time Alarm output Upper deviation alarm value of alarm setpoint less than 0 and hysteresis value greater than 0 (Par.23 HYS. a. > 0). NB: hysteresis value can t be less than 0. UR3274S - User manual 33

18 Lower Deviation Alarm (a.d.i./al.d.i. selection) Pv Lower deviation alarm value Command Spv of alarm setpoint greater than Hysteresis 0 and hysteresis value grea > 0 ter than 0 (Par.23 HYS. a. > Alarm Spv 0). Time NB: hysteresis value can t be Alarm output less than 0. Hysteresis > 0 Pv. Alarm Spv Command Spv Time 34 UR3274S - User manual Alarm output Lower deviation alarm value of alarm setpoint less than 0 and hysteresis value greater than 0 (Par.23 HYS. a. > 0). NB: hysteresis value can t be less than Summary of Configuration s Date: Installer: Model / : System: Notes: c.out sen. d.p. Lo.L.s. Hi. s. Lo. n. Hi. n. Latc cal.o. cal.g. reg. S.c.c. Led1 Hys.c P.b. t.i. t.d. t.c. AL. c.r. a. s.c.a. Led2 Hys.a Select type of command output Sensor Type Visualization of decimal point Lower limit of setpoint Upper limit of setpoint Lower limit only for V/I V/mA Upper limit only for V/I V/mA Latch Function set calibration Gain calibration Type of action Type of contact for control output in case of anomaly Select state of OUT1 Hysteresis dead/band Proportional band Integral time Derivative time Proportional cycle time Type of alarm Contact alarm OUT State of contact for alarm output in case of anomaly State of the LED Alarms hysteresis o1.o2. tc. k off Heat c.o. c.c AL.A. n.o.s. c.o. c.c. 0 UR3274S - User manual 35

19 del.a delay alarm 0 p.se. Set protection free filt. Software filter 10 tune Type of autotuning off func. Type of operating d.set Grad. Degrees selection C coo.f. Cooling fluid air p.b.m. Proportional band multiplier 1.00 ou.db. Overlapping / dead band 0 t.c. 2 Cycle time 2 10 flt.u Visualization Filter off Notes 36 UR3274S - User manual UR3274S - User manual 37

20 38 UR3274S - User manual

21 Wachendorff Prozesstechnik GmbH & Co. KG Industriestrasse 7 D Geisenheim Tel: +49 (0) / Fax: +49 (0) / efdi@wachendorff.de Copyright by Wachendorff Prozesstechnik GmbH & Co. KG

The range of ATR243 controllers comes in three versions. Refer to the table below to easily select your preferred model.

The range of ATR243 controllers comes in three versions. Refer to the table below to easily select your preferred model. Summary 1 Introduction... 3 2 Model Identification... 3 3 Technical Data... 4 3.1 General Features... 4 3.2 Hardware Features... 4 3.3 Software Features... 5 4 Dimensions and Installation... 5 4.1 Panel

More information

02/11/2015

02/11/2015 CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint

More information

02/11/2015

02/11/2015 MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS

More information

Controller URDR0001 User manual Version 1.0

Controller URDR0001 User manual Version 1.0 Controller URDR0001 User manual Version 1.0 Summary 1 Safety instructions...5 1.1 General instructions...5 1.2 Intended Usage...5 1.3 Qualified personnel...6 1.4 Remaining hazards...6 1.5 CE Conformity...6

More information

I/A Series 716C 1/16 DIN Temperature Controller

I/A Series 716C 1/16 DIN Temperature Controller Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of

More information

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1 VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1. INTRODUCTION This manual contains information for the installation and operation and tuning of our Vertex VT10 series self-tuning

More information

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Instruction Manual Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Manual PCT30006, Revision 9/20/2016 The PCT30006 control enclosure incorporates

More information

ISO-plus-RS4 ISO-plus-CAN

ISO-plus-RS4 ISO-plus-CAN ISO-plus-RS4 ISO-plus-CAN User manual Table of contents 1 Safety standards...5 2 Model identification...5 3 Technical data...5 3.1 Main features...5 3.2 Hardware Features...6 3.3 Software features...6

More information

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Instruction Manual Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Manual PCT-3000 Revision 9/2014 The PCT-3000 series control console incorporates

More information

Universal display DA9602

Universal display DA9602 Universal display DA9602 Version: 22.02.2013 Copyright by Wachendorff Prozesstechnik GmbH & Co. KG, Industriestraße 7, D-65366 Geisenheim, Tel.: +49-6722/9965-20, Fax: -78. All Information without warranty,

More information

Series Temperature Controller Instruction Sheet

Series Temperature Controller Instruction Sheet Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep

More information

UDC 700 Universal Digital Controllers and Indicator Specifications

UDC 700 Universal Digital Controllers and Indicator Specifications UDC 700 Universal Digital Controllers and Indicator Specifications 51-52-03-28 August 2002 Overview The UDC 700 is a 1/32 DIN (49 x 25 mm) controller which combines a high degree of technology and quality

More information

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Universal controller for panel mounting Models CS6S, CS6H, CS6L Accessories Universal controller for panel mounting Models CS6S, CS6H, CS6L WIKA data sheet AC 85.08 Applications Plant and industrial furnace construction Process engineering Plastics technology and processing

More information

UR3274 Controller User manual. Version 1.0

UR3274 Controller User manual. Version 1.0 UR3274 Controller User manual Version 1.0 Summary 1 Safety instructions... 5 1.1 General instructions... 5 1.2 Intended Usage... 6 1.3 Qualified personnel... 6 1.4 Remaining hazards... 6 1.5 CE Conformity...

More information

ATR 401. Regolatore Controller Manuale Installatore User manual

ATR 401. Regolatore Controller Manuale Installatore User manual ATR 401 Regolatore Controller Manuale Installatore User manual Summary Page 1 Introduction 4 2 Model Identifi cation 4 3 Technical data 5 3.1 General data 5 3.2 Hardware data 5 3.3 Software data 6 4 Dimensions

More information

ATR 171. Regolatore Controller Manuale Installatore User manual

ATR 171. Regolatore Controller Manuale Installatore User manual ATR 171 Regolatore Controller Manuale Installatore User manual Summary Page 1 Introduction 4 2 Model Identifi cation 4 3 Technical Data 5 3.1 General data 5 3.2 Hardware data 5 3.3 Software data 6 4 Dimensions

More information

7EF/7HF/7EC/7ES Temperature Controllers

7EF/7HF/7EC/7ES Temperature Controllers 7EF/7HF/7E/7ES Temperature ontrollers Dual 4 Digit LED Display Universal Input (6 T/, RTD, mv, V, ma) Autotuning NEMA 4X 100 to 240 Vac Switching Power Supply Algorithms for Heat or Heat/ool ontrol 2 Independent

More information

OVEN INDUSTRIES, INC.

OVEN INDUSTRIES, INC. OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

Table of Contents SECTION PAGE

Table of Contents SECTION PAGE Table of Contents SECTION PAGE SECTION 1 INTRODUCTION................... 1.1 Description.............................. 1.2 Features................................ 1.3 Models.................................

More information

Nov 08 PRODUCT SPECIFICATION SHEET

Nov 08 PRODUCT SPECIFICATION SHEET Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 Nov 08 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN

More information

TC515 and TC600 Installation Manual. a Winters company

TC515 and TC600 Installation Manual. a Winters company THERMOLINE TEMPERATURE CONTROLLERS TC515 and TC600 Installation Manual a Winters company Guarantee 12 months Congratulations on the purchase of this new product. Special care with the design, workmanship

More information

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 4/01 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1000 and UDC1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

VT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL

VT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL Thermocouple Type BS4937 (IEC584-3): Outer / + / - BS1843 (Old UK Standard) Outer / + / - US Outer / + / - J : Iron / Copper-Nickel Black / Black / White Black / Yellow / Blue Black / White / Red VT4810

More information

TEMPERATURE CONTROL MODULE MODEL R3-TC2

TEMPERATURE CONTROL MODULE MODEL R3-TC2 INSTRUCTION MANUAL R3-TC2 TEMPERATURE CONTROL MODULE MODEL R3-TC2 CONTENTS BEFORE USE... 2 POINTS OF CAUTION... 2 COMPONENT IDENTIFICATION... 2 INSTALLATION... 2 EXTERNAL DIMENSIONS unit: mm (inch)...

More information

eed quality electronic design USER s MANUAL

eed quality electronic design USER s MANUAL eed quality electronic design www.dem-it.com eed www.qeed.it info@qeed.it ANALOG SIGNAL DISPLAY Q-DISP-T USER s MANUAL The displays Q-DISP-T, prepared for mounting on the back panel, 96x48mm, will allow

More information

R1000 / R1040 / R1080

R1000 / R1040 / R1080 R1000 / R1040 / R1080 1 Zone Temperature Controller: Heat-only Heating-off-cooling Three-point stepping DIN-Format: 96mm x 96mm / 48mm x 96mm / 96mm x 48mm Description and operating manual ELOTECH Industrieelektronik

More information

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE Release January 2001 CONTENTS 1.0 GENERAL CHARACTERISTICS... 4 1.1 MAIN CHARACTERIS TICS... 4 2.0 USER INTERFACE (CODE C5121230)... 5 2.1 DISPLAY... 5 2.2 MEANING OF THE LEDS...

More information

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03 Digital Controller A 96 x 96-mm (DIN) Digital Process Controller Optimum PID control with feed-forward control circuitry. High accuracy (+0.3% FS +1 digit max.). Replaceable Output Units. Models with communications

More information

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number ST71-KHJV.3 Temperature controller Order number 921.8 Wiring diagram Product description The switching outputs of the thermal controller can be programmed as -two-point controller with alarm -three-point

More information

Dixell Installing and Operating Instructions release 7.0

Dixell Installing and Operating Instructions release 7.0 XR160C - XR160D - XR170C - XR170D - XR162C - XR172C CONTENTS 1. GENERAL WARNING 2 1.1 Please read before using this manual 2 1.2 Safety Precautions 2 2. GENERAL DESCRIPTION 2 3. CONTROLLING LOADS 2 3.1

More information

F4 Process Controller Installation and Operation Guide

F4 Process Controller Installation and Operation Guide F4 Process Controller Installation and Operation Guide 1.Introduction 1.1.Highlight Features Space saving, only 55mm panel depth required Higher sampling rate (1mS) results in better control performance

More information

ST Wiring diagram. Product description. Standard temperature controller. Order number

ST Wiring diagram. Product description. Standard temperature controller. Order number ST64-31.10 Standard temperature controller Order number 900197.007 Old Id.Nr.: 386169 Wiring diagram Product description The controller ST64-31.10 was developed for simple thermostatic controls. The round

More information

Installation Manual Tracker 221

Installation Manual Tracker 221 Installation Manual Tracker 221 KSR KUEBLER AG Im Kohlstatterfeld 17 D-69439 Zwingenberg / Germany www.ksr-kuebler.com Contents About this Installation Manual...4 Description Tracker 220-series...4 Installing

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

Temperature-Relay TR210

Temperature-Relay TR210 Operating instructions Temperature-Relay TR210 Page 1 of 24 Table of contents 1. Application and Short description... 3 2. Overview of functions... 3 3. Connection Plan... 3 4. Display and operation parts...

More information

INSTALLATION & USER MANUAL

INSTALLATION & USER MANUAL INSTALLATION & USER MANUAL HC Digital Automatic Humidistat (Y3760) CONTROLS 506808-01 3/2016 Supersedes 6/2011 picture goes here THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE NOTICE

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors Product sheet SN1.402 Type CDR-AL CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors CDR-AL sensors are designed to detect carbon dioxide concentration and temperature in the room spaces. The units

More information

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0) Serie 5000 Tel. +1 (0)5 222 Fax +1 (0)5 222 12 PRODUCT INTRODUCTI PRODUCT INTRODUCTI 5 Series programmable temperature controller is FineTek's mid-range series of controllers. It uses a 12bit analog /

More information

ER52 - Evaporator Controller

ER52 - Evaporator Controller ER52 - Evaporator Controller Electronic Refrigeration Line Product Bulletin Devices are standalone digital controller for static or ventilated refrigeration units working at positive temperatures. They

More information

TLK39 MICROPROCESSOR-BASED DIGITAL ELECTRONIC CONTROLLER. OPERATING INSTRUCTIONS Vr (ENG) - cod.: ISTR 06262

TLK39 MICROPROCESSOR-BASED DIGITAL ELECTRONIC CONTROLLER. OPERATING INSTRUCTIONS Vr (ENG) - cod.: ISTR 06262 TLK39 MICROPROCESSOR-BASED DIGITAL ELECTRONIC CONTROLLER OPERATING INSTRUCTIONS Vr. 02.1 (ENG) - cod.: ISTR 06262 FOREWORD: This manual contains the information necessary for the product to be installed

More information

OPERATING INSTRUCTIONS Vr. 02 (ENG) - cod.: ISTR 06261

OPERATING INSTRUCTIONS Vr. 02 (ENG) - cod.: ISTR 06261 TLK 38 MICROPROCESSOR-BASED DIGITAL ELECTRONIC CONTROLLER OPERATING INSTRUCTIONS Vr. 02 (ENG) - cod.: ISTR 06261 FOREWORD: This manual contains the information necessary for the product to be installed

More information

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e C C1 C2 AL1 AL2 AL3 Micro-controller X Model: PXR4/5/9 PXR SEL Operation Manual ECNO:46e Table of Contents Part Names and Functions... 6 Operations... 7 2-1 Parameter list... 7 2-2 Basic operations...

More information

User manual FRONTAL IP65 1 UNIVERSAL ANALOGIC INPUT 2 RELAY OUTPUTS. 2 TRANSITOR OUTPUTS (PNP) SSR 1 ANALOGIC OUTPUT 0/10V, 4/20mA 2 DIGITAL INPUTS

User manual FRONTAL IP65 1 UNIVERSAL ANALOGIC INPUT 2 RELAY OUTPUTS. 2 TRANSITOR OUTPUTS (PNP) SSR 1 ANALOGIC OUTPUT 0/10V, 4/20mA 2 DIGITAL INPUTS CONTROLLER DIS48-PLUS PROGRAMMING ALSO THROUGH SMARPHONE 1 UNIVERSAL ANALOGIC INPUT 0/10V, 4/20mA, Pt100, Thermocuple mv, ntc10k, PTC1K... 2 DIGITAL INPUTS 1 1 2 2 TIMERS FRONTAL IP65 POWER SUPPLY 24..

More information

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with

More information

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs User Manual Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-03 and 89800-04 THE STANDARD IN PRECISION MEASUREMENT Table of Contents

More information

TER Active Room Temperature Sensor (Controller),

TER Active Room Temperature Sensor (Controller), Product sheet SN1.415 Type TER TER Active Room Temperature Sensors (Controllers) The TER active sensors are designed to detect temperature in the room spaces. The TER sensors have linear 0..10V signals

More information

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF: EC 6-295P220S001 smart guide ON-OFF digital controller for ventilated refrigerating units Version 1.01 of 15 th March 2005 File ec6295p220s001_eng_v1.01.pdf PT EVCO S.r.l. Via Mezzaterra 6, 32036 Sedico

More information

RS Pro Infrared Temperature Sensor

RS Pro Infrared Temperature Sensor Instruction Manual RS Pro Infrared Temperature Sensor Stock Number: 161-8103 Introduction The RS Pro Infrared Temperature Sensor is a device for measuring the temperature of the surface of a solid or liquid

More information

TLK 43 MICROPROCESSOR-BASED DIGITAL ELECTRONIC CONTROLLER. OPERATING INSTRUCTIONS Vr. 02 (ENG) - cod.: ISTR 6267

TLK 43 MICROPROCESSOR-BASED DIGITAL ELECTRONIC CONTROLLER. OPERATING INSTRUCTIONS Vr. 02 (ENG) - cod.: ISTR 6267 TLK 43 MICROPROCESSOR-BASED DIGITAL ELECTRONIC CONTROLLER OPERATING INSTRUCTIONS Vr. 02 (ENG) - cod.: ISTR 6267 FOREWORD: This manual contains the information necessary for the product to be installed

More information

ELK 38 MICROPROCESSOR-BASED DIGITAL ELECTRONIC CONTROLLER. OPERATING INSTRUCTIONS Vr. 02 (ENG) - cod.: ISTR 06261

ELK 38 MICROPROCESSOR-BASED DIGITAL ELECTRONIC CONTROLLER. OPERATING INSTRUCTIONS Vr. 02 (ENG) - cod.: ISTR 06261 ELK 38 MICROPROCESSOR-BASED DIGITAL ELECTRONIC CONTROLLER OPERATING INSTRUCTIONS Vr. 02 (ENG) - cod.: ISTR 06261 INDEX 1 INSTRUMENT DESCRIPTION 1.1 GENERAL DESCRIPTION 1.2 FRONT PANEL DESCRIPTION 2 PROGRAMMING

More information

EM300(LX) electronic digital indicator. Alarm (IF PRESENT) ON for active alarm; blinking for silenced alarm that is still present

EM300(LX) electronic digital indicator. Alarm (IF PRESENT) ON for active alarm; blinking for silenced alarm that is still present EM3(LX) GB code 9IS4349 rel. 66 electronic digital indicator USER INTERFACE The user has a display and four buttons for controlling instrument status and programming. BUTTONS AND MENUS ACCESSING UP Button

More information

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11 Table of Contents 1. OVERVIEW... 3 2. SYSTEM LAYOUT... 4 3. SPECIFICATIONS... 8 3.1 SYSTEM COMPONENTS...9 3.2 PLC INPUTS AND OUTPUTS...9 3.3 FUNCTION KEYS...10 3.4 DEFAULT SET POINTS AND TIMERS...10 4.

More information

Mark 25 Ultrapure Water Conductivity Analyzer

Mark 25 Ultrapure Water Conductivity Analyzer Martek Instruments, Inc. Mark 25 Ultrapure Water Conductivity Analyzer Instruction Manual WARRANTY POLICY Unless otherwise stated, MARTEK INSTRUMENTS, INC. warrants this equipment to be free from defects

More information

ER65 - Mini Rack Controller Electronic Refrigeration Line

ER65 - Mini Rack Controller Electronic Refrigeration Line PB_ER65_ 00 ER65 - Mini Rack Controller Electronic Refrigeration Line Device is a multi-stage digital controller. It is typically applied to small refrigeration rack units piloting compressors or condenser

More information

Oakton TEMP 9500 Advanced Multiparameter Controller

Oakton TEMP 9500 Advanced Multiparameter Controller Oakton TEMP 9500 Advanced Multiparameter Controller Models: 89800-03 & 89800-04 Oakton Instruments 625 E Bunker Ct. Vernon Hills, IL 60061, USA 1-888-4OAKTON (1-888-462-5866) info@4oakton.com Contents

More information

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422 ºF / º C Rooftop Thermostat Controller Model TRT2422 Description The TRT2422 is a combination controller and thermostat with a built-in scheduler, which is designed for simple and accurate control of single

More information

ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER

ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER AI-208 (V7.6) User Manual I. Model Code Symbol The type of AI-208 is made up of 4 parts: AI-208 A G L2 Part 1 (Series) Part 2 (Size) Part 3 (Oupt) Part 4

More information

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100 INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller 1 GCS-00 No.GCS1E 200.11 To prevent accidents arising from the use of this controller, please ensure the operator receives this manual.

More information

User s Guide CN616A. Universal 6 Channel ¼ DIN Process Controller. Shop online at omega.com

User s Guide CN616A. Universal 6 Channel ¼ DIN Process Controller. Shop online at omega.com TM User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info CN616A Universal 6 Channel ¼ DIN Process Controller omega.com info@omega.com U.S.A. Headquarters:

More information

Software Version 2.01 LEVEL MONITOR MODEL 220

Software Version 2.01 LEVEL MONITOR MODEL 220 Software Version 2.01 LEVEL MONITOR MODEL 220 19 April 2000 CONTENTS 1. Introduction 1 1.1 Model Number Designation 2 1.2 Intrinsic Safety Considerations 3 2. Specification 4 3. Operation 6 3.1 Display

More information

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1- DPR-45 User Manual V-2.0 (2..206) DPR-45 TEMPERATURE PROTECTION RELAY PT00 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT 9-50VDC SUPPLY DESCRIPTION DPR-45 is a precision unit designed for the temperature

More information

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring 1. GENERAL DESCRIPTION Model XWA11V-KIT, 100x64 mm format, is a microprocessor based light and alarm management controller,

More information

TEMPERATURE CONTROLLER (STANDARD MODEL)

TEMPERATURE CONTROLLER (STANDARD MODEL) OPERATING MANUAL TEMPERATURE CONTROLLER (STANDARD MODEL) 689-0000 689-0005 Barnant Company 28W092 Commercial Avenue Barrington, Illinois U.S.A. 60010-2392 (847) 381-7050 (847) 381-7053 (Fax) 800-637-3739

More information

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma) TEMPERATURE CONTROLLER DIN-sized (96 x 96-mm) Temperature Controller Featuring Advanced PID Control and Heater Burnout Detection Advanced PID control with two degrees of freedom to improve stability and

More information

Electronic Temperature Controller 70304,

Electronic Temperature Controller 70304, Electronic Temperature Controller 70304, 70304.2 Instruction Manual Version 1.00.01 List of content 1 General information... 4 2 Declaration of conformity... 4 3 Safety instructions... 5 4 Warranty...

More information

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support. AutomationDirect 1/16 DIN Series Technical Support We strive to make our manuals the best in the industry. We rely on your feedback to let us know if we are reaching our goal. If you cannot find the solution

More information

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB Summary 1 CONNECTIONS... 3 1.1 TEMPERATURE PROBES...3 1.2 LOW VOLTAGE DIGITAL INPUTS...3 1.3 LIVE DIGITAL INPUTS...4 1.4 RELAY OUTPUTS...5 2 POWER SUPPLY... 6 3 SERIAL CONNECTIONS... 6 4 SOFTWARE... 7

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations. 1 P age Ezeio v9-120317 Eze Cloud Based Monitoring Systems. Created by Intech Instruments Ltd December 2014 Important Supplementary Manual to the main Ezeio manual. Ezeio Controller and the 2400-A16 input

More information

INSTRUCTION MANUAL Micro-computer based digital indicating controller

INSTRUCTION MANUAL Micro-computer based digital indicating controller INSTRUCTI MANUAL Micro-computer based digital indicating controller TP4A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution

More information

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller PB_ER65-DRW_ 202 ER65-DRW Controller Heating Applications Product Bulletin The controller is a digital device for domestic or residential heating units. It covers water and air heating applications. All-in-one

More information

TLI40 MICROPROCESSOR-BASED DIGITAL ELECTRONIC INDICATOR. OPERATING INSTRUCTIONS Vr. 03 (ENG) - cod.: ISTR-MTLI40ENG3. ASCON TECNOLOGIC s.r.l.

TLI40 MICROPROCESSOR-BASED DIGITAL ELECTRONIC INDICATOR. OPERATING INSTRUCTIONS Vr. 03 (ENG) - cod.: ISTR-MTLI40ENG3. ASCON TECNOLOGIC s.r.l. TLI40 MICROPROCESSOR-BASED DIGITAL ELECTRONIC INDICATOR OPERATING INSTRUCTIONS Vr. 03 (ENG) - cod.: ISTR-MTLI40ENG3 INDEX 1 INSTRUMENT DESCRIPTION 1.1 GENERAL DESCRIPTION 1.2 FRONT PANEL DESCRIPTION 2

More information

Microprocessor-based digital electronic controller TLK 38

Microprocessor-based digital electronic controller TLK 38 1. General description is a single loop digital microprocessor-based controller, with ON/OFF, Neutral Zone ON/ OFF, PID single action, PID dual action (direct and reverse) control and with AUTO-TUNING

More information

Pump-Down Controller MODEL 4052

Pump-Down Controller MODEL 4052 Pump-Down Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4052 Pump-Down

More information

User Manual. Dryer Controller M720

User Manual. Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009

More information

UDC100 Universal Digital Controller Specifications

UDC100 Universal Digital Controller Specifications UDC100 Universal Digital Controller Specifications 51-52-03-29 November 1999 Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines

More information

Installer Manual KNX Touchscreen Thermostat

Installer Manual KNX Touchscreen Thermostat Installer Manual 02952 KNX Touchscreen Thermostat Index GENERAL FEATURES AND FUNCTIONALITY from page 5 ETS PARAMETERS AND COMMUNICATION OBJECTS from page 7 COMMUNICATION OBJECTS GENERAL FEATURES AND FUNCTIONALITY

More information

CT224 Setup Tutorial

CT224 Setup Tutorial CT224 Setup Tutorial Table of Contents 1. Introduction 2. Configuring Controller for Operation A. Example 1 Over Temp Operation with Hysteresis @ 5º F. B. Example 2 Under Temp Operation with Hysteresis

More information

SCAN20 Series Gas Detection Controller

SCAN20 Series Gas Detection Controller SCAN20 Series Gas Detection Controller USER S MANUAL Code Number 2071 1022 SCAN20 USER S MANUAL Code no. 2071 1022 Page 1/14 Foreword This manual is made for SCAN20 Controllers equipped with the software

More information

Pump-Up Controller MODEL 4062

Pump-Up Controller MODEL 4062 Pump-Up Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4062 Pump-Up

More information

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

Modular Standard HP Chiller 1/4 screw compressor with Carel driver Program for pco¹ pco 2 and pcoc Modular Standard HP Chiller 1/4 screw compressor with Carel driver Manual version 1.0 25 September 2003 Program code: FLSTDmMSDE Do we want you to save you time and money?

More information

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER Thank you for your purchase of our Microcomputer based Temperature Indicating Controller. This manual contains instructions

More information

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs User Manual Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-13 and 89800-14 THE STANDARD IN PRECISION MEASUREMENT Table of Contents

More information

DIGITAL METERS Large Display Temperature Meters Instruction Manual

DIGITAL METERS Large Display Temperature Meters Instruction Manual DIGITAL METERS Large Display Temperature Meters PD755 PD756 PD757 Handles Thermocouple & RTD Inputs with Simplicity J, K, T, E, R, & S Thermocouples 100 Ω Platinum RTD (0.00385 or 0.00392 curve) Large

More information

User s Guide. CN616 Series 1 4 DIN Economical 6-Zone PID Temperature Controllers. Shop online at omega.com SM

User s Guide. CN616 Series 1 4 DIN Economical 6-Zone PID Temperature Controllers. Shop online at omega.com SM User s Guide Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info CN616 Series 1 4 DIN Economical 6-Zone PID Temperature Controllers omega.com info@omega.com

More information

Oxygen (O2) Single-Point Gas Detection System

Oxygen (O2) Single-Point Gas Detection System Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity

More information

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary

More information

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440) Safety Temperature Limiter STL 50 Certified to DIN EN 14597 (replaces DIN 3440) Features M For use as: STB Protection - temperature limiter ASTB Exhaust gas - protection - temperature limiter STW Protection

More information

CM 16. Temperature controllers with compact dimensions. Manual 42/61-72 EN Rev. 01

CM 16. Temperature controllers with compact dimensions. Manual 42/61-72 EN Rev. 01 CM 16 Temperature controllers with compact dimensions Manual 42/61-72 EN Rev. 01 Table of contents Page Remarks... 2 Installation and commissioning 1. Identifying the instrument... 3 2. Selecting installation

More information

SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1

SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1 SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1 Jun. 2007 Auber Instruments, 730 Culworth, Alpharetta, GA 30022 www.auberins.com e-mail: auberins@gmail.com Tel: 404-291-6298 WARNING

More information

Model 96VTR ¼ DIN Process Controller

Model 96VTR ¼ DIN Process Controller 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 96VTR Product Info Page INSTRUCTION MANUAL Model 96VTR ¼ DIN

More information

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS CONTENTS 1. INTRODUCTION... 5 2. WARNINGS... 6 3. GENERAL DESCRIPTION... 7 4. INSTALLATION... 8 5. LUMINOUS INDICATORS AND COMMANDS... 9 6. DIP-SWITCH

More information

Specification , July 2015

Specification , July 2015 Technical Information PrecisionLine Controllers EDC21 / EDC22 / EDC23 EASYSET DIGITAL CONTROLLERS Specification 51-52-3-48, July 215 Introduction The EDC21, EDC22 and EDC23 controllers provide precise

More information

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting Temperature Controller General Description The is a high performance 3 nd DI controller that has been specifically designed for applications where panel space is critical. Though small in size, this controller

More information

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1 Model TRO24T4XYZ1 Description The TRO24T4XYZ1 is a combination controller and thermostat. The VAV Thermostat Controller is designed for simple and accurate control of any variable air volume box in a number

More information

Nokeval. No Manual. Model 2026 Totalizer / Batch controller for analog inputs

Nokeval. No Manual. Model 2026 Totalizer / Batch controller for analog inputs No 00 Nokeval Manual Model 0 Totalizer / Batch controller for analog inputs Contents Rate / Batch controller 0 for analog inputs... Dimensions... Front panel indicators and buttons... Configuration...

More information

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail Temperature Controller General Description The is a socket mounting type temperature controller and is available for mounting inside the panel or by easily mounting on DI rail. The has features such as

More information

TH-TD Advanced MICROPROCESSER BASED TEMPERATURE REGULATOR. INSTRUCTION MANUAL Rel. 02 (ENG) DATASENSOR S.p.A.

TH-TD Advanced MICROPROCESSER BASED TEMPERATURE REGULATOR. INSTRUCTION MANUAL Rel. 02 (ENG) DATASENSOR S.p.A. TH-TD Advanced MICROPROCESSER BASED TEMPERATURE REGULATOR INSTRUCTION MANUAL Rel. 02 (ENG) DATASENSOR S.p.A. FOREWORD: This manual contains the information necessary for the product to be installed correctly

More information