Fiber Optic Patch Cord and Pigtails
|
|
- Branden Poole
- 5 years ago
- Views:
Transcription
1 Fiber Optic Patch Cord and Pigtails Description The optical fiber patch cords are fitted at both ends with same connector types or different connector types. Our fiber optic patch cords are ultra reliable devices featuring low insertion loss and high return loss. The patch cords come with your choice of simplex or duplex cable configurations and various cords of style. Application High Speed Digital System Cards DWDM Application Optical communication systems Optical instrument Features FC/SC/LC /ST/MTRJ/MU/E2000/MPO/D4/DIN/SMA/FDDI/ESCON connector optional Comply with IEC, ITU-T, ETSI recommendations and Telcordia standards.. Low insertion loss:not more than 0.2dB for both APC and UPC High return loss: UPC>-55dB APC>-65dB All models of cables optional, all kinds of combinations Superior qualified standard PC/SPC/UPC/APC polishing 0.9mm.2.0mm.3.0mm and all diameter cable are available Single mode or multi modes Simplex/duplex patch cord available 100% optic test (insertion loss and return loss)
2 The bending radius: 25mm or less. The service life of the connector: more than 1000 mate/ demate cycles without any degradation of the transmission quality. Ambient temperature range from -40 o C to 80 o C and humidity up to 95% non-condensing. Construction and Material (Single Mode Fiber Cable) The optical fiber conforms to the requirement of ITU-T Recommendation G.652D. PARAMETER SPECIFICATION 1. Mode Field Diameter 8.6 to 9.5 μ m at 1310nm 2. Cladding diameter 125 μ m±1.0 μ m 3. Mode Field Concentricity Error Less than 0.6 μ m 4. Cladding non-circularity Less than 1% 5. Cable cut-off Wavelength ( λ cc) Less than 1260nm 6. Polarization mode dispersion(pmd) 0.2ps/km 7. Attenuation coefficient Less than 0.35dB/km at 1310nm Less than 0.35dB/km at 1383nm Less than 0.21dB/km at 1550nm Less than 0.23dB/km at 1625nm 8. Proof stress More than 0.69GPa 9. Maximum attenuation with macro Less than 0.10 db at 1550nm bending 100 turns 30mm radius Buffer: tight buffer and white color
3 Protective Member: made of polaramid (Kevlar) Sheath: Fire retardant sheath fire retardant sheath, yellow halogen-free, Smooth, colored uniformly and free of crack, hole and stain. Item Dia. Of Buffered fiber Min. thickness of sheath Overall Dia Dimension(mm) ±0.2 CONNECTOR The structure and dimension of the ferrules are complying with the following standards: CONNECTOR TYPE APPLICABLE STANDARD 1. FC IEC ( ) Ed LC IEC ( ) Ed SC IEC ( ) Ed ST IEC ( ) Ed E2000 IEC ( ) Ed. 1.0 The ferrule end face geometry complies with Telcordia GR-326 specifications. The ferrule specifications: PARAMETER Ferrule type Nominal ferrule diameter(fc, SC and E2000) Nominal ferrule diameter (LC) Fiber concentricity SPECIFICATION Fully zirconia-ceramic 2.5mm±0.5μ m 1.25mm±0.5μ m 1μ m The ferrule for patch cord, pigtails are made of fully zirconia ceramic material. Dust caps are preinstalled onto the connector ends to prevent contamination. It is preferable if the dust cap is an integral part of the fiber cord.
4 The external parts for FC types shall be made of nickel-plated brass. For SC, LC and E2000 types, it shall be plastic body bulkhead types. Mechanical and Environment Performance for Patch Cords and Pigtails Test Type Test Condition Test Method Requirement Appearance Exam the producdt with naked eye Tensile Strength Strength of coupling mechanism Torsion Strippability Patch cord max. Tensile strength: 70N Pigtail max. Tensile strength: 5N Rate: 0N Cin 15s Point of application: 500mm from plug Duration: 60s Patch cord max. Tensile strength: 40N Pigtail max. Tensile strength: 5N Rate: 0N - in 15s Point of application: 500mm from plug Duration: 60s Max load patch cord: 15N Max load pigtail: 2N Cable clamp distance: 200mm for the tip Torsion: +180 / -180 Cycles: 25 Strip the outer jacket out of the patch cord in one action Strip tight buffer tube out of f iber in one action Use commercial available tools IEC IEC IEC No deformation, crack, scratch, flaw, stain, looseness and burr. 2. Change of 1)Insersion loss is less than 0.2dB 2)Return loss is less than 2dB 3)Appearance 1.Minimum length outer jacket shall be stripped: 1m 2. Minimum length of tight buffer tube shall be stripped: 25mm
5 TECHNICAL DATA OF PATCH CORDS FC Patch Cord (Single Mode) Item Technical Data PC UPC APC Insert Loss 0.3dB 0.2dB 0.2dB Return Loss 45dB 55dB 65dB Exchange Ability <0.2dB <0.2dB <0.2dB Repeatability <0.1dB <0.1dB <0.1dB Mating Durability 1000 times 1000 times 1000 times Working Humidity Up to 95% Up to 95% Up to 95% Temperature Range -40 ~ ~ ~+80 LC Patch Cord(Single Mode) Item Technical Data PC SPC UPC APC Insert Loss 0.3dB 0.3dB 0.2dB 0.2dB Return Loss 45dB 50dB 55dB 65dB Exchange Ability <0.2dB <0.2dB <0.2dB <0.2dB Repeatability <0.1dB <0.1dB <0.1dB <0.1dB Mating Durability 1000 times 1000 times 1000 times 1000 times
6 Working Humidity Up to 95% Up to 95% Up to 95% Up to 95% Temperature Range -40 ~ ~ ~ ~+80 SC Patch Cord(Single Mode) Item Technical Data PC SPC UPC APC Insert Loss 0.3dB 0.3dB 0.2dB 0.2dB Return Loss 45dB 50dB 55dB 65dB Exchange Ability <0.2dB <0.2dB <0.2dB <0.2dB Repeatability <0.1dB <0.1dB <0.1dB <0.1dB Mating Durability 1000 times 1000 times 1000 times 1000 times Working Humidity Up to 95% Up to 95% Up to 95% Up to 95% Temperature Range -40 ~ ~ ~ ~+80 E-2000 Patch Cord(Single Mode) Item Technical Data E2000/PC E2000/UPC E2000/APC Insert Loss 0.3dB 0.2dB 0.2dB Return Loss 40dB 55dB 65dB Repeatability <0.1dB <0.1dB <0.1dB Exchange Ability <0.2dB <0.2dB <0.2dB Fiber Type 9/125μm Cable Diameter φ0.9mm, φ2.0mm, φ3.0
7 Working Humidity Up to 95% Up to 95% Up to 95% Working Temperature -20 ~ ~ ~+80 MTRJ Patch Cord (Single Mode and Multi Mode) Item Single Mode Multi Mode PC UPC PC UPC Insert Loss 0.4dB 0.4dB 0.5dB 0.5dB Return Loss 40dB 45dB 25dB 45dB Repeatability <0.2dB <0.2dB <0.2dB <0.2dB Exchange Ability <0.1dB <0.1dB <0.1dB <0.1dB Working Humidity Up to 95% Up to 95% Up to 95% Up to 95% Storage Temperature -40 ~ ~ ~ ~+80 Operating Temperature -40 ~ ~ ~ ~+80
8 Production Line for Patch Cord Monthly Product Capacity: pieces of fiber optic patch cords Annual Product Capacity: pieces of fiber optic patch cords MAIN MANUFACTURING EQUIPMENT LIST Serial No. DESCRIPTION TYPE QTY (SET) 1 Curing Table 24 F 30 2 Digital Display Thermometer XMT 30 3 Grinding Machine MCD Grinding Machine SFP Air Press V-0.6/8 6 6 Supersonic Washing Machine BG06C 5 7 Auto Fiber Cable Cutting Machine XINZE-X25 6 MAIN TEST FACILITIES LIST SERIAL NO. DESCRIPTION TYPE QTY(SET) 1 JDS Reflection Coefficient Meter RX Electronic Microscope 400 M 10 3 Temperature Test Chamber WD Oven RLH 10 5 Mechanical Tensile Testing Machine LJ Bending/Rotation Tester JZT/Z-1 2
9 CERTIFICATE FOR PRODUCT CERTIFICATION
10 Certificate for Product Certification Certification No: R2M TLC Certificate for Products Certification This is to certify Name and Address of Certificated Enterprise Sichuan Tianyi Comheart Opto-electronics Co., Ltd Registration Address: No. 210 West Street, Jinyuan Town, Dayi County, Chengdu, Sichuan, China Production Address: No. 198 Industry Avenue, Dayi County, Chendu, Certificated Product FC/PC FIBER OPTICAL PATCH CORDS Standard of Certification YD/T Above products conform to the requirement of telecommunication cable/optical fiber cable equipment certification standards; certification mode is type test + primary factory test + supervision after obtaining the certificate Date of Issuance: March 2, 2010 Date of Expiry: March 1,, 2013 TL Certification Center Director of Center: Song Busi * Note: Related product details about conforming to the standards are shown in attachment. The validity of this certification also depends on the annual regular supervision conclusion specified in attachment, or it can be obtained by assessing
11 CANB 030-P
12 Certificate for Product Certification Certification No: R2M TLC Certificate for Products Certification This is to certify Name and Address of Certificated Enterprise Sichuan Tianyi Comheart Opto-electronics Co., Ltd Registration Address: No. 210 West Street, Jinyuan Town, Dayi County, Chengdu, Sichuan, China Production Address: No. 198 Industry Avenue, Dayi County, Chendu, Certificated Product SC/PC FIBER OPTICAL PATCH CORDS Standard of Certification YD/T Above products conform to the requirement of telecommunication cable/optical fiber cable equipment certification standards; certification mode is type test + primary factory test + supervision after obtaining the certificate Date of Issuance: March 2, 2010 Date of Expiry: March 1,, 2013 TL Certification Center Director of Center: Song Busi * Note: Related product details about conforming to the standards are shown in attachment. The validity of this certification also depends on the annual regular supervision conclusion specified in attachment, or it can be obtained by assessing
13 CANB 030-P
14 Certificate for Product Certification Certification No: R1M TLC Certificate for Products Certification This is to certify Name and Address of Certificated Enterprise Sichuan Tianyi Comheart Opto-electronics Co., Ltd Registration Address: No. 210 West Street, Jinyuan Town, Dayi County, Chengdu, Sichuan, China Production Address: No. 198 Industry Avenue, Dayi County, Chendu, Certificated Product LC/PC FIBER OPTICAL PATCH CORDS Standard of Certification YD/T Above products conform to the requirement of telecommunication cable/optical fiber cable equipment certification standards; certification mode is type test + primary factory test + supervision after obtaining the certificate Date of Issuance: March 2, 2010 Date of Expiry: March 1,, 2013 TL Certification Center Director of Center: Song Busi * Note: Related product details about conforming to the standards are shown in attachment. The validity of this certification also depends on the annual regular supervision conclusion specified in attachment, or it can be obtained by assessing
15 CANB 030-P
16 Certificate for Product Certification Certification No: R2M TLC Certificate for Products Certification This is to certify Name and Address of Certificated Enterprise Sichuan Tianyi Comheart Opto-electronics Co., Ltd Registration Address: No. 210 West Street, Jinyuan Town, Dayi County, Chengdu, Sichuan, China Production Address: No. 198 Industry Avenue, Dayi County, Chendu, Certificated Product FC/APC FIBER OPTICAL PATCH CORDS Standard of Certification YD/T Above products conform to the requirement of telecommunication cable/optical fiber cable equipment certification standards; certification mode is type test + primary factory test + supervision after obtaining the certificate 1000 Date of Issuance: March 2, 2010 Date of Expiry: March 1,, 2013 TL Certification Center Director of Center: Song Busi * Note: Related product details about conforming to the standards are shown in attachment. The validity of this certification also depends on the annual regular supervision conclusion specified in attachment, or it can be obtained by assessing CANB 030-P
Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003
Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber PureGuide SM Optical Fiber, TIA Type IVd Issued: November 2003 78 Alexander Drive, Research Triangle Park, NC 27709 Phone
More informationFibre Specification Standards
Fibre Specification Standards User Manual The most important thing we build is trust Cobham Wireless - Coverage Table of Contents 1. Single-mode Fibre to ITU-T Recommendation G.652 3 2. SC/APC Mated Pair
More informationAttenuators. Fiber Optic Products Catalog. Singlemode Build Out Attenuators. Product Facts. Applications. Customizable Features. Available Collateral
Attenuators Build Out Attenuators Product Facts A range of fixed attenuation values. Standard values of 1 through 20 and 25dB UPC and APC offer Excellent Return Loss LC, SC, FC, ST, and D4 styles Attenuation
More informationSumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber
Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber PureGuide -LA SM Optical Fiber, TIA Type IVd ITU G.655 C and D Compliant Issued:
More informationFiberExpress Solutions
7.2.1-A 7.2.1-B 7.2.1-C 7.2.1-D Simplex Patch Cord Duplex Patch Cord Hybrid Patch Cord Single-ended (pigtails) AX200057 Patch Cord Multimode SC Duplex DESCRIPTION FiberExpress Simplex and Duplex Patch
More informationDuct Cable GYTS-144B1.3
Optical Fibre Cable Technical Specification Duct Cable GYTS-144B1.3 Xcom Ltd All rights reserved 1. Scope This Specification covers the design requirements and performance standard for the supply of optical
More information--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T
Translated English of Chinese Standard: YD/T1447-2013 www.chinesestandard.net Sales@ChineseStandard.net COMMUNICATION INDUSTRY STANDARD OF THE PEOPLE S REPUBLIC OF CHINA YD ICS 33.180.10 M 33 Replacing
More informationData sheet OpDAT universal cable 1x24 OM4 - bend insensitive
Illustrations Principle diagram Page 1/7 Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or stranded loose tube bend insensitive fiber
More informationQualification Test Report LC Duplex Adapter For LC Cutouts
Qualification Test Report LC Duplex Adapter For LC Cutouts 501-683 09Mar09 Rev B 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LC Duplex Adapters for LC Cutouts, to determine their
More informationOptical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3
VersionGYTA-72B1.3 Optical Fibre Cable Technical Specification Duct Cable GYTA-72B1.3 Yangtze Optical Fibre and Cable Joint Stock Limited Company All rights reserved www.yofc.com All Rights Reserved Copyright
More informationApr06 Rev A
Qualification Test Report LC, Multimode, One-Piece Housing, Fiber Optic Connector 501-628 03Apr06 Rev A 1. INTRODUCTION 1.1. Purpose 1.2. Scope Testing was performed on Tyco Electronics LC multimode, one-piece
More information2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK
PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway
More informationFiretuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red
OFC-UT-CST Fire resistant Armoured Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU
More informationData sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1
Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors
More informationUser Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)
User s Fiberprime, Inc. Portable 4-Channel Laser Source Instrument www.fiberprime.com Tel: 1-613-5964030 Email: info@fiberprime.com Fax: 1-613-8289398 Portable 4-Channel Laser Source Instrument in Small
More informationQualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)
Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) 501-586 26Feb09 Rev F 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LightCrimp*
More informationITU-T L.404. Field mountable single-mode optical fibre connectors
I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T L.404 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (08/2017) SERIES L: ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY
More informationData sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive
Page 1/8 Illustrations Principle diagram See enlarged drawings at the end of document Product specification mini-breakout installation cable U-VQ(ZN)H laser-optimized, bend insensitive fiber UV-resistant,
More informationEnsuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications
Ensuring Cabling Performance in the Customer-Owned Outside Plant Keith Foord Product Manager Greenlee Communications Introduction: Outside plant fiber networks require low reflectance terminations for
More informationHELKAMA. Optical Fibre Cables
1 Contents Optical fibres and their characteristics Cable constructions Cable tests Installation, jointing and terminating Manufacturing (pictures) 2 Multimode Fibre (GK) Attenuation and Bandwidth Fibre
More informationHands-On Fiber Optics ISP/OSP - Advanced Combo- Tech
Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech Course Description This Hands-On 3-day course has been customized to provide technicians with a practical understanding of fiber optic theory and fiber
More informationBest Practice Briefing
Best Practice Briefing Fiber Optic Connector Handling, Inspection, andcleaning microwave photonic systems Expand Your RF Horizons Briefing Overview Personnel Safety & Best Practices Insertion Loss (IL)
More informationMT-RJ Optical Fiber System Field Testing
MT-RJ Optical Fiber System Field Testing Table of Contents INTRODUCTION... 3 TEST JUMPERS... 4 LAUNCH CONDITIONS... 4 MT-RJ TEST KITS... 5 MT-RJ SYSTEM TESTING: Fixed transmit and receive (SC or ST-style)
More informationFiber Optic Distribution Cables (6-144 Fibers)
900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: AMP NETCONNECT distribution cables are
More informationINTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
INTERNATIONAL TELECOMMUNICATION UNION ITU-T L.36 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (10/98) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
More informationOWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015
Laser OWL Series Operations Guide Singlemode Light Sources OWL Optical Wavelength Laboratories Operations Guide Laser OWL and Laser OWL HP Singlemode Light Sources Date: October 1, 015 Version.5 Optical
More informationConnections You Can Count On.
Connections You Can Count On. XPRESS ULTRA FIBER CONNECTOR PRODUCT GUIDE - CLEANING & INSPECTION - TESTING AND TROUBLE SHOOTING - XPRESS ULTRA FIBER CONNECTORS - INSTALLATION KITS Connections You Can Count
More informationEnsuring Cabling Performance in the Customer-Owned Outside Plant
Ensuring Cabling Performance in the Customer-Owned Outside Plant Needs to be able to qualify the installation to validate bandwidth requirements are met Future high bandwidth applications Future Proof
More informationThe True Value of Connector Inspection: New Challenges and Best Practices
The True Value of Connector Inspection: New Challenges and Best Practices Vincent Racine Product Line Manager August 2011 1 Table of contents 1 Best Practices 2 Connector Inspection Tools 3 Connector Inspection
More information13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION
13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION This specification is property of SEC and subject to change or modification
More informationDNVGL-CP-0402 Edition February 2016
CLASS PROGRAMME Type approval DNVGL-CP-0402 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationHands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing
Hands-On Splicing, Termination & Testing BICSI CECs This course has been approved for CEC credits by BICSI. Please read below for a breakdown of the credits that we offer for this course. For more information
More informationVTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links
VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links TB Number 004 This bulletin is supplied for information only and is intended to provide
More informationField Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks
Field Testing and Troubleshooting of PON LAN Networks per IEC 61280-4 Jim Davis Regional Marketing Engineer Fluke Networks Agenda Inspection and Cleaning APC vs UPC PON basics Wavelengths Architecture
More informationAccelerating NBN fiber testing. Tom Ronan Marketing Lead Fiber Optics Melbourne
Accelerating NBN fiber testing and workforce Performance. Tom Ronan Marketing Lead Fiber Optics Melbourne Agenda Network Elements and Parameters Distributed Fiber Network (DFN) Construction Network Activation
More informationMADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments
MADE FOR THE TRADE! professional FIBER OPTIC XL fibertools Series instruments XL fibertools Series Instruments Designed for Fiber Optic Cable Testing. The XL fibertools are designed for the professional
More informationTE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET
Optic Backbone Distribution Cables 900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: TE
More informationIndustrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers
Features and Benefits Corrugated armor Mechanical protection Low-smoke/zero-halogen (LSZH ) sheath Key life-safety benefit Meets cyclic impact and chemical resistance test Superior performance Tray-rated
More informationSTANDARD CONFORMANCE
STANDARD CONFORMANCE IEC 60331-11, Tests for electric cables under fire conditions- Circuit integrity- Fire alone at a flame temperature of at least 750C IEC 60331-21, Tests for electric cables under fire
More informationFiber Optic Products Catalog
Fiber Optic Products Catalog No epoxy, no polish, no crimp Two fibers in one ferrule MT-RJ Patch Panel Jack packages include: 6 MT-RJ Jacks 2 Actuator Tools 1 Fiber Guide 1 Icon Wheel Bend Limiting Boots
More informationCore Alignment All In One Fusion Splicer
Economical Solution for Integrated Fiber Preparation Tool Demand. Core Alignment All In One Fusion Splicer Single Optical Fiber Fusion Splicer US Patent /9 2,09 The Revolution of a Splicer Integrated to
More informationSpecial Provision No. 683S28 December 2017
FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE - Item No. FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE (TEMPORARY) - Item No. Special Provision No. 683S28 December 2017 1. SCOPE
More informationCHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES
THE CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES 17th September 2002 Botanical Gardens Birmingham The Way We Were 1GbE and 10GbE OF Categories Channel Design Cleaning SFF Connecting Hardware Testing
More informationGUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.
GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection 07-07-05 v3.0 Ordering Information Belden Part Numbers Fibre Description
More informationMultipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24
Features and Benefits Laminated swelling glass yarns Improved rodent resistance and longitudinal water protection UV and microbe resistant Can be directly buried or installed in ducts Metal-free cable
More informationJan07 Rev B
Qualification Test Report 501-545 05Jan07 Rev B MT-RJ Patch Panel and Outlet Jacks (Standard, XG, SECURE and SECURE XG) 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics MT-RJ Jack,
More informationMADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments
MADE FOR THE TRADE! FIBER OPTIC professional XL fibertools Series instruments XL fibertools Series Instruments Designed for Fiber Optic Cable Testing. The XL fibertools are designed for the professional
More informationBasic Professional Fiber Optic Installation
Basic Professional Fiber Optic Installation QUICK SUMMARY Length: 32 hours; or 40 hours with Fiber Optic Association CFOT certification Hands-on Activities: 40 activities, 70-75 % Text/Field Reference:
More informationPureGain TM 2600 Variable Gain EDFA for Metropolitan Networks
FEATURES Variable Gain Amplifier with or without Mid-Stage Fully Integrated Control Electronics with State-of-the-Art Transient Suppression Control Three Standard Configurations Mk I: 17 dbm VGA (Variable
More informationFiretuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red
Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU VERITAS December 2014 OFC-UT-CST
More informationThe Rise of Tier 2 Testing
The Rise of Tier 2 Testing Why enterprises today demand better visibility into their fiber infrastructure Unprecedented demand for more bandwidth, faster network speeds, lower latency, and improved data
More informationGR-326-CORE Singlemode Optical Connectors and Jumper Assemblies
Preface...Preface 1 1. Introduction... 1 1 1.1 Purpose and Scope... 1 1 1.2 Target Audience... 1 2 1.3 Structure and Use of This Document...1 2 1.4 Changes from Issue 2 of GR-326-CORE... 1 3 1.5 Requirements
More informationOptical Multitester 500 450 OTDR EMEA & APac Edition Issue 1 Page 1 of 10 Description The 450 OTDR is a PC based state-ofthe-art OTDR designed for field applications. It is a dedicated OTDR which offers
More informationFibre (TIA) Field Test Specification
This document has been prepared to aid consultants or engineers in developing contractual specifications covering the testing of duplex fibre optic cabling installations. It is offered as a general guide.
More informationProduct Specification Qualification Test Report
PS 88 / DMI PC SM / 6/5 DIAMOND Test & Calibration Laboratory STS 333 / SCS 11 Product Specification Qualification Test Report DMI PC SM DIAMOND SA Via dei Patrizi 5 CH-6616 LOSONE Tel. +41 91 785 45 45
More informationOptical Return Loss Measurement by Gregory Lietaert, Product Manager
White Paper Optical Return Loss Measurement by Gregory Lietaert, Product Manager Introduction With the increasing frequency of high-speed transmission systems and DWDM deployment, optical return loss (ORL)
More informationFiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know. David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO
Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO Workshop format The Workshop is going to start with three short lecture style power
More informationA Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification
A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing Vol. 2 Tier 2 Certification Notice Copyright Every effort was made to ensure that the information in this document
More informationoutdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free
GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection 05-04-8 v0.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4
More informationM700-Series Multifunction OTDR
M700-Series Multifunction OTDR Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks Test Modes Full Auto OTDR Normal (point-to-point) fiber cable construction testing and fault location
More informationApplication Engineering Note. Importance of Jacket Crimping
Importance of Jacket Crimping SENKO Product Datasheet 2003 by SENKO Advanced Components All Rights Reserved Date: 01/11/2018 ISO 9001: 2000 Purpose Crimping or rather crimping strength is essential to
More informationLSH (E 2000 ) High performance. High reliability. High safety. High flexibility
E-2000 is a high performance connector which meets the highest standards y excellence in design and manufacturing processes. Only high quality and high precision materials are used to guarantee connections
More informationGCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.
GCRG Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection 05-05-7 v7.0 Ordering Information Belden Part Numbers Fibre Description / count 4 8 8 4 30 36 6.5/5-OM GCRG04
More informationA Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification
A Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing Vol. 2 Tier 2 Certification A Quick Start Guide to Fiber-to-the-Antenna enna (FTTA) Installation and Maintenance Testing
More informationProduct Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)
Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming) 02Oct08 Rev A 1. SCOPE 1.1. Content This specification, based on IEC 61753-1 Edition 1.0 tests for Category E (Extreme Environment),
More informationClearlite Photonic Fibers
Clearlite Photonic Fibers Fiber Name Operating Wavelength MFD at Operating Wavelength Beat Length at Operating WL Clad/Coating Diameter Order by Part Number TruePhase 980 Micro TruePhase 980 400 TruePhase
More informationRLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507
RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable Reference Guide MD-019 2014A 0507 RLH Industries, Inc. Copyright 2013 RLH Industries, Inc. All rights reserved. No part of this document may
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationAS/NZS ISO/IEC :2012
AS/NZS ISO/IEC 14763.3:2012 (ISO/IEC 14763-3:2011, MOD) Australian/New Zealand Standard Telecommunications installations Implementation and operation of customer premises cabling Part 3: Testing of optical
More informationVIEW500 USER-FRIENDLY STANDARD OTDR
USER-FRIENDLY STANDARD OTDR SOLA (Smart Optical Link Analyzer) 7 Touch Screen with Smart GUI 8GB Internal Storage with Internal SD Card & External USB Memory Built-In VFL, Light Source and OPM Fast Booting
More informationM310 Data Center OTDR
Designed for Data Center Testing, Troubleshooting and Documentation Features Event Dead Zone 0.8 m Attenuation Dead Zone
More informationINTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD
INTERIM EUROPEAN I-ETS 300 644 TELECOMMUNICATION June 1997 STANDARD Source: ETSI TC-TM Reference: DI/TM-01021 ICS: 33.020 Key words: Fibre, cable, optical, transmission Transmission and Multiplexing (TM);
More informationVIEW500 FASTEST STANDARD OTDR
FASTEST STANDARD OTDR SOLA, Simplify The OTDR Test Process 7 Touch Screen with Smart GUI 8GB Internal Storage with Internal SD Card & External USB Memory Built-In VFL, Light Source and OPM Fast Booting
More informationHands-On CAT 5/6 & Fiber Optic Installer
Hands-On BICSI CECs This course has been approved for CEC credits by BICSI. Please read below for a breakdown of the credits that we offer for this course. For more information regarding BICSI please visit
More informationENCIRCLED FLUX (EF) TEST SOLUTIONS SPSB-EF LAUNCH MODE CONDITIONER AND FLS-600-NS1548 LIGHT SOURCE DESIGNED FOR CONTROLLED MULTIMODE LOSS TESTING
ENCIRCLED FLUX (EF) TEST SOLUTIONS SPSB-EF LAUNCH MODE CONDITIONER AND FLS-600-NS1548 LIGHT SOURCE DESIGNED FOR CONTROLLED MULTIMODE LOSS TESTING Tier-1/2 solutions with controlled source launch conditions
More informationM210 Multifunction Micro OTDR
Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks Features 30 db dynamic range single-mode 16-hour battery life Remote display capable Touch and Test intuitive user interface New
More informationFiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling
Hands-On Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling Certification Course Description This Hands-On course is customized to give Technicians the confidence and skills to maintain Fiber
More informationITU-T L.12. Optical fibre joints SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
INTERNATIONAL TELECOMMUNICATION UNION ITU-T L.12 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (05/2000) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
More informationTELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS
TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS TKF TECHNOLOGICAL LEADERSHIP IN CONNECTIVITY SOLUTIONS Since its establishment in 90 TKF developed from a cable producer to a leading
More informationM210 Multifunction Micro OTDR
Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks Features 30 db dynamic range single-mode 16-hour battery life Remote display capable Touch and Test intuitive user interface New
More informationMINI2 MOST ACCURATE COMPACT OTDR
MOST ACCURATE COMPACT OTDR SOLA, Simplify The OTDR Test Process 5 Touch Screen with Smart GUI 8GB Internal Storage with Internal SD Card & External USB Memory Built-In VFL and Light Source Fast Booting
More information/Mar/2014 Rev A
Qualification Test Report 501-93038 21/Mar/2014 Rev A MPOptimate FO Microcassette 12 fiber MPO-12xLC/PC 1. INTRODUCTION 1.1 Purpose Tests performed on MPOptimate FO Microcassette 12 fiber MPO-12xLC/PC,
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO/IEC 14763-3 First edition 2006-06 Information technology Implementation and operation of customer premises cabling Part 3: Testing of optical fibre cabling Reference number ISO/IEC
More informationNoyes OFL 250B Specs Provided by
Noyes OFL 250B Specs Provided by www.aaatesters.com OFL 250 Handheld OTDR The Noyes OFL 250 from AFL Telecommunications is a single-mode OTDR with an integrated Optical Power Meter (OPM), Source (OLS),
More informationSpecification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.
Specification No.CSC-131/R-1/DH//UH/P&D/2016-17 Technical Specifications for 24 Fiber/48 Fiber Unarmoured Underground Fibre Optic Cabling Issue Month:June-2016 (CSC Amendment date 14.06.2016) Common Specification
More informationM310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)
Designed for Enterprise Network Testing, Troubleshooting and Documentation Features Integrated Optical Power Meter and Visual Fault Locator Short dead zones provide testing of closely spaced events Industry
More informationWhite Paper: Fiber Contamination, Cleaning and Inspection. Introduction.
White Paper: Fiber Contamination, Cleaning and Inspection. Introduction. Despite industry best practice of inspecting and cleaning fiber optic endfaces, contaminated connections remain the number one cause
More informationTest Report for Senko Advanced Components, Report No RES3005 February 22, Test Report. Senko Advanced Components
Test Report Report No. Client: Address: RES3005 Senko Advanced Components 225 Cedar Hill Street Marlboro, MA 01752 Phone: 508-481-9999 Product Tested: Q-XP MSOC 900m Test Dates: April 2010 October 2010
More informationAcceptance Requirements. Fibre Optic Systems. Revised 12/2017. December 5th, Alexander Kölbel
December 5th, 2017 Acceptance Requirements Fibre Optic Systems Revised 12/2017 Alexander Kölbel +49 6190 8880-40 alexander.koelbel@datwyler.com Dätwyler Cables GmbH, Auf der Roos 4-12, 65795 Hattersheim,
More informationFIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.
FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No. Special Provision No. 683S01 December 2017 1. SCOPE This Special Provision covers
More informationFujikura-70S Single Fibre Fusion Splicer
Fujikura- Single Fibre Fusion Splicer Features Core-to Core alignment, Dual Axis observation system. World s quickest splicing 6sec. / tube-heating 9sec. Minimal manual operation. Splice in 4 steps. Multi-functional
More informationWhite Paper Fiber optic connections: check and clean first, then connect!
White Paper Fiber optic connections: check and clean first, then connect! How installers ensure the quality of their work Fiber optic connections: check and clean first, then connect! How installers ensure
More informationOPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx
fibrewave About Us Prysmian is a global market leader in optical cables, supplying a major part of the world s optical cable needs. With a strong heritage of highly advanced R&D, Prysmian is at the leading
More information4120 Fire Alarm Network Reference
4120 Fire Alarm Network Reference Features Autocall 4120 Fire Alarm Network communications are available for wired or fiber optic connections Wired communications are available on Network Interface Cards
More informationOPTICAL FIBER JOINTS & CONNECTIONS
OPTICAL FIBER JOINTS & CONNECTIONS Dr. BC Choudhary NITTTR, Sector-26, Chandigarh. Basic Fiber Optic Link Transmitter Connector Cable Splice Cable Receiver OPTICAL FIBER JOINTS Technical requirement for
More informationQualification Test Report. AMP-TWIST Series Jacks for Class EA systems
Qualification Test Report 501-93032 14/April/2011 Rev A AMP-TWIST Series Jacks for Class EA systems 1. INTRODUCTION 1.1 Purpose Qualification testing on AMP-TWIST* Series Jacks for Class E A Systems, to
More informationA. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.
3.4 TESTING OF FIBER OPTICS CABLING A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing. B. General: In the event
More informationFibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager
Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC Philip C Longhurst Corporate Fibre Optic R & D Manager Outline CENELEC TC86BXA work programme IEC SC86B WG 6 and
More informationDWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series
MTP-200-D100 Hand-held High Performance OTDR DWDM OTDR with Tunable Laser Series Multi-Function and High Performance OTDR Testing 96 C-band wavelengths Dynamic range up to 38dB Short zone: EDZ 1m, ADZ
More informationM310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)
Designed for Enterprise Network Testing, Troubleshooting and Documentation Features Industry leading TruEvent analysis Short dead zones provide precise testing of closely spaced events Front Panel and
More information