DS7400Xi Addressable Control/ Communicator

Size: px
Start display at page:

Download "DS7400Xi Addressable Control/ Communicator"

Transcription

1 DS7400Xi Addressable Control/ Communicator DS7400Xi DS7400Xi-EXP 110VAC operation 220VAC operation Remotely Programmable WDSRP (Windows Detection Systems Remote Programming Software), allows the systems to be remotely programmed using an IBM PC (or IBM compatible) running Windows and a standard Hayes modem. Using an off-site computer permits diagnostics to be run, systems to be armed, and zones bypassed. This not only reduces service visits to a premise, it also allows quick customer assistance in closing troublesome accounts. Freely Programmable Alpha Display UL Listed,, CSFM Approved 90 PINs The system supports 90 Personal ID Numbers, which are 4 digits in length. Any number of PINS may be designated as master PINs; these are the only PINs which can be used to reprogram PINs. PINs other than the master PINs may be programmed with 7 different levels of authority. These PINs may be restricted from bypassing, testing and disarming the system. Certifications The DS7400Xi is an Addressable Control/ Communicator. It accepts up to 90 Personal ID Numbers (PINs), is keypad or remotely programmable, and has a wide range of features. Features Eight Partitions The DS7400Xi Series may be split up into 8 completely separate systems. Each partition has its own keypads and can have its own reporting ID. Keypads can also be programmed as master keypads, allowing access to all partitions. History Buffer A 400 event history buffer, which can be read at the DS7447 keypad or uploaded to the WDSRP Remote Programming Software, keeps track of Open/Close events, Alarms, Troubles, etc. by time and date. 64 events are in non-volatile memory. Keypad Programmable The system is completely keypad programmable. No need for expensive handheld programmers. UL Standards UL985, Control Units and Accessories - Household System Type UL864. Control Units, System UL1023, Household Burglar Alarm System Units UL365 and UL464, Police Station Alarm Units Connection Grades AA* and A UL294, Central Station Alarm Units UL1076, Proprietary Alarm Units UL464 and UL609, Local Alarm Units ULC Listed CSFM * Grade AA, UL Listing is in compliance when used with Motient/ARDIS sm Transceiver or other selected communications systems. Refer to current UL installation approvals in the DS7400Xi Reference Guide. S306-M89 Commercial Fire Approved Meets commercial fire requirements when used with the DS7420i (Dual Phone Line/Bell Supervision Module), DS7447 Alpha Numeric Keypad with red graphic, and AETR-16 (enclosure for transformer). The DS7400Xi has 8 on-board zones may be used as Class B (Latching) input loops and will accept up to 20 two-wire smoke detectors (such as DS250 Series) each. Addressable zones support 4-wire and Multiplex MX280 smoke detectors. Suitable for installation in NFPA 72 applications as applies to Local, Central Station, Remote Station, Sprinkle Supervisory, and Waterflow. 99

2 Patents 5,268,668 5,302,941 Basic Functions LED and Alpha Keypad Support Zones Automatic Arming/ Delayed Arming Common Area Partitioning Smoke Detector Alarm Verification DS7445 LED keypad Provides an LED per zone (for main board zones 1-8 only), plus eight system status LEDs that indicate conditions such as armed, fire alarm, and trouble. DS7447 Alpha Numeric keypad Two line display allows 16 characters of custom text to be programmed for zone and partition descriptions. The user can adjust the sounder volume and backlight intensity using easy twobutton commands. The DS7447 is required for system programming. LED and LCD keypads may be mixed in the same system. The DS7400Xi accepts up to 128 zones. These zones may consist of eight hardwired zones, plus the remaining addressable zones. Any of these zones may be programmed to follow one of 15 programmable zone functions. An automatic arming time can be programmed for each partition each day. The user may use Delayed Arming to override automatic arm time or to specify a time for the panel to arm. One partition can be programmed to follow the arming state of some or all of the other partitions. The common area arms only when all partitions that are linked to it are armed. This allows for protection of shared areas such as foyers and entry-ways, while still maintaining separate partitioning. The DS7400Xi Series may be programmed to perform an automatic reset of the smoke detectors, should an alarm occur. If a second alarm occurs within the verification window, an immediate fire alarm results. This reduces potential false alarms, while still providing fast response to an alarm. Custom Arming Configurations Answering Machine Override Three Telephone Numbers EE Memory Output Functions Input/Output Cross Matrixing Octal Relay Modules Addressable Bus Outputs Control Panels The system can be programmed to arm in different configurations providing a means of automatically bypassing a group of zones. The DS7400Xi has a built-in answering machine override function. No external hardware is required. The system supports two 20-digit telephone numbers with a three or four digit account code. Each of the two phone numbers can be configured for the type of communication format and choice of pulse or tone dialing. The third phone number used for remote programming. The panel uses EEPROM technology; thereby, allowing it to retain all program memory as well as the arm/disarm state through a total power failure. There is also a delay on power restore to prevent false alarms from space sensors that may take several minutes to become operational. None of the system programming or user codes will be lost. Output Functions can be programmed to follow system events or to follow one or two specific zones in a cross matrix fashion (see Input/Output Cross Matrixing). These Output Functions can be programmed to control octal relay outputs or addressable bus outputs. Input/Output cross matrixing allows Output Functions to follow the status of specific input zones. Outputs can be programmed to follow any combination of one or two zones, open or closed, with the system armed or disarmed. The DS7400Xi supports up to two DS7488 Octal Relay Modules or two DS7489 Solid State Output Modules. Each module supplies 8 relay or solid state outputs to follow system events or to follow programmed Output Functions from the DS7400Xi. The DS7400Xi supports up to 20 DS7465 Input/Output modules. These modules are connected to the addressable bus and provide one input loop and one Form C output relay. The input loop operates the same as all other addressable inputs. The output loop can be programmed to follow Output Functions. (888) Detection Systems, Inc. 100

3 Anti-Takeover Protection Two Independent Entry Delays Easy Function Key User Interface Flexible Digital Communication All or part of the programming may be locked so the program cannot be changed should someone attempt to takeover the account. Patented BusLoc anti-takeover circuitry imbeds a secret code into the addressable devices, prohibiting the control from being replaced using these devices. Zones may be programmed to select from one of the two entry delay times. This allows the selection of a longer entry delay time for zones that are located a long distance from the keypad. Six labeled function keys eliminate the need for multi-button commands. Enter a PIN followed by the function key to perform functions such as arming, disarming, and resetting smoke detectors. The interface provides new users with easy to follow procedures. The interface does not use cumbersome menu driven formats, so expert users can quickly access the items they need. A programmable Quick Arm feature allows users to turn the system on without a PIN. However, a PIN is required to turn off the system, silence alarms, or perform system tests. Residential Mode requires a PIN to disarm the system, silence alarms, and reset the system. The communicator will work into most alarm receivers that are in use today, and support 3/1, 4/1, 4/2, Contact ID, SIA, BFSK digital communicator formats and pager format. The pager format allows the control to dial a digital pager service and leave a numeric message representing the account number and event code. Technical Specifications Operating Temperature Communicator +32 F to +120 F (0 C to +49 C) Will report to two phone numbers with full single, double and backup reporting. Communicates in 3/1, Ext., 3/1 with Parity, 3/1 Ext. with Parity, 4/1, 4/2, BFSK, Contact ID, and SIA digital communicator formats and pager format. The pager format allows the control to dial a digital pager service and leave a numeric message representing the account number and event code. FCC registration Number is ESVUSA AL-E The ringer equivalence is 0.1 B. Enclosures AE1/AE2 The DS7400Xi has two standard enclosures: (AE1 - is a gray enclosure, and AE2 is a red enclosure). Both are manufactured from 20 Ga., cold-rolled steel, and measure (WxHxD) 12.5 in. x 14.5 in. x 3 in. (320 cm x 370 cm x 76 cm). A keyed lock is included, and these enclosures have provision for an optional tamper switch for monitoring the door. AE3/AE4 The AE3 is a large gray enclosure and the AE4 is a large red enclosure. Both are manufactured from 18 Ga., cold-rolled steel, and measure (WxHxD) 15 in. x in. x 4.25 in. (380 cm x 530 cm x 108 cm). A keyed lock is included, and these enclosures have provision for an optional tamper switch for monitoring the door. Lightning Protection Burglar/Fire Zone Inputs MOVs and spark gaps provide protection from lightning surges and static discharges. Number of circuits: eight circuits on board End of line resistor: 2.21k ohms 101 Detection Systems, Inc. (888)

4 Fire Signal Initiating Circuits (2 wire mode) Fire circuits will work with 2 or 4-wire detectors and have optional alarm verification. Number of circuits: eight circuits on board, expandable to 16 Type of circuit: Class B, latching End of line resistor: 2.21k ohms Supervisory current: 5 ma Minimum current for alarm: 12 ma Maximum short circuit current: 22 ma Maximum circuit resistance: 60 ohms Circuit voltage range: 8.5 to 14.1 VDC Max. impedance for alarm: 1000 ohms Maximum detectors per zone: 20 detectors (2-wire) Total detector standby current: 2.5 ma Outputs The system provides three outputs that are individually programmable and may be controlled by alarms, access control, ground start, smoke detector reset, or the control s arming state. The DS7400Xi has three outputs expandable to 39, and DS7400Xi16-EXP is expandable to 15. Alarm Output Normally Open, 1.75 Amp contact connected to auxiliary power. Programmable Output 1 Solid state current sink (1 Amp Max.). Can be used for alarm, arming state, or access control. Programmable Output 2 Solid state voltage source (500 ma Max.). Can be used for alarm, arming state, or access control. Keypads Number of keypads: 15 keypads Max. wire length each: 1000 ft. (300 m) Max. wire length total in system: 5000 ft. (1800 m) Wire type: 4 conductor AWG. Note: No more than 2 keypads per 1000 ft. (300 m) run. Optional Accessories DS7104 Line Reversal Module Provides a reverse polarity output for direct connection applications. Provides both a maintained and alternating output. Power Requirements Input: 18 VAC, 50 VA, 50 or 60 Hz Total power output: 12 VDC, 2.5 Amps Keypad regulated power: 12 VDC, 1.0 Amps UL Listed Auxiliary power: 12 VDC, 1.0 Amps UL Listed Alarm Power Output: 1.75 Amps Optional Standby Battery (P334): 12 V, 7.0 AH (can support up to 35 AH) Programmable Outputs 110 VAC and 220 VAC transformers available DS7111i Dual Phone Monitor Provides two phone line supervision and switching with trouble output. Connects to one zone of control. Not for use in Commercial Fire applications. DS7412 RS232 Interface Module Provides the ability to print history events either real time or via a keypad command. Connects to a standard serial printer. Also allows direct connect programming using the WDSRP software. DS7420i Dual Phone line/bell Supervision Module Provides a supervised 12 volt bell output, dual phone line supervision, one Class A (Style D) Commercial Fire Zone and a latched Form C relay output. 1 per system. DS7430 Multiplex Bus Driver Provides an expansion bus for connection of multiplex devices. One per system. (888) Detection Systems, Inc. 102

5 DS Input Remote Module Provides eight supervised input zones for connection of additional Normally Open or multiplex bus. Requires use of DS7430 or DS Input Direct Module Provides eight supervised input zones for connection of additional Normally Open or Normally Closed inputs. These eight zones support 2-wire smoke detectors when configured as fire zones. Connects directly to DS7400Xi in place of multiplex bus. Cannot be used with DS7430 or 1 per system. DS7445 LED Keypad Eight Zone LEDs. Eight system status LEDs. Sounder volume is controlled via simple two button commands. DS7447 Alpha Numeric Keypad Displays two lines of 16 characters of custom text to be programmed. The Alpha information is remotely downloadable and it can be programmed by the installer at the keypad. Sounder volume and backlight intensity is controlled via simple two button commands. DS7450 Flush Mount Multiplex Contact Provides replacement for conventional dry contacts. Reports actual multiplex address to the control panel. Requires DS7430 or DS7452 Surface Mount Multiplex Contact Provides replacement for conventional dry contacts. Reports actual multiplex address to the control panel. Requires DS7430 or DS7455 Surface Mount Single Multiplex Contact Point Provides replacement for conventional dry contacts. Reports actual multiplex address to the control panel. Occupies 1 zone. Requires DS7430 or DS7457 (DS7457i, DS7457iF) Single Zone Multiplex Input Module Provides one supervised input zone for connection of conventional Normally Open or multiplex bus. Requires DS7430 or DS7460 (DS7460i) Two Input Module Provides two supervised input zones for connection of conventional Normally Open or addressable bus. Requires DS7430 or DS7461i Single Input Module Provides one supervised input zones for connection of conventional Normally Open or addressable bus. Requires DS7430 or DS7465 (DS7465i) Input/Output Module Provides one supervised input for connection of conventional Normally Open or Normally Closed inputs. Also provides one Form C relay which can be programmed to follow system events of the status of specific zones. Connects to addressable bus. Up to twenty (20) per system for the DS7400Xi. Requires DS7430 or MX280 Series Smoke Detectors Multiplex Photoelectric Smoke detectors with Chamber Check Self Diagnostics. MX280TH includes 135 heat sensor. MX280THL includes 135 heat sensor plus low temperature sensor. MX775i Addressable PIR A 50 ft. Microprocessor-based wall mount, addressable PIR detector. Uses Motion Analyzer II Processing. Includes Motion Monitor and three sensitivity settings. Internally pointable field replaceable mirrored optics provide three coverage patterns. Requires use of DS7430 or DS7436, occupies one zone. MX794i Long Range Multiplex PIR Intrusion Detector A 200 ft. Microprocessor-based wall mount, DIP switch programmable PIR intrusion detector. Uses Motion Analyzer II Processing and has three sensitivity settings. Field replaceable mirrored optics provide three coverage patterns. Requires use of DS7430 or 103 Detection Systems, Inc. (888)

6 MX835 Addressable TriTech PIR/Microwave Detector with Animal Immunity A 35 ft. PIR/Microwave detector which includes PIR/Microwave supervision features. Requires DS7430, occupies one zone. DS7488 Octal Relay Module Provides eight Form C relay outputs. These outputs are fully programmable and can be activated by several different system events. Two per system (DS7400Xi). AETR-16 Enclosure Mounts over standard electrical outlet. Provides mechanical protection for transformer and wiring connections. MX934i Addressable PIR A 35 ft. Microprocessor-based wall mount, dipswitch programmable PIR detector. Uses Motion Analyzer II Processing and has two sensitivity settings. Internally pointable field replaceable mirrored optics provide four coverage patterns. Requires use of DS7430 or DS7436, occupies one zone. MX938i Addressable PIR A 60 ft. diameter Microprocessor-based ceiling mount, addressable PIR detector. Uses Motion Analyzer II Processing. Includes three sensitivity settings field replaceable mirrored optics. Requires use of DS7430 or DS7436, occupies one zone. MX950 Addressable PIR A 50 ft. Microprocessor-based dual technology wall mount, 4-wire addressable PlR/microwave detector. Supervision features include anti-masking protection and Motion Monitor. Four coverage patterns using field replaceable fresnel lenses. Requires use of DS7430 or DS7436, occupies one zone. DS7480 Bell Supervision Module Provides power and supervision for one endof-line supervised indicating appliance circuit. Connects to programmable alarm output of DS7400Xi series. Indicates trouble condition using a Form C relay connected to one zone. DS7481 Single Phone Line Monitor Monitors one phone line. Provides a normally open relay output which closes upon phone line failure. P/N 29329H Detection Systems, Inc. 130 Perinton Parkway, Fairport, New York (585) Cust. Service (888) Fax: (585) Faxback: (800)

Reference Guide for the DS7400Xi (Version 3+) Control/Communicator

Reference Guide for the DS7400Xi (Version 3+) Control/Communicator eference Guide for the DS7Xi (Version +) Control/Communicator Armed Status Power Fire Armed Status Power Fire Perimeter Supervisory Bell Silenced Trouble 5 6 7 8 On On Off Off Turning On (arming) your

More information

D8125MUX. Operation and Installation Guide. Multiplex Bus Interface

D8125MUX. Operation and Installation Guide. Multiplex Bus Interface D8125MUX EN Operation and Guide Multiplex Bus Interface EN 2 D8125MUX Operation and Guide Contents Contents Contents...2 1.0 Introduction...3 1.1 Description...3 1.2 Programming...3 1.3 Listings...3 2.0

More information

Solution-8248 Installation Manual ISSUE 1.16

Solution-8248 Installation Manual ISSUE 1.16 Solution-8248 Installation Manual ISSUE 1.16 MA880I Solution- 8248 This page has been included for you to cut out and insert into the spine of the folder Installation Manual ISSUE 1.16 www.dsworld.com

More information

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2 Architectural & Engineering Specifications Control Panel 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality assurance...

More information

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200 FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200 1.0 General 1.1 Manufacturer Manufacturer of the Fire Alarm Control Panel (FACP) equipment shall be: Digital Monitoring Products, Incorporated 2500 N.

More information

P Zone Expandable Hybrid Security System

P Zone Expandable Hybrid Security System Page 1 of 11 up to 8 hardwired keypads and 4 wireless keypads 4 hardwired keypads available with zone input PWLS910 wireless handheld keypad added wireless control is provided by - PWLS908 wireless panic

More information

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.

More information

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...

More information

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi 50 (P/N 10-071) is a state-of-the-art true intelligent digital peer-to-peer modular suppression control system.

More information

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing Control Panels Control Panels for Commercial Applications Control panels provide the central processing and logic for an integrated system. In a typical system, there are four major functions: inputs,

More information

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description MODUL-R FIRE ALARM CONTROL PANELS MR-2900/MR-2920 Addressable Fire Alarm Control Panels Description MR-2900 Fire Alarm Control Panel The MR-2900 fire alarm system control unit is the heart of a sophisticated

More information

Addressable Fire Alarm Control Panel

Addressable Fire Alarm Control Panel PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT

More information

D7024 Fire Alarm Control Panel

D7024 Fire Alarm Control Panel D7024 Fire Alarm Control Panel The D7024 offers accurate, consistent performance with a feature set that elevates this panel to the top of its class. Fire systems you can rely on. D7024 24V Addressable

More information

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014 January 16, 2014 Release Control Panel 290a 1. Description The Viking VFR400 is a microprocessor based releasing control panel for use on preaction, deluge, Surefire, Firecycle multicycle sprinkler systems,

More information

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi (P/N 10-068) is a state-of-the-art true intelligent digital peer-topeer modular suppression control system. It is ideal for

More information

Model 17A00 Expansion Enclosure

Model 17A00 Expansion Enclosure HOME AUTOMATION, INC. Model 17A00 Expansion Enclosure Installation Manual Document Number 17I00-1 Rev A March, 2002 Home Automation, Inc. Model 17A00 Expansion Enclosure Installation Manual Document Number

More information

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. TABLE OF CONTENTS... P.1 2. GENERAL DESCRIPTION... P.2... 3. STANDARD AND OPTIONAL PARTS LIST... P.2... 4. FEATURE

More information

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION...2 STANDARD AND OPTIONAL PARTS LIST...2 FEATURE DEFINITIONS...3 TERMINAL DRAWING AND SPECIAL NOTES...4

More information

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E... 5$1*(5( DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS General Description... 2 Standard and Optional Parts List... 2 Feature Definitions... 3 Comments about the 8600E... 4 Terminal

More information

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM SECURITY ACCESS AND SURVEILLANCE SECTION 13850 VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM ADEMCO Group 165 Eileen Way Syosset, New York 11791 1-800-645-7568 SECTION 13850 DETECTION

More information

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 XL-2G Gold Product Overview 7 Zones (6 programmable + panic or keyswitch zone) Fast Loop Response

More information

DS7465i. Installation Instructions. Input/Output Module

DS7465i. Installation Instructions. Input/Output Module DS7465i EN Installation Instructions Input/Output Module DS7465i Installation Instructions.0 Introduction EN 2.0 Introduction The DS7465i Input/Output Module operates with compatible multiplex systems.

More information

DOOR MONITORING/DURESS SYSTEM

DOOR MONITORING/DURESS SYSTEM SECTION PART 1 - GENERAL 1.1 RELATED SECTIONS A. Comply with the requirements of Section 27 05 00 Common Work Results for Communications. 1.2 DEFINITIONS A. Not used. 1.3 DESCRIPTION OF SYSTEM: A. Provide

More information

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel Designed to integrate seamlessly with, access control, and ADEMCO s full range of fire and burglary components, the

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

DS860 Surface or Corner Mount TriTech PIR/Microwave Detector

DS860 Surface or Corner Mount TriTech PIR/Microwave Detector TriTech PIR Microwave Detectors 29782M DS860 Surface or Corner Mount TriTech PIR/Microwave Detector Prod. ID DS860 PIR signal processing Motion Analyzer II uses multiple thresholds and timing windows to

More information

VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access

VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access Designed to integrate seamlessly with, access control and ADEMCO s full range of fire and burglary components, the VISTA-32FB provides the ultimate protection of life and property. The UL listed Fire and

More information

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906 s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING -961212-0004 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. ( 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2) Connect

More information

Concerns: Affects: Dated: June 12, SECTION 1: GENERAL Scope Work Included... 3

Concerns: Affects: Dated: June 12, SECTION 1: GENERAL Scope Work Included... 3 Technical Service Note Detection Systems, Inc. Fairport, New York 14450-9199 Technical Service (800) 374-7454 Sales: (800) 289-0096 and (585) 223-4060 Fax: (585) 223-9180 Concerns: Affects: Dated: June

More information

Installation Manual Premier 412/816/832. Issue 10

Installation Manual Premier 412/816/832. Issue 10 Installation Manual Premier // Issue 0 Premier // Installation Manual 5. Operating the System Introduction Before attempting to operate the alarm system ensure you have familiarised yourself with all the

More information

good things in small packages

good things in small packages FireShield Control Panels good things in small packages life safety for small buildings and shops A perfect arrangement FireShield offers the very best conventional fire alarm technology available, with

More information

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION... 2 2. STANDARD AND OPTIONAL PARTS LIST... 2 3. FEATURE DEFINITIONS... 3 4. TERMINAL DRAWING AND SPECIAL

More information

Multiplex Eight Input Remote Modules

Multiplex Eight Input Remote Modules Multiplex Eight Input Remote Modules 1.0 Introduction These instructions cover the installation of the D7042/D7042B Eight Input Remote Modules in a fire system supervised by an FPD-7024 Fire Alarm Control

More information

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging 1.1 Specifications System Introduction S E C T I O N 1 Control Panel Specifications Flexible Zone Configuration: 8 Fully Programmable Zones 38 Access Codes: 32 User, 1 System Master, 2 Partition Master,

More information

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector ISC-PDL1-W18G-H EN Installation Instructions Professional Series Dual Detector 1.0 General Information 1.1 Unlock and remove the cover The ISC-PDL1-W18x Professional Series TriTech Detectors are exceptionally

More information

Control/Communicator

Control/Communicator Architectural & Engineering Specifications Control/Communicator 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality

More information

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2 INSTALLATION 3 Mounting the Panel... 3 Mounting the Keypad... 3 Auxiliary Power Connection... 3 PGM Terminal Connections... 3 Bell/Siren Connection... 3 Keypad

More information

MODEL 5104B. Installation and Operation Manual. Fire Communicator. Part Number E, 09/04

MODEL 5104B. Installation and Operation Manual. Fire Communicator. Part Number E, 09/04 MODEL 5104B Fire Communicator Installation and Operation Manual Part Number 151053 E, 09/04 Content Section 1 Introduction... 1-1 1.1 Feature... 1-1 1.2 Accessory Devices... 1-2 1.3 About This Manual...

More information

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA CONVENTIONAL FIRE ALARM CONTROL UNITS MR-2300 SERIES Fire Alarm Control Units Description Secutron s MR-2300 Series fire alarm control panels consist of six and twelve zone models which are equipped with

More information

Installation Guide. Control/Communicator

Installation Guide. Control/Communicator Installation Guide Control/Communicator 33120G Page 2 Copyright 2001 Radionics Contents 1.0 Introduction... 5 1.1 Listings and Approvals... 5 1.1.1 Fire... 5 1.1.2 Burglary... 5 1.2 FCC Notice... 5 1.2.1

More information

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel DS9400 Series EN Release Notes for Firmware V2.07 Fire Alarm Control Panel DS9400 Series Release Notes for Firmware V2.07 Trademarks Trademarks Gentex is a trademark of Gentex Corporation, Fire Protection

More information

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM SECURITY ACCESS AND SURVEILLANCE SECTION 13850 VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM ADEMCO Group 165 Eileen Way Syosset, New York 11791 1-800-645-7568 SECTION 13850 DETECTION

More information

Fire Alarm Control/Communicator

Fire Alarm Control/Communicator Fire Alarm Control/Communicator Operation and Installation Guide Power Alarm Trouble Silenced Radionics FIRE CONTROL/COMMUNICATOR R 31499F Page 2 2000 Radionics. Contents Contents 1.0 Notices... 9 1.1

More information

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1 1.1 PC5015 Specifications System Introduction S E C T I O N 1 Flexible Zone Configuration: 8 Fully Programmable Zones 38 Access Codes: 32 User, 1 System Master, 2 Partition Master, 2 Duress and 1 maintenance

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING 48ESEP-01 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)

More information

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM SECURITY ACCESS AND SURVEILLANCE SECTION 13850 VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM ADEMCO Group 165 Eileen Way Syosset, New York 11791 1-800-645-7568 SECTION 13850 DETECTION

More information

WIRELESS CONTROLS & DETECTORS

WIRELESS CONTROLS & DETECTORS WIRELESS CONTROLS & DETECTORS WLS908 Panic Pendant Press 2 buttons for 2 seconds to initiate a panic alarm Water-resistant Pendant test function Supervised for low battery Each pendant is a wireless zone

More information

System Introduction. 1.1 Specifications S E C T I O N 1

System Introduction. 1.1 Specifications S E C T I O N 1 System Introduction S E C T I O N 1 1.1 Specifications Control Panel Specifications Flexible Zone Configuration: 8 Fully Programmable Zones 37 Access Codes: 32 User, 1 System Master, 2 Partition Master

More information

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel DS3MX-E-I EN Installation Guide 3 Mini Control Panel DS3MX-E-I Installation Guide 1.0 General Information EN 2 1.0 General Information The DS3MX is a three zone mini control panel, which can be installed

More information

INSTALLATION MANUAL PC15OO

INSTALLATION MANUAL PC15OO INSTALLATION MANUAL PC15OO This device complies with Parts 15 and 68 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2)

More information

EVO192 v3.0 Fire and Burglary What s New

EVO192 v3.0 Fire and Burglary What s New EVO192 v3.0 Fire and Burglary What s New Compatibility: EVO192 v3.0 TM50 v1.31 K641 v2.41 Overview: CP-01 Compliancy Wiring Diagram The following sections/options have been added to the EVO192 panel. They

More information

TABLE OF CONTENTS TABLE OF CONTENTS 1

TABLE OF CONTENTS TABLE OF CONTENTS 1 TABLE OF CONTENTS TABLE OF CONTENTS 1 FEATURES 2 Keypad Programmable... 2 EEPROM Memory... 2 Static/Lightning Protection... 2 Supervision... 2 Operation... 2 SPECIFICATIONS 2 PC1550 Control Panel... 2

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING -961212-0004 SOFTWARE VERSI 3.10 CTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)

More information

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: -961112-0002 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3

More information

INSTALLATION MANUAL PC56O. Version 1.OA

INSTALLATION MANUAL PC56O. Version 1.OA INSTALLATION MANUAL PC56O Version 1.OA TABLE OF CONTENTS INTRODUCTION 3 Features... 3 Specifications... 3 INSTALLATION 4 Mounting the Control Panel... 4 Mounting the Keypad... 4 Wiring... 5 Burglary Zone

More information

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION...P.2 2. STANDARD AND OPTIONAL PARTS LIST...P.2 3. FEATURE DEFINITIONS...P.3 4. TERMINAL DRAWING AND

More information

Conventional Releasing Control Panel

Conventional Releasing Control Panel s Data Sheet Fire Safety Products Conventional Releasing Control Panel Pre-Action Deluge Agent-Releasing Fire System Model TXR-320 Remote configurable Up to two (2) hazard areas Operable with the following:

More information

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description CONVENTIONAL FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped with

More information

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147) -961112-0003 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3

More information

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216 16-128 Zone Control Panel PC4020 16 zones on main control panel supports up to 16 hardwired keypads Expandable up to 128 zones using hardwire, wireless modules and addressable zones COMBUS hardwired expansion

More information

OJD ITB No Attachment E Duress Alarm Equipment Specifications

OJD ITB No Attachment E Duress Alarm Equipment Specifications Duress Alarm Equipment Specifications PART 1 GENERAL 1.1 SECTION INCLUDES A. Duress devices. B. Alarm control panel. C. Signaling devices. 1.2 REFERENCE STANDARDS A. NFPA 70 - National Electrical Code;

More information

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide Product Overview The IntelliKnight 5820XL is an intelligent addressable fire alarm control panel designed for flexibility and reliability.

More information

D1255RB/D1256RB/D1257RB

D1255RB/D1256RB/D1257RB D1255RB/D1256RB/D1257RB EN Installation Instructions Fire Keypads and Fire Alarm Annunciator D1255RB/D1256RB/D1257RB Installation Instructions Listings and Approvals Listings and Approvals UL 365 UL 609

More information

30.45 Electric Release PDRP-2001

30.45 Electric Release PDRP-2001 The PDRP-2001 Fire Alarm Control Panel (FACP) is a six-zone control panel for single and dual hazard deluge and preaction applications. The FACP is compatible with conventional input devices (2-wire or

More information

Control/Communicator Installation Manual

Control/Communicator Installation Manual DAS NETWORX NX-12 Control/Communicator Installation Manual General Description...2 Ordering Information...2 Option Definitions...3 Programming the LED Code Pads...5 Programming the NX-12...9 Types of Programming

More information

Flair 500 Series Annunciators

Flair 500 Series Annunciators Flair 500 Series s Basics Flair Multi-Zone s (MZAs) are fully functional, flexible, programmable micro controller based alarm control panels. They can be used independently d or in conjunction with other

More information

System Overview. PC4020 v3.3

System Overview. PC4020 v3.3 System Overview PC4020 v3.3 The MAXSYS system meets today s challenges with the seamless integration of security, access control, fire alarm, automation, and intercom features that single function systems

More information

INTELLIGENT FIRE ALARM CONTROL PANEL

INTELLIGENT FIRE ALARM CONTROL PANEL INTELLIGENT FIRE ALARM CONTROL PANEL FX-2000 SERIES Description Mircom s FX-2000 Series Intelligent Analog Fire Alarm Control Panel is designed to provide maximum flexibility of analog system requirements

More information

Integrated Security Solutions

Integrated Security Solutions Integrated Security Solutions Table of Contents Control Panels 4 Keypads 8 Communication Modules 16 I/O Expanders 20 Door Control 24 Home Automation 25 RF Receivers 26 2 Our integrated security solutions

More information

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160 All-In-One Wireless Security System V3.2 Programming Guide Model # MG6130 / MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC Take Fire Protection to the Next Level Fire Products from DSC AFD2000 Addressable Fire Control Panel Series Provides Maximum Flexibility The new AFD2000 is a completely programmable series of addressable,

More information

System Introduction. 1.1 Specifications

System Introduction. 1.1 Specifications System Introduction S E C T I O N 1 1.1 Specifications Downloading Software Support PC585 uses DLS-1 v6.5 and up. Flexible Zone Configuration Four fully programmable zones; system expandable to eight zones

More information

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K PEGAsys Multi-Loop Intelligent Suppression Control System A UTC Fire & Security Company Effective: March 2007 K-76-028 FEATURES UL Listed CSFM Approved MEA Approved Peer-to-Peer Networking (to 32 nodes)

More information

FMR Installation Instructions. Addressable Fire System Controller

FMR Installation Instructions. Addressable Fire System Controller FMR-7033 EN Installation Instructions Addressable Fire System Controller EN 2 FMR-7033 Installation Instructions Contents Contents Contents...2 1.0 Introduction...3 2.0 Description...3 3.0 Device Mounting...3

More information

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION...P.2 2. STANDARD AND OPTIONAL PARTS LIST...P.2 3. FEATURE DEFINITIONS...P.3 4. TERMINAL DRAWING AND

More information

PRODUCT CATALOG. Concord Family Product Catalog. December 1999

PRODUCT CATALOG. Concord Family Product Catalog. December 1999 PRODUCT CATALOG Concord Family Product Catalog December 1999 Interactive Technologies, Inc. 2266 Second Street North, North Saint Paul, MN 55109 800/777-5484 www.itii.com CONTROL PANELS Concord Express

More information

INSTALLATION GUIDE XR100 SERIES COMMAND PROCESSOR PANEL

INSTALLATION GUIDE XR100 SERIES COMMAND PROCESSOR PANEL INSTALLATION GUIDE XR100 SERIES COMMAND PROCESSOR PANEL MODEL XR100 SERIES ACCESS CONTROL COMMAND PROCESSOR PANEL INSTALLATION GUIDE Contains installation instructions for use with the Model XR100 and

More information

System Manual W A R N I N G. PC6O1O Software Version 2.1

System Manual W A R N I N G. PC6O1O Software Version 2.1 System Manual W A R N I N G This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual

More information

Reference Guide for the D7024 Control/Communicator

Reference Guide for the D7024 Control/Communicator Reference Guide for the D7024 Control/Communicator 1997 Radionics, Inc., Salinas, CA, U.S.A. All rights reserved. The Radionics logo is a registered trademark of Radionics, Inc., Salinas CA, U.S.A. Radionics,

More information

Integrated Security Solutions

Integrated Security Solutions Integrated Security Solutions Table of Contents Control Panels 4 Keypads 8 Communication Modules 16 I/O Expanders 20 Door Control 24 Home Automation 25 RF Receivers 26 3 Our integrated security solutions

More information

ACP10 & ACP50 Security Systems

ACP10 & ACP50 Security Systems ACP10 & ACP50 Security Systems System Configuration LCD Keypad LCD Keypad LED Keypad LED Keypad 4-wire Bus ACP10 & ACP50 AEX10* AEX10* AEX10* AEX10* * ACP50 Only Control Panels The ACP10 control panel

More information

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS MODEL XR5FC/XR5SL COMMAND PROCESSOR INSTALLATION GUIDE FCC NOTICE This equipment generates and uses radio frequency energy and, if not installed

More information

PC4020 v3.2 Installation Manual DLS-3 v1.3

PC4020 v3.2 Installation Manual DLS-3 v1.3 PC4020 v3.2 Installation Manual DLS-3 v1.3 WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer.

More information

D2412 Control / Communicator Installation Manual

D2412 Control / Communicator Installation Manual D2412 Control / Communicator Installation Manual C Notice The material and instructions covered in this manual have been carefully checked for accuracy and are presumed to be reliable. However, Radionics,

More information

LifeAlarm Fire Alarm Control Panels

LifeAlarm Fire Alarm Control Panels LifeAlarm Fire Alarm Control Panels UL, ULC Approved* Features Control panel operator convenience features: Wide viewing angle 2 x 20 (40 character) alphanumeric LCD and dedicated LEDs provide convenient

More information

Fire Control/Communicator

Fire Control/Communicator Operation and Installation Manual Fire Control/Communicator 1 2 3 4 5 12V AC,20V A, 60Hz or +24V DC 12V AC, 20V A, 60Hz or -24V DC EARTH GND BATTERY - BATTERY + 6 INITIATING A1-7 INITIATING A2-8 INITIATING

More information

Remote NAC Power Supply D7038

Remote NAC Power Supply D7038 Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus

More information

INSTALLATION MANUAL DV8OOO. Software Version 1.0

INSTALLATION MANUAL DV8OOO. Software Version 1.0 INSTALLATION MANUAL DV8OOO Software Version 1.0 *DVACS is a registered trade mark of Electro Arts Limited and covers a wide variety of products. Full DVACS compatability applies only when the Sur-Gard

More information

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX PROGRAMMING GUIDE SPECTRA CONTROL PANELS V1.2 1725, 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX TABLE OF CONTENTS HOW DO I PROGRAM THE SYSTEM?... 4 Single Digit Data Entry Method (Hexadecimal

More information

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide Digiplex System V2.14 / V2.2ACC Control Panel Programming Guide Table of Contents Getting Started...2 What Do I Do First?...2 How Do I Program the Control Panel?...2 Single Digit Entry Method...2 Multiple

More information

Copyright Detection Systems PTY Ltd. Unit 21, 45 Gilby Road Mount Waverley, Victoria 3149, Australia Fax:

Copyright Detection Systems PTY Ltd. Unit 21, 45 Gilby Road Mount Waverley, Victoria 3149, Australia Fax: Detection Systems PTY Ltd. Unit 21, 45 Gilby Road Mount Waverley, Victoria 3149, Australia 61 3 9558 8088 Fax: 61 3 9558 8089 Copyright 1995-97 Detection Systems PTY Ltd. Unit 2, The Riverside Centre 148

More information

NETWORK FIRE ALARM CONTROL PANEL. Features

NETWORK FIRE ALARM CONTROL PANEL. Features NETWORK FIRE ALARM CONTROL PANEL FX-2009-12N Description FX-2009-12N in a BB-5008 enclosure. Mircom s FleX-Net TM FX-2009-12N Network Fire Alarm Control Panel offers modular components to meet a wide variety

More information

D7212 Control/Communicator Operation and Installation Manual

D7212 Control/Communicator Operation and Installation Manual D7212 Control/Communicator Operation and Installation Manual Notice The material and instructions covered in this manual have been carefully checked for accuracy and are presumed to be reliable. However,

More information

INSTALLATION GUIDE XTLN-WIFI PANEL

INSTALLATION GUIDE XTLN-WIFI PANEL INSTALLATION GUIDE XTLN-WIFI PANEL MODEL XTLN-WiFi INSTALLATION GUIDE FCC NOTICE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of

More information

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE The Door Switch 11772 Westline Industrial Drive St. Louis, Mo 63146 (877) 998-5625 www.thedoorswitch.com Patent No. RE42,991 and RE44,039 CONTROL PANEL TRANSFORMER (SUPPLIED WITH CONTROL PANEL) NOTIFICATION

More information

INSTALLATION MANUAL. PC3OOO Version 7.6W

INSTALLATION MANUAL. PC3OOO Version 7.6W INSTALLATION MANUAL This device complies with Parts 15 and 68 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device

More information

D720 and D1255 Command Centers

D720 and D1255 Command Centers Command Centers and Keypads D720 and D1255 Command Centers 33704G The D720 and D1255 Command Centers are low profile, surface mount units that can annunciate events from the 9000 Series Control/Communicators

More information

DS7400Xi (version 3+) Security System User s Guide

DS7400Xi (version 3+) Security System User s Guide DS7400Xi (version 3+) Security System User s Guide An instruction guide for your alarm system when used with a DS7447 or DS7445 keypad DS7447 DS7445 Armed Status Power Fire Armed Status Power Fire Perimeter

More information

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5 Construction Standards Page 1 of 5.1 General Description.1 The University requires that all new fire alarm system control panel, components, and devices, as required for the project, be Secutron 2900 Series

More information