Signature Series Component

Size: px
Start display at page:

Download "Signature Series Component"

Transcription

1 Signature Series Component Installation Manual P/N 7097 Rev.0 06DEC99

2 DEVELOPED BY COPYRIGHT NOTICE Edwards Systems Technology 6 Parkland Drive Sarasota, FL (9) Copyright Edwards Systems Technology This manual and the products it describes are copyrighted by Edwards Systems Technology (EST). You may not reproduce, translate, transcribe, or transmit any part of this manual without express, written permission from EST. This manual contains proprietary information intended for distribution to authorized persons or companies for the sole purpose of conducting business with Edwards Systems Technology, Inc. If you distribute any information contained in this manual to unauthorized persons, you have violated all distributor agreements and we may take legal action. CREDTIS This manual was designed and written by EST Technical Services - Documentation Department, Sarasota. REVISION INFORMATION The last revisions to this manual were made 06DEC99.

3 Content -CTM City Tie Module SIGA-70(L) Fire Alarm Station SIGA-70P -Stage Fire Alarm Station SIGA-78 Double Action Fire Alarm Station SIGA-AB Detector Sounder Base SIGA-CC Single Input Signal Module SIGA-CC Dual Input Signal Module SIGA-CR Control Relay Module SIGA-CRR Control Relay Reversing Module SIGA-CT Single Input Module SIGA-CT Dual Input Module SIGA-DG Detector Guard SIGA-DGS Surface Adapter for use with the SIGA-DG Detector Guard SIGA-DH Duct Detector Housing Assembly SIGA-DMP Duct Mounting Plate SIGA-DTS Duct Detector Test Station SIGA-HFS Fixed-Temperature Heat Detector SIGA-HRS Fixed-Temperature/Rate-of-Rise Heat Detector SIGA-HRSI Grade Heat Detector SIGA-IB Detector Base SIGA-IB Detector Base SIGA-IM Isolator Module SIGA-IPHS(B) D Multisensor Smoke Detector SIGA-IS Ionization Smoke Detector SIGA-LED Remote LED Alarm Indicator SIGA-MAB Class A/B Input/Output Module SIGA-MB Transponder Mounting Bracket SIGA-MCC Single Input Signal Module SIGA-MCC Dual Input Signal Module SIGA-MCR Control Relay (Dry) Module SIGA-MCRR Control Reversing Relay Module SIGA-MCT Dual Input Module SIGA-MM Monitor Module SIGA-MP Mounting Plate SIGA-MP Mounting Plate SIGA-MPL Mounting Plate SIGA-PHS D Multisensor Smoke Detector SIGA-PS Photoelectric Smoke Detector SIGA-RB Detector Base SIGA-RB Detector Base SIGA-SB Detector Base SIGA-SB Detector Base SIGA-TS -inch Box Trim Skirt / Ring SIGA-UIOR Universal Input/Output Motherboard SIGA-UIO6(R) Universal Input/Output Motherboard SIGA-UM Universal Class A/B Module SIGA-WTM Waterflow/Tamper Module SIGI-7 Breakglass Station SIGI-IBS Detector Base Signature Series Component Installation Manual i

4 Important Information Limitation of liability This product has been designed to meet the requirements of NFPA Standard 7, 99 Edition; Underwriters Laboratories, Inc., Standard 86, 7th Edition; and Underwriters Laboratories of Canada, Inc., Standard ULC S7 Installation in accordance with this manual, applicable codes, and the instructions of the Authority Having Jurisdiction is mandatory. EST shall not under any circumstances be liable for any incidental or consequential damages arising from loss of property or other damages or losses owing to the failure of EST products beyond the cost of repair or replacement of any defective products. EST reserves the right to make product improvements and change product specifications at any time. While every precaution has been taken during the preparation of this manual to ensure the accuracy of its contents, EST assumes no responsibility for errors or omissions. FCC warning This equipment can generate and radiate radio frequency energy. If this equipment is not installed in accordance with this manual, it may cause interference to radio communications. This equipment has been tested and found to comply within the limits for Class A computing devices pursuant to Subpart B of Part of the FCC Rules. These rules are designed to provide reasonable protection against such interference when this equipment is operated in a commercial environment. Operation of this equipment is likely to cause interference, in which case the user at his own expense, will be required to take whatever measures may be required to correct the interference. ii Signature Series Component Installation Manual

5 Document History Signature Series Component Installation Manual P/N 7097 Revision Status Revision Date Reason For Change.0 FEB97 Initial Release.0 06DEC99 Add the following installation sheets to the manual; AB, CRR, MAB, MCR, MCRR, MCC, MCC, MCT, UIO, and UIO6(R). Remove SIGA-RB Sounder Base. Signature Series Component Installation Manual iii

6 iv Signature Series Component Installation Manual

7 WIRING VDC out to next device (if required) + Alarm Wiring VDC from panel DATA IN SINGLE INPUT SIGNAL MODULE CTM + + Master Box Municipal Circuit + DATA OUT Notes VDC from panel DATA IN VDC out to next device (if required) DATA OUT SINGLE INPUT SIGNAL MODULE 0 9 Supervisory Wiring -CTM Master Box Municipal Circuit 00mA into a. trip coil max., loop resistance =. ) Circuit is supervised for OPENS. Circuit not supervised for OPENS and is not power limited. ) The Single Input Signal Module and the -CTM must be installed in the same room within three feet of each other. PRODUCT INFORMATION -CTM Description The City Tie Module (-CTM) is designed for use with Signature controllers. The -CTM is an interface between a Single Input Signal Module or a Dual Input Signal Module and a Master Box. It provides off premise signal transmission for systems which must comply with the provisions of the NFPA. The -CTM is used to activate a local energy fire alarm box, which provides a VDC alarm signal which is current limited at 00 ma. SPECIFICATIONS Power Municipal Box Operation Max. Wiring Resistance Trip Current Max. Current Standby Current Mounting Nominal 00mA Nominal VDC 00mA into. Coil 00mA 0mA Single Gang Box INSTALLATION SHEET: INSTALLATION SHEET P/N: 7096 FILE NAME: 7096.CDR REVISION LEVEL:. APPROVED BY: SJ DATE: 08//97 CREATED BY: MR A UNIT OF GENERAL SIGNAL GS BUILDING SYSTEMS CORPORATION -CTM City Tie Module GS BUILDING SYSTEMS CORPORATION 6 Parkland Drive 6 6th Street East Sarasota, FL Owen Sound, ON, Canada

8

9 Description Device addressing LEDs Mounting PRODUCT INFORMATION The Fire Alarm Station, 70 Series, is a component of the Signature Series. It is a normally-open, dry contact signal initiating device that requires only one action by the user in order to initiate an alarm. The single input module mounted to the back of the unit supervises the station and sends an alarm signal to the loop controller when the switch is closed (i.e. when the handle is pulled). One device address is required. The loop controller assigns an address to the station automatically. A custom address can be assigned to the station via laptop computer; no addressing switches are used. Diagnostic LEDs provide visible indication of the status of the station, when the unit is removed from the electrical box. Normal: Green LED flashes Alarm/active: Red LED flashes The terminal blocks will accept AWG,, 6, or 8 wire (.,.,.0, or 0.7 sq mm ). Sizes 6 and 8 are preferred. System controller capability The 70 Series requires the Signature Loop Controller. Personality code : N/O alarm latching The 70 Series is factory assigned personality code which configures the station for alarm latching operation. When the pull lever is activated, an alarm signal is sent to the Loop Controller and the alarm condition is latched at the fire alarm station. WARNINGS SPECIFICATIONS Construction: Cast zinc with steel backplate Operation mechanism: Single action, pull lever Operating voltage range: Vdc Standby current: 0 A Activated current: 00 A Operating temperature range: to 0 F (0 to 9 C) Operating humidity range: 0-9%RH Replacement glass rods USA, P/N 76-GLR (pkg 0 rods) CAN, P/N 76 (pkg rods) Storage temperature range: - to 0 F (-0 to 60 C) Compatible electrical boxes North American: -/ in (6 mm) deep -gang box Standard: in square box -/ in (8 mm) deep with -gang cover Special order surface mount boxes 79-0: Cream enamel finish 79-: Red enamel finish Shipping weight:. lbs (0. kg) FIRE ALARM PRODUCT DIAGRAM LOCAL ALARM This device will NOT operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. PULL IN CASE OF FIRE PULL IN CASE OF FIRE 70 70L INSTALLATION SHEET SIGA-70 and SIGA-70L Fire Alarm Stations INSTALLATION SHEET P/N: 8708P REVISION LEVEL: 6.0 DATE: 0JUN99 FILE NAME: 8708P.CDR APPROVED BY: B. Right CREATED BY: D. Chinell TM EDWARDS SYSTEMS TECHNOLOGY 6 Parkland Drive Sarasota, FL USA 6 6th Street East Owen Sound, Ontario Canada NK P8

10 INSTALLATION INSTRUCTIONS ) The pull station is shipped from the factory complete with a single input module attached. The electronic module contains no userserviceable parts and should NOT be disassembled. ) Open the pull-station by using a flat blade screwdriver to twist the cover release screw counterclockwise while pulling the cover away from its backplate. ) Verify that all field wiring is free of opens, shorts, and ground faults. ) Make all wiring connections as shown in the diagram. ) Write the address assigned to the pull-station on the label provided and apply the label to the pull-station. Peel off the removable serial number label from the pull-station and apply it to the appropriate location in the Serial Number Logbook. 6) Using the two 6- x /8 in (6 mm) machine screws provided, mount the pull-station to the electrical box. 7) Pull the glass rod release lever and install the glass rod through the mounting bracket on the front of the pull-station. Set the toggle switch to the NORMAL position and snap the cover into its locked position. Compatible electrical box NORMAL LIFT Back plate Toggle switch Glass rod release lever Cover release screw WIRING DIAGRAM Notes [] Refer to Signature Loop Controller Installation Sheet for wiring specifications. All wiring is power-limited and supervised. Factory connections: do NOT alter Green LED (normal) Red LED (alarm/active) TB Wire Stripping Guide DATA IN (+) DATA OUT (+) DATA IN ( ) DATA OUT ( ) / in (~6 mm) From Signature controller or previous device [] To next device Strip / in (about 6 mm) from the ends of ALL wires that connect to the terminal block of the module. REAR VIEW of 70 Series CAUTION: Exposing more wire may cause a ground fault. Exposing less wire may result in a faulty connection. P/N: 8708P REV: 6.0 PG: /

11 Device addressing LEDs Mounting PRODUCT INFORMATION Description The -Stage Fire Alarm Station, 70P, is a component of the Signature Series. The 70P is a normally-open, dry contact, signal initiating device that requires one action by the user in order to initiate a pre-alarm. A keyswitch is used to activate the general alarm upon verification that evacuation is necessary. (Note: The alarm handle must be in the pulled position in order to insert the key.) The dual input module mounted to the back of the unit supervises the station. Input is used to send a pre-alarm signal to the loop controller when the switch is closed (i.e. when the handle is pulled). Input of the module is used to send an alarm signal to the loop controller when the keyswitch is activated. Two device addresses are required. The loop controller assigns two addresses to the 70P automatically. Custom addresses can be assigned to the station via laptop computer; no addressing switches are used. Diagnostic LEDs provide visible indication of the status of the station, when the unit is removed from the electrical box. Normal: Green LED flashes Alarm/active: Red LED flashes The 70P may be flush mounted in a standard in square box -/ in (8 mm) deep with -gang cover, or it may be surface mounted using a special order electrical box. (Refer to the specifications section of this sheet for ordering information.) The terminal block will accept,, 6, or 8 AWG wire (.,.,.0, or 0.7 sq mm). Sizes 6 and 8 are preferred. System controller capability The 70P requires the Signature Loop Controller. Personality Code : N/O Alarm Latching (Class B) Inputs and of the 70P are factory assigned personality code. When the keyswitch is activated, an alarm signal is sent to the loop controller and the alarm condition is latched at the fire alarm station. SPECIFICATIONS Operating voltage range: Vdc Standby current: 96 A Activated current: 680 A Operating temperature range: to 0 F (0 to 9 C) Operating humidity range: 0 to 9 % RH Construction: Cast zinc with steel backplate Operating mechanism: Single action, pull lever with keyswitch Shipping Weight:. lbs (0. kg) Compatible electrical boxes Standard in square box -/8 in ( mm) deep box with -gang cover Replacement glass rods USA, P/N 70-GLR (pkg 0 rods) CAN, P/N 76 (pkg rods) Special order surface mount boxes 79-: WHD =x-/ x -/ in (76 x x 6 mm). Red enamel. Combination / and / in knockouts top, bottom, rear. 76B-RSB: WHD = -/ x -/ x -7/6 in (89 x 8 x 6 mm). Red enamel. Combination / and / in knockouts top, bottom, rear. Wiremold C7: Buff, cream enamel finish. Combination / and in knockouts top, bottom, rear PRODUCT DIAGRAM FIRE ALARM WARNINGS This device will NOT operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. PULL IN CASE OF FIRE INSTALLATION SHEET SIGA-70P -Stage Fire Alarm Station INSTALLATION SHEET P/N: 870P REVISION LEVEL:.0 DATE: 0JUN99 FILE NAME: 870P.CDR APPROVED BY: B. Right CREATED BY: D. Chinell TM EDWARDS SYSTEMS TECHNOLOGY 6 Parkland Drive Sarasota, FL USA 6 6th Street East Owen Sound, Ontario Canada NK P8

12 INSTALLATION INSTRUCTIONS ) The 70P is shipped from the factory as an assembled unit; it contains no user-serviceable parts and should NOT be disassembled. ) Open the pull station using a flat blade screwdriver to twist the cover release screw counter-clockwise, while pulling the cover away from its backplate. ) Verify that all field wiring is free of opens, shorts, and ground faults. ) Make all wiring connections as shown in the wiring diagram. ) Write the address assigned to the module on the label provided and apply the label to the module. Peel off the removable serial number label from the module and apply it to the appropriate location in the Serial Number Logbook. 6) Using the two 6- x /8 in (6 mm) machine screws provided, mount the pull-station to the electrical box. 7) Pull the glass rod release lever and install the glass rod through the mounting bracket on the front of the pull station. Push the glass rod release lever into its closed position. Set the toggle switch to the NORMAL position, and snap the cover into its locked position. Compatible electrical box Cover release screw NORMAL LIFT Back plate Toggle switch Glass rod release lever WIRING DIAGRAM Notes [] Refer to Signature Loop Controller Installation Sheet for wiring specifications. All wiring is power-limited and supervised. Factory connections: do NOT alter Green LED (normal) Red LED (alarm/active) TB Wire Stripping Guide DATA IN (+) DATA OUT (+) DATA IN ( ) DATA OUT ( ) / in (~6 mm) From Signature controller or previous device [] To next device Strip / in (about 6 mm) from the ends of ALL wires that connect to the terminal block of the module. REAR VIEW CAUTION: Exposing more wire may cause a ground fault. Exposing less wire may result in a faulty connection. P/N: 870P REV:.0 PG: /

13 SPECIFICATIONS Temporal Continuous Operating Voltage (Note #) 0 to VDC 0 to V FWR 0 to VDC 0 to V FWR Low Vol. High Vol. Operating Current (UL 68 Individual alarm) 0mA ma 9mA 7mA 0mA ma 9mA 7mA Operating Current (UL 6 Reverse Polarity) 0mA 60mA ma 7mA 0mA 60mA ma 7mA Sound Level 0 ft (.0 M) Note # Low Volume High Volume Low Volume High Volume Anechoic - VDC 99 dba 99 dba 0 dba 99 dba 0 dba Low Vol. High Vol. Low Vol. High Vol. Anechoic - VDC 9 dba 98 dba 9 dba 98 dba Reverberant Room per UL VDC 79 dba 8 dba 79 dba 8 dba Reverberant Room per UL 0 VDC 79 dba 8 dba 79 dba 8 dba Reverberant Room per UL 68 8 dba 8 dba 8 dba 8 dba Synchronization Pulses at temporal rate within 00 ms on common circuit (Note #) Compatible Detectors Operating Temperature Operating Humidity Storage Temperature Construction & Finish Maximum Distance from Ceiling (wall mount) Compatible Electrical Boxes Shipping Weight Signature Series Detectors F to 00 F (0 C to 8 C) 0 to 9% RH - F to 0 F (-0 C to 60 C) High Impact Engineering Polymer, White in (0 mm) Low Vol. High Vol. North American " (0 mm) Square by -/8" ( mm) deep; mud box (in x in octagonal concrete ring); European 00 mm Lb. (0. Kg) NOTES:. The horn must be connected to a continuous voltage when it is set to sound a temporal horn; it may be connected to either a pulsed or continuous voltage when set to sound a steady tone.. For sleeping area installations, the HIGH VOLUME setting must be used.. The temporal pattern for the horn is : /s ON, /s OFF, /s ON, /s OFF, /s ON, -/s OFF, repeat cycle.. The base will accept # AWG (. mm ), # (. mm ), #6 (.0 mm ), and #8 (0.7 mm ) wire. Size #6 and #8 are preferred.. Break wire run at each terminal. Do not loop wires around terminals. 6. Rated F to 0 F (0 C to 9 C) when used with model SIGA-PS or SIGA-IS. 7. At power up, units may sound for 0 seconds. Do NOT connect VDC until mapping is complete. INSTALLATION INSTRUCTIONS SIGA-AB North American " (0 mm) Square -/8" ( mm) Deep Box, mud box (concrete ring); European 00 mm../6 in (7 mm) 6 /6 in (7 mm) INSTALLATION SHEET: SIGA-AB Audible Detector Base DRAWING PART NO.: 707P REVISION LEVEL:. DATE: 08//97 FILE NAME: 707.CDR APPROVED BY: RR CREATED BY: R W A UNIT OF GENERAL SIGNAL GS BUILDING SYSTEMS CORPORATION GS BUILDING SYSTEMS CORPORATION 6 Parkland Drive 6 6th Street East Sarasota, FL Owen Sound, ON, Canada

14 WIRING Base Wiring and Jumper Settings JW OUT = Low Volume IN = High Volume JW OUT = Steady Tone IN = Temporal Tone JW JW SIG - SIG + DATA (-) OUT DATA (-) IN DATA (+) IN/OUT From Power Supply To Next Sounder Base or or Previous Sounder Base EOL Relay VDC IN (+) VDC OUT (+) VDC IN (-) VDC OUT (-) DATA OUT (-) DATA IN (-) DATA IN (+) From Signature Controller or Previous Device Head Operates Its Sounder (complies with UL 68) Audible Bases 6A-00 EOL Relay DATA OUT (+) To Next Signature Device SIGA-CRR Activates ALL Sounders, Head Operates Its Sounder (complies with UL 68 & UL 6) Listed VDC Power Supply Audible Bases 6A-00 EOL Relay Listed VDC Power Supply Signature Controller Optional SIGA-CR for disabling/disconnecting sounder base Signature Controller Optional SIGA-CR for disabling/disconnecting sounder base NOTES All wiring supervised and power limited. Sounder operates when detector operates (UL 68). Sounder operates when polarity of power supply is reversed, i.e. SIGA-CRR module activated (UL 6). Optional SIGA-CR module used to silence sounders. End-Of-Line relay must monitor and report power supply trouble to control panel. 6 Class B data wiring may be "T-tapped." 7 Polarity of power supply circuit shown in supervisory state.

15 PRODUCT INFORMATION DESCRIPTION The Single Input Signal Module, Model SIGA-CC, is a component of the Signature Series System. The SIGA-CC is an analog addressable device used to connect a supervised output circuit to the riser bus. The SIGA-CC does NOT provide supervision of the riser; the fire alarm panel must provide this function. Upon command from the loop controller, the SIGA-CC connects the output circuit to the riser input which may be VDC to operate polarized audible and visual signals, V or 70V to operate audio evacuation circuits, or telephone audio. One () device address is required. The actual function performed by the SIGA-CC is determined by the personality code that is downloaded to the module by the Signature Loop Controller during system configuration. The loop controller assigns an address to the SIGA-CC automatically or a custom address can be assigned to the module via laptop computer; no addressing switches are used. Diagnostic LEDs provide visible indication of the status of the module when the cover plate is removed. Status Normal Alarm/Active LED Indicator Green LED flashes. Red LED flashes. Operating Voltage Range Standby Current Activated Current Output Ratings: V DC V Audio 70V Audio EOL Resistor Value (EOLR) Max. Circuit Resistance Max. Circuit Capacitance Operating Temperature Range Operating Humidity Range Storage Temperature Range Construction Shipping Weight Compatible Electrical Boxes SPECIFICATIONS Vdc A 00 A A 0W W 7K, UL/ULC Listed Refer to Manual 0. F to 0 F (0 to 9 C) 0 to 9% RH - to 0 F (-0 to 60 C) High Impact Polymer 7.7 oz (8 g) North American -/" (6 mm) Deep -Gang Box Standard Square Box -/" (8 mm) Deep Box European 00 mm Square Box Comments: ) Power limited when connected to a power-limited power supply. ) Power limited when connected to a power-limited audio amplifier. ) Non-power limited when connected to a non-power limited source. Power limited mark must be covered up. The SIGA-CC can be mounted in a NorthAmerican -/" (6 mm) deep -gang box, standard " square -/" (8 mm) deep box, or European 00 mm square box. The terminal blocks will accept #, 6 or 8 AWG wire (. mm,.0 mm, 0.7 mm ). Sizes #6 and #8 are preferred. SYSTEM CONTROLLER COMPATIBILITY The SIGA-CC requires the Signature Loop Controller. The loop controller downloads the personality code which determines how the module will operate. The following personality codes may be downloaded to the SIGA-CC: Personality Code : Riser Selector (Single Input) The SIGA-CC is factory assigned personality code. Personality code configures the SIGA-CC as a Signal Power (VDC) or Audio Evacuation ( or 70 V) Riser Selector. Since the SIGA-CC is NOT being used for telephone audio under this personality code, the ring-tone generator is DISABLED. The output circuit is monitored for open or shorted wiring. If a short exists, the control panel inhibits the activation of the audible/visual signal circuit, so the riser is not connected to the wiring fault. WARNINGS ) This module will NOT operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. ) This module does NOT support conventional smoke detectors. Single Input Signal Module, SIGA-CC Personality Code 6: Riser Selector (Single Input), Ring-Tone Personality code 6 configures the SIGA-CC as a Telephone Riser Selector. When a telephone handset is plugged into its jack or lifted from its hook, the SIGA-CC will generate its own ring-tone signal (a separate ring-tone riser is NOT needed). The module sends this signal to the control panel to indicate that an off-hook condition is present, and waits for the system operator to respond to the call. When the system operator responds, the ring-tone signal is DISABLED. IMPORTANT NOTE: TRANSIENT PROTECTION INSTALLATION SHEET: This module requires transient protection for installations in which electromechanical bells or horns are connected to the output circuits. A Bi-Polar Transient Protector (P/N 96P) MUST be used to protect the module's electronic circuitry from the effects of electronic transients caused by the inductive load of bells or horns. The bi-polar transient protector assembly should be connected across the terminals of the bell or horn located electrically closest to the module. The bi-polar transient protector is not polarity sensitive. Bells and horns MUST be located a minimum of 6 ft. (.8 m) from the module. INSTALLATION SHEET P/N: 870P REVISION LEVEL: 6.0 DATE: 07/06/98 A UNIT OF GENERAL SIGNAL GS BUILDING SYSTEMS CORPORATION SIGA-CC Single Input Signal Module FILE NAME: 870P.CDR APPROVED BY: LM CREATED BY: MR GS BUILDING SYSTEMS CORPORATION 6 Parkland Drive Sarasota, FL USA 6 6th Street East Owen Sound, Ontario Canada NK P8

16 ) The SIGA-CC is shipped from the factory as an assembled unit; it contains no user-serviceable parts and should NOT be disassembled. ) Refer to Technical Bulletin (P/N 70) for installation guidelines. ) Verify that all field wiring is free of opens, shorts, and ground faults. ) Make all wiring connections as shown in the wiring diagram. ) Write the address assigned to the module on the label provided and apply the label to the module. Peel off the removable serial number label from the module and apply it to the appropriate location in the Serial Number Logbook. 6) Using the two 6- x /8" (9. mm) machine screws provided, mount the module to the electrical box. 7) Using the four - x /6" (7.9 mm) self-tapping screws provided, mount the wall plate to the module. NOTE: ) Wire in accordance with NFPA70-996, National Electrical Code Article 760, Section 760-(a)(), Exceptions No. and. INSTALLATION INSTRUCTIONS Wire Stripping Guide Strip /" (6. mm) from the ends of ALL wires that connect to the terminal block of the module. CAUTION: Exposing more than /" (6. mm) of wire may cause a ground fault. Exposing less than /" (6. mm) of wire may result in a faulty connection. Single Input Signal Module, SIGA-CC (Personality Code or 6) 6) For maximum wire resistance, refer to the appropriate technical reference manual. Max. #AWG (. mm ) wire; Min. #8 (0.7 mm ) Refer to Signature Loop Controller Installation Sheet for wiring specifications. Power-limited and supervised. Supervised and power limited when connected to power limited source. If non-power limited, then all power limited wiring in box must use FPL, FPLR, or FPLP cable or equivalent per NEC. Power limited marking must be eliminated. This module will NOT support -wire smoke detectors. 7) Polarity at terminals 9 & 0 on Notification Appliance, Telephone, and Speaker Circuits shown in Supervisory condition. Connect as shown in diagram. (Polarity reverses on alarm.)

17 PRODUCT INFORMATION DESCRIPTION The Dual Input Signal Module, Model SIGA-CC, is a component of the Signature Series System. The SIGA-CC is an analog addressable device used to connect up to two supervised output circuits (riser and riser ). The SIGA-CC does NOT provide supervision of the riser; the fire alarm panel must provide this function. Upon command from the loop controller, the SIGA-CC connects the output circuit to either the riser or riser bus; which may be VDC to operate polarized audible and visual signals or V or 70V to operate audio evacuation circuits. Two () device addresses are required. The actual function performed by the SIGA-CC is determined by the personality code that is downloaded to the module by the Signature Loop Controller during system configuration. The loop controller assigns two addresses to the SIGA-CC automatically or custom addresses can be assigned to the module via laptop computer; no addressing switches are used. Diagnostic LEDs provide visible indication of the status of the module when the cover plate is removed. Status Normal Alarm/Active LED Indicator Green LED flashes. Red LED flashes. The SIGA-CC can be mounted in a North American -/" (6 mm) deep - gang box, standard " square -/" (8 mm) deep box, or European 00 mm square box. The terminal blocks will accept #, 6 or 8AWG wire (. mm,.0 mm, 0.7 mm ). Sizes #6 and #8 are preferred. SYSTEM CONTROLLER COMPATIBILITY The SIGA-CC requires the Signature Loop Controller. The loop controller downloads the personality code which determines how the module will operate. The following personality code may be downloaded to the SIGA- CC: Personality Code 7: Riser Selector (Dual Input) The SIGA-CC is factory assigned personality code 7. Personality code 7 configures the SIGA-CC as a one of two output Signal Power (V DC) or. Audio Evacuation ( or 70V) Riser Selector. Each output circuit is monitored for open or shorted wiring. If a short exists, the control panel inhibits the activation of the audible/visual signal circuit, so the riser is not connected to the wiring fault. Operating Voltage Range Standby Current Activated Current Output Ratings: V DC V Audio 70V Audio EOL Resistor Value (EOLR) Max. Circuit Resistance Max. Circuit Capacitance Operating Temperature Range Operating Humidity Range Storage Temperature Range Construction Shipping Weight Compatible Electrical Boxes SPECIFICATIONS Vdc A 00 A A 0W W 7K, UL/ULC Listed Refer to Manual 0. F to 0 F (0 to 9 C) 0 to 9% RH - to 0 F (-0 to 60 C) High Impact Polymer 7.7 oz (8 g) North American -/" (6 mm) Deep -Gang Box Standard " Square Box -/" (8 mm) Deep Box European 00 mm Square Box WARNINGS ) This module will NOT operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. ) This module does NOT support conventional smoke detectors. Dual Input Signal Module, SIGA-CC IMPORTANT NOTE: TRANSIENT PROTECTION This module requires transient protection for installations in which electromechnanical bells or horns are connected to the output circuits. A Bi-Polar Transient Protector (P/N 96P) MUST be used to protect the module's electronic circuitry from the effects of electronic transients caused by the inductive load of bells or horns. The bi-polar transient protector assembly should be connected across the terminals of the bell or horn located electrically closest to the module. The bi-polar transient protector is not polarity sensitive. Bells and horns MUST be located a minimum distance of 6 ft. (.8 m) from the module. INSTALLATION SHEET: INSTALLATION SHEET P/N: 8700P REVISION LEVEL: 6.0 DATE: 07/06/98 A UNIT OF GENERAL SIGNAL GS BUILDING SYSTEMS CORPORATION SIGA-CC Dual Input Signal Module FILE NAME: 8700P.CDR APPROVED BY: LM CREATED BY: MR GS BUILDING SYSTEMS CORPORATION 6 Parkland Drive 6 6th Street East Sarasota, FL Owen Sound, ON, Canada

18 INSTALLATION INSTRUCTIONS ) The SIGA-CC is shipped from the factory as an assembled unit; it contains no user-serviceable parts and should NOT be disassembled. ) Refer to Technical Bulletin (P/N 70) for installation guidelines. ) Verify that all field wiring is free of opens, shorts, and ground faults. ) Make all wiring connections as shown in the wiring diagram. ) Write the address assigned to the module on the label provided and apply the label to the module. Peel off the removable serial number label from the module and apply it to the appropriate location in the Serial Number Logbook. 6) Using the two 6- x /8" (9. mm) machine screws provided, mount the module to the electrical box. 7) Using the four - x /6" (7.9 mm) self-tapping screws provided, mount the wall plate to the module. NOTE: ) Wire in accordance with NFPA70-996, National Electrical Code Article 760, Section 760-(a)(), Exceptions No. and. Wire Stripping Guide Strip /" (6. mm) from the ends of ALL wires that connect to the terminal block of the module. CAUTION: Exposing more than /" (6. mm) of wire may cause a ground fault. Exposing less than /" (6. mm) of wire may result in a faulty connection. Dual Input Signal Module, SIGA-CC (Personality Code 7) For maximum wire resistance, refer to the appropriate technical reference manual. Max. # AWG (. mm ) wire; Min. #8 (0.7 mm ). Refer to Signature Loop Controller Installation Sheet for wiring specifications. Power-limited and supervised. Supervised and power limited when connected to power limited source. If non-power limited, then all power limited wiring in box must use FPL, FPLR, or FPLP cable or equivalent per NEC. Power limited marking must be eliminated. 6 This module will not support -wire smoke detectors. 7 Polarity at terminals 9 and 0 on Notification Appliance, Telephone, and Speaker Circuits shown in Supervisory condition. Connect as shown in diagram (polarity reverses on alarm).

19 PRODUCT INFORMATION SPECIFICATIONS DESCRIPTION The Control Relay Module, Model SIGA-CR, is a component of the Signature Series System. The SIGA-CR is an addressable device used to provide one Form "C" dry relay contact to control external appliances (door closers, fans, dampers, etc.) or equipment shutdown. The system firmware ensures that the relay is in the proper ON/OFF state. Upon command from the loop controller, the SIGA-CR relay energizes. TB-6 and TB-7 provide a normally-closed relay connection; TB-7 and TB-8 provide a normallyopen relay connection. One () device address is required. The loop controller assigns an address to the SIGA-CR automatically or a custom address can be assigned to the module via laptop computer; no addressing switches are used. Diagnostic LEDs provide visible indication of the status of the module, when the cover plate is removed. Status Normal Alarm/Active LED Indicator Green LED flashes. Red LED flashes. Operating Voltage Range Standby Current Activated Current Contact Ratings (Pilot Duty): V DC 0 AC Relay Type Operating Temperature Range Operating Humidity Range Storage Temperature Range Construction Vdc 00 A 00 A A 0.A Form "C" to 0 F (0 to 9 C) 0 to 9% RH - to 0 F (-0 to 60 C) High Impact Engineering Polymer. oz ( g) Shipping Weight Compatible Electrical Boxes North American -/" (6 mm) Deep -Gang Box Standard " Square Box -/" (8 mm) Deep Box with -Gang Cover The SIGA-CR can be mounted in a North American -/" (6 mm) deep -gang box, or standard " square -/" (8 mm) deep box with -gang cover. The terminal blocks will accept #, 6 or 8 AWG wire (. mm,.0 mm, 0.7 mm ). Sizes #6 and #8 are preferred. SYSTEM CONTROLLER COMPATIBILITY The SIGA-CR requires the Signature Loop Controller. Personality Code 8: Dry Contact Output The SIGA-CR is factory assigned personality code 8 which configures the SIGA-CR as an output dry relay contact. WARNINGS ) This module will NOT operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. ) Dangerouos voltages may be present at terminals even when power is shut off!! Control Relay Module, SIGA-CR INSTALLATION SHEET: SIGA-CR Control Relay Module INSTALLATION SHEET P/N: 870P REVISION LEVEL: 6.0 DATE: 07/06/98 FILE NAME: 870P.CDR APPROVED BY: LM CREATED BY: MR A UNIT OF GENERAL SIGNAL GS BUILDING SYSTEMS CORPORATION GS BUILDING SYSTEMS CORPORATION 6 Parkland Drive 6 6th Street East Sarasota, FL Owen Sound, ON, Canada

20 ) The SIGA-CR is shipped from the factory as an assembled unit; it contains no user-serviceable parts and should NOT be disassembled. ) Refer to Technical Bulletin (P/N 70) for installation guidelines. ) Verify that all field wiring is free of opens, shorts, and ground faults. ) Make all wiring connections as shown in the wiring diagram. ) Write the address assigned to the module on the label provided and apply the label to the module. Peel off the removable serial number label from the module and apply it to the appropriate location in the Serial Number Logbook. 6) Using the two 6- x /8" (9. mm) machine screws provided, mount the module to the electrical box. 7) Using the four - x /6" (7.9 mm) self-tapping screws provided, mount the wall plate to the module. NOTE: ) If a " ( mm) -gang box is used, conduit can enter the electrical box through ONLY ONE knock out hole. ) If a -/" (6 mm) -gang box is used, conduit can enter the electrical box through ONE or BOTH knock-out holes. ) Wire in accordance with NFPA70-996, National Electrical Code Article 760, Section 760-(a)(), Exceptions No. and. INSTALLATION INSTRUCTIONS Wire Stripping Guide Strip /" (6. mm) from the ends of ALL wires that connect to the terminal block of the module. CAUTION: Exposing more than /" (6. mm) of wire may cause a ground fault. Exposing less than /" (6. mm) of wire may result in a faulty connection. Control Relay Module, SIGA-CR (Personality Code 8) Refer to Signature Loop Controller Installation Sheet for wiring specifications. SIGA-CR must be installed within the same room as the device it is controlling. ) Maximum # AWG (.mm ) wire; Minimum #8AWG (0.7mm ). Power limited and supervised. Supervised and power limited when connected to power limited source. If non-power limited, then all power limited wiring in box must use FPL, FPLR, or FPLP cable or equivalent per NEC. Power limited marking must eliminated.

21 PRODUCT INFORMATION DESCRIPTION The Polarity Reversal Relay Module, Model SIGA-CRR, is a component of the Signature Series System. The SIGA-CRR is an addressable device used to power and activate the audible sounder in SIGA-AB Audible Bases. The module can support a amp load of Audible Bases. The system firmware ensures that the relay is in the proper state when powered up. Upon command from the loop controller, the SIGA-CRR relay energizes, reversing the polarity of its VDC output. One () device address is required for the Polarity Reversal Relay Module. The loop controller assigns an address to the SIGA-CRR automatically or a custom address can be assigned to the module via laptop computer; no addressing switches are used. Diagnostic LEDs provide visible indication of the status of the module. Status Normal Alarm/Active LED Indicator Green LED flashes. Red LED flashes. Operating Voltage Range Standby Current Activated Current Contact Ratings (Pilot Duty): V DC Operating Temperature Range Operating Humidity Range Storage Temperature Range Construction SPECIFICATIONS Vdc 00 A 00 A A F to 0 F (0 C to 9 C) 0 to 9% RH - F to 0 F (-0 C to 60 C) High Impact Engineering Polymer. oz ( g) Shipping Weight Compatible Electrical Boxes North American -/" (6 mm) Deep -Gang Box Standard " Square Box -/" (8 mm) Deep w/-gang Cover The SIGA-CRR can be mounted in a North American -/" (6 mm) deep -gang box, or standard " square -/" (8 mm) deep box with -gang cover. The module can also be mounted in the fire alarm enclosure using the SIGA-MP Mounting Plate. The terminal blocks will accept #, 6, or 8 AWG wire (. mm,.0 mm, 0.7 mm ). SYSTEM CONTROLLER COMPATIBILITY The SIGA-CRR requires a Signature Loop Controller to operate. Personality Code 8: Dry Contact Output The SIGA-CRR is factory assigned personality code 8 which configures the SIGA-CRR as a constant power polarity reversing device. WARNINGS ) This module will NOT operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. SIGA-CRR INSTALLATION SHEET: SIGA-CRR Polarity Reversal Relay Module INSTALLATION SHEET P/N: 876P REVISION LEVEL:.0 DATE: 09//97 FILE NAME: 876P.CDR APPROVED BY: RR CREATED BY: R W A UNIT OF GENERAL SIGNAL GS BUILDING SYSTEMS CORPORATION GS BUILDING SYSTEMS CORPORATION 6 Parkland Drive 6 6th Street East Sarasota, FL Owen Sound, ON, Canada

22 INSTALLATION INSTRUCTIONS SIGA-CRR, Personality Code 8 ) The SIGA-CRR is shipped from the factory as an assembled unit; it contains no user-serviceable parts and should NOT be disassembled. ) Verify that all field wiring is free of opens, shorts, and ground faults. ) Make all wiring connections as shown in the wiring diagram. ) Write the address assigned to the module on the label provided and apply the label to the module. Peel off the removable serial number label from the module and apply it to the appropriate location in the Serial Number Logbook. ) Using the two 6- x /" ( mm) machine screws provided, mount the module to the electrical box. 6) Using the - x /6" (8 mm) self-tapping screw provided, mount the wall plate to the module. 7) The module can be mounted in the fire alarm enclosure using the SIGA-MP Mounting Plate. NOTES: ) If a " ( mm) -gang box is used, conduit can enter the electrical box through ONLY ONE knock-out. ) If a -/" (6 mm) -gang box is used, conduit can enter the electrical box throuogh ONE or BOTH knock-outs. ) Wire in accordance with NFPA70-996, National Electrical code Article 760, Section 760-(a)(), Exception No. and. Wire Stripping Guide Listed VDC Power Supply Schematic Head Operates its Sounder Audible Bases 6A-00 EOL Relay Strip /" (6. mm) from the ends of ALL wires that connect to the terminal block of the module. CAUTION: Exposing more than /" (6. mm) of wire may cause a ground fault. Exposing less than /" (6. mm) of wire may result in a faulty connection. SIGA-MP Signature Controller Optional SIGA-CR for disabling/disconnecting sounder base SIGA-CRR Activates ALL Sounders, Head Operates its Sounder Listed VDC Power Supply Audible Bases 6A-00 EOL Relay Compatible Electrical Box Wall Plate, White (-Gang) Self Adhesive French Label (Optional) Signature Controller Optional SIGA-CR for disabling/disconnecting sounder base Notes All wiring is power-limited and supervised.

23 PRODUCT INFORMATION DESCRIPTION The Single Input Module, Model SIGA-CT, is a component of the Signature Series System. The SIGA-CT is an analog addressable device used to connect a Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuit (IDC) to a Signature Loop Controller. One () device address is required. The SIGA-CT may be used for Alarm, Supervisory, or Monitor type applications as determined by the personality code that is downloaded to the module by the loop controller during system configuration. The loop controller assigns an address to the SIGA-CT automatically, or a custom address can be assigned to the module via laptop computer; no addressing switches are used. Diagnostic LEDs provide visible indication of the status of the module, when the cover plate is removed. Status Normal Alarm/Active LED Indicator Green LED flashes. Red LED flashes. The SIGA-CT can be mounted in a North American -/" (6 mm) deep - gang box, or standard " square box -/" (8 mm) deep with -gang cover. The terminal blocks will accept #, 6, or 8 AWG wire (. mm,.0 mm, 0.7 mm ). Sizes #6 and #8 are preferred. SYSTEM CONTROLLER COMPATIBILITY The SIGA-CT requires the Signature Loop Controller. The loop controller downloads the personality code which determines how the module will operate. The following personality codes may be downloaded to the SIGA- CT: Personality Code : N/O Alarm Latching (Class B) The SIGA-CT is factory assigned personality code. Personality code configures the SIGA-CT for Class B normally-open dry contact initiating devices (e.g., pull-stations, heat detectors, etc.). When the N/O input contact of an initiating device is closed, an alarm signal is sent to the loop controller and the alarm condition is latched at the module. Personality Code : N/O Alarm Delayed Latching (Class B) Personality code operates the same as personality code except that contact closure must be maintained for approximately 6 seconds before an Alarm status is generated. Personality code is only for use with nonretarded waterflow alarm switches. Operating Voltage Range Standby Current Activated Current Operating Temperature Range Operating Humidity Range Storage Temperature Range Construction SPECIFICATIONS. to 9.9 Vdc 0 A 00 A to 0 F (0 to 9 C) 0 to 9% RH - to 0 F (-0 to 60 C) High Impact Engineering Polymer. oz ( g) Shipping Weight Compatible Electrical Boxes North American -/" (6 mm) Deep -Gang Box Standard " Square Box -/" (8 mm) Deep Box w/-gang Cover Initiating Device Circuit (IDC): EOL Resistor Value (EOLR) 7K, UL Listed Max. Circuit Resistance 0 ( per wire) Max. Circuit Capacitiance 0. F Wire Size Max. Distance to EOLR #8 AWG (0.7 mm ),90' (,98m) #6 AWG (.0 mm ) 6,' (,897m) # AWG (. mm ) 9,900' (,08m) WARNINGS ) This module will NOT operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. ) This module does NOT support conventional smoke detectors. Single Input Module, SIGA-CT Personality Code : N/O Active - Non-latching (Class B) A contact closure causes an active instead of an alarm status and does NOT latch at the module. Personality code is typically used for monitoring fans, dampers, doors, etc. Personality Code : N/O Active Latching (Class B) A contact closure causes an active instead of an alarm status, which is latched at the module. Personality code is typically used for monitoring supervisory and tamper switches. IMPORTANT NOTE: TRANSIENT PROTECTION INSTALLATION SHEET: SIGA-CT Single Input Module INSTALLATION SHEET P/N: 870P REVISION LEVEL: 6.0 DATE: 0/0/98 FILE NAME: 870P.CDR APPROVED BY: RR CREATED BY: MR A UNIT OF GENERAL SIGNAL GS BUILDING SYSTEMS CORPORATION GS BUILDING SYSTEMS CORPORATION 6 Parkland Drive 6 6th Street East Sarasota, FL Owen Sound, ON, Canada

24 INSTALLATION INSTRUCTIONS ) The SIGA-CT is shipped from the factory as an assembled unit; it contains no user-serviceable parts and should NOT be disassembled. ) Refer to Technical Bulletin (P/N 70) for installation guidelines. ) Verify that all field wiring is free of opens, shorts, and ground faults. ) Make all wiring connections as shown in the wiring diagram. ) Write the address assigned to the module on the label provided and apply the label to the module. Peel off the removable serial number label from the module and apply it to the appropriate location in the Serial Number Logbook. 6) Using the two 6- x /" ( mm) machine screws provided, mount the module to the electrical box. 7) Using the four - x /6" (8 mm) self-tapping screws provided, mount the wall plate to the module. NOTES: ) If a " ( mm) -gang box is used, conduit can enter the electrical box through ONLY ONE knock-out hole. ) If a -/" (6 mm) -gang box is used, conduit can enter the electrical box through ONE or BOTH knock-out holes. Wire Stripping Guide Strip /" (6. mm) from the ends of ALL wires that connect to the terminal block of the module. CAUTION: Exposing more than /" (6. mm) of wire may cause a ground fault. Exposing less than /" (6. mm) of wire may result in a faulty connection. Single Input Module (Personality Codes,,, and ) NOTES Maximum resistance per wire. Max. #AWG (. mm ) wire; Min. #8 (0.7 mm ). Refer to Signature Loop Controller Installation Sheet for wiring specifications. Maximum 0 0 A. ) All wiring is power-limited and supervised. 6) This module will NOT support -wire smoke detectors.

25 PRODUCT INFORMATION DESCRIPTION The Dual Input Module, model SIGA-CT, is a component of the Signature Series System. The SIGA-CT is an analog addressable device used to connect up to two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (IDCs) to a Signature Loop Controller. Two () device addresses are required. The SIGA-CT may be used for Alarm, Supervisory, or Monitor type applications as determined by the personality code that is downloaded to the module by the loop controller during system configuration. The loop controller assigns an address to the SIGA-CT automatically, or custom addresses can be assigned to the module via laptop computer; no addressing switches are used. Diagnostic LEDs provide visible indication of the status of the module, when the cover plate is removed. Status Normal Alarm/Active LED Indicator Green LED flashes. Red LED flashes. The SIGA-CT can be mounted in a North American -/" (6 mm) deep - gang box, or standard " square box -/" (8 mm) deep with -gang cover. The terminal blocks will accept #, 6, or 8 AWG wire (. mm,.0 mm, 0.7 mm ). Sizes #6 and #8 are preferred. SYSTEM CONTROLLER COMPATIBILITY The SIGA-CT requires the Signature Loop Controller. The loop controller downloads the personality code which determines how the module will operate. The following personality codes may be downloaded to the SIGA- CT: Personality Code : N/O Alarm Latching (Class B) The SIGA-CT is factory assigned personality code to input channels and. Personality code configures the SIGA-CT for Class B normallyopen dry contact initiating devices (e.g., pull-stations, heat detectors, etc.). When the N/O input contact of an initiating device is closed, an alarm signal is sent to the loop controller and the alarm condition is latched at the module. Personality Code : N/O Alarm Delayed Latching (Class B) Personality code operates the same as personality code except that contact closure must be maintained for approximately 6 seconds before an Alarm status is generated. Personality code is only for use with nonretarded waterflow alarm switches. Operating Voltage Range Standby Current Activated Current Operating Temperature Range Operating Humidity Range Storage Temperature Range Construction Shipping Weight Compatible Electrical Boxes North American -/" (6 mm) Deep -Gang Box Standard " Square Box -/" (8 mm) Deep Box w/-gang Cover Initiating Device Circuit (IDC): EOL Resistor Value (EOLR) 7K, UL Listed Max. Circuit Resistance 0 ( per wire) (per channel) Max. Circuit Capacitiance (per channel) SPECIFICATIONS Vdc 96 A 680 A to 0 F (0 to 9 C) 0 to 9% RH - to 0 F (-0 to 60 C) High Impact Engineering Polymer. oz ( g) 0. F Wire Size Max. Distance to EOLR #8 AWG (0.7 mm ),90' (,98m) #6 AWG (.0 mm ) 6,' (,897m) # AWG (. mm ) 9,900' (,08m) WARNINGS ) This module will NOT operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. ) This module does NOT support conventional smoke detectors. Dual Input Module, SIGA-CT Personality Code : N/O Active - Non-Latching (Class B) A contact closure causes an active instead of an alarm status and does NOT latch at the module. Personality code is typically used for monitoring fans, dampers, doors, etc. Personality Code : N/O Active Latching (Class B) A contact closure causes an active instead of an alarm status, which is latched at the module. Personality code is typically used for monitoring supervisory and tamper switches. INSTALLATION SHEET: SIGA-CT Dual Input Module INSTALLATION SHEET P/N: 8707P REVISION LEVEL: 6.0 DATE: 0/0/98 FILE NAME: 8707P.CDR APPROVED BY: RR CREATED BY: MR A UNIT OF GENERAL SIGNAL GS BUILDING SYSTEMS CORPORATION GS BUILDING SYSTEMS CORPORATION 6 Parkland Drive 6 6th Street East Sarasota, FL Owen Sound, ON, Canada

26 INSTALLATION INSTRUCTIONS ) The SIGA-CT is shipped from the factory as an assembled unit; it contains no user-serviceable parts and should NOT be disassembled. ) Refer to Technical Bulletin (P/N 70) for installation guidelines. ) Verify that all field wiring is free of opens, shorts, and ground faults. ) Make all wiring connections as shown in the wiring diagram. ) Write the address assigned to the module on the label provided and apply the label to the module. Peel off the removable serial number label from the module and apply it to the appropriate location in the Serial Number Logbook. 6) Using the two 6- x /" ( mm) machine screws provided, mount the module to the electrical box. 7) Using the four - x /6" (8 mm) self-tapping screws provided, mount the wall plate to the module. NOTES: ) If a " ( mm) -gang box is used, conduit can enter the electrical box through ONLY ONE knock-out hole. ) If a -/" (6 mm) -gang box is used, conduit can enter the electrical box through ONE or BOTH knock-out holes. ) Wire in accordance with NFPA70-996, National Electrical Code Article 760, Section 760-(a)(), Exception No. and. Wire Stripping Guide Strip /" (6. mm) from the ends of ALL wires that connect to the terminal block of the module. CAUTION: Exposing more than /" (6. mm) of wire may cause a ground fault. Exposing less than /" (6. mm) of wire may result in a faulty connection. Single Input Module (Personality Codes,,, and ) Maximum resistance per wire. Max. #AWG (. mm ) wire; Min. #8 (0.7 mm ). Refer to Signature Loop Controller Installation Sheet for wiring specifications. Maximum 0 0 A. ) All wiring is power-limited and supervised. 6) This module will NOT support -wire smoke detectors.

27 PRODUCT INFORMATION The model SIGA-DG Detector Guard is designed to prevent mechanical damage to Signature Series smoke detectors. Use of the guard does not affect detector performance, and requires no detector sensitivity increase. The guard is finished in white enamel, and secured with tamper-proof fasteners. Construction Finished Dimensions Compatible Devices Detectors SPECIFICATIONS 6 gauge steel 6." diameter x." height (6.cm x 8.6cm) SIGA-IPHS XLS-IPHS SIGA-PS XLS-PS GSA-PS INSTALLATION. Fasten the detector base (B) to the SIGA-DG mounting flange (A) using the two #8- machine screws provided.. Install the mounting flange and detector base (A & B) over the electrical box, using appropriate fasteners Mounting holes provide clearance for a #0 screw. Route the base wiring through the hole in the detector base.. Wire the base in accordance with the instructions provided with the base, then install the detector (C).. Secure the SIGA-DG guard cage (D) to the mounting flange using the four tamper-proof screws provided, and tighten securely. Bases Spacing Finish SIGA-IB SIGA-RB SIGA-SB Listed detector spacing is not affected by the guard White enamel GSA-IB GSA-RB GSA-SB INSTALLATION SHEET: SIGA-DG Detector Guard INSTALLATION SHEET P/N: 877P REVISION LEVEL:.0 DATE: 0//97 FILE NAME: 877(R.0).CDR APPROVED BY: RR CREATED BY: R W GS BUILDING SYSTEMS, CORP. SARASOTA, FL Fax: CHESHIRE, CT Fax: OWEN SOUND, CANADA Fax: INTERNATIONAL: CANADA Fax:

28

29 PRODUCT INFORMATION The model SIGA-DG Detector Guard is designed to prevent mechanical damage to surface mounted Signature Series smoke detectors when used with the SIGA-DGS surface adapter. Use of the guard does not affect detector performance, and requires no detector sensitivity increase. Construction Dimensions Surface Adapter SPECIFICATIONS 6 gauge steel 8.87" diameter x." height (.cm x.7cm) The guard is finished in white enamel, and secured with tamper-proof fasteners. INSTALLATION. Install the SIGA-DGS surface adapter (A) over the electrical box/conduit using appropriate fasteners. Mounting holes provide clearance for a #0 screw.. Fasten the detector base (C) to the SIGA-DG mounting flange (B) using the two #8- machine screws provided.. Install the mounting flange and detector base (B & C) on surface adapter, using four #8 bolts provided. Route the base wiring through the hole in the base.. Wire the base in accordance with the instructions provided with the base, then install the detector (D).. Secure the guard cage (E) to the mounting flange using the four tamper-proof bolts provided, and tighten securely. Adapter & Guard Compatible Devices Detectors Bases Spacing Finish 8.87" diameter x." height (.cm x.97cm) SIGA-IPHS XLS-IPHS SIGA-PS XLS-PS GSA-PS SIGA-IB SIGA-RB SIGA-SB Listed detector spacing is not affected by the guard White enamel GSA-IB GSA-RB GSA-SB INSTALLATION SHEET: SIGA-DGS Surface Adapter for use with the SIGA-DG Detector Guard INSTALLATION SHEET P/N: 878P REVISION LEVEL:.0 DATE: 0//97 FILE NAME: 878(R.0).CDR APPROVED BY: RR CREATED BY: R W GS BUILDING SYSTEMS, CORP. SARASOTA, FL Fax: CHESHIRE, CT Fax: OWEN SOUND, CANADA Fax: INTERNATIONAL: CANADA Fax:

Signature Series Auto-Sync Output Module (CC1S)

Signature Series Auto-Sync Output Module (CC1S) Signature Series Auto-Sync Output Module (CC1S) Product description Mounting The Signature Series can be mounted in a North American 2-1/2 in (64 mm) deep 2-gang box or a standard 4 in square box 1-1/2

More information

SIGA-CC1 Single Input Signal Module Installation Sheet

SIGA-CC1 Single Input Signal Module Installation Sheet SIGA-CC1 Single Input Signal Module Installation Sheet Personality codes Use the personality codes described below to configure the SIGA-CC1 module. See Table 1 for listing information Table 1: Personality

More information

Control Relay Modules

Control Relay Modules TM INTERNATIONAL ANALOG ADDRESSABLE INPUT/OUTPUT DEVICES Control Relay Modules Model SIGA-CR, SIGA-MCR, SIGA-CRR, Features! Provides one no/nc contact (SIGA-CR/MCR) Form C dry relay contact can be used

More information

Booster Power Supply Manual

Booster Power Supply Manual Supply Manual DEVELOPED BY COPYRIGHT NOTICE General Signal Building Systems Corporation 6411 Parkland Drive Sarasota, FL 34243 (941) 739-4300 Copyright 1999 General Signal Building Systems Corporation

More information

Print Specification. Publication. Instructions. Specific requirements. General requirements

Print Specification. Publication. Instructions. Specific requirements. General requirements Print Specification Publication GSA-CC1 Single Input Signal Module Installation Sheet P/N P-047550-1802-EN REV 04 ISS 23JUN15 Instructions This page is the print specification for the publication. It is

More information

Addressable Detectors & Bases

Addressable Detectors & Bases Edwards Signaling Catalog u Intelligent Initiating Addressable Detectors & Bases Detectors: E-PD, E-PHD, E-HD Bases: B4U, RB4U, IB4U, SB4U Overview Edwards intelligent addressable detectors are meticulously

More information

FIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS

FIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS VALOUR COMMUNITY CENTRE FIRE ALARM SYSTEM Section 28 00 00 GYMNASIUM ADDITION & RENOVATION Page 1 of 3 28 00 00 FIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS 1.2 SCOPE 1. The specification covering the General

More information

WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE EST LIFE SAFETY PRODUCTS DETECTORS AND MODULES ... EDWARDS SYSTEMS TECHNOLOGY

WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE EST LIFE SAFETY PRODUCTS DETECTORS AND MODULES ... EDWARDS SYSTEMS TECHNOLOGY S I G N A T U R E S E R I E S WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE.... EST LIFE SAFETY PRODUCTS...... DETECTORS AND MODULES... EDWARDS SYSTEMS TECHNOLOGY TM SIGNATURE SERIES LIFE SAFETY DEVICES.

More information

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels R 12 Clintonville Road, Northford, CT 06472 Phone: (203) 484-7161 FAX: (203) 484-7118 Instruction Manual for the MS-4012/4024 and CMS-4012/4024 Fire Alarm Control Panels Document 15586 5/11/93 Revision:

More information

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906 s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones

More information

io64 Intelligent Life Safety System

io64 Intelligent Life Safety System EST Catalog u Small Building Fire Alarm Solutions io64 Intelligent Life Safety System Overview The Edwards EST io64 intelligent life safety system offers the power of high-end intelligent processing in

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

SC-6 Six Supervised Control Module

SC-6 Six Supervised Control Module INSTALLATION AND MAINTENANCE INSTRUCTIONS SC-6 Six Supervised Control Module SPECIFICATIONS Normal Operating Voltage: Stand-By Current: Alarm Current: Temperature Range: Humidity: Dimensions: Accessories:

More information

ANNUNCIATOR FIXED MODULE

ANNUNCIATOR FIXED MODULE 12 Clintonville Road Northford, CT 06472 Phone: 203-484-7161 Fax: 203-484-7118 THE ANNUNCIATOR FIXED MODULE Installation Manual for the AFM-16ATF and AFM-32AF Annunciator Modules Document # 15970 3/27/95

More information

Addressable NAC Output Module D327A

Addressable NAC Output Module D327A Installation Instructions Notice Addressable NAC Output Module D327A These instructions cover the installation of the D327A Addressable NAC Output Module in an analog system controlled by a Bosch D8024,

More information

V-Series Life Safety Systems

V-Series Life Safety Systems es ol Submittal Guide Life Safety Systems Analog addressable fire alarm arm solutions for small buildings iati ting es ion on S e e e e V I G I L A N T B R A N D F I R E & L I F E S A F E T Y F R O M E

More information

SECTION ADDRESSABLE FIRE ALARM SYSTEM

SECTION ADDRESSABLE FIRE ALARM SYSTEM SECTION 16723 ADDRESSABLE FIRE ALARM SYSTEM 1 PART 1 GENERAL 1.1 DESCRIPTION A. This section outlines the requirements for the installation, programming and configuration of Addressable Fire Alarm System

More information

MR-2602 Two Zone Fire Alarm Control Panel

MR-2602 Two Zone Fire Alarm Control Panel MR-2602 Two Zone Fire Alarm Control Panel Installation Manual Secutron LT-2015 Rev.3 July 2010 Table of Contents 1 Introduction 1.1 The MR-2602 Fire Alarm Control Unit... 11 1.1.1 General features...

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

CZ-6A Six Zone Interface Module

CZ-6A Six Zone Interface Module INSTALLATION AND MAINTENANCE INSTRUCTIONS CZ-6A Six Zone Interface Module 658 Kitimat Rd. Unit #6 Mississauga, Ontario L5N T5-800-SENSOR, FAX: 905-8-077 www.systemsensor.ca SPECIFICATIONS Normal Operating

More information

WINDOW & HVAC REPLACEMENT PEMBERTON TOWNSHIP BOE REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5450E

WINDOW & HVAC REPLACEMENT PEMBERTON TOWNSHIP BOE REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5450E SECTION 283111 DIGITAL ADDRESSABLE FIRE ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary General Conditions of the

More information

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum. September 29, 1997 Firecycle III 433 a 1. PRODUCT NAME VIKING Model E-1 Manufactured 1997 Present 2. MANUFACTURED FOR THE VIKING CORPORATION 210 N Industrial Park Road Hastings, Michigan 49058, U.S.A.

More information

LifeAlarm Fire Alarm Controls

LifeAlarm Fire Alarm Controls UL, ULC Approved* LifeAlarm Fire Alarm Controls 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs Features Provides additional notification appliance circuit (NAC) capacity

More information

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet Table 1: Models Description Low frequency (520 Hz) horn, white housing, no FIRE marking, standard output clear strobe light Low frequency (520

More information

PSN-1000 & PSN 1000(E) Installation Manual

PSN-1000 & PSN 1000(E) Installation Manual PSN-1000 & PSN 1000(E) Installation Manual Potter Electric Signal Company, LLC St. Louis, MO Customer Service: (866) 240-1870 Technical Support: (866) 956-1211 Fax: (314) 595-6999 www.pottersignal.com

More information

good things in small packages

good things in small packages FireShield Control Panels good things in small packages life safety for small buildings and shops A perfect arrangement FireShield offers the very best conventional fire alarm technology available, with

More information

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description. Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description The TYCO RAPID RESPONSE Model RCP-1 Residential

More information

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel ACC-25/50ZST Zoned System Voice with Telephone Evacuation Control Panel General The AUDIO COMMAND CENTER 25/50 Zone System with FireFighters Telephone (ACC-25/50ZST) is a state-of-the-art Emergency Voice

More information

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances UL, ULC Approved* TrueAlert Addressable Notification Appliances Audible Notification Appliances; Multi-Tone Horns with 520 Hz Output Features Individually addressed and controlled TrueAlert ES multi-tone

More information

Addressable Fire Alarm Control Panel

Addressable Fire Alarm Control Panel PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT

More information

Release Control Fire Alarm Systems

Release Control Fire Alarm Systems SYSTEM ABORT PUSH AND HOLD COIL SUPERVISION MODULE (2 AMP) 2081-9046 RED INSTALLATION INSTRUCTIONS 574-437 REV YEL NAC+ MAINTAIN 1/4" SEPARATION BETWEEN POWER LIMITED (RED/) AND NONPOWER S LIMITED (YEL/)

More information

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions TrueAlert NonAddressable, MultiCandela Notification Appliances Installation Instructions PRODUCT IDENTIFICATION REFERENCE (See Page 4 for Detailed Product Specifications) Type Mount Model Color Operation

More information

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) SECTIONS General Description.... 1 Warnings.... 2 Technical

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D2 MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D2 GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

Multiple Input and Output Modules

Multiple Input and Output Modules Kingfisher Company, inc. Multiple Input and Output Modules Features: Removable 12 to 18 AWG plug-in terminal blocks Individual LED indicators Unused addresses may be disabled Rotary address switches Class

More information

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION: RELEASE DEVICES MADE IN THE U.S.A. RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: The "WPS" World Power Series, Time Delay Release

More information

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS MODEL XR5FC/XR5SL COMMAND PROCESSOR INSTALLATION GUIDE FCC NOTICE This equipment generates and uses radio frequency energy and, if not installed

More information

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL MADE IN THE U.S.A. U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION SERIAL NUMBER The Cookson Company FIREFLY II PLUS Time Delay Release

More information

Model 17A00 Expansion Enclosure

Model 17A00 Expansion Enclosure HOME AUTOMATION, INC. Model 17A00 Expansion Enclosure Installation Manual Document Number 17I00-1 Rev A March, 2002 Home Automation, Inc. Model 17A00 Expansion Enclosure Installation Manual Document Number

More information

MODEL B2 INSTALLATION MANUAL

MODEL B2 INSTALLATION MANUAL RELEASE DEVICES GENERAL DESCRIPTION MODEL B2 INSTALLATION MANUAL S/N: The B2 Series Time Delay Release Devices are UL Listed, Canadian Listed, and CSFM Listed for use on rolling doors, single-slide and

More information

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

THE SS90 SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL S S S S S S S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED U 99Y9 RESET L RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

Remote Booster Power Supply Technical Reference Manual

Remote Booster Power Supply Technical Reference Manual E Security Fire & Life Safety Remote Booster Power Supply Technical Reference Manual P/N 3100485 RE 3.0 ISS 06JUL07 Copyright Copyright 2007 E Security, Inc. ll rights reserved. This document may not be

More information

EST3 Installation and Service Manual

EST3 Installation and Service Manual EST3 Installation and Service Manual P/N 270380 Rev 3.0 21OCT99 DEVELOPED BY COPYRIGHT NOTICE TRADEMARKS CREDITS Edwards Systems Technology 6411 Parkland Drive Sarasota, FL 34243 (941) 739 4300 Copyright

More information

LifeAlarm Fire Alarm Control Panels

LifeAlarm Fire Alarm Control Panels LifeAlarm Fire Alarm Control Panels UL, ULC Approved* Features Control panel operator convenience features: Wide viewing angle 2 x 20 (40 character) alphanumeric LCD and dedicated LEDs provide convenient

More information

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays AEGIS Conventional Fire Alarm-Suppression Control Unit FEATURES Agency Approvals FM Approved FM Approved to ANSI/UL 864, 9th edition FM Approved to ULC-S527-99 Other domestic U.S. approvals/listings pending/

More information

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

SOLID STATE SECURITIES, INC. THE SS90 SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL S S S S S S LISTED L * PATENT PENDING S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT U 99Y9 RESET RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

MMF Six Zone Interface Module

MMF Six Zone Interface Module Installation and Maintenance Instructions I56-900-005 MMF-0-6 Six Zone Interface Module SPECIFICATIONS Normal Operating Voltage: 5- VDC Stand-By Current: ma Alarm Current: 40 ma (assumes all six LEDs solid

More information

FireShield Plus. GE Security. EST Life Safety & Communications Conventional Small Building Solutions. Conventional Fire Alarm Control Panels

FireShield Plus. GE Security. EST Life Safety & Communications Conventional Small Building Solutions. Conventional Fire Alarm Control Panels GE Security EST Life Safety & ommunications onventional Small Building Solutions Overview The FireShield Plus fire alarm family consists of 3, 5 and 10 zone conventional fire alarm s, an integrated DAT/Dialer,

More information

VS1 Intelligent Life Safety System

VS1 Intelligent Life Safety System Vigilant Catalog Small Building Fire Alarm Solutions VS1 Intelligent Life Safety System Overview The Vigilant VS1 intelligent life safety system offers the speed of high-end intelligent processing in a

More information

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual Fire Safety Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual Siemens Building Technologies, Inc. Siemens Building Technologies, Ltd. 8 Fernwood Road 2 Kenview

More information

Installation Instructions Model ABHW-4S

Installation Instructions Model ABHW-4S Installation Instructions Model ABHW-4S Intelligent Audible Base for Sleeping Area with 520Hz Low Frequency Sounder Introduction Application note The Model ABHW-4S audible base from Siemens Industry, Inc.

More information

4100U City and Relay Cards Installation Instructions

4100U City and Relay Cards Installation Instructions 4100U City and Relay Cards Installation Instructions Introduction This publication describes the installation procedure for the following: 4100-6031/6032 City Circuit Cards 4100-6033 Alarm Relay Card Inspecting

More information

IDP-Zone-6 Six Zone Interface Module

IDP-Zone-6 Six Zone Interface Module INSTALLATION AND MAINTENANCE INSTRUCTIONS IDP-Zone-6 Six Zone Interface Module BEFORE INSTALLING If the modules will be installed in an existing operational system, inform the operator and local authority

More information

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA CONVENTIONAL FIRE ALARM CONTROL UNITS MR-2300 SERIES Fire Alarm Control Units Description Secutron s MR-2300 Series fire alarm control panels consist of six and twelve zone models which are equipped with

More information

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1 Matrix2000 User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 s Version: 2.0 Revision: 1 IMPORTANT INFORMATION Limitation of liability It is mandatory, Matrix2000 panel to be installed in accordance

More information

ECC-50/100C. Emergency Command Center

ECC-50/100C. Emergency Command Center ECC-50/100C Emergency Command Center Canadian DF-60815:B Emergency Communications General Fire-lite s ECC-50/100C is a multipurpose emergency voice evacuation panel for fire applications, mass notification

More information

30.45 Electric Release PDRP-2001

30.45 Electric Release PDRP-2001 The PDRP-2001 Fire Alarm Control Panel (FACP) is a six-zone control panel for single and dual hazard deluge and preaction applications. The FACP is compatible with conventional input devices (2-wire or

More information

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE Cookson 100 Elmwood Avenue Crestwood Industrial Park Mountaintop, PA 18707 Phone: 800-233-8366 Fax: 800-526-0841 CornellCookson.com O W N E R S M A N U A L M O D E L S F I R E G A R D M C F I R E G A R

More information

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

THE SS90 SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL S S S S S S OLID TATE ECURITIES, INC S S 90 SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED 99Y9 RESET U L RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0 CFP-105 Fire Alarm Control Panel Installation Manual Version 1.0 WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability

More information

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances UL, ULC Listed* TrueAlert Addressable Notification Appliances Audible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output Features Individually addressed and controlled multi-tone

More information

1. POWERPATH Operation

1. POWERPATH Operation 273 Branchport Avenue Long Branch, NJ 07740 (800) 631-2148 www.wheelockinc.com Thank you for using our products. INSTALLATION INSTRUCTIONS MODEL PS-12/24-6 POWERPATH Use this product according to this

More information

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL Firefly II Multi Voltage RELEASE DEVICES Firefly II & IIB-MV INSTALLATION MANUAL GENERAL DESCRIPTION: S/N The The Cookson Company Firefly II-MV time delay release devices are designed for use on rolling

More information

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual Replace the following pages of Document Number 50734 (I56-993-01/D770-19-00), Revision B with the corresponding revised

More information

TrueAlert Multi-Candela Notification Appliances

TrueAlert Multi-Candela Notification Appliances TrueAlert Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved* Features 24 VDC high intensity notification appliance common features: Xenon strobe with intensity selectable as 135,

More information

Remote NAC Power Supply D7038

Remote NAC Power Supply D7038 Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus

More information

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200 FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200 1.0 General 1.1 Manufacturer Manufacturer of the Fire Alarm Control Panel (FACP) equipment shall be: Digital Monitoring Products, Incorporated 2500 N.

More information

Table 1: dba Ratings for AMT Multitone Signal Typical Anechoic dba at 10 Feet per CAN/ULC S525-07

Table 1: dba Ratings for AMT Multitone Signal Typical Anechoic dba at 10 Feet per CAN/ULC S525-07 273 Branchport Avenue Long Branch, NJ 07740 (800) 631-2148 (USA) Thank you for using our products. (800) 397-5777 (CANADA) www.coopernotification.com GENERAL: INSTALLATION INSTRUCTIONS AMT MULTITONE APPLIANCES

More information

EST2. Installation and Service Manual P/N REV 07 REB 27FEB13

EST2. Installation and Service Manual P/N REV 07 REB 27FEB13 EST Installation and Service Manual P/N 7086 REV 07 REB 7FEB3 DEVELOPED BY COPYRIGHT NOTICE TRADEMARKS UTC Fire & Security 8985 Town Center Parkway Bradenton, FL 340 (94) 739-400 03 UTC Fire & Security.

More information

R Series Remote Annunciators and Expander Installation and Operation Guide

R Series Remote Annunciators and Expander Installation and Operation Guide GE Security R Series Remote Annunciators and Expander Installation and Operation Guide P/N 3100969 REV 1.0 ISS 15JUL08 Copyright Copyright 2008 GE Security, Inc. All rights reserved. This document may

More information

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM DIVISION 26 ELECTRICAL SECTION 26 81 11 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install all equipment and accessories for a complete local, analog addressable, manually and automatically actuated,

More information

E-FSC. Conventional Fire Alarm Control Panels. Standard Features. Overview

E-FSC. Conventional Fire Alarm Control Panels. Standard Features. Overview Edwards Signaling atalog u Fire Alarm ontrol Panels E-FS onventional Fire Alarm ontrol Panels Overview The E-FS fire alarm family consists of 3, 5 and 10 zone conventional fire alarm s, an integrated DAT/Dialer,

More information

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS ECC-50/100(E) Emergency Command Center DF-60734:A4 General Firelite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,

More information

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

SS90 SERIES CONTROLS MODEL C INSTALLATION MANUAL S S S SS O L I D S S90 TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED U L 99Y9 RESET RELEASING DEVICE SOLID STATE SECURITIES, INC. "SS90" SERIES CONTROLS MADE IN THE U.S.A. MODEL

More information

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION Fire Safety Installation Instructions Model SMB- Main Control Board OPERATION The SIEMENS Model SMB- board in each MXL-IQ System controls operations and monitors input device identity, network communication,

More information

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances Fire Control ** IS NORMAL ** :0:pm Mon 9-Feb-9 SY S TE M AC SUPERVISORY TROUB LE SILENCED SUPV TROUBLE SILENCE RESET CONTROL DISC ON NEC T POW ER + V ZONE P WR + 0V ZONE P WR - +IDNE T IDC + - IDNE T IDC

More information

TrueAlert Notification Appliances

TrueAlert Notification Appliances TrueAlert Notification Appliances UL Listed; FM, CSFM and MEA (NYC) Approved* Non-Addressable Audible/Visible Notification Appliances with SmartSync Operation of Strobes and Horns Features Wall mount audible/visible

More information

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R Region Project Page 1 PART 1 - GENERAL 1.1 REFERENCES.1 CAN/ULC-S524-2006, Standard for the Installation of Fire Alarm Systems..2 CAN/ULC-S525-2007, Audible Signal Device for Fire Alarm Systems..3 CAN/ULC-S526-2007,

More information

INSPECTION AND TESTING FORM

INSPECTION AND TESTING FORM INSPECTION AND TESTING FORM Date: Time: SERVICE ORGANIZATION Name: Address: Representative: License No.: MONITORING ENTITY Contact: Monitoring Account Ref. No.: TYPE TRANSMISSION McCulloh Multiplex Digital

More information

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING GENERAL The VEC 25/50 is a state-of-the-art, compact, stand-alone or slave Emergency Voice Evacuation Control. The VEC 25/50 is offered in a self-contained, cost-effective design and includes a 25 Watt,

More information

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone: Cookson Company 1901 South Litchfield Road Goodyear, AZ 85338 Phone: 800-294-4358 www.cooksondoor.com O W N E R S M A N U A L MODEL FIREFLY III EXTENDED PERFORMANCE RELEASE DEVICE TABLE OF CONTENTS INTRODUCTION

More information

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual Fire Safety FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual Siemens Building Technologies, Inc. Siemens Building Technologies, Ltd. 8 Fernwood Road 2 Kenview

More information

RELEASE DEVICE CONTROLS

RELEASE DEVICE CONTROLS RELEASE DEVICE CONTROLS RELEASE DEVICE MODEL C+ INSTALLATION MANUAL UL LISTED CANADIAN LISTED CSFM: 7300-48:00 GENERAL DESCRIPTION: MADE IN THE U.S.A. S/N: The LM0-C+ Release Device/Control Panel is a

More information

Building Name: Our Lady of Sorrows Date: July 10, 2013

Building Name: Our Lady of Sorrows Date: July 10, 2013 1 E1. FIRE ALARM SYSTEM ANNUAL TEST AND INSPECTION REPORT (Reference: 5.1.2) Building Name: Our Lady of Sorrows Date: July 10, 2013 Address 19 Mohns Avenue Petawawa, ON System Manufacturer: Siemens Model

More information

Conventional Fire Alarm Systems

Conventional Fire Alarm Systems Kidde atalog u Small Building Fire Alarm Solutions Technology that saves lives onventional Fire Alarm Systems FX-10RD, FX-10R, FX-5RD, FX-5R OA 6230 Overview Kidde brand conventional fire alarm systems

More information

TrueAlarm ES Analog Sensing

TrueAlarm ES Analog Sensing TrueAlarm ES Analog Sensing UL, ULC, CSFM Listed; FM Approved* Features TrueAlarm addressable sensor base with 520 Hz sounder TrueAlarm sensor bases with 520 Hz tone require a TrueAlarm photoelectric,

More information

R-Series Remote Annunciators and Expanders Installation and Operation Guide

R-Series Remote Annunciators and Expanders Installation and Operation Guide R-Series Remote Annunciators and Expanders Installation and Operation Guide P/N 3100969-EN REV 05 ISS 06MAY13 Copyright Trademarks and patents Manufacturer Version FCC compliance Contact information 2013

More information

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

Use this product according to this instruction manual. Please keep this instruction manual for future reference. 273 Branchport Avenue Thank you for using our products. Long Branch, NJ 07740 (800) 631-2148 INSTALLATION INSTRUCTIONS www.cooperwheelock.com E50 MULTI-CANDELA SPEAKER STROBES GENERAL: Use this product

More information

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD PART 1 - GENERAL PURPOSE This Standard is intended to assure that fire detection/alarm systems at The University of Texas at Austin provide the highest level of fire safety possible. SCOPE This standard

More information

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS SXL Conventional Zone Fire Alarm Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS 4 Zones Expandable to 8 Zones Microprocessor Based Control Factory Programmed Field Configurable 2 Style Y Notification

More information

The MS-4412B/MS-4424B(E) FIRE ALARM CONTROL PANELS

The MS-4412B/MS-4424B(E) FIRE ALARM CONTROL PANELS The MS-4412B/MS-4424B(E) FIRE ALARM CONTROL PANELS 12 Clintonville Road, Northford CT 06472 DOCUMENT 15125 06/24/97 Rev: F1 ECN 97-192 Installation Precautions - Adherence to the following will aid in

More information

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE SAFE A N D SECURE Cornell 100 Elmwood Ave. Crestwood Industrial Park Mountaintop, PA 18707 Tel 800.233.8366 Fax 800.526.0841 Email: cornell@cornelliron.com O W N E R S M A N U A L M O D E L F I R E G A

More information

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number: 109-B Concord Drive Casselberry, FL 32707 407.830.6500 DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72 Pg 1 of 4 Equity One 11180600 Owner/Representative: WO#: _Customer#: 1550 NE Miami Garden Dr

More information

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com LiftMaster 300 Windsor Drive Oak Brook, IL 60523 LiftMaster.com O W N E R S M A N U A L MODELS LM21AFCB LM21AFCBVB B ADVANCE FIRE CONTROL RELEASE DEVICE FM APPROVED TABLE OF CONTENTS INTRODUCTION General

More information

Multi-Application Peripherals and Accessories

Multi-Application Peripherals and Accessories ON UL, ULC Listed FM Approved MultiApplication Peripherals and Accessories Communicating Devices Communications Individually Addressable Devices FEATURES Individually addressable communications over a

More information

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL 26 Aug 2015 V1.8 Page 1 SECTION CONTENTS PAGE NO. 1.0 SYSTEMS DESCRIPTION 1.1 General descriptions 2 1.2 Master Alarm PCB 2 1.3 Zone Display Board 2 1.4

More information

SELECT-A-HORN/STROBE SERIES

SELECT-A-HORN/STROBE SERIES SELECT-A-HORN/STROBE SERIES Features Description Mircom s Select-A-Strobe/Horn Series is designed to comply with the Americans with Disability Act (ADA) and meet UL standard 1971 requirements for emergency

More information

Conventional Releasing Control Panel

Conventional Releasing Control Panel s Data Sheet Fire Safety Products Conventional Releasing Control Panel Pre-Action Deluge Agent-Releasing Fire System Model TXR-320 Remote configurable Up to two (2) hazard areas Operable with the following:

More information